Dell OpenManage Server Administrator Managed Node for Fluid Cache for DAS SNMP Reference Guide

book.book Page 1 Wednesday, March 6, 2013 12:37 AM
Dell OpenManage
Server Administrator
SNMP Reference Guide
Version 7.1.2
book.book Page 2 Wednesday, March 6, 2013 12:37 AM
Notes and Cautions
NOTE: A NOTE indicates important information that helps you make better use of
your computer.
A CAUTION indicates potential damage to hardware or loss of data if instructions
are not followed.
__________________
Information in this publication is subject to change without notice.
© 2013 Dell Inc. All rights reserved.
Reproduction of these materials whatsoever without the written permission of Dell Inc. is strictly
forbidden.
Trademarks used in this text: Dell™, the DELL™ logo, PowerEdge™, PowerVault™, and
OpenManage™ are trademarks of Dell Inc. Microsoft® and Windows® are either trademarks or
registered trademarks of Microsoft Corporation in the United States and/or other countries. Intel®,
Itanium®, Pentium®, Atom®, and Celeron® are registered trademarks, and MMX™, Xeon™, and
Core™ are trademarks of Intel Corporation in the United States and/or other countries. VESA® is a
registered trademark of the Video Electronics Standards Association. AMD™, AMD Athlon™, AMD
Opteron™, AMD Sempron™, AMD Turion™, AMD Phenom™, and AMD Duron™ are trademarks
of Advanced Micro Devices, Inc. VIA C7™ and VIA Eden™ are either trademarks or registered
trademarks of VIA Technology, Inc. Crusoe™ and Efficeon™ are trademarks of Transmeta
Corporation in the USA and other countries.
Other trademarks and trade names may be used in this document to refer to either the entities claiming
the marks and names or their products. Dell Inc. disclaims any proprietary interest in trademarks and
trade names other than its own.
2013 - 03
book.book Page 3 Wednesday, March 6, 2013 12:37 AM
Contents
1
Introduction .
. . . . . . . . . . . . . . . . . . . . . .
What’s New in This Release
. . . . . . . . . . . . . .
17
. . . . . . . . .
17
. . . . . . . . . . . . . . . . . . . .
17
Storage Management Group MIB
iDRAC7 MIB
17
Supported SNMP Versions
. . . . . . . . . . . . . . .
Introduction to the SNMP Reference Guide
. . . . . .
18
18
Server Administrator Instrumentation MIB
. . . .
19
Server Administrator Remote Access MIB
. . . .
21
Server Administrator Baseboard Management
Controller, ASF MIB . . . . . . . . . . . . . .
. .
22
Server Administrator Field Replaceable Unit MIB .
22
Server Administrator Storage Management MIB
.
23
Server Administrator Change Management MIB
.
24
Dell Remote Access Controller Out-of-Band MIB
.
24
. . . . .
25
. . . . . . . . . . . . .
26
How This Guide Defines Technical Terms
SNMP Basic Terminology
Frequently Used Terms in Variable Names
Tables
. . . .
29
. . . . . . . . . . . . . . . . . . . . . . .
30
Section Organization
. . . . . . . . . . . . . . . .
Other Documents You May Need
. . . . . . . . .
Introduction to the Server Administrator
SNMP Subagent . . . . . . . . . . . . .
. . . . . . . .
SNMP Management Information Base
Object Identifiers . . . . . . . . . . . .
SNMP Security .
33
34
34
. . . . . .
36
. . . . . . . . . . . . . . . . . .
37
Management Actions
. . . . . . . . . . . . . . .
Contents
38
3
book.book Page 4 Wednesday, March 6, 2013 12:37 AM
SNMP Traps
2
3
. . . . . . . . . . . . . . . . . . . .
Instrumentation MIB Version Group
. . . .
41
Management Information Base Major Version Number
41
Management Information Base Minor Version Number
42
Management Information Base Maintenance
Version Number . . . . . . . . . . . . . . . .
42
. . . . .
Systems Management Software Group .
Systems Management Software
.
43
. . . . . . . . . . . .
43
. . .
47
System State Group .
. . . . . . . . . . . . . . . .
49
System State Group Table
. . . . . . . . . . . . . . . .
49
System State Table
. . . . . . . . . . . . . . . . .
49
System State Table
. . . . . . . . . . . . . . . . .
51
Systems Management Software Variable Values
4
5
Chassis Information Group
. . . . . . . . . . .
71
Chassis Information Group Tables
. . . . . . . . . . .
71
. . . . . . . . . . . . .
71
. . . . . . . . . . . . . . . . . . . . .
84
Chassis Information Table
UUID Table
POST Log Table .
Event Log Table
. . . . . . . . . . . . . . . . . .
86
. . . . . . . . . . . . . . . . . . .
88
System BIOS Table
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
98
Intrusion Table
. . . . . . . . . . . . . . . . . . .
101
. . . . . . . . . . . . . . . . . .
Chassis Information Group Variable Values
Contents
91
Firmware Table
Baseboard Table
4
38
. . . . . .
103
108
book.book Page 5 Wednesday, March 6, 2013 12:37 AM
6
Operating System Group
. . . . . . . . . . . .
Operating System Memory Table
7
System Resource Group
131
. . . . . . . . . . .
131
. . . . . . . . . .
133
System Resource Owner Table
. .
136
System Resource Memory Table .
. . . . . . . . .
139
System Resource Interrupt Table
. . . . . . . . .
142
System Resource Input/Output (I/O) Port Table
System Resource Direct Memory Access
(DMA) Table . . . . . . . . . . . . . . .
System Resource Group Variable Values
Power Group
. . . . .
145
. . . . . . . .
148
. . . . . . . . . . . . . . . . . . . . .
153
Power Group Tables .
. . . . . . . . . . . . . . . . . .
153
Power Unit Table
. . . . . . . . . . . . . . . . . .
153
Power Supply Table
. . . . . . . . . . . . . . . .
156
Voltage Probe Table
. . . . . . . . . . . . . . . .
160
Amperage Probe Table .
. . . . . . . . . . . . . .
165
AC Power Switch Table
. . . . . . . . . . . . . .
171
. . . . . . . . . . . . . . .
173
. . . . . . . . . . . . . . . . . . . .
176
AC Power Cord Table
Battery Table
Power Usage Table
. . . . . . . . . . . . . . . .
178
Power Profile Table
. . . . . . . . . . . . . . . .
184
Power Group Variable Values .
9
131
. . . . . . . . . . . . .
System Resource Map Table .
8
125
. . . . . . . . .
. . . . . . . . . . . .
System Resource Group Tables
123
Thermal Group
. . . . . . . . . . . . . . . . . . .
Thermal Group Tables
187
. . . . . . . . . . . . .
201
. . . . . . . . . . . . . . . . . .
Cooling Unit Table
. . . . . . . . . . . . . . . . .
Contents
201
201
5
book.book Page 6 Wednesday, March 6, 2013 12:37 AM
Cooling Device Table
. . . . . . . . . . . . . . . .
Temperature Probe Table
Thermal Group Variable Values
10 User Security Group
. . . . . . . . . . . . .
209
. . . . . . . . . . . . .
215
. . . . . . . . . . . . . . .
User Security Group Table
User Security Table .
219
. . . . . . . . . . . . . . . .
219
Remote Flash BIOS Group Table
Remote Flash BIOS Table .
. . . . . . . . . . .
223
. . . . . . . . . . . . .
223
. . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
Pointing Port Table
. . . . . . . . . . . . . . . . .
229
229
229
. . . . . . . . . . . . . . . .
232
Processor Port Table
. . . . . . . . . . . . . . . .
235
Monitor Port Table
. . . . . . . . . . . . .
238
. . . . . . . . . . . . . . . . .
241
Small Computer System Interface (SCSI)
Port Table . . . . . . . . . . . . . . . . .
. . . . .
244
. . . . . . . . . . . . . . . . .
246
. . . . . . . . . . . . . . . . . .
250
Parallel Port Table
Serial Port Table
Universal Serial Bus (USB) Port Table
Port Group Variable Values
13 Device Group .
Device Tables
Contents
226
Keyboard Port Table
Memory Device Port Table
6
223
. . . . . . . . . . . .
Remote Flash BIOS Variable Values
Port Group Tables
219
. . . . . . . . . . . . . . .
11 Remote Flash BIOS Group
12 Port Group
204
. . . . . . .
254
. . . . . . . . . . . . . . .
257
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
263
263
book.book Page 7 Wednesday, March 6, 2013 12:37 AM
Pointing Device Table
264
. . . . . . . . . . . . . . .
Keyboard Device Table .
. . . . . . . . . . . . . .
266
Processor Device Table
. . . . . . . . . . . . . .
269
Processor Device Status Table
Cache Device Table
. . . . . . . . . .
277
. . . . . . . . . . . . . . . .
279
Memory Device Table
. . . . .
293
. . . . . . . . . . . . . . .
296
. . . . . . . . . . . . . . . . . .
299
Generic Device Table
PCI Device Table
PCI Device Configuration Space Table
Network Device Table
. . . . . .
302
. . . . . . . . . . . . . . .
305
Managed System Services Device Table
SD Card Unit Table
. . . . .
313
. . . . . . . . . . . . . . . . .
315
SD Card Device Table
System Slot Table
351
. . . . . . . . . . . . . . . . .
351
355
. . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . .
Physical Memory Tables
351
. . . . . . . . . . . . . . . .
System Slot Variable Values
15 Memory Group
322
. . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . .
System Slot Group Table
318
. . . . . . . . . . . . . . .
Device Group Variable Values
14 Slot Group
285
. . . . . . . . . . . . . . .
Memory Device Mapped Address Table .
365
. . . . . . . . . . . . . . . .
Physical Memory Array Table
. . . . . . . . . . .
Physical Memory Array Mapped Table
365
365
. . . . . .
370
. . . . . . .
373
Physical Memory Logging Table
. . . . . . . . . .
376
Redundant Memory Unit Table .
. . . . . . . . . .
378
. . . . . . . . . . .
381
. . . . . . . . . . . .
384
Physical Memory Configuration Table
Physical Memory Card Table .
Memory Group Variable Values .
Contents
7
book.book Page 8 Wednesday, March 6, 2013 12:37 AM
16 BIOS Setup Control Group .
BIOS Setup Control Group Tables
391
. . . . . . . . . . . . .
391
. . . . . . . . . . . . . . . . .
402
Parallel Port Control Table
. . . . . . . . . . . . .
404
. . . . . . . . . . . . . .
406
. . . . . . . . . . . . . . . . .
408
. . . . . . . . . . . . . . . . . .
410
Serial Port Control Table
USB Control Table
IDE Control Table
Diskette Control Table
. . . . . . . . . . . . . . .
Network Interface Control Table
BIOS Setting Table
414
. . . . . . . . . . . . . . . . .
417
. . . . . . . . . . . . . .
17 Local Response Agent Group
. . . . . . . . . . . . . . . .
LRA Global Settings Table
431
431
431
. . . . . . . . . . . . .
432
434
18 Cost of Ownership Group
Cost of Ownership Table
436
439
. . . . . . . . . . . .
439
. . . . . . . . . . . . . .
439
COO Service Contract Table
. . . . . . . . . . . .
450
. . . . . . . . . . . . .
452
. . . . . . . . . . . . . . . .
454
COO Cost Event Log Table
COO Warranty Table
. . . . . . . . .
. . . . . . . . . . .
Cost of Ownership Group Tables
COO Lease Information Table
. . . . . . . . . . .
456
COO Schedule Number Table
. . . . . . . . . . .
459
. . . . . . . . . . . . . . . . .
460
COO Options Table
COO Maintenance Table
Contents
420
. . . . . . . . . . . . . . . . . .
Local Response Agent Variable Values
8
. . . . . . . .
. . . . . . . . . . . . . . . . . . . .
LRA Global Settings
LRA Action Table
412
. . . . . . . . . .
BIOS Group Variable Values
LRA Group Tables
391
. . . . . . . . . . . .
BIOS Setup Control Table
SCSI Control Table
. . . . . . . . . .
. . . . . . . . . . . . . .
462
book.book Page 9 Wednesday, March 6, 2013 12:37 AM
COO Repair Table .
COO Support Information Table
COO Trouble Ticket Table
. . . . . . . . . .
466
. . . . . . . . . . . . .
468
Cost of Ownership Variable Values
19 Remote Access Group .
DRAC 4 and DRAC 5
470
. . . . . . . . . . .
. . . . . . . . . . . . .
473
473
. . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
473
. . . . . . . . . . . . . . . . . . . . . . . . .
479
Remote Access Table
DRAC III
464
. . . . . . . . . . . . . . . . .
Remote Access Table
. . . . . . . .
489
. . . . . . . . . . . . .
497
. . . . . . . . . . . . . . .
502
Remote SNMP Trap Table
Remote Dial-Up Table
Remote User Dial-In Configuration Table
Remote Dial-Out Table
. . . . .
506
. . . . . . . . . . . . . . .
509
Remote Access Variable Values
20 Cluster Group
Cluster Group
480
. . . . . . . . . . . . . . .
Remote User Administration Table .
512
. . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
529
529
. . . . . . . . . . . . . . . . . . . . . .
Cluster Table
529
. . . . . . . . . . . . . . . . . . . .
Cluster Group Variable Values
532
. . . . . . . . . . . . .
21 Baseboard Management
Controller Group . . . . . . .
. . . . . . . . . . .
Baseboard Management Controller Group Tables
533
. . .
533
Baseboard Management Controller Table .
. . . .
533
Baseboard Management Controller Serial
Interface Table . . . . . . . . . . . . . . .
. . . .
537
. . . . .
541
Baseboard Management Controller LAN
Interface Table . . . . . . . . . . . . . .
Contents
9
book.book Page 10 Wednesday, March 6, 2013 12:37 AM
Baseboard Management Controller Group
Variable Values . . . . . . . . . . . . . .
22 Field Replaceable Unit Group
Field Replaceable Unit Group Tables
Field Replaceable Unit Table
. . . . . . .
. . . . . . . .
549
. . . . . . . . . . . .
549
23 Storage Management Group
. . . . . . . . . . . . . .
555
555
557
. . . . . . . . . . . . . . . . . . . .
558
. . . . . . . . . . . . . . . . .
564
. . . . . . . . . . . . . . . . . .
565
. . . . . . . . . . . . . . . . . . .
590
Controller Table .
Channel Table
Enclosure Table .
. . . . . . . . . . . . . . . . . .
595
Array Disk Table
. . . . . . . . . . . . . . . . . .
609
. . . . . .
628
. . . . . . .
631
. . . . . . . . . . . . . . . . . . . . . .
634
Array Disk Enclosure Connection Table
Array Disk Channel Connection Table
Fan Table
Fan Connection Table
Power Supply Table
. . . . . . . . . . . . . . .
640
. . . . . . . . . . . . . . . .
642
Power Supply Connection Table
Temperature Probe Table
. . . . . . . . . .
647
. . . . . . . . . . . . .
649
Temperature Probe Connection Table
. . . . . . .
654
. . . . . .
656
. . . . . . . . . .
661
. . . . . . . . . . . . . . . . . . . .
664
Enclosure Management Module Table
Enclosure Management Module
Connection Table . . . . . . . .
Battery Table
Battery Connection Table
Contents
553
. . . . . . . .
Physical Devices Group
10
. . . . .
. . . . . . . . .
Storage Management Information Group
Global Data Group
549
. . . . . . . . . .
Field Replaceable Unit Group Variable Values
Storage Management Group
545
. . . . . . . . . . . . .
670
book.book Page 11 Wednesday, March 6, 2013 12:37 AM
Logical Devices Group
. . . . . . . . . . . . . . . . .
672
Virtual Disk Table .
. . . . . . . . . . . . . . . . .
672
Virtual Disk Partition
. . . . . . . . . . . . . . . .
684
. . . . . . . . . . . . . . . . .
687
. . . . . . . . . . . . . . . . . .
691
Fluid Cache Table
Fluid Cache Disk
Fluid Cache Pool Table
Array Disk Logical Connection Table
Storage Management Event Group
. . . . . . .
698
. . . . . . . . . . .
700
24 Change Management Group
Inventory Group
Device Group
695
. . . . . . . . . . . . . . .
. . . . . . . . .
703
. . . . . . . . . . . . . . . . . . . . .
703
. . . . . . . . . . . . . . . . . . . . . .
704
. . . . . . . . . . . . . . . .
704
. . . . . . . . . . . . . . . . . . . .
706
Device Group Table
Application Group
. . . . . . . . . . . . . .
707
. . . . . . . . . . . . . . . .
709
Application Group Table
Operating System Group
Inventory Collector Product Information
. . . . . . . .
710
25 Dell Remote Access Controller
Out-of-Band Group . . . . . . . . . . . . . . . . . .713
Product Information
Chassis Status .
. . . . . . . . . . . . . . . . . . .
713
. . . . . . . . . . . . . . . . . . . . .
717
. . . . . . . . . . . . . . .
726
. . . . . . . . . . . . . . . . . . . . .
727
DRsCMCChangeTime
Chassis Power .
CMC Power Information .
. . . . . . . . . . . . . . . .
728
. . . . . . . . . . . . . . . . . .
732
. . . . . . . . . . . . . . . . . . . . . .
734
CMC PSU Information
Chassis Alerts
Contents
11
book.book Page 12 Wednesday, March 6, 2013 12:37 AM
Legacy Alerting
26 Traps
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Understanding the Trap Description
741
. . . . . . . . . . . . . .
745
. . . . . . . . . . . . . . . . . .
746
Miscellaneous Traps
. . . . . . . . . . . . . . . .
Temperature Probe Traps
749
Cooling Device Traps
. . . . . . . . . . . . . . . .
751
Voltage Probe Traps
. . . . . . . . . . . . . . . .
753
Amperage Probe Traps
. . . . . . . . . . . . . . .
755
Chassis Intrusion Traps
. . . . . . . . . . . . . .
757
Redundancy Unit Traps .
. . . . . . . . . . . . . .
758
. . . . . . . . . . . . . . . .
760
. . . . . . . . . . . . . . .
761
. . . . . . . . . . . . . . . .
762
Memory Device Traps
Fan Enclosure Traps
AC Power Cord Traps .
Hardware Log Traps
. . . . . . . . . . . . . . .
764
. . . . . . . . . . . . . . . .
765
Processor Device Status Traps
. . . . . . . . . .
765
. . . . . . . . . . . . . .
767
. . . . . . . . . . . . . . . . . . . .
768
Pluggable Device Traps
Battery Traps
SD Card Device Traps
. . . . . . . . . . . . . . .
769
RAC Traps
. . . . . . . . . . . . . . . . . . . . . . . .
770
BMC Traps
. . . . . . . . . . . . . . . . . . . . . . . .
775
27 Storage Management
Alert Reference. . . . . .
. . . . . . . . . . . . . .
Alert Monitoring and Logging
Viewing Alerts
Contents
747
. . . . . . . . . . . . .
Power Supply Traps
12
739
. . . . . . . . . .
Understanding Trap Severity
Instrumentation Traps
736
781
. . . . . . . . . . . . . .
781
. . . . . . . . . . . . . . . . . . . . .
782
book.book Page 13 Wednesday, March 6, 2013 12:37 AM
Alert Severity Levels
782
. . . . . . . . . . . . . . . . . .
SNMP Support for Storage Management Alerts
. . . .
783
. . . . . . . . . . . . . .
783
SNMP Trap Definitions
. . . . . . . . . . . . . . .
784
SNMP Trap Variables
. . . . . . . . . . . . . . .
784
. . . . . . . . . . . . . . . . . .
785
SNMP Trap Forwarding
Viewing SNMP Traps
Alert Descriptions and Corrective Actions
28 iDRAC7 MIB .
785
. . . . . . .
. . . . . . . . . . . . . . . . . . . . .
787
Supported Systems
. . . . . . . . . . . . . . . . . . .
787
Blade Servers
. . . . . . . . . . . . . . . . . . .
787
Rack and Tower Servers
. . . . . . . . . . .
788
. . . . . . . . . . . . . . .
788
. . . . . . . . . . . . . .
788
iDRAC7 Supported SNMP Versions
iDRAC7 Out-of-Band Group
RAC Information Group
Chassis Information Group .
. . . . . . . . . . . .
790
. . . . . . . . . . . . .
791
. . . . . . . . . . . . . . . . . . . .
794
. . . . . . . . . . . . . . . . . . . . . .
795
System Information Group
Status Group
iDRAC7 Traps
787
. . . . . . . . . . . . . .
Trap Variables
796
. . . . . . . . . . . . . . . . . . .
System Trap Group
. . . . . . . . . . . . . . . . .
797
Storage Trap Group
. . . . . . . . . . . . . . . .
809
Updates Trap Group
. . . . . . . . . . . . . . . .
814
. . . . . . . . . . . . . . . . . .
814
Audit Trap Group
Configuration Trap Group
A Standard Data Type Definitions
Common Data Types
815
. . . . . . . . . . . . .
. . . . . .
819
. . . . . . . . . . . . . . . . . . .
Contents
819
13
book.book Page 14 Wednesday, March 6, 2013 12:37 AM
Variables with Data Types of State Capabilities and
State Capabilities Unique . . . . . . . . . . . . . .
. .
820
. . . . . . . . . . . . . . . . .
822
. . . . . . . . . . . . . . . . . . . . . . . . .
823
Dell Status Data Types .
Dell Date
Full Dates
. . . . . . . . . . . . . . . . . . . . . .
B SNMP Sample Output
Index
14
824
. . . . . . . . . . . . . .
825
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
831
Contents
book.book Page 17 Wednesday, March 6, 2013 12:37 AM
1
Introduction
This reference guide provides information about the Simple Network
Management Protocol (SNMP) Management Information Base (MIB) which
is applicable for Dell OpenManage Version 7.1.
NOTE: This guide contains information that may also be applicable to earlier
OpenManage supported platforms.
This introduction is divided into two sections. The first section,
"Introduction to the SNMP Reference Guide" on page 18, explains the SNMP
Reference Guide design. All essential Simple Network Management Protocol
(SNMP) terms are defined in this section. Some of the vocabulary may seem
complex and unfamiliar to system administrators who are using SNMP for the
first time. SNMP experts can skim this section, and beginners can read the
section more carefully.
The second section, "Introduction to the Server Administrator
SNMP Subagent" on page 34, is a more technical introduction to the
management information base (MIB) that underlies Server Administrator
services.
This section contains information added or updated for the current release.
What’s New in This Release
Storage Management Group MIB
•
Modified the description for Virtual Disk Layout.
•
Added MIB table for Virtual Disk Partition.
•
Added MIB table for Fluid Cache Table.
•
Added MIB table for Fluid Cache Disk.
•
Added MIB table for Fluid Cache Pool Table.
iDRAC7 MIB
•
Updated the supported server information.
List of Platforms, Operating Systems, Browsers support added and
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Template Last Updated - 2/7/2007
Introduction
17
book.book Page 18 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm
deprecated, refer to the Dell OpenManage Server Administrator Version 7.1
User's Guide and Dell Systems Software Support Matrix Version 7.1 at
www.dell.com/support/manuals.
Supported SNMP Versions
Operating System Supported OMSA SNMP version
Windows
SNMP v1
Linux
SNMP v1
Introduction to the SNMP Reference Guide
This reference guide provides a formatted version of the following
Management Information Base that are released with the current version of
Dell OpenManage.
Sections in this guide follow MIB groups and provide explanations and
definitions for the terms used to define MIB objects. Content in this reference
guide is organized as documented in the following subsections.
General Content
Table 1-1 describes the sections that provide general information about the
MIBs documented in this guide.
Table 1-1. General Content Sections in This Guide
Section
Topics
MIB Group
Number
1
Introduction to SNMP basics and to the MIBs that
support Server Administrator services
NA
26
Traps — describes in-band traps defined in the Server 5000
Administrator Instrumentation MIB and out-of-band
traps sent by the Remote Access Controller (RAC)
and Baseboard Management Controller (BMC).
Appendix A
Standard Data Type Definitions — defines standard
data types used in this reference guide.
NA
Appendix B
SNMP Sample Output — provides a sample SNMP
output.
NA
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
18
Introduction
book.book Page 19 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm
Server Administrator Instrumentation MIB
The Server Administrator Instrumentation MIB (filename 10892.mib) provides
instrumentation data that allows you to monitor the health of a system with
SNMP management applications. It provides:
•
Information about the status of temperatures, power supplies, voltages,
currents, fans, and memory at key points in the system
•
Rapid access to detailed fault and performance information gathered by
industry standard systems management agents
•
Version information for Basic Input/Output System (BIOS), firmware,
and operating system
•
A detailed account of every cost of ownership (COO) detail about your system
In addition, traps are sent to report a change in status of the health of critical
components.
The Server Administrator Instrumentation MIB structures its MIB objects
into groups of scalar objects or MIB tables that provide related information.
Table 1-2 describes each Server Administrator Instrumentation MIB group
and lists the MIB group number assigned to the MIB group.
The Server Administrator Instrumentation MIB groups are identified
by the SNMP OID 1.3.6.1.4.1.674.10892.1.<MIB group number>,
where <MIB group number> is the MIB group number assigned to the
MIB group. See the relevant section for more information about the
MIB objects defined in a MIB group.
Table 1-2. Server Administrator Instrumentation MIB Sections in This Guide
Section Topics
MIB Group
Numbers
2
Instrumentation MIB Version Group — defines version
numbers of the Instrumentation MIB
1
3
Systems Management Software Group — defines information
about the systems management software and the supported
systems management standards
100
4
System State Group — defines status, state, and redundancy for 200
a system and its components
5
Chassis Information Group — defines chassis types, events, and 300
indicators
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Introduction
19
book.book Page 20 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm
Table 1-2. Server Administrator Instrumentation MIB Sections in This Guide
Section Topics
MIB Group
Numbers
6
Operating System Group — defines variables for name, version, 400
service pack, and other information about a system’s operating
system
7
System Resource Group — defines variables for input/output
ports, memory, interrupts, and direct memory access
500
8
Power Group — defines variables for power units, power
supplies, and their current and voltage probes
600
9
Thermal Group — defines variables for temperature probes and 700
cooling devices
10
User Security Group — defines variables for creating and
modifying user accounts
11
Remote Flash BIOS Group — defines variables for updating the 900
system’s BIOS remotely
12
Port Group — defines variables for major port types such as
keyboard, monitor, small computer system interface (SCSI),
Universal Serial Bus (USB), and parallel and serial ports
1000
13
Device Group — defines variables for pointing, keyboard,
processor, cache, memory, and personal computer interface
devices
1100
14
Slot Group — defines variables for the system’s slots
1200
15
Memory Group — defines variables for the system’s
physical memory
1300
16
BIOS Setup Control Group — defines variables for BIOS
functions such as boot sequence, speakers, Wake on the local
area network (LAN), diskettes, ports, and
network interface controllers (NIC)
1400
17
Local Response Agent Group — defines variables for global
settings and actions. These variables allow users to
predetermine how the system responds to a particular
type of event
1500
800
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
20
Introduction
book.book Page 21 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm
Table 1-2. Server Administrator Instrumentation MIB Sections in This Guide
Section Topics
MIB Group
Numbers
18
Cost of Ownership Group — defines variables for tracking data 1600
on the system’s service contract, lease, repair records, trouble
tickets, and so on
20
Cluster Group — defines variables for systems that operate as a 1800
cluster
21
Baseboard Management Controller Group — provides
information about the Baseboard Management Controller
(BMC) that may be present in your system. In addition to
providing general information about the BMC, this group
provides information about the serial and local area network
(LAN) interfaces of the BMC
26
Traps — defines the types of alerts that can be sent to report the 5000
status of critical components
1900
Server Administrator Remote Access MIB
The Server Administrator Remote Access MIB (filename dcs3rmt.mib)
provides in-band information about remote access hardware that may be
present in your system.
The Server Administrator Remote Access MIB structures its MIB objects into
groups of scalar objects or MIB tables that provide related information.
Table 1-3 describes each Server Administrator Remote Access MIB group and
lists the MIB group number assigned to the MIB group. The Server
Administrator Remote Access MIB groups are identified by the SNMP OID
1.3.6.1.4.1.674.10892.1.<MIB group number> where <MIB group number> is
the MIB group number assigned to the MIB group. See the relevant section
for more information about the MIB objects defined in a MIB group.
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Introduction
21
book.book Page 22 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm
Table 1-3. Server Administrator Remote Access MIB Sections in This Guide
Section
Topic
MIB Group
Numbers
19
Remote Access Group — provides information about remote 1700
access hardware that may be present in your system and defines
variables for administrative users, SNMP trap destinations,
modem configuration for dial-up networking, dial-in
configuration, and dial-out destinations
Server Administrator Baseboard Management Controller, ASF MIB
The Server Administrator BMC MIB (filename DcAsfSrv.mib) provides
information about the traps sent by BMC. The Server Administrator BMC
MIB structures its MIB objects that provide related information. The BMC
MIB groups are identified by the SNMP OID 1.3.6.1.4.1.3183.1.1.<MIB
group number>. The BMC MIB adheres to ASF 2.0 standard and hence the
enterprise ID is wired for management (3183).
Server Administrator Field Replaceable Unit MIB
The Server Administrator Field Replaceable Unit MIB (filename
dcs3fru.mib) provides information about field replaceable unit (FRU)
hardware that may be present in your system.
The Server Administrator Field Replaceable Unit MIB structures its MIB
objects into groups of scalar objects or MIB tables that provide related
information. Table 1-4 describes each Server Administrator Field Replaceable
Unit MIB group and lists the MIB group number assigned to the MIB group.
The Server Administrator Field Replaceable Unit MIB groups are identified
by the SNMP OID 1.3.6.1.4.1.674.10892.1.<MIB group number> where
<MIB group number> is the MIB group number assigned to the MIB group.
See the relevant section for more information about the MIB objects defined
in a MIB group.
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
22
Introduction
book.book Page 23 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm
Table 1-4. Server Administrator Field Replaceable Unit MIB Sections in This Guide
Section
Topic
MIB Group
Numbers
22
Field Replaceable Unit Group — provides information about 2000
field replaceable units that may be present in your system
Server Administrator Storage Management MIB
The Server Administrator Storage Management MIB (filename dcstorag.mib)
provides storage management data that allows you to monitor the health of
storage resources with SNMP management applications.
Table 1-5 describes each Server Administrator Storage Management MIB
group and lists the MIB group number assigned to the MIB group. The Server
Administrator Storage Management MIB groups are identified by the SNMP
OID 1.3.6.1.4.1.674.<MIB group number> where <MIB group number> is
the MIB group number assigned to the MIB group. See the relevant section
for more information about the MIB objects defined in a MIB group.
Table 1-5. Server Administrator Storage Management MIB Sections in This Guide
Section
Topics
MIB Group
Numbers
23
Storage Management Group — consists of definitions for the 10893
following MIB groups:
• Storage Management Group
• Storage Management Information Group
• Global Data Group
• Physical Devices Group
• Logical Devices Group
• Storage Management Event Group
27
Storage Management Alert Reference — lets you monitor the NA
health of storage resources such as controllers, connectors,
array disks, and virtual disks
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Introduction
23
book.book Page 24 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm
Server Administrator Change Management MIB
The Server Administrator Change Management MIB (filename dellcm.mib)
provides management data that allows you to monitor the inventory of devices
and applications with SNMP management applications.
Table 1-6 describes each Server Administrator Change Management MIB
group and lists the MIB group number assigned to the MIB group. The Server
Administrator Change Management MIB groups are identified by the SNMP
OID 1.3.6.1.4.1.674.<MIB group number> where <MIB group number> is
the MIB group number assigned to the MIB group. See the relevant section
for more information about the MIB objects defined in a MIB group.
Table 1-6. Server Administrator Change Management MIB Sections in This Guide
Section
Topics
MIB Group
Number
24
Change Management Group - describes the inventory data 10899
provided by the Change Management MIB that allows users
to monitor devices and software present on a particular
managed computer chassis
Dell Remote Access Controller Out-of-Band MIB
The Dell Remote Access Controller Out-of-Band MIB (filename
dellRAC.mib) provides management data that allows you to monitor the
Chassis Management Controller. This MIB also contains information on RAC
legacy alerting. Table 1-7 describes each Dell RAC Out-of-Band group and
lists the MIB group number assigned to the MIB group. See the relevant
section for more information about the MIB objects defined in a MIB group.
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
24
Introduction
book.book Page 25 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm
Table 1-7. Dell RAC Out-of-Band MIB
Section
Topics
25
MIB Group
Number
The Dell RAC Out-of-Band MIB consists of information for 2
the following groups:
• "Product Information" on page 713
• "Chassis Status" on page 717
• "Chassis Power" on page 727
• "CMC Power Information" on page 728
• "CMC PSU Information" on page 732
• "Chassis Alerts" on page 734
• "Legacy Alerting" on page 736
How This Guide Defines Technical Terms
The following table provides information about where to find definitions for
technical terms in this reference guide.
Table 1-8. Where to Find Definitions for Technical Terms
Type of Definition
See
Basic SNMP vocabulary.
"Introduction" on page 17
MIB-group-specific variable values.
Sections 3, 5, 7, 8, 9, and 11
MIB-group-specific MIB variables contain links to the through 18.
tables that define these values in the last section of
the section in which these variables are used.
Systems management terms, acronyms, and
commonly managed components referred to in this
reference guide.
Glossary available on the Dell
Support website at
support.dell.com/manuals.
Server Administrator-standard data types that specify Appendix A, "Standard Data
variable values in this reference guide.
Type Definitions" on
page 819.
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Introduction
25
book.book Page 26 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm
SNMP Basic Terminology
It is important to have a good understanding of the key technical terms used
in this guide. This guide provides definitions for all essential terms used in
describing the Server Administrator MIBs. For definitions on all essential
terms and acronyms, see the Glossary available on the Dell Support website at
support.dell.com/manuals.
SNMP Master Agent
Typically, the SNMP agent on a managed system consists of one SNMP
master agent and zero or more SNMP extension agents. This SNMP agent
extendable structure facilitates the addition of new MIB modules without
having to rebuild the entire SNMP agent and is invisible to
SNMP management applications.
The SNMP master agent is responsible for receiving SNMP request protocol
messages from SNMP management applications and sending SNMP response
protocol messages. As part of processing SNMP request protocol messages,
the SNMP master agent typically communicates with one or more SNMP
extension agents. This communication does not involve standard SNMP
protocol messages. The SNMP master agent uses an extension protocol that
shields the SNMP extension agent from the standard SNMP protocol
messages. The extension protocol also provides a way for SNMP extension
agents to send SNMP event notifications (called traps in SNMPv1).
The SNMP master agent is also responsible for sending SNMP event
notification protocol messages to SNMP management applications.
On supported operating systems, the SNMP master agent is provided with
the operating system. For example, on supported Microsoft Windows
operating systems, the Windows SNMP service is the SNMP master agent.
For information on the versions of the SNMP protocol supported by the
SNMP master agent, see the operating system documentation.
SNMP Extension Agent
The SNMP extension agent is responsible for registering the MIB objects that
it supports with the SNMP master agent and then processing requests from
the SNMP master agent for those MIB objects. The SNMP extension agent
also initiates event notifications to the SNMP master agent. The SNMP
extension agent does not receive or send standard SNMP protocol messages.
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
26
Introduction
book.book Page 27 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm
The SNMP extension agent communicates with the SNMP master agent using
an extension protocol defined by the SNMP master agent. The Server
Administrator SNMP subagent is an SNMP extension agent.
Managed Object
A managed object is any item in a computer system that can be singled out
for discovery, monitoring, or user intervention and correction.
NOTE: Not all managed objects described in this guide are supported by all systems.
MIB
A MIB acts as a structured road map for managed objects. As an Application
Programming Interface (API), a MIB allows systems management tools to
retrieve data maintained by an agent. The server administrator MIB is divided
into several major groups of managed objects.
Variable
A variable is a component of a managed object. A temperature probe, for
example, has a variable to describe its capabilities, its health or status,
and certain indexes that you can use to locate specific temperature probes.
One index for the probe would be the probe’s chassis number. Some systems
may have multiple chassis—one chassis for the central processing unit and
another chassis for storage. A chassis within a system can also have more than
one temperature probe. Variables for a temperature probe include its
capabilities, status, chassis index, and index.
One-Based Index
When an index is one-based, counting starts at 1. One-based indexing counts
the first instance as 1, the second index as 2, and so on.
Zero-Based Index
When an index is zero-based, counting starts at 0. Zero-based indexing
counts the first instance as 0, the second index as 1, and so on.
Fields
Managed object variables contain fields. In this reference guide, managed
object variables have the following fields defined:
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Introduction
27
book.book Page 28 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm
Name is the exact string by which the variable is known in the MIB.
MIB variables are named according to the following conventions:
•
Variable names start with a lowercase letter.
•
Spaces are not allowed between words in the variable name.
•
Acronyms are in uppercase letters, except when an acronym is the first
word in the variable name.
•
With the exception of the first letter of the variable name and acronyms,
all other words in the variable name start with capital letters.
The following variable names illustrate these conventions:
•
temperatureProbeLowerCriticalThreshold
•
coolingUnitIndex
•
pCIDeviceSpeed
Object Identifier (OID) is the unique number assigned to an object defined
in a MIB. An OID is written as a sequence of subidentifiers in decimal
notation. Each OID in this reference guide has a prefix that identifies the
managed objects as belonging to Dell: 1.3.6.1.4.1.674. The additional
numbers identify the MIB group and subgroup as well as the table entry
number of any variables.
For example, the OID for the temperature probe managed object table is
700.20 and the variable for the location of the temperature probe
(temperatureProbeLocationName) has an OID of 700.20.1.8. The full OIDs
for these items are 1.3.6.1.4.1.674.10892.1.700.20 for the
temperatureProbeTable and 1.3.6.1.4.1.674.10892.1.700.20.1.8 for the
temperatureProbeLocation. For more information about the structure of
OIDs, see "SNMP Management Information Base Object Identifiers" on
page 36.
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
28
Introduction
book.book Page 29 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm
Description is a brief explanation of what a particular managed object does.
Syntax defines the data type in which the values of the variable must be
expressed. Most variables in this reference guide use standard data types such
as string or boolean. All data types that are unique to server administrator
variables are defined at the end of the section in which they occur. Standard
data types are defined in "Standard Data Type Definitions" on page 819.
Access specifies whether persons with administrative privileges can read but not
modify the value of a variable (read only) or can both read and modify the value
of a variable (read-write).
Frequently Used Terms in Variable Names
The following terms are frequently used in the name of a MIB variable:
Capability refers to the actions an object can perform, or to actions that can
be taken by the object. Hot-pluggable is an example of a capability. If a card is
hot-pluggable, it can be replaced while a system is running. Capability settings
refer to the capabilities of the object that the user can select from and activate
if desired. Capability settings allow users of the server administrator to
predetermine how an object behaves under specific conditions.
Settings are the conditions of a manageable object that determine what
happens when a certain value is detected in a component. For example, a user
can set the upper critical threshold of a temperature probe to 75 degrees
Celsius. If the probe reaches that temperature, the setting causes an alert to
be sent to the management console. Some settings, when reached, can trigger
a system shutdown or other response to prevent damage to the system.
State refers to the condition of an object that has more than one condition.
For example, an object may be in a not ready or in an enabled state.
Status refers to the health of an object or how the object is functioning. For
example, the status of a temperature probe that is measuring acceptable
temperatures would be reported as normal. When the probe begins reading
temperatures that exceed limits set by the user, it reports a critical status.
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Introduction
29
book.book Page 30 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm
Tables
This reference guide contains two types of tables: tables that are used to
organize and define variable values and tables that define MIB objects.
Readers must understand the difference between these two types of tables.
SNMP Tables
Most of the MIB objects defined in this reference guide are organized into
SNMP tables. SNMP tables organize data into two-dimensional structural
arrays. In SNMP, objects that have a relationship to other objects are called
columnar objects. Columnar objects are objects used to form lists and tables.
When a MIB group is divided into one or more discrete tables, the word table
has a technical meaning. An example is the section of this reference guide
entitled Universal Unique Identifier (UUID). The UUID object has a type
and a value that uniquely identifies an object such as a chassis. The table
defines all of the variables that comprise the managed object UUID.
The following table is an example of an SNMP table. The table contains
variables that must occur in a definite sequence. In the example table the
defined variables are UUID Chassis Index, UUID Index, UUID Type, and
UUID Value.
Example SNMP Table
UUID Table
These objects comprise the Server Administrator definitions for the UUID.
Name
uUIDTable
Object ID
1.3.6.1.4.1.674.10892.1.300.20
Description Defines the UUID table.
Syntax
SEQUENCE OF UUIDTableEntry
Access
Not accessible
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
30
Introduction
book.book Page 31 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm
UUID Table Entry
Name
uUIDTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.300.20.1
Description Defines the UUID table entry.
Syntax
UUIDTableEntry
Access
Not accessible
Index
uUIDIndex, uUIDchassisIndex
UUID Chassis Index
Name
uUIDchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.20.1.1
Description Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
UUID Index
Name
uUIDIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.20.1.2
Description Defines the index of the UUID in a specified chassis.
Syntax
DellObjectRange
Access
Read-only
UUID Type
Name
uUIDType
Object ID
1.3.6.1.4.1.674.10892.1.300.20.1.3
Description Defines the type of the UUID for this chassis.
Syntax
DellUUIDType
Access
Read-only
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Introduction
31
book.book Page 32 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm
UUID Value
Name
uUIDValue
Object ID
1.3.6.1.4.1.674.10892.1.300.20.1.4
Description Defines the value of the UUID for this chassis.
Syntax
Octet String (SIZE[16])
Access
Read-only
Reference Guide Content Tables
NOTE: Variable values are defined for any variable that is Server
Administrator-specific. Industry-standard variable definitions are documented
in "Standard Data Type Definitions" on page 819.
Some of the tables in this guide have no technical significance in SNMP.
These tables are designed to show information in a readable form. The
following table, for example, defines the Server Administrator-specific variable,
DellFanControlCapabilities. The table provides the name of the variable, its data
type, the values that are valid for the variable, and the meaning of each value.
Table 1-9. Example Variable Type Definition Table
Variable Name: DellFanControlCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
The fan’s capabilities are unknown.
lowSpeedCapable(2)
The fan can be set to low speed.
highSpeedCapable(4)
The fan can be set to high speed.
lowOrhighSpeedCapable(6)
The fan can be set to low or high speed.
This type of table is used throughout the reference guide to list and define
variable values. Tables that explain Server Administrator-specific variable
values are located in the final section of sections that define Server
Administrator-specific variables. In the preceding example, the variable name
is DellFanControlCapabilities. This variable must be expressed as an integer
and has four possible values: unknown, lowSpeedCapable,
highSpeedCapable, and lowOrhighSpeedCapable.
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
32
Introduction
book.book Page 33 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm
Section Organization
Sections in this reference guide are based on the Server Administrator MIBs,
so the complexity of each section depends on the complexity of each MIB
group. The first section provides a high-level introduction to the MIB group.
If the group is defined by one or more tables, the second section lists these
tables. The third section documents the variables that comprise the group,
and if applicable, the variables that comprise the tables. The fourth section
contains definitions for any Server Administrator-specific variables that are
used in the section. The following example shows the typical content of these
four sections:
1 BIOS Setup Control Group
This section explains the purpose of the MIB group and summarizes the
major features of the component groups.
2 BIOS Group Tables
If there is more than one SNMP table for a group, this section lists all of
the tables. For this BIOS group example, there are eight tables listed.
In each section, double-clicking any table on the list takes you to that table.
•
BIOS Setup Control Table
•
SCSI Control Table
•
Parallel Port Control Table
•
Serial Port Control Table
•
USB Control Table
•
IDE Control Table
•
Diskette Control Table
•
Network Interface Control Table
3 Variables that make up each table in the group
This section documents the variables for the eight tables that comprise the
BIOS group.
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Introduction
33
book.book Page 34 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm
4 BIOS Variable Values
This section explains any Server Administrator-specific variables and data
types that are used in this section. In the BIOS group example, there are
17 unique, Server Administrator-specific variable meanings. Information on
each Server Administrator-specific variable is presented in a formatted table.
Other Documents You May Need
In addition to this guide, you can access the following guides available on the
Dell Support website at support.dell.com/manuals. On the Manuals page,
click Software→Systems Management. Click the appropriate product link on
the right-side to access the documents.
•
The Server Administrator Messages Reference Guide lists the messages that
you can receive on your systems management console or on your operating
system’s event viewer. This guide explains the text, severity, and cause of
each message that the server administrator issues.
•
The Server Administrator CIM Reference Guide documents the Common
Information Model (CIM) provider, an extension of the standard
management object format (MOF) file. The Server-Administrator CIM
provider documents supported classes of management objects.
•
The Glossary provides information on the terms used in this document.
Introduction to the Server Administrator
SNMP Subagent
This guide provides formatted information drawn primarily from the MIB
files written for the Server Administrator services that support the SNMP
protocol.
For each of the variables defined in the MIBs, the following fields are specified:
•
Variable name
•
OID or unique identifying number
•
Description
•
Data type of the variable (for example: integer, string, octet string)
•
Whether the variable is accessible, not accessible, read-only, or read-write
•
Index or indexes, if applicable
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
34
Introduction
book.book Page 35 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm
For each MIB group that has unique variable definitions, tables are included
in the last section of the section to explain the meaning of the terms.
Standards for writing MIBs are defined by the Internet Engineering Task
Force (IETF). Structure of Management Information (SMI) is a standard that
specifies the rules for defining the structure and type of managed objects and
events in a MIB. SMIv1 is specified in Request For Comments (RFC) 1155.
The Server Administrator MIB conforms to the SMIv1 standard.
SNMP is a systems management standard originally designed for network
management. SNMP manages much more than networks. Information
Technology (IT) professionals use SNMP for monitoring and managing
computer systems and the various components and peripherals supported by
their systems.
SNMP standards are defined by the Internet Engineering Task Force (IETF).
SNMP version 1 was published in August 1988 and is the most commonly
supported version of SNMP. SNMP version 2 was first published in May 1993,
but has not gained widespread market acceptance. SNMP version 3 was
recently completed and has addressed security issues that exist in version 1.
All SNMP systems consist of one or more managed systems that provide data
through an SNMP agent to a management system. The management system
provides a user interface to view data from the managed systems. The
management system and managed systems communicate over a network
(typically through User Datagram Protocol/Internet Protocol [UDP/IP]).
The management system and a managed system communicate by means of a
common data schema. SNMP MIB files define the structure, type, and values
of the SNMP data. While MIBs can be standardized or enterprise specific,
most operating systems supply SNMP agents for the standard MIB-I and
MIB-II schemas. MIB-I defines a base set of standard management information
for systems implementing the Internet Protocol (IP) suite. MIB-II defines
characteristics of the system, characteristics of network interfaces, and
characteristics of components of the IP on the system. In addition to the
standard MIBs, many hardware vendors have defined MIBs that provide
management data specific to their systems and peripheral devices.
Monitored data can be retrieved through SNMP using the Get command.
Typically, this command requires the host name or IP address of the target
machine as well as the OID of the data to retrieve. Exact details are dependent
on the operating system and the development tools being used to create the
management application. The Get command has a variant known as GetNext.
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Introduction
35
book.book Page 36 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm
SNMP Management Information Base Object Identifiers
Each data class within a Management Information Base (MIB) is defined by
an Object Identifier (OID). OIDs are unique across all MIBs. An OID
consists of a series of digits separated by periods. The OID functions in a
similar fashion to a phone number. The phone number 011-512-471-0000
uniquely identifies a single phone. The phone number can be broken down
into a number of components to uniquely identify a phone. The first
component, 011, is the country code for the United States. The second
component, 512, identifies the area code for central Texas. The third
component, 471, is the phone exchange for a large state university in the city
of Austin. The final component, 0000, is the main switchboard.
There are two main differences between the phone number example and an
actual OID. The first difference is that there are many more components in
an OID, up to 128. The combination of these components is called an OID
prefix. The second difference is that OIDs support the concept of indexes or
keys. The OID prefix specifies the data class but does not specify an instance of
the data within the class. Indexes can be used to identify the instances of a data
class. These indexes are referred to as the OID suffix.
The assignment of values for each OID prefix component can be illustrated
by using a tree structure. The following is an example of an OID assignment:
ROOT
CCITT(0)
ISO(1)
ORG(3)
DOD(6)
INTERNET(1)
MGMT(2)
MIB(1)
EXPERIMENTAL(3)
PRIVATE(4)
ENTERPRISES(1)
DELL
(674)
SNMPv2(6)
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
36
Introduction
book.book Page 37 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm
In the preceding example, the OID prefix for the Dell enterprise would be
1.3.6.1.4.1.674.
The numbers in boldface type show the categories and numbers that apply to
Server Administrator. All Server Administrator-defined OIDs consist of
1.3.6.1.4.1.674 followed by additional component values.
SNMP Security
SNMP version 1 has a very limited security mechanism. SNMP agents
support the use of a community string, which is configured at each SNMP
agent and is passed as a part of all SNMP request messages. There is no
verification that the requester is actually a member of the
specified community. As most system and network management data is not
confidential, this limited security is acceptable for Get types of requests. On
the other hand, this security is not acceptable for Set types of operations
where an SNMP request could power off a system, reconfigure a redundant
array of independent disks (RAID) card, and so on. Some vendors have
chosen not to support SNMP Set operations for this reason. Server
Administrator is able to support SNMP Set operations because its SNMP
agents implement a hash/digest mechanism to prevent unauthorized SNMP
Set operations. One limitation of this practice is that only server
administrator-developed SNMP management applications have the capability
to support the hash/digest mechanism.
NOTE: The default SNMP agent configuration usually includes a SNMP community
name such as public. For security reasons, change the SNMP community names
from their default values. For information about changing SNMP community names,
see the Dell OpenManage Server Administrator User’s Guide available on the Dell
Support website at support.dell.com/manuals. For additional guidelines, see the
Securing an SNMP Environment article, dated May 2003, in the Dell Power
Solutions magazine. This magazine is also available at dell.com/powersolutions.
NOTE: Server Administrator provides support to enable or disable SNMP Set
operations. For more information on enabling or disabling SNMP Set operations in
Server Administrator, see the Dell OpenManage Server Administrator User’s Guide
or the Dell OpenManage Server Administrator Command Line Interface
User's Guide on the Dell Support website at support.dell.com/manuals.
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Introduction
37
book.book Page 38 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm
Management Actions
Management actions can be performed using the SNMP Set command.
These actions can consist of configuring a phone number for the system’s
owner, rebooting a system, or changing the asset tag of the system. See the
previous section, "SNMP Security" on page 37, for limitations on Set
operations.
SNMP Traps
SNMP is frequently used to monitor systems for fault conditions such as
temperature violations, hard drive failures, and so on. Management
applications can monitor for these conditions by polling the appropriate
OIDs with the Get command and analyzing the returned data. This method
has its drawbacks. If it is done frequently, significant amounts of network
bandwidth can be consumed. If it is done infrequently, the response to the
fault condition may not occur in a timely fashion. SNMP traps avoid these
limitations of the polling method.
An SNMP trap is an asynchronous event indicating that something
significant has occurred. This is analogous to a pager receiving an important
message, except that the SNMP trap frequently contains all the information
needed to diagnose a fault.
Two drawbacks to SNMP traps are that they are sent using UDP, which is not
a guaranteed delivery mechanism, and that they are not acknowledged by
the receiver.
An SNMP trap message contains the trap’s enterprise OID, the agent IP
address, a generic trap ID, the specific trap ID, a time stamp, and zero or
more variable bindings (varbinds). The combination of an enterprise OID
and a specific trap ID uniquely identifies each Server Administrator-defined
trap. A varbind consists of an OID and its value and provides additional
information about the trap.
In order for a management system to receive SNMP traps from a managed
system, the node must be configured to send traps to the management
system. Trap destination configuration is dependent on the operating system.
When this configuration is done, a management application on the
management system can wait for traps and act on them when received.
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
38
Introduction
book.book Page 39 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm
For a list of traps supported by the Server Administrator Instrumentation
Service, see "Instrumentation Traps" on page 696. For information on Server
Administrator Storage Management traps, see "Storage Management Alert
Reference" on page 753.
For a list of traps supported by the Remote Access Controller, see "RAC
Traps" on page 742, "BMC Traps" on page 747 and "iDRAC7 Traps" on page
767.
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Introduction
39
book.book Page 40 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc1.fm
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
40
Introduction
book.book Page 41 Wednesday, March 6, 2013 12:37 AM
2
Instrumentation MIB Version Group
The Instrumentation Management Information Base (MIB) Version Group
defines the attributes that identify the version of the Instrumentation MIB
supported by the systems management software.
The mIBMajorVersionNumber, mIBMinorVersionNumber, and
mIBMaintenanceVersionNumber attributes are scalar objects, meaning that
they are not related to other MIB objects and are thus not placed in a table.
Management Information Base Major Version
Number
Name
mIBMajorVersionNumber
Object ID
1.3.6.1.4.1.674.10892.1.1.1.0
Description
Defines the major version number of the version of this MIB
supported by the systems management software. For example,
if the MIB version is 1.2.3, the major version number is 1.
A major version number change indicates a major change in
object functionality.
Syntax
DellUnsigned8BitRange
Access
Read-only
Instrumentation MIB Version Group
41
book.book Page 42 Wednesday, March 6, 2013 12:37 AM
Management Information Base Minor Version
Number
Name
mIBMinorVersionNumber
Object ID
1.3.6.1.4.1.674.10892.1.1.2.0
Description
Defines the minor version number of the version of this MIB
supported by the systems management software. For example,
if the MIB version is 1.2.3, the minor version number is 2.
A minor revision provides additional support for new objects as
well as problem fixes.
Syntax
DellUnsigned8BitRange
Access
Read-only
Management Information Base Maintenance
Version Number
Name
mIBMaintenanceVersionNumber
Object ID
1.3.6.1.4.1.674.10892.1.1.3.0
Description
Defines the maintenance version number for the version of this
MIB supported by the systems management software.
For example, if the MIB version is 1.2.3, the maintenance
version number is 3.
Syntax
DellUnsigned8BitRange
Access
Read-only
42
Instrumentation MIB Version Group
book.book Page 43 Wednesday, March 6, 2013 12:37 AM
Systems Management Software
Group
3
The Systems Management Software Group allows users to see information
about the standards and software that are supported by the agent of a
particular managed computer chassis. The Systems Management Software
Group classifies each computer chassis according to the systems management
standard that the agent supports.
Additional objects define the universal resource locator (URL) of the systems
management software and the language in which systems management
information displays. Defining these objects enables users to manage a
system using an internet browser. You can access Server Administrator using
the secure hypertext transfer protocol (https) and a pre-assigned port number
of 1311, or you can specify a port number of your own choosing.
NOTE: Using the Software→Server Preferences menu of Server Administrator, you
can bind to either one IP address or to all IP addresses.
To manage a system locally using Server Administrator, type the following in
the address field of your browser: https://localhost:<1311 or user-specified
port number>
To manage a system remotely using Server Administrator, type one of the
following in the address field of your browser:
https://<systemname>:<1311 or user specified port number> or https://<IP
address>:<1311 or user specified port number>
Systems Management Software
The following objects describe the fields for server administrator systems
management information. The systems management software variables are
scalar objects, meaning that they are not related to other management
information base (MIB) objects and are thus not placed in a table.
Systems Management Software Group
43
book.book Page 44 Wednesday, March 6, 2013 12:37 AM
Systems Management Software Name
Name
systemManagementSoftwareName
Object ID
1.3.6.1.4.1.674.10892.1.100.1
Description
Defines the systems management software product name.
Syntax
DellString
Access
Read-only
Systems Management Software Version Number Name
Name
systemManagementSoftwareVersionNumberName
Object ID
1.3.6.1.4.1.674.10892.1.100.2
Description
Defines the version number of the systems management
software.
Syntax
DellString
Access
Read-only
Systems Management Software Build Number
Name
systemManagementSoftwareBuildNumber
Object ID
1.3.6.1.4.1.674.10892.1.100.3
Description
Defines the build number of the systems management software.
Syntax
DellUnsigned16BitRange
Access
Read-only
Systems Management Software Description Name
Name
systemManagementSoftwareDescriptionName
Object ID
1.3.6.1.4.1.674.10892.1.100.4
Description
Defines the description of the systems management software.
Syntax
DellString
Access
Read-only
44
Systems Management Software Group
book.book Page 45 Wednesday, March 6, 2013 12:37 AM
Systems Management Software Supported Protocol
Name
systemManagementSoftwareSupportedProtocol
Object ID
1.3.6.1.4.1.674.10892.1.100.5
Description
Defines the systems management standards (SNMP or CIM)
supported by the systems management software.
Syntax
SMSSupportedTypes (See Table 3-1)
Access
Read-only
Systems Management Software Preferred Protocol
Name
systemManagementSoftwarePreferredProtocol
Object ID
1.3.6.1.4.1.674.10892.1.100.6
Description
Defines the preferred systems management standard for the
systems management software.
Syntax
SMSSupportedTypes (See Table 3-1)
Access
Read-only
Systems Management Software Update Level Name
Name
systemManagementSoftwareUpdateLevelName
Object ID
1.3.6.1.4.1.674.10892.1.100.7
Description
Defines the update level of the system management software.
Syntax
DellString
Access
Read-only
Systems Management Software URL Name
Name
systemManagementSoftwareURLName
Object ID
1.3.6.1.4.1.674.10892.1.100.8
Description
Defines the universal resource locator (URL) of the systems
management software.
Syntax
DisplayString (SIZE (0..1024))
Systems Management Software Group
45
book.book Page 46 Wednesday, March 6, 2013 12:37 AM
Name
systemManagementSoftwareURLName
Access
Read-only
Systems Management Software Language Name
Name
systemManagementSoftwareLanguageName
Object ID
1.3.6.1.4.1.674.10892.1.100.9
Description
Defines the language of the systems management software.
Syntax
DisplayString (SIZE (0..255))
Access
Read-only
Systems Management Software Global Version Name
Name
systemManagementSoftwareGlobalVersionName
Object ID
1.3.6.1.4.1.674.10892.1.100.10
Description
Defines the global version of the systems management software.
Syntax
DellString
Access
Read-only
Systems Management Software Feature Flags
Name
systemManagementSoftwareFeatureFlags
Object ID
1.3.6.1.4.1.674.10892.1.100.11
Description
Defines the features of the systems management software.
Syntax
SMSFeatureFlags (See Table 3-2)
Access
Read-only
Systems Management Software SNMP Agent Feature Flags
Name
systemManagementSoftwareSNMPAgentFeatureFlags
Object ID
1.3.6.1.4.1.674.10892.1.100.12
Description
Defines the features of the SNMP agent software provided by the
operating system.
46
Systems Management Software Group
book.book Page 47 Wednesday, March 6, 2013 12:37 AM
Name
systemManagementSoftwareSNMPAgentFeatureFlags
Syntax
SMSSNMPAgentFeatureFlags (See Table 3-3)
Access
Read-only
Systems Management Software Manufacturer Name
Name
systemManagementSoftwareManufacturerName
Object ID
1.3.6.1.4.1.674.10892.1.100.13
Description
Defines the manufacturer of the systems management software.
Syntax
DellString
Access
Read-only
Systems Management Software Variable Values
This section includes definitions of server administrator-specific variable
values used in this section.
Table 3-1. Systems Management Software Supported Standards
Variable Name: SMSSupportedTypes
Data Type: Integer
Possible Data Values
Meaning of Data Value
supportsSNMP(1)
This system supports SNMP.
supportsDMI(2)
This system supports DMI.
supportsSNMPandDMI(3)
This system supports SNMP and DMI.
supportsCIMOM(4)
This system supports CIM.
supportsSNMPandCIMOM(5)
This system supports SNMP and CIM.
Systems Management Software Group
47
book.book Page 48 Wednesday, March 6, 2013 12:37 AM
Table 3-2. Systems Management Software Feature Flags
Variable Name: SMSFeatureFlags
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The Systems Management Software
features are not enabled.
webOneToOneManagementPreferred(1) The web 1:1 management preferred
feature is enabled.
Table 3-3. Systems Management Software SNMP Agent Feature Flags
Variable Name: SMSSNMPAgentFeatureFlags
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The Systems Management Software
SNMP agent features are not enabled.
supportsSparseTables(1)
The SNMP agent supports sparse tables.
48
Systems Management Software Group
book.book Page 49 Wednesday, March 6, 2013 12:37 AM
4
System State Group
The Management Information Base (MIB) variables presented in this section
enable you to track various attributes that describe the state of the critical
components supported by your system. Components monitored under the
System State Group include power supplies, AC power cords, AC power
switches, and cooling devices, as well as temperature, fan, amperage,
and voltage probes.
System State Group Table
The System State Group defines objects in the System State MIB table.
System State Table
The systemStateGlobalSystemStatus variable provides overall system health
status and includes rolled-up (that is, worst) status for Instrumentation and
Storage. This variable monitors the overall system health status. It reflects
changes to systemStateChassisStatus variable, which represents
Instrumentation health status and agentGlobalSystemStatus (dcstorag.mib),
which represents Storage health status.
The systemStateChassisStatus variable provides the rolled-up health status
for the subsystems associated with the chassis that is represented by the row
in the systemStateTable. Changes to the variables in "List 1" on page 50, each
of which indicates the rolled-up health status of all the components of the
corresponding subsystem, are reflected in systemStateChassisStatus variable.
For example, systemStatePowerSupplyStatusCombined provides the rolledup status of all power supplies for the chassis.
The variables in "List 2" on page 50 provide the health status of each
component of the corresponding subsystem. Each octet of the value
represents a component. If a power supply fails, the corresponding entry in
systemStatePowerSupplyStatusDetails,
systemStatePowerSupplyStatusCombined, systemStateChassisStatus, and
systemStateGlobalSystemStatus transitions to critical.
System State Group
49
book.book Page 50 Wednesday, March 6, 2013 12:37 AM
List 1
Variables that provide rolled-up health status for all components in associated
subsystem in chassis:
•
systemStatePowerSupplyStatusCombined
•
systemStateVoltageStatusCombined
•
systemStateAmperageStatusCombined
•
systemStateCoolingDeviceStatusCombined
•
systemStateTemperatureStatusCombined
•
systemStateMemoryDeviceStatusCombined
•
systemStateChassisIntrusionStatusCombined
•
systemStateACPowerCordStatusCombined
•
systemStateEventLogStatus
•
systemStatePowerUnitStatusCombined
•
systemStateCoolingUnitStatusCombined
•
systemStateACPowerSwitchStatusCombined
•
systemStateRedundantMemoryUnitStatusCombined
•
systemStateProcessorDeviceStatusCombined
•
systemStateBatteryStatusCombined
•
systemStateSDCardUnitStatusCombined
•
systemStateSDCardDeviceStatusCombined
List 2
Variables that provide health status of each component in associated
subsystem in chassis:
50
•
systemStatePowerSupplyStatusDetails
•
systemStateVoltageStatusDetails
•
systemStateAmperageStatusDetails
•
systemStateCoolingDeviceStatusDetails
•
systemStateTemperatureStatusDetails
•
systemStateMemoryDeviceStatusDetails
System State Group
book.book Page 51 Wednesday, March 6, 2013 12:37 AM
•
systemStateChassisIntrusionStatusDetails
•
systemStateACPowerCordStatusDetails
•
systemStatePowerUnitStatusList
•
systemStateCoolingUnitStatusList
•
systemStateACPowerSwitchStatusList
•
systemStateRedundantMemoryUnitStatusList
•
systemStateProcessorDeviceStatusList
•
systemStateBatteryStatusList
•
systemStateSDCardUnitStatusList
•
systemStateSDCardDeviceStatusList
System State Table
The following object sets up the System State Table:
Name
systemStateTable
Object ID
1.3.6.1.4.1.674.10892.1.200.10
Description
Defines the System State Table.
Syntax
SEQUENCE OF SystemStateTableEntry
Access
Not accessible
System State Table Entry
Name
systemStateTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1
Description
Defines the System State Table entry.
Syntax
SystemStateTableEntry
Access
Not accessible
Index
systemStatechassisIndex
System State Group
51
book.book Page 52 Wednesday, March 6, 2013 12:37 AM
System State Chassis Index
Name
systemStatechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
System State Global System Status
Name
systemStateGlobalSystemStatus
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.2
Description
Defines the global system status of all chassis being monitored by
this instrumentation instance.
Syntax
DellStatus
Access
Read-only
System State Chassis State
Name
systemStateChassisState
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.3
Description
Defines the system state of this chassis.
Syntax
DellStateSettings
Access
Read-only
System State Chassis Status
52
Name
systemStateChassisStatus
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.4
Description
Defines the system status of this chassis.
Syntax
DellStatus
Access
Read-only
System State Group
book.book Page 53 Wednesday, March 6, 2013 12:37 AM
System State Power Unit State Details
Name
systemStatePowerUnitStateDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.5
Description
Defines the state of all power units in this chassis. The results are
returned as a binary octet string. Each byte of the octet string
represents the state of a specific power unit. The first byte returned
represents the state of the first power unit, the second byte returned
represents the state of the second power unit, and so on. The bytes
have the same definition type as DellStateSettings.
Syntax
Octet String (Size (1..128))
Access
Read-only
System State Power Unit Status Redundancy
Name
systemStatePowerUnitStatusRedundancy
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.6
Description
Defines the system status of the power unit(s) in this chassis.
Syntax
DellStatus
Access
Read-only
System State Power Unit Status Details
Name
systemStatePowerUnitStatusDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.7
Description
Defines the status of all power units in this chassis. The results are
returned as a binary octet string. Each byte of the octet string
represents the status of a specific power unit. The first byte returned
represents the status of the first power unit, the second byte
returned represents the status of the second power unit, and so on.
The bytes have the same definition type as DellStatusRedundancy.
Syntax
Octet String (Size (1..128))
Access
Read-only
System State Group
53
book.book Page 54 Wednesday, March 6, 2013 12:37 AM
System State Power Supply State Details
Name
systemStatePowerSupplyStateDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.8
Description
Defines the state of all power supplies in this chassis. The results are
returned as a binary octet string. Each byte of the octet string
represents the state of a specific power supply. The first byte returned
represents the state of the first power supply, the second byte
returned represents the state of the second power supply, and so on.
The bytes have the same definition type as DellStateSettings.
Syntax
Octet String (Size (1..128))
Access
Read-only
System State Power Supply Status Combined
Name
systemStatePowerSupplyStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.9
Description
Defines the status of all power supplies in this chassis.
Syntax
DellStatus
Access
Read-only
System State Power Supply Status Details
Name
systemStatePowerSupplyStatusDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.10
Description
Defines the status of all power supplies in this chassis. The results
are returned as a binary octet string, Each byte of the octet string
represents the status of a specific power supply. The first byte
returned represents the status of the first power supply, the second
byte returned represents the status of the second power supply,
and so on. The bytes have the same definition type as DellStatus.
Syntax
Octet String (Size (1..128))
Access
Read-only
54
System State Group
book.book Page 55 Wednesday, March 6, 2013 12:37 AM
System State Voltage State Details
Name
systemStateVoltageStateDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.11
Description
Defines the state of all voltage probes in this chassis. The results are
returned as a binary octet string. Each byte of the octet string
represents the status of a specific voltage probe. The first byte returned
represents the status of the first voltage probe, the second byte
returned represents the status of the second voltage probe, and so
on. The bytes have the same definition type as DellStateSettings.
Syntax
Octet String (Size (1..128))
Access
Read-only
System State Voltage Status Combined
Name
systemStateVoltageStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.12
Description
Defines the status of all voltage probes in this chassis.
Syntax
DellStatus
Access
Read-only
System State Voltage Status Details
Name
systemStateVoltageStatusDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.13
Description
Defines the status of all voltage probes in this chassis.
Syntax
Octet String (Size (1..128))
Access
Read-only
System State Group
55
book.book Page 56 Wednesday, March 6, 2013 12:37 AM
System State Amperage State Details
Name
systemStateAmperageStateDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.14
Description
Defines the state of all current probes in this chassis. The results are
returned as a binary octet string. Each byte of the octet string
represents the status of a specific current probe. The first byte
returned represents the state of the first current probe, the second
byte returned represents the state of the second current probe, and
so on. The bytes have the same definition type as DellStateSettings.
Syntax
Octet String (Size (1..128))
Access
Read-only
System State Amperage Status Combined
Name
systemStateAmperageStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.15
Description
Defines the status of all amperage probes in this chassis. The result
is returned as a combined status value. The value has the same
definition type as DellStatus.
Syntax
DellStatus
Access
Read-only
System State Amperage Status Details
Name
systemStateAmperageStatusDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.16
Description
Defines the status of all amperage probes in this chassis. The results
are returned as a binary octet string. Each byte of the octet string
represents the status of a specific amperage probe. The first byte
returned represents the status of the first amperage probe, the
second byte returned represents the status of the second amperage
probe, and so on. The bytes have the same definition type as
DellStatus.
Syntax
Octet String (Size (1..128))
Access
Read-only
56
System State Group
book.book Page 57 Wednesday, March 6, 2013 12:37 AM
System State Cooling Unit State Details
Name
statesystemStateCoolingUnitStateDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.17
Description
Defines the state of all cooling units in this chassis. The results are
returned as a binary octet string. Each byte of the octet string
represents the state of a specific cooling unit. The first byte returned
represents the state of the first cooling unit, the second byte
returned represents the state of the second cooling unit, and so on.
The bytes have the same definition type as DellStateSettings.
Syntax
Octet String (Size (1..128))
Access
Read-only
System State Cooling Unit Status Redundancy
Name
systemStateCoolingUnitStatusRedundancy
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.18
Description
Defines the state of all cooling units in this chassis.
Syntax
DellStatusRedundancy
Access
Read-only
System State Cooling Unit State Details
Name
systemStateCoolingUnitstateDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.19
Description
Defines the state of all cooling units in this chassis. The results are
returned as a binary octet string. Each byte of the octet string
represents the state of a specific cooling unit. The first byte returned
represents the state of the first cooling unit, the second byte
returned represents the state of the second cooling unit, and so on.
The bytes have the same definition type as DellStateSettings.
Syntax
Octet String (Size (1..128))
Access
Read-only
System State Group
57
book.book Page 58 Wednesday, March 6, 2013 12:37 AM
System State Cooling Device State Details
Name
systemStateCoolingDeviceStateDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.20
Description
Defines the state of all cooling devices in this chassis. The results are
returned as a binary octet string. Each byte of the octet string
represents the state of a specific cooling device. The first byte returned
represents the state of the first cooling device, the second byte
returned represents the state of the second cooling device, and so
on. The bytes have the same definition type as DellStateSettings.
Syntax
Octet String (Size (1..128))
Access
Read-only
System State Cooling Device Status Combined
Name
systemStateCoolingDeviceStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.21
Description
This attribute defines the cooling device status of all cooling devices
in this chassis. The results is returned as a combined status value.
The value has the same definition type as DellStatus.
Syntax
DellStatus
Access
Read-only
System State Cooling Device Status Details
Name
systemStateCoolingDeviceStatusDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.22
Description
Defines the status of all cooling devices in this chassis. The results
are returned as a binary octet string. Each byte of the octet string
represents the status of a specific cooling device. The first byte
returned represents the status of the first cooling device, the second
byte returned represents the status of the second cooling device,
and so on. The bytes have the same definition type as DellStatus.
Syntax
Octet String (Size (1..128))
Access
Read-only
58
System State Group
book.book Page 59 Wednesday, March 6, 2013 12:37 AM
System State Temperature State Details
Name
systemStateTemperatureStateDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.23
Description
Defines the state of all temperature probes in this chassis.
The results are returned as a binary octet string. Each byte of the
octet string represents the state of a specific temperature probe.
The first byte returned represents the state of the first temperature
probe, the second byte returned represents the status of the second
temperature probe, and so on. The bytes have the same definition
type as DellStateSettings.
Syntax
Octet String (Size(1..128))
Access
Read-only
System State Temperature Status Combined
Name
systemStateTemperatureStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.24
Description
Defines the status of all temperature probes in this chassis.
The result is returned as a combined status value. The value has the
same definition type as DellStatus.
Syntax
DellStatus
Access
Read-only
System State Temperature Status Details
Name
systemStateTemperatureStatusDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.25
Description
Defines the status of all temperature probes in this chassis. The first
byte returned represents the status of the first temperature probe,
the second byte returned represents the status of the second
temperature probe, and so on.
Syntax
Octet String (Size(1..128)
Access
Read-only
System State Group
59
book.book Page 60 Wednesday, March 6, 2013 12:37 AM
System State Memory Device State Details
Name
systemStateMemoryDeviceStateDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.26
Description
Defines the state of all memory devices in this chassis. The results
are returned as a binary octet string. Each byte of the octet string
represents the state of the specific memory device. The first byte
returned represents the state of the first memory device, the second
byte returned represents the status of the second memory device,
and so on. The bytes have the same definition type as
DellStateSettings.
