Dell OpenManage Server Administrator Version 5.2 SNMP Reference Guide

Dell™ OpenManage™ Server
Administrator Version 5.2
SNMP Reference Guide
w w w. d e l l . c o m | s u p p o r t . d e l l . c o m
Notes and Notices
NOTE: A NOTE indicates important information that helps you make better use of your computer.
NOTICE: A NOTICE indicates either potential damage to hardware or loss of data and tells you how to avoid the problem.
____________________
Information in this document is subject to change without notice.
© 2003–2007 Dell Inc. All rights reserved.
Reproduction in any manner whatsoever without the written permission of Dell Inc. is strictly forbidden.
Trademarks used in this text: Dell, the DELL logo, PowerEdge, PowerVault, and OpenManage are trademarks of Dell Inc.; Microsoft, Windows,
and Windows NT are registered trademarks of Microsoft Corporation; Intel, Itanium, Pentium, and Celeron are registered trademarks, and MMX,
Xeon, Core and Intel386 are trademarks of Intel Corporation; UNIX is a registered trademark of The Open Group in the United States and in
other countries; VESA is a registered trademark of the Video Electronics Standards Association; AMD, AMD Athlon, AMD Opteron,
AMD Sempron, AMD Turion, and AMD Duron are trademarks of Advanced Micro Devices, Inc.
Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products.
Dell Inc. disclaims any proprietary interest in trademarks and trade names other than its own.
April 2007
Contents
1
Introduction
Audience
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13
What’s New in this Release
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Introduction to the SNMP Reference Guide .
. . . . . . . . . .
. . . . . . . . . . . . . . . . . .
14
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
General Content . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Server Administrator Instrumentation MIB. . . . . . . . . . . . . .
Server Administrator Remote Access MIB . . . . . . . . . . . . . .
Server Administrator Baseboard Management Controller, ASF MIB
Server Administrator Field Replaceable Unit MIB . . . . . . . . . .
Server Administrator Storage Management MIB . . . . . . . . . .
Server Administrator Change Management MIB . . . . . . . . . .
How This Guide Defines Technical Terms . . . . . . . . . . . . . .
SNMP Basic Terminology. . . . . . . . . . . . . . . . . . . . . . .
Frequently Used Terms in Variable Names . . . . . . . . . . . . . .
Tables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reference Guide Content Tables . . . . . . . . . . . . . . . . . . .
Section Organization . . . . . . . . . . . . . . . . . . . . . . . . .
Other Documents You May Need . . . . . . . . . . . . . . . . . . .
. . .
14
15
16
17
17
17
18
18
19
21
22
24
24
25
. . . . . . . . . .
25
. . . . . . . . . . . . . . . . . . . . . . . . . . .
26
27
28
28
Introduction to the Server Administrator SNMP Subagent .
SNMP MIB OIDs . . .
SNMP Security . . . .
Management Actions .
SNMP Traps . . . . . .
13
13
13
13
14
14
What's New in the Instrumentation MIB . . . . . . . .
What's New in the Remote Access MIB . . . . . . . .
What's New in the Field Replaceable Unit MIB . . . .
What's New in the Storage Management Group MIB .
What's New in the Change Management MIB . . . . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Contents
3
2
Instrumentation MIB Version Group
. . . . . . . . . . . . . . . .
29
MIB Major Version Number
. . . . . . . . . . . . . . . . . . . . . . . . . . .
29
MIB Minor Version Number
. . . . . . . . . . . . . . . . . . . . . . . . . . .
29
MIB Maintenance Version Number
3
. . . . . . . . . . . . . . . . . . . . . . .
Systems Management Software Group
Systems Management Software .
. . . . . . . . . . . . . .
31
. . . . . . . . . . . . . . . . . . . . . . . .
31
. . . . . . .
32
32
32
32
33
33
33
33
34
34
34
34
35
. . . . . . . . . . . . . . .
35
. . . . . . . . . . . . . . . . . . . . . . . . . . .
37
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
37
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
37
Systems Management Software Name . . . . . . . . . . .
Systems Management Software Version Number Name . .
Systems Management Software Build Number . . . . . . .
Systems Management Software Description Name . . . . .
Systems Management Software Supported Protocol . . . .
Systems Management Software Preferred Protocol . . . . .
Systems Management Software Update Level Name . . . .
Systems Management Software URL Name . . . . . . . . .
Systems Management Software Language Name . . . . . .
Systems Management Software Global Version Name . . .
Systems Management Software Feature Flags . . . . . . .
Systems Management Software SNMP Agent Feature Flags
Systems Management Software Manufacturer Name . . . .
Systems Management Software Variable Values .
4
System State Group .
System State Group Table
System State Table
5
Chassis Information Group .
Chassis Information Table
UUID Table . . . . . . . .
POST Log Table . . . . . .
Event Log Table . . . . . .
System BIOS Table . . . .
Contents
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
55
. . . . . . . . . . . . . . . . . . . . . . .
55
. . . . . . . . . . . . . . . . . . . . . . . . .
55
67
69
71
73
Chassis Information Group Tables .
4
30
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
Firmware Table .
Intrusion Table .
Baseboard Table
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Chassis Information Group Variable Values .
6
Operating System Group.
Operating System Group Table .
101
. . . . . . . . . . . . . . . . . . . . . . . .
101
. . . . . . . . . . . . . . . . . . . .
101
103
. . . . . . . . . . . . . . . . . . . . . . .
107
. . . . . . . . . . . . . . . . . . . . . . . .
107
System Resource Group .
System Resource Group Tables
. . . . . . . . . . . . . . . . . . . .
. . . . . . . . .
107
109
112
115
118
121
. . . . . . . . . . . . . . . . . . .
124
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
127
System Resource Map Table . . . . . . . . . . . . . .
System Resource Owner Table . . . . . . . . . . . . .
System Resource Input/Output (I/O) Port Table . . . .
System Resource Memory Table . . . . . . . . . . . .
System Resource Interrupt Table . . . . . . . . . . . .
System Resource Direct Memory Access (DMA) Table
System Resource Group Variable Values
8
Power Group .
89
. . . . . . . . . . . . . . . . . . . . . . .
Operating System Table . . . . . .
Operating System Memory Table .
7
. . . . . . . . . . . . . . . . . .
79
82
85
Power Group Tables
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Unit Table . . . .
Power Supply Table . . .
Voltage Probe Table. . .
Amperage Probe Table .
AC Power Switch Table .
AC Power Cord Table . .
Battery Table . . . . . .
Power Group Variable Values
127
. . . . . . . . . . . . . . . . . . . . . . . . .
127
130
133
138
142
145
147
. . . . . . . . . . . . . . . . . . . . . . . . .
149
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
Contents
5
9
Thermal Group
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Thermal Group Tables
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
157
Cooling Unit Table . . . . .
Cooling Device Table . . .
Temperature Probe Table .
. . . . . . . . . . . . . . . . . . . . . . . .
157
160
165
Thermal Group Variable Values
. . . . . . . . . . . . . . . . . . . . . . . .
169
10 User Security Group
. . . . . . . . . . . . . . . . . . . . . . . . . .
173
User Security Group Table .
. . . . . . . . . . . . . . . . . . . . . . . . . .
173
. . . . . . . . . . . . . . . . . . . . . . . . . . .
173
User Security Table .
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .
11 Remote Flash BIOS Group
. . . . . . . . . . . . . . . . . . . . . .
175
. . . . . . . . . . . . . . . . . . . . . . .
175
. . . . . . . . . . . . . . . . . . . . . . . .
175
Remote Flash BIOS Group Table .
Remote Flash BIOS Table .
. . . . . . . . . . . . . . . . . . . . .
178
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
181
Remote Flash BIOS Variable Values .
12 Port Group
Port Group Tables
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Port Group Variable Values
Contents
181
. . . . . . . . . .
181
184
187
190
193
196
198
202
206
. . . . . . . . . . . . . . . . . . . . . . . . . .
209
Pointing Port Table . . . . . . . . . . . . . . . . . .
Keyboard Port Table . . . . . . . . . . . . . . . . .
Processor Port Table . . . . . . . . . . . . . . . . .
Memory Device Port Table . . . . . . . . . . . . . .
Monitor Port Table . . . . . . . . . . . . . . . . . .
Small Computer System Interface (SCSI) Port Table .
Parallel Port Table . . . . . . . . . . . . . . . . . .
Serial Port Table . . . . . . . . . . . . . . . . . . .
Universal Serial Bus (USB) Port Table . . . . . . . .
6
157
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . .
13 Device Group
Device Tables
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
213
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
213
. . . . . . . . . . . . . . . .
213
216
218
226
228
234
241
244
247
250
253
. . . . . . . . . . . . . . . . . . . . . . . .
261
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
277
Pointing Device Table . . . . . . . . . . .
Keyboard Device Table . . . . . . . . . .
Processor Device Table. . . . . . . . . .
Processor Device Status Table . . . . . .
Cache Device Table . . . . . . . . . . . .
Memory Device Table . . . . . . . . . . .
Memory Device Mapped Address Table .
Generic Device Table . . . . . . . . . . .
PCI Device Table . . . . . . . . . . . . .
PCI Device Configuration Space Table . .
Network Device Table . . . . . . . . . .
Device Group Variable Values .
14 Slot Group
System Slot Group Table .
System Slot Table .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . .
277
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
277
System Slot Variable Values .
15 Memory Group
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
281
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
289
Physical Memory Tables .
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Memory Group Variable Values
289
. . . . . . . . . . . . . . . . .
289
294
297
299
301
303
. . . . . . . . . . . . . . . . . . . . . . . .
306
Physical Memory Array Table. . . . . .
Physical Memory Array Mapped Table .
Physical Memory Configuration Table .
Physical Memory Logging Table . . . .
Redundant Memory Unit Table . . . . .
Physical Memory Card Table . . . . . .
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . .
Contents
7
16 BIOS Setup Control Group
BIOS Group Tables .
. . . . . . . . . . . . . . . . . . . . . .
311
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
311
. . . . . . . . . . . . . . . . . . . . .
311
321
323
325
327
329
331
333
. . . . . . . . . . . . . . . . . . . . . . . . .
335
BIOS Setup Control Table . . . .
SCSI Control Table . . . . . . .
Parallel Port Control Table . . .
Serial Port Control Table . . . .
USB Control Table . . . . . . . .
IDE Control Table . . . . . . . .
Diskette Control Table. . . . . .
Network Interface Control Table
BIOS Group Variable Values .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
17 Local Response Agent Group
LRA Group Tables
. . . . . . . . . . . . . . . . . . . .
345
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
345
LRA Global Settings . . . .
LRA Global Settings Table
LRA Action Table . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . .
Local Response Agent Variable Values
. . . . . . . . . . . . . . . . . . . .
350
. . . . . . . . . . . . . . . . . . . . . .
353
. . . . . . . . . . . . . . . . . . . . . . .
353
18 Cost of Ownership Group .
Cost of Ownership Group Tables
. . . . . . . . . . . . . . . . . . . . .
353
364
366
368
370
373
374
376
378
380
383
. . . . . . . . . . . . . . . . . . . . . .
385
Cost of Ownership Table . . . .
COO Service Contract Table . .
COO Cost Event Log Table . . .
COO Warranty Table . . . . . .
COO Lease Information Table . .
COO Schedule Number Table . .
COO Options Table . . . . . . .
COO Maintenance Table . . . .
COO Repair Table . . . . . . . .
COO Support Information Table .
COO Trouble Ticket Table . . . .
Cost of Ownership Variable Values
8
Contents
345
345
348
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
19 Remote Access Group .
DRAC 4 and DRAC 5
. . . . . . . . . . . . . . . . . . . . . . . .
387
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
387
. . . . . . . . . . . . . . . . . . . . . . . . . .
387
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
393
Remote Access Table .
DRAC III.
. . . . . . . . . . . . . . . .
393
402
410
414
418
421
. . . . . . . . . . . . . . . . . . . . . . .
424
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
437
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
437
Remote Access Table . . . . . . . . . . .
Remote User Administration Table . . . .
Remote SNMP Trap Table . . . . . . . .
Remote Dial-Up Table . . . . . . . . . . .
Remote User Dial-In Configuration Table .
Remote Dial-Out Table . . . . . . . . . .
Remote Access Variable Values .
20 Cluster Group
Cluster Group .
Cluster Table
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cluster Group Variable Values .
. . . . . . . . . . . . . . . . . . . . . . . .
21 Baseboard Management Controller Group .
Baseboard Management Controller Group Tables
441
. . . . . . . . . . . . . .
441
. . . . . . .
441
444
447
. . . . . . . . .
451
. . . . . . . . . . . . . . . . . . . .
455
Baseboard Management Controller Group Variable Values
Field Replaceable Unit Group Tables
. . . . . . .
. . . . . . .
. . . . . . . . . . . . . . . . . . . . .
455
. . . . . . . . . . . . . . . . . . . . . . .
455
. . . . . . . . . . . . . . . . . . . . . . . . . .
459
Field Replaceable Unit Table
FRU Group Variable Values
440
. . . . . . . . . .
Baseboard Management Controller Table . . . . . . . . .
Baseboard Management Controller Serial Interface Table
Baseboard Management Controller LAN Interface Table .
22 Field Replaceable Unit Group
437
Contents
9
23 Storage Management Group
Storage Management Group .
. . . . . . . . . . . . . . . . . . . .
461
. . . . . . . . . . . . . . . . . . . . . . . . .
461
. . . . . . . . . . . . . . . . . . .
463
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
464
Storage Management Information Group
Global Data Group
Physical Devices Group
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Logical Devices Group .
. . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
544
Storage Management Event Group
. . . . . . . . . . .
. . . . . . . . . . .
. . . . . . . . . . .
. . . . . . . . . . .
. . . . . . . . . . .
. . . . . . . . . . .
. . . . . . . . . . .
. . . . . . . . . . .
. . . . . . . . . . .
. . . . . . . . . . .
. . . . . . . . . . .
. . . . . . . . . . .
. . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . .
554
. . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . .
557
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
557
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
558
Inventory Group
. . . . . . . . . . . . . . . . . . . . . . . . . . .
558
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
560
Device Group Table .
Application Group
Application Group Table
Contents
. . . . . . . . . . .
. . . . . . . . . . . . . . . . . .
24 Change Management Group .
10
. . . . . . . . . . .
545
552
Virtual Disk Table . . . . . . . . . . .
Array Disk Logical Connection Table .
Device Group .
469
470
485
489
498
508
510
513
518
520
524
525
530
532
536
538
542
Controller Table . . . . . . . . . . . . . . . . . . .
Channel Table . . . . . . . . . . . . . . . . . . . .
Enclosure Table . . . . . . . . . . . . . . . . . . .
Array Disk Table. . . . . . . . . . . . . . . . . . .
Array Disk Enclosure Connection Table . . . . . .
Array Disk Channel Connection Table . . . . . . .
Fan Table . . . . . . . . . . . . . . . . . . . . . .
Fan Connection Table . . . . . . . . . . . . . . . .
Power Supply Table . . . . . . . . . . . . . . . . .
Power Supply Connection Table . . . . . . . . . .
Temperature Probe Table . . . . . . . . . . . . . .
Temperature Probe Connection Table . . . . . . .
Enclosure Management Module Table . . . . . . .
Enclosure Management Module Connection Table
Battery Table . . . . . . . . . . . . . . . . . . . .
Battery Connection Table . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
560
Operating System Group .
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Inventory Collector Product Information
25 Traps
562
. . . . . . . . . . . . . . . . . . .
564
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
567
Trap Variables
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
System. . . . . .
Table Index OID .
Message . . . .
Current Status . .
Previous Status .
Data . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
568
568
568
568
568
569
. . . . . . . . . . . . . . . . . . . . .
569
. . . . . . . . . . . . . . . . . . . . . . . . .
572
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
572
Understanding the Trap Description .
Understanding Trap Severity.
Instrumentation Traps
567
. . . . . . . . . . . . . . . . . . . . .
573
574
576
577
579
581
581
583
584
585
586
587
588
589
590
RAC Traps
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
591
BMC Traps
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
594
Miscellaneous Traps . . . . . .
Temperature Probe Traps . . . .
Cooling Device Traps . . . . . .
Voltage Probe Traps . . . . . .
Amperage Probe Traps . . . . .
Chassis Intrusion Traps . . . . .
Redundancy Unit Traps . . . . .
Power Supply Traps . . . . . . .
Memory Device Traps. . . . . .
Fan Enclosure Traps . . . . . .
AC Power Cord Traps . . . . . .
Hardware Log Traps . . . . . .
Processor Device Status Traps .
Pluggable Device Traps . . . . .
Battery Traps . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . .
Contents
11
26 Storage Management Alert Reference
. . . . . . . . . . . . .
597
. . . . . . . . . . . . . . . . . . . . . . . . .
597
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
597
Alert Monitoring and Logging
Viewing Alerts
Alert Severity Levels .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . .
598
. . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . .
598
599
599
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
599
SNMP Support for Storage Management Alerts
SNMP Trap Forwarding .
SNMP Trap Definitions .
SNMP Trap Variables . .
Viewing SNMP Traps
. . . . . . . . . . . . . . . . . . . . . . . . .
Alert Descriptions and Corrective Actions
. . . . . . . . . . . . . . . . . .
600
A Standard Data Type Definitions .
. . . . . . . . . . . . . . . . . .
601
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
601
Common Data Types
Variables with Data Types of State Capabilities and
State Capabilities Unique . . . . . . . . . . . . . .
. . . . . . . . . . . . .
602
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
603
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
605
Dell Status Data Types .
Dell Date
Full Dates
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B SNMP Sample Output
Index .
Contents
605
. . . . . . . . . . . . . . . . . . . . . . . . .
607
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
611
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
633
Glossary
12
598
Introduction
This introduction is divided into two sections. The first section, "Introduction to the SNMP
Reference Guide," explains the SNMP Reference Guide design. All essential Simple Network
Management Protocol (SNMP) terms are defined in this section. Some of the vocabulary may seem
complex and unfamiliar to system administrators who are using SNMP for the first time.
SNMP experts can skim this section, and beginners can read the section more carefully.
The second section, "Introduction to the Server Administrator SNMP Subagent," is a more technical
introduction to the management information base (MIB) that underlies Server Administrator services.
Audience
This guide is intended for system administrators, network administrators, and anyone who wants to
write SNMP MIB applications to monitor systems.
What’s New in this Release
This section lists changes to the Server Administrator MIBs in this release of Server Administrator.
What's New in the Instrumentation MIB
•
Updated the Processor Device Family with the new deviceFamilyIsIntelCore2(190)
value.
•
Increased the size of the following MIB string attributes:
–
systemManagementSoftwareURLName
–
operatingSystemOperatingSystemName
–
operatingSystemOperatingSystemVersionName
What's New in the Remote Access MIB
No changes.
What's New in the Field Replaceable Unit MIB
No changes.
Introduction
13
What's New in the Storage Management Group MIB
•
Added the new enclosureSASAddress attribute to the Enclosure Table.
•
Changed the syntax of the following objects from octet strings to display strings:
–
controllerPCISlot
–
enclosureSCSIRate
–
arrayDiskSASAddress
What's New in the Change Management MIB
No changes.
Introduction to the SNMP Reference Guide
This reference guide provides a formatted version of the Server Administrator Instrumentation MIB
(filename 10892.mib), the Server Administrator Remote Access MIB (filename dcs3rmt.mib), the Server
Administrator Field Replaceable Unit MIB (filename dcs3fru.mib), the Server Administrator Storage
Management MIB (filename dcstorag.mib), and the Server Administrator Change Management MIB
(filename dellcm.mib) that are released with the current version of Dell™ OpenManage™ Server
Administrator.
Sections in this guide follow MIB groups and provide explanations and definitions for the terms used to
define MIB objects. Content in this reference guide is organized as documented in the following subsections.
General Content
Table 1-1 describes the sections that provide general information about the MIBs documented in this guide.
Table 1-1.
Section
Topics
1
Introduction to SNMP basics and to the MIBs that support Server Administrator services NA
25
Traps — describes in-band traps defined in the Server Administrator Instrumentation
5000
MIB and out-of-band traps sent by the Remote Access Controller (RAC) and Baseboard
Management Controller (BMC).
MIB Group
Number
Appendix A Standard Data Type Definitions — defines standard data types used in this
reference guide.
NA
Appendix B SNMP Sample Output — provides a sample SNMP output.
NA
Glossary
14
General Content Sections in This Guide
Defines acronyms, abbreviations, and technical terms used in this reference guide.
Introduction
NA
Server Administrator Instrumentation MIB
The Server Administrator Instrumentation MIB (filename 10892.mib) provides instrumentation data that
allows you to monitor the health of a system with SNMP management applications. It provides:
•
Information about the status of temperatures, power supplies, voltages, currents, fans, and memory at
key points in the system
•
Rapid access to detailed fault and performance information gathered by industry standard systems
management agents
•
Version information for Basic Input/Output System (BIOS), firmware, and operating system
•
A detailed account of every cost of ownership (COO) detail about your system
In addition, traps are sent to report a change in status of the health of critical components.
The Server Administrator Instrumentation MIB structures its MIB objects into groups of scalar objects
or MIB tables that provide related information. Table 1-2 describes each Server Administrator
Instrumentation MIB group and lists the MIB group number assigned to the MIB group.
The Server Administrator Instrumentation MIB groups are identified by the SNMP OID
1.3.6.1.4.1.674.10892.1.<MIB group number>, where <MIB group number> is the MIB group number
assigned to the MIB group. See the relevant section for more information about the MIB objects defined
in a MIB group.
Table 1-2.
Server Administrator Instrumentation MIB Sections in This Guide
Section
Topics
2
Instrumentation MIB Version Group — defines version numbers of the Instrumentation MIB 1
3
Systems Management Software Group — defines information about the systems
management software and the supported systems management standards
100
4
System State Group — defines status, state, and redundancy for a system and its components
200
5
Chassis Information Group — defines chassis types, events, and indicators
300
6
Operating System Group — defines variables for name, version, service pack, and other
information about a system’s operating system
400
7
System Resource Group — defines variables for input/output ports, memory, interrupts, and 500
direct memory access
8
Power Group — defines variables for power units, power supplies, and their current and
voltage probes
600
9
Thermal Group — defines variables for temperature probes and cooling devices
700
10
User Security Group — defines variables for creating and modifying user accounts
800
11
Remote Flash BIOS Group — defines variables for updating the system’s BIOS remotely
900
12
Port Group — defines variables for major port types such as keyboard, monitor, small computer 1000
system interface (SCSI), Universal Serial Bus (USB), and parallel and serial ports
MIB Group
Numbers
Introduction
15
Table 1-2.
Server Administrator Instrumentation MIB Sections in This Guide (continued)
Section
Topics
MIB Group
Numbers
13
Device Group — defines variables for pointing, keyboard, processor, cache, memory,
and personal computer interface devices
1100
14
Slot Group — defines variables for the system’s slots
1200
15
Memory Group — defines variables for the system’s physical memory
1300
16
BIOS Setup Control Group — defines variables for BIOS functions such as boot sequence, 1400
speakers, Wake on the local area network (LAN), diskettes, ports, and
network interface controllers (NIC)
17
Local Response Agent Group — defines variables for global settings and actions. These variables 1500
allow users to predetermine how the system responds to a particular type of event
18
Cost of Ownership Group — defines variables for tracking data on the system’s service
contract, lease, repair records, trouble tickets, and so on
1600
20
Cluster Group — defines variables for systems that operate as a cluster
1800
21
Baseboard Management Controller Group — provides information about the Baseboard
Management Controller (BMC) that may be present in your system. In addition to
providing general information about the BMC, this group provides information about the
serial and local area network (LAN) interfaces of the BMC
1900
25
Traps — defines the types of alerts that can be sent to report the status of critical components 5000
Server Administrator Remote Access MIB
The Server Administrator Remote Access MIB (filename dcs3rmt.mib) provides in-band information
about remote access hardware that may be present in your system.
The Server Administrator Remote Access MIB structures its MIB objects into groups of scalar objects or
MIB tables that provide related information. Table 1-3 describes each Server Administrator Remote
Access MIB group and lists the MIB group number assigned to the MIB group. The Server Administrator
Remote Access MIB groups are identified by the SNMP OID 1.3.6.1.4.1.674.10892.1.<MIB group number>
where <MIB group number> is the MIB group number assigned to the MIB group. See the relevant
section for more information about the MIB objects defined in a MIB group.
16
Table 1-3.
Server Administrator Remote Access MIB Sections in This Guide
Section
Topic
MIB Group
Numbers
19
Remote Access Group — provides information about remote access hardware that may be
present in your system and defines variables for administrative users, SNMP trap
destinations, modem configuration for dial-up networking, dial-in configuration, and
dial-out destinations
1700
Introduction
Server Administrator Baseboard Management Controller, ASF MIB
The Server Administrator BMC MIB (filename DcAsfSrv.mib) provides information about the traps sent
by BMC. The Server Administrator BMC MIB structures its MIB objects that provide related information.
The BMC MIB groups are identified by the SNMP OID 1.3.6.1.4.1.3183.1.1.<MIB group number>
The BMC MIB is adheres to ASF 2.0 standard and hence the enterprise ID is wired for
management (3183).
Server Administrator Field Replaceable Unit MIB
The Server Administrator Field Replaceable Unit MIB (filename dcs3fru.mib) provides information
about field replaceable unit (FRU) hardware that may be present in your system.
The Server Administrator Field Replaceable Unit MIB structures its MIB objects into groups of scalar
objects or MIB tables that provide related information. Table 1-4 describes each Server Administrator
Field Replaceable Unit MIB group and lists the MIB group number assigned to the MIB group.
The Server Administrator Field Replaceable Unit MIB groups are identified by the SNMP OID
1.3.6.1.4.1.674.10892.1.<MIB group number> where <MIB group number> is the MIB group number
assigned to the MIB group. See the relevant section for more information about the MIB objects defined
in a MIB group.
Table 1-4. Server Administrator Field Replaceable Unit MIB Sections in This Guide
Section
Topic
MIB Group
Numbers
22
Field Replaceable Unit Group — provides information about field replaceable units that
may be present in your system
2000
Server Administrator Storage Management MIB
The Server Administrator Storage Management MIB (filename dcstorag.mib) provides storage management
data that allows you to monitor the health of storage resources with SNMP management applications.
Table 1-5 describes each Server Administrator Storage Management MIB group and lists the MIB group
number assigned to the MIB group. The Server Administrator Storage Management MIB groups are
identified by the SNMP OID 1.3.6.1.4.1.674.<MIB group number> where <MIB group number> is the
MIB group number assigned to the MIB group. See the relevant section for more information about the
MIB objects defined in a MIB group.
Introduction
17
Table 1-5. Server Administrator Storage Management MIB Sections in This Guide
Section
Topics
MIB Group
Numbers
23
Storage Management Group — consists of definitions for the following MIB groups:
• Storage Management Group
• Storage Management Information Group
• Global Data Group
• Physical Devices Group
• Logical Devices Group
• Storage Management Event Group
10893
26
Storage Management Alert Reference — lets you monitor the health of storage
resources such as controllers, connectors, array disks, and virtual disks
NA
Server Administrator Change Management MIB
The Server Administrator Change Management MIB (filename dellcm.mib) provides management data
that allows you to monitor the inventory of devices and applications with SNMP management applications.
Table 1-6 describes each Server Administrator Change Management MIB group and lists the MIB group
number assigned to the MIB group. The Server Administrator Change Management MIB groups are
identified by the SNMP OID 1.3.6.1.4.1.674.<MIB group number> where <MIB group number> is the
MIB group number assigned to the MIB group. See the relevant section for more information about the
MIB objects defined in a MIB group.
Table 1-6. Server Administrator Change Management MIB Sections in This Guide
Section
Topics
MIB Group
Number
24
Change Management Group - describes the inventory data provided by the
Change Management MIB that allows users to monitor devices and software
present on a particular managed computer chassis
10899
How This Guide Defines Technical Terms
The following table provides information about where to find definitions for technical terms in this
reference guide.
18
Introduction
Table 1-7. Where to Find Definitions for Technical Terms
Type of Definition
See
Basic SNMP vocabulary.
Introduction
MIB-group-specific variable values. MIB-group-specific MIB
variables contain links to the tables that define these values in the
last section of the section in which these variables are used.
Sections 3, 5, 7, 8, 9, and 11 through 18.
Systems management terms, acronyms, and commonly managed
components referred to in this reference guide.
Glossary
Server Administrator-standard data types that specify variable
values in this reference guide.
Appendix A, "Standard Data Type
Definitions."
SNMP Basic Terminology
It is important to have a good understanding of the key technical terms used in this guide. This guide
provides definitions for all essential terms used in describing the Server Administrator MIBs.
The Glossary contains definitions for all essential terms and acronyms.
SNMP Master Agent
Typically, the SNMP agent on a managed system consists of one SNMP master agent and zero or more SNMP
extension agents. This SNMP agent extendable structure facilitates the addition of new MIB modules
without having to rebuild the entire SNMP agent and is invisible to SNMP management applications.
The SNMP master agent is responsible for receiving SNMP request protocol messages from SNMP management
applications and sending SNMP response protocol messages. As part of processing SNMP request
protocol messages, the SNMP master agent typically communicates with one or more SNMP extension
agents. This communication does not involve standard SNMP protocol messages. The SNMP master
agent uses an extension protocol that shields the SNMP extension agent from the standard SNMP
protocol messages. The extension protocol also provides a way for SNMP extension agents to send SNMP
event notifications (called traps in SNMPv1). The SNMP master agent is also responsible for sending
SNMP event notification protocol messages to SNMP management applications.
On supported operating systems, the SNMP master agent is provided with the operating system.
For example, on supported Microsoft® Windows® operating systems, the Windows SNMP service is the
SNMP master agent. For information on the versions of the SNMP protocol supported by the SNMP
master agent, see the operating system documentation.
SNMP Extension Agent
The SNMP extension agent is responsible for registering the MIB objects that it supports with the
SNMP master agent and then processing requests from the SNMP master agent for those MIB objects.
The SNMP extension agent also initiates event notifications to the SNMP master agent. The SNMP
extension agent does not receive or send standard SNMP protocol messages. The SNMP extension agent
communicates with the SNMP master agent using an extension protocol defined by the SNMP master agent.
The Server Administrator SNMP subagent is an SNMP extension agent.
Introduction
19
Managed Object
A managed object is any item in a computer system that can be singled out for discovery, monitoring,
or user intervention and correction.
NOTE: Not all managed objects described in this guide are supported by all systems.
MIB
A MIB acts as a structured road map for managed objects. As an Application Programming Interface
(API), a MIB allows systems management tools to retrieve data maintained by an agent. The server
administrator MIB is divided into several major groups of managed objects.
Variable
A variable is a component of a managed object. A temperature probe, for example, has a variable to
describe its capabilities, its health or status, and certain indexes that you can use to locate specific
temperature probes. One index for the probe would be the probe’s chassis number. Some systems may
have multiple chassis—one chassis for the central processing unit and another chassis for storage.
A chassis within a system can also have more than one temperature probe. Variables for a temperature
probe include its capabilities, status, chassis index, and index.
One-Based Index
When an index is one-based, counting starts at 1. One-based indexing counts the first instance as 1,
the second index as 2, and so on.
Zero-Based Index
When an index is zero-based, counting starts at 0. Zero-based indexing counts the first instance as 0,
the second index as 1, and so on.
Fields
Managed object variables contain fields. In this reference guide, managed object variables have the
following fields defined:
Name is the exact string by which the variable is known in the MIB. MIB variables are named according
to the following conventions:
20
•
Variable names start with a lowercase letter.
•
Spaces are not allowed between words in the variable name.
•
Acronyms are in uppercase letters, except when an acronym is the first word in the variable name.
•
With the exception of the first letter of the variable name and acronyms, all other words in the variable
name start with capital letters.
Introduction
The following variable names illustrate these conventions:
temperatureProbeLowerCriticalThreshold
coolingUnitIndex
pCIDeviceSpeed
Object Identifier (OID) is the unique number assigned to an object defined in a MIB. An OID is
written as a sequence of subidentifiers in decimal notation. Each OID in this reference guide has a prefix
that identifies the managed objects as belonging to Dell™: 1.3.6.1.4.1.674. The additional numbers
identify the MIB group and subgroup as well as the table entry number of any variables.
For example, the OID for the temperature probe managed object table is 700.20 and the variable for the
location of the temperature probe (temperatureProbeLocationName) has an OID of 700.20.1.8. The full
OIDs for these items are 1.3.6.1.4.1.674.10892.1.700.20 for the temperatureProbeTable and
1.3.6.1.4.1.674.10892.1.700.20.1.8 for the temperatureProbeLocation. For more information about the
structure of OIDs, see "SNMP MIB OIDs."
Description is a brief explanation of what a particular managed object does.
Syntax defines the data type in which the values of the variable must be expressed. Most variables in this
reference guide use standard data types such as string or boolean. All data types that are unique to server
administrator variables are defined at the end of the section in which they occur. Standard data types are
defined in "Standard Data Type Definitions."
Access specifies whether persons with administrative privileges can read but not modify the value of a
variable (read only) or can both read and modify the value of a variable (read-write).
Frequently Used Terms in Variable Names
The following terms are frequently used in the name of a MIB variable:
Capability refers to the actions an object can perform, or to actions that can be taken by the object.
Hot-pluggable is an example of a capability. If a card is hot-pluggable, it can be replaced while a system is
running. Capability settings refer to the capabilities of the object that the user can select from and
activate if desired. Capability settings allow users of the server administrator to predetermine how an
object will behave under specific conditions.
Settings are the conditions of a manageable object that determine what happens when a certain value is
detected in a component. For example, a user can set the upper critical threshold of a temperature probe
to 75 degrees Celsius. If the probe reaches that temperature, the setting causes an alert to be sent to the
management console. Some settings, when reached, can trigger a system shutdown or other response to
prevent damage to the system.
State refers to the condition of an object that has more than one condition. For example, an object may
be in a "not ready" or in an "enabled" state.
Status refers to the health of an object or how the object is functioning. For example, the status of a
temperature probe that is measuring acceptable temperatures would be reported as normal. When the
probe begins reading temperatures that exceed limits set by the user, it reports a critical status.
Introduction
21
Tables
This reference guide contains two types of tables: tables that are used to organize and define variable
values and tables that define MIB objects. Readers must understand the differences between these
two types of tables.
SNMP Tables
Most of the MIB objects defined in this reference guide are organized into SNMP tables. SNMP tables
organize data into two-dimensional structural arrays. In SNMP, objects that have a relationship to other
objects are called columnar objects. Columnar objects are the type of object used to form lists and tables.
When a MIB group is divided into one or more discrete tables, the word "table" has a technical meaning.
An example is the section of this reference guide entitled Universal Unique Identifier (UUID).
The UUID object has a type and a value that uniquely identify an object such as a chassis. The table
defines all of the variables that comprise the managed object UUID.
The following table is an example of an SNMP table. The table contains variables that must occur in a
definite sequence. In the example table the defined variables are UUID Chassis Index, UUID Index,
UUID Type, and UUID Value.
Example SNMP Table
UUID Table
These objects comprise the Server Administrator definitions for the UUID.
Name
uUIDTable
Object ID
1.3.6.1.4.1.674.10892.1.300.20
Description
Defines the UUID table.
Syntax
SEQUENCE OF UUIDTableEntry
Access
Not accessible
UUID Table Entry
22
Name
uUIDTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.300.20.1
Description
Defines the UUID table entry.
Syntax
UUIDTableEntry
Access
Not accessible
Index
uUIDIndex, uUIDchassisIndex
Introduction
UUID Chassis Index
Name
uUIDchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.20.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
UUID Index
Name
uUIDIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.20.1.2
Description
Defines the index of the UUID in a specified chassis.
Syntax
DellObjectRange
Access
Read-only
UUID Type
Name
uUIDType
Object ID
1.3.6.1.4.1.674.10892.1.300.20.1.3
Description
Defines the type of the UUID for this chassis.
Syntax
DellUUIDType
Access
Read-only
UUID Value
Name
uUIDValue
Object ID
1.3.6.1.4.1.674.10892.1.300.20.1.4
Description
Defines the value of the UUID for this chassis.
Syntax
OCTET STRING (SIZE[16])
Access
Read-only
Introduction
23
Reference Guide Content Tables
NOTE: Variable values are defined for any variable that is Server Administrator-specific. Industry-standard
variable definitions are documented in "Standard Data Type Definitions."
Some of the tables in this guide have no technical significance in SNMP. These tables are designed to show
information in a readable form. The following table, for example, defines the Server Administrator-specific
variable, DellFanControlCapabilities. The table provides the name of the variable, its data type,
the values that are valid for the variable, and the meaning of each value.
Table 1-8. Example Variable Type Definition Table
Variable Name: DellFanControlCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
The fan’s capabilities are unknown.
lowSpeedCapable(2)
The fan can be set to low speed.
highSpeedCapable(4)
The fan can be set to high speed.
lowOrHighSpeedCapable(6)
The fan can be set to low or high speed.
This type of table is used throughout the reference guide to list and define variable values. Tables that
explain Server Administrator-specific variable values are located in the final section of sections that
define Server Administrator-specific variables. In the preceding example, the variable name is
DellFanControlCapabilities. This variable must be expressed as an integer and has four possible values:
unknown, lowSpeedCapable, highSpeedCapable, and lowOrHighSpeed Capable.
Section Organization
Sections in this reference guide are based on the Server Administrator MIBs, so the complexity of each
section depends on the complexity of each MIB group. The first section provides a high-level
introduction to the MIB group. If the group is defined by one or more tables, the second section lists
these tables. The third section documents the variables that comprise the group, and if applicable,
the variables that comprise the tables. The fourth section contains definitions for any Server
Administrator-specific variables that are used in the section. The following example shows the typical
content of these four sections.
1 BIOS Setup Control Group
This section explains the purpose of the MIB group and summarizes the major features of the
component groups.
2 BIOS Group Tables
If there is more than one SNMP table for a group, this section lists all of the tables. For this BIOS
group example, there are eight tables listed. In each section, double-clicking any table on the list takes
you to that table.
24
Introduction
•
BIOS Setup Control Table
•
SCSI Control Table
•
Parallel Port Control Table
•
Serial Port Control Table
•
USB Control Table
•
IDE Control Table
•
Diskette Control Table
•
Network Interface Control Table
3 Variables that make up each table in the group
This section documents the variables for the eight tables that comprise the BIOS group.
4 BIOS Variable Values
This section explains any Server Administrator-specific variables and data types that are used in this
section. In the BIOS group example, there are 17 unique, Server Administrator-specific variable
meanings. Information on each Server Administrator-specific variable is presented in a formatted table.
Other Documents You May Need
In addition to this Server Administrator SNMP Reference Guide, you can find the following guides on
your documentation CD:
•
The Server Administrator Messages Reference Guide lists the messages that you can receive on your
systems management console or on your operating system’s event viewer. This guide explains the text,
severity, and cause of each message that the server administrator issues.
•
Server Administrator CIM Reference Guide documents the Common Information Model (CIM) provider,
an extension of the standard management object format (MOF) file. The Server-Administrator
provider documents supported classes of management objects.
Introduction to the Server Administrator SNMP Subagent
This guide provides formatted information drawn primarily from the MIB files written for the
Server Administrator services that support the SNMP protocol.
For each of the variables defined in the MIBs, the following fields are specified:
•
Variable name
•
OID or unique identifying number
•
Description
•
Data type of the variable (for example: integer, string, octet string)
•
Whether the variable is accessible, not accessible, read-only, or read-write
•
Index or indexes, if applicable
Introduction
25
For each MIB group that has unique variable definitions, tables are included in the last section of the
section to explain the meaning of the terms.
Standards for writing MIBs are defined by the Internet Engineering Task Force (IETF). Structure of
Management Information (SMI) is a standard that specifies the rules for defining the structure and type
of managed objects and events in a MIB. SMIv1 is specified in Request For Comments (RFC) 1155.
The Server Administrator MIB conforms to the SMIv1 standard.
SNMP is a systems management standard originally designed for network management. SNMP manages
much more than networks. Information Technology (IT) professionals use SNMP for monitoring and
managing computer systems and the various components and peripherals supported by their systems.
SNMP standards are defined by the Internet Engineering Task Force (IETF). SNMP version 1 was
published in August 1988 and is the most commonly supported version of SNMP. SNMP version 2 was
first published in May 1993, but has not gained widespread market acceptance. SNMP version 3 was
recently completed and has addressed security issues that exist in version 1.
All SNMP systems consist of one or more managed systems that provide data through an SNMP agent to
a management system. The management system provides a user interface to view data from the
managed systems. The management system and managed systems communicate over a network
(typically through User Datagram Protocol/Internet Protocol [UDP/IP]).
The management system and a managed system communicate by means of a common data schema.
SNMP MIB files define the structure, type, and values of the SNMP data. While MIBs can be
standardized or enterprise specific, most operating systems supply SNMP agents for the standard MIB-I
and MIB-II schemas. MIB-I defines a base set of standard management information for systems
implementing the Internet Protocol (IP) suite. MIB-II defines characteristics of the system,
characteristics of network interfaces, and characteristics of components of the IP on the system.
In addition to the standard MIBs, many hardware vendors have defined MIBs that provide management
data specific to their systems and peripheral devices.
Monitored data can be retrieved through SNMP using the Get command. Typically, this command
requires the host name or IP address of the target machine as well as the OID of the data to retrieve.
Exact details are dependent on the operating system and the development tools being used to create the
management application. The Get command has a variant known as GetNext.
SNMP MIB OIDs
Each data class within an MIB is defined by an OID. OIDs are unique across all MIBs. An OID consists
of a series of digits separated by periods. The OID functions in a similar fashion to a phone number.
The phone number 011-512-471-0000 uniquely identifies a single phone. The phone number can be broken
down into a number of components to uniquely identify a phone. The first component, 011, is the
country code for the United States. The second component, 512, identifies the area code for central Texas.
The third component, 471, is the phone exchange for a large state university in the city of Austin.
The final component, 0000, is the main switchboard.
26
Introduction
There are two main differences between the phone number example and an actual OID. The first
difference is that there are many more components in an OID, up to 128. The combination of these
components is called an OID prefix. The second difference is that OIDs support the concept of indexes
or keys. The OID prefix specifies the data class but does not specify an instance of the data within the class.
Indexes can be used to identify the instances of a data class. These indexes are referred to as the OID suffix.
The assignment of values for each OID prefix component can be illustrated by using a tree structure.
The following is an example of an OID assignment:
ROOT
CCITT(0)
ISO(1)
ORG(3)
DOD(6)
INTERNET(1)
MGMT(2)
MIB(1)
EXPERIMENTAL(3)
PRIVATE(4)
ENTERPRISES(1)
DELL(674)
SNMPv2(6)
In the preceding example, the OID prefix for the Dell enterprise would be 1.3.6.1.4.1.674.
The numbers in boldface type show the categories and numbers that apply to Server Administrator.
All Server Administrator-defined OIDs consist of 1.3.6.1.4.1.674 followed by additional component values.
SNMP Security
SNMP version 1 has a very limited security mechanism. SNMP agents support the use of a community
string, which is configured at each SNMP agent and is passed as a part of all SNMP request messages.
There is no verification that the requester is actually a member of the specified community.
Because most system and network management data is not confidential, this limited security is
acceptable for Get types of requests. On the other hand, this security is not acceptable for Set types of
operations where an SNMP request could power off a system, reconfigure a redundant array of
independent disks (RAID) card, and so on. Some vendors have chosen not to support SNMP Set
operations for this reason. Server Administrator is able to support SNMP Set operations because its
Introduction
27
SNMP agents implement a hash/digest mechanism to prevent unauthorized SNMP Set operations.
One limitation of this practice is that only server administrator-developed SNMP management
applications have the capability to support the hash/digest mechanism.
NOTE: The default SNMP agent configuration usually includes a SNMP community name such as public. For
security reasons, change the SNMP community names from their default values. For information about changing
SNMP community names, see the Dell OpenManage Server Administrator User’s Guide. This guide is available on
the Dell Support website at support.dell.com and on the Dell PowerEdge Installation and Server Management and
Dell PowerEdge Documentation CDs. For additional guidelines, see the Securing an SNMP Environment article,
dated May 2003, in the Dell Power Solutions magazine. This magazine is also available at
www.dell.com/powersolutions.
NOTE: In Dell OpenManage Server Administrator version 5.2, SNMP Set operations are disabled by default. Server
Administrator provides support to enable or disable SNMP Set operations. For more information on enabling or
disabling SNMP Set operations in Server Administrator, see the Dell OpenManage Server Administrator User’s
Guide or the Dell OpenManage Server Administrator Command Line Interface User's Guide.
Management Actions
Management actions can be performed using the SNMP Set command. These actions can consist of
configuring a phone number for the system’s owner, rebooting a system, or changing the asset tag of the
system. See the previous section, "SNMP Security," for limitations on Set operations.
SNMP Traps
SNMP is frequently used to monitor systems for fault conditions such as temperature violations,
hard drive failures, and so on. Management applications can monitor for these conditions by polling the
appropriate OIDs with the Get command and analyzing the returned data. This method has its
drawbacks. If it is done frequently, significant amounts of network bandwidth can be consumed. If it is
done infrequently, the response to the fault condition may not occur in a timely fashion. SNMP traps
avoid these limitations of the polling method.
An SNMP trap is an asynchronous event indicating that something significant has occurred. This is
analogous to a pager receiving an important message, except that the SNMP trap frequently contains all
the information needed to diagnose a fault.
Two drawbacks to SNMP traps are that they are sent using UDP, which is not a guaranteed delivery
mechanism, and that they are not acknowledged by the receiver.
An SNMP trap message contains the trap’s enterprise OID, the agent IP address, a generic trap ID, the
specific trap ID, a time stamp, and zero or more variable bindings (varbinds). The combination of an
enterprise OID and a specific trap ID uniquely identifies each Server Administrator-defined trap.
A varbind consists of an OID and its value and provides additional information about the trap.
In order for a management system to receive SNMP traps from a managed system, the node must be
configured to send traps to the management system. Trap destination configuration is dependent on the
operating system. When this configuration is done, a management application on the management
system can wait for traps and act on them when received.
For a list of traps supported by the server administrator SNMP subagent, see "Traps."
28
Introduction
Instrumentation MIB Version Group
The Instrumentation Management Information Base (MIB) Version Group defines the attributes
that identify the version of the Instrumentation MIB supported by the systems
management software.
The mIBMajorVersionNumber, mIBMinorVersionNumber, and mIBMaintenanceVersionNumber
attributes are scalar objects, meaning that they are not related to other MIB objects and are thus not
placed in a table.
MIB Major Version Number
Name
mIBMajorVersionNumber
Object ID
1.3.6.1.4.1.674.10892.1.1.1.0
Description
Defines the major version number of the version of this MIB
supported by the systems management software. For example, if the
MIB version is 1.2.3, the major version number is 1.
A major version number change indicates a major change in object
functionality.
Syntax
DellUnsigned8BitRange
Access
Read-only
MIB Minor Version Number
Name
mIBMinorVersionNumber
Object ID
1.3.6.1.4.1.674.10892.1.1.2.0
Description
Defines the minor version number of the version of this MIB
supported by the systems management software. For example, if the
MIB version is 1.2.3, the minor version number is 2.
A minor revision provides additional support for new objects as well
as problem fixes.
Syntax
DellUnsigned8BitRange
Access
Read-only
Instrumentation MIB Version Group
29
MIB Maintenance Version Number
30
Name
mIBMaintenanceVersionNumber
Object ID
1.3.6.1.4.1.674.10892.1.1.3.0
Description
Defines the maintenance version number for the version of this MIB
supported by the systems management software. For example, if the
MIB version is 1.2.3, the maintenance version number is 3.
Syntax
DellUnsigned8BitRange
Access
Read-only
Instrumentation MIB Version Group
Systems Management Software Group
The Systems Management Software Group allows users to see information about the standards and
software that are supported by the agent of a particular managed computer chassis. The Systems
Management Software Group classifies each computer chassis according to the systems
management standard that the agent supports.
Additional objects define the universal resource locator (URL) of the systems management software
and the language in which systems management information displays. Defining these objects
enables users to manage a system using an internet browser. You can access Server Administrator
using the secure hypertext transfer protocol (https) and a pre-assigned port number of 1311, or you
can specify a port number of your own choosing.
NOTE: Using the Software → Server Preferences menu of Server Administrator, you can bind to either one
IP address or to all IP addresses.
NOTE: To manage a system remotely using Server Administrator, type one of the following in the address field
of your browser:
https://<systemname>:<1311 or user specified port number>
or
https://<IP address>:<1311 or user specified port number>
To manage a system locally using Server Administrator, type the following in the address field of
your browser:
https://localhost:<1311 or user-specified port number>
Systems Management Software
The following objects describe the fields for server administrator systems management information.
The systems management software variables are scalar objects, meaning that they are not related to
other management information base (MIB) objects and are thus not placed in a table.
Systems Management Software Group
31
Systems Management Software Name
Name
systemManagementSoftwareName
Object ID
1.3.6.1.4.1.674.10892.1.100.1
Description
Defines the systems management software product name.
Syntax
DellString
Access
Read-only
Systems Management Software Version Number Name
Name
systemManagementSoftwareVersionNumberName
Object ID
1.3.6.1.4.1.674.10892.1.100.2
Description
Defines the version number of the systems management software.
Syntax
DellString
Access
Read-only
Systems Management Software Build Number
Name
systemManagementSoftwareBuildNumber
Object ID
1.3.6.1.4.1.674.10892.1.100.3
Description
Defines the build number of the systems management software.
Syntax
DellUnsigned16BitRange
Access
Read-only
Systems Management Software Description Name
32
Name
systemManagementSoftwareDescriptionName
Object ID
1.3.6.1.4.1.674.10892.1.100.4
Description
Defines the description of the systems management software.
Syntax
DellString
Access
Read-only
Systems Management Software Group
Systems Management Software Supported Protocol
Name
systemManagementSoftwareSupportedProtocol
Object ID
1.3.6.1.4.1.674.10892.1.100.5
Description
Defines the systems management standards (SNMP or CIM)
supported by the systems management software.
Syntax
SMSSupportedTypes (See Table 3-1.)
Access
Read-only
Systems Management Software Preferred Protocol
Name
systemManagementSoftwarePreferredProtocol
Object ID
1.3.6.1.4.1.674.10892.1.100.6
Description
Defines the preferred systems management standard for the systems
management software.
Syntax
SMSSupportedTypes (See Table 3-1.)
Access
Read-only
Systems Management Software Update Level Name
Name
systemManagementSoftwareUpdateLevelName
Object ID
1.3.6.1.4.1.674.10892.1.100.7
Description
Defines the update level of the system management software.
Syntax
DellString
Access
Read-only
Systems Management Software URL Name
Name
systemManagementSoftwareURLName
Object ID
1.3.6.1.4.1.674.10892.1.100.8
Description
Defines the universal resource locator (URL) of the systems
management software.
Syntax
DisplayString (SIZE (0..1024))
Access
Read-only
Systems Management Software Group
33
Systems Management Software Language Name
Name
systemManagementSoftwareLanguageName
Object ID
1.3.6.1.4.1.674.10892.1.100.9
Description
Defines the language of the systems management software.
Syntax
DisplayString (SIZE (0..255))
Access
Read-only
Systems Management Software Global Version Name
Name
systemManagementSoftwareGlobalVersionName
Object ID
1.3.6.1.4.1.674.10892.1.100.10
Description
Defines the global version of the systems management software.
Syntax
DellString
Access
Read-only
Systems Management Software Feature Flags
Name
systemManagementSoftwareFeatureFlags
Object ID
1.3.6.1.4.1.674.10892.1.100.11
Description
Defines the features of the systems management software.
Syntax
SMSFeatureFlags (See Table 3-2)
Access
Read-only
Systems Management Software SNMP Agent Feature Flags
34
Name
systemManagementSoftwareSNMPAgentFeatureFlags
Object ID
1.3.6.1.4.1.674.10892.1.100.12
Description
Defines the features of the SNMP agent software provided by the
operating system.
Syntax
SMSSNMPAgentFeatureFlags (See Table 3-3)
Access
Read-only
Systems Management Software Group
Systems Management Software Manufacturer Name
Name
systemManagementSoftwareManufacturerName
Object ID
1.3.6.1.4.1.674.10892.1.100.13
Description
Defines the manufacturer of the systems management software.
Syntax
DellString
Access
Read-only
Systems Management Software Variable Values
This section includes definitions of server administrator-specific variable values used in this section.
Table 3-1.
Systems Management Software Supported Standards
Variable Name: SMSSupportedTypes
Data Type: Integer
Possible Data Values
Meaning of Data Value
supportsSNMP(1)
This system supports SNMP.
supportsDMI(2)
This system supports DMI.
supportsSNMPandDMI(3)
This system supports SNMP and DMI.
supportsCIMOM(4)
This system supports CIM.
supportsSNMPandCIMOM(5)
This system supports SNMP and CIM.
Table 3-2.
Systems Management Software Feature Flags
Variable Name: SMSFeatureFlags
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The Systems Management Software features are
not enabled.
webOneToOneManagementPreferred(1)
The web 1:1 management preferred feature is
enabled.
Systems Management Software Group
35
Table 3-3.
Systems Management Software SNMP Agent Feature Flags
Variable Name: SMSSNMPAgentFeatureFlags
Data Type: Integer
36
Possible Data Values
Meaning of Data Value
none(0)
The Systems Management Software SNMP agent
features are not enabled.
supportsSparseTables(1)
The SNMP agent supports sparse tables.
Systems Management Software Group
System State Group
The Management Information Base (MIB) variables presented in this section enable you to track
various attributes that describe the state of the critical components supported by your system.
Components monitored under the System State Group include power supplies, AC power cords,
AC power switches, and cooling devices, as well as temperature, fan, amperage, and voltage probes.
System State Group Table
The System State Group defines objects in the System State MIB table.
System State Table
The following object sets up the System State Table:
Name
systemStateTable
Object ID
1.3.6.1.4.1.674.10892.1.200.10
Description
Defines the System State Table.
Syntax
SEQUENCE OF SystemStateTableEntry
Access
Not accessible
System State Table Entry
Name
systemStateTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1
Description
Defines the System State Table entry.
Syntax
SystemStateTableEntry
Access
Not accessible
Index
systemStatechassisIndex
System State Group
37
System State Chassis Index
Name
systemStatechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
System State Global System Status
Name
systemStateGlobalSystemStatus
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.2
Description
Defines the global system status of all chassis being monitored by this
instrumentation instance.
Syntax
DellStatus
Access
Read-only
System State Chassis State
Name
systemStateChassisState
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.3
Description
Defines the system state of this chassis.
Syntax
DellStateSettings
Access
Read-only
System State Chassis Status
38
Name
systemStateChassisStatus
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.4
Description
Defines the system status of this chassis.
Syntax
DellStatus
Access
Read-only
System State Group
System State Power Unit State Details
Name
systemStatePowerUnitStateDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.5
Description
Defines the state of all power units in this chassis. The results are returned as a binary octet
string. Each byte of the octet string represents the state of a specific power unit. The first byte
returned represents the state of the first power unit, the second byte returned represents the
state of the second power unit, and so on. The bytes have the same definition type as
DellStateSettings.
Syntax
OCTET STRING (SIZE(1..128))
Access
Read-only
System State Power Unit Status Redundancy
Name
systemStatePowerUnitStatusRedundancy
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.6
Description
Defines the system status of the power unit(s) in this chassis.
Syntax
DellStatus
Access
Read-only
System State Power Unit Status Details
Name
systemStatePowerUnitStatusDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.7
Description
Defines the status of all power units in this chassis. The results are returned as a binary octet
string. Each byte of the octet string represents the status of a specific power unit. The first byte
returned represents the status of the first power unit, the second byte returned represents the
status of the second power unit, and so on. The bytes have the same definition type as
DellStatusRedundancy.
Syntax
OCTET STRING (SIZE(1..128))
Access
Read-only
System State Group
39
System State Power Supply State Details
Name
systemStatePowerSupplyStateDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.8
Description
Defines the state of all power supplies in this chassis. The results are returned as a binary octet
string. Each byte of the octet string represents the state of a specific power supply. The first byte
returned represents the state of the first power supply, the second byte returned represents the
state of the second power supply, and so on. The bytes have the same definition type as
DellStateSettings.
Syntax
OCTET STRING (SIZE(1..128))
Access
Read-only
System State Power Supply Status Combined
Name
systemStatePowerSupplyStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.9
Description
Defines the status of all power supplies in this chassis.
Syntax
DellStatus
Access
Read-only
System State Power Supply Status Details
40
Name
systemStatePowerSupplyStatusDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.10
Description
Defines the status of all power supplies in this chassis. The results are returned as a binary
octet string, Each byte of the octet string represents the status of a specific power supply.
The first byte returned represents the status of the first power supply, the second byte
returned represents the status of the second power supply, and so on. The bytes have the
same definition type as DellStatus.
Syntax
OCTET STRING (SIZE(1..128))
Access
Read-only
System State Group
System State Voltage State Details
Name
systemStateVoltageStateDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.11
Description
Defines the state of all voltage probes in this chassis. The results are returned as a binary octet
string. Each byte of the octet string represents the status of a specific voltage probe. The first byte
returned represents the status of the first voltage probe, the second byte returned represents
the status of the second voltage probe, and so on. The bytes have the same definition type as
DellStateSettings.
Syntax
OCTET STRING (SIZE(1..128))
Access
Read-only
System State Voltage Status Combined
Name
systemStateVoltageStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.12
Description
Defines the status of all voltage probes in this chassis.
Syntax
DellStatus
Access
Read-only
System State Voltage Status Details
Name
systemStateVoltageStatusDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.13
Description
Defines the status of all voltage probes in this chassis.
Syntax
OCTET STRING (SIZE(1..128))
Access
Read-only
System State Group
41
System State Amperage State Details
Name
systemStateAmperageStateDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.14
Description
Defines the state of all current probes in this chassis. The results are returned as a binary octet
string. Each byte of the octet string represents the status of a specific current probe. The
first byte returned represents the state of the first current probe, the second byte returned
represents the state of the second current probe, and so on. The bytes have the same
definition type as DellStateSettings.
Syntax
OCTET STRING (SIZE(1..128))
Access
Read-only
System State Amperage Status Combined
Name
systemStateAmperageStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.15
Description
Defines the status of all amperage probes in this chassis. The result is returned as a combined
status value. The value has the same definition type as DellStatus.
Syntax
DellStatus
Access
Read-only
System State Amperage Status Details
42
Name
systemStateAmperageStatusDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.16
Description
Defines the status of all amperage probes in this chassis. The results are returned as a binary
octet string. Each byte of the octet string represents the status of a specific amperage probe.
The first byte returned represents the status of the first amperage probe, the second byte
returned represents the status of the second amperage probe, and so on. The bytes have the
same definition type as DellStatus.
Syntax
OCTET STRING (SIZE(1..128))
Access
Read-only
System State Group
System State Cooling Unit State Details
Name
statesystemStateCoolingUnitStateDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.17
Description
Defines the state of all cooling units in this chassis. The results are returned as a binary octet
string. Each byte of the octet string represents the state of a specific cooling unit. The first
byte returned represents the state of the first cooling unit, the second byte returned represents
the state of the second cooling unit, and so on. The bytes have the same definition type as
DellStateSettings.
Syntax
OCTET STRING (SIZE(1..128))
Access
Read-only
System State Cooling Unit Status Redundancy
Name
systemStateCoolingUnitStatusRedundancy
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.18
Description
Defines the state of all cooling units in this chassis.
Syntax
DellStatusRedundancy
Access
Read-only
System State Cooling Unit State Details
Name
systemStateCoolingUnitstateDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.19
Description
Defines the state of all cooling units in this chassis. The results are returned as a binary octet
string. Each byte of the octet string represents the state of a specific cooling unit. The first
byte returned represents the state of the first cooling unit, the second byte returned represents
the state of the second cooling unit, and so on. The bytes have the same definition type as
DellStateSettings.
Syntax
OCTET STRING (SIZE(1..128))
Access
Read-only
System State Group
43
System State Cooling Device State Details
Name
systemStateCoolingDeviceStateDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.20
Description
Defines the state of all cooling devices in this chassis. The results are returned as a binary octet
string. Each byte of the octet string represents the state of a specific cooling device. The first byte
returned represents the state of the first cooling device, the second byte returned represents
the state of the second cooling device, and so on. The bytes have the same definition type as
DellStateSettings.
Syntax
OCTET STRING (SIZE(1..128))
Access
Read-only
System State Cooling Device Status Combined
Name
systemStateCoolingDeviceStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.21
Description
This attribute defines the cooling device status of all cooling devices in this chassis.
The results is returned as a combined status value. The value has the same definition type
as DellStatus.
Syntax
DellStatus
Access
Read-only
System State Cooling Device Status Details
44
Name
systemStateCoolingDeviceStatusDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.22
Description
Defines the status of all cooling devices in this chassis. The results are returned as a binary
octet string. Each byte of the octet string represents the status of a specific cooling device.
The first byte returned represents the status of the first cooling device, the second byte
returned represents the status of the second cooling device, and so on. The bytes have the
same definition type as DellStatus.
Syntax
OCTET STRING (SIZE(1..128))
Access
Read-only
System State Group
System State Temperature State Details
Name
systemStateTemperatureStateDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.23
Description
Defines the state of all temperature probes in this chassis. The results are returned as a binary
octet string. Each byte of the octet string represents the state of a specific temperature probe.
The first byte returned represents the state of the first temperature probe, the second byte
returned represents the status of the second temperature probe, and so on. The bytes have the
same definition type as DellStateSettings.
Syntax
OCTET STRING (SIZE(1..128))
Access
Read-only
System State Temperature Status Combined
Name
systemStateTemperatureStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.24
Description
Defines the status of all temperature probes in this chassis. The result is returned as a
combined status value. The value has the same definition type as DellStatus.
Syntax
DellStatus
Access
Read-only
System State Temperature Status Details
Name
systemStateTemperatureStatusDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.25
Description
Defines the status of all temperature probes in this chassis. The first byte returned represents
the status of the first temperature probe, the second byte returned represents the status of the
second temperature probe, and so on.
Syntax
OCTET STRING (SIZE(1..128)
Access
Read-only
System State Group
45
System State Memory Device State Details
Name
systemStateMemoryDeviceStateDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.26
Description
Defines the state of all memory devices in this chassis. The results are returned as a binary
octet string. Each byte of the octet string represents the state of the specific memory device.
The first byte returned represents the state of the first memory device, the second byte
returned represents the status of the second memory device, and so on. The bytes have the
same definition type as DellStateSettings.
Syntax
OCTET STRING (SIZE(1..128)
Access
Read-only
System State Memory Device Status Combined
Name
systemStateMemoryDeviceStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.27
Description
Defines the status of all memory devices in this chassis.
Syntax
DellStatus
Access
Read-only
System State Memory Device Status Details
46
Name
systemStateMemoryDeviceStatusDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.28
Description
Defines the status of all memory devices in this chassis. The results are returned as a binary
octet string. Each byte of the octet string represents the status of a specific memory device.
The first byte returned represents the status of the first memory device, the second byte
returned represents the status of the second memory device, and so on. The bytes have the
same definition type as DellStatus.