Syntax
Octet String (Size(1..128)
Access
Read-only
System State Memory Device Status Combined
Name
systemStateMemoryDeviceStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.27
Description
Defines the status of all memory devices in this chassis.
Syntax
DellStatus
Access
Read-only
System State Memory Device Status Details
Name
systemStateMemoryDeviceStatusDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.28
Description
Defines the status of all memory devices in this chassis. The results
are returned as a binary octet string. Each byte of the octet string
represents the status of a specific memory device. The first byte
returned represents the status of the first memory device, the
second byte returned represents the status of the second memory
device, and so on. The bytes have the same definition type as
DellStatus.
Syntax
Octet String (Size(1..128)
Access
Read-only
60
System State Group
book.book Page 61 Wednesday, March 6, 2013 12:37 AM
System State Chassis Intrusion State Details
Name
systemStateChassisIntrusionStateDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.29
Description
Defines the intrusion state of all intrusion detection devices in this
chassis. The results are returned as a binary octet string. Each byte of
the octet string represents the status of a specific intrusion detection
device. The first byte returned represents the status of the first
intrusion detection device, the second byte returned represents the
status of the second intrusion detection device, and so on. The bytes
have the same definition type as DellStateSettings.
Syntax
Octet String (Size(1..128)
Access
Read-only
System State Chassis Intrusion Status Combined
Name
systemStateChassisIntrusionStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.30
Description
Defines the intrusion status of all intrusion detection devices in this
chassis. The result is returned as a combined status value. The value
has the same definition type as DellStatus.
Syntax
DellStatus
Access
Read-only
System State Chassis Intrusion Status Details
Name
systemStateChassisIntrusionStatusDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.31
Description
Defines the intrusion status of all intrusion detection devices in this
chassis. The first byte returned represents the status of the first
intrusion detection device, the second byte returned represents the
status of the second intrusion detection device, and so on.
Syntax
Octet String (Size(1..128))
Access
Read-only
System State Group
61
book.book Page 62 Wednesday, March 6, 2013 12:37 AM
System State AC Power Switch State Details
Name
systemStateACPowerSwitchStateDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.32
Description
Defines the individual state of all AC power switches in this chassis.
The first byte returned represents the state of the first AC power
switch, the second byte returned represents the state of the second
AC power switch, and so on.
Syntax
Octet String (Size(1..128))
Access
Read-only
System State AC Power Switch Status Redundancy
Name
systemStateACPowerSwitchStatusRedundancy
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.33
Description
Defines the overall redundancy status of the AC power switches in
this chassis.
Syntax
DellStatusRedundancy
Access
Read-only
System State AC Power Switch Status Details
Name
systemStateACPowerSwitchStatusDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.34
Description
Defines the individual status of all AC power switches in this
chassis. The first byte returned represents the status of the first
AC power switch, the second byte returned represents the status of
the second AC power switch, and so on.
Syntax
Octet String (Size(1..128))
Access
Read-only
62
System State Group
book.book Page 63 Wednesday, March 6, 2013 12:37 AM
System State AC Power Cord State Details
Name
systemStateACPowerCordStateDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.35
Description
Defines the individual state of all AC power cords for any AC power
switches in this chassis. The first byte returned represents the state
of the first AC power cord, the second byte returned represents the
state of the second AC power cord, and so on.
Syntax
Octet String (Size(1..128))
Access
Read-only
System State AC Power Cord Status Combined
Name
systemStateACPowerCordStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.36
Description
Defines the overall status of all AC power cords for any AC power
switches in this chassis.
Syntax
DellStatus
Access
Read-only
System State AC Power Cord Status Details
Name
systemStateACPowerCordStatusDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.37
Description
Defines the individual status of all AC power cords for any
AC power switches in this chassis. The first byte returned represents
the status of the first AC power cord, the second byte returned
represents the status of the second AC power cord, and so on.
Syntax
Octet String (SIZE(1..128))
Access
Read-only
System State Group
63
book.book Page 64 Wednesday, March 6, 2013 12:37 AM
System State Redundant Memory Unit State Details
Name
systemStateRedundantMemoryUnitStateDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.38
Description
Defines the state of all redundant memory units in this chassis.
The results are returned as a binary octet string, each byte of the
octet string represents the state of the specific object. The first byte
returned represents the state of the first object, and so on. The bytes
have the same definition type as DellStateSettings.
Syntax
Octet String (Size(1..128))
Access
Read-only
System State Redundant Memory Unit Status Redundancy
Name
systemStateRedundantMemoryUnitStatusRedundancy
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.39
Description
Defines the overall redundancy status for redundant memory.
Syntax
DellStatusRedundancy
Access
Read-only
System State Redundant Memory Unit Status Details
Name
systemStateRedundantMemoryUnitStatusDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.40
Description
Defines the status of all redundant memory units in this chassis.
The results are returned as a binary octet string, each byte of the
octet string represents the status of the specific object. The first
byte returned represents the status of the first object, and so on.
The bytes have the same definition type as DellStatusRedundancy.
Syntax
Octet String (Size(1..128))
Access
Read-only
64
System State Group
book.book Page 65 Wednesday, March 6, 2013 12:37 AM
System State Event Log Status
Name
systemStateEventLogStatus
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.41
Description
Defines the overall status of this chassis (ESM) event log.
Syntax
DellStatus
Access
Read-only
System State Power Unit Status Combined
Name
systemStatePowerUnitStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.42
Description
Defines the combined status of all power units of this chassis.
Syntax
DellStatus
Access
Read-only
System State Power Unit Status List
Name
systemStatePowerUnitStatusList
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.43
Description
Lists the status of each power unit of this chassis. The results are
returned as a binary octet string where each byte of the octet string
represents the status of a power unit. The first byte returned
represents the status of the first power unit, and so on. The bytes
have the same definition type as DellStatus.
Syntax
Octet String (Size(1..128))
Access
Read-only
System State Group
65
book.book Page 66 Wednesday, March 6, 2013 12:37 AM
System State Cooling Unit Status Combined
Name
systemStateCoolingUnitStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.44
Description
Defines the combined status of all cooling units of this chassis.
Syntax
DellStatus
Access
Read-only
System State Cooling Unit Status List
Name
systemStateCoolingUnitStatusList
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.45
Description
Lists the status of each cooling unit of this chassis. The results are
returned as a binary octet string where each byte of the octet string
represents the status of a cooling unit. The first byte returned
represents the status of the first cooling unit, and so on. The bytes
have the same definition type as DellStatus.
Syntax
Octet String (Size(1..128))
Access
Read-only
System State AC Power Switch Status Combined
Name
systemStateACPowerSwitchStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.46
Description
Defines the combined status of all AC power switches of this
chassis.
Syntax
DellStatus
Access
Read-only
66
System State Group
book.book Page 67 Wednesday, March 6, 2013 12:37 AM
System State AC Power Switch Status List
Name
systemStateACPowerSwitchStatusList
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.47
Description
Lists the status of each AC power switch of this chassis. The results
are returned as a binary octet string where each byte of the octet
string represents the status of an AC power switch. The first byte
returned represents the status of the first AC power switch, and so
on. The bytes have the same definition type as DellStatus.
Syntax
Octet String (Size(1..128))
Access
Read-only
System State Redundant Memory Unit Status Combined
Name
systemStateRedundantMemoryUnitStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.48
Description
Defines the combined status of all redundant memory units of this
chassis.
Syntax
DellStatus
Access
Read-only
System State Redundant Memory Unit Status List
Name
systemStateRedundantMemoryUnitStatusList
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.49
Description
Lists the status of each redundant memory unit of this chassis.
The results are returned as a binary octet string where each byte of
the octet string represents the status of a redundant memory unit.
The first byte returned represents the status of the first redundant
memory unit, and so on. The bytes have the same definition type as
DellStatus.
Syntax
Octet String (Size(1..128))
Access
Read-only
System State Group
67
book.book Page 68 Wednesday, March 6, 2013 12:37 AM
System State Processor Device Status Combined
Name
systemStateProcessorDeviceStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.50
Description
Defines the combined status of all processor devices of this chassis.
Syntax
DellStatus
Access
Read-only
System State Processor Device Status List
Name
systemStateProcessorDeviceStatusList
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.51
Description
Lists the status of each processor device of this chassis. The results
are returned as a binary octet string where each byte of the octet
string represents the status of a processor device. The first byte
returned represents the status of the first processor device, and so
on. The bytes have the same definition type as DellStatus.
Syntax
Octet String (Size(1..128))
Access
Read-only
System State Battery Status Combined
Name
systemStateBatteryStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.52
Description
Defines the combined status of all batteries of this chassis.
Syntax
DellStatus
Access
Read-only
System State Battery Status List
Name
systemStateBatteryStatusList
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.53
68
System State Group
book.book Page 69 Wednesday, March 6, 2013 12:37 AM
Name
systemStateBatteryStatusList
Description
Lists the status of each battery of this chassis. The results are
returned as a binary octet string where each byte of the octet string
represents the status of a battery. The first byte returned represents
the status of the first battery, and so on. The bytes have the same
definition type as DellStatus.
Syntax
Octet String (Size(1..128))
Access
Read-only
System State SD Card Unit Status Combined
Name
systemStateSDCardUnitStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.54
Description
Defines the combined status of all SD Card units of this chassis.
Syntax
DellStatus
Access
Read-only
System State SD Card Unit Status List
Name
systemStateSDCardUnitStatusList
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.55
Description
Lists the status of each SD Card unit of this chassis. The results are
returned as a binary octet string where each byte of the octet string
represents the status of a SD Card unit. The first byte returned
represents the status of the first SD Card unit, and so on. The bytes
have the same definition type as DellStatus.
Syntax
Octet String (Size(1..128))
Access
Read-only
System State SD Card Device Status Combined
Name
systemStateSDCardDeviceStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.56
Description
Defines the combined status of all SD Card devices of this chassis.
System State Group
69
book.book Page 70 Wednesday, March 6, 2013 12:37 AM
Name
systemStateSDCardDeviceStatusCombined
Syntax
DellStatus
Access
Read-only
System State SD Card Device Status List
Name
systemStateSDCardDeviceStatusList
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.57
Description
Lists the status of each SD Card device of this chassis. The results
are returned as a binary octet string where each byte of the octet
string represents the status of a SD Card device. The first byte
returned represents the status of the first SD Card device, and so on.
The bytes have the same definition type as DellStatus.
Syntax
Octet String (Size(1..128))
Access
Read-only
70
System State Group
book.book Page 71 Wednesday, March 6, 2013 12:37 AM
Chassis Information Group
5
The Chassis Information Group provides information about the type or types
of chassis in your system, as well as information about the light-emitting
diode (LED) indicators and settings for devices on each chassis. Information
is also available about the current date and time displayed on the chassis,
intrusion warnings, watchdog timer, systems management basic input/output
system (SMBIOS), and so on.
Chassis Information Group Tables
The following management information base (MIB) tables define the objects
in the Chassis Information Group:
•
"Chassis Information Table" on page 71
•
"UUID Table" on page 84
•
"POST Log Table" on page 86
•
"Event Log Table" on page 88
•
"System BIOS Table" on page 91
•
"Firmware Table" on page 98
•
"Intrusion Table" on page 101
•
"Baseboard Table" on page 103
Chassis Information Table
The following object sets up the Chassis Information Table.
Name
chassisInformationTable
Object ID
1.3.6.1.4.1.674.10892.1.300.10
Description
Defines the chassis information table.
Syntax
SEQUENCE OF ChassisInformationTableEntry
Access
Not accessible
Chassis Information Group
71
book.book Page 72 Wednesday, March 6, 2013 12:37 AM
Chassis Information Table Entry
Name
chassisInformationTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1
Description
Defines the chassis information table entry.
Syntax
ChassisInformationTableEntry
Access
Not accessible
Index
chassisIndexChassisInformation
Chassis Index Chassis Information
Name
chassisIndexChassisInformation
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.1
Description
Defines the index (one-based) of this chassis. The first chassis is
numbered one.
Syntax
DellObjectRange
Access
Read-only
Chassis State Capabilities
Name
chassisStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.2
Description
Defines the capabilities of the chassis.
Syntax
DellStateCapabilities
Access
Read-only
Chassis State Settings
Name
chassisStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.3
Description
Defines the state settings for the chassis.
Syntax
DellStateSettings
Access
Read-write
72
Chassis Information Group
book.book Page 73 Wednesday, March 6, 2013 12:37 AM
Chassis Status
Name
chassisStatus
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.4
Description
Defines the status of the chassis.
Syntax
DellStatus
Access
Read-only
Chassis Parent Index Reference
Name
chassisparentIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.4
Description
Defines the index (one-based) of the parent chassis of this
chassis, if any. A zero (0) means that this chassis is the parent of
all other chassis managed by the Server Administrator.
Syntax
DellObjectRange
Access
Read-only
Chassis Type
Name
chassisType
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.6
Description
Defines the chassis type.
Syntax
DellChassisType (See Table 6-2)
Access
Read-only
Chassis Name
Name
chassisName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.7
Description
Defines the user-assigned chassis name of the chassis.
Syntax
DellString
Access
Read-write
Chassis Information Group
73
book.book Page 74 Wednesday, March 6, 2013 12:37 AM
Chassis Manufacturer Name
Name
chassisManufacturerName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.8
Description
Defines the manufacturer’s name for this chassis.
Syntax
DellString
Access
Read-only
Chassis Model Name
Name
chassisModelName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.9
Description
Defines the system model type for this chassis.
Syntax
DellString
Access
Read-only
Chassis Asset Tag Name
Name
chassisAssetTagName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.10
Description
Defines the user-assigned asset tag name for this chassis.
Syntax
DisplayString (SIZE (0..10))
Access
Read-write
Chassis Service Tag Name
Name
chassisServiceTagName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.11
Description
Defines the service tag name for this chassis.
Syntax
DisplayString (SIZE (0..7))
Access
Read-only
74
Chassis Information Group
book.book Page 75 Wednesday, March 6, 2013 12:37 AM
Chassis ID
Name
chassisID
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.12
Description
Defines the asset tag name for this chassis.
Syntax
DellUnsigned8BitRange
Access
Read-only
Chassis ID Extension
Name
chassisIDExtension
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.13
Description
Defines the SMBIOS machine ID of this chassis.
Syntax
DellUnsigned16BitRange
Access
Read-only
Chassis System Class
Name
chassisSystemClass
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.14
Description
Defines the chassis class of this chassis.
Syntax
DellChassisSystemClass (See Table 6-21)
Access
Read-only
Chassis System Name
Name
chassisSystemName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.15
Description
Defines the system name of this chassis.
Syntax
DellString
Access
Read-only
Chassis Information Group
75
book.book Page 76 Wednesday, March 6, 2013 12:37 AM
Chassis System Boot Date Name
Name
chassisSystemBootDateName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.16
Description
Defines the boot time of this system.
Syntax
DellDateName
Access
Read-only
Chassis System Date Name
Name
chassisSystemDateName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.17
Description
Defines the current time on this system.
Syntax
DellDateName
Access
Read-only
Chassis System Location Name
Name
chassisSystemLocationName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.18
Description
Defines the user-assigned location for this chassis.
Syntax
DellString
Access
Read-write
Chassis System Primary User Name
Name
chassisSystemPrimaryUserName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.19
Description
Defines the user-assigned primary user name for this chassis.
Syntax
DellString
Access
Read-write
76
Chassis Information Group
book.book Page 77 Wednesday, March 6, 2013 12:37 AM
Chassis System User Phone Number Name
Name
chassisSystemUserPhoneNumberName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.20
Description
Defines the user-assigned phone number of the primary user of
the system.
Syntax
DellString
Access
Read-write
Chassis Connection Status Unique
Name
chassisConnectionStatusUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.21
Description
Defines the status of the connection from the system chassis to
an expansion chassis.
Syntax
DellConnectionStatus (See Table 6-3)
Access
Read-only
Chassis Fan Control Capabilities Unique
Name
chassisFanControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.22
Description
Defines the capabilities of the fan control function in this chassis.
Syntax
DellFanControlCapabilities (See Table 6-4)
Access
Read-only
Chassis Fan Control Settings Unique
Name
chassisFanControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.23
Description
Defines the readings and settings of the fan control hardware in
the chassis.
Syntax
DellFanControlSettings
Access
Read-write
Chassis Information Group
77
book.book Page 78 Wednesday, March 6, 2013 12:37 AM
Chassis LED Control Capabilities Unique
Name
chassisLEDControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.24
Description
Defines the capabilities of the LED control function in the chassis.
Syntax
DellLEDControlCapabilities (See Table 6-5)
Access
Read-only
Chassis LED Control Settings Unique
Name
chassisLEDControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.25
Description
Defines the readings and settings of the LED control hardware
in the chassis.
Syntax
DellLEDControlSettings (See Table 6-6)
Access
Read-write
Chassis Hard-Drive (HD) Fault Clear Control Capabilities
Name
chassisHDFaultClearControlCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.26
Description
Specifies whether the chassis allows reset of the chassis
hard-drive fault LED.
Syntax
DellHDFaultLEDControlCapabilities (See Table 6-7)
Access
Read-only
Chassis HD Fault Clear Control Settings
Name
chassisHDFaultClearControlSettings
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.27
Description
Allows reset of the chassis hard-drive fault LED.
Syntax
DellHDFaultLEDControlSettings (See Table 6-8)
Access
Read-write
78
Chassis Information Group
book.book Page 79 Wednesday, March 6, 2013 12:37 AM
Chassis Identify Flash Control Capabilities
Name
chassisIdentifyFlashControlCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.28
Description
Specifies whether the chassis front-panel LED can be set to flash.
Syntax
DellChassisIdentifyControlCapabilities (See Table 6-9)
Access
Read-only
Chassis Identify Flash Control Settings
Name
chassisIdentifyFlashControlSettings
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.29
Description
Causes the chassis front-panel LED to flash.
Syntax
DellChassisIdentifyControlSettings (See Table 6-10)
Access
Read-write
Chassis Lock Present
Name
chassisLockPresent
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.30
Description
Specifies whether a chassis lock is present on the chassis.
Syntax
DellBoolean
Access
Read-only
Chassis Host Control Capabilities Unique
Name
chassishostControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.31
Description
Defines the capabilities of the host control object.
Syntax
DellHostControlCapabilities (See Table 6-11)
Access
Read-only
Chassis Information Group
79
book.book Page 80 Wednesday, March 6, 2013 12:37 AM
Chassis Host Control Settings Unique
Name
chassishostControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.32
Description
Defines the current settings of the host control object.
Syntax
DellHostControlSettings (See Table 6-12)
Access
Read-write
Chassis Watchdog Control Capabilities Unique
Name
chassiswatchDogControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.33
Description
Defines the capabilities of the watchdog timer object.
Syntax
DellWatchDogControlCapabilities (See Table 6-13)
Access
Read-only
Chassis Watchdog Control Settings Unique
Name
chassiswatchDogControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.34
Description
Defines the current settings and the values allowed to be set for
the watchdog timer object.
Syntax
DellWatchDogControlCapabilities (See Table 6-13)
Access
Read-write
Chassis Watchdog Control Expiry Time Capabilities Unique
Name
chassiswatchDogControlExpiryTimeCapabilities
Unique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.35
Description
Defines the capabilities of the watchdog expiry timer object.
Syntax
DellWatchDogTimerCapabilities (See Table 6-13)
Access
Read-only
80
Chassis Information Group
book.book Page 81 Wednesday, March 6, 2013 12:37 AM
Chassis Watchdog Control Expiry Time
Name
chassiswatchDogControlExpiryTime
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.36
Description
Defines the current reading and allows setting of the nonrecoverable
watchdog expiry timer object.
Syntax
DellUnsigned16BitRange
Access
Read-write
Chassis Allow Set Commands From SNMP
Name
chassisallowSETCommandsfromSNMP
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.37
Description
Specifies whether Simple Network Management Protocol (SNMP)
Set type commands are allowed by Server Administrator.
This attribute does not reflect whether SNMP Set type commands
are allowed by the SNMP master agent.
Syntax
DellBoolean
Access
Read-only
Chassis Power Button Control Capabilities Unique
Name
chassisPowerButtonControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.38
Description
Defines the capabilities of the power button control function.
Syntax
DellPowerButtonControlCapabilities (See Table 6-16)
Access
Read-only
Chassis Power Button Control Settings Unique
Name
chassisPowerButtonControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.39
Description
Defines the current reading and allows setting of the power button
control hardware.
Chassis Information Group
81
book.book Page 82 Wednesday, March 6, 2013 12:37 AM
Name
chassisPowerButtonControlSettingsUnique
Syntax
DellPowerButtonControlSettings (See Table 6-17)
Access
Read-write
Chassis Reseller Name
Name
chassisResellerName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.40
Description
Defines the name of the chassis reseller.
Syntax
DisplayString (SIZE (0..128))
Access
Read-only
Chassis Reseller Contact Information Name
Name
chassisResellerContactInformationName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.41
Description
Defines the chassis reseller contact information name.
Syntax
DisplayString (SIZE (0..128))
Access
Read-only
Chassis Reseller Product Name
Name
chassisResellerProductName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.42
Description
Defines the chassis reseller product name.
Syntax
DisplayString (SIZE (0..128))
Access
Read-only
Chassis Reseller System ID
Name
chassisResellerSystemID
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.43
Description
Defines the chassis reseller system ID.
82
Chassis Information Group
book.book Page 83 Wednesday, March 6, 2013 12:37 AM
Name
chassisResellerSystemID
Syntax
DellUnsigned16BitRange
Access
Read-only
Chassis NMI Button Control Capabilities Unique
Name
chassisNMIButtonControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.44
Description
Defines the capabilities of the NMI button control function.
Syntax
DellNMIButtonControlCapabilities (See Table 6-18)
Access
Read-only
Chassis NMI Button Control Settings Unique
Name
chassisNMIButtonControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.45
Description
Defines the current reading and allows setting of the NMI button
control hardware.
Syntax
DellNMIButtonControlSettings (See Table 6-19)
Access
Read-write
Chassis System Properties
Name
chassisSystemProperties
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.46
Description
Defines the properties of the system.
Syntax
DellSystemProperties (See Table 6-20)
Access
Read-only
Chassis Information Group
83
book.book Page 84 Wednesday, March 6, 2013 12:37 AM
Chassis System Revision Number
Name
chassisSystemRevisionNumber
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.47
Description
Defines the revision number of the system where zero indicates the
original version of the system. The revision number is not available
on all systems.
Syntax
DellUnsigned8BitRange
Access
Read-only
Chassis System Revision Name
Name
chassisSystemRevisionName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.48
Description
Defines the revision name of the system, if applicable.
Syntax
DellString
Access
Read-only
Chassis Express Service Code Name
Name
chassisExpressServiceCodeName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.49
Description
Defines the express service code of the chassis.
Syntax
DellString
Access
Read-only
UUID Table
These objects comprise the server administrator definitions for the
Universal Unique Identifier (UUID).
Name
uUIDTable
Object ID
1.3.6.1.4.1.674.10892.1.300.20
Description
Defines the UUID table.
Syntax
SEQUENCE OF UUIDTableEntry
84
Chassis Information Group
book.book Page 85 Wednesday, March 6, 2013 12:37 AM
Name
uUIDTable
Access
Not accessible
UUID Table Entry
Name
uUIDTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.300.20.1
Description
Defines the UUID table entry.
Syntax
UUIDTableEntry
Access
Not accessible
Index
uUIDIndex, uUIDchassisIndex
UUID Chassis Index
Name
uUIDchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.20.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
UUID Index
Name
uUIDIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.20.1.2
Description
Defines the index of the UUID in a specified chassis.
Syntax
DellObjectRange
Access
Read-only
UUID Type
Name
uUIDType
Object ID
1.3.6.1.4.1.674.10892.1.300.20.1.3
Description
Defines the type of the UUID for this chassis.
Chassis Information Group
85
book.book Page 86 Wednesday, March 6, 2013 12:37 AM
Name
uUIDType
Syntax
DellUUIDType
Access
Read-only
UUID Value
Name
uUIDValue
Object ID
1.3.6.1.4.1.674.10892.1.300.20.1.4
Description
Defines the value of the UUID for this chassis.
Syntax
Octet String (SIZE(16))
Access
Read-only
POST Log Table
This section defines attributes for the power-on self-test (POST) log.
When you turn on your computer, the POST checks various system
components before the operating system loads. The POST tests the
random-access memory (RAM), the hard drives, and the keyboard,
for example. While the POST is running, it makes a log file that system
administrators can view. The variables in this section also contribute to
managing the POST log.
Name
postLogTable
Object ID
1.3.6.1.4.1.674.10892.1.300.30
Description
Defines the POST Log Table.
Syntax
SEQUENCE OF PostLogTableEntry
Access
Not accessible
POST Log Table Entry
Name
postLogTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.300.30.1
Description
Defines the POST Log Table entry.
Syntax
PostLogTableEntry
86
Chassis Information Group
book.book Page 87 Wednesday, March 6, 2013 12:37 AM
Name
postLogTableEntry
Access
Not accessible
Index
postLogchassisIndex, postLogRecordIndex
POST Log Chassis Index
Name
postLogchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.30.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
POST Log Record Index
Name
postLogRecordIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.30.1.2
Description
Defines the record number (one-based) of the POST log.
Syntax
DellUnsigned32BitRange
Access
Read-only
POST Log State Capabilities Unique
Name
postLogStateCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.30.1.3
Description
Defines the capabilities of the object that is writing the POST log.
Syntax
DellStateCapabilitiesLogUnique
Access
Read-only
POST Log State Settings Unique
Name
postLogStateSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.30.1.4
Description
Defines the state of the object that is writing the POST log.
Chassis Information Group
87
book.book Page 88 Wednesday, March 6, 2013 12:37 AM
Name
postLogStateSettingsUnique
Syntax
DellStateSettingsLogUnique
Access
Read-write
POST Log Record
Name
postLogRecord
Object ID
1.3.6.1.4.1.674.10892.1.300.30.1.5
Description
Defines the data for the specified chassis and record index in the
POST log being returned.
Syntax
DisplayString (SIZE (0..1024))
Access
Read-only
POST Log Format
Name
postLogFormat
Object ID
1.3.6.1.4.1.674.10892.1.300.30.1.5
Description
Defines format of the POST log.
Syntax
DellLogFormat (See Table 6-1)
Access
Read-only
Event Log Table
Name
eventLogTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.300.40
Description
Defines the Event Log Table.
Syntax
SEQUENCE OF EventLogTableEntry
Access
Not accessible
Event Log Table Entry
Name
eventLogTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.300.40.1
88
Chassis Information Group
book.book Page 89 Wednesday, March 6, 2013 12:37 AM
Name
eventLogTableEntry
Description
Defines the event Log Table Entry.
Syntax
EventLogTableEntry
Access
Not accessible
Index
eventLogchassisIndex,eventLogRecordIndex
Event Log Chassis Index
Name
eventLogchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.40.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Event Log Record Index
Name
eventLogRecordIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.40.1.2
Description
Defines the record index of the event log.
Syntax
DellUnsigned32BitRange
Access
Read-only
Event Log State Capabilities Unique
Name
eventLogStateCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.40.1.3
Description
Defines the capabilities of the object that is writing the event log.
Syntax
DellStateCapabilitiesLogUnique
Access
Read-only
Chassis Information Group
89
book.book Page 90 Wednesday, March 6, 2013 12:37 AM
Event Log State Settings Unique
Name
eventLogStateSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.40.1.4
Description
Defines the state settings for the object that is writing the event log.
Syntax
DellStateSettingsLogUnique
Access
Read-write
Event Log Record
Name
eventLogRecord
Object ID
1.3.6.1.4.1.674.10892.1.300.40.1.5
Description
Defines the data for the specified chassis and log record index in the
event log being returned.
Syntax
DisplayString (SIZE (0..1024))
Access
Read-only
Event Log Format
Name
eventLogFormat
Object ID
1.3.6.1.4.1.674.10892.1.300.40.1.6
Description
Defines the format of the event log.
Syntax
DellLogFormat (See Table 6-1)
Access
Read-only
Event Log Severity Status
Name
eventLogSeverityStatus
Object ID
1.3.6.1.4.1.674.10892.1.300.40.1.7
Description
Defines the severity of the event log record.
Syntax
DellStatus
Access
Read-only
Status
Mandatory
90
Chassis Information Group
book.book Page 91 Wednesday, March 6, 2013 12:37 AM
Event Log Date Name
Name
eventLogDateName
Object ID
1.3.6.1.4.1.674.10892.1.300.40.1.8
Description
Defines the date and time of the event log record.
Syntax
DellDateName
Access
Read-only
Status
Mandatory
System BIOS Table
This table lists objects that define the system’s basic input/output system (BIOS).
Name
systemBIOSTable
Object ID
1.3.6.1.4.1.674.10892.1.300.50
Description
Defines the System BIOS Table.
Syntax
SEQUENCE OF SystemBIOSTableEntry
Access
Not accessible
System BIOS Table Entry
Name
systemBIOSTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1
Description
Defines the System BIOS Table entry.
Syntax
SystemBIOSTableEntry
Access
Not accessible
Index
systemBIOSchassisIndex,systemBIOSIndex
System BIOS Chassis Index
Name
systemBIOSchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Chassis Information Group
91
book.book Page 92 Wednesday, March 6, 2013 12:37 AM
Name
systemBIOSchassisIndex
Access
Read-only
System BIOS Index
Name
systemBIOSIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.2
Description
Defines the index (one-based) of the system BIOS of this object.
Syntax
DellObjectRange
Access
Read-only
System BIOS State Capabilities
Name
systemBIOSStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.3
Description
Defines the capabilities of the system BIOS of this object.
Syntax
DellStateCapabilities
Access
Read-only
System BIOS State Settings
Name
systemBIOSStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.4
Description
Defines the state of the system BIOS of this object.
Syntax
DellStateSettings
Access
Read-write
System BIOS Status
Name
systemBIOSStatus
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.5
Description
Defines the status of the system BIOS of this object.
Syntax
DellStatus
92
Chassis Information Group
book.book Page 93 Wednesday, March 6, 2013 12:37 AM
Name
systemBIOSStatus
Access
Read-only
System BIOS Size
Name
systemBIOSSize
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.6
Description
Defines the image size of the system BIOS in kilobytes (KB).
A zero (0) indicates that the image size of the BIOS is unknown.
Syntax
DellUnsigned32BitRange
Access
Read-only
System BIOS Release Date Name
Name
systemBIOSReleaseDateName
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.7
Description
Defines the release date of the system BIOS.
Syntax
DellDateName
Access
Read-only
System BIOS Version Name
Name
systemBIOSVersionName
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.8
Description
Defines the version name of the system BIOS.
Syntax
DellString
Access
Read-only
System BIOS Starting Address
Name
systemBIOSStartingAddress
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.9
Chassis Information Group
93
book.book Page 94 Wednesday, March 6, 2013 12:37 AM
Name
systemBIOSStartingAddress
Description
Defines the starting address of the system BIOS. A zero (0) indicates
that the address is unknown.
Syntax
DellUnsigned64BitRange
Access
Read-only
System BIOS Ending Address
Name
systemBIOSEndingAddress
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.10
Description
Defines the ending address of the system BIOS. A zero (0) indicates
that the address is unknown.
Syntax
DellUnsigned64BitRange
Access
Read-only
System BIOS Manufacturer Name
Name
systemBIOSManufacturerName
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.11
Description
Defines the system BIOS manufacturer’s name.
Syntax
DellString
Access
Read-only
System BIOS Characteristics
Name
systemBIOSCharacteristics
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.12
94
Chassis Information Group
book.book Page 95 Wednesday, March 6, 2013 12:37 AM
Name
systemBIOSCharacteristics
Description
Defines characteristics of the system BIOS. This attribute is a bit
field where a bit has the meaning defined below when set to 1 (one).
Bit 63 is the first bit in the value, and bit 0 is the last bit in the value.
See the description of DellUnsigned64BitRange at the beginning of
this file for more information on the format of the value.
Bits 48-63 need to be examined in the context of the system ID.
The system ID is available in the attribute chassisID. If the value for
chassisID is non-zero, bits 48-63 have the meaning defined below:
Bit Position Meaning if Set
-------------- -----------------Bit 0Reserved
Bit 1Reserved
Bit 2Unknown
Bit 3BIOS Characteristics Not Supported
Bit 4ISA is supported
Bit 5MCA is supported
Bit 6EISA is supported
Bit 7PCI is supported
Bit 8PC Card (PCMCIA) is supported
Bit 9Plug and Play is supported
Bit 10APM is supported
Bit 11BIOS is Upgradeable (Flash)
Bit 12BIOS shadowing is allowed
Bit 13VL-VESA is supported
Bit 14ESCD support is available
Bit 15Boot from CD is supported
Chassis Information Group
95
book.book Page 96 Wednesday, March 6, 2013 12:37 AM
Name
systemBIOSCharacteristics
Description
Bit Position Meaning if Set
-------------- -----------------Bit 16Selectable Boot is supported
Bit 17BIOS ROM is socketed
Bit 18Boot From PC Card (PCMCIA) is supported
Bit 19EDD (Enhanced Disk Drive) Specification is supported
Bit 20Int 13h - Japanese Floppy for NEC 9800 1.2mb (3.5 in,
1k Bytes/Sector, 360 RPM) is supported
Bit 21Int 13h - Japanese Floppy for Toshiba 1.2mb (3.5 in,
360 RPM) is supported
Bit 22Int 13h - 5.25 in / 360 KB Floppy Services are supported
Bit 23Int 13h - 5.25 in /1.2MB Floppy Services are supported
Bit 24Int 13h - 3.5 in / 720 KB Floppy Services are supported
Bit 25Int 13h - 3.5 in / 2.88 MB Floppy Services are supported
Bit 26Int 5h, Print Screen Service is supported
Bit 27Int 9h, 8042 Keyboard services are supported
Bit 28Int 14h, Serial Services are supported
Bit 29Int 17h, Printer Services are supported
Bit 30Int 10h, CGA/Mono Video Services are supported
Bit 31NEC PC-98
Bit 32-47Reserved
Bit 48Built-in NIC supports Magic Packet
Bit 49System supports Wake-on-LAN
Bit 50System supports chassis intrusion
Bit 51Built-in NIC supports pattern-matching
Bit 52System BIOS supports a 7-character service tag
Bit 53-63Reserved
Syntax
DellUnsigned64BitRange
System BIOS Characteristics Ext 1
Name
systemBIOSCharacteristicsExt1
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.13
96
Chassis Information Group
book.book Page 97 Wednesday, March 6, 2013 12:37 AM
Name
systemBIOSCharacteristicsExt1
Description
Defines additional characteristics of the system basic input/output
system (BIOS). This attribute is a bit field where a bit has the
meaning defined below when set to 1 (one).
Bit Position Meaning if Set
-------------- -----------------Bit 0ACPI supported
Bit 1USB Legacy is supported
Bit 2AGP is supported
Bit 3I2O boot is supported
Bit 4LS-120 boot is supported
Bit 5ATAPI ZIP Drive boot is supported
Bit 61394 boot is supported
Bit 7Smart Battery supported
Syntax
DellUnsigned8BitRange
Access
Read-only
System BIOS Characteristics Ext 2
Name
systemBIOSCharacteristicsExt2
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.14
Description
Defines additional characteristics of the system BIOS.
This attribute is a bit field where a bit has the meaning defined
below when set to 1 (one).
Bit Position Meaning if Set
--------------- -------------------Bit 0BIOS Boot Specification supported
Bit 1Function key-initiated Network Service boot supported
Bit 2Targeted Content Distribution supported
Bit 3-7Reserved
Syntax
DellUnsigned8BitRange
Access
Read-only
Chassis Information Group
97
book.book Page 98 Wednesday, March 6, 2013 12:37 AM
Firmware Table
Name
firmwareTable
Object ID
1.3.6.1.4.1.674.10892.1.300.60
Description
Defines the Firmware Table.
Syntax
SEQUENCE OF FirmwareTableEntry
Access
Not accessible
Firmware Table Entry
Name
firmwareTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.300.60.1
Description
Defines the Firmware Table entry.
Syntax
FirmwareTableEntry
Access
Not accessible
Index
firmwarechassisIndex, firmwareIndex
Firmware Chassis Index
Name
firmwarechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.60.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Firmware Index
Name
firmwareIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.60.1.2
Description
Defines the index (one-based) of the firmware in this chassis.
Syntax
DellObjectRange
Access
Read-only
98
Chassis Information Group
book.book Page 99 Wednesday, March 6, 2013 12:37 AM
Firmware State Capabilities
Name
firmwareStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.300.60.1.3
Description
Defines the capabilities of the firmware states.
Syntax
DellStateCapabilities
Access
Read-only
Firmware State Capabilities
Name
firmwareStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.300.60.1.4
Description
Defines the state of the firmware and allows for the setting of the
firmware.
Syntax
DellStateSettings
Access
Read-write
Firmware Status
Name
firmwareStatus
Object ID
1.3.6.1.4.1.674.10892.1.300.60.1.5
Description
Defines the status of the firmware.
Syntax
DellStateSettings
Access
Read-only
Firmware Size
Name
firmwareSize
Object ID
1.3.6.1.4.1.674.10892.1.300.60.1.6
Description
Defines the image size of the firmware in KB. A zero (0) indicates
that the size is unknown.
Syntax
DellUnsigned16BitRange
Access
Read-only
Chassis Information Group
99
book.book Page 100 Wednesday, March 6, 2013 12:37 AM
Firmware Type
Name
firmwareType
Object ID
1.3.6.1.4.1.674.10892.1.300.60.1.7
Description
Defines the type of the firmware.
Syntax
DellFirmwareType
Access
Read-only
Firmware Type Name
Name
firmwareTypeName
Object ID
1.3.6.1.4.1.674.10892.1.300.60.1.8
Description
Defines the name of firmware type.
Syntax
DellString
Access
Read-only
Firmware Update Capabilities
Name
firmwareUpdateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.300.60.1.9
Description
Defines the bitmap of supported methods for firmware update.
Syntax
DellUnsigned16BitRange
Access
Read-only
Firmware Date Name
Name
firmwareDateName
Object ID
1.3.6.1.4.1.674.10892.1.300.60.1.10
Description
Defines the date of the firmware.
Syntax
DellDateName
Access
Read-only
100
Chassis Information Group
book.book Page 101 Wednesday, March 6, 2013 12:37 AM
Firmware Version Name
Name
firmwareVersionName
Object ID
1.3.6.1.4.1.674.10892.1.300.60.1.11
Description
Defines the version name of the firmware.
Syntax
DellString
Access
Read-only
Intrusion Table
The following objects and attributes describe the different forms of chassis
intrusion, a situation that occurs when the cover of a computer is removed.
Name
intrusionTable
Object ID
1.3.6.1.4.1.674.10892.1.300.70
Description
Defines the Intrusion Table.
Syntax
SEQUENCE OF IntrusionTableEntry
Access
Not accessible
Intrusion Table Entry
Name
intrusionTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.300.70.1
Description
Defines the Intrusion Table entry.
Syntax
IntrusionTableEntry
Access
Not accessible
Index
intrusionchassisIndex, intrusionIndex
Intrusion Chassis Index
Name
intrusionchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.70.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Chassis Information Group
101
book.book Page 102 Wednesday, March 6, 2013 12:37 AM
Intrusion Index
Name
intrusionIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.70.1.2
Description
Defines the index of the intrusion objects in this subgroup.
Syntax
DellObjectRange
Access
Read-only
Intrusion State Capabilities
Name
intrusionStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.300.70.1.3
Description
Defines the capabilities of the intrusion object.
Syntax
DellStateCapabilities
Access
Read-only
Intrusion State Settings
Name
intrusionStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.300.70.1.4
Description
Defines the settings of the intrusion object.
Syntax
DellStateSettings
Access
Read-write
Intrusion Status
Name
intrusionStatus
Object ID
1.3.6.1.4.1.674.10892.1.300.70.1.5
Description
Defines the status of the intrusion object.
Syntax
DellStatus
Access
Read-only
102
Chassis Information Group
book.book Page 103 Wednesday, March 6, 2013 12:37 AM
Intrusion Reading
Name
intrusionReading
Object ID
1.3.6.1.4.1.674.10892.1.300.70.1.6
Description
Defines the reading of the intrusion object.
Syntax
DellIntrusionReading
Access
Read-only
Intrusion Type
Name
intrusionType
Object ID
1.3.6.1.4.1.674.10892.1.300.70.1.7
Description
Defines the type of the intrusion object.
Syntax
DellIntrusionType
Access
Read-only
Intrusion Location Name
Name
intrusionLocationName
Object ID
1.3.6.1.4.1.674.10892.1.300.70.1.8
Description
Defines the location name of the intrusion object in this subgroup.
Syntax
DellString
Access
Read-only
Baseboard Table
This table lists objects that define the baseboard of a system.
Name
baseBoardTable
Object ID
1.3.6.1.4.1.674.10892.1.300.80
Description
Defines the Baseboard Table.
Syntax
SEQUENCE OF BaseBoardTableEntry
Access
Not accessible
Chassis Information Group
103
book.book Page 104 Wednesday, March 6, 2013 12:37 AM
Baseboard Table Entry
Name
baseBoardTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1
Description
Defines the Baseboard Table entry.
Syntax
BaseBoardTableEntry
Access
Not accessible
Index
baseBoardChassisIndex, baseBoardIndex
Baseboard Chassis Index
Name
baseBoardChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.1
Description
Defines the index (one-based) of the associated chassis.
Syntax
DellObjectRange
Access
Read-only
Baseboard Index
Name
baseBoardIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.2
Description
Defines the index (one-based) of the base board.
Syntax
DellObjectRange
Access
Read-only
Baseboard State Capabilities
Name
baseBoardStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.3
Description
Defines the state capabilities of the baseboard.
Syntax
DellStateCapabilities
Access
Read-only
104
Chassis Information Group
book.book Page 105 Wednesday, March 6, 2013 12:37 AM
Baseboard State Settings
Name
baseBoardStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.4
Description
Defines the state settings of the baseboard.
Syntax
DellStateSettings
Access
Read-write
Baseboard Status
Name
baseBoardStatus
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.5
Description
Defines the status of the baseboard.
Syntax
DellStatus
Access
Read-only
Baseboard Feature Flags
Name
baseBoardFeatureFlags
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.6
Description
Defines the features of the baseboard.
Syntax
DellBaseBoardFeatureFlags
Access
Read-only
Baseboard Type
Name
baseBoardType
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.7
Description
Defines the type of the baseboard.
Syntax
DellBaseBoardType
Access
Read-only
Chassis Information Group
105
book.book Page 106 Wednesday, March 6, 2013 12:37 AM
Baseboard Type Name
Name
baseBoardTypeName
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.8
Description
Defines the name of the type of baseboard.
Syntax
DellString
Access
Read-only
Baseboard Location Name
Name
baseBoardLocationName
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.9
Description
Defines the location name of the baseboard.
Syntax
DellString
Access
Read-only
Baseboard Manufacturer Name
Name
baseBoardManufacturerName
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.10
Description
Defines the baseboard manufacturer’s name.
Syntax
DellString
Access
Read-only
Baseboard Product Name
Name
baseBoardProductName
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.11
Description
Defines the baseboard product’s name.
Syntax
DellString
Access
Read-only
106
Chassis Information Group
book.book Page 107 Wednesday, March 6, 2013 12:37 AM
Baseboard Version Name
Name
baseBoardVersionName
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.12
Description
Defines the baseboard version name.
Syntax
DellString
Access
Read-only
Baseboard Service Tag Name
Name
baseBoardServiceTagName
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.13
Description
Defines the baseboard service tag name.
Syntax
DellString
Access
Read-only
Baseboard Piece Part ID (PPID) Name
Name
baseBoardPiecePartIDName
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.14
Description
Defines the baseboard PPID.
Syntax
DellString
Access
Read-only
Baseboard Asset Tag Name
Name
baseBoardAssetTagName
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.15
Description
Defines the baseboard asset tag name.
Syntax
DellString
Access
Read-only
Chassis Information Group
107
book.book Page 108 Wednesday, March 6, 2013 12:37 AM
Baseboard Express Service Code Name
Name
baseBoardExpressServiceCodeName
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.16
Description
Defines the express service code of the baseboard.
Syntax
DellString
Access
Read-only
Chassis Information Group Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 5-1. Log Format
Variable Name: DellLogFormat
Data Type: Integer
Possible Data Values
Meaning of Data Value
raw(1)
The log is in the format received from the
firmware.
ascii(2)
The log is in ASCII format.
uniCode(3)
The log is in Unicode format.
Table 5-2. Chassis Type
Variable Name: DellChassisType
Data Type: Integer
Possible Data Values
Meaning of Data Value
other(1)
The chassis type is not one of the following:
unknown(2)
The chassis type is unknown.
desktop(3)
The chassis type is a desktop.
lowProfileDesktop(4)
The chassis type is a low-profile desktop.
pizzaBox(5)
The chassis type is a pizza box.
miniTower(6)
The chassis type is a minitower.
108
Chassis Information Group
book.book Page 109 Wednesday, March 6, 2013 12:37 AM
Table 5-2. Chassis Type (continued)
Variable Name: DellChassisType
Data Type: Integer
Possible Data Values
Meaning of Data Value
tower(7)
The chassis type is a tower.
portable(8)
The chassis type is a portable.
lapTop(9)
The chassis type is a laptop.
noteBook(10)
The chassis type is a notebook.
handHeld(11)
The chassis type is a handheld.
dockingStation(12)
The chassis type is a docking station.
allInOne(13)
The chassis type is an all-in-one.
subNoteBook(14)
The chassis type is a subnotebook.
spaceSaving(15)
The chassis type is a spacesaver.
lunchBox(16)
The chassis type is a lunch box.
mainSystemChassis(17)
The chassis type is the main system chassis.
expansionChassis(18)
The chassis type is an expansion chassis.
subChassis(19)
The chassis type is a subchassis.
busExpansionChassis(20)
The chassis type is a bus-expansion chassis.
peripheralChassis(21)
The chassis type is a peripheral chassis.
raidChassis(22)
The chassis type is a disk RAID chassis.
rackMountChassis(23)
The chassis type is a rack-mounted chassis.
sealedCasePC(24)
The chassis type is a sealed-case chassis.
multiSystemChassis(25)
The chassis type is a multisystem chassis.
Chassis Information Group
109
book.book Page 110 Wednesday, March 6, 2013 12:37 AM
Table 5-3. Connection Status
Variable Name: DellConnectionStatus
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(2)
The status of the chassis connection is
unknown.
ok(3)
The status of the chassis connection is OK.
failure(4)
The status of the chassis connection is
failure.
Table 5-4. Fan Control Capabilities
Variable Name: DellFanControlCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
The fan’s capabilities are unknown.
lowSpeedCapable(2)
The fan can be set to low speed.
highSpeedCapable(4)
The fan can be set to high speed.
lowOrhighSpeedCapable(6)
The fan can be set to low or high speed.
Table 5-5. Front-Panel LED Control Capabilities
Variable Name: DellLEDControlCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
The LED control capabilities are unknown.
alertOnErrorCapable(2)
The LED control can be set to alert on an
error condition.
alertOnWarningAndErrorCap The LED control can be set to alert on an
able(4)
error and a warning condition.
alertOnWarningOrErrorCapa The LED control can be set to alert on an
ble(6)
error or a warning condition.
110
Chassis Information Group
book.book Page 111 Wednesday, March 6, 2013 12:37 AM
Table 5-6. Front-Panel LED Control Settings
Variable Name: DellLEDControlSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
The LED control setting is unknown.
alertOnError(2)
The LED control is set to alert on an error
condition.
alertOnWarningAndError(4) The LED control is set to alert on an error or
a warning condition.
Table 5-7. Hard-Drive Fault LED Control Capabilities
Variable Name: DellHDFaultLEDControlCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The hard drive has no fault LED
capabilities.
unknownCapabilities(1)
The hard-drive fault LED capabilities are
unknown.
enableCapable(2)
The hard-drive fault LED can be disabled
(offline, a binary 0 value) or enabled (online,
a binary 1 value).
notReadyCapable(4)
The hard-drive fault LED can indicate not
ready.
resetCapable(8)
The hard-drive fault LED can be reset.
Chassis Information Group
111
book.book Page 112 Wednesday, March 6, 2013 12:37 AM
Table 5-8. Hard-Drive Fault LED Control Settings
Variable Name: DellHDFaultLEDControlSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The LEDs do not have any fault settings
capabilities.
unknown(1)
The hard-drive fault LEDs’ state is
unknown.
enabled(2)
The hard-drive fault LEDs’ state is disabled
(offline, a binary 0 value) or enabled (online,
a binary 1 value).
notReady(4)
The hard-drive fault LEDs’ state is not ready.
reset(8)
The hard-drive fault LEDs have been reset.
resetAndEnable(10)
The hard-drive fault LEDs have been reset
and enabled.
Table 5-9. Chassis Identification Control Capabilities
Variable Name: DellChassisIdentifyControlCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The LEDs do not have any chassis
identification capabilities.
unknownCapabilities(1)
The chassis identification control’s
capabilities are unknown.
enableCapable(2)
The chassis identification controls can be
disabled (offline, a binary 0 value) or
enabled (online, a binary 1 value).
notReadyCapable(4)
The chassis identification control’s
capabilities are not ready.
identifyCapable(8)
The chassis identification control’s LEDs
can be made to identify the chassis.
112
Chassis Information Group
book.book Page 113 Wednesday, March 6, 2013 12:37 AM
Table 5-9. Chassis Identification Control Capabilities (continued)
Variable Name: DellChassisIdentifyControlCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
NOTE: Chassis identification capabilities allow system administrators to set front
panel light-emitting diodes (LEDs) to blink when the chassis has malfunctioning
components. When enabled, the blinking lights help administrators locate the
problem chassis.
Table 5-10.
Chassis Identification Control Settings
Variable Name: DellChassisIdentifyControlSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
The chassis identification control’s state is
unknown.
enabled(2)
The chassis identification control’s state is
disabled (offline, a binary 0 value) or
enabled (online, a binary 1 value).
notReady(4)
The chassis identification control’s state
is not ready.
identifyChassis(8)
The chassis identification control’s
LEDs may be returned to (normal) 0,
or (identify chassis) 1.
identifyChassisAndEnable The chassis identification control’s
(10)
LEDs may be returned to normal
(a binary 0 value), or identify chassis
and enabled (a binary 1 value).
Chassis Information Group
113
book.book Page 114 Wednesday, March 6, 2013 12:37 AM
Table 5-11. Host Control Capabilities
Variable Name: DellHostControlCapabilities
NOTE: An operator can manually enable these actions using SNMP.
Data Type: Integer
Possible Data Values
Meaning of Data Value
manualRebootCapable(1)
The operator can reboot capable host.
manualPowerOFFCapable(2)
The operator can power off capable host.
manualPowerCycleCapable(4) The operator can power-cycle capable
host.
manualAllExceptOperating The operator can reboot and power off
SystemShutdownCapable(7) capable host.
manualOperatingSystemShut The operator can shut down the
downCapable(8)
operating-system–shutdown capable host.
manualFullyCapable(15)
The operator can reboot, power on and off
the power-cycle capable host, and shut
down the operating-system–shutdown
capable host.
manualRebootWithOSShutdow The operator can reboot with operating
nCapable(16)
system shutdown.
manualRebootWithoutOSShut The operator can reboot without
downCapable(32)
operating system shutdown.
manualPowerOffWithOSShutd The operator can power off with operating
ownCapable(64)
system shutdown.
manualPowerOffWithoutOSSh The operator can power off without
utdownCapable(128)
operating system shutdown.
manualPowerCycleWithOSShu The operator can power cycle with
tdownCapable(256)
operating system shutdown.
manualPowerCycleWithoutOS The operator can power cycle without
ShutdownCapable(512)
operating system shutdown.
114
Chassis Information Group
book.book Page 115 Wednesday, March 6, 2013 12:37 AM
Table 5-12.
Host Control Settings
Variable Name: DellHostControlSettings
NOTE: An operator can manually cause these actions using SNMP.
Data Type: Integer
Possible Data Values
Meaning of Data Value
manualReboot(1)
The operator can reboot the host.
manualPowerOFF(2)
The operator can power off the host.
manualPowerCycle(4)
Power cycle the host.
manualOperatingSystemShutdown(8) The operator can shut down the
operating system on the host.
manualOperatingSystemShutdownThe The operator can shut down the
nPowerCycle(12)
operating system on the host then
power cycle machine.
Table 5-13.
Watchdog Control Capabilities
Variable Name: DellWatchDogControlCapabilities
NOTE: When the system determines that the operating system is not responding, it
automatically performs the selected action without operator intervention.
Data Type: Integer
Possible Data Values
Meaning of Data Value
automaticRebootCapable(1)
Watchdog controls can be set to
reboot capable host.
automaticPowerCycleCapable(2)
Watchdog controls can be set to
power cycleable capable host.
automaticNotificationCapable(4) Watchdog controls can be set to
notify capable host.
automaticWatchDogTimerCapable(8) Watchdog controls can be set to
function automatically.
automaticPowerOffCapable(16)
Watchdog controls can be set to
automatically power off host.
Chassis Information Group
115
book.book Page 116 Wednesday, March 6, 2013 12:37 AM
Table 5-13. Watchdog Control Capabilities (continued)
Variable Name: DellWatchDogControlCapabilities
NOTE: When the system determines that the operating system is not responding, it
automatically performs the selected action without operator intervention.
Data Type: Integer
Possible Data Values
Meaning of Data Value
automaticAllExceptNotificationCap Watchdog controls can be set to
able(27)
automatically perform all functions
except notification capable.
automaticFullyCapable(31)
Watchdog controls can be set to
automatically perform all functions.
Table 5-14. Watchdog Control Settings
Variable Name: DellWatchControlSettings
NOTE: The watchdog timer is the mechanism used by a chassis to determine if the
operating system has stopped responding.
Data Type: Integer
Possible Data Values
Meaning of Data Value
automaticRebootEnabled(1)
Automatic reboot is enabled for this
host.
automaticPowerCycleEnabled(2)
Automatic power cycleable is enabled
for this host.
automaticNotificationEnabled(4) Automatic notification is enabled for
this host.
automaticPowerOffEnabled(8)
116
Chassis Information Group
Automatic power off is enabled for
this host.
book.book Page 117 Wednesday, March 6, 2013 12:37 AM
Table 5-15.
Watchdog Timer Capabilities
Variable Name: DellWatchDogTimerCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
type1Capable(1)
Watchdog timer can time in intervals from
20–480 seconds.
type2Capable(2)
Watchdog timer can time in 30-, 60-, 120-, and
480-second intervals.
type3Capable(4)
Watchdog timer can time in 60-second intervals.
Table 5-16.
Power Button Control Capabilities
Variable Name: DellPowerButtonControlCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The power button has no capabilities.
unknownCapabilities(1) The power button capabilities are unknown.
enableCapable(2)
Table 5-17.
The power button can be enabled (online) or
disabled (offline).
Power Button Control Settings
Variable Name: DellPowerButtonControlSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The power button has no settings capabilities.
unknown(1)
The power button settings are unknown.
enabled(2)
The power button state is enabled.
disabled(4)
The power button state is disabled.
Chassis Information Group
117
book.book Page 118 Wednesday, March 6, 2013 12:37 AM
Table 5-18. NMI Button Control Capabilities
Variable Name: DellNMIButtonControlCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The NMI button has no capabilities.
unknownCapabilities(1) The NMI button capabilities are unknown.
The NMI button can be enabled (online) or
disabled (offline).
enableCapable(2)
Table 5-19. System Properties
Variable Name: DellSystemProperties
NOTE: These values are bit masks, so combination values are possible.
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
No properties.
energySmart(1)
The system is an Energy Smart System.
Table 5-20. NMI Button Control Settings
Variable Name: DellNMIButtonControlSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The NMI button has no settings capabilities.
unknown(1)
The NMI button settings are unknown.
enabled(2)
The NMI button state is enabled.
disabled(4)
The NMI button state is disabled.
118
Chassis Information Group
book.book Page 119 Wednesday, March 6, 2013 12:37 AM
Table 5-21.
Baseboard Type
Variable Name: DellBaseBoardType
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
The baseboard type is unknown.
other(2)
The baseboard type is not one of the
following types.
serverBlade(3)
The baseboard type is a server blade.
connectivitySwitch(4)
The baseboard type is a connectivity switch.
systemManagementModule(5) The baseboard type is a system management
module.
processorModule(6)
The baseboard type is a processor module.
ioModule(7)
The baseboard type is an I/O module.
memoryModule(8)
The baseboard type is a memory module
daughterBoard(9)
The baseboard type is a daughter board.
motherboard(10)
The baseboard type is a mother board.
processorMemoryModule(11) The baseboard type is a processor or memory
module
processorIOModule(12)
The baseboard type is a processor or
I/O module
interconnectBoard(13)
The baseboard type is an interconnect board.
Table 5-22.
Chassis System Class
Variable Name: DellChassisSystemClass
Data Type: Integer
Possible Data Values
Meaning of Data Value
other(1)
The chassis system class is not one of the following:
unknown(2)
The chassis system class is unknown.
workstationClass(3) The chassis system class is a workstation.
serverClass(4)
The chassis system class is a server.
Chassis Information Group
119
book.book Page 120 Wednesday, March 6, 2013 12:37 AM
Table 5-22. Chassis System Class (continued)
Variable Name: DellChassisSystemClass
Data Type: Integer
Possible Data Values
Meaning of Data Value
desktopClass(5)
The chassis system class is a desktop.
portableClass(6)
The chassis system class is a portable.
netPCClass(7)
The chassis system class is a Net PC.
storageClass(8)
The chassis system class is storage.
Table 5-23. Firmware Type
Variable Name: DellFirmwareType
Data Type: Integer
Possible Data Values
Meaning of Data Value
other(1)
The firmware type is other than
following values.
unknown(2)
The firmware type is unknown.
systemBIOS(3)
The firmware type is System BIOS
embeddedSystemManagementContro The firmware type is Embedded
ller(4)
System Management Controller.
powerSupplyParallelingBoard(5) The firmware type is Power Supply
Paralleling Board.
systemBackPlane(6)
The firmware type is System
(Primary) Backplane.
powerVault2XXSKernel(7)
The firmware type is Dell
PowerVault 2XXS Kernel.
powerVault2XXSApplication(8)
The firmware type is PowerVault
2XXS Application.
frontPanel(9)
The firmware type is Front Panel
Controller.
baseboardManagementController
(10)
The firmware type is Baseboard
Management Controller.
120
Chassis Information Group
book.book Page 121 Wednesday, March 6, 2013 12:37 AM
Table 5-23.
Firmware Type (continued)
Variable Name: DellFirmwareType
Data Type: Integer
Possible Data Values
Meaning of Data Value
hotPlugPCI(11)
The firmware type is Hot Plug
Peripheral Component Interconnect
(PCI) Controller.
sensorData(12)
The firmware type is Sensor Data
Records.
peripheralBay(13)
The firmware type is Peripheral Bay
Backplane.
secondaryBackPlane(14)
The firmware type is Secondary
Backplane for ESM 2 systems.
secondaryBackPlaneESM3And4(15)
The firmware type is Secondary
Backplane for ESM 3 and 4 systems.
rac(16)
The firmware type is Remote
Access Controller.
iDRAC(17)
The firmware type is Integrated
Dell Remote Access Controller.
unifiedServerConfigurator(19)
The firmware type is Unified Server
Configurator.
lifecycleController(20)
The firmware type is Lifecycle
Controller.
Table 5-24.
Baseboard Feature Flags
Variable Name: DellBaseBoardFeatureFlags
Data Type: Integer
Possible Data Values
Meaning of Data Value
NOTE: These values are bit fields, so combination values are possible.
no features(0)
This baseboard has no feature flags.
boardIsHostingBoard(1)
This baseboard is a hosting board.
Chassis Information Group
121
book.book Page 122 Wednesday, March 6, 2013 12:37 AM
Table 5-24. Baseboard Feature Flags
Variable Name: DellBaseBoardFeatureFlags
Data Type: Integer
Possible Data Values
Meaning of Data Value
boardRequiresDaughterBoard This baseboard requires at least one
(2)
daughter board or auxiliary card.
boardIsRemovable(4)
This baseboard is removable.
boardIsReplaceable(8)
This baseboard is replaceable.
boardIsHotSwappable(16)
This baseboard is hot swappable.
122
Chassis Information Group
book.book Page 123 Wednesday, March 6, 2013 12:37 AM
Operating System Group
6
The Operating System Group provides status and identifying information
about a system’s operating system. Identifying information includes the
name, version, service pack, and patch level of the installed operating system.
Operating System Group Table
The following management information base (MIB) tables define the objects
in the Operating System Group:
•
"Operating System Table" on page 123
•
"Operating System Memory Table" on page 125
Operating System Table
The following object sets up the Operating System Table.
Name
operatingSystemTable
Object ID
1.3.6.1.4.1.674.10892.1.400.10
Description
Defines the Operating System Table.
Syntax
SEQUENCE OF OperatingSystemTableEntry
Access
Not accessible
Operating System Table Entry
Name
operatingSystemTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.400.10.1
Description
Defines the Operating System Table entry.
Syntax
OperatingSystemTableEntry
Access
Not accessible
Index
operatingSystemchassisIndex
Operating System Group
123
book.book Page 124 Wednesday, March 6, 2013 12:37 AM
Operating System Chassis Index
Name
operatingSystemchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.400.10.1.1
Description
Defines the index (one-based) of the associated chassis.
Syntax
DellObjectRange
Access
Read-only
Operating System State Capabilities
Name
operatingSystemStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.400.10.1.2
Description
Defines the capabilities of the operating system.
Syntax
DellStateCapabilities
Access
Read-only
Operating System State Settings
Name
operatingSystemStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.400.10.1.3
Description
Defines the state of the operating system.
Syntax
DellStateSettings
Access
Read-write
Operating System Status
Name
operatingSystemStatus
Object ID
1.3.6.1.4.1.674.10892.1.400.10.1.4
Description
Defines the status of the operating system.
Syntax
DellStatus
Access
Read-only
124
Operating System Group
book.book Page 125 Wednesday, March 6, 2013 12:37 AM
Operating System Is Primary
Name
operatingSystemIsPrimary
Object ID
1.3.6.1.4.1.674.10892.1.400.10.1.5
Description
Specifies whether this operating system is the primary operating
system.
Syntax
DellBoolean
Access
Read-only
Operating System Name
Name
operatingSystemOperatingSystemName
Object ID
1.3.6.1.4.1.674.10892.1.400.10.1.6
Description
Defines the name of the operating system running on the system.
Syntax
DisplayString (SIZE (0..255))
Access
Read-only
Operating System Version Name
Name
operatingSystemOperatingSystemVersionName
Object ID
1.3.6.1.4.1.674.10892.1.400.10.1.7
Description
Defines the version of the operating system running on the
system.
Syntax
DisplayString (SIZE (0..255))
Access
Read-only
Operating System Memory Table
Name
operatingSystemMemoryTable
Object ID
1.3.6.1.4.1.674.10892.1.400.20
Description
Defines the Operating System Memory Table.
Syntax
SEQUENCE OF OperatingSystemMemoryTableEntry
Access
Not accessible
Operating System Group
125
book.book Page 126 Wednesday, March 6, 2013 12:37 AM
Operating System Memory Table Entry
Name
operatingSystemTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.400.20.1
Description
Defines the Operating System Memory Table entry.
Syntax
OperatingSystemMemoryTableEntry
Access
Not accessible
Index
operatingSystemMemorychassisIndex
Operating System Memory Chassis Index
Name
operatingSystemMemorychassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.400.20.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Operating System Memory State Capabilities
Name
operatingSystemMemoryStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.400.20.1.2
Description
Defines the capabilities of the operating system memory.
Syntax
DellStateCapabilities
Access
Read-only
Operating System Memory State Settings
Name
operatingSystemMemoryStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.400.20.1.3
Description
Defines the state and allows the setting of the operating system
memory.
Syntax
DellStateSettings
Access
Read-write
126
Operating System Group
book.book Page 127 Wednesday, March 6, 2013 12:37 AM
Operating System Memory Status
Name
operatingSystemMemoryStatus
Object ID
1.3.6.1.4.1.674.10892.1.400.20.1.4
Description
Defines the status of the operating system memory.
Syntax
DellStatus
Access
Read-only
Operating System Memory Total Physical Size
Name
operatingSystemMemoryTotalPhysicalSize
Object ID
1.3.6.1.4.1.674.10892.1.400.20.1.5
Description
Defines the total physical memory size in kilobytes.
Syntax
DellUnsigned32BitRange
Access
Read-only
Operating System Memory Available Physical Size
Name
operatingSystemMemoryAvailablePhysicalSize
Object ID
1.3.6.1.4.1.674.10892.1.400.20.1.6
Description
Defines the available physical memory size in kilobytes.
Syntax
DellUnsigned32BitRange
Access
Read-only
Operating System Memory Total Page File Size
Name
operatingSystemMemoryTotalPageFileSize
Object ID
1.3.6.1.4.1.674.10892.1.400.20.1.7
Description
Defines the total page file memory size in kilobytes.
Syntax
DellUnsigned32BitRange
Access
Read-only
Operating System Group
127
book.book Page 128 Wednesday, March 6, 2013 12:37 AM
Operating System Memory Available Page File Size
Name
operatingSystemMemoryAvailablePageFileSize
Object ID
1.3.6.1.4.1.674.10892.1.400.20.1.8
Description
Defines the available page file memory size in kilobytes.
Syntax
DellUnsigned32BitRange
Access
Read-only
Operating System Memory Total Virtual Size
Name
operatingSystemMemoryTotalVirtualSize
Object ID
1.3.6.1.4.1.674.10892.1.400.20.1.9
Description
Defines the total virtual memory size in kilobytes.
Syntax
DellUnsigned32BitRange
Access
Read-only
Operating System Memory Available Virtual Size
Name
operatingSystemMemoryAvailableVirtualSize
Object ID
1.3.6.1.4.1.674.10892.1.400.20.1.10
Description
Defines the available virtual memory size in kilobytes.
Syntax
DellUnsigned32BitRange
Access
Read-only
128
Operating System Group
book.book Page 129 Wednesday, March 6, 2013 12:37 AM
Operating System Group
129
book.book Page 130 Wednesday, March 6, 2013 12:37 AM
130
Operating System Group
book.book Page 131 Wednesday, March 6, 2013 12:37 AM
System Resource Group
7
The Management Information Base (MIB) variables presented in this section
enable you to track various attributes of your system resources. This section
includes "System Resource Group Tables" on page 131 that track variables
such as the owner, ports, system memory, interrupts, and direct memory
access.
System Resource Group Tables
The following MIB tables define objects for the System Resource Group:
•
"System Resource Map Table" on page 131
•
"System Resource Owner Table" on page 133
•
"System Resource Input/Output (I/O) Port Table" on page 136
•
"System Resource Memory Table" on page 139
•
"System Resource Interrupt Table" on page 142
•
"System Resource Direct Memory Access (DMA) Table" on page 145
System Resource Map Table
Name
systemResourceMapTable
Object ID
1.3.6.1.4.1.674.10892.1.500.10
Description
Defines the System Resource Map Table.
Syntax
SEQUENCE OF SystemResourceMapTableEntry
Access
Not accessible
System Resource Group
131
book.book Page 132 Wednesday, March 6, 2013 12:37 AM
System Resource Map Table Entry
Name
systemResourceMapTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.500.10.1
Description
Defines the System Resource Map Table entry.
Syntax
SystemResourceMapTableEntry
Access
Not accessible
Index
systemResourceMapchassisIndex, systemResourceMapIndex
System Resource Map Chassis Index
Name
systemResourceMapChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.500.10.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource Map Index
Name
systemResourceMapIndex
Object ID
1.3.6.1.4.1.674.10892.1.500.10.1.2
Description
Defines the index of system resource maps in this chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource Map State Capabilities
Name
systemResourceMapStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.500.10.1.3
Description
Defines the capabilities of this system map.
Syntax
DellStateCapabilities
Access
Read-only
132
System Resource Group
book.book Page 133 Wednesday, March 6, 2013 12:37 AM
System Resource Map State Settings
Name
systemResourceMapStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.500.10.1.4
Description
Defines the state and allows the setting of this system map.
Syntax
DellStateSettings
Access
Read-write
System Resource Map Status
Name
systemResourceMapStatus
Object ID
1.3.6.1.4.1.674.10892.1.500.10.1.5
Description
Defines the status of this system map.
Syntax
DellStatus
Access
Read-only
System Resource Map Type
Name
systemResourceMapType
Object ID
1.3.6.1.4.1.674.10892.1.500.10.1.6
Description
Defines the type of this system map.
Syntax
DellSystemResourceMapType (See Table 7-1)
Access
Read-only
System Resource Owner Table
Name
systemResourceOwnerTable
Object ID
1.3.6.1.4.1.674.10892.1.500.20
Description
Defines the System Resource Owner Table.
Syntax
SEQUENCE OF SystemResourceOwnerTableEntry
Access
Not accessible
System Resource Group
133
book.book Page 134 Wednesday, March 6, 2013 12:37 AM
System Resource Owner Table Entry
Name
systemResourceOwnerTable
Object ID
1.3.6.1.4.1.674.10892.1.500.20.1
Description
Defines the System Resource Owner Table entry. Variables in
this group reference the System Resource Map index.
Syntax
SystemResourceOwnerTableEntry
Access
Not accessible
Index
systemResourceOwnerchassisIndex,
systemResourceOwnerIndex
System Resource Owner Chassis Index
Name
systemResourceOwnerchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.500.20.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource Owner Index
Name
systemResourceOwnerIndex
Object ID
1.3.6.1.4.1.674.10892.1.500.20.1.2
Description
Defines the index of system resource owners for this chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource Owner State Capabilities
Name
systemResourceOwnerStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.500.20.1.3
Description
Defines the capabilities of this system resource owner.
Syntax
DellStateCapabilities
Access
Read-only
134
System Resource Group
book.book Page 135 Wednesday, March 6, 2013 12:37 AM
System Resource Owner State Settings
Name
systemResourceOwnerStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.500.20.1.4
Description
Defines the state settings of this system resource owner.
Syntax
DellStateSettings
Access
Read-write
System Resource Owner Status
Name
systemResourceOwnerStatus
Object ID
1.3.6.1.4.1.674.10892.1.500.20.1.5
Description
Defines the status of this system resource owner.
Syntax
DellStatus
Access
Read-write
System Resource Owner Interface Type
Name
systemResourceOwnerInterfaceType
Object ID
1.3.6.1.4.1.674.10892.1.500.20.1.6
Description
Defines the interface type for this system resource owner.
Syntax
DellResourceOwnerInterfaceType (See Table 7-2)
Access
Read-only
System Resource Map Index Reference
Name
systemResourceMapIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.500.20.1.7
Description
Defines the index to the associated system resource map in this
chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource Group
135
book.book Page 136 Wednesday, March 6, 2013 12:37 AM
System Resource Owner Description Name
Name
systemResourceOwnerDescriptionName
Object ID
1.3.6.1.4.1.674.10892.1.500.20.1.8
Description
Defines the description name of the system resource owner.
Syntax
DellString
Access
Read-only
System Resource Owner Interface Instance
Name
systemResourceOwnerInterfaceInstance
Object ID
1.3.6.1.4.1.674.10892.1.500.20.1.9
Description
Defines the associated system resource owner interface instance
in this chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource Input/Output (I/O) Port Table
Name
systemResourceIOPortTable
Object ID
1.3.6.1.4.1.674.10892.1.500.30
Description
Defines the System Resource I/O Port Table.
Syntax
SEQUENCE OF SystemResourceIOPortTableEntry
Access
Not accessible
System Resource I/O Port Table Entry
Name
systemResourceIOPortTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.500.30.1
Description
Defines the System Resource I/O Port Table entry.
Syntax
SystemResourceIOPortTableEntry
Access
Not accessible
Index
systemResourceIOPortchassisIndex,
systemResourceIOPortIndex
136
System Resource Group
book.book Page 137 Wednesday, March 6, 2013 12:37 AM
System Resource I/O Port Chassis Index
Name
systemResourceIOPortchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.500.30.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource I/O Port Index
Name
systemResourceIOPortIndex
Object ID
1.3.6.1.4.1.674.10892.1.500.30.1.2
Description
Defines the index (one-based) of the system resource I/O ports
in this chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource I/O Port State Capabilities
Name
systemResourceIOPortStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.500.30.1.3
Description
Defines the capabilities of the system resource I/O port.