Syntax
OCTET STRING (SIZE(1..128)
Access
Read-only
System State Group
System State Chassis Intrusion State Details
Name
systemStateChassisIntrusionStateDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.29
Description
Defines the intrusion state of all intrusion detection devices in this chassis. The results are
returned as a binary octet string. Each byte of the octet string represents the status of a specific
intrusion detection device. The first byte returned represents the status of the first intrusion
detection device, the second byte returned represents the status of the second intrusion
detection device, and so on. The bytes have the same definition type as DellStateSettings.
Syntax
OCTET STRING (SIZE(1..128)
Access
Read-only
System State Chassis Intrusion Status Combined
Name
systemStateChassisIntrusionStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.30
Description
Defines the intrusion status of all intrusion detection devices in this chassis. The result is
returned as a combined status value. The value has the same definition type as DellStatus.
Syntax
DellStatus
Access
Read-only
System State Chassis Intrusion Status Details
Name
systemStateChassisIntrusionStatusDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.31
Description
Defines the intrusion status of all intrusion detection devices in this chassis. The first byte
returned represents the status of the first intrusion detection device, the second byte returned
represents the status of the second intrusion detection device, and so on.
Syntax
OCTET STRING (SIZE(1..128))
Access
Read-only
System State Group
47
System State AC Power Switch State Details
Name
systemStateACPowerSwitchStateDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.32
Description
Defines the individual state of all AC power switches in this chassis. The first byte returned
represents the state of the first AC power switch, the second byte returned represents the state
of the second AC power switch, and so on.
Syntax
OCTET STRING (SIZE(1..128))
Access
Read-only
System State AC Power Switch Status Redundancy
Name
systemStateACPowerSwitchStatusRedundancy
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.33
Description
Defines the overall redundancy status of the AC power switches in this chassis.
Syntax
DellStatusRedundancy
Access
Read-only
System State AC Power Switch Status Details
Name
systemStateACPowerSwitchStatusDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.34
Description
Defines the individual status of all AC power switches in this chassis. The first byte returned
represents the status of the first AC power switch, the second byte returned represents the
status of the second AC power switch, and so on.
Syntax
OCTET STRING (SIZE(1..128))
Access
Read-only
System State AC Power Cord State Details
48
Name
systemStateACPowerCordStateDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.35
Description
Defines the individual state of all AC power cords for any AC power switches in this chassis.
The first byte returned represents the state of the first AC power cord, the second byte
returned represents the state of the second AC power cord, and so on.
Syntax
OCTET STRING (SIZE(1..128))
Access
Read-only
System State Group
System State AC Power Cord Status Combined
Name
systemStateACPowerCordStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.36
Description
Defines the overall status of all AC power cords for any AC power switches in this chassis.
Syntax
DellStatus
Access
Read-only
System State AC Power Cord Status Details
Name
systemStateACPowerCordStatusDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.37
Description
Defines the individual status of all AC power cords for any AC power switches in this chassis.
The first byte returned represents the status of the first AC power cord, the second byte
returned represents the status of the second AC power cord, and so on.
Syntax
OCTET STRING (SIZE(1..128))
Access
Read-only
System State Redundant Memory Unit State Details
Name
systemStateRedundantMemoryUnitStateDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.38
Description
Defines the state of all redundant memory units in this chassis. The results are returned as a
binary octet string, each byte of the octet string represents the state of the specific object. The
first byte returned represents the state of the first object, and so on. The bytes have the same
definition type as DellStateSettings.
Syntax
OCTET STRING (SIZE(1..128))
Access
Read-only
System State Redundant Memory Unit Status Redundancy
Name
systemStateRedundantMemoryUnitStatusRedundancy
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.39
Description
Defines the overall redundancy status for redundant memory.
Syntax
DellStatusRedundancy
Access
Read-only
System State Group
49
System State Redundant Memory Unit Status Details
Name
systemStateRedundantMemoryUnitStatusDetails
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.40
Description
Defines the status of all redundant memory units in this chassis. The results are returned as a
binary octet string, each byte of the octet string represents the status of the specific object.
The first byte returned represents the status of the first object, and so on. The bytes have the
same definition type as DellStatusRedundancy.
Syntax
OCTET STRING (SIZE(1..128))
Access
Read-only
System State Event Log Status
Name
systemStateEventLogStatus
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.41
Description
Defines the overall status of this chassis (ESM) event log.
Syntax
DellStatus
Access
Read-only
System State Power Unit Status Combined
Name
systemStatePowerUnitStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.42
Description
Defines the combined status of all power units of this chassis.
Syntax
DellStatus
Access
Read-only
System State Power Unit Status List
50
Name
systemStatePowerUnitStatusList
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.43
Description
Lists the status of each power unit of this chassis. The results are returned as a binary octet
string where each byte of the octet string represents the status of a power unit. The first byte
returned represents the status of the first power unit, and so on. The bytes have the same
definition type as DellStatus.
Syntax
OCTET STRING (SIZE(1..128))
Access
Read-only
System State Group
System State Cooling Unit Status Combined
Name
systemStateCoolingUnitStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.44
Description
Defines the combined status of all cooling units of this chassis.
Syntax
DellStatus
Access
Read-only
System State Cooling Unit Status List
Name
systemStateCoolingUnitStatusList
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.45
Description
Lists the status of each cooling unit of this chassis. The results are returned as a binary octet
string where each byte of the octet string represents the status of a cooling unit. The first byte
returned represents the status of the first cooling unit, and so on. The bytes have the same
definition type as DellStatus.
Syntax
OCTET STRING (SIZE(1..128))
Access
Read-only
System State AC Power Switch Status Combined
Name
systemStateACPowerSwitchStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.46
Description
Defines the combined status of all AC power switches of this chassis.
Syntax
DellStatus
Access
Read-only
System State AC Power Switch Status List
Name
systemStateACPowerSwitchStatusList
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.47
Description
Lists the status of each AC power switch of this chassis. The results are returned as a binary
octet string where each byte of the octet string represents the status of an AC power switch.
The first byte returned represents the status of the first AC power switch, and so on. The bytes
have the same definition type as DellStatus.
Syntax
OCTET STRING (SIZE(1..128))
Access
Read-only
System State Group
51
System State Redundant Memory Unit Status Combined
Name
systemStateRedundantMemoryUnitStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.48
Description
Defines the combined status of all redundant memory units of this chassis.
Syntax
DellStatus
Access
Read-only
System State Redundant Memory Unit Status List
Name
systemStateRedundantMemoryUnitStatusList
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.49
Description
Lists the status of each redundant memory unit of this chassis. The results are returned as a
binary octet string where each byte of the octet string represents the status of a redundant
memory unit. The first byte returned represents the status of the first redundant memory
unit, and so on. The bytes have the same definition type as DellStatus.
Syntax
OCTET STRING (SIZE(1..128))
Access
Read-only
System State Processor Device Status Combined
Name
systemStateProcessorDeviceStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.50
Description
Defines the combined status of all processor devices of this chassis.
Syntax
DellStatus
Access
Read-only
System State Processor Device Status List
52
Name
systemStateProcessorDeviceStatusList
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.51
Description
Lists the status of each processor device of this chassis. The results are returned as a binary
octet string where each byte of the octet string represents the status of a processor device.
The first byte returned represents the status of the first processor device, and so on. The bytes
have the same definition type as DellStatus.
Syntax
OCTET STRING (SIZE(1..128))
Access
Read-only
System State Group
System State Battery Status Combined
Name
systemStateBatteryStatusCombined
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.52
Description
Defines the combined status of all batteries of this chassis.
Syntax
DellStatus
Access
Read-only
System State Battery Status List
Name
systemStateBatteryStatusList
Object ID
1.3.6.1.4.1.674.10892.1.200.10.1.53
Description
Lists the status of each battery of this chassis. The results are returned as a binary octet string
where each byte of the octet string represents the status of a battery. The first byte returned
represents the status of the first battery, and so on. The bytes have the same definition type
as DellStatus.
Syntax
OCTET STRING (SIZE(1..128))
Access
Read-only
System State Group
53
54
System State Group
Chassis Information Group
The Chassis Information Group provides information about the type or types of chassis in your system,
as well as information about the light-emitting diode (LED) indicators and settings for devices on
each chassis. Information is also available about the current date and time displayed on the chassis,
intrusion warnings, watchdog timer, systems management basic input/output system (SMBIOS),
and so on.
Chassis Information Group Tables
The following management information base (MIB) tables define the objects in the Chassis
Information Group:
•
Chassis Information Table
•
UUID Table
•
POST Log Table
•
Event Log Table
•
System BIOS Table
•
Firmware Table
•
Intrusion Table
•
Baseboard Table
Chassis Information Table
The following object sets up the Chassis Information Table.
Name
chassisInformationTable
Object ID
1.3.6.1.4.1.674.10892.1.300.10
Description
Defines the chassis information table.
Syntax
SEQUENCE OF ChassisInformationTableEntry
Access
Not accessible
Chassis Information Group
55
Chassis Information Table Entry
Name
chassisInformationTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1
Description
Defines the chassis information table entry.
Syntax
ChassisInformationTableEntry
Access
Not accessible
Index
chassisIndexChassisInformation
Chassis Index Chassis Information
Name
chassisIndexChassisInformation
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.1
Description
Defines the index (one-based) of this chassis. The first chassis will be
numbered one.
Syntax
DellObjectRange
Access
Read-only
Chassis State Capabilities
Name
chassisStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.2
Description
Defines the capabilities of the chassis.
Syntax
DellStateCapabilities
Access
Read-only
Chassis State Settings
56
Name
chassisStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.3
Description
Defines the state settings for the chassis.
Syntax
DellStateSettings
Access
Read-write
Chassis Information Group
Chassis Status
Name
chassisStatus
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.4
Description
Defines the status of the chassis.
Syntax
DellStatus
Access
Read-only
Chassis Parent Index Reference
Name
chassisparentIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.4
Description
Defines the index (one-based) of the parent chassis of this chassis,
if any. A zero (0) means that this chassis is the parent of all other
chassis managed by the Server Administrator.
Syntax
DellObjectRange
Access
Read-only
Chassis Type
Name
chassisType
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.6
Description
Defines the chassis type.
Syntax
DellChassisType (See Table 5-2.)
Access
Read-only
Chassis Name
Name
chassisName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.7
Description
Defines the user-assigned chassis name of the chassis.
Syntax
DellString
Access
Read-write
Chassis Information Group
57
Chassis Manufacturer Name
Name
chassisManufacturerName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.8
Description
Defines the manufacturer’s name for this chassis.
Syntax
DellString
Access
Read-only
Chassis Model Name
Name
chassisModelName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.9
Description
Defines the system model type for this chassis.
Syntax
DellString
Access
Read-only
Chassis Asset Tag Name
Name
chassisAssetTagName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.10
Description
Defines the user-assigned asset tag name for this chassis.
Syntax
DisplayString (SIZE (0..10))
Access
Read-write
Chassis Service Tag Name
58
Name
chassisServiceTagName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.11
Description
Defines the service tag name for this chassis.
Syntax
DisplayString (SIZE (0..7))
Access
Read-only
Chassis Information Group
Chassis ID
Name
chassisID
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.12
Description
Defines the asset tag name for this chassis.
Syntax
DellUnsigned8BitRange
Access
Read-only
Chassis ID Extension
Name
chassisIDExtension
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.13
Description
Defines the SMBIOS machine ID of this chassis.
Syntax
DellUnsigned16BitRange
Access
Read-only
Chassis System Class
Name
chassisSystemClass
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.14
Description
Defines the chassis class of this chassis.
Syntax
DellChassisSystemClass (See Table 5-20.)
Access
Read-only
Chassis System Name
Name
chassisSystemName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.15
Description
Defines the system name of this chassis.
Syntax
DellString
Access
Read-only
Chassis Information Group
59
Chassis System Boot Date Name
Name
chassisSystemBootDateName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.16
Description
Defines the boot time of this system.
Syntax
DellDateName
Access
Read-only
Chassis System Date Name
Name
chassisSystemDateName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.17
Description
Defines the current time on this system.
Syntax
DellDateName
Access
Read-only
Chassis System Location Name
Name
chassisSystemLocationName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.18
Description
Defines the user-assigned location for this chassis.
Syntax
DellString
Access
Read-write
Chassis System Primary User Name
60
Name
chassisSystemPrimaryUserName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.19
Description
Defines the user-assigned primary user name for this chassis.
Syntax
DellString
Access
Read-write
Chassis Information Group
Chassis System User Phone Number Name
Name
chassisSystemUserPhoneNumberName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.20
Description
Defines the user-assigned phone number of the primary user of the
system.
Syntax
DellString
Access
Read-write
Chassis Connection Status Unique
Name
chassisConnectionStatusUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.21
Description
Defines the status of the connection from the system chassis to an
expansion chassis.
Syntax
DellConnectionStatus (See Table 5-3.)
Access
Read-only
Chassis Fan Control Capabilities Unique
Name
chassisFanControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.22
Description
Defines the capabilities of the fan control function in this chassis.
Syntax
DellFanControlCapabilities (See Table 5-4.)
Access
Read-only
Chassis Fan Control Settings Unique
Name
chassisFanControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.23
Description
Defines the readings and settings of the fan control hardware in
the chassis.
Syntax
DellFanControlSettings
Access
Read-write
Chassis Information Group
61
Chassis LED Control Capabilities Unique
Name
chassisLEDControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.24
Description
Defines the capabilities of the LED control function in the chassis.
Syntax
DellLEDControlCapabilities (See Table 5-5.)
Access
Read-only
Chassis LED Control Settings Unique
Name
chassisLEDControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.25
Description
Defines the readings and settings of the LED control hardware in the
chassis.
Syntax
DellLEDControlSettings (See Table 5-6.)
Access
Read-write
Chassis Hard-Drive (HD) Fault Clear Control Capabilities
Name
chassisHDFaultClearControlCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.26
Description
Specifies whether the chassis allows reset of the chassis hard-drive
fault LED.
Syntax
DellHDFaultLEDControlCapabilities (See Table 5-7.)
Access
Read-only
Chassis HD Fault Clear Control Settings
62
Name
chassisHDFaultClearControlSettings
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.27
Description
Allows reset of the chassis hard-drive fault LED.
Syntax
DellHDFaultLEDControlSettings (See Table 5-8.)
Access
Read-write
Chassis Information Group
Chassis Identify Flash Control Capabilities
Name
chassisIdentifyFlashControlCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.28
Description
Specifies whether the chassis front-panel LED can be set to flash.
Syntax
DellChassisIdentifyControlCapabilities (See Table 5-9.)
Access
Read-only
Chassis Identify Flash Control Settings
Name
chassisIdentifyFlashControlSettings
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.29
Description
Causes the chassis front-panel LED to flash.
Syntax
DellChassisIdentifyControlSettings (See Table 5-10.)
Access
Read-write
Chassis Lock Present
Name
chassisLockPresent
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.30
Description
Specifies whether a chassis lock is present on the chassis.
Syntax
DellBoolean
Access
Read-only
Chassis Host Control Capabilities Unique
Name
chassishostControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.31
Description
Defines the capabilities of the host control object.
Syntax
DellHostControlCapabilities (See Table 5-11.)
Access
Read-only
Chassis Information Group
63
Chassis Host Control Settings Unique
Name
chassishostControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.32
Description
Defines the current settings of the host control object.
Syntax
DellHostControlSettings (See Table 5-12.)
Access
Read-write
Chassis Watchdog Control Capabilities Unique
Name
chassiswatchDogControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.33
Description
Defines the capabilities of the watchdog timer object.
Syntax
DellWatchDogControlCapabilities (See Table 5-13.)
Access
Read-only
Chassis Watchdog Control Settings Unique
Name
chassiswatchDogControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.34
Description
Defines the current settings and the values allowed to be set for the
watchdog timer object.
Syntax
DellWatchDogControlCapabilities (See Table 5-13.)
Access
Read-write
Chassis Watchdog Control Expiry Time Capabilities Unique
64
Name
chassiswatchDogControlExpiryTimeCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.35
Description
Defines the capabilities of the watchdog expiry timer object.
Syntax
DellWatchDogTimerCapabilities (See Table 5-13.)
Access
Read-only
Chassis Information Group
Chassis Watchdog Control Expiry Time
Name
chassiswatchDogControlExpiryTime
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.36
Description
Defines the current reading and allows setting of the nonrecoverable
watchdog expiry timer object.
Syntax
DellUnsigned16BitRange
Access
Read-write
Chassis Allow Set Commands From SNMP
Name
chassisallowSETCommandsfromSNMP
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.37
Description
Specifies whether Simple Network Management Protocol (SNMP) Set type
commands are allowed by Server Administrator.
This attribute does not reflect whether SNMP Set type commands are
allowed by the SNMP master agent.
Syntax
DellBoolean
Access
Read-only
Chassis Power Button Control Capabilities Unique
Name
chassisPowerButtonControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.38
Description
Defines the capabilities of the power button control function.
Syntax
DellPowerButtonControlCapabilities (See Table 5-16)
Access
Read-only
Chassis Power Button Control Settings Unique
Name
chassisPowerButtonControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.39
Description
Defines the current reading and allows setting of the power button
control hardware.
Syntax
DellPowerButtonControlSettings (See Table 5-17)
Access
Read-write
Chassis Information Group
65
Chassis Reseller Name
Name
chassisResellerName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.40
Description
Defines the name of the chassis reseller.
Syntax
DisplayString (SIZE (0..128))
Access
Read-only
Chassis Reseller Contact Information Name
Name
chassisResellerContactInformationName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.41
Description
Defines the chassis reseller contact information name.
Syntax
DisplayString (SIZE (0..128))
Access
Read-only
Chassis Reseller Product Name
Name
chassisResellerProductName
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.42
Description
Defines the chassis reseller product name.
Syntax
DisplayString (SIZE (0..128))
Access
Read-only
Chassis Reseller System ID
66
Name
chassisResellerSystemID
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.43
Description
Defines the chassis reseller system ID.
Syntax
DellUnsigned16BitRange
Access
Read-only
Chassis Information Group
Chassis NMI Button Control Capabilities Unique
Name
chassisNMIButtonControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.44
Description
Defines the capabilities of the NMI button control function.
Syntax
DellNMIButtonControlCapabilities (See Table 5-18)
Access
Read-only
Chassis NMI Button Control Settings Unique
Name
chassisNMIButtonControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.10.1.45
Description
Defines the current reading and allows setting of the NMI button
control hardware.
Syntax
DellNMIButtonControlSettings (See Table 5-19)
Access
Read-write
UUID Table
These objects comprise the server administrator definitions for the Universal Unique Identifier (UUID).
Name
uUIDTable
Object ID
1.3.6.1.4.1.674.10892.1.300.20
Description
Defines the UUID table.
Syntax
SEQUENCE OF UUIDTableEntry
Access
Not accessible
UUID Table Entry
Name
uUIDTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.300.20.1
Description
Defines the UUID table entry.
Syntax
UUIDTableEntry
Access
Not accessible
Index
uUIDIndex, uUIDchassisIndex
Chassis Information Group
67
UUID Chassis Index
Name
uUIDchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.20.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
UUID Index
Name
uUIDIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.20.1.2
Description
Defines the index of the UUID in a specified chassis.
Syntax
DellObjectRange
Access
Read-only
UUID Type
Name
uUIDType
Object ID
1.3.6.1.4.1.674.10892.1.300.20.1.3
Description
Defines the type of the UUID for this chassis.
Syntax
DellUUIDType
Access
Read-only
UUID Value
68
Name
uUIDValue
Object ID
1.3.6.1.4.1.674.10892.1.300.20.1.4
Description
Defines the value of the UUID for this chassis.
Syntax
OCTET STRING (SIZE(16))
Access
Read-only
Chassis Information Group
POST Log Table
This section defines attributes for the power-on self-test (POST) log. When you turn on your computer,
the POST checks various system components before the operating system loads. The POST tests the
random-access memory (RAM), the hard drives, and the keyboard, for example. While the POST is
running, it makes a log file that system administrators can view. The variables in this section also
contribute to managing the POST log.
Name
postLogTable
Object ID
1.3.6.1.4.1.674.10892.1.300.30
Description
Defines the POST Log Table.
Syntax
SEQUENCE OF PostLogTableEntry
Access
Not accessible
POST Log Table Entry
Name
postLogTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.300.30.1
Description
Defines the POST Log Table entry.
Syntax
PostLogTableEntry
Access
Not accessible
Index
postLogchassisIndex, postLogRecordIndex
POST Log Chassis Index
Name
postLogchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.30.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
POST Log Record Index
Name
postLogRecordIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.30.1.2
Description
Defines the record number (one-based) of the POST log.
Syntax
DellUnsigned32BitRange
Access
Read-only
Chassis Information Group
69
POST Log State Capabilities Unique
Name
postLogStateCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.30.1.3
Description
Defines the capabilities of the object that is writing the POST log.
Syntax
DellStateCapabilitiesLogUnique
Access
Read-only
POST Log State Settings Unique
Name
postLogStateSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.30.1.4
Description
Defines the state of the object that is writing the POST log.
Syntax
DellStateSettingsLogUnique
Access
Read-write
POST Log Record
Name
postLogRecord
Object ID
1.3.6.1.4.1.674.10892.1.300.30.1.5
Description
Defines the data for the specified chassis and record index in the POST log
being returned.
Syntax
DisplayString (SIZE (0..1024))
Access
Read-only
POST Log Format
70
Name
postLogFormat
Object ID
1.3.6.1.4.1.674.10892.1.300.30.1.5
Description
Defines format of the POST log.
Syntax
DellLogFormat (See Table 5-1.)
Access
Read-only
Chassis Information Group
Event Log Table
Name
eventLogTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.300.40
Description
Defines the Event Log Table.
Syntax
SEQUENCE OF EventLogTableEntry
Access
Not accessible
Event Log Table Entry
Name
eventLogTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.300.40.1
Description
Defines the event Log Table Entry.
Syntax
EventLogTableEntry
Access
Not accessible
Index
eventLogchassisIndex,eventLogRecordIndex
Event Log Chassis Index
Name
eventLogchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.40.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Event Log Record Index
Name
eventLogRecordIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.40.1.2
Description
Defines the record index of the event log.
Syntax
DellUnsigned32BitRange
Access
Read-only
Chassis Information Group
71
Event Log State Capabilities Unique
Name
eventLogStateCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.40.1.3
Description
Defines the capabilities of the object that is writing the event log.
Syntax
DellStateCapabilitiesLogUnique
Access
Read-only
Event Log State Settings Unique
Name
eventLogStateSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.300.40.1.4
Description
Defines the state settings for the object that is writing the event log.
Syntax
DellStateSettingsLogUnique
Access
Read-write
Event Log Record
Name
eventLogRecord
Object ID
1.3.6.1.4.1.674.10892.1.300.40.1.5
Description
Defines the data for the specified chassis and log record index in the
event log being returned.
Syntax
DisplayString (SIZE (0..1024))
Access
Read-only
Event Log Format
72
Name
eventLogFormat
Object ID
1.3.6.1.4.1.674.10892.1.300.40.1.6
Description
Defines the format of the event log.
Syntax
DellLogFormat (See Table 5-1.)
Access
Read-only
Chassis Information Group
Event Log Severity Status
Name
eventLogSeverityStatus
Object ID
1.3.6.1.4.1.674.10892.1.300.40.1.7
Description
Defines the severity of the event log record.
Syntax
DellStatus
Access
Read-only
Status
Mandatory
Event Log Date Name
Name
eventLogDateName
Object ID
1.3.6.1.4.1.674.10892.1.300.40.1.8
Description
Defines the date and time of the event log record.
Syntax
DellDateName
Access
Read-only
Status
Mandatory
System BIOS Table
This table lists objects that define the system’s basic input/output system (BIOS).
Name
systemBIOSTable
Object ID
1.3.6.1.4.1.674.10892.1.300.50
Description
Defines the System BIOS Table.
Syntax
SEQUENCE OF SystemBIOSTableEntry
Access
Not accessible
System BIOS Table Entry
Name
systemBIOSTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1
Description
Defines the System BIOS Table entry.
Syntax
SystemBIOSTableEntry
Access
Not accessible
Index
systemBIOSchassisIndex,systemBIOSIndex
Chassis Information Group
73
System BIOS Chassis Index
Name
systemBIOSchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
System BIOS Index
Name
systemBIOSIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.2
Description
Defines the index (one-based) of the system BIOS of this object.
Syntax
DellObjectRange
Access
Read-only
System BIOS State Capabilities
Name
systemBIOSStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.3
Description
Defines the capabilities of the system BIOS of this object.
Syntax
DellStateCapabilities
Access
Read-only
System BIOS State Settings
74
Name
systemBIOSStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.4
Description
Defines the state of the system BIOS of this object.
Syntax
DellStateSettings
Access
Read-write
Chassis Information Group
System BIOS Status
Name
systemBIOSStatus
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.5
Description
Defines the status of the system BIOS of this object.
Syntax
DellStatus
Access
Read-only
System BIOS Size
Name
systemBIOSSize
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.6
Description
Defines the image size of the system BIOS in kilobytes (KB). A zero (0)
indicates that the image size of the BIOS is unknown.
Syntax
DellUnsigned32BitRange
Access
Read-only
System BIOS Release Date Name
Name
systemBIOSReleaseDateName
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.7
Description
Defines the release date of the system BIOS.
Syntax
DellDateName
Access
Read-only
System BIOS Version Name
Name
systemBIOSVersionName
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.8
Description
Defines the version name of the system BIOS.
Syntax
DellString
Access
Read-only
Chassis Information Group
75
System BIOS Starting Address
Name
systemBIOSStartingAddress
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.9
Description
Defines the starting address of the system BIOS. A zero (0) indicates that
the address is unknown.
Syntax
DellUnsigned64BitRange
Access
Read-only
System BIOS Ending Address
Name
systemBIOSEndingAddress
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.10
Description
Defines the ending address of the system BIOS. A zero (0) indicates that
the address is unknown.
Syntax
DellUnsigned64BitRange
Access
Read-only
System BIOS Manufacturer Name
76
Name
systemBIOSManufacturerName
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.11
Description
Defines the system BIOS manufacturer’s name.
Syntax
DellString
Access
Read-only
Chassis Information Group
System BIOS Characteristics
Name
systemBIOSCharacteristics
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.12
Description
Defines characteristics of the system BIOS. This attribute is a bit field
where a bit has the meaning defined below when set to 1 (one). Bit 63 is the
first bit in the value, and bit 0 is the last bit in the value. See the description
of DellUnsigned64BitRange at the beginning of this file for more
information on the format of the value.
Bits 48-63 need to be examined in the context of the system ID. The system
ID is available in the attribute chassisID. If the value for chassisID is
non-zero, bits 48-63 have the meaning defined below:
Bit Position Meaning if Set
-------------- -----------------Bit 0
Reserved
Bit 1
Reserved
Bit 2
Unknown
Bit 3
BIOS Characteristics Not Supported
Bit 4
ISA is supported
Bit 5
MCA is supported
Bit 6
EISA is supported
Bit 7
PCI is supported
Bit 8
PC Card (PCMCIA) is supported
Bit 9
Plug and Play is supported
Bit 10
APM is supported
Bit 11
BIOS is Upgradeable (Flash)
Bit 12
BIOS shadowing is allowed
Bit 13
VL-VESA is supported
Bit 14
ESCD support is available
Bit 15
Boot from CD is supported
Bit 16
Selectable Boot is supported
Bit 17
BIOS ROM is socketed
Bit 18
Boot From PC Card (PCMCIA) is supported
Bit 19
EDD (Enhanced Disk Drive) Specification is supported
Bit 20
Int 13h - Japanese Floppy for NEC 9800 1.2mb (3.5 in,
1k Bytes/Sector, 360 RPM) is supported
Bit 21
Int 13h - Japanese Floppy for Toshiba 1.2mb (3.5 in,
360 RPM) is supported
Bit 22
Int 13h - 5.25 in / 360 KB Floppy Services are supported
Bit 23
Int 13h - 5.25 in /1.2MB Floppy Services are supported
Bit 24
Int 13h - 3.5 in / 720 KB Floppy Services are supported
Bit 25
Int 13h - 3.5 in / 2.88 MB Floppy Services are supported
Bit 26
Int 5h, Print Screen Service is supported
Bit 27
Int 9h, 8042 Keyboard services are supported
Bit 28
Int 14h, Serial Services are supported
Chassis Information Group
77
Name
systemBIOSCharacteristics
Description
Bit Position Meaning if Set
-------------- -----------------Bit 29
Bit 30
Bit 31
Bit 32-47
Bit 48
Bit 49
Bit 50
Bit 51
Bit 52
Bit 53-63
Syntax
Int 17h, Printer Services are supported
Int 10h, CGA/Mono Video Services are supported
NEC PC-98
Reserved
Built-in NIC supports Magic Packet
System supports Wake-on-LAN
System supports chassis intrusion
Built-in NIC supports pattern-matching
System BIOS supports a 7-character service tag
Reserved
DellUnsigned64BitRange
System BIOS Characteristics Ext 1
Name
systemBIOSCharacteristicsExt1
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.13
Description
Defines additional characteristics of the system basic input/output system
(BIOS). This attribute is a bit field where a bit has the meaning defined
below when set to 1 (one).
Bit Position Meaning if Set
-------------- -----------------Bit 0
ACPI supported
Bit 1
USB Legacy is supported
Bit 2
AGP is supported
Bit 3
I2O boot is supported
Bit 4
LS-120 boot is supported
Bit 5
ATAPI ZIP Drive boot is supported
Bit 6
1394 boot is supported
Bit 7
Smart Battery supported
78
Syntax
DellUnsigned8BitRange
Access
Read-only
Chassis Information Group
System BIOS Characteristics Ext 2
Name
systemBIOSCharacteristicsExt2
Object ID
1.3.6.1.4.1.674.10892.1.300.50.1.14
Description
Defines additional characteristics of the system BIOS. This attribute is a bit
field where a bit has the meaning defined below when set to 1 (one).
Bit Position Meaning if Set
--------------- -------------------Bit 0
BIOS Boot Specification supported
Bit 1
Function key-initiated Network Service boot supported
Bit 2
Targeted Content Distribution supported
Bit 3-7
Reserved
Syntax
DellUnsigned8BitRange
Access
Read-only
Firmware Table
Name
firmwareTable
Object ID
1.3.6.1.4.1.674.10892.1.300.60
Description
Defines the Firmware Table.
Syntax
SEQUENCE OF FirmwareTableEntry
Access
Not accessible
Firmware Table Entry
Name
firmwareTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.300.60.1
Description
Defines the Firmware Table entry.
Syntax
FirmwareTableEntry
Access
Not accessible
Index
firmwarechassisIndex, firmwareIndex
Chassis Information Group
79
Firmware Chassis Index
Name
firmwarechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.60.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Firmware Index
Name
firmwareIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.60.1.2
Description
Defines the index (one-based) of the firmware in this chassis.
Syntax
DellObjectRange
Access
Read-only
Firmware State Capabilities
Name
firmwareStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.300.60.1.3
Description
Defines the capabilities of the firmware states.
Syntax
DellStateCapabilities
Access
Read-only
Firmware State Capabilities
80
Name
firmwareStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.300.60.1.4
Description
Defines the state of the firmware and allows for the setting of the firmware.
Syntax
DellStateSettings
Access
Read-write
Chassis Information Group
Firmware Status
Name
firmwareStatus
Object ID
1.3.6.1.4.1.674.10892.1.300.60.1.5
Description
Defines the status of the firmware.
Syntax
DellStateSettings
Access
Read-only
Firmware Size
Name
firmwareSize
Object ID
1.3.6.1.4.1.674.10892.1.300.60.1.6
Description
Defines the image size of the firmware in KB. A zero (0) indicates that the
size is unknown.
Syntax
DellUnsigned16BitRange
Access
Read-only
Firmware Type
Name
firmwareType
Object ID
1.3.6.1.4.1.674.10892.1.300.60.1.7
Description
Defines the type of the firmware.
Syntax
DellFirmwareType
Access
Read-only
Firmware Type Name
Name
firmwareTypeName
Object ID
1.3.6.1.4.1.674.10892.1.300.60.1.8
Description
Defines the name of firmware type.
Syntax
DellString
Access
Read-only
Chassis Information Group
81
Firmware Update Capabilities
Name
firmwareUpdateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.300.60.1.9
Description
Defines the bitmap of supported methods for firmware update.
Syntax
DellUnsigned16BitRange
Access
Read-only
Firmware Date Name
Name
firmwareDateName
Object ID
1.3.6.1.4.1.674.10892.1.300.60.1.10
Description
Defines the date of the firmware.
Syntax
DellDateName
Access
Read-only
Firmware Version Name
Name
firmwareVersionName
Object ID
1.3.6.1.4.1.674.10892.1.300.60.1.11
Description
Defines the version name of the firmware.
Syntax
DellString
Access
Read-only
Intrusion Table
The following objects and attributes describe the different forms of chassis intrusion, a situation that
occurs when the cover of a computer is removed.
82
Name
intrusionTable
Object ID
1.3.6.1.4.1.674.10892.1.300.70
Description
Defines the Intrusion Table.
Syntax
SEQUENCE OF IntrusionTableEntry
Access
Not accessible
Chassis Information Group
Intrusion Table Entry
Name
intrusionTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.300.70.1
Description
Defines the Intrusion Table entry.
Syntax
IntrusionTableEntry
Access
Not accessible
Index
intrusionchassisIndex, intrusionIndex
Intrusion Chassis Index
Name
intrusionchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.70.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Intrusion Index
Name
intrusionIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.70.1.2
Description
Defines the index of the intrusion objects in this subgroup.
Syntax
DellObjectRange
Access
Read-only
Intrusion State Capabilities
Name
intrusionStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.300.70.1.3
Description
Defines the capabilities of the intrusion object.
Syntax
DellStateCapabilities
Access
Read-only
Chassis Information Group
83
Intrusion State Settings
Name
intrusionStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.300.70.1.4
Description
Defines the settings of the intrusion object.
Syntax
DellStateSettings
Access
Read-write
Intrusion Status
Name
intrusionStatus
Object ID
1.3.6.1.4.1.674.10892.1.300.70.1.5
Description
Defines the status of the intrusion object.
Syntax
DellStatus
Access
Read-only
Intrusion Reading
Name
intrusionReading
Object ID
1.3.6.1.4.1.674.10892.1.300.70.1.6
Description
Defines the reading of the intrusion object.
Syntax
DellIntrusionReading
Access
Read-only
Intrusion Type
84
Name
intrusionType
Object ID
1.3.6.1.4.1.674.10892.1.300.70.1.7
Description
Defines the type of the intrusion object.
Syntax
DellIntrusionType
Access
Read-only
Chassis Information Group
Intrusion Location Name
Name
intrusionLocationName
Object ID
1.3.6.1.4.1.674.10892.1.300.70.1.8
Description
Defines the location name of the intrusion object in this subgroup.
Syntax
DellString
Access
Read-only
Baseboard Table
This table lists objects that define the baseboard of a system.
Name
baseBoardTable
Object ID
1.3.6.1.4.1.674.10892.1.300.80
Description
Defines the Baseboard Table.
Syntax
SEQUENCE OF BaseBoardTableEntry
Access
Not accessible
Baseboard Table Entry
Name
baseBoardTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1
Description
Defines the Baseboard Table entry.
Syntax
BaseBoardTableEntry
Access
Not accessible
Index
baseBoardChassisIndex, baseBoardIndex
Baseboard Chassis Index
Name
baseBoardChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.1
Description
Defines the index (one-based) of the associated chassis.
Syntax
DellObjectRange
Access
Read-only
Chassis Information Group
85
Baseboard Index
Name
baseBoardIndex
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.2
Description
Defines the index (one-based) of the base board.
Syntax
DellObjectRange
Access
Read-only
Baseboard State Capabilities
Name
baseBoardStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.3
Description
Defines the state capabilities of the baseboard.
Syntax
DellStateCapabilities
Access
Read-only
Baseboard State Settings
Name
baseBoardStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.4
Description
Defines the state settings of the baseboard.
Syntax
DellStateSettings
Access
Read-write
Baseboard Status
86
Name
baseBoardStatus
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.5
Description
Defines the status of the baseboard.
Syntax
DellStatus
Access
Read-only
Chassis Information Group
Baseboard Feature Flags
Name
baseBoardFeatureFlags
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.6
Description
Defines the features of the baseboard.
Syntax
DellBaseBoardFeatureFlags
Access
Read-only
Baseboard Type
Name
baseBoardType
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.7
Description
Defines the type of the baseboard.
Syntax
DellBaseBoardType
Access
Read-only
Baseboard Type Name
Name
baseBoardTypeName
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.8
Description
Defines the name of the type of baseboard.
Syntax
DellString
Access
Read-only
Baseboard Location Name
Name
baseBoardLocationName
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.9
Description
Defines the location name of the baseboard.
Syntax
DellString
Access
Read-only
Chassis Information Group
87
Baseboard Manufacturer Name
Name
baseBoardManufacturerName
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.10
Description
Defines the baseboard manufacturer’s name.
Syntax
DellString
Access
Read-only
Baseboard Product Name
Name
baseBoardProductName
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.11
Description
Defines the baseboard product’s name.
Syntax
DellString
Access
Read-only
Baseboard Version Name
Name
baseBoardVersionName
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.12
Description
Defines the baseboard version name.
Syntax
DellString
Access
Read-only
Baseboard Service Tag Name
88
Name
baseBoardServiceTagName
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.13
Description
Defines the baseboard service tag name.
Syntax
DellString
Access
Read-only
Chassis Information Group
Baseboard Piece Part ID (PPID) Name
Name
baseBoardPiecePartIDName
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.14
Description
Defines the baseboard PPID.
Syntax
DellString
Access
Read-only
Baseboard Asset Tag Name
Name
baseBoardAssetTagName
Object ID
1.3.6.1.4.1.674.10892.1.300.80.1.15
Description
Defines the baseboard asset tag name.
Syntax
DellString
Access
Read-only
Chassis Information Group Variable Values
This section includes definitions for server administrator-specific variable values used in this section.
Table 5-1.
Log Format
Variable Name: DellLogFormat
Data Type: Integer
Possible Data Values
Meaning of Data Value
raw(1)
The log is in the format received from the firmware.
ascii(2)
The log is in ASCII format.
uniCode(3)
The log is in Unicode format.
Chassis Information Group
89
Table 5-2.
Chassis Type
Variable Name: DellChassisType
Data Type: Integer
90
Possible Data Values
Meaning of Data Value
other(1)
The chassis type is not one of the following:
unknown(2)
The chassis type is unknown.
desktop(3)
The chassis type is a desktop.
lowProfileDesktop(4)
The chassis type is a low-profile desktop.
pizzaBox(5)
The chassis type is a pizza box.
miniTower(6)
The chassis type is a minitower.
tower(7)
The chassis type is a tower.
portable(8)
The chassis type is a portable.
lapTop(9)
The chassis type is a laptop.
noteBook(10)
The chassis type is a notebook.
handHeld(11)
The chassis type is a handheld.
dockingStation(12)
The chassis type is a docking station.
allInOne(13)
The chassis type is an all-in-one.
subNoteBook(14)
The chassis type is a subnotebook.
spaceSaving(15)
The chassis type is a spacesaver.
lunchBox(16)
The chassis type is a lunch box.
mainSystemChassis(17)
The chassis type is the main system chassis.
expansionChassis(18)
The chassis type is an expansion chassis.
subChassis(19)
The chassis type is a subchassis.
busExpansionChassis(20)
The chassis type is a bus-expansion chassis.
peripheralChassis(21)
The chassis type is a peripheral chassis.
raidChassis(22)
The chassis type is a disk RAID chassis.
rackMountChassis(23)
The chassis type is a rack-mounted chassis.
sealedCasePC(24)
The chassis type is a sealed-case chassis.
multiSystemChassis(25)
The chassis type is a multisystem chassis.
Chassis Information Group
Table 5-3.
Connection Status
Variable Name: DellConnectionStatus
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(2)
The status of the chassis connection is unknown.
ok(3)
The status of the chassis connection is OK.
failure(4)
The status of the chassis connection is failure.
Table 5-4.
Fan Control Capabilities
Variable Name: DellFanControlCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
The fan’s capabilities are unknown.
lowSpeedCapable(2)
The fan can be set to low speed.
highSpeedCapable(4)
The fan can be set to high speed.
lowOrHighSpeedCapable(6)
The fan can be set to low or high speed.
Table 5-5.
Front-Panel LED Control Capabilities
Variable Name: DellLEDControlCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
The LED control capabilities are unknown.
alertOnErrorCapable(2)
The LED control can be set to alert on an error condition.
alertOnWarningAndErrorCapable(4)
The LED control can be set to alert on an error and a
warning condition.
alertOnWarningOrErrorCapable(6)
The LED control can be set to alert on an error or a
warning condition.
Chassis Information Group
91
Table 5-6.
Front-Panel LED Control Settings
Variable Name: DellLEDControlSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
The LED control setting is unknown.
alertOnError(2)
The LED control is set to alert on an error condition.
alertOnWarningAndError(4)
The LED control is set to alert on an error or a
warning condition.
Table 5-7.
Hard-Drive Fault LED Control Capabilities
Variable Name: DellHDFaultLEDControlCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The hard drive has no fault LED capabilities.
unknownCapabilities(1)
The hard-drive fault LED capabilities are unknown.
enableCapable(2)
The hard-drive fault LED can be disabled (offline, a binary 0
value) or enabled (online, a binary 1 value).
notReadyCapable(4)
The hard-drive fault LED can indicate not ready.
resetCapable(8)
The hard-drive fault LED can be reset.
Table 5-8.
Hard-Drive Fault LED Control Settings
Variable Name: DellHDFaultLEDControlSettings
Data Type: Integer
92
Possible Data Values
Meaning of Data Value
none(0)
The LEDs do not have any fault settings capabilities.
unknown(1)
The hard-drive fault LEDs’ state is unknown.
enabled(2)
The hard-drive fault LEDs’ state is disabled (offline, a binary 0
value) or enabled (online, a binary 1 value).
notReady(4)
The hard-drive fault LEDs’ state is not ready.
reset(8)
The hard-drive fault LEDs have been reset.
resetAndEnable(10)
The hard-drive fault LEDs have been reset and enabled.
Chassis Information Group
Table 5-9.
Chassis Identification Control Capabilities
Variable Name: DellChassisIdentifyControlCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The LEDs do not have any chassis identification capabilities.
unknownCapabilities(1)
The chassis identification control’s capabilities are unknown.
enableCapable(2)
The chassis identification controls can be disabled (offline, a
binary 0 value) or enabled (online, a binary 1 value).
notReadyCapable(4)
The chassis identification control’s capabilities are not ready.
identifyCapable(8)
The chassis identification control’s LEDs can be made to
identify the chassis.
NOTE: Chassis identification capabilities allow system administrators to set front panel light-emitting diodes (LEDs)
to blink when the chassis has malfunctioning components. When enabled, the blinking lights help administrators
locate the problem chassis.
Table 5-10.
Chassis Identification Control Settings
Variable Name: DellChassisIdentifyControlSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
The chassis identification control’s state is unknown.
enabled(2)
The chassis identification control’s state is disabled (offline,
a binary 0 value) or enabled (online, a binary 1 value).
notReady(4)
The chassis identification control’s state is not ready.
identifyChassis(8)
The chassis identification control’s LEDs may be
returned to (normal) 0, or (identify chassis) 1.
identifyChassisAndEnable(10)
The chassis identification control’s LEDs may be
returned to normal (a binary 0 value), or identify
chassis and enabled (a binary 1 value).
Chassis Information Group
93
Table 5-11.
Host Control Capabilities
Variable Name: DellHostControlCapabilities
NOTE: An operator can manually cause these actions using SNMP.
Data Type: Integer
Possible Data Values
Meaning of Data Value
manualRebootCapable(1)
The operator can reboot capable host.
manualPowerOFFCapable(2)
The operator can power off capable host.
manualPowerCycleCapable(4)
The operator can power-cycle capable host.
manualAllExceptOperatingSystemShutdown The operator can reboot and power off capable host.
Capable(7)
manualOperatingSystemShutdownCapable(8) The operator can shut down the operatingsystem–shutdown capable host.
manualFullyCapable(15)
Table 5-12.
The operator can reboot, power on and off the power-cycle
capable host, and shut down the
operating-system–shutdown capable host.
Host Control Settings
Variable Name: DellHostControlSettings
NOTE: An operator can manually cause these actions using SNMP.
Data Type: Integer
Possible Data Values
Meaning of Data Value
manualReboot(1)
The operator can reboot the host.
manualPowerOFF(2)
The operator can power off the host.
manualPowerCycle(4)
Power cycle the host.
manualOperatingSystemShutdown(8)
The operator can shut down the operating system on the
host.
manualOperatingSystemShutdownThenReboot The operator can shut down the operating system on the
(9)
host then reboot.
manualOperatingSystemShutdownThenPowerOFF The operator can shut down the operating system on the
(10)
host then power off machine.
manualOperatingSystemShutdownThenPower The operator can shut down the operating system on the
Cycle(12)
host then power cycle machine.
94
Chassis Information Group
Table 5-13.
Watchdog Control Capabilities
Variable Name: DellWatchDogControlCapabilities
NOTE: When the system determines that the operating system is not responding, it will automatically perform the
selected action without operator intervention.
Data Type: Integer
Possible Data Values
Meaning of Data Value
automaticRebootCapable(1)
Watchdog controls can be set to reboot capable host.
automaticPowerCycleCapable(2)
Watchdog controls can be set to power cycleable
capable host.
automaticNotificationCapable(4)
Watchdog controls can be set to notify capable host.
automaticWatchDogTimerCapable(8)
Watchdog controls can be set to function
automatically.
automaticPowerOffCapable(16)
Watchdog controls can be set to automatically power
off host.
automaticAllExceptNotificationCapable(27) Watchdog controls can be set to automatically
perform all functions except notification capable.
automaticFullyCapable(31)
Table 5-14.
Watchdog controls can be set to automatically
perform all functions.
Watchdog Control Settings
Variable Name: DellWatchControlSettings
NOTE: The watchdog timer is the mechanism used by a chassis to determine if the operating system has
stopped responding.
Data Type: Integer
Possible Data Values
Meaning of Data Value
automaticRebootEnabled(1)
Automatic reboot is enabled for this host.
automaticPowerCycleEnabled(2)
Automatic power cycleable is enabled for this host.
automaticNotificationEnabled(4)
Automatic notification is enabled for this host.
automaticPowerOffEnabled(8)
Automatic power off is enabled for this host.
Chassis Information Group
95
Table 5-15.
Watchdog Timer Capabilities
Variable Name: DellWatchDogTimerCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
type1Capable(1)
Watchdog timer can time in intervals from 20–480 seconds.
type2Capable(2)
Watchdog timer can time in 30-, 60-, 120-, and 480-second intervals.
type3Capable(4)
Watchdog timer can time in 60-second intervals.
Table 5-16.
Power Button Control Capabilities
Variable Name: DellPowerButtonControlCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The power button has no capabilities.
unknownCapabilities(1)
The power button capabilities are unknown.
enableCapable(2)
The power button can be enabled (online) or disabled (offline).
Table 5-17.
Power Button Control Settings
Variable Name: DellPowerButtonControlSettings
Data Type: Integer
96
Possible Data Values
Meaning of Data Value
none(0)
The power button has no settings capabilities.
unknown(1)
The power button settings are unknown.
enabled(2)
The power button state is enabled.
disabled(4)
The power button state is disabled.
Chassis Information Group
Table 5-18.
NMI Button Control Capabilities
Variable Name: DellNMIButtonControlCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The NMI button has no capabilities.
unknownCapabilities(1)
The NMI button capabilities are unknown.
enableCapable(2)
The NMI button can be enabled (online) or disabled (offline).
Table 5-19.
NMI Button Control Settings
Variable Name: DellNMIButtonControlSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The NMI button has no settings capabilities.
unknown(1)
The NMI button settings are unknown.
enabled(2)
The NMI button state is enabled.
disabled(4)
The NMI button state is disabled.
Table 5-20.
Chassis System Class
Variable Name: DellChassisSystemClass
Data Type: Integer
Possible Data Values
Meaning of Data Value
other(1)
The chassis system class is not one of the following:
unknown(2)
The chassis system class is unknown.
workstationClass(3)
The chassis system class is a workstation.
serverClass(4)
The chassis system class is a server.
desktopClass(5)
The chassis system class is a desktop.
portableClass(6)
The chassis system class is a portable.
netPCClass(7)
The chassis system class is a "Net PC."
storageClass(8)
The chassis system class is storage.
Chassis Information Group
97
Table 5-21.
Firmware Type
Variable Name: DellFirmwareType
Data Type: Integer
Possible Data Values
Meaning of Data Value
other(1)
The firmware type is other than following values.
unknown(2)
The firmware type is unknown.
systemBIOS(3)
The firmware type is System BIOS
embeddedSystemManagementController(4) The firmware type is Embedded System Management
Controller.
98
powerSupplyParallelingBoard(5)
The firmware type is Power Supply Paralleling Board.
systemBackPlane(6)
The firmware type is System (Primary) Backplane.
powerVault2XXSKernel(7)
The firmware type is Dell™ PowerVault™ 2XXS Kernel.
powerVault2XXSApplication(8)
The firmware type is PowerVault 2XXS Application.
frontPanel(9)
The firmware type is Front Panel Controller.
baseboardManagementController(10)
The firmware type is Baseboard Management Controller.
hotPlugPCI(11)
The firmware type is Hot Plug Peripheral Component
Interconnect (PCI) Controller.
sensorData(12)
The firmware type is Sensor Data Records.
peripheralBay(13)
The firmware type is Peripheral Bay Backplane.
secondaryBackPlane(14)
The firmware type is Secondary Backplane for
ESM 2 systems.
secondaryBackPlaneESM3And4(15)
The firmware type is Secondary Backplane for ESM 3 and 4
systems.
rac(16)
The firmware type is Remote Access Controller.
Chassis Information Group
Table 5-22.
Baseboard Type
Variable Name: DellBaseBoardType
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
The baseboard type is unknown.
other(2)
The baseboard type is not one of the following types.
serverBlade(3)
The baseboard type is a server blade.
connectivitySwitch(4)
The baseboard type is a connectivity switch.
systemManagementModule(5)
The baseboard type is a system management module.
processorModule(6)
The baseboard type is a processor module.
ioModule(7)
The baseboard type is an I/O module.
memoryModule(8)
The baseboard type is a memory module
daughterBoard(9)
The baseboard type is a daughter board.
motherboard(10)
The baseboard type is a mother board.
processorMemoryModule(11)
The baseboard type is a processor or memory module
processorIOModule(12)
The baseboard type is a processor or I/O module
interconnectBoard(13)
The baseboard type is an interconnect board.
Table 5-23.
Baseboard Feature Flags
Variable Name: DellBaseBoardFeatureFlags
Data Type: Integer
Possible Data Values
Meaning of Data Value
NOTE: These values are bit fields, so combination values are possible.
no features(0)
This baseboard has no feature flags.
boardIsHostingBoard(1)
This baseboard is a hosting board.
boardRequiresDaughterBoard(2)
This baseboard requires at least one daughter board or
auxiliary card.
boardIsRemovable(4)
This baseboard is removable.
boardIsReplaceable(8)
This baseboard is replaceable.
boardIsHotSwappable(16)
This baseboard is hot swappable.
Chassis Information Group
99
100
Chassis Information Group
Operating System Group
The Operating System Group provides status and identifying information about a system’s
operating system. Identifying information includes the name, version, service pack, and patch level
of the installed operating system.
Operating System Group Table
The following management information base (MIB) tables define the objects in the Operating
System Group:
•
Operating System Table
•
Operating System Memory Table
Operating System Table
The following object sets up the Operating System Table.
Name
operatingSystemTable
Object ID
1.3.6.1.4.1.674.10892.1.400.10
Description
Defines the Operating System Table.
Syntax
SEQUENCE OF OperatingSystemTableEntry
Access
Not accessible
Operating System Table Entry
Name
operatingSystemTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.400.10.1
Description
Defines the Operating System Table entry.
Syntax
OperatingSystemTableEntry
Access
Not accessible
Index
operatingSystemchassisIndex
Operating System Group
101
Operating System Chassis Index
Name
operatingSystemchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.400.10.1.1
Description
Defines the index (one based) of the associated chassis.
Syntax
DellObjectRange
Access
Read-only
Operating System State Capabilities
Name
operatingSystemStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.400.10.1.2
Description
Defines the capabilities of the operating system.
Syntax
DellStateCapabilities
Access
Read-only
Operating System State Settings
Name
operatingSystemStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.400.10.1.3
Description
Defines the state of the operating system.
Syntax
DellStateSettings
Access
Read-write
Operating System Status
102
Name
operatingSystemStatus
Object ID
1.3.6.1.4.1.674.10892.1.400.10.1.4
Description
Defines the status of the operating system.
Syntax
DellStatus
Access
Read-only
Operating System Group
Operating System Is Primary
Name
operatingSystemIsPrimary
Object ID
1.3.6.1.4.1.674.10892.1.400.10.1.5
Description
Specifies whether this operating system is the primary operating system.
Syntax
DellBoolean
Access
Read-only
Operating System Name
Name
operatingSystemOperatingSystemName
Object ID
1.3.6.1.4.1.674.10892.1.400.10.1.6
Description
Defines the name of the operating system running on the system.
Syntax
DisplayString (SIZE (0..255))
Access
Read-only
Operating System Version Name
Name
operatingSystemOperatingSystemVersionName
Object ID
1.3.6.1.4.1.674.10892.1.400.10.1.7
Description
Defines the version of the operating system running on the system.
Syntax
DisplayString (SIZE (0..255))
Access
Read-only
Operating System Memory Table
Name
operatingSystemMemoryTable
Object ID
1.3.6.1.4.1.674.10892.1.400.20
Description
Defines the Operating System Memory Table.
Syntax
SEQUENCE OF OperatingSystemMemoryTableEntry
Access
Not accessible
Operating System Group
103
Operating System Memory Table Entry
Name
operatingSystemTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.400.20.1
Description
Defines the Operating System Memory Table entry.
Syntax
OperatingSystemMemoryTableEntry
Access
Not accessible
Index
operatingSystemMemorychassisIndex
Operating System Memory Chassis Index
Name
operatingSystemMemorychassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.400.20.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Operating System Memory State Capabilities
Name
operatingSystemMemoryStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.400.20.1.2
Description
Defines the capabilities of the operating system memory.
Syntax
DellStateCapabilities
Access
Read-only
Operating System Memory State Settings
104
Name
operatingSystemMemoryStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.400.20.1.3
Description
Defines the state and allows the setting of the operating system memory.
Syntax
DellStateSettings
Access
Read-write
Operating System Group
Operating System Memory Status
Name
operatingSystemMemoryStatus
Object ID
1.3.6.1.4.1.674.10892.1.400.20.1.4
Description
Defines the status of the operating system memory.
Syntax
DellStatus
Access
Read-only
Operating System Memory Total Physical Size
Name
operatingSystemMemoryTotalPhysicalSize
Object ID
1.3.6.1.4.1.674.10892.1.400.20.1.5
Description
Defines the total physical memory size in bytes.
Syntax
DellUnsigned32BitRange
Access
Read-only
Operating System Memory Available Physical Size
Name
operatingSystemMemoryAvailablePhysicalSize
Object ID
1.3.6.1.4.1.674.10892.1.400.20.1.6
Description
Defines the available physical memory size in bytes.
Syntax
DellUnsigned32BitRange
Access
Read-only
Operating System Memory Total Page File Size
Name
operatingSystemMemoryTotalPageFileSize
Object ID
1.3.6.1.4.1.674.10892.1.400.20.1.7
Description
Defines the total page file memory size in bytes.
Syntax
DellUnsigned32BitRange
Access
Read-only
Operating System Group
105
Operating System Memory Available Page File Size
Name
operatingSystemMemoryAvailablePageFileSize
Object ID
1.3.6.1.4.1.674.10892.1.400.20.1.8
Description
Defines the available page file memory size in bytes.
Syntax
DellUnsigned32BitRange
Access
Read-only
Operating System Memory Total Virtual Size
Name
operatingSystemMemoryTotalVirtualSize
Object ID
1.3.6.1.4.1.674.10892.1.400.20.1.9
Description
Defines the total virtual memory size in bytes.
Syntax
DellUnsigned32BitRange
Access
Read-only
Operating System Memory Available Virtual Size
106
Name
operatingSystemMemoryAvailableVirtualSize
Object ID
1.3.6.1.4.1.674.10892.1.400.20.1.10
Description
Defines the available virtual memory size in bytes.
Syntax
DellUnsigned32BitRange
Access
Read-only
Operating System Group
System Resource Group
The Management Information Base (MIB) variables presented in this section enable you to track
various attributes of your system resources. This section includes System Resource Group Tables
that track variables such as the owner, ports, system memory, interrupts, and direct memory access.
System Resource Group Tables
The following MIB tables define objects for the System Resource Group:
•
System Resource Map Table
•
System Resource Owner Table
•
System Resource Input/Output (I/O) Port Table
•
System Resource Memory Table
•
System Resource Interrupt Table
•
System Resource Direct Memory Access (DMA) Table
System Resource Map Table
Name
systemResourceMapTable
Object ID
1.3.6.1.4.1.674.10892.1.500.10
Description
Defines the System Resource Map Table.
Syntax
SEQUENCE OF SystemResourceMapTableEntry
Access
Not accessible
System Resource Map Table Entry
Name
systemResourceMapTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.500.10.1
Description
Defines the System Resource Map Table entry.
Syntax
SystemResourceMapTableEntry
Access
Not accessible
Index
systemResourceMapchassisIndex, systemResourceMapIndex
System Resource Group
107
System Resource Map Chassis Index
Name
systemResourceMapChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.500.10.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource Map Index
Name
systemResourceMapIndex
Object ID
1.3.6.1.4.1.674.10892.1.500.10.1.2
Description
Defines the index of system resource maps in this chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource Map State Capabilities
Name
systemResourceMapStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.500.10.1.3
Description
Defines the capabilities of this system map.
Syntax
DellStateCapabilities
Access
Read-only
System Resource Map State Settings
108
Name
systemResourceMapStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.500.10.1.4
Description
Defines the state and allows the setting of this system map.
Syntax
DellStateSettings
Access
Read-write
System Resource Group
System Resource Map Status
Name
systemResourceMapStatus
Object ID
1.3.6.1.4.1.674.10892.1.500.10.1.5
Description
Defines the status of this system map.
Syntax
DellStatus
Access
Read-only
System Resource Map Type
Name
systemResourceMapType
Object ID
1.3.6.1.4.1.674.10892.1.500.10.1.6
Description
Defines the type of this system map.
Syntax
DellSystemResourceMapType (See Table 7-1.)
Access
Read-only
System Resource Owner Table
Name
systemResourceOwnerTable
Object ID
1.3.6.1.4.1.674.10892.1.500.20
Description
Defines the System Resource Owner Table.
Syntax
SEQUENCE OF SystemResourceOwnerTableEntry
Access
Not accessible
System Resource Owner Table Entry
Name
systemResourceOwnerTable
Object ID
1.3.6.1.4.1.674.10892.1.500.20.1
Description
Defines the System Resource Owner Table entry. Variables in this
group reference the System Resource Map index.
Syntax
SystemResourceOwnerTableEntry
Access
Not accessible
Index
systemResourceOwnerchassisIndex, systemResourceOwnerIndex
System Resource Group
109
System Resource Owner Chassis Index
Name
systemResourceOwnerchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.500.20.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource Owner Index
Name
systemResourceOwnerIndex
Object ID
1.3.6.1.4.1.674.10892.1.500.20.1.2
Description
Defines the index of system resource owners for this chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource Owner State Capabilities
Name
systemResourceOwnerStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.500.20.1.3
Description
Defines the capabilities of this system resource owner.
Syntax
DellStateCapabilities
Access
Read-only
System Resource Owner State Settings
110
Name
systemResourceOwnerStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.500.20.1.4
Description
Defines the state settings of this system resource owner.
Syntax
DellStateSettings
Access
Read-write
System Resource Group
System Resource Owner Status
Name
systemResourceOwnerStatus
Object ID
1.3.6.1.4.1.674.10892.1.500.20.1.5
Description
Defines the status of this system resource owner.
Syntax
DellStatus
Access
Read-write
System Resource Owner Interface Type
Name
systemResourceOwnerInterfaceType
Object ID
1.3.6.1.4.1.674.10892.1.500.20.1.6
Description
Defines the interface type for this system resource owner.
Syntax
DellResourceOwnerInterfaceType (See Table 7-2.)
Access
Read-only
System Resource Map Index Reference
Name
systemResourceMapIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.500.20.1.7
Description
Defines the index to the associated system resource map in this
chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource Owner Description Name
Name
systemResourceOwnerDescriptionName
Object ID
1.3.6.1.4.1.674.10892.1.500.20.1.8
Description
Defines the description name of the system resource owner.
Syntax
DellString
Access
Read-only
System Resource Group
111
System Resource Owner Interface Instance
Name
systemResourceOwnerInterfaceInstance
Object ID
1.3.6.1.4.1.674.10892.1.500.20.1.9
Description
Defines the associated system resource owner interface instance in this
chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource Input/Output (I/O) Port Table
Name
systemResourceIOPortTable
Object ID
1.3.6.1.4.1.674.10892.1.500.30
Description
Defines the System Resource I/O Port Table.
Syntax
SEQUENCE OF SystemResourceIOPortTableEntry
Access
Not accessible
System Resource I/O Port Table Entry
Name
systemResourceIOPortTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.500.30.1
Description
Defines the System Resource I/O Port Table entry.
Syntax
SystemResourceIOPortTableEntry
Access
Not accessible
Index
systemResourceIOPortchassisIndex, systemResourceIOPortIndex
System Resource I/O Port Chassis Index
112
Name
systemResourceIOPortchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.500.30.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource Group
System Resource I/O Port Index
Name
systemResourceIOPortIndex
Object ID
1.3.6.1.4.1.674.10892.1.500.30.1.2
Description
Defines the index (one-based) of the system resource I/O ports in this
chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource I/O Port State Capabilities
Name
systemResourceIOPortStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.500.30.1.3
Description
Defines the capabilities of the system resource I/O port.
Syntax
DellStateCapabilities
Access
Read-only
System Resource I/O Port State Settings
Name
systemResourceIOPortStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.500.30.1.4
Description
Defines the state and allows the setting of the system resource I/O port.
Syntax
DellStateSettings
Access
Read-write
System Resource I/O Port Status
Name
systemResourceIOPortStatus
Object ID
1.3.6.1.4.1.674.10892.1.500.30.1.5
Description
Defines the status of the system resource I/O port.
Syntax
DellStateSettings
Access
Read-only
System Resource Group
113
System Resource I/O Port Owner Index Reference
Name
systemResourceIOPortOwnerIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.500.30.1.6
Description
Defines the index to the associated system resource owner in this chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource I/O Port Share Disposition
Name
systemResourceIOPortShareDisposition
Object ID
1.3.6.1.4.1.674.10892.1.500.30.1.7
Description
Defines the share disposition of the system resource I/O port.
Syntax
DellResourceShareDisposition (See Table 7-3.)
Access
Read-only
System Resource I/O Port Starting Address
Name
systemResourceIOPortStartingAddress
Object ID
1.3.6.1.4.1.674.10892.1.500.30.1.8
Description
Defines the 64 bits of the starting address of the system resource I/O port.
Syntax
DellUnsigned64BitRange
Access
Read-only
System Resource I/O Port Ending Address
114
Name
systemResourceIOPortEndingAddress
Object ID
1.3.6.1.4.1.674.10892.1.500.30.1.9
Description
Defines the 64 bits of the ending address of the system resource I/O port.
Syntax
DellUnsigned64BitRange
Access
Read-only
System Resource Group
System Resource Memory Table
Name
systemResourceMemoryTable
Object ID
1.3.6.1.4.1.674.10892.1.500.40
Description
Defines the System Resource Memory Table.
Syntax
SEQUENCE OF SystemResourceMemoryTableEntry
Access
Not accessible
System Resource Memory Table Entry
Name
systemResourceMemoryTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.500.40.1
Description
Defines the System Resource Memory Table entry.
Syntax
SystemResourceMemoryTableEntry
Access
Not accessible
Index
systemResourceMemorychassisIndex,
systemResourceMemoryIndex
System Resource Memory Chassis Index
Name
systemResourceMemorychassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.500.40.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource Memory Index
Name
systemResourceMemoryIndex
Object ID
1.3.6.1.4.1.674.10892.1.500.40.1.2
Description
Defines the index of system resource memory in this chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource Group
115
System Resource Memory State Capabilities
Name
systemResourceMemoryStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.500.40.1.3
Description
Defines the capabilities of this system resource memory.
Syntax
DellObjectRange
Access
Read-only
System Resource Memory State Settings
Name
systemResourceMemoryStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.500.40.1.4
Description
Defines the state of this system resource memory.
Syntax
DellObjectRange
Access
Read-write
System Resource Memory Status
Name
systemResourceMemoryStatus
Object ID
1.3.6.1.4.1.674.10892.1.500.40.1.5
Description
Defines the status of this system resource memory.
Syntax
DellStatus
Access
Read-only
System Resource Memory Owner Index Reference
116
Name
systemResourceMemoryOwnerIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.500.40.1.6
Description
Defines the index to the associated system resource owner in this chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource Group
System Resource Memory Share Disposition
Name
systemResourceMemoryShareDisposition
Object ID
1.3.6.1.4.1.674.10892.1.500.40.1.7
Description
Defines the share disposition of the system resource memory.
Syntax
DellResourceShareDisposition (See Table 7-3.)
Access
Read-only
System Resource Memory Starting Address
Name
systemResourceMemoryStartingAddress
Object ID
1.3.6.1.4.1.674.10892.1.500.40.1.8
Description
Defines the 64 bits of the starting address of the system resource memory.
Syntax
DellUnsigned64BitRange
Access
Read-only
System Resource Memory Ending Address
Name
systemResourceMemoryEndingAddress
Object ID
1.3.6.1.4.1.674.10892.1.500.40.1.9
Description
Defines the 64 bits of the ending address of the system resource memory.
Syntax
DellUnsigned64BitRange
Access
Read-only
System Resource Memory Flags
Name
systemResourceMemoryFlags
Object ID
1.3.6.1.4.1.674.10892.1.500.40.1.10
Description
Defines the permission flags for the system resource memory.
Syntax
DellResourceMemoryFlags (See Table 7-4.)
Access
Read-only
System Resource Group
117
System Resource Interrupt Table
Name
systemResourceInterruptTable
Object ID
1.3.6.1.4.1.674.10892.1.500.50
Description
Defines the System Resource Interrupt Table.
Syntax
SEQUENCE OF SystemResourceInterruptTableEntry
Access
Not accessible
System Resource Interrupt Table Entry
Name
systemResourceInterruptTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.500.50.1
Description
Defines the System Resource Interrupt Table entry.
Syntax
SystemResourceInterruptTableEntry
Access
Not accessible
Index
systemResourceInterruptchassisIndex,
systemResourceInterruptIndex
System Resource Interrupt Chassis Index
Name
systemResourceInterruptchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.500.50.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Not accessible
System Resource Interrupt Index
118
Name
systemResourceInterruptIndex
Object ID
1.3.6.1.4.1.674.10892.1.500.50.1.2
Description
Defines the index (one-based) of this interrupt resource.
Syntax
DellObjectRange
Access
Read-only
System Resource Group
System Resource Interrupt State Capabilities
Name
systemResourceInterruptStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.500.50.1.3
Description
Defines the capabilities of this system resource interrupt.
Syntax
DellStateCapabilities
Access
Read-only
System Resource Interrupt State Settings
Name
systemResourceInterruptStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.500.50.1.4
Description
Defines the state of this system resource interrupt.
Syntax
DellStateSettings
Access
Read-write
System Resource Interrupt Status
Name
systemResourceInterruptStatus
Object ID
1.3.6.1.4.1.674.10892.1.500.50.1.5
Description
Defines the status of this system resource interrupt.
Syntax
DellStatus
Access
Read-only
System Resource Interrupt Owner Index Reference
Name
systemResourceInterruptOwnerIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.500.50.1.6
Description
Defines the index for the associated system resource owner in this chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource Group
119
System Resource Interrupt Owner Share Disposition
Name
systemResourceInterruptShareDisposition
Object ID
1.3.6.1.4.1.674.10892.1.500.50.1.7
Description
Defines the share disposition of the system resource interrupt.
Syntax
DellResourceShareDisposition (See Table 7-3.)
Access
Read-only
System Resource Interrupt Level
Name
systemResourceInterruptLevel
Object ID
1.3.6.1.4.1.674.10892.1.500.50.1.8
Description
Defines the interrupt request (IRQ) level of the system resource interrupt.
Syntax
DellUnsigned32BitRange
Access
Read-only
System Resource Interrupt Type
Name
systemResourceInterruptType
Object ID
1.3.6.1.4.1.674.10892.1.500.50.1.9
Description
Defines the interrupt type of the system resource interrupt.
Syntax
DellResourceInterruptType (See Table 7-5.)
Access
Read-only
System Resource Interrupt Trigger
120
Name
systemResourceInterruptTrigger
Object ID
1.3.6.1.4.1.674.10892.1.500.50.1.10
Description
Defines the interrupt trigger of the system resource interrupt.
Syntax
DellResourceInterruptTrigger (See Table 7-6.)
Access
Read-only
System Resource Group
System Resource Direct Memory Access (DMA) Table
Name
systemResourceDMATable
Object ID
1.3.6.1.4.1.674.10892.1.500.60
Description
Defines the System Resource DMA Table.
Syntax
SEQUENCE OF SystemResourceDMATableEntry
Access
Not accessible
System Resource DMA Table Entry
Name
systemResourceDMATable
Object ID
1.3.6.1.4.1.674.10892.1.500.60.1
Description
Defines the System Resource DMA Table entry.
Syntax
SystemResourceDMATableEntry
Access
Not accessible
Index
systemResourceDMAchassisIndex, systemResourceDMAIndex
System Resource DMA Chassis Index
Name
systemResourceDMAchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.500.60.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource DMA Index
Name
systemResourceDMAIndex
Object ID
1.3.6.1.4.1.674.10892.1.500.60.1.2
Description
Defines the index of system resource DMAs in this chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource Group
121
System Resource DMA State Capabilities
Name
systemResourceDMAStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.500.60.1.3
Description
Defines the capabilities of this system resource DMA.
Syntax
DellStateCapabilities
Access
Read-only
System Resource DMA State Settings
Name
systemResourceDMAStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.500.60.1.4
Description
Defines the state and setting of this system resource DMA.
Syntax
DellStateSettings
Access
Read-write
System Resource DMA Status
Name
systemResourceDMAStatus
Object ID
1.3.6.1.4.1.674.10892.1.500.60.1.5
Description
Defines the status of this system resource DMA.
Syntax
DellStatus
Access
Read-only
System Resource DMA Owner Index Reference
122
Name
systemResourceDMAOwnerIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.500.60.1.6
Description
Defines the index to the associated system resource owner in this chassis.
Syntax
DellObjectRange
Access
Read-only
System Resource Group
System Resource DMA Share Disposition
Name
systemResourceDMAShareDisposition
Object ID
1.3.6.1.4.1.674.10892.1.500.60.1.7
Description
Defines the share disposition of the system resource DMA.
Syntax
DellResourceShareDisposition (See Table 7-3.)
Access
Read-only
System Resource DMA Maximum Transfer Size
Name
systemResourceDMAMaximumTransferSize
Object ID
1.3.6.1.4.1.674.10892.1.500.60.1.8
Description
Defines the maximum size of a memory transfer in bytes for the
system resource DMA.
Syntax
DellUnsigned32BitRange
Access
Read-only
System Resource DMA Transfer Width
Name
systemResourceDMATransferWidth
Object ID
1.3.6.1.4.1.674.10892.1.500.60.1.9
Description
Defines the transfer width of the system resource DMA.
Syntax
DellResourceDMATransferWidth (See Table 7-8.)
Access
Read-only
System Resource DMA Bus Master
Name
systemResourceDMABusMaster
Object ID
1.3.6.1.4.1.674.10892.1.500.60.1.10
Description
Defines the bus mastering capabilities of the system resource DMA.
Syntax
DellResourceDMABusMaster (See Table 7-7.)
Access
Read-only
System Resource Group
123
System Resource Group Variable Values
This section includes definitions for server administrator-specific variable values used in this section.
Table 7-1.
System Resource Map Type
Variable Name: DellSystemResourceMapType
Data Type: Integer
Possible Data Values
Meaning of Data Value
other(1)
The system resource map type is not one of the following:
unknown(2)
The system resource map type is unknown (not known or not monitored).
typeOne(3)
The system resource map is type 1 (one).
Table 7-2.
Resource Owner Interface Type
Variable Name: DellResourceOwnerInterfaceType
Data Type: Integer
124
Possible Data Values
Meaning of Data Value
typeIsOther(1)
The interface type is not one of the following:
typeIsUnknown(2)
The interface type is unknown.
typeIsInternal(3)
The interface type is internal.
typeIsISA(4)
The interface type is an Industry Standard Architecture (ISA) bus.
typeIsEISA(5)
The interface type is an Extended Industry Standard Architecture (EISA) bus.
typeIsMCA(6)
The interface type is a microchannel architecture (MCA) bus.
typeIsTurboChannel(7)
The interface type is a turbo-channel bus.
System Resource Group
Table 7-3.
Resource Share Disposition
Variable Name: DellResourceShareDisposition
Data Type: Integer
Possible Data Values
Meaning of Data Value
shareIsOther(1)
The share disposition is not one of the following:
shareIsUnknown(2)
The share disposition is unknown (not known or not monitored).
shareIsDeviceExclusive(3)
The share disposition is device exclusive.
shareIsDriverExclusive(4)
The share disposition is driver exclusive.
shareIsShared(5)
The share disposition is shared.
Table 7-4.
Resource Memory Flags
Variable Name: DellResourceMemoryFlags
Data Type: Integer
Possible Data Values
Meaning of Data Value
memoryIsReadOnly(1)
The resource memory is read-only.
memoryIsWriteOnly(2)
The resource memory is write-only.
memoryIsPreFetchable(4)
The resource memory is prefetchable.
memoryIsCombinedWritable(8)
The resource memory is read-write.
memoryIsF24(16)
The resource memory is F24.
Table 7-5.
Resource Interrupt Type
Variable Name: DellResourceInterruptType
Data Type: Integer
Possible Data Values
Meaning of Data Value
interruptIsLevelSensitive(1)
The interrupt type is level sensitive.
interruptIsLatched(2)
The interrupt type is latched.
System Resource Group
125
Table 7-6.
Resource Interrupt Trigger
Variable Name: DellResourceInterruptTrigger
Data Type: Integer
Possible Data Values
Meaning of Data Value
interruptIsActiveWhenLow(1)
The interrupt trigger is active on a low signal.
interruptIsActiveWhenHigh(2)
The interrupt trigger is active on a high signal.
Table 7-7.
Resource DMA Bus Master
Variable Name: DellResourceDMABusMaster
Data Type: Integer
Possible Data Values
Meaning of Data Value
dmaIsOther(1)
The DMA bus master capability is not one of the following:
dmaIsUnknown(2)
The DMA bus master capability is unknown.
dmaIsNotABusmaster(3)
The DMA does not have bus master capability.
Table 7-8.
Resource DMA Transfer Width
Variable Name: DellResourceDMATransferWidth
Data Type: Integer
126
Possible Data Values
Meaning of Data Value
dmaTransferWidthIsOther(1)
The DMA transfer width is not one of the following:
dmaTransferWidthIsunknown(2)
The DMA transfer width is unknown.
dmaTransferWidthIs8Bits(3)
The DMA transfer width is 8 bits.
dmaTransferWidthIs16Bits(4)
The DMA transfer width is 16 bits.
dmaTransferWidthIs32Bits(5)
The DMA transfer width is 32 bits.
dmaTransferWidthIs64Bits(6)
The DMA transfer width is 64 bits.
dmaTransferWidthIs128Bits(7)
The DMA transfer width is 128 bits.
System Resource Group
Power Group
The Power Group provides information about power units (a group of power supplies in a system chassis),
power supplies, and voltage and amperage probes.
Power Group Tables
The following management information base (MIB) tables define objects for the Power Group:
•
Power Unit Table
•
Power Supply Table
•
Voltage Probe Table
•
Amperage Probe Table
•
AC Power Switch Table
•
AC Power Cord Table
•
Battery Table
Power Unit Table
Name
powerUnitTable
Object ID
1.3.6.1.4.1.674.10892.1.600.10
Description
Defines the Power Unit Table.
Syntax
PowerUnitTableEntry
Access
Not accessible
Power Unit Table Entry
Name
powerUnitTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.600.10.1
Description
Defines the Power Unit Table entry.
Syntax
DellObjectRange
Access
Read-only
Index
powerUnitchassisIndex, powerUnitIndex
Power Group
127
Power Unit Chassis Index
Name
powerUnitchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.10.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Power Unit Index
Name
powerUnitIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.10.1.2
Description
Defines the index of the power unit in this chassis.
Syntax
DellObjectRange
Access
Read-only
Power Unit State Capabilities
Name
powerUnitStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.600.10.1.3
Description
Defines the capabilities of the power unit.
Syntax
DellStateCapabilities
Access
Read-only
Power Unit State Settings
128
Name
powerUnitStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.600.10.1.4
Description
Defines the state and settings of the power unit.
Syntax
DellStateSettings
Access
Read-write
Power Group
Power Unit Redundancy Status
Name
powerUnitRedundancyStatus
Object ID
1.3.6.1.4.1.674.10892.1.600.10.1.5
Description
Defines the redundancy status of the power unit.
Syntax
DellStatusRedundancy
Access
Read-only
Power Supply Count for Redundancy
Name
powerSupplyCountForRedundancy
Object ID
1.3.6.1.4.1.674.10892.1.600.10.1.6
Description
Defines the total number of power supplies required for this
power unit to have redundancy.
Syntax
DellString
Access
Read-only
Power Unit Name
Name
powerUnitName
Object ID
1.3.6.1.4.1.674.10892.1.600.10.1.7
Description
Defines the name of the power unit in this chassis.
Syntax
DellString
Access
Read-only
Power Unit Status
Name
powerUnitStatus
Object ID
1.3.6.1.4.1.674.10892.1.600.10.1.8
Description
Defines the status of the power unit in this chassis.
Syntax
DellStatus
Access
Read-only
Power Group
129
Power Supply Table
Name
powerSupplyTable
Object ID
1.3.6.1.4.1.674.10892.1.600.12
Description
Defines the Power Supply Table.
Syntax
PowerSupplyTableEntry
Access
Not accessible
Power Supply Table Entry
Name
powerSupplyTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1
Description
Defines the Power Supply Table entry.
Syntax
PowerSupplyTableEntry
Access
Not accessible
Index
powerSupplychassisIndex, powerSupplyIndex
Power Supply Chassis Index
Name
powerSupplychassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Power Supply Index
130
Name
powerSupplyIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1.2
Description
Defines the index of power supply.
Syntax
DellObjectRange
Access
Read-only
Power Group
Power Supply State Capabilities Unique
Name
powerSupplyStateCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1.3
Description
Defines the capabilities of the power supply.
Syntax
DellPowerSupplyStateCapabilitiesUnique (See Table 8-1.)
Access
Read-only
Power Supply State Settings Unique
Name
powerSupplyStateSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1.4
Description
Defines the state and settings of the power supply.
Syntax
DellPowerSupplyStateSettingsUnique (See Table 8-2.)
Access
Read-write
Power Supply Status
Name
powerSupplyStatus
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1.5
Description
Defines the status of the power supply.
Syntax
DellStatus
Access
Read-only
Power Supply Output Watts
Name
powerSupplyOutputWatts
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1.6
Description
Defines the maximum sustained output wattage of the power
supply in tenths of watts.
Syntax
DellSigned32BitRange
Access
Read-only
Power Group
131
Power Supply Type
Name
powerSupplyType
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1.7
Description
Defines the type of power supply.
Syntax
DellPowerSupplyType (See Table 8-3.)
Access
Read-only
Power Supply Location Name
Name
powerSupplyLocationName
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1.8
Description
Defines the location name of the power supply.
Syntax
DellString
Access
Read-only
Power Supply Input Voltage
Name
powerSupplyInputVoltage
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1.9
Description
Defines the input voltage to the power supply in volts.
Syntax
DellSigned32BitRange
Access
Read-only
Power Supply Power Unit Index Reference
132
Name
powerSupplypowerUnitIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1.10
Description
Defines the index to the associated system power unit in this chassis.
Syntax
DellObjectRange
Access
Read-only
Power Group
Power Supply Sensor State
Name
powerSupplySensorState
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1.11
Description
Defines the state reported by the power supply sensor, and
supplements the state and settings of the power supply.
Syntax
DellPowerSupplySensorState (See Table 8-4)
Access
Read-only
Power Supply Configuration Error Type
Name
powerSupplyConfigurationErrorType
Object ID
1.3.6.1.4.1.674.10892.1.600.12.1.12
Description
Defines the type of configuration error reported by the power
supply sensor.
Syntax
DellPowerSupplyConfigurationErrorType (See Table 8-5)
Access
Read-only
Voltage Probe Table
Name
voltageProbeTable
Object ID
1.3.6.1.4.1.674.10892.1.600.20
Description
Defines the Voltage Probe Table.
Syntax
VoltageProbeTableEntry
Access
Not accessible
Voltage Probe Table Entry
Name
voltageProbeTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1
Description
Defines the Voltage Probe Table entry.
Syntax
VoltageProbeTableEntry
Access
Not accessible
Index
voltageProbechassisIndex, voltageProbeIndex
Power Group
133
Voltage Probe Chassis Index
Name
voltageProbechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Voltage Probe Index
Name
voltageProbeIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.2
Description
Defines the index of voltage probes in this chassis.
Syntax
DellObjectRange
Access
Read-only
Voltage Probe State Capabilities
Name
voltageProbeStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.3
Description
Defines the capabilities of the voltage probe.
Syntax
DellStateCapabilities
Access
Read-only
Voltage Probe State Settings
134
Name
voltageProbeStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.4
Description
Defines the state and settings of the voltage probe.
Syntax
DellStateSettings
Access
Read-write
Power Group
Voltage Probe Status
Name
voltageProbeStatus
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.5
Description
Defines the status of the voltage probe.
Syntax
DellStatusProbe
Access
Read-only
Voltage Probe Reading
Name
voltageProbeReading
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.6
Description
Defines the value of the voltage probe reading. The value is an
integer representing the voltage in millivolts that the probe
is reading.
When the value for voltageProbeType is
voltageProbeTypeIsDiscrete, a value is not returned for
this attribute.
Syntax
DellSigned32BitRange
Access
Read-only
Voltage Probe Type
Name
voltageProbeType
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.7
Description
Defines the type of the voltage probe.
Syntax
DellVoltageType
Access
Read-only
Voltage Probe Location Name
Name
voltageProbeLocationName
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.8
Description
Defines the location of the voltage probe in this chassis.
Syntax
DellString
Access
Read-only
Power Group
135
Voltage Probe Upper Nonrecoverable Threshold
Name
voltageProbeUpperNonRecoverableThreshold
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.9
Description
Defines the value of the voltage probe’s upper nonrecoverable
threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Voltage Probe Upper Critical Threshold
Name
voltageProbeUpperCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.10
Description
Defines the value of the voltage probe’s upper critical threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Voltage Probe Upper Noncritical Threshold
Name
voltageProbeUpperNonCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.11
Description
Defines the user-assigned value of the voltage probe’s upper
noncritical threshold.
Syntax
DellSigned32BitRange
Access
Read-write
Voltage Probe Lower Noncritical Threshold
136
Name
voltageProbeLowerNonCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.12
Description
Defines the user-assigned value of the voltage probe’s lower
noncritical threshold.
Syntax
DellSigned32BitRange
Access
Read-write
Power Group
Voltage Probe Lower Critical Threshold
Name
voltageProbeLowerCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.13
Description
Defines the value of the voltage probe’s lower critical threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Voltage Probe Lower Nonrecoverable Threshold
Name
voltageProbeLowerNonRecoverableThreshold
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.14
Description
Defines the value of the voltage probe’s lower nonrecoverable
threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Voltage Probe Probe Capabilities
Name
voltageProbeProbeCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.15
Description
Defines the probe capabilities of the voltage probe.
Syntax
DellProbeCapabilities
Access
Read-only
Voltage Probe Discrete Reading
Name
voltageProbeDiscreteReading
Object ID
1.3.6.1.4.1.674.10892.1.600.20.1.16
Description
Defines the reading for a voltage probe of type
voltageProbeTypeIsDiscrete.
When the value for voltageProbeType is other than
voltageProbeTypeIsDiscrete, a value is not returned for this
attribute. When the value for voltageProbeType is
voltageProbeTypeIsDiscrete, the value returned for this attribute
is the discrete reading for the probe.
Syntax
DellVoltageDiscreteReading
Access
Read-only
Power Group
137
Amperage Probe Table
Name
amperageProbeTable
Object ID
1.3.6.1.4.1.674.10892.1.600.30
Description
Defines the Amperage Probe Table.
Syntax
SEQUENCE OF AmperageProbeTableEntry
Access
Not accessible
Amperage Probe Table Entry
Name
amperageProbeTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1
Description
Defines the Amperage Probe Table entry.
Syntax
AmperageProbeTableEntry
Access
Not accessible
Index
amperageProbechassisIndex, amperageProbeIndex
Amperage Probe Chassis Index
Name
amperageProbechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Amperage Probe Index
138
Name
amperageProbeIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.2
Description
Defines the index of amperage probes in this chassis.
Syntax
DellObjectRange
Access
Read-only
Power Group
Amperage Probe State Capabilities
Name
amperageProbeStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.3
Description
Defines the capabilities of the amperage probe.
Syntax
DellStateCapabilities
Access
Read-only
Amperage Probe State Settings
Name
amperageProbeStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.4
Description
Defines the state and settings of the amperage probe.
Syntax
DellStateSettings
Access
Read-write
Amperage Probe Status
Name
amperageProbeStatus
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.5
Description
Defines the status of the amperage probe.
Syntax
DellSigned32BitRange
Access
Read-only
Amperage Probe Reading
Name
amperageProbeReading
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.6
Description
Defines the value of the amperage probe.
When the value for amperageProbeType is other than
amperageProbeTypeIsDiscrete, the value returned for this
attribute is the amperage that the probe is reading in milliamps.
When the value for amperageProbeType is
amperageProbeTypeIsDiscrete, a value is not returned for this
attribute.
Syntax
DellSigned32BitRange
Access
Read-only
Power Group
139
Amperage Probe Type
Name
amperageProbeType
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.7
Description
Defines the type of the amperage probe.
Syntax
DellAmperageProbeType
Access
Read-only
Amperage Probe Location Name
Name
amperageProbeLocationName
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.8
Description
Defines the location name of the amperage probe in this chassis.
Syntax
DellString
Access
Read-only
Amperage Probe Upper Nonrecoverable Threshold
Name
amperageProbeUpperNonRecoverableThreshold
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.9
Description
Defines the value of the amperage probe’s upper nonrecoverable
threshold. The value is an integer representing the amperage in
milliamperes that the probe is reading.
Syntax
DellSigned32BitRange
Access
Read-only
Amperage Probe Upper Critical Threshold
140
Name
amperageProbeUpperCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.10
Description
Defines the value of the amperage probe’s upper critical
threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Power Group
Amperage Probe Upper Noncritical Threshold
Name
amperageProbeUpperNonCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.11
Description
Defines the user-assigned value of the amperage probe’s upper
critical threshold.
Syntax
DellSigned32BitRange
Access
Read-write
Amperage Probe Lower Noncritical Threshold
Name
amperageProbeLowerNonCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.12
Description
Defines the user-assigned value of the amperage probe’s lower
noncritical threshold.
Syntax
DellSigned32BitRange
Access
Read-write
Amperage Probe Lower Critical Threshold
Name
amperageProbeLowerCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.13
Description
Defines the value of the amperage probe’s lower
critical threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Amperage Probe Lower Nonrecoverable Threshold
Name
amperageProbeLowerNonRecoverableThreshold
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.14
Description
Defines the value of the amperage probe’s lower
nonrecoverable threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Power Group
141
Amperage Probe Probe Capabilities
Name
amperageProbeProbeCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.15
Description
Defines the probe capabilities of the amperage probe.
Syntax
DellProbeCapabilities
Access
Read-only
Amperage Probe Discrete Reading
Name
amperageProbeDiscreteReading
Object ID
1.3.6.1.4.1.674.10892.1.600.30.1.16
Description
Defines the reading for a amperage probe of type
amperageProbeTypeIsDiscrete.
When the value for amperageProbeType is other than
amperageProbeTypeIsDiscrete, a value is not returned for this
attribute. When the value for amperageProbeType is
amperageProbeTypeIsDiscrete, the value returned for this
attribute is the discrete reading for the probe.
Syntax
DellAmperageDiscreteReading (See Table 8-9)
Access
Read-only
AC Power Switch Table
Name
aCPowerSwitchTable
Object ID
1.3.6.1.4.1.674.10892.1.600.40
Description
Defines the AC Power Switch Table.
Syntax
SEQUENCE OF ACPowerSwitchTableEntry
Access
Not accessible
AC Power Switch Table Entry
142
Name
aCPowerSwitchTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.600.40.1
Description
Defines the AC Power Switch Table entry.
Syntax
ACPowerSwitchTableEntry
Access
Not accessible
Power Group
AC Power Switch Chassis Index
Name
aCPowerSwitchChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.40.1.1
Description
Defines the index (one-based) of the chassis containing this
AC power switch.
Syntax
DellObjectRange
Access
Read-only
AC Power Switch Index
Name
aCPowerSwitchIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.40.1.2
Description
Defines the index (one-based) of this AC power switch.
Syntax
DellObjectRange
Access
Read-only
AC Power Switch Capabilities
Name
aCPowerSwitchCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.600.40.1.3
Description
Defines the capabilities of this AC power switch.
Syntax
DellACPowerSwitchCapabilities
Access
Read-only
AC Power Switch Settings
Name
aCPowerSwitchSettings
Object ID
1.3.6.1.4.1.674.10892.1.600.40.1.4
Description
Defines the settings of this AC power switch.
Syntax
DellACPowerSwitchSettings
Access
Read-write
Power Group
143
AC Power Switch Redundancy Status
Name
aCPowerSwitchRedundancyStatus
Object ID
1.3.6.1.4.1.674.10892.1.600.40.1.5
Description
Defines the redundancy status of this AC power switch.
Syntax
DellStatusRedundancy
Access
Read-only
AC Power Cord Count for Redundancy
Name
aCPowerCordCountForRedundancy
Object ID
1.3.6.1.4.1.674.10892.1.600.40.1.6
Description
Defines the total number of AC power cords required for this
AC power switch to have redundancy.
Syntax
DellObjectRange
Access
Read-only
AC Power Switch Name
Name
aCPowerSwitchName
Object ID
1.3.6.1.4.1.674.10892.1.600.40.1.7
Description
Defines the name of this AC power switch.
Syntax
DellString
Access
Read-only
AC Power Switch Redundancy Mode
144
Name
aCPowerSwitchRedundancyMode
Object ID
1.3.6.1.4.1.674.10892.1.600.40.1.8
Description
Defines the redundancy mode of this AC power switch.
Syntax
DellACPowerSwitchRedundancyMode
Access
Read-write
Power Group
AC Power Switch Status
Name
aCPowerSwitchStatus
Object ID
1.3.6.1.4.1.674.10892.1.600.40.1.9
Description
Defines the status of this AC power switch.
Syntax
DellStatus
Access
Read-only
AC Power Cord Table
Name
aCPowerCordTable
Object ID
1.3.6.1.4.1.674.10892.1.600.42
Description
Defines the AC Power Cord Table.
Syntax
SEQUENCE OF ACPowerCordTableEntry
Access
Not accessible
AC Power Cord Table Entry
Name
aCPowerCordTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.600.42.1
Description
Defines the AC Power Cord Table entry.
Syntax
ACPowerCordTableEntry
Access
Not accessible
AC Power Cord Chassis Index
Name
aCPowerCordChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.42.1.1
Description
Defines the index (one-based) of the chassis containing this
AC power cord.
Syntax
DellObjectRange
Access
Read-only
Power Group
145
AC Power Cord Index
Name
aCPowerCordIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.42.1.2
Description
Defines the index (one-based) of this AC power cord.
Syntax
DellObjectRange
Access
Read-only
AC Power Cord State Capabilities
Name
aCPowerCordStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.600.42.1.3
Description
Defines the capabilities of this AC power cord.
Syntax
DellACPowerCordStateCapabilities
Access
Read-only
AC Power Cord State Settings
Name
aCPowerCordStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.600.42.1.4
Description
Defines the settings of this AC power cord.
Syntax
DellACPowerCordStateSettings
Access
Read-write
AC Power Cord Status
146
Name
aCPowerCordStatus
Object ID
1.3.6.1.4.1.674.10892.1.600.42.1.5
Description
Defines the status of this AC power cord.
Syntax
DellStatus
Access
Read-only
Power Group
AC Power Cord AC Power Switch Index Reference
Name
aCPowerCordaCPowerSwitchIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.600.42.1.6
Description
Defines the index (one-based) to the associated AC power switch
for this AC power cord.
Syntax
DellObjectRange
Access
Read-only
AC Power Cord Location Name
Name
aCPowerCordLocationName
Object ID
1.3.6.1.4.1.674.10892.1.600.42.1.7
Description
Defines the location name of this AC power cord.
Syntax
DellString
Access
Read-only
Battery Table
Name
batteryTable
Object ID
1.3.6.1.4.1.674.10892.1.600.50
Description
Defines the Battery Table.
Syntax
SEQUENCE OF BatteryTableEntry
Access
Not accessible
Battery Table Entry
Name
batteryTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.600.50.1
Description
Defines the Battery Table Entry.
Syntax
BatteryTableEntry
Access
Not accessible
Power Group
147
Battery Chassis Index
Name
batteryChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.50.1.1
Description
Defines the index (one-based) of the chassis that contains the
battery.
Syntax
DellObjectRange
Access
Read-only
Battery Index
Name
batteryIndex
Object ID
1.3.6.1.4.1.674.10892.1.600.50.1.2
Description
Defines the index (one-based) of the battery.
Syntax
DellObjectRange
Access
Read-only
Battery State Capabilities
Name
batteryStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.600.50.1.3
Description
Defines the state capabilities of the battery.
Syntax
DellStateCapabilities
Access
Read-only
Battery State Settings
148
Name
batteryStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.600.50.1.4
Description
Defines the state settings of the battery.
Syntax
DellStateSettings
Access
Read-write
Power Group
Battery Status
Name
batteryStatus
Object ID
1.3.6.1.4.1.674.10892.1.600.50.1.5
Description
Defines the status of the battery.
Syntax
DellStatus
Access
Read-only
Battery Reading
Name
batteryReading
Object ID
1.3.6.1.4.1.674.10892.1.600.50.1.6
Description
Defines the reading of the battery.
Syntax
DellBatteryReading (see Table )
Access
Read-only
Battery Location Name
Name
batteryLocationName
Object ID
1.3.6.1.4.1.674.10892.1.600.50.1.7
Description
Defines the location of the battery.
Syntax
DellString
Access
Read-only
Power Group Variable Values
This section includes definitions for server administrator-specific variable values used in this section.
Table 8-1.
Power Supply State Capabilities Unique
Variable Name: DellPowerSupplyStateCapabilitiesUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
The power supply’s capabilities are unknown.
onlineCapable(2)
The power supply can be disabled (offline, a binary 0 value) or
enabled (online, a binary 1 value).
notReadyCapable(4)
The power supply’s capabilities are not ready.
Power Group
149
Table 8-2.
Power Supply State Settings Unique
Variable Name: DellPowerSupplyStateSettingsUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
The power supply’s capabilities are unknown.
onLine(2)
The power supply’s state is disabled (offline, a binary 0 value) or
enabled (online, a binary 1 value).
notReady(4)
The power supply’s state is not ready.
fanFailure(8)
The power supply fan has failed.
onlineAndFanFailure(10)
The power supply is online and indicating that its fan is
not working.
powerSupplyIsON(16)
The power supply is indicating that it is on.
powerSupplyIsOk(32)
The power supply is indicating that it is OK.
acSwitchIsON(64)
The power supply is indicating that the AC power switch is on.
onlineandAcSwitchIsON(66)
The power supply is online and indicating that the AC power
supply switch capability is activated.
acPowerIsON(128)
The power supply is indicating that the AC power is on.
onlineAndAcPowerIsON(130)
The power supply is online and indicating that the AC power is on.
onlineAndPredictiveFailure(210)
The power supply is online and indicating that it has a problem.
acPowerAndSwitchAreOnPowerSupplyIs The power supply is online and OK.
OnIsOkAndOnline(242)
Table 8-3.
Power Supply Type Definitions
Variable Name: DellPowerSupplyType
Data Type: Integer
150
Possible Data Values
Meaning of Data Value
powerSupplyTypeIsOther(1)
The power supply type is not one of the following:
powerSupplyTypeIsUnknown(2)
The power supply type is unknown (not known or
not monitored).
powerSupplyTypeIsLinear(3)
The power supply type is a linear power supply.
powerSupplyTypeIsSwitching(4)
The power supply type is a switching power supply.
powerSupplyTypeIsBattery(5)
The power supply type is a battery.
powerSupplyTypeIsUPS(6)
The power supply type is an uninterruptable power supply.
Power Group
Table 8-3.
Power Supply Type Definitions (continued)
Variable Name: DellPowerSupplyType
Data Type: Integer
Possible Data Values
Meaning of Data Value
powerSupplyTypeIsConverter(7)
The power supply type is a power converter power supply.
powerSupplyTypeIsRegulator(8)
The power supply type is a regulator power supply.
powerSupplyTypeIsAC(9)
The power supply type is an AC power supply.
powerSupplyTypeIsDC(10)
The power supply type is a DC power supply.
powerSupplyTypeIsVRM(11)
The power supply type is a voltage regulator module (VRM)
power supply.
Table 8-4.
Power Supply Sensor State
Variable Name: DellPowerSupplySensorState
Data Type: Integer
Possible Data Values
Meaning of Data Value
presenceDetected(1)
The power supply’s presence is detected.
psFailureDetected(2)
The power supply failure is detected.
predictiveFailure(4)
The power supply sensor detects predictive failure
psACLost(8)
The power supply’s AC power is lost.
acLostOrOutOfRange(16)
The power supply’s AC power is lost or out of range.
acOutOfRangeButPresent(32)
The power supply’s AC power is present, but it is out of range.
configurationError(64)
The power supply sensor detects a configuration error.
Table 8-5.
Power Supply Configuration Error Type
Variable Name: DellPowerSupplyConfigurationErrorType
Data Type: Integer
Possible Data Values
Meaning of Data Value
vendorMismatch(1)
The power supply configuration error type is vendor mismatch.
revisionMismatch(2)
The power supply configuration error type is revision mismatch.
processorMissing(3)
The power supply configuration error type is processor missing.
Power Group
151
Table 8-6.
Voltage Probe Type
Variable Name: DellVoltageType
Data Type: Integer
Possible Data Values
Meaning of Data Value
voltageProbeTypeIsOther(1)
The voltage probe type is not one of the following:
voltageProbeTypeIsUnknown(2)
The voltage probe type is unknown (not known or not monitored).
voltageProbeTypeIs1Point5Volt(3)
The voltage probe type is a 1.5-volt (V) probe.
voltageProbeTypeIs3Point3Volt(4)
The voltage probe type is a 3.3-V probe.
voltageProbeTypeIs5Volt(5)
The voltage probe type is a 5-V probe.
voltageProbeTypeIsMinus5Volt(6)
The voltage probe type is a –5-V probe.
voltageProbeTypeIs12Volt(7)
The voltage probe type is a 12-V probe.
voltageProbeTypeIsMinus12Volt(8)
The voltage probe type is a –12-V probe.
voltageProbeTypeIsIO(9)
The voltage probe type is an I/O volt probe.
voltageProbeTypeIsCore(10)
The voltage probe type is a core volt probe.
voltageProbeTypeIsFLEA(11)
The voltage probe type is a FLEA (standby) volt probe.
voltageProbeTypeIsBattery(12)
The voltage probe type is a battery volt probe.
voltageProbeTypeIsTerminator(13)
The voltage probe type is a SCSI termination volt probe.
voltageProbeTypeIs2Point5Volt(14)
The voltage probe type is a 2.5-V probe.
voltageProbeTypeIsGTL(15)
The voltage probe type is a ground termination logic (GTL) probe.
voltageProbeTypeIsDiscrete(16)
The voltage probe type is a voltage probe with discrete reading.
Table 8-7.
Voltage Probe Discrete Reading
Variable Name: DellVoltageDiscreteReading
Data Type: Integer
152
Possible Data Values
Meaning of Data Value
voltageIsGood(1)
The voltage probe discrete reading is good.
voltageIsBad(2)
The voltage probe discrete reading is bad.
Power Group
Table 8-8.
Amperage Probe Definitions
Variable Name: DellAmperageType
Data Type: Integer
Possible Data Values
Meaning of Data Value
amperageProbeTypeIsOther(1)
The amperage probe type is not one of the following:
amperageProbeTypeIsUnknown(2)
The amperage probe type is unknown (not known or
not monitored).
amperageProbeTypeIs1Point5Volt(3)
The amperage probe type is a 1.5-ampere (A) probe.
amperageProbeTypeIs3Point3volt(4)
The amperage probe type is a 3.3-A probe.
amperageProbeTypeIs5Volt(5)
The amperage probe type is a 5-A probe.
amperageProbeTypeIsMinus5Volt(6)
The amperage probe type is a –5-A probe.
amperageProbeTypeIs12Volt(7)
The amperage probe type is a 12-A probe.
amperageProbeTypeIsMinus12Volt(8)
The amperage probe type is a –12-A probe.
amperageProbeTypeIsIO(9)
The amperage probe type is an I/O amperage probe.
amperageProbeTypeIsCore(10)
The amperage probe type is a core amperage probe.
amperageProbeTypeIsFLEA(11)
The amperage probe type is a FLEA (standby) amperage probe.
amperageProbeTypeIsBattery(12)
The amperage probe type is a battery amperage probe.
amperageProbeTypeIsTerminator(13)
The amperage probe type is a Small Computer System
Interface (SCSI) termination amperage probe.
amperageProbeTypeIs2Point5Volt(14) The amperage probe type is a 2.5-V amperage probe.
amperageProbeTypeIsGTL(15)
The amperage probe type is a Gunning Transceiver Logic (GTL)
probe.
amperageProbeTypeIsDiscrete(16)
The amperage probe type is an amperage probe with
discrete reading.
Table 8-9.
Amperage Probe Discrete Reading
Variable Name: DellAmperageDiscreteReading
Data Type: Integer
Possible Data Values
Meaning of Data Value
amperageIsGood(1)
The amperage probe discrete reading is good.
amperageIsBad(2)
The amperage probe discrete reading is bad.
Power Group
153
Table 8-10.
AC Power Switch Capabilities
Variable Name: DellACPowerSwitchCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknownCapabilities(1)
The AC power switch’s capabilities are unknown.
inputSourceCord1NoReturnCapable(2) Input source is AC power cord 1, with no return.
inputSourceCord1ReturnCapable(4)
Input source is AC power cord 1, with return.
inputSourceCord2NoReturnCapable(8) Input source is AC power cord 2, with no return.
inputSourceCord2ReturnCapable(16)
Input source is AC power cord 2, with return.
inputSourceSharedCapable(32)
Input source is shared.
Table 8-11.
AC Power Switch Settings
Variable Name: DellACPowerSwitchSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
The AC power switch’s settings are unknown.
inputSourceCord1NoReturn(2)
Input source is AC power cord 1, with no return.
inputSourceCord1Return(4)
Input source is AC power cord 1, with return.
inputSourceCord2NoReturn(8)
Input source is AC power cord 2, with no return.
inputSourceCord2Return(16)
Input source is AC power cord 2, with return.
inputSourceShared(32)
Input source is shared.
Table 8-12.
AC Power Switch Redundancy Mode
Variable Name: DellACPowerSwitchRedundancyMode
Data Type: Integer
154
Possible Data Values
Meaning of Data Value
nonRedundant(1)
The AC power switch is not expecting redundancy.
redundant(2)
The AC power switch is expecting redundancy.
Power Group
Table 8-13.
AC Power Cord State Capabilities
Variable Name: DellACPowerCordStateCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
The AC power cord’s capabilities are unknown.
onlineCapable(2)
The AC power cord can be disabled (offline) or enabled (online).
notReadyCapable(4)
The AC power cord’s capabilities are not ready.
Table 8-14.
AC Power Cord State Settings
Variable Name: DellACPowerCordStateSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
The AC power cord’s state is unknown.
online(2)
The AC power cord’s state is disabled (offline) 0 or enabled (online) 1.
notReady(4)
The AC power cord’s state is not ready.
acPowerCordHasPower(8)
The AC power cord has power.
acPowerCordIsActiveSource(16) The AC power cord is the active source of AC power.
Table 8-15. Battery Reading
Variable Name: DellBatteryReading
Data Type: Integer
NOTE: These values are bit masks, so combination values are possible.
Possible Data Values
Meaning of Data Value
predictiveFailure(1)
Battery sensor detects predictive failure.
failed(2)
Battery has failed.
presenceDetected(4)
Battery presence is detected.
Power Group
155
156
Power Group
Thermal Group
The Thermal Group provides information about cooling units, cooling devices, and temperature
probes. Cooling units are sets of fans or other cooling devices in a system chassis. Thermal Group
variables include threshold values and types of cooling devices and temperature probes.
Thermal Group Tables
The following management information base (MIB) tables define the objects in the Thermal Group:
•
Cooling Unit Table
•
Cooling Unit Status
•
Temperature Probe Table
Cooling Unit Table
Name
coolingUnitTable
Object ID
1.3.6.1.4.1.674.10892.1.700.10
Description
Defines the Cooling Unit Table.
Syntax
TableEntry
Access
Not accessible
Cooling Unit Table Entry
Name
coolingUnitTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.700.10.1
Description
Defines the Cooling Unit Table entry.
Syntax
TableEntry
Access
Not accessible
Index
coolingUnitchassisIndex, coolingUnitIndex
Thermal Group
157
Cooling Unit Chassis Index
Name
coolingUnitchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.700.10.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
TableEntry
Access
Read-only
Cooling Unit Index
Name
coolingUnitIndex
Object ID
1.3.6.1.4.1.674.10892.1.700.10.1.2
Description
Defines the index (one-based) of cooling units.
Syntax
DellObjectRange
Access
Read-only
Cooling Unit State Capabilities
Name
coolingUnitStateCapabilties
Object ID
1.3.6.1.4.1.674.10892.1.700.10.1.3
Description
Defines the capabilities of the cooling unit.
Syntax
DellStateCapabilities
Access
Read-only
Cooling Unit State Settings
158
Name
coolingUnitStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.700.10.1.4
Description
Defines the state and settings of the cooling unit.
Syntax
DellStateSettings
Access
Read-write
Thermal Group
Cooling Unit Redundancy Status
Name
coolingUnitRedundancyStatus
Object ID
1.3.6.1.4.1.674.10892.1.700.10.1.5
Description
Defines the redundancy status of the cooling unit.
Syntax
DellStatusRedundancy
Access
Read-only
Cooling Device Count For Redundancy
Name
coolingDeviceCountForRedundancy
Object ID
1.3.6.1.4.1.674.10892.1.700.10.1.6
Description
Defines the total number of cooling devices required for this cooling
unit to have redundancy.
Syntax
DellObjectRange
Access
Read-only
Cooling Unit Name
Name
coolingUnitName
Object ID
1.3.6.1.4.1.674.10892.1.700.10.1.7
Description
Defines the cooling unit name in this chassis.
Syntax
DellString
Access
Read-only
Cooling Unit Status
Name
coolingUnitStatus
Object ID
1.3.6.1.4.1.674.10892.1.700.10.1.8
Description
Defines the status of the cooling unit in this chassis.
Syntax
DellStatus
Access
Read-only
Thermal Group
159
Cooling Device Table
Name
coolingDeviceTable
Object ID
1.3.6.1.4.1.674.10892.1.700.12
Description
Defines the Cooling Device Table.
Syntax
CoolingDeviceTableEntry
Access
Not accessible
Cooling Device Table Entry
Name
coolingDeviceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1
Description
Defines the Cooling Device Table entry.
Syntax
CoolingDeviceTableEntry
Access
Not accessible
Index
cooling DevicechassisIndex, coolingDeviceIndex
Cooling Device Chassis Index
Name
coolingDevicechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Cooling Device Index
160
Name
coolingDeviceIndex
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.2
Description
Defines the index of cooling devices in this chassis.
Syntax
DellObjectRange
Access
Read-only
Thermal Group
Cooling Device State Capabilities
Name
coolingDeviceStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.3
Description
Defines the capabilities of the cooling device.
Syntax
DellStateCapabilities
Access
Read-only
Cooling Device State Settings
Name
coolingDeviceStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.4
Description
Defines the state and settings of the cooling device.
Syntax
DellStateSettings
Access
Read-write
Cooling Device Status
Name
coolingDeviceStatus
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.5
Description
Defines the status of the cooling device.
Syntax
DellStatusProbe
Access
Read-only
Cooling Device Reading
Name
coolingDeviceReading
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.6
Description
Defines either the cooling device’s speed in revolutions per minute (RPM),
or the off/on value of the fan.
When the value for coolingDeviceSubType is other than
coolingDeviceSubTypeIsDiscrete, the value returned for this attribute is the
speed in RPM or the OFF/ON value of the cooling device. When the value
for coolingDeviceSubType is coolingDeviceSubTypeIsDiscrete, a value is
not returned for this attribute.
Syntax
DellSigned32BitRange
Access
Read-only
Thermal Group
161
Cooling Device Type
Name
coolingDeviceType
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.7
Description
Defines the cooling device type.
Syntax
DellCoolingDeviceType (See Table 9-1.)
Access
Read-only
Cooling Device Location Name
Name
coolingDeviceLocationName
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.8
Description
Defines the location of the cooling device in this chassis.
Syntax
DellString
Access
Read-only
Cooling Device Upper Nonrecoverable Threshold
Name
coolingDeviceUppernonrecoverableThreshold
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.9
Description
Defines the value of the fan’s upper nonrecoverable threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Cooling Device Upper Critical Threshold
162
Name
coolingDeviceUpperCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.10
Description
Defines the value of the fan’s upper critical threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Thermal Group
Cooling Device Upper Noncritical Threshold
Name
coolingDeviceUpperNonCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.11
Description
Defines the user-assigned value of the fan’s upper noncritical threshold.
Syntax
DellSigned32BitRange
Access
Read-write
Cooling Device Lower Noncritical Threshold
Name
coolingDeviceLowerNonCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.12
Description
Defines the user-assigned value of the fan’s lower noncritical threshold.
Syntax
DellSigned32BitRange
Access
Read-write
Cooling Device Lower Critical Threshold
Name
coolingDeviceLowerCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.13
Description
Defines the value of the fan’s lower critical threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Cooling Device Lower Nonrecoverable Threshold
Name
coolingDeviceLowerNonRecoverableThreshold
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.14
Description
Defines the value of the fan’s lower nonrecoverable threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Thermal Group
163
Cooling Device Cooling Unit Index Reference
Name
coolingDevicecoolingUnitIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.15
Description
Defines the index for the associated system cooling unit in this chassis.
Syntax
DellObjectRange
Access
Read-only
Cooling Device Subtype
Name
coolingDeviceSubType
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.16
Description
Defines the cooling device subtype.
Syntax
DellCoolingDeviceSubType (See Table 9-2.)
Access
Read-only
Cooling Device Probe Capabilities
Name
coolingDeviceProbeCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.17
Description
Defines the probe capabilities of the cooling device.
Syntax
DellProbeCapabilities
Access
Read-only
Cooling Device Discrete Reading
Name
coolingDeviceDiscreteReading
Object ID
1.3.6.1.4.1.674.10892.1.700.12.1.18
Description
Defines the reading for a voltage probe of type
coolingDeviceSubTypeIsDiscrete.
When the value for coolingDeviceSubType is other than
coolingDeviceSubTypeIsDiscrete, a value is not returned for this
attribute. When the value for coolingDeviceSubType is
coolingDeviceSubTypeIsDiscrete, the value returned for this
attribute is the discrete reading for the cooling device.
164
Syntax
DellCoolingDeviceDiscreteReading (See Table 9-3)
Access
Read-only
Thermal Group
Temperature Probe Table
Name
temperatureProbeTable
Object ID
1.3.6.1.4.1.674.10892.1.700.20
Description
Defines the Temperature Probe Table.
Syntax
TemperatureProbeTableEntry
Access
Not accessible
Temperature Probe Table Entry
Name
temperatureProbeTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1
Description
Defines the Temperature Probe Table entry.
Syntax
TemperatureProbeTableEntry
Access
Not accessible
Index
temperatureProbechassisIndex,
temperatureProbeIndex
Temperature Probe Chassis Index
Name
temperatureProbechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Temperature Probe Index
Name
temperatureProbeIndex
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.2
Description
Defines the index of temperature probes in this chassis.
Syntax
DellObjectRange
Access
Read-only
Thermal Group
165
Temperature Probe State Capabilities
Name
temperatureProbeStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.3
Description
Defines the capabilities of the temperature probe.
Syntax
DellStateCapabilities
Access
Read-only
Temperature Probe State Settings
Name
temperatureProbeStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.4
Description
Defines the state and settings of the temperature probe.
Syntax
DellStateSettings
Access
Read-write
Temperature Probe Status
Name
temperatureProbeStatus
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.5
Description
Defines the status of the temperature probe in tenths of degrees Celsius.
Syntax
DellStatusProbe
Access
Read-only
Temperature Probe Reading
Name
temperatureProbeReading
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.6
Description
Defines the value of the temperature probe.
When the value for temperatureProbeType is other than
temperatureProbeTypeIsDiscrete, the value returned for this
attribute is the temperature that the probe is reading in tenths of
degrees Centigrade. When the value for temperatureProbeType is
temperatureProbeTypeIsDiscrete, a value is not returned for
this attribute.
166
Syntax
DellSigned32BitRange
Access
Read-only
Thermal Group
Temperature Probe Type
Name
temperatureProbeType
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.7
Description
Defines the temperature probe type.
Syntax
DellTemperatureProbeType (See Table 9-4.)
Access
Read-only
Temperature Probe Location Name
Name
temperatureProbeLocationName
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.8
Description
Defines the location of the temperature probe in this chassis.
Syntax
DellString
Access
Read-only
Temperature Probe Upper Nonrecoverable Threshold
Name
temperatureProbeUpperNonRecoverableThreshold
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.9
Description
Defines the value of the temperature probe’s upper
nonrecoverable threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Temperature Probe Upper Critical Threshold
Name
temperatureProbeUpperCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.10
Description
Defines the value of the temperature probe’s upper critical threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Thermal Group
167
Temperature Probe Upper Noncritical Threshold
Name
temperatureProbeUpperNonCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.11
Description
Defines the user-assigned value of the temperature probe’s upper
noncritical threshold.
Syntax
DellSigned32BitRange
Access
Read-write
Temperature Probe Lower Noncritical Threshold
Name
temperatureProbeLowerNonCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.12
Description
Defines the user-assigned value of the temperature probe’s lower
noncritical threshold.
Syntax
DellSigned32BitRange
Access
Read-write
Temperature Probe Lower Critical Threshold
Name
temperatureProbeLowerCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.13
Description
Defines the value of the temperature probe’s lower critical threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Temperature Probe Lower Nonrecoverable Threshold
168
Name
temperatureProbeLowerNonRecoverableThreshold
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.14
Description
Defines the value of the temperature probe’s lower
nonrecoverable threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Thermal Group
Temperature Probe Probe Capabilities
Name
temperatureProbeProbeCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.15
Description
Defines the probe capabilities of the temperature probe.
Syntax
DellProbeCapabilities
Access
Read-only
Temperature Probe Discrete Reading
Name
temperatureProbeDiscreteReading
Object ID
1.3.6.1.4.1.674.10892.1.700.20.1.16
Description
Defines the reading for a temperature probe of type
temperatureProbeTypeIsDiscrete.
When the value for temperatureProbeType is other than
temperatureProbeTypeIsDiscrete, a value is not returned for this
attribute. When the value for temperatureProbeType is
temperatureProbeTypeIsDiscrete, the value returned for this
attribute is the discrete reading for the probe.
Syntax
DellTemperatureDiscreteReading (See Table 9-5)
Access
Read-only
Thermal Group Variable Values
This section includes definitions for server administrator-specific variable values used in this section.
Table 9-1.
Cooling Device Type
Variable Name: DellCoolingDeviceType
Data Type: Integer
Possible Data Values
Meaning of Data Value
coolingDeviceTypeIsOther(1)
The cooling device type is not one of the following:
coolingDeviceTypeIsUnknown(2)
The cooling device type is unknown (not known or not
monitored).
coolingDeviceTypeIsAFan(3)
The cooling device type is a fan.
coolingDeviceTypeIsABlower(4)
The cooling device type is a centrifugal blower.
coolingDeviceTypeIsAChipFan(5)
The cooling device type is a fan on an integrated circuit.
coolingDeviceTypeIsACabinetFan(6)
The cooling device type is a cabinet fan.
Thermal Group
169
Table 9-1.
Cooling Device Type (continued)
Variable Name: DellCoolingDeviceType
Data Type: Integer
Possible Data Values
Meaning of Data Value
coolingDeviceTypeIsAPowerSupplyFan(7) The cooling device type is a power supply fan.
coolingDeviceTypeIsAHeatPipe(8)
The cooling device type is a heat pipe.
coolingDeviceTypeIsRefrigeration(9)
The cooling device type is an integrated refrigeration unit.
coolingDeviceTypeIsActiveCooling(10)
The cooling device type is an active cooling device.
coolingDeviceTypeIsPassiveCooling(11) The cooling device type is a passive cooling device.
Table 9-2.
Cooling Device Subtype
Variable Name: DellCoolingDeviceSubType
Data Type: Integer
Possible Data Values
Meaning of Data Value
coolingDeviceSubTypeIsOther(1)
The cooling device subtype is not one of the following:
coolingDeviceSubTypeIsUnknown(2)
The cooling device subtype is unknown (not known or
not monitored).
coolingDeviceSubTypeIsAFanThatReadsIn The cooling device subtype is a fan that reads in RPMs.
RPM(3)
coolingDeviceSubTypeIsAFanReadsONorOFF The cooling device subtype is a fan that reads 0 (off)
(4)
or 1 (on).
coolingDeviceSubTypeIsAPowerSupplyFan The cooling device subtype is a power supply fan that reads
ThatReadsinRPM(5)
in RPMs.
coolingDeviceSubTypeIsAPowerSupplyFan The cooling device subtype is a power supply fan that
ThatReads- ONorOFF(6)
reads 0 (off) or 1 (on).
coolingDeviceSubTypeIsDiscrete(16)
Table 9-3.
The cooling device subtype is a cooling device with
discrete reading.
Cooling Device Discrete Reading
Variable Name: DellCoolingDeviceDiscreteReading
Data Type: Integer
170
Possible Data Values
Meaning of Data Value
coolingDeviceIsGood(1)
The cooling device discrete reading is good.
coolingDeviceIsBad(2)
The cooling device discrete reading is bad.
Thermal Group
Table 9-4.
Temperature Probe Type
Variable Name: DellTemperatureProbeType
Data Type: Integer
Possible Data Values
Meaning of Data Value
temperatureProbeTypeIsOther(1)
The temperature probe subtype is not one of the following:
temperatureProbeTypeIsUnknown(2)
The temperature probe subtype is unknown (not known or
not monitored).
temperatureProbeTypeIsAmbientESM(3)
The temperature probe is for ambient Embedded Systems
Management (ESM).
temperatureProbeTypeIsDiscrete(16)
The temperature probe subtype is a temperature probe
with discrete reading.
Table 9-5.
Temperature Probe Discrete Reading
Variable Name: DellTemperatureDiscreteReading
Data Type: Integer
Possible Data Values
Meaning of Data Value
temperatureIsGood(1)
The temperature probe discrete reading is good.
temperatureIsBad(2)
The temperature probe discrete reading is bad.
Thermal Group
171
172
Thermal Group
User Security Group
The User Security Table defines the objects that allow administrators to create and modify
user accounts and to control which users can perform Set operations on managed systems.
User Security Group Table
The User Security Group defines objects in the User Security MIB table.
User Security Table
The following object sets up the User Security Table:
Name
userSecurityTable
Object ID
1.3.6.1.4.1.674.10892.1.800
Description
Contains the database of users that are authorized to perform Set
operations on a managed system.
Syntax
UserSecurityTableEntry
Access
Not accessible
User Security Table Entry
Name
userSecurityTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.800.1
Description
Defines a row in the User Security Table.
Syntax
UserSecurityTableEntry
Access
Not accessible
Index
userSecuritychassisIndex, userSecurityIndex
User Security Chassis Index
Name
userSecuritychassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.800.1.1
Description
Defines the user security index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
User Security Group
173
User Security Index
Name
userSecurityIndex
Object ID
1.3.6.1.4.1.674.10892.1.800.1.2
Description
Defines the user security index.
Syntax
DellObjectRange
Access
Read-only
User Security User Name
Name
userSecurityUserName
Object ID
1.3.6.1.4.1.674.10892.1.800.1.3
Description
Defines the user security user name.
Syntax
DellSecurityString
Access
Read-only
User Security Control Name
Name
userSecurityControlName
Object ID
1.3.6.1.4.1.674.10892.1.800.1.4
Description
Defines a control name used for creating, deleting, and editing users.
Syntax
DellSecurityString
Access
Read-write
User Security Request Name
174
Name
userSecurityRequestName
Object ID
1.3.6.1.4.1.674.10892.1.800.1.5
Description
Defines a request name used for creating, deleting, and editing users.
Syntax
DellSecurityString
Access
Read-write
User Security Group
Remote Flash BIOS Group
The Remote Flash Basic Input/Output System (BIOS) Table defines the variables used to
remotely update the BIOS in a system. The variables also define the capabilities of BIOS updates
on the system.
Remote Flash BIOS Group Table
The Remote Flash BIOS Group defines objects in the Remote Flash BIOS MIB table.
Remote Flash BIOS Table
The following object sets up the Remote Flash BIOS Table:
Name
remoteFlashBIOSTable
Object ID
1.3.6.1.4.1.674.10892.1.900.10
Description
Defines the Remote Flash BIOS Table.
Syntax
RemoteFlashBIOSTableEntry
Access
Not accessible
Remote Flash BIOS Table Entry
Name
remoteFlashBIOSTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.900.10.1
Description
Defines the Remote Flash BIOS Table entry.
Syntax
RemoteFlashBIOSTableEntry
Access
Not accessible
Index
remoteFlashBIOSchassisIndex, remoteFlashBIOSIndex
Remote Flash BIOS Group
175
Remote Flash BIOS Chassis Index
Name
remoteFlashBIOSchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.900.10.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Remote Flash BIOS Index
Name
remoteFlashBIOSIndex
Object ID
1.3.6.1.4.1.674.10892.1.900.10.1.2
Description
Defines the index to the remote BIOS update hardware on this system.
Syntax
DellObjectRange
Access
Read-only
Remote Flash BIOS State Capabilities Unique
Name
remoteFlashBIOSStateCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.900.10.1.3
Description
Defines the capabilities of the remote BIOS update hardware on
this system.
Syntax
DellRemoteFlashBIOSStateCapabilitiesUnique (See Table 11-1.)
Access
Read-only
Remote Flash BIOS State Settings Unique
176
Name
remoteFlashBIOSStateSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.900.10.1.4
Description
Defines the state and settings of the remote BIOS update hardware on
this system.
Syntax
DellRemoteFlashBIOSStateSettingsUnique (See Table 11-2.)
Access
Read-write
Remote Flash BIOS Group
Remote Flash BIOS Status
Name
remoteFlashBIOSStatus
Object ID
1.3.6.1.4.1.674.10892.1.900.10.1.5
Description
Defines the status of the remote BIOS update hardware on
this system.
Syntax
DellRemoteFlashBIOSStateStatus
Access
Read-only
Remote Flash BIOS Last BIOS Date Name
Name
remoteFlashBIOSLastBIOSDateName
Object ID
1.3.6.1.4.1.674.10892.1.900.10.1.6
Description
Defines the date of the last BIOS update.
Syntax
DellDateName
Access
Read-only
Remote Flash BIOS Completion Code
Name
remoteFlashBIOSCompletionCode
Object ID
1.3.6.1.4.1.674.10892.1.900.10.1.7
Description
Defines the completion code of the last BIOS update.
Syntax
DellRemoteFlashBIOSCompletionCode (See Table 11-3.)
Access
Read-only
Remote Flash BIOS Minimum Contiguous Memory
Name
remoteFlashBIOSMinimumContiguousMemory
Object ID
1.3.6.1.4.1.674.10892.1.900.10.1.8
Description
Defines the minimum size of contiguous memory required for remote
BIOS update in kilobytes.
Syntax
DellUnsigned32BitRange
Access
Read-only
Remote Flash BIOS Group
177
Remote Flash BIOS Variable Values
This section includes definitions for server administrator-specific variable values used in this section.
Table 11-1.
Remote Flash BIOS State Capabilities Unique
Variable Name: DellRemoteFlashBIOSStateCapabilitiesUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
The remote flash BIOS’s capabilities are unknown.
enableCapable(2)
The remote flash BIOS can be disabled (offline, a binary 0 value) or
enabled (online, a binary 1 value).
notReadyCapable(4)
The remote flash BIOS can be set to indicate not ready.
cancelCapable(8)
Flash of BIOS can be canceled.
enableAndCancelCapable(10)
Flash of BIOS can be enabled or canceled.
Table 11-2.
Remote Flash BIOS State Settings
Variable Name: DellRemoteFlashBIOSStateSettingsUnique
Data Type: Integer
178
Possible Data Values
Meaning of Data Value
unknown(1)
The remote flash BIOS’s capabilities are unknown.
enabled(2)
The remote flash BIOS update is disabled (offline, a binary 0 value) or
enabled (online, a binary 1 value).
notReady(4)
The remote flash BIOS’s state is not ready.
canceled(8)
The remote flash BIOS has been canceled.
pending(16)
The remote flash BIOS update is pending.
other(32)
The remote flash BIOS state/setting is not one of the previous values.