Syntax
DellStateCapabilities
Access
Read-only
System Resource I/O Port State Settings
Name
systemResourceIOPortStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.500.30.1.4
Description
Defines the state and allows the setting of the system resource
I/O port.
Syntax
DellStateSettings
Access
Read-write
System Resource Group
137
book.book Page 138 Wednesday, March 6, 2013 12:37 AM
System Resource I/O Port Status
Name
systemResourceIOPortStatus
Object ID
1.3.6.1.4.1.674.10892.1.500.30.1.5
Description
Defines the status of the system resource I/O port.
Syntax
DellStateSettings
Access
Read-only
System Resource I/O Port Owner Index Reference
Name
systemResourceIOPortOwnerIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.500.30.1.6
Description
Defines the index to the associated system resource owner in this
chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource I/O Port Share Disposition
Name
systemResourceIOPortShareDisposition
Object ID
1.3.6.1.4.1.674.10892.1.500.30.1.7
Description
Defines the share disposition of the system resource I/O port.
Syntax
DellResourceShareDisposition (See Table 7-3)
Access
Read-only
System Resource I/O Port Starting Address
Name
systemResourceIOPortStartingAddress
Object ID
1.3.6.1.4.1.674.10892.1.500.30.1.8
Description
Defines the 64 bits of the starting address of the system resource
I/O port.
Syntax
DellUnsigned64BitRange
Access
Read-only
138
System Resource Group
book.book Page 139 Wednesday, March 6, 2013 12:37 AM
System Resource I/O Port Ending Address
Name
systemResourceIOPortEndingAddress
Object ID
1.3.6.1.4.1.674.10892.1.500.30.1.9
Description
Defines the 64 bits of the ending address of the system resource
I/O port.
Syntax
DellUnsigned64BitRange
Access
Read-only
System Resource Memory Table
Name
systemResourceMemoryTable
Object ID
1.3.6.1.4.1.674.10892.1.500.40
Description
Defines the System Resource Memory Table.
Syntax
SEQUENCE OF SystemResourceMemoryTableEntry
Access
Not accessible
System Resource Memory Table Entry
Name
systemResourceMemoryTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.500.40.1
Description
Defines the System Resource Memory Table entry.
Syntax
SystemResourceMemoryTableEntry
Access
Not accessible
Index
systemResourceMemorychassisIndex,
systemResourceMemoryIndex
System Resource Memory Chassis Index
Name
systemResourceMemorychassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.500.40.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource Group
139
book.book Page 140 Wednesday, March 6, 2013 12:37 AM
System Resource Memory Index
Name
systemResourceMemoryIndex
Object ID
1.3.6.1.4.1.674.10892.1.500.40.1.2
Description
Defines the index of system resource memory in this chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource Memory State Capabilities
Name
systemResourceMemoryStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.500.40.1.3
Description
Defines the capabilities of this system resource memory.
Syntax
DellObjectRange
Access
Read-only
System Resource Memory State Settings
Name
systemResourceMemoryStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.500.40.1.4
Description
Defines the state of this system resource memory.
Syntax
DellObjectRange
Access
Read-write
System Resource Memory Status
Name
systemResourceMemoryStatus
Object ID
1.3.6.1.4.1.674.10892.1.500.40.1.5
Description
Defines the status of this system resource memory.
Syntax
DellStatus
Access
Read-only
140
System Resource Group
book.book Page 141 Wednesday, March 6, 2013 12:37 AM
System Resource Memory Owner Index Reference
Name
systemResourceMemoryOwnerIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.500.40.1.6
Description
Defines the index to the associated system resource owner in this
chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource Memory Share Disposition
Name
systemResourceMemoryShareDisposition
Object ID
1.3.6.1.4.1.674.10892.1.500.40.1.7
Description
Defines the share disposition of the system resource memory.
Syntax
DellResourceShareDisposition (See Table 7-3)
Access
Read-only
System Resource Memory Starting Address
Name
systemResourceMemoryStartingAddress
Object ID
1.3.6.1.4.1.674.10892.1.500.40.1.8
Description
Defines the 64 bits of the starting address of the system resource
memory.
Syntax
DellUnsigned64BitRange
Access
Read-only
System Resource Memory Ending Address
Name
systemResourceMemoryEndingAddress
Object ID
1.3.6.1.4.1.674.10892.1.500.40.1.9
Description
Defines the 64 bits of the ending address of the system resource
memory.
Syntax
DellUnsigned64BitRange
Access
Read-only
System Resource Group
141
book.book Page 142 Wednesday, March 6, 2013 12:37 AM
System Resource Memory Flags
Name
systemResourceMemoryFlags
Object ID
1.3.6.1.4.1.674.10892.1.500.40.1.10
Description
Defines the permission flags for the system resource memory.
Syntax
DellResourceMemoryFlags (See Table 7-4)
Access
Read-only
System Resource Interrupt Table
Name
systemResourceInterruptTable
Object ID
1.3.6.1.4.1.674.10892.1.500.50
Description
Defines the System Resource Interrupt Table.
Syntax
SEQUENCE OF SystemResourceInterruptTableEntry
Access
Not accessible
System Resource Interrupt Table Entry
Name
systemResourceInterruptTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.500.50.1
Description
Defines the System Resource Interrupt Table entry.
Syntax
SystemResourceInterruptTableEntry
Access
Not accessible
Index
systemResourceInterruptchassisIndex,
systemResourceInterruptIndex
System Resource Interrupt Chassis Index
Name
systemResourceInterruptchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.500.50.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Not accessible
142
System Resource Group
book.book Page 143 Wednesday, March 6, 2013 12:37 AM
System Resource Interrupt Index
Name
systemResourceInterruptIndex
Object ID
1.3.6.1.4.1.674.10892.1.500.50.1.2
Description
Defines the index (one-based) of this interrupt resource.
Syntax
DellObjectRange
Access
Read-only
System Resource Interrupt State Capabilities
Name
systemResourceInterruptStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.500.50.1.3
Description
Defines the capabilities of this system resource interrupt.
Syntax
DellStateCapabilities
Access
Read-only
System Resource Interrupt State Settings
Name
systemResourceInterruptStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.500.50.1.4
Description
Defines the state of this system resource interrupt.
Syntax
DellStateSettings
Access
Read-write
System Resource Interrupt Status
Name
systemResourceInterruptStatus
Object ID
1.3.6.1.4.1.674.10892.1.500.50.1.5
Description
Defines the status of this system resource interrupt.
Syntax
DellStatus
Access
Read-only
System Resource Group
143
book.book Page 144 Wednesday, March 6, 2013 12:37 AM
System Resource Interrupt Owner Index Reference
Name
systemResourceInterruptOwnerIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.500.50.1.6
Description
Defines the index for the associated system resource owner in
this chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource Interrupt Owner Share Disposition
Name
systemResourceInterruptShareDisposition
Object ID
1.3.6.1.4.1.674.10892.1.500.50.1.7
Description
Defines the share disposition of the system resource interrupt.
Syntax
DellResourceShareDisposition (See Table 7-3)
Access
Read-only
System Resource Interrupt Level
Name
systemResourceInterruptLevel
Object ID
1.3.6.1.4.1.674.10892.1.500.50.1.8
Description
Defines the interrupt request (IRQ) level of the system
resource interrupt.
Syntax
DellUnsigned32BitRange
Access
Read-only
System Resource Interrupt Type
Name
systemResourceInterruptType
Object ID
1.3.6.1.4.1.674.10892.1.500.50.1.9
Description
Defines the interrupt type of the system resource interrupt.
Syntax
DellResourceInterruptType (See Table 7-5)
Access
Read-only
144
System Resource Group
book.book Page 145 Wednesday, March 6, 2013 12:37 AM
System Resource Interrupt Trigger
Name
systemResourceInterruptTrigger
Object ID
1.3.6.1.4.1.674.10892.1.500.50.1.10
Description
Defines the interrupt trigger of the system resource interrupt.
Syntax
DellResourceInterruptTrigger (See Table 7-6)
Access
Read-only
System Resource Direct Memory Access (DMA) Table
Name
systemResourceDMATable
Object ID
1.3.6.1.4.1.674.10892.1.500.60
Description
Defines the System Resource DMA Table.
Syntax
SEQUENCE OF SystemResourceDMATableEntry
Access
Not accessible
System Resource DMA Table Entry
Name
systemResourceDMATable
Object ID
1.3.6.1.4.1.674.10892.1.500.60.1
Description
Defines the System Resource DMA Table entry.
Syntax
SystemResourceDMATableEntry
Access
Not accessible
Index
systemResourceDMAchassisIndex, systemResourceDMAIndex
System Resource DMA Chassis Index
Name
systemResourceDMAchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.500.60.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource Group
145
book.book Page 146 Wednesday, March 6, 2013 12:37 AM
System Resource DMA Index
Name
systemResourceDMAIndex
Object ID
1.3.6.1.4.1.674.10892.1.500.60.1.2
Description
Defines the index of system resource DMAs in this chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource DMA State Capabilities
Name
systemResourceDMAStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.500.60.1.3
Description
Defines the capabilities of this system resource DMA.
Syntax
DellStateCapabilities
Access
Read-only
System Resource DMA State Settings
Name
systemResourceDMAStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.500.60.1.4
Description
Defines the state and setting of this system resource DMA.
Syntax
DellStateSettings
Access
Read-write
System Resource DMA Status
Name
systemResourceDMAStatus
Object ID
1.3.6.1.4.1.674.10892.1.500.60.1.5
Description
Defines the status of this system resource DMA.
Syntax
DellStatus
Access
Read-only
146
System Resource Group
book.book Page 147 Wednesday, March 6, 2013 12:37 AM
System Resource DMA Owner Index Reference
Name
systemResourceDMAOwnerIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.500.60.1.6
Description
Defines the index to the associated system resource owner in this
chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource DMA Share Disposition
Name
systemResourceDMAShareDisposition
Object ID
1.3.6.1.4.1.674.10892.1.500.60.1.7
Description
Defines the share disposition of the system resource DMA.
Syntax
DellResourceShareDisposition (See Table 7-3)
Access
Read-only
System Resource DMA Maximum Transfer Size
Name
systemResourceDMAMaximumTransferSize
Object ID
1.3.6.1.4.1.674.10892.1.500.60.1.8
Description
Defines the maximum size of a memory transfer in bytes for the
system resource DMA.
Syntax
DellUnsigned32BitRange
Access
Read-only
System Resource DMA Transfer Width
Name
systemResourceDMATransferWidth
Object ID
1.3.6.1.4.1.674.10892.1.500.60.1.9
Description
Defines the transfer width of the system resource DMA.
Syntax
DellResourceDMATransferWidth (See Table 7-8)
Access
Read-only
System Resource Group
147
book.book Page 148 Wednesday, March 6, 2013 12:37 AM
System Resource DMA Bus Master
Name
systemResourceDMABusMaster
Object ID
1.3.6.1.4.1.674.10892.1.500.60.1.10
Description
Defines the bus mastering capabilities of the system resource DMA.
Syntax
DellResourceDMABusMaster (See Table 7-7)
Access
Read-only
System Resource Group Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 7-1. System Resource Map Type
Variable Name: DellSystemResourceMapType
Data Type: Integer
Possible Data Values
Meaning of Data Value
other(1)
The system resource map type is not one of the
following:
unknown(2)
The system resource map type is unknown
(not known or not monitored).
typeOne(3)
The system resource map is type 1 (one).
Table 7-2. Resource Owner Interface Type
Variable Name: DellResourceOwnerInterfaceType
Data Type: Integer
Possible Data Values
Meaning of Data Value
typeIsOther(1)
The interface type is not one of the following:
typeIsUnknown(2)
The interface type is unknown.
typeIsInternal(3)
The interface type is internal.
typeIsISA(4)
The interface type is an Industry Standard
Architecture (ISA) bus.
148
System Resource Group
book.book Page 149 Wednesday, March 6, 2013 12:37 AM
Table 7-2. Resource Owner Interface Type (continued)
Variable Name: DellResourceOwnerInterfaceType
Data Type: Integer
Possible Data Values
Meaning of Data Value
typeIsEISA(5)
The interface type is an Extended Industry Standard
Architecture (EISA) bus.
typeIsMCA(6)
The interface type is a microchannel architecture
(MCA) bus.
typeIsTurboChannel(7) The interface type is a turbo-channel bus.
Table 7-3. Resource Share Disposition
Variable Name: DellResourceShareDisposition
Data Type: Integer
Possible Data Values
Meaning of Data Value
shareIsOther(1)
The share disposition is not one of the following:
shareIsUnknown(2)
The share disposition is unknown (not known
or not monitored).
shareIsDeviceExclusive(3) The share disposition is device exclusive.
shareIsDriverExclusive(4) The share disposition is driver exclusive.
shareIsShared(5)
The share disposition is shared.
Table 7-4. Resource Memory Flags
Variable Name: DellResourceMemoryFlags
Data Type: Integer
Possible Data Values
Meaning of Data Value
memoryIsReadOnly(1)
The resource memory is read-only.
memoryIsWriteOnly(2)
The resource memory is write-only.
memoryIsPreFetchable(4)
The resource memory is prefetchable.
memoryIsCombinedWritable(8) The resource memory is read-write.
memoryIsF24(16)
The resource memory is F24.
System Resource Group
149
book.book Page 150 Wednesday, March 6, 2013 12:37 AM
Table 7-5. Resource Interrupt Type
Variable Name: DellResourceInterruptType
Data Type: Integer
Possible Data Values
Meaning of Data Value
interruptIsLevelSensitive(1) The interrupt type is level sensitive.
The interrupt type is latched.
interruptIsLatched(2)
Table 7-6. Resource Interrupt Trigger
Variable Name: DellResourceInterruptTrigger
Data Type: Integer
Possible Data Values
Meaning of Data Value
interruptIsActiveWhenLow(1)
The interrupt trigger is active on a
low signal.
interruptIsActiveWhenHigh(2) The interrupt trigger is active on a
high signal.
Table 7-7. Resource DMA Bus Master
Variable Name: DellResourceDMABusMaster
Data Type: Integer
Possible Data Values
Meaning of Data Value
dmaIsOther(1)
The DMA bus master capability is not one of
the following:
dmaIsUnknown(2)
The DMA bus master capability is unknown.
dmaIsNotABusmaster(3)
The DMA does not have bus master capability.
150
System Resource Group
book.book Page 151 Wednesday, March 6, 2013 12:37 AM
Table 7-8. Resource DMA Transfer Width
Variable Name: DellResourceDMATransferWidth
Data Type: Integer
Possible Data Values
Meaning of Data Value
dmaTransferWidthIsOther(1)
The DMA transfer width is not one of the
following:
dmaTransferWidthIsunknown(2) The DMA transfer width is unknown.
dmaTransferWidthIs8Bits(3)
The DMA transfer width is 8 bits.
dmaTransferWidthIs16Bits(4)
The DMA transfer width is 16 bits.
dmaTransferWidthIs32Bits(5)
The DMA transfer width is 32 bits.
dmaTransferWidthIs64Bits(6)
The DMA transfer width is 64 bits.
dmaTransferWidthIs128Bits(7) The DMA transfer width is 128 bits.
System Resource Group
151
book.book Page 152 Wednesday, March 6, 2013 12:37 AM
152
System Resource Group
book.book Page 153 Wednesday, March 6, 2013 12:37 AM
8
Power Group
The Power Group provides information about power units (a group of power
supplies in a system chassis), power supplies, and voltage and amperage probes.
NOTE: Power Management features are only available for PowerEdge systems
that have hot-swappable power supplies and not systems that have a fixed, nonredundant power supply installed.
Power Group Tables
The following management information base (MIB) tables define objects for
the Power Group:
•
"Power Unit Table" on page 153
•
"Power Supply Table" on page 156
•
"Voltage Probe Table" on page 160
•
"Amperage Probe Table" on page 165
•
"AC Power Switch Table" on page 171
•
"AC Power Cord Table" on page 173
•
"Battery Table" on page 176
•
"Power Usage Table" on page 178
•
"Power Profile Table" on page 184
Power Unit Table
Name
powerUnitTable
Object ID
1.3.6.1.4.1.674.10892.1.600.10
Description
Defines the Power Unit Table.
Syntax
PowerUnitTableEntry
Access
Not accessible
Power Group
153
book.book Page 154 Wednesday, March 6, 2013 12:37 AM
Power Unit Table Entry
Name
powerUnitTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.600.10.1
Description
Defines the Power Unit Table entry.
Syntax
DellObjectRange
Access
Read-only
Index
powerUnitchassisIndex, powerUnitIndex
Power Unit Chassis Index
Name
powerUnitchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.10.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Power Unit Index
Name
powerUnitIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.10.1.2
Description
Defines the index of the power unit in this chassis.
Syntax
DellObjectRange
Access
Read-only
Power Unit State Capabilities
Name
powerUnitStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.600.10.1.3
Description
Defines the capabilities of the power unit.
Syntax
DellStateCapabilities
Access
Read-only
154
Power Group
book.book Page 155 Wednesday, March 6, 2013 12:37 AM
Power Unit State Settings
Name
powerUnitStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.600.10.1.4
Description
Defines the state and settings of the power unit.
Syntax
DellStateSettings
Access
Read-write
Power Unit Redundancy Status
Name
powerUnitRedundancyStatus
Object ID
1.3.6.1.4.1.674.10892.1.600.10.1.5
Description
Defines the redundancy status of the power unit.
Syntax
DellStatusRedundancy
Access
Read-only
Power Supply Count for Redundancy
Name
powerSupplyCountForRedundancy
Object ID
1.3.6.1.4.1.674.10892.1.600.10.1.6
Description
Defines the total number of power supplies required for this
power unit to have redundancy.
Syntax
DellString
Access
Read-only
Power Unit Name
Name
powerUnitName
Object ID
1.3.6.1.4.1.674.10892.1.600.10.1.7
Description
Defines the name of the power unit in this chassis.
Syntax
DellString
Access
Read-only
Power Group
155
book.book Page 156 Wednesday, March 6, 2013 12:37 AM
Power Unit Status
Name
powerUnitStatus
Object ID
1.3.6.1.4.1.674.10892.1.600.10.1.8
Description
Defines the status of the power unit in this chassis.
Syntax
DellStatus
Access
Read-only
Power Supply Table
Name
powerSupplyTable
Object ID
1.3.6.1.4.1.674.10892.1.600.12
Description
Defines the Power Supply Table.
Syntax
PowerSupplyTableEntry
Access
Not accessible
Power Supply Table Entry
Name
powerSupplyTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1
Description
Defines the Power Supply Table entry.
Syntax
PowerSupplyTableEntry
Access
Not accessible
Index
powerSupplychassisIndex, powerSupplyIndex
Power Supply Chassis Index
Name
powerSupplychassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
156
Power Group
book.book Page 157 Wednesday, March 6, 2013 12:37 AM
Power Supply Index
Name
powerSupplyIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1.2
Description
Defines the index of power supply.
Syntax
DellObjectRange
Access
Read-only
Power Supply State Capabilities Unique
Name
powerSupplyStateCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1.3
Description
Defines the capabilities of the power supply.
Syntax
DellPowerSupplyStateCapabilitiesUnique (See Table 8-1)
Access
Read-only
Power Supply State Settings Unique
Name
powerSupplyStateSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1.4
Description
Defines the state and settings of the power supply.
Syntax
DellPowerSupplyStateSettingsUnique (See Table 8-2)
Access
Read-write
Power Supply Status
Name
powerSupplyStatus
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1.5
Description
Defines the status of the power supply.
Syntax
DellStatus
Access
Read-only
Power Group
157
book.book Page 158 Wednesday, March 6, 2013 12:37 AM
Power Supply Output Watts
Name
powerSupplyOutputWatts
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1.6
Description
Defines the maximum sustained output wattage of the power
supply in tenths of watts.
Syntax
DellSigned32BitRange
Access
Read-only
Power Supply Type
Name
powerSupplyType
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1.7
Description
Defines the type of power supply.
Syntax
DellPowerSupplyType (See Table 8-3)
Access
Read-only
Power Supply Location Name
Name
powerSupplyLocationName
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1.8
Description
Defines the location name of the power supply.
Syntax
DellString
Access
Read-only
Power Supply Input Voltage
Name
powerSupplyInputVoltage
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1.9
Description
Defines the input voltage to the power supply in volts.
Syntax
DellSigned32BitRange
Access
Read-only
158
Power Group
book.book Page 159 Wednesday, March 6, 2013 12:37 AM
Power Supply Power Unit Index Reference
Name
powerSupplypowerUnitIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1.10
Description
Defines the index to the associated system power unit in this chassis.
Syntax
DellObjectRange
Access
Read-only
Power Supply Sensor State
Name
powerSupplySensorState
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1.11
Description
Defines the state reported by the power supply sensor, and
supplements the state and settings of the power supply.
Syntax
DellPowerSupplySensorState (See Table 8-4)
Access
Read-only
Power Supply Configuration Error Type
Name
powerSupplyConfigurationErrorType
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1.12
Description
Defines the type of configuration error reported by the power
supply sensor.
Syntax
DellPowerSupplyConfigurationErrorType (See Table 8-5)
Access
Read-only
Power Supply Power Monitor Capable
Name
powerSupplyPowerMonitorCapable
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1.13
Description
Defines a boolean value that reports whether the power supply is
capable of monitoring power consumption.
Syntax
DellBoolean
Access
Read-only
Power Group
159
book.book Page 160 Wednesday, March 6, 2013 12:37 AM
Power Supply Rated Input Wattage
Name
powerSupplyRatedInputWattage
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1.14
Description
Defines the rated input wattage of the power supply (in tenths
of Watts.)
Syntax
DellSigned32BitRange
Access
Read-only
Voltage Probe Table
Name
voltageProbeTable
Object ID
1.3.6.1.4.1.674.10892.1.600.20
Description
Defines the Voltage Probe Table.
Syntax
VoltageProbeTableEntry
Access
Not accessible
Voltage Probe Table Entry
Name
voltageProbeTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1
Description
Defines the Voltage Probe Table entry.
Syntax
VoltageProbeTableEntry
Access
Not accessible
Index
voltageProbechassisIndex, voltageProbeIndex
Voltage Probe Chassis Index
Name
voltageProbechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
160
Power Group
book.book Page 161 Wednesday, March 6, 2013 12:37 AM
Voltage Probe Index
Name
voltageProbeIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.2
Description
Defines the index of voltage probes in this chassis.
Syntax
DellObjectRange
Access
Read-only
Voltage Probe State Capabilities
Name
voltageProbeStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.3
Description
Defines the capabilities of the voltage probe.
Syntax
DellStateCapabilities
Access
Read-only
Voltage Probe State Settings
Name
voltageProbeStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.4
Description
Defines the state and settings of the voltage probe.
Syntax
DellStateSettings
Access
Read-write
Voltage Probe Status
Name
voltageProbeStatus
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.5
Description
Defines the status of the voltage probe.
Syntax
DellStatusProbe
Access
Read-only
Power Group
161
book.book Page 162 Wednesday, March 6, 2013 12:37 AM
Voltage Probe Reading
Name
voltageProbeReading
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.6
Description
Defines the value of the voltage probe reading. The value is an integer
representing the voltage in millivolts that the probe is reading.
When the value for voltageProbeType is voltageProbeTypeIsDiscrete,
a value is not returned for this attribute.
Syntax
DellSigned32BitRange
Access
Read-only
Voltage Probe Type
Name
voltageProbeType
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.7
Description
Defines the type of the voltage probe.
Syntax
DellVoltageType
Access
Read-only
Voltage Probe Location Name
Name
voltageProbeLocationName
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.8
Description
Defines the location of the voltage probe in this chassis.
Syntax
DellString
Access
Read-only
Voltage Probe Upper Nonrecoverable Threshold
Name
voltageProbeUpperNonRecoverableThreshold
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.9
Description
Defines the value of the voltage probe’s upper nonrecoverable
threshold.
Syntax
DellSigned32BitRange
162
Power Group
book.book Page 163 Wednesday, March 6, 2013 12:37 AM
Name
voltageProbeUpperNonRecoverableThreshold
Access
Read-only
Voltage Probe Upper Critical Threshold
Name
voltageProbeUpperCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.10
Description
Defines the value of the voltage probe’s upper critical threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Voltage Probe Upper Noncritical Threshold
Name
voltageProbeUpperNonCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.11
Description
Defines the user-assigned value of the voltage probe’s upper
noncritical threshold.
Syntax
DellSigned32BitRange
Access
Read-write
Voltage Probe Lower Noncritical Threshold
Name
voltageProbeLowerNonCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.12
Description
Defines the user-assigned value of the voltage probe’s lower
noncritical threshold.
Syntax
DellSigned32BitRange
Access
Read-write
Power Group
163
book.book Page 164 Wednesday, March 6, 2013 12:37 AM
Voltage Probe Lower Critical Threshold
Name
voltageProbeLowerCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.13
Description
Defines the value of the voltage probe’s lower critical threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Voltage Probe Lower Nonrecoverable Threshold
Name
voltageProbeLowerNonRecoverableThreshold
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.14
Description
Defines the value of the voltage probe’s lower nonrecoverable
threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Voltage Probe Probe Capabilities
Name
voltageProbeProbeCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.15
Description
Defines the probe capabilities of the voltage probe.
Syntax
DellProbeCapabilities
Access
Read-only
164
Power Group
book.book Page 165 Wednesday, March 6, 2013 12:37 AM
Voltage Probe Discrete Reading
Name
voltageProbeDiscreteReading
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.16
Description
Defines the reading for a voltage probe of type
voltageProbeTypeIsDiscrete.
When the value for voltageProbeType is other than
voltageProbeTypeIsDiscrete, a value is not returned for this
attribute. When the value for voltageProbeType is
voltageProbeTypeIsDiscrete, the value returned for this attribute
is the discrete reading for the probe.
Syntax
DellVoltageDiscreteReading
Access
Read-only
Amperage Probe Table
Name
amperageProbeTable
Object ID
1.3.6.1.4.1.674.10892.1.600.30
Description
Defines the Amperage Probe Table.
Syntax
SEQUENCE OF AmperageProbeTableEntry
Access
Not accessible
Amperage Probe Table Entry
Name
amperageProbeTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1
Description
Defines the Amperage Probe Table entry.
Syntax
AmperageProbeTableEntry
Access
Not accessible
Index
amperageProbechassisIndex, amperageProbeIndex
Power Group
165
book.book Page 166 Wednesday, March 6, 2013 12:37 AM
Amperage Probe Chassis Index
Name
amperageProbechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Amperage Probe Index
Name
amperageProbeIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.2
Description
Defines the index of amperage probes in this chassis.
Syntax
DellObjectRange
Access
Read-only
Amperage Probe State Capabilities
Name
amperageProbeStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.3
Description
Defines the capabilities of the amperage probe.
Syntax
DellStateCapabilities
Access
Read-only
Amperage Probe State Settings
Name
amperageProbeStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.4
Description
Defines the state and settings of the amperage probe.
Syntax
DellStateSettings
Access
Read-write
166
Power Group
book.book Page 167 Wednesday, March 6, 2013 12:37 AM
Amperage Probe Status
Name
amperageProbeStatus
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.5
Description
Defines the status of the amperage probe.
Syntax
DellSigned32BitRange
Access
Read-only
Amperage Probe Reading
Name
amperageProbeReading
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.6
Description
Defines the reading for an amperage probe of type other than
amperageProbeTypeIsDiscrete.
When the value for amperageProbeType is
amperageProbeTypeIsPowerSupplyAmps or
amperageProbeTypeIsSystemAmps, the value returned for this
attribute is the power usage that the probe is reading in tenths
of Amperes.
When the value for amperageProbeType is
amperageProbeTypeIsPowerSupplyWatts or
amperageProbeTypeIsSystemWatts, the value returned for this
attribute is the power usage that the probe is reading in Watts.
When the value for amperageProbeType is other than
amperageProbeTypeIsDiscrete,
amperageProbeTypeIsPowerSupplyAmps,
amperageProbeTypeIsPowerSupplyWatts,
amperageProbeTypeIsSystemAmps, or
amperageProbeTypeIsSystemWatts, the value returned for this
attribute is the amperage that the probe is reading in Milliamps.
When the value for amperageProbeType is
amperageProbeTypeIsDiscrete, a value is not returned for this
attribute.
Syntax
DellSigned32BitRange
Access
Read-only
Power Group
167
book.book Page 168 Wednesday, March 6, 2013 12:37 AM
Amperage Probe Type
Name
amperageProbeType
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.7
Description
Defines the type of the amperage probe.
Syntax
DellAmperageProbeType
Access
Read-only
Amperage Probe Location Name
Name
amperageProbeLocationName
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.8
Description
Defines the location name of the amperage probe in this chassis.
Syntax
DellString
Access
Read-only
Amperage Probe Upper Nonrecoverable Threshold
Name
amperageProbeUpperNonRecoverableThreshold
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.9
Description
Defines the value of the amperage probe’s upper nonrecoverable
threshold. The value is an integer representing the amperage in
milliamperes that the probe is reading.
Syntax
DellSigned32BitRange
Access
Read-only
Amperage Probe Upper Critical Threshold
Name
amperageProbeUpperCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.10
Description
Defines the value of the amperage probe’s upper critical threshold.
Syntax
DellSigned32BitRange
Access
Read-only
168
Power Group
book.book Page 169 Wednesday, March 6, 2013 12:37 AM
Amperage Probe Upper Noncritical Threshold
Name
amperageProbeUpperNonCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.11
Description
Defines the user-assigned value of the amperage probe’s upper
critical threshold.
Syntax
DellSigned32BitRange
Access
Read-write
Amperage Probe Lower Noncritical Threshold
Name
amperageProbeLowerNonCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.12
Description
Defines the user-assigned value of the amperage probe’s lower
noncritical threshold.
Syntax
DellSigned32BitRange
Access
Read-write
Amperage Probe Lower Critical Threshold
Name
amperageProbeLowerCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.13
Description
Defines the value of the amperage probe’s lower
critical threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Power Group
169
book.book Page 170 Wednesday, March 6, 2013 12:37 AM
Amperage Probe Lower Nonrecoverable Threshold
Name
amperageProbeLowerNonRecoverableThreshold
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.14
Description
Defines the value of the amperage probe’s lower
nonrecoverable threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Amperage Probe Probe Capabilities
Name
amperageProbeProbeCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.15
Description
Defines the probe capabilities of the amperage probe.
Syntax
DellProbeCapabilities
Access
Read-only
Amperage Probe Discrete Reading
Name
amperageProbeDiscreteReading
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.16
Description
Defines the reading for a amperage probe of type
amperageProbeTypeIsDiscrete.
When the value for amperageProbeType is other than
amperageProbeTypeIsDiscrete, a value is not returned for this
attribute. When the value for amperageProbeType is
amperageProbeTypeIsDiscrete, the value returned for this
attribute is the discrete reading for the probe.
Syntax
DellAmperageDiscreteReading (See Table 8-9)
Access
Read-only
170
Power Group
book.book Page 171 Wednesday, March 6, 2013 12:37 AM
AC Power Switch Table
Name
aCPowerSwitchTable
Object ID
1.3.6.1.4.1.674.10892.1.600.40
Description
Defines the AC Power Switch Table.
Syntax
SEQUENCE OF ACPowerSwitchTableEntry
Access
Not accessible
AC Power Switch Table Entry
Name
aCPowerSwitchTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.600.40.1
Description
Defines the AC Power Switch Table entry.
Syntax
ACPowerSwitchTableEntry
Access
Not accessible
Index
aCPowerSwitchchassisIndex, aCPowerSwitchIndex
AC Power Switch Chassis Index
Name
aCPowerSwitchChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.40.1.1
Description
Defines the index (one-based) of the chassis containing this
AC power switch.
Syntax
DellObjectRange
Access
Read-only
AC Power Switch Index
Name
aCPowerSwitchIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.40.1.2
Description
Defines the index (one-based) of this AC power switch.
Syntax
DellObjectRange
Access
Read-only
Power Group
171
book.book Page 172 Wednesday, March 6, 2013 12:37 AM
AC Power Switch Capabilities
Name
aCPowerSwitchCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.600.40.1.3
Description
Defines the capabilities of this AC power switch.
Syntax
DellACPowerSwitchCapabilities
Access
Read-only
AC Power Switch Settings
Name
aCPowerSwitchSettings
Object ID
1.3.6.1.4.1.674.10892.1.600.40.1.4
Description
Defines the settings of this AC power switch.
Syntax
DellACPowerSwitchSettings
Access
Read-write
AC Power Switch Redundancy Status
Name
aCPowerSwitchRedundancyStatus
Object ID
1.3.6.1.4.1.674.10892.1.600.40.1.5
Description
Defines the redundancy status of this AC power switch.
Syntax
DellStatusRedundancy
Access
Read-only
AC Power Cord Count for Redundancy
Name
aCPowerCordCountForRedundancy
Object ID
1.3.6.1.4.1.674.10892.1.600.40.1.6
Description
Defines the total number of AC power cords required for this
AC power switch to have redundancy.
Syntax
DellObjectRange
Access
Read-only
172
Power Group
book.book Page 173 Wednesday, March 6, 2013 12:37 AM
AC Power Switch Name
Name
aCPowerSwitchName
Object ID
1.3.6.1.4.1.674.10892.1.600.40.1.7
Description
Defines the name of this AC power switch.
Syntax
DellString
Access
Read-only
AC Power Switch Redundancy Mode
Name
aCPowerSwitchRedundancyMode
Object ID
1.3.6.1.4.1.674.10892.1.600.40.1.8
Description
Defines the redundancy mode of this AC power switch.
Syntax
DellACPowerSwitchRedundancyMode
Access
Read-write
AC Power Switch Status
Name
aCPowerSwitchStatus
Object ID
1.3.6.1.4.1.674.10892.1.600.40.1.9
Description
Defines the status of this AC power switch.
Syntax
DellStatus
Access
Read-only
AC Power Cord Table
Name
aCPowerCordTable
Object ID
1.3.6.1.4.1.674.10892.1.600.42
Description
Defines the AC Power Cord Table.
Syntax
SEQUENCE OF ACPowerCordTableEntry
Access
Not accessible
Power Group
173
book.book Page 174 Wednesday, March 6, 2013 12:37 AM
AC Power Cord Table Entry
Name
aCPowerCordTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.600.42.1
Description
Defines the AC Power Cord Table entry.
Syntax
ACPowerCordTableEntry
Access
Not accessible
Index
aCPowerCordchassisIndex, aCPowerCordIndex
AC Power Cord Chassis Index
Name
aCPowerCordChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.42.1.1
Description
Defines the index (one-based) of the chassis containing this
AC power cord.
Syntax
DellObjectRange
Access
Read-only
AC Power Cord Index
Name
aCPowerCordIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.42.1.2
Description
Defines the index (one-based) of this AC power cord.
Syntax
DellObjectRange
Access
Read-only
AC Power Cord State Capabilities
Name
aCPowerCordStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.600.42.1.3
Description
Defines the capabilities of this AC power cord.
Syntax
DellACPowerCordStateCapabilities
Access
Read-only
174
Power Group
book.book Page 175 Wednesday, March 6, 2013 12:37 AM
AC Power Cord State Settings
Name
aCPowerCordStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.600.42.1.4
Description
Defines the settings of this AC power cord.
Syntax
DellACPowerCordStateSettings
Access
Read-write
AC Power Cord Status
Name
aCPowerCordStatus
Object ID
1.3.6.1.4.1.674.10892.1.600.42.1.5
Description
Defines the status of this AC power cord.
Syntax
DellStatus
Access
Read-only
AC Power Cord AC Power Switch Index Reference
Name
aCPowerCordaCPowerSwitchIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.600.42.1.6
Description
Defines the index (one-based) to the associated AC power switch
for this AC power cord.
Syntax
DellObjectRange
Access
Read-only
AC Power Cord Location Name
Name
aCPowerCordLocationName
Object ID
1.3.6.1.4.1.674.10892.1.600.42.1.7
Description
Defines the location name of this AC power cord.
Syntax
DellString
Access
Read-only
Power Group
175
book.book Page 176 Wednesday, March 6, 2013 12:37 AM
Battery Table
Name
batteryTable
Object ID
1.3.6.1.4.1.674.10892.1.600.50
Description
Defines the Battery Table.
Syntax
SEQUENCE OF BatteryTableEntry
Access
Not accessible
Battery Table Entry
Name
batteryTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.600.50.1
Description
Defines the Battery Table Entry.
Syntax
BatteryTableEntry
Access
Not accessible
Index
batteryChassisIndex, batteryIndex
Battery Chassis Index
Name
batteryChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.50.1.1
Description
Defines the index (one-based) of the chassis that contains the
battery.
Syntax
DellObjectRange
Access
Read-only
Battery Index
Name
batteryIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.50.1.2
Description
Defines the index (one-based) of the battery.
Syntax
DellObjectRange
Access
Read-only
176
Power Group
book.book Page 177 Wednesday, March 6, 2013 12:37 AM
Battery State Capabilities
Name
batteryStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.600.50.1.3
Description
Defines the state capabilities of the battery.
Syntax
DellStateCapabilities
Access
Read-only
Battery State Settings
Name
batteryStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.600.50.1.4
Description
Defines the state settings of the battery.
Syntax
DellStateSettings
Access
Read-write
Battery Status
Name
batteryStatus
Object ID
1.3.6.1.4.1.674.10892.1.600.50.1.5
Description
Defines the status of the battery.
Syntax
DellStatus
Access
Read-only
Battery Reading
Name
batteryReading
Object ID
1.3.6.1.4.1.674.10892.1.600.50.1.6
Description
Defines the reading of the battery.
Syntax
DellBatteryReading (see Table 8-15)
Access
Read-only
Power Group
177
book.book Page 178 Wednesday, March 6, 2013 12:37 AM
Battery Location Name
Name
batteryLocationName
Object ID
1.3.6.1.4.1.674.10892.1.600.50.1.7
Description
Defines the location of the battery.
Syntax
DellString
Access
Read-only
Power Usage Table
Name
powerUsageTable
Object ID
1.3.6.1.4.1.674.10892.1.600.60
Description
Defines the Power Usage Table.
Syntax
SEQUENCE OF PowerUsageTableEntry
Access
Not accessible
Power Usage Table Entry
Name
powerUsageTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.600.60.1
Description
Defines the Power Usage Table Entry.
Syntax
PowerUsageTableEntry
Access
Not accessible
Index
powerUsageChassisIndex, powerUsageIndex
Power Usage Chassis Index
Name
powerUsageChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.60.1.1
Description
Defines the index (one-based) of the associated chassis.
Syntax
DellObjectRange
Access
Read-only
178
Power Group
book.book Page 179 Wednesday, March 6, 2013 12:37 AM
Power Usage Index
Name
powerUsageIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.60.1.2
Description
Defines the index (one-based) of the power usage information.
Syntax
DellObjectRange
Access
Read-only
Power Usage State Capabilities
Name
powerUsageStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.600.60.1.3
Description
Defines the state capabilities of the power usage information.
Syntax
DellStateCapabilities
Access
Read-only
Power Usage State Settings
Name
powerUsageStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.600.60.1.4
Description
Defines the state settings of the power usage information.
Syntax
DellStateSettings
Access
Read-write
Power Usage Status
Name
powerUsageStatus
Object ID
1.3.6.1.4.1.674.10892.1.600.60.1.5
Description
Defines the status of the power usage information.
Syntax
DellStatus
Access
Read-only
Power Group
179
book.book Page 180 Wednesday, March 6, 2013 12:37 AM
Power Usage Entity Name
Name
powerUsageEntityName
Object ID
1.3.6.1.4.1.674.10892.1.600.60.1.6
Description
Defines the name of the entity associated with this power usage
information.
Syntax
DellString
Access
Read-only
Power Usage Cumulative Wattage
Name
powerUsageCumulativeWattage
Object ID
1.3.6.1.4.1.674.10892.1.600.60.1.7
Description
Defines the total wattage used (in Watt-hours) by this entity
since the date and time specified by the
powerUsageCumulativeWattageStartDateName attribute.
Syntax
DellUnsigned32BitRange
Access
Read-only
Power Usage Cumulative Wattage Start Date Name
Name
powerUsageCumulativeWattageStartDateName
Object ID
1.3.6.1.4.1.674.10892.1.600.60.1.8
Description
Defines the date and time at which the data collection started
for the value reported by the powerUsageCumulativeWattage
attribute.
Syntax
DellDateName
Access
Read-only
Power Usage Peak Watts
Name
powerUsagePeakWatts
Object ID
1.3.6.1.4.1.674.10892.1.600.60.1.9
180
Power Group
book.book Page 181 Wednesday, March 6, 2013 12:37 AM
Name
powerUsagePeakWatts
Description
Defines the peak wattage reading (in Watts) for this entity
since the date and time specified by the
powerUsagePeakWattsStartDateName attribute.
Syntax
DellUnsigned32BitRange
Access
Read-only
Power Usage Peak Watts Start Date Name
Name
powerUsagePeakWattsStartDateName
Object ID
1.3.6.1.4.1.674.10892.1.600.60.1.10
Description
Defines the date and time at which the data collection started
for the value reported by the powerUsagePeakWatts attribute.
Syntax
DellDateName
Access
Read-only
Power Usage Peak Watts Reading Date Name
Name
powerUsagePeakWattsReadingDateName
Object ID
1.3.6.1.4.1.674.10892.1.600.60.1.11
Description
Defines the date and time at which the value reported by the
powerUsagePeakWatts attribute was measured.
Syntax
DellDateName
Access
Read-only
Power Usage Peak Amps
Name
powerUsagePeakAmps
Object ID
1.3.6.1.4.1.674.10892.1.600.60.1.12
Description
Defines the peak amperage reading (in tenths of Amps) for this
entity since the date and time specified by the
powerUsagePeakAmpsStartDateName attribute.
Syntax
DellUnsigned32BitRange
Access
Read-only
Power Group
181
book.book Page 182 Wednesday, March 6, 2013 12:37 AM
Power Usage Peak Amps Start Date Name
Name
powerUsagePeakAmpsStartDateName
Object ID
1.3.6.1.4.1.674.10892.1.600.60.1.13
Description
Defines the date and time at which the data collection started
for the value reported by the powerUsagePeakAmps attribute.
Syntax
DellDateName
Access
Read-only
Power Usage Peak Amps Reading Date Name
Name
powerUsagePeakAmpsReadingDateName
Object ID
1.3.6.1.4.1.674.10892.1.600.60.1.14
Description
Defines the date and time at which the value reported by the
powerUsagePeakAmps attribute was measured.
Syntax
DellDateName
Access
Read-only
Power Usage Idle Power
Name
powerUsageIdlePower
Object ID
1.3.6.1.4.1.674.10892.1.600.60.1.15
Description
Defines the system idle power (in Watts). This is the minimum
power the system can consume based on the current hardware
configuration.
Syntax
DellUnsigned32BitRange
Access
Read-only
Power Usage Max Potential Power
Name
powerUsageMaxPotentialPower
Object ID
1.3.6.1.4.1.674.10892.1.600.60.1.16
182
Power Group
book.book Page 183 Wednesday, March 6, 2013 12:37 AM
Name
powerUsageMaxPotentialPower
Description
Defines the maximum potential power (in Watts) of the system.
This is the maximum power the system can consume based on
the current hardware configuration.
Syntax
DellUnsigned32BitRange
Access
Read-only
Power Usage Power Cap Capabilities
Name
powerUsagePowerCapCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.600.60.1.17
Description
Defines the system power cap capabilities.
Syntax
DellPowerCapCapabilities
Access
Read-only
Power Usage Power Cap Setting
Name
powerUsagePowerCapSetting
Object ID
1.3.6.1.4.1.674.10892.1.600.60.1.18
Description
Defines the system power cap setting.
Syntax
DellPowerCapSetting
Access
Read-only
Power Usage Power Cap Value
Name
powerUsagePowerCapValue
Object ID
1.3.6.1.4.1.674.10892.1.600.60.1.19
Description
Defines the system power cap value (in Watts).
Syntax
DellUnsigned32BitRange
Access
Read-only
Power Group
183
book.book Page 184 Wednesday, March 6, 2013 12:37 AM
Power Usage Instantaneous Headroom
Name
powerUsageInstantaneousHeadroom
Object ID
1.3.6.1.4.1.674.10892.1.600.60.1.20
Description
Defines the system instantaneous headroom (in Watts). This is
the theoretical maximum power drawn by the power supply
minus instantaneous power draw.
Syntax
DellUnsigned32BitRange
Access
Read-only
Power Usage Peak Headroom
Name
powerUsagePeakHeadroom
Object ID
1.3.6.1.4.1.674.10892.1.600.60.1.21
Description
Defines the system peak headroom (in Watts). This is the
theoretical maximum power drawn by the power supply minus
peak power draw.
Syntax
DellUnsigned32BitRange
Access
Read-only
Power Profile Table
Name
powerProfileTable
Object ID
1.3.6.1.4.1.674.10892.1.600.70
Description
Defines the Power Profile Table.
Syntax
SEQUENCE OF PowerProfileTableEntry
Access
Not accessible
Power Profile Table Entry
Name
powerProfileTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.600.70.1
Description
Defines the Power Profile Table Entry.
Syntax
PowerProfileTableEntry
184
Power Group
book.book Page 185 Wednesday, March 6, 2013 12:37 AM
Name
powerProfileTableEntry
Access
Not accessible
Index
powerProfileChassisIndex, powerProfileIndex
Power Profile Chassis Index
Name
powerProfileChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.70.1.1
Description
Defines the index (one-based) of the associated chassis.
Syntax
DellObjectRange
Access
Read-only
Power Profile Index
Name
powerProfileIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.70.1.2
Description
Defines the index (one-based) of the power profile information.
Syntax
DellObjectRange
Access
Read-only
Power Profile Supported Profiles
Name
powerProfileSupportedProfiles
Object ID
1.3.6.1.4.1.674.10892.1.600.70.1.3
Description
Defines the supported power profiles.
Syntax
DellPowerProfileType
Access
Read-only
Power Profile Setting
Name
powerProfileSetting
Object ID
1.3.6.1.4.1.674.10892.1.600.70.1.4
Description
Defines the power profile setting.
Power Group
185
book.book Page 186 Wednesday, March 6, 2013 12:37 AM
Name
powerProfileSetting
Syntax
DellPowerProfileType
Access
Read-only
Power Profile Custom CPU Management Capabilities
Name
powerProfileCustomCPUManagementCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.600.70.1.5
Description
Defines the custom CPU power and performance management
capabilities that are available for the Custom power profile.
Syntax
DellCPUPowerPerformanceManagementType
Access
Read-only
Power Profile Custom CPU Management Setting
Name
powerProfileCustomCPUManagementSetting
Object ID
1.3.6.1.4.1.674.10892.1.600.70.1.6
Description
Defines the custom CPU power and performance management
setting for the Custom power profile.
Syntax
DellCPUPowerPerformanceManagementType
Access
Read-only
Power Profile Custom Memory Management Capabilities
Name
powerProfileCustomMemoryManagementCapabiliti
es
Object ID
1.3.6.1.4.1.674.10892.1.600.70.1.7
Description
Defines the custom memory power and performance
management capabilities that are available for the Custom
power profile.
Syntax
DellMemoryPowerPerformanceManagementType
Access
Read-only
186
Power Group
book.book Page 187 Wednesday, March 6, 2013 12:37 AM
Power Profile Custom Memory Management Setting
Name
powerProfileCustomMemoryManagementSetting
Object ID
1.3.6.1.4.1.674.10892.1.600.70.1.8
Description
Defines the custom memory power and performance
management setting for the Custom power profile.
Syntax
DellMemoryPowerPerformanceManagementType
Access
Read-only
Power Profile Custom Fan Management Capabilities
Name
powerProfileCustomFanManagementCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.600.70.1.9
Description
Defines the custom fan power and performance management
capabilities that are available for the Custom power profile.
Syntax
DellFanPowerPerformanceManagementType
Access
Read-only
Power Profile Custom Fan Management Setting
Name
powerProfileCustomFanManagementSetting
Object ID
1.3.6.1.4.1.674.10892.1.600.70.1.10
Description
Defines the custom fan power and performance management
setting for the Custom power profile.
Syntax
DellFanPowerPerformanceManagementType
Access
Read-only
Power Group Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Power Group
187
book.book Page 188 Wednesday, March 6, 2013 12:37 AM
Table 8-1. Power Supply State Capabilities Unique
Variable Name: DellPowerSupplyStateCapabilitiesUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
The power supply’s capabilities are unknown.
onlineCapable(2)
The power supply can be disabled (offline, a binary
0 value) or enabled (online, a binary 1 value).
notReadyCapable(4)
The power supply’s capabilities are not ready.
Table 8-2. Power Supply State Settings Unique
Variable Name: DellPowerSupplyStateSettingsUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
The power supply’s capabilities are unknown.
onLine(2)
The power supply’s state is disabled (offline, a
binary 0 value) or enabled (online, a binary 1 value).
notReady(4)
The power supply’s state is not ready.
fanFailure(8)
The power supply fan has failed.
onlineAndFanFailure(10) The power supply is online and indicating that its
fan is not working.
powerSupplyIsON(16)
The power supply is indicating that it is on.
powerSupplyIsOk(32)
The power supply is indicating that it is OK.
acSwitchIsON(64)
The power supply is indicating that the AC power
switch is on.
onlineandAcSwitchIsON The power supply is online and indicating that the
(66)
AC power supply switch capability is activated.
acPowerIsON(128)
The power supply is indicating that the AC power
is on.
onlineAndAcPowerIsON
(130)
The power supply is online and indicating that the
AC power is on.
188
Power Group
book.book Page 189 Wednesday, March 6, 2013 12:37 AM
Table 8-2. Power Supply State Settings Unique (continued)
Variable Name: DellPowerSupplyStateSettingsUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
onlineAndPredictiveFail The power supply is online and indicating that it
ure(210)
has a problem.
acPowerAndSwitchAreOn The power supply is online and OK.
PowerSupplyIsOnIsOkAnd
Online(242)
Table 8-3. Power Supply Type Definitions
Variable Name: DellPowerSupplyType
Data Type: Integer
Possible Data Values
Meaning of Data Value
powerSupplyTypeIsOther(1)
The power supply type is not one of
the following:
powerSupplyTypeIsUnknown(2)
The power supply type is unknown
(not known or not monitored).
powerSupplyTypeIsLinear(3)
The power supply type is a linear
power supply.
powerSupplyTypeIsSwitching(4) The power supply type is a switching
power supply.
powerSupplyTypeIsBattery(5)
The power supply type is a battery.
powerSupplyTypeIsUPS(6)
The power supply type is an
uninterruptable power supply.
powerSupplyTypeIsConverter(7) The power supply type is a power
converter power supply.
powerSupplyTypeIsRegulator(8) The power supply type is a regulator
power supply.
powerSupplyTypeIsAC(9)
The power supply type is an AC power
supply.
Power Group
189
book.book Page 190 Wednesday, March 6, 2013 12:37 AM
Table 8-3. Power Supply Type Definitions (continued)
Variable Name: DellPowerSupplyType
Data Type: Integer
Possible Data Values
Meaning of Data Value
powerSupplyTypeIsDC(10)
The power supply type is a DC power
supply.
powerSupplyTypeIsVRM(11)
The power supply type is a voltage
regulator module (VRM) power
supply.
Table 8-4. Power Supply Sensor State
Variable Name: DellPowerSupplySensorState
Data Type: Integer
Possible Data Values
Meaning of Data Value
presenceDetected(1)
The power supply’s presence is detected.
psFailureDetected(2)
The power supply failure is detected.
predictiveFailure(4)
The power supply sensor detects predictive
failure
psACLost(8)
The power supply’s AC power is lost.
acLostOrOutOfRange(16)
The power supply’s AC power is lost or out
of range.
acOutOfRangeButPresent(32) The power supply’s AC power is present, but
it is out of range.
configurationError(64)
190
Power Group
The power supply sensor detects a
configuration error.
book.book Page 191 Wednesday, March 6, 2013 12:37 AM
Table 8-5. Power Supply Configuration Error Type
Variable Name: DellPowerSupplyConfigurationErrorType
Data Type: Integer
Possible Data Values
Meaning of Data Value
vendorMismatch(1)
The power supply configuration error type is
vendor mismatch.
revisionMismatch(2)
The power supply configuration error type is
revision mismatch.
processorMissing(3)
The power supply configuration error type is
processor missing.
Table 8-6. Voltage Probe Type
Variable Name: DellVoltageType
Data Type: Integer
Possible Data Values
Meaning of Data Value
voltageProbeTypeIsOther(1)
The voltage probe type is not one of the
following:
voltageProbeTypeIsUnknown(2) The voltage probe type is unknown
(not known or not monitored).
voltageProbeTypeIs1Point5Volt The voltage probe type is a 1.5-volt (V)
(3)
probe.
voltageProbeTypeIs3Point3Volt The voltage probe type is a 3.3-V probe.
(4)
voltageProbeTypeIs5Volt(5)
The voltage probe type is a 5-V probe.
voltageProbeTypeIsMinus5Volt The voltage probe type is a –5-V probe.
(6)
voltageProbeTypeIs12Volt(7)
The voltage probe type is a 12-V probe.
voltageProbeTypeIsMinus12Volt The voltage probe type is a –12-V probe.
(8)
voltageProbeTypeIsIO(9)
The voltage probe type is an I/O volt
probe.
Power Group
191
book.book Page 192 Wednesday, March 6, 2013 12:37 AM
Table 8-6. Voltage Probe Type (continued)
Variable Name: DellVoltageType
Data Type: Integer
Possible Data Values
Meaning of Data Value
voltageProbeTypeIsCore(10)
The voltage probe type is a core volt
probe.
voltageProbeTypeIsFLEA(11)
The voltage probe type is a FLEA
(standby) volt probe.
voltageProbeTypeIsBattery(12) The voltage probe type is a battery volt
probe.
voltageProbeTypeIsTerminator The voltage probe type is a SCSI
(13)
termination volt probe.
voltageProbeTypeIs2Point5Volt The voltage probe type is a 2.5-V probe.
(14)
The voltage probe type is a ground
termination logic (GTL) probe.
voltageProbeTypeIsGTL(15)
voltageProbeTypeIsDiscrete(16) The voltage probe type is a voltage probe
with discrete reading.
Table 8-7. Voltage Probe Discrete Reading
Variable Name: DellVoltageDiscreteReading
Data Type: Integer
Possible Data Values
Meaning of Data Value
voltageIsGood(1)
The voltage probe discrete reading is good.
voltageIsBad(2)
The voltage probe discrete reading is bad.
192
Power Group
book.book Page 193 Wednesday, March 6, 2013 12:37 AM
Table 8-8. Amperage Probe Definitions
Variable Name: DellAmperageType
Data Type: Integer
Possible Data Values
Meaning of Data Value
amperageProbeTypeIsOther(1)
The amperage probe type is
not one of the following:
amperageProbeTypeIsUnknown(2)
The amperage probe type is
unknown (not known or
not monitored).
amperageProbeTypeIs1Point5Volt(3)
The amperage probe type is a
1.5-ampere (A) probe.
amperageProbeTypeIs3Point3volt(4)
The amperage probe type is a
3.3-A probe.
amperageProbeTypeIs5Volt(5)
The amperage probe type is a
5-A probe.
amperageProbeTypeIsMinus5Volt(6)
The amperage probe type is a
–5-A probe.
amperageProbeTypeIs12Volt(7)
The amperage probe type is a
12-A probe.
amperageProbeTypeIsMinus12Volt(8)
The amperage probe type is a
–12-A probe.
amperageProbeTypeIsIO(9)
The amperage probe type is an
I/O amperage probe.
amperageProbeTypeIsCore(10)
The amperage probe type is a
core amperage probe.
amperageProbeTypeIsFLEA(11)
The amperage probe type is a
FLEA (standby) amperage
probe.
amperageProbeTypeIsBattery(12)
The amperage probe type is a
battery amperage probe.
amperageProbeTypeIsTerminator(13)
The amperage probe type is a
Small Computer System
Interface (SCSI) termination
amperage probe.
Power Group
193
book.book Page 194 Wednesday, March 6, 2013 12:37 AM
Table 8-8. Amperage Probe Definitions (continued)
Variable Name: DellAmperageType
Data Type: Integer
Possible Data Values
Meaning of Data Value
amperageProbeTypeIs2Point5Volt(14)
The amperage probe type is a
2.5-V amperage probe.
amperageProbeTypeIsGTL(15)
The amperage probe type is a
Gunning Transceiver Logic
(GTL) probe.
amperageProbeTypeIsDiscrete(16)
The amperage probe type is an
amperage probe with
discrete reading.
amperageProbeTypeIsPowerSupplyAmps(23) The amperage probe type is
power supply probe with
reading in Amperes.
amperageProbeTypeIsPowerSupplyWatts The amperage probe type is
(24)
power supply probe with
reading in Watts.
amperageProbeTypeIsSystemAmps(25)
The amperage probe type is
system probe with reading in
Amperes.
amperageProbeTypeIsSystemWatts(26)
The amperage probe type is
system probe with reading in
Watts.
Table 8-9. Amperage Probe Discrete Reading
Variable Name: DellAmperageDiscreteReading
Data Type: Integer
Possible Data Values
Meaning of Data Value
amperageIsGood(1)
The amperage probe discrete reading is good.
amperageIsBad(2)
The amperage probe discrete reading is bad.
194
Power Group
book.book Page 195 Wednesday, March 6, 2013 12:37 AM
Table 8-10.
AC Power Switch Capabilities
Variable Name: DellACPowerSwitchCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknownCapabilities(1)
The AC power switch’s capabilities
are unknown.
inputSourceCord1NoReturnCapable(2) Input source is AC power cord 1,
with no return.
inputSourceCord1ReturnCapable(4)
Input source is AC power cord 1,
with return.
inputSourceCord2NoReturnCapable(8) Input source is AC power cord 2,
with no return.
inputSourceCord2ReturnCapable(16)
Input source is AC power cord 2,
with return.
inputSourceSharedCapable(32)
Input source is shared.
Table 8-11.
AC Power Switch Settings
Variable Name: DellACPowerSwitchSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
The AC power switch’s settings are unknown.
inputSourceCord1NoReturn(2) Input source is AC power cord 1, with no return.
inputSourceCord1Return(4)
Input source is AC power cord 1, with return.
inputSourceCord2NoReturn(8) Input source is AC power cord 2, with no return.
inputSourceCord2Return(16)
Input source is AC power cord 2, with return.
inputSourceShared(32)
Input source is shared.
Power Group
195
book.book Page 196 Wednesday, March 6, 2013 12:37 AM
Table 8-12. AC Power Switch Redundancy Mode
Variable Name: DellACPowerSwitchRedundancyMode
Data Type: Integer
Possible Data Values
Meaning of Data Value
nonRedundant(1)
The AC power switch is not expecting redundancy.
redundant(2)
The AC power switch is expecting redundancy.
Table 8-13. AC Power Cord State Capabilities
Variable Name: DellACPowerCordStateCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
The AC power cord’s capabilities are unknown.
onlineCapable(2)
The AC power cord can be disabled (offline) or
enabled (online).
notReadyCapable(4)
The AC power cord’s capabilities are not ready.
Table 8-14. AC Power Cord State Settings
Variable Name: DellACPowerCordStateSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
The AC power cord’s state is unknown.
online(2)
The AC power cord’s state is disabled (offline) 0 or
enabled (online) 1.
notReady(4)
The AC power cord’s state is not ready.
acPowerCordHasPower The AC power cord has power.
(8)
acPowerCordIsActive The AC power cord is the active source of
Source(16)
AC power.
196
Power Group
book.book Page 197 Wednesday, March 6, 2013 12:37 AM
Table 8-15.
Battery Reading
Variable Name: DellBatteryReading
Data Type: Integer
NOTE: These values are bit masks, so combination values are possible.
Possible Data Values
Meaning of Data Value
predictiveFailure(1)
Battery sensor detects predictive failure.
failed(2)
Battery has failed.
presenceDetected(4)
Battery presence is detected.
Table 8-16.
Power Cap Capabilities
Variable Name: DellPowerCapCapabilities
Data Type: Integer
NOTE: These values are bit masks, so combination values are possible.
Possible Data Values
Meaning of Data Value
none(0)
No power cap capabilities are available.
enable(1)
Power cap can be enabled.
disable(2)
Power cap can be disabled.
Table 8-17.
Power Cap Setting
Variable Name: DellPowerCapSetting
Data Type: Integer
Possible Data Values
Meaning of Data Value
disabled(0)
Power cap is disabled.
enabled(1)
Power cap is enabled.
Power Group
197
book.book Page 198 Wednesday, March 6, 2013 12:37 AM
Table 8-18. Power Profile Type
Variable Name: DellPowerProfileType
Data Type: Integer
NOTE: These values are bit masks, so combination values are possible.
Possible Data Values
Meaning of Data Value
maxPerformance(1)
Power profile type is Maximum Performance.
osControl(2)
Power profile type is OS control.
activePowerController(4) Power profile type is Active Power Controller.
custom(8)
Power profile type is Custom.
Table 8-19. CPU Power Performance Management Type
Variable Name: DellCPUPowerPerformanceManagementType
Data Type: Integer
NOTE: These values are bit masks, so combination values are possible.
Possible Data Values
Meaning of Data Value
maxPerformance(1)
CPU power and performance management type is
Maximum Performance.
minPower(2)
CPU power and performance management type is
Minimum Power.
osDBPM(4)
CPU power and performance management type is
OS Demand Based Power Management.
systemDBPM(8)
CPU power and performance management type is
System Demand Based Power Management.
198
Power Group
book.book Page 199 Wednesday, March 6, 2013 12:37 AM
Table 8-20.
Memory Power Performance Management Type
Variable Name: DellMemoryPowerPerformanceManagementType
Data Type: Integer
NOTE: These values are bit masks, so combination values are possible.
Possible Data Values
Meaning of Data Value
maxPerformance(1)
Memory power and performance management
type is Maximum Performance.
mhz1333(2)
Memory power and performance is 1333 MHz.
mhz1067(4)
Memory power and performance is 1067 MHz.
mhz800(8)
Memory power and performance is 800 MHz.
minPower(16)
Memory power and performance management
type is Minimum Power.
Table 8-21.
Fan Power Performance Management Type
Variable Name: DellFanPowerPerformanceManagementType
Data Type: Integer
NOTE: These values are bit masks, so combination values are possible.
Possible Data Values
Meaning of Data Value
maxPerformance(1)
Fan power and performance management type is
Maximum Performance.
minPower(2)
Fan power and performance management type is
Minimum Power.
Power Group
199
book.book Page 200 Wednesday, March 6, 2013 12:37 AM
200
Power Group
book.book Page 201 Wednesday, March 6, 2013 12:37 AM
9
Thermal Group
The Thermal Group provides information about cooling units, cooling
devices, and temperature probes. Cooling units are sets of fans or other
cooling devices in a system chassis. Thermal Group variables include
threshold values and types of cooling devices and temperature probes.
Thermal Group Tables
The following management information base (MIB) tables define the objects
in the Thermal Group:
•
"Cooling Unit Table" on page 201
•
"Cooling Unit Status" on page 203
•
"Temperature Probe Table" on page 209
Cooling Unit Table
Name
coolingUnitTable
Object ID
1.3.6.1.4.1.674.10892.1.700.10
Description
Defines the Cooling Unit Table.
Syntax
TableEntry
Access
Not accessible
Cooling Unit Table Entry
Name
coolingUnitTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.700.10.1
Description
Defines the Cooling Unit Table entry.
Syntax
TableEntry
Access
Not accessible
Index
coolingUnitchassisIndex, coolingUnitIndex
Thermal Group
201
book.book Page 202 Wednesday, March 6, 2013 12:37 AM
Cooling Unit Chassis Index
Name
coolingUnitchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.700.10.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
TableEntry
Access
Read-only
Cooling Unit Index
Name
coolingUnitIndex
Object ID
1.3.6.1.4.1.674.10892.1.700.10.1.2
Description
Defines the index (one-based) of cooling units.
Syntax
DellObjectRange
Access
Read-only
Cooling Unit State Capabilities
Name
coolingUnitStateCapabilties
Object ID
1.3.6.1.4.1.674.10892.1.700.10.1.3
Description
Defines the capabilities of the cooling unit.
Syntax
DellStateCapabilities
Access
Read-only
Cooling Unit State Settings
Name
coolingUnitStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.700.10.1.4
Description
Defines the state and settings of the cooling unit.
Syntax
DellStateSettings
Access
Read-write
202
Thermal Group
book.book Page 203 Wednesday, March 6, 2013 12:37 AM
Cooling Unit Redundancy Status
Name
coolingUnitRedundancyStatus
Object ID
1.3.6.1.4.1.674.10892.1.700.10.1.5
Description
Defines the redundancy status of the cooling unit.
Syntax
DellStatusRedundancy
Access
Read-only
Cooling Device Count For Redundancy
Name
coolingDeviceCountForRedundancy
Object ID
1.3.6.1.4.1.674.10892.1.700.10.1.6
Description
Defines the total number of cooling devices required for this
cooling unit to have redundancy.
Syntax
DellObjectRange
Access
Read-only
Cooling Unit Name
Name
coolingUnitName
Object ID
1.3.6.1.4.1.674.10892.1.700.10.1.7
Description
Defines the cooling unit name in this chassis.
Syntax
DellString
Access
Read-only
Cooling Unit Status
Name
coolingUnitStatus
Object ID
1.3.6.1.4.1.674.10892.1.700.10.1.8
Description
Defines the status of the cooling unit in this chassis.
Syntax
DellStatus
Access
Read-only
Thermal Group
203
book.book Page 204 Wednesday, March 6, 2013 12:37 AM
Cooling Device Table
Name
coolingDeviceTable
Object ID
1.3.6.1.4.1.674.10892.1.700.12
Description
Defines the Cooling Device Table.
Syntax
CoolingDeviceTableEntry
Access
Not accessible
Cooling Device Table Entry
Name
coolingDeviceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1
Description
Defines the Cooling Device Table entry.
Syntax
CoolingDeviceTableEntry
Access
Not accessible
Index
cooling DevicechassisIndex, coolingDeviceIndex
Cooling Device Chassis Index
Name
coolingDevicechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Cooling Device Index
Name
coolingDeviceIndex
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.2
Description
Defines the index of cooling devices in this chassis.
Syntax
DellObjectRange
Access
Read-only
204
Thermal Group
book.book Page 205 Wednesday, March 6, 2013 12:37 AM
Cooling Device State Capabilities
Name
coolingDeviceStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.3
Description
Defines the capabilities of the cooling device.
Syntax
DellStateCapabilities
Access
Read-only
Cooling Device State Settings
Name
coolingDeviceStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.4
Description
Defines the state and settings of the cooling device.
Syntax
DellStateSettings
Access
Read-write
Cooling Device Status
Name
coolingDeviceStatus
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.5
Description
Defines the status of the cooling device.
Syntax
DellStatusProbe
Access
Read-only
Thermal Group
205
book.book Page 206 Wednesday, March 6, 2013 12:37 AM
Cooling Device Reading
Name
coolingDeviceReading
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.6
Description
Defines either the cooling device’s speed in revolutions
per minute (RPM), or the off/on value of the fan.
When the value for coolingDeviceSubType is other than
coolingDeviceSubTypeIsDiscrete, the value returned for this
attribute is the speed in RPM or the OFF/ON value of the cooling
device. When the value for coolingDeviceSubType is
coolingDeviceSubTypeIsDiscrete, a value is not returned for
this attribute.
Syntax
DellSigned32BitRange
Access
Read-only
Cooling Device Type
Name
coolingDeviceType
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.7
Description
Defines the cooling device type.
Syntax
DellCoolingDeviceType (See Table 9-1)
Access
Read-only
Cooling Device Location Name
Name
coolingDeviceLocationName
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.8
Description
Defines the location of the cooling device in this chassis.
Syntax
DellString
Access
Read-only
206
Thermal Group
book.book Page 207 Wednesday, March 6, 2013 12:37 AM
Cooling Device Upper Nonrecoverable Threshold
Name
coolingDeviceUppernonrecoverableThreshold
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.9
Description
Defines the value of the fan’s upper nonrecoverable threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Cooling Device Upper Critical Threshold
Name
coolingDeviceUpperCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.10
Description
Defines the value of the fan’s upper critical threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Cooling Device Upper Noncritical Threshold
Name
coolingDeviceUpperNonCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.11
Description
Defines the user-assigned value of the fan’s upper noncritical
threshold.
Syntax
DellSigned32BitRange
Access
Read-write
Cooling Device Lower Noncritical Threshold
Name
coolingDeviceLowerNonCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.12
Description
Defines the user-assigned value of the fan’s lower noncritical
threshold.
Syntax
DellSigned32BitRange
Access
Read-write
Thermal Group
207
book.book Page 208 Wednesday, March 6, 2013 12:37 AM
Cooling Device Lower Critical Threshold
Name
coolingDeviceLowerCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.13
Description
Defines the value of the fan’s lower critical threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Cooling Device Lower Nonrecoverable Threshold
Name
coolingDeviceLowerNonRecoverableThreshold
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.14
Description
Defines the value of the fan’s lower nonrecoverable threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Cooling Device Cooling Unit Index Reference
Name
coolingDevicecoolingUnitIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.15
Description
Defines the index for the associated system cooling unit in this
chassis.
Syntax
DellObjectRange
Access
Read-only
Cooling Device Subtype
Name
coolingDeviceSubType
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.16
Description
Defines the cooling device subtype.
Syntax
DellCoolingDeviceSubType (See Table 9-2)
Access
Read-only
208
Thermal Group
book.book Page 209 Wednesday, March 6, 2013 12:37 AM
Cooling Device Probe Capabilities
Name
coolingDeviceProbeCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.17
Description
Defines the probe capabilities of the cooling device.
Syntax
DellProbeCapabilities
Access
Read-only
Cooling Device Discrete Reading
Name
coolingDeviceDiscreteReading
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.18
Description
Defines the reading for a voltage probe of type
coolingDeviceSubTypeIsDiscrete.
When the value for coolingDeviceSubType is other than
coolingDeviceSubTypeIsDiscrete, a value is not returned for this
attribute. When the value for coolingDeviceSubType is
coolingDeviceSubTypeIsDiscrete, the value returned for this
attribute is the discrete reading for the cooling device.
Syntax
DellCoolingDeviceDiscreteReading (See Table 9-3)
Access
Read-only
Temperature Probe Table
Name
temperatureProbeTable
Object ID
1.3.6.1.4.1.674.10892.1.700.20
Description
Defines the Temperature Probe Table.
Syntax
TemperatureProbeTableEntry
Access
Not accessible
Thermal Group
209
book.book Page 210 Wednesday, March 6, 2013 12:37 AM
Temperature Probe Table Entry
Name
temperatureProbeTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1
Description
Defines the Temperature Probe Table entry.
Syntax
TemperatureProbeTableEntry
Access
Not accessible
Index
temperatureProbechassisIndex,
temperatureProbeIndex
Temperature Probe Chassis Index
Name
temperatureProbechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Temperature Probe Index
Name
temperatureProbeIndex
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.2
Description
Defines the index of temperature probes in this chassis.
Syntax
DellObjectRange
Access
Read-only
Temperature Probe State Capabilities
Name
temperatureProbeStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.3
Description
Defines the capabilities of the temperature probe.
Syntax
DellStateCapabilities
Access
Read-only
210
Thermal Group
book.book Page 211 Wednesday, March 6, 2013 12:37 AM
Temperature Probe State Settings
Name
temperatureProbeStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.4
Description
Defines the state and settings of the temperature probe.
Syntax
DellStateSettings
Access
Read-write
Temperature Probe Status
Name
temperatureProbeStatus
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.5
Description
Defines the status of the temperature probe in tenths of degrees
Celsius.
Syntax
DellStatusProbe
Access
Read-only
Temperature Probe Reading
Name
temperatureProbeReading
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.6
Description
Defines the value of the temperature probe.
When the value for temperatureProbeType is other than
temperatureProbeTypeIsDiscrete, the value returned for this
attribute is the temperature that the probe is reading in tenths
of degrees Centigrade. When the value for
temperatureProbeType is temperatureProbeTypeIsDiscrete,
a value is not returned for this attribute.
Syntax
DellSigned32BitRange
Access
Read-only
Thermal Group
211
book.book Page 212 Wednesday, March 6, 2013 12:37 AM
Temperature Probe Type
Name
temperatureProbeType
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.7
Description
Defines the temperature probe type.
Syntax
DellTemperatureProbeType (See Table 9-4)
Access
Read-only
Temperature Probe Location Name
Name
temperatureProbeLocationName
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.8
Description
Defines the location of the temperature probe in this chassis.