Remote Flash BIOS Group
Table 11-3.
Remote Flash BIOS Completion Code
Variable Name: DellRemoteFlashBIOSCompletionCode
Data Type: Integer
Possible Data Values
Meaning of Data Value
completionCodeIsOther(1)
The completion code status is not one of the following:
completionCodeIsUnknown(2)
The completion code is unknown (not known or
not monitored).
completionCodeIsOK(3)
This completion code completed successfully.
completionCodeIsBadImage(4)
This completion code is a bad flash BIOS image.
completionCodeIsNoFileAccess(5)
Flash BIOS could not be accessed.
completionCodeIsNotReady(6)
Flash BIOS memory not ready.
completionCodeIsDisabled(7)
Flash BIOS is currently disabled.
completionCodeIsNoBattery(8)
A battery must be installed.
completionCodeIsNoChargedBattery(9)
A fully charged battery must be installed.
completionCodeIsNoExternalPower(10)
An external power adapter must be connected.
completionCodeIsNo12VoltSet(11)
12 volts (V) could not be set.
completionCodeIsNo12VoltRemoval(12)
12 V could not be removed.
completionCodeIsFlashMemoryFailed(13)
A flash memory failure occurred.
completionCodeIsGeneralFailure(14)
A general failure occurred.
completionCodeIsDataMiscompare(15)
A data miscompare error occurred.
completionCodeIsNoImageFound(16)
The flash BIOS image could not be found in memory.
completionCodeIsNoUpdatePerformed(17)
No update operation has been performed.
Remote Flash BIOS Group
179
180
Remote Flash BIOS Group
Port Group
The Port Group provides information about the different types of ports that may be present in your
system. This management information base (MIB) group also provides information about the
capabilities, states, and settings that are possible for each port.
Port Group Tables
The following MIB tables define objects in the Port Group:
•
Pointing Port Table
•
Keyboard Port Table
•
Processor Port Table
•
Memory Device Port Table
•
Monitor Port Table
•
Small Computer System Interface (SCSI) Port Table
•
Parallel Port Table
•
Serial Port Table
•
Universal Serial Bus (USB) Port Table
Pointing Port Table
Name
pointingPortTable
Object ID
1.3.6.1.4.1.674.10892.1.1000.10
Description
Defines the Pointing Port Table.
Syntax
IntegerPointingPortTableEntry
Access
Not accessible
Port Group
181
Pointing Port Table Entry
Name
pointingPortTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1000.10.1
Description
Defines the Pointing Port Table entry.
Syntax
PointingPortTableEntry
Access
Not accessible
Index
pointingPortchassisIndex, pointingPortIndex
Pointing Port Chassis Index
Name
pointingPortchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.10.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Pointing Port Index
Name
pointingPortIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.10.1.2
Description
Defines the index of the pointing ports in this chassis.
Syntax
DellObjectRange
Access
Read-only
Pointing Port State Capabilities
182
Name
pointingPortStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1000.10.3
Description
Defines the capabilities of the pointing port.
Syntax
DellStateCapabilities
Access
Read-only
Port Group
Pointing Port State Settings
Name
pointingPortStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1000.10.4
Description
Defines the state and settings of the pointing port.
Syntax
DellStateSettings
Access
Read-write
Pointing Port Status
Name
pointingPortStatus
Object ID
1.3.6.1.4.1.674.10892.1.1000.10.5
Description
Defines the status of the pointing port.
Syntax
DellStatus
Access
Read-only
Pointing Port Security State
Name
pointingPortSecurityState
Object ID
1.3.6.1.4.1.674.10892.1.1000.10.6
Description
Defines the security settings of the pointing port.
Syntax
DellPortSecurityState
Access
Read-only
Pointing Port Connector Type
Name
pointingPortConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.10.7
Description
Defines the connector type of the pointing port.
Syntax
DellPointingPortConnectorType (See Table 12-1.)
Access
Read-only
Port Group
183
Pointing Port Name
Name
pointingPortName
Object ID
1.3.6.1.4.1.674.10892.1.1000.10.8
Description
Defines the name of the pointing port.
Syntax
DellString
Access
Read-only
Pointing Port BIOS Connector Type
Name
pointingPortBIOSConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.10.9
Description
Defines the basic input/output system (BIOS) connector type of the
pointing port.
Syntax
DellGenericPortConnectorType
Access
Read-only
Keyboard Port Table
Name
keyboardPortTable
Object ID
1.3.6.1.4.1.674.10892.1.1000.20
Description
Defines the Keyboard Port Table.
Syntax
IntegerKeyboardPortTableEntry
Access
Not accessible
Keyboard Port Table Entry
184
Name
keyboardPortTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1000.20.1
Description
Defines the Keyboard Port Table entry.
Syntax
KeyboardPortTableEntry
Access
Not accessible
Index
keyboardPortchassisIndex, keyboardPortIndex
Port Group
Keyboard Port Chassis Index
Name
keyboardPortchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.20.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Keyboard Port Index
Name
keyboardPortIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.20.1.2
Description
Defines the index of the keyboard ports in this chassis.
Syntax
DellObjectRange
Access
Read-only
Keyboard Port State Capabilities
Name
keyboardPortStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1000.20.1.3
Description
Defines the capabilities of the keyboard port.
Syntax
DellStateCapabilities
Access
Read-only
Keyboard Port State Settings
Name
keyboardPortStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1000.20.1.4
Description
Defines the state and settings of the keyboard port.
Syntax
DellStateSettings
Access
Read-only
Port Group
185
Keyboard Port Status
Name
keyboardPortStatus
Object ID
1.3.6.1.4.1.674.10892.1.1000.20.1.5
Description
Defines the status of the keyboard port.
Syntax
DellStatus
Access
Read-only
Keyboard Port Security State
Name
keyboardPortSecurityState
Object ID
1.3.6.1.4.1.674.10892.1.1000.20.1.6
Description
Defines the security settings of the keyboard port.
Syntax
DellPortSecurityState
Access
Read-only
Keyboard Port Connector Type
Name
keyboardPortConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.20.1.7
Description
Defines the connector type of the keyboard port.
Syntax
DellKeyboardPortConnectorType (See Table 12-2.)
Access
Read-only
Keyboard Port Name
186
Name
keyboardPortName
Object ID
1.3.6.1.4.1.674.10892.1.1000.20.1.8
Description
Defines the name of the keyboard port.
Syntax
DellString
Access
Read-only
Port Group
Keyboard Port BIOS Connector Type
Name
keyboardPortBIOSConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.20.1.9
Description
Defines the BIOS connector type of the keyboard port.
Syntax
DellGenericPortConnectorType
Access
Read-only
Processor Port Table
Name
processorPortTable
Object ID
1.3.6.1.4.1.674.10892.1.1000.30
Description
Defines the Processor Port Table.
Syntax
IntegerProcessorPortTableEntry
Access
Not accessible
Processor Port Table Entry
Name
processorPortTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1000.30.1
Description
Defines the Processor Port Table entry.
Syntax
ProcessorPortTableEntry
Access
Not accessible
Index
processorPortchassisIndex, processorPortIndex
Processor Port Chassis Index
Name
processorPortchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.30.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Port Group
187
Processor Port Index
Name
processorPortIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.30.1.2
Description
Defines the index of the processor ports in this chassis.
Syntax
DellObjectRange
Access
Read-only
Processor Port State Capabilities
Name
processorPortStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1000.30.1.3
Description
Defines the capabilities of the processor port.
Syntax
DellStateCapabilities
Access
Read-only
Processor Port State Settings
Name
processorPortStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1000.30.1.4
Description
Defines the state and settings of the processor port.
Syntax
DellStateSettings
Access
Read-write
Processor Port Status
188
Name
processorPortStatus
Object ID
1.3.6.1.4.1.674.10892.1.1000.30.1.5
Description
Defines the status of the processor port.
Syntax
DellStatus
Access
Read-only
Port Group
Processor Port Security State
Name
processorPortSecurityState
Object ID
1.3.6.1.4.1.674.10892.1.1000.30.1.6
Description
Defines the security settings of the processor port.
Syntax
DellPortSecurityState
Access
Read-only
Processor Port Connector Type
Name
processorPortConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.30.1.7
Description
Defines the connector type of the processor port.
Syntax
DellProcessorPortConnectorType (See Table 12-3.)
Access
Read-only
Processor Port Name
Name
processorPortName
Object ID
1.3.6.1.4.1.674.10892.1.1000.30.1.8
Description
Defines name of the processor port.
Syntax
DellString
Access
Read-only
Processor Port BIOS Connector Type
Name
processorPortBIOSConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.30.1.9
Description
Defines the BIOS connector type of the processor port.
Syntax
DellGenericPortConnectorType
Access
Read-only
Port Group
189
Memory Device Port Table
Name
memoryDevicePortTable
Object ID
1.3.6.1.4.1.674.10892.1.1000.40
Description
Defines the Memory Device Port Table.
Syntax
IntegerMemoryDevicePortTableEntry
Access
Not accessible
Memory Device Port Table Entry
Name
memoryDevicePortTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1000.40.1
Description
Defines the Memory Device Port Table entry.
Syntax
MemoryDevicePortTableEntry
Access
Not accessible
Index
memoryDevicePortchassisIndex, memoryDevicePortIndex
Memory Device Port Chassis Index
Name
memoryDevicePortchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.40.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Memory Device Port Index
190
Name
memoryDevicePortIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.40.1.2
Description
Defines the index of the memory device port in this chassis.
Syntax
DellObjectRange
Access
Read-only
Port Group
Memory Device Port State Capabilities
Name
memoryDevicePortStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1000.40.1.3
Description
Defines the capabilities of the memory device port.
Syntax
DellStateCapabilities
Access
Read-only
Memory Device Port State Settings
Name
memoryDevicePortStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1000.40.1.4
Description
Defines the state and settings of the memory device port.
Syntax
DellStateSettings
Access
Read-write
Memory Device Port Status
Name
memoryDevicePortStatus
Object ID
1.3.6.1.4.1.674.10892.1.1000.40.1.5
Description
Defines the status of the memory device port.
Syntax
DellStatus
Access
Read-only
Memory Device Port Security State
Name
memoryDevicePortSecurityState
Object ID
1.3.6.1.4.1.674.10892.1.1000.40.1.6
Description
Defines the security settings of the memory device port.
Syntax
DellPortSecurityState
Access
Read-only
Port Group
191
Memory Device Port Connector Type
Name
memoryDevicePortConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.40.1.7
Description
Defines the connector type of the memory device port.
Syntax
DellMemoryDevicePortConnectorType (See Table 12-4.)
Access
Read-only
Memory Device Port Name
Name
memoryDevicePortName
Object ID
1.3.6.1.4.1.674.10892.1.1000.40.1.8
Description
Defines the name of the memory device port.
Syntax
DellString
Access
Read-only
Memory Device Port BIOS Connector Type
Name
memoryDevicePortBIOSConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.40.1.9
Description
Defines the BIOS connector type of the memory device port.
Syntax
DellGenericPortConnectorType
Access
Read-only
Memory Device Port Physical Memory Array Index Reference
192
Name
memoryDevicePortPhysicalMemoryArrayIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1000.40.1.10
Description
Defines the index to the associated physical memory array.
Syntax
DellUnsigned32BitRange
Access
Read-only
Port Group
Memory Device Port Physical Memory Card Index Reference
Name
memoryDevicePortPhysicalMemoryCardIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1000.40.1.11
Description
Defines the index (one-based) of the Physical Memory Card Table
entry for the physical memory card with the same chassis index that
this memory device port is associated with (if any).
Syntax
DellUnsigned32BitRange
Access
Read-only
Monitor Port Table
Name
monitorPortTable
Object ID
1.3.6.1.4.1.674.10892.1.1000.50
Description
Defines the Monitor Port Table.
Syntax
IntegerMonitorPortTableEntry
Access
Not accessible
Monitor Port Table Entry
Name
monitorPortTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1000.50.1
Description
Defines the Monitor Port Table entry.
Syntax
MonitorPortTableEntry
Access
Not accessible
Index
monitorPortchassisIndex, monitorPortIndex
Monitor Port Chassis Index
Name
monitorPortchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.50.1.1
Description
Defines the index (one-based) of this chassis
Syntax
DellObjectRange
Access
Read-only
Port Group
193
Monitor Port Index
Name
monitorPortIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.50.1.2
Description
Defines the index of the monitor ports in this chassis.
Syntax
DellObjectRange
Access
Read-only
Monitor Port State Capabilities
Name
monitorPortStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1000.50.1.3
Description
Defines the capabilities of the monitor port.
Syntax
DellStateCapabilities
Access
Read-only
Monitor Port State Settings
Name
monitorPortStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1000.50.1.4
Description
Defines the state of the monitor port.
Syntax
DellStateSettings
Access
Read-write
Monitor Port Status
194
Name
monitorPortStatus
Object ID
1.3.6.1.4.1.674.10892.1.1000.50.1.5
Description
Defines the status of the monitor port.
Syntax
DellStatus
Access
Read-only
Port Group
Monitor Port Security State
Name
monitorPortSecurityState
Object ID
1.3.6.1.4.1.674.10892.1.1000.50.1.6
Description
Defines the security settings of the monitor port.
Syntax
DellPortSecurityState
Access
Read-only
Monitor Port Connector Type
Name
monitorPortConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.50.1.7
Description
Defines the connector type of the monitor port.
Syntax
DellMonitorPortConnectorTypes (See Table 12-5.)
Access
Read-only
Monitor Port Name
Name
monitorPortName
Object ID
1.3.6.1.4.1.674.10892.1.1000.50.1.8
Description
Defines the name of the monitor port.
Syntax
DellString
Access
Read-only
Monitor Port BIOS Connector Type
Name
monitorPortBIOSConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.50.1.9
Description
Defines the name of the BIOS connector type of the monitor port.
Syntax
DellGenericPortConnectorType
Access
Read-only
Port Group
195
Small Computer System Interface (SCSI) Port Table
Name
sCSIPortTable
Object ID
1.3.6.1.4.1.674.10892.1.1000.60
Description
Defines the SCSI Port Table.
Syntax
IntegerSCSIPortTableEntry
Access
Not accessible
SCSI Port Table Entry
Name
sCSIPortTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1000.60.1
Description
Defines the SCSI Port Table entry.
Syntax
SCSIPortTableEntry
Access
Not accessible
Index
sCSIPortchassisIndex, sCSIPortIndex
SCSI Port Chassis Index
Name
sCSIPortchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.60.1.1
Description
Defines the index (one-based) of this chassis
Syntax
DellObjectRange
Access
Read-only
SCSI Port Index
196
Name
sCSIPortIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.60.1.2
Description
Defines the index of the SCSI ports in this chassis.
Syntax
DellObjectRange
Access
Read-only
Port Group
SCSI Port State Capabilities
Name
sCSIPortStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1000.60.1.3
Description
Defines the capabilities of the SCSI port.
Syntax
DellStateCapabilities
Access
Read-only
SCSI Port State Settings
Name
DellStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1000.60.1.4
Description
Defines the state and settings of the SCSI port.
Syntax
DellStatus
Access
Read-write
SCSI Port Status
Name
sCSIPortStatus
Object ID
1.3.6.1.4.1.674.10892.1.1000.60.1.5
Description
Defines the status of the SCSI port.
Syntax
DellStatus
Access
Read-only
SCSI Port Security State
Name
sCSIPortSecurityState
Object ID
1.3.6.1.4.1.674.10892.1.1000.60.1.6
Description
Defines the security settings of the SCSI port.
Syntax
DellPortSecurityState
Access
Read-only
Port Group
197
SCSI Port Connector Type
Name
sCSIPortConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.60.1.7
Description
Defines the connector type of the SCSI port.
Syntax
DellSCSIPortConnectorType (See Table 12-6.)
Access
Read-only
SCSI Port Name
Name
sCSIPortName
Object ID
1.3.6.1.4.1.674.10892.1.1000.60.1.8
Description
Defines the name of the SCSI port.
Syntax
DellString
Access
Read-only
SCSI Port BIOS Connector Type
Name
sCSIPortBIOSConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.60.1.9
Description
Defines the BIOS connector type of the SCSI port.
Syntax
DellGenericPortConnectorType
Access
Read-only
Parallel Port Table
198
Name
parallelPortTable
Object ID
1.3.6.1.4.1.674.10892.1.1000.70
Description
Defines the Parallel Port Table.
Syntax
IntegerParallelPortTableEntry
Access
Not accessible
Port Group
Parallel Port Table Entry
Name
parallelPortTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1
Description
Defines the Parallel Port Table entry.
Syntax
ParallelPortTableEntry
Access
Not accessible
Index
parallelPortchassisIndex, parallelPortIndex
Parallel Port Chassis Index
Name
parallelPortchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Parallel Port Index
Name
parallelPortIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1.2
Description
Defines the index of the parallel ports in this chassis.
Syntax
DellObjectRange
Access
Read-only
Parallel Port State Capabilities
Name
parallelPortStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1.3
Description
Defines the capabilities of the parallel port.
Syntax
DellStateSettings
Access
Read-write
Port Group
199
Parallel Port State Settings
Name
parallelPortStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1.4
Description
Defines the state and settings of the parallel port.
Syntax
DellStateSettings
Access
Read-write
Parallel Port Status
Name
parallelPortStatus
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1.5
Description
Defines the status of the parallel port.
Syntax
DellStatus
Access
Read-only
Parallel Port Security State
Name
DellPortSecurityState
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1.6
Description
Defines the security state of the parallel port.
Syntax
DellStatus
Access
Read-only
Parallel Port Connector Type
200
Name
parallelPortConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1.7
Description
Defines the connector type of the parallel port.
Syntax
DellParallelPortConnectorType
Access
Read-only
Port Group
Parallel Port Name
Name
parallelPortName
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1.8
Description
Defines the name of the parallel port.
Syntax
DellString
Access
Read-only
Parallel Port Connector Pin Out
Name
parallelPortConnectorPinOut
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1.9
Description
Defines the pinout of the parallel port.
Syntax
DellParallelPortConnectorPinout
Access
Read-only
Parallel Port Capabilities Unique
Name
parallelPortCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1.10
Description
Defines the capabilities of the parallel port.
Syntax
DellParallelPortConnectorPinout
Access
Read-only
Parallel Port Base I/O Address
Name
parallelPortBaseIOAddress
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1.11
Description
Defines the Base Input/Output (I/O) address of the parallel port.
Syntax
DellUnsigned64BitRange
Access
Read-only
Port Group
201
Parallel Port IRQ Level
Name
parallelPortIRQLevel
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1.12
Description
Defines the Interrupt Request Level (IRQ) of the parallel port.
Syntax
DellUnsigned8BitRange
Access
Read-only
Parallel Port DMA Support
Name
parallelPortDMASupport
Object ID
1.3.6.1.4.1.674.10892.1.1000.70.1.13
Description
Defines if direct memory access (DMA) is supported by the
parallel port.
Syntax
DellBoolean
Access
Read-only
Serial Port Table
Name
serialPortTable
Object ID
1.3.6.1.4.1.674.10892.1.1000.80
Description
Defines the Serial Port Table.
Syntax
IntegerSerialPortTableEntry
Access
Not accessible
Serial Port Table Entry
202
Name
serialPortTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1000.80.1
Description
Defines the Serial Port Table entry.
Syntax
SerialPortTableEntry
Access
Not accessible
Port Group
Serial Port Chassis Index
Name
serialPortchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.80.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Serial Port Index
Name
serialPortIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.80.1.2
Description
Defines the index of the serial ports in this chassis.
Syntax
DellObjectRange
Access
Read-only
Serial Port State Capabilities
Name
serialPortStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1000.80.1.3
Description
Defines the capabilities of the serial port.
Syntax
DellStateCapabilities
Access
Read-only
Serial Port State Settings
Name
serialPortStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1000.80.1.4
Description
Defines the state and settings of the serial port.
Syntax
DellStateSettings
Access
Read-write
Port Group
203
Serial Port Status
Name
serialPortStatus
Object ID
1.3.6.1.4.1.674.10892.1.1000.80.1.5
Description
Defines the status of the serial port.
Syntax
DellStatus
Access
Read-only
Serial Port Security State
Name
serialPortSecurityState
Object ID
1.3.6.1.4.1.674.10892.1.1000.80.1.6
Description
Defines the security settings of the serial port.
Syntax
DellPortSecurityState
Access
Read-only
Serial Port Connector Type
Name
serialPortConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.80.1.7
Description
Defines connector type of the serial port.
Syntax
DellSerialPortConnectorType
Access
Read-only
Serial Port Name
204
Name
serialPortName
Object ID
1.3.6.1.4.1.674.10892.1.1000.80.1.8
Description
Defines the name of the serial port.
Syntax
DellString
Access
Read-only
Port Group
Serial Port Maximum Speed
Name
serialPortMaximumSpeed
Object ID
1.3.6.1.4.1.674.10892.1.1000.80.1.9
Description
Defines the maximum speed the serial interface can support in
bits per second (bps).
Syntax
DellUnsigned32BitRange
Access
Read-only
Serial Port Capabilities Unique
Name
serialPortCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1000.80.1.10
Description
Defines additional capabilities of the serial port.
Syntax
DellSerialPortCapabilitiesUnique
Access
Read-only
Serial Port Base I/O Address
Name
serialPortBaseIOAddress
Object ID
1.3.6.1.4.1.674.10892.1.1000.80.1.11
Description
Defines the base I/O address of the serial port.
Syntax
DellUnsigned64BitRange
Access
Read-only
Serial Port IRQ Level
Name
serialPortIRQLevel
Object ID
1.3.6.1.4.1.674.10892.1.1000.80.1.12
Description
Defines the IRQ of the serial port.
Syntax
DellUnsigned8BitRange
Access
Read-only
Port Group
205
Universal Serial Bus (USB) Port Table
Name
uSBPortTable
Object ID
1.3.6.1.4.1.674.10892.1.1000.90
Description
Defines the USB Port Table.
Syntax
IntegerUSBPortTableEntry
Access
Not accessible
USB Port Table Entry
Name
uSBPortTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1000.90.1
Description
Defines the USB Port Table entry.
Syntax
USBPortTableEntry
Access
Not accessible
Index
pointingPortchassisIndex, pointingPortIndex
USB Port Chassis Index
Name
uSBPortchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.90.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
USB Port Index
206
Name
uSBPortIndex
Object ID
1.3.6.1.4.1.674.10892.1.1000.90.1.2
Description
Defines the index of the USB ports in this chassis
Syntax
DellObjectRange
Access
Read-only
Port Group
USB Port State Capabilities
Name
uSBPortStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1000.90.1.3
Description
Defines the capabilities of the USB port.
Syntax
DellStateCapabilities
Access
Read-only
USB Port State Settings
Name
uSBPortStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1000.90.1.4
Description
Defines the state and settings of the USB port.
Syntax
DellStateSettings
Access
Read-write
USB Port Status
Name
uSBPortStatus
Object ID
1.3.6.1.4.1.674.10892.1.1000.90.1.5
Description
Defines the state of the USB port.
Syntax
DellStatus
Access
Read-only
USB Port Security State
Name
uSBPortSecurityState
Object ID
1.3.6.1.4.1.674.10892.1.1000.90.1.6
Description
Defines the security settings of the USB port.
Syntax
DellPortSecurityState
Access
Read-only
Port Group
207
USB Port Connector Type
Name
uSBPortConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.90.1.7
Description
Defines the connector type of the USB port.
Syntax
DellUSBPortConnectorType
Access
Read-only
USB Port Name
Name
uSBPortName
Object ID
1.3.6.1.4.1.674.10892.1.1000.90.1.8
Description
Defines the name of the USB port.
Syntax
DellString
Access
Read-only
USB Port BIOS Connector Type
208
Name
uSBPortBIOSConnectorType
Object ID
1.3.6.1.4.1.674.10892.1.1000.90.1.9
Description
Defines the BIOS connector type of the USB port.
Syntax
DellGenericPortConnectorType
Access
Read-only
Port Group
Port Group Variable Values
This section includes definitions for server administrator-specific variable values used in this section.
Table 12-1.
Pointing Port Connector Type
Variable Name: DellPointingPortConnectorType
Data Type: Integer
Possible Data Values
Meaning of Data Value
connectorPortTypeIsOther(1)
The pointing port connector type is not one of the following:
connectorPortTypeIsUnknown(2)
The pointing port connector type is unknown.
connectorPortTypeIsSerial(3)
The pointing port connector type is serial.
connectorPortTypeIsPS2(4)
The pointing port connector type is a Personal System/2 (PS/2).
connectorPortTypeIsInfrared(5)
The pointing port connector type is infrared.
connectorPortTypeIsHPHIL(6)
The pointing port connector type is HP-HIL.
connectorPortTypeIsBusMouse(7)
The pointing port connector type is a bus mouse.
connectorPortTypeIsADB(8)
The pointing port connector type is ADB.
connectorPortTypeIsDB9(9)
The pointing port connector type is nine-pin DB-9.
connectorPortTypeIsMicroDIN(10)
The pointing port connector type is micro Deutsche Industrie
Norm (DIN).
connectorPortTypeIsAccessBusUSB(11) The pointing port connector type is Access Bus USB.
connectorPortTypeIsPC98(12)
The port connector type is a PC-98.
Port Group
209
Table 12-2.
Keyboard Port Connector Types
Variable Name: DellKeyboardPortConnectorType
Data Type: Integer
Possible Data Values
Meaning of Data Value
connectorPortTypeIsOther(1)
The keyboard port connector type is not one of the following:
connectorPortTypeIsUnknown(2)
The keyboard port connector type is unknown.
connectorPortTypeIsMiniDIN(3)
The keyboard port connector type is a mini DIN.
connectorPortTypeIsMicroDIN(4)
The keyboard port connector type is a MicroDIN.
connectorPortTypeIsPS2(5)
The keyboard port connector type is PS/2.
connectorPortTypeIsInfrared(6)
The keyboard port connector type is infrared.
connectorPortTypeIsHPHIL(7)
The keyboard port connector type is HP-HIL.
connectorPortTypeIsDB9(8)
The keyboard port connector type is DB-9.
connectorPortTypeIsAccessBusUSB(9) The keyboard port connector type is bus USB.
connectorPortTypeIsPC98(10)
Table 12-3.
The keyboard port connector type is PC-98.
Processor Port Connector Types
Variable Name: DellProcessorPortConnectorType
Data Type: Integer
Possible Data Values
Meaning of Data Value
connectorPortTypeIsOther(1)
The processor port connector type is not one of the following:
connectorPortTypeIsUnknown(2)
The processor port connector type is unknown.
connectorPortTypeIsDaughterdBoard(3) The processor port connector type is a daughter board.
connectorPortTypeIsZIFSocket(4)
The processor port connector type is a zero insertion force (ZIF)
socket.
connectorPortTypeIsAPiggyBackBoard(5) The processor port connector type is a replacement piggyback board.
connectorPortTypeIsNone(6)
There is no processor port connector; processor is soldered in place.
connectorPortTypeIsLIFSocket(7)
The processor port connector type is a low insertion force (LIF) socket.
connectorPortTypeIsSlot1(8)
The processor port connector type is a slot one.
connectorPortTypeIsSlot2(9)
The processor port connector type is a slot two.
connectorPortTypeIs370PinSocket(10) The processor port connector type is a 370 pin socket.
210
Port Group
Table 12-4.
Memory Device Port Connector Types
Variable Name: DellMemoryDevicePortConnectorType
Data Type: Integer
Possible Data Value
Meaning of Data Value
connectorPortTypeIsOther(1)
The memory device port connector type is not one of the
following:
connectorPortTypeIsUnknown(2)
The memory device port connector type is unknown.
connectorPortTypeIsSIMM(3)
The memory device port connector type is a single in-line
memory module (SIMM).
connectorPortTypeIsSIP(4)
The memory device port connector type is a SIP.
connectorPortTypeIsAChip(5)
The memory device port connector type is a chip.
connectorPortTypeIsDIP(6)
The memory device port connector type is a dual in-line
package (DIP).
connectorPortTypeIsZIP(7)
The memory device port connector type is a ZIP.
connectorPortTypeIsAProprietaryCard(8) The memory device port connector type is a
proprietary card.
connectorPortTypeIsDIMM(9)
The memory device port connector type is a dual in-line
memory module (DIMM).
connectorPortTypeIsTSOP(10)
The memory device port connector type is a TSOP.
connectorPortTypeIsARowOfChips(11)
The memory device port connector type is a row of chips.
connectorPortTypeIsRIMM(12)
The memory device port connector type is a Rambus Inline
Memory Module (RIMM).
connectorPortTypeIsSODIMM(13)
The memory device port connector type is a small outline,
dual in-line memory module (SODIMM).
connectorPortTypeIsSRIMM(14)
The memory device port connector type is a SRIMM.
Port Group
211
Table 12-5.
Monitor Port Connector Types
Variable Name: DellMonitorPortConnectorType
Data Type: Integer
Possible Data Values
Meaning of Data Value
connectorPortTypeIsOther(1)
The monitor port connector type is not one of the following:
connectorPortTypeIsUnknown(2)
The monitor port connector type is unknown.
connectorPortTypeIsDB15PinMale(3)
The monitor port connector type is a male DB-15.
connectorPortTypeIsDB15PinFemale(4) The monitor port connector type is a female DB-15.
Table 12-6.
SCSI Port Connector Types
Variable Name: DellSCSIPortConnectorType
Data Type: Integer
212
Possible Data Values
Meaning of Data Value
connectorPortTypeIsOther(1)
The SCSI port connector type is not one of the following:
connectorPortTypeIsUnknown(2)
The SCSI port connector type is unknown.
connectorPortTypeIsDIN25pin(3)
The SCSI port connector type is a DIN 25-pin.
connectorPortTypeIsDIN50pin(4)
The SCSI port connector type is a DIN 50-pin.
connectorPortTypeIsDIN68pin(5)
The SCSI port connector type is a DIN 68-pin.
Port Group
Device Group
The Device Group provides information about different types of pointing, keyboard, processor,
cache, memory, and peripheral component interconnect (PCI) devices. Variables in this group cover
information about type, settings, configuration, manufacturer, address or location, and if applicable,
the speed of the device.
Device Tables
The following management information base (MIB) tables define objects in the Device Group:
•
Pointing Device Table
•
Keyboard Device Table
•
Processor Device Table
•
Processor Device Status Table
•
Cache Device Table
•
Memory Device Table
•
Memory Device Mapped Address Table
•
Generic Device Table
•
PCI Device Table
•
PCI Device Configuration Space Table
•
Network Device Table
Pointing Device Table
Name
pointingDeviceTable
Object ID
1.3.6.1.4.1.674.10892.1.1100.10
Description
Defines the Pointing Device Table. This group of objects references
the Pointing Port Index (See Section 12).
Syntax
SEQUENCE OF PointingDeviceTableEntry
Access
Not accessible
Device Group
213
Pointing Device Table Entry
Name
pointingDeviceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1100.10.1
Description
Defines the Pointing Device Table entry.
Syntax
PointingDeviceTableEntry
Access
Not accessible
Index
pointingDevicechassisIndex, pointingDeviceIndex
Pointing Device Chassis Index
Name
pointingDevicechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.10.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Pointing Device Index
Name
pointingDeviceIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.10.1.2
Description
Defines the index of the pointing device in this chassis.
Syntax
DellObjectRange
Access
Read-only
Pointing Device State Capabilities
214
Name
pointingDeviceStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1100.10.1.3
Description
Defines the capabilities of the pointing device.
Syntax
DellStateCapabilities
Access
Read-only
Device Group
Pointing Device State Settings
Name
pointingDeviceStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1100.10.1.4
Description
Defines the state of the pointing device.
Syntax
DellStateSettings
Access
Read-write
Pointing Device Status
Name
pointingDeviceStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.10.1.5
Description
Defines the status of the pointing device.
Syntax
DellStatus
Access
Read-only
Pointing Port Index Reference
Name
pointingPortIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1100.10.1.6
Description
Defines the index to the pointing port in this chassis.
Syntax
DellObjectRange
Access
Read-only
Pointing Device Type
Name
pointingDeviceType
Object ID
1.3.6.1.4.1.674.10892.1.1100.10.1.7
Description
Defines the type of the pointing device.
Syntax
DellPointingDeviceType (See Table 13-1.)
Access
Read-only
Device Group
215
Pointing Device Number of Buttons
Name
pointingDeviceNumberofButtons
Object ID
1.3.6.1.4.1.674.10892.1.1100.10.1.8
Description
Defines the number of buttons on the pointing device.
Syntax
DellUnsigned8BitRange
Access
Read-only
Keyboard Device Table
Name
keyboardDeviceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1100.20
Description
Defines the Keyboard Device Table. This table references the
Keyboard Port Index (See Section 12).
Syntax
SEQUENCE OF KeyboardDeviceTableEntry
Access
Not accessible
Keyboard Device Table Entry
Name
keyboardDeviceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1100.20.1
Description
Defines the Keyboard Device Table entry.
Syntax
KeyboardDeviceTableEntry
Access
Not accessible
Index
keyboardDevicechassisIndex, keyboardDeviceIndex
Keyboard Device Chassis Index
216
Name
keyboardDevicechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.20.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Device Group
Keyboard Device Index
Name
keyboardDeviceIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.20.1.2
Description
Defines the index of the keyboard device for this chassis.
Syntax
DellObjectRange
Access
Read-only
Keyboard Device State Capabilities
Name
keyboardDeviceStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1100.20.1.3
Description
Defines the capabilities of the keyboard device.
Syntax
DellStateCapabilities
Access
Read-only
Keyboard Device State Settings
Name
keyboardDeviceStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1100.20.1.4
Description
Defines the state of the keyboard device.
Syntax
DellStatesSettings
Access
Read-write
Keyboard Device Status
Name
keyboardDeviceStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.20.1.5
Description
Defines the status of the keyboard device.
Syntax
DellStatus
Access
Read-only
Device Group
217
Keyboard Port Index Reference
Name
keyboardPortIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1100.20.1.6
Description
Defines the index to the associated the keyboard port in this chassis.
Syntax
DellStatus
Access
Read-only
Keyboard Device Type Name
Name
keyboardDeviceTypeName
Object ID
1.3.6.1.4.1.674.10892.1.1100.20.1.7
Description
Defines the name of the keyboard type.
Syntax
DellString
Access
Read-only
Keyboard Device Layout Name
Name
keyboardDeviceLayoutName
Object ID
1.3.6.1.4.1.674.10892.1.1100.20.1.8
Description
Defines the name of the keyboard layout.
Syntax
DellString
Access
Read-only
Processor Device Table
218
Name
processorDeviceTable
Object ID
1.3.6.1.4.1.674.10892.1.1100.30
Description
Defines the Processor Device Table.
Syntax
SEQUENCE OF ProcessorDeviceTableEntry
Access
Not accessible
Device Group
Processor Device Table Entry
Name
processorDeviceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1
Description
Defines the Processor Device Table entry.
Syntax
ProcessorDeviceTableEntry
Access
Not accessible
Index
processorDevicechassisIndex, processorDeviceIndex
Processor Device Chassis Index
Name
processorDevicechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Processor Device Index
Name
processorDeviceIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.2
Description
Defines the index of the processor device in this chassis.
Syntax
DellObjectRange
Access
Read-only
Processor Device State Capabilities
Name
processorDeviceStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.3
Description
Defines the capabilities of the processor device.
Syntax
DellStateCapabilities
Access
Read-only
Device Group
219
Processor Device State Settings
Name
processorDeviceStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.4
Description
Defines the state of the processor device.
Syntax
DellStateSettings
Access
Read-write
Processor Device Status
Name
processorDeviceStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.5
Description
Defines the status of the processor device.
Syntax
DellStatus
Access
Read-only
Processor Port Index Reference
Name
processorPortIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.6
Description
Defines the index to the associated processor port in this chassis.
Syntax
DellObjectRange
Access
Read-only
Processor Device Type
220
Name
processorDeviceType
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.7
Description
Defines the type of processor device.
Syntax
DellProcessorDeviceType (See Table 13-4)
Access
Read-only
Device Group
Processor Device Manufacturer Name
Name
processorDeviceManufacturerName
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.8
Description
Defines the name of manufacturer of the processor device.
Syntax
DellString
Access
Read-only
Processor Device Status State
Name
processorDeviceStatusState
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.9
Description
Defines the status state of the processor device.
Syntax
DellProcessorDeviceStatusState (See Table 13-2.)
Access
Read-only
Processor Device Family
Name
processorDeviceFamily
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.10
Description
Defines the family of the processor device.
Syntax
DellProcessorDeviceFamily (See Table 13-6.)
Access
Read-only
Processor Device Maximum Speed
Name
processorDeviceMaximumSpeed
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.11
Description
Defines the maximum speed of the processor device in megahertz (MHz).
A zero (0) indicates that the speed is unknown.
Syntax
DellUnsigned32BitRange
Access
Read-only
Device Group
221
Processor Device Current Speed
Name
processorDeviceCurrentSpeed
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.12
Description
Defines the current speed of the processor device in MHz. A zero (0)
indicates that the speed is unknown.
Syntax
DellUnsigned32BitRange
Access
Read-only
Processor Device External Clock Speed
Name
processorDeviceExternalClockSpeed
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.13
Description
Defines the speed of the external clock (the front-side bus speed)
for the processor device in MHz. A zero (0) indicates that the
speed is unknown.
Syntax
DellUnsigned32BitRange
Access
Read-only
Processor Device Voltage
Name
processorDeviceVoltage
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.14
Description
Defines the voltage powering the processor device in millivolts.
A zero (0) indicates the speed is unknown.
Syntax
DellSigned32BitRange
Access
Read-only
Processor Device Upgrade Information
222
Name
processorDeviceUpgradeInformation
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.15
Description
Defines the processor upgrade information for the processor device.
Syntax
DellProcessorUpgradeInformation (See Table 13-5.)
Access
Read-only
Device Group
Processor Device Version Name
Name
processorDeviceVersionName
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.16
Description
Defines the version name of the processor device.
Syntax
DellString
Access
Read-only
Processor Device Core Count
Name
processorDeviceCoreCount
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.17
Description
Defines the number of processor cores detected for the
processor device.
Syntax
DellUnsigned32BitRange
Access
Read-only
Processor Device Core Enabled Count
Name
processorDeviceCoreEnabledCount
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.18
Description
Defines the number of processor cores enabled for the
processor device.
Syntax
DellUnsigned32BitRange
Access
Read-only
Processor Device Thread Count
Name
processorDeviceThreadCount
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.19
Description
Defines the number of processor threads detected for the
processor device.
Syntax
DellUnsigned32BitRange
Access
Read-only
Device Group
223
Processor Device Characteristics
Name
processorDeviceCharacteristics
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.20
Description
This attribute defines characteristics of the processor device. This
attribute is a bit field where a bit has the meaning defined below
when set to 1 (one).
NOTE: Bits 2-15 need to be examined in the context of bit 1. If bit 1 is set,
the processor characteristics are unknown and bits 2-15 cannot be
used to determine if the functions associated with the bits are
supported.
Bit Position
-------------Bit 0
Bit 1
Bit 2
Bit 3-15
Meaning if Set
-----------------Reserved
Unknown
64-bit capable
Reserved
Syntax
DellUnsigned16BitRange
Access
Read-only
Processor Device Extended Capabilities
Name
processorDeviceExtendedCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.21
Description
This attribute defines extended capabilities of the processor device.
This attribute is a bit field where a bit has the meaning defined
below when set to 1 (one).
Bit Position
--------------Bit 0
Bit 1
Bit 2
Bit 3
224
Meaning if Set
-------------Virtualization Technology (VT) supported
Demand-Based Switching (DBS) supported
eXecute Disable (XD) supported
Hyper-Threading (HT) supported
Syntax
DellUnsigned16BitRange
Access
Read-only
Device Group
Processor Device Extended Settings
Name
processorDeviceExtendedSettings
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.22
Description
This attribute defines extended settings of the processor device. This
attribute is a bit field where a bit has the meaning defined below
when set to 1 (one).
Bit Position
--------------Bit 0
Bit 1
Bit 2
Bit 3
Meaning if Set
------------Virtualization Technology (VT) enabled
Demand Based Switching (DBS) enabled
eXecute Disable (XD) enabled
Hyper-Threading (HT) enabled
Syntax
DellUnsigned16BitRange
Access
Read-only
Processor Device Brand Name
Name
processorDeviceBrandName
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.23
Description
Defines the brand of the processor device.
Syntax
DellString
Access
Read-only
Processor Device Model Name
Name
processorDeviceModelName
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.24
Description
Defines the model of the processor device.
Syntax
DellString
Access
Read-only
Device Group
225
Processor Device Stepping Name
Name
processorDeviceSteppingName
Object ID
1.3.6.1.4.1.674.10892.1.1100.30.1.25
Description
Defines the stepping of the processor device.
Syntax
DellString
Access
Read-only
Processor Device Status Table
Name
processorDeviceStatusTable
Object ID
1.3.6.1.4.1.674.10892.1.1100.32
Description
Defines the Processor Device Status Table.
Syntax
SEQUENCE OF ProcessorDeviceStatusTableEntry
Access
Not accessible
Processor Device Status Table Entry
Name
processorDeviceStatusTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1100.32.1
Description
Defines the Processor Device Status Table Entry.
Syntax
ProcessorDeviceStatusTableEntry
Access
Not accessible
Index
processorDeviceStatusChassisIndex, processorDeviceStatusIndex
Processor Device Status Chassis Index
226
Name
processorDeviceStatusChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.32.1.1
Description
Defines the index (one-based) of the associated chassis.
Syntax
DellObjectRange
Access
Read-only
Device Group
Processor Device Status Index
Name
processorDeviceStatusIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.32.1.2
Description
Defines the index (one-based) of the processor device status probe.
Syntax
DellObjectRange
Access
Read-only
Processor Device Status State Capabilities
Name
processorDeviceStatusStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1100.32.1.3
Description
Defines the state capabilities of the processor device status probe.
Syntax
DellStateCapabilities
Access
Read-only
Processor Device Status State Settings
Name
processorDeviceStatusStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1100.32.1.4
Description
Defines the state settings of the processor device status probe.
Syntax
DellStateSettings
Access
Read-write
Processor Device Status Status
Name
processorDeviceStatusStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.32.1.5
Description
Defines the status of the processor device status probe. This status
will be joined into the processorDeviceStatus attribute.
Syntax
DellStatus
Access
Read-only
Device Group
227
Processor Device Status Reading
Name
processorDeviceStatusReading
Object ID
1.3.6.1.4.1.674.10892.1.1100.32.1.6
Description
Defines the reading of the processor device status probe.
Syntax
DellProcessorDeviceStatusReading
Access
Read-only
Processor Device Status Location Name
Name
processorDeviceStatusLocationName
Object ID
1.3.6.1.4.1.674.10892.1.1100.32.1.7
Description
Defines the location name of the processor device status probe.
Syntax
DellString
Access
Read-only
Processor Device Status Port Index Reference
Name
processorDeviceStatusPortIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1100.32.1.8
Description
Defines the index (one-based) of the associated processor port in the
same chassis.
Syntax
DellObjectRange
Access
Read-only
Cache Device Table
228
Name
cacheDeviceTable
Object ID
1.3.6.1.4.1.674.10892.1.1100.40
Description
Defines the Cache Device Table.
Syntax
SEQUENCE OF CacheDeviceTableEntry
Access
Not accessible
Device Group
Cache Device Table Entry
Name
cacheDeviceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1
Description
Defines the Cache Device Table entry.
Syntax
CacheDeviceTableEntry
Access
Not accessible
Index
cacheDevicechassisIndex, cacheDeviceIndex
Cache Device Chassis Index
Name
cacheDevicechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Cache Device Index
Name
cacheDeviceIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.2
Description
Defines the index of the cache device in this chassis.
Syntax
DellObjectRange
Access
Read-only
Cache Device State Capabilities
Name
cacheDeviceStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.3
Description
Defines the capabilities of the cache device.
Syntax
DellStateCapabilities
Access
Read-only
Device Group
229
Cache Device State Settings
Name
cacheDeviceStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.4
Description
Defines the state of the cache device.
Syntax
DellStateSettings
Access
Read-write
Cache Device Status
Name
cacheDeviceStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.5
Description
Defines the status of the cache device.
Syntax
DellStatus
Access
Read-only
Cache Device Processor Device Index Reference
Name
cacheDeviceprocessorDeviceIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.6
Description
Defines the index number of the processor device with which this
cache device is associated.
Syntax
DellObjectRange
Access
Read-only
Cache Device Type
230
Name
cacheDeviceType
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.7
Description
Defines the type of cache device.
Syntax
DellCacheDeviceType (See Table 13-7.)
Access
Read-only
Device Group
Cache Device Location
Name
cacheDeviceLocation
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.8
Description
Defines the location of the cache device.
Syntax
DellCacheDeviceLocation (See Table 13-13.)
Access
Read-only
Cache Device Status State
Name
cacheDeviceStatusState
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.9
Description
Defines the status state of the cache device.
Syntax
DellCacheDeviceStatusState (See Table 13-10.)
Access
Read-only
Cache Device External Socket Name
Name
cacheDeviceExternalSocketName
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.10
Description
Defines the external socket name of the cache device, if the cache
is socketed.
Syntax
DellString
Access
Read-only
Cache Device Level
Name
cacheDeviceLevel
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.11
Description
Defines the level of the cache device.
Syntax
DellCacheDeviceLevel (See Table 13-8)
Access
Read-only
Device Group
231
Cache Device Maximum Size
Name
cacheDeviceMaximumSize
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.12
Description
Defines the maximum size of the cache device in kilobytes (KB).
A zero (0) indicates that the size is unknown.
Syntax
DellUnsigned32BitRange
Access
Read-only
Cache Device Current Size
Name
cacheDeviceCurrentSize
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.13
Description
Defines the current size of the cache device in KB. A zero (0)
indicates that the size is unknown.
Syntax
DellUnsigned32BitRange
Access
Read-only
Cache Device Speed
Name
cacheDeviceSpeed
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.14
Description
Defines the speed of the cache device in nanoseconds. A zero (0)
indicates that the speed is unknown.
Syntax
DellUnsigned32BitRange
Access
Read-only
Cache Device Write Policy
232
Name
cacheDeviceWritePolicy
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.15
Description
Defines the write policy of the cache device.
Syntax
DellCacheDeviceWritePolicy (See Table 13-9.)
Access
Read-only
Device Group
Cache Device Is Socketed
Name
cacheDeviceIsSocketed
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.16
Description
Defines if the cache device is socketed.
Syntax
DellBoolean
Access
Read-only
Cache Device Error Checking and Correction (ECC) Type
Name
cacheDeviceECCType
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.17
Description
Defines the type of error correction in use by the cache device.
Syntax
DellCacheDeviceECCType (See Table 13-11.)
Access
Read-only
Cache Device Associativity
Name
cacheDeviceAssociativity
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.18
Description
Defines the type of associativity in use by the cache device.
Syntax
DellCacheDeviceAssociativity (See Table 13-12.)
Access
Read-only
Cache Device Supported Type
Name
cacheDeviceSupportedType
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.19
Description
Defines the type of static random-access memory (SRAM) that the
cache device can support.
Syntax
DellCacheDeviceSupportedType
Access
Read-only
Device Group
233
Cache Device Current Type
Name
cacheDeviceCurrentType
Object ID
1.3.6.1.4.1.674.10892.1.1100.40.1.20
Description
Defines the current type of SRAM for the cache device.
Syntax
DellCacheDeviceSRAMType (See Table 13-14.)
Access
Read-only
Memory Device Table
Name
memoryDeviceTable
Object ID
1.3.6.1.4.1.674.10892.1.1100.50
Description
Defines the Memory Device Table.
Syntax
SEQUENCE OF MemoryDeviceTableEntry
Access
Not accessible
Memory Device Table Entry
Name
memoryDeviceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1
Description
Defines the Memory Device Table entry.
Syntax
MemoryDeviceTableEntry
Access
Not accessible
Index
memoryDevicechassisIndex, memoryDeviceIndex
Memory Device Chassis Index
234
Name
memoryDevicechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Device Group
Memory Device Index
Name
memoryDeviceIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.2
Description
Defines the index of the memory device in this chassis.
Syntax
DellObjectRange
Access
Read-only
Memory Device State Capabilities
Name
memoryDeviceStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.3
Description
Defines the capabilities of the memory device.
Syntax
DellStateCapabilities
Access
Read-only
Memory Device State Settings
Name
memoryDeviceStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.4
Description
Defines the state of the memory device.
Syntax
DellStateSettings
Access
Read-write
Memory Device Status
Name
memoryDeviceStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.5
Description
Defines the status of the memory device.
Syntax
DellStatus
Access
Read-only
Device Group
235
Memory Device Memory Port Index Reference
Name
memoryDeviceMemoryPortIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.6
Description
Defines the index of the memory port of which this memory device
is part.
Syntax
DellObjectRange
Access
Read-only
Memory Device Type
Name
memoryDeviceType
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.7
Description
Defines the type of the memory device.
Syntax
DellMemoryDeviceType (See Table 13-16.)
Access
Read-only
Memory Device Location Name
Name
memoryDeviceLocationName
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.8
Description
Defines the location name of the memory device.
Syntax
DellString
Access
Read-write
Memory Device Error Count
NOTE: Memory Device Failure Modes has now replaced this attribute. Memory Device Error Count should no
longer be used. If you use the Memory Device Error Count attribute, the value returned is always zero, and using
the attribute will have no effect.
.
236
Name
memoryDeviceErrorCount
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.9
Description
Defines the total number of Error Checking and Correction (ECC)
errors detected by the memory device. Writing a 0 (zero) to this
variable will reset the devices error counts.
Syntax
DellSigned32BitRange
Access
Read-write
Device Group
Memory Device Bank Location Name
Name
memoryDeviceBankLocationName
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.10
Description
Defines the bank location name of the memory device.
Syntax
DellString
Access
Read-only
Memory Device Type Details
Name
memoryDeviceTypeDetails
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.11
Description
Defines the detailed type of the memory device.
Syntax
DellMemoryDeviceTypeDetails (See Table 13-17.)
Access
Read-only
Memory Device Form Factor
Name
memoryDeviceFormFactor
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.12
Description
Defines the form factor of the memory device.
Syntax
DellMemoryDeviceFormFactor (See Table 13-15.)
Access
Read-only
Memory Device Set
Name
memoryDeviceSet
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.13
Description
Defines if the memory device is a part of a set. A zero (0) indicates
that this device is not part of a set.
Syntax
DellUnsigned32BitRange
Access
Read-only
Device Group
237
Memory Device Size
Name
memoryDeviceSize
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.14
Description
Defines the size in KB of the memory device.
Syntax
DellUnsigned32BitRange
Access
Read-only
Memory Device Speed
Name
memoryDeviceSpeed
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.15
Description
Defines the speed in nanoseconds of the memory device. A zero (0)
indicates that the speed is unknown.
Syntax
DellUnsigned32BitRange
Access
Read-only
Memory Device Total Bus Width
Name
memoryDeviceTotalBusWidth
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.16
Description
Defines the total number of bits, including ECC, used by the
memory device.
Syntax
DellUnsigned32BitRange
Access
Read-only
Memory Device Total Data Bus Width
238
Name
memoryDeviceTotalDataBusWidth
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.17
Description
Defines the total number of data bits used by the memory device.
Syntax
DellUnsigned32BitRange
Access
Read-only
Device Group
Memory Device Correctable Memory Event Count
NOTE: Memory Device Failure Modes has now replaced this attribute. Memory Device Correctable Memory Event
Count should no longer be used. If you use the Memory Device Correctable Memory Event Count attribute, the
value returned is always zero, and using the attribute will have no effect.
Name
memoryDeviceSingleBitErrorCount
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.18
Description
Defines the total number of Correctable Memory Events detected
by the memory device.
Syntax
DellSigned32BitRange
Access
Read-only
Memory Device Uncorrectable Memory Event Count
NOTE: Memory Device Failure Modes has now replaced this attribute. Memory Device Uncorrectable Memory
Event Count should no longer be used. If you use the Memory Device Uncorrectable Memory Event Count attribute,
the value returned is always zero, and using the attribute will have no effect.
Name
memoryDeviceMultiBitErrorCount
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.19
Description
Defines the total number of Uncorrectable Memory Events detected
by the memory device.
Syntax
DellSigned32BitRange
Access
Read-only
Memory Device Failure Modes
Name
memoryDeviceFailureModes
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.20
Description
Defines the failure modes of the memory device when the
memoryDeviceStatus attribute is not OK. It is a bit field that can be
used to report more than one type of failure mode by using a
combination of the defined bit masks.
Syntax
DellMemoryDeviceFailureModes
Access
Read-only
Device Group
239
Memory Device Manufacturer Name
Name
memoryDeviceManufacturerName
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.21
Description
Defines the manufacturer of the memory device.
Syntax
DellString
Access
Read-only
Memory Device Part Number Name
Name
memoryDevicePartNumberName
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.22
Description
Defines the manufacturer's part number for the memory device.
Syntax
DellString
Access
Read-only
Memory Device Serial Number Name
Name
memoryDeviceSerialNumberName
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.23
Description
Defines the serial number of the memory device.
Syntax
DellString
Access
Read-only
Memory Device Asset Tag Name
240
Name
memoryDeviceAssetTagName
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.24
Description
Defines the asset tag of the memory device.
Syntax
DellString
Access
Read-only
Device Group
Memory Device Speed Name
Name
memoryDeviceSpeedName
Object ID
1.3.6.1.4.1.674.10892.1.1100.50.1.25
Description
This attribute defines the speed of the memory device in string format
with units specified in string.
Syntax
DellString
Access
Read-only
Memory Device Mapped Address Table
Name
memoryDeviceMappedAddressTable
Object ID
1.3.6.1.4.1.674.10892.1.1100.60
Description
Defines the Memory Device Mapped Address Table.
Syntax
SEQUENCE OF MemoryDeviceMappedAddressTableEntry
Access
Not accessible
Memory Device Mapped Address Table Entry
Name
memoryDeviceMappedAddressTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1100.60.1
Description
Defines the Memory Device Mapped Address Table entry.
Syntax
MemoryDeviceMappedAddressTableEntry
Access
Not accessible
Index
memoryDeviceMappedAddresschassisIndex,
memoryDeviceMappedAddressIndex
Memory Device Mapped Address Chassis Index
Name
memoryDeviceMappedAddresschassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.60.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Device Group
241
Memory Device Mapped Address Index
Name
memoryDeviceMappedAddressIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.60.1.2
Description
Defines the index (one-based) of the memory device mapped
address in this chassis.
Syntax
DellObjectRange
Access
Read-only
Memory Device Mapped Address State Capabilities
Name
memoryDeviceMappedAddressStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1100.60.1.3
Description
Defines the capabilities of the memory device mapped address.
Syntax
DellStateCapabilities
Access
Read-only
Memory Device Mapped Address State Settings
Name
memoryDeviceMappedAddressStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1100.60.1.4
Description
Defines the state of the memory device mapped address.
Syntax
DellStateSettings
Access
Read-write
Memory Device Mapped Address Status
242
Name
memoryDeviceMappedAddressStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.60.1.5
Description
Defines the status of the memory device mapped address.
Syntax
DellStatus
Access
Read-only
Device Group
Memory Device Index Reference
Name
memoryDeviceIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1100.60.1.6
Description
Defines the index of the memory device(s) associated with this
memory device mapped address.
Syntax
DellObjectRange
Access
Read-only
Memory Device Mapped Address Row Position
Name
memoryDeviceMappedAddressRowPosition
Object ID
1.3.6.1.4.1.674.10892.1.1100.60.1.7
Description
Defines the position of the referenced memory in a row of the
memory device mapped address.
Syntax
DellUnsigned32BitRange
Access
Read-only
Memory Device Mapped Address Interleave Position
Name
memoryDeviceMappedAddressInterleavePosition
Object ID
1.3.6.1.4.1.674.10892.1.1100.60.1.8
Description
Defines the position of the referenced memory in an interleave of
the memory device mapped address.
Syntax
DellUnsigned32BitRange
Access
Read-only
Memory Device Mapped Address Interleave Depth
Name
memoryDeviceMappedAddressInterleaveDepth
Object ID
1.3.6.1.4.1.674.10892.1.1100.60.1.9
Description
Defines the maximum number of consecutive rows from the
referenced memory device that are accessed in a single interleaved
transfer in the memory device mapped address.
Syntax
DellUnsigned32BitRange
Access
Read-only
Device Group
243
Memory Device Mapped Address Starting Address
Name
memoryDeviceMappedAddressStartingAddress
Object ID
1.3.6.1.4.1.674.10892.1.1100.60.1.10
Description
Defines the physical starting address in KB of the memory device
mapped address.
Syntax
DellUnsigned64BitRange
Access
Read-only
Memory Device Mapped Address Ending Address
Name
memoryDeviceMappedAddressEndingAddress
Object ID
1.3.6.1.4.1.674.10892.1.1100.60.1.11
Description
Defines the physical ending address in KB of the memory device
mapped address.
Syntax
DellUnsigned64BitRange
Access
Read-only
Generic Device Table
Name
genericDeviceTable
Object ID
1.3.6.1.4.1.674.10892.1.1100.70
Description
Defines the Generic Device Table.
Syntax
SEQUENCE OF GenericDeviceTableEntry
Access
Not accessible
Generic Device Table Entry
244
Name
genericDeviceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1100.70.1
Description
Defines the Generic Device Table entry.
Syntax
GenericDeviceTableEntry
Access
Not accessible
Index
genericDevicechassisIndex, genericDeviceIndex
Device Group
Generic Device Chassis Index
Name
genericDevicechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.70.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Generic Device Index
Name
genericDeviceIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.70.1.2
Description
Defines the index of the generic device in this chassis.
Syntax
DellObjectRange
Access
Read-only
Generic Device State Capabilities
Name
genericDeviceStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1100.70.1.3
Description
Defines the capabilities of the generic device.
Syntax
DellStateCapabilities
Access
Read-only
Generic Device State Settings
Name
genericDeviceStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1100.70.1.4
Description
Defines the state of the generic device.
Syntax
DellStateSettings
Access
Read-write
Device Group
245
Generic Device Status
Name
genericDeviceStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.70.1.5
Description
Defines the status of the generic device.
Syntax
DellStatus
Access
Read-only
Generic Device System Slot Index Reference
Name
genericDeviceSystemSlotIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1100.70.1.6
Description
Defines the index of the system slot into which this generic device
is plugged.
Syntax
DellObjectRange
Access
Read-only
Generic Device Type
Name
genericDeviceType
Object ID
1.3.6.1.4.1.674.10892.1.1100.70.1.7
Description
Defines the type of the generic device.
Syntax
DellGenericDeviceType (See Table 13-18.)
Access
Read-only
Generic Device Name
246
Name
genericDeviceName
Object ID
1.3.6.1.4.1.674.10892.1.1100.70.1.8
Description
Defines the name of the generic device.
Syntax
DellString
Access
Read-only
Device Group
PCI Device Table
Name
pCIDeviceTable
Object ID
1.3.6.1.4.1.674.10892.1.1100.80
Description
Defines the PCI Device Detail Table.
Syntax
SEQUENCE OF PCIDeviceTableEntry
Access
Not accessible
PCI Device Table Entry
Name
pCIDeviceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1100.80.1
Description
Defines the PCI Device Table entry.
Syntax
Not accessible
Access
PCIDeviceTableEntry
Index
pCIDevicechassisIndex, pCIDeviceIndex
PCI Device Chassis Index
Name
pCIDevicechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.80.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
Read-only
Access
DellObjectRange
PCI Device Index
Name
pCIDeviceIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.80.1.2
Description
Defines the index (one-based) of the PCI device in this chassis.
Syntax
DellObjectRange
Access
Read-only
Device Group
247
PCI Device State Capabilities
Name
pCIDeviceStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1100.80.1.3
Description
Defines the capabilities of the PCI device.
Syntax
DellStateCapabilities
Access
Read-only
PCI Device State Settings
Name
pCIDeviceStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1100.80.1.4
Description
Defines the state of the PCI device.
Syntax
DellStateSettings
Access
Read-write
PCI Device Status
Name
pCIDeviceStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.80.1.5
Description
Defines the status of the PCI device.
Syntax
DellStatus
Access
Read-only
PCI Device System Slot Index Reference
248
Name
pCIDeviceSystemSlotIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1100.80.1.6
Description
Defines the index number of the system slot that this PCI device
is in.
Syntax
DellObjectRange
Access
Read-only
Device Group
PCI Device Data Bus Width
Name
pCIDeviceDataBusWidth
Object ID
1.3.6.1.4.1.674.10892.1.1100.80.1.7
Description
Defines the bus width of the PCI device in this chassis.
Syntax
DellUnsigned32BitRange
Access
Read-only
PCI Device Manufacturer Name
Name
pCIDeviceManufacturerName
Object ID
1.3.6.1.4.1.674.10892.1.1100.80.1.8
Description
Defines the name of the PCI device manufacturer.
Syntax
DellString
Access
Read-only
PCI Device Description Name
Name
pCIDeviceDescriptionName
Object ID
1.3.6.1.4.1.674.10892.1.1100.80.1.9
Description
Defines the descriptive name of the PCI device.
Syntax
DellString
Access
Read-only
PCI Device Speed
Name
pCIDeviceSpeed
Object ID
1.3.6.1.4.1.674.10892.1.1100.80.1.10
Description
Defines the bus speed in MHz of the PCI device in this chassis.
A zero (0) indicates that the speed is unknown.
Syntax
DellUnsigned32BitRange
Access
Read-only
Device Group
249
PCI Device Adapter Fault
Name
pCIDeviceAdapterFault
Object ID
1.3.6.1.4.1.674.10892.1.1100.80.1.11
Description
Defines whether the PCI device in this chassis has detected a fault.
Syntax
DellBoolean
Access
Read-only
PCI Device Configuration Space Table
Name
pCIDeviceConfigurationSpaceTable
Object ID
1.3.6.1.4.1.674.10892.1.1100.82
Description
Defines the PCI Device Configuration Table.
Syntax
SEQUENCE OF PCIDeviceConfigurationSpaceTableEntry
Access
Not accessible
PCI Device Configuration Space Table Entry
Name
pCIDeviceConfigurationSpaceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1100.82.1
Description
Defines the PCI Device Configuration Table entry.
Syntax
PCIDeviceConfigurationSpaceTableEntry
Access
Not accessible
Index
pCIDeviceConfigurationSpacechassisIndex,
pCIDeviceConfigurationSpaceIndex
PCI Device Configuration Space Chassis Index
250
Name
pCIDeviceConfigurationSpacechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.82.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Device Group
PCI Device Configuration Space Index
Name
pCIDeviceConfigurationSpaceIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.82.1.2
Description
Defines the index (one-based) of the PCI device configuration in
this chassis.
Syntax
DellObjectRange
Access
Read-only
PCI Device Configuration Space State Capabilities
Name
pCIDeviceConfigurationSpaceStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1100.82.1.3
Description
Defines the capabilities of the PCI device configuration.
Syntax
DellStateCapabilities
Access
Read-only
PCI Device Configuration Space State Settings
Name
pCIDeviceConfigurationSpaceStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1100.82.1.4
Description
Defines the state of the PCI device configuration.
Syntax
DellStateSettings
Access
Read-write
PCI Device Configuration Space Status
Name
pCIDeviceConfigurationSpaceStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.82.1.5
Description
Defines the status of the PCI device configuration.
Syntax
DellStatus
Access
Read-only
Device Group
251
PCI Device Index Reference
Name
pCIDeviceIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1100.82.1.6
Description
Defines the index number of PCI device that this configuration
applies to.
Syntax
DellObjectRange
Access
Read-only
PCI Device Configuration Space Bus Number
Name
pCIDeviceConfigurationSpaceBusNumber
Object ID
1.3.6.1.4.1.674.10892.1.1100.82.1.7
Description
Defines the bus number of the PCI device configuration in this chassis.
Syntax
DellUnsigned32BitRange
Access
Read-only
PCI Device Configuration Space Device Number
Name
pCIDeviceConfigurationSpaceDeviceNumber
Object ID
1.3.6.1.4.1.674.10892.1.1100.82.1.8
Description
Defines the device number of the PCI device in this chassis.
Syntax
DellUnsigned32BitRange
Access
Read-only
PCI Device Configuration Space Function Number
252
Name
pCIDeviceConfigurationSpaceFunctionNumber
Object ID
1.3.6.1.4.1.674.10892.1.1100.82.1.9
Description
Defines the function number of the PCI device in this chassis.
Syntax
DellUnsigned32BitRange
Access
Read-only
Device Group
PCI Device Configuration Space Header
Name
pCIDeviceConfigurationSpaceHeader
Object ID
1.3.6.1.4.1.674.10892.1.1100.82.1.10
Description
Defines the common configuration space header of the PCI device.
Syntax
OCTET STRING (SIZE(0..1025))
Access
Read-only
Network Device Table
Name
networkDeviceTable
Object ID
1.3.6.1.4.1.674.10892.1.1100.90
Description
Defines the Network Device Table.
Syntax
SEQUENCE OF NetworkDeviceTableEntry
Access
Not accessible
Network Device Table Entry
Name
networkDeviceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1
Description
Defines the Network Device Table Entry.
Syntax
NetworkDeviceTableEntry
Access
Not accessible
Network Device Chassis Index
Name
networkDeviceChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.1
Description
Defines the index (one-based) of the chassis that contains the
network device.
Syntax
DellObjectRange
Access
Read-only
Device Group
253
Network Device Index
Name
networkDeviceIndex
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.2
Description
Defines the index (one-based) of the network device.
Syntax
DellObjectRange
Access
Read-only
Network Device Status
Name
networkDeviceStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.3
Description
Defines the status of the network device.
Syntax
DellStatus
Access
Read-only
Network Device Connection Status
Name
networkDeviceConnectionStatus
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.4
Description
Defines the connection status of the network device.
Syntax
DellNetworkDeviceConnectionStatus (see Table 13-20)
Access
Read-only
Network Device Description Name
254
Name
networkDeviceDescriptionName
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.5
Description
Defines the description of the network device.
Syntax
DellString
Access
Read-only
Device Group
Network Device Product Name
Name
networkDeviceProductName
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.6
Description
Defines the product name of the network device.
Syntax
DellString
Access
Read-only
Network Device Vendor Name
Name
networkDeviceVendorName
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.7
Description
Defines the name of the vendor of the network device.
Syntax
DellString
Access
Read-only
Network Device Service Name
Name
networkDeviceServiceName
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.8
Description
Defines the service name of the network device.
Syntax
DellString
Access
Read-only
Network Device Driver Image Path Name
Name
networkDeviceDriverImagePathName
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.9
Description
Defines the path to the binary image of the driver for the
network device.
Syntax
DellString
Access
Read-only
Device Group
255
Network Device Driver Version Name
Name
networkDeviceDriverVersionName
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.10
Description
Defines the version of the driver for the network device.
Syntax
DellString
Access
Read-only
Network Device IP Address
Name
networkDeviceIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.11
Description
Defines the IP address of the network device.
Syntax
IpAddress
Access
Read-only
Network Device IP Subnet Mask
Name
networkDeviceIPSubnetMask
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.12
Description
Defines the IP subnet mask for the IP address currently assigned to
the network device.
Syntax
IpAddress
Access
Read-only
Network Device Default Gateway IP Address
256
Name
networkDeviceDefaultGatewayIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.13
Description
Defines the IP address of the default gateway for the network device.
Syntax
IpAddress
Access
Read-only
Device Group
Network Device DHCP Server IP Address
Name
networkDeviceDHCPServerIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.14
Description
Defines the IP address of the DHCP server that was used to obtain
the IP address of the network device if DHCP was used to configure
the network device.
Syntax
IpAddress
Access
Read-only
Network Device Current MAC Address
Name
networkDeviceCurrentMACAddress
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.15
Description
Defines the current MAC address of the network device.
Syntax
DellMACAddress
Access
Read-only
Network Device Permanent MAC Address
Name
networkDevicePermanentMACAddress
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.16
Description
Defines the permanent MAC address of the network device.
Syntax
DellMACAddress
Access
Read-only
Network Device PCI Bus Number
Name
networkDevicePCIBusNumber
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.17
Description
Defines the PCI bus number of the network device.
Syntax
DellUnsigned8BitRange
Access
Read-only
Device Group
257
Network Device PCI Device Number
Name
networkDevicePCIDeviceNumber
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.18
Description
Defines the PCI device number of the network device.
Syntax
DellUnsigned8BitRange
Access
Read-only
Network Device PCI Function Number
Name
networkDevicePCIFunctionNumber
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.19
Description
Defines the PCI function number of the network device.
Syntax
DellUnsigned8BitRange
Access
Read-only
Network Device IRQ
Name
networkDeviceIRQ
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.20
Description
Defines the interrupt request number of the network device.
Syntax
DellUnsigned16BitRange
Access
Read-only
Network Device Base IO Port Address
258
Name
networkDeviceBaseIOPortAddress
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.21
Description
Defines the base input/outport port address of the network device.
Syntax
DellUnsigned32BitRange
Access
Read-only
Device Group
Network Device Teaming Flags
Name
networkDeviceTeamingFlags
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.22
Description
Defines the teaming features of the network device.
Syntax
DellNetworkDeviceTeamingFlags (see Table 13-21)
Access
Read-only
Network Device TOE Capability Flags
Name
networkDeviceTOECapabilityFlags
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.23
Description
Defines the TCP/IP Offload Engine (TOE) capability flags of the
network device.
Syntax
DellNetworkDeviceTOECapabilityFlags (see Table 13-22)
Access
Read-only
Network Device TOE Enabled
Name
networkDeviceTOEEnabled
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.24
Description
Defines if TOE is enabled for the network device.
Syntax
DellBoolean
Access
Read-only
Network Device RDMA Capability Flags
Name
networkDeviceRDMACapabilityFlags
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.25
Description
Defines the Remote Direct Memory Access (RDMA) capability flags
of the network device.
Syntax
DellNetworkDeviceRDMACapabilityFlags (see Table 13-23)
Access
Read-only
Device Group
259
Network Device RDMA Enabled
Name
networkDeviceRDMAEnabled
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.26
Description
Defines if RDMA is enabled for the network device.
Syntax
DellBoolean
Access
Read-only
Network Device iSCSI Capability Flags
Name
networkDeviceiSCSICapabilityFlags
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.27
Description
Defines the Internet Small Computer System Interface (iSCSI)
capability flags of the network device.
Syntax
DellNetworkDeviceiSCSICapabilityFlags (see Table 13-24)
Access
Read-only
Network Device iSCSI Enabled
260
Name
networkDeviceiSCSIEnabled
Object ID
1.3.6.1.4.1.674.10892.1.1100.90.1.28
Description
Defines if iSCSI is enabled for the network device.
Syntax
DellBoolean
Access
Read-only
Device Group
Device Group Variable Values
This section includes definitions for server administrator-specific variable values used in this section.
Table 13-1.
Pointing Device Type
Variable Name: DellPointingDeviceType
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceTypeIsOther(1)
Device type is not one of the following:
deviceTypeIsUnknown(2)
Device type is unknown.
deviceTypeIsAMouse(3)
Device type is a mouse.
deviceTypeIsATrackBall(4)
Device type is a track ball.
deviceTypeIsATrackPoint(5)
Device type is a track point.
deviceTypeIsAGlidePoint(6)
Device type is a glide point.
deviceTypeIsATouchPad(7)
Device type is a touch pad.
Table 13-2.
Processor Device Status State
Variable Name: DellProcessorDeviceStatusState
Data Type: Integer
Possible Data Values
Meaning of Data Value
other(1)
Processor device type is not one of the following:
unknown(2)
Device type is unknown.
enabled(3)
Device is enabled.
userDisabled(4)
Device is disabled by the user.
biosDisabled(5)
Device has its BIOS disabled.
idle(6)
Device is idle.
Device Group
261
Table 13-3.
Processor Device Status Reading
Variable Name: DellProcessorDeviceStatusReading
Data Type: Integer
NOTE: These values are bit masks, so combination values are possible.
Possible Data Values
Meaning of Data Value
internalError(1)
The processor experienced an internal error
thermalTrip(2)
The processor experienced a thermal trip
configurationError(32)
The processor experienced a configuration error
processorPresent(128)
The processor is present
processorDisabled(256)
The processor is disabled
terminatorPresent(512)
The terminator is Present
processorThrottled(1024)
The processor is throttled
Table 13-4.
Processor Device Type
Variable Name: DellProcessorDeviceType
Data Type: Integer
262
Possible Data Values
Meaning of Data Value
deviceTypeIsOther(1)
The processor device type is not one of the
following values:
deviceTypeIsUnknown(2)
The processor device type is unknown.
deviceTypeIsCPU(3)
The processor device type is a central
processing unit.
deviceTypeIsMathProcessor(4)
The processor device type is a math processor.
deviceTypeIsDSP(5)
The processor device type is a digital
signal processor.
deviceTypeIsAVideoProcessor(6)
The processor device is a video processor.
Device Group
Table 13-5.
Processor Upgrade Information
Variable Name: DellProcessorUpgradeInformation
Data Type: Integer
Possible Data Values
Meaning of Data Value
processorUpgradeIsOther(1)
The upgrade device type is not one of the following:
processorUpgradeIsUnknown(2)
Upgrade device type is unknown.
processorUpgradeIsByDaughterBoard(3)
Upgrade device is on a daughter board.
processorUpgradeIsByZIFSocket(4)
Upgrade device is in a zero insertion force (ZIF) socket.
processorUpgradeIsByReplacement(5)
Upgrade device is a replacement.
processorUpgradeIsNone(6)
There is no upgrade device.
processorUpgradeIsByLIFSocket(7)
Upgrade device is in a low insertion force (LIF) socket.
processorUpgradeIsBySlot1(8)
Upgrade device is a SLOT 1 processor.
processorUpgradeIsBySlot2(9)
Upgrade device is a SLOT 2 processor.
processorUpgradeIsBy370PinSocket(10)
Upgrade device is a 370 pin socket.
processorUpgradeIsBySlotA(11)
Upgrade is by Slot A.
processorUpgradeIsBySlotM(12)
Upgrade is by Slot M.
processorUpgradeIsByScoket423(13)
Upgrade is by Socket 423.
processorUpgradeIsBySocketA(14)
Upgrade is by Socket A (Socket 462).
processorUpgradeIsBySocket478(15)
Upgrade is by Socket 478.
processorUpgradeIsBySocket754(16)
Upgrade is by Socket 754.
processorUpgradeIsBySocket940(17)
Upgrade is by Socket 940.
processorUpgradeIsBySocket939(18)
Upgrade is by Socket 939.
processorUpgradeIsBySocketmPGA604(19) Upgrade is by Socket mPGA604.
processorUpgradeIsBySocketLGA771(20)
Upgrade is by Socket LGA771.
processorUpgradeIsBySocketLGA775(21)
Upgrade is by Socket LGA775.
Device Group
263
Table 13-6.
Processor Device Family
Variable Name: DellProcessorDeviceFamily
Data Type: Integer
264
Possible Data Values
Meaning of Data Value
deviceFamilyIsOther(1)
The processor family is not one of the
following values:
deviceFamilyIsUnknown(2)
The processor family is unknown.
deviceFamilyIs8086(3)
The processor family is 8086.
deviceFamilyIs80286(4)
The processor family is 80286.
deviceFamilyIs80386(5)
The processor family is 80386.
deviceFamilyIs80486(6)
The processor family is 80486.
deviceFamilyIS8087(7)
The processor family is 8087.
deviceFamilyIs80287(8)
The processor family is 80287.
deviceFamilyIs80387(9)
The processor family is 80387.
deviceFamilyIs80487(10)
The processor family is 80487.
deviceFamilyIsPentium(11)
The processor family is Intel® Pentium®.
deviceFamilyIsPentiumPro(12)
The processor family is Pentium Pro.
deviceFamilyIsPentium2(13)
The processor family is Pentium II.
deviceFamilyIsPentiumMMX(14)
The processor family is Pentium MMX™.
deviceFamilyIsCeleron(15)
The processor family is Celeron®.
deviceFamilyIsXeon(16)
The processor family is Xeon™.
deviceFamilyIsPentium3(17)
The processor family is Pentium III.
deviceFamilyIsPentium3Xeon(18)
The processor family is Pentium III Xeon.
deviceFamilyIsPentium3Step(19)
The processor family is Pentium III Speed Step.
deviceFamilyIsPentiumItanium(20)
The processor family is Itanium®.
deviceFamilyIsIntelXeon(21)
The processor family is Intel Xeon.
deviceFamilyIsPentium4(22)
The processor family is Pentium 4.
deviceFamilyIsIntelXeonMP(23)
The processor family is Intel Xeon MP.
deviceFamilyIsIntelItanium2(24)
The processor family is Intel Itanium 2.
deviceFamilyIsK5(25)
The processor family is K5.
deviceFamilyIsK6(26)
The processor family is K6.
deviceFamilyIsK6-2(27)
The processor family is K6-2.
Device Group
Table 13-6.
Processor Device Family (continued)
Variable Name: DellProcessorDeviceFamily
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceFamilyIsK6-3(28)
The processor family is K6-3.
deviceFamilyIsAMDAthlon(29)
The processor family is AMD™ Athlon™.
deviceFamilyIsAMD2900(30)
The processor family is AMD2900.
deviceFamilyIsK6-2Plus(31)
The processor family is K6-2+.
deviceFamilyIsPowerPC(32)
The processor family is Power PC.
deviceFamilyIsPowerPC601(33)
The processor family is Power PC 601.
deviceFamilyIsPowerPC603(34)
The processor family is Power PC 603
deviceFamilyIsPowerPC603Plus(35)
The processor family is Power PC 603+.
deviceFamilyIsPowerPC604(36)
The processor family is Power PC 604.
deviceFamilyIsPowerPC620(37)
The processor family is Power PC 620.
deviceFamilyIsPowerPCx704(38)
The processor family is Power PC x704.
deviceFamilyIsPowerPC750(39)
The processor family is Power PC 750.
deviceFamilyIsAlpha(48)
The processor family is Alpha.
deviceFamilyIsAlpha21064(49)
The processor family is Alpha 21064.
deviceFamilyIsAlpha21066(50)
The processor family is Alpha 21066.
deviceFamilyIsAlpha21164(51)
The processor family is Alpha 21164.
deviceFamilyIsAlpha21164PC(52)
The processor family is Alpha 21164PC.
deviceFamilyIsAlpha21164a(53)
The processor family is Alpha 21164a.
deviceFamilyIsAlpha21264(54)
The processor family is Alpha 21264.
deviceFamilyIsAlpha21364(55)
The processor family is Alpha 21364.
deviceFamilyIsMIPS(64)
The processor family is MIPS.
deviceFamilyIsMIPSR4000(65)
The processor family is MIPS R4000.
deviceFamilyIsMIPSR4200(66)
The processor family is MIPS R4200.
deviceFamilyIsMIPSR4400(67)
The processor family is MIPS R4400.
deviceFamilyIsMIPSR4600(68)
The processor family is MIPS R4600.
deviceFamilyIsMIPSR10000(69)
The processor family is MIPS R10000.
deviceFamilyIsSPARC(80)
The processor family is SPARC.
deviceFamilyIsSuperSPARC(81)
The processor family is SuperSPARC.
Device Group
265
Table 13-6.
Processor Device Family (continued)
Variable Name: DellProcessorDeviceFamily
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceFamilyIsmicroSPARCII(82)
The processor family is microSPARC II.
deviceFamilyIsmicroSPARCIIep(83)
The processor family is microSPARC IIep.
deviceFamilyIsUltraSPARC(84)
The processor family is UltraSPARC.
deviceFamilyIsUltraSPARCII(85)
The processor family is UltraSPARC II.
deviceFamilyIsUltraSPARCIIi(86)
The processor family is UltraSPARC IIi.
deviceFamilyIsUltraSPARCIII(87)
The processor family is UltraSPARC III.
deviceFamilyIsUltraSPARCIIIi(88)
The processor family is UltraSPARC IIIi.
deviceFamilyIs68040(96)
The processor family is 68040 Family.
deviceFamilyIs68xxx(97)
The processor family is 68xxx.
deviceFamilyIs68000(98)
The processor family is 68000.
deviceFamilyIs68010(99)
The processor family is 68010.
deviceFamilyIs68020(100)
The processor family is 68020.
deviceFamilyIs68030(101)
The processor family is 68030.
deviceFamilyIsHobbit(112)
The processor family is Hobbit.
deviceFamilyIsCrusoeTM5000(120)
The processor family is Crusoe TM5000.
deviceFamilyIsCrusoeTM3000(121)
The processor family is Crusoe TM3000.
deviceFamilyIsEfficeonTM8000(122)
The processor family is Efficeon TM8000.
deviceFamilyIsWeitek(128)
The processor family is Weitek.
deviceFamilyIsAMDAthlon64(131)
The processor family is AMD Athlon 64.
deviceFamilyIsAMDOpteron(132)
The processor family is AMD Opteron™.
deviceFamilyIsAMDSempron(133)
The processor family is AMD Sempron™.
deviceFamilyIsAMDTurion64Mobile(134)
The processor family is AMD Turion™ 64 Mobile
Technology.
deviceFamilyIsAMDOpteronDualCore(135)
The processor family is Dual-Core AMD
Opteron.
deviceFamilyIsAMDAthlon64X2DualCore(136) The processor family is AMD Athlon 64 X2
Dual-Core.
266
deviceFamilyIsPA-RISC(144)
The processor family is PA-RISC.
deviceFamilyIsPA-RISC8500(145)
The processor family is PA-RISC 8500.
Device Group
Table 13-6.
Processor Device Family (continued)
Variable Name: DellProcessorDeviceFamily
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceFamilyIsPA-RISC8000(146)
The processor family is PA-RISC 8000.
deviceFamilyIsPA-RISC7300LC(147)
The processor family is PA-RISC 7300LC.
deviceFamilyIsPA-RISC7200(148)
The processor family is PA-RISC 7200.
deviceFamilyIsPA-RISC7100LC(149)
The processor family is PA-RISC 7100LC.
deviceFamilyIsPA-RISC7100(150)
The processor family is PA-RISC 7100.
deviceFamilyIsV30(160)
The processor family is V30.
deviceFamilyIsM1(176)
The processor family is M1.
deviceFamilyIsM2(177)
The processor family is M2.
deviceFamilyIsAS400(180)
The processor family is AS400.
deviceFamilyIsAMDAthlonXP(182)
The processor family is AMD Athlon XP.
deviceFamilyIsAMDAthlonMP(183)
The processor family is AMD Athlon MP.
deviceFamilyIsAMDDuron(184)
The processor family is AMD Duron™.
deviceFamilyIsIntelPentiumM(185)
The processor family is Intel Pentium M.
deviceFamilyIsIntelCeleronD(186)
The processor family is Intel Celeron D.
deviceFamilyIsIntelPentiumD(187)
The processor family is Intel Pentium D.
deviceFamilyIsIntelPentiumExtreme(188)
The processor family is Intel Pentium Processor
Extreme Edition.
deviceFamilyIsIntelCore2(190)
The processor family is Intel Core™ 2 processor.
deviceFamilyIsIBM390(200)
The processor family is IBM390.
deviceFamilyIsG4(201)
The processor family is G4.
deviceFamilyIsG5(202)
The processor family is G5.
deviceFamilyIsi860(250)
The processor family is i860.
deviceFamilyIsi960(251)
The processor family is i960.
Device Group
267
Table 13-7.
Cache Device Type
Variable Name: DellCacheDeviceType
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceTypeIsOther(1)
System cache type is not one of the following:
deviceTypeIsUnknown(2)
System cache type is unknown.
deviceTypeIsInstruction(3)
System cache type is instruction.
deviceTypeIsData(4)
System cache type is data.
deviceTypeIsUnified(5)
System cache type is both instruction and data.
Table 13-8.
Cache Device Level
Variable Name: DellCacheDeviceLevel
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceLevelIsOther(1)
Device level is not one of the following:
deviceLevelIsUnknown(2)
Device level is unknown.
deviceLevelIsPrimary(3)
Device level is primary.
deviceLevelIsSecondary(4)
Device level is secondary.
deviceLevelIsTertiary(5)
Device level is tertiary.
Table 13-9.
Cache Device Write Policy
Variable Name: DellCacheDeviceWritePolicy
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceWritePolicyIsOther(1)
Device write policy is not one of the following:
deviceWritePolicyIsUnknown(2)
Device write policy is unknown.
deviceWritePolicyIsWriteBack(3)
Device write policy is write back.
deviceWritePolicyIsWriteThrough(4) Device write policy is write through.
deviceWritePolicyIsVariesByAddress(5) Device write policy varies by address.
deviceWritePolicyIsDeterminedByIO(6) Device write policy is determined by I/O query.
268
Device Group
Table 13-10. Cache Device Status State
Variable Name: DellCacheDeviceStatusState
Data Type: Integer
Possible Data Values
Meaning of Data Value
other(1)
Device state is not one of the following:
unknown(2)
Device state is unknown.
enabled(3)
Device is enabled.
userDisabled(4)
Device is disabled by the user.
biosDisabled(5)
Device basic input/output system (BIOS) is disabled.
Table 13-11. Cache Device ECC Type
Variable Name: DellPointingDeviceType
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceTypeIsOther(1)
Device type is not one of the following:
deviceTypeIsUnknown(2)
Device type is unknown.
deviceTypeIsAMouse(3)
Device type is a mouse.
deviceTypeIsATrackBall(4)
Device type is a track ball.
deviceTypeIsATrackPoint(5)
Device type is a track point.
deviceTypeIsAGlidePoint(6)
Device type is a glide point.
deviceTypeIsATouchPad(7)
Device type is a touch pad.
Device Group
269
Table 13-12. Cache Device Associativity
Variable Name: DellCacheDeviceAssociativity
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceAssociativityIsOther(1)
Device associativity is not one of the
following:
deviceAssociativityIsUnknown(2)
Device associativity is unknown.
deviceAssociativityIsDirectMapped(3)
Device is direct mapped.
deviceAssociativityIsTwoWaySetAssociative(4)
Device is two-way set associative.
deviceAssociativityIsFourWaySetAssociative(5)
Device is four-way set associative.
deviceAssociativityIsFullyAssociative(6)
Device is fully associative.
deviceAssociativityIsEightWaySetAssociative(7)
Device is eight-way set associative.
deviceAssociativityIsSixteenWaySetAssociative(8)
Device is sixteen-way set associative.
Table 13-13. Cache Device Location
Variable Name: DellCacheDeviceLocation
Data Type: Integer
270
Possible Data Values
Meaning of Data Value
deviceLocationIsOther(1)
Device location is not one of the following:
deviceLocationIsUnknown(2)
Device location is unknown.
deviceLocationIsInternal(3)
Device location is internal.
deviceLocationIsExternal(4)
Device location is external.
Device Group
Table 13-14. Cache Device Static Random-Access Memory (SRAM) Type
Variable Name: DellCacheDeviceSRAMType
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceSRAMTypeIsOther(1)
Device SRAM type is not one of the following:
deviceSRAMTypeIsUnknown(2)
Device SRAM type is unknown.
deviceSRAMTypeIsNonBurst(3)
Device SRAM type is nonburst.
deviceSRAMTypeIsBurst(4)
Device SRAM type is burst.
deviceSRAMTypeIsPipeBurst(5)
Device SRAM type is pipeburst.
deviceSRAMTypeIsSynchronous(6)
Device SRAM type is synchronous.
deviceSRAMTypeIsAsynchronous(7)
Device SRAM type is asynchronous.
Table 13-15. Memory Device Type Form Factor
Variable Name: DellMemoryDeviceFormFactor
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceFormFactorIsOther(1)
Device form factor is not one of the following:
deviceFormFactorIsUnknown(2)
Device form factor is unknown.
deviceFormFactorIsSIMM(3)
Device form factor is SIMM.
deviceFormFactorIsSIP(4)
Device form factor is SIP.
deviceFormFactorIsAChip(5)
Device form factor is a chip.
deviceFormFactorIsDIP(6)
Device form factor is DIP.
deviceFormFactorIsZIP(7)
Device form factor is ZIP.
deviceFormFactorIsAProprietaryCard(8) Device form factor is a proprietary card.
deviceFormFactorIsDIMM(9)
Device form factor is DIMM.
deviceFormFactorIsTSOP(10)
Device form factor is TSOP.
deviceFormFactorIsARowOfChips(11)
Device form factor is a row of chips.
deviceFormFactorIsRIMM(12)
Device form factor is RIMM.
deviceFormFactorIsSODIMM(13)
Device form factor is SODIMM.
deviceFormFactorIsSRIMM(14)
Device form factor is SRIMM.
deviceFormFactorIsFBDIMM(15)
Device form factor is FB-DIMM.
Device Group
271
Table 13-16. Memory Device Type
Variable Name: DellMemoryDeviceType
Data Type: Integer
272
Possible Data Values
Meaning of Data Value
deviceTypeIsOther(1)
Device type is not one of the following:
deviceTypeIsUnknown(2)
Device type is unknown.
deviceTypeIsDRAM(3)
Device type is DRAM.
deviceTypeIsEDRAM(4)
Device type is EDRAM.
deviceTypeIsVRAM(5)
Device type is VRAM.
deviceTypeIsSRAM(6)
Device type is SRAM.
deviceTypeIsRAM(7)
Device type is RAM.
deviceTypeIsROM(8)
Device type is ROM.
deviceTypeIsFLASH(9)
Device type is FLASH.
deviceTypeIsEEPROM(10)
Device type is EEPROM.
deviceTypeIsFEPROM(11)
Device type is FEPROM.
deviceTypeIsEPROM(12)
Device type is EPROM.
deviceTypeIsCDRAM(13)
Device type is CDRAM.
deviceTypeIs3DRAM(14)
Device type is 3DRAM.
deviceTypeIsSDRAM(15)
Device type is SDRAM.
deviceTypeIsSGRAM(16)
Device type is SGRAM.
deviceTypeIsRDRAM(17)
Device type is RDRAM.
deviceTypeIsDDR(18)
Device type is DDR.
deviceTypeIsDDR2(19)
Device type is DDR2.
deviceTypeIsDDR2FBDIMM(20)
Device type is DDR2 FB-DIMM.
Device Group
Table 13-17. Memory Device Type Details
Variable Name: DellMemoryDeviceTypeDetails
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceTypeDeatilIsOther(1)
The detailed device type is not one of the
following:
deviceTypeDetailIsUnknown(2)
The detailed device type is unknown.
deviceTypeDetailIsFastPaged(3)
The detailed device type is fast paged.
deviceTypeDetailIsStaticColumn(4)
The detailed device type is static column.
deviceTypeDetailIsPseudoStatic(5)
The detailed device type is pseudo-static.
deviceTypeDetailIsRAMBUS(6)
The detailed device type is RAMBUS.
deviceTypeDetailIsSynchronous(7)
The detailed device type is synchronous.
deviceTypeDetailIsCMOS(8)
The detailed device type is CMOS.
deviceTypeDetailIsEDO(9)
The detailed device type is EDO.
deviceTypeDetailIsWindowDRAM(10)
The detailed device type is "Window" DRAM.
deviceTypeDetailIsCacheDRAM(11)
The detailed device type is Cache DRAM.
deviceTypeDetailIsNonVolatile(12)
The detailed device type is nonvolatile.
Table 13-18. Generic Device Type
Variable Name: DellGenericDeviceType
Data Type: Integer
Possible Data Values
Meaning of Data Value
deviceTypeIsOther(1)
Device type is not one of the following:
deviceTypeIsUnknown(2)
Device type is unknown.
deviceTypeIsAVideoDevice(3)
Device type is a video.
deviceTypeIsASCSIController(4)
Device type is a SCSI controller.
deviceTypeIsAnEthernetDevice(5)
Device type is Ethernet.
deviceTypeIsTokenRingDevice(6)
Device type is token ring.
deviceTypeIsASoundDevice(7)
Device type is sound.
Device Group
273
Table 13-19. Memory Device Failure Modes
Variable Name: DellMemoryDeviceFailureModes
Data Type: Integer
NOTE: These values are bit masks, so combination values are possible.
Possible Data Values
Meaning of Data Value
(0)
Memory device has no faults.
eccSingleBitCorrectionWarningRate(1) Memory device has exceeded the Correctable
Memory Event warning rate.
eccSingleBitCorrectionFailureRate(2) Memory device has exceeded the Correctable
Memory Event failure rate.
eccMultiBitFault(4)
Memory device has encountered an
Uncorrectable Memory Event.
eccSingleBitCorrectionLoggingDis
abled(8)
Correctable Memory Event logging for
memory device has been disabled.
deviceDisabledBySpareActivation(16) Memory device is disabled because of spare
memory activation.
Table 13-20. Network Device Connection Status
Variable Name: DellNetworkDeviceConnectionStatus
Data Type: Integer
274
Possible Data Values
Meaning of Data Value
unknown(0)
Unable to determine connection status.
connected(1)
Media reports that device is connected.
disconnected(2)
Media reports that device is disconnected.
driverBad(3)
Driver cannot be opened to determine status.
driverDisabled(4)
Driver is disabled.
hardwareInitalizing(10)
Hardware is initializing.
hardwareResetting(11)
Hardware is resetting.
hardwareClosing(12)
Hardware is closing down.
hardwareNotReady(13)
Hardware is not ready.
Device Group
Table 13-21. Network Device Teaming Flags
Variable Name: DellNetworkDeviceTeamingFlags
Data Type: Integer
NOTE: These values are bit fields, so combination values are possible.
Possible Data Values
Meaning of Data Value
undefined(0)
Teaming flags are undefined.
noTeam(1)
Device is not part of any team.
teamingEnabled(2)
Teaming is enabled.
adapterFaultToleranceMode(4)
Adapter fault tolerance teaming mode.
loadBalancingMode(8)
Load balancing teaming mode.
Table 13-22. Network Device TOE Capability Flags
Variable Name: DellNetworkDeviceTOECapabilityFlags
Data Type: Integer
NOTE: These values are bit fields, so combination values are possible.
Possible Data Values
Meaning of Data Value
none(0)
Querying for TOE capability is not supported.
unknown(1)
Querying for TOE capability is supported but
query returned an error.
available(2)
Device has TOE capability.
notAvailable(4)
Device does not have TOE capability.
cannotBeDetermined(8)
Querying for TOE capability is supported but an
error prevented querying.
driverNotResponding(16)
Querying for TOE capability is supported but
driver did not respond to query.
Device Group
275
Table 13-23. Network Device RDMA Capability Flags
Variable Name: DellNetworkDeviceRDMACapabilityFlags
Data Type: Integer
NOTE: These values are bit fields, so combination values are possible.
Possible Data Values
Meaning of Data Value
none(0)
Querying for RDMA capability is not supported.
unknown(1)
Querying for RDMA capability is supported but
query returned an error.
available(2)
Device has RDMA capability.
notAvailable(4)
Device does not have RDMA capability.
cannotBeDetermined(8)
Querying for RDMA capability is supported but
an error prevented querying.
driverNotResponding(16)
Querying for RDMA capability is supported but
driver did not respond to query.
Table 13-24. Network Device iSCSI Capability Flags
Variable Name: DellNetworkDeviceiSCSICapabilityFlags
Data Type: Integer
NOTE: These values are bit fields, so combination values are possible.
276
Possible Data Values
Meaning of Data Value
none(0)
Querying for iSCSI capability is not supported.
unknown(1)
Querying for iSCSI capability is supported but
query returned an error.
available(2)
Device has iSCSI capability.
notAvailable(4)
Device does not have iSCSI capability.
cannotBeDetermined(8)
Querying for iSCSI capability is supported but an
error prevented querying.
driverNotResponding(16)
Querying for iSCSI capability is supported but
driver did not respond to query.
Device Group
Slot Group
The Slot Group provides information about the types of slots that your system supports.
This management information base (MIB) group also provides information about the voltages,
capabilities, states, and settings that are possible for these slots.
System Slot Group Table
The System Slot Group defines objects in the System Slot MIB table.
System Slot Table
The following object sets up the System Slot Table:
Name
systemSlotTable
Object ID
1.3.6.1.4.1.674.10892.1.1200.10
Description
Defines the System Slot Table.
Syntax
IntegerSystemStateTableEntry
Access
Not accessible
System Slot Table Entry
Name
systemSlotTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1
Description
Defines the System Slot Table entry.
Syntax
IntegerSystemSlotTableEntry
Access
Not accessible
Index
systemSlotchassisIndex, systemSlotIndex
Slot Group
277
System Slot Chassis Index
Name
systemSlotchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
System Slot Index
Name
systemSlotIndex
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.2
Description
Defines the index (one-based) of the system slot in this chassis.
Syntax
DellObjectRange
Access
Read-only
System Slot State Capabilities Unique
Name
systemSlotStateCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.3
Description
Defines the capabilities of the system slot.
Syntax
DellSystemSlotStateCapabilities (See Table 14-1.)
Access
Read-only
System Slot State Settings Unique
278
Name
systemSlotStateSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.4
Description
Defines the state of the system slot.
Syntax
DellSystemSlotStateSettings (See Table 14-2.)
Access
Read-only
Slot Group
System Slot Status
Name
systemSlotStatus
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.5
Description
Defines the status of the system slot.
Syntax
DellStatus
Access
Read-only
System Slot Current Usage
Name
systemSlotCurrentUsage
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.6
Description
Defines the current usage of the system slot.
Syntax
DellStatus
Access
Read-only
System Slot Type
Name
systemSlotType
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.7
Description
Defines the type of the system slot.
Syntax
DellSystemSlotType (See Table 14-3.)
Access
Read-only
System Slot External Slot Name
Name
systemSlotSlotExternalSlotName
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.8
Description
Defines the external connector name of the system slot.
Syntax
DellString
Access
Read-only
Slot Group
279
System Slot Length
Name
systemSlotLength
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.9
Description
Defines the length of the system slot.
Syntax
DellSystemSlotLength (See Table 14-5.)
Access
Read-only
System Slot Slot ID
Name
systemSlotSlotID
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.10
Description
Defines the slot identification number of the system slot. A zero (0)
indicates that the slot is embedded on the motherboard.
Syntax
DellUnsigned32BitRange
Access
Read-only
System Slot Category
Name
systemSlotCategory
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.11
Description
Defines the system slot category.
Syntax
DellUnsigned32BitRange
Access
Read-only
System Slot Hot-Plug Bus Width
280
Name
systemSlotHotPlugBusWidth
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.12
Description
Defines the bus width of the hot-plug system slot.
Syntax
DellSystemSlotHotPlugBusWidth (See Table 14-7.)
Access
Read-only
Slot Group
System Slot Hot-Plug Slot Speed
Name
systemSlotHotPlugSlotSpeed
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.13
Description
Defines the slot speed in megahertz of the hot-plug system slot.
A zero (0) indicates that the slot speed is unknown.
Syntax
DellUnsigned32BitRange
Access
Read-only
System Slot Hot-Plug Adapter Speed
Name
systemSlotHotPlugAdapterSpeed
Object ID
1.3.6.1.4.1.674.10892.1.1200.10.1.14
Description
Defines the adapter speed in megahertz of the hot-plug system slot.
A zero (0) indicates that the slot speed is unknown.
Syntax
DellUnsigned32BitRange
Access
Read-only
System Slot Variable Values
This section includes definitions for server administrator-specific variable values used in this section.
Table 14-1.
System Slot State Capabilities
Variable Name: DellSystemSlotStateCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
systemSlotHotPlugIsUnknown(1)
The system slot’s capabilities are unknown.
systemSlotHotPlugIsHotPluggableCapable(2)
The system slot supports hot-plug.
systemSlotHotPlugCanBePoweredOn(4)
The system slot power (and corresponding
light-emitting diode [LED]) can be
powered on.
systemSlotHotPlugCanSignalAttention(8)
The system slot attention state
(and corresponding LED) can be set.
systemSlotHotPlugCanSignalPowerFault(16)
Power on fault (and corresponding LED)
can be detected due to a short or
overcurrent.
systemSlotHotPlugCanSignalAdapterPresent(32)
Adapter (card) present in slot (may not be
powered) can be detected.
Slot Group
281
Table 14-1.
System Slot State Capabilities (continued)
Variable Name: DellSystemSlotStateCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
systemSlotHotPlugCanSignalPowerButtonPressed(64) The system slot power button can be
pressed to signal a toggle of the power state.
282
canSupportAllHotPlugCapabilities(126)
The system slot can support all
hot-plug capabilities.
systemSlotHotPlugIsUnknown(1)
The system slot’s capabilities are unknown.
systemSlotCanProvide5Volts(128)
The system slot can provide a
5-volt (V) supply.
systemSlotCanProvide3Point3Volts(256)
The system slot can provide a 3.3-V supply.
systemSlotCanSignalIfShared(512)
The system slot’s opening, if shared with
another slot, can be detected.
systemSlotCanSupportCard16(1024)
The system slot can support
PC Card-16.
systemSlotCanSupportCardBus(2048)
The system slot can support CardBus.
systemSlotCanSupportZoomVideo(4096)
The system slot can support Zoom Video.
systemSlotCanSupportModemRingResume(8192)
The system slot can support modem
ring resume.
systemSlotCanSupportPMESignal(16384)
The system slot can support Power
Management Enable (PME#) signal.
canSupportAllSlotCapabilities(32640)
The system slot can support all
slot capabilities.
Slot Group
Table 14-2.
System Slot State Settings
Variable Name: DellSystemSlotStateSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
systemSlotHotPlugIsUnknown(1)
The system slot’s capabilities are unknown.
systemSlotHotPlugIsHotPluggable(2)
The system slot supports hot-plug.
systemSlotHotPlugIsPoweredOn(4)
The system slot power (and corresponding
LED) can be powered on.
systemSlotHotPlugIsAtAttention(8)
The system slot attention state (and
corresponding LED) can be set.
systemSlotHotPlugIsHotPluggable(2)
The system slot supports hot-plug.
systemSlotHotPlugIsPoweredOn(4)
The system slot power (and corresponding
LED) is on.
systemSlotHotPlugIsAtAttention(8)
The system slot attention state (and
corresponding LED) is on.
systemSlotHotPlugHasPowerFaulted(16)
Power on fault (and corresponding LED)
was detected due to a short or overcurrent.
systemSlotHotPlugAdapterIsPresent(32)
Adapter (card) present in slot (may not be
powered).
systemSlotHotPlugAdapterPresentAndPoweredOn(36) Adapter (card) present in slot and powered.
systemSlotHotPlugPowerButtonPressed(64)
The system slot power button pressed to
signal a toggle of the power state.
systemSlotProvides5Volts(128)
The system slot provides a 5-V supply.
systemSlotProvides3Point3Volts(256)
The system slot provides a 3.3-V supply.
systemSlotIsShared(512)
The slot’s opening is shared with
another slot.
systemSlotSupportsCard16(1024)
The system slot supports PC Card-16.
systemSlotSupportsCardBus(2048)
The system slot supports CardBus.
systemSlotSupportsZoomVideo(4096)
The system slot supports zoom video.
systemSlotSupportsModemRingResume(8192)
The system slot supports modem
ring resume.
systemSlotSupportsPMESignal(16384)
The system slot supports power
management enable (PME#) signal.
supportsPMEand3P3Vand5VandHotPluggable(16770)
The system slot supports power
management enable.
Slot Group
283
Table 14-2.
System Slot State Settings (continued)
Variable Name: DellSystemSlotStateSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
supportsPMEand3P3Vand5VhasAdapterOn(16804)
The system slot supports power
management event (PME), supplies 3.3 V,
and supplies 5 V. The adapter is on.
supportsPMEand3P3Vand5VhasAdapterOnandisHotPlug The system slot supports PME, supplies 3.3 V,
gable(16806)
and supplies 5 V. The adapter is on and the
system slot is hot pluggable.
supportsPMEand3P3VIsSharedand5VhasAdapterOnandi The system slot supports PME, supplies 3.3 V,
sHotPluggable(17316)
supplies 5 V, and shares a slot opening. The
adapter is on and the system slot is
hot pluggable.
Table 14-3.
System Slot Type
Variable Name: DellSystemSlotType
Data Type: Integer
284
Possible Data Values
Meaning of Data Value
systemSlotIsOther(1)
The system slot type is not one of
following:
systemSlotIsUnknown(2)
The system slot type is unknown.
systemSlotIsISA(3)
The system slot is Industry Standard
Architecture (ISA).
systemSlotIsMCA(4)
The system slot is Micro Channel
Architecture (MCA).
systemSlotIsEISA(5)
The system slot is Extended Industry
Standard Architecture (EISA).
systemSlotIsPCI(6)
The system slot is Peripheral Component
Interconnect (PCI).
systemSlotIsPCMCIA(7)
The system slot is compliant with the
Personal Computer Memory Card
International Association (PCMCIA)
standards.
systemSlotIsVLVESA(8)
The system slot is Very Low Voltage
Enterprise System Architecture
(VLVESA).
Slot Group
Table 14-3.
System Slot Type (continued)
Variable Name: DellSystemSlotType
Data Type: Integer
Possible Data Values
Meaning of Data Value
systemSlotIsProprietary(9)
The system slot is proprietary.
systemSlotIsProcessorCard(10)
The system slot is a processor card.
systemSlotIsProprietaryMemory(11)
The system slot is proprietary memory.
systemSlotIsIORiserCard(12)
The system slot is an I/O riser card.
systemSlotIsNuBUS(13)
The system slot is a NuBus.
systemSlotIsPCI66MHz(14)
The system slot is a PCI66MHz.
systemSlotIsAGP(15)
The system slot is an Advanced Graphics
Port (AGP).
systemSlotIsAGP2X(16)
The system slot is an AGP 2x card.
systemSlotIsAGP4X(17)
The system slot is an AGP 4x card.
systemSlotIsPC98C20(18)
The system slot is a PC-98/C20.
systemSlotIsPC98C24(19)
The system slot is a PC-98/C24.
systemSlotIsPC98E(20)
The system slot type is PC-98/E.
systemSlotIsPC98LocalBus(21)
The system slot type is a PC-98 local bus.
systemSlotIsPC98Card(22)
The system slot type is a PC-98 card.
systemSlotIsPCIX(23)
The system slot type is a PCIX card.
systemSlotIsPCIExpress(24)
The system slot type is a PCI Express card.
systemSlotIsAGP8X(25)
The system slot type is an AGP 8x card.
Slot Group
285
Table 14-4.
System Slot Usage
Variable Name: DellSystemSlotUsage
Data Type: Integer
Possible Data Values
Meaning of Data Value
systemSlotUsageIsOther(1)
The system slot usage is not one of following:
systemSlotUsageIsUnknown(2)
The system slot usage is unknown.
systemSlotUsageIsAvailable(3)
The system slot is available.
systemSlotUsageIsInUse(4)
The system slot is in use.
Table 14-5.
System Slot Length
Variable Name: DellSystemSlotLength
Data Type: Integer
Possible Data Values
Meaning of Data Value
systemSlotLengthIsOther(1)
The system slot length is not one of following:
systemSlotLengthIsUnknown(2)
The system slot length is unknown.
systemSlotLengthIsShort(3)
The system slot length is short.
systemSlotLengthIsLong(4)
The system slot length is long.
Table 14-6.
System Slot Category
Variable Name: DellSystemSlotCategory
Data Type: Integer
Possible Data Values
Meaning of Data Value
systemSlotCategoryIsOther(1)
The system slot category is not one of following:
systemSlotCategoryIsUnknown(2)
The system slot category is unknown.
systemSlotCategoryIsBusConnector(3) The system slot is a bus connector.
286
systemSlotCategoryIsPCMCIA(4)
The system slot category is PCMCIA.
systemSlotCategoryIsMotherboard(5)
The system slot is a motherboard.
Slot Group
Table 14-7.
Hot-Plug Bus Width
Variable Name: DellSystemSlotHotPlugBusWidth
Data Type: Integer
Possible Data Values
Meaning of Data Value
busWidthIsOther(1)
The system slot bus width is not one of following:
busWidthIsUnknown(2)
The system slot bus width is unknown.
busWidthIs8bits(3)
The system slot bus width is 8 bits.
busWidthIs16bits(4)
The system slot bus width is 16 bits.
busWidthIs32bits(5)
The system slot bus width is 32 bits.
busWidthIs64bits(6)
The system slot bus width is 64 bits.
busWidthIs128bits(7)
The system slot bus width is 128 bits.
busWidthIs1xOrx1(8)
The system slot bus width is 1x or x1.
busWidthIs2xOrx2(9)
The system slot bus width is 2x or x2.
busWidthIs4xOrx4(10)
The system slot bus width is 4x or x4.
busWidthIs8xOrx8(11)
The system slot bus width is 8x or x8.
busWidthIs12xOrx12(12)
The system slot bus width is 12x or x12.
busWidthIs16xOrx16(13)
The system slot bus width is 16x or x16.
busWidthIs32xOrx32(14)
The system slot bus width is 32x or x32.
NOTE: System slot bus width meanings of type "n bits" are for parallel bus such as PCI.
NOTE: System slot bus width meanings of type "nx or xn" are for serial bus such as PCI Express.
Slot Group
287
288
Slot Group
Memory Group
The Memory Group provides information about the physical memory in your system. Variables in
this group include error correction type, location, and different types of memory use, such as cache,
flash, system, video, and nonvolatile memory.
Physical Memory Tables
The following management information base (MIB) tables define the objects in the Memory Group:
•
Physical Memory Array Table
•
Physical Memory Array Mapped Table
•
Physical Memory Configuration Table
•
Physical Memory Logging Table
•
Redundant Memory Unit Table
•
Physical Memory Card Table
Physical Memory Array Table
The physical memory array is the entire physical memory of a system. The example that follows
shows variable values for a system that has one 128-megabyte (MB) dual in-line memory
module (DIMM):
•
physicalMemoryArrayMaximumSize = 2,097,152 kilobytes (KB) or 2 gigabytes (GB)
•
physicalMemoryArrayTotalNumberSockets = 4 (the example system has four DIMM slots on
the motherboard)
•
physicalMemoryArrayInUseNumberSockets = 1 (there is only one DIMM installed)
The following object sets up the Physical Memory Array Table:
Name
physicalMemoryArrayTable
Object ID
1.3.6.1.4.1.674.10892.1.1300.10
Description
Defines the Physical Memory Array Table.
Syntax
PhysicalMemoryArrayTableEntry
Access
Not accessible
Memory Group
289
Physical Memory Array Table Entry
Name
physicalMemoryArrayTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1
Description
Defines the Physical Memory Array Table entry.
Syntax
PhysicalMemoryArrayTableEntry
Access
Not accessible
Index
physicalMemoryArraychassisIndex, physicalMemoryArrayIndex
Physical Memory Array Chassis Index
Name
physicalMemoryArraychassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Physical Memory Array Index
Name
physicalMemoryArrayIndex
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.2
Description
Defines the index (one-based) of the physical memory array in this chassis.
Syntax
DellObjectRange
Access
Read-only
Physical Memory Array State Capabilities
290
Name
physicalMemoryArrayStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.3
Description
Defines the capabilities of the physical memory array.
Syntax
DellStateCapabilities
Access
Read-only
Memory Group
Physical Memory Array State Settings
Name
physicalMemoryArrayStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.4
Description
Defines the state of the physical memory array.
Syntax
DellStateSettings
Access
read-write
Physical Memory Array Status
Name
physicalMemoryArrayStatus
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.5
Description
Defines the status of the physical memory array.
Syntax
DellStatus
Access
Read-only
Physical Memory Array Use
Name
physicalMemoryArrayUse
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.6
Description
Defines the use of the physical memory array.
Syntax
DellPhysicalMemoryArrayUse (See Table 15-2.)
Access
Read-only
Physical Memory Array Error Checking and Correcting (ECC) Type
Name
physicalMemoryArrayECCType
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.7
Description
Defines the ECC type used by the physical memory array.
Syntax
DellPhysicalMemoryArrayECCType (See Table 15-2.)
Access
Read-only
Memory Group
291
Physical Memory Array Location
Name
physicalMemoryArrayLocation
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.8
Description
Defines the location of the physical memory array.
Syntax
DellPhysicalMemoryArrayLocation (See Table 15-1.)
Access
Read-only
Physical Memory Array Maximum Size
Name
physicalMemoryArrayMaximumSize
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.9
Description
Defines the size in KB of the physical memory array.
Syntax
DellUnsigned32BitRange
Access
Read-only
Physical Memory Array Total Number Sockets
Name
physicalMemoryArrayTotalNumberSockets
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.10
Description
Defines the total number of memory sockets available for the
physical memory array.
Syntax
DellUnsigned32BitRange
Access
Read-only
Physical Memory Array In Use Number Sockets
292
Name
physicalMemoryArrayInUseNumberSockets
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.11
Description
Defines the total number of memory sockets in use by the physical
memory array.
Syntax
DellUnsigned32BitRange
Access
Read-only
Memory Group
Physical Memory Array ECC Error Nonrecoverable Threshold
Name
physicalMemoryArrayECCErrorNonRecoverbeThreshold
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.12
Description
Defines the value of the physical memory array Error Checking and
Correction (ECC) error nonrecoverable threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Physical Memory Array ECC Error Critical Threshold
Name
physicalMemoryArrayECCErrorCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.13
Description
Defines the value of the physical memory array ECC error critical threshold.
Syntax
DellSigned32BitRange
Access
Read-only
Physical Memory Array ECC Error Noncritical Threshold
Name
physicalMemoryArrayECCErrorNonCriticalThreshold
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.14
Description
Defines the value of the physical memory array ECC error noncritical threshold.
Syntax
DellSigned32BitRange
Access
read-write
Physical Memory Array Redundant Memory Unit Index Reference
Name
physicalMemoryArrayRedundantMemoryUnitIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1300.10.1.15
Description
Defines the index to the associated Redundant Memory Unit in this chassis.
Syntax
DellObjectRange
Access
Read-only
Memory Group
293
Physical Memory Array Mapped Table
The physical memory array is divided into memory array mapped addresses.
The following object sets up the Physical Memory Array Mapped Table:
Name
physicalMemoryArrayMappedTable
Object ID
1.3.6.1.4.1.674.10892.1.1300.20
Description
Defines the Physical Memory Array Mapped Table.
Syntax
PhysicalMemoryArrayMappedTableEntry
Access
Not accessible
Physical Memory Array Mapped Table Entry
Name
PhysicalMemoryArrayMappedTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1300.20.1
Description
Defines the Physical Memory Array Mapped Table entry.
Syntax
PhysicalMemoryArrayMappedTableEntry
Access
Not accessible
Index
physicalMemoryArrayMappedchassisIndex,
physicalMemoryArrayMappedIndex
Physical Memory Array Mapped Chassis Index
Name
physicalMemoryArrayMappedchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1300.20.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Physical Memory Array Mapped Index
294
Name
physicalMemoryArrayMappedIndex
Object ID
1.3.6.1.4.1.674.10892.1.1300.20.1.2
Description
Defines the index (one-based) of the memory array mapped address
in this chassis.
Syntax
DellObjectRange
Access
Read-only
Memory Group
Physical Memory Array Mapped State Capabilities
Name
physicalMemoryArrayMappedStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1300.20.1.3
Description
Defines the capabilities of the memory array mapped address.
Syntax
DellStateCapabilities
Access
Read-only
Physical Memory Array Mapped State Settings
Name
physicalMemoryArrayMappedStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1300.20.1.4
Description
Defines the state of the memory array mapped address.
Syntax
DellStateSettings
Access
Read-write
Physical Memory Array Mapped Status
Name
physicalMemoryArrayMappedStatus
Object ID
1.3.6.1.4.1.674.10892.1.1300.20.1.5
Description
Defines the status of the memory array mapped address.
Syntax
DellStatus
Access
Read-only
Physical Memory Array Index Reference
Name
physicalMemoryArrayIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1300.20.1.6
Description
Defines the index to the associated physical memory array in this chassis.
Syntax
DellObjectRange
Access
Read-only
Memory Group
295
Physical Memory Array Mapped Starting Address
Name
physicalMemoryArrayMappedStartingAddress
Object ID
1.3.6.1.4.1.674.10892.1.1300.20.1.7
Description
Defines the physical starting address in KB of the memory array
mapped address.
Syntax
DellUnsigned64BitRange
Access
Read-only
Physical Memory Array Mapped Ending Address
Name
physicalMemoryArrayMappedEndingAddress
Object ID
1.3.6.1.4.1.674.10892.1.1300.20.1.8
Description
Defines the physical ending address in KB of the memory array
mapped address.
Syntax
DellUnsigned64BitRange
Access
Read-only
Physical Memory Array Mapped Partition Width
296
Name
physicalMemoryArrayMappedPartitionWidth
Object ID
1.3.6.1.4.1.674.10892.1.1300.20.1.9
Description
Defines the number of memory devices that form a single row in the
memory array mapped address. A zero (0) indicates that the number
is unknown.
Syntax
DellUnsigned32BitRange
Access
Read-only
Memory Group
Physical Memory Configuration Table
This table defines how the physical memory of a system chassis is set up, for example, which redundant
memory types are supported and whether redundant memory is active.
The following object sets up the Physical Memory Configuration Table:
Name
physicalMemoryConfigTable
Object ID
1.3.6.1.4.1.674.10892.1.1300.30
Description
Defines the Physical Memory Configuration Table.
Syntax
SEQUENCE OF PhysicalMemoryConfigTableEntry
Access
Not accessible
Physical Memory Configuration Table Entry
Name
physicalMemoryConfigTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1300.30.1
Description
Defines the Physical Memory Configuration Table entry.
Syntax
PhysicalMemoryConfigTableEntry
Access
Not accessible
Index
physicalMemoryConfigChassisIndex, physicalMemoryConfigIndex
Physical Memory Configuration Chassis Index
Name
physicalMemoryConfigChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1300.30.1.1
Description
Defines the index (one-based) of the chassis associated with the
physical memory configuration.
Syntax
DellObjectRange
Access
Read-only
Physical Memory Configuration Index
Name
physicalMemoryConfigIndex
Object ID
1.3.6.1.4.1.674.10892.1.1300.30.1.2
Description
Defines the index (one-based) of the physical memory
configuration.
Syntax
DellObjectRange
Access
Read-only
Memory Group
297
Physical Memory Configuration State Capabilities
Name
physicalMemoryConfigStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1300.30.1.3
Description
Defines the state capabilities of the physical memory configuration.
Syntax
DellPhysicalMemoryConfigStateCapabilities
Access
Read-only
Physical Memory Configuration State Settings
Name
physicalMemoryConfigStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1300.30.1.4
Description
Defines the state settings of the physical memory configuration.
Syntax
DellPhysicalMemoryConfigStateSettings
Access
Read-write
Physical Memory Configuration Status
Name
physicalMemoryConfigStatus
Object ID
1.3.6.1.4.1.674.10892.1.1300.30.1.5
Description
Defines the status of the physical memory configuration.
Syntax
DellStatus
Access
Read-only
Physical Memory Configuration Redundant Capabilities
298
Name
physicalMemoryConfigRedundantCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1300.30.1.6
Description
Defines the redundant capabilities of the physical memory.
Syntax
DellPhysicalMemoryConfigRedundantCapabilities
Access
Read-only
Memory Group
Physical Memory Configuration Redundant Settings
Name
physicalMemoryConfigRedundantSettings
Object ID
1.3.6.1.4.1.674.10892.1.1300.30.1.7
Description
Defines the redundant settings of the physical memory.
Syntax
DellPhysicalMemoryConfigRedundantSettings
Access
Read-write
Physical Memory Logging Table
This table defines the conditions for logging system memory events.
The following object sets up the Physical Memory Logging Table:
Name
physicalMemoryLoggingTable
Object ID
1.3.6.1.4.1.674.10892.1.1300.40
Description
Defines the Physical Memory Logging Table.
Syntax
SEQUENCE OF PhysicalMemoryLoggingTableEntry
Access
Not accessible
Physical Memory Logging Table Entry
Name
physicalMemoryLoggingTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1300.40.1
Description
Defines the Physical Memory Logging Table entry.
Syntax
PhysicalMemoryLoggingTableEntry
Access
Not accessible
Index
physicalMemoryLoggingChassisIndex,
physicalMemoryLoggingIndex
Physical Memory Logging Chassis Index
Name
physicalMemoryLoggingChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1300.40.1.1
Description
Defines the index (one-based) of the chassis associated with the
physical memory logging.
Syntax
DellObjectRange
Access
Read-only
Memory Group
299
Physical Memory Logging Index
Name
physicalMemoryLoggingIndex
Object ID
1.3.6.1.4.1.674.10892.1.1300.40.1.2
Description
Defines the index (one-based) of the physical memory logging.
Syntax
DellObjectRange
Access
Read-only
Physical Memory Logging Capabilities
Name
physicalMemoryLoggingCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1300.40.1.3
Description
Defines the capabilities of the physical memory logging.
Syntax
DellPhysicalMemoryLoggingCapabilities
Access
Read-only
Physical Memory Logging Settings
Name
physicalMemoryLoggingSettings
Object ID
1.3.6.1.4.1.674.10892.1.1300.40.1.4
Description
Defines the settings of the physical memory logging.
Syntax
DellPhysicalMemoryLoggingSettings
Access
Read-write
Physical Memory Logging Status
300
Name
physicalMemoryLoggingStatus
Object ID
1.3.6.1.4.1.674.10892.1.1300.40.1.5
Description
Defines the status of the physical memory logging.
Syntax
DellStatus
Access
Read-only
Memory Group
Redundant Memory Unit Table
This table reports the status of redundant memory within a particular system chassis.
The following object sets up the Redundant Memory Unit Table:
Name
redundantMemoryUnitTable
Object ID
1.3.6.1.4.1.674.10892.1.1300.50
Description
Defines the Redundant Memory Unit Table.
Syntax
SEQUENCE OF RedundantMemoryUnitTableEntry
Access
Not accessible
Redundant Memory Unit Table Entry
Name
redundantMemoryUnitTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1300.50.1
Description
Defines the Redundant Memory Unit Table entry.
Syntax
RedundantMemoryUnitTableEntry
Access
Not accessible
Index
redundantMemoryUnitChassisIndex, redundantMemoryUnitIndex
Redundant Memory Unit Chassis Index
Name
redundantMemoryUnitChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1300.50.1.1
Description
Defines the index (one-based) of the chassis associated with the
redundant memory unit.
Syntax
DellObjectRange
Access
Read-only
Redundant Memory Unit Index
Name
redundantMemoryUnitIndex
Object ID
1.3.6.1.4.1.674.10892.1.1300.50.1.2
Description
Defines the index (one-based) of the redundant memory unit.
Syntax
DellObjectRange
Access
Read-only
Memory Group
301
Redundant Memory Unit State Capabilities
Name
redundantMemoryUnitStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1300.50.1.3
Description
Defines the state capabilities of the redundant memory unit.
Syntax
DellStateCapabilities
Access
Read-only
Redundant Memory Unit State Settings
Name
redundantMemoryUnitStatesettings
Object ID
1.3.6.1.4.1.674.10892.1.1300.50.1.4
Description
Defines the state settings of the redundant memory unit.
Syntax
DellStateSettings
Access
Read-write
Redundant Memory Unit Redundancy Status
Name
redundantMemoryUnitRedundancyStatus
Object ID
1.3.6.1.4.1.674.10892.1.1300.50.1.5
Description
Defines the redundancy status of the redundant memory unit.
Syntax
DellStatusRedundancy
Access
Read-only
Redundant Memory Unit Name
302
Name
redundantMemoryUnitName
Object ID
1.3.6.1.4.1.674.10892.1.1300.50.1.6
Description
Defines the name of the redundant memory unit.
Syntax
DellString
Access
Read-only
Memory Group
Redundant Memory Unit Status
Name
redundantMemoryUnitStatus
Object ID
1.3.6.1.4.1.674.10892.1.1300.50.1.7
Description
Defines the status of the redundant memory unit.
Syntax
DellStatus
Access
Read-only
Physical Memory Card Table
This table defines the name of the memory card, the total number of device slots present on the
memory card, and the number of memory device slots in use on the memory card.
The following objects set up the Physical Memory Card Table:
Physical Memory Card Table
Name
physicalMemoryCardTable
Object ID
1.3.6.1.4.1.674.10892.1.1300.60
Description
Defines the Physical Memory Card Table.
Syntax
SEQUENCE OF PhysicalMemoryCardTableEntry
Access
Not accessible
Physical Memory Card Table Entry
Name
physicalMemoryCardTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1300.60.1
Description
Defines the Physical Memory Card Table Entry.
Syntax
PhysicalMemoryCardTableEntry
Access
Not accessible
Index
physicalMemoryCardChassisIndex, physicalMemoryCardIndex
Physical Memory Card Chassis Index
Name
physicalMemoryCardChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1300.60.1.1
Description
Defines the index (one-based) of the associated chassis.
Syntax
DellObjectRange
Access
Read-only
Memory Group
303
Physical Memory Card Index
Name
physicalMemoryCardIndex
Object ID
1.3.6.1.4.1.674.10892.1.1300.60.1.2
Description
Defines the index (one-based) of the Physical Memory Card.
Syntax
DellObjectRange
Access
Read-only
Physical Memory Card State Capabilities
Name
physicalMemoryCardStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1300.60.1.3
Description
Defines the state capabilities of the Physical Memory Card.
Syntax
DellStateCapabilities
Access
Read-only
Physical Memory Card State Settings
Name
physicalMemoryCardStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1300.60.1.4
Description
Defines the state settings of the Physical Memory Card.
Syntax
DellStateSettings
Access
Read-write
Physical Memory Card Status
304
Name
physicalMemoryCardStatus
Object ID
1.3.6.1.4.1.674.10892.1.1300.60.1.5
Description
Defines the status of the Physical Memory Card.
Syntax
DellStatus
Access
Read-only
Memory Group
Physical Memory Card Name
Name
physicalMemoryCardName
Object ID
1.3.6.1.4.1.674.10892.1.1300.60.1.6
Description
Defines the name of the Physical Memory Card.
Syntax
DellString
Access
Read-only
Physical Memory Card Total Number Sockets
Name
physicalMemoryCardTotalNumberSockets
Object ID
1.3.6.1.4.1.674.10892.1.1300.60.1.7
Description
Defines the total number of memory sockets available on the
Physical Memory Card. 2,147,483,647 indicates an unknown number
of sockets.