Syntax
DellString
Access
Read-only
Temperature Probe Upper Nonrecoverable Threshold
Name
temperatureProbeUpperNonRecoverableThreshold
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.9
Description
Defines the value of the temperature probe’s upper
nonrecoverable threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Temperature Probe Upper Critical Threshold
Name
temperatureProbeUpperCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.10
Description
Defines the value of the temperature probe’s upper critical
threshold.
Syntax
DellSigned32BitRange
Access
Read-only
212
Thermal Group
book.book Page 213 Wednesday, March 6, 2013 12:37 AM
Temperature Probe Upper Noncritical Threshold
Name
temperatureProbeUpperNonCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.11
Description
Defines the user-assigned value of the temperature probe’s
upper noncritical threshold.
Syntax
DellSigned32BitRange
Access
Read-write
Temperature Probe Lower Noncritical Threshold
Name
temperatureProbeLowerNonCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.12
Description
Defines the user-assigned value of the temperature probe’s
lower noncritical threshold.
Syntax
DellSigned32BitRange
Access
Read-write
Temperature Probe Lower Critical Threshold
Name
temperatureProbeLowerCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.13
Description
Defines the value of the temperature probe’s lower critical threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Temperature Probe Lower Nonrecoverable Threshold
Name
temperatureProbeLowerNonRecoverableThreshold
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.14
Description
Defines the value of the temperature probe’s lower
nonrecoverable threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Thermal Group
213
book.book Page 214 Wednesday, March 6, 2013 12:37 AM
Temperature Probe Probe Capabilities
Name
temperatureProbeProbeCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.15
Description
Defines the probe capabilities of the temperature probe.
Syntax
DellProbeCapabilities
Access
Read-only
Temperature Probe Discrete Reading
Name
temperatureProbeDiscreteReading
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.16
Description
Defines the reading for a temperature probe of type
temperatureProbeTypeIsDiscrete.
When the value for temperatureProbeType is other than
temperatureProbeTypeIsDiscrete, a value is not returned for this
attribute. When the value for temperatureProbeType is
temperatureProbeTypeIsDiscrete, the value returned for this
attribute is the discrete reading for the probe.
Syntax
DellTemperatureDiscreteReading (See Table 9-5)
Access
Read-only
214
Thermal Group
book.book Page 215 Wednesday, March 6, 2013 12:37 AM
Thermal Group Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 9-1. Cooling Device Type
Variable Name: DellCoolingDeviceType
Data Type: Integer
Possible Data Values
Meaning of Data Value
coolingDeviceTypeIsOther(1)
The cooling device type is not
one of the following:
coolingDeviceTypeIsUnknown(2)
The cooling device type is
unknown (not known or not
monitored).
coolingDeviceTypeIsAFan(3)
The cooling device type is
a fan.
coolingDeviceTypeIsABlower(4)
The cooling device type is a
centrifugal blower.
coolingDeviceTypeIsAChipFan(5)
The cooling device type is a
fan on an integrated circuit.
coolingDeviceTypeIsACabinetFan(6)
The cooling device type is a
cabinet fan.
coolingDeviceTypeIsAPowerSupplyFan(7) The cooling device type is a
power supply fan.
coolingDeviceTypeIsAHeatPipe(8)
The cooling device type is a
heat pipe.
coolingDeviceTypeIsRefrigeration(9)
The cooling device type is an
integrated refrigeration unit.
coolingDeviceTypeIsActiveCooling(10)
The cooling device type is an
active cooling device.
coolingDeviceTypeIsPassiveCooling(11) The cooling device type is a
passive cooling device.
Thermal Group
215
book.book Page 216 Wednesday, March 6, 2013 12:37 AM
Table 9-2. Cooling Device Subtype
Variable Name: DellCoolingDeviceSubType
Data Type: Integer
Possible Data Values
Meaning of Data Value
coolingDeviceSubTypeIsOther(1)
The cooling device subtype is
not one of the following:
coolingDeviceSubTypeIsUnknown(2)
The cooling device subtype is
unknown (not known or
not monitored).
coolingDeviceSubTypeIsAFanThatReads The cooling device subtype is a
InRPM(3)
fan that reads in RPMs.
coolingDeviceSubTypeIsAFanReadsONor The cooling device subtype is a
OFF(4)
fan that reads 0 (off) or 1 (on).
coolingDeviceSubTypeIsAPowerSupply The cooling device subtype is a
FanThatReadsinRPM(5)
power supply fan that reads in
RPMs.
coolingDeviceSubTypeIsAPowerSupply The cooling device subtype is a
FanThatReads- ONorOFF(6)
power supply fan that
reads 0 (off) or 1 (on).
coolingDeviceSubTypeIsDiscrete(16)
The cooling device subtype is a
cooling device with
discrete reading.
Table 9-3. Cooling Device Discrete Reading
Variable Name: DellCoolingDeviceDiscreteReading
Data Type: Integer
Possible Data Values
Meaning of Data Value
coolingDeviceIsGood(1)
The cooling device discrete reading is good.
coolingDeviceIsBad(2)
The cooling device discrete reading is bad.
216
Thermal Group
book.book Page 217 Wednesday, March 6, 2013 12:37 AM
Table 9-4. Temperature Probe Type
Variable Name: DellTemperatureProbeType
Data Type: Integer
Possible Data Values
Meaning of Data Value
temperatureProbeTypeIsOther(1)
The temperature probe subtype
is not one of the following:
temperatureProbeTypeIsUnknown(2)
The temperature probe subtype
is unknown (not known or not
monitored).
temperatureProbeTypeIsAmbientESM(3) The temperature probe is for
ambient Embedded Systems
Management (ESM).
temperatureProbeTypeIsDiscrete(16)
The temperature probe subtype
is a temperature probe with
discrete reading.
Table 9-5. Temperature Probe Discrete Reading
Variable Name: DellTemperatureDiscreteReading
Data Type: Integer
Possible Data Values
Meaning of Data Value
temperatureIsGood(1)
The temperature probe discrete reading is good.
temperatureIsBad(2)
The temperature probe discrete reading is bad.
Thermal Group
217
book.book Page 218 Wednesday, March 6, 2013 12:37 AM
218
Thermal Group
book.book Page 219 Wednesday, March 6, 2013 12:37 AM
10
User Security Group
The User Security Table defines the objects that allow administrators to
create and modify user accounts and to control which users can perform Set
operations on managed systems.
User Security Group Table
The User Security Group defines objects in the User Security MIB table.
User Security Table
The following object sets up the User Security Table:
Name
userSecurityTable
Object ID
1.3.6.1.4.1.674.10892.1.800
Description
Contains the database of users that are authorized to perform
Set operations on a managed system.
Syntax
UserSecurityTableEntry
Access
Not accessible
User Security Table Entry
Name
userSecurityTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.800.1
Description
Defines a row in the User Security Table.
Syntax
UserSecurityTableEntry
Access
Not accessible
Index
userSecuritychassisIndex, userSecurityIndex
User Security Group
219
book.book Page 220 Wednesday, March 6, 2013 12:37 AM
User Security Chassis Index
Name
userSecuritychassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.800.1.1
Description
Defines the user security index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
User Security Index
Name
userSecurityIndex
Object ID
1.3.6.1.4.1.674.10892.1.800.1.2
Description
Defines the user security index.
Syntax
DellObjectRange
Access
Read-only
User Security User Name
Name
userSecurityUserName
Object ID
1.3.6.1.4.1.674.10892.1.800.1.3
Description
Defines the user security user name.
Syntax
DellSecurityString
Access
Read-only
User Security Control Name
Name
userSecurityControlName
Object ID
1.3.6.1.4.1.674.10892.1.800.1.4
Description
Defines a control name used for creating, deleting, and editing
users.
Syntax
DellSecurityString
Access
Read-write
220
User Security Group
book.book Page 221 Wednesday, March 6, 2013 12:37 AM
User Security Request Name
Name
userSecurityRequestName
Object ID
1.3.6.1.4.1.674.10892.1.800.1.5
Description
Defines a request name used for creating, deleting, and editing
users.
Syntax
DellSecurityString
Access
Read-write
User Security Group
221
book.book Page 222 Wednesday, March 6, 2013 12:37 AM
222
User Security Group
book.book Page 223 Wednesday, March 6, 2013 12:37 AM
Remote Flash BIOS Group
11
The Remote Flash Basic Input/Output System (BIOS) Table defines the
variables used to remotely update the BIOS in a system. The variables also
define the capabilities of BIOS updates on the system.
Remote Flash BIOS Group Table
The Remote Flash BIOS Group defines objects in the Remote Flash BIOS
MIB table.
Remote Flash BIOS Table
The following object sets up the Remote Flash BIOS Table:
Name
remoteFlashBIOSTable
Object ID
1.3.6.1.4.1.674.10892.1.900.10
Description
Defines the Remote Flash BIOS Table.
Syntax
RemoteFlashBIOSTableEntry
Access
Not accessible
Remote Flash BIOS Table Entry
Name
remoteFlashBIOSTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.900.10.1
Description
Defines the Remote Flash BIOS Table entry.
Syntax
RemoteFlashBIOSTableEntry
Access
Not accessible
Index
remoteFlashBIOSchassisIndex, remoteFlashBIOSIndex
Remote Flash BIOS Group
223
book.book Page 224 Wednesday, March 6, 2013 12:37 AM
Remote Flash BIOS Chassis Index
Name
remoteFlashBIOSchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.900.10.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Remote Flash BIOS Index
Name
remoteFlashBIOSIndex
Object ID
1.3.6.1.4.1.674.10892.1.900.10.1.2
Description
Defines the index to the remote BIOS update hardware on this
system.
Syntax
DellObjectRange
Access
Read-only
Remote Flash BIOS State Capabilities Unique
Name
remoteFlashBIOSStateCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.900.10.1.3
Description
Defines the capabilities of the remote BIOS update hardware on
this system.
Syntax
DellRemoteFlashBIOSStateCapabilitiesUnique (See Table 11-1)
Access
Read-only
Remote Flash BIOS State Settings Unique
Name
remoteFlashBIOSStateSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.900.10.1.4
Description
Defines the state and settings of the remote BIOS update
hardware on this system.
Syntax
DellRemoteFlashBIOSStateSettingsUnique (See Table 11-2)
Access
Read-write
224
Remote Flash BIOS Group
book.book Page 225 Wednesday, March 6, 2013 12:37 AM
Remote Flash BIOS Status
Name
remoteFlashBIOSStatus
Object ID
1.3.6.1.4.1.674.10892.1.900.10.1.5
Description
Defines the status of the remote BIOS update hardware on
this system.
Syntax
DellRemoteFlashBIOSStateStatus
Access
Read-only
Remote Flash BIOS Last BIOS Date Name
Name
remoteFlashBIOSLastBIOSDateName
Object ID
1.3.6.1.4.1.674.10892.1.900.10.1.6
Description
Defines the date of the last BIOS update.
Syntax
DellDateName
Access
Read-only
Remote Flash BIOS Completion Code
Name
remoteFlashBIOSCompletionCode
Object ID
1.3.6.1.4.1.674.10892.1.900.10.1.7
Description
Defines the completion code of the last BIOS update.
Syntax
DellRemoteFlashBIOSCompletionCode (See Table 11-3 on
page 227)
Access
Read-only
Remote Flash BIOS Minimum Contiguous Memory
Name
remoteFlashBIOSMinimumContiguousMemory
Object ID
1.3.6.1.4.1.674.10892.1.900.10.1.8
Description
Defines the minimum size of contiguous memory required for
remote BIOS update in kilobytes.
Syntax
DellUnsigned32BitRange
Access
Read-only
Remote Flash BIOS Group
225
book.book Page 226 Wednesday, March 6, 2013 12:37 AM
Remote Flash BIOS Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 11-1. Remote Flash BIOS State Capabilities Unique
Variable Name: DellRemoteFlashBIOSStateCapabilitiesUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
The remote flash BIOS’s capabilities are
unknown.
enableCapable(2)
The remote flash BIOS can be disabled
(offline, a binary 0 value) or enabled (online,
a binary 1 value).
notReadyCapable(4)
The remote flash BIOS can be set to
indicate not ready.
cancelCapable(8)
Flash of BIOS can be canceled.
enableAndCancelCapable(10) Flash of BIOS can be enabled or canceled.
Table 11-2. Remote Flash BIOS State Settings
Variable Name: DellRemoteFlashBIOSStateSettingsUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
The remote flash BIOS’s capabilities are unknown.
enabled(2)
The remote flash BIOS update is disabled (offline, a
binary 0 value) or enabled (online, a binary 1 value).
notReady(4)
The remote flash BIOS’s state is not ready.
canceled(8)
The remote flash BIOS has been canceled.
pending(16)
The remote flash BIOS update is pending.
other(32)
The remote flash BIOS state/setting is not one of
the previous values.
226
Remote Flash BIOS Group
book.book Page 227 Wednesday, March 6, 2013 12:37 AM
Table 11-3.
Remote Flash BIOS Completion Code
Variable Name: DellRemoteFlashBIOSCompletionCode
Data Type: Integer
Possible Data Values
Meaning of Data Value
completionCodeIsOther(1)
The completion code status is
not one of the following:
completionCodeIsUnknown(2)
The completion code is unknown
(not known or not monitored).
completionCodeIsOK(3)
This completion code completed
successfully.
completionCodeIsBadImage(4)
This completion code is a bad
flash BIOS image.
completionCodeIsNoFileAccess(5)
Flash BIOS could not be
accessed.
completionCodeIsNotReady(6)
Flash BIOS memory not ready.
completionCodeIsDisabled(7)
Flash BIOS is currently disabled.
completionCodeIsNoBattery(8)
A battery must be installed.
completionCodeIsNoChargedBattery(9) A fully charged battery must be
installed.
completionCodeIsNoExternalPower(10) An external power adapter must
be connected.
12 volts (V) could not be set.
completionCodeIsNo12VoltSet(11)
completionCodeIsNo12VoltRemoval(12) 12 V could not be removed.
completionCodeIsFlashMemoryFailed
(13)
A flash memory failure occurred.
completionCodeIsGeneralFailure(14) A general failure occurred.
completionCodeIsDataMiscompare(15) A data miscompare error
occurred.
completionCodeIsNoImageFound(16)
The flash BIOS image could not
be found in memory.
completionCodeIsNoUpdatePerformed
(17)
No update operation has been
performed.
Remote Flash BIOS Group
227
book.book Page 228 Wednesday, March 6, 2013 12:37 AM
228
Remote Flash BIOS Group
book.book Page 229 Wednesday, March 6, 2013 12:37 AM
12
Port Group
The Port Group provides information about the different types of ports that
may be present in your system. This management information base (MIB)
group also provides information about the capabilities, states, and settings
that are possible for each port.
Port Group Tables
The following MIB tables define objects in the Port Group:
•
"Pointing Port Table" on page 229
•
"Keyboard Port Table" on page 232
•
"Processor Port Table" on page 235
•
"Memory Device Port Table" on page 238
•
"Monitor Port Table" on page 241
•
"Small Computer System Interface (SCSI) Port Table" on page 244
•
"Parallel Port Table" on page 246
•
"Serial Port Table" on page 250
•
"Universal Serial Bus (USB) Port Table" on page 254
Pointing Port Table
Name
pointingPortTable
Object ID
1.3.6.1.4.1.674.10892.1.1000.10
Description
Defines the Pointing Port Table.
Syntax
IntegerPointingPortTableEntry
Access
Not accessible
Port Group
229
book.book Page 230 Wednesday, March 6, 2013 12:37 AM
Pointing Port Table Entry
Name
pointingPortTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1000.10.1
Description
Defines the Pointing Port Table entry.
Syntax
PointingPortTableEntry
Access
Not accessible
Index
pointingPortchassisIndex, pointingPortIndex
Pointing Port Chassis Index
Name
pointingPortchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.10.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Pointing Port Index
Name
pointingPortIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.10.1.2
Description
Defines the index of the pointing ports in this chassis.
Syntax
DellObjectRange
Access
Read-only
Pointing Port State Capabilities
Name
pointingPortStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1000.10.3
Description
Defines the capabilities of the pointing port.
Syntax
DellStateCapabilities
Access
Read-only
230
Port Group
book.book Page 231 Wednesday, March 6, 2013 12:37 AM
Pointing Port State Settings
Name
pointingPortStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1000.10.4
Description
Defines the state and settings of the pointing port.
Syntax
DellStateSettings
Access
Read-write
Pointing Port Status
Name
pointingPortStatus
Object ID
1.3.6.1.4.1.674.10892.1.1000.10.5
Description
Defines the status of the pointing port.
Syntax
DellStatus
Access
Read-only
Pointing Port Security State
Name
pointingPortSecurityState
Object ID
1.3.6.1.4.1.674.10892.1.1000.10.6
Description
Defines the security settings of the pointing port.
Syntax
DellPortSecurityState
Access
Read-only
Pointing Port Connector Type
Name
pointingPortConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.10.7
Description
Defines the connector type of the pointing port.
Syntax
DellPointingPortConnectorType (See Table 12-1)
Access
Read-only
Port Group
231
book.book Page 232 Wednesday, March 6, 2013 12:37 AM
Pointing Port Name
Name
pointingPortName
Object ID
1.3.6.1.4.1.674.10892.1.1000.10.8
Description
Defines the name of the pointing port.
Syntax
DellString
Access
Read-only
Pointing Port BIOS Connector Type
Name
pointingPortBIOSConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.10.9
Description
Defines the basic input/output system (BIOS) connector type of
the pointing port.
Syntax
DellGenericPortConnectorType
Access
Read-only
Keyboard Port Table
Name
keyboardPortTable
Object ID
1.3.6.1.4.1.674.10892.1.1000.20
Description
Defines the Keyboard Port Table.
Syntax
IntegerKeyboardPortTableEntry
Access
Not accessible
Keyboard Port Table Entry
Name
keyboardPortTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1000.20.1
Description
Defines the Keyboard Port Table entry.
Syntax
KeyboardPortTableEntry
Access
Not accessible
Index
keyboardPortchassisIndex, keyboardPortIndex
232
Port Group
book.book Page 233 Wednesday, March 6, 2013 12:37 AM
Keyboard Port Chassis Index
Name
keyboardPortchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.20.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Keyboard Port Index
Name
keyboardPortIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.20.1.2
Description
Defines the index of the keyboard ports in this chassis.
Syntax
DellObjectRange
Access
Read-only
Keyboard Port State Capabilities
Name
keyboardPortStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1000.20.1.3
Description
Defines the capabilities of the keyboard port.
Syntax
DellStateCapabilities
Access
Read-only
Keyboard Port State Settings
Name
keyboardPortStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1000.20.1.4
Description
Defines the state and settings of the keyboard port.
Syntax
DellStateSettings
Access
Read-only
Port Group
233
book.book Page 234 Wednesday, March 6, 2013 12:37 AM
Keyboard Port Status
Name
keyboardPortStatus
Object ID
1.3.6.1.4.1.674.10892.1.1000.20.1.5
Description
Defines the status of the keyboard port.
Syntax
DellStatus
Access
Read-only
Keyboard Port Security State
Name
keyboardPortSecurityState
Object ID
1.3.6.1.4.1.674.10892.1.1000.20.1.6
Description
Defines the security settings of the keyboard port.
Syntax
DellPortSecurityState
Access
Read-only
Keyboard Port Connector Type
Name
keyboardPortConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.20.1.7
Description
Defines the connector type of the keyboard port.
Syntax
DellKeyboardPortConnectorType (See Table 12-2)
Access
Read-only
Keyboard Port Name
Name
keyboardPortName
Object ID
1.3.6.1.4.1.674.10892.1.1000.20.1.8
Description
Defines the name of the keyboard port.
Syntax
DellString
Access
Read-only
234
Port Group
book.book Page 235 Wednesday, March 6, 2013 12:37 AM
Keyboard Port BIOS Connector Type
Name
keyboardPortBIOSConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.20.1.9
Description
Defines the BIOS connector type of the keyboard port.
Syntax
DellGenericPortConnectorType
Access
Read-only
Processor Port Table
Name
processorPortTable
Object ID
1.3.6.1.4.1.674.10892.1.1000.30
Description
Defines the Processor Port Table.
Syntax
IntegerProcessorPortTableEntry
Access
Not accessible
Processor Port Table Entry
Name
processorPortTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1000.30.1
Description
Defines the Processor Port Table entry.
Syntax
ProcessorPortTableEntry
Access
Not accessible
Index
processorPortchassisIndex, processorPortIndex
Processor Port Chassis Index
Name
processorPortchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.30.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Port Group
235
book.book Page 236 Wednesday, March 6, 2013 12:37 AM
Processor Port Index
Name
processorPortIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.30.1.2
Description
Defines the index of the processor ports in this chassis.
Syntax
DellObjectRange
Access
Read-only
Processor Port State Capabilities
Name
processorPortStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1000.30.1.3
Description
Defines the capabilities of the processor port.
Syntax
DellStateCapabilities
Access
Read-only
Processor Port State Settings
Name
processorPortStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1000.30.1.4
Description
Defines the state and settings of the processor port.
Syntax
DellStateSettings
Access
Read-write
Processor Port Status
Name
processorPortStatus
Object ID
1.3.6.1.4.1.674.10892.1.1000.30.1.5
Description
Defines the status of the processor port.
Syntax
DellStatus
Access
Read-only
236
Port Group
book.book Page 237 Wednesday, March 6, 2013 12:37 AM
Processor Port Security State
Name
processorPortSecurityState
Object ID
1.3.6.1.4.1.674.10892.1.1000.30.1.6
Description
Defines the security settings of the processor port.
Syntax
DellPortSecurityState
Access
Read-only
Processor Port Connector Type
Name
processorPortConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.30.1.7
Description
Defines the connector type of the processor port.
Syntax
DellProcessorPortConnectorType (See Table 12-3)
Access
Read-only
Processor Port Name
Name
processorPortName
Object ID
1.3.6.1.4.1.674.10892.1.1000.30.1.8
Description
Defines name of the processor port.
Syntax
DellString
Access
Read-only
Processor Port BIOS Connector Type
Name
processorPortBIOSConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.30.1.9
Description
Defines the BIOS connector type of the processor port.
Syntax
DellGenericPortConnectorType
Access
Read-only
Port Group
237
book.book Page 238 Wednesday, March 6, 2013 12:37 AM
Memory Device Port Table
Name
memoryDevicePortTable
Object ID
1.3.6.1.4.1.674.10892.1.1000.40
Description
Defines the Memory Device Port Table.
Syntax
IntegerMemoryDevicePortTableEntry
Access
Not accessible
Memory Device Port Table Entry
Name
memoryDevicePortTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1000.40.1
Description
Defines the Memory Device Port Table entry.
Syntax
MemoryDevicePortTableEntry
Access
Not accessible
Index
memoryDevicePortchassisIndex, memoryDevicePortIndex
Memory Device Port Chassis Index
Name
memoryDevicePortchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.40.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Memory Device Port Index
Name
memoryDevicePortIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.40.1.2
Description
Defines the index of the memory device port in this chassis.
Syntax
DellObjectRange
Access
Read-only
238
Port Group
book.book Page 239 Wednesday, March 6, 2013 12:37 AM
Memory Device Port State Capabilities
Name
memoryDevicePortStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1000.40.1.3
Description
Defines the capabilities of the memory device port.
Syntax
DellStateCapabilities
Access
Read-only
Memory Device Port State Settings
Name
memoryDevicePortStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1000.40.1.4
Description
Defines the state and settings of the memory device port.
Syntax
DellStateSettings
Access
Read-write
Memory Device Port Status
Name
memoryDevicePortStatus
Object ID
1.3.6.1.4.1.674.10892.1.1000.40.1.5
Description
Defines the status of the memory device port.
Syntax
DellStatus
Access
Read-only
Memory Device Port Security State
Name
memoryDevicePortSecurityState
Object ID
1.3.6.1.4.1.674.10892.1.1000.40.1.6
Description
Defines the security settings of the memory device port.
Syntax
DellPortSecurityState
Access
Read-only
Port Group
239
book.book Page 240 Wednesday, March 6, 2013 12:37 AM
Memory Device Port Connector Type
Name
memoryDevicePortConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.40.1.7
Description
Defines the connector type of the memory device port.
Syntax
DellMemoryDevicePortConnectorType (See Table 12-4)
Access
Read-only
Memory Device Port Name
Name
memoryDevicePortName
Object ID
1.3.6.1.4.1.674.10892.1.1000.40.1.8
Description
Defines the name of the memory device port.
Syntax
DellString
Access
Read-only
Memory Device Port BIOS Connector Type
Name
memoryDevicePortBIOSConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.40.1.9
Description
Defines the BIOS connector type of the memory device port.
Syntax
DellGenericPortConnectorType
Access
Read-only
Memory Device Port Physical Memory Array Index Reference
Name
memoryDevicePortPhysicalMemoryArrayIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1000.40.1.10
Description
Defines the index to the associated physical memory array.
Syntax
DellUnsigned32BitRange
Access
Read-only
240
Port Group
book.book Page 241 Wednesday, March 6, 2013 12:37 AM
Memory Device Port Physical Memory Card Index Reference
Name
memoryDevicePortPhysicalMemoryCardIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1000.40.1.11
Description
Defines the index (one-based) of the Physical Memory Card Table
entry for the physical memory card with the same chassis index that
this memory device port is associated with (if any).
Syntax
DellUnsigned32BitRange
Access
Read-only
Monitor Port Table
Name
monitorPortTable
Object ID
1.3.6.1.4.1.674.10892.1.1000.50
Description
Defines the Monitor Port Table.
Syntax
IntegerMonitorPortTableEntry
Access
Not accessible
Monitor Port Table Entry
Name
monitorPortTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1000.50.1
Description
Defines the Monitor Port Table entry.
Syntax
MonitorPortTableEntry
Access
Not accessible
Index
monitorPortchassisIndex, monitorPortIndex
Monitor Port Chassis Index
Name
monitorPortchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.50.1.1
Description
Defines the index (one-based) of this chassis
Syntax
DellObjectRange
Access
Read-only
Port Group
241
book.book Page 242 Wednesday, March 6, 2013 12:37 AM
Monitor Port Index
Name
monitorPortIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.50.1.2
Description
Defines the index of the monitor ports in this chassis.
Syntax
DellObjectRange
Access
Read-only
Monitor Port State Capabilities
Name
monitorPortStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1000.50.1.3
Description
Defines the capabilities of the monitor port.
Syntax
DellStateCapabilities
Access
Read-only
Monitor Port State Settings
Name
monitorPortStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1000.50.1.4
Description
Defines the state of the monitor port.
Syntax
DellStateSettings
Access
Read-write
Monitor Port Status
Name
monitorPortStatus
Object ID
1.3.6.1.4.1.674.10892.1.1000.50.1.5
Description
Defines the status of the monitor port.
Syntax
DellStatus
Access
Read-only
242
Port Group
book.book Page 243 Wednesday, March 6, 2013 12:37 AM
Monitor Port Security State
Name
monitorPortSecurityState
Object ID
1.3.6.1.4.1.674.10892.1.1000.50.1.6
Description
Defines the security settings of the monitor port.
Syntax
DellPortSecurityState
Access
Read-only
Monitor Port Connector Type
Name
monitorPortConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.50.1.7
Description
Defines the connector type of the monitor port.
Syntax
DellMonitorPortConnectorTypes (See Table 12-5)
Access
Read-only
Monitor Port Name
Name
monitorPortName
Object ID
1.3.6.1.4.1.674.10892.1.1000.50.1.8
Description
Defines the name of the monitor port.
Syntax
DellString
Access
Read-only
Monitor Port BIOS Connector Type
Name
monitorPortBIOSConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.50.1.9
Description
Defines the name of the BIOS connector type of the monitor port.
Syntax
DellGenericPortConnectorType
Access
Read-only
Port Group
243
book.book Page 244 Wednesday, March 6, 2013 12:37 AM
Small Computer System Interface (SCSI) Port Table
Name
sCSIPortTable
Object ID
1.3.6.1.4.1.674.10892.1.1000.60
Description
Defines the SCSI Port Table.
Syntax
IntegerSCSIPortTableEntry
Access
Not accessible
SCSI Port Table Entry
Name
sCSIPortTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1000.60.1
Description
Defines the SCSI Port Table entry.
Syntax
SCSIPortTableEntry
Access
Not accessible
Index
sCSIPortchassisIndex, sCSIPortIndex
SCSI Port Chassis Index
Name
sCSIPortchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.60.1.1
Description
Defines the index (one-based) of this chassis
Syntax
DellObjectRange
Access
Read-only
SCSI Port Index
Name
sCSIPortIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.60.1.2
Description
Defines the index of the SCSI ports in this chassis.
Syntax
DellObjectRange
Access
Read-only
244
Port Group
book.book Page 245 Wednesday, March 6, 2013 12:37 AM
SCSI Port State Capabilities
Name
sCSIPortStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1000.60.1.3
Description
Defines the capabilities of the SCSI port.
Syntax
DellStateCapabilities
Access
Read-only
SCSI Port State Settings
Name
DellStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1000.60.1.4
Description
Defines the state and settings of the SCSI port.
Syntax
DellStatus
Access
Read-write
SCSI Port Status
Name
sCSIPortStatus
Object ID
1.3.6.1.4.1.674.10892.1.1000.60.1.5
Description
Defines the status of the SCSI port.
Syntax
DellStatus
Access
Read-only
SCSI Port Security State
Name
sCSIPortSecurityState
Object ID
1.3.6.1.4.1.674.10892.1.1000.60.1.6
Description
Defines the security settings of the SCSI port.
Syntax
DellPortSecurityState
Access
Read-only
Port Group
245
book.book Page 246 Wednesday, March 6, 2013 12:37 AM
SCSI Port Connector Type
Name
sCSIPortConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.60.1.7
Description
Defines the connector type of the SCSI port.
Syntax
DellSCSIPortConnectorType (See Table 12-6)
Access
Read-only
SCSI Port Name
Name
sCSIPortName
Object ID
1.3.6.1.4.1.674.10892.1.1000.60.1.8
Description
Defines the name of the SCSI port.
Syntax
DellString
Access
Read-only
SCSI Port BIOS Connector Type
Name
sCSIPortBIOSConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.60.1.9
Description
Defines the BIOS connector type of the SCSI port.
Syntax
DellGenericPortConnectorType
Access
Read-only
Parallel Port Table
Name
parallelPortTable
Object ID
1.3.6.1.4.1.674.10892.1.1000.70
Description
Defines the Parallel Port Table.
Syntax
IntegerParallelPortTableEntry
Access
Not accessible
246
Port Group
book.book Page 247 Wednesday, March 6, 2013 12:37 AM
Parallel Port Table Entry
Name
parallelPortTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1
Description
Defines the Parallel Port Table entry.
Syntax
ParallelPortTableEntry
Access
Not accessible
Index
parallelPortchassisIndex, parallelPortIndex
Parallel Port Chassis Index
Name
parallelPortchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Parallel Port Index
Name
parallelPortIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1.2
Description
Defines the index of the parallel ports in this chassis.
Syntax
DellObjectRange
Access
Read-only
Parallel Port State Capabilities
Name
parallelPortStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1.3
Description
Defines the capabilities of the parallel port.
Syntax
DellStateSettings
Access
Read-write
Port Group
247
book.book Page 248 Wednesday, March 6, 2013 12:37 AM
Parallel Port State Settings
Name
parallelPortStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1.4
Description
Defines the state and settings of the parallel port.
Syntax
DellStateSettings
Access
Read-write
Parallel Port Status
Name
parallelPortStatus
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1.5
Description
Defines the status of the parallel port.
Syntax
DellStatus
Access
Read-only
Parallel Port Security State
Name
DellPortSecurityState
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1.6
Description
Defines the security state of the parallel port.
Syntax
DellStatus
Access
Read-only
Parallel Port Connector Type
Name
parallelPortConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1.7
Description
Defines the connector type of the parallel port.
Syntax
DellParallelPortConnectorType
Access
Read-only
248
Port Group
book.book Page 249 Wednesday, March 6, 2013 12:37 AM
Parallel Port Name
Name
parallelPortName
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1.8
Description
Defines the name of the parallel port.
Syntax
DellString
Access
Read-only
Parallel Port Connector Pin Out
Name
parallelPortConnectorPinOut
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1.9
Description
Defines the pinout of the parallel port.
Syntax
DellParallelPortConnectorPinout
Access
Read-only
Parallel Port Capabilities Unique
Name
parallelPortCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1.10
Description
Defines the capabilities of the parallel port.
Syntax
DellParallelPortConnectorPinout
Access
Read-only
Parallel Port Base I/O Address
Name
parallelPortBaseIOAddress
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1.11
Description
Defines the Base Input/Output (I/O) address of the parallel port.
Syntax
DellUnsigned64BitRange
Access
Read-only
Port Group
249
book.book Page 250 Wednesday, March 6, 2013 12:37 AM
Parallel Port IRQ Level
Name
parallelPortIRQLevel
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1.12
Description
Defines the Interrupt Request Level (IRQ) of the parallel port.
Syntax
DellUnsigned8BitRange
Access
Read-only
Parallel Port DMA Support
Name
parallelPortDMASupport
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1.13
Description
Defines if direct memory access (DMA) is supported by the
parallel port.
Syntax
DellBoolean
Access
Read-only
Serial Port Table
Name
serialPortTable
Object ID
1.3.6.1.4.1.674.10892.1.1000.80
Description
Defines the Serial Port Table.
Syntax
IntegerSerialPortTableEntry
Access
Not accessible
Serial Port Table Entry
Name
serialPortTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1000.80.1
Description
Defines the Serial Port Table entry.
Syntax
SerialPortTableEntry
Access
Not accessible
Index
serialPortchassisIndex, serialPortIndex
250
Port Group
book.book Page 251 Wednesday, March 6, 2013 12:37 AM
Serial Port Chassis Index
Name
serialPortchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.80.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Serial Port Index
Name
serialPortIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.80.1.2
Description
Defines the index of the serial ports in this chassis.
Syntax
DellObjectRange
Access
Read-only
Serial Port State Capabilities
Name
serialPortStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1000.80.1.3
Description
Defines the capabilities of the serial port.
Syntax
DellStateCapabilities
Access
Read-only
Serial Port State Settings
Name
serialPortStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1000.80.1.4
Description
Defines the state and settings of the serial port.
Syntax
DellStateSettings
Access
Read-write
Port Group
251
book.book Page 252 Wednesday, March 6, 2013 12:37 AM
Serial Port Status
Name
serialPortStatus
Object ID
1.3.6.1.4.1.674.10892.1.1000.80.1.5
Description
Defines the status of the serial port.
Syntax
DellStatus
Access
Read-only
Serial Port Security State
Name
serialPortSecurityState
Object ID
1.3.6.1.4.1.674.10892.1.1000.80.1.6
Description
Defines the security settings of the serial port.
Syntax
DellPortSecurityState
Access
Read-only
Serial Port Connector Type
Name
serialPortConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.80.1.7
Description
Defines connector type of the serial port.
Syntax
DellSerialPortConnectorType
Access
Read-only
Serial Port Name
Name
serialPortName
Object ID
1.3.6.1.4.1.674.10892.1.1000.80.1.8
Description
Defines the name of the serial port.
Syntax
DellString
Access
Read-only
252
Port Group
book.book Page 253 Wednesday, March 6, 2013 12:37 AM
Serial Port Maximum Speed
Name
serialPortMaximumSpeed
Object ID
1.3.6.1.4.1.674.10892.1.1000.80.1.9
Description
Defines the maximum speed the serial interface can support in
bits per second (bps).
Syntax
DellUnsigned32BitRange
Access
Read-only
Serial Port Capabilities Unique
Name
serialPortCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1000.80.1.10
Description
Defines additional capabilities of the serial port.
Syntax
DellSerialPortCapabilitiesUnique
Access
Read-only
Serial Port Base I/O Address
Name
serialPortBaseIOAddress
Object ID
1.3.6.1.4.1.674.10892.1.1000.80.1.11
Description
Defines the base I/O address of the serial port.
Syntax
DellUnsigned64BitRange
Access
Read-only
Serial Port IRQ Level
Name
serialPortIRQLevel
Object ID
1.3.6.1.4.1.674.10892.1.1000.80.1.12
Description
Defines the IRQ of the serial port.
Syntax
DellUnsigned8BitRange
Access
Read-only
Port Group
253
book.book Page 254 Wednesday, March 6, 2013 12:37 AM
Universal Serial Bus (USB) Port Table
Name
uSBPortTable
Object ID
1.3.6.1.4.1.674.10892.1.1000.90
Description
Defines the USB Port Table.
Syntax
IntegerUSBPortTableEntry
Access
Not accessible
USB Port Table Entry
Name
uSBPortTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1000.90.1
Description
Defines the USB Port Table entry.
Syntax
USBPortTableEntry
Access
Not accessible
Index
uSBPortchassisIndex, uSBPortIndex
USB Port Chassis Index
Name
uSBPortchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.90.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
USB Port Index
Name
uSBPortIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.90.1.2
Description
Defines the index of the USB ports in this chassis
Syntax
DellObjectRange
Access
Read-only
254
Port Group
book.book Page 255 Wednesday, March 6, 2013 12:37 AM
USB Port State Capabilities
Name
uSBPortStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1000.90.1.3
Description
Defines the capabilities of the USB port.
Syntax
DellStateCapabilities
Access
Read-only
USB Port State Settings
Name
uSBPortStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1000.90.1.4
Description
Defines the state and settings of the USB port.
Syntax
DellStateSettings
Access
Read-write
USB Port Status
Name
uSBPortStatus
Object ID
1.3.6.1.4.1.674.10892.1.1000.90.1.5
Description
Defines the state of the USB port.
Syntax
DellStatus
Access
Read-only
USB Port Security State
Name
uSBPortSecurityState
Object ID
1.3.6.1.4.1.674.10892.1.1000.90.1.6
Description
Defines the security settings of the USB port.
Syntax
DellPortSecurityState
Access
Read-only
Port Group
255
book.book Page 256 Wednesday, March 6, 2013 12:37 AM
USB Port Connector Type
Name
uSBPortConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.90.1.7
Description
Defines the connector type of the USB port.
Syntax
DellUSBPortConnectorType
Access
Read-only
USB Port Name
Name
uSBPortName
Object ID
1.3.6.1.4.1.674.10892.1.1000.90.1.8
Description
Defines the name of the USB port.
Syntax
DellString
Access
Read-only
USB Port BIOS Connector Type
Name
uSBPortBIOSConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.90.1.9
Description
Defines the BIOS connector type of the USB port.
Syntax
DellGenericPortConnectorType
Access
Read-only
256
Port Group
book.book Page 257 Wednesday, March 6, 2013 12:37 AM
Port Group Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 12-1.
Pointing Port Connector Type
Variable Name: DellPointingPortConnectorType
Data Type: Integer
Possible Data Values
Meaning of Data Value
connectorPortTypeIsOther(1)
The pointing port connector type is
not one of the following:
connectorPortTypeIsUnknown(2)
The pointing port connector type is
unknown.
connectorPortTypeIsSerial(3)
The pointing port connector type is
serial.
connectorPortTypeIsPS2(4)
The pointing port connector type is a
Personal System/2 (PS/2).
connectorPortTypeIsInfrared(5)
The pointing port connector type is
infrared.
connectorPortTypeIsHPHIL(6)
The pointing port connector type is
HP-HIL.
connectorPortTypeIsBusMouse(7)
The pointing port connector type is a
bus mouse.
connectorPortTypeIsADB(8)
The pointing port connector type is
ADB.
connectorPortTypeIsDB9(9)
The pointing port connector type is
nine-pin DB-9.
connectorPortTypeIsMicroDIN(10)
The pointing port connector type is
micro Deutsche Industrie Norm
(DIN).
connectorPortTypeIsAccessBusUSB
(11)
The pointing port connector type is
Access Bus USB.
connectorPortTypeIsPC98(12)
The port connector type is a PC-98.
Port Group
257
book.book Page 258 Wednesday, March 6, 2013 12:37 AM
Table 12-2. Keyboard Port Connector Types
Variable Name: DellKeyboardPortConnectorType
Data Type: Integer
Possible Data Values
Meaning of Data Value
connectorPortTypeIsOther(1)
The keyboard port connector
type is not one of the following:
connectorPortTypeIsUnknown(2)
The keyboard port connector
type is unknown.
connectorPortTypeIsMiniDIN(3)
The keyboard port connector
type is a mini DIN.
connectorPortTypeIsMicroDIN(4)
The keyboard port connector
type is a MicroDIN.
connectorPortTypeIsPS2(5)
The keyboard port connector
type is PS/2.
connectorPortTypeIsInfrared(6)
The keyboard port connector
type is infrared.
connectorPortTypeIsHPHIL(7)
The keyboard port connector
type is HP-HIL.
connectorPortTypeIsDB9(8)
The keyboard port connector
type is DB-9.
connectorPortTypeIsAccessBusUSB(9) The keyboard port connector
type is bus USB.
connectorPortTypeIsPC98(10)
258
Port Group
The keyboard port connector
type is PC-98.
book.book Page 259 Wednesday, March 6, 2013 12:37 AM
Table 12-3.
Processor Port Connector Types
Variable Name: DellProcessorPortConnectorType
Data Type: Integer
Possible Data Values
Meaning of Data Value
connectorPortTypeIsOther(1)
The processor port connector
type is not one of the
following:
connectorPortTypeIsUnknown(2)
The processor port connector
type is unknown.
connectorPortTypeIsDaughterdBoard(3)
The processor port connector
type is a daughter board.
connectorPortTypeIsZIFSocket(4)
The processor port connector
type is a zero insertion force
(ZIF) socket.
connectorPortTypeIsAPiggyBackBoard(5) The processor port connector
type is a replacement
piggyback board.
connectorPortTypeIsNone(6)
There is no processor port
connector; processor is
soldered in place.
connectorPortTypeIsLIFSocket(7)
The processor port connector
type is a low insertion force
(LIF) socket.
connectorPortTypeIsSlot1(8)
The processor port connector
type is a slot one.
connectorPortTypeIsSlot2(9)
The processor port connector
type is a slot two.
connectorPortTypeIs370PinSocket(10)
The processor port connector
type is a 370 pin socket.
Port Group
259
book.book Page 260 Wednesday, March 6, 2013 12:37 AM
Table 12-4. Memory Device Port Connector Types
Variable Name: DellMemoryDevicePortConnectorType
Data Type: Integer
Possible Data Value
Meaning of Data Value
connectorPortTypeIsOther(1)
The memory device port
connector type is not one of
the following:
connectorPortTypeIsUnknown(2)
The memory device port
connector type is unknown.
connectorPortTypeIsSIMM(3)
The memory device port
connector type is a single
in-line memory module
(SIMM).
connectorPortTypeIsSIP(4)
The memory device port
connector type is a SIP.
connectorPortTypeIsAChip(5)
The memory device port
connector type is a chip.
connectorPortTypeIsDIP(6)
The memory device port
connector type is a dual
in-line package (DIP).
connectorPortTypeIsZIP(7)
The memory device port
connector type is a ZIP.
connectorPortTypeIsAProprietaryCard(8) The memory device port
connector type is a
proprietary card.
connectorPortTypeIsDIMM(9)
The memory device port
connector type is a dual
in-line memory module
(DIMM).
connectorPortTypeIsTSOP(10)
The memory device port
connector type is a TSOP.
connectorPortTypeIsARowOfChips(11)
The memory device port
connector type is a row of
chips.
260
Port Group
book.book Page 261 Wednesday, March 6, 2013 12:37 AM
Table 12-4.
Memory Device Port Connector Types (continued)
Variable Name: DellMemoryDevicePortConnectorType
Data Type: Integer
Possible Data Value
Meaning of Data Value
connectorPortTypeIsRIMM(12)
The memory device port
connector type is a Rambus
Inline Memory Module
(RIMM).
connectorPortTypeIsSODIMM(13)
The memory device port
connector type is a small
outline, dual in-line
memory module
(SODIMM).
connectorPortTypeIsSRIMM(14)
The memory device port
connector type is a SRIMM.
Table 12-5.
Monitor Port Connector Types
Variable Name: DellMonitorPortConnectorType
Data Type: Integer
Possible Data Values
Meaning of Data Value
connectorPortTypeIsOther(1)
The monitor port connector type
is not one of the following:
connectorPortTypeIsUnknown(2)
The monitor port connector type
is unknown.
connectorPortTypeIsDB15PinMale(3)
The monitor port connector type
is a male DB-15.
connectorPortTypeIsDB15PinFemale(4) The monitor port connector type
is a female DB-15.
Port Group
261
book.book Page 262 Wednesday, March 6, 2013 12:37 AM
Table 12-6. SCSI Port Connector Types
Variable Name: DellSCSIPortConnectorType
Data Type: Integer
Possible Data Values
Meaning of Data Value
connectorPortTypeIsOther(1)
The SCSI port connector type
is not one of the following:
connectorPortTypeIsUnknown(2)
The SCSI port connector type
is unknown.
connectorPortTypeIsDIN25pin(3)
The SCSI port connector type
is a DIN 25-pin.
connectorPortTypeIsDIN50pin(4)
The SCSI port connector type
is a DIN 50-pin.
connectorPortTypeIsDIN68pin(5)
The SCSI port connector type
is a DIN 68-pin.
262
Port Group
book.book Page 263 Wednesday, March 6, 2013 12:37 AM
13
Device Group
The Device Group provides information about different types of pointing,
keyboard, processor, cache, memory, and peripheral component interconnect
(PCI) devices. Variables in this group cover information about type, settings,
configuration, manufacturer, address or location, and if applicable, the speed
of the device.
Device Tables
The following management information base (MIB) tables define objects in
the Device Group:
•
"Pointing Device Table" on page 264
•
"Keyboard Device Table" on page 266
•
"Processor Device Table" on page 269
•
"Processor Device Status Table" on page 277
•
"Cache Device Table" on page 279
•
"Memory Device Table" on page 285
•
"Memory Device Mapped Address Table" on page 293
•
"Generic Device Table" on page 296
•
"PCI Device Table" on page 299
•
"PCI Device Configuration Space Table" on page 302
•
"Network Device Table" on page 305
•
"Managed System Services Device Table" on page 313
•
"SD Card Unit Table" on page 315
•
"SD Card Device Table" on page 318
Device Group
263
book.book Page 264 Wednesday, March 6, 2013 12:37 AM
Pointing Device Table
Name
pointingDeviceTable
Object ID
1.3.6.1.4.1.674.10892.1.1100.10
Description
Defines the Pointing Device Table. This group of objects
references the Pointing Port Index (See Section 12).
Syntax
SEQUENCE OF PointingDeviceTableEntry
Access
Not accessible
Pointing Device Table Entry
Name
pointingDeviceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1100.10.1
Description
Defines the Pointing Device Table entry.
Syntax
PointingDeviceTableEntry
Access
Not accessible
Index
pointingDevicechassisIndex, pointingDeviceIndex
Pointing Device Chassis Index
Name
pointingDevicechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.10.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Pointing Device Index
Name
pointingDeviceIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.10.1.2
Description
Defines the index of the pointing device in this chassis.
Syntax
DellObjectRange
Access
Read-only
264
Device Group
book.book Page 265 Wednesday, March 6, 2013 12:37 AM
Pointing Device State Capabilities
Name
pointingDeviceStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1100.10.1.3
Description
Defines the capabilities of the pointing device.
Syntax
DellStateCapabilities
Access
Read-only
Pointing Device State Settings
Name
pointingDeviceStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1100.10.1.4
Description
Defines the state of the pointing device.
Syntax
DellStateSettings
Access
Read-write
Pointing Device Status
Name
pointingDeviceStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.10.1.5
Description
Defines the status of the pointing device.
Syntax
DellStatus
Access
Read-only
Pointing Port Index Reference
Name
pointingPortIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1100.10.1.6
Description
Defines the index to the pointing port in this chassis.
Syntax
DellObjectRange
Access
Read-only
Device Group
265
book.book Page 266 Wednesday, March 6, 2013 12:37 AM
Pointing Device Type
Name
pointingDeviceType
Object ID
1.3.6.1.4.1.674.10892.1.1100.10.1.7
Description
Defines the type of the pointing device.
Syntax
DellPointingDeviceType (See Table 13-1)
Access
Read-only
Pointing Device Number of Buttons
Name
pointingDeviceNumberofButtons
Object ID
1.3.6.1.4.1.674.10892.1.1100.10.1.8
Description
Defines the number of buttons on the pointing device.
Syntax
DellUnsigned8BitRange
Access
Read-only
Keyboard Device Table
Name
keyboardDeviceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1100.20
Description
Defines the Keyboard Device Table. This table references the
Keyboard Port Index (See Section 12).
Syntax
SEQUENCE OF KeyboardDeviceTableEntry
Access
Not accessible
Keyboard Device Table Entry
Name
keyboardDeviceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1100.20.1
Description
Defines the Keyboard Device Table entry.
Syntax
KeyboardDeviceTableEntry
Access
Not accessible
Index
keyboardDevicechassisIndex, keyboardDeviceIndex
266
Device Group
book.book Page 267 Wednesday, March 6, 2013 12:37 AM
Keyboard Device Chassis Index
Name
keyboardDevicechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.20.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Keyboard Device Index
Name
keyboardDeviceIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.20.1.2
Description
Defines the index of the keyboard device for this chassis.
Syntax
DellObjectRange
Access
Read-only
Keyboard Device State Capabilities
Name
keyboardDeviceStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1100.20.1.3
Description
Defines the capabilities of the keyboard device.
Syntax
DellStateCapabilities
Access
Read-only
Keyboard Device State Settings
Name
keyboardDeviceStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1100.20.1.4
Description
Defines the state of the keyboard device.
Syntax
DellStatesSettings
Access
Read-write
Device Group
267
book.book Page 268 Wednesday, March 6, 2013 12:37 AM
Keyboard Device Status
Name
keyboardDeviceStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.20.1.5
Description
Defines the status of the keyboard device.
Syntax
DellStatus
Access
Read-only
Keyboard Port Index Reference
Name
keyboardPortIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1100.20.1.6
Description
Defines the index to the associated the keyboard port in
this chassis.
Syntax
DellStatus
Access
Read-only
Keyboard Device Type Name
Name
keyboardDeviceTypeName
Object ID
1.3.6.1.4.1.674.10892.1.1100.20.1.7
Description
Defines the name of the keyboard type.
Syntax
DellString
Access
Read-only
Keyboard Device Layout Name
Name
keyboardDeviceLayoutName
Object ID
1.3.6.1.4.1.674.10892.1.1100.20.1.8
Description
Defines the name of the keyboard layout.
Syntax
DellString
Access
Read-only
268
Device Group
book.book Page 269 Wednesday, March 6, 2013 12:37 AM
Processor Device Table
Name
processorDeviceTable
Object ID
1.3.6.1.4.1.674.10892.1.1100.30
Description
Defines the Processor Device Table.
Syntax
SEQUENCE OF ProcessorDeviceTableEntry
Access
Not accessible
Processor Device Table Entry
Name
processorDeviceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1
Description
Defines the Processor Device Table entry.
Syntax
ProcessorDeviceTableEntry
Access
Not accessible
Index
processorDevicechassisIndex, processorDeviceIndex
Processor Device Chassis Index
Name
processorDevicechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Processor Device Index
Name
processorDeviceIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.2
Description
Defines the index of the processor device in this chassis.
Syntax
DellObjectRange
Access
Read-only
Device Group
269
book.book Page 270 Wednesday, March 6, 2013 12:37 AM
Processor Device State Capabilities
Name
processorDeviceStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.3
Description
Defines the capabilities of the processor device.
Syntax
DellStateCapabilities
Access
Read-only
Processor Device State Settings
Name
processorDeviceStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.4
Description
Defines the state of the processor device.
Syntax
DellStateSettings
Access
Read-write
Processor Device Status
Name
processorDeviceStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.5
Description
Defines the status of the processor device.
Syntax
DellStatus
Access
Read-only
Processor Port Index Reference
Name
processorPortIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.6
Description
Defines the index to the associated processor port in this
chassis.
Syntax
DellObjectRange
Access
Read-only
270
Device Group
book.book Page 271 Wednesday, March 6, 2013 12:37 AM
Processor Device Type
Name
processorDeviceType
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.7
Description
Defines the type of processor device.
Syntax
DellProcessorDeviceType (See Table 13-4)
Access
Read-only
Processor Device Manufacturer Name
Name
processorDeviceManufacturerName
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.8
Description
Defines the name of manufacturer of the processor device.
Syntax
DellString
Access
Read-only
Processor Device Status State
Name
processorDeviceStatusState
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.9
Description
Defines the status state of the processor device.
Syntax
DellProcessorDeviceStatusState (See Table 13-2)
Access
Read-only
Processor Device Family
Name
processorDeviceFamily
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.10
Description
Defines the family of the processor device.
Syntax
DellProcessorDeviceFamily (See Table )
Access
Read-only
Device Group
271
book.book Page 272 Wednesday, March 6, 2013 12:37 AM
Processor Device Maximum Speed
Name
processorDeviceMaximumSpeed
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.11
Description
Defines the maximum speed of the processor device in
megahertz (MHz). A zero (0) indicates that the speed is
unknown.
Syntax
DellUnsigned32BitRange
Access
Read-only
Processor Device Current Speed
Name
processorDeviceCurrentSpeed
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.12
Description
Defines the current speed of the processor device in MHz. A
zero (0) indicates that the speed is unknown.
Syntax
DellUnsigned32BitRange
Access
Read-only
Processor Device External Clock Speed
Name
processorDeviceExternalClockSpeed
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.13
Description
Defines the speed of the external clock (the front-side bus
speed) for the processor device in MHz. A zero (0) indicates
that the speed is unknown.
Syntax
DellUnsigned32BitRange
Access
Read-only
272
Device Group
book.book Page 273 Wednesday, March 6, 2013 12:37 AM
Processor Device Voltage
Name
processorDeviceVoltage
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.14
Description
Defines the voltage powering the processor device in millivolts.
A zero (0) indicates the speed is unknown.
Syntax
DellSigned32BitRange
Access
Read-only
Processor Device Upgrade Information
Name
processorDeviceUpgradeInformation
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.15
Description
Defines the processor upgrade information for the processor device.
Syntax
DellProcessorUpgradeInformation (See Table 13-5)
Access
Read-only
Processor Device Version Name
Name
processorDeviceVersionName
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.16
Description
Defines the version name of the processor device.
Syntax
DellString
Access
Read-only
Device Group
273
book.book Page 274 Wednesday, March 6, 2013 12:37 AM
Processor Device Core Count
Name
processorDeviceCoreCount
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.17
Description
Defines the number of processor cores detected for the
processor device.
Syntax
DellUnsigned32BitRange
Access
Read-only
Processor Device Core Enabled Count
Name
processorDeviceCoreEnabledCount
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.18
Description
Defines the number of processor cores enabled for the
processor device.
Syntax
DellUnsigned32BitRange
Access
Read-only
Processor Device Thread Count
Name
processorDeviceThreadCount
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.19
Description
Defines the number of processor threads detected for the
processor device.
Syntax
DellUnsigned32BitRange
Access
Read-only
274
Device Group
book.book Page 275 Wednesday, March 6, 2013 12:37 AM
Processor Device Characteristics
Name
processorDeviceCharacteristics
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.20
Description
This attribute defines characteristics of the processor device.
This attribute is a bit field where a bit has the meaning defined
below when set to 1 (one).
NOTE: Bits 2-15 need to be examined in the context of bit 1. If bit 1 is
set, the processor characteristics are unknown and bits 2-15
cannot be used to determine if the functions associated with the
bits are supported.
Bit Position
-------------Bit 0
Bit 1
Bit 2
Bit 3-15
Meaning if Set
-----------------Reserved
Unknown
64-bit capable
Reserved
Syntax
DellUnsigned16BitRange
Access
Read-only
Processor Device Extended Capabilities
Name
processorDeviceExtendedCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.21
Description
This attribute defines extended capabilities of the processor
device. This attribute is a bit field where a bit has the meaning
defined below when set to 1 (one).
Bit Position
---------------Bit 0
Bit 1
Bit 2
Bit 3
Meaning if Set
------------------Virtualization Technology (VT) supported
Demand-Based Switching (DBS) supported
eXecute Disable (XD) supported
Hyper-Threading (HT) supported
Syntax
DellUnsigned16BitRange
Access
Read-only
Device Group
275
book.book Page 276 Wednesday, March 6, 2013 12:37 AM
Processor Device Extended Settings
Name
processorDeviceExtendedSettings
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.22
Description
This attribute defines extended settings of the processor device.
This attribute is a bit field where a bit has the meaning defined
below when set to 1 (one).
Bit Position
--------------Bit 0
Bit 1
Bit 2
Bit 3
Meaning if Set
------------Virtualization Technology (VT) enabled
Demand Based Switching (DBS) enabled
eXecute Disable (XD) enabled
Hyper-Threading (HT) enabled
Syntax
DellUnsigned16BitRange
Access
Read-only
Processor Device Brand Name
Name
processorDeviceBrandName
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.23
Description
Defines the brand of the processor device.
Syntax
DellString
Access
Read-only
Processor Device Model Name
Name
processorDeviceModelName
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.24
Description
Defines the model of the processor device.
Syntax
DellString
Access
Read-only
276
Device Group
book.book Page 277 Wednesday, March 6, 2013 12:37 AM
Processor Device Stepping Name
Name
processorDeviceSteppingName
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.25
Description
Defines the stepping of the processor device.
Syntax
DellString
Access
Read-only
Processor Device Status Table
Name
processorDeviceStatusTable
Object ID
1.3.6.1.4.1.674.10892.1.1100.32
Description
Defines the Processor Device Status Table.
Syntax
SEQUENCE OF ProcessorDeviceStatusTableEntry
Access
Not accessible
Processor Device Status Table Entry
Name
processorDeviceStatusTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1100.32.1
Description
Defines the Processor Device Status Table Entry.
Syntax
ProcessorDeviceStatusTableEntry
Access
Not accessible
Index
processorDeviceStatusChassisIndex,
processorDeviceStatusIndex
Processor Device Status Chassis Index
Name
processorDeviceStatusChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.32.1.1
Description
Defines the index (one-based) of the associated chassis.
Syntax
DellObjectRange
Access
Read-only
Device Group
277
book.book Page 278 Wednesday, March 6, 2013 12:37 AM
Processor Device Status Index
Name
processorDeviceStatusIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.32.1.2
Description
Defines the index (one-based) of the processor device status
probe.
Syntax
DellObjectRange
Access
Read-only
Processor Device Status State Capabilities
Name
processorDeviceStatusStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1100.32.1.3
Description
Defines the state capabilities of the processor device status probe.
Syntax
DellStateCapabilities
Access
Read-only
Processor Device Status State Settings
Name
processorDeviceStatusStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1100.32.1.4
Description
Defines the state settings of the processor device status probe.
Syntax
DellStateSettings
Access
Read-write
Processor Device Status Status
Name
processorDeviceStatusStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.32.1.5
Description
Defines the status of the processor device status probe. This
status is joined into the processorDeviceStatus attribute.
Syntax
DellStatus
Access
Read-only
278
Device Group
book.book Page 279 Wednesday, March 6, 2013 12:37 AM
Processor Device Status Reading
Name
processorDeviceStatusReading
Object ID
1.3.6.1.4.1.674.10892.1.1100.32.1.6
Description
Defines the reading of the processor device status probe.
Syntax
DellProcessorDeviceStatusReading
Access
Read-only
Processor Device Status Location Name
Name
processorDeviceStatusLocationName
Object ID
1.3.6.1.4.1.674.10892.1.1100.32.1.7
Description
Defines the location name of the processor device status probe.
Syntax
DellString
Access
Read-only
Processor Device Status Port Index Reference
Name
processorDeviceStatusPortIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1100.32.1.8
Description
Defines the index (one-based) of the associated processor port
in the same chassis.
Syntax
DellObjectRange
Access
Read-only
Cache Device Table
Name
cacheDeviceTable
Object ID
1.3.6.1.4.1.674.10892.1.1100.40
Description
Defines the Cache Device Table.
Syntax
SEQUENCE OF CacheDeviceTableEntry
Access
Not accessible
Device Group
279
book.book Page 280 Wednesday, March 6, 2013 12:37 AM
Cache Device Table Entry
Name
cacheDeviceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1
Description
Defines the Cache Device Table entry.
Syntax
CacheDeviceTableEntry
Access
Not accessible
Index
cacheDevicechassisIndex, cacheDeviceIndex
Cache Device Chassis Index
Name
cacheDevicechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Cache Device Index
Name
cacheDeviceIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.2
Description
Defines the index of the cache device in this chassis.
Syntax
DellObjectRange
Access
Read-only
Cache Device State Capabilities
Name
cacheDeviceStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.3
Description
Defines the capabilities of the cache device.
Syntax
DellStateCapabilities
Access
Read-only
280
Device Group
book.book Page 281 Wednesday, March 6, 2013 12:37 AM
Cache Device State Settings
Name
cacheDeviceStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.4
Description
Defines the state of the cache device.
Syntax
DellStateSettings
Access
Read-write
Cache Device Status
Name
cacheDeviceStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.5
Description
Defines the status of the cache device.
Syntax
DellStatus
Access
Read-only
Cache Device Processor Device Index Reference
Name
cacheDeviceprocessorDeviceIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.6
Description
Defines the index number of the processor device with which
this cache device is associated.
Syntax
DellObjectRange
Access
Read-only
Cache Device Type
Name
cacheDeviceType
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.7
Description
Defines the type of cache device.
Syntax
DellCacheDeviceType (See Table 13-7)
Access
Read-only
Device Group
281
book.book Page 282 Wednesday, March 6, 2013 12:37 AM
Cache Device Location
Name
cacheDeviceLocation
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.8
Description
Defines the location of the cache device.
Syntax
DellCacheDeviceLocation (See Table 13-13)
Access
Read-only
Cache Device Status State
Name
cacheDeviceStatusState
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.9
Description
Defines the status state of the cache device.
Syntax
DellCacheDeviceStatusState (See Table 13-10)
Access
Read-only
Cache Device External Socket Name
Name
cacheDeviceExternalSocketName
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.10
Description
Defines the external socket name of the cache device, if the
cache is socketed.
Syntax
DellString
Access
Read-only
Cache Device Level
Name
cacheDeviceLevel
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.11
Description
Defines the level of the cache device.
Syntax
DellCacheDeviceLevel (See Table 13-8)
Access
Read-only
282
Device Group
book.book Page 283 Wednesday, March 6, 2013 12:37 AM
Cache Device Maximum Size
Name
cacheDeviceMaximumSize
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.12
Description
Defines the maximum size of the cache device in
kilobytes (KB). A zero (0) indicates that the size is unknown.
Syntax
DellUnsigned32BitRange
Access
Read-only
Cache Device Current Size
Name
cacheDeviceCurrentSize
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.13
Description
Defines the current size of the cache device in KB. A zero (0)
indicates that the size is unknown.
Syntax
DellUnsigned32BitRange
Access
Read-only
Cache Device Speed
Name
cacheDeviceSpeed
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.14
Description
Defines the speed of the cache device in nanoseconds. A zero (0)
indicates that the speed is unknown.
Syntax
DellUnsigned32BitRange
Access
Read-only
Cache Device Write Policy
Name
cacheDeviceWritePolicy
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.15
Description
Defines the write policy of the cache device.
Syntax
DellCacheDeviceWritePolicy (See Table 13-9)
Access
Read-only
Device Group
283
book.book Page 284 Wednesday, March 6, 2013 12:37 AM
Cache Device Is Socketed
Name
cacheDeviceIsSocketed
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.16
Description
Defines if the cache device is socketed.
Syntax
DellBoolean
Access
Read-only
Cache Device Error Checking and Correction (ECC) Type
Name
cacheDeviceECCType
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.17
Description
Defines the type of error correction in use by the cache device.
Syntax
DellCacheDeviceECCType (See Table 13-11)
Access
Read-only
Cache Device Associativity
Name
cacheDeviceAssociativity
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.18
Description
Defines the type of associativity in use by the cache device.
Syntax
DellCacheDeviceAssociativity (See Table 13-12)
Access
Read-only
Cache Device Supported Type
Name
cacheDeviceSupportedType
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.19
Description
Defines the type of static random-access memory (SRAM) that
the cache device can support.
Syntax
DellCacheDeviceSupportedType
Access
Read-only
284
Device Group
book.book Page 285 Wednesday, March 6, 2013 12:37 AM
Cache Device Current Type
Name
cacheDeviceCurrentType
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.20
Description
Defines the current type of SRAM for the cache device.
Syntax
DellCacheDeviceSRAMType (See Table 13-14)
Access
Read-only
Memory Device Table
Name
memoryDeviceTable
Object ID
1.3.6.1.4.1.674.10892.1.1100.50
Description
Defines the Memory Device Table.
Syntax
SEQUENCE OF MemoryDeviceTableEntry
Access
Not accessible
Memory Device Table Entry
Name
memoryDeviceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1
Description
Defines the Memory Device Table entry.
Syntax
MemoryDeviceTableEntry
Access
Not accessible
Index
memoryDevicechassisIndex, memoryDeviceIndex
Memory Device Chassis Index
Name
memoryDevicechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Device Group
285
book.book Page 286 Wednesday, March 6, 2013 12:37 AM
Memory Device Index
Name
memoryDeviceIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.2
Description
Defines the index of the memory device in this chassis.
Syntax
DellObjectRange
Access
Read-only
Memory Device State Capabilities
Name
memoryDeviceStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.3
Description
Defines the capabilities of the memory device.
Syntax
DellStateCapabilities
Access
Read-only
Memory Device State Settings
Name
memoryDeviceStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.4
Description
Defines the state of the memory device.
Syntax
DellStateSettings
Access
Read-write
Memory Device Status
Name
memoryDeviceStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.5
Description
Defines the status of the memory device.
Syntax
DellStatus
Access
Read-only
286
Device Group
book.book Page 287 Wednesday, March 6, 2013 12:37 AM
Memory Device Memory Port Index Reference
Name
memoryDeviceMemoryPortIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.6
Description
Defines the index of the memory port of which this memory
device is part.
Syntax
DellObjectRange
Access
Read-only
Memory Device Type
Name
memoryDeviceType
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.7
Description
Defines the type of the memory device.
Syntax
DellMemoryDeviceType (See Table 13-16)
Access
Read-only
Memory Device Location Name
Name
memoryDeviceLocationName
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.8
Description
Defines the location name of the memory device.
Syntax
DellString
Access
Read-write
Device Group
287
book.book Page 288 Wednesday, March 6, 2013 12:37 AM
Memory Device Error Count
NOTE: "Memory Device Failure Modes" on page 291 has now replaced this
attribute. Memory Device Error Count should no longer be used. If you use the
Memory Device Error Count attribute, the value returned is always zero, and using
the attribute has no effect.
Name
memoryDeviceErrorCount
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.9
Description
Defines the total number of Error Checking and Correction (ECC)
errors detected by the memory device. Writing a 0 (zero) to this
variable resets the devices error counts.
Syntax
DellSigned32BitRange
Access
Read-write
Memory Device Bank Location Name
Name
memoryDeviceBankLocationName
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.10
Description
Defines the bank location name of the memory device.
Syntax
DellString
Access
Read-only
Memory Device Type Details
Name
memoryDeviceTypeDetails
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.11
Description
Defines the detailed type of the memory device.
Syntax
DellMemoryDeviceTypeDetails (See Table 13-17)
Access
Read-only
288
Device Group
book.book Page 289 Wednesday, March 6, 2013 12:37 AM
Memory Device Form Factor
Name
memoryDeviceFormFactor
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.12
Description
Defines the form factor of the memory device.
Syntax
DellMemoryDeviceFormFactor (See Table 13-15)
Access
Read-only
Memory Device Set
Name
memoryDeviceSet
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.13
Description
Defines if the memory device is a part of a set. A zero (0)
indicates that this device is not part of a set.
Syntax
DellUnsigned32BitRange
Access
Read-only
Memory Device Size
Name
memoryDeviceSize
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.14
Description
Defines the size in KB of the memory device.
Syntax
DellUnsigned32BitRange
Access
Read-only
Memory Device Speed
Name
memoryDeviceSpeed
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.15
Description
Defines the speed in nanoseconds of the memory device.
A zero (0) indicates that the speed is unknown.
Syntax
DellUnsigned32BitRange
Access
Read-only
Device Group
289
book.book Page 290 Wednesday, March 6, 2013 12:37 AM
Memory Device Total Bus Width
Name
memoryDeviceTotalBusWidth
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.16
Description
Defines the total number of bits, including ECC, used by the
memory device.
Syntax
DellUnsigned32BitRange
Access
Read-only
Memory Device Total Data Bus Width
Name
memoryDeviceTotalDataBusWidth
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.17
Description
Defines the total number of data bits used by the memory
device.
Syntax
DellUnsigned32BitRange
Access
Read-only
Memory Device Correctable Memory Event Count
NOTE: "Memory Device Failure Modes" on page 291 has now replaced this
attribute. Memory Device Correctable Memory Event Count should no longer be
used. If you use the Memory Device Correctable Memory Event Count attribute, the
value returned is always zero, and using the attribute has no effect.
Name
memoryDeviceSingleBitErrorCount
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.18
Description
Defines the total number of Correctable Memory Events
detected by the memory device.
Syntax
DellSigned32BitRange
Access
Read-only
290
Device Group
book.book Page 291 Wednesday, March 6, 2013 12:37 AM
Memory Device Uncorrectable Memory Event Count
NOTE: "Memory Device Failure Modes" on page 291 has now replaced this
attribute. Memory Device Uncorrectable Memory Event Count should no longer be
used. If you use the Memory Device Uncorrectable Memory Event Count attribute,
the value returned is always zero, and using the attribute has no effect.
Name
memoryDeviceMultiBitErrorCount
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.19
Description
Defines the total number of Uncorrectable Memory Events
detected by the memory device.
Syntax
DellSigned32BitRange
Access
Read-only
Memory Device Failure Modes
Name
memoryDeviceFailureModes
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.20
Description
Defines the failure modes of the memory device when the
memoryDeviceStatus attribute is not OK. It is a bit field that
can be used to report more than one type of failure mode by
using a combination of the defined bit masks.
Syntax
DellMemoryDeviceFailureModes
Access
Read-only
Memory Device Manufacturer Name
Name
memoryDeviceManufacturerName
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.21
Description
Defines the manufacturer of the memory device.
Syntax
DellString
Access
Read-only
Device Group
291
book.book Page 292 Wednesday, March 6, 2013 12:37 AM
Memory Device Part Number Name
Name
memoryDevicePartNumberName
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.22
Description
Defines the manufacturer's part number for the memory device.
Syntax
DellString
Access
Read-only
Memory Device Serial Number Name
Name
memoryDeviceSerialNumberName
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.23
Description
Defines the serial number of the memory device.
Syntax
DellString
Access
Read-only
Memory Device Asset Tag Name
Name
memoryDeviceAssetTagName
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.24
Description
Defines the asset tag of the memory device.
Syntax
DellString
Access
Read-only
Memory Device Speed Name
Name
memoryDeviceSpeedName
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.25
Description
This attribute defines the speed of the memory device in string
format with units specified in string.
Syntax
DellString
Access
Read-only
292
Device Group
book.book Page 293 Wednesday, March 6, 2013 12:37 AM
Memory Device Mapped Address Table
Name
memoryDeviceMappedAddressTable
Object ID
1.3.6.1.4.1.674.10892.1.1100.60
Description
Defines the Memory Device Mapped Address Table.
Syntax
SEQUENCE OF MemoryDeviceMappedAddressTableEntry
Access
Not accessible
Memory Device Mapped Address Table Entry
Name
memoryDeviceMappedAddressTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1100.60.1
Description
Defines the Memory Device Mapped Address Table entry.
Syntax
MemoryDeviceMappedAddressTableEntry
Access
Not accessible
Index
memoryDeviceMappedAddresschassisIndex,
memoryDeviceMappedAddressIndex
Memory Device Mapped Address Chassis Index
Name
memoryDeviceMappedAddresschassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.60.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Device Group
293
book.book Page 294 Wednesday, March 6, 2013 12:37 AM
Memory Device Mapped Address Index
Name
memoryDeviceMappedAddressIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.60.1.2
Description
Defines the index (one-based) of the memory device mapped
address in this chassis.
Syntax
DellObjectRange
Access
Read-only
Memory Device Mapped Address State Capabilities
Name
memoryDeviceMappedAddressStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1100.60.1.3
Description
Defines the capabilities of the memory device mapped address.
Syntax
DellStateCapabilities
Access
Read-only
Memory Device Mapped Address State Settings
Name
memoryDeviceMappedAddressStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1100.60.1.4
Description
Defines the state of the memory device mapped address.
Syntax
DellStateSettings
Access
Read-write
Memory Device Mapped Address Status
Name
memoryDeviceMappedAddressStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.60.1.5
Description
Defines the status of the memory device mapped address.
Syntax
DellStatus
Access
Read-only
294
Device Group
book.book Page 295 Wednesday, March 6, 2013 12:37 AM
Memory Device Index Reference
Name
memoryDeviceIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1100.60.1.6
Description
Defines the index of the memory device(s) associated with this
memory device mapped address.
Syntax
DellObjectRange
Access
Read-only
Memory Device Mapped Address Row Position
Name
memoryDeviceMappedAddressRowPosition
Object ID
1.3.6.1.4.1.674.10892.1.1100.60.1.7
Description
Defines the position of the referenced memory in a row of the
memory device mapped address.
Syntax
DellUnsigned32BitRange
Access
Read-only
Memory Device Mapped Address Interleave Position
Name
memoryDeviceMappedAddressInterleavePosition
Object ID
1.3.6.1.4.1.674.10892.1.1100.60.1.8
Description
Defines the position of the referenced memory in an interleave
of the memory device mapped address.
Syntax
DellUnsigned32BitRange
Access
Read-only
Device Group
295
book.book Page 296 Wednesday, March 6, 2013 12:37 AM
Memory Device Mapped Address Interleave Depth
Name
memoryDeviceMappedAddressInterleaveDepth
Object ID
1.3.6.1.4.1.674.10892.1.1100.60.1.9
Description
Defines the maximum number of consecutive rows from the
referenced memory device that are accessed in a single
interleaved transfer in the memory device mapped address.
Syntax
DellUnsigned32BitRange
Access
Read-only
Memory Device Mapped Address Starting Address
Name
memoryDeviceMappedAddressStartingAddress
Object ID
1.3.6.1.4.1.674.10892.1.1100.60.1.10
Description
Defines the physical starting address in KB of the memory
device mapped address.
Syntax
DellUnsigned64BitRange
Access
Read-only
Memory Device Mapped Address Ending Address
Name
memoryDeviceMappedAddressEndingAddress
Object ID
1.3.6.1.4.1.674.10892.1.1100.60.1.11
Description
Defines the physical ending address in KB of the memory device
mapped address.
Syntax
DellUnsigned64BitRange
Access
Read-only
Generic Device Table
Name
genericDeviceTable
Object ID
1.3.6.1.4.1.674.10892.1.1100.70
Description
Defines the Generic Device Table.
Syntax
SEQUENCE OF GenericDeviceTableEntry
Access
Not accessible
296
Device Group
book.book Page 297 Wednesday, March 6, 2013 12:37 AM
Generic Device Table Entry
Name
genericDeviceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1100.70.1
Description
Defines the Generic Device Table entry.
Syntax
GenericDeviceTableEntry
Access
Not accessible
Index
genericDevicechassisIndex, genericDeviceIndex
Generic Device Chassis Index
Name
genericDevicechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.70.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Generic Device Index
Name
genericDeviceIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.70.1.2
Description
Defines the index of the generic device in this chassis.
Syntax
DellObjectRange
Access
Read-only
Generic Device State Capabilities
Name
genericDeviceStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1100.70.1.3
Description
Defines the capabilities of the generic device.
Syntax
DellStateCapabilities
Access
Read-only
Device Group
297
book.book Page 298 Wednesday, March 6, 2013 12:37 AM
Generic Device State Settings
Name
genericDeviceStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1100.70.1.4
Description
Defines the state of the generic device.
Syntax
DellStateSettings
Access
Read-write
Generic Device Status
Name
genericDeviceStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.70.1.5
Description
Defines the status of the generic device.
Syntax
DellStatus
Access
Read-only
Generic Device System Slot Index Reference
Name
genericDeviceSystemSlotIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1100.70.1.6
Description
Defines the index of the system slot into which this generic
device is plugged.
Syntax
DellObjectRange
Access
Read-only
Generic Device Type
Name
genericDeviceType
Object ID
1.3.6.1.4.1.674.10892.1.1100.70.1.7
Description
Defines the type of the generic device.
Syntax
DellGenericDeviceType (See Table 13-18)
Access
Read-only
298
Device Group
book.book Page 299 Wednesday, March 6, 2013 12:37 AM
Generic Device Name
Name
genericDeviceName
Object ID
1.3.6.1.4.1.674.10892.1.1100.70.1.8
Description
Defines the name of the generic device.
Syntax
DellString
Access
Read-only
PCI Device Table
Name
pCIDeviceTable
Object ID
1.3.6.1.4.1.674.10892.1.1100.80
Description
Defines the PCI Device Detail Table.
Syntax
SEQUENCE OF PCIDeviceTableEntry
Access
Not accessible
PCI Device Table Entry
Name
pCIDeviceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1100.80.1
Description
Defines the PCI Device Table entry.
Syntax
Not accessible
Access
PCIDeviceTableEntry
Index
pCIDevicechassisIndex, pCIDeviceIndex
PCI Device Chassis Index
Name
pCIDevicechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.80.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
Read-only
Access
DellObjectRange
Device Group
299
book.book Page 300 Wednesday, March 6, 2013 12:37 AM
PCI Device Index
Name
pCIDeviceIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.80.1.2
Description
Defines the index (one-based) of the PCI device in this chassis.
Syntax
DellObjectRange
Access
Read-only
PCI Device State Capabilities
Name
pCIDeviceStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1100.80.1.3
Description
Defines the capabilities of the PCI device.
Syntax
DellStateCapabilities
Access
Read-only
PCI Device State Settings
Name
pCIDeviceStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1100.80.1.4
Description
Defines the state of the PCI device.
Syntax
DellStateSettings
Access
Read-write
PCI Device Status
Name
pCIDeviceStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.80.1.5
Description
Defines the status of the PCI device.
Syntax
DellStatus
Access
Read-only
300
Device Group
book.book Page 301 Wednesday, March 6, 2013 12:37 AM
PCI Device System Slot Index Reference
Name
pCIDeviceSystemSlotIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1100.80.1.6
Description
Defines the index number of the system slot that this PCI
device is in.
Syntax
DellObjectRange
Access
Read-only
PCI Device Data Bus Width
Name
pCIDeviceDataBusWidth
Object ID
1.3.6.1.4.1.674.10892.1.1100.80.1.7
Description
Defines the bus width of the PCI device in this chassis.
Syntax
DellUnsigned32BitRange
Access
Read-only
PCI Device Manufacturer Name
Name
pCIDeviceManufacturerName
Object ID
1.3.6.1.4.1.674.10892.1.1100.80.1.8
Description
Defines the name of the PCI device manufacturer.
Syntax
DellString
Access
Read-only
PCI Device Description Name
Name
pCIDeviceDescriptionName
Object ID
1.3.6.1.4.1.674.10892.1.1100.80.1.9
Description
Defines the descriptive name of the PCI device.
Syntax
DellString
Access
Read-only
Device Group
301
book.book Page 302 Wednesday, March 6, 2013 12:37 AM
PCI Device Speed
Name
pCIDeviceSpeed
Object ID
1.3.6.1.4.1.674.10892.1.1100.80.1.10
Description
Defines the bus speed in MHz of the PCI device in this chassis.
A zero (0) indicates that the speed is unknown.
Syntax
DellUnsigned32BitRange
Access
Read-only
PCI Device Adapter Fault
Name
pCIDeviceAdapterFault
Object ID
1.3.6.1.4.1.674.10892.1.1100.80.1.11
Description
Defines whether the PCI device in this chassis has detected a fault.
Syntax
DellBoolean
Access
Read-only
PCI Device Configuration Space Table
Name
pCIDeviceConfigurationSpaceTable
Object ID
1.3.6.1.4.1.674.10892.1.1100.82
Description
Defines the PCI Device Configuration Table.
Syntax
SEQUENCE OF PCIDeviceConfigurationSpaceTableEntry
Access
Not accessible
PCI Device Configuration Space Table Entry
Name
pCIDeviceConfigurationSpaceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1100.82.1
Description
Defines the PCI Device Configuration Table entry.
Syntax
PCIDeviceConfigurationSpaceTableEntry
Access
Not accessible
Index
pCIDeviceConfigurationSpacechassisIndex,
pCIDeviceConfigurationSpaceIndex
302
Device Group
book.book Page 303 Wednesday, March 6, 2013 12:37 AM
PCI Device Configuration Space Chassis Index
Name
pCIDeviceConfigurationSpacechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.82.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
PCI Device Configuration Space Index
Name
pCIDeviceConfigurationSpaceIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.82.1.2
Description
Defines the index (one-based) of the PCI device configuration
in this chassis.
Syntax
DellObjectRange
Access
Read-only
PCI Device Configuration Space State Capabilities
Name
pCIDeviceConfigurationSpaceStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1100.82.1.3
Description
Defines the capabilities of the PCI device configuration.
Syntax
DellStateCapabilities
Access
Read-only
PCI Device Configuration Space State Settings
Name
pCIDeviceConfigurationSpaceStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1100.82.1.4
Description
Defines the state of the PCI device configuration.
Syntax
DellStateSettings
Access
Read-write
Device Group
303
book.book Page 304 Wednesday, March 6, 2013 12:37 AM
PCI Device Configuration Space Status
Name
pCIDeviceConfigurationSpaceStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.82.1.5
Description
Defines the status of the PCI device configuration.
Syntax
DellStatus
Access
Read-only
PCI Device Index Reference
Name
pCIDeviceIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1100.82.1.6
Description
Defines the index number of PCI device that this configuration
applies to.
Syntax
DellObjectRange
Access
Read-only
PCI Device Configuration Space Bus Number
Name
pCIDeviceConfigurationSpaceBusNumber
Object ID
1.3.6.1.4.1.674.10892.1.1100.82.1.7
Description
Defines the bus number of the PCI device configuration in this
chassis.
Syntax
DellUnsigned32BitRange
Access
Read-only
PCI Device Configuration Space Device Number
Name
pCIDeviceConfigurationSpaceDeviceNumber
Object ID
1.3.6.1.4.1.674.10892.1.1100.82.1.8
Description
Defines the device number of the PCI device in this chassis.
Syntax
DellUnsigned32BitRange
Access
Read-only
304
Device Group
book.book Page 305 Wednesday, March 6, 2013 12:37 AM
PCI Device Configuration Space Function Number
Name
pCIDeviceConfigurationSpaceFunctionNumber
Object ID
1.3.6.1.4.1.674.10892.1.1100.82.1.9
Description
Defines the function number of the PCI device in this chassis.
Syntax
DellUnsigned32BitRange
Access
Read-only
PCI Device Configuration Space Header
Name
pCIDeviceConfigurationSpaceHeader
Object ID
1.3.6.1.4.1.674.10892.1.1100.82.1.10
Description
Defines the common configuration space header of the PCI device.
Syntax
Octet String (SIZE(0..1025))
Access
Read-only
Network Device Table
Name
networkDeviceTable
Object ID
1.3.6.1.4.1.674.10892.1.1100.90
Description
Defines the Network Device Table.
Syntax
SEQUENCE OF NetworkDeviceTableEntry
Access
Not accessible
Network Device Table Entry
Name
networkDeviceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1
Description
Defines the Network Device Table Entry.
Syntax
NetworkDeviceTableEntry
Access
Not accessible
Index
networkDeviceChassisIndex, networkDeviceIndex
Device Group
305
book.book Page 306 Wednesday, March 6, 2013 12:37 AM
Network Device Chassis Index
Name
networkDeviceChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.1
Description
Defines the index (one-based) of the chassis that contains the
network device.
Syntax
DellObjectRange
Access
Read-only
Network Device Index
Name
networkDeviceIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.2
Description
Defines the index (one-based) of the network device.
Syntax
DellObjectRange
Access
Read-only
Network Device Status
Name
networkDeviceStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.3
Description
Defines the status of the network device.
Syntax
DellStatus
Access
Read-only
Network Device Connection Status
Name
networkDeviceConnectionStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.4
Description
Defines the connection status of the network device.
Syntax
DellNetworkDeviceConnectionStatus (see Table 13-20)
Access
Read-only
306
Device Group
book.book Page 307 Wednesday, March 6, 2013 12:37 AM
Network Device Description Name
Name
networkDeviceDescriptionName
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.5
Description
Defines the description of the network device.
Syntax
DellString
Access
Read-only
Network Device Product Name
Name
networkDeviceProductName
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.6
Description
Defines the product name of the network device.
Syntax
DellString
Access
Read-only
Network Device Vendor Name
Name
networkDeviceVendorName
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.7
Description
Defines the name of the vendor of the network device.
Syntax
DellString
Access
Read-only
Network Device Service Name
Name
networkDeviceServiceName
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.8
Description
Defines the service name of the network device.
Syntax
DellString
Access
Read-only
Device Group
307
book.book Page 308 Wednesday, March 6, 2013 12:37 AM
Network Device Driver Image Path Name
Name
networkDeviceDriverImagePathName
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.9
Description
Defines the path to the binary image of the driver for the
network device.
Syntax
DellString
Access
Read-only
Network Device Driver Version Name
Name
networkDeviceDriverVersionName
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.10
Description
Defines the version of the driver for the network device.
Syntax
DellString
Access
Read-only
Network Device IP Address
Name
networkDeviceIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.11
Description
Defines the IP address of the network device.
Syntax
IpAddress
Access
Read-only
Network Device IP Subnet Mask
Name
networkDeviceIPSubnetMask
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.12
Description
Defines the IP subnet mask for the IP address currently assigned
to the network device.
Syntax
IpAddress
Access
Read-only
308
Device Group
book.book Page 309 Wednesday, March 6, 2013 12:37 AM
Network Device Default Gateway IP Address
Name
networkDeviceDefaultGatewayIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.13
Description
Defines the IP address of the default gateway for the network device.
Syntax
IpAddress
Access
Read-only
Network Device DHCP Server IP Address
Name
networkDeviceDHCPServerIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.14
Description
Defines the IP address of the DHCP server that was used to
obtain the IP address of the network device if DHCP was used
to configure the network device.
Syntax
IpAddress
Access
Read-only
Network Device Current MAC Address
Name
networkDeviceCurrentMACAddress
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.15
Description
Defines the current MAC address of the network device.
Syntax
DellMACAddress
Access
Read-only
Network Device Permanent MAC Address
Name
networkDevicePermanentMACAddress
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.16
Description
Defines the permanent MAC address of the network device.
Syntax
DellMACAddress
Access
Read-only
Device Group
309
book.book Page 310 Wednesday, March 6, 2013 12:37 AM
Network Device PCI Bus Number
Name
networkDevicePCIBusNumber
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.17
Description
Defines the PCI bus number of the network device.
Syntax
DellUnsigned8BitRange
Access
Read-only
Network Device PCI Device Number
Name
networkDevicePCIDeviceNumber
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.18
Description
Defines the PCI device number of the network device.
Syntax
DellUnsigned8BitRange
Access
Read-only
Network Device PCI Function Number
Name
networkDevicePCIFunctionNumber
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.19
Description
Defines the PCI function number of the network device.
Syntax
DellUnsigned8BitRange
Access
Read-only
Network Device IRQ
Name
networkDeviceIRQ
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.20
Description
Defines the interrupt request number of the network device.
Syntax
DellUnsigned32BitRange
Access
Read-only
310
Device Group
book.book Page 311 Wednesday, March 6, 2013 12:37 AM
Network Device Base IO Port Address
Name
networkDeviceBaseIOPortAddress
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.21
Description
Defines the base input/outport port address of the network device.
Syntax
DellUnsigned32BitRange
Access
Read-only
Network Device Teaming Flags
Name
networkDeviceTeamingFlags
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.22
Description
Defines the teaming features of the network device.
Syntax
DellNetworkDeviceTeamingFlags (see Table 13-21)
Access
Read-only
Network Device TOE Capability Flags
Name
networkDeviceTOECapabilityFlags
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.23
Description
Defines the TCP/IP Offload Engine (TOE) capability flags of
the network device.
Syntax
DellNetworkDeviceTOECapabilityFlags (see Table 13-22)
Access
Read-only
Network Device TOE Enabled
Name
networkDeviceTOEEnabled
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.24
Description
Defines if TOE is enabled for the network device.
Syntax
DellBoolean
Access
Read-only
Device Group
311
book.book Page 312 Wednesday, March 6, 2013 12:37 AM
Network Device RDMA Capability Flags
Name
networkDeviceRDMACapabilityFlags
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.25
Description
Defines the Remote Direct Memory Access (RDMA) capability
flags of the network device.
Syntax
DellNetworkDeviceRDMACapabilityFlags (see Table 13-23)
Access
Read-only
Network Device RDMA Enabled
Name
networkDeviceRDMAEnabled
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.26
Description
Defines if RDMA is enabled for the network device.
Syntax
DellBoolean
Access
Read-only
Network Device iSCSI Capability Flags
Name
networkDeviceiSCSICapabilityFlags
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.27
Description
Defines the Internet Small Computer System Interface (iSCSI)
capability flags of the network device.
Syntax
DellNetworkDeviceiSCSICapabilityFlags (see Table 13-24)
Access
Read-only
Network Device iSCSI Enabled
Name
networkDeviceiSCSIEnabled
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.28
Description
Defines if iSCSI is enabled for the network device.
Syntax
DellBoolean
Access
Read-only
312
Device Group
book.book Page 313 Wednesday, March 6, 2013 12:37 AM
Managed System Services Device Table
Name
managedSystemServicesDeviceTable
Object ID
1.3.6.1.4.1.674.10892.1.1100.100
Description
Defines the Managed System Services Device Table.
Syntax
Sequence of ManagedSystemServicesDeviceTable
Access
Not accessible
Managed System Services Device Table Entry
Name
managedSystemServicesDeviceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1100.100.1
Description
Defines the managed system services device table entry.
Syntax
ManagedSystemServicesDeviceTableEntry
Access
Not accessible
Index
managedSystemServicesDeviceChassisIndex,
managedSystemServicesDeviceIndex
Managed System Services Device Chassis Index
Name
managedSystemServicesDeviceChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.100.1.1
Description
Defines the index (one-based) of the chassis that contains the
managed system services device.
Syntax
DellObjectRange
Access
Read-only
Device Group
313
book.book Page 314 Wednesday, March 6, 2013 12:37 AM
Managed System Services Device Index
Name
managedSystemServicesDeviceIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.100.1.2
Description
Defines the index (one-based) of the managed system services
device.
Syntax
DellObjectRange
Access
Read-only
Managed System Services Device Status
Name
managedSystemServicesDeviceStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.100.1.3
Description
Defines the status of the managed system services device.
Syntax
DellStatus
Access
Read-only
Managed System Services Device Type
Name
managedSystemServicesDeviceType
Object ID
1.3.6.1.4.1.674.10892.1.1100.100.1.4
Description
Defines the type of the managed system services device.
Syntax
DellManagedSystemServicesDeviceType. See Table 13-25
Access
Read-only
314
Device Group
book.book Page 315 Wednesday, March 6, 2013 12:37 AM
Managed System Services Device Storage Present
Name
managedSystemServicesDeviceStoragePresent
Object ID
1.3.6.1.4.1.674.10892.1.1100.100.1.5
Description
Defines whether storage is present on the managed system
services device.
Syntax
DellBoolean
Access
Read-only
Managed System Services Device Storage Size
Name
managedSystemServicesDeviceStorageSize
Object ID
1.3.6.1.4.1.674.10892.1.1100.100.1.6
Description
Defines the size in Megabytes (MB) of the storage present on
the managed system services device.
Syntax
DellUnsigned32BitRange
Access
Read-only
SD Card Unit Table
Name
sdCardUnitTable
Object ID
1.3.6.1.4.1.674.10892.1.1100.110
Description
Defines the SD Card Unit Table.
Syntax
SEQUENCE OF SdCardUnitTableEntry
Access
Not accessible
SD Card Unit Table Entry
Name
sdCardUnitTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1100.110.1
Description
Defines the SD Card Unit Table Entry.
Syntax
SdCardUnitTableEntry
Access
Not accessible
Device Group
315
book.book Page 316 Wednesday, March 6, 2013 12:37 AM
Name
sdCardUnitTableEntry
Index
sdCardUnitChassisIndex,
sdCardUnitIndex
SD Card Unit Chassis Index
Name
sdCardUnitChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.110.1.1
Description
Defines the index (one-based) of the chassis that contains the
SD Card unit.
Syntax
DellObjectRange
Access
Read-only
SD Card Unit Index
Name
sdCardUnitIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.110.1.2
Description
Defines the index (one-based) of the SD Card unit.
Syntax
DellObjectRange
Access
Read-only
SD Card Unit State Capabilities
Name
sdCardUnitStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1100.110.1.3
Description
Defines the state capabilities of the SD Card unit.
Syntax
DellStateCapabilities
Access
Read-only
SD Card Unit State Settings
Name
sdCardUnitStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1100.110.1.4
316
Device Group
book.book Page 317 Wednesday, March 6, 2013 12:37 AM
Name
sdCardUnitStateSettings
Description
Defines the state settings of the SD Card unit.
Syntax
DellStateSettings
Access
Read-only
SD Card Unit Redundancy Status
Name
sdCardUnitRedundancyStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.110.1.5
Description
Defines the redundancy status of the SD Card unit.
Syntax
DellStatusRedundancy
Access
Read-only
SD Card Unit Count For Redundancy
Name
sdCardUnitCountForRedundancy
Object ID
1.3.6.1.4.1.674.10892.1.1100.110.1.6
Description
Defines the total number of SD Card devices required for this
SD Card unit to have full redundancy.
Syntax
DellObjectRange
Access
Read-only
SD Card Unit Name
Name
sdCardUnitName
Object ID
1.3.6.1.4.1.674.10892.1.1100.110.1.7
Description
Defines the name of the SD Card unit.
Syntax
DellString
Access
Read-only
Device Group
317
book.book Page 318 Wednesday, March 6, 2013 12:37 AM
SD Card Unit Status
Name
sdCardUnitStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.110.1.8
Description
Defines the status of the SD Card unit.
Syntax
DellStatus
Access
Read-only
SD Card Device Table
Name
sdCardDeviceTable
Object ID
1.3.6.1.4.1.674.10892.1.1100.112
Description
Defines the SD Card Device Table.
Syntax
SEQUENCE OF SdCardDeviceTableEntry
Access
Not accessible
SD Card Device Table Entry
Name
sdCardDeviceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1100.112.1
Description
Defines the SD Card Device Table Entry.
Syntax
SdCardDeviceTableEntry
Access
Not accessible
Index
sdCardDeviceChassisIndex,
sdCardDeviceIndex
SD Card Device Chassis Index
Name
sdCardDeviceChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.112.1.1
Description
Defines the index (one-based) of the chassis that contains the
SD Card device.
Syntax
DellObjectRange
318
Device Group
book.book Page 319 Wednesday, March 6, 2013 12:37 AM
Name
sdCardDeviceChassisIndex
Access
Read-only
SD Card Device Index
Name
sdCardDeviceIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.112.1.2
Description
Defines the index (one-based) of the SD Card device.
Syntax
DellObjectRange
Access
Read-only
SD Card Device Status
Name
sdCardDeviceStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.112.1.3
Description
Defines the status of the SD Card device.
Syntax
DellStatus
Access
Read-only
SD Card Device Type
Name
sdCardDeviceType
Object ID
1.3.6.1.4.1.674.10892.1.1100.112.1.4
Description
Defines the type of the SD Card device.
Syntax
DellSDCardDeviceType
Access
Read-only
SD Card Device Config Capabilities
Name
sdCardDeviceConfigCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1100.112.1.5
Description
Defines the configuration capabilities of the SD Card device.
Syntax
DellSDCardDeviceConfigCapabilities
Device Group
319
book.book Page 320 Wednesday, March 6, 2013 12:37 AM
Name
sdCardDeviceConfigCapabilities
Access
Read-only
SD Card Device Config Settings
Name
sdCardDeviceConfigSettings
Object ID
1.3.6.1.4.1.674.10892.1.1100.112.1.6
Description
Defines the configuration settings of the SD Card device.
Syntax
DellSDCardDeviceConfigSettings
Access
Read-only
SD Card Device Location Name
Name
sdCardDeviceLocationName
Object ID
1.3.6.1.4.1.674.10892.1.1100.112.1.7
Description
Defines the location of the SD Card device.
Syntax
DellString
Access
Read-only
SD Card Device Card Present
Name
sdCardDeviceCardPresent
Object ID
1.3.6.1.4.1.674.10892.1.1100.112.1.8
Description
Defines whether the SD Card is present for the SD Card device.
Syntax
DellBoolean
Access
Read-only
SD Card Device Card State
Name
sdCardDeviceCardState
Object ID
1.3.6.1.4.1.674.10892.1.1100.112.1.9
Description
Defines the state of the SD Card.
Syntax
DellSDCardDeviceCardState
320
Device Group
book.book Page 321 Wednesday, March 6, 2013 12:37 AM
Name
sdCardDeviceCardState
Access
Read-only
SD Card Device Card Storage Size
Name
sdCardDeviceCardStorageSize
Object ID
1.3.6.1.4.1.674.10892.1.1100.112.1.10
Description
Defines the storage size in MB (megabytes) of the SD card for
the SD Card device.
Syntax
DellUnsigned32BitRange
Access
Read-only
SD Card Device Unit Index Reference
Name
sdCardDeviceUnitIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1100.112.1.11
Description
Defines the index to the associated SD Card unit if the SD Card
device is part of a SD Card unit.
Syntax
DellObjectRange
Access
Read-only
Device Group
321
book.book Page 322 Wednesday, March 6, 2013 12:37 AM
SD Card Device Card Available Storage Size
Name
sdCardDeviceCardAvailableStorageSize
Object ID
1.3.6.1.4.1.674.10892.1.1100.112.1.12
Description
Defines the available storage size in MB (megabytes) of the SD
card for the SD card device.
Syntax
DellSigned32BitRange
Access
Read-only
SD Card Device Card Licensed
Name
sdCardDeviceCardLicensed
Object ID
1.3.6.1.4.1.674.10892.1.1100.112.1.13
Description
Defines whether the SD card is licensed by the system vendor.
Syntax
DellSDCardDeviceCardLicensed
Access
Read-only
Device Group Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 13-1. Pointing Device Type
Variable Name: DellPointingDeviceType
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceTypeIsOther(1)
Device type is not one of the following:
deviceTypeIsUnknown(2)
Device type is unknown.
deviceTypeIsAMouse(3)
Device type is a mouse.
deviceTypeIsATrackBall(4)
Device type is a track ball.
deviceTypeIsATrackPoint(5)
Device type is a track point.
deviceTypeIsAGlidePoint(6)
Device type is a glide point.
322
Device Group
book.book Page 323 Wednesday, March 6, 2013 12:37 AM
Table 13-1.
Pointing Device Type (continued)
Variable Name: DellPointingDeviceType
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceTypeIsATouchPad(7)
Device type is a touch pad.
Table 13-2.
Processor Device Status State
Variable Name: DellProcessorDeviceStatusState
Data Type: Integer
Possible Data Values
Meaning of Data Value
other(1)
Processor device type is not one of the
following:
unknown(2)
Device type is unknown.
enabled(3)
Device is enabled.
userDisabled(4)
Device is disabled by the user.
biosDisabled(5)
Device has its BIOS disabled.
idle(6)
Device is idle.
Table 13-3.
Processor Device Status Reading
Variable Name: DellProcessorDeviceStatusReading
Data Type: Integer
NOTE: These values are bit masks, so combination values are possible.
Possible Data Values
Meaning of Data Value
internalError(1)
The processor experienced an internal
error
thermalTrip(2)
The processor experienced a thermal trip
configurationError(32)
The processor experienced a configuration
error
processorPresent(128)
The processor is present
Device Group
323
book.book Page 324 Wednesday, March 6, 2013 12:37 AM
Table 13-3. Processor Device Status Reading (continued)
Variable Name: DellProcessorDeviceStatusReading
Data Type: Integer
NOTE: These values are bit masks, so combination values are possible.
Possible Data Values
Meaning of Data Value
processorDisabled(256)
The processor is disabled
terminatorPresent(512)
The terminator is Present
processorThrottled(1024)
The processor is throttled
Table 13-4. Processor Device Type
Variable Name: DellProcessorDeviceType
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceTypeIsOther(1)
The processor device type is not one
of the following values:
deviceTypeIsUnknown(2)
The processor device type is
unknown.
deviceTypeIsCPU(3)
The processor device type is a central
processing unit.
deviceTypeIsMathProcessor(4)
The processor device type is a math
processor.
deviceTypeIsDSP(5)
The processor device type is a digital
signal processor.
deviceTypeIsAVideoProcessor(6)
The processor device is a video
processor.
324
Device Group
book.book Page 325 Wednesday, March 6, 2013 12:37 AM
Table 13-5.
Processor Upgrade Information
Variable Name: DellProcessorUpgradeInformation
Data Type: Integer
Possible Data Values
Meaning of Data Value
processorUpgradeIsOther(1)
The upgrade device type is
not one of the following:
processorUpgradeIsUnknown(2)
Upgrade device type is
unknown.
processorUpgradeIsByDaughterBoard(3)
Upgrade device is on a
daughter board.
processorUpgradeIsByZIFSocket(4)
Upgrade device is in a zero
insertion force (ZIF) socket.
processorUpgradeIsByReplacement(5)
Upgrade device is a
replacement.
processorUpgradeIsNone(6)
There is no upgrade device.
processorUpgradeIsByLIFSocket(7)
Upgrade device is in a low
insertion force (LIF) socket.
processorUpgradeIsBySlot1(8)
Upgrade device is a SLOT 1
processor.
processorUpgradeIsBySlot2(9)
Upgrade device is a SLOT 2
processor.
processorUpgradeIsBy370PinSocket(10)
Upgrade device is a 370 pin
socket.
processorUpgradeIsBySlotA(11)
Upgrade is by Slot A.
processorUpgradeIsBySlotM(12)
Upgrade is by Slot M.
processorUpgradeIsByScoket423(13)
Upgrade is by Socket 423.
processorUpgradeIsBySocketA(14)
Upgrade is by Socket A
(Socket 462).
processorUpgradeIsBySocket478(15)
Upgrade is by Socket 478.
processorUpgradeIsBySocket754(16)
Upgrade is by Socket 754.
processorUpgradeIsBySocket940(17)
Upgrade is by Socket 940.
Device Group
325
book.book Page 326 Wednesday, March 6, 2013 12:37 AM
Table 13-5. Processor Upgrade Information (continued)
Variable Name: DellProcessorUpgradeInformation
Data Type: Integer
Possible Data Values
Meaning of Data Value
processorUpgradeIsBySocket939(18)
Upgrade is by Socket 939.
processorUpgradeIsBySocketmPGA604(19) Upgrade is by Socket
mPGA604.
processorUpgradeIsBySocketLGA771(20)
Upgrade is by Socket
LGA771.
processorUpgradeIsBySocketLGA775(21)
Upgrade is by Socket
LGA775.
processorUpgradeIsBySocketS1(22)
Upgrade is by Socket S1.
processorUpgradeIsBySocketAM2(23)
Upgrade is by Socket AM2.
processorUpgradeIsBySocketF(24)
Upgrade is by Socket F
(1207).
processorUpgradeIsBySocketLGA1366(25) Upgrade is by Socket
LGA1366.
Table 13-6. Processor Device Family
Variable Name: DellProcessorDeviceFamily
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceFamilyIsOther(1)
The processor family is not one of the
following values.
deviceFamilyIsUnknown(2)
The processor family is unknown.
deviceFamilyIs8086(3)
The processor family is 8086.
deviceFamilyIs80286(4)
The processor family is 80286.
deviceFamilyIs80386(5)
The processor family is 80386.
deviceFamilyIs80486(6)
The processor family is 80486.
deviceFamilyIS8087(7)
The processor family is 8087.
326
Device Group
book.book Page 327 Wednesday, March 6, 2013 12:37 AM
Table 13-6.
Processor Device Family (continued)
Variable Name: DellProcessorDeviceFamily
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceFamilyIs80287(8)
The processor family is 80287.
deviceFamilyIs80387(9)
The processor family is 80387.
deviceFamilyIs80487(10)
The processor family is 80487.
deviceFamilyIsPentium(11)
The processor family is Intel Pentium.
deviceFamilyIsPentiumPro(12)
The processor family is Pentium Pro.
deviceFamilyIsPentium2(13)
The processor family is Pentium II.
deviceFamilyIsPentiumMMX(14)
The processor family is Pentium MMX.
deviceFamilyIsCeleron(15)
The processor family is Celeron.
deviceFamilyIsXeon(16)
The processor family is Xeon.
deviceFamilyIsPentium3(17)
The processor family is Pentium III.
deviceFamilyIsPentium3Xeon(18) The processor family is Pentium III
Xeon.
deviceFamilyIsPentium3Step(19) The processor family is Pentium III
Speed Step.
deviceFamilyIsPentiumItanium
(20)
The processor family is Itanium.
deviceFamilyIsIntelXeon(21)
The processor family is Intel Xeon.
deviceFamilyIsPentium4(22)
The processor family is Pentium 4.
deviceFamilyIsIntelXeonMP(23)
The processor family is Intel Xeon MP.
deviceFamilyIsIntelItanium2(24) The processor family is Intel Itanium 2.
deviceFamilyIsK5(25)
The processor family is K5.
deviceFamilyIsK6(26)
The processor family is K6.
deviceFamilyIsK6-2(27)
The processor family is K6-2.
deviceFamilyIsK6-3(28)
The processor family is K6-3.
deviceFamilyIsAMDAthlon(29)
The processor family is AMD Athlon.
deviceFamilyIsAMD2900(30)
The processor family is AMD2900.
Device Group
327
book.book Page 328 Wednesday, March 6, 2013 12:37 AM
Table 13-6. Processor Device Family (continued)
Variable Name: DellProcessorDeviceFamily
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceFamilyIsK6-2Plus(31)
The processor family is K6-2+.
deviceFamilyIsPowerPC(32)
The processor family is Power PC.
deviceFamilyIsPowerPC601(33)
The processor family is Power PC 601.
deviceFamilyIsPowerPC603(34)
The processor family is Power PC 603.
deviceFamilyIsPowerPC603Plus
(35)
The processor family is Power PC
603+.
deviceFamilyIsPowerPC604(36)
The processor family is Power PC 604.
deviceFamilyIsPowerPC620(37)
The processor family is Power PC 620.
deviceFamilyIsPowerPCx704(38)
The processor family is Power PC x704.
deviceFamilyIsPowerPC750(39)
The processor family is Power PC 750.
deviceFamilyIsIntelCoreDuo(40) The processor family is Intel Core Duo.
deviceFamilyIsIntelCoreDuoMobi The processor family is Intel Core Duo
le(41)
mobile.
deviceFamilyIsIntelCoreSoloMob The processor family is Intel Core Solo
ile(42)
mobile.
deviceFamilyIsIntelAtom(43)
The processor family is Intel Atom.
deviceFamilyIsAlpha(48)
The processor family is Alpha.
deviceFamilyIsAlpha21064(49)
The processor family is Alpha 21064.
deviceFamilyIsAlpha21066(50)
The processor family is Alpha 21066.
deviceFamilyIsAlpha21164(51)
The processor family is Alpha 21164.
deviceFamilyIsAlpha21164PC(52) The processor family is Alpha
21164PC.
deviceFamilyIsAlpha21164a(53)
The processor family is Alpha 21164a.
deviceFamilyIsAlpha21264(54)
The processor family is Alpha 21264.
deviceFamilyIsAlpha21364(55)
The processor family is Alpha 21364.
328
Device Group
book.book Page 329 Wednesday, March 6, 2013 12:37 AM
Table 13-6.
Processor Device Family (continued)
Variable Name: DellProcessorDeviceFamily
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceFamilyIsAMDTurionIIUltra The processor family is AMD Turion II
DualMobileM(56)
Ultra Dual-Core Mobile M Processor
Family.
deviceFamilyIsAMDTurionIIDualM The processor family is AMD Turion II
obileM(57)
Dual-Core Mobile M Processor Family.
deviceFamilyIsAMDAthlonIIDualM The processor family is AMD Athlon II
obileM(58)
Dual-Core Mobile M Processor Family.
deviceFamilyIsAMDOpteron6100
(59)
The processor family is AMD Opteron
6100 Series Processor.
deviceFamilyIsAMDOpteron4100
(60)
The processor family is AMD Opteron
4100 Series Processor.
deviceFamilyIsAMDOpteron6200
(61)
The processor family is AMD Opteron
6200 Series Processor.
deviceFamilyIsAMDOpteron4200
(62)
The processor family is AMD Opteron
4200 Series Processor.
deviceFamilyIsMIPS(64)
The processor family is MIPS.
deviceFamilyIsMIPSR4000(65)
The processor family is MIPS R4000.
deviceFamilyIsMIPSR4200(66)
The processor family is MIPS R4200.
deviceFamilyIsMIPSR4400(67)
The processor family is MIPS R4400.
deviceFamilyIsMIPSR4600(68)
The processor family is MIPS R4600.
deviceFamilyIsMIPSR10000(69)
The processor family is MIPS R10000.
deviceFamilyIsSPARC(80)
The processor family is SPARC.
deviceFamilyIsSuperSPARC(81)
The processor family is SuperSPARC.
deviceFamilyIsmicroSPARCII(82) The processor family is microSPARC II.
deviceFamilyIsmicroSPARCIIep
(83)
The processor family is microSPARC
IIep.
deviceFamilyIsUltraSPARC(84)
The processor family is UltraSPARC.
deviceFamilyIsUltraSPARCII(85) The processor family is UltraSPARC II.
Device Group
329
book.book Page 330 Wednesday, March 6, 2013 12:37 AM
Table 13-6. Processor Device Family (continued)
Variable Name: DellProcessorDeviceFamily
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceFamilyIsUltraSPARCIIi(86) The processor family is UltraSPARC IIi.
deviceFamilyIsUltraSPARCIII(87) The processor family is UltraSPARC
III.
deviceFamilyIsUltraSPARCIIIi
(88)
The processor family is UltraSPARC
IIIi.
deviceFamilyIs68040(96)
The processor family is 68040 Family.
deviceFamilyIs68xxx(97)
The processor family is 68xxx.
deviceFamilyIs68000(98)
The processor family is 68000.
deviceFamilyIs68010(99)
The processor family is 68010.
deviceFamilyIs68020(100)
The processor family is 68020.
deviceFamilyIs68030(101)
The processor family is 68030.
deviceFamilyIsHobbit(112)
The processor family is Hobbit.
deviceFamilyIsCrusoe5000(120)
The processor family is Crusoe 5000.
deviceFamilyIsCrusoe3000(121)
The processor family is Crusoe 3000.
deviceFamilyIsEfficeon8000
(122)
The processor family is Efficeon 8000.
deviceFamilyIsWeitek(128)
The processor family is Weitek.
deviceFamilyIsIntelCeleronM(13 The processor family is Intel Celeron
0)
M.
deviceFamilyIsAMDAthlon64(131) The processor family is AMD Athlon
64.
deviceFamilyIsAMDOpteron(132)
The processor family is AMD Opteron.
deviceFamilyIsAMDSempron(133)
The processor family is AMD Sempron.
deviceFamilyIsAMDTurion64Mobile The processor family is AMD Turion 64
(134)
Mobile Technology.
deviceFamilyIsDualCoreAMDOpter The processor family is Dual-Core
on(135)
AMD Opteron.
330
Device Group
book.book Page 331 Wednesday, March 6, 2013 12:37 AM
Table 13-6.
Processor Device Family (continued)
Variable Name: DellProcessorDeviceFamily
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceFamilyIsAMDAthlon64X2Dual The processor family is AMD Athlon
Core(136)
64 X2 Dual-Core.
deviceFamilyIsAMDTurion64X2Mob The processor family is AMD Turion 64
ile(137)
X2 Mobile Technology.
deviceFamilyIsQuadCoreAMDOpter The processor family is Quad-Core
on(138)
AMD Opteron.
deviceFamilyIsThirdGeneration
AMDOpteron(139)
The processor family is thirdgeneration AMD Opteron.
deviceFamilyIsAMDPhenomFXQuadC The processor family is AMD Phenom
ore(140)
FX Quad-Core.
deviceFamilyIsAMDPhenomX4QuadC The processor family is AMD Phenom
ore(141)
X4 Quad-Core.
deviceFamilyIsAMDPhenomX2DualC The processor family is AMD Phenom
ore(142)
X2 Dual-Core.
deviceFamilyIsAMDAthlonX2DualC The processor family is AMD Athlon
ore(143)
X2 Dual-Core.
deviceFamilyIsPA-RISC(144)
The processor family is PA-RISC.
deviceFamilyIsPA-RISC8500(145) The processor family is PA-RISC 8500.
deviceFamilyIsPA-RISC8000(146) The processor family is PA-RISC 8000.
deviceFamilyIsPARISC7300LC(147)
The processor family is PA-RISC
7300LC.
deviceFamilyIsPA-RISC7200(148) The processor family is PA-RISC 7200.
deviceFamilyIsPARISC7100LC(149)
The processor family is PA-RISC
7100LC.
deviceFamilyIsPA-RISC7100(150) The processor family is PA-RISC 7100.
deviceFamilyIsV30(160)
The processor family is V30.
deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core
n3200(161)
Intel Xeon processor 3200 Series.
Device Group
331
book.book Page 332 Wednesday, March 6, 2013 12:37 AM
Table 13-6. Processor Device Family (continued)
Variable Name: DellProcessorDeviceFamily
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
n3000(162)
Xeon processor 3000 Series.
deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core
n5300(163)
Intel Xeon processor 5300 Series.
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
n5100(164)
Xeon processor 5100 Series.
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
n5000(165)
Xeon processor 5000 Series.
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
nLV(166)
Xeon processor LV.
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
nULV(167)
Xeon processor ULV.
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
n7100(168)
Xeon processor 7100 Series.
deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core
n5400(169)
Intel Xeon processor 5400 Series.
deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core
n(170)
Intel Xeon.
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
n5200(171)
Xeon processor 5200 Series.
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
n7200(172)
Xeon processor 7200 Series.
deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core
n7300(173)
Intel Xeon processor 7300 Series.
deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core
n7400(174)
Intel Xeon processor 7400 Series.
deviceFamilyIsMultiCoreIntelXe The processor family is Multi-Core
on7400(175)
Intel Xeon processor 7400 Series.
deviceFamilyIsM1(176)
332
Device Group
The processor family is M1.
book.book Page 333 Wednesday, March 6, 2013 12:37 AM
Table 13-6.
Processor Device Family (continued)
Variable Name: DellProcessorDeviceFamily
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceFamilyIsM2(177)
The processor family is M2.
deviceFamilyIsIntelPentium4HT
(179)
The processor family is Intel Pentium 4
HT processor.
deviceFamilyIsAS400(180)
The processor family is AS400.
deviceFamilyIsAMDAthlonXP(182) The processor family is AMD Athlon
XP.
deviceFamilyIsAMDAthlonMP(183) The processor family is AMD Athlon
MP.
deviceFamilyIsAMDDuron(184)
The processor family is AMD Duron.
deviceFamilyIsIntelPentiumM(185) The processor family is Intel Pentium M.
deviceFamilyIsIntelCeleronD(186) The processor family is Intel Celeron
D.
deviceFamilyIsIntelPentiumD(187) The processor family is Intel Pentium
D.
deviceFamilyIsIntelPentiumExtr The processor family is Intel Pentium
eme(188)
Processor Extreme Edition.
deviceFamilyIsIntelCoreSolo
(189)
The processor family is Intel Core Solo
processor.
deviceFamilyIsIntelCore2(190)
The processor family is Intel Core 2
processor.
deviceFamilyIsIntelCore2Duo
(191)
The processor family is Intel Core 2
Duo processor.
deviceFamilyIsIntelCore2Solo
(192)
The processor family is Intel Core2
Solo processor.
deviceFamilyIsIntelCore2Extrem The processor family is Intel Core2
e(193)
Extreme processor.
deviceFamilyIsIntelCore2Quad
(194)
The processor family is Intel Core2
Quad processor.
Device Group
333
book.book Page 334 Wednesday, March 6, 2013 12:37 AM
Table 13-6. Processor Device Family (continued)
Variable Name: DellProcessorDeviceFamily
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceFamilyIsIntelCore2Extrem The processor family is Intel Core2
eMobile(195)
Extreme mobile processor.
deviceFamilyIsIntelCore2DuoMob The processor family is Intel Core2
ile(196)
Duo mobile processor.
deviceFamilyIsIntelCore2SoloMo The processor family is Intel Core2
bile(197)
Solo mobile processor.
deviceFamilyIsIntelCorei7(198) The processor family is Intel Core i7
processor.
deviceFamilyIsDualCoreIntelCel The processor family is Dual-Core Intel
eron(199)
Celeron Processor.
deviceFamilyIsIBM390(200)
The processor family is IBM390.
deviceFamilyIsG4(201)
The processor family is G4.
deviceFamilyIsG5(202)
The processor family is G5.
deviceFamilyIsESA390G6(203)
The processor family is ESA/390 G6.
deviceFamilyIszArchitectur
(204)
The processor family is z/Architectur
base.
deviceFamilyIsIntelCorei5(205) The processor family is Intel Core i5
processor.
deviceFamilyIsIntelCorei3(206) The processor family is Intel Core i3
processor.
deviceFamilyIsVIAC7-M(210)
The processor family is VIA C7-M.
deviceFamilyIsVIAC7-D(211)
The processor family is family is VIA
C7-D.
deviceFamilyIsVIAC7(212)
The processor family is VIA C7.
deviceFamilyIsVIAEden(213)
The processor family is VIA Eden.
deviceFamilyIsMultiCoreIntelXe The processor family is Multi-Core
on(214)
Intel Xeon processor.
334
Device Group
book.book Page 335 Wednesday, March 6, 2013 12:37 AM
Table 13-6.
Processor Device Family (continued)
Variable Name: DellProcessorDeviceFamily
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
n3xxx(215)
Xeon processor 3xxx Series.
deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core
n3xxx(216)
Intel Xeon processor 3xxx Series.
deviceFamilyIsVIANano(217)
The processor family is VIA Nano.
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
n5xxx(218)
Xeon processor 5xxx Series.
deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core
n5xxx(219)
Intel Xeon processor 5xxx Series.
deviceFamilyIsDualCoreIntelXeo The processor family is Dual-Core Intel
n7xxx(221)
Xeon processor 7xxx Series.
deviceFamilyIsQuadCoreIntelXeo The processor family is Quad-Core
n7xxx(222)
Intel Xeon processor 7xxx Series.
deviceFamilyIsMultiCoreIntelXe The processor family is Multi-Core
on7xxx(223)
Intel Xeon processor 7xxx Series.
deviceFamilyIsMultiCoreIntelXe The processor family is Multi-Core
on3400(224)
Intel Xeon processor 3400 Series.
deviceFamilyIsEmbeddedAMDOpert The processor family is Embedded
onQuadCore(230)
AMD Opteron Quad-Core.
deviceFamilyIsAMDPhenomTripleC The processor family is AMD Phenom
ore(231)
Triple-Core.
deviceFamilyIsAMDTurionUltraDu The processor family is AMD Turion
alCoreMobile(232)
Ultra Dual-Core mobile processor.
deviceFamilyIsAMDTurionDualCor The processor family is AMD Turion
eMobile(233)
Dual-Core mobile processor.
deviceFamilyIsAMDAthlonDualCor The processor family is AMD Athlon
e(234)
Dual-Core.
deviceFamilyIsAMDSempronSI
(235)
The processor family is AMD Sempron
SI.
Device Group
335
book.book Page 336 Wednesday, March 6, 2013 12:37 AM
Table 13-6. Processor Device Family (continued)
Variable Name: DellProcessorDeviceFamily
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceFamilyIsAMDPhenomII(236) The processor family is AMD Phenom
II.
deviceFamilyIsAMDAthlonII(237) The processor family is AMD Athlon II.
deviceFamilyIsSixCoreAMDOptero The processor family is Six-Core AMD
n(238)
Opteron.
deviceFamilyIsAMDSempronM(239) The processor family is AMD Sempron
M.
deviceFamilyIsi860(250)
The processor family is i860.
deviceFamilyIsi960(251)
The processor family is i960.
deviceFamilyIsAMDOpteron6200
(61)
The processor family family is AMD
Opteron 6200 Series Processor.
deviceFamilyIsAMDOpteron4200
(61)
The processor family family is AMD
Opteron 4200 Series Processor.
Table 13-7. Cache Device Type
Variable Name: DellCacheDeviceType
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceTypeIsOther(1)
System cache type is not one of the
following:
deviceTypeIsUnknown(2)
System cache type is unknown.
deviceTypeIsInstruction(3)
System cache type is instruction.
deviceTypeIsData(4)
System cache type is data.
deviceTypeIsUnified(5)
System cache type is both instruction
and data.
336
Device Group
book.book Page 337 Wednesday, March 6, 2013 12:37 AM
Table 13-8.
Cache Device Level
Variable Name: DellCacheDeviceLevel
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceLevelIsOther(1)
Device level is not one of the following:
deviceLevelIsUnknown(2)
Device level is unknown.
deviceLevelIsPrimary(3)
Device level is primary.
deviceLevelIsSecondary(4)
Device level is secondary.
deviceLevelIsTertiary(5)
Device level is tertiary.
Table 13-9.
Cache Device Write Policy
Variable Name: DellCacheDeviceWritePolicy
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceWritePolicyIsOther(1)
Device write policy is not
one of the following:
deviceWritePolicyIsUnknown(2)
Device write policy is
unknown.
deviceWritePolicyIsWriteBack(3)
Device write policy is
write back.
deviceWritePolicyIsWriteThrough(4)
Device write policy is
write through.
deviceWritePolicyIsVariesByAddress(5)
Device write policy varies
by address.
deviceWritePolicyIsDeterminedByIO(6)
Device write policy is
determined by I/O query.
Device Group
337
book.book Page 338 Wednesday, March 6, 2013 12:37 AM
Table 13-10. Cache Device Status State
Variable Name: DellCacheDeviceStatusState
Data Type: Integer
Possible Data Values
Meaning of Data Value
other(1)
Device state is not one of the following:
unknown(2)
Device state is unknown.
enabled(3)
Device is enabled.
userDisabled(4)
Device is disabled by the user.
biosDisabled(5)
Device basic input/output system
(BIOS) is disabled.
Table 13-11. Cache Device ECC Type
Variable Name: DellPointingDeviceType
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceTypeIsOther(1)
Device type is not one of the following:
deviceTypeIsUnknown(2)
Device type is unknown.
deviceTypeIsAMouse(3)
Device type is a mouse.
deviceTypeIsATrackBall(4)
Device type is a track ball.
deviceTypeIsATrackPoint(5)
Device type is a track point.
deviceTypeIsAGlidePoint(6)
Device type is a glide point.
deviceTypeIsATouchPad(7)
Device type is a touch pad.
Table 13-12. Cache Device Associativity
Variable Name: DellCacheDeviceAssociativity
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceAssociativityIsOther(1)
Device associativity is not
one of the following:
338
Device Group
book.book Page 339 Wednesday, March 6, 2013 12:37 AM
Table 13-12. Cache Device Associativity (continued)
Variable Name: DellCacheDeviceAssociativity
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceAssociativityIsUnknown(2)
Device associativity is
unknown.
deviceAssociativityIsDirectMapped(3) Device is direct mapped.
deviceAssociativityIsTwoWaySetAsso
ciative(4)
Device is two-way set
associative.
deviceAssociativityIsFourWaySetAsso Device is four-way set
ciative(5)
associative.
deviceAssociativityIsFullyAssociative Device is fully associative.
(6)
deviceAssociativityIsEightWaySetAsso Device is eight-way set
ciative(7)
associative.
deviceAssociativityIsSixteenWaySet
Associative(8)
Device is sixteen-way set
associative.
deviceAssociativityIs12WaySetAssoc
iative(9)
Device is 12-way
Set-Associative.
deviceAssociativityIs24WaySetAssoc
iative(10)
Device is 24-way
Set-Associative.
deviceAssociativityIs32WaySetAssoc
iative(11)
Device is 32-way
Set-Associative.
deviceAssociativityIs48WaySetAssoc
iative(12)
Device is 48-way
Set-Associative.
deviceAssociativityIs64WaySetAssoc
iative(13)
Device is 64-way
Set-Associative.
Device Group
339
book.book Page 340 Wednesday, March 6, 2013 12:37 AM
Table 13-13. Cache Device Location
Variable Name: DellCacheDeviceLocation
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceLocationIsOther(1)
Device location is not one of the
following:
deviceLocationIsUnknown(2)
Device location is unknown.
deviceLocationIsInternal(3)
Device location is internal.
deviceLocationIsExternal(4)
Device location is external.
Table 13-14. Cache Device Static Random-Access Memory (SRAM) Type
Variable Name: DellCacheDeviceSRAMType
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceSRAMTypeIsOther(1)
Device SRAM type is not one of the
following:
deviceSRAMTypeIsUnknown(2)
Device SRAM type is unknown.
deviceSRAMTypeIsNonBurst(3)
Device SRAM type is nonburst.
deviceSRAMTypeIsBurst(4)
Device SRAM type is burst.
deviceSRAMTypeIsPipeBurst(5)
Device SRAM type is pipeburst.
deviceSRAMTypeIsSynchronous(6) Device SRAM type is synchronous.
deviceSRAMTypeIsAsynchronous(7) Device SRAM type is asynchronous.
Table 13-15. Memory Device Type Form Factor
Variable Name: DellMemoryDeviceFormFactor
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceFormFactorIsOther(1)
Device form factor is not one of
the following:
340
Device Group
book.book Page 341 Wednesday, March 6, 2013 12:37 AM
Table 13-15. Memory Device Type Form Factor (continued)
Variable Name: DellMemoryDeviceFormFactor
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceFormFactorIsUnknown(2)
Device form factor is unknown.
deviceFormFactorIsSIMM(3)
Device form factor is SIMM.
deviceFormFactorIsSIP(4)
Device form factor is SIP.
deviceFormFactorIsAChip(5)
Device form factor is a chip.
deviceFormFactorIsDIP(6)
Device form factor is DIP.
deviceFormFactorIsZIP(7)
Device form factor is ZIP.
deviceFormFactorIsAProprietaryCard Device form factor is a proprietary
(8)
card.
deviceFormFactorIsDIMM(9)
Device form factor is DIMM.
deviceFormFactorIsTSOP(10)
Device form factor is TSOP.
deviceFormFactorIsARowOfChips(11)
Device form factor is a row of
chips.
deviceFormFactorIsRIMM(12)
Device form factor is RIMM.
deviceFormFactorIsSODIMM(13)
Device form factor is SODIMM.
deviceFormFactorIsSRIMM(14)
Device form factor is SRIMM.
deviceFormFactorIsFBDIMM(15)
Device form factor is FB-DIMM.
Table 13-16. Memory Device Type
Variable Name: DellMemoryDeviceType
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceTypeIsOther(1)
Device type is not one of the following:
deviceTypeIsUnknown(2)
Device type is unknown.
deviceTypeIsDRAM(3)
Device type is DRAM.
deviceTypeIsEDRAM(4)
Device type is EDRAM.
Device Group
341
book.book Page 342 Wednesday, March 6, 2013 12:37 AM
Table 13-16. Memory Device Type (continued)
Variable Name: DellMemoryDeviceType
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceTypeIsVRAM(5)
Device type is VRAM.
deviceTypeIsSRAM(6)
Device type is SRAM.
deviceTypeIsRAM(7)
Device type is RAM.
deviceTypeIsROM(8)
Device type is ROM.
deviceTypeIsFLASH(9)
Device type is FLASH.
deviceTypeIsEEPROM(10)
Device type is EEPROM.
deviceTypeIsFEPROM(11)
Device type is FEPROM.
deviceTypeIsEPROM(12)
Device type is EPROM.
deviceTypeIsCDRAM(13)
Device type is CDRAM.
deviceTypeIs3DRAM(14)
Device type is 3DRAM.
deviceTypeIsSDRAM(15)
Device type is SDRAM.
deviceTypeIsSGRAM(16)
Device type is SGRAM.
deviceTypeIsRDRAM(17)
Device type is RDRAM.
deviceTypeIsDDR(18)
Device type is DDR.
deviceTypeIsDDR2(19)
Device type is DDR2.
deviceTypeIsDDR2FBDIMM(20)
Device type is DDR2 FB-DIMM.
deviceTypeIsDDR3(24)
Device type is DDR3.
deviceTypeIsFBD2(25)
Device type is FBD2.
342
Device Group
book.book Page 343 Wednesday, March 6, 2013 12:37 AM
Table 13-17. Memory Device Type Details
Variable Name: DellMemoryDeviceTypeDetails
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceTypeDetailIsOther(2)
The detailed device type is not one of the
following:
deviceTypeDetailIsUnknown(4)
The detailed device type is unknown.
deviceTypeDetailIsFastPaged
(8)
The detailed device type is fast paged.
deviceTypeDetailIsStaticColum The detailed device type is static column.
n(16)
deviceTypeDetailIsPseudoStati The detailed device type is pseudo-static.
c(32)
deviceTypeDetailIsRAMBUS(64)
The detailed device type is RAMBUS.
deviceTypeDetailIsSynchronous The detailed device type is synchronous.
(128)
deviceTypeDetailIsCMOS(256)
The detailed device type is CMOS.
deviceTypeDetailIsEDO(512)
The detailed device type is EDO.
deviceTypeDetailIsWindowDRAM
(1024)
The detailed device type is Window
DRAM.
deviceTypeDetailIsCacheDRAM
(2048)
The detailed device type is Cache
DRAM.
deviceTypeDetailIsNonVolatile The detailed device type is Non-volatile.
(4096)
deviceTypeDetailIsRegistered
(8192)
The detailed device type is registered.
deviceTypeDetailIsNonRegister The detailed device type is noned(16384)
registered.
Device Group
343
book.book Page 344 Wednesday, March 6, 2013 12:37 AM
Table 13-18. Generic Device Type
Variable Name: DellGenericDeviceType
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceTypeIsOther(1)
Device type is not one of the
following:
deviceTypeIsUnknown(2)
Device type is unknown.
deviceTypeIsAVideoDevice(3)
Device type is a video.
deviceTypeIsASCSIController(4)
Device type is a SCSI controller.
deviceTypeIsAnEthernetDevice(5)
Device type is Ethernet.
deviceTypeIsTokenRingDevice(6)
Device type is token ring.
deviceTypeIsASoundDevice(7)
Device type is sound.
Table 13-19. Memory Device Failure Modes
Variable Name: DellMemoryDeviceFailureModes
Data Type: Integer
NOTE: These values are bit masks, so combination values are possible.
Possible Data Values
Meaning of Data Value
(0)
Memory device has no
faults.
eccSingleBitCorrectionWarningRate(1)
Memory device has
exceeded the
Correctable Memory
Event warning rate.
eccSingleBitCorrectionFailureRate(2)
Memory device has
exceeded the
Correctable Memory
Event failure rate.
eccMultiBitFault(4)
Memory device has
encountered an
Uncorrectable Memory
Event.
344
Device Group
book.book Page 345 Wednesday, March 6, 2013 12:37 AM
Table 13-19. Memory Device Failure Modes (continued)
Variable Name: DellMemoryDeviceFailureModes
Data Type: Integer
NOTE: These values are bit masks, so combination values are possible.
Possible Data Values
Meaning of Data Value
eccSingleBitCorrectionLoggingDisabled(8) Correctable Memory
Event logging for
memory device has been
disabled.
deviceDisabledBySpareActivation(16)
Memory device is
disabled because of spare
memory activation.
Table 13-20. Network Device Connection Status
Variable Name: DellNetworkDeviceConnectionStatus
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(0)
Unable to determine connection status.
connected(1)
Media reports that device is connected.
disconnected(2)
Media reports that device is disconnected.
driverBad(3)
Driver cannot be opened to determine status.
driverDisabled(4)
Driver is disabled.
hardwareInitalizing(10)
Hardware is initializing.
hardwareResetting(11)
Hardware is resetting.
hardwareClosing(12)
Hardware is closing down.
hardwareNotReady(13)
Hardware is not ready.
Device Group
345
book.book Page 346 Wednesday, March 6, 2013 12:37 AM
Table 13-21. Network Device Teaming Flags
Variable Name: DellNetworkDeviceTeamingFlags
Data Type: Integer
NOTE: These values are bit fields, so combination values are possible.
Possible Data Values
Meaning of Data Value
undefined(0)
Teaming flags are undefined.
noTeam(1)
Device is not part of any team.
teamingEnabled(2)
Teaming is enabled.
adapterFaultToleranceMode(4) Adapter fault tolerance teaming mode.
loadBalancingMode(8)
Load balancing teaming mode.
Table 13-22. Network Device TOE Capability Flags
Variable Name: DellNetworkDeviceTOECapabilityFlags
Data Type: Integer
NOTE: These values are bit fields, so combination values are possible.
Possible Data Values
Meaning of Data Value
none(0)
Querying for TOE capability is not supported.
unknown(1)
Querying for TOE capability is supported but
query returned an error.
available(2)
Device has TOE capability.
notAvailable(4)
Device does not have TOE capability.
cannotBeDetermined(8)
Querying for TOE capability is supported but
an error prevented querying.
driverNotResponding(16)
Querying for TOE capability is supported but
driver did not respond to query.
346
Device Group
book.book Page 347 Wednesday, March 6, 2013 12:37 AM
Table 13-23. Network Device RDMA Capability Flags
Variable Name: DellNetworkDeviceRDMACapabilityFlags
Data Type: Integer
NOTE: These values are bit fields, so combination values are possible.
Possible Data Values
Meaning of Data Value
none(0)
Querying for RDMA capability is not
supported.
unknown(1)
Querying for RDMA capability is supported
but query returned an error.
available(2)
Device has RDMA capability.
notAvailable(4)
Device does not have RDMA capability.
cannotBeDetermined(8)
Querying for RDMA capability is supported
but an error prevented querying.
driverNotResponding(16)
Querying for RDMA capability is supported
but driver did not respond to query.
Table 13-24. Network Device iSCSI Capability Flags
Variable Name: DellNetworkDeviceiSCSICapabilityFlags
Data Type: Integer
NOTE: These values are bit fields, so combination values are possible.
Possible Data Values
Meaning of Data Value
none(0)
Querying for iSCSI capability is not supported.
unknown(1)
Querying for iSCSI capability is supported but
query returned an error.
available(2)
Device has iSCSI capability.
notAvailable(4)
Device does not have iSCSI capability.
cannotBeDetermined(8)
Querying for iSCSI capability is supported but
an error prevented querying.
driverNotResponding(16)
Querying for iSCSI capability is supported but
driver did not respond to query.
Device Group
347
book.book Page 348 Wednesday, March 6, 2013 12:37 AM
Table 13-25. Managed System Services Device Type
Variable Name: DellManagedSystemServicesDeviceType
Data Type: Integer
Possible Data Values
Meaning of Data Value
baseDevice(0)
Device type is base device.
optionalDevice(1)
Device type is optional device.
Table 13-26. SD Card Device Type
Variable Name: DellSDCardDeviceType
Data Type: Integer
Possible Data Values
Meaning of Data Value
other(1)
Device type is other.
unknown(2)
Device type is unknown.
hypervisor(3)
Device type is Hypervisor.
vFlash(4)
Device type is Virtual Flash (vFlash.)
Table 13-27. SD Card Device Config Capabilities
Variable Name: DellSDCardDeviceConfigCapabilities
Data Type: Integer
NOTE: These values are bit fields, so combination values are possible.
Possible Data Values
Meaning of Data Value
none(0)
SD card device has none of the following
capabilities.
sdCapable(1)
SD media can be enabled.
vFlashCapable(2)
Virtual Flash (vFlash) can be enabled.
348
Device Group
book.book Page 349 Wednesday, March 6, 2013 12:37 AM
Table 13-28. SD Card Device Config Settings
Variable Name: DellSDCardDeviceConfigSettings
Data Type: Integer
NOTE: These values are bit fields, so combination values are possible.
Possible Data Values
Meaning of Data Value
none(0)
SD card device has none of the following
settings.
sdEnabled(1)
SD media is enabled.
vFlashEnabled(2)
Virtual Flash (vFlash) is enabled.
Table 13-29. SD Card Device Card State
Variable Name: DellSDCardDeviceCardState
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
SD card state is none of the following states.
present(1)
Device is present.
ipmiReady(2)
Device is IPMI ready.
fullReady(4)
Device is full ready.
offline(8)
Device is offline.
failed(16)
Device is failed.
active(32)
Device is active.
bootable(64)
Device is bootable.
writeProtect(128)
Device is write-protected.
standby(256)
Device is in standby mode.
Table 13-30. SD Card Device Card Licensed
Variable Name: DellSDCardDeviceCardLicensed
Data Type: Integer
Possible Data Values
Meaning of Data Value
unlicensed(0)
SD card is not licensed by system vendor.
Device Group
349
book.book Page 350 Wednesday, March 6, 2013 12:37 AM
Variable Name: DellSDCardDeviceCardLicensed
Data Type: Integer
Possible Data Values
Meaning of Data Value
licensed(1)
SD card is licensed by system vendor.
ipmiReady(2)
Device is IPMI ready.
fullReady(4)
Device is full ready.
offline(8)
Device is offline.
failed(16)
Device is failed.
active(32)
Device is active.
bootable(64)
Device is bootable.
writeProtect(128)
Device is write-protected.
standby(256)
Device is in standby mode.
350
Device Group
book.book Page 351 Wednesday, March 6, 2013 12:37 AM
Slot Group
14
The Slot Group provides information about the types of slots that your
system supports. This management information base (MIB) group also
provides information about the voltages, capabilities, states, and settings that
are possible for these slots.
System Slot Group Table
The System Slot Group defines objects in the System Slot MIB table.
System Slot Table
The following object sets up the System Slot Table:
Name
systemSlotTable
Object ID
1.3.6.1.4.1.674.10892.1.1200.10
Description
Defines the System Slot Table.
Syntax
IntegerSystemStateTableEntry
Access
Not accessible
System Slot Table Entry
Name
systemSlotTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1
Description
Defines the System Slot Table entry.
Syntax
IntegerSystemSlotTableEntry
Access
Not accessible
Index
systemSlotchassisIndex, systemSlotIndex
Slot Group
351
book.book Page 352 Wednesday, March 6, 2013 12:37 AM
System Slot Chassis Index
Name
systemSlotchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
System Slot Index
Name
systemSlotIndex
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.2
Description
Defines the index (one-based) of the system slot in this chassis.
Syntax
DellObjectRange
Access
Read-only
System Slot State Capabilities Unique
Name
systemSlotStateCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.3
Description
Defines the capabilities of the system slot.
Syntax
DellSystemSlotStateCapabilities (See Table 14-1)
Access
Read-only
System Slot State Settings Unique
Name
systemSlotStateSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.4
Description
Defines the state of the system slot.
Syntax
DellSystemSlotStateSettings (See Table 14-2)
Access
Read-only
352
Slot Group
book.book Page 353 Wednesday, March 6, 2013 12:37 AM
System Slot Status
Name
systemSlotStatus
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.5
Description
Defines the status of the system slot.
Syntax
DellStatus
Access
Read-only
System Slot Current Usage
Name
systemSlotCurrentUsage
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.6
Description
Defines the current usage of the system slot.
Syntax
DellStatus
Access
Read-only
System Slot Type
Name
systemSlotType
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.7
Description
Defines the type of the system slot.
Syntax
DellSystemSlotType (See Table 14-3)
Access
Read-only
System Slot External Slot Name
Name
systemSlotSlotExternalSlotName
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.8
Description
Defines the external connector name of the system slot.
Syntax
DellString
Access
Read-only
Slot Group
353
book.book Page 354 Wednesday, March 6, 2013 12:37 AM
System Slot Length
Name
systemSlotLength
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.9
Description
Defines the length of the system slot.
Syntax
DellSystemSlotLength (See Table 14-5)
Access
Read-only
System Slot Slot ID
Name
systemSlotSlotID
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.10
Description
Defines the slot identification number of the system slot. A zero (0)
indicates that the slot is embedded on the motherboard.
Syntax
DellUnsigned32BitRange
Access
Read-only
System Slot Category
Name
systemSlotCategory
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.11
Description
Defines the system slot category.
Syntax
DellUnsigned32BitRange
Access
Read-only
System Slot Hot-Plug Bus Width
Name
systemSlotHotPlugBusWidth
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.12
Description
Defines the bus width of the hot-plug system slot.
Syntax
DellSystemSlotHotPlugBusWidth (See Table 14-7)
Access
Read-only
354
Slot Group
book.book Page 355 Wednesday, March 6, 2013 12:37 AM
System Slot Hot-Plug Slot Speed
Name
systemSlotHotPlugSlotSpeed
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.13
Description
Defines the slot speed in megahertz of the hot-plug system slot.
A zero (0) indicates that the slot speed is unknown.
Syntax
DellUnsigned32BitRange
Access
Read-only
System Slot Hot-Plug Adapter Speed
Name
systemSlotHotPlugAdapterSpeed
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.14
Description
Defines the adapter speed in megahertz of the hot-plug system
slot. A zero (0) indicates that the slot speed is unknown.
Syntax
DellUnsigned32BitRange
Access
Read-only
System Slot Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 14-1.
System Slot State Capabilities
Variable Name: DellSystemSlotStateCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
systemSlotHotPlugIsUnknown The system slot’s capabilities are unknown.
(1)
systemSlotHotPlugIsHotPlug The system slot supports hot-plug.
gableCapable(2)
systemSlotHotPlugCanBePower The system slot power (and corresponding
edOn(4)
light-emitting diode [LED]) can be
powered on.
Slot Group
355
book.book Page 356 Wednesday, March 6, 2013 12:37 AM
Table 14-1. System Slot State Capabilities (continued)
Variable Name: DellSystemSlotStateCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
systemSlotHotPlugCanSignal The system slot attention state
Attention(8)
(and corresponding LED) can be set.
systemSlotHotPlugCanSignal Power on fault (and corresponding LED) can
PowerFault(16)
be detected due to a short or overcurrent.
systemSlotHotPlugCanSignal Adapter (card) present in slot (may not be
AdapterPresent(32)
powered) can be detected.
systemSlotHotPlugCanSignal The system slot power button can be pressed
PowerButtonPressed(64)
to signal a toggle of the power state.
canSupportAllHotPlugCapabi The system slot can support all
lities(126)
hot-plug capabilities.
systemSlotHotPlugIsUnknown The system slot’s capabilities are unknown.
(1)
systemSlotCanProvide5Volts The system slot can provide a
(128)
5-volt (V) supply.
systemSlotCanProvide3Point The system slot can provide a 3.3-V supply.
3Volts(256)
systemSlotCanSignalIfShared The system slot’s opening, if shared with
(512)
another slot, can be detected.
systemSlotCanSupportCard16 The system slot can support
(1024)
PC Card-16.
systemSlotCanSupportCardBus The system slot can support CardBus.
(2048)
systemSlotCanSupportZoomVid The system slot can support Zoom Video.
eo(4096)
systemSlotCanSupportModem The system slot can support modem
RingResume(8192)
ring resume.
systemSlotCanSupportPMESig The system slot can support Power
nal(16384)
Management Enable (PME#) signal.
canSupportAllSlotCapabilit The system slot can support all
ies(32640)
slot capabilities.
356
Slot Group
book.book Page 357 Wednesday, March 6, 2013 12:37 AM
Table 14-2.
System Slot State Settings
Variable Name: DellSystemSlotStateSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
systemSlotHotPlugIsUnknown(1)
The system slot’s capabilities are
unknown.
systemSlotHotPlugIsHotPluggable(2) The system slot supports hot-plug.
systemSlotHotPlugIsPoweredOn(4)
The system slot power (and
corresponding LED) can be
powered on.
systemSlotHotPlugIsAtAttention(8)
The system slot attention state (and
corresponding LED) can be set.
systemSlotHotPlugIsHotPluggable(2) The system slot supports hot-plug.
systemSlotHotPlugIsPoweredOn(4)
The system slot power (and
corresponding LED) is on.
systemSlotHotPlugIsAtAttention(8)
The system slot attention state
(and corresponding LED) is on.
systemSlotHotPlugHasPowerFaulted
(16)
Power on fault (and corresponding
LED) was detected due to a short
or overcurrent.
systemSlotHotPlugAdapterIsPresent Adapter (card) present in slot
(32)
(may not be powered).
systemSlotHotPlugAdapterPresentAnd Adapter (card) present in slot
PoweredOn(36)
and powered.
systemSlotHotPlugPowerButtonPressed The system slot power button
(64)
pressed to signal a toggle of the
power state.
systemSlotProvides5Volts(128)
The system slot provides a 5-V
supply.
systemSlotProvides3Point3Volts(256) The system slot provides a 3.3-V
supply.
systemSlotIsShared(512)
The slot’s opening is shared with
another slot.