Syntax
DellUnsigned32BitRange
Access
Read-only
Physical Memory Card In Use Number Sockets
Name
physicalMemoryCardInUseNumberSockets
Object ID
1.3.6.1.4.1.674.10892.1.1300.60.1.8
Description
Defines the number of memory sockets in use on the Physical
Memory Card. Zero indicates that the Physical Memory Card is
not installed or has a configuration error.
Syntax
DellUnsigned32BitRange
Access
Read-only
Physical Memory Card Physical Memory Array Index Reference
Name
physicalMemoryCardPhyMemArrayIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1300.60.1.9
Description
Defines the index (one-based) of the Physical Memory Array Table
entry for the physical memory array with the same chassis index that
this physical memory card is associated with.
Syntax
DellObjectRange
Access
Read-only
Memory Group
305
Memory Group Variable Values
This section includes definitions for server administrator-specific variable values used in this section.
Table 15-1.
Physical Memory Array Location
Variable Name: DellPhysicalMemoryArrayLocation
Data Type: Integer
Possible Data Values
Meaning of Data Value
memoryArrayLocationIsOther(1)
The memory array location is not one of the following:
memoryArrayUseIsUnknown(2)
The memory array use is unknown.
memoryArrayUseIsSystemMemory(3)
The memory array is system memory.
memoryArrayUseIsVideoMemory(4)
The memory array is video memory.
memoryArrayUseIsFLASHMemory(5)
The memory array is FLASH memory.
memoryArrayUseIsNonVolatileRAMMemory(6) The memory array is nonvolatile RAM.
306
memoryArrayUseIsCacheMemory(7)
The memory array is cache memory.
memoryArrayLocationIsPCMCIA(8)
The memory array location is a Personal Computer
Memory Card International Association (PCMCIA)
option card.
memoryArrayLocationIsProprietary(9)
The memory array location is a proprietary option card.
memoryArrayLocationIsNUBUS(10)
The memory array location is a NuBus bus.
memoryArrayLocationIsPC98C20(11)
The memory array location is a PC-98/C20 option card.
memoryArrayLocationIsPC98C24(12)
The memory array location is a PC-98/C24 option card.
memoryArrayLocationIsPC98E(13)
The memory array location is a PC-98/E option card.
memoryArrayLocationIsPC98LocalBus(14)
The memory array location is a PC-98/Local bus
option card.
memoryArrayLocationIsPC98Card(15)
The memory array location is a PC-98/Card slot
option card.
Memory Group
Table 15-2.
Physical Memory Array ECC Type Definitions
Variable Name: DellPhysicalMemoryArrayECCType
Data Type: Integer
Possible Data Values
Meaning of Data Value
memoryArrayECCTypeIsOther(1)
There is not one of the following:
memoryArrayECCTypeIsUnknown(2)
The memory array ECC type is unknown.
memoryArrayECCTypeIsNone(3)
The memory array ECC type is none.
memoryArrayECCTypeIsParity(4)
The memory array ECC type is parity.
memoryArrayECCTypeIsSingleBitECC(5) The memory array ECC type is Correctable Memory
Event ECC.
memoryArrayECCTypeIsMultiBitECC(6) The memory array ECC type is Uncorrectable Memory
Event ECC.
memoryArrayECCTypeIsCRC(7)
Table 15-3.
The memory array ECC type is CRC.
Physical Memory Configuration State Capabilities
Variable Name: DellPhysicalMemoryConfigStateCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
If set to 0 (zero)
There are no state capabilities.
unknownCapabilities(1)
State capabilities are unknown.
enableCapable(2)
Object enable/disable is supported.
notReadyCapable(4)
Object "not ready" is supported.
Memory Group
307
Table 15-4.
Physical Memory Configuration State Settings
Variable Name: DellPhysicalMemoryConfigStateSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
If set to 0 (zero)
There are no state settings.
unknown(1)
State settings are unknown.
enabled(2)
Object is disabled (offline) 0, or enabled (online) 1.
notReady(4)
Object "not ready."
redundantMemoryIsActive(8)
Redundant memory is active (in use)
enabledAndRedundantMemoryIsActive(10) Redundant memory is enabled and in use.
Table 15-5.
Physical Memory Configuration Redundant Capabilities
Variable Name: DellPhysicalMemoryConfigRedundantCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
If set to 0 (zero)
There are no redundant memory capabilities.
unknownCapabilities(1)
Redundant capabilities are unknown.
The redundant capabilities are:
308
spareCapable(2)
Spare redundant memory feature is supported.
mirrorCapable(4)
Mirror redundant memory feature is supported.
spareAndMirrorCapable(6)
Spare and mirror redundant memory features are
supported.
raidCapable(8)
Redundant Array of Independent disks (RAID)
redundant memory feature is supported.
Memory Group
Table 15-6.
Physical Memory Configuration Redundant Settings
Variable Name: DellPhysicalMemoryConfigRedundantSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
If set to 0 (zero)
There are no redundant memory settings enabled.
unknown(1)
Redundant settings are unknown.
The following redundant settings are mutually exclusive:
spareEnabled(2)
Spare redundant memory feature is enabled.
mirrorEnabled(4)
Mirror redundant memory feature is enabled.
raidEnabled(8)
RAID redundant memory feature is enabled.
Table 15-7.
Physical Memory Logging Capabilities
Variable Name: DellPhysicalMemoryLoggingCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
If set to 0 (zero)
There are no logging capabilities.
unknown Capabilities(1)
Logging capabilities are unknown.
The logging capabilities are:
enableCapable(2)
Table 15-8.
Logging enable/disable using Simple Network
Management Protocol (SNMP) is supported.
Physical Memory Logging Settings
Variable Name: DellPhysicalMemoryLoggingSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
If set to 0 (zero)
There are no logging settings enabled.
unknown Capabilities(1)
Logging capabilities are unknown.
The logging settings are:
enabled(2)
Logging is disabled (0), or enabled (1).
Memory Group
309
310
Memory Group
BIOS Setup Control Group
Basic Input/Output System (BIOS) Setup Control Group variables provide information about the
functions that the BIOS performs in your system. This management information base (MIB) group
includes variables for the boot sequence, speakers, diskettes, ports, network interface controllers (NICs),
and the Wakeup on local area network (LAN) feature.
BIOS Group Tables
The objects in this group define the BIOS control of devices and controller cards that are typically
present in a system. The following MIB tables define the BIOS Setup Control Group:
•
BIOS Setup Control Table
•
SCSI Control Table
•
Parallel Port Control Table
•
Serial Port Control Table
•
USB Control Table
•
IDE Control Table
•
Diskette Control Table
•
Network Interface Control Table
BIOS Setup Control Table
Name
biosSetUpControlTable
Object ID
1.3.6.1.4.1.674.10892.1.1400.10
Description
Defines the set of single devices in a chassis controlled by the BIOS.
Syntax
BiosSetUpControlTableEntry
Access
Not accessible
BIOS Setup Control Group
311
BIOS Setup Control Table Entry
Name
biosSetUpControlTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1
Description
Defines the BIOS Control Device Table entry.
Syntax
BiosSetUpControlTableEntry
Access
Not accessible
Index
biosSetUpControlchassisIndex
BIOS Setup Control Chassis Index
Name
biosSetUpControlchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
BIOS Setup Control (BSUC) Pointing Device Control Capabilities
Name
bSUCpointingDeviceControlCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.2
Description
Defines the capabilities of the pointing device.
Syntax
DellStateCapabilities
Access
Read-only
BIOS Setup Control Pointing Device Control Settings
312
Name
bSUCpointingDeviceControlSettings
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.3
Description
Defines the state of the pointing device.
Syntax
DellStateSettings
Access
Read-write
BIOS Setup Control Group
BIOS Setup Control Pointing Device Control Status
Name
bSUCpointingDeviceControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.4
Description
Defines the status of the pointing device.
Syntax
DellStatus
Access
Read-only
BIOS Setup Control Pointing Device Control Name
Name
bSUCpointingDeviceControlName
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.5
Description
Defines the setup BIOS name of the pointing device.
Syntax
DellString
Access
Read-only
BIOS Setup Control Numeric Lock Control Capabilities
Name
bSUCnumLockControlCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.6
Description
Defines the capabilities of the numeric lock.
Syntax
DellStateCapabilities
Access
Read-only
BIOS Setup Control Numeric Lock Control Settings
Name
bSUCnumLockControlSettings
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.7
Description
Defines the state of the numeric lock.
Syntax
DellStateSettings
Access
Read-only
BIOS Setup Control Group
313
BIOS Setup Control Numeric Lock Control Status
Name
bSUCnumLockControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.8
Description
Defines the status of the numeric lock.
Syntax
DellStatus
Access
Read-only
BIOS Setup Control Numeric Lock Control Name
Name
bSUCnumLockControlName
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.9
Description
Defines the setup BIOS name of the numeric lock.
Syntax
DellString
Access
Read-only
BIOS Setup Control Processor Serial Number Control Capabilities
Name
bSUCprocessorSerialNumberControlCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.10
Description
Defines if the processor serial number can be returned.
Syntax
DellStateCapabilities
Access
Read-only
BIOS Setup Control Processor Serial Number Control Settings
314
Name
bSUCprocessorSerialNumberControlSettings
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.11
Description
Defines the state of the processor serial number.
Syntax
DellStateSettings
Access
Read-only
BIOS Setup Control Group
BIOS Setup Control Processor Serial Number Control Status
Name
bSUCprocessorSerialNumberControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.12
Description
Defines the status of the processor serial number.
Syntax
DellStatus
Access
Read-only
BIOS Setup Control Processor Serial Number Control Name
Name
bSUCprocessorSerialNumberControlName
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.13
Description
Defines the setup BIOS name of the processor serial number.
Syntax
DellString
Access
Read-write
BIOS Setup Control Speaker Control Capabilities Unique
Name
bSUCspeakerControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.14
Description
Defines the capabilities of the speaker control.
Syntax
DellSpeakerControlCapabilitiesUnique (See Table 16-1.)
Access
Read-only
BIOS Setup Control Speaker Control Settings Unique
Name
bSUCspeakerControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.15
Description
Defines the settings available for speaker control.
Syntax
DellSpeakerControlSettingsUnique (See Table 16-2.)
Access
Read-only
BIOS Setup Control Group
315
BIOS Setup Control Speaker Control Status
Name
bSUCspeakerControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.16
Description
Defines the status of speaker control.
Syntax
DellStatus
Access
Read-only
BIOS Setup Control Speaker Control Name
Name
bSUCspeakerControlName
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.17
Description
Defines the setup BIOS name of the speaker control.
Syntax
DellString
Access
Read-only
BIOS Setup Control NIF Wakeup on LAN Control Capabilities Unique
Name
bSUCnIFwakeonLanControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.18
Description
Defines the defines the capabilities of the network interface function (NIF)
Wakeup on LAN.
Syntax
DellNIFwakeonLanControlCapabilitiesUnique (SeeTable 16-4.)
Access
Read-only
BIOS Setup Control NIF Wakeup on LAN Control Settings Unique
316
Name
bSUCnIFwakeonLanControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.19
Description
Defines the state of the NIF Wakeup on LAN.
Syntax
DellNIFwakeonLanControlSettingsUnique (See Table 16-4.)
Access
Read-only
BIOS Setup Control Group
BIOS Setup Control NIF Wakeup on LAN Control Status
Name
bSUCnIFwakeonLanControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.20
Description
Defines the status of the NIF Wakeup on LAN.
Syntax
DellStatus
Access
Read-only
BIOS Setup Control NIF Wakeup on LAN Control Name
Name
bSUCnIFwakeonLanControlName
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.21
Description
Defines the setup BIOS name of the NIF Wakeup on LAN.
Syntax
DellString
Access
Read-only
BIOS Setup Control Boot Sequence Control Capabilities Unique
Name
bSUCbootSequenceControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.22
Description
Defines the capabilities of the boot sequence.
Syntax
DellBootSequenceControlCapabilitiesUnique (SeeTable 16-5.)
Access
Read-only
BIOS Setup Control Boot Sequence Control Settings Unique
Name
DellBootSequenceControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.23
Description
Defines the state of the boot sequence.
Syntax
DellBootSequenceControlSettingsUnique (SeeTable 16-6.)
Access
Read-only
BIOS Setup Control Group
317
BIOS Setup Control Boot Sequence Control Status
Name
bSUCbootSequenceControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.24
Description
Defines the status of the boot sequence.
Syntax
DellStatus
Access
Read-only
BIOS Setup Control Boot Sequence Control Name
Name
bSUCbootSequenceControlName
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.25
Description
Defines the control name of the boot sequence.
Syntax
DellString
Access
Read-only
BIOS Setup Control Administrator Password Control Capabilities Unique
Name
bSUCadministratorPasswordControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.26
Description
Defines the capabilities of the administrator password control.
Syntax
DellBIOSPasswordControlCapabilitiesUnique
Access
Read-only
BIOS Setup Control Administrator Password Control Settings Unique
318
Name
bSUCadministratorPasswordControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.27
Description
Defines the settings for administrator password control.
Syntax
DellBIOSPasswordControlSettingsUnique (See Table 16-9.)
Access
Read-write
BIOS Setup Control Group
BIOS Setup Control Administrator Password Control Status
Name
bSUCadministratorPasswordControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.28
Description
Defines the status for administrator password control.
Syntax
DellStatus
Access
Read-only
BIOS Setup Control Administrator Password Verify Name
Name
bSUCadministratorPasswordVerifyName
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.29
Description
Defines the setup BIOS name for the current administrator password.
Syntax
DellString
Access
Read-write
BIOS Setup Control Administrator Password New Password Name
Name
bSUCadministratorPasswordNewPasswordName
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.30
Description
Defines the setup BIOS name of the new administrator password.
To set a new administrator password, you must have successfully set
the current administrator password immediately preceding this
password change.
Syntax
DellString
Access
Read-write
BIOS Control Setup User Password Control Capabilities Unique
Name
bSUCuserPasswordControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.31
Description
Defines the capabilities of user password control.
Syntax
DellBIOSPasswordControlCapabilitiesUnique
Access
Read-only
BIOS Setup Control Group
319
BIOS Control Setup User Password Control Settings Unique
Name
bSUCuserPasswordControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.32
Description
Defines the control settings for user password control.
Syntax
DellBIOSPasswordControlSettingsUnique (See Table 16-9.)
Access
Read-write
BIOS Control Setup User Password Control Status
Name
bSUCuserPasswordControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.33
Description
Defines the status of the user password control.
Syntax
DellStatus
Access
Read-only
BIOS Control Setup User Password Verify Name
Name
bSUCuserPasswordVerifyName
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.34
Description
Defines the setup BIOS name of the current user password.
Syntax
DellString
Access
Read-write
BIOS Control Setup User Password New Password Name
320
Name
bSUCuserPasswordNewPasswordName
Object ID
1.3.6.1.4.1.674.10892.1.1400.10.1.35
Description
Defines the setup BIOS name of the new user password. To set a new
user password, a you must have successfully set the current user
password immediately preceding this password change.
Syntax
DellString
Access
Read-write
BIOS Setup Control Group
SCSI Control Table
Name
sCSIControlTable
Object ID
1.3.6.1.4.1.674.10892.1.1400.20
Description
Defines the Small Computer System Interface (SCSI) Control Table.
Syntax
SCSIControlTableEntry
Access
Not accessible
SCSI Control Table Entry
Name
sCSIControlTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1400.20.1
Description
Defines the SCSI Control Table entry.
Syntax
SCSIControlTableEntry
Access
Not accessible
Index
sCSIControlchassisIndex, sCSIControlIndex
SCSI Control Chassis Index
Name
sCSIControlchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.20.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
SCSI Control Index
Name
sCSIControlIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.20.1.2
Description
Defines the index (one-based) of the SCSI controller in this chassis.
Syntax
DellObjectRange
Access
Read-only
BIOS Setup Control Group
321
SCSI Control Capabilities
Name
sCSIControlCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1400.20.1.3
Description
Defines the capabilities of the SCSI controller.
Syntax
DellStateCapabilities
Access
Read-only
SCSI Control Settings
Name
sCSIControlSettings
Object ID
1.3.6.1.4.1.674.10892.1.1400.20.1.4
Description
Defines the state of the SCSI controller.
Syntax
DellStateSettings
Access
Read-only
SCSI Control Status
Name
sCSIControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.20.1.5
Description
Defines the status of the SCSI controller.
Syntax
DellStatus
Access
Read-only
SCSI Control Name
322
Name
sCSIControlName
Object ID
1.3.6.1.4.1.674.10892.1.1400.20.1.6
Description
Defines the setup BIOS name of the SCSI controller.
Syntax
DellString
Access
Read-only
BIOS Setup Control Group
Parallel Port Control Table
Name
parallelPortControlTable
Object ID
1.3.6.1.4.1.674.10892.1.1400.30
Description
Defines the Parallel Port Control Table.
Syntax
ParallelPortControlTableEntry
Access
Not accessible
Parallel Port Control Table Entry
Name
parallelPortControlTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1400.30.1
Description
Defines the Parallel Port Control Table entry.
Syntax
ParallelPortControlTableEntry
Access
Not accessible
Index
parallelPortControlchassisIndex, parallelPortControlIndex
Parallel Port Control Chassis Index
Name
parallelPortControlchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.30.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Parallel Port Control Index
Name
parallelPortControlIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.30.1.2
Description
Defines the index (one-based) of the parallel port in this chassis.
Syntax
DellObjectRange
Access
Read-only
BIOS Setup Control Group
323
Parallel Port Control Capabilities Unique
Name
parallelPortControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.30.1.3
Description
Defines the capabilities of the parallel port.
Syntax
DellParallelPortControlCapabilitiesUnique (See Table 16-10.)
Access
Read-only
Parallel Port Control Settings Unique
Name
parallelPortControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.30.1.4
Description
Defines the state of the parallel port.
Syntax
DellParallelPortControlSettingsUnique (See Table 16-11.)
Access
Read-only
Parallel Port Control Status
Name
parallelPortControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.30.1.5
Description
Defines the status of the parallel port.
Syntax
DellStatus
Access
Read-only
Parallel Port Control Name
324
Name
parallelPortControlName
Object ID
1.3.6.1.4.1.674.10892.1.1400.30.1.6
Description
Defines the setup BIOS name of the parallel port.
Syntax
DellString
Access
Read-only
BIOS Setup Control Group
Parallel Port Control Mode Capabilities Unique
Name
parallelPortControlModeCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.30.1.7
Description
Defines the mode capabilities of the parallel port.
Syntax
DellParallelPortControlModeCapabilitiesUnique (See Table 16-12.)
Access
Read-only
Parallel Port Control Mode Settings Unique
Name
parallelPortControlModeSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.30.1.8
Description
Defines the mode settings of the parallel port.
Syntax
DellParallelPortControlModeSettingsUnique (See Table 16-12.)
Access
Read-write
Serial Port Control Table
Name
serialPortControlTable
Object ID
1.3.6.1.4.1.674.10892.1.1400.40
Description
Defines the Serial Port Control Table.
Syntax
SerialPortControlTableEntry
Access
Not accessible
Serial Port Control Table Entry
Name
serialPortControlTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1400.40.1
Description
Defines the Serial Port Control Table entry.
Syntax
SerialPortControlTableEntry
Access
Not accessible
Index
serialPortControlchassisIndex, serialPortControlIndex
BIOS Setup Control Group
325
Serial Port Control Chassis Index
Name
serialPortControlchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.40.1.1
Description
Defines index (one-based) of this chassis.
Syntax
DellObjectRange
Access
read-only
Serial Port Control Index
Name
serialPortControlIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.40.1.2
Description
Defines the index (one-based) of the serial port in this chassis.
Syntax
DellObjectRange
Access
read-only
Serial Port Control Capabilities Unique
Name
serialPortControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.40.1.3
Description
Defines the capabilities of the serial port.
Syntax
DellSerialPortControlCapabilitiesUnique (See Table 16-13.)
Access
Read-only
Serial Port Control Settings Unique
326
Name
serialPortControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.40.1.4
Description
Defines the settings of the serial port.
Syntax
DellSerialPortControlSettingsUnique (See Table 16-14.)
Access
Read-only
BIOS Setup Control Group
Serial Port Control Status
Name
serialPortControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.40.1.5
Description
Defines the status of the serial port.
Syntax
DellStatus
Access
Read-only
Serial Port Control Name
Name
serialPortControlName
Object ID
1.3.6.1.4.1.674.10892.1.1400.40.1.6
Description
Defines the setup BIOS name of the serial port.
Syntax
DellString
Access
Read-only
USB Control Table
These objects enable you to track the attributes of your Universal Serial Bus (USB).
Name
usbControlTable
Object ID
1.3.6.1.4.1.674.10892.1.1400.50
Description
Defines the USB Table.
Syntax
UsbControlTableEntry
Access
Not accessible
USB Control Table Entry
Name
usbControlTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1400.50.1
Description
Defines the USB Table entry.
Syntax
UsbControlTableEntry
Access
Not accessible
Index
usbControlchassisIndex, usbControlIndex
BIOS Setup Control Group
327
USB Control Chassis Index
Name
usbControlchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.50.1.1
Description
Defines index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
USB Control Index
Name
usbControlIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.50.1.2
Description
Defines the index (one-based) of the USB in this chassis.
Syntax
DellObjectRange
Access
Read-only
USB Control Capabilities
Name
usbControlCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1400.50.1.3
Description
Defines the capabilities of the USB.
Syntax
DellStateCapabilities
Access
Read-only
USB Control Settings
328
Name
usbControlSettings
Object ID
1.3.6.1.4.1.674.10892.1.1400.50.1.4
Description
Defines the control settings for the USB.
Syntax
DellStateSettings
Access
Read-only
BIOS Setup Control Group
USB Control Status
Name
usbControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.50.1.5
Description
Defines the status of the USB.
Syntax
DellStatus
Access
Read-only
USB Control Name
Name
usbControlName
Object ID
1.3.6.1.4.1.674.10892.1.1400.50.1.6
Description
Defines the setup BIOS name of the USB.
Syntax
DellString
Access
Read-only
IDE Control Table
These objects enable you to track the attributes of Integrated Device Electronics (IDE) controller cards
in your system.
Name
ideControlTable
Object ID
1.3.6.1.4.1.674.10892.1.1400.60
Description
Defines the IDE Control Table.
Syntax
IdeControlTableEntry
Access
Not accessible
IDE Control Table Entry
Name
ideControlTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1400.60.1
Description
Defines the IDE Control Table entry.
Syntax
IdeControlTableEntry
Access
Not accessible
Index
ideControlchassisIndex, ideControlIndex
BIOS Setup Control Group
329
IDE Control Chassis Index
Name
ideControlchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.60.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
IDE Control Index
Name
ideControlIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.60.1.2
Description
Defines the index (one-based) of the IDE controller in this chassis.
Syntax
DellObjectRange
Access
Read-only
IDE Control Capabilities Unique
Name
ideControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.60.1.3
Description
Defines the capabilities of the IDE controller.
Syntax
DellideControlCapabilitiesUnique (See Table 16-15.)
Access
Read-only
IDE Control Settings Unique
330
Name
ideControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.60.1.4
Description
Defines the settings for the IDE controller.
Syntax
DellideControlCapabilitiesUnique (See Table 16-15.)
Access
Read-only
BIOS Setup Control Group
IDE Control Status
Name
ideControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.60.1.5
Description
Defines the status for the IDE controller.
Syntax
DellStatus
Access
Read-only
IDE Control Name
Name
ideControlName
Object ID
1.3.6.1.4.1.674.10892.1.1400.60.1.6
Description
Defines the setup BIOS name for the IDE controller.
Syntax
DellStatus
Access
Read-only
Diskette Control Table
Name
disketteControlTable
Object ID
1.3.6.1.4.1.674.10892.1.1400.70
Description
Defines the Diskette Control Table.
Syntax
DisketteControlTableEntry
Access
Not accessible
Diskette Control Table Entry
Name
disketteControlTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1400.70.1
Description
Defines the Diskette Control Table entry.
Syntax
DellStatus
Access
Not accessible
Index
disketteControlchassisIndex, disketteControlIndex
BIOS Setup Control Group
331
Diskette Control Chassis Index
Name
disketteControlchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.70.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Diskette Control Index
Name
disketteControlIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.70.1.2
Description
Defines the index of the diskette controllers in this chassis.
Syntax
DellObjectRange
Access
Read-only
Diskette Control Capabilities Unique
Name
disketteControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.70.1.3
Description
Defines the capabilities of the diskette controller.
Syntax
DellDisketteControlCapabilitiesUnique (See Table 16-16.)
Access
Read-only
Diskette Control Settings Unique
332
Name
disketteControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.70.1.4
Description
Defines the control settings for the diskette controller.
Syntax
DellDisketteControlSettingsUnique
Access
Read-only
BIOS Setup Control Group
Diskette Control Status
Name
disketteControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.70.1.5
Description
Defines the status of the diskette controller.
Syntax
DellStatus
Access
Read-only
Diskette Control Name
Name
disketteControlName
Object ID
1.3.6.1.4.1.674.10892.1.1400.70.1.6
Description
Defines the setup BIOS name of the diskette controller.
Syntax
DellString
Access
Read-only
Network Interface Control Table
These MIB objects enable you to track the attributes of the NIC card for your system.
Name
networkInterfaceControlTable
Object ID
1.3.6.1.4.1.674.10892.1.1400.80
Description
Defines the Network Interface Control Table.
Syntax
NetworkInterfaceControlTableEntry
Access
Not accessible
Network Interface Control Table Entry
Name
networkInterfaceControlTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1400.80.1
Description
Defines the Network Interface Control Table entry.
Syntax
NetworkInterfaceControlTableEntry
Access
Not accessible
Index
networkInterfaceControlchassisIndex, networkInterfaceControlIndex
BIOS Setup Control Group
333
Network Interface Control Chassis Index
Name
networkInterfaceControlchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.80.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Network Interface Control Index
Name
networkInterfaceControlIndex
Object ID
1.3.6.1.4.1.674.10892.1.1400.80.1.2
Description
Defines the index (one-based) of the network interface controller in
this chassis.
Syntax
DellObjectRange
Access
Read-only
Network Interface Control Capabilities Unique
Name
networkInterfaceControlCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.80.1.3
Description
Defines the capabilities of the NIC.
Syntax
DellNetworkInterfaceControlCapabilitiesUnique (See Table 16-17.)
Access
Read-only
Network Interface Control Settings Unique
334
Name
networkInterfaceControlSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1400.80.1.4
Description
Defines the control settings for the NIC.
Syntax
DellNetworkInterfaceControlSettingsUnique (See Table 16-18.)
Access
Read-write
BIOS Setup Control Group
Network Interface Control Status
Name
networkInterfaceControlStatus
Object ID
1.3.6.1.4.1.674.10892.1.1400.80.1.5
Description
Defines the status of the NIC.
Syntax
DellStatus
Access
Read-only
Network Interface Control Name
Name
networkInterfaceControlName
Object ID
1.3.6.1.4.1.674.10892.1.1400.80.1.6
Description
Defines the setup BIOS name of the NIC.
Syntax
DellString
Access
Read-only
BIOS Group Variable Values
This section includes definitions for server administrator-specific variable values used in this section.
Table 16-1.
Speaker Control Capabilities Unique
Variable Name: DellSpeakerControlCapabilitiesUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
Speaker control capabilities are unknown.
enableCapable(2)
Setup BIOS can enable speaker control.
lowCapable(4)
Setup BIOS can set the speaker volume to low.
mediumCapable(8)
Setup BIOS can set the speaker volume
to medium.
highCapable(16)
Setup BIOS can set the speaker volume to high.
allVolumeCapable(30)
Setup BIOS can set the speaker volume to any of
the three settings.
BIOS Setup Control Group
335
Table 16-2.
Speaker Control Settings Unique
Variable Name: DellSpeakerControlSettingsUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
Speaker control state is unknown.
enabled(2)
Speaker control is enabled.
low(4)
Speaker control volume is low.
medium(8)
Speaker control volume is medium.
high(16)
Speaker control volume is high.
Table 16-3.
Network Interface (NIF) Wakeup on LAN Capabilities Unique
Variable Name: DellNIFwakeonLanControlCapabilitiesUnique
Data Type: Integer
336
Possible Data Values
Meaning of Data Value
unknown(1)
Setup BIOS Wakeup on LAN capabilities are
unknown.
enableCapable(2)
Setup BIOS is capable of enabling the NIF
Wakeup on LAN.
addInCardCapable(4)
Setup BIOS is capable of enabling Wakeup on
LAN by option card.
onBoardCapable(8)
Setup BIOS is capable of enabling Wakeup on
LAN by integrated NIF.
bothCapable(14)
Setup BIOS is capable of enabling Wakeup on
LAN by either option card or integrated NIF.
BIOS Setup Control Group
Table 16-4.
NIF Wakeup on LAN Control Settings Unique
Variable Name: DellNIFwakeonLanControlSettingsUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
NIF Wakeup on LAN state is unknown.
enabled(2)
NIF Wakeup on LAN is enabled.
addInCard(4)
NIF Wakeup on LAN is by option card.
onBoard(8)
NIF Wakeup on LAN is by integrated NIF.
addInCardOrOnBoard(12)
NIF Wakeup on LAN is by option card or
integrated NIF.
Table 16-5.
Boot Sequence Control Capabilities Unique
Variable Name: DellBootSequenceControlCapabilitiesUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
bootSequenceUnknown(1)
Boot sequence capabilities are unknown.
bootFromDisketteFirstCapable(2)
Setup BIOS can boot from a diskette first.
bootFromhardDriveFirstCapable(4)
Setup BIOS can boot from an IDE hard drive first.
bootFromDisketteORHardDriveFirst
Capable(6)
Setup BIOS can boot from a diskette or an
IDE hard drive first.
bootFromDeviceListCapable(8)
Setup BIOS can boot from a device list.
bootFromCDROMFirstCapable(16)
Setup BIOS can boot from a CD first.
allFirstCapable(30)
Setup BIOS can boot by any of the preceding
methods first.
BIOS Setup Control Group
337
Table 16-6.
Boot Sequence Control Settings Unique
Variable Name: DellBootSequenceControlSettingsUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
bootSequenceUnknown(1)
Boot sequence state is unknown.
bootFromDisketteFirst(2)
Setup BIOS is set to boot by diskette first.
bootFromHardDriveFirst(4)
Setup BIOS is set to boot by IDE hard drive
first.
bootFromDeviceList(8)
Setup BIOS is set to boot by a device list.
bootFromCDROMFirst(16)
Setup BIOS is set to boot by CD first.
Table 16-7.
BIOS Password Control Capabilities
Variable Name: DellBIOSPasswordControlCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
passwordControlCapabilitiesUnknown(1)
BIOS password capabilities are unknown.
passwordControlEnableCapable(2)
Setup BIOS is capable of enabling password
changes.
passwordControlJumperDisableCapable(4) Setup BIOS is capable of determining if
password control can be jumper disabled.
passwordControlEnableANDJumperDisable Setup BIOS is capable of enabling password
Capable(6)
changes and of determining if password
control can be jumper disabled.
Table 16-8.
BIOS Password Control Settings Unique
Variable Name: DellBIOSPasswordControlSettingsUnique
Data Type: Integer
338
Possible Data Values
Meaning of Data Value
passwordControlSettingsUnknown(1)
Setup BIOS password state is unknown.
passwordControlEnabled(2)
Setup BIOS has password changes enabled.
passwordControlJumperDisabled(4)
Setup BIOS has determined that password
control has been disabled by a jumper.
BIOS Setup Control Group
Table 16-9.
BIOS Password Control Settings
Variable Name: DellBIOSPasswordControlSettingsUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
passwordControlSettingsUnknown(1)
Setup BIOS password state is unknown.
passwordControlEnabled(2)
Setup BIOS has password changes enabled.
passwordControlJumperDisabled(4)
Setup BIOS has determined that password
control has been disabled by a jumper.
Table 16-10. Parallel Port Control Capabilities
Variable Name: DellParallelPortControlCapabilitiesUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
Setup BIOS parallel port capabilities
are unknown.
enableCapable(2)
Setup BIOS can enable the parallel port.
lpt1Capable(4)
Setup BIOS can support parallel port 1.
lpt1andEnableCapable(6)
Setup BIOS has enabled parallel port 1.
lpt2Capable(8)
Setup BIOS can support parallel port 2.
lpt2andEnableCapable(10)
Setup BIOS has enabled parallel port 2.
lpt3Capable(16)
Setup BIOS can support parallel port 3.
lpt3andEnableCapable(18)
Setup BIOS has enabled parallel port 3.
allParallelPortCapable(30)
Setup BIOS can support any of the three
parallel ports.
BIOS Setup Control Group
339
Table 16-11. Parallel Port Control Settings
Variable Name: DellParallelPortControlSettingsUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
Parallel port state is unknown.
enabled(2)
Setup BIOS has enabled the parallel port.
lpt1(4)
Setup BIOS supports parallel port 1.
lpt1Enabled(6)
Setup BIOS has enabled parallel port 1.
lpt2(8)
Setup BIOS supports parallel port 2.
lpt2Enabled(10)
Setup BIOS has enabled parallel port 2.
lpt3(16)
Setup BIOS supports parallel port 3.
Table 16-12. Parallel Port Control Mode Settings
Variable Name: DellParallelPortControlModeSettingsUnique
Data Type: Integer
340
Possible Data Values
Meaning of Data Value
unknown(1)
Parallel port mode is unknown.
atModeEnabled(2)
Setup BIOS has set the parallel port to AT mode.
ps2ModeEnabled(4)
Setup BIOS has set the parallel port to Personal
Systems/2 (PS/2) mode.
ecpModeEnabled(8)
Setup BIOS has set the parallel port to Extended
Capabilities Port (ECP) mode.
eppModeEnabled(16)
Setup BIOS has set the parallel port to Enhanced
Parallel Port (EPP) mode.
BIOS Setup Control Group
Table 16-13. Serial Port Control Capabilities
Variable Name: DellSerialPortControlCapabilitiesUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
Setup BIOS serial port capabilities are unknown.
enableCapable(2)
Setup BIOS can enable the serial port.
com1Capable(4)
Setup BIOS can support serial port 1.
enableAndCom1Capable(6)
Setup BIOS can enable serial port 1.
com2Capable(8)
Setup BIOS can support serial port 2.
enableAndCom2Capable(10)
Setup BIOS is capable of enabling serial port 2.
com3Capable(16)
Setup BIOS can support serial port 3.
enableAndCom3Capable(18)
Setup BIOS is capable of enabling serial port 3.
com4Capable(32)
Setup BIOS can support serial port 4.
enableAndCom4Capable(34)
Setup BIOS is capable of enabling serial port 4.
autoConfigCapable(64)
Setup BIOS is capable of autoconfiguring all
serial ports.
com1OrCom3CapableAndAutoConfigCap Setup BIOS has enabled autoconfiguration of
able(86)
COM1 and COM3 serial ports.
com2OrCom4CapableAndAutoConfigCap Setup BIOS has enabled autoconfiguration of
able(106)
COM2 and COM4 serial ports.
allcomCapable(126)
Setup BIOS is capable of enabling or
autoconfiguring all serial ports.
BIOS Setup Control Group
341
Table 16-14. Serial Port Control Settings
Variable Name: DellSerialPortControlSettingsUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
Serial port state is unknown.
enabled(2)
Setup BIOS has enabled the serial port.
com1(4)
Setup BIOS has selected serial port 1.
com1Enabled(6)
Setup BIOS has enabled serial port 1.
com2(8)
Setup BIOS has selected serial port 2.
com2Enabled(10)
Setup BIOS has enabled serial port 2.
com3(16)
Setup BIOS has selected serial port 3.
com3Enabled(18)
Setup BIOS has enabled serial port 3.
com4(32)
Setup BIOS has selected serial port 4.
com4Enabled(34)
Setup BIOS has enabled serial port 4.
comPortsAutoConfig(64)
Setup BIOS has selected autoconfiguration of serial ports.
enabledAndAutoConfig(66)
Setup BIOS has enabled autoconfiguration of serial ports.
Table 16-15. IDE Control Capabilities
Variable Name: DellideControlCapabilitiesUnique
Data Type: Integer
342
Possible Data Values
Meaning of Data Value
unknown(1)
IDE control capabilities are unknown.
ideControlAutoConfigOrEnableCapable(2)
IDE controller is autoconfigurable or enable capable.
BIOS Setup Control Group
Table 16-16. Diskette Control Settings
Variable Name: DellDisketteControlSettingsUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
Diskette control state is unknown.
disketteControlAutoConfigEnabledOrEnabled(2) Diskette control is set as autoconfigurable
or enabled.
Table 16-17. Network Interface Control Capabilities
Variable Name: DellNetworkInterfaceControlCapabilitiesUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
Unknown setup BIOS network interface capabilities.
enableCapable(2)
Setup BIOS is capable of enabling the network interface.
enableWithoutPXECapable(4)
Setup BIOS is capable of enabling the NIF without Preboot eXecution Environment (PXE).
Table 16-18. Network Interface Control Settings
Variable Name: DellNetworkInterfaceControlSettingsUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
Network interface state is unknown.
enabled(2)
Network interface is enabled.
enabledWithoutPXE(4)
Network interface is enabled without PXE.
BIOS Setup Control Group
343
344
BIOS Setup Control Group
Local Response Agent Group
The Local Response Agent Group provides information about various attributes of your system’s
local response agent (LRA). The LRA allows systems managers to predetermine how a system
running the server administrator will respond to a particular event type, such as the loss of
redundancy in a specific component or the elevation of temperature in a chassis. Systems managers
can configure the LRA to respond to an event type with a specific action. When the condition of the
critical component worsens, the systems manager can escalate the response to make it more obvious
to the operator.
For example, when a voltage probe on a monitored machine reaches a warning condition, the
systems manager may want to notify the operator by causing the machine to beep. When the
voltage probe reaches failure, the systems manager might want to have the system that has a failing
component send a broadcast message to the management system and power off the troubled system.
LRA Group Tables
The following management information base (MIB) tables define LRA variable attributes:
•
LRA Global Settings Table
•
LRA Action Table
LRA Global Settings
The global settings table allows the systems manager to determine what LRA capabilities exist for a
specific system that is running Server Administrator. Some machines may support all or some of the
capabilities described in DellLocalResponseAgentCapabilitiesUnique. The LRA Global Settings Table
also defines thermal shutdown capabilities and settings. In the event that a temperature probe
determines the temperature is at or over the failure limit, the systems manager can set an action
to be taken automatically.
LRA Global Settings Table
Name
lRAGlobalSettingsTable
Object ID
1.3.6.1.4.1.674.10892.1.1500.10
Description
Defines the LRA Global Settings Table.
Syntax
SEQUENCE OF LRAGlobalSettingsTableEntry
Access
Not accessible
Local Response Agent Group
345
LRA Global Settings Table Entry
Name
lRAGlobalSettingsTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1500.10.1
Description
Defines the LRA Global Settings Table entry.
Syntax
LRAGlobalSettingsTableEntry
Access
Not accessible
Index
lRAGlobalchassisIndex
LRA Global Chassis Index
Name
lRAGlobalchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1500.10.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
LRA Global State
346
Name
lRAGlobalState
Object ID
1.3.6.1.4.1.674.10892.1.1500.10.1.2
Description
Defines the state of the LRA global settings.
Syntax
DellStateSettings
Access
Read-only
Local Response Agent Group
LRA Global Settings Disable Time-out Value
Name
lRAGlobalSettingsDisableTimeoutValue
Object ID
1.3.6.1.4.1.674.10892.1.1500.10.1.3
Description
Defines the time-out duration countdown, in seconds, that the
LRA global settings will be disabled after a system shutdown and reboot.
Syntax
DellUnsigned32BitRange
Access
Read-only
LRA Global Settings Capabilities Unique
Name
lRAGlobalSettingsCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1500.10.1.4
Description
Defines the set of global capabilities that all local response agents
may or may not allow to be set or reset.
Syntax
DellLocalResponseAgentCapabilitiesUnique (See Table 17-1.)
Access
Read-only
LRA Global Thermal Shutdown Capabilities Unique
Name
lRAGlobalThermalShutdownCapabilitiesUnique
Object ID
1.3.6.1.4.1.674.10892.1.1500.10.1.5
Description
Defines the set of thermal shutdown capabilities that are supported by
the LRA.
Syntax
DellLRAThermalShutdownCapabilitiesUnique
Access
Read-only
LRA Global Thermal Shutdown State Settings Unique
Name
lRAGlobalThermalShutdownStateSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1500.10.1.6
Description
Defines the set of thermal shutdown state and settings that the local
response agent supports.
Syntax
DellLRAThermalShutdownStateSettingsUnique
Access
Read-write
Local Response Agent Group
347
LRA Action Table
The DellLocalResponseAgentCapabilitiesUnique variable in the global action table defines
the capabilities that are allowed for a particular system. The LRA Action Table that follows selects which
of the system’s capabilities (global actions) are to be enabled.
Name
lRAActionTableTable
Object ID
1.3.6.1.4.1.674.10892.1.1500.20
Description
Defines the LRA Action Table.
Syntax
SEQUENCE OF LRAActionTableTableEntry
Access
Not accessible
LRA Action Table Entry
Name
lRAActionTableTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1500.20.1
Description
Defines the LRA Action Table entry.
Syntax
LRAActionTableTableEntry
Access
Not accessible
Index
lRAActionTablechassisIndex, lRAActionTableActionNumberIndex
LRA Action Table Chassis Index
348
Name
lRAActionTablechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1500.20.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Local Response Agent Group
LRA Action Table Action Number Index
Name
lRAActionTableActionNumberIndex
Object ID
1.3.6.1.4.1.674.10892.1.1500.20.1.2
Description
Defines the LRA action number index. The action number indexes are
as follows:
160 — temperature failure action definition
168 — cooling device failure action definition
172 — voltage failure action definition
200 — temperature warning action definition
202 — voltage warning action definition
204 — cooling device warning action definition
206 — amperage failure action definition
208 — amperage warning action definition
210 — a power or cooling unit redundancy lost action definition
212 — a power or cooling unit redundancy degraded action definition
214 — power supply failed action definition
220 — chassis intrusion action definition
228 — memory device warning action definition
474 — memory device failure action definition
1006 — automatic system recovery (ASR) action definition
1353 — power supply warning action definition
1553 — log near full action definition
1554 — log full action definition
1603 — processor warning action definition
1604 — processor failure action definition
1703 — battery warning action definition
1704 — battery failure action definition
Syntax
DellUnsigned16BitRange
Access
Read-only
Local Response Agent Group
349
LRA Action Table User Application Name
Name
lRAActionTableUserApplicationName
Object ID
1.3.6.1.4.1.674.10892.1.1500.20.1.3
Description
When the "execute application value" is set, provides the following
user-assignable LRA information:
• Name of the user application executable path
• File name to execute
Syntax
DisplayString (SIZE (0..256))
Access
Read-write
LRA Action Table Settings Unique
Name
lRAActionTableSettingsUnique
Object ID
1.3.6.1.4.1.674.10892.1.1500.20.1.4
Description
Defines the LRA settings.
Syntax
DellLocalResponseAgentSettingsUnique (See Table 17-3.)
Access
Read-write
Local Response Agent Variable Values
This section includes definitions for server administrator-specific variable values used in this section.
Table 17-1.
LRA Capabilities Definitions
Variable Name: DellLocalResponseAgentCapabilitiesUnique
Data Type: Integer
350
Possible Data Values
Meaning of Data Value
speakerControlCapable(1)
The LRA can issue a speaker beep.
consoleAlertCapable(2)
The LRA can alert the console.
broadcastMessageCapable(4)
The LRA can broadcast a message.
osShutDownCapable(8)
The LRA can shut down the operating system.
rebootCapable(16)
The LRA can reboot the system.
powerCycleCapable(32)
The LRA is capable of a system power cycle.
powerOFFCapable(64)
The LRA can shut the system power off.
executeApplicationCapable(256)
The LRA can execute a user mode application.
lraFullyCapable(383)
The LRA has all of the preceding capabilities.
Local Response Agent Group
Table 17-2.
LRA Thermal Shutdown Capabilities Unique
Variable Name: DellLRAThermalShutdownCapabilitiesUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The LRA has no thermal shutdown capabilities.
Unknown capabilities(1)
The LRA’s thermal shutdown capabilities are unknown.
enableCapable(2)
The LRA can be disabled (offline, a binary 0 value) or enabled
(online, a binary 1 value).
warningCapable(4)
The LRA can carry out chassis-determined action(s) when a
warning condition is detected.
enableOnWarningCapable(6)
The LRA enables activation of chassis-determined action(s)
when a warning condition is detected.
failureCapable(8)
The LRA can carry out chassis-determined action(s) when a
failure condition is detected.
enableOnFailureCapable(10)
The LRA enables activation of chassis-determined action(s)
when a failure condition is detected.
enableOnWarningOrFailureCapable(14) The LRA enables activation of chassis-determined action(s)
when either a failure or a warning condition is detected.
Table 17-3.
Local Response Agent Settings Unique
Variable Name: DellLocalResponseAgentSettingsUnique
Data Type: Integer
Possible Data Values
Meaning of Data Value
speakerControl(1)
LRA is set to issue a speaker beep.
consoleAlert(2)
LRA is set to issue a console alert.
broadcastMessage(4)
LRA is set to issue a broadcast message.
osShutDown(8)
LRA is set to issue an operating system shutdown.
reboot(16)
LRA is set to issue a system reboot.
powerCycle(32)
LRA is set to issue a system power cycle.
powerOFF(64)
LRA is set to issue a system power off.
executeApplication(256)
LRA is set to start a user mode application.
allLRASettingsUnique(383)
LRA is set to all LRA settings combinations.
Local Response Agent Group
351
352
Local Response Agent Group
Cost of Ownership Group
The Cost of Ownership (COO) Group provides a full set of cost-tracking objects, including fields for
the computer’s manufacturer, insurer, lessor, warranty, user, trouble tickets, and many others. You can
use these management information base (MIB) objects to obtain accurate and complete
measurements of the cost of each computer asset in your organization.
Cost of Ownership Group Tables
The Cost of Ownership Group defines objects in the following MIB tables:
•
Cost of Ownership Table
•
COO Service Contract Table
•
COO Cost Event Log Table
•
COO Warranty Table
•
COO Lease Information Table
•
COO Schedule Number Table
•
COO Options Table
•
COO Maintenance Table
•
COO Repair Table
•
COO Support Information Table
•
COO Trouble Ticket Table
Cost of Ownership Table
The following MIB object sets up the Cost of Ownership Table.
Name
cooTable
Object ID
1.3.6.1.4.1.674.10892.1.1600.10
Description
Defines the Cost of Ownership Table.
Syntax
SEQUENCE OF CooTableEntry
Access
Not accessible
Cost of Ownership Group
353
Cost of Ownership Table Entry
Name
cooTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1
Description
Defines the Cost of Ownership Table entry.
Syntax
CooTableEntry
Access
Not accessible
Index
coochassisIndex
COO Chassis Index
Name
coochassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
CooTableEntry
Access
Read-only
COO State
Name
cooState
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.2
Description
Defines the acquisition state of the system.
Syntax
DellStateSettings
Access
Read-only
COO Acquisition Purchase Cost
354
Name
cooAquisitionPurchaseCost
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.3
Description
Defines the purchase cost of the system.
Syntax
DellUnsigned32BitRange
Access
Read-write
Cost of Ownership Group
COO Acquisition Waybill Number
Name
cooAquisitionWayBillNumber
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.4
Description
Defines the waybill number of the system.
Syntax
DellUnsigned32BitRange
Access
Read-write
COO Acquisition Install Date Name
Name
cooAquisitionInstallDateName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.5
Description
Defines the installation date and time for the system.
Syntax
DellDateName
Access
Read-write
COO Acquisition Purchase Order
Name
cooAquisitionPurchaseOrder
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.6
Description
Defines the purchase order number of the system.
Syntax
DellUnsigned32BitRange
Access
Read-write
COO Acquisition Purchase Date Name
Name
cooAquisitionPurchaseDateName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.7
Description
Defines the purchase date and time of the system.
Syntax
DellDateName
Access
Read-write
Cost of Ownership Group
355
COO Acquisition Signing Authority Name
Name
cooAquisitionSigningAuthorityName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.8
Description
Defines the name of the authorized person who signs for the system.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Original Machine Configuration Expensed
Name
cooOriginalMachineConfigurationExpensed
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.9
Description
Specifies whether the purchase of this system was expensed.
Syntax
DellBoolean
Access
Read-write
COO Original Machine Configuration Vendor Name
Name
cooOriginalMachineConfigurationVendorName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.10
Description
Defines the vendor name of the system.
Syntax
DellCostofOwnershipString
Access
Read-only
COO Cost Center Information Vendor Name
356
Name
cooCostCenterInformationVendorName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.11
Description
Defines the cost center name of the system.
Syntax
DellCostofOwnershipString
Access
Read-write
Cost of Ownership Group
COO User Information User Name
Name
cooUserInformationUserName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.12
Description
Defines the name of the user for this system.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Extended Warranty Start Date Name
Name
cooExtendedWarrantyStartDateName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.13
Description
Defines the extended warranty start date for this system.
Syntax
DellDateName
Access
Read-write
COO Extended Warranty End Date Name
Name
cooExtendedWarrantyEndDateName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.14
Description
Defines the extended warranty end date for this system.
Syntax
DellDateName
Access
Read-write
COO Extended Warranty Cost
Name
cooExtendedWarrantyCost
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.15
Description
Defines the extended warranty cost date for this system.
Syntax
DellUnsigned32BitRange
Access
Read-write
Cost of Ownership Group
357
COO Extended Warranty Provider Name
Name
cooExtendedWarrantyProviderName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.16
Description
Defines the name of the extended warranty provider for this system.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Ownership Code
Name
cooOwnershipCode
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.17
Description
Defines the ownership code for this system.
Syntax
DellCooOwnershipCodes (See Table 18-1.)
Access
Read-write
COO Corporate Owner Name
Name
cooCorporateOwnerName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.18
Description
Defines the name of the corporation that owns this system.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Hazardous Waste Code Name
358
Name
cooHazardousWasteCodeName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.19
Description
Defines the hazardous waste code for this system.
Syntax
DellCostofOwnershipString
Access
Read-write
Cost of Ownership Group
COO Deployment Date Length
Name
cooDeploymentDateLength
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.20
Description
Defines the deployment time for this system.
Syntax
DellUnsigned32BitRange
Access
Read-write
COO Deployment Duration Type
Name
cooDeploymentDurationType
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.21
Description
Defines the deployment time units for this system.
Syntax
DellCooHourDayDurationType (See Table 18-2.)
Access
Read-write
COO Training Name
Name
cooTrainingName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.22
Description
Defines the training that the user has for this system.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Outsourcing Problem Description Name
Name
cooOutsourcingProblemDescriptionName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.23
Description
Defines a problem encountered with the outsourcing service provider.
Syntax
DellCostofOwnershipString
Access
Read-write
Cost of Ownership Group
359
COO Outsourcing Service Fee Name
Name
cooOutsourcingServiceFeeName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.24
Description
Defines amount that the outsourcing vendor charges for service.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Outsourcing Signing Authority Name
Name
cooOutsourcingSigningAuthorityName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.25
Description
Defines the name of the person who can sign the authorization for service.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Outsourcing Provider Fee Name
Name
cooOutsourcingProviderFeeName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.26
Description
Defines any additional outsourcing charge for service.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Outsourcing Provider Service Level Name
360
Name
cooOutsourcingProviderServiceLevelName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.27
Description
Defines the service level agreement for the system.
Syntax
DellCostofOwnershipString
Access
Read-write
Cost of Ownership Group
COO Insurance Company Name
Name
cooInsuranceCompanyName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.28
Description
Defines the name of the company that insures this system.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Box Asset Tag Name
Name
cooBoxAssetTagName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.29
Description
Defines the name of the asset tag.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Box System Name
Name
cooBoxSystemName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.30
Description
Defines the name of the system.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Box Central Processing Unit (CPU) Serial Number Name
Name
cooBoxCPUSerialNumberName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.31
Description
Defines the name of the CPU serial number for the system.
Syntax
DellCostofOwnershipString
Access
Read-write
Cost of Ownership Group
361
COO Operating System Upgrade Type Name
Name
cooOperatingSystemUpgradeTypeName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.32
Description
Defines the name of the operating system on this system.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Operating System Upgrade Patch Level Name
Name
cooOperatingSystemUpgradePatchLevelName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.33
Description
Defines the name of the operating system patch level for this system.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Operating System Upgrade Date
Name
cooOperatingSystemUpgradeDate
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.34
Description
Defines the upgrade file date for this operating system.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Depreciation Duration
362
Name
cooDepreciationDuration
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.35
Description
Defines the length of depreciation for this system.
Syntax
DellUnsigned32BitRange
Access
Read-write
Cost of Ownership Group
COO Depreciation Duration Type
Name
cooDepreciationDurationType
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.36
Description
Defines the unit of time for the depreciation of this system.
Syntax
DellCooMonthYearDurationType
Access
Read-write
COO Depreciation Percentage
Name
cooDepreciationPercentage
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.37
Description
Defines the percentage of depreciation for this system.
Syntax
DellUnsigned32BitRange
Access
Read-write
COO Depreciation Method Name
Name
cooDepreciationMethodName
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.38
Description
Defines the name of the depreciation method for this system.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Registration Is Registered
Name
cooRegistrationIsRegistered
Object ID
1.3.6.1.4.1.674.10892.1.1600.10.1.39
Description
Specifies whether this system is registered or not.
Syntax
DellBoolean
Access
Read-write
Cost of Ownership Group
363
COO Service Contract Table
The service contract table provides MIB objects that help you track the name, vendor, and type of service
contract you have for your system.
Name
cooServiceContractTable
Object ID
1.3.6.1.4.1.674.10892.1.1600.20
Description
Defines the COO Service Contract Table.
Syntax
SEQUENCE OF CooServiceContractTableEntry
Access
Not accessible
COO Service Contract Table Entry
Name
cooServiceContractTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1600.20.1
Description
Defines the COO Service Contract Table entry.
Syntax
CooServiceContractTableEntry
Access
Not accessible
Index
cooServiceContractchassisIndex, cooServiceContractIndex
COO Service Contract Chassis Index
Name
cooServiceContractchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.20.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
COO Service Contract Index
364
Name
cooServiceContractIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.20.1.2
Description
Defines the index (one-based) of this service contract.
Syntax
DellObjectRange
Access
Read-only
Cost of Ownership Group
COO Service Contract State
Name
cooServiceContractState
Object ID
1.3.6.1.4.1.674.10892.1.1600.20.1.3
Description
Defines the status of the service contract for this system.
Syntax
DellStateSettings
Access
Read-only
COO Service Contract Was Renewed
Name
cooServiceContractWasRenewed
Object ID
1.3.6.1.4.1.674.10892.1.1600.20.1.4
Description
Specifies whether the service contract for this system was renewed.
Syntax
DellBoolean
Access
Read-write
COO Service Contract Type Name
Name
cooServiceContractTypeName
Object ID
1.3.6.1.4.1.674.10892.1.1600.20.1.5
Description
Defines the name of the service contract type for this system.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Service Contract Vendor Name
Name
cooServiceContractVendorName
Object ID
1.3.6.1.4.1.674.10892.1.1600.20.1.6
Description
Defines the name of the service contract provider for this system.
Syntax
DellCostofOwnershipString
Access
Read-write
Cost of Ownership Group
365
COO Cost Event Log Table
The COO Cost Event Log Table provides MIB objects that allow you to track the duration and type of
events that are logged for a particular system.
Name
cooCostEventLogTable
Object ID
1.3.6.1.4.1.674.10892.1.1600.30
Description
Defines the COO Cost Event Log Table.
Syntax
SEQUENCE OF COO CostEventLogTableEntry
Access
Not accessible
COO Cost Event Log Table Entry
Name
cooCostEventLogTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1600.30.1
Description
Defines the COO Cost Event Log Table entry.
Syntax
cooCostEventLogTableEntry
Access
Not accessible
Index
cooCostEventLogchassisIndex, cooCostEventLogIndex
COO Cost Event Log Chassis Index
Name
cooCostEventLogchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.30.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
COO Cost Event Log Index
366
Name
cooCostEventLogIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.30.1.2
Description
Defines the index (one-based) of the cost event log.
Syntax
DellObjectRange
Access
Read-only
Cost of Ownership Group
COO Cost Event Log State
Name
cooCostEventLogState
Object ID
1.3.6.1.4.1.674.10892.1.1600.30.1.3
Description
Defines the cost event log state of this system.
Syntax
DellStateSettings
Access
Read-only
COO Cost Event Log Duration
Name
cooCostEventLogDuration
Object ID
1.3.6.1.4.1.674.10892.1.1600.30.1.4
Description
Defines the duration of the event for this system.
Syntax
DellUnsigned32BitRange
Access
Read-write
COO Cost Event Log Duration Type
Name
cooCostEventLogDurationType
Object ID
1.3.6.1.4.1.674.10892.1.1600.30.1.5
Description
Defines the duration type of the event for this system.
Syntax
DellCOOHourDayDurationType (See Table 18-2.)
Access
Read-write
COO Cost Event Log Description Name
Name
cooCostEventLogDescriptionName
Object ID
1.3.6.1.4.1.674.10892.1.1600.30.1.6
Description
Defines the name of the event description.
Syntax
DellCostofOwnershipString
Access
Read-write
Cost of Ownership Group
367
COO Warranty Table
The COO Warranty Table objects enable you to track facts about the type and duration of the warranty
for a particular system.
Name
cooWarrantyTable
Object ID
1.3.6.1.4.1.674.10892.1.1600.40
Description
Defines the COO Warranty Table.
Syntax
SEQUENCE OF CooWarrantyTableEntry
Access
Not accessible
COO Warranty Table Entry
Name
cooWarrantyTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1600.40.1
Description
Defines the COO Warranty Table entry.
Syntax
CooWarrantyTableEntry
Access
Not accessible
Index
cooWarrantychassisIndex, cooWarrantyIndex
COO Warranty Chassis Index
Name
cooWarrantychassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.40.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-write
COO Warranty Index
368
Name
cooWarrantyIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.40.1.2
Description
Defines the index of the warranty for this system.
Syntax
DellObjectRange
Access
Read-only
Cost of Ownership Group
COO Warranty State
Name
cooWarrantyState
Object ID
1.3.6.1.4.1.674.10892.1.1600.40.1.3
Description
Defines the state of the warranty for this system.
Syntax
DellStateSettings
Access
Read-only
COO Warranty Duration
Name
cooWarrantyDuration
Object ID
1.3.6.1.4.1.674.10892.1.1600.40.1.4
Description
Defines the duration of the warranty.
Syntax
DellUnsigned32BitRange
Access
Read-write
COO Warranty Duration Type
Name
cooWarrantyDurationType
Object ID
1.3.6.1.4.1.674.10892.1.1600.40.1.5
Description
Defines the warranty duration type for the system.
Syntax
DellCOODayMonthDurationType
Access
Read-write
COO Warranty End Date Name
Name
cooWarrantyEndDateName
Object ID
1.3.6.1.4.1.674.10892.1.1600.40.1.6
Description
Defines the warranty end date for this system.
Syntax
DellDateName
Access
Read-write
Cost of Ownership Group
369
COO Warranty Cost
Name
cooWarrantyCost
Object ID
1.3.6.1.4.1.674.10892.1.1600.40.1.7
Description
Defines the cost of the warranty for this system.
Syntax
DellUnsigned32BitRange
Access
Read-write
COO Lease Information Table
The COO lease information MIB objects enable you to track information about your lessor,
lease duration, and lease type for each system.
Name
cooLeaseInformationTable
Object ID
1.3.6.1.4.1.674.10892.1.1600.50
Description
Defines the COO Lease Information Table.
Syntax
SEQUENCE OF CooLeaseInformationTableEntry
Access
Not accessible
COO Lease Information Table Entry
Name
cooLeaseInformationTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1600.50.1
Description
Defines the COO Lease Information Table entry.
Syntax
CooLeaseInformationTableEntry
Access
Not accessible
Index
cooLeaseInformationchassisIndex, cooLeaseInformationIndex
COO Lease Information Chassis Index
370
Name
cooLeaseInformationchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.50.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Cost of Ownership Group
COO Lease Information Index
Name
cooLeaseInformationIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.50.1.2
Description
Defines the index of the lease information for this system.
Syntax
DellObjectRange
Access
Read-only
COO Lease Information State
Name
cooLeaseInformationState
Object ID
1.3.6.1.4.1.674.10892.1.1600.50.1.3
Description
Defines the lease information state for this system.
Syntax
DellStateSettings
Access
Read-write
COO Lease Information Multiple Schedules
Name
cooLeaseInformationMultipleSchedules
Object ID
1.3.6.1.4.1.674.10892.1.1600.50.1.4
Description
Defines whether there are multiple schedules for this lease.
Syntax
DellBoolean
Access
Read-only
COO Lease Information Buyout Amount
Name
cooLeaseInformationBuyOutAmount
Object ID
1.3.6.1.4.1.674.10892.1.1600.50.1.5
Description
Defines the balance purchase price for this system.
Syntax
DellUnsigned32BitRange
Access
Read-write
Cost of Ownership Group
371
COO Lease Information Lease Rate Factor
Name
cooLeaseInformationLeaseRateFactor
Object ID
1.3.6.1.4.1.674.10892.1.1600.50.1.6
Description
Defines the rate factor for the lease on this system.
Syntax
DellUnsigned32BitRange
Access
Read-write
COO Lease Information End Date Name
Name
cooLeaseInformationEndDateName
Object ID
1.3.6.1.4.1.674.10892.1.1600.50.1.7
Description
Defines the end date for the lease on this system.
Syntax
DellDateName
Access
Read-write
COO Lease Information Fair Market Value
Name
cooLeaseInformationFairMarketValue
Object ID
1.3.6.1.4.1.674.10892.1.1600.50.1.8
Description
Defines the fair market value of this system.
Syntax
DellUnsigned32BitRange
Access
Read-write
COO Lease Information Lessor Name
372
Name
cooLeaseInformationLessorName
Object ID
1.3.6.1.4.1.674.10892.1.1600.50.1.9
Description
Defines the name of the lessor of this system.
Syntax
DellCostofOwnershipString
Access
Read-write
Cost of Ownership Group
COO Schedule Number Table
Name
cooScheduleNumberTable
Object ID
1.3.6.1.4.1.674.10892.1.1600.60
Description
Defines the COO Schedule Number Information Table.
Syntax
SEQUENCE OF CooScheduleNumberTableEntry
Access
Not accessible
COO Schedule Number Table Entry
Name
cooScheduleNumberTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1600.60.1
Description
Defines the COO Schedule Number Information Table entry.
Syntax
CooScheduleNumberTableEntry
Access
Not accessible
Index
cooScheduleNumberchassisIndex, cooScheduleNumberIndex
COO Schedule Number Chassis Index
Name
cooScheduleNumberchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.60.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
COO Schedule Number Index
Name
cooScheduleNumberIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.60.1.2
Description
Defines the index of the schedule number information.
Syntax
DellObjectRange
Access
Read-only
Cost of Ownership Group
373
COO Schedule Number State
Name
cooScheduleNumberState
Object ID
1.3.6.1.4.1.674.10892.1.1600.60.1.3
Description
Defines the schedule number information state of this system.