Slot Group
357
book.book Page 358 Wednesday, March 6, 2013 12:37 AM
Table 14-2. System Slot State Settings (continued)
Variable Name: DellSystemSlotStateSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
systemSlotSupportsCard16(1024)
The system slot supports PC
Card-16.
systemSlotSupportsCardBus(2048)
The system slot supports
CardBus.
systemSlotSupportsZoomVideo(4096)
The system slot supports zoom
video.
systemSlotSupportsModemRingResume The system slot supports modem
(8192)
ring resume.
systemSlotSupportsPMESignal(16384) The system slot supports power
management enable (PME#)
signal.
supportsPMEand3P3Vand5VandHotPlugg The system slot supports power
able(16770)
management enable.
supportsPMEand3P3Vand5VhasAdapterO The system slot supports power
n(16804)
management event (PME),
supplies 3.3 V, and supplies 5 V.
The adapter is on.
supportsPMEand3P3Vand5VhasAdapter The system slot supports PME,
OnandisHotPluggable(16806)
supplies 3.3 V, and supplies 5 V.
The adapter is on and the system
slot is hot pluggable.
supportsPMEand3P3VIsSharedand5Vhas The system slot supports PME,
AdapterOnandisHotPluggable(17316) supplies 3.3 V, supplies 5 V, and
shares a slot opening. The adapter
is on and the system slot is
hot pluggable.
358
Slot Group
book.book Page 359 Wednesday, March 6, 2013 12:37 AM
Table 14-3.
System Slot Type
Variable Name: DellSystemSlotType
Data Type: Integer
Possible Data Values
Meaning of Data Value
systemSlotIsOther(1)
The system slot type is not one of
following:
systemSlotIsUnknown(2)
The system slot type is unknown.
systemSlotIsISA(3)
The system slot is Industry
Standard Architecture (ISA).
systemSlotIsMCA(4)
The system slot is Micro Channel
Architecture (MCA).
systemSlotIsEISA(5)
The system slot is Extended Industry
Standard Architecture (EISA).
systemSlotIsPCI(6)
The system slot is Peripheral
Component Interconnect (PCI).
systemSlotIsPCMCIA(7)
The system slot is compliant with
the Personal Computer Memory
Card International Association
(PCMCIA) standards.
systemSlotIsVLVESA(8)
The system slot is Very Low Voltage
Enterprise System Architecture
(VLVESA).
systemSlotIsProprietary(9)
The system slot is proprietary.
systemSlotIsProcessorCard(10)
The system slot is a processor card.
systemSlotIsProprietaryMemory(11)
The system slot is proprietary memory.
systemSlotIsIORiserCard(12)
The system slot is an I/O riser card.
systemSlotIsNuBUS(13)
The system slot is a NuBus.
systemSlotIsPCI66MHz(14)
The system slot is a PCI66MHz.
systemSlotIsAGP(15)
The system slot is an Advanced
Graphics Port (AGP).
systemSlotIsAGP2X(16)
The system slot is an AGP 2x card.
systemSlotIsAGP4X(17)
The system slot is an AGP 4x card.
Slot Group
359
book.book Page 360 Wednesday, March 6, 2013 12:37 AM
Table 14-3. System Slot Type (continued)
Variable Name: DellSystemSlotType
Data Type: Integer
Possible Data Values
Meaning of Data Value
systemSlotIsPC98C20(18)
The system slot is a PC-98/C20.
systemSlotIsPC98C24(19)
The system slot is a PC-98/C24.
systemSlotIsPC98E(20)
The system slot type is PC-98/E.
systemSlotIsPC98LocalBus(21)
The system slot type is a PC-98
local bus.
systemSlotIsPC98Card(22)
The system slot type is a PC-98 card.
systemSlotIsPCIX(23)
The system slot type is a PCIX card.
systemSlotIsPCIExpress(24)
The system slot type is a PCI
Express card.
systemSlotIsAGP8X(25)
The system slot type is an AGP 8x
card.
systemSlotIsPCIExpressX1(166)
The system slot type is a PCI
Express x1.
systemSlotIsPCIExpressX2(167)
The system slot type is a PCI
Express x2.
systemSlotIsPCIExpressX4(168)
The system slot type is a PCI
Express x4.
systemSlotIsPCIExpressX8(169)
The system slot type is a PCI
Express x8.
systemSlotIsPCIExpressX16(170)
The system slot type is a PCI
Express x16.
systemSlotIsPCIExpressGen2(171)
The system slot type is PCI Express
Gen 2.
systemSlotIsPCIExpressGen2X1(172)
The system slot type is PCI Express
Gen 2 x1.
systemSlotIsPCIExpressGen2X2(173) The system slot type is PCI Express
Gen 2 x2.
360
Slot Group
book.book Page 361 Wednesday, March 6, 2013 12:37 AM
Table 14-3.
System Slot Type (continued)
Variable Name: DellSystemSlotType
Data Type: Integer
Possible Data Values
Meaning of Data Value
systemSlotIsPCIExpressGen2X4(174)
The system slot type is PCI Express
Gen 2 x4.
systemSlotIsPCIExpressGen2X8(175)
The system slot type is PCI Express
Gen 2 x8.
systemSlotIsPCIExpressGen2X16(176) The system slot type is PCI Express
Gen 2 x16.
Table 14-4.
System Slot Usage
Variable Name: DellSystemSlotUsage
Data Type: Integer
Possible Data Values
Meaning of Data Value
systemSlotUsageIsOther(1)
The system slot usage is not one of
following:
systemSlotUsageIsUnknown(2)
The system slot usage is unknown.
systemSlotUsageIsAvailable(3) The system slot is available.
systemSlotUsageIsInUse(4)
Table 14-5.
The system slot is in use.
System Slot Length
Variable Name: DellSystemSlotLength
Data Type: Integer
Possible Data Values
Meaning of Data Value
systemSlotLengthIsOther(1)
The system slot length is not one of
following:
systemSlotLengthIsUnknown(2) The system slot length is unknown.
systemSlotLengthIsShort(3)
The system slot length is short.
systemSlotLengthIsLong(4)
The system slot length is long.
Slot Group
361
book.book Page 362 Wednesday, March 6, 2013 12:37 AM
Table 14-6. System Slot Category
Variable Name: DellSystemSlotCategory
Data Type: Integer
Possible Data Values
Meaning of Data Value
systemSlotCategoryIsOther(1)
The system slot category is not
one of following:
systemSlotCategoryIsUnknown(2)
The system slot category is
unknown.
systemSlotCategoryIsBusConnector(3) The system slot is a bus
connector.
systemSlotCategoryIsPCMCIA(4)
The system slot category is
PCMCIA.
systemSlotCategoryIsMotherboard(5)
The system slot is a
motherboard.
Table 14-7. Hot-Plug Bus Width
Variable Name: DellSystemSlotHotPlugBusWidth
Data Type: Integer
Possible Data Values
Meaning of Data Value
busWidthIsOther(1)
The system slot bus width is not one of following:
busWidthIsUnknown(2)
The system slot bus width is unknown.
busWidthIs8bits(3)
The system slot bus width is 8 bits.
busWidthIs16bits(4)
The system slot bus width is 16 bits.
busWidthIs32bits(5)
The system slot bus width is 32 bits.
busWidthIs64bits(6)
The system slot bus width is 64 bits.
busWidthIs128bits(7)
The system slot bus width is 128 bits.
busWidthIs1xOrx1(8)
The system slot bus width is 1x or x1.
busWidthIs2xOrx2(9)
The system slot bus width is 2x or x2.
busWidthIs4xOrx4(10)
The system slot bus width is 4x or x4.
busWidthIs8xOrx8(11)
The system slot bus width is 8x or x8.
362
Slot Group
book.book Page 363 Wednesday, March 6, 2013 12:37 AM
Table 14-7.
Hot-Plug Bus Width (continued)
Variable Name: DellSystemSlotHotPlugBusWidth
Data Type: Integer
Possible Data Values
Meaning of Data Value
busWidthIs12xOrx12(12)
The system slot bus width is 12x or x12.
busWidthIs16xOrx16(13)
The system slot bus width is 16x or x16.
busWidthIs32xOrx32(14)
The system slot bus width is 32x or x32.
NOTE: System slot bus width of type n bits are for parallel buses such as PCI.
NOTE: System slot bus width of type nx or xn are for serial buses such as
PCI Express.
Slot Group
363
book.book Page 364 Wednesday, March 6, 2013 12:37 AM
364
Slot Group
book.book Page 365 Wednesday, March 6, 2013 12:37 AM
15
Memory Group
The Memory Group provides information about the physical memory in your
system. Variables in this group include error correction type, location, and
different types of memory use, such as cache, flash, system, video, and
nonvolatile memory.
Physical Memory Tables
The following management information base (MIB) tables define the objects
in the Memory Group:
•
"Physical Memory Array Table" on page 365
•
"Physical Memory Array Mapped Table" on page 370
•
"Physical Memory Configuration Table" on page 373
•
"Physical Memory Logging Table" on page 376
•
"Redundant Memory Unit Table" on page 378
•
"Physical Memory Card Table" on page 381
Physical Memory Array Table
The physical memory array is the entire physical memory of a system.
The example that follows shows variable values for a system that has one
128-megabyte (MB) dual in-line memory module (DIMM):
•
physicalMemoryArrayMaximumSize = 2,097,152 kilobytes (KB) or
2 gigabytes (GB)
•
physicalMemoryArrayTotalNumberSockets = 4 (the example system has
four DIMM slots on the motherboard)
•
physicalMemoryArrayInUseNumberSockets = 1 (there is only one DIMM
installed)
Memory Group
365
book.book Page 366 Wednesday, March 6, 2013 12:37 AM
The following object sets up the Physical Memory Array Table:
Name
physicalMemoryArrayTable
Object ID
1.3.6.1.4.1.674.10892.1.1300.10
Description
Defines the Physical Memory Array Table.
Syntax
PhysicalMemoryArrayTableEntry
Access
Not accessible
Physical Memory Array Table Entry
Name
physicalMemoryArrayTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1
Description
Defines the Physical Memory Array Table entry.
Syntax
PhysicalMemoryArrayTableEntry
Access
Not accessible
Index
physicalMemoryArraychassisIndex, physicalMemoryArrayIndex
Physical Memory Array Chassis Index
Name
physicalMemoryArraychassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Physical Memory Array Index
Name
physicalMemoryArrayIndex
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.2
Description
Defines the index (one-based) of the physical memory array in
this chassis.
Syntax
DellObjectRange
Access
Read-only
366
Memory Group
book.book Page 367 Wednesday, March 6, 2013 12:37 AM
Physical Memory Array State Capabilities
Name
physicalMemoryArrayStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.3
Description
Defines the capabilities of the physical memory array.
Syntax
DellStateCapabilities
Access
Read-only
Physical Memory Array State Settings
Name
physicalMemoryArrayStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.4
Description
Defines the state of the physical memory array.
Syntax
DellStateSettings
Access
read-write
Physical Memory Array Status
Name
physicalMemoryArrayStatus
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.5
Description
Defines the status of the physical memory array.
Syntax
DellStatus
Access
Read-only
Physical Memory Array Use
Name
physicalMemoryArrayUse
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.6
Description
Defines the use of the physical memory array.
Syntax
DellPhysicalMemoryArrayUse (See Table 15-2)
Access
Read-only
Memory Group
367
book.book Page 368 Wednesday, March 6, 2013 12:37 AM
Physical Memory Array Error Checking and Correcting (ECC) Type
Name
physicalMemoryArrayECCType
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.7
Description
Defines the ECC type used by the physical memory array.
Syntax
DellPhysicalMemoryArrayECCType (See Table 15-2)
Access
Read-only
Physical Memory Array Location
Name
physicalMemoryArrayLocation
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.8
Description
Defines the location of the physical memory array.
Syntax
DellPhysicalMemoryArrayLocation (See Table 15-1)
Access
Read-only
Physical Memory Array Maximum Size
Name
physicalMemoryArrayMaximumSize
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.9
Description
Defines the size in KB of the physical memory array.
Syntax
DellUnsigned32BitRange
Access
Read-only
Physical Memory Array Total Number Sockets
Name
physicalMemoryArrayTotalNumberSockets
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.10
Description
Defines the total number of memory sockets available for the
physical memory array.
Syntax
DellUnsigned32BitRange
Access
Read-only
368
Memory Group
book.book Page 369 Wednesday, March 6, 2013 12:37 AM
Physical Memory Array In Use Number Sockets
Name
physicalMemoryArrayInUseNumberSockets
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.11
Description
Defines the total number of memory sockets in use by the
physical memory array.
Syntax
DellUnsigned32BitRange
Access
Read-only
Physical Memory Array ECC Error Nonrecoverable Threshold
Name
physicalMemoryArrayECCErrorNonRecoverbeThreshold
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.12
Description
Defines the value of the physical memory array Error Checking and
Correction (ECC) error nonrecoverable threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Physical Memory Array ECC Error Critical Threshold
Name
physicalMemoryArrayECCErrorCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.13
Description
Defines the value of the physical memory array ECC error critical
threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Physical Memory Array ECC Error Noncritical Threshold
Name
physicalMemoryArrayECCErrorNonCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.14
Description
Defines the value of the physical memory array ECC error
noncritical threshold.
Syntax
DellSigned32BitRange
Access
read-write
Memory Group
369
book.book Page 370 Wednesday, March 6, 2013 12:37 AM
Physical Memory Array Redundant Memory Unit Index Reference
Name
physicalMemoryArrayRedundantMemoryUnitIndex
Reference
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.15
Description
Defines the index to the associated Redundant Memory Unit in
this chassis.
Syntax
DellObjectRange
Access
Read-only
Physical Memory Array Mapped Table
The physical memory array is divided into memory array mapped addresses.
The following object sets up the Physical Memory Array Mapped Table:
Name
physicalMemoryArrayMappedTable
Object ID
1.3.6.1.4.1.674.10892.1.1300.20
Description
Defines the Physical Memory Array Mapped Table.
Syntax
PhysicalMemoryArrayMappedTableEntry
Access
Not accessible
Physical Memory Array Mapped Table Entry
Name
PhysicalMemoryArrayMappedTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1300.20.1
Description
Defines the Physical Memory Array Mapped Table entry.
Syntax
PhysicalMemoryArrayMappedTableEntry
Access
Not accessible
Index
physicalMemoryArrayMappedchassisIndex,
physicalMemoryArrayMappedIndex
370
Memory Group
book.book Page 371 Wednesday, March 6, 2013 12:37 AM
Physical Memory Array Mapped Chassis Index
Name
physicalMemoryArrayMappedchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1300.20.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Physical Memory Array Mapped Index
Name
physicalMemoryArrayMappedIndex
Object ID
1.3.6.1.4.1.674.10892.1.1300.20.1.2
Description
Defines the index (one-based) of the memory array mapped
address in this chassis.
Syntax
DellObjectRange
Access
Read-only
Physical Memory Array Mapped State Capabilities
Name
physicalMemoryArrayMappedStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1300.20.1.3
Description
Defines the capabilities of the memory array mapped address.
Syntax
DellStateCapabilities
Access
Read-only
Physical Memory Array Mapped State Settings
Name
physicalMemoryArrayMappedStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1300.20.1.4
Description
Defines the state of the memory array mapped address.
Syntax
DellStateSettings
Access
Read-write
Memory Group
371
book.book Page 372 Wednesday, March 6, 2013 12:37 AM
Physical Memory Array Mapped Status
Name
physicalMemoryArrayMappedStatus
Object ID
1.3.6.1.4.1.674.10892.1.1300.20.1.5
Description
Defines the status of the memory array mapped address.
Syntax
DellStatus
Access
Read-only
Physical Memory Array Index Reference
Name
physicalMemoryArrayIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1300.20.1.6
Description
Defines the index to the associated physical memory array in this
chassis.
Syntax
DellObjectRange
Access
Read-only
Physical Memory Array Mapped Starting Address
Name
physicalMemoryArrayMappedStartingAddress
Object ID
1.3.6.1.4.1.674.10892.1.1300.20.1.7
Description
Defines the physical starting address in KB of the memory array
mapped address.
Syntax
DellUnsigned64BitRange
Access
Read-only
Physical Memory Array Mapped Ending Address
Name
physicalMemoryArrayMappedEndingAddress
Object ID
1.3.6.1.4.1.674.10892.1.1300.20.1.8
Description
Defines the physical ending address in KB of the memory array
mapped address.
Syntax
DellUnsigned64BitRange
Access
Read-only
372
Memory Group
book.book Page 373 Wednesday, March 6, 2013 12:37 AM
Physical Memory Array Mapped Partition Width
Name
physicalMemoryArrayMappedPartitionWidth
Object ID
1.3.6.1.4.1.674.10892.1.1300.20.1.9
Description
Defines the number of memory devices that form a single row in
the memory array mapped address. A zero (0) indicates that the
number is unknown.
Syntax
DellUnsigned32BitRange
Access
Read-only
Physical Memory Configuration Table
This table defines how the physical memory of a system chassis is set up, for
example, which redundant memory types are supported and whether
redundant memory is active.
The following object sets up the Physical Memory Configuration Table:
Name
physicalMemoryConfigTable
Object ID
1.3.6.1.4.1.674.10892.1.1300.30
Description
Defines the Physical Memory Configuration Table.
Syntax
SEQUENCE OF PhysicalMemoryConfigTableEntry
Access
Not accessible
Physical Memory Configuration Table Entry
Name
physicalMemoryConfigTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1300.30.1
Description
Defines the Physical Memory Configuration Table entry.
Syntax
PhysicalMemoryConfigTableEntry
Access
Not accessible
Index
physicalMemoryConfigChassisIndex,
physicalMemoryConfigIndex
Memory Group
373
book.book Page 374 Wednesday, March 6, 2013 12:37 AM
Physical Memory Configuration Chassis Index
Name
physicalMemoryConfigChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1300.30.1.1
Description
Defines the index (one-based) of the chassis associated with the
physical memory configuration.
Syntax
DellObjectRange
Access
Read-only
Physical Memory Configuration Index
Name
physicalMemoryConfigIndex
Object ID
1.3.6.1.4.1.674.10892.1.1300.30.1.2
Description
Defines the index (one-based) of the physical memory
configuration.
Syntax
DellObjectRange
Access
Read-only
Physical Memory Configuration State Capabilities
Name
physicalMemoryConfigStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1300.30.1.3
Description
Defines the state capabilities of the physical memory configuration.
Syntax
DellPhysicalMemoryConfigStateCapabilities
Access
Read-only
Physical Memory Configuration State Settings
Name
physicalMemoryConfigStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1300.30.1.4
Description
Defines the state settings of the physical memory configuration.
Syntax
DellPhysicalMemoryConfigStateSettings
Access
Read-write
374
Memory Group
book.book Page 375 Wednesday, March 6, 2013 12:37 AM
Physical Memory Configuration Status
Name
physicalMemoryConfigStatus
Object ID
1.3.6.1.4.1.674.10892.1.1300.30.1.5
Description
Defines the status of the physical memory configuration.
Syntax
DellStatus
Access
Read-only
Physical Memory Configuration Redundant Capabilities
Name
physicalMemoryConfigRedundantCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1300.30.1.6
Description
Defines the redundant capabilities of the physical memory.
Syntax
DellPhysicalMemoryConfigRedundantCapabilities
Access
Read-only
Physical Memory Configuration Redundant Settings
Name
physicalMemoryConfigRedundantSettings
Object ID
1.3.6.1.4.1.674.10892.1.1300.30.1.7
Description
Defines the redundant settings of the physical memory.
Syntax
DellPhysicalMemoryConfigRedundantSettings
Access
Read-write
Physical Memory Configuration MOM Capabilities
Name
physicalMemoryConfigMOMCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1300.30.1.8
Description
Defines the Memory Operating Mode capabilities of the
physical memory.
Syntax
DellPhysicalMemoryConfigMOMCapabilities
Access
Read-only
Memory Group
375
book.book Page 376 Wednesday, March 6, 2013 12:37 AM
Physical Memory Configuration MOM Settings
Name
physicalMemoryConfigMOMSettings
Object ID
1.3.6.1.4.1.674.10892.1.1300.30.1.9
Description
Defines the Memory Operating Mode settings of the physical
memory.
Syntax
DellPhysicalMemoryConfigMOMSettings
Access
Read-only
Physical Memory Logging Table
This table defines the conditions for logging system memory events.
The following object sets up the Physical Memory Logging Table:
Name
physicalMemoryLoggingTable
Object ID
1.3.6.1.4.1.674.10892.1.1300.40
Description
Defines the Physical Memory Logging Table.
Syntax
SEQUENCE OF PhysicalMemoryLoggingTableEntry
Access
Not accessible
Physical Memory Logging Table Entry
Name
physicalMemoryLoggingTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1300.40.1
Description
Defines the Physical Memory Logging Table entry.
Syntax
PhysicalMemoryLoggingTableEntry
Access
Not accessible
Index
physicalMemoryLoggingChassisIndex,
physicalMemoryLoggingIndex
376
Memory Group
book.book Page 377 Wednesday, March 6, 2013 12:37 AM
Physical Memory Logging Chassis Index
Name
physicalMemoryLoggingChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1300.40.1.1
Description
Defines the index (one-based) of the chassis associated with the
physical memory logging.
Syntax
DellObjectRange
Access
Read-only
Physical Memory Logging Index
Name
physicalMemoryLoggingIndex
Object ID
1.3.6.1.4.1.674.10892.1.1300.40.1.2
Description
Defines the index (one-based) of the physical memory logging.
Syntax
DellObjectRange
Access
Read-only
Physical Memory Logging Capabilities
Name
physicalMemoryLoggingCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1300.40.1.3
Description
Defines the capabilities of the physical memory logging.
Syntax
DellPhysicalMemoryLoggingCapabilities
Access
Read-only
Physical Memory Logging Settings
Name
physicalMemoryLoggingSettings
Object ID
1.3.6.1.4.1.674.10892.1.1300.40.1.4
Description
Defines the settings of the physical memory logging.
Syntax
DellPhysicalMemoryLoggingSettings
Access
Read-write
Memory Group
377
book.book Page 378 Wednesday, March 6, 2013 12:37 AM
Physical Memory Logging Status
Name
physicalMemoryLoggingStatus
Object ID
1.3.6.1.4.1.674.10892.1.1300.40.1.5
Description
Defines the status of the physical memory logging.
Syntax
DellStatus
Access
Read-only
Redundant Memory Unit Table
This table reports the status of redundant memory within a particular system
chassis.
The following object sets up the Redundant Memory Unit Table:
Name
redundantMemoryUnitTable
Object ID
1.3.6.1.4.1.674.10892.1.1300.50
Description
Defines the Redundant Memory Unit Table.
Syntax
SEQUENCE OF RedundantMemoryUnitTableEntry
Access
Not accessible
378
Memory Group
book.book Page 379 Wednesday, March 6, 2013 12:37 AM
Redundant Memory Unit Table Entry
Name
redundantMemoryUnitTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1300.50.1
Description
Defines the Redundant Memory Unit Table entry.
Syntax
RedundantMemoryUnitTableEntry
Access
Not accessible
Index
redundantMemoryUnitChassisIndex,
redundantMemoryUnitIndex
Redundant Memory Unit Chassis Index
Name
redundantMemoryUnitChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1300.50.1.1
Description
Defines the index (one-based) of the chassis associated with the
redundant memory unit.
Syntax
DellObjectRange
Access
Read-only
Redundant Memory Unit Index
Name
redundantMemoryUnitIndex
Object ID
1.3.6.1.4.1.674.10892.1.1300.50.1.2
Description
Defines the index (one-based) of the redundant memory unit.
Syntax
DellObjectRange
Access
Read-only
Redundant Memory Unit State Capabilities
Name
redundantMemoryUnitStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1300.50.1.3
Description
Defines the state capabilities of the redundant memory unit.
Syntax
DellStateCapabilities
Access
Read-only
Memory Group
379
book.book Page 380 Wednesday, March 6, 2013 12:37 AM
Redundant Memory Unit State Settings
Name
redundantMemoryUnitStatesettings
Object ID
1.3.6.1.4.1.674.10892.1.1300.50.1.4
Description
Defines the state settings of the redundant memory unit.
Syntax
DellStateSettings
Access
Read-write
Redundant Memory Unit Redundancy Status
Name
redundantMemoryUnitRedundancyStatus
Object ID
1.3.6.1.4.1.674.10892.1.1300.50.1.5
Description
Defines the redundancy status of the redundant memory unit.
Syntax
DellStatusRedundancy
Access
Read-only
Redundant Memory Unit Name
Name
redundantMemoryUnitName
Object ID
1.3.6.1.4.1.674.10892.1.1300.50.1.6
Description
Defines the name of the redundant memory unit.
Syntax
DellString
Access
Read-only
Redundant Memory Unit Status
Name
redundantMemoryUnitStatus
Object ID
1.3.6.1.4.1.674.10892.1.1300.50.1.7
Description
Defines the status of the redundant memory unit.
Syntax
DellStatus
Access
Read-only
380
Memory Group
book.book Page 381 Wednesday, March 6, 2013 12:37 AM
Physical Memory Card Table
This table defines the name of the memory card, the total number of device
slots present on the memory card, and the number of memory device slots in
use on the memory card.
The following objects set up the Physical Memory Card Table:
Physical Memory Card Table
Name
physicalMemoryCardTable
Object ID
1.3.6.1.4.1.674.10892.1.1300.60
Description
Defines the Physical Memory Card Table.
Syntax
SEQUENCE OF PhysicalMemoryCardTableEntry
Access
Not accessible
Physical Memory Card Table Entry
Name
physicalMemoryCardTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1300.60.1
Description
Defines the Physical Memory Card Table Entry.
Syntax
PhysicalMemoryCardTableEntry
Access
Not accessible
Index
physicalMemoryCardChassisIndex, physicalMemoryCardIndex
Physical Memory Card Chassis Index
Name
physicalMemoryCardChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1300.60.1.1
Description
Defines the index (one-based) of the associated chassis.
Syntax
DellObjectRange
Access
Read-only
Memory Group
381
book.book Page 382 Wednesday, March 6, 2013 12:37 AM
Physical Memory Card Index
Name
physicalMemoryCardIndex
Object ID
1.3.6.1.4.1.674.10892.1.1300.60.1.2
Description
Defines the index (one-based) of the Physical Memory Card.
Syntax
DellObjectRange
Access
Read-only
Physical Memory Card State Capabilities
Name
physicalMemoryCardStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1300.60.1.3
Description
Defines the state capabilities of the Physical Memory Card.
Syntax
DellStateCapabilities
Access
Read-only
Physical Memory Card State Settings
Name
physicalMemoryCardStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1300.60.1.4
Description
Defines the state settings of the Physical Memory Card.
Syntax
DellStateSettings
Access
Read-write
Physical Memory Card Status
Name
physicalMemoryCardStatus
Object ID
1.3.6.1.4.1.674.10892.1.1300.60.1.5
Description
Defines the status of the Physical Memory Card.
Syntax
DellStatus
Access
Read-only
382
Memory Group
book.book Page 383 Wednesday, March 6, 2013 12:37 AM
Physical Memory Card Name
Name
physicalMemoryCardName
Object ID
1.3.6.1.4.1.674.10892.1.1300.60.1.6
Description
Defines the name of the Physical Memory Card.
Syntax
DellString
Access
Read-only
Physical Memory Card Total Number Sockets
Name
physicalMemoryCardTotalNumberSockets
Object ID
1.3.6.1.4.1.674.10892.1.1300.60.1.7
Description
Defines the total number of memory sockets available on the
Physical Memory Card. 2,147,483,647 indicates an unknown
number of sockets.
Syntax
DellUnsigned32BitRange
Access
Read-only
Physical Memory Card In Use Number Sockets
Name
physicalMemoryCardInUseNumberSockets
Object ID
1.3.6.1.4.1.674.10892.1.1300.60.1.8
Description
Defines the number of memory sockets in use on the Physical
Memory Card. Zero indicates that the Physical Memory Card is
not installed or has a configuration error.
Syntax
DellUnsigned32BitRange
Access
Read-only
Memory Group
383
book.book Page 384 Wednesday, March 6, 2013 12:37 AM
Physical Memory Card Physical Memory Array Index Reference
Name
physicalMemoryCardPhyMemArrayIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1300.60.1.9
Description
Defines the index (one-based) of the Physical Memory Array
Table entry for the physical memory array with the same chassis
index that this physical memory card is associated with.
Syntax
DellObjectRange
Access
Read-only
Memory Group Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 15-1. Physical Memory Array Location
Variable Name: DellPhysicalMemoryArrayLocation
Data Type: Integer
Possible Data Values
Meaning of Data Value
memoryArrayLocationIsOther(1)
The memory array
location is not one of the
following:
memoryArrayUseIsUnknown(2)
The memory array use is
unknown.
memoryArrayUseIsSystemMemory(3)
The memory array is
system memory.
memoryArrayUseIsVideoMemory(4)
The memory array is video
memory.
memoryArrayUseIsFLASHMemory(5)
The memory array is
FLASH memory.
memoryArrayUseIsNonVolatileRAMMemory(6) The memory array is
nonvolatile RAM.
memoryArrayUseIsCacheMemory(7)
384
Memory Group
The memory array is cache
memory.
book.book Page 385 Wednesday, March 6, 2013 12:37 AM
Table 15-1.
Physical Memory Array Location (continued)
Variable Name: DellPhysicalMemoryArrayLocation
Data Type: Integer
Possible Data Values
Meaning of Data Value
memoryArrayLocationIsPCMCIA(8)
The memory array
location is a Personal
Computer Memory Card
International Association
(PCMCIA) option card.
memoryArrayLocationIsProprietary(9)
The memory array
location is a proprietary
option card.
memoryArrayLocationIsNUBUS(10)
The memory array
location is a NuBus bus.
memoryArrayLocationIsPC98C20(11)
The memory array
location is a PC-98/C20
option card.
memoryArrayLocationIsPC98C24(12)
The memory array
location is a PC-98/C24
option card.
memoryArrayLocationIsPC98E(13)
The memory array
location is a PC-98/E
option card.
memoryArrayLocationIsPC98LocalBus(14)
The memory array
location is a PC-98/Local
bus option card.
memoryArrayLocationIsPC98Card(15)
The memory array
location is a PC-98/Card
slot option card.
Memory Group
385
book.book Page 386 Wednesday, March 6, 2013 12:37 AM
Table 15-2. Physical Memory Array ECC Type Definitions
Variable Name: DellPhysicalMemoryArrayECCType
Data Type: Integer
Possible Data Values
Meaning of Data Value
memoryArrayECCTypeIsOther(1)
There is not one of the following:
memoryArrayECCTypeIsUnknown(2)
The memory array ECC type is
unknown.
memoryArrayECCTypeIsNone(3)
The memory array ECC type is
none.
memoryArrayECCTypeIsParity(4)
The memory array ECC type is
parity.
memoryArrayECCTypeIsSingleBitECC(5) The memory array ECC type is
Correctable Memory Event ECC.
memoryArrayECCTypeIsMultiBitECC(6)
The memory array ECC type is
Uncorrectable Memory Event
ECC.
memoryArrayECCTypeIsCRC(7)
The memory array ECC type is
CRC.
Table 15-3. Physical Memory Configuration State Capabilities
Variable Name: DellPhysicalMemoryConfigStateCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
If set to 0 (zero)
There are no state capabilities.
unknownCapabilities(1)
State capabilities are unknown.
enableCapable(2)
Object enable/disable is supported.
notReadyCapable(4)
Object not ready is supported.
386
Memory Group
book.book Page 387 Wednesday, March 6, 2013 12:37 AM
Table 15-4.
Physical Memory Configuration State Settings
Variable Name: DellPhysicalMemoryConfigStateSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
If set to 0 (zero)
There are no state settings.
unknown(1)
State settings are unknown.
enabled(2)
Object is disabled (offline) 0,
or enabled (online) 1.
notReady(4)
Object not ready.
redundantMemoryIsActive(8)
Redundant memory is active
(in use)
enabledAndRedundantMemoryIsActive(10) Redundant memory is
enabled and in use.
Table 15-5.
Physical Memory Configuration Redundant Capabilities
Variable Name:
DellPhysicalMemoryConfigRedundantCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
If set to 0 (zero)
There are no redundant memory capabilities.
unknownCapabilities(1)
Redundant capabilities are unknown.
The redundant capabilities are:
spareCapable(2)
Spare redundant memory feature is supported.
mirrorCapable(4)
Mirror redundant memory feature is supported.
spareAndMirrorCapable(6) Spare and mirror redundant memory features are
supported.
raidCapable(8)
Redundant Array of Independent disks (RAID)
redundant memory feature is supported.
dddcCapable(16)
DDDC redundancy is supported.
Memory Group
387
book.book Page 388 Wednesday, March 6, 2013 12:37 AM
Table 15-6. Physical Memory Configuration Redundant Settings
Variable Name:
DellPhysicalMemoryConfigRedundantSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
If set to 0 (zero)
There are no redundant memory settings enabled.
unknown(1)
Redundant settings are unknown.
The following redundant settings are mutually exclusive:
spareEnabled(2)
Spare redundant memory feature is enabled.
mirrorEnabled(4)
Mirror redundant memory feature is enabled.
raidEnabled(8)
RAID redundant memory feature is enabled.
dddcCapable(16)
DDDC redundancy is enabled.
Table 15-7. Physical Memory Logging Capabilities
Variable Name: DellPhysicalMemoryLoggingCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
If set to 0 (zero)
There are no logging capabilities.
unknown Capabilities(1)
Logging capabilities are unknown.
The logging capabilities are:
enableCapable(2)
388
Memory Group
Logging enable/disable using Simple Network
Management Protocol (SNMP) is supported.
book.book Page 389 Wednesday, March 6, 2013 12:37 AM
Table 15-8.
Physical Memory Logging Settings
Variable Name: DellPhysicalMemoryLoggingSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
If set to 0 (zero)
There are no logging settings enabled.
unknown Capabilities(1)
Logging capabilities are unknown.
The logging settings are:
enabled(2)
Logging is disabled (0), or enabled (1).
Memory Group
389
book.book Page 390 Wednesday, March 6, 2013 12:37 AM
390
Memory Group
book.book Page 391 Wednesday, March 6, 2013 12:37 AM
BIOS Setup Control Group
16
Basic Input/Output System (BIOS) Setup Control Group variables provide
information about the functions that the BIOS performs in your system.
This management information base (MIB) group includes variables for the
boot sequence, speakers, diskettes, ports, network interface controllers (NICs),
and the Wakeup on local area network (LAN) feature.
BIOS Setup Control Group Tables
The MIB tables in this group define the BIOS control of devices and
controller cards that are typically present in a system.
•
"BIOS Setup Control Table" on page 391
•
"SCSI Control Table" on page 402
•
"Parallel Port Control Table" on page 404
•
"Serial Port Control Table" on page 406
•
"USB Control Table" on page 408
•
"IDE Control Table" on page 410
•
"Diskette Control Table" on page 412
•
"Network Interface Control Table" on page 414
The following MIB table in the BIOS Setup Control Group is supported on
Dell PowerEdge xx2x (12G) systems:
•
"BIOS Setting Table" on page 417
BIOS Setup Control Table
Name
biosSetUpControlTable
Object ID
1.3.6.1.4.1.674.10892.1.1400.10
Description
Defines the set of single devices in a chassis controlled by the
BIOS.
Syntax
BiosSetUpControlTableEntry
BIOS Setup Control Group
391
book.book Page 392 Wednesday, March 6, 2013 12:37 AM
Name
biosSetUpControlTable
Access
Not accessible
BIOS Setup Control Table Entry
Name
biosSetUpControlTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1
Description
Defines the BIOS Control Device Table entry.
Syntax
BiosSetUpControlTableEntry
Access
Not accessible
Index
biosSetUpControlchassisIndex
BIOS Setup Control Chassis Index
Name
biosSetUpControlchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
BIOS Setup Control (BSUC) Pointing Device Control Capabilities
Name
bSUCpointingDeviceControlCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.2
Description
Defines the capabilities of the pointing device.
Syntax
DellStateCapabilities
Access
Read-only
BIOS Setup Control Pointing Device Control Settings
Name
bSUCpointingDeviceControlSettings
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.3
Description
Defines the state of the pointing device.
392
BIOS Setup Control Group
book.book Page 393 Wednesday, March 6, 2013 12:37 AM
Name
bSUCpointingDeviceControlSettings
Syntax
DellStateSettings
Access
Read-write
BIOS Setup Control Pointing Device Control Status
Name
bSUCpointingDeviceControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.4
Description
Defines the status of the pointing device.
Syntax
DellStatus
Access
Read-only
BIOS Setup Control Pointing Device Control Name
Name
bSUCpointingDeviceControlName
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.5
Description
Defines the setup BIOS name of the pointing device.
Syntax
DellString
Access
Read-only
BIOS Setup Control Numeric Lock Control Capabilities
Name
bSUCnumLockControlCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.6
Description
Defines the capabilities of the numeric lock.
Syntax
DellStateCapabilities
Access
Read-only
BIOS Setup Control Numeric Lock Control Settings
Name
bSUCnumLockControlSettings
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.7
Description
Defines the state of the numeric lock.
BIOS Setup Control Group
393
book.book Page 394 Wednesday, March 6, 2013 12:37 AM
Name
bSUCnumLockControlSettings
Syntax
DellStateSettings
Access
Read-only
BIOS Setup Control Numeric Lock Control Status
Name
bSUCnumLockControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.8
Description
Defines the status of the numeric lock.
Syntax
DellStatus
Access
Read-only
BIOS Setup Control Numeric Lock Control Name
Name
bSUCnumLockControlName
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.9
Description
Defines the setup BIOS name of the numeric lock.
Syntax
DellString
Access
Read-only
BIOS Setup Control Processor Serial Number Control Capabilities
Name
bSUCprocessorSerialNumberControlCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.10
Description
Defines if the processor serial number can be returned.
Syntax
DellStateCapabilities
Access
Read-only
BIOS Setup Control Processor Serial Number Control Settings
Name
bSUCprocessorSerialNumberControlSettings
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.11
Description
Defines the state of the processor serial number.
394
BIOS Setup Control Group
book.book Page 395 Wednesday, March 6, 2013 12:37 AM
Name
bSUCprocessorSerialNumberControlSettings
Syntax
DellStateSettings
Access
Read-only
BIOS Setup Control Processor Serial Number Control Status
Name
bSUCprocessorSerialNumberControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.12
Description
Defines the status of the processor serial number.
Syntax
DellStatus
Access
Read-only
BIOS Setup Control Processor Serial Number Control Name
Name
bSUCprocessorSerialNumberControlName
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.13
Description
Defines the setup BIOS name of the processor serial number.
Syntax
DellString
Access
Read-write
BIOS Setup Control Speaker Control Capabilities Unique
Name
bSUCspeakerControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.14
Description
Defines the capabilities of the speaker control.
Syntax
DellSpeakerControlCapabilitiesUnique (See Table 16-1)
Access
Read-only
BIOS Setup Control Speaker Control Settings Unique
Name
bSUCspeakerControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.15
Description
Defines the settings available for speaker control.
BIOS Setup Control Group
395
book.book Page 396 Wednesday, March 6, 2013 12:37 AM
Name
bSUCspeakerControlSettingsUnique
Syntax
DellSpeakerControlSettingsUnique (See Table 16-2)
Access
Read-only
BIOS Setup Control Speaker Control Status
Name
bSUCspeakerControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.16
Description
Defines the status of speaker control.
Syntax
DellStatus
Access
Read-only
BIOS Setup Control Speaker Control Name
Name
bSUCspeakerControlName
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.17
Description
Defines the setup BIOS name of the speaker control.
Syntax
DellString
Access
Read-only
BIOS Setup Control NIF Wakeup on LAN Control Capabilities Unique
Name
bSUCnIFwakeonLanControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.18
Description
Defines the defines the capabilities of the network interface
function (NIF) Wakeup on LAN.
Syntax
DellNIFwakeonLanControlCapabilitiesUnique (See Table 16-4)
Access
Read-only
BIOS Setup Control NIF Wakeup on LAN Control Settings Unique
Name
bSUCnIFwakeonLanControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.19
396
BIOS Setup Control Group
book.book Page 397 Wednesday, March 6, 2013 12:37 AM
Name
bSUCnIFwakeonLanControlSettingsUnique
Description
Defines the state of the NIF Wakeup on LAN.
Syntax
DellNIFwakeonLanControlSettingsUnique (See Table 16-4)
Access
Read-only
BIOS Setup Control NIF Wakeup on LAN Control Status
Name
bSUCnIFwakeonLanControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.20
Description
Defines the status of the NIF Wakeup on LAN.
Syntax
DellStatus
Access
Read-only
BIOS Setup Control NIF Wakeup on LAN Control Name
Name
bSUCnIFwakeonLanControlName
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.21
Description
Defines the setup BIOS name of the NIF Wakeup on LAN.
Syntax
DellString
Access
Read-only
BIOS Setup Control Boot Sequence Control Capabilities Unique
Name
bSUCbootSequenceControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.22
Description
Defines the capabilities of the boot sequence.
Syntax
DellBootSequenceControlCapabilitiesUnique (See Table 16-5)
Access
Read-only
BIOS Setup Control Boot Sequence Control Settings Unique
Name
DellBootSequenceControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.23
BIOS Setup Control Group
397
book.book Page 398 Wednesday, March 6, 2013 12:37 AM
Name
DellBootSequenceControlSettingsUnique
Description
Defines the state of the boot sequence.
Syntax
DellBootSequenceControlSettingsUnique (See Table 16-6)
Access
Read-only
BIOS Setup Control Boot Sequence Control Status
Name
bSUCbootSequenceControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.24
Description
Defines the status of the boot sequence.
Syntax
DellStatus
Access
Read-only
BIOS Setup Control Boot Sequence Control Name
Name
bSUCbootSequenceControlName
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.25
Description
Defines the control name of the boot sequence.
Syntax
DellString
Access
Read-only
BIOS Setup Control Administrator Password Control Capabilities Unique
Name
bSUCadministratorPasswordControlCapabilities
Unique
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.26
Description
Defines the capabilities of the administrator password control.
Syntax
DellBIOSPasswordControlCapabilitiesUnique
Access
Read-only
398
BIOS Setup Control Group
book.book Page 399 Wednesday, March 6, 2013 12:37 AM
BIOS Setup Control Administrator Password Control Settings Unique
Name
bSUCadministratorPasswordControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.27
Description
Defines the settings for administrator password control.
Syntax
DellBIOSPasswordControlSettingsUnique (See Table 16-9)
Access
Read-write
BIOS Setup Control Administrator Password Control Status
Name
bSUCadministratorPasswordControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.28
Description
Defines the status for administrator password control.
Syntax
DellStatus
Access
Read-only
BIOS Setup Control Administrator Password Verify Name
Name
bSUCadministratorPasswordVerifyName
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.29
Description
Defines the setup BIOS name for the current administrator password.
Syntax
DellString
Access
Read-write
BIOS Setup Control Administrator Password New Password Name
Name
bSUCadministratorPasswordNewPasswordName
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.30
Description
Defines the setup BIOS name of the new administrator
password. To set a new administrator password, you must have
successfully set the current administrator password immediately
preceding this password change.
Syntax
DellString
Access
Read-write
BIOS Setup Control Group
399
book.book Page 400 Wednesday, March 6, 2013 12:37 AM
BIOS Setup Control User Password Control Capabilities Unique
Name
bSUCuserPasswordControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.31
Description
Defines the capabilities of user password control.
Syntax
DellBIOSPasswordControlCapabilitiesUnique
Access
Read-only
BIOS Setup Control User Password Control Settings Unique
Name
bSUCuserPasswordControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.32
Description
Defines the control settings for user password control.
Syntax
DellBIOSPasswordControlSettingsUnique (See Table 16-9)
Access
Read-write
BIOS Setup Control User Password Control Status
Name
bSUCuserPasswordControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.33
Description
Defines the status of the user password control.
Syntax
DellStatus
Access
Read-only
BIOS Setup Control User Password Verify Name
Name
bSUCuserPasswordVerifyName
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.34
Description
Defines the setup BIOS name of the current user password.
Syntax
DellString
Access
Read-write
400
BIOS Setup Control Group
book.book Page 401 Wednesday, March 6, 2013 12:37 AM
BIOS Setup Control User Password New Password Name
Name
bSUCuserPasswordNewPasswordName
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.35
Description
Defines the setup BIOS name of the new user password. To set a
new user password, a you must have successfully set the current
user password immediately preceding this password change.
Syntax
DellString
Access
Read-write
BIOS Setup Control TPM Security Control Capabilities
Name
bSUCtpmSecurityControlCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.36
Description
Defines the BIOS setup control capabilities of Trusted Platform
Module (TPM) security.
Syntax
DellTPMSecurityControlCapabilities
Access
Read-only
BIOS Setup Control TPM Security Control Setting
Name
bSUCtpmSecurityControlSetting
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.37
Description
Defines the BIOS setup control setting of Trusted Platform
Module (TPM) security.
Syntax
DellTPMSecurityControlSetting
Access
Read-only
BIOS Setup Control TPM Security Control Status
Name
bSUCtpmSecurityControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.38
Description
Defines the BIOS setup control status of Trusted Platform
Module (TPM) security.
Syntax
DellStatus
Access
Read-only
BIOS Setup Control Group
401
book.book Page 402 Wednesday, March 6, 2013 12:37 AM
BIOS Setup Control TPM Security Control Name
Name
bSUCtpmSecurityControlName
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.39
Description
Defines the BIOS setup control name of Trusted Platform
Module (TPM) security.
Syntax
DellString
Access
Read-only
SCSI Control Table
Name
sCSIControlTable
Object ID
1.3.6.1.4.1.674.10892.1.1400.20
Description
Defines the Small Computer System Interface (SCSI) Control Table.
Syntax
SCSIControlTableEntry
Access
Not accessible
SCSI Control Table Entry
Name
sCSIControlTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1400.20.1
Description
Defines the SCSI Control Table entry.
Syntax
SCSIControlTableEntry
Access
Not accessible
Index
sCSIControlchassisIndex, sCSIControlIndex
SCSI Control Chassis Index
Name
sCSIControlchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.20.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
402
BIOS Setup Control Group
book.book Page 403 Wednesday, March 6, 2013 12:37 AM
SCSI Control Index
Name
sCSIControlIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.20.1.2
Description
Defines the index (one-based) of the SCSI controller in this chassis.
Syntax
DellObjectRange
Access
Read-only
SCSI Control Capabilities
Name
sCSIControlCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1400.20.1.3
Description
Defines the capabilities of the SCSI controller.
Syntax
DellStateCapabilities
Access
Read-only
SCSI Control Settings
Name
sCSIControlSettings
Object ID
1.3.6.1.4.1.674.10892.1.1400.20.1.4
Description
Defines the state of the SCSI controller.
Syntax
DellStateSettings
Access
Read-only
SCSI Control Status
Name
sCSIControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.20.1.5
Description
Defines the status of the SCSI controller.
Syntax
DellStatus
Access
Read-only
BIOS Setup Control Group
403
book.book Page 404 Wednesday, March 6, 2013 12:37 AM
SCSI Control Name
Name
sCSIControlName
Object ID
1.3.6.1.4.1.674.10892.1.1400.20.1.6
Description
Defines the setup BIOS name of the SCSI controller.
Syntax
DellString
Access
Read-only
Parallel Port Control Table
Name
parallelPortControlTable
Object ID
1.3.6.1.4.1.674.10892.1.1400.30
Description
Defines the Parallel Port Control Table.
Syntax
ParallelPortControlTableEntry
Access
Not accessible
Parallel Port Control Table Entry
Name
parallelPortControlTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1400.30.1
Description
Defines the Parallel Port Control Table entry.
Syntax
ParallelPortControlTableEntry
Access
Not accessible
Index
parallelPortControlchassisIndex, parallelPortControlIndex
Parallel Port Control Chassis Index
Name
parallelPortControlchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.30.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
404
BIOS Setup Control Group
book.book Page 405 Wednesday, March 6, 2013 12:37 AM
Parallel Port Control Index
Name
parallelPortControlIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.30.1.2
Description
Defines the index (one-based) of the parallel port in this chassis.
Syntax
DellObjectRange
Access
Read-only
Parallel Port Control Capabilities Unique
Name
parallelPortControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.30.1.3
Description
Defines the capabilities of the parallel port.
Syntax
DellParallelPortControlCapabilitiesUnique (See Table 16-12)
Access
Read-only
Parallel Port Control Settings Unique
Name
parallelPortControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.30.1.4
Description
Defines the state of the parallel port.
Syntax
DellParallelPortControlSettingsUnique (See Table 16-13)
Access
Read-only
Parallel Port Control Status
Name
parallelPortControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.30.1.5
Description
Defines the status of the parallel port.
Syntax
DellStatus
Access
Read-only
BIOS Setup Control Group
405
book.book Page 406 Wednesday, March 6, 2013 12:37 AM
Parallel Port Control Name
Name
parallelPortControlName
Object ID
1.3.6.1.4.1.674.10892.1.1400.30.1.6
Description
Defines the setup BIOS name of the parallel port.
Syntax
DellString
Access
Read-only
Parallel Port Control Mode Capabilities Unique
Name
parallelPortControlModeCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.30.1.7
Description
Defines the mode capabilities of the parallel port.
Syntax
DellParallelPortControlModeCapabilitiesUnique (See Table 16-14)
Access
Read-only
Parallel Port Control Mode Settings Unique
Name
parallelPortControlModeSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.30.1.8
Description
Defines the mode settings of the parallel port.
Syntax
DellParallelPortControlModeSettingsUnique (See Table 16-14)
Access
Read-write
Serial Port Control Table
Name
serialPortControlTable
Object ID
1.3.6.1.4.1.674.10892.1.1400.40
Description
Defines the Serial Port Control Table.
Syntax
SerialPortControlTableEntry
Access
Not accessible
406
BIOS Setup Control Group
book.book Page 407 Wednesday, March 6, 2013 12:37 AM
Serial Port Control Table Entry
Name
serialPortControlTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1400.40.1
Description
Defines the Serial Port Control Table entry.
Syntax
SerialPortControlTableEntry
Access
Not accessible
Index
serialPortControlchassisIndex, serialPortControlIndex
Serial Port Control Chassis Index
Name
serialPortControlchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.40.1.1
Description
Defines index (one-based) of this chassis.
Syntax
DellObjectRange
Access
read-only
Serial Port Control Index
Name
serialPortControlIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.40.1.2
Description
Defines the index (one-based) of the serial port in this chassis.
Syntax
DellObjectRange
Access
read-only
Serial Port Control Capabilities Unique
Name
serialPortControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.40.1.3
Description
Defines the capabilities of the serial port.
Syntax
DellSerialPortControlCapabilitiesUnique (See Table 16-15)
Access
Read-only
BIOS Setup Control Group
407
book.book Page 408 Wednesday, March 6, 2013 12:37 AM
Serial Port Control Settings Unique
Name
serialPortControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.40.1.4
Description
Defines the settings of the serial port.
Syntax
DellSerialPortControlSettingsUnique (See Table 16-16)
Access
Read-only
Serial Port Control Status
Name
serialPortControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.40.1.5
Description
Defines the status of the serial port.
Syntax
DellStatus
Access
Read-only
Serial Port Control Name
Name
serialPortControlName
Object ID
1.3.6.1.4.1.674.10892.1.1400.40.1.6
Description
Defines the setup BIOS name of the serial port.
Syntax
DellString
Access
Read-only
USB Control Table
These objects enable you to track the attributes of your Universal Serial Bus (USB).
Name
usbControlTable
Object ID
1.3.6.1.4.1.674.10892.1.1400.50
Description
Defines the USB Table.
Syntax
UsbControlTableEntry
Access
Not accessible
408
BIOS Setup Control Group
book.book Page 409 Wednesday, March 6, 2013 12:37 AM
USB Control Table Entry
Name
usbControlTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1400.50.1
Description
Defines the USB Table entry.
Syntax
UsbControlTableEntry
Access
Not accessible
Index
usbControlchassisIndex, usbControlIndex
USB Control Chassis Index
Name
usbControlchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.50.1.1
Description
Defines index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
USB Control Index
Name
usbControlIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.50.1.2
Description
Defines the index (one-based) of the USB in this chassis.
Syntax
DellObjectRange
Access
Read-only
USB Control Capabilities
Name
usbControlCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1400.50.1.3
Description
Defines the capabilities of the USB.
Syntax
DellStateCapabilities
Access
Read-only
BIOS Setup Control Group
409
book.book Page 410 Wednesday, March 6, 2013 12:37 AM
USB Control Settings
Name
usbControlSettings
Object ID
1.3.6.1.4.1.674.10892.1.1400.50.1.4
Description
Defines the control settings for the USB.
Syntax
DellStateSettings
Access
Read-only
USB Control Status
Name
usbControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.50.1.5
Description
Defines the status of the USB.
Syntax
DellStatus
Access
Read-only
USB Control Name
Name
usbControlName
Object ID
1.3.6.1.4.1.674.10892.1.1400.50.1.6
Description
Defines the setup BIOS name of the USB.
Syntax
DellString
Access
Read-only
IDE Control Table
These objects enable you to track the attributes of Integrated Device
Electronics (IDE) controller cards in your system.
Name
ideControlTable
Object ID
1.3.6.1.4.1.674.10892.1.1400.60
Description
Defines the IDE Control Table.
Syntax
IdeControlTableEntry
Access
Not accessible
410
BIOS Setup Control Group
book.book Page 411 Wednesday, March 6, 2013 12:37 AM
IDE Control Table Entry
Name
ideControlTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1400.60.1
Description
Defines the IDE Control Table entry.
Syntax
IdeControlTableEntry
Access
Not accessible
Index
ideControlchassisIndex, ideControlIndex
IDE Control Chassis Index
Name
ideControlchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.60.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
IDE Control Index
Name
ideControlIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.60.1.2
Description
Defines the index (one-based) of the IDE controller in this chassis.
Syntax
DellObjectRange
Access
Read-only
IDE Control Capabilities Unique
Name
ideControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.60.1.3
Description
Defines the capabilities of the IDE controller.
Syntax
DellideControlCapabilitiesUnique (See Table 16-17)
Access
Read-only
BIOS Setup Control Group
411
book.book Page 412 Wednesday, March 6, 2013 12:37 AM
IDE Control Settings Unique
Name
ideControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.60.1.4
Description
Defines the settings for the IDE controller.
Syntax
DellideControlCapabilitiesUnique (See Table 16-17)
Access
Read-only
IDE Control Status
Name
ideControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.60.1.5
Description
Defines the status for the IDE controller.
Syntax
DellStatus
Access
Read-only
IDE Control Name
Name
ideControlName
Object ID
1.3.6.1.4.1.674.10892.1.1400.60.1.6
Description
Defines the setup BIOS name for the IDE controller.
Syntax
DellStatus
Access
Read-only
Diskette Control Table
Name
disketteControlTable
Object ID
1.3.6.1.4.1.674.10892.1.1400.70
Description
Defines the Diskette Control Table.
Syntax
DisketteControlTableEntry
Access
Not accessible
412
BIOS Setup Control Group
book.book Page 413 Wednesday, March 6, 2013 12:37 AM
Diskette Control Table Entry
Name
disketteControlTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1400.70.1
Description
Defines the Diskette Control Table entry.
Syntax
DellStatus
Access
Not accessible
Index
disketteControlchassisIndex, disketteControlIndex
Diskette Control Chassis Index
Name
disketteControlchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.70.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Diskette Control Index
Name
disketteControlIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.70.1.2
Description
Defines the index of the diskette controllers in this chassis.
Syntax
DellObjectRange
Access
Read-only
Diskette Control Capabilities Unique
Name
disketteControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.70.1.3
Description
Defines the capabilities of the diskette controller.
Syntax
DellDisketteControlCapabilitiesUnique (See Table 16-18)
Access
Read-only
BIOS Setup Control Group
413
book.book Page 414 Wednesday, March 6, 2013 12:37 AM
Diskette Control Settings Unique
Name
disketteControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.70.1.4
Description
Defines the control settings for the diskette controller.
Syntax
DellDisketteControlSettingsUnique
Access
Read-only
Diskette Control Status
Name
disketteControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.70.1.5
Description
Defines the status of the diskette controller.
Syntax
DellStatus
Access
Read-only
Diskette Control Name
Name
disketteControlName
Object ID
1.3.6.1.4.1.674.10892.1.1400.70.1.6
Description
Defines the setup BIOS name of the diskette controller.
Syntax
DellString
Access
Read-only
Network Interface Control Table
These MIB objects enable you to track the attributes of the NIC card for your
system.
Name
networkInterfaceControlTable
Object ID
1.3.6.1.4.1.674.10892.1.1400.80
Description
Defines the Network Interface Control Table.
Syntax
NetworkInterfaceControlTableEntry
Access
Not accessible
414
BIOS Setup Control Group
book.book Page 415 Wednesday, March 6, 2013 12:37 AM
Network Interface Control Table Entry
Name
networkInterfaceControlTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1400.80.1
Description
Defines the Network Interface Control Table entry.
Syntax
NetworkInterfaceControlTableEntry
Access
Not accessible
Index
networkInterfaceControlchassisIndex,
networkInterfaceControlIndex
Network Interface Control Chassis Index
Name
networkInterfaceControlchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.80.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Network Interface Control Index
Name
networkInterfaceControlIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.80.1.2
Description
Defines the index (one-based) of the network interface
controller in this chassis.
Syntax
DellObjectRange
Access
Read-only
BIOS Setup Control Group
415
book.book Page 416 Wednesday, March 6, 2013 12:37 AM
Network Interface Control Capabilities Unique
Name
networkInterfaceControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.80.1.3
Description
Defines the capabilities of the NIC.
Syntax
DellNetworkInterfaceControlCapabilitiesUnique (See Table 16-19)
Access
Read-only
Network Interface Control Settings Unique
Name
networkInterfaceControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.80.1.4
Description
Defines the control settings for the NIC.
Syntax
DellNetworkInterfaceControlSettingsUnique (See Table 16-20)
Access
Read-write
Network Interface Control Status
Name
networkInterfaceControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.80.1.5
Description
Defines the status of the NIC.
Syntax
DellStatus
Access
Read-only
Network Interface Control Name
Name
networkInterfaceControlName
Object ID
1.3.6.1.4.1.674.10892.1.1400.80.1.6
Description
Defines the setup BIOS name of the NIC.
Syntax
DellString
Access
Read-only
416
BIOS Setup Control Group
book.book Page 417 Wednesday, March 6, 2013 12:37 AM
BIOS Setting Table
These MIB objects enable you to track the BIOS settings for your system.
NOTE: These MIB objects are supported on Dell PowerEdge xx2x systems.
Name
biosSettingTable
Object ID
1.3.6.1.4.1.674.10892.1.1400.90
Description
Defines the BIOS Setting Table.
Syntax
SEQUENCE OF BiosSettingTableEntry
Access
Not accessible
BIOS Setting Table Entry
Name
biosSettingTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1400.90.1
Description
Defines the BIOS Setting Table Entry.
Syntax
BiosSettingTableEntry
Access
Not accessible
Index
biosSettingChassisIndex,
biosSettingIndex
BIOS Setting Chassis Index
Name
biosSettingChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.90.1.1
Description
Defines the index (one based) of the associated chassis.
Syntax
DellObjectRange
Access
Read-only
BIOS Setting Index
Name
biosSettingIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.90.1.2
BIOS Setup Control Group
417
book.book Page 418 Wednesday, March 6, 2013 12:37 AM
Description
Defines the index (one based) of the BIOS setting.
Syntax
DellObjectRange
Access
Read-only
BIOS Setting Name
Name
biosSettingName
Object ID
1.3.6.1.4.1.674.10892.1.1400.90.1.3
Description
Defines the name of the BIOS setting.
Syntax
DisplayString
Access
Read-only
BIOS Setting Display Name
Name
biosSettingDisplayName
Object ID
1.3.6.1.4.1.674.10892.1.1400.90.1.4
Description
Defines the display name of the BIOS setting.
Syntax
DisplayString
Access
Read-only
BIOS Setting Value Type
Name
biosSettingValueType
Object ID
1.3.6.1.4.1.674.10892.1.1400.90.1.5
Description
Defines the type of the BIOS setting value.
Syntax
DellBIOSSettingValueType
Access
Read-only
BIOS Setting Current Value
Name
biosSettingCurrentValue
Object ID
1.3.6.1.4.1.674.10892.1.1400.90.1.6
Description
Defines the current value of the BIOS setting.
418
BIOS Setup Control Group
book.book Page 419 Wednesday, March 6, 2013 12:37 AM
Syntax
DisplayString
Access
Read-only
BIOS Setting Pending Value
Name
biosSettingPendingValue
Object ID
1.3.6.1.4.1.674.10892.1.1400.90.1.7
Description
Defines the pending value of the BIOS setting.
Syntax
DisplayString
Access
Read-only
BIOS Setting Default Value
Name
biosSettingDefaultValue
Object ID
1.3.6.1.4.1.674.10892.1.1400.90.1.8
Description
Defines the default value of the BIOS setting.
Syntax
DisplayString
Access
Read-only
BIOS Setting Possible Values
Name
biosSettingPossibleValues
Object ID
1.3.6.1.4.1.674.10892.1.1400.90.1.9
Description
Defines the possible values of the BIOS setting.
Syntax
DisplayString
Access
Read-only
BIOS Setting Display Order
Name
biosSettingDisplayOrder
Object ID
1.3.6.1.4.1.674.10892.1.1400.90.1.10
Description
Defines the recommended display order of the BIOS setting
within its BIOS setting group.
BIOS Setup Control Group
419
book.book Page 420 Wednesday, March 6, 2013 12:37 AM
Syntax
DellUnsigned32BitRange
Access
Read-only
BIOS Setting Group Display Name
Name
biosSettingGroupDisplayName
Object ID
1.3.6.1.4.1.674.10892.1.1400.90.1.11
Description
Defines the display name of the BIOS setting group for the
BIOS setting.
Syntax
DisplayString
Access
Read-only
BIOS Setting FQDD
Name
biosSettingFQDD
Object ID
1.3.6.1.4.1.674.10892.1.1400.90.1.12
Description
Fully Qualified Device Descriptor (FQDD) for the BIOS setting.
Syntax
DisplayString
Access
Read-only
BIOS Group Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 16-1. Speaker Control Capabilities Unique
Variable Name: DellSpeakerControlCapabilitiesUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
Speaker control capabilities are unknown.
enableCapable(2)
Setup BIOS can enable speaker control.
lowCapable(4)
Setup BIOS can set the speaker volume to low.
mediumCapable(8)
Setup BIOS can set the speaker volume to medium.
420
BIOS Setup Control Group
book.book Page 421 Wednesday, March 6, 2013 12:37 AM
Table 16-1.
Speaker Control Capabilities Unique (continued)
Variable Name: DellSpeakerControlCapabilitiesUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
highCapable(16)
Setup BIOS can set the speaker volume to high.
allVolumeCapable(30)
Setup BIOS can set the speaker volume to any of the
three settings.
Table 16-2.
Speaker Control Settings Unique
Variable Name: DellSpeakerControlSettingsUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
Speaker control state is unknown.
enabled(2)
Speaker control is enabled.
low(4)
Speaker control volume is low.
medium(8)
Speaker control volume is medium.
high(16)
Speaker control volume is high.
Table 16-3.
Network Interface (NIF) Wakeup on LAN Capabilities Unique
Variable Name: DellNIFwakeonLanControlCapabilitiesUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
Setup BIOS Wakeup on LAN
capabilities are unknown.
enableCapable(2)
Setup BIOS is capable of enabling the
NIF Wakeup on LAN.
addInCardCapable(4)
Setup BIOS is capable of enabling
Wakeup on LAN by option card.
onBoardCapable(8)
Setup BIOS is capable of enabling
Wakeup on LAN by integrated NIF.
BIOS Setup Control Group
421
book.book Page 422 Wednesday, March 6, 2013 12:37 AM
Table 16-3. Network Interface (NIF) Wakeup on LAN Capabilities Unique (continued)
Variable Name: DellNIFwakeonLanControlCapabilitiesUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
bothCapable(14)
Setup BIOS is capable of enabling
Wakeup on LAN by either option card or
integrated NIF.
Table 16-4. NIF Wakeup on LAN Control Settings Unique
Variable Name: DellNIFwakeonLanControlSettingsUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
NIF Wakeup on LAN state is unknown.
enabled(2)
NIF Wakeup on LAN is enabled.
addInCard(4)
NIF Wakeup on LAN is by option card.
onBoard(8)
NIF Wakeup on LAN is by integrated NIF.
addInCardOrOnBoard(12)
NIF Wakeup on LAN is by option card or
integrated NIF.
Table 16-5. Boot Sequence Control Capabilities Unique
Variable Name: DellBootSequenceControlCapabilitiesUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
bootSequenceUnknown(1)
Boot sequence capabilities are unknown.
bootFromDisketteFirstCapable Setup BIOS can boot from a diskette
(2)
first.
bootFromhardDriveFirstCapable Setup BIOS can boot from an IDE hard
(4)
drive first.
bootFromDisketteORHardDrive Setup BIOS can boot from a diskette or
FirstCapable(6)
an IDE hard drive first.
422
BIOS Setup Control Group
book.book Page 423 Wednesday, March 6, 2013 12:37 AM
Table 16-5.
Boot Sequence Control Capabilities Unique (continued)
Variable Name: DellBootSequenceControlCapabilitiesUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
bootFromDeviceListCapable(8) Setup BIOS can boot from a device list.
bootFromCDROMFirstCapable(16) Setup BIOS can boot from a CD first.
allFirstCapable(30)
Table 16-6.
Setup BIOS can boot by any of the
preceding methods first.
Boot Sequence Control Settings Unique
Variable Name: DellBootSequenceControlSettingsUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
bootSequenceUnknown(1)
Boot sequence state is unknown.
bootFromDisketteFirst(2)
Setup BIOS is set to boot by
diskette first.
bootFromHardDriveFirst(4)
Setup BIOS is set to boot by IDE
hard drive first.
bootFromDeviceList(8)
Setup BIOS is set to boot by a
device list.
bootFromCDROMFirst(16)
Setup BIOS is set to boot by CD
first.
Table 16-7.
BIOS Password Control Capabilities
Variable Name: DellBIOSPasswordControlCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
passwordControlCapabilitiesUn BIOS password capabilities are
known(1)
unknown.
passwordControlEnableCapable
(2)
Setup BIOS is capable of enabling
password changes.
BIOS Setup Control Group
423
book.book Page 424 Wednesday, March 6, 2013 12:37 AM
Table 16-7. BIOS Password Control Capabilities (continued)
Variable Name: DellBIOSPasswordControlCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
passwordControlJumperDisable
Capable(4)
Setup BIOS is capable of
determining if password control can
be jumper disabled.
passwordControlEnableANDJumper Setup BIOS is capable of enabling
DisableCapable(6)
password changes and of
determining if password control can
be jumper disabled.
Table 16-8. BIOS Password Control Settings Unique
Variable Name: DellBIOSPasswordControlSettingsUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
passwordControlSettingsUnknown(1) Setup BIOS password state is
unknown.
passwordControlEnabled(2)
Setup BIOS has password changes
enabled.
passwordControlJumperDisabled(4)
Setup BIOS has determined that
password control has been disabled
by a jumper.
Table 16-9. BIOS Password Control Settings
Variable Name: DellBIOSPasswordControlSettingsUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
passwordControlSettingsUnknown(1) Setup BIOS password state is
unknown.
passwordControlEnabled(2)
424
BIOS Setup Control Group
Setup BIOS has password changes
enabled.
book.book Page 425 Wednesday, March 6, 2013 12:37 AM
Table 16-9.
BIOS Password Control Settings (continued)
Variable Name: DellBIOSPasswordControlSettingsUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
passwordControlJumperDisabled(4)
Setup BIOS has determined that
password control has been
disabled by a jumper.
Table 16-10. TPM Security Control Capabilities
Variable Name: DellTPMSecurityControlCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
offCapable(1)
TPM security can be Off.
onWithPrebootMeasurementsCap TPM security can be On with Pre-boot
able(2)
Measurements.
onWithoutPrebootMeasurements TPM security can be On without Pre-boot
Capable(4)
Measurements.
Table 16-11. TPM Security Control Setting
Variable Name: DellTPMSecurityControlSetting
Data Type: Integer
Possible Data Values
Meaning of Data Value
off(0)
TPM security is Off.
onWithPrebootMeasurements(1) TPM security is On with Pre-boot
Measurements.
onWithoutPrebootMeasurements TPM security is On without Pre-boot
(2)
Measurements.
BIOS Setup Control Group
425
book.book Page 426 Wednesday, March 6, 2013 12:37 AM
Table 16-12. Parallel Port Control Capabilities
Variable Name: DellParallelPortControlCapabilitiesUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
Setup BIOS parallel port capabilities
are unknown.
enableCapable(2)
Setup BIOS can enable the parallel port.
lpt1Capable(4)
Setup BIOS can support parallel port 1.
lpt1andEnableCapable(6)
Setup BIOS has enabled parallel port 1.
lpt2Capable(8)
Setup BIOS can support parallel port 2.
lpt2andEnableCapable(10)
Setup BIOS has enabled parallel port 2.
lpt3Capable(16)
Setup BIOS can support parallel port 3.
lpt3andEnableCapable(18)
Setup BIOS has enabled parallel port 3.
allParallelPortCapable(30)
Setup BIOS can support any of the three
parallel ports.
Table 16-13. Parallel Port Control Settings
Variable Name: DellParallelPortControlSettingsUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
Parallel port state is unknown.
enabled(2)
Setup BIOS has enabled the parallel port.
lpt1(4)
Setup BIOS supports parallel port 1.
lpt1Enabled(6)
Setup BIOS has enabled parallel port 1.
lpt2(8)
Setup BIOS supports parallel port 2.
lpt2Enabled(10)
Setup BIOS has enabled parallel port 2.
lpt3(16)
Setup BIOS supports parallel port 3.
426
BIOS Setup Control Group
book.book Page 427 Wednesday, March 6, 2013 12:37 AM
Table 16-14. Parallel Port Control Mode Settings
Variable Name: DellParallelPortControlModeSettingsUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
Parallel port mode is unknown.
atModeEnabled(2)
Setup BIOS has set the parallel port to AT mode.
ps2ModeEnabled(4)
Setup BIOS has set the parallel port to Personal
Systems/2 (PS/2) mode.
ecpModeEnabled(8)
Setup BIOS has set the parallel port to Extended
Capabilities Port (ECP) mode.
eppModeEnabled(16)
Setup BIOS has set the parallel port to Enhanced
Parallel Port (EPP) mode.
Table 16-15. Serial Port Control Capabilities
Variable Name: DellSerialPortControlCapabilitiesUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
Setup BIOS serial port capabilities are
unknown.
enableCapable(2)
Setup BIOS can enable the serial port.
com1Capable(4)
Setup BIOS can support serial port 1.
enableAndCom1Capable(6)
Setup BIOS can enable serial port 1.
com2Capable(8)
Setup BIOS can support serial port 2.
enableAndCom2Capable(10) Setup BIOS is capable of enabling serial port 2.
com3Capable(16)
Setup BIOS can support serial port 3.
enableAndCom3Capable(18) Setup BIOS is capable of enabling serial port 3.
com4Capable(32)
Setup BIOS can support serial port 4.
enableAndCom4Capable(34) Setup BIOS is capable of enabling serial port 4.
autoConfigCapable(64)
Setup BIOS is capable of autoconfiguring all
serial ports.
BIOS Setup Control Group
427
book.book Page 428 Wednesday, March 6, 2013 12:37 AM
Table 16-15. Serial Port Control Capabilities (continued)
Variable Name: DellSerialPortControlCapabilitiesUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
com1OrCom3CapableAndAuto Setup BIOS has enabled autoconfiguration of
ConfigCapable(86)
COM1 and COM3 serial ports.
com2OrCom4CapableAndAuto Setup BIOS has enabled autoconfiguration of
ConfigCapable(106)
COM2 and COM4 serial ports.
allcomCapable(126)
Setup BIOS is capable of enabling or
autoconfiguring all serial ports.
Table 16-16. Serial Port Control Settings
Variable Name: DellSerialPortControlSettingsUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
Serial port state is unknown.
enabled(2)
Setup BIOS has enabled the serial port.
com1(4)
Setup BIOS has selected serial port 1.
com1Enabled(6)
Setup BIOS has enabled serial port 1.
com2(8)
Setup BIOS has selected serial port 2.
com2Enabled(10)
Setup BIOS has enabled serial port 2.
com3(16)
Setup BIOS has selected serial port 3.
com3Enabled(18)
Setup BIOS has enabled serial port 3.
com4(32)
Setup BIOS has selected serial port 4.
com4Enabled(34)
Setup BIOS has enabled serial port 4.
comPortsAutoConfig(64)
Setup BIOS has selected autoconfiguration
of serial ports.
enabledAndAutoConfig(66) Setup BIOS has enabled autoconfiguration
of serial ports.
428
BIOS Setup Control Group
book.book Page 429 Wednesday, March 6, 2013 12:37 AM
Table 16-17. IDE Control Capabilities
Variable Name: DellideControlCapabilitiesUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
IDE control capabilities are unknown.
ideControlAutoConfigOrEnable IDE controller is autoconfigurable or
Capable(2)
enable capable.
Table 16-18. Diskette Control Settings
Variable Name: DellDisketteControlSettingsUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
Diskette control state is unknown.
disketteControlAutoConfigEnabled Diskette control is set as
OrEnabled(2)
autoconfigurable or enabled.
Table 16-19. Network Interface Control Capabilities
Variable Name:
DellNetworkInterfaceControlCapabilitiesUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
Unknown setup BIOS network interface
capabilities.
enableCapable(2)
Setup BIOS is capable of enabling the
network interface.
enableWithoutPXECapable(4)
Setup BIOS is capable of enabling the
NIF without Pre-boot eXecution
Environment (PXE).
BIOS Setup Control Group
429
book.book Page 430 Wednesday, March 6, 2013 12:37 AM
Table 16-20. Network Interface Control Settings
Variable Name: DellNetworkInterfaceControlSettingsUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
Network interface state is unknown.
enabled(2)
Network interface is enabled.
enabledWithoutPXE(4)
Network interface is enabled without PXE.
Table 16-21. BIOS Setting Value Type
Variable Name: DellBIOSSettingValueType
Data Type: Integer
Possible Data Values
Meaning of Data Value
integer(1)
Value type is integer.
string(2)
Value type is string.
enumeration(3)
Value type is enumeration.
orderedList(4)
Value type is ordered list.
430
BIOS Setup Control Group
book.book Page 431 Wednesday, March 6, 2013 12:37 AM
Local Response Agent Group
17
The Local Response Agent Group provides information about various
attributes of your system’s local response agent (LRA). The LRA allows
systems managers to predetermine how a system running the server
administrator responds to a particular event type, such as the loss of
redundancy in a specific component or the elevation of temperature in a
chassis. Systems managers can configure the LRA to respond to an event type
with a specific action. When the condition of the critical component worsens,
the systems manager can escalate the response to make it more obvious to the
operator.
For example, when a voltage probe on a monitored machine reaches a
warning condition, the systems manager may want to notify the operator by
causing the machine to beep. When the voltage probe reaches failure, the
systems manager might want to have the system that has a failing component
send a broadcast message to the management system and power off the
troubled system.
LRA Group Tables
The following management information base (MIB) tables define
LRA variable attributes:
•
"LRA Global Settings Table" on page 432
•
"LRA Action Table" on page 434
LRA Global Settings
The global settings table allows the systems manager to determine what
LRA capabilities exist for a specific system that is running Server Administrator.
Some machines may support all or some of the capabilities described in
DellLocalResponseAgentCapabilitiesUnique. The LRA Global Settings Table
also defines thermal shutdown capabilities and settings. In the event that a
temperature probe determines the temperature is at or over the failure limit,
the systems manager can set an action to be taken automatically.
Local Response Agent Group
431
book.book Page 432 Wednesday, March 6, 2013 12:37 AM
LRA Global Settings Table
Name
lRAGlobalSettingsTable
Object ID
1.3.6.1.4.1.674.10892.1.1500.10
Description
Defines the LRA Global Settings Table.
Syntax
SEQUENCE OF LRAGlobalSettingsTableEntry
Access
Not accessible
LRA Global Settings Table Entry
Name
lRAGlobalSettingsTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1500.10.1
Description
Defines the LRA Global Settings Table entry.
Syntax
LRAGlobalSettingsTableEntry
Access
Not accessible
Index
lRAGlobalchassisIndex
LRA Global Chassis Index
Name
lRAGlobalchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1500.10.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
LRA Global State
Name
lRAGlobalState
Object ID
1.3.6.1.4.1.674.10892.1.1500.10.1.2
Description
Defines the state of the LRA global settings.
Syntax
DellStateSettings
Access
Read-only
432
Local Response Agent Group
book.book Page 433 Wednesday, March 6, 2013 12:37 AM
LRA Global Settings Disable Time-out Value
Name
lRAGlobalSettingsDisableTimeoutValue
Object ID
1.3.6.1.4.1.674.10892.1.1500.10.1.3
Description
Defines the time-out duration countdown, in seconds, that the
LRA global settings are disabled after a system shutdown and reboot.
Syntax
DellUnsigned32BitRange
Access
Read-only
LRA Global Settings Capabilities Unique
Name
lRAGlobalSettingsCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1500.10.1.4
Description
Defines the set of global capabilities that all local response
agents may or may not allow to be set or reset.
Syntax
DellLocalResponseAgentCapabilitiesUnique (See Table 17-1)
Access
Read-only
LRA Global Thermal Shutdown Capabilities Unique
Name
lRAGlobalThermalShutdownCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1500.10.1.5
Description
Defines the set of thermal shutdown capabilities that are
supported by the LRA.
Syntax
DellLRAThermalShutdownCapabilitiesUnique
Access
Read-only
LRA Global Thermal Shutdown State Settings Unique
Name
lRAGlobalThermalShutdownStateSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1500.10.1.6
Description
Defines the set of thermal shutdown state and settings that the
local response agent supports.
Syntax
DellLRAThermalShutdownStateSettingsUnique
Access
Read-write
Local Response Agent Group
433
book.book Page 434 Wednesday, March 6, 2013 12:37 AM
LRA Action Table
The DellLocalResponseAgentCapabilitiesUnique variable in the
global action table defines the capabilities that are allowed for a particular
system. The LRA Action Table that follows selects which of the system’s
capabilities (global actions) are to be enabled.
Name
lRAActionTableTable
Object ID
1.3.6.1.4.1.674.10892.1.1500.20
Description
Defines the LRA Action Table.
Syntax
SEQUENCE OF LRAActionTableTableEntry
Access
Not accessible
LRA Action Table Entry
Name
lRAActionTableTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1500.20.1
Description
Defines the LRA Action Table entry.
Syntax
LRAActionTableTableEntry
Access
Not accessible
Index
lRAActionTablechassisIndex,
lRAActionTableActionNumberIndex
LRA Action Table Chassis Index
Name
lRAActionTablechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1500.20.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
434
Local Response Agent Group
book.book Page 435 Wednesday, March 6, 2013 12:37 AM
LRA Action Table Action Number Index
Name
lRAActionTableActionNumberIndex
Object ID
1.3.6.1.4.1.674.10892.1.1500.20.1.2
Description
Defines the LRA action number index. The action number indexes
are as follows:
• 160 — temperature failure action definition
• 168 — cooling device failure action definition
• 172 — voltage failure action definition
• 200 — temperature warning action definition
• 202 — voltage warning action definition
• 204 — cooling device warning action definition
• 206 — amperage failure action definition
• 208 — amperage warning action definition
• 210 — a power or cooling unit redundancy lost action definition
• 212 — a power or cooling unit redundancy degraded action definition
• 214 — power supply failed action definition
• 220 — chassis intrusion action definition
• 228 — memory device warning action definition
• 474 — memory device failure action definition
• 1006 — automatic system recovery (ASR) action definition
• 1353 — power supply warning action definition
• 1553 — log near full action definition
• 1554 — log full action definition
• 1603 — processor warning action definition
• 1604 — processor failure action definition
• 1703 — battery warning action definition
• 1704 — battery failure action definition
Syntax
DellUnsigned16BitRange
Access
Read-only
Local Response Agent Group
435
book.book Page 436 Wednesday, March 6, 2013 12:37 AM
LRA Action Table User Application Name
Name
lRAActionTableUserApplicationName
Object ID
1.3.6.1.4.1.674.10892.1.1500.20.1.3
Description
When the execute application value is set, provides the following
user-assignable LRA information:
• Name of the user application executable path
• File name to execute
Syntax
DisplayString (SIZE (0..256)
Access
Read-write
LRA Action Table Settings Unique
Name
lRAActionTableSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1500.20.1.4
Description
Defines the LRA settings.
Syntax
DellLocalResponseAgentSettingsUnique (See Table 17-3)
Access
Read-write
Local Response Agent Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 17-1. LRA Capabilities Definitions
Variable Name: DellLocalResponseAgentCapabilitiesUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
speakerControlCapable(1)
The LRA can issue a speaker beep.
consoleAlertCapable(2)
The LRA can alert the console.
broadcastMessageCapable(4)
The LRA can broadcast a message.
osShutDownCapable(8)
The LRA can shut down the operating
system.
436
Local Response Agent Group
book.book Page 437 Wednesday, March 6, 2013 12:37 AM
Table 17-1.
LRA Capabilities Definitions (continued)
Variable Name: DellLocalResponseAgentCapabilitiesUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
rebootCapable(16)
The LRA can reboot the system.
powerCycleCapable(32)
The LRA is capable of a system power
cycle.
powerOFFCapable(64)
The LRA can shut the system power off.
executeApplicationCapable(256) The LRA can execute a user mode
application.
lraFullyCapable(383)
Table 17-2.
The LRA has all of the preceding
capabilities.
LRA Thermal Shutdown Capabilities Unique
Variable Name: DellLRAThermalShutdownCapabilitiesUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The LRA has no thermal shutdown
capabilities.
Unknown capabilities(1)
The LRA’s thermal shutdown capabilities are
unknown.
enableCapable(2)
The LRA can be disabled (offline, a binary
0 value) or enabled (online, a binary 1 value).
warningCapable(4)
The LRA can carry out chassis-determined
action(s) when a warning condition is
detected.
enableOnWarningCapable(6) The LRA enables activation of chassisdetermined action(s) when a warning
condition is detected.
failureCapable(8)
The LRA can carry out chassis-determined
action(s) when a failure condition is detected.
Local Response Agent Group
437
book.book Page 438 Wednesday, March 6, 2013 12:37 AM
Table 17-2. LRA Thermal Shutdown Capabilities Unique (continued)
Variable Name: DellLRAThermalShutdownCapabilitiesUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
enableOnFailureCapable(10) The LRA enables activation of chassisdetermined action(s) when a failure condition
is detected.
The LRA enables activation of chassisdetermined action(s) when either a failure or a
warning condition is detected.
enableOnWarningOrFailure
Capable(14)
Table 17-3. Local Response Agent Settings Unique
Variable Name: DellLocalResponseAgentSettingsUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
speakerControl(1)
LRA is set to issue a speaker beep.
consoleAlert(2)
LRA is set to issue a console alert.
broadcastMessage(4)
LRA is set to issue a broadcast message.
osShutDown(8)
LRA is set to issue an operating system shutdown.
reboot(16)
LRA is set to issue a system reboot.
powerCycle(32)
LRA is set to issue a system power cycle.
powerOFF(64)
LRA is set to issue a system power off.
executeApplication(256)
LRA is set to start a user mode application.
allLRASettingsUnique(383) LRA is set to all LRA settings combinations.
438
Local Response Agent Group
book.book Page 439 Wednesday, March 6, 2013 12:37 AM
Cost of Ownership Group
18
The Cost of Ownership (COO) Group provides a full set of cost-tracking
objects, including fields for the computer’s manufacturer, insurer, lessor,
warranty, user, trouble tickets, and many others. You can use these management
information base (MIB) objects to obtain accurate and complete
measurements of the cost of each computer asset in your organization.
Cost of Ownership Group Tables
The Cost of Ownership Group defines objects in the following MIB tables:
•
"Cost of Ownership Table" on page 439
•
"COO Service Contract Table" on page 450
•
"COO Cost Event Log Table" on page 452
•
"COO Warranty Table" on page 454
•
"COO Lease Information Table" on page 456
•
"COO Schedule Number Table" on page 459
•
"COO Options Table" on page 460
•
"COO Maintenance Table" on page 462
•
"COO Repair Table" on page 464
•
"COO Support Information Table" on page 466
•
"COO Trouble Ticket Table" on page 468
Cost of Ownership Table
The following MIB object sets up the Cost of Ownership Table.
Name
cooTable
Object ID
1.3.6.1.4.1.674.10892.1.1600.10
Description
Defines the Cost of Ownership Table.
Syntax
SEQUENCE OF CooTableEntry
Access
Not accessible
Cost of Ownership Group
439
book.book Page 440 Wednesday, March 6, 2013 12:37 AM
Cost of Ownership Table Entry
Name
cooTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1
Description
Defines the Cost of Ownership Table entry.
Syntax
CooTableEntry
Access
Not accessible
Index
coochassisIndex
COO Chassis Index
Name
coochassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
CooTableEntry
Access
Read-only
COO State
Name
cooState
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.2
Description
Defines the acquisition state of the system.
Syntax
DellStateSettings
Access
Read-only
COO Acquisition Purchase Cost
Name
cooAquisitionPurchaseCost
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.3
Description
Defines the purchase cost of the system.
Syntax
DellUnsigned32BitRange
Access
Read-write
440
Cost of Ownership Group
book.book Page 441 Wednesday, March 6, 2013 12:37 AM
COO Acquisition Waybill Number
Name
cooAquisitionWayBillNumber
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.4
Description
Defines the waybill number of the system.
Syntax
DellUnsigned32BitRange
Access
Read-write
COO Acquisition Install Date Name
Name
cooAquisitionInstallDateName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.5
Description
Defines the installation date and time for the system.
Syntax
DellDateName
Access
Read-write
COO Acquisition Purchase Order
Name
cooAquisitionPurchaseOrder
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.6
Description
Defines the purchase order number of the system.
Syntax
DellUnsigned32BitRange
Access
Read-write
COO Acquisition Purchase Date Name
Name
cooAquisitionPurchaseDateName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.7
Description
Defines the purchase date and time of the system.
Syntax
DellDateName
Access
Read-write
Cost of Ownership Group
441
book.book Page 442 Wednesday, March 6, 2013 12:37 AM
COO Acquisition Signing Authority Name
Name
cooAquisitionSigningAuthorityName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.8
Description
Defines the name of the authorized person who signs for the
system.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Original Machine Configuration Expensed
Name
cooOriginalMachineConfigurationExpensed
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.9
Description
Specifies whether the purchase of this system was expensed.
Syntax
DellBoolean
Access
Read-write
COO Original Machine Configuration Vendor Name
Name
cooOriginalMachineConfigurationVendorName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.10
Description
Defines the vendor name of the system.
Syntax
DellCostofOwnershipString
Access
Read-only
COO Cost Center Information Vendor Name
Name
cooCostCenterInformationVendorName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.11
Description
Defines the cost center name of the system.
Syntax
DellCostofOwnershipString
Access
Read-write
442
Cost of Ownership Group
book.book Page 443 Wednesday, March 6, 2013 12:37 AM
COO User Information User Name
Name
cooUserInformationUserName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.12
Description
Defines the name of the user for this system.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Extended Warranty Start Date Name
Name
cooExtendedWarrantyStartDateName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.13
Description
Defines the extended warranty start date for this system.
Syntax
DellDateName
Access
Read-write
COO Extended Warranty End Date Name
Name
cooExtendedWarrantyEndDateName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.14
Description
Defines the extended warranty end date for this system.
Syntax
DellDateName
Access
Read-write
COO Extended Warranty Cost
Name
cooExtendedWarrantyCost
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.15
Description
Defines the extended warranty cost date for this system.
Syntax
DellUnsigned32BitRange
Access
Read-write
Cost of Ownership Group
443
book.book Page 444 Wednesday, March 6, 2013 12:37 AM
COO Extended Warranty Provider Name
Name
cooExtendedWarrantyProviderName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.16
Description
Defines the name of the extended warranty provider for this
system.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Ownership Code
Name
cooOwnershipCode
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.17
Description
Defines the ownership code for this system.
Syntax
DellCooOwnershipCodes (See Table 18-1)
Access
Read-write
COO Corporate Owner Name
Name
cooCorporateOwnerName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.18
Description
Defines the name of the corporation that owns this system.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Hazardous Waste Code Name
Name
cooHazardousWasteCodeName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.19
Description
Defines the hazardous waste code for this system.
Syntax
DellCostofOwnershipString
Access
Read-write
444
Cost of Ownership Group
book.book Page 445 Wednesday, March 6, 2013 12:37 AM
COO Deployment Date Length
Name
cooDeploymentDateLength
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.20
Description
Defines the deployment time for this system.
Syntax
DellUnsigned32BitRange
Access
Read-write
COO Deployment Duration Type
Name
cooDeploymentDurationType
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.21
Description
Defines the deployment time units for this system.
Syntax
DellCooHourDayDurationType (See Table 18-2)
Access
Read-write
COO Training Name
Name
cooTrainingName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.22
Description
Defines the training that the user has for this system.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Outsourcing Problem Description Name
Name
cooOutsourcingProblemDescriptionName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.23
Description
Defines a problem encountered with the outsourcing service
provider.
Syntax
DellCostofOwnershipString
Access
Read-write
Cost of Ownership Group
445
book.book Page 446 Wednesday, March 6, 2013 12:37 AM
COO Outsourcing Service Fee Name
Name
cooOutsourcingServiceFeeName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.24
Description
Defines amount that the outsourcing vendor charges for service.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Outsourcing Signing Authority Name
Name
cooOutsourcingSigningAuthorityName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.25
Description
Defines the name of the person who can sign the authorization for
service.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Outsourcing Provider Fee Name
Name
cooOutsourcingProviderFeeName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.26
Description
Defines any additional outsourcing charge for service.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Outsourcing Provider Service Level Name
Name
cooOutsourcingProviderServiceLevelName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.27
Description
Defines the service level agreement for the system.
Syntax
DellCostofOwnershipString
Access
Read-write
446
Cost of Ownership Group
book.book Page 447 Wednesday, March 6, 2013 12:37 AM
COO Insurance Company Name
Name
cooInsuranceCompanyName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.28
Description
Defines the name of the company that insures this system.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Box Asset Tag Name
Name
cooBoxAssetTagName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.29
Description
Defines the name of the asset tag.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Box System Name
Name
cooBoxSystemName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.30
Description
Defines the name of the system.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Box Central Processing Unit (CPU) Serial Number Name
Name
cooBoxCPUSerialNumberName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.31
Description
Defines the name of the CPU serial number for the system.
Syntax
DellCostofOwnershipString
Access
Read-write
Cost of Ownership Group
447
book.book Page 448 Wednesday, March 6, 2013 12:37 AM
COO Operating System Upgrade Type Name
Name
cooOperatingSystemUpgradeTypeName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.32
Description
Defines the name of the operating system on this system.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Operating System Upgrade Patch Level Name
Name
cooOperatingSystemUpgradePatchLevelName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.33
Description
Defines the name of the operating system patch level for this
system.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Operating System Upgrade Date
Name
cooOperatingSystemUpgradeDate
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.34
Description
Defines the upgrade file date for this operating system.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Depreciation Duration
Name
cooDepreciationDuration
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.35
Description
Defines the length of depreciation for this system.
Syntax
DellUnsigned32BitRange
Access
Read-write
448
Cost of Ownership Group
book.book Page 449 Wednesday, March 6, 2013 12:37 AM
COO Depreciation Duration Type
Name
cooDepreciationDurationType
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.36
Description
Defines the unit of time for the depreciation of this system.
Syntax
DellCooMonthYearDurationType
Access
Read-write
COO Depreciation Percentage
Name
cooDepreciationPercentage
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.37
Description
Defines the percentage of depreciation for this system.
Syntax
DellUnsigned32BitRange
Access
Read-write
COO Depreciation Method Name
Name
cooDepreciationMethodName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.38
Description
Defines the name of the depreciation method for this system.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Registration Is Registered
Name
cooRegistrationIsRegistered
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.39
Description
Specifies whether this system is registered or not.
Syntax
DellBoolean
Access
Read-write
Cost of Ownership Group
449
book.book Page 450 Wednesday, March 6, 2013 12:37 AM
COO Service Contract Table
The service contract table provides MIB objects that help you track the name,
vendor, and type of service contract you have for your system.
Name
cooServiceContractTable
Object ID
1.3.6.1.4.1.674.10892.1.1600.20
Description
Defines the COO Service Contract Table.
Syntax
SEQUENCE OF CooServiceContractTableEntry
Access
Not accessible
COO Service Contract Table Entry
Name
cooServiceContractTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1600.20.1
Description
Defines the COO Service Contract Table entry.
Syntax
CooServiceContractTableEntry
Access
Not accessible
Index
cooServiceContractchassisIndex, cooServiceContractIndex
COO Service Contract Chassis Index
Name
cooServiceContractchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.20.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
COO Service Contract Index
Name
cooServiceContractIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.20.1.2
Description
Defines the index (one-based) of this service contract.
Syntax
DellObjectRange
Access
Read-only
450
Cost of Ownership Group
book.book Page 451 Wednesday, March 6, 2013 12:37 AM
COO Service Contract State
Name
cooServiceContractState
Object ID
1.3.6.1.4.1.674.10892.1.1600.20.1.3
Description
Defines the status of the service contract for this system.
Syntax
DellStateSettings
Access
Read-only
COO Service Contract Was Renewed
Name
cooServiceContractWasRenewed
Object ID
1.3.6.1.4.1.674.10892.1.1600.20.1.4
Description
Specifies whether the service contract for this system was
renewed.
Syntax
DellBoolean
Access
Read-write
COO Service Contract Type Name
Name
cooServiceContractTypeName
Object ID
1.3.6.1.4.1.674.10892.1.1600.20.1.5
Description
Defines the name of the service contract type for this system.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Service Contract Vendor Name
Name
cooServiceContractVendorName
Object ID
1.3.6.1.4.1.674.10892.1.1600.20.1.6
Description
Defines the name of the service contract provider for this
system.
Syntax
DellCostofOwnershipString
Access
Read-write
Cost of Ownership Group
451
book.book Page 452 Wednesday, March 6, 2013 12:37 AM
COO Cost Event Log Table
The COO Cost Event Log Table provides MIB objects that allow you to track
the duration and type of events that are logged for a particular system.
Name
cooCostEventLogTable
Object ID
1.3.6.1.4.1.674.10892.1.1600.30
Description
Defines the COO Cost Event Log Table.
Syntax
SEQUENCE OF COO CostEventLogTableEntry
Access
Not accessible
COO Cost Event Log Table Entry
Name
cooCostEventLogTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1600.30.1
Description
Defines the COO Cost Event Log Table entry.
Syntax
cooCostEventLogTableEntry
Access
Not accessible
Index
cooCostEventLogchassisIndex, cooCostEventLogIndex
COO Cost Event Log Chassis Index
Name
cooCostEventLogchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.30.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
COO Cost Event Log Index
Name
cooCostEventLogIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.30.1.2
Description
Defines the index (one-based) of the cost event log.
Syntax
DellObjectRange
Access
Read-only
452
Cost of Ownership Group
book.book Page 453 Wednesday, March 6, 2013 12:37 AM
COO Cost Event Log State
Name
cooCostEventLogState
Object ID
1.3.6.1.4.1.674.10892.1.1600.30.1.3
Description
Defines the cost event log state of this system.
Syntax
DellStateSettings
Access
Read-only
COO Cost Event Log Duration
Name
cooCostEventLogDuration
Object ID
1.3.6.1.4.1.674.10892.1.1600.30.1.4
Description
Defines the duration of the event for this system.
Syntax
DellUnsigned32BitRange
Access
Read-write
COO Cost Event Log Duration Type
Name
cooCostEventLogDurationType
Object ID
1.3.6.1.4.1.674.10892.1.1600.30.1.5
Description
Defines the duration type of the event for this system.
Syntax
DellCOOHourDayDurationType (See Table 18-2)
Access
Read-write
COO Cost Event Log Description Name
Name
cooCostEventLogDescriptionName
Object ID
1.3.6.1.4.1.674.10892.1.1600.30.1.6
Description
Defines the name of the event description.
Syntax
DellCostofOwnershipString
Access
Read-write
Cost of Ownership Group
453
book.book Page 454 Wednesday, March 6, 2013 12:37 AM
COO Warranty Table
The COO Warranty Table objects enable you to track facts about the type
and duration of the warranty for a particular system.
Name
cooWarrantyTable
Object ID
1.3.6.1.4.1.674.10892.1.1600.40
Description
Defines the COO Warranty Table.
Syntax
SEQUENCE OF CooWarrantyTableEntry
Access
Not accessible
COO Warranty Table Entry
Name
cooWarrantyTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1600.40.1
Description
Defines the COO Warranty Table entry.
Syntax
CooWarrantyTableEntry
Access
Not accessible
Index
cooWarrantychassisIndex, cooWarrantyIndex
COO Warranty Chassis Index
Name
cooWarrantychassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.40.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-write
COO Warranty Index
Name
cooWarrantyIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.40.1.2
Description
Defines the index of the warranty for this system.
Syntax
DellObjectRange
Access
Read-only
454
Cost of Ownership Group
book.book Page 455 Wednesday, March 6, 2013 12:37 AM
COO Warranty State
Name
cooWarrantyState
Object ID
1.3.6.1.4.1.674.10892.1.1600.40.1.3
Description
Defines the state of the warranty for this system.
Syntax
DellStateSettings
Access
Read-only
COO Warranty Duration
Name
cooWarrantyDuration
Object ID
1.3.6.1.4.1.674.10892.1.1600.40.1.4
Description
Defines the duration of the warranty.
Syntax
DellUnsigned32BitRange
Access
Read-write
COO Warranty Duration Type
Name
cooWarrantyDurationType
Object ID
1.3.6.1.4.1.674.10892.1.1600.40.1.5
Description
Defines the warranty duration type for the system.
Syntax
DellCOODayMonthDurationType
Access
Read-write
COO Warranty End Date Name
Name
cooWarrantyEndDateName
Object ID
1.3.6.1.4.1.674.10892.1.1600.40.1.6
Description
Defines the warranty end date for this system.
Syntax
DellDateName
Access
Read-write
Cost of Ownership Group
455
book.book Page 456 Wednesday, March 6, 2013 12:37 AM
COO Warranty Cost
Name
cooWarrantyCost
Object ID
1.3.6.1.4.1.674.10892.1.1600.40.1.7
Description
Defines the cost of the warranty for this system.
Syntax
DellUnsigned32BitRange
Access
Read-write
COO Lease Information Table
The COO lease information MIB objects enable you to track information
about your lessor, lease duration, and lease type for each system.
Name
cooLeaseInformationTable
Object ID
1.3.6.1.4.1.674.10892.1.1600.50
Description
Defines the COO Lease Information Table.
Syntax
SEQUENCE OF CooLeaseInformationTableEntry
Access
Not accessible
COO Lease Information Table Entry
Name
cooLeaseInformationTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1600.50.1
Description
Defines the COO Lease Information Table entry.
Syntax
CooLeaseInformationTableEntry
Access
Not accessible
Index
cooLeaseInformationchassisIndex, cooLeaseInformationIndex
COO Lease Information Chassis Index
Name
cooLeaseInformationchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.50.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
456
Cost of Ownership Group
book.book Page 457 Wednesday, March 6, 2013 12:37 AM
COO Lease Information Index
Name
cooLeaseInformationIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.50.1.2
Description
Defines the index of the lease information for this system.
Syntax
DellObjectRange
Access
Read-only
COO Lease Information State
Name
cooLeaseInformationState
Object ID
1.3.6.1.4.1.674.10892.1.1600.50.1.3
Description
Defines the lease information state for this system.
Syntax
DellStateSettings
Access
Read-write
COO Lease Information Multiple Schedules
Name
cooLeaseInformationMultipleSchedules
Object ID
1.3.6.1.4.1.674.10892.1.1600.50.1.4
Description
Defines whether there are multiple schedules for this lease.
Syntax
DellBoolean
Access
Read-only
COO Lease Information Buyout Amount
Name
cooLeaseInformationBuyOutAmount
Object ID
1.3.6.1.4.1.674.10892.1.1600.50.1.5
Description
Defines the balance purchase price for this system.
Syntax
DellUnsigned32BitRange
Access
Read-write
Cost of Ownership Group
457
book.book Page 458 Wednesday, March 6, 2013 12:37 AM
COO Lease Information Lease Rate Factor
Name
cooLeaseInformationLeaseRateFactor
Object ID
1.3.6.1.4.1.674.10892.1.1600.50.1.6
Description
Defines the rate factor for the lease on this system.
Syntax
DellUnsigned32BitRange
Access
Read-write
COO Lease Information End Date Name
Name
cooLeaseInformationEndDateName
Object ID
1.3.6.1.4.1.674.10892.1.1600.50.1.7
Description
Defines the end date for the lease on this system.
Syntax
DellDateName
Access
Read-write
COO Lease Information Fair Market Value
Name
cooLeaseInformationFairMarketValue
Object ID
1.3.6.1.4.1.674.10892.1.1600.50.1.8
Description
Defines the fair market value of this system.
Syntax
DellUnsigned32BitRange
Access
Read-write
COO Lease Information Lessor Name
Name
cooLeaseInformationLessorName
Object ID
1.3.6.1.4.1.674.10892.1.1600.50.1.9
Description
Defines the name of the lessor of this system.
Syntax
DellCostofOwnershipString
Access
Read-write
458
Cost of Ownership Group
book.book Page 459 Wednesday, March 6, 2013 12:37 AM
COO Schedule Number Table
Name
cooScheduleNumberTable
Object ID
1.3.6.1.4.1.674.10892.1.1600.60
Description
Defines the COO Schedule Number Information Table.
Syntax
SEQUENCE OF CooScheduleNumberTableEntry
Access
Not accessible
COO Schedule Number Table Entry
Name
cooScheduleNumberTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1600.60.1
Description
Defines the COO Schedule Number Information Table entry.
Syntax
CooScheduleNumberTableEntry
Access
Not accessible
Index
cooScheduleNumberchassisIndex, cooScheduleNumberIndex
COO Schedule Number Chassis Index
Name
cooScheduleNumberchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.60.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
COO Schedule Number Index
Name
cooScheduleNumberIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.60.1.2
Description
Defines the index of the schedule number information.
Syntax
DellObjectRange
Access
Read-only
Cost of Ownership Group
459
book.book Page 460 Wednesday, March 6, 2013 12:37 AM
COO Schedule Number State
Name
cooScheduleNumberState
Object ID
1.3.6.1.4.1.674.10892.1.1600.60.1.3
Description
Defines the schedule number information state of this system.
Syntax
DellStateSettings
Access
Read-only
COO Schedule Number Lease Information Index Reference
Name
cooScheduleNumberLeaseInformationIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1600.60.1.4
Description
Defines the lease information index number to reference the
schedule number.
Syntax
DellUnsigned32BitRange
Access
Read-write
COO Schedule Number Description Name
Name
cooScheduleNumberDescriptionName
Object ID
1.3.6.1.4.1.674.10892.1.1600.60.1.5
Description
Describes the schedule number information.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Options Table
Name
cooOptionsTable
Object ID
1.3.6.1.4.1.674.10892.1.1600.70
Description
Defines the COO Options Table.
Syntax
SEQUENCE OF CooOptionsTableEntry
Access
Not accessible
460
Cost of Ownership Group
book.book Page 461 Wednesday, March 6, 2013 12:37 AM
COO Options Table Entry
Name
cooOptionsTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1600.70.1
Description
Defines the COO Options Table entry.
Syntax
CooOptionsTableEntry
Access
Not accessible
Index
cooOptionschassisIndex, cooOptionsIndex
COO Options Chassis Index
Name
cooOptionschassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.70.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
COO Options Index
Name
cooOptionsIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.70.1.2
Description
Defines the index (one-based) of the option information for this
system.
Syntax
DellObjectRange
Access
Read-only
COO Options State
Name
cooOptionsState
Object ID
1.3.6.1.4.1.674.10892.1.1600.70.1.3
Description
Defines the option information state for this system.
Syntax
DellStateSettings
Access
Read-only
Cost of Ownership Group
461
book.book Page 462 Wednesday, March 6, 2013 12:37 AM
COO Options Lease Information Index Reference
Name
cooOptionsLeaseInformationIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1600.70.1.4
Description
Defines the lease information index of the option information for
this system.
Syntax
DellUnsigned32BitRange
Access
Read-write
COO Options Description Name
Name
cooOptionsDescriptionName
Object ID
1.3.6.1.4.1.674.10892.1.1600.70.1.5
Description
Defines the option information description name.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Maintenance Table
Name
cooMaintenanceTable
Object ID
1.3.6.1.4.1.674.10892.1.1600.80
Description
Defines the COO Maintenance Table.
Syntax
SEQUENCE OF CooMaintenanceTableEntry
Access
Not accessible
COO Maintenance Table Entry
Name
cooMaintenanceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1600.80.1
Description
Defines the COO Maintenance Table entry.
Syntax
CooMaintenanceTableEntry
Access
Not accessible
Index
cooMaintenancechassisIndex, cooMaintenanceIndex
462
Cost of Ownership Group
book.book Page 463 Wednesday, March 6, 2013 12:37 AM
COO Maintenance Chassis Index
Name
cooMaintenancechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.80.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
COO Maintenance Index
Name
cooMaintenanceIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.80.1.2
Description
Defines the index of this system’s maintenance information.
Syntax
DellObjectRange
Access
Read-only
COO Maintenance State
Name
cooMaintenanceState
Object ID
1.3.6.1.4.1.674.10892.1.1600.80.1.3
Description
Defines the state of this system’s maintenance information.
Syntax
DellStateSettings
Access
Read-only
COO Maintenance Start Date Name
Name
cooMaintenanceStartDateName
Object ID
1.3.6.1.4.1.674.10892.1.1600.80.1.4
Description
Defines the start date for maintenance on this system.
Syntax
DellDateName
Access
Read-write
Cost of Ownership Group
463
book.book Page 464 Wednesday, March 6, 2013 12:37 AM
COO Maintenance End Date Name
Name
cooMaintenanceEndDateName
Object ID
1.3.6.1.4.1.674.10892.1.1600.80.1.5
Description
Defines the end date for maintenance on this system.
Syntax
DellDateName
Access
Read-write
COO Maintenance Provider Name
Name
cooMaintenanceProviderName
Object ID
1.3.6.1.4.1.674.10892.1.1600.80.1.6
Description
Defines the maintenance provider’s name.
Syntax
DellStateSettings
Access
Read-write
COO Maintenance Restrictions Name
Name
cooMaintenanceRestrictionsName
Object ID
1.3.6.1.4.1.674.10892.1.1600.80.1.7
Description
Defines the maintenance agreement restrictions.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Repair Table
Name
cooRepairTable
Object ID
1.3.6.1.4.1.674.10892.1.1600.90
Description
Defines the COO Repair Table.
Syntax
SEQUENCE OF CooRepairTableEntry
Access
Not accessible
464
Cost of Ownership Group
book.book Page 465 Wednesday, March 6, 2013 12:37 AM
COO Repair Table Entry
Name
cooRepairTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1600.90.1
Description
Defines the COO Repair Table entry.
Syntax
CooRepairTableEntry
Access
Not accessible
Index
cooRepairchassisIndex, cooRepairIndex
COO Repair Chassis Index
Name
cooRepairchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.90.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
COO Repair Index
Name
cooRepairIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.90.1.2
Description
Defines the index (one-based) of the repair information for this
system.
Syntax
DellObjectRange
Access
Read-only
COO Repair State
Name
cooRepairState
Object ID
1.3.6.1.4.1.674.10892.1.1600.90.1.3
Description
Defines the state of the repair information for this system.
Syntax
DellStateSettings
Access
Read-only
Cost of Ownership Group
465
book.book Page 466 Wednesday, March 6, 2013 12:37 AM
COO Repair Counter
Name
cooRepairCounter
Object ID
1.3.6.1.4.1.674.10892.1.1600.90.1.4
Description
Defines the number of repairs that this system has undergone.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Repair Vendor Name
Name
cooRepairVendorName
Object ID
1.3.6.1.4.1.674.10892.1.1600.90.1.5
Description
Defines the name of the vendor that repairs this system.
Syntax
DellStateSettings
Access
Read-only
COO Support Information Table
Name
cooSupportInformationTable
Object ID
1.3.6.1.4.1.674.10892.1.1600.100
Description
Defines the COO Support Information Table.
Syntax
SEQUENCE OF cooSupportInformationTableEntry
Access
Not accessible
COO Support Information Table Entry
Name
cooSupportInformationTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1600.100.1
Description
Defines the COO Support Information Table entry.
Syntax
cooSupportInformationTableEntry
Access
Not accessible
Index
cooSupportInformationchassisIndex
cooSupportInformationIndex
466
Cost of Ownership Group
book.book Page 467 Wednesday, March 6, 2013 12:37 AM
COO Support Information Chassis Index
Name
cooSupportInformationchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.100.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
COO Support Information Index
Name
cooSupportInformationIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.100.1.2
Description
Defines the index (one-based) for this system’s support
information.
Syntax
DellObjectRange
Access
Read-only
COO Support Information State
Name
cooSupportInformationState
Object ID
1.3.6.1.4.1.674.10892.1.1600.100.1.3
Description
Defines the support information state for this system.
Syntax
DellStateSettings
Access
Read-only
COO Support Information Is Outsourced
Name
cooSupportInformationIsOutsourced
Object ID
1.3.6.1.4.1.674.10892.1.1600.100.1.4
Description
Specifies whether the support for this system is outsourced or not.
Syntax
DellBoolean
Access
Read-write
Cost of Ownership Group
467
book.book Page 468 Wednesday, March 6, 2013 12:37 AM
COO Support Information Type
Name
cooSupportInformationType
Object ID
1.3.6.1.4.1.674.10892.1.1600.100.1.5
Description
Defines the type of component, system, or network problem that
occurred.
Syntax
DellUnsigned32BitRange
Access
Read-write
COO Support Information Help Desk Name
Name
cooSupportInformationHelpDeskName
Object ID
1.3.6.1.4.1.674.10892.1.1600.100.1.6
Description
Defines the help desk information provided.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Support Information Fix Type Name
Name
cooSupportInformationFixTypeName
Object ID
1.3.6.1.4.1.674.10892.1.1600.100.1.7
Description
Defines the method used to fix the problem.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Trouble Ticket Table
The MIB objects in the Trouble Ticket Table enable you to track details of
any trouble tickets that you open for your system.
Name
cooTroubleTicketTable
Object ID
1.3.6.1.4.1.674.10892.1.1600.110
Description
Defines the COO Trouble Ticket Table.
Syntax
SEQUENCE OF cooTroubleTicketTableEntry
Access
Not accessible
468
Cost of Ownership Group
book.book Page 469 Wednesday, March 6, 2013 12:37 AM
COO Trouble Ticket Table Entry
Name
cooTroubleTicketTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1600.110.1
Description
Defines the COO Trouble Ticket Table entry.
Syntax
cooTroubleTicketTableEntry
Access
Not accessible
Index
cooTroubleTicketchassisIndex, cooTroubleTicketIndex
COO Trouble Ticket Chassis Index
Name
cooTroubleTicketchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.110.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
COO Trouble Ticket Index
Name
cooTroubleTicketIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.110.1.2
Description
Defines the index (one-based) of the system’s trouble ticket
information.
Syntax
DellObjectRange
Access
Read-only
COO Trouble Ticket State
Name
cooTroubleTicketState
Object ID
1.3.6.1.4.1.674.10892.1.1600.110.1.3
Description
Defines the trouble ticket information state for this system.
Syntax
DellStateSettings
Access
Read-only
Cost of Ownership Group
469
book.book Page 470 Wednesday, March 6, 2013 12:37 AM
COO Trouble Ticket Support Information Index Reference
Name
cooTroubleTicketSupportInformationIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1600.110.1.4
Description
Defines the support information index that references the trouble ticket.
Syntax
DellUnsigned32BitRange
Access
Read-write
COO Trouble Ticket Number Name
Name
cooTroubleTicketNumberName
Object ID
1.3.6.1.4.1.674.10892.1.1600.110.1.5
Description
Defines the trouble ticket number for this system.
Syntax
DellCostofOwnershipString
Access
Read-write
Cost of Ownership Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 18-1. COO Ownership Codes
Variable Name: DellCooOwnershipCodes
Data Type: Integer
Possible Data Values
Meaning of Data Value
other(1)
The ownership code is not one of following:
unknown(2)
The ownership code is unknown.
owned(3)
The ownership code is owned.
leased(4)
The ownership code is leased.
rented(5)
The ownership code is rented.
offOfLease(6)
The ownership code is off of lease.
transfer(7)
The ownership code is transfer.
470
Cost of Ownership Group
book.book Page 471 Wednesday, March 6, 2013 12:37 AM
Table 18-2.
COO Hour Day Duration Type
Variable Name: DellCooHourDayDurationType
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
Duration time type is unknown.
hours(2)
Duration time type is in hours.
days(3)
Duration time type is in days.
Table 18-3.
COO Day Month Duration Type
Variable Name: DellCooDayMonthDurationType
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
Duration time type is unknown.
days(3)
Duration time type is in days.
months(4)
Duration time type is in months.
Table 18-4.
COO Month Year Duration Type
Variable Name: DellCooMonthYearDurationType
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
Duration time type is unknown.
months(4)
Duration time type is in months.
years(5)
Duration time type is in years.
Cost of Ownership Group
471
book.book Page 472 Wednesday, March 6, 2013 12:37 AM
472
Cost of Ownership Group
book.book Page 473 Wednesday, March 6, 2013 12:37 AM
Remote Access Group
19
The Remote Access Group provides information about the remote access
hardware that may be present in your system. In addition to providing general
information about the capabilities and settings of the remote access
hardware, this group provides information about administrative users,
SNMP trap destinations, modem configuration for dial-up networking,
dial-in configuration, and dial-out destinations.
DRAC 4 and DRAC 5
On systems with Dell Remote Access Controller (DRAC) 4 or DRAC 5,
the Remote Access Group includes only the Remote Access Table.
Remote Access Table
The following MIB object sets up the Remote Access Table.
Name
remoteAccessTable
Object ID
1.3.6.1.4.1.674.10892.1.1700.10
Description
Defines the Remote Access Table.
Syntax
SEQUENCE OF RemoteAccessTableEntry
Access
Not accessible
Remote Access Table Entry
Name
remoteAccessTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1
Description
Defines the Remote Access Table entry.
Syntax
RemoteAccessTableEntry
Access
Not accessible
Index
remoteAccessChassisIndex, remoteAccessAdapterIndex
Remote Access Group
473
book.book Page 474 Wednesday, March 6, 2013 12:37 AM
Remote Access Chassis Index
Name
remoteAccessChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.1
Description
Defines the index (one-based) of the chassis containing the
remote access hardware.
Syntax
DellObjectRange
Access
Read-only
Remote Access Adapter Index
Name
remoteAccessAdapterIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.2
Description
Defines the index (one-based) of the remote access hardware.
Syntax
DellObjectRange
Access
Read-only
Remote Access Type
Name
remoteAccessType
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.3
Description
Defines the type of remote access hardware.
Syntax
DellRemoteAccessType (See Table 19-1)
Access
Read-only
Remote Access State Capabilities
Name
remoteAccessStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.4
Description
Defines the state capabilities of the remote access hardware.
Syntax
DellStateCapabilities
Access
Read-only
474
Remote Access Group
book.book Page 475 Wednesday, March 6, 2013 12:37 AM
Remote Access State Settings
Name
remoteAccessStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.5
Description
Defines the state setting of the remote access hardware.
Syntax
DellStateSettings
Access
Read-write
Remote Access Status
Name
remoteAccessStatus
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.6
Description
Defines the status of the remote access hardware.
Syntax
DellStatus
Access
Read-only
Remote Access Product Info Name
Name
remoteAccessProductInfoName
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.7
Description
Defines the name of the product providing the remote access
functionality.
Syntax
DellDisplayString (SIZE (0..63))
Access
Read-only
Remote Access Description Info Name
Name
remoteAccessDescriptionInfoName
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.8
Description
Defines the description of the product providing the remote
access functionality.
Syntax
DellDisplayString (SIZE (0..255))
Access
Read-only
Remote Access Group
475
book.book Page 476 Wednesday, March 6, 2013 12:37 AM
Remote Access Version Info Name
Name
remoteAccessVersionInfoName
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.9
Description
Defines the version of the product providing the remote access
functionality.
Syntax
DellDisplayString (SIZE (0..63))
Access
Read-only
Remote Access Local Area Network (LAN) Capabilities
Name
remoteAccessLANCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.14
Description
Defines the LAN capabilities of the remote access hardware.
Syntax
DellRemoteAccessLANCapabilities (See Table 19-6)
Access
Read-only
Remote Access LAN Settings
Name
remoteAccessLANSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.15
Description
Defines the LAN settings of the remote access hardware.
Syntax
DellRemoteAccessLANSettings (See Table 19-7)
Access
Read-write
Remote Access Network Interface Controller (NIC) Static IP Address
Name
remoteAccessNICStaticIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.25
Description
Defines the static IP address to be used by the integrated NIC
provided by the remote access hardware.
Syntax
IpAddress
Access
Read-write
476
Remote Access Group
book.book Page 477 Wednesday, March 6, 2013 12:37 AM
Remote Access NIC Static Netmask Address
Name
remoteAccessNICStaticNetmaskAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.26
Description
Defines the netmask for the static IP address to be used by the
integrated NIC provided by the remote access hardware.
Syntax
IpAddress
Access
Read-write
Remote Access NIC Static Gateway Address
Name
remoteAccessNICStaticGatewayAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.27
Description
Defines the IP address for the gateway associated with the static
IP address to be used by the integrated NIC provided by the
remote access hardware.
Syntax
IpAddress
Access
Read-write
Remote Access Personal Computer Memory Card International Association
(PCMCIA) Info Name
Name
remoteAccessPCMCIAInfoName
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.28
Description
Defines the information for the PCMCIA device used by the
remote access hardware.
Syntax
DisplayString (SIZE (0..63))
Access
Read-only
Remote Access Group
477
book.book Page 478 Wednesday, March 6, 2013 12:37 AM
Remote Access Miscellaneous Information Name
Name
remoteAccessMiscInfoName
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.29
Description
Defines the miscellaneous information for the remote access hardware.
Syntax
DisplayString (SIZE (0..63))
Access
Read-write
Remote Access NIC Current IP Address
Name
remoteAccessNICCurrentIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.30
Description
Defines the IP address currently being used by the integrated
NIC provided by the remote access hardware.
Syntax
IpAddress
Access
Read-only
Remote Access NIC Current Netmask Address
Name
remoteAccessNICCurrentNetmaskAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.31
Description
Defines the netmask currently being used by the integrated NIC
provided by the remote access hardware.
Syntax
IpAddress
Access
Read-only
Remote Access NIC Current Gateway Address
Name
remoteAccessNICCurrentGatewayAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.32
Description
Defines the IP address for the gateway currently being used by
the integrated NIC provided by the remote access hardware.
Syntax
IpAddress
Access
Read-only
478
Remote Access Group
book.book Page 479 Wednesday, March 6, 2013 12:37 AM
Remote Access NIC Current Information From Dynamic Host Configuration Protocol
(DHCP)
Name
remoteAccessNICCurrentInfoFromDHCP
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.33
Description
Defines whether DHCP was used to obtain the NIC
information currently being used by the integrated NIC
provided by the remote access hardware.
Syntax
DellBoolean
Access
Read-only
Remote Access Remote Connect URL
Name
remoteAccessRemoteConnectURL
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.34
Description
Defines the URL for launching the Remote Access Remote
Connect Interface.
Syntax
DisplayString (SIZE (0..63))
Access
Mandatory
DRAC III
On systems with DRAC III, the Remote Access Group includes the following
MIB tables:
•
"Remote Access Table" on page 480
•
"Remote User Administration Table" on page 489
•
"Remote SNMP Trap Table" on page 497
•
"Remote Dial-Up Table" on page 502
•
"Remote User Dial-In Configuration Table" on page 506
•
"Remote Dial-Out Table" on page 509
Remote Access Group
479
book.book Page 480 Wednesday, March 6, 2013 12:37 AM
Remote Access Table
The following MIB object sets up the Remote Access Table.
Name
remoteAccessTable
Object ID
1.3.6.1.4.1.674.10892.1.1700.10
Description
Defines the Remote Access Table.
Syntax
SEQUENCE OF RemoteAccessTableEntry
Access
Not accessible
Remote Access Table Entry
Name
remoteAccessTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1
Description
Defines the Remote Access Table entry.
Syntax
RemoteAccessTableEntry
Access
Not accessible
Index
remoteAccessChassisIndex, remoteAccessAdapterIndex
Remote Access Chassis Index
Name
remoteAccessChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.1
Description
Defines the index (one-based) of the chassis containing the
remote access hardware.
Syntax
DellObjectRange
Access
Read-only
Remote Access Adapter Index
Name
remoteAccessAdapterIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.2
Description
Defines the index (one-based) of the remote access hardware.
Syntax
DellObjectRange
Access
Read-only
480
Remote Access Group
book.book Page 481 Wednesday, March 6, 2013 12:37 AM
Remote Access Type
Name
remoteAccessType
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.3
Description
Defines the type of remote access hardware.
Syntax
DellRemoteAccessType (See Table 19-1)
Access
Read-only
Remote Access State Capabilities
Name
remoteAccessStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.4
Description
Defines the state capabilities of the remote access hardware.
Syntax
DellStateCapabilities
Access
Read-only
Remote Access State Settings
Name
remoteAccessStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.5
Description
Defines the state setting of the remote access hardware.
Syntax
DellStateSettings
Access
Read-write
Remote Access Status
Name
remoteAccessStatus
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.6
Description
Defines the status of the remote access hardware.
Syntax
DellStatus
Access
Read-only
Remote Access Group
481
book.book Page 482 Wednesday, March 6, 2013 12:37 AM
Remote Access Product Info Name
Name
remoteAccessProductInfoName
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.7
Description
Defines the name of the product providing the remote access
functionality.
Syntax
DellDisplayString (SIZE (0..63))
Access
Read-only
Remote Access Description Info Name
Name
remoteAccessDescriptionInfoName
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.8
Description
Defines the description of the product providing the remote access
functionality.
Syntax
DellDisplayString (SIZE (0..255))
Access
Read-only
Remote Access Version Info Name
Name
remoteAccessVersionInfoName
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.9
Description
Defines the version of the product providing the remote access
functionality.
Syntax
DellDisplayString (SIZE (0..63))
Access
Read-only
Remote Access Control Capabilities
Name
remoteAccessControlCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.10
Description
Defines the control capabilities of the remote access hardware.
Syntax
DellRemoteAccessControlCapabilities (See Table 19-2)
Access
Read-only
482
Remote Access Group
book.book Page 483 Wednesday, March 6, 2013 12:37 AM
Remote Access Control Settings
Name
remoteAccessControlSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.11
Description
Defines the control settings of the remote access hardware.
Syntax
DellRemoteAccessControlSettings (See Table 19-3)
Access
Read-write
Remote Access Monitor Capabilities
Name
remoteAccessMonitorCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.12
Description
Defines the monitor capabilities of the remote access hardware.
Syntax
DellRemoteAccessMonitorCapabilities (See Table 19-4)
Access
Read-only
Remote Access Monitor Settings
Name
remoteAccessMonitorSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.13
Description
Defines the monitor settings of the remote access hardware.
Syntax
DellRemoteAccessMonitorSettings (See Table 19-5)
Access
Read-write
Remote Access Local Area Network (LAN) Capabilities
Name
remoteAccessLANCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.14
Description
Defines the LAN capabilities of the remote access hardware.
Syntax
DellRemoteAccessLANCapabilities (See Table 19-6)
Access
Read-only
Remote Access Group
483
book.book Page 484 Wednesday, March 6, 2013 12:37 AM
Remote Access LAN Settings
Name
remoteAccessLANSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.15
Description
Defines the LAN settings of the remote access hardware.
Syntax
DellRemoteAccessLANSettings (See Table 19-7)
Access
Read-write
Remote Access Host Capabilities
Name
remoteAccessHostCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.16
Description
Defines the host capabilities of the remote access hardware.
Syntax
DellRemoteAccessHostCapabilities (See Table 19-8)
Access
Read-only
Remote Access Host Settings
Name
remoteAccessHostSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.17
Description
Defines the host settings of the remote access hardware.
Syntax
DellRemoteAccessHostSettings (See Table 19-9)
Access
Read-write
Remote Access Out-of-Band Simple Network Management Protocol (SNMP)
Capabilities
Name
remoteAccessOutOfBandSNMPCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.18
Description
Defines the out-of-band SNMP capabilities of the remote access
hardware.
Syntax
DellRemoteAccessOutOfBandSNMPCapabilities (See
Table 19-10)
Access
Read-only
484
Remote Access Group
book.book Page 485 Wednesday, March 6, 2013 12:37 AM
Remote Access Out-of-Band SNMP Settings
Name
remoteAccessOutOfBandSNMPSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.19
Description
Defines the out-of-band SNMP settings of the remote access hardware.
Syntax
DellRemoteAccessOutOfBandSNMPSettings (See Table 19-11)
Access
Read-write
Remote Access Simple Mail Transfer Protocol (SMTP) Server Internet Protocol (IP)
Address
Name
remoteAccessSMTPServerIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.20
Description
Defines the IP address for the SMTP server used by the remote
access hardware.
Syntax
IpAddress
Access
Read-write
Remote Access Floppy Trivial File Transfer Protocol (TFTP) IP Address
Name
remoteAccessFloppyTFTPIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.21
Description
Defines the IP address of the TFTP server providing the
operating system image used by the remote access hardware.
Syntax
IpAddress
Access
Read-write
Remote Access Floppy TFTP Path Name
Name
remoteAccessFloppyTFTPPathName
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.22
Description
Defines the file name of the operating system image obtained
from the TFTP server used by the remote access hardware.
Syntax
DisplayString (SIZE (0..255))
Access
Read-write
Remote Access Group
485
book.book Page 486 Wednesday, March 6, 2013 12:37 AM
Remote Access Firmware Update IP Address
Name
remoteAccessFirmwareUpdateIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.23
Description
Defines the IP address of the update server providing the
firmware image used by the remote access hardware.
Syntax
IpAddress
Access
Read-write
Remote Access Firmware Update Path Name
Name
remoteAccessFirmwareUpdatePathName
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.24
Description
Defines the file name of the firmware image obtained from the
update server used by the remote access hardware.
Syntax
DisplayString (SIZE (0..255))
Access
Read-write
Remote Access Network Interface Controller (NIC) Static IP Address
Name
remoteAccessNICStaticIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.25
Description
Defines the static IP address to be used by the integrated NIC
provided by the remote access hardware.
Syntax
IpAddress
Access
Read-write
Remote Access NIC Static Netmask Address
Name
remoteAccessNICStaticNetmaskAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.26
Description
Defines the netmask for the static IP address to be used by the
integrated NIC provided by the remote access hardware.
Syntax
IpAddress
Access
Read-write
486
Remote Access Group
book.book Page 487 Wednesday, March 6, 2013 12:37 AM
Remote Access NIC Static Gateway Address
Name
remoteAccessNICStaticGatewayAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.27
Description
Defines the IP address for the gateway associated with the static
IP address to be used by the integrated NIC provided by the
remote access hardware.
Syntax
IpAddress
Access
Read-write
Remote Access Personal Computer Memory Card International Association (PCMCIA)
Info Name
Name
remoteAccessPCMCIAInfoName
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.28
Description
Defines the information for the PCMCIA device used by the
remote access hardware.
Syntax
DisplayString (SIZE (0..63))
Access
Read-only
Remote Access Miscellaneous Information Name
Name
remoteAccessMiscInfoName
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.29
Description
Defines the miscellaneous information for the remote
access hardware.
Syntax
DisplayString (SIZE (0..63))
Access
Read-write
Remote Access Group
487
book.book Page 488 Wednesday, March 6, 2013 12:37 AM
Remote Access NIC Current IP Address
Name
remoteAccessNICCurrentIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.30
Description
Defines the IP address currently being used by the integrated
NIC provided by the remote access hardware.
Syntax
IpAddress
Access
Read-only
Remote Access NIC Current Netmask Address
Name
remoteAccessNICCurrentNetmaskAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.31
Description
Defines the netmask currently being used by the integrated NIC
provided by the remote access hardware.
Syntax
IpAddress
Access
Read-only
Remote Access NIC Current Gateway Address
Name
remoteAccessNICCurrentGatewayAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.32
Description
Defines the IP address for the gateway currently being used by
the integrated NIC provided by the remote access hardware.
Syntax
IpAddress
Access
Read-only
488
Remote Access Group
book.book Page 489 Wednesday, March 6, 2013 12:37 AM
Remote Access NIC Current Information From Dynamic Host Configuration Protocol
(DHCP)
Name
remoteAccessNICCurrentInfoFromDHCP
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.33
Description
Defines whether DHCP was used to obtain the NIC
information currently being used by the integrated NIC
provided by the remote access hardware.
Syntax
DellBoolean
Access
Read-only
Remote User Administration Table
Name
remoteUserAdminTable
Object ID
1.3.6.1.4.1.674.10892.1.1700.20
Description
Defines the Remote Access User Administration Table.
Syntax
SEQUENCE OF RemoteUserAdminTableEntry
Access
Not accessible
Remote User Admin Table Entry
Name
remoteUserAdminTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1
Description
Defines the Remote Access User Administration Table entry.
Syntax
RemoteUserAdminTableEntry
Access
Not accessible
Index
remoteUserAdminChassisIndex,
remoteUserAdminAdapterIndex, remoteUserAdminUserIndex
Remote Access Group
489
book.book Page 490 Wednesday, March 6, 2013 12:37 AM
Remote User Admin Chassis Index
Name
remoteUserAdminChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.1
Description
Defines the index (one-based) of the chassis containing the
remote access hardware.
Syntax
DellObjectRange
Access
Read-only
Remote User Admin Adapter Index
Name
remoteUserAdminAdapterIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.2
Description
Defines the index (one-based) of the remote access hardware
used by this remote access user.
Syntax
DellObjectRange
Access
Read-only
Remote User Admin User Index
Name
remoteUserAdminUserIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.3
Description
Defines the index (one-based) of this remote access user.
Syntax
DellObjectRange
Access
Read-only
Remote User Admin State Capabilities
Name
remoteUserAdminStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.4
Description
Defines the state capabilities for this remote access user.
Syntax
DellRemoteUserAdminStateCapabilities (See Table 19-12)
Access
Read-only
490
Remote Access Group
book.book Page 491 Wednesday, March 6, 2013 12:37 AM
Remote User Admin State Settings
Name
remoteUserAdminStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.5
Description
Defines the state settings for this remote access user.
Syntax
DellRemoteUserAdminStateSettings (See Table 19-13)
Access
Read-write
Remote User Admin Status
Name
remoteUserAdminStatus
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.6
Description
Defines the status for this remote access user.
Syntax
DellStatus
Access
Read-only
Remote User Admin User Name
Name
remoteUserAdminUserName
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.7
Description
Defines the user name for this remote access user.
Syntax
DisplayString (SIZE (0..19))
Access
Read-write
Remote User Admin User Password Name
Name
remoteUserAdminUserPasswordName
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.8
Description
Defines the password for this remote access user.
Syntax
DisplayString (SIZE (0..255))
Access
Read-write
Remote Access Group
491
book.book Page 492 Wednesday, March 6, 2013 12:37 AM
Remote User Admin User Privilege
Name
remoteUserAdminUserPrivilege
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.9
Description
Defines the privileges for this remote access user.
Syntax
DisplayString (SIZE (0..31))
Access
Read-write
Remote User Admin User Privilege Capabilities
Name
remoteUserAdminUserPrivilegeCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.10
Description
Defines the privilege capabilities for this remote access user.
Syntax
DisplayString (SIZE (0..31))
Access
Read-only
Remote User Admin Alert Filter DRS Events Mask
Name
remoteUserAdminAlertFilterDrsEventsMask
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.11
Description
Defines the DRS events filter mask for this remote access user.
Syntax
DellUnsigned32BitRange
Access
Read-write
Remote User Admin Alert Filter System Events Mask
Name
remoteUserAdminAlertFilterSysEventsMask
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.12
Description
Defines the system events filter mask for this remote access user.
Syntax
DellUnsigned32BitRange
Access
Read-write
492
Remote Access Group
book.book Page 493 Wednesday, March 6, 2013 12:37 AM
Remote User Admin Alert Filter DRS Capabilities
Name
remoteUserAdminAlertFilterDrsCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.13
Description
Defines the DRS events filter capabilities for this remote access user.
Syntax
DellUnsigned32BitRange
Access
Read-only
Remote User Admin Alert Filter System Capabilities
Name
remoteUserAdminAlertFilterSysCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.14
Description
Defines the system events filter capabilities for this remote
access user.
Syntax
DellUnsigned32BitRange
Access
Read-only
Remote User Admin Pager Numeric Number Name
Name
remoteUserAdminPagerNumericNumberName
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.15
Description
Defines the numeric pager number for this remote access user.
Syntax
DisplayString (SIZE (0..95))
Access
Read-write
Remote User Admin Pager Numeric Message Name
Name
remoteUserAdminPagerNumericMessageName
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.16
Description
Defines the message to send to the numeric pager for this remote
access user.
Syntax
DisplayString (SIZE (0..31))
Access
Read-write
Remote Access Group
493
book.book Page 494 Wednesday, March 6, 2013 12:37 AM
Remote User Admin Pager Numeric Hang-up Delay
Name
remoteUserAdminPagerNumericHangupDelay
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.17
Description
Defines the numeric pager hang-up delay for this remote access user.
Syntax
DellUnsigned32BitRange
Access
Read-write
Remote User Admin Pager Alpha Phone Number Name
Name
remoteUserAdminPagerAlphaPhoneNumberName
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.18
Description
Defines the alphanumeric pager phone number for this remote
access user.
Syntax
DisplayString (SIZE (0..95))
Access
Read-write
Remote User Admin Pager Alpha Protocol
Name
remoteUserAdminPagerAlphaProtocol
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.19
Description
Defines the protocol used by the alphanumeric pager provider
for this remote access user.
Syntax
DellRemoteUserAdminAlphaProtocolType (See Table 19-16)
Access
Read-write
Remote User Admin Pager Alpha Baud Rate
Name
remoteUserAdminPagerAlphaBaudRate
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.20
Description
Defines the baud rate used by the alphanumeric pager provider
for this remote access user.
Syntax
DellRemoteUserAdminAlphaBaudType (See Table 19-17)
Access
Read-write
494
Remote Access Group
book.book Page 495 Wednesday, March 6, 2013 12:37 AM
Remote User Admin Pager Alpha Custom Message Name
Name
remoteUserAdminPagerAlphaCustomMessageName
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.21
Description
Defines the message to be sent to the alphanumeric pager to
inform the user of a call by this remote access user.
Syntax
DisplayString (SIZE (0..31))
Access
Read-write
Remote User Admin Pager Alpha Modem Connect Time-out
Name
remoteUserAdminPagerAlphaModemConnectTimeout
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.22
Description
Defines the modem connection time-out for the alphanumeric
pager for this remote access user.
Syntax
DellUnsigned32BitRange
Access
Read-write
Remote User Admin Pager Alpha Pager ID Name
Name
remoteUserAdminPagerAlphaPagerIdName
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.23
Description
Defines the ID to be sent to the alphanumeric pager to inform
the user of a call by this remote access user.
Syntax
DisplayString (SIZE (0..31))
Access
Read-write
Remote User Admin Pager Alpha Password Name
Name
remoteUserAdminPagerAlphaPasswordName
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.24
Description
Defines the password for the alphanumeric pager for this remote
access user.
Syntax
DisplayString (SIZE (0..31))
Access
Read-write
Remote Access Group
495
book.book Page 496 Wednesday, March 6, 2013 12:37 AM
Remote User Admin Pager Modem Init String Name
Name
remoteUserAdminPagerModemInitStringName
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.25
Description
Defines the initialization string to be sent to the pager modem
for this remote access user.
Syntax
DisplayString (SIZE (0..31))
Access
Read-write
Remote User Admin Pager Modem Port
Name
remoteUserAdminPagerModemPort
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.26
Description
Defines the port for the pager modem for this remote access
user.
Syntax
DellUnsigned32BitRange
Access
Read-write
Remote User Admin E-Mail Address Name
Name
remoteUserAdminEmailAddressName
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.27
Description
Defines the e-mail address for this remote access user.
Syntax
DisplayString (SIZE (0..63))
Access
Read-write
Remote User Admin E-Mail Custom Message Name
Name
remoteUserAdminEmailCustomMessageName
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.28
Description
Defines the e-mail message to send to this remote access user.
Syntax
DisplayString (SIZE (0..31))
Access
Read-write
496
Remote Access Group
book.book Page 497 Wednesday, March 6, 2013 12:37 AM
Remote User Admin Control Capabilities
Name
remoteUserAdminControlCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.29
Description
Defines the control capabilities for this remote access user.
Syntax
DellRemoteUserAdminControlCapabilities (See Table 19-14 on
page 519)
Access
Read-only
Remote User Admin Control Settings
Name
remoteUserAdminControlSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.30
Description
Defines the control settings for this remote access user.
Syntax
DellRemoteUserAdminControlSettings (See Table 19-15)
Access
Read-write
Remote User Admin User Type
Name
remoteUserAdminUserType
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.31
Description
Defines the type of user for this remote access user.
Syntax
DellUnsigned8BitRange
Access
Read-write
Remote SNMP Trap Table
Name
remoteSNMPTrapTable
Object ID
1.3.6.1.4.1.674.10892.1.1700.30
Description
Defines the Remote Access SNMP Trap Destination Table.
Syntax
SEQUENCE OF RemoteSNMPTrapTableEntry
Access
Not accessible
Remote Access Group
497
book.book Page 498 Wednesday, March 6, 2013 12:37 AM
Remote SNMP Trap Table Entry
Name
remoteSNMPTrapTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1
Description
Defines the Remote Access SNMP Trap Destination Table entry.
Syntax
RemoteSNMPTrapTableEntry
Access
Not accessible
Index
remoteSNMPTrapChassisIndex,
remoteSNMPTrapAdapterIndex, remoteSNMPTrapIndex
Remote SNMP Trap Chassis Index
Name
remoteSNMPTrapChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.1
Description
Defines the index (one-based) of the chassis containing the
remote access hardware.
Syntax
DellObjectRange
Access
Read-only
Remote SNMP Trap Adapter Index
Name
remoteSNMPTrapAdapterIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.2
Description
Defines the index (one-based) of the remote access hardware
that uses this SNMP trap destination.
Syntax
DellObjectRange
Access
Read-only
498
Remote Access Group
book.book Page 499 Wednesday, March 6, 2013 12:37 AM
Remote SNMP Trap Index
Name
remoteSNMPTrapIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.3
Description
Defines the index (one-based) of this remote access SNMP trap
destination.
Syntax
DellObjectRange
Access
Read-only
Remote SNMP Trap State Capabilities
Name
remoteSNMPTrapStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.4
Description
Defines the state capabilities of this remote access SNMP trap
destination.
Syntax
DellRemoteSNMPTrapStateCapabilities (See Table 19-18)
Access
Read-only
Remote SNMP Trap State Settings
Name
remoteSNMPTrapStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.5
Description
Defines the state settings of this remote access SNMP trap
destination.
Syntax
DellRemoteSNMPTrapStateSettings (See Table 19-19)
Access
Read-write
Remote SNMP Trap Status
Name
remoteSNMPTrapStatus
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.6
Description
Defines the status of this remote access SNMP trap destination.
Syntax
DellStatus
Access
Read-only
Remote Access Group
499
book.book Page 500 Wednesday, March 6, 2013 12:37 AM
Remote SNMP Trap Destination IP Address
Name
remoteSNMPTrapDestinationIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.7
Description
Defines the IP address of this remote access SNMP trap destination.
Syntax
IpAddress
Access
Read-write
Remote SNMP Trap SNMP Community Name
Name
remoteSNMPTrapSNMPCommunityName
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.8
Description
Defines the community for traps sent to this remote access
SNMP trap destination.
Syntax
DisplayString (SIZE (0..31))
Access
Read-write
Remote SNMP Trap Filter DRS Events Mask
Name
remoteSNMPTrapFilterDrsEventsMask
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.9
Description
Defines the DRS events filter mask for this remote access
SNMP trap destination.
Syntax
DellUnsigned32BitRange
Access
Read-write
Remote SNMP Trap Filter System Events Mask
Name
remoteSNMPTrapFilterSysEventsMask
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.10
Description
Defines the system events filter mask for this remote access
SNMP trap destination.
Syntax
DellUnsigned32BitRange
Access
Read-write
500
Remote Access Group
book.book Page 501 Wednesday, March 6, 2013 12:37 AM
Remote SNMP Trap Filter DRS Capabilities
Name
remoteSNMPTrapFilterDrsCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.11
Description
Defines the DRS events filter capabilities for this remote access
SNMP trap destination.
Syntax
DellUnsigned32BitRange
Access
Read-only
Remote SNMP Trap Filter System Capabilities
Name
remoteSNMPTrapFilterSysCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.12
Description
Defines the system events filter capabilities of this remote
access SNMP trap destination.
Syntax
DellUnsigned32BitRange
Access
Read-only
Remote SNMP Trap Control Capabilities
Name
remoteSNMPTrapControlCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.13
Description
Defines the control capabilities of this remote access
SNMP trap destination.
Syntax
DellRemoteSNMPTrapControlCapabilities (See Table 19-20)
Access
Read-only
Remote SNMP Trap Control Settings
Name
remoteSNMPTrapControlSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.14
Description
Defines the control settings of this remote access SNMP
trap destination.
Syntax
DellRemoteSNMPTrapControlSettings (See Table 19-21)
Access
Read-write
Remote Access Group
501
book.book Page 502 Wednesday, March 6, 2013 12:37 AM
Remote Dial-Up Table
Name
remoteDialUpTable
Object ID
1.3.6.1.4.1.674.10892.1.1700.40
Description
Defines the Remote Access Dial-Up Table.
Syntax
SEQUENCE OF RemoteDialUpTableEntry
Access
Not accessible
Remote Dial-Up Table Entry
Name
remoteDialUpTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1
Description
Defines the Remote Access Dial-Up Table entry.
Syntax
RemoteDialUpTableEntry
Access
Not accessible
Index
remoteDialUpChassisIndex, remoteDialUpAdapterIndex,
remoteDialUpIndex
Remote Dial-Up Chassis Index
Name
remoteDialUpChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.1
Description
Defines the index (one-based) of the chassis containing the
remote access hardware.
Syntax
DellObjectRange
Access
Read-only
502
Remote Access Group
book.book Page 503 Wednesday, March 6, 2013 12:37 AM
Remote Dial-Up Adapter Index
Name
remoteDialUpAdapterIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.2
Description
Defines the index (one-based) of the remote access hardware
that supports this remote access dial-up functionality.
Syntax
DellObjectRange
Access
Read-only
Remote Dial-Up Index
Name
remoteDialUpIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.3
Description
Defines the index (one-based) of this remote access dial-up
functionality.
Syntax
DellObjectRange
Access
Read-only
Remote Dial-Up State Capabilities
Name
remoteDialUpStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.4
Description
Defines the state capabilities of this remote access dial-up
functionality.
Syntax
DellRemoteDialUpStateCapabilities (See Table 19-22)
Access
Read-only
Remote Dial-Up State Settings
Name
remoteDialUpStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.5
Description
Defines the state settings of this remote access dial-up
functionality.
Syntax
DellRemoteDialUpStateSettings (See Table 19-23)
Access
Read-write
Remote Access Group
503
book.book Page 504 Wednesday, March 6, 2013 12:37 AM
Remote Dial-Up Status
Name
remoteDialUpStatus
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.6
Description
Defines the status of this remote access dial-up functionality.
Syntax
DellStatus
Access
Read-only
Remote Dial-Up PPP Dial-In Base IP Address
Name
remoteDialUpPPPDialInBaseIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.7
Description
Defines the base IP address of the PPP server for this remote
access dial-up functionality.
Syntax
IpAddress
Access
Read-write
Remote Dial-Up PPP Dial-In Idle Time-out
Name
remoteDialUpPPPDialInIdleTimeout
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.8
Description
Defines the PPP idle time-out value in seconds for this remote
access dial-up functionality.