Syntax
DellStateSettings
Access
Read-only
COO Schedule Number Lease Information Index Reference
Name
cooScheduleNumberLeaseInformationIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1600.60.1.4
Description
Defines the lease information index number to reference the
schedule number.
Syntax
DellUnsigned32BitRange
Access
Read-write
COO Schedule Number Description Name
Name
cooScheduleNumberDescriptionName
Object ID
1.3.6.1.4.1.674.10892.1.1600.60.1.5
Description
Describes the schedule number information.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Options Table
374
Name
cooOptionsTable
Object ID
1.3.6.1.4.1.674.10892.1.1600.70
Description
Defines the COO Options Table.
Syntax
SEQUENCE OF CooOptionsTableEntry
Access
Not accessible
Cost of Ownership Group
COO Options Table Entry
Name
cooOptionsTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1600.70.1
Description
Defines the COO Options Table entry.
Syntax
CooOptionsTableEntry
Access
Not accessible
Index
cooOptionschassisIndex
COO Options Chassis Index
Name
cooOptionschassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.70.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
COO Options Index
Name
cooOptionsIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.70.1.2
Description
Defines the index (one-based) of the option information for this
system.
Syntax
DellObjectRange
Access
Read-only
COO Options State
Name
cooOptionsState
Object ID
1.3.6.1.4.1.674.10892.1.1600.70.1.3
Description
Defines the option information state for this system.
Syntax
DellStateSettings
Access
Read-only
Cost of Ownership Group
375
COO Options Lease Information Index Reference
Name
cooOptionsLeaseInformationIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1600.70.1.4
Description
Defines the lease information index of the option information for
this system.
Syntax
DellUnsigned32BitRange
Access
Read-write
COO Options Description Name
Name
cooOptionsDescriptionName
Object ID
1.3.6.1.4.1.674.10892.1.1600.70.1.5
Description
Defines the option information description name.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Maintenance Table
Name
cooMaintenanceTable
Object ID
1.3.6.1.4.1.674.10892.1.1600.80
Description
Defines the COO Maintenance Table.
Syntax
SEQUENCE OF CooMaintenanceTableEntry
Access
Not accessible
COO Maintenance Table Entry
376
Name
cooMaintenanceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1600.80.1
Description
Defines the COO Maintenance Table entry.
Syntax
CooMaintenanceTableEntry
Access
Not accessible
Index
CooMaintenancechassisIndex, CooMaintenanceIndex
Cost of Ownership Group
COO Maintenance Chassis Index
Name
cooMaintenancechassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.80.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
COO Maintenance Index
Name
cooMaintenanceIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.80.1.2
Description
Defines the index of this system’s maintenance information.
Syntax
DellObjectRange
Access
Read-only
COO Maintenance State
Name
cooMaintenanceState
Object ID
1.3.6.1.4.1.674.10892.1.1600.80.1.3
Description
Defines the state of this system’s maintenance information.
Syntax
DellStateSettings
Access
Read-only
COO Maintenance Start Date Name
Name
cooMaintenanceStartDateName
Object ID
1.3.6.1.4.1.674.10892.1.1600.80.1.4
Description
Defines the start date for maintenance on this system.
Syntax
DellDateName
Access
Read-write
Cost of Ownership Group
377
COO Maintenance End Date Name
Name
cooMaintenanceEndDateName
Object ID
1.3.6.1.4.1.674.10892.1.1600.80.1.5
Description
Defines the end date for maintenance on this system.
Syntax
DellDateName
Access
Read-write
COO Maintenance Provider Name
Name
cooMaintenanceProviderName
Object ID
1.3.6.1.4.1.674.10892.1.1600.80.1.6
Description
Defines the maintenance provider’s name.
Syntax
DellStateSettings
Access
Read-write
COO Maintenance Restrictions Name
Name
cooMaintenanceRestrictionsName
Object ID
1.3.6.1.4.1.674.10892.1.1600.80.1.7
Description
Defines the maintenance agreement restrictions.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Repair Table
378
Name
cooRepairTable
Object ID
1.3.6.1.4.1.674.10892.1.1600.90
Description
Defines the COO Repair Table.
Syntax
SEQUENCE OF CooRepairTableEntry
Access
Not accessible
Cost of Ownership Group
COO Repair Table Entry
Name
cooRepairTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1600.90.1
Description
Defines the COO Repair Table entry.
Syntax
CooRepairTableEntry
Access
Not accessible
Index
cooRepairchassisIndex, cooRepairIndex
COO Repair Chassis Index
Name
cooRepairchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.90.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
COO Repair Index
Name
cooRepairIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.90.1.2
Description
Defines the index (one-based) of the repair information for this
system.
Syntax
DellObjectRange
Access
Read-only
COO Repair State
Name
cooRepairState
Object ID
1.3.6.1.4.1.674.10892.1.1600.90.1.3
Description
Defines the state of the repair information for this system.
Syntax
DellStateSettings
Access
Read-only
Cost of Ownership Group
379
COO Repair Counter
Name
cooRepairCounter
Object ID
1.3.6.1.4.1.674.10892.1.1600.90.1.4
Description
Defines the number of repairs that this system has undergone.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Repair Vendor Name
Name
cooRepairVendorName
Object ID
1.3.6.1.4.1.674.10892.1.1600.90.1.5
Description
Defines the name of the vendor that repairs this system.
Syntax
DellStateSettings
Access
Read-only
COO Support Information Table
Name
cooSupportInformationTable
Object ID
1.3.6.1.4.1.674.10892.1.1600.100
Description
Defines the COO Support Information Table.
Syntax
SEQUENCE OF cooSupportInformationTableEntry
Access
Not accessible
COO Support Information Table Entry
380
Name
cooSupportInformationTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1600.100.1
Description
Defines the COO Support Information Table entry.
Syntax
cooSupportInformationTableEntry
Access
Not accessible
Index
cooSupportInformationchassisIndex cooSupportInformationIndex
Cost of Ownership Group
COO Support Information Chassis Index
Name
cooSupportInformationchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.100.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
COO Support Information Index
Name
cooSupportInformationIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.100.1.2
Description
Defines the index (one-based) for this system’s support information.
Syntax
DellObjectRange
Access
Read-only
COO Support Information State
Name
cooSupportInformationState
Object ID
1.3.6.1.4.1.674.10892.1.1600.100.1.3
Description
Defines the support information state for this system.
Syntax
DellStateSettings
Access
Read-only
COO Support Information Is Outsourced
Name
cooSupportInformationIsOutsourced
Object ID
1.3.6.1.4.1.674.10892.1.1600.100.1.4
Description
Specifies whether the support for this system is outsourced or not.
Syntax
DellBoolean
Access
Read-write
Cost of Ownership Group
381
COO Support Information Type
Name
cooSupportInformationType
Object ID
1.3.6.1.4.1.674.10892.1.1600.100.1.5
Description
Defines the type of component, system, or network problem that
occurred.
Syntax
DellUnsigned32BitRange
Access
Read-write
COO Support Information Help Desk Name
Name
cooSupportInformationHelpDeskName
Object ID
1.3.6.1.4.1.674.10892.1.1600.100.1.6
Description
Defines the help desk information provided.
Syntax
DellCostofOwnershipString
Access
Read-write
COO Support Information Fix Type Name
382
Name
cooSupportInformationFixTypeName
Object ID
1.3.6.1.4.1.674.10892.1.1600.100.1.7
Description
Defines the method used to fix the problem.
Syntax
DellCostofOwnershipString
Access
Read-write
Cost of Ownership Group
COO Trouble Ticket Table
The MIB objects in the Trouble Ticket Table enable you to track details of any trouble tickets that you
open for your system.
Name
cooTroubleTicketTable
Object ID
1.3.6.1.4.1.674.10892.1.1600.110
Description
Defines the COO Trouble Ticket Table.
Syntax
SEQUENCE OF cooTroubleTicketTableEntry
Access
Not accessible
COO Trouble Ticket Table Entry
Name
cooTroubleTicketTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1600.110.1
Description
Defines the COO Trouble Ticket Table entry.
Syntax
cooTroubleTicketTableEntry
Access
Not accessible
Index
cooTroubleTicketchassisIndex, cooTroubleTicketIndex
COO Trouble Ticket Chassis Index
Name
cooTroubleTicketchassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.110.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
COO Trouble Ticket Index
Name
cooTroubleTicketIndex
Object ID
1.3.6.1.4.1.674.10892.1.1600.110.1.2
Description
Defines the index (one-based) of the system’s trouble ticket
information.
Syntax
DellObjectRange
Access
Read-only
Cost of Ownership Group
383
COO Trouble Ticket State
Name
cooTroubleTicketState
Object ID
1.3.6.1.4.1.674.10892.1.1600.110.1.3
Description
Defines the trouble ticket information state for this system.
Syntax
DellStateSettings
Access
Read-only
COO Trouble Ticket Support Information Index Reference
Name
cooTroubleTicketSupportInformationIndexReference
Object ID
1.3.6.1.4.1.674.10892.1.1600.110.1.4
Description
Defines the support information index that references the trouble ticket.
Syntax
DellUnsigned32BitRange
Access
Read-write
COO Trouble Ticket Number Name
384
Name
cooTroubleTicketNumberName
Object ID
1.3.6.1.4.1.674.10892.1.1600.110.1.5
Description
Defines the trouble ticket number for this system.
Syntax
DellCostofOwnershipString
Access
Read-write
Cost of Ownership Group
Cost of Ownership Variable Values
This section includes definitions for server administrator-specific variable values used in this section.
Table 18-1.
COO Ownership Codes
Variable Name: DellCooOwnershipCodes
Data Type: Integer
Possible Data Values
Meaning of Data Value
other(1)
The ownership code is not one of following:
unknown(2)
The ownership code is unknown.
owned(3)
The ownership code is owned.
leased(4)
The ownership code is leased.
rented(5)
The ownership code is rented.
offOfLease(6)
The ownership code is off of lease.
transfer(7)
The ownership code is transfer.
Table 18-2.
COO Hour Day Duration Type
Variable Name: DellCooHourDayDurationType
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
Duration time type is unknown.
hours(2)
Duration time type is in hours.
days(3)
Duration time type is in days.
Cost of Ownership Group
385
Table 18-3.
COO Day Month Duration Type
Variable Name: DellCooDayMonthDurationType
Data Type: Integer
Possible Data Values
Meaning of Data Value
unknown(1)
Duration time type is unknown.
days(3)
Duration time type is in days.
months(4)
Duration time type is in months.
Table 18-4.
COO Month Year Duration Type
Variable Name: DellCooMonthYearDurationType
Data Type: Integer
386
Possible Data Values
Meaning of Data Value
unknown(1)
Duration time type is unknown.
months(4)
Duration time type is in months.
years(5)
Duration time type is in years.
Cost of Ownership Group
Remote Access Group
The Remote Access Group provides information about the remote access hardware that may be
present in your system. In addition to providing general information about the capabilities and
settings of the remote access hardware, this group provides information about administrative users,
SNMP trap destinations, modem configuration for dial-up networking, dial-in configuration,
and dial-out destinations.
DRAC 4 and DRAC 5
On systems with Dell™ Remote Access Controller (DRAC) 4 or DRAC 5, the Remote Access Group
includes only the Remote Access Table.
Remote Access Table
The following MIB object sets up the Remote Access Table.
Name
remoteAccessTable
Object ID
1.3.6.1.4.1.674.10892.1.1700.10
Description
Defines the Remote Access Table.
Syntax
SEQUENCE OF RemoteAccessTableEntry
Access
Not accessible
Remote Access Table Entry
Name
remoteAccessTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1
Description
Defines the Remote Access Table entry.
Syntax
RemoteAccessTableEntry
Access
Not accessible
Index
remoteAccessChassisIndex, remoteAccessAdapterIndex
Remote Access Group
387
Remote Access Chassis Index
Name
remoteAccessChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.1
Description
Defines the index (one-based) of the chassis containing the remote
access hardware.
Syntax
DellObjectRange
Access
Read-only
Remote Access Adapter Index
Name
remoteAccessAdapterIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.2
Description
Defines the index (one-based) of the remote access hardware.
Syntax
DellObjectRange
Access
Read-only
Remote Access Type
Name
remoteAccessType
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.3
Description
Defines the type of remote access hardware.
Syntax
DellRemoteAccessType (See Table 19-1.)
Access
Read-only
Remote Access State Capabilities
388
Name
remoteAccessStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.4
Description
Defines the state capabilities of the remote access hardware.
Syntax
DellStateCapabilities
Access
Read-only
Remote Access Group
Remote Access State Settings
Name
remoteAccessStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.5
Description
Defines the state setting of the remote access hardware.
Syntax
DellStateSettings
Access
Read-write
Remote Access Status
Name
remoteAccessStatus
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.6
Description
Defines the status of the remote access hardware.
Syntax
DellStatus
Access
Read-only
Remote Access Product Info Name
Name
remoteAccessProductInfoName
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.7
Description
Defines the name of the product providing the remote access
functionality.
Syntax
DellDisplayString (SIZE (0..63))
Access
Read-only
Remote Access Description Info Name
Name
remoteAccessDescriptionInfoName
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.8
Description
Defines the description of the product providing the remote access
functionality.
Syntax
DellDisplayString (SIZE (0..255))
Access
Read-only
Remote Access Group
389
Remote Access Version Info Name
Name
remoteAccessVersionInfoName
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.9
Description
Defines the version of the product providing the remote access
functionality.
Syntax
DellDisplayString (SIZE (0..63))
Access
Read-only
Remote Access Local Area Network (LAN) Capabilities
Name
remoteAccessLANCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.14
Description
Defines the LAN capabilities of the remote access hardware.
Syntax
DellRemoteAccessLANCapabilities (See Table 19-6.)
Access
Read-only
Remote Access LAN Settings
Name
remoteAccessLANSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.15
Description
Defines the LAN settings of the remote access hardware.
Syntax
DellRemoteAccessLANSettings (See Table 19-7.)
Access
Read-write
Remote Access Network Interface Controller (NIC) Static IP Address
390
Name
remoteAccessNICStaticIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.25
Description
Defines the static IP address to be used by the integrated NIC
provided by the remote access hardware.
Syntax
IpAddress
Access
Read-write
Remote Access Group
Remote Access NIC Static Netmask Address
Name
remoteAccessNICStaticNetmaskAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.26
Description
Defines the netmask for the static IP address to be used by the
integrated NIC provided by the remote access hardware.
Syntax
IpAddress
Access
Read-write
Remote Access NIC Static Gateway Address
Name
remoteAccessNICStaticGatewayAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.27
Description
Defines the IP address for the gateway associated with the static
IP address to be used by the integrated NIC provided by the
remote access hardware.
Syntax
IpAddress
Access
Read-write
Remote Access Personal Computer Memory Card International Association (PCMCIA) Info Name
Name
remoteAccessPCMCIAInfoName
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.28
Description
Defines the information for the PCMCIA device used by the
remote access hardware.
Syntax
DisplayString (SIZE (0..63))
Access
Read-only
Remote Access Miscellaneous Information Name
Name
remoteAccessMiscInfoName
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.29
Description
Defines the miscellaneous information for the remote access hardware.
Syntax
DisplayString (SIZE (0..63))
Access
Read-write
Remote Access Group
391
Remote Access NIC Current IP Address
Name
remoteAccessNICCurrentIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.30
Description
Defines the IP address currently being used by the integrated NIC
provided by the remote access hardware.
Syntax
IpAddress
Access
Read-only
Remote Access NIC Current Netmask Address
Name
remoteAccessNICCurrentNetmaskAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.31
Description
Defines the netmask currently being used by the integrated NIC
provided by the remote access hardware.
Syntax
IpAddress
Access
Read-only
Remote Access NIC Current Gateway Address
Name
remoteAccessNICCurrentGatewayAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.32
Description
Defines the IP address for the gateway currently being used by the
integrated NIC provided by the remote access hardware.
Syntax
IpAddress
Access
Read-only
Remote Access NIC Current Information From Dynamic Host Configuration Protocol (DHCP)
392
Name
remoteAccessNICCurrentInfoFromDHCP
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.33
Description
Defines whether DHCP was used to obtain the NIC information
currently being used by the integrated NIC provided by the remote
access hardware.
Syntax
DellBoolean
Access
Read-only
Remote Access Group
Remote Access Remote Connect URL
Name
remoteAccessRemoteConnectURL
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.34
Description
Defines the URL for launching the Remote Access Remote Connect Interface.
Syntax
DisplayString (SIZE (0..63))
Access
Mandatory
DRAC III
On systems with DRAC III, the Remote Access Group includes the following MIB tables:
•
Remote Access Table
•
Remote User Administration Table
•
Remote SNMP Trap Table
•
Remote Dial-Up Table
•
Remote User Dial-In Configuration Table
•
Remote Dial-Out Table
Remote Access Table
The following MIB object sets up the Remote Access Table.
Name
remoteAccessTable
Object ID
1.3.6.1.4.1.674.10892.1.1700.10
Description
Defines the Remote Access Table.
Syntax
SEQUENCE OF RemoteAccessTableEntry
Access
Not accessible
Remote Access Table Entry
Name
remoteAccessTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1
Description
Defines the Remote Access Table entry.
Syntax
RemoteAccessTableEntry
Access
Not accessible
Index
remoteAccessChassisIndex, remoteAccessAdapterIndex
Remote Access Group
393
Remote Access Chassis Index
Name
remoteAccessChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.1
Description
Defines the index (one-based) of the chassis containing the remote
access hardware.
Syntax
DellObjectRange
Access
Read-only
Remote Access Adapter Index
Name
remoteAccessAdapterIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.2
Description
Defines the index (one-based) of the remote access hardware.
Syntax
DellObjectRange
Access
Read-only
Remote Access Type
Name
remoteAccessType
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.3
Description
Defines the type of remote access hardware.
Syntax
DellRemoteAccessType (See Table 19-1.)
Access
Read-only
Remote Access State Capabilities
394
Name
remoteAccessStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.4
Description
Defines the state capabilities of the remote access hardware.
Syntax
DellStateCapabilities
Access
Read-only
Remote Access Group
Remote Access State Settings
Name
remoteAccessStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.5
Description
Defines the state setting of the remote access hardware.
Syntax
DellStateSettings
Access
Read-write
Remote Access Status
Name
remoteAccessStatus
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.6
Description
Defines the status of the remote access hardware.
Syntax
DellStatus
Access
Read-only
Remote Access Product Info Name
Name
remoteAccessProductInfoName
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.7
Description
Defines the name of the product providing the remote access functionality.
Syntax
DellDisplayString (SIZE (0..63))
Access
Read-only
Remote Access Description Info Name
Name
remoteAccessDescriptionInfoName
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.8
Description
Defines the description of the product providing the remote access functionality.
Syntax
DellDisplayString (SIZE (0..255))
Access
Read-only
Remote Access Group
395
Remote Access Version Info Name
Name
remoteAccessVersionInfoName
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.9
Description
Defines the version of the product providing the remote access functionality.
Syntax
DellDisplayString (SIZE (0..63))
Access
Read-only
Remote Access Control Capabilities
Name
remoteAccessControlCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.10
Description
Defines the control capabilities of the remote access hardware.
Syntax
DellRemoteAccessControlCapabilities (See Table 19-2.)
Access
Read-only
Remote Access Control Settings
Name
remoteAccessControlSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.11
Description
Defines the control settings of the remote access hardware.
Syntax
DellRemoteAccessControlSettings (See Table 19-3.)
Access
Read-write
Remote Access Monitor Capabilities
396
Name
remoteAccessMonitorCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.12
Description
Defines the monitor capabilities of the remote access hardware.
Syntax
DellRemoteAccessMonitorCapabilities (See Table 19-4.)
Access
Read-only
Remote Access Group
Remote Access Monitor Settings
Name
remoteAccessMonitorSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.13
Description
Defines the monitor settings of the remote access hardware.
Syntax
DellRemoteAccessMonitorSettings (See Table 19-5)
Access
Read-write
Remote Access Local Area Network (LAN) Capabilities
Name
remoteAccessLANCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.14
Description
Defines the LAN capabilities of the remote access hardware.
Syntax
DellRemoteAccessLANCapabilities (See Table 19-6.)
Access
Read-only
Remote Access LAN Settings
Name
remoteAccessLANSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.15
Description
Defines the LAN settings of the remote access hardware.
Syntax
DellRemoteAccessLANSettings (See Table 19-7.)
Access
Read-write
Remote Access Host Capabilities
Name
remoteAccessHostCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.16
Description
Defines the host capabilities of the remote access hardware.
Syntax
DellRemoteAccessHostCapabilities (See Table 19-8.)
Access
Read-only
Remote Access Group
397
Remote Access Host Settings
Name
remoteAccessHostSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.17
Description
Defines the host settings of the remote access hardware.
Syntax
DellRemoteAccessHostSettings (See Table 19-9.)
Access
Read-write
Remote Access Out-of-Band Simple Network Management Protocol (SNMP) Capabilities
Name
remoteAccessOutOfBandSNMPCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.18
Description
Defines the out-of-band SNMP capabilities of the remote access hardware.
Syntax
DellRemoteAccessOutOfBandSNMPCapabilities (See Table 19-10.)
Access
Read-only
Remote Access Out-of-Band SNMP Settings
Name
remoteAccessOutOfBandSNMPSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.19
Description
Defines the out-of-band SNMP settings of the remote access hardware.
Syntax
DellRemoteAccessOutOfBandSNMPSettings (See Table 19-11.)
Access
Read-write
Remote Access Simple Mail Transfer Protocol (SMTP) Server Internet Protocol (IP) Address
398
Name
remoteAccessSMTPServerIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.20
Description
Defines the IP address for the SMTP server used by the remote access hardware.
Syntax
IpAddress
Access
Read-write
Remote Access Group
Remote Access Floppy Trivial File Transfer Protocol (TFTP) IP Address
Name
remoteAccessFloppyTFTPIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.21
Description
Defines the IP address of the TFTP server providing the operating
system image used by the remote access hardware.
Syntax
IpAddress
Access
Read-write
Remote Access Floppy TFTP Path Name
Name
remoteAccessFloppyTFTPPathName
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.22
Description
Defines the file name of the operating system image obtained from
the TFTP server used by the remote access hardware.
Syntax
DisplayString (SIZE (0..255))
Access
Read-write
Remote Access Firmware Update IP Address
Name
remoteAccessFirmwareUpdateIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.23
Description
Defines the IP address of the update server providing the firmware
image used by the remote access hardware.
Syntax
IpAddress
Access
Read-write
Remote Access Firmware Update Path Name
Name
remoteAccessFirmwareUpdatePathName
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.24
Description
Defines the file name of the firmware image obtained from the
update server used by the remote access hardware.
Syntax
DisplayString (SIZE (0..255))
Access
Read-write
Remote Access Group
399
Remote Access Network Interface Controller (NIC) Static IP Address
Name
remoteAccessNICStaticIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.25
Description
Defines the static IP address to be used by the integrated NIC
provided by the remote access hardware.
Syntax
IpAddress
Access
Read-write
Remote Access NIC Static Netmask Address
Name
remoteAccessNICStaticNetmaskAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.26
Description
Defines the netmask for the static IP address to be used by the
integrated NIC provided by the remote access hardware.
Syntax
IpAddress
Access
Read-write
Remote Access NIC Static Gateway Address
Name
remoteAccessNICStaticGatewayAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.27
Description
Defines the IP address for the gateway associated with the static
IP address to be used by the integrated NIC provided by the
remote access hardware.
Syntax
IpAddress
Access
Read-write
Remote Access Personal Computer Memory Card International Association (PCMCIA) Info Name
400
Name
remoteAccessPCMCIAInfoName
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.28
Description
Defines the information for the PCMCIA device used by the remote
access hardware.
Syntax
DisplayString (SIZE (0..63))
Access
Read-only
Remote Access Group
Remote Access Miscellaneous Information Name
Name
remoteAccessMiscInfoName
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.29
Description
Defines the miscellaneous information for the remote
access hardware.
Syntax
DisplayString (SIZE (0..63))
Access
Read-write
Remote Access NIC Current IP Address
Name
remoteAccessNICCurrentIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.30
Description
Defines the IP address currently being used by the integrated NIC
provided by the remote access hardware.
Syntax
IpAddress
Access
Read-only
Remote Access NIC Current Netmask Address
Name
remoteAccessNICCurrentNetmaskAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.31
Description
Defines the netmask currently being used by the integrated NIC
provided by the remote access hardware.
Syntax
IpAddress
Access
Read-only
Remote Access NIC Current Gateway Address
Name
remoteAccessNICCurrentGatewayAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.32
Description
Defines the IP address for the gateway currently being used by the
integrated NIC provided by the remote access hardware.
Syntax
IpAddress
Access
Read-only
Remote Access Group
401
Remote Access NIC Current Information From Dynamic Host Configuration Protocol (DHCP)
Name
remoteAccessNICCurrentInfoFromDHCP
Object ID
1.3.6.1.4.1.674.10892.1.1700.10.1.33
Description
Defines whether DHCP was used to obtain the NIC information
currently being used by the integrated NIC provided by the
remote access hardware.
Syntax
DellBoolean
Access
Read-only
Remote User Administration Table
Name
remoteUserAdminTable
Object ID
1.3.6.1.4.1.674.10892.1.1700.20
Description
Defines the Remote Access User Administration Table.
Syntax
SEQUENCE OF RemoteUserAdminTableEntry
Access
Not accessible
Remote User Admin Table Entry
Name
remoteUserAdminTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1
Description
Defines the Remote Access User Administration Table entry.
Syntax
RemoteUserAdminTableEntry
Access
Not accessible
Index
remoteUserAdminChassisIndex, remoteUserAdminAdapterIndex,
remoteUserAdminUserIndex
Remote User Admin Chassis Index
402
Name
remoteUserAdminChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.1
Description
Defines the index (one-based) of the chassis containing the
remote access hardware.
Syntax
DellObjectRange
Access
Read-only
Remote Access Group
Remote User Admin Adapter Index
Name
remoteUserAdminAdapterIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.2
Description
Defines the index (one-based) of the remote access hardware used by
this remote access user.
Syntax
DellObjectRange
Access
Read-only
Remote User Admin User Index
Name
remoteUserAdminUserIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.3
Description
Defines the index (one-based) of this remote access user.
Syntax
DellObjectRange
Access
Read-only
Remote User Admin State Capabilities
Name
remoteUserAdminStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.4
Description
Defines the state capabilities for this remote access user.
Syntax
DellRemoteUserAdminStateCapabilities (See Table 19-12.)
Access
Read-only
Remote User Admin State Settings
Name
remoteUserAdminStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.5
Description
Defines the state settings for this remote access user.
Syntax
DellRemoteUserAdminStateSettings (See Table 19-13.)
Access
Read-write
Remote Access Group
403
Remote User Admin Status
Name
remoteUserAdminStatus
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.6
Description
Defines the status for this remote access user.
Syntax
DellStatus
Access
Read-only
Remote User Admin User Name
Name
remoteUserAdminUserName
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.7
Description
Defines the user name for this remote access user.
Syntax
DisplayString (SIZE (0..19))
Access
Read-write
Remote User Admin User Password Name
Name
remoteUserAdminUserPasswordName
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.8
Description
Defines the password for this remote access user.
Syntax
DisplayString (SIZE (0..255))
Access
Read-write
Remote User Admin User Privilege
404
Name
remoteUserAdminUserPrivilege
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.9
Description
Defines the privileges for this remote access user.
Syntax
DisplayString (SIZE (0..31))
Access
Read-write
Remote Access Group
Remote User Admin User Privilege Capabilities
Name
remoteUserAdminUserPrivilegeCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.10
Description
Defines the privilege capabilities for this remote access user.
Syntax
DisplayString (SIZE (0..31))
Access
Read-only
Remote User Admin Alert Filter DRS Events Mask
Name
remoteUserAdminAlertFilterDrsEventsMask
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.11
Description
Defines the DRS events filter mask for this remote access user.
Syntax
DellUnsigned32BitRange
Access
Read-write
Remote User Admin Alert Filter System Events Mask
Name
remoteUserAdminAlertFilterSysEventsMask
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.12
Description
Defines the system events filter mask for this remote access user.
Syntax
DellUnsigned32BitRange
Access
Read-write
Remote User Admin Alert Filter DRS Capabilities
Name
remoteUserAdminAlertFilterDrsCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.13
Description
Defines the DRS events filter capabilities for this remote access user.
Syntax
DellUnsigned32BitRange
Access
Read-only
Remote Access Group
405
Remote User Admin Alert Filter System Capabilities
Name
remoteUserAdminAlertFilterSysCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.14
Description
Defines the system events filter capabilities for this remote access user.
Syntax
DellUnsigned32BitRange
Access
Read-only
Remote User Admin Pager Numeric Number Name
Name
remoteUserAdminPagerNumericNumberName
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.15
Description
Defines the numeric pager number for this remote access user.
Syntax
DisplayString (SIZE (0..95))
Access
Read-write
Remote User Admin Pager Numeric Message Name
Name
remoteUserAdminPagerNumericMessageName
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.16
Description
Defines the message to send to the numeric pager for this remote access user.
Syntax
DisplayString (SIZE (0..31))
Access
Read-write
Remote User Admin Pager Numeric Hang-up Delay
406
Name
remoteUserAdminPagerNumericHangupDelay
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.17
Description
Defines the numeric pager hang-up delay for this remote access user.
Syntax
DellUnsigned32BitRange
Access
Read-write
Remote Access Group
Remote User Admin Pager Alpha Phone Number Name
Name
remoteUserAdminPagerAlphaPhoneNumberName
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.18
Description
Defines the alphanumeric pager phone number for this remote
access user.
Syntax
DisplayString (SIZE (0..95))
Access
Read-write
Remote User Admin Pager Alpha Protocol
Name
remoteUserAdminPagerAlphaProtocol
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.19
Description
Defines the protocol used by the alphanumeric pager provider for
this remote access user.
Syntax
DellRemoteUserAdminAlphaProtocolType (See Table 19-16.)
Access
Read-write
Remote User Admin Pager Alpha Baud Rate
Name
remoteUserAdminPagerAlphaBaudRate
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.20
Description
Defines the baud rate used by the alphanumeric pager provider for
this remote access user.
Syntax
DellRemoteUserAdminAlphaBaudType (See Table 19-17.)
Access
Read-write
Remote User Admin Pager Alpha Custom Message Name
Name
remoteUserAdminPagerAlphaCustomMessageName
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.21
Description
Defines the message to be sent to the alphanumeric pager to inform
the user of a call by this remote access user.
Syntax
DisplayString (SIZE (0..31))
Access
Read-write
Remote Access Group
407
Remote User Admin Pager Alpha Modem Connect Time-out
Name
remoteUserAdminPagerAlphaModemConnectTimeout
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.22
Description
Defines the modem connection time-out for the alphanumeric pager
for this remote access user.
Syntax
DellUnsigned32BitRange
Access
Read-write
Remote User Admin Pager Alpha Pager ID Name
Name
remoteUserAdminPagerAlphaPagerIdName
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.23
Description
Defines the ID to be sent to the alphanumeric pager to inform the
user of a call by this remote access user.
Syntax
DisplayString (SIZE (0..31))
Access
Read-write
Remote User Admin Pager Alpha Password Name
Name
remoteUserAdminPagerAlphaPasswordName
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.24
Description
Defines the password for the alphanumeric pager for this remote
access user.
Syntax
DisplayString (SIZE (0..31))
Access
Read-write
Remote User Admin Pager Modem Init String Name
408
Name
remoteUserAdminPagerModemInitStringName
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.25
Description
Defines the initialization string to be sent to the pager modem for
this remote access user.
Syntax
DisplayString (SIZE (0..31))
Access
Read-write
Remote Access Group
Remote User Admin Pager Modem Port
Name
remoteUserAdminPagerModemPort
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.26
Description
Defines the port for the pager modem for this remote access user.
Syntax
DellUnsigned32BitRange
Access
Read-write
Remote User Admin E-Mail Address Name
Name
remoteUserAdminEmailAddressName
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.27
Description
Defines the e-mail address for this remote access user.
Syntax
DisplayString (SIZE (0..63))
Access
Read-write
Remote User Admin E-Mail Custom Message Name
Name
remoteUserAdminEmailCustomMessageName
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.28
Description
Defines the e-mail message to send to this remote access user.
Syntax
DisplayString (SIZE (0..31))
Access
Read-write
Remote User Admin Control Capabilities
Name
remoteUserAdminControlCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.29
Description
Defines the control capabilities for this remote access user.
Syntax
DellRemoteUserAdminControlCapabilities (See Table 19-14.)
Access
Read-only
Remote Access Group
409
Remote User Admin Control Settings
Name
remoteUserAdminControlSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.30
Description
Defines the control settings for this remote access user.
Syntax
DellRemoteUserAdminControlSettings (See Table 19-15.)
Access
Read-write
Remote User Admin User Type
Name
remoteUserAdminUserType
Object ID
1.3.6.1.4.1.674.10892.1.1700.20.1.31
Description
Defines the type of user for this remote access user.
Syntax
DellUnsigned8BitRange
Access
Read-write
Remote SNMP Trap Table
Name
remoteSNMPTrapTable
Object ID
1.3.6.1.4.1.674.10892.1.1700.30
Description
Defines the Remote Access SNMP Trap Destination Table.
Syntax
SEQUENCE OF RemoteSNMPTrapTableEntry
Access
Not accessible
Remote SNMP Trap Table Entry
410
Name
remoteSNMPTrapTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1
Description
Defines the Remote Access SNMP Trap Destination Table entry.
Syntax
RemoteSNMPTrapTableEntry
Access
Not accessible
Index
remoteSNMPTrapChassisIndex, remoteSNMPTrapAdapterIndex,
remoteSNMPTrapIndex
Remote Access Group
Remote SNMP Trap Chassis Index
Name
remoteSNMPTrapChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.1
Description
Defines the index (one-based) of the chassis containing the remote
access hardware.
Syntax
DellObjectRange
Access
Read-only
Remote SNMP Trap Adapter Index
Name
remoteSNMPTrapAdapterIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.2
Description
Defines the index (one-based) of the remote access hardware that
uses this SNMP trap destination.
Syntax
DellObjectRange
Access
Read-only
Remote SNMP Trap Index
Name
remoteSNMPTrapIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.3
Description
Defines the index (one-based) of this remote access SNMP trap
destination.
Syntax
DellObjectRange
Access
Read-only
Remote SNMP Trap State Capabilities
Name
remoteSNMPTrapStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.4
Description
Defines the state capabilities of this remote access SNMP trap
destination.
Syntax
DellRemoteSNMPTrapStateCapabilities (See Table 19-18.)
Access
Read-only
Remote Access Group
411
Remote SNMP Trap State Settings
Name
remoteSNMPTrapStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.5
Description
Defines the state settings of this remote access SNMP trap
destination.
Syntax
DellRemoteSNMPTrapStateSettings (See Table 19-19.)
Access
Read-write
Remote SNMP Trap Status
Name
remoteSNMPTrapStatus
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.6
Description
Defines the status of this remote access SNMP trap destination.
Syntax
DellStatus
Access
Read-only
Remote SNMP Trap Destination IP Address
Name
remoteSNMPTrapDestinationIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.7
Description
Defines the IP address of this remote access SNMP trap destination.
Syntax
IpAddress
Access
Read-write
Remote SNMP Trap SNMP Community Name
412
Name
remoteSNMPTrapSNMPCommunityName
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.8
Description
Defines the community for traps sent to this remote access
SNMP trap destination.
Syntax
DisplayString (SIZE (0..31))
Access
Read-write
Remote Access Group
Remote SNMP Trap Filter DRS Events Mask
Name
remoteSNMPTrapFilterDrsEventsMask
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.9
Description
Defines the DRS events filter mask for this remote access
SNMP trap destination.
Syntax
DellUnsigned32BitRange
Access
Read-write
Remote SNMP Trap Filter System Events Mask
Name
remoteSNMPTrapFilterSysEventsMask
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.10
Description
Defines the system events filter mask for this remote access
SNMP trap destination.
Syntax
DellUnsigned32BitRange
Access
Read-write
Remote SNMP Trap Filter DRS Capabilities
Name
remoteSNMPTrapFilterDrsCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.11
Description
Defines the DRS events filter capabilities for this remote access
SNMP trap destination.
Syntax
DellUnsigned32BitRange
Access
Read-only
Remote SNMP Trap Filter System Capabilities
Name
remoteSNMPTrapFilterSysCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.12
Description
Defines the system events filter capabilities of this remote access
SNMP trap destination.
Syntax
DellUnsigned32BitRange
Access
Read-only
Remote Access Group
413
Remote SNMP Trap Control Capabilities
Name
remoteSNMPTrapControlCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.13
Description
Defines the control capabilities of this remote access
SNMP trap destination.
Syntax
DellRemoteSNMPTrapControlCapabilities (See Table 19-20.)
Access
Read-only
Remote SNMP Trap Control Settings
Name
remoteSNMPTrapControlSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.30.1.14
Description
Defines the control settings of this remote access SNMP
trap destination.
Syntax
DellRemoteSNMPTrapControlSettings (See Table 19-21.)
Access
Read-write
Remote Dial-Up Table
Name
remoteDialUpTable
Object ID
1.3.6.1.4.1.674.10892.1.1700.40
Description
Defines the Remote Access Dial-Up Table.
Syntax
SEQUENCE OF RemoteDialUpTableEntry
Access
Not accessible
Remote Dial-Up Table Entry
414
Name
remoteDialUpTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1
Description
Defines the Remote Access Dial-Up Table entry.
Syntax
RemoteDialUpTableEntry
Access
Not accessible
Index
remoteDialUpChassisIndex, remoteDialUpAdapterIndex,
remoteDialUpIndex
Remote Access Group
Remote Dial-Up Chassis Index
Name
remoteDialUpChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.1
Description
Defines the index (one-based) of the chassis containing the remote
access hardware.
Syntax
DellObjectRange
Access
Read-only
Remote Dial-Up Adapter Index
Name
remoteDialUpAdapterIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.2
Description
Defines the index (one-based) of the remote access hardware that
supports this remote access dial-up functionality.
Syntax
DellObjectRange
Access
Read-only
Remote Dial-Up Index
Name
remoteDialUpIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.3
Description
Defines the index (one-based) of this remote access dial-up
functionality.
Syntax
DellObjectRange
Access
Read-only
Remote Dial-Up State Capabilities
Name
remoteDialUpStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.4
Description
Defines the state capabilities of this remote access dial-up
functionality.
Syntax
DellRemoteDialUpStateCapabilities (See Table 19-22.)
Access
Read-only
Remote Access Group
415
Remote Dial-Up State Settings
Name
remoteDialUpStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.5
Description
Defines the state settings of this remote access dial-up functionality.
Syntax
DellRemoteDialUpStateSettings (See Table 19-23.)
Access
Read-write
Remote Dial-Up Status
Name
remoteDialUpStatus
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.6
Description
Defines the status of this remote access dial-up functionality.
Syntax
DellStatus
Access
Read-only
Remote Dial-Up PPP Dial-In Base IP Address
Name
remoteDialUpPPPDialInBaseIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.7
Description
Defines the base IP address of the PPP server for this remote access
dial-up functionality.
Syntax
IpAddress
Access
Read-write
Remote Dial-Up PPP Dial-In Idle Time-out
416
Name
remoteDialUpPPPDialInIdleTimeout
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.8
Description
Defines the PPP idle time-out value in seconds for this remote access
dial-up functionality.
Syntax
DellUnsigned32BitRange
Access
Read-write
Remote Access Group
Remote Dial-Up PPP Dial-In Maximum Connection Time-out
Name
remoteDialUpPPPDialInMaxConnectTimeout
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.9
Description
Defines the PPP connect time-out value in seconds for this remote
access dial-up functionality.
Syntax
DellUnsigned32BitRange
Access
Read-write
Remote Dial-Up Dial-Out Modem Connect Time-out
Name
remoteDialUpDialOutModemConnectTimeout
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.10
Description
Defines the modem dial-out time-out value in seconds for this
remote access dial-up functionality.
Syntax
DellUnsigned32BitRange
Access
Read-write
Remote Dial-Up Modem Dial Type
Name
remoteDialUpModemDialType
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.11
Description
Defines the dial type for the modem used by this remote access
dial-up functionality.
Syntax
DellRemoteDialUpModemDialType (SeeTable 19-24.)
Access
Read-write
Remote Dial-Up Modem Init String Name
Name
remoteDialUpModemInitStringName
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.12
Description
Defines the initialization string to be sent to the modem for this
remote access dial-up functionality.
Syntax
DisplayString (SIZE (0..63))
Access
Read-write
Remote Access Group
417
Remote Dial-Up Modem Baud Rate
Name
remoteDialUpModemBaudRate
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.13
Description
Defines the baud rate for the modem used by this remote access
dial-up functionality.
Syntax
DellUnsigned32BitRange
Access
Read-write
Remote Dial-Up Modem Port
Name
remoteDialUpModemPort
Object ID
1.3.6.1.4.1.674.10892.1.1700.40.1.14
Description
Defines the port for the modem used by this remote access dial-up
functionality.
Syntax
DellUnsigned32BitRange
Access
Read-write
Remote User Dial-In Configuration Table
Name
remoteUserDialInCfgTable
Object ID
1.3.6.1.4.1.674.10892.1.1700.50
Description
Defines the Remote Access User Dial-In Configuration Table.
Syntax
SEQUENCE OF RemoteUserDialInCfgTableEntry
Access
Not accessible
Remote User Dial-In Configuration Table Entry
418
Name
remoteUserDialInCfgTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1700.50.1
Description
Defines the Remote Access User Dial-In Configuration Table entry.
Syntax
RemoteUserDialInCfgTableEntry
Access
Not accessible
Index
remoteUserDialInCfgChassisIndex,
remoteUserDialInCfgAdapterIndex,
remoteUserDialInCfgUserIndex
Remote Access Group
Remote User Dial-In Configuration Chassis Index
Name
remoteUserDialInCfgChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.50.1.1
Description
Defines the index (one-based) of the chassis containing the remote
access hardware.
Syntax
DellObjectRange
Access
Read-only
Remote User Dial-In Configuration Adapter Index
Name
remoteUserDialInCfgAdapterIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.50.1.2
Description
Defines the index (one-based) of the remote access hardware that
supports this remote access dial-in user.
Syntax
DellObjectRange
Access
Read-only
Remote User Dial-In Configuration User Index
Name
remoteUserDialInCfgUserIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.50.1.3
Description
Defines the index (one-based) of this remote access dial-in user.
Syntax
DellObjectRange
Access
Read-only
Remote User Dial-In Configuration State Capabilities
Name
remoteUserDialInCfgStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.50.1.4
Description
Defines the state capabilities of this remote access dial-in user.
Syntax
DellRemoteUserDialInStateCapabilities (See Table 19-25.)
Access
Read-only
Remote Access Group
419
Remote User Dial-In Configuration State Settings
Name
remoteUserDialInCfgStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.50.1.5
Description
Defines the state settings of this remote access dial-in user.
Syntax
DellRemoteUserDialInStateSettings (See Table 19-26.)
Access
Read-write
Remote User Dial-In Configuration Status
Name
remoteUserDialInCfgStatus
Object ID
1.3.6.1.4.1.674.10892.1.1700.50.1.6
Description
Defines the status of this remote access dial-in user.
Syntax
DellStatus
Access
Read-only
Remote User Dial-In Configuration PPP Username
Name
remoteUserDialInCfgPPPUserName
Object ID
1.3.6.1.4.1.674.10892.1.1700.50.1.7
Description
Defines the PPP user name of this remote access dial-in user.
Syntax
DisplayString (SIZE (0..15))
Access
Read-write
Remote User Dial-In Configuration PPP User Password Name
420
Name
remoteUserDialInCfgPPPUserPasswordName
Object ID
1.3.6.1.4.1.674.10892.1.1700.50.1.8
Description
Defines the PPP password of this remote access dial-in user.
Syntax
DisplayString (SIZE (0..15))
Access
Read-write
Remote Access Group
Remote User Dial-In Configuration Callback Phone Number Name
Name
remoteUserDialInCfgCallbackPhoneNumberName
Object ID
1.3.6.1.4.1.674.10892.1.1700.50.1.9
Description
Defines the callback phone number for this remote access dial-in user.
Syntax
DisplayString (SIZE (0..95))
Access
Read-write
Remote Dial-Out Table
Name
remoteDialOutTable
Object ID
1.3.6.1.4.1.674.10892.1.1700.60
Description
Defines the Remote Access Dial-Out Table.
Syntax
SEQUENCE of RemoteDialOutTableEntry
Access
Not accessible
Remote Dial-Out Table Entry
Name
remoteDialOutTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1700.60.1
Description
Defines the Remote Access Dial-Out Table entry.
Syntax
RemoteDialOutTableEntry
Access
Not accessible
Index
remoteDialOutChassisIndex, remoteDialOutAdapterIndex,
remoteDialOutDialOutIndex
Remote Dial-Out Chassis Index
Name
remoteDialOutChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.60.1.1
Description
Defines the index (one-based) of the chassis containing the remote
access hardware.
Syntax
DellObjectRange
Access
Read-only
Remote Access Group
421
Remote Dial-Out Adapter Index
Name
remoteDialOutAdapterIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.60.1.2
Description
Defines the index (one-based) of the remote access hardware that
supports this remote access dial-out functionality.
Syntax
DellObjectRange
Access
Read-only
Remote Dial-Out Dial-Out Index
Name
remoteDialOutDialOutIndex
Object ID
1.3.6.1.4.1.674.10892.1.1700.60.1.3
Description
Defines the index (one-based) of this remote access dial-out functionality.
Syntax
DellObjectRange
Access
Read-only
Remote Dial-Out State Capabilities
Name
remoteDialOutStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1700.60.1.4
Description
Defines the state capabilities of this remote access dial-out functionality.
Syntax
DellRemoteDialOutStateCapabilities (See Table 19-27.)
Access
Read-only
Remote Dial-Out State Settings
422
Name
remoteDialOutStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1700.60.1.5
Description
Defines the state settings of this remote access dial-out functionality.
Syntax
DellRemoteDialOutStateSettings (See Table 19-28.)
Access
Read-write
Remote Access Group
Remote Dial-Out Status
Name
remoteDialOutStatus
Object ID
1.3.6.1.4.1.674.10892.1.1700.60.1.6
Description
Defines the status of this remote access dial-out functionality.
Syntax
DellStatus
Access
Read-only
Remote Dial-Out IP Address
Name
remoteDialOutIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1700.60.1.7
Description
Defines the IP address for this remote access dial-out destination.
Syntax
IpAddress
Access
Read-write
Remote Dial-Out Phone Number Name
Name
remoteDialOutPhoneNumberName
Object ID
1.3.6.1.4.1.674.10892.1.1700.60.1.8
Description
Defines the phone number for this remote access dial-out destination.
Syntax
DisplayString (SIZE (0..95))
Access
Read-write
Remote Dial-Out PPP Username
Name
remoteDialOutPPPUserName
Object ID
1.3.6.1.4.1.674.10892.1.1700.60.1.9
Description
Defines the PPP username for this remote access dial-out destination.
Syntax
DisplayString (SIZE (0..31))
Access
Read-write
Remote Access Group
423
Remote Dial-Out PPP Password Name
Name
remoteDialOutPPPPasswordName
Object ID
1.3.6.1.4.1.674.10892.1.1700.60.1.10
Description
Defines the PPP password for this remote access dial-out destination.
Syntax
DisplayString (SIZE (0..31))
Access
Read-write
Remote Access Variable Values
This section includes definitions for server administrator-specific variable values used in this section.
Table 19-1.
Remote Access Type
Variable Name: DellRemoteAccessType
Data Type: Integer
Possible Data Values
Meaning of Data Value
remoteAccessTypeIsOther(1)
The remote access type is not one of the following:
remoteAccessTypeIsUnknown(2)
The remote access type is unknown.
remoteAccessTypeIsDRACIII(3)
The remote access type is DRAC III.
remoteAccessTypeIsERA(4)
The remote access type is ERA.
Table 19-2.
Remote Access Control Capabilities
Variable Name: DellRemoteAccessControlCapabilities
Data Type: Integer
424
Possible Data Values
Meaning of Data Value
none(0)
The remote access hardware has no control capabilities.
unknownCapabilities(1)
The remote access hardware control capabilities are unknown.
logResetCapable(2)
The remote access hardware can reset its integrated logs.
hardResetCapable(4)
The remote access hardware can perform a hard reset.
softResetCapable(8)
The remote access hardware can perform a soft reset.
gracefulResetCapable(16)
The remote access hardware can gracefully shut down and
perform a soft reset.
defaultConfigResetCapable(32)
The remote access hardware can reset to its default settings.
shutdownCapable(64)
The remote access hardware can shut down.
Remote Access Group
Table 19-3.
Remote Access Control Settings
Variable Name: DellRemoteAccessControlSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The remote access hardware has no control settings.
unknown(1)
The remote access hardware control settings are unknown.
logReset(2)
The remote access hardware will reset its integrated logs.
hardReset(4)
The remote access hardware will perform a hard reset.
softReset(8)
The remote access hardware will perform a soft reset.
gracefulReset(16)
The remote access hardware will gracefully shut down and
perform a soft reset.
defaultConfigReset(32)
The remote access hardware will reset to its default settings.
shutdown(64)
The remote access hardware will shut down.
Table 19-4.
Remote Access Monitor Capabilities
Variable Name: DellRemoteAccessMonitorCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The remote access hardware has no monitor capabilities.
unknownCapabilities(1)
The remote access hardware monitor capabilities are unknown.
extPwrSupplyMonitorIfConnectedCap The remote access hardware can be set to monitor the external
able(2)
power supply, if connected.
extPwrSupplyMonitorAlwaysEnabledCap The remote access hardware can be set to always monitor the
able(4)
external power supply.
Remote Access Group
425
Table 19-5.
Remote Access Monitor Settings
Variable Name: DellRemoteAccessMonitorSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The remote access hardware has no monitor settings.
unknown(1)
The remote access hardware monitor settings are unknown.
extPwrSupplyMonitorIfConnected
Enabled(2)
The remote access hardware will monitor the external power supply,
if connected.
extPwrSupplyMonitorAlwaysEnabled The remote access hardware will always monitor the external power
Enabled(4)
supply.
Table 19-6.
Remote Access Local Area Network (LAN) Capabilities
Variable Name: DellRemoteAccessLANCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The remote access hardware has no LAN capabilities.
unknownCapabilities(1)
The remote access hardware LAN capabilities are unknown.
nicCapable(2)
The remote access hardware has a network interface controller
(NIC).
nicDHCPCapable(4)
The remote access hardware NIC can use DHCP to obtain an
IP address.
Table 19-7.
Remote Access LAN Settings
Variable Name: DellRemoteAccessLANSettings
Data Type: Integer
426
Possible Data Values
Meaning of Data Value
none(0)
The remote access hardware has no LAN settings.
unknown(1)
The remote access hardware LAN settings are unknown.
nicEnabled(2)
The remote access hardware NIC is enabled.
nicDHCPEnabled(4)
The remote access hardware NIC will use DHCP to obtain an
IP address.
Remote Access Group
Table 19-8.
Remote Access Host Capabilities
Variable Name: DellRemoteAccessHostCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The remote access hardware has no host capabilities.
unknownCapabilities(1)
The remote access hardware host capabilities are unknown.
smtpEmailCapable(2)
The remote access hardware
supports sending e-mail using SMTP.
tftpRemoteFloppyCapable(4)
The remote access hardware supports remote floppy boot using
a TFTP server.
tftpRemoteFwUpdateCapable(8)
The remote access hardware supports remote firmware update
using a TFTP server.
Table 19-9.
Remote Access Host Settings
Variable Name: DellRemoteAccessHostSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The remote access hardware has no host settings.
unknown(1)
The remote access hardware host settings are unknown.
smtpEmailEnabled(2)
The remote access hardware SMTP client is enabled for
sending e-mail.
tftpRemoteFloppyEnabled(4)
The remote access hardware TFTP client is enabled for
remote floppy boot.
tftpRemoteFwUpdateEnabled(8)
The remote access hardware TFTP client is enabled for
remote firmware update.
Remote Access Group
427
Table 19-10. Remote Access Out-Of-Band Simple Network Management Protocol (SNMP) Capabilities
Variable Name: DellRemoteAccessOutOfBandSNMPCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The remote access hardware has no out-of-band SNMP capabilities.
unknownCapabilities(1)
The remote access hardware out-of-band SNMP capabilities are unknown.
oobSNMPAgentCapable(2)
The remote access hardware has an out-of-band SNMP agent.
oobSNMPTrapsCapable(4)
The remote access hardware can send out-of-band SNMP traps.
Table 19-11. Remote Access Out-Of-Band Simple Network Management Protocol (SNMP) Settings
Variable Name: DellRemoteAccessOutOfBandSNMPSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The remote access hardware has no out-of-band SNMP settings.
unknown(1)
The remote access hardware out-of-band SNMP settings are unknown.
oobSNMPAgentEnabled(2)
The remote access hardware out-of-band SNMP agent is enabled.
oobSNMPTrapsEnabled(4)
The remote access hardware will send out-of-band SNMP traps.
Table 19-12. Remote User Admin State Capabilities
Variable Name: DellRemoteUserAdminStateCapabilities
Data Type: Integer
428
Possible Data Values
Meaning of Data Value
none(0)
The admin user has no state capabilities.
unknownCapabilities(1)
The admin user state capabilities are unknown.
enableCapable(2)
The admin user can be disabled or enabled.
notReadyCapable(4)
The admin user can be in the "not ready" state.
numericPagerCapable(8)
The admin user supports numeric paging.
alphaPagerCapable(16)
The admin user supports alphanumeric paging.
emailCapable(32)
The admin user supports e-mail.
privilegeCapable(64)
The admin user supports user privileges configuration.
Remote Access Group
Table 19-13. Remote User Admin State Settings
Variable Name: DellRemoteUserAdminStateSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The admin user has no state settings.
unknown(1)
The admin user state settings are unknown.
enabled(2)
The admin user is enabled.
notReady(4)
The admin user is in the "not ready" state.
numericPagerEnabled(8)
Numeric paging is enabled for the admin user.
alphaPagerEnabled(16)
Alphanumeric paging is enabled for the admin user.
emailEnabled(32)
E-mail is enabled for the admin user.
Table 19-14. Remote User Admin Control Capabilities
Variable Name: DellRemoteUserAdminControlCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The admin user has no control capabilities.
unknownCapabilities(1)
The admin user control capabilities are unknown.
numericPagerTestCapable(2) The admin user can support sending a test numeric page.
alphaPagerTestCapable(4)
The admin user can support sending a test alphanumeric page.
emailTestCapable(8)
The admin user can support sending a test e-mail.
Table 19-15. Remote User Admin Control Settings
Variable Name: DellRemoteUserAdminControlSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The admin user has no control settings.
unknown(1)
The admin user control settings are unknown.
numericPagerTest(2)
A numeric pager test will be performed for the admin user.
alphaPagerTest(4)
An alphanumeric pager test will be performed for the admin user.
emailTest(8)
An e-mail test will be performed for the admin user.
Remote Access Group
429
Table 19-16. Remote User Admin Alpha Protocol Type
Variable Name: DellRemoteUserAdminAlphaProtocolType
Data Type: Integer
Possible Data Values
Meaning of Data Value
other(1)
The remote user admin alpha protocol type is not one of the following:
unknown(2)
The remote user admin alpha protocol type is unknown.
alpha7E0(3)
The remote user admin alpha protocol type is 7E0.
alpha8N1(4)
The remote user admin alpha protocol type is 8N1.
Table 19-17. Remote User Admin Alpha Baud Type
Variable Name: DellRemoteUserAdminAlphaBaudType
Data Type: Integer
Possible Data Values
Meaning of Data Value
other(1)
The remote user alphanumeric baud rate is not one of the following:
unknown(2)
The remote user alphanumeric baud rate is unknown.
alphaBaud300(3)
The remote user alphanumeric baud rate is 300.
alphaBaud1200(4)
The remote user alphanumeric baud rate is 1200.
Table 19-18. Remote SNMP Trap State Capabilities
Variable Name: DellRemoteSNMPTrapStateCapabilities
Data Type: Integer
430
Possible Data Values
Meaning of Data Value
none(0)
The SNMP trap destination has no state capabilities.
unknownCapabilities(1)
The SNMP trap destination state capabilities are unknown.
enableCapable(2)
The SNMP trap destination can be disabled or enabled.
notReadyCapable(4)
The SNMP trap destination can be in the "not ready" state.
Remote Access Group
Table 19-19. Remote SNMP Trap State Settings
Variable Name: DellRemoteSNMPTrapStateSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The SNMP trap destination has no state settings.
unknown(1)
The SNMP trap destination state settings are unknown.
enabled(2)
The SNMP trap destination is enabled.
notReady(4)
The SNMP trap destination is in the "not ready" state.
Table 19-20. Remote SNMP Trap Control Capabilities
Variable Name: DellRemoteSNMPTrapControlCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The SNMP trap destination has no control capabilities.
unknownCapabilities(1)
The SNMP trap destination control capabilities are unknown.
trapTestCapable(2)
A SNMP trap test can be performed for the SNMP trap destination.
Table 19-21. Remote SNMP Trap Control Settings
Variable Name: DellRemoteSNMPTrapControlSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The SNMP trap destination has no control settings.
unknown(1)
The SNMP trap destination control settings are unknown.
trapTestCapable(2)
A SNMP trap test will be performed for the SNMP trap destination.
Remote Access Group
431
Table 19-22. Remote Dial-Up State Capabilities
Variable Name: DellRemoteDialUpStateCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The dial-up functionality has no state capabilities.
unknownCapabilities(1)
The dial-up functionality state capabilities are unknown.
enableCapable(2)
The dial-up functionality can be disabled or enabled.
notReadyCapable(4)
The dial-up functionality can be in the "not ready" state.
dialInCapable(8)
The dial-up functionality can support the dial-in feature.
dialOutCapable(16)
The dial-up functionality can support the dial-out feature.
dialInDHCPCapable(32)
The dial-up functionality can support using DHCP to
obtain an IP address for the dial-in feature.
dialInAuthAnyCapable(64)
The dial-up functionality can support any authentication
type (including clear text) for the dial-in feature.
dialInAuthEncryptedCapable(128)
The dial-up functionality can support encrypted passwords
(CHAP) authentication for the dial-in feature.
dialInAuthMschapCapable(256)
The dial-up functionality can support MSCHAP
authentication type for the dial-in feature.
Table 19-23. Remote Dial-Up State Settings
Variable Name: DellRemoteDialUpStateSettings
Data Type: Integer
432
Possible Data Values
Meaning of Data Value
none(0)
The dial-up functionality has no state settings.
unknown(1)
The dial-up functionality state settings are unknown.
enabled(2)
The dial-up functionality is enabled.
notReadyCapable(4)
The dial-up functionality is in the "not ready" state.
dialInEnabled(8)
The dial-up functionality dial-in feature is enabled.
dialOutEnabled(16)
The dial-up functionality dial-out feature is enabled.
Remote Access Group
Table 19-23. Remote Dial-Up State Settings (continued)
Variable Name: DellRemoteDialUpStateSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
dialInDHCPEnabled(32)
The dial-up functionality uses DHCP to obtain an IP
address for the dial-in feature.
dialInAuthAnyEnabled(64)
The dial-up functionality accepts any authentication type
(including clear text) for the dial-in feature.
dialInAuthEncryptedEnabled(128)
The dial-up functionality uses only encrypted passwords
(CHAP) authentication type for the dial-in feature.
dialInAuthMschapEnabled(256)
The dial-up functionality uses only MSCHAP
authentication type for the dial-in feature.
Table 19-24. Remote Dial-Up Modem Dial Type
Variable Name: DellRemoteDialUpModemDialType
Data Type: Integer
Possible Data Values
Meaning of Data Value
remoteDialUpIsOther(1)
The remote dial type is not one of the following:
remoteDialUpIsUnknown(2)
The remote dial type is unknown.
remoteDialUpIsTone(3)
The remote dial type is tone.
remoteDialUpIsPulse(4)
The remote dial type is pulse.
Table 19-25. Remote User Dial-In State Capabilities
Variable Name: DellRemoteUserDialInStateCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The dial-in user has no state capabilities.
unknownCapabilities(1)
The dial-in user state capabilities are unknown.
enableCapable(2)
The dial-in user can be disabled or enabled.
notReadyCapable(4)
The dial-in user can be in the "not ready" state.
dialInCallbackPresetNumberCapable(8)
The dial-in user can support callback using a
preset number.
dialInCallbackUserSpecifiedCapable(16) The dial-in user can support callback using a
user-specified number.
Remote Access Group
433
Table 19-26. Remote User Dial-In State Settings
Variable Name: DellRemoteUserDialInStateSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The dial-in user has no state settings.
unknown(1)
The dial-in user state settings are unknown.
enabled(2)
The dial-in user is enabled.
notReady(4)
The dial-in user is in the "not ready" state.
dialInCallbackPresetNumberEnabled(8)
Callback using a preset number is enabled for the
dial-in user.
dialInCallbackUserSpecifiedEnabled(16) Callback using a user-specified number is enabled for the
dial-in user.
Table 19-27. Remote Dial-Out State Capabilities
Variable Name: DellRemoteDialOutStateCapabilities
Data Type: Integer
434
Possible Data Values
Meaning of Data Value
none(0)
The dial-out destination has no state capabilities.
unknownCapabilities(1)
The dial-out destination state capabilities are unknown.
enableCapable(2)
The dial-out destination can be disabled or enabled.
notReadyCapable(4)
The dial-out destination can be in the "not ready" state.
dialOutPPPAuthAnyCapable(8)
The dial-out destination can support any authentication
type (including clear text) for PPP.
dialOutPPPAuthEncryptedCapable(16)
The dial-out destination can support encrypted passwords
authentication type for PPP.
dialOutPPPAuthMschapCapable(32)
The dial-out destination can support MSCHAP
authentication type for PPP.
Remote Access Group
Table 19-28. Remote Dial-Out State Settings
Variable Name: DellRemoteDialOutStateSettings
Data Type: Integer
Possible Data Values
Meaning of Data Value
none(0)
The dial-out destination has no state settings.
unknown(1)
The dial-out destination state settings are unknown.
enabled(2)
The dial-out destination is disabled or enabled.
notReady(4)
The dial-out destination is in the "not ready" state.
dialOutPPPAuthAnyEnabled(8)
The dial-out destination accepts any authentication type
(including clear text) for PPP.
dialOutPPPAuthEncryptedEnabled(16)
The dial-out destination uses only encrypted passwords
authentication type for PPP.
dialOutPPPAuthMschapEnabled(32)
The dial-out destination uses only MSCHAP
authentication type for PPP.
Remote Access Group
435
436
Remote Access Group
Cluster Group
Clustering combines multiple systems in such a way that they provide services a single system
could not. Clustering enhances higher availability, scalability, and management. Higher availability
is achieved by using "failover" clusters, in which resources can automatically move between two or
more systems in the event of a failure. Scalability is achieved by balancing the load of an application
across several computer systems. Simpler management is achieved by using virtual servers, as
opposed to managing each individual computer system.
Cluster Group
The Cluster Group defines attributes such as the number of systems in the cluster, capabilities of
the cluster, type of cluster, and name of the cluster.
Cluster Table
The following table defines the attributes of the cluster.
Name
clusterTable
Object ID
1.3.6.1.4.1.674.10892.1.1800.10
Description
Defines the Cluster Table.
Syntax
SEQUENCE OF ClusterTableEntry
Access
Not accessible
Cluster Table Entry
Name
clusterTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1800.10.1
Description
Defines the Cluster Table entry.
Syntax
ClusterTableEntry
Access
Not accessible
Index
clusterChassisIndex, clusterIndex
Cluster Group
437
Cluster Chassis Index
Name
clusterChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1800.10.1.1
Description
Defines the index (one-based) of this chassis.
Syntax
DellObjectRange
Access
Read-only
Cluster Index
Name
clusterIndex
Object ID
1.3.6.1.4.1.674.10892.1.1800.10.1.2
Description
Defines the index (one-based) of the cluster.
Syntax
DellObjectRange
Access
Read-only
Cluster State Capabilities
Name
clusterStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1800.10.1.3
Description
Defines the state capabilities of the cluster.
Syntax
DellStateCapabilities
Access
Read-only
Cluster State Settings
438
Name
clusterStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1800.10.1.4
Description
Defines the state settings of the cluster.
Syntax
DellStateSettings
Access
Read-write
Cluster Group
Cluster Status
Name
clusterStatus
Object ID
1.3.6.1.4.1.674.10892.1.1800.10.1.5
Description
Defines the status of the cluster.
Syntax
DellStatus
Access
Read-only
Cluster Type
Name
clusterType
Object ID
1.3.6.1.4.1.674.10892.1.1800.10.1.6
Description
Defines the type of the cluster.
Syntax
DellClusterType
Access
Read-only
Cluster Type Description Name
Name
clusterTypeDescriptionName
Object ID
1.3.6.1.4.1.674.10892.1.1800.10.1.7
Description
Defines the description name for the type of the cluster.
Syntax
DellString
Access
Read-only
Cluster Name
Name
clusterName
Object ID
1.3.6.1.4.1.674.10892.1.1800.10.1.8
Description
Defines the name of the cluster.
Syntax
DellString
Access
Read-only
Cluster Group
439
Cluster Group Variable Values
This section includes definitions for Server Administrator-specific variable values used in this section.
Table 20-1.
Cluster Type
Variable Name: DellClusterType
Data Type: Integer
440
Possible Data Values
Meaning of Data Value
unknown(1)
The cluster type is unknown.
highAvailabilityCluster(2)
The cluster type is a high-availability cluster.
Cluster Group
Baseboard Management Controller Group
The Baseboard Management Controller (BMC) monitors the system for critical events by
communicating with various sensors on the system board and sends alerts and log events when
certain parameters exceed their preset thresholds. The BMC Group provides information about the
BMC that may be present in your system. In addition to providing general information about the
BMC, this group provides information about the serial and local area network (LAN) interfaces
of the BMC.
Baseboard Management Controller Group Tables
The objects in the BMC group define information about the BMC and the serial and LAN interfaces
that can be used to access the BMC remotely to perform management activities. Objects for the
serial interface define the serial connection mode, flow control type and bit rate. Objects for the
LAN interface define the media access control (MAC) address, internet protocol (IP) address,
subnet mask and default gateway.
The following MIB tables define the BMC group:
•
Baseboard Management Controller Table
•
Baseboard Management Controller Serial Interface Table
•
Baseboard Management Controller LAN Interface Table
Baseboard Management Controller Table
Name
bmcTable
Object ID
1.3.6.1.4.1.674.10892.1.1900.10
Description
Defines the Baseboard Management Controller Table.
Syntax
SEQUENCE OF BmcTableEntry
Access
Not accessible
Baseboard Management Controller Group
441
BMC Table Entry
Name
bmcTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1900.10.1
Description
Defines the Baseboard Management Controller (BMC) Table Entry.
Syntax
BmcTableEntry
Access
Not accessible
Index
bmcChassisIndex, bmcIndex
BMC Chassis Index
Name
bmcChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1900.10.1.1
Description
Defines the index (one-based) of the associated chassis.
Syntax
DellObjectRange
Access
Read-only
BMC Index
Name
bmcIndex
Object ID
1.3.6.1.4.1.674.10892.1.1900.10.1.2
Description
Defines the index (one-based) of the BMC.
Syntax
DellObjectRange
Access
Read-only
BMC State Capabilities
442
Name
bmcStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1900.10.1.3
Description
Defines the state capabilities of the BMC.
Syntax
DellStateCapabilities
Access
Read-only
Baseboard Management Controller Group
BMC State Settings
Name
bmcStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1900.10.1.4
Description
Defines the state settings of the BMC.
Syntax
DellStateSettings
Access
Read-write
BMC Status
Name
bmcStatus
Object ID
1.3.6.1.4.1.674.10892.1.1900.10.1.5
Description
Defines the status of the BMC.
Syntax
DellStatus
Access
Read-only
BMC Display Name
Name
bmcDisplayName
Object ID
1.3.6.1.4.1.674.10892.1.1900.10.1.6
Description
Defines the display name of the BMC.
Syntax
DellString
Access
Read-only
BMC Description Name
Name
bmcDescriptionName
Object ID
1.3.6.1.4.1.674.10892.1.1900.10.1.7
Description
Defines the description of the BMC.
Syntax
DisplayString (SIZE (0..255))
Access
Read-only
Baseboard Management Controller Group
443
BMC IPMI Version Name
Name
bmcIPMIVersionName
Object ID
1.3.6.1.4.1.674.10892.1.1900.10.1.8
Description
Defines the version of the Intelligent Platform Management
Interface (IPMI) specification that the BMC supports.
Syntax
DellString
Access
Read-only
BMC GUID
Name
bmcGUID
Object ID
1.3.6.1.4.1.674.10892.1.1900.10.1.9
Description
Defines the Globally Unique ID (GUID) of the BMC.
Syntax
OCTET STRING (SIZE(16))
Access
Read-only
Baseboard Management Controller Serial Interface Table
Name
bmcSerialInterfaceTable
Object ID
1.3.6.1.4.1.674.10892.1.1900.20
Description
Defines the BMC Serial Interface Table.
Syntax
SEQUENCE OF BmcSerialInterfaceTableEntry
Access
Not accessible
BMC Serial Interface Table Entry
444
Name
bmcSerialInterfaceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1900.20.1
Description
Defines the BMC Serial Interface Table Entry.
Syntax
BmcSerialInterfaceTableEntry
Access
Not accessible
Index
bmcSerialInterfaceChassisIndex, bmcSerialInterfaceBMCIndex,
bmcSerialInterfaceIndex
Baseboard Management Controller Group
BMC Serial Interface Chassis Index
Name
bmcSerialInterfaceChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1900.20.1.1
Description
Defines the index (one-based) of the associated chassis.
Syntax
DellObjectRange
Access
Read-only
BMC Serial Interface BMC Index
Name
bmcSerialInterfaceBMCIndex
Object ID
1.3.6.1.4.1.674.10892.1.1900.20.1.2
Description
Defines the index (one-based) of the associated BMC.
Syntax
DellObjectRange
Access
Read-only
BMC Serial Interface Index
Name
bmcSerialInterfaceIndex
Object ID
1.3.6.1.4.1.674.10892.1.1900.20.1.3
Description
Defines the index (one-based) of the BMC serial interface.
Syntax
DellObjectRange
Access
Read-only
BMC Serial Interface State Capabilities
Name
bmcSerialInterfaceStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1900.20.1.4
Description
Defines the state capabilities of the BMC serial interface.
Syntax
DellStateCapabilities
Access
Read-only
Baseboard Management Controller Group
445
BMC Serial Interface State Settings
Name
bmcSerialInterfaceStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1900.20.1.5
Description
Defines the state settings of the BMC serial interface.
Syntax
DellStateSettings
Access
Read-write
BMC Serial Interface Status
Name
bmcSerialInterfaceStatus
Object ID
1.3.6.1.4.1.674.10892.1.1900.20.1.6
Description
Defines the status of the BMC serial interface.
Syntax
DellStatus
Access
Read-only
BMC Serial Interface Channel Number
Name
bmcSerialInterfaceChannelNumber
Object ID
1.3.6.1.4.1.674.10892.1.1900.20.1.7
Description
Defines the BMC channel number of the BMC serial interface.
Syntax
DellUnsigned8BitRange
Access
Read-only
BMC Serial Interface Connection Mode Capabilities
446
Name
bmcSerialInterfaceConnectionModeCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1900.20.1.8
Description
Defines the connection mode capabilities of the BMC serial interface.
Syntax
DellBMCSerialConnectionModeCapabilities
Access
Read-only
Baseboard Management Controller Group
BMC Serial Interface Connection Mode Settings
Name
bmcSerialInterfaceConnectionModeSettings
Object ID
1.3.6.1.4.1.674.10892.1.1900.20.1.9
Description
Defines the connection mode settings of the BMC serial interface.
Syntax
DellBMCSerialConnectionModeSettings
Access
Read-only
BMC Serial Interface Flow Control
Name
bmcSerialInterfaceFlowControl
Object ID
1.3.6.1.4.1.674.10892.1.1900.20.1.10
Description
Defines the flow control type of the BMC serial interface.
Syntax
DellBMCSerialFlowControlType
Access
Read-only
BMC Serial Interface Bit Rate
Name
bmcSerialInterfaceBitRate
Object ID
1.3.6.1.4.1.674.10892.1.1900.20.1.11
Description
Defines the bit rate of the BMC serial interface.
Syntax
DellBMCSerialBitRateType
Access
Read-only
Baseboard Management Controller LAN Interface Table
Name
bmcLANInterfaceTable
Object ID
1.3.6.1.4.1.674.10892.1.1900.30
Description
Defines the Baseboard Management Controller (BMC) LAN Interface Table.
Syntax
SEQUENCE OF BmcLANInterfaceTableEntry
Access
Not accessible
Baseboard Management Controller Group
447
BMC LAN Interface Table Entry
Name
bmcLANInterfaceTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1
Description
Defines the Baseboard Management Controller (BMC) LAN
Interface Table Entry.
Syntax
BmcLANInterfaceTableEntry
Access
Not accessible
Index
bmcLANInterfaceChassisIndex, bmcLANInterfaceBMCIndex,
bmcLANInterfaceIndex
BMC LAN Interface Chassis Index
Name
bmcLANInterfaceChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1.1
Description
Defines the index (one-based) of the associated chassis.
Syntax
DellObjectRange
Access
Read-only
BMC LAN Interface BMC Index
Name
bmcLANInterfaceBMCIndex
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1.2
Description
Defines the index (one-based) of the associated BMC.
Syntax
DellObjectRange
Access
Read-only
BMC LAN Interface Index
448
Name
bmcLANInterfaceIndex
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1.3
Description
Defines the index (one-based) of the BMC LAN interface.
Syntax
DellObjectRange
Access
Read-only
Baseboard Management Controller Group
BMC LAN Interface State Capabilities
Name
bmcLANInterfaceStateCapabilities
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1.4
Description
Defines the state capabilities of the BMC LAN interface.
Syntax
DellStateCapabilities
Access
Read-only
BMC LAN Interface State Settings
Name
bmcLANInterfaceStateSettings
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1.5
Description
Defines the state settings of the BMC LAN interface.
Syntax
DellStateSettings
Access
Read-write
BMC LAN Interface Status
Name
bmcLANInterfaceStatus
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1.6
Description
Defines the status of the BMC LAN interface.
Syntax
DellStatus
Access
Read-only
BMC LAN Interface Channel Number
Name
bmcLANInterfaceChannelNumber
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1.7
Description
Defines the BMC channel number of the BMC LAN interface.
Syntax
DellUnsigned8BitRange
Access
Read-only
Baseboard Management Controller Group
449
BMC LAN Interface IP Address Source
Name
bmcLANInterfaceIPAddressSource
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1.8
Description
Defines the source type of the IP address of the BMC LAN interface.
Syntax
DellBMCLANIPAddressSourceType
Access
Read-only
BMC LAN Interface IP Address
Name
bmcLANInterfaceIPAddress
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1.9
Description
Defines the IP address of the BMC LAN interface.
Syntax
IpAddress
Access
Read-only
BMC LAN Interface Subnet Mask Address
Name
bmcLANInterfaceSubnetMaskAddress
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1.10
Description
Defines the subnet mask of the BMC LAN interface.
Syntax
IpAddress
Access
Read-only
BMC LAN Interface Default Gateway Address
450
Name
bmcLANInterfaceDefaultGatewayAddress
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1.11
Description
Defines the IP address of the default gateway for the BMC LAN interface.
Syntax
IpAddress
Access
Read-only
Baseboard Management Controller Group
BMC LAN Interface MAC Address
Name
bmcLANInterfaceMACAddress
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1.12
Description
Defines the MAC address of the BMC LAN interface.
Syntax
DellMACAddress
Access
Read-only
BMC LAN Interface Alert Community Name
Name
bmcLANInterfaceAlertCommunityName
Object ID
1.3.6.1.4.1.674.10892.1.1900.30.1.13
Description
Defines the SNMP community used for BMC LAN alerts (traps)
sent on the BMC LAN interface.
Syntax
DisplayString (SIZE (0..32))
Access
Read-only
Baseboard Management Controller Group Variable Values
This section includes definitions for server administrator-specific variable values used in this section.
Table 21-1.
BMC Serial Connection Mode Capabilities
Variable Name: DellBMCSerialConnectionModeCapabilities
Data Type: Integer
These values are bit masks; therefore, combination values are possible.
Possible Data Values
Meaning of Data Value
-- none(0)
No mode capabilities.
modemBasic(1)
BMC serial interface supports Modem Basic mode.
modemPPP(2)
BMC serial interface supports Modem Point to Point
Protocol (PPP) mode.
modemTerminal(4)
BMC serial interface supports Modem Terminal mode.
directBasic(8)
BMC serial interface supports Direct Basic mode.
directPPP(16)
BMC serial interface supports Direct PPP mode.
directTerminal(32)
BMC serial interface supports Direct Terminal mode.
Baseboard Management Controller Group
451
Table 21-2.
BMC Serial Connection Mode Settings
Variable Name: DellBMCSerialConnectionModeSettings
Data Type: Integer
These values are bit masks; therefore, combination values are possible.
Possible Data Values
Meaning of Data Value
-- none(0)
No modes enabled.
modemBasic(1)
Modem Basic mode is enabled.
modemPPP(2)
Modem PPP mode is enabled.
modemTerminal(4)
Modem Terminal mode is enabled.
directBasic(8)
Direct Basic mode is enabled.
directPPP(16)
Direct PPP mode is enabled.
directTerminal(32)
Direct Terminal mode is enabled.
Table 21-3.
BMC Serial Flow Control Type
Variable Name: DellBMCSerialFlowControlType
Data Type: Integer
Possible Data Values
Meaning of Data Value
-- none(0)
No flow control used.
rtscts(1)
RTS/CTS (hardware) flow control used.
xonXoff(2)
XON/XOFF flow control used.
Table 21-4.
BMC Serial Bit Rate Type
Variable Name: DellBMCSerialBitRateType
Data Type: Integer
452
Possible Data Values
Meaning of Data Value
bps9600(6)
Bit rate is 9600 bps (bits per second)
bps19200(7)
Bit rate is 19200 bps
bps38400(8)
Bit rate is 38400 bps
bps57600(9)
Bit rate is 57600 bps
bps115200(10)
Bit rate is 115200 bps
Baseboard Management Controller Group
Table 21-5.
BMC LAN IP Address Source Type
Variable Name: DellBMCLANIPAddressSourceType
Data Type: Integer
Possible Data Values
Meaning of Data Value
-- unspecified(0)
Source is unspecified.
static(1)
IP address is static.
dhcp(2)
Dynamic Host Configuration Protocol (DHCP)
used to obtain IP address.
biosOrSystemSoftware(3)
BIOS or system software provided IP Address.
other(4)
Other protocol used to obtain IP address.
Baseboard Management Controller Group
453
454
Baseboard Management Controller Group
Field Replaceable Unit Group
A field replaceable unit (FRU) is a part that can be removed and replaced without having to send the
system to a repair facility. The Field Replaceable Unit Group provides information about the field
replaceable units that may be present in your system.
Field Replaceable Unit Group Tables
The objects in the FRU group define information such as manufacturer, serial number, part number
and revision for field replaceable units.The following MIB tables define the FRU group.
Field Replaceable Unit Table
Name
fruTable
Object ID
1.3.6.1.4.1.674.10892.1.2000.10
Description
Defines the Field Replaceable Unit table.
Syntax
SEQUENCE OF FruTableEntry
Access
Not accessible
FRU Table Entry
Name
fruTableEntry
Object ID
1.3.6.1.4.1.674.10892.1.2000.10.1
Description
Defines the FRU Table Entry.
Syntax
FruTableEntry
Access
Not accessible
Index
fruChassisIndex, fruIndex
Field Replaceable Unit Group
455
FRU Chassis Index
Name
fruChassisIndex
Object ID
1.3.6.1.4.1.674.10892.1.2000.10.1.1
Description
Defines the index (one-based) of the chassis containing the FRU.
Syntax
DellObjectRange
Access
Read-only
FRU Index
Name
fruIndex
Object ID
1.3.6.1.4.1.674.10892.1.2000.10.1.2
Description
Defines the index (one-based) of the FRU.
Syntax
DellObjectRange
Access
Read-only
FRU Information Status
456
Name
fruInformationStatus
Object ID
1.3.6.1.4.1.674.10892.1.2000.10.1.3
Description
Defines the status of the FRU table entry.
Syntax
DellStatus
Access
Read-only
Field Replaceable Unit Group
FRU Information State
Name
fruInformationState
Object ID
1.3.6.1.4.1.674.10892.1.2000.10.1.4
Description
Defines the state of the FRU information. Some information for the
FRU may not be available if the state is other than ok(1).
Syntax
DellFRUInformationState
Access
Read-only
FRU Device Name
Name
fruDeviceName
Object ID
1.3.6.1.4.1.674.10892.1.2000.10.1.5
Description
Defines the device name of the FRU.
Syntax
DisplayString (SIZE (0..64))
Access
Read-only
FRU Manufacturer Name
Name
fruManufacturerName
Object ID
1.3.6.1.4.1.674.10892.1.2000.10.1.6
Description
Defines the manufacturer of the FRU.
Syntax
DisplayString (SIZE (0..64))
Access
Read-only
FRU Serial Number Name
Name
fruSerialNumberName
Object ID
1.3.6.1.4.1.674.10892.1.2000.10.1.7
Description
Defines the serial number of the FRU.
Syntax
DisplayString (SIZE (0..64))
Access
Read-only
Field Replaceable Unit Group
457
FRU Part Number Name
Name
fruPartNumberName
Object ID
1.3.6.1.4.1.674.10892.1.2000.10.1.8
Description
Defines the part number of the FRU
Syntax
DisplayString (SIZE (0..64))
Access
Read-only
FRU Revision Name
Name
fruRevisionName
Object ID
1.3.6.1.4.1.674.10892.1.2000.10.1.9
Description
Defines the revision of the FRU.
Syntax
DisplayString (SIZE (0..64))
Access
Read-only
FRU Manufacturing Date Name
Name
fruManufacturingDateName
Object ID
1.3.6.1.4.1.674.10892.1.2000.10.1.10
Description
Defines the manufacturing date of the FRU.
Syntax
DellDateName
Access
Read-only
FRU Asset Tag Name
458
Name
fruAssetTagName
Object ID
1.3.6.1.4.1.674.10892.1.2000.10.1.11
Description
Defines the asset tag of the FRU.
Syntax
DisplayString (SIZE (0..64))
Access
Read-only
Field Replaceable Unit Group
FRU Group Variable Values
This section includes definitions for server administrator-specific variable values.
Table 22-1. FRU Information State
Variable Name: DellFRUInformationState
Data Type: Integer
Possible Data Values
Meaning of Data Value
ok(1)
FRU information is OK.
notSupported(2)
FRU information is not supported.
notAvailable(3)
FRU information is not available.
checksumInvalid(4)
FRU information checksum is invalid.
corrupted(5)
FRU information is corrupted.
Field Replaceable Unit Group
459
460
Field Replaceable Unit Group
Storage Management Group
The Storage Management Group is composed of the following:
•
Storage Management Group—information about the software product and system status.
•
Storage Management Information Group—properties about the Simple Network Management
Protocol (SNMP) agent.
•
Global Data Group—system status.
•
Physical Devices Group—physical devices managed by the software.
•
Logical Devices Group—logical devices managed by the software.
•
Storage Management Event Group—SNMP traps.
Storage Management Group
The Storage Management Information Base (MIB) Group defines the properties that identify
information about the Storage Management software product and the current status of the system
it manages.
Software Version
Name
softwareVersion
Object ID
1.3.6.1.4.1.674.10893.1.20.1
Description
Identifies the version number of the storage management component of the
systems management software.
Syntax
DisplayString
Access
Read-only
Storage Management Group
461
Global Status
Name
globalStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.2
Description
Identifies global health for the subsystem managed by the Storage Management
software. This global status is customized for HP OpenView. Other applications
should refer to the agentSystemGlobalStatus entry in the globalData object group.
Possible values:
1: Critical
2: Warning
3: Normal
4: Unknown
Syntax
Integer
Access
Read-only
Software Manufacturer
Name
softwareManufacturer
Object ID
1.3.6.1.4.1.674.10893.1.20.3
Description
Identifies the manufacturer of the Storage Management software.
Syntax
DisplayString
Access
Read-only
Software Product
Name
softwareProduct
Object ID
1.3.6.1.4.1.674.10893.1.20.4
Description
Identifies product information for the Storage Management software.
Syntax
DisplayString
Access
Read-only
Software Description
462
Name
softwareDescription
Object ID
1.3.6.1.4.1.674.10893.1.20.5
Description
Identifies the product description for the Storage Management software.
Syntax
DisplayString
Access
Read-only
Storage Management Group
Storage Management Information Group
The Storage Management Information MIB Group defines the properties that identify the
Storage Management software SNMP agent.
Display Name
Name
displayName
Object ID
1.3.6.1.4.1.674.10893.1.20.100.1
Description
Identifies the name of this management software for display purposes.
Syntax
DisplayString
Access
Read-only
Description
Name
description
Object ID
1.3.6.1.4.1.674.10893.1.20.100.2
Description
Provides a short description of this management software.
Syntax
DisplayString
Access
Read-only
Agent Vendor
Name
agentVendor
Object ID
1.3.6.1.4.1.674.10893.1.20.100.3
Description
Identifies the name of the management software manufacturer.
Syntax
DisplayString
Access
Read-only
Agent Version
Name
agentVersion
Object ID
1.3.6.1.4.1.674.10893.1.20.100.4
Description
This entry is obsolete. Refer to softwareVersion.
Syntax
DisplayString
Access
Read-only
Storage Management Group
463
Global Data Group
The Global Data Management Information Base (MIB) Group defines the properties that identify status
information about the system that the Storage Management software is managing and about the Storage
Management SNMP agent.
Agent System Global Status
Name
agentSystemGlobalStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.110.1
Description
This entry is obsolete. Use the value agentGlobalSystemStatus.
Syntax
Integer
Access
Read-only
Agent Last Global Status
Name
agentLastGlobalStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.110.2
Description
This entry is obsolete. Use the value agentLastGlobalSystemStatus.
Syntax
Integer
Access
Read-only
Agent Time Stamp
464
Name
agentTimeStamp
Object ID
1.3.6.1.4.1.674.10893.1.20.110.3
Description
Identifies the last time that the agent values have been updated. Universal time
in sec since UTC 1/1/70.
Syntax
Integer
Access
Read-only
Storage Management Group
Agent Get Timeout
Name
agentGetTimeout
Object ID
1.3.6.1.4.1.674.10893.1.20.110.4
Description
Indicates the suggested timeout value in milliseconds for how long the SNMP
getter should wait while attempting to poll the SNMP agent.
Syntax
Integer
Access
Read-only
Agent Modifiers
Name
agentModifiers
Object ID
1.3.6.1.4.1.674.10893.1.20.110.5
Description
Identifies the agent functional modifiers. When set, the modifier is active.
Bit definitions:
Bit 3: agent in debug mode.
All other bits are product specific.
Syntax
Integer
Access
Read-only
Agent Refresh Rate
Name
agentRefreshRate
Object ID
1.3.6.1.4.1.674.10893.1.20.110.6
Description
Identifies the rate, given in seconds, at which the cached data for SNMP is
refreshed. The default value is 300 seconds, or 5 minutes.
Syntax
Integer
Access
Read-only
Agent Hostname
Name
agentHostname
Object ID
1.3.6.1.4.1.674.10893.1.20.110.7
Description
This entry is obsolete for Storage Management.
Syntax
DisplayString
Access
Read-only
Storage Management Group
465
Agent IP Address
Name
agentIPAddress
Object ID
1.3.6.1.4.1.674.10893.1.20.110.8
Description
This entry is obsolete for Storage Management.
Syntax
DisplayString
Access
Read-only
Agent Software Status
Name
agentSoftwareStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.110.9
Description
This entry is obsolete for Storage Management.
Syntax
DisplayString
Access
Read-only
Agent SNMP Version
Name
agentSnmpVersion
Object ID
1.3.6.1.4.1.674.10893.1.20.110.10
Description
This entry is obsolete. Refer to 0001 softwareVersion.
Syntax
DisplayString
Access
Read-only
Agent MIB Version
466
Name
agentMibVersion
Object ID
1.3.6.1.4.1.674.10893.1.20.110.11
Description
Identifies the version of the Storage Management MIB.
Syntax
DisplayString
Access
Read-only
Storage Management Group
Agent Management Software URL Name
Name
agentManagementSoftwareURLName
Object ID
1.3.6.1.4.1.674.10893.1.20.110.12
Description
Identifies the Universal Resource Locator (URL) of the systems
management software.
Syntax
DisplayString
Access
Read-only
Agent Global System Status
Name
agentGlobalSystemStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.110.13
Description
Global health information for the subsystem managed by the Storage
Management software. This global status should be used by applications other
than HP OpenView. HP OpenView should refer to the globalStatus in the root
level object group. This is a rollup for the entire agent including any monitored
devices. The status is intended to give initiative to an SNMP monitor to get
further data when this status is abnormal. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax
DellStatus
Access
Read-only
Storage Management Group
467
Agent Last Global System Status
Name
agentLastGlobalSystemStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.110.14
Description
The previous global status of the system managed by the Storage Management
software. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax
DellStatus
Access
Read-only
Agent Smart Thermal Shutdown
Name
agentSmartThermalShutdown
Object ID
1.3.6.1.4.1.674.10893.1.20.110.15
Description
Indicates the status of smart thermal shutdown for PV220S and PV221S
enclosures.
Possible values:
1: Enabled
2: Disabled
3: Not applicable
468
Syntax
Integer
Access
Read-only
Storage Management Group
Physical Devices Group
The Physical Devices MIB group provides information about the devices managed by the Storage
Management software and their relationships to each other. The following MIB tables define objects and
relationships (connections) among the objects.
•
Controller Table—describes available properties for each controller on the managed system.
•
Channel Table—describes available properties for each channel on the managed system.
•
Enclosure Table—describes available properties for each enclosure on the managed system.
•
Array Disk Table—describes available properties for each physical array disk on the managed system.
•
Array Disk Enclosure Connection Table—describes the connections between Fibre Channel array
disks, their enclosure, and their associated controller. For each object in the table, its object "number"
corresponds to an instance number in the appropriate MIB table for that object where all of the object
properties can be found.
•
Array Disk Channel Connection Table—describes the connections between SCSI array disks, their
channel, and their associated controller. For each object in the table, its object "number" corresponds
to an instance number in the appropriate MIB table for that object where all of the object properties
can be found.
•
Fan Table—describes available properties for each fan on the managed system.
•
Fan Connection Table—describes the connection between each fan on the managed system and its enclosure.
Each enclosure "number" in the table corresponds to that enclosure instance in the Enclosure Table.
•
Power Supply Table—describes available properties for each power supply on the managed system.
•
Power Supply Connection Table—describes the connection between each power supply on the
managed system and its enclosure. Each enclosure "number" in the table corresponds to that enclosure
instance in the Enclosure Table.
•
Temperature Probe Table—describes available properties for each temperature probe on the
managed system.
•
Temperature Probe Connection Table—describes the connection between each temperature probe on
the managed system and its enclosure. Each enclosure "number" in the table corresponds to that
enclosure instance in the Enclosure Table.
•
EMM Table—describes available properties for each Enclosure Management Module (EMM) on the
managed system.
•
EMM Connection Table—describes the connection between each EMM on the managed system and
its enclosure. Each enclosure "number" in the table corresponds to that enclosure instance in the
Enclosure Table.
•
Battery Table—describes available properties for each controller battery on the managed system.
•
Battery Connection Table—describes the connection between each battery on the managed system
and its controller. Each controller "number" in the table corresponds to that controller instance in the
Controller Table.
Storage Management Group
469
Controller Table
This table describes available properties for each controller on the managed system.
The following object sets up the Controller Table.
Name
controllerTable
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1
Description
Defines the controller table, which is a table of managed Redundant Array of
Independent disks (RAID) controllers. The number of entries is related to the
number of RAID controllers discovered in the system.
Syntax
SEQUENCE OF ControllerEntry
Access
Not accessible
Controller Entry
Name
controllerEntry
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1
Description
Defines the controller table entry, which is an entry in the table of RAID
controllers. A row in this table cannot be created or deleted by SNMP operations
on columns of the table.
Syntax
ControllerEntry
Access
Not accessible
Index
controllerNumber
Controller Number
470
Name
controllerNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.1
Description
Identifies the instance number of the controller entry.
Syntax
Integer
Access
Read-only
Storage Management Group
Controller Name
Name
controllerName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.2
Description
Identifies the name of the controller in this subsystem as represented in Storage
Management. Includes the controller type and instance. For example:
PERC 3/QC 1.
Syntax
DisplayString
Access
Read-only
Controller Vendor
Name
controllerVendor
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.3
Description
Identifies the controller's (re)seller's name.
Syntax
DisplayString
Access
Read-only
Controller Type
Name
controllerType
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.4
Description
Identifies the type of this controller:
1: SCSI
2: PV660F
3: PV662F
4: Integrated/Intelligent Drive Electronics (IDE)
5: Serial Advanced Technology Architecture (SATA)
6: Serial Attached SCSI (SAS)
Syntax
Integer
Access
Read-only
Storage Management Group
471
Controller State
Name
controllerState
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.5
Description
Identifies the status of the controller's subsystem (which includes any devices
connected to it). Possible states:
0: Unknown
1: Ready
2: Failed
3: Online
4: Offline
6: Degraded
Syntax
Integer
Access
Read-only
Controller Severity
Name
controllerSeverity
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.6
Description
This entry is obsolete for Storage Management. It was replaced with
RollUpStatus and ComponentStatus for each device.
Syntax
Integer
Access
Read-only
Controller Rebuild Rate in Percent
472
Name
controllerRebuildRateInPercent
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.7
Description
Identifies the percent of the compute cycles dedicated to rebuilding failed
array disks.
Syntax
Integer
Access
Read-only
Storage Management Group
Controller Firmware Version
Name
controllerFWVersion
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.8
Description
Identifies the controller's current firmware version.
Syntax
DisplayString
Access
Read-only
Controller Cache Size in Megabytes
Name
controllerCacheSizeInMB
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.9
Description
Identifies the controller's current amount of cache memory in megabytes. If this
size is 0, it is less than a megabyte.
Syntax
Integer
Access
Read-only
Controller Cache Size in Bytes
Name
controllerCacheSizeInBytes
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.10
Description
Identifies the controller's current amount of cache memory that is less than a
megabyte. This combined with the controllerCacheSizeInMB will be the total
amount of memory.
Syntax
Integer
Access
Read-only
Controller Physical Device Count
Name
controllerPhysicalDeviceCount
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.11
Description
Identifies the number of physical devices on the controller channel including
both disks and the controller.
Syntax
Integer
Access
Read-only
Storage Management Group
473
Controller Logical Device Count
Name
controllerLogicalDeviceCount
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.12
Description
Identifies the number of virtual disks on the controller.
Syntax
Integer
Access
Read-only
Controller Partner Status
Name
controllerPartnerStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.13
Description
This entry is obsolete for Storage Management.
Syntax
DisplayString
Access
Read-only
Controller Host Port Count
Name
controllerHostPortCount
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.14
Description
This entry is obsolete. Fibre channel is not supported in Storage Management.
Syntax
Integer
Access
Read-only
Controller Memory Size in Megabytes
474
Name
controllerMemorySizeInMB
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.15
Description
Identifies the size of memory in megabytes on the controller. If this size is 0, it is
less than a megabyte. This attribute is only supported on Adaptec controllers.
Syntax
Integer
Access
Read-only
Storage Management Group
Controller Memory Size in Bytes
Name
controllerMemorySizeInBytes
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.16
Description
Identifies the size of memory on the controller that is less than a megabyte.
This combined with the controllerMemorySizeInMB will be the total size of
the memory. This attribute is only supported on Adaptec controllers.
Syntax
Integer
Access
Read-only
Controller Drive Channel Count
Name
controllerDriveChannelCount
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.17
Description
This entry is obsolete. Fibre channel is not supported in Storage Management.
Syntax
Integer
Access
Read-only
Controller Fault Tolerant
Name
controllerFaultTolerant
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.18
Description
This entry is obsolete. Fibre channel is not supported in Storage Management.
Syntax
Integer
Access
Read-only
Controller C0 Port 0 World Wide Name
Name
controllerC0Port0WWN
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.19
Description
This entry is obsolete. Fibre channel is not supported in Storage Management.
Syntax
DisplayString
Access
Read-only
Storage Management Group
475
Controller C0 Port 0 Name
Name
controllerC0Port0Name
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.20
Description
This entry is obsolete. Fibre channel is not supported in Storage Management.
Syntax
DisplayString
Access
Read-only
Controller C0 Port 0 ID
Name
controllerC0Port0ID
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.21
Description
This entry is obsolete. Fibre channel is not supported in Storage Management.
Syntax
Integer
Access
Read-only
Controller C0 Target
Name
controllerC0Target
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.22
Description
This entry is obsolete. Fibre channel is not supported in Storage Management.
Syntax
Integer
Access
Read-only
Controller C0 Channel
476
Name
controllerC0Channel
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.23
Description
This entry is obsolete. Fibre channel is not supported in Storage Management.
Syntax
Integer
Access
Read-only
Storage Management Group
Controller C0 Operating System Controller
Name
controllerC0OSController
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.24
Description
This entry is obsolete. Fibre channel is not supported in Storage Management.
Syntax
DisplayString
Access
Read-only
Controller C0 Battery State
Name
controllerC0BatteryState
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.25
Description
This entry is obsolete. Fibre channel is not supported in Storage Management.
Syntax
Integer
Access
Read-only
Controller C1 Port 0 World Wide Name
Name
controllerC1Port0WWN
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.26
Description
This entry is obsolete. Fibre channel is not supported in Storage Management.
Syntax
DisplayString
Access
Read-only
Controller C1 Port 0 Name
Name
controllerC1Port0Name
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.27
Description
This entry is obsolete. Fibre channel is not supported in Storage Management.
Syntax
DisplayString
Access
Read-only
Storage Management Group
477
Controller C1 Port 0 ID
Name
controllerC1Port0ID
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.28
Description
This entry is obsolete. Fibre channel is not supported in Storage Management.
Syntax
Integer
Access
Read-only
Controller C1 Target
Name
controllerC1Target
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.29
Description
This entry is obsolete. Fibre channel is not supported in Storage Management.
Syntax
Integer
Access
Read-only
Controller C1 Channel
Name
controllerC1Channel
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.30
Description
This entry is obsolete. Fibre channel is not supported in Storage Management.
Syntax
Integer
Access
Read-only
Controller C1 Operating System Controller
478
Name
controllerC1OSController
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.31
Description
This entry is obsolete. Fibre channel is not supported in Storage Management.
Syntax
DisplayString
Access
Read-only
Storage Management Group
Controller Battery State C1
Name
controllerC1BatteryState
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.32
Description
This entry is obsolete. Fibre channel is not supported in Storage Management.
Syntax
Integer
Access
Read-only
Controller Node World Wide Name
Name
controllerNodeWWN
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.33
Description
This entry is obsolete. Fibre channel is not supported in Storage Management.
Syntax
DisplayString
Access
Read-only
Controller C0 Port 1 World Wide Name
Name
controllerC0Port1WWN
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.34
Description
This entry is obsolete. Fibre channel is not supported in Storage Management.
Syntax
DisplayString
Access
Read-only
Controller C1 Port 1 World Wide Name
Name
controllerC1Port1WWN
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.35
Description
This entry is obsolete. Fibre channel is not supported in Storage Management.
Syntax
DisplayString
Access
Read-only
Storage Management Group
479
Controller Battery Charge Count
Name
controllerBatteryChargeCount
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.36
Description
This entry is obsolete. Fibre channel is not supported in Storage Management.
Syntax
Integer
Access
Read-only
Controller Roll-Up Status
Name
controllerRollUpStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.37
Description
Indicates severity of the controller state. This is the combined status of the
controller and its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax
DellStatus
Access
Read-only
Controller Component Status
Name
controllerComponentStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.38
Description
Indicates the status of the controller itself without the propagation of any
contained component status. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
480
Syntax
DellStatus
Access
Read-only
Storage Management Group
Controller Nexus ID
Name
controllerNexusID
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.39
Description
Durable unique ID for this controller.
Syntax
DisplayString
Access
Read-only
Controller Alarm State
Name
controllerAlarmState
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.40
Description
Indicates state, or setting for the controller's alarm. Possible values:
1: Enabled
2: Disabled
3: Not Applicable
Syntax
Integer
Access
Read-only
Controller Driver Version
Name
controllerDriverVersion
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.41
Description
Indicates currently installed driver version of the controller
Syntax
DisplayString
Access
Read-only
Controller PCI Slot
Name
controllerPCISlot
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.42
Description
Indicates the PCI slot number or embedded number for controllers on the
motherboard
Syntax
DisplayString
Access
Read-only
Storage Management Group
481
Controller Cluster Mode
Name
controllerClusterMode
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.43
Description
Identifies if the controller is in cluster mode.
Possible values:
1: Enabled
2: Disabled
3: Active (enabled and active)
99: Not Applicable
Syntax
Integer
Access
Read-only
Controller Minimum Firmware Version
Name
controllerMinFWVersion
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.44
Description
The minimum firmware version for Storage Management to support the controller.
Syntax
DisplayString
Access
Read-only
Controller Minimum Driver Version
Name
controllerMinDriverVersion
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.45
Description
The minimum driver version for Storage Management to support the controller.
Syntax
DisplayString
Access
Read-write
Controller SCSI Initiator ID
482
Name
controllerSCSIInitiatorID
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.46
Description
The SCSI ID of the initiator.
Syntax
Integer
Access
Read-only
Storage Management Group
Controller Channel Count
Name
controllerChannelCount
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.47
Description
The number of channels on the controller.
Syntax
Integer
Access
Read-only
Controller Reconstruct Rate
Name
controllerReconstructRate
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.48
Description
The rate for reconstruct on the controller.
Syntax
Integer
Access
Read-write
Controller Patrol Read Rate
Name
controllerPatrolReadRate
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.49
Description
The rate for patrol read on the controller.
Syntax
Integer
Access
Read-only
Controller BGI Rate
Name
controllerBGIRate
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.50
Description
The rate for background initialization on the controller.
Syntax
Integer
Access
Read-only
Storage Management Group
483
Controller Check Consistency Rate
Name
controllerCheckConsistencyRate
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.51
Description
The rate for check consistency on the controller.
Syntax
Integer
Access
Read-only
Controller Patrol Read Mode
Name
controllerPatrolReadMode
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.52
Description
Identifies the patrol read mode.
Possible values:
1: Automatic (enabled)
2: Manual (enabled)
3: Disabled
Syntax
Integer
Access
Read-only
Controller Patrol Read State
Name
controllerPatrolReadState
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.53
Description
The state of the patrol read.
Possible values:
1: Stopped - not running
2: Ready - ready to start
4: Active - is running
8: Aborted - has aborted
484
Syntax
Integer
Access
Read-only
Storage Management Group
Controller Patrol Read Iterations
Name
controllerPatrolReadIterations
Object ID
1.3.6.1.4.1.674.10893.1.20.130.1.1.54
Description
The number of times Patrol Read has been run on this controller.
Syntax
Integer
Access
Read-only
Channel Table
This table describes available properties for each channel on the managed system.
The following object sets up the Channel Table.
Name
channelTable
Object ID
1.3.6.1.4.1.674.10893.1.20.130.2
Description
Defines the channel table.
Syntax
SEQUENCE OF ChannelEntry
Access
Not accessible
Channel Entry
Name
channelEntry
Object ID
1.3.6.1.4.1.674.10893.1.20.130.2.1
Description
Defines the channel table entry.
Syntax
ChannelEntry
Access
Not accessible
Index:
channelNumber
Channel Number
Name
channelNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.2.1.1
Description
Identifies the instance number of the channel entry.
Syntax
Integer
Access
Read-only
Storage Management Group
485
Channel Name
Name
channelName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.2.1.2
Description
Identifies the name of the channel as represented in Storage Management.
The name will include the word channel and the instance.
For example: Channel 1.
Syntax
DisplayString
Access
Read-only
Channel State
Name
channelState
Object ID
1.3.6.1.4.1.674.10893.1.20.130.2.1.3
Description
Identifies the current state of this channel. Possible states:
0: Unknown
1: Ready - The I/O has resumed.
2: Failed
3: Online
4: Offline - The I/O has paused.
6: Degraded
Syntax
Integer
Access
Read-only
Channel Severity
486
Name
channelSeverity
Object ID
1.3.6.1.4.1.674.10893.1.20.130.2.1.4
Description
This entry is obsolete for Storage Management. It was replaced with
RollUpStatus and ComponentStatus for each device.
Syntax
Integer
Access
Read-only
Storage Management Group
Channel Termination
Name
channelTermination
Object ID
1.3.6.1.4.1.674.10893.1.20.130.2.1.5
Description
Identifies the type of SCSI termination on this channel. Termination is required
for proper operation of this channel. Possible values:
1: Wide Termination (16 bit)
2: Narrow Termination (8 bit)
3: Not Terminated
Syntax
Integer
Access
Read-only
Channel SCSI ID
Name
channelSCSIID
Object ID
1.3.6.1.4.1.674.10893.1.20.130.2.1.6
Description
Identifies the SCSI ID of the controller to which the channel belongs.
Syntax
Integer
Access
Read-only
Channel Roll-Up Status
Name
channelRollUpStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.130.2.1.7
Description
Identifies the severity of the channel state. This is the combined status of the
channel and its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax
DellStatus
Access
Read-only
Storage Management Group
487
Channel Component Status
Name
channelComponentStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.130.2.1.8
Description
The status of the channel itself without the propagation of any contained
component status. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax
DellStatus
Access
Read-only
Channel Nexus ID
Name
channelNexusID
Object ID
1.3.6.1.4.1.674.10893.1.20.130.2.1.9
Description
Durable unique ID for this channel.
Syntax
DisplayString
Access
Read-only
Channel Data Rate
488
Name
channelDataRate
Object ID
1.3.6.1.4.1.674.10893.1.20.130.2.1.10
Description
Identifies the data rate of this channel.
Syntax
DisplayString
Access
Read-only
Storage Management Group
Channel Bus Type
Name
channelBusType
Object ID
1.3.6.1.4.1.674.10893.1.20.130.2.1.11
Description
The bus type of the channel. Possible values:
1: SCSI
2: IDE
3: Fibre Channel
4: Serial Storage Architecture (SSA)
6: Universal Serial Bus (USB)
7: SATA
8: SAS
Syntax
Integer
Access
Read-only
Enclosure Table
This table describes available properties for each enclosure on the managed system.
The following object sets up the Enclosure Table.
Name
enclosureTable
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3
Description
Defines the enclosure table.
Syntax
SEQUENCE OF EnclosureEntry
Access
Not accessible
Enclosure Entry
Name
enclosureEntry
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1
Description
Defines the enclosure table entry.
Syntax
EnclosureEntry
Access
Not accessible
Index
enclosureNumber
Storage Management Group
489
Enclosure Number
Name
enclosureNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.1
Description
Identifies the instance number of the enclosure entry.
Syntax
Integer
Access
Read-only
Enclosure Name
Name
enclosureName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.2
Description
Identifies the enclosure's name as represented in Storage Management.
Syntax
DisplayString
Access
Read-only
Enclosure Vendor
Name
enclosureVendor
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.3
Description
Identifies the enclosure's (re)seller's name.
Syntax
DisplayString
Access
Read-only
Enclosure State
Name
enclosureState
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.4
Description
The current condition of the enclosure (which includes any devices connected to it.)
Possible values:
0: Unknown
1: Ready
2: Failed
3: Online
4: Offline
6: Degraded
490
Syntax
Integer
Access
Read-only
Storage Management Group
Enclosure Severity
Name
enclosureSeverity
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.5
Description
This entry is obsolete for Storage Management. It was replaced with
RollUpStatus and ComponentStatus for each device.
Syntax
Integer
Access
Read-only
Enclosure ID
Name
enclosureID
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.6
Description
Identifies the SCSI address of the processor.
Syntax
Integer
Access
Read-only
Enclosure Processor Version
Name
enclosureProcessorVersion
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.7
Description
This entry is obsolete for Storage Management.
Syntax
DisplayString
Access
Read-only
Enclosure Service Tag
Name
enclosureServiceTag
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.8
Description
The enclosure identification used when consulting customer support.
Syntax
DisplayString
Access
Read-only
Storage Management Group
491
Enclosure Asset Tag
Name
enclosureAssetTag
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.9
Description
Customer definable asset tag for the enclosure.
Syntax
DisplayString
Access
Read-only
Enclosure Asset Name
Name
enclosureAssetName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.10
Description
Customer definable asset name of the enclosure.
Syntax
DisplayString
Access
Read-only
Enclosure Split Bus Part Number
Name
enclosureSplitBusPartNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.11
Description
Identifies the enclosure's split bus part number.
Syntax
DisplayString
Access
Read-only
Enclosure Product ID
492
Name
enclosureProductID
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.12
Description
Identifies the enclosure's product identification. This also corresponds to the
enclosure type.
Syntax
DisplayString
Access
Read-only
Storage Management Group
Enclosure Kernel Version
Name
enclosureKernelVersion
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.13
Description
This entry is obsolete for Storage Management.
Syntax
DisplayString
Access
Read-only
Enclosure ESM1 Part Number
Name
enclosureESM1PartNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.14
Description
This entry is obsolete for Storage Management.
Syntax
DisplayString
Access
Read-only
Enclosure ESM2 Part Number
Name
enclosureESM2PartNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.15
Description
This entry is obsolete for Storage Management.
Syntax
DisplayString
Access
Read-only
Storage Management Group
493
Enclosure Type
Name
enclosureType
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.16
Description
Indicates the type of the enclosure. Possible values:
1: Internal
2: Dell™ PowerVault™ 200S (PV201S)
3: Dell PV210S (PV211S)
4: Dell PV220S (PV221S)
5: Dell PV660F
6: Dell PV224F
7: Dell PV660F/PV224F
8: Dell MD1000
Syntax
DisplayString
Access
Read-only
Enclosure Processor2 Version
Name
enclosureProcessor2Version
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.17
Description
This entry is obsolete for Storage Management.
Syntax
DisplayString
Access
Read-only
Enclosure Configuration
Name
enclosureConfig
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.18
Description
Identifies the current configuration of the enclosure's backplane. Possible values:
1: Joined
2: Split Bus
3: Clustered
4: Unified
494
Syntax
Integer
Access
Read-only
Storage Management Group
Enclosure Channel Number
Name
enclosureChannelNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.19
Description
Identifies the channel number, or bus, to which the enclosure is connected.
Syntax
Integer
Access
Read-only
Enclosure Alarm
Name
enclosureAlarm
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.20
Description
Identifies the current status of the enclosure's alarm (PV220S and PV221S only.)
Possible values:
1: Disabled
2: Enabled
Syntax
Integer
Access
Read-only
Enclosure Backplane Part Number
Name
enclosureBackplanePartNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.21
Description
Identifies the part number of the enclosure's backplane.
Syntax
Integer
Access
Read-only
Enclosure SCSI ID
Name
enclosureSCSIID
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.22
Description
Identifies the SCSI ID of the controller to which this enclosure is attached.
Syntax
Integer
Access
Read-only
Storage Management Group
495
Enclosure Roll-Up Status
Name
enclosureRollUpStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.23
Description
Identifies the severity of the enclosure state. This is the combined status of the
enclosure and its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax
DellStatus
Access
Read-only
Enclosure Component Status
Name
enclosureComponentStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.24
Description
The status of the enclosure itself without the propagation of any contained
component status. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax
DellStatus
Access
Read-only
Enclosure Nexus ID
496
Name
enclosureNexusID
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.25
Description
Durable unique ID for this enclosure.
Syntax
Integer
Access
Read-only
Storage Management Group
Enclosure FirmWare Version
Name
enclosureFirmwareVersion
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.26
Description
The firmware version of the enclosure.
Syntax
DisplayString
Access
Read-only
Enclosure SCSI Rate
Name
enclosureSCSIRate
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.27
Description
Actual SCSI rate in the enclosure.
Syntax
DisplayString
Access
Read-only
Enclosure Part Number
Name
enclosurePartNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.28
Description
The part number of the enclosure.
Syntax
DisplayString
Access
Read-only
Enclosure Serial Number
Name
enclosureSerialNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.29
Description
Serial number of the enclosure.
Syntax
DisplayString
Access
Read-only
Enclosure SAS Address
Name
enclosureSASAddress
Object ID
1.3.6.1.4.1.674.10893.1.20.130.3.1.30
Description
The specified SAS address if this is a SAS enclosure.
Syntax
DisplayString
Access
Read-only
Storage Management Group
497
Array Disk Table
This table describes available properties for each physical array disk on the managed system.
The following object sets up the Array Disk Table.
Name
arrayDiskTable
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4
Description
Defines the array disk table.
Syntax
SEQUENCE OF ArrayDiskEntry
Access
Not accessible
Array Disk Entry
Name
arrayDiskEntry
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1
Description
Defines the array disk table entry.
Syntax
ArrayDiskEntry
Access
Not accessible
Index
arrayDiskNumber
Array Disk Number
Name
arrayDiskNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.1
Description
Identifies the instance number of the array disk entry.
Syntax
Integer
Access
Read-only
Array Disk Name
498
Name
arrayDiskName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.2
Description
Identifies the name of the array disk as represented in Storage Management.
Syntax
DisplayString
Access
Read-only
Storage Management Group
Array Disk Vendor
Name
arrayDiskVendor
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.3
Description
The array disk's manufacturer's name.
Syntax
DisplayString
Access
Read-only
Array Disk State
Name
arrayDiskState
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.4
Description
Identifies the current state of the array disk. Possible states:
0: Unknown
1: Ready - Available for use, but no RAID configuration has been assigned.
2: Failed - Not operational.
3: Online - Operational. RAID configuration has been assigned.
4: Offline - The drive is not available to the RAID controller.
6: Degraded - Refers to a fault-tolerant array/virtual disk that has a failed disk.
7: Recovering - Refers to state of recovering from bad blocks on disks.
11: Removed - Indicates that array disk has been removed.
15: Resynching - Indicates one of the following types of disk operations:
Transform Type, Reconfiguration, and Check Consistency.
24: Rebuild
25: No Media - CD-ROM or removable disk has no media.
26: Formatting - In the process of formatting.
28: Diagnostics - Diagnostics are running.
34: Predictive Failure
35: Initializing: Applies only to virtual disks on PowerEdge™ RAID Controller
(PERC), PERC 2/SC, and PERC 2/DC controllers.
39: Foreign
40: Clear
41: Unsupported
53: Incompatible
Syntax
Integer
Access
Read-only
Storage Management Group
499
Array Disk Severity
Name
arrayDiskSeverity
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.5
Description
This entry is obsolete for Storage Management. It was replaced with
RollUpStatus and ComponentStatus for each device.
Syntax
Integer
Access
Read-only
Array Disk Product ID
Name
arrayDiskProductID
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.6
Description
Identifies the model number of the array disk.
Syntax
DisplayString
Access
Read-only
Array Disk Serial Number
Name
arrayDiskSerialNo
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.7
Description
Identifies the array disk's unique identification number from the manufacturer.
Syntax
DisplayString
Access
Read-only
Array Disk Revision
500
Name
arrayDiskRevision
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.8
Description
Identifies the firmware version of the array disk.
Syntax
DisplayString
Access
Read-only
Storage Management Group
Array Disk Enclosure ID
Name
arrayDiskEnclosureID
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.9
Description
Identifies the SCSI ID of the enclosure processor to which this array disk belongs.
Syntax
DisplayString
Access
Read-only
Array Disk Channel
Name
arrayDiskChannel
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.10
Description
Identifies the bus to which this array disk is connected.
Syntax
Integer
Access
Read-only
Array Disk Length in Megabytes
Name
arrayDiskLengthInMB
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.11
Description
Identifies the size in megabytes of the array disk. If this size is 0, it is smaller than
a megabyte.
Syntax
Integer
Access
Read-only
Array Disk Length in Bytes
Name
arrayDiskLengthInBytes
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.12
Description
Identifies the size of the array disk in bytes that is less than a megabyte. This size
plus the arrayDiskLengthInMB is the total size of the array disk.
Syntax
Integer
Access
Read-only
Storage Management Group
501
Array Disk Largest Contiguous Free Space in Megabytes
Name
arrayDiskLargestContiguousFreeSpaceInMB
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.13
Description
The size in megabytes of the largest contiguous free space on the array disk.
If this size is 0, it is less than a megabyte.
Syntax
Integer
Access
Read-only
Array Disk Largest Contiguous Free Space in Bytes
Name
arrayDiskLargestContiguousFreeSpaceInBytes
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.14
Description
The size of the largest contiguous free space on this array disk in bytes that is less
than a megabyte.This size plus the arrayDiskLargestContiguousFreeSpaceInMB
is the total size of the largest contiguous free space on the array disk.
Syntax
Integer
Access
Read-only
Array Disk Target ID
Name
arrayDiskTargetID
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.15
Description
Identifies the SCSI target ID which this array disk is assigned.
Syntax
Integer
Access
Read-only
Array Disk LUN ID
502
Name
arrayDiskLunID
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.16
Description
Identifies the array disk's logical unit number.
Syntax
Integer
Access
Read-only
Storage Management Group
Array Disk Used Space in Megabytes
Name
arrayDiskUsedSpaceInMB
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.17
Description
Identifies the amount in megabytes of the used space on the array disk. If this
size is 0, it is smaller than a megabyte.
Syntax
Integer
Access
Read-only
Array Disk Used Space in Bytes
Name
arrayDiskUsedSpaceInBytes
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.18
Description
Identifies the size in bytes of the used space on the array disk that is smaller than
a megabyte. This size plus the arrayDiskUsedSpaceInMB is the total amount of
used space on the array disk.
Syntax
Integer
Access
Read-only
Array Disk Free Space in Megabytes
Name
arrayDiskFreeSpaceInMB
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.19
Description
Identifies the amount in megabytes of the free space on the array disk. If this size
is 0, it is smaller than a megabyte.
Syntax
Integer
Access
Read-only
Array Disk Free Space in Bytes
Name
arrayDiskFreeSpaceInBytes
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.20
Description
Identifies the size in bytes of the free space on the array disk that is smaller than a
megabyte. This size plus the arrayDiskFreeSpaceInMB is the total amount of
free space on the array disk.
Syntax
Integer
Access
Read-only
Storage Management Group
503
Array Disk Bus Type
Name
arrayDiskBusType
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.21
Description
Identifies the bus type of the array disk. Possible values:
1: SCSI
2: IDE
3: Fibre Channel
4: SSA
6: USB
7: SATA
8: SAS
Syntax
Integer
Access
Read-only
Array Disk Spare State
Name
arrayDiskSpareState
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.22
Description
Identifies the status of the array disk as a spare. Possible states:
1: Disk is a member of a virtual disk
2: Disk is a member of a disk group
3: Disk is a global hot spare
4: Disk is a dedicated hot spare
5: Not a spare
99: Not applicable
504
Syntax
Integer
Access
Read-only
Storage Management Group
Array Disk Roll-Up Status
Name
arrayDiskRollUpStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.23
Description
Severity of the array disk state. This is the combined status of the array disk and
its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax
DellStatus
Access
Read-only
Array Disk Component Status
Name
arrayDiskComponentStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.24
Description
The status of the array disk itself without the propagation of any contained
component status. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax
DellStatus
Access
Read-only
Array Disk Device Name
Name
arrayDiskDeviceName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.25
Description
Identifies the operating system device name for this disk.
Syntax
DisplayString
Access
Read-only
Storage Management Group
505
Array Disk Nexus ID
Name
arrayDiskNexusID
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.26
Description
Indicates the durable unique ID for this array disk.
Syntax
DisplayString
Access
Read-only
Array Disk Part Number
Name
arrayDiskPartNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.27
Description
Indicates the part number of the disk.
Syntax
DisplayString
Access
Read-only
Array Disk SAS Address
Name
arrayDiskSASAddress
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.28
Description
Indicates the specified SAS address if this is a SAS disk.
Syntax
DisplayString
Access
Read-only
Array Disk Negotiated Speed
506
Name
arrayDiskNegotiatedSpeed
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.29
Description
Indicates the speed at which the drive is actually running in MPS (megabytes per
second).
Syntax
Integer
Access
Read-only
Storage Management Group
Array Disk Capable Speed
Name
arrayDiskCapableSpeed
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.30
Description
Indicates the maximum speed at which the drive is capable of negotiating in
MPS (megabytes per second).
Syntax
Integer
Access
Read-only
Array Disk Smart Alert Indication
Name
arrayDiskSmartAlertIndication
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.31
Description
Indicates whether the disk has received a predictive failure.
Possible values:
1: No - disk has not received a predictive failure alert
2: Yes - disk has received a predictive failure alert
Syntax
Integer
Access
Read-only
Array Disk Manufacture Day
Name
arrayDiskManufactureDay
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.32
Description
Indicates the day of the week (1=Sunday through 7=Saturday) on which this
disk was manufactured.
Syntax
DisplayString
Access
Read-only
Array Disk Manufacture Week
Name
arrayDiskManufactureWeek
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.33
Description
The week (1 through 53) in which this disk was manufactured.
Syntax
DisplayString
Access
Read-only
Storage Management Group
507
Array Disk Manufacture Year
Name
arrayDiskManufactureYear
Object ID
1.3.6.1.4.1.674.10893.1.20.130.4.1.34
Description
The four digit year in which this disk was manufactured.
Syntax
DisplayString
Access
Read-only
Array Disk Enclosure Connection Table
This table describes the connections among array disks, their enclosure, and their associated controller.
For each object in the table, its object "number" corresponds to an instance number in the appropriate
MIB table for that object where all of the object properties can be found.
NOTE: Only array disks that are part of an enclosure will be listed in this table. Backplanes are considered
enclosures by Storage Management.
The following object sets up the Array Disk Enclosure Connection Table.
Name
arrayDiskEnclosureConnectionTable
Object ID
1.3.6.1.4.1.674.10893.1.20.130.5
Description
Defines the array disk enclosure connection table.
Syntax
SEQUENCE OF ArrayDiskEnclosureConnectionEntry
Access
Not accessible
Array Disk Enclosure Connection Entry
508
Name
arrayDiskEnclosureConnectionEntry
Object ID
1.3.6.1.4.1.674.10893.1.20.130.5.1
Description
Defines the array disk enclosure connection table entry.
Syntax
ArrayDiskEnclosureConnectionEntry
Access
Not accessible
Index
arrayDiskEnclosureConnectionNumber
Storage Management Group
Array Disk Enclosure Connection Number
Name
arrayDiskEnclosureConnectionNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.5.1.1
Description
Identifies the instance number of the array disk enclosure connection entry.
Syntax
Integer
Access
Read-only
Array Disk Enclosure Connection Array Disk Name
Name
arrayDiskEnclosureConnectionArrayDiskName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.5.1.2
Description
Identifies the name of the array disk in this connection as represented in
Storage Management.
Syntax
DisplayString
Access
Read-only
Array Disk Enclosure Connection Array Disk Number
Name
arrayDiskEnclosureConnectionArrayDiskNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.5.1.3
Description
Identifies the instance number of the array disk in the arrayDiskTable in this
connection.
Syntax
Integer
Access
Read-only
Array Disk Enclosure Connection Enclosure Name
Name
arrayDiskEnclosureConnectionEnclosureName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.5.1.4
Description
Identifies the name of the enclosure as represented in Storage Management to
which this array disk belongs.
Syntax
DisplayString
Access
Read-only
Storage Management Group
509
Array Disk Enclosure Connection Enclosure Number
Name
arrayDiskEnclosureConnectionEnclosureNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.5.1.5
Description
Identifies the instance number in the enclosureTable of the enclosure to which
this array disk belongs.
Syntax
Integer
Access
Read-only
Array Disk Enclosure Connection Controller Name
Name
arrayDiskEnclosureConnectionControllerName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.5.1.6
Description
Identifies the name of the controller as represented in Storage Management to
which this array disk is connected.
Syntax
DisplayString
Access
Read-only
Array Disk Enclosure Connection Controller Number
Name
arrayDiskEnclosureConnectionControllerNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.5.1.7
Description
Identifies the instance number in the controllerTable of the controller to which
this array disk is connected.
Syntax
Integer
Access
Read-only
Array Disk Channel Connection Table
This table describes the connections between array disks, their channel, and their associated controller.
For each object in the table, its object "number" corresponds to an instance number in the appropriate
MIB table for that object where all of the object properties can be found.
NOTE: Only array disks that are NOT part of an enclosure will be listed in this table. Backplanes are considered
enclosures by Storage Management.
510
Storage Management Group
The following object sets up the Array Disk Channel Connection Table.
Name
arrayDiskChannelConnectionTable
Object ID
1.3.6.1.4.1.674.10893.1.20.130.6
Description
Defines the array disk channel connection table.
Syntax
SEQUENCE OF ArrayDiskChannelConnectionEntry
Access
Not accessible
Array Disk Channel Connection Entry
Name
arrayDiskChannelConnectionEntry
Object ID
1.3.6.1.4.1.674.10893.1.20.130.6.1
Description
Defines the array disk channel connection table entry.
Syntax
ArrayDiskChannelConnectionEntry
Access
Not accessible
Index
arrayDiskEnclosureConnectionNumber
Array Disk Channel Connection Number
Name
arrayDiskChannelConnectionNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.6.1.1
Description
Identifies the instance number of the array disk channel connection entry.
Syntax
Integer
Access
Read-only
Array Disk Channel Connection Array Disk Name
Name
arrayDiskChannelConnectionArrayDiskName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.6.1.2
Description
Identifies the name of the array disk in this connection as represented in
Storage Management.
Syntax
DisplayString
Access
Read-only
Storage Management Group
511
Array Disk Channel Connection Array Disk Number
Name
arrayDiskChannelConnectionArrayDiskNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.6.1.3
Description
Identifies the instance number of the array disk in the arrayDiskTable in this
connection.
Syntax
Integer
Access
Read-only
Array Disk Channel Connection Channel Name
Name
arrayDiskChannelConnectionChannelName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.6.1.4
Description
Identifies the name of the channel as represented