Syntax
DellUnsigned32BitRange
Access
Read-write
Remote Dial-Up PPP Dial-In Maximum Connection Time-out
Name
remoteDialUpPPPDialInMaxConnectTimeout
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.9
Description
Defines the PPP connect time-out value in seconds for this
remote access dial-up functionality.
Syntax
DellUnsigned32BitRange
Access
Read-write
504
Remote Access Group
book.book Page 505 Wednesday, March 6, 2013 12:37 AM
Remote Dial-Up Dial-Out Modem Connect Time-out
Name
remoteDialUpDialOutModemConnectTimeout
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.10
Description
Defines the modem dial-out time-out value in seconds for this
remote access dial-up functionality.
Syntax
DellUnsigned32BitRange
Access
Read-write
Remote Dial-Up Modem Dial Type
Name
remoteDialUpModemDialType
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.11
Description
Defines the dial type for the modem used by this remote access
dial-up functionality.
Syntax
DellRemoteDialUpModemDialType (See Table 19-24)
Access
Read-write
Remote Dial-Up Modem Init String Name
Name
remoteDialUpModemInitStringName
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.12
Description
Defines the initialization string to be sent to the modem for this
remote access dial-up functionality.
Syntax
DisplayString (SIZE (0..63))
Access
Read-write
Remote Dial-Up Modem Baud Rate
Name
remoteDialUpModemBaudRate
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.13
Description
Defines the baud rate for the modem used by this remote access
dial-up functionality.
Syntax
DellUnsigned32BitRange
Access
Read-write
Remote Access Group
505
book.book Page 506 Wednesday, March 6, 2013 12:37 AM
Remote Dial-Up Modem Port
Name
remoteDialUpModemPort
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.14
Description
Defines the port for the modem used by this remote access dialup functionality.
Syntax
DellUnsigned32BitRange
Access
Read-write
Remote User Dial-In Configuration Table
Name
remoteUserDialInCfgTable
Object ID
1.3.6.1.4.1.674.10892.1.1700.50
Description
Defines the Remote Access User Dial-In Configuration Table.
Syntax
SEQUENCE OF RemoteUserDialInCfgTableEntry
Access
Not accessible
Remote User Dial-In Configuration Table Entry
Name
remoteUserDialInCfgTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1700.50.1
Description
Defines the Remote Access User Dial-In Configuration Table
entry.
Syntax
RemoteUserDialInCfgTableEntry
Access
Not accessible
Index
remoteUserDialInCfgChassisIndex,
remoteUserDialInCfgAdapterIndex,
remoteUserDialInCfgUserIndex
506
Remote Access Group
book.book Page 507 Wednesday, March 6, 2013 12:37 AM
Remote User Dial-In Configuration Chassis Index
Name
remoteUserDialInCfgChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.50.1.1
Description
Defines the index (one-based) of the chassis containing the
remote access hardware.
Syntax
DellObjectRange
Access
Read-only
Remote User Dial-In Configuration Adapter Index
Name
remoteUserDialInCfgAdapterIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.50.1.2
Description
Defines the index (one-based) of the remote access hardware
that supports this remote access dial-in user.
Syntax
DellObjectRange
Access
Read-only
Remote User Dial-In Configuration User Index
Name
remoteUserDialInCfgUserIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.50.1.3
Description
Defines the index (one-based) of this remote access dial-in user.
Syntax
DellObjectRange
Access
Read-only
Remote User Dial-In Configuration State Capabilities
Name
remoteUserDialInCfgStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.50.1.4
Description
Defines the state capabilities of this remote access dial-in user.
Syntax
DellRemoteUserDialInStateCapabilities (See Table 19-25)
Access
Read-only
Remote Access Group
507
book.book Page 508 Wednesday, March 6, 2013 12:37 AM
Remote User Dial-In Configuration State Settings
Name
remoteUserDialInCfgStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.50.1.5
Description
Defines the state settings of this remote access dial-in user.
Syntax
DellRemoteUserDialInStateSettings (See Table 19-26)
Access
Read-write
Remote User Dial-In Configuration Status
Name
remoteUserDialInCfgStatus
Object ID
1.3.6.1.4.1.674.10892.1.1700.50.1.6
Description
Defines the status of this remote access dial-in user.
Syntax
DellStatus
Access
Read-only
Remote User Dial-In Configuration PPP Username
Name
remoteUserDialInCfgPPPUserName
Object ID
1.3.6.1.4.1.674.10892.1.1700.50.1.7
Description
Defines the PPP user name of this remote access dial-in user.
Syntax
DisplayString (SIZE (0..15))
Access
Read-write
Remote User Dial-In Configuration PPP User Password Name
Name
remoteUserDialInCfgPPPUserPasswordName
Object ID
1.3.6.1.4.1.674.10892.1.1700.50.1.8
Description
Defines the PPP password of this remote access dial-in user.
Syntax
DisplayString (SIZE (0..15))
Access
Read-write
508
Remote Access Group
book.book Page 509 Wednesday, March 6, 2013 12:37 AM
Remote User Dial-In Configuration Callback Phone Number Name
Name
remoteUserDialInCfgCallbackPhoneNumberName
Object ID
1.3.6.1.4.1.674.10892.1.1700.50.1.9
Description
Defines the callback phone number for this remote access dial-in user.
Syntax
DisplayString (SIZE (0..95))
Access
Read-write
Remote Dial-Out Table
Name
remoteDialOutTable
Object ID
1.3.6.1.4.1.674.10892.1.1700.60
Description
Defines the Remote Access Dial-Out Table.
Syntax
SEQUENCE of RemoteDialOutTableEntry
Access
Not accessible
Remote Dial-Out Table Entry
Name
remoteDialOutTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1700.60.1
Description
Defines the Remote Access Dial-Out Table entry.
Syntax
RemoteDialOutTableEntry
Access
Not accessible
Index
remoteDialOutChassisIndex, remoteDialOutAdapterIndex,
remoteDialOutDialOutIndex
Remote Dial-Out Chassis Index
Name
remoteDialOutChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.60.1.1
Description
Defines the index (one-based) of the chassis containing the
remote access hardware.
Syntax
DellObjectRange
Access
Read-only
Remote Access Group
509
book.book Page 510 Wednesday, March 6, 2013 12:37 AM
Remote Dial-Out Adapter Index
Name
remoteDialOutAdapterIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.60.1.2
Description
Defines the index (one-based) of the remote access hardware
that supports this remote access dial-out functionality.
Syntax
DellObjectRange
Access
Read-only
Remote Dial-Out Dial-Out Index
Name
remoteDialOutDialOutIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.60.1.3
Description
Defines the index (one-based) of this remote access dial-out
functionality.
Syntax
DellObjectRange
Access
Read-only
Remote Dial-Out State Capabilities
Name
remoteDialOutStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.60.1.4
Description
Defines the state capabilities of this remote access dial-out
functionality.
Syntax
DellRemoteDialOutStateCapabilities (See Table 19-27)
Access
Read-only
Remote Dial-Out State Settings
Name
remoteDialOutStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.60.1.5
Description
Defines the state settings of this remote access dial-out functionality.
Syntax
DellRemoteDialOutStateSettings (See Table 19-28)
Access
Read-write
510
Remote Access Group
book.book Page 511 Wednesday, March 6, 2013 12:37 AM
Remote Dial-Out Status
Name
remoteDialOutStatus
Object ID
1.3.6.1.4.1.674.10892.1.1700.60.1.6
Description
Defines the status of this remote access dial-out functionality.
Syntax
DellStatus
Access
Read-only
Remote Dial-Out IP Address
Name
remoteDialOutIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.60.1.7
Description
Defines the IP address for this remote access dial-out
destination.
Syntax
IpAddress
Access
Read-write
Remote Dial-Out Phone Number Name
Name
remoteDialOutPhoneNumberName
Object ID
1.3.6.1.4.1.674.10892.1.1700.60.1.8
Description
Defines the phone number for this remote access dial-out
destination.
Syntax
DisplayString (SIZE (0..95))
Access
Read-write
Remote Dial-Out PPP Username
Name
remoteDialOutPPPUserName
Object ID
1.3.6.1.4.1.674.10892.1.1700.60.1.9
Description
Defines the PPP username for this remote access dial-out
destination.
Syntax
DisplayString (SIZE (0..31))
Access
Read-write
Remote Access Group
511
book.book Page 512 Wednesday, March 6, 2013 12:37 AM
Remote Dial-Out PPP Password Name
Name
remoteDialOutPPPPasswordName
Object ID
1.3.6.1.4.1.674.10892.1.1700.60.1.10
Description
Defines the PPP password for this remote access dial-out destination.
Syntax
DisplayString (SIZE (0..31))
Access
Read-write
Remote Access Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 19-1. Remote Access Type
Variable Name: DellRemoteAccessType
Data Type: Integer
Possible Data Values
Meaning of Data Value
remoteAccessTypeIsOther(1)
The remote access type is not one of
the following:
remoteAccessTypeIsUnknown(2) The remote access type is unknown.
remoteAccessTypeIsDRACIII(3) The remote access type is DRAC III.
remoteAccessTypeIsERA(4)
The remote access type is ERA.
Table 19-2. Remote Access Control Capabilities
Variable Name: DellRemoteAccessControlCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The remote access hardware has no
control capabilities.
unknownCapabilities(1)
The remote access hardware control
capabilities are unknown.
512
Remote Access Group
book.book Page 513 Wednesday, March 6, 2013 12:37 AM
Table 19-2.
Remote Access Control Capabilities (continued)
Variable Name: DellRemoteAccessControlCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
logResetCapable(2)
The remote access hardware can reset
its integrated logs.
hardResetCapable(4)
The remote access hardware can
perform a hard reset.
softResetCapable(8)
The remote access hardware can
perform a soft reset.
gracefulResetCapable(16)
The remote access hardware can
gracefully shut down and perform a
soft reset.
defaultConfigResetCapable(32) The remote access hardware can reset
to its default settings.
shutdownCapable(64)
Table 19-3.
The remote access hardware can
shut down.
Remote Access Control Settings
Variable Name: DellRemoteAccessControlSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The remote access hardware has no control settings.
unknown(1)
The remote access hardware control settings are
unknown.
logReset(2)
The remote access hardware resets its
integrated logs.
hardReset(4)
The remote access hardware performs a hard reset.
softReset(8)
The remote access hardware performs a soft reset.
gracefulReset(16)
The remote access hardware shuts down and
perform a soft reset.
Remote Access Group
513
book.book Page 514 Wednesday, March 6, 2013 12:37 AM
Table 19-3. Remote Access Control Settings (continued)
Variable Name: DellRemoteAccessControlSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
defaultConfigReset(32) The remote access hardware resets to its default
settings.
shutdown(64)
The remote access hardware shuts down.
Table 19-4. Remote Access Monitor Capabilities
Variable Name: DellRemoteAccessMonitorCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The remote access hardware has no
monitor capabilities.
unknownCapabilities(1)
The remote access hardware monitor
capabilities are unknown.
extPwrSupplyMonitorIfConn The remote access hardware can be set to
ectedCapable(2)
monitor the external power supply, if
connected.
extPwrSupplyMonitorAlways The remote access hardware can be set to
EnabledCapable(4)
always monitor the external power supply.
514
Remote Access Group
book.book Page 515 Wednesday, March 6, 2013 12:37 AM
Table 19-5.
Remote Access Monitor Settings
Variable Name: DellRemoteAccessMonitorSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The remote access hardware has no
monitor settings.
unknown(1)
The remote access hardware monitor settings
are unknown.
extPwrSupplyMonitorIfConn The remote access hardware monitors the
ectedEnabled(2)
external power supply, if connected.
extPwrSupplyMonitorAlways The remote access hardware always monitors
EnabledEnabled(4)
the external power supply.
Table 19-6.
Remote Access Local Area Network (LAN) Capabilities
Variable Name: DellRemoteAccessLANCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The remote access hardware has no
LAN capabilities.
unknownCapabilities(1)
The remote access hardware LAN capabilities
are unknown.
nicCapable(2)
The remote access hardware has a network
interface controller (NIC).
nicDHCPCapable(4)
The remote access hardware NIC can use
DHCP to obtain an IP address.
Remote Access Group
515
book.book Page 516 Wednesday, March 6, 2013 12:37 AM
Table 19-7. Remote Access LAN Settings
Variable Name: DellRemoteAccessLANSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The remote access hardware has no LAN
settings.
unknown(1)
The remote access hardware LAN settings are
unknown.
nicEnabled(2)
The remote access hardware NIC is enabled.
nicDHCPEnabled(4)
The remote access hardware NIC uses DHCP
to obtain an IP address.
Table 19-8. Remote Access Host Capabilities
Variable Name: DellRemoteAccessHostCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The remote access hardware has no
host capabilities.
unknownCapabilities(1)
The remote access hardware host
capabilities are unknown.
smtpEmailCapable(2)
The remote access hardware
supports sending e-mail using SMTP.
tftpRemoteFloppyCapable(4)
The remote access hardware supports
remote floppy boot using a TFTP server.
tftpRemoteFwUpdateCapable(8) The remote access hardware supports
remote firmware update using a TFTP
server.
516
Remote Access Group
book.book Page 517 Wednesday, March 6, 2013 12:37 AM
Table 19-9.
Remote Access Host Settings
Variable Name: DellRemoteAccessHostSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The remote access hardware has no host
settings.
unknown(1)
The remote access hardware host settings
are unknown.
smtpEmailEnabled(2)
The remote access hardware SMTP client
is enabled for sending e-mail.
tftpRemoteFloppyEnabled(4)
The remote access hardware TFTP client
is enabled for remote floppy boot.
tftpRemoteFwUpdateEnabled(8) The remote access hardware TFTP client
is enabled for remote firmware update.
Table 19-10. Remote Access Out-Of-Band Simple Network Management Protocol
(SNMP) Capabilities
Variable Name: DellRemoteAccessOutOfBandSNMPCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The remote access hardware has no out-of-band
SNMP capabilities.
unknownCapabilities(1) The remote access hardware out-of-band SNMP
capabilities are unknown.
oobSNMPAgentCapable(2) The remote access hardware has an out-of-band
SNMP agent.
oobSNMPTrapsCapable(4) The remote access hardware can send out-of-band
SNMP traps.
Remote Access Group
517
book.book Page 518 Wednesday, March 6, 2013 12:37 AM
Table 19-11. Remote Access Out-Of-Band Simple Network Management Protocol
(SNMP) Settings
Variable Name: DellRemoteAccessOutOfBandSNMPSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The remote access hardware has no out-of-band
SNMP settings.
unknown(1)
The remote access hardware out-of-band SNMP
settings are unknown.
oobSNMPAgentEnabled(2) The remote access hardware out-of-band SNMP
agent is enabled.
oobSNMPTrapsEnabled(4) The remote access hardware sends out-of-band
SNMP traps.
Table 19-12. Remote User Admin State Capabilities
Variable Name: DellRemoteUserAdminStateCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The admin user has no state capabilities.
unknownCapabilities(1) The admin user state capabilities are unknown.
enableCapable(2)
The admin user can be disabled or enabled.
notReadyCapable(4)
The admin user can be in the not ready state.
numericPagerCapable(8) The admin user supports numeric paging.
alphaPagerCapable(16)
The admin user supports alphanumeric paging.
emailCapable(32)
The admin user supports e-mail.
privilegeCapable(64)
The admin user supports user privileges
configuration.
518
Remote Access Group
book.book Page 519 Wednesday, March 6, 2013 12:37 AM
Table 19-13. Remote User Admin State Settings
Variable Name: DellRemoteUserAdminStateSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The admin user has no state settings.
unknown(1)
The admin user state settings are unknown.
enabled(2)
The admin user is enabled.
notReady(4)
The admin user is in the not ready state.
numericPagerEnabled(8) Numeric paging is enabled for the admin user.
alphaPagerEnabled(16)
Alphanumeric paging is enabled for the admin
user.
emailEnabled(32)
E-mail is enabled for the admin user.
Table 19-14. Remote User Admin Control Capabilities
Variable Name: DellRemoteUserAdminControlCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The admin user has no control capabilities.
unknownCapabilities(1)
The admin user control capabilities are
unknown.
numericPagerTestCapable(2) The admin user can support sending a test
numeric page.
alphaPagerTestCapable(4)
The admin user can support sending a test
alphanumeric page.
emailTestCapable(8)
The admin user can support sending a test
e-mail.
Remote Access Group
519
book.book Page 520 Wednesday, March 6, 2013 12:37 AM
Table 19-15. Remote User Admin Control Settings
Variable Name: DellRemoteUserAdminControlSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The admin user has no control settings.
unknown(1)
The admin user control settings are unknown.
numericPagerTest(2) A numeric pager test is performed for the admin user.
alphaPagerTest(4)
An alphanumeric pager test is performed for the
admin user.
emailTest(8)
An e-mail test is performed for the admin user.
Table 19-16. Remote User Admin Alpha Protocol Type
Variable Name: DellRemoteUserAdminAlphaProtocolType
Data Type: Integer
Possible Data Values
Meaning of Data Value
other(1)
The remote user admin alpha protocol type is not one
of the following:
unknown(2)
The remote user admin alpha protocol type is
unknown.
alpha7E0(3)
The remote user admin alpha protocol type is 7E0.
alpha8N1(4)
The remote user admin alpha protocol type is 8N1.
520
Remote Access Group
book.book Page 521 Wednesday, March 6, 2013 12:37 AM
Table 19-17. Remote User Admin Alpha Baud Type
Variable Name: DellRemoteUserAdminAlphaBaudType
Data Type: Integer
Possible Data Values
Meaning of Data Value
other(1)
The remote user alphanumeric baud rate is not one
of the following:
unknown(2)
The remote user alphanumeric baud rate is unknown.
alphaBaud300(3)
The remote user alphanumeric baud rate is 300.
alphaBaud1200(4)
The remote user alphanumeric baud rate is 1200.
Table 19-18. Remote SNMP Trap State Capabilities
Variable Name: DellRemoteSNMPTrapStateCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The SNMP trap destination has no state capabilities.
unknownCapabilities The SNMP trap destination state capabilities
(1)
are unknown.
enableCapable(2)
The SNMP trap destination can be disabled or enabled.
notReadyCapable(4)
The SNMP trap destination can be in the not ready
state.
Table 19-19. Remote SNMP Trap State Settings
Variable Name: DellRemoteSNMPTrapStateSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The SNMP trap destination has no state settings.
unknown(1)
The SNMP trap destination state settings are unknown.
enabled(2)
The SNMP trap destination is enabled.
notReady(4)
The SNMP trap destination is in the not ready state.
Remote Access Group
521
book.book Page 522 Wednesday, March 6, 2013 12:37 AM
Table 19-20. Remote SNMP Trap Control Capabilities
Variable Name: DellRemoteSNMPTrapControlCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The SNMP trap destination has no control capabilities.
unknownCapabilities The SNMP trap destination control capabilities are
(1)
unknown.
trapTestCapable(2)
A SNMP trap test can be performed for the SNMP trap
destination.
Table 19-21. Remote SNMP Trap Control Settings
Variable Name: DellRemoteSNMPTrapControlSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The SNMP trap destination has no control settings.
unknown(1)
The SNMP trap destination control settings are
unknown.
trapTestCapable(2)
A SNMP trap test is performed for the SNMP trap
destination.
Table 19-22. Remote Dial-Up State Capabilities
Variable Name: DellRemoteDialUpStateCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The dial-up functionality has no
state capabilities.
unknownCapabilities(1)
The dial-up functionality state
capabilities are unknown.
enableCapable(2)
The dial-up functionality can be
disabled or enabled.
522
Remote Access Group
book.book Page 523 Wednesday, March 6, 2013 12:37 AM
Table 19-22. Remote Dial-Up State Capabilities (continued)
Variable Name: DellRemoteDialUpStateCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
notReadyCapable(4)
The dial-up functionality can be in
the not ready state.
dialInCapable(8)
The dial-up functionality can
support the dial-in feature.
dialOutCapable(16)
The dial-up functionality can
support the dial-out feature.
dialInDHCPCapable(32)
The dial-up functionality can
support using DHCP to obtain an
IP address for the dial-in feature.
dialInAuthAnyCapable(64)
The dial-up functionality can support
any authentication type (including
clear text) for the dial-in feature.
dialInAuthEncryptedCapable(128) The dial-up functionality can support
encrypted passwords (CHAP)
authentication for the dial-in feature.
dialInAuthMschapCapable(256)
The dial-up functionality can
support MSCHAP authentication
type for the dial-in feature.
Table 19-23. Remote Dial-Up State Settings
Variable Name: DellRemoteDialUpStateSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The dial-up functionality has no state settings.
unknown(1)
The dial-up functionality state settings are unknown.
enabled(2)
The dial-up functionality is enabled.
notReadyCapable(4)
The dial-up functionality is in the not ready state.
dialInEnabled(8)
The dial-up functionality dial-in feature is enabled.
dialOutEnabled(16)
The dial-up functionality dial-out feature is enabled.
Remote Access Group
523
book.book Page 524 Wednesday, March 6, 2013 12:37 AM
Table 19-23. Remote Dial-Up State Settings (continued)
Variable Name: DellRemoteDialUpStateSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
dialInDHCPEnabled(32) The dial-up functionality uses DHCP to obtain an IP
address for the dial-in feature.
dialInAuthAnyEnabled The dial-up functionality accepts any authentication
(64)
type (including clear text) for the dial-in feature.
dialInAuthEncrypted The dial-up functionality uses only encrypted
Enabled(128)
passwords (CHAP) authentication type for the dialin feature.
dialInAuthMschapEnab The dial-up functionality uses only MSCHAP
led(256)
authentication type for the dial-in feature.
Table 19-24. Remote Dial-Up Modem Dial Type
Variable Name: DellRemoteDialUpModemDialType
Data Type: Integer
Possible Data Values
Meaning of Data Value
remoteDialUpIsOther(1)
The remote dial type is not one of the
following:
remoteDialUpIsUnknown(2)
The remote dial type is unknown.
remoteDialUpIsTone(3)
The remote dial type is tone.
remoteDialUpIsPulse(4)
The remote dial type is pulse.
524
Remote Access Group
book.book Page 525 Wednesday, March 6, 2013 12:37 AM
Table 19-25. Remote User Dial-In State Capabilities
Variable Name: DellRemoteUserDialInStateCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The dial-in user has no state capabilities.
unknownCapabilities(1)
The dial-in user state capabilities are
unknown.
enableCapable(2)
The dial-in user can be disabled or
enabled.
notReadyCapable(4)
The dial-in user can be in the not ready
state.
dialInCallbackPresetNumber The dial-in user can support callback
Capable(8)
using a preset number.
dialInCallbackUserSpecified The dial-in user can support callback
Capable(16)
using a user-specified number.
Table 19-26. Remote User Dial-In State Settings
Variable Name: DellRemoteUserDialInStateSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The dial-in user has no state settings.
unknown(1)
The dial-in user state settings are
unknown.
enabled(2)
The dial-in user is enabled.
notReady(4)
The dial-in user is in the not ready state.
dialInCallbackPresetNumber Callback using a preset number is
Enabled(8)
enabled for the dial-in user.
dialInCallbackUserSpecified Callback using a user-specified number is
Enabled(16)
enabled for the dial-in user.
Remote Access Group
525
book.book Page 526 Wednesday, March 6, 2013 12:37 AM
Table 19-27. Remote Dial-Out State Capabilities
Variable Name: DellRemoteDialOutStateCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The dial-out destination has no
state capabilities.
unknownCapabilities(1)
The dial-out destination state
capabilities are unknown.
enableCapable(2)
The dial-out destination can be
disabled or enabled.
notReadyCapable(4)
The dial-out destination can be
in the not ready state.
dialOutPPPAuthAnyCapable(8)
The dial-out destination can
support any authentication type
(including clear text) for PPP.
dialOutPPPAuthEncryptedCapable(16) The dial-out destination can
support encrypted passwords
authentication type for PPP.
dialOutPPPAuthMschapCapable(32)
526
Remote Access Group
The dial-out destination can
support MSCHAP
authentication type for PPP.
book.book Page 527 Wednesday, March 6, 2013 12:37 AM
Table 19-28. Remote Dial-Out State Settings
Variable Name: DellRemoteDialOutStateSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The dial-out destination has no
state settings.
unknown(1)
The dial-out destination state
settings are unknown.
enabled(2)
The dial-out destination is
disabled or enabled.
notReady(4)
The dial-out destination is in the
not ready state.
dialOutPPPAuthAnyEnabled(8)
The dial-out destination accepts
any authentication type
(including clear text) for PPP.
dialOutPPPAuthEncryptedEnabled(16) The dial-out destination uses only
encrypted passwords
authentication type for PPP.
dialOutPPPAuthMschapEnabled(32)
The dial-out destination uses only
MSCHAP authentication type for
PPP.
Remote Access Group
527
book.book Page 528 Wednesday, March 6, 2013 12:37 AM
528
Remote Access Group
book.book Page 529 Wednesday, March 6, 2013 12:37 AM
20
Cluster Group
Clustering combines multiple systems in such a way that they provide services a
single system cannot. Clustering enhances higher availability, scalability,
and management. Higher availability is achieved by using failover clusters,
in which resources can automatically move between two or more systems in the
event of a failure. Scalability is achieved by balancing the load of an application
across several computer systems. Simpler management is achieved by using
virtual servers, as opposed to managing each individual computer system.
Cluster Group
The Cluster Group defines attributes such as the number of systems in the
cluster, capabilities of the cluster, type of cluster, and name of the cluster.
Cluster Table
The following table defines the attributes of the cluster.
Name
clusterTable
Object ID
1.3.6.1.4.1.674.10892.1.1800.10
Description
Defines the Cluster Table.
Syntax
SEQUENCE OF ClusterTableEntry
Access
Not accessible
Cluster Table Entry
Name
clusterTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1800.10.1
Description
Defines the Cluster Table entry.
Syntax
ClusterTableEntry
Access
Not accessible
Index
clusterChassisIndex, clusterIndex
Cluster Group
529
book.book Page 530 Wednesday, March 6, 2013 12:37 AM
Cluster Chassis Index
Name
clusterChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1800.10.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Cluster Index
Name
clusterIndex
Object ID
1.3.6.1.4.1.674.10892.1.1800.10.1.2
Description
Defines the index (one-based) of the cluster.
Syntax
DellObjectRange
Access
Read-only
Cluster State Capabilities
Name
clusterStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1800.10.1.3
Description
Defines the state capabilities of the cluster.
Syntax
DellStateCapabilities
Access
Read-only
Cluster State Settings
Name
clusterStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1800.10.1.4
Description
Defines the state settings of the cluster.
Syntax
DellStateSettings
Access
Read-write
530
Cluster Group
book.book Page 531 Wednesday, March 6, 2013 12:37 AM
Cluster Status
Name
clusterStatus
Object ID
1.3.6.1.4.1.674.10892.1.1800.10.1.5
Description
Defines the status of the cluster.
Syntax
DellStatus
Access
Read-only
Cluster Type
Name
clusterType
Object ID
1.3.6.1.4.1.674.10892.1.1800.10.1.6
Description
Defines the type of the cluster.
Syntax
DellClusterType
Access
Read-only
Cluster Type Description Name
Name
clusterTypeDescriptionName
Object ID
1.3.6.1.4.1.674.10892.1.1800.10.1.7
Description
Defines the description name for the type of the cluster.
Syntax
DellString
Access
Read-only
Cluster Name
Name
clusterName
Object ID
1.3.6.1.4.1.674.10892.1.1800.10.1.8
Description
Defines the name of the cluster.
Syntax
DellString
Access
Read-only
Cluster Group
531
book.book Page 532 Wednesday, March 6, 2013 12:37 AM
Cluster Group Variable Values
This section includes definitions for Server Administrator-specific variable
values used in this section.
Table 20-1. Cluster Type
Variable Name: DellClusterType
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
The cluster type is unknown.
highAvailabilityCluster(2) The cluster type is a high-availability cluster.
532
Cluster Group
book.book Page 533 Wednesday, March 6, 2013 12:37 AM
21
Baseboard Management Controller
Group
The Baseboard Management Controller (BMC) monitors the system for
critical events by communicating with various sensors on the system board
and sends alerts and log events when certain parameters exceed their preset
thresholds. The BMC Group provides information about the BMC that may
be present in your system. In addition to providing general information about
the BMC, this group provides information about the serial and local area
network (LAN) interfaces of the BMC.
Baseboard Management Controller Group Tables
The objects in the BMC group define information about the BMC and the
serial and LAN interfaces that can be used to access the BMC remotely to
perform management activities. Objects for the serial interface define the
serial connection mode, flow control type and bit rate. Objects for the LAN
interface define the media access control (MAC) address, internet protocol
(IP) address, subnet mask and default gateway.
The following MIB tables define the BMC group:
•
Baseboard Management Controller Table
•
Baseboard Management Controller Serial Interface Table
•
Baseboard Management Controller LAN Interface Table
Baseboard Management Controller Table
Name
bmcTable
Object ID
1.3.6.1.4.1.674.10892.1.1900.10
Description
Defines the Baseboard Management Controller Table.
Syntax
SEQUENCE OF BmcTableEntry
Access
Not accessible
Baseboard Management Controller Group
533
book.book Page 534 Wednesday, March 6, 2013 12:37 AM
BMC Table Entry
Name
bmcTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1900.10.1
Description
Defines the Baseboard Management Controller (BMC) Table Entry.
Syntax
BmcTableEntry
Access
Not accessible
Index
bmcChassisIndex, bmcIndex
BMC Chassis Index
Name
bmcChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1900.10.1.1
Description
Defines the index (one-based) of the associated chassis.
Syntax
DellObjectRange
Access
Read-only
BMC Index
Name
bmcIndex
Object ID
1.3.6.1.4.1.674.10892.1.1900.10.1.2
Description
Defines the index (one-based) of the BMC.
Syntax
DellObjectRange
Access
Read-only
BMC State Capabilities
Name
bmcStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1900.10.1.3
Description
Defines the state capabilities of the BMC.
Syntax
DellStateCapabilities
Access
Read-only
534
Baseboard Management Controller Group
book.book Page 535 Wednesday, March 6, 2013 12:37 AM
BMC State Settings
Name
bmcStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1900.10.1.4
Description
Defines the state settings of the BMC.
Syntax
DellStateSettings
Access
Read-write
BMC Status
Name
bmcStatus
Object ID
1.3.6.1.4.1.674.10892.1.1900.10.1.5
Description
Defines the status of the BMC.
Syntax
DellStatus
Access
Read-only
BMC Display Name
Name
bmcDisplayName
Object ID
1.3.6.1.4.1.674.10892.1.1900.10.1.6
Description
Defines the display name of the BMC.
Syntax
DellString
Access
Read-only
BMC Description Name
Name
bmcDescriptionName
Object ID
1.3.6.1.4.1.674.10892.1.1900.10.1.7
Description
Defines the description of the BMC.
Syntax
DisplayString (SIZE (0..255))
Access
Read-only
Baseboard Management Controller Group
535
book.book Page 536 Wednesday, March 6, 2013 12:37 AM
BMC IPMI Version Name
Name
bmcIPMIVersionName
Object ID
1.3.6.1.4.1.674.10892.1.1900.10.1.8
Description
Defines the version of the Intelligent Platform Management
Interface (IPMI) specification that the BMC supports.
Syntax
DellString
Access
Read-only
BMC GUID
Name
bmcGUID
Object ID
1.3.6.1.4.1.674.10892.1.1900.10.1.9
Description
Defines the Globally Unique ID (GUID) of the BMC.
Syntax
Octet String (SIZE(16))
Access
Read-only
BMC Type
Name
bmcType
Object ID
1.3.6.1.4.1.674.10892.1.1900.10.1.10
Description
Defines the type of the BMC.
Syntax
DellManagementControllerType
Access
Read-only
BMC Module Name
Name
bmcModuleName
Object ID
1.3.6.1.4.1.674.10892.1.1900.10.1.11
Description
Defines the module name for the BMC. The module name is
present only on certain systems, such as modular systems.
Syntax
DellString
Access
Read-only
536
Baseboard Management Controller Group
book.book Page 537 Wednesday, March 6, 2013 12:37 AM
BMC IPv4 URL Name
Name
bmcIPv4URLName
Object ID
1.3.6.1.4.1.674.10892.1.1900.10.1.12
Description
Defines the IPv4 URL for the BMC. The URL is not present on
all systems.
Syntax
DisplayString (SIZE (0..1024))
Access
Read-only
BMC IPv6 URL Name
Name
bmcIPv6URLName
Object ID
1.3.6.1.4.1.674.10892.1.1900.10.1.13
Description
Defines the IPv6 URL for the BMC. The URL is not present on
all systems.
Syntax
DisplayString (SIZE (0..1024))
Access
Read-only
Baseboard Management Controller Serial Interface Table
Name
bmcSerialInterfaceTable
Object ID
1.3.6.1.4.1.674.10892.1.1900.20
Description
Defines the BMC Serial Interface Table.
Syntax
SEQUENCE OF BmcSerialInterfaceTableEntry
Access
Not accessible
Baseboard Management Controller Group
537
book.book Page 538 Wednesday, March 6, 2013 12:37 AM
BMC Serial Interface Table Entry
Name
bmcSerialInterfaceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1900.20.1
Description
Defines the BMC Serial Interface Table Entry.
Syntax
BmcSerialInterfaceTableEntry
Access
Not accessible
Index
bmcSerialInterfaceChassisIndex,
bmcSerialInterfaceBMCIndex, bmcSerialInterfaceIndex
BMC Serial Interface Chassis Index
Name
bmcSerialInterfaceChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1900.20.1.1
Description
Defines the index (one-based) of the associated chassis.
Syntax
DellObjectRange
Access
Read-only
BMC Serial Interface BMC Index
Name
bmcSerialInterfaceBMCIndex
Object ID
1.3.6.1.4.1.674.10892.1.1900.20.1.2
Description
Defines the index (one-based) of the associated BMC.
Syntax
DellObjectRange
Access
Read-only
BMC Serial Interface Index
Name
bmcSerialInterfaceIndex
Object ID
1.3.6.1.4.1.674.10892.1.1900.20.1.3
Description
Defines the index (one-based) of the BMC serial interface.
Syntax
DellObjectRange
Access
Read-only
538
Baseboard Management Controller Group
book.book Page 539 Wednesday, March 6, 2013 12:37 AM
BMC Serial Interface State Capabilities
Name
bmcSerialInterfaceStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1900.20.1.4
Description
Defines the state capabilities of the BMC serial interface.
Syntax
DellStateCapabilities
Access
Read-only
BMC Serial Interface State Settings
Name
bmcSerialInterfaceStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1900.20.1.5
Description
Defines the state settings of the BMC serial interface.
Syntax
DellStateSettings
Access
Read-write
BMC Serial Interface Status
Name
bmcSerialInterfaceStatus
Object ID
1.3.6.1.4.1.674.10892.1.1900.20.1.6
Description
Defines the status of the BMC serial interface.
Syntax
DellStatus
Access
Read-only
BMC Serial Interface Channel Number
Name
bmcSerialInterfaceChannelNumber
Object ID
1.3.6.1.4.1.674.10892.1.1900.20.1.7
Description
Defines the BMC channel number of the BMC serial interface.
Syntax
DellUnsigned8BitRange
Access
Read-only
Baseboard Management Controller Group
539
book.book Page 540 Wednesday, March 6, 2013 12:37 AM
BMC Serial Interface Connection Mode Capabilities
Name
bmcSerialInterfaceConnectionModeCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1900.20.1.8
Description
Defines the connection mode capabilities of the BMC serial
interface.
Syntax
DellBMCSerialConnectionModeCapabilities
Access
Read-only
BMC Serial Interface Connection Mode Settings
Name
bmcSerialInterfaceConnectionModeSettings
Object ID
1.3.6.1.4.1.674.10892.1.1900.20.1.9
Description
Defines the connection mode settings of the BMC serial
interface.
Syntax
DellBMCSerialConnectionModeSettings
Access
Read-only
BMC Serial Interface Flow Control
Name
bmcSerialInterfaceFlowControl
Object ID
1.3.6.1.4.1.674.10892.1.1900.20.1.10
Description
Defines the flow control type of the BMC serial interface.
Syntax
DellBMCSerialFlowControlType
Access
Read-only
BMC Serial Interface Bit Rate
Name
bmcSerialInterfaceBitRate
Object ID
1.3.6.1.4.1.674.10892.1.1900.20.1.11
Description
Defines the bit rate of the BMC serial interface.
Syntax
DellBMCSerialBitRateType
Access
Read-only
540
Baseboard Management Controller Group
book.book Page 541 Wednesday, March 6, 2013 12:37 AM
Baseboard Management Controller LAN Interface Table
Name
bmcLANInterfaceTable
Object ID
1.3.6.1.4.1.674.10892.1.1900.30
Description
Defines the Baseboard Management Controller (BMC) LAN
Interface Table.
Syntax
SEQUENCE OF BmcLANInterfaceTableEntry
Access
Not accessible
BMC LAN Interface Table Entry
Name
bmcLANInterfaceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1
Description
Defines the Baseboard Management Controller (BMC) LAN
Interface Table Entry.
Syntax
BmcLANInterfaceTableEntry
Access
Not accessible
Index
bmcLANInterfaceChassisIndex, bmcLANInterfaceBMCIndex,
bmcLANInterfaceIndex
BMC LAN Interface Chassis Index
Name
bmcLANInterfaceChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1.1
Description
Defines the index (one-based) of the associated chassis.
Syntax
DellObjectRange
Access
Read-only
Baseboard Management Controller Group
541
book.book Page 542 Wednesday, March 6, 2013 12:37 AM
BMC LAN Interface BMC Index
Name
bmcLANInterfaceBMCIndex
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1.2
Description
Defines the index (one-based) of the associated BMC.
Syntax
DellObjectRange
Access
Read-only
BMC LAN Interface Index
Name
bmcLANInterfaceIndex
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1.3
Description
Defines the index (one-based) of the BMC LAN interface.
Syntax
DellObjectRange
Access
Read-only
BMC LAN Interface State Capabilities
Name
bmcLANInterfaceStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1.4
Description
Defines the state capabilities of the BMC LAN interface.
Syntax
DellStateCapabilities
Access
Read-only
BMC LAN Interface State Settings
Name
bmcLANInterfaceStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1.5
Description
Defines the state settings of the BMC LAN interface.
Syntax
DellStateSettings
Access
Read-write
542
Baseboard Management Controller Group
book.book Page 543 Wednesday, March 6, 2013 12:37 AM
BMC LAN Interface Status
Name
bmcLANInterfaceStatus
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1.6
Description
Defines the status of the BMC LAN interface.
Syntax
DellStatus
Access
Read-only
BMC LAN Interface Channel Number
Name
bmcLANInterfaceChannelNumber
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1.7
Description
Defines the BMC channel number of the BMC LAN interface.
Syntax
DellUnsigned8BitRange
Access
Read-only
BMC LAN Interface IP Address Source
Name
bmcLANInterfaceIPAddressSource
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1.8
Description
Defines the source type of the IP address of the BMC LAN
interface.
Syntax
DellBMCLANIPAddressSourceType
Access
Read-only
BMC LAN Interface IP Address
Name
bmcLANInterfaceIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1.9
Description
Defines the IP address of the BMC LAN interface.
Syntax
IpAddress
Access
Read-only
Baseboard Management Controller Group
543
book.book Page 544 Wednesday, March 6, 2013 12:37 AM
BMC LAN Interface Subnet Mask Address
Name
bmcLANInterfaceSubnetMaskAddress
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1.10
Description
Defines the subnet mask of the BMC LAN interface.
Syntax
IpAddress
Access
Read-only
BMC LAN Interface Default Gateway Address
Name
bmcLANInterfaceDefaultGatewayAddress
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1.11
Description
Defines the IP address of the default gateway for the BMC LAN
interface.
Syntax
IpAddress
Access
Read-only
BMC LAN Interface MAC Address
Name
bmcLANInterfaceMACAddress
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1.12
Description
Defines the MAC address of the BMC LAN interface.
Syntax
DellMACAddress
Access
Read-only
BMC LAN Interface Alert Community Name
Name
bmcLANInterfaceAlertCommunityName
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1.13
Description
Defines the SNMP community used for BMC LAN alerts
(traps) sent on the BMC LAN interface.
Syntax
DisplayString (SIZE (0..32))
Access
Read-only
544
Baseboard Management Controller Group
book.book Page 545 Wednesday, March 6, 2013 12:37 AM
Baseboard Management Controller Group
Variable Values
This section includes definitions for server administrator-specific variable
values used in this section.
Table 21-1.
BMC Serial Connection Mode Capabilities
Variable Name: DellBMCSerialConnectionModeCapabilities
Data Type: Integer
These values are bit masks; therefore, combination values are possible.
Possible Data Values
Meaning of Data Value
-- none(0)
No mode capabilities.
modemBasic(1)
BMC serial interface supports Modem Basic mode.
modemPPP(2)
BMC serial interface supports Modem Point to Point
Protocol (PPP) mode.
modemTerminal(4)
BMC serial interface supports Modem Terminal mode.
directBasic(8)
BMC serial interface supports Direct Basic mode.
directPPP(16)
BMC serial interface supports Direct PPP mode.
directTerminal(32)
BMC serial interface supports Direct Terminal mode.
Table 21-2.
BMC Serial Connection Mode Settings
Variable Name: DellBMCSerialConnectionModeSettings
Data Type: Integer
These values are bit masks; therefore, combination values are possible.
Possible Data Values
Meaning of Data Value
-- none(0)
No modes enabled.
modemBasic(1)
Modem Basic mode is enabled.
modemPPP(2)
Modem PPP mode is enabled.
modemTerminal(4)
Modem Terminal mode is enabled.
directBasic(8)
Direct Basic mode is enabled.
directPPP(16)
Direct PPP mode is enabled.
directTerminal(32)
Direct Terminal mode is enabled.
Baseboard Management Controller Group
545
book.book Page 546 Wednesday, March 6, 2013 12:37 AM
Table 21-3. BMC Serial Flow Control Type
Variable Name: DellBMCSerialFlowControlType
Data Type: Integer
Possible Data Values
Meaning of Data Value
-- none(0)
No flow control used.
rtscts(1)
RTS/CTS (hardware) flow control used.
xonXoff(2)
XON/XOFF flow control used.
Table 21-4. BMC Serial Bit Rate Type
Variable Name: DellBMCSerialBitRateType
Data Type: Integer
Possible Data Values
Meaning of Data Value
bps9600(6)
Bit rate is 9600 bps (bits per second)
bps19200(7)
Bit rate is 19200 bps
bps38400(8)
Bit rate is 38400 bps
bps57600(9)
Bit rate is 57600 bps
bps115200(10)
Bit rate is 115200 bps
Table 21-5. BMC LAN IP Address Source Type
Variable Name: DellBMCLANIPAddressSourceType
Data Type: Integer
Possible Data Values
Meaning of Data Value
-- unspecified(0)
Source is unspecified.
static(1)
IP address is static.
dhcp(2)
Dynamic Host Configuration Protocol (DHCP)
used to obtain IP address.
biosOrSystemSoftware(3) BIOS or system software provided IP Address.
other(4)
546
Other protocol used to obtain IP address.
Baseboard Management Controller Group
book.book Page 547 Wednesday, March 6, 2013 12:37 AM
Table 21-6.
BMC Management Controller Type
Variable Name: DellManagementControllerType
Data Type: Integer
Possible Data Values
Meaning of Data Value
-- legacyBMC(0)
Controller type is legacy Baseboard
Management Controller.
iDRAC(8)
Controller type is iDRAC.
iDRAC6(10)
Controller type is Integrated Dell Remote
Access Controller 6.
iDRAC6Modular(11)
Controller type is Integrated Dell Remote
Access Controller 6 (Modular).
iDRAC6BMC(13)
Controller type is Integrated Dell Remote
Access Controller 6 (BMC mode).
iDRAC7(16)
Controller type is Integrated Dell Remote
Access Controller 7.
iDRAC7Modular(17)
Controller type is Integrated Dell Remote
Access Controller 7 (Modular).
Baseboard Management Controller Group
547
book.book Page 548 Wednesday, March 6, 2013 12:37 AM
548
Baseboard Management Controller Group
book.book Page 549 Wednesday, March 6, 2013 12:37 AM
22
Field Replaceable Unit Group
A field replaceable unit (FRU) is a part that can be removed and replaced
without having to send the system to a repair facility. The Field Replaceable
Unit Group provides information about the field replaceable units that may
be present in your system.
Field Replaceable Unit Group Tables
The objects in the FRU group define information such as manufacturer,
serial number, part number and revision for field replaceable units.
The following MIB tables define the FRU group.
Field Replaceable Unit Table
Name
fruTable
Object ID
1.3.6.1.4.1.674.10892.1.2000.10
Description
Defines the Field Replaceable Unit table.
Syntax
SEQUENCE OF FruTableEntry
Access
Not accessible
FRU Table Entry
Name
fruTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.2000.10.1
Description
Defines the FRU Table Entry.
Syntax
FruTableEntry
Access
Not accessible
Index
fruChassisIndex, fruIndex
Field Replaceable Unit Group
549
book.book Page 550 Wednesday, March 6, 2013 12:37 AM
FRU Chassis Index
Name
fruChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.2000.10.1.1
Description
Defines the index (one-based) of the chassis containing the
FRU.
Syntax
DellObjectRange
Access
Read-only
FRU Index
Name
fruIndex
Object ID
1.3.6.1.4.1.674.10892.1.2000.10.1.2
Description
Defines the index (one-based) of the FRU.
Syntax
DellObjectRange
Access
Read-only
FRU Information Status
Name
fruInformationStatus
Object ID
1.3.6.1.4.1.674.10892.1.2000.10.1.3
Description
Defines the status of the FRU table entry.
Syntax
DellStatus
Access
Read-only
FRU Information State
Name
fruInformationState
Object ID
1.3.6.1.4.1.674.10892.1.2000.10.1.4
Description
Defines the state of the FRU information. Some information for
the FRU may not be available if the state is other than ok(1).
Syntax
DellFRUInformationState
Access
Read-only
550
Field Replaceable Unit Group
book.book Page 551 Wednesday, March 6, 2013 12:37 AM
FRU Device Name
Name
fruDeviceName
Object ID
1.3.6.1.4.1.674.10892.1.2000.10.1.5
Description
Defines the device name of the FRU.
Syntax
DisplayString (SIZE (0..64))
Access
Read-only
FRU Manufacturer Name
Name
fruManufacturerName
Object ID
1.3.6.1.4.1.674.10892.1.2000.10.1.6
Description
Defines the manufacturer of the FRU.
Syntax
DisplayString (SIZE (0..64))
Access
Read-only
FRU Serial Number Name
Name
fruSerialNumberName
Object ID
1.3.6.1.4.1.674.10892.1.2000.10.1.7
Description
Defines the serial number of the FRU.
Syntax
DisplayString (SIZE (0..64))
Access
Read-only
FRU Part Number Name
Name
fruPartNumberName
Object ID
1.3.6.1.4.1.674.10892.1.2000.10.1.8
Description
Defines the part number of the FRU
Syntax
DisplayString (SIZE (0..64))
Access
Read-only
Field Replaceable Unit Group
551
book.book Page 552 Wednesday, March 6, 2013 12:37 AM
FRU Revision Name
Name
fruRevisionName
Object ID
1.3.6.1.4.1.674.10892.1.2000.10.1.9
Description
Defines the revision of the FRU.
Syntax
DisplayString (SIZE (0..64))
Access
Read-only
FRU Manufacturing Date Name
Name
fruManufacturingDateName
Object ID
1.3.6.1.4.1.674.10892.1.2000.10.1.10
Description
Defines the manufacturing date of the FRU.
Syntax
DellDateName
Access
Read-only
FRU Asset Tag Name
Name
fruAssetTagName
Object ID
1.3.6.1.4.1.674.10892.1.2000.10.1.11
Description
Defines the asset tag of the FRU.
Syntax
DisplayString (SIZE (0..64))
Access
Read-only
552
Field Replaceable Unit Group
book.book Page 553 Wednesday, March 6, 2013 12:37 AM
Field Replaceable Unit Group Variable Values
This section includes definitions for server administrator-specific variable
values.
Table 22-1.
FRU Information State
Variable Name: DellFRUInformationState
Data Type: Integer
Possible Data Values
Meaning of Data Value
ok(1)
FRU information is okay.
notSupported(2)
FRU information is not supported.
notAvailable(3)
FRU information is not available.
checksumInvalid(4)
FRU information checksum is invalid.
corrupted(5)
FRU information is corrupted.
Field Replaceable Unit Group
553
book.book Page 554 Wednesday, March 6, 2013 12:37 AM
554
Field Replaceable Unit Group
book.book Page 555 Wednesday, March 6, 2013 12:37 AM
Storage Management Group
23
The Storage Management Group is composed of the following:
•
Storage Management Group—information about the software product
and system status.
•
Storage Management Information Group—properties about the Simple
Network Management Protocol (SNMP) agent.
•
Global Data Group—system status.
•
Physical Devices Group—physical devices managed by the software.
•
Logical Devices Group—logical devices managed by the software.
•
Storage Management Event Group—SNMP traps.
Storage Management Group
The Storage Management Information Base (MIB) Group defines the
properties that identify information about the Storage Management software
product and the current status of the system it manages.
Software Version
Name
softwareVersion
Object ID
1.3.6.1.4.1.674.10893.1.20.1
Description
Identifies the version of the storage management component of
the systems management software.
Syntax
DisplayString
Access
Read-only
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Template Last Updated - 2/7/2007
Storage Management Group
555
book.book Page 556 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Global Status
Name
globalStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.2
Description
Identifies the global health for the subsystem managed by the
Storage Management software. This global status is customized
for HP OpenView. Other applications should refer to the
agentSystemGlobalStatus entry in the globalData object group.
Possible values:
1: Critical
2: Warning
3: Normal
4: Unknown
Syntax
Integer
Access
Read-only
Software Manufacturer
Name
softwareManufacturer
Object ID
1.3.6.1.4.1.674.10893.1.20.3
Description
Identifies the manufacturer of the Storage Management software.
Syntax
DisplayString
Access
Read-only
Software Product
Name
softwareProduct
Object ID
1.3.6.1.4.1.674.10893.1.20.4
Description
Identifies product information for the Storage Management
software.
Syntax
DisplayString
Access
Read-only
Software Description
Name
softwareDescription
Object ID
1.3.6.1.4.1.674.10893.1.20.5
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
556
Storage Management Group
book.book Page 557 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Name
softwareDescription
Description
Identifies the product description for the Storage Management
software.
Syntax
DisplayString
Access
Read-only
Storage Management Information Group
The Storage Management Information Group defines the properties that
identify the Storage Management software SNMP agent.
Display Name
Name
displayName
Object ID
1.3.6.1.4.1.674.10893.1.20.100.1
Description
Identifies the name of this management software for display
purposes.
Syntax
DisplayString
Access
Read-only
Description
Name
description
Object ID
1.3.6.1.4.1.674.10893.1.20.100.2
Description
Provides a short description of this management software.
Syntax
DisplayString
Access
Read-only
Agent Vendor
Name
agentVendor
Object ID
1.3.6.1.4.1.674.10893.1.20.100.3
Description
Identifies the name of the management software manufacturer.
Syntax
DisplayString
Access
Read-only
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Storage Management Group
557
book.book Page 558 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Agent Version
Name
agentVersion
Object ID
1.3.6.1.4.1.674.10893.1.20.100.4
Description
This entry is obsolete. Refer to softwareVersion.
Syntax
DisplayString
Access
Read-only
Global Data Group
The Global Data Management Information Base (MIB) Group defines the
properties that identify status information about the system that the Storage
Management software is managing and about the Storage Management
SNMP agent.
Agent System Global Status
Name
agentSystemGlobalStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.110.1
Description
This entry is obsolete. Use the value agentGlobalSystemStatus.
Syntax
Integer
Access
Read-only
Agent Last Global Status
Name
agentLastGlobalStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.110.2
Description
This entry is obsolete. Use the value
agentLastGlobalSystemStatus.
Syntax
Integer
Access
Read-only
Agent Time Stamp
Name
agentTimeStamp
Object ID
1.3.6.1.4.1.674.10893.1.20.110.3
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
558
Storage Management Group
book.book Page 559 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Name
agentTimeStamp
Description
Identifies the last time the agent values have been updated.
Universal time in seconds since UTC 1/1/70.
Syntax
Integer
Access
Read-only
Agent Get Timeout
Name
agentGetTimeout
Object ID
1.3.6.1.4.1.674.10893.1.20.110.4
Description
Indicates the suggested timeout value, in milliseconds, for how
long the SNMP getter should wait while attempting to poll the
SNMP agent.
Syntax
Integer
Access
Read-only
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Storage Management Group
559
book.book Page 560 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Agent Modifiers
Name
agentModifiers
Object ID
1.3.6.1.4.1.674.10893.1.20.110.5
Description
Identifies the agent functional modifiers. When Agent Modifier is
set, the modifier is active. Bit definitions:
Bit 3: agent in debug mode.
All other bits are product specific.
Syntax
Integer
Access
Read-only
Agent Refresh Rate
Name
agentRefreshRate
Object ID
1.3.6.1.4.1.674.10893.1.20.110.6
Description
Identifies the rate, given in seconds, at which the cached data for
SNMP is refreshed. The default value is 300 seconds, or 5 minutes.
Syntax
Integer
Access
Read-only
Agent Hostname
Name
agentHostname
Object ID
1.3.6.1.4.1.674.10893.1.20.110.7
Description
This entry is obsolete for Storage Management.
Syntax
DisplayString
Access
Read-only
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
560
Storage Management Group
book.book Page 561 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Agent IP Address
Name
agentIPAddress
Object ID
1.3.6.1.4.1.674.10893.1.20.110.8
Description
This entry is obsolete for Storage Management.
Syntax
DisplayString
Access
Read-only
Agent Software Status
Name
agentSoftwareStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.110.9
Description
This entry is obsolete for Storage Management.
Syntax
DisplayString
Access
Read-only
Agent SNMP Version
Name
agentSnmpVersion
Object ID
1.3.6.1.4.1.674.10893.1.20.110.10
Description
This entry is obsolete. Refer to 0001 softwareVersion.
Syntax
DisplayString
Access
Read-only
Agent MIB Version
Name
agentMibVersion
Object ID
1.3.6.1.4.1.674.10893.1.20.110.11
Description
Identifies the version of the Storage Management MIB.
Syntax
DisplayString
Access
Read-only
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Storage Management Group
561
book.book Page 562 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Agent Management Software URL Name
Name
agentManagementSoftwareURLName
Object ID
1.3.6.1.4.1.674.10893.1.20.110.12
Description
Identifies the Universal Resource Locator (URL) of the systems
management software.
Syntax
DisplayString
Access
Read-only
Agent Global System Status
Name
agentGlobalSystemStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.110.13
Description
Identifies the global health information for the subsystem
managed by the Storage Management software. This is a rollup for
the entire agent including any monitored devices. The status is
intended to give initiative to an SNMP monitor to get further data
when this status is abnormal. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
NOTE: This global status should be used by applications other
than HP OpenView. HP OpenView should refer to the
globalStatus in the root level object group.
Syntax
DellStatus
Access
Read-only
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
562
Storage Management Group
book.book Page 563 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Agent Last Global System Status
Name
agentLastGlobalSystemStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.110.14
Description
Identifies the previous global status of the system managed by the
Storage Management software. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax
DellStatus
Access
Read-only
Agent Smart Thermal Shutdown
Name
agentSmartThermalShutdown
Object ID
1.3.6.1.4.1.674.10893.1.20.110.15
Description
Indicates the status of smart thermal shutdown for PowerVault
220S and PowerVault 221S enclosures.
Possible values:
1: Enabled
2: Disabled
3: Not applicable
Syntax
Integer
Access
Read-only
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Storage Management Group
563
book.book Page 564 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Physical Devices Group
The Physical Devices MIB group provides information about the devices
managed by the Storage Management software and their relationships to each
other. The following MIB tables define objects and relationships
(connections) among the objects.
•
Controller Table—describes available properties for each controller on the
managed system.
•
Channel Table—describes available properties for each channel on the
managed system.
•
Enclosure Table—describes available properties for each enclosure on the
managed system.
•
Array Disk Table—describes available properties for each physical array
disk on the managed system.
•
Array Disk Enclosure Connection Table—describes the connections
between Fibre Channel array disks, their enclosure, and their associated
controller. For each object in the table, its object number corresponds to an
instance number in the appropriate MIB table for that object where all of
the object properties can be found.
•
Array Disk Channel Connection Table—describes the connections
between SCSI array disks, their channel, and their associated controller.
For each object in the table, its object number corresponds to an instance
number in the appropriate MIB table for that object where all of the object
properties can be found.
•
Fan Table—describes available properties for each fan on the managed
system.
•
Fan Connection Table—describes the connection between each fan on
the managed system and its enclosure. Each enclosure number in the table
corresponds to that enclosure instance in the Enclosure Table.
•
Power Supply Table—describes available properties for each power supply
on the managed system.
•
Power Supply Connection Table—describes the connection between each
power supply on the managed system and its enclosure. Each enclosure
number in the table corresponds to that enclosure instance in the
Enclosure Table.
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
564
Storage Management Group
book.book Page 565 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
•
Temperature Probe Table—describes available properties for each
temperature probe on the managed system.
•
Temperature Probe Connection Table—describes the connection
between each temperature probe on the managed system and its
enclosure. Each enclosure number in the table corresponds to that
enclosure instance in the Enclosure Table.
•
EMM Table—describes available properties for each Enclosure
Management Module (EMM) on the managed system.
•
EMM Connection Table—describes the connection between each EMM
on the managed system and its enclosure. Each enclosure number in the
table corresponds to that enclosure instance in the Enclosure Table.
•
Battery Table—describes available properties for each controller battery on
the managed system.
•
Battery Connection Table—describes the connection between each
battery on the managed system and its controller. Each controller number
in the table corresponds to that controller instance in the Controller Table.
Controller Table
This table describes available properties for each controller on the managed
system.
The following object sets up the Controller Table.
Name
controllerTable
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1
Description
Defines the controller table, which is a table of managed
Redundant Array of Independent disks (RAID) controllers. The
number of entries is related to the number of RAID controllers
discovered by the system.
Syntax
SEQUENCE OF ControllerEntry
Access
Not accessible
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Storage Management Group
565
book.book Page 566 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Controller Entry
Name
controllerEntry
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1
Description
Defines the controller table entry, which is an entry in the table of
RAID controllers.
Syntax
ControllerEntry
Access
Not accessible
Index
controllerNumber
Controller Number
Name
controllerNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.1
Description
Identifies the instance number of the controller entry.
Syntax
Integer
Access
Read-only
Controller Name
Name
controllerName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.2
Description
Identifies the name of the controller in this subsystem as
represented in Storage Management. Includes the controller type
and instance. For example: PERC 3/QC 1.
Syntax
DisplayString
Access
Read-only
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
566
Storage Management Group
book.book Page 567 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Controller Vendor
Name
controllerVendor
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.3
Description
Identifies the controller's vendor's name.
Syntax
DisplayString
Access
Read-only
Controller Type
Name
controllerType
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.4
Description
Identifies the type of controller:
1: SCSI
2: PowerVault 660F
3: Power Vault 662F
4: Integrated/Intelligent Drive Electronics (IDE)
5: Serial Advanced Technology Architecture (SATA)
6: Serial Attached SCSI (SAS)
9: PCIe SSD
Syntax
Integer
Access
Read-only
Controller State
Name
controllerState
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.5
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Storage Management Group
567
book.book Page 568 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Name
controllerState
Description
Identifies the status of the controller's subsystem (which includes
any devices connected to it). Possible states:
0: Unknown
1: Ready
2: Failed
3: Online
4: Offline
6: Degraded
Syntax
Integer
Access
Read-only
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
568
Storage Management Group
book.book Page 569 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Controller Severity
Name
controllerSeverity
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.6
Description
This entry is obsolete for Storage Management. It was replaced
with RollUpStatus and ComponentStatus for each device.
Syntax
Integer
Access
Read-only
Controller Rebuild Rate in Percent
Name
controllerRebuildRateInPercent
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.7
Description
Identifies the percent of the compute cycles dedicated to
rebuilding failed array disks.
Syntax
Integer
Access
Read-only
Controller Firmware Version
Name
controllerFWVersion
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.8
Description
Identifies the controller's current firmware version.
Syntax
DisplayString
Access
Read-only
Controller Cache Size in Megabytes
Name
controllerCacheSizeInMB
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.9
Description
Identifies the controller's current amount of cache memory in
megabytes. If this size is 0, the cache memory is less than a
megabyte.
Syntax
Integer
Access
Read-only
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Storage Management Group
569
book.book Page 570 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Controller Cache Size in Bytes
Name
controllerCacheSizeInBytes
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.10
Description
Identifies the controller's current amount of cache memory that is
less than a megabyte. This combined with the
controllerCacheSizeInMB is the total amount of memory.
Syntax
Integer
Access
Read-only
Controller Physical Device Count
Name
controllerPhysicalDeviceCount
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.11
Description
Identifies the number of physical devices on the controller
channel including both disks and the controller.
Syntax
Integer
Access
Read-only
Controller Logical Device Count
Name
controllerLogicalDeviceCount
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.12
Description
Identifies the number of virtual disks on the controller.
Syntax
Integer
Access
Read-only
Controller Partner Status
Name
controllerPartnerStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.13
Description
This entry is obsolete for Storage Management.
Syntax
DisplayString
Access
Read-only
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
570
Storage Management Group
book.book Page 571 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Controller Host Port Count
Name
controllerHostPortCount
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.14
Description
This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax
Integer
Access
Read-only
Controller Memory Size in Megabytes
Name
controllerMemorySizeInMB
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.15
Description
Identifies the size of memory in megabytes on the controller. If
this size is 0, it is less than a megabyte.
NOTE: This attribute is only supported on Adaptec controllers.
Syntax
Integer
Access
Read-only
Controller Memory Size in Bytes
Name
controllerMemorySizeInBytes
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.16
Description
Identifies the size of memory on the controller that is less than a
megabyte. This combined with the controllerMemorySizeInMB is
the total size of the memory.
NOTE: This attribute is only supported on Adaptec controllers.
Syntax
Integer
Access
Read-only
Controller Drive Channel Count
Name
controllerDriveChannelCount
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.17
Description
This entry is obsolete. Fibre channel is not supported in Storage
Management.
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Storage Management Group
571
book.book Page 572 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Name
controllerDriveChannelCount
Syntax
Integer
Access
Read-only
Controller Fault Tolerant
Name
controllerFaultTolerant
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.18
Description
This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax
Integer
Access
Read-only
Controller C0 Port 0 World Wide Name
Name
controllerC0Port0WorldWideName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.19
Description
This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax
DisplayString
Access
Read-only
Controller C0 Port 0 Name
Name
controllerC0Port0Name
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.20
Description
This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax
DisplayString
Access
Read-only
Controller C0 Port 0 ID
Name
controllerC0Port0ID
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.21
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
572
Storage Management Group
book.book Page 573 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Name
controllerC0Port0ID
Description
This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax
Integer
Access
Read-only
Controller C0 Target
Name
controllerC0Target
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.22
Description
This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax
Integer
Access
Read-only
Controller C0 Channel
Name
controllerC0Channel
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.23
Description
This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax
Integer
Access
Read-only
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Storage Management Group
573
book.book Page 574 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Controller C0 Operating System Controller
Name
controllerC0OSController
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.24
Description
This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax
DisplayString
Access
Read-only
Controller C0 Battery State
Name
controllerC0BatteryState
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.25
Description
This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax
Integer
Access
Read-only
Controller C1 Port 0 World Wide Name
Name
controllerC1Port0WWN
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.26
Description
This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax
DisplayString
Access
Read-only
Controller C1 Port 0 Name
Name
controllerC1Port0Name
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.27
Description
This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax
DisplayString
Access
Read-only
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
574
Storage Management Group
book.book Page 575 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Controller C1 Port 0 ID
Name
controllerC1Port0ID
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.28
Description
This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax
Integer
Access
Read-only
Controller C1 Target
Name
controllerC1Target
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.29
Description
This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax
Integer
Access
Read-only
Controller C1 Channel
Name
controllerC1Channel
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.30
Description
This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax
Integer
Access
Read-only
Controller C1 Operating System Controller
Name
controllerC1OSController
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.31
Description
This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax
DisplayString
Access
Read-only
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Storage Management Group
575
book.book Page 576 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Controller Battery State C1
Name
controllerC1BatteryState
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.32
Description
This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax
Integer
Access
Read-only
Controller Node World Wide Name
Name
controllerNodeWWN
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.33
Description
This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax
DisplayString
Access
Read-only
Controller C0 Port 1 World Wide Name
Name
controllerC0Port1WWN
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.34
Description
This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax
DisplayString
Access
Read-only
Controller C1 Port 1 World Wide Name
Name
controllerC1Port1WWN
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.35
Description
This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax
DisplayString
Access
Read-only
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
576
Storage Management Group
book.book Page 577 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Controller Battery Charge Count
Name
controllerBatteryChargeCount
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.36
Description
This entry is obsolete. Fibre channel is not supported in Storage
Management.
Syntax
Integer
Access
Read-only
Controller Roll-Up Status
Name
controllerRollUpStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.37
Description
Indicates severity of the controller state. This is the combined
status of the controller and its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax
DellStatus
Access
Read-only
Controller Component Status
Name
controllerComponentStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.38
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Storage Management Group
577
book.book Page 578 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Name
controllerComponentStatus
Description
Indicates the status of the controller itself without the propagation
of any contained component status. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax
DellStatus
Access
Read-only
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
578
Storage Management Group
book.book Page 579 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Controller Nexus ID
Name
controllerNexusID
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.39
Description
Displays the durable unique ID for this controller.
Syntax
DisplayString
Access
Read-only
Controller Alarm State
Name
controllerAlarmState
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.40
Description
Indicates the state or setting for the controller's alarm. Possible
values:
1: Enabled
2: Disabled
3: Not Applicable
Syntax
Integer
Access
Read-only
Controller Driver Version
Name
controllerDriverVersion
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.41
Description
Indicates the currently installed driver version of the controller.
Syntax
DisplayString
Access
Read-only
Controller PCI Slot
Name
controllerPCISlot
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.42
Description
Indicates the PCI slot number or embedded number for
controllers on the motherboard.
Syntax
DisplayString
Access
Read-only
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Storage Management Group
579
book.book Page 580 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Controller Cluster Mode
Name
controllerClusterMode
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.43
Description
Identifies if the controller is in cluster mode.
Possible values:
1: Enabled
2: Disabled
3: Active (enabled and active)
99: Not Applicable
Syntax
Integer
Access
Read-only
Controller Minimum Firmware Version
Name
controllerMinFWVersion
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.44
Description
The minimum firmware version for Storage Management to
support the controller.
Syntax
DisplayString
Access
Read-only
Controller Minimum Driver Version
Name
controllerMinDriverVersion
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.45
Description
The minimum driver version for Storage Management to support
the controller.
Syntax
DisplayString
Access
Read-write
Controller SCSI Initiator ID
Name
controllerSCSIInitiatorID
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.46
Description
Displays the SCSI ID of the initiator.
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
580
Storage Management Group
book.book Page 581 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Name
controllerSCSIInitiatorID
Syntax
Integer
Access
Read-only
Controller Channel Count
Name
controllerChannelCount
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.47
Description
Displays the number of channels on the controller.
Syntax
Integer
Access
Read-only
Controller Reconstruct Rate
Name
controllerReconstructRate
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.48
Description
Displays the rate for reconstruct on the controller.
Syntax
Integer
Access
Read-write
Controller Patrol Read Rate
Name
controllerPatrolReadRate
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.49
Description
Displays the rate for patrol read on the controller.
Syntax
Integer
Access
Read-only
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Storage Management Group
581
book.book Page 582 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Controller BGI Rate
Name
controllerBGIRate
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.50
Description
Displays the rate for background initialization on the controller.
Syntax
Integer
Access
Read-only
Controller Check Consistency Rate
Name
controllerCheckConsistencyRate
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.51
Description
Displays the rate for check consistency on the controller.
Syntax
Integer
Access
Read-only
Controller Patrol Read Mode
Name
controllerPatrolReadMode
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.52
Description
Identifies the patrol read mode.
Possible values:
1: Automatic (enabled)
2: Manual (enabled)
3: Disabled
Syntax
Integer
Access
Read-only
Controller Patrol Read State
Name
controllerPatrolReadState
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.53
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
582
Storage Management Group
book.book Page 583 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Name
controllerPatrolReadState
Description
Displays the state of the patrol read.
Possible values:
1: Stopped - not running
2: Ready - ready to start
4: Active - is running
8: Aborted - has aborted
Syntax
Integer
Access
Read-only
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Storage Management Group
583
book.book Page 584 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Controller Patrol Read Iterations
Name
controllerPatrolReadIterations
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.54
Description
Displays the number of times Patrol Read has been run on this
controller.
Syntax
Integer
Access
Read-only
Controller Storport Driver Version
Name
controllerStorportDriverVersion
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.55
Description
Provides current Windows OS storport driver version.
NOTE: Not applicable for Linux.
Syntax
Octet String
Access
Read-only
Controller Minimum Required Storport Version
Name
controllerMinimumRequiredStorportVersion
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.56
Description
Provides minimum required storport driver version for Windows
OS only.
NOTE: Not applicable for Linux.
Syntax
Octet String
Access
Read-only
Controller Encryption Capable
Name
controllerEncryptionCapable
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.57
Description
Indicates the encryption capability of the controller.
Possiable Values:
1 - Capable
99 - Not Applicable
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
584
Storage Management Group
book.book Page 585 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Name
controllerEncryptionCapable
Syntax
Integer
Access
Read-only
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Storage Management Group
585
book.book Page 586 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Controller Encryption Key Present
Name
controllerEncryptionKeyPresent
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.58
Description
Indicates presence of encryption key for the controller.
Possiable Values:
1 - Yes
0 - No
99 - Not Applicable
Syntax
Integer
Access
Read-only
Controller Persistent Hot Spare
Name
controllerPersistentHotSpare
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.59
Description
Indicates the Persistent Hot Spare capability of the controller.
Possiable Values:
1 - Enabled
0 - Disabled
99 - Undetermined / Not applicable
Syntax
Integer
Access
Read-only
Controller Spin Down Unconfigured Drives
Name
controllerSpinDownUnconfiguredDrives
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.60
Description
Indicates controller capability to move unconfigured drives to
power save mode.
Possiable Values:
1 - Enabled
0 - Disabled
99 - Undetermined / Not applicable
Syntax
Integer
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
586
Storage Management Group
book.book Page 587 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Name
controllerSpinDownUnconfiguredDrives
Access
Read-only
Controller Spin Down Hot Spare Drives
Name
controllerSpinDownHotSpareDrives
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.61
Description
Indicates controller capability to move hot spare drives to power
save mode.
Possiable Values:
1 - Enabled
0 - Disabled
99 - Undetermined / Not applicable
Syntax
Integer
Access
Read-only
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
Storage Management Group
587
book.book Page 588 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Controller Spin Down Time Interval
Name
controllerSpinDownTimeInterval
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.62
Description
Shows the duration in minutes after which, the unconfigured or
hot spare drives is spun down to power save mode.
Possiable Values: 30 to 1440
NOTE: A value of 9999 indicates that the feature is not available.
Syntax
Integer
Access
Read-write
Controller Encryption Mode
Name
controllerEncryptionMode
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.63
Description
Indicates the current encryption mode of the controller.
Possiable Values:
0 - No Encryption
1 - Local Key Management (LKM)
2 - Dell Key Management (DKM)
99 - Not Applicable
Syntax
Integer
Access
Read-only
Controller CacheCade
Name
controllerCacheCade
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.64
Description
Indicates if the controller is CacheCade capable or not.
Possiable Values:
1 - Capable
0 - Not Capable
99 - Undetermined
Syntax
Integer
Access
Read-only
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 3 / 6 / 1 3 - F O R P R O O F O N LY
588
Storage Management Group
book.book Page 589 Wednesday, March 6, 2013 12:37 AM
FILE LOCATION: C:\Projects -Solutions\SNMP\Mainak\SNMPc24.fm
Controller Spin Down Configured Drives
Name
controllerSpinDownConfiguredDrives
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.65
Description
Indicates the controller capability to spin down configured
physical disks.
Possiable Values:
0 - Disabled
1 - Enabled
99 - Undetermined
Syntax
Integer
Access
Read-only
Controller Automatic Power Saving
Name
controllerAutomaticPowerSaving
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.66
Description
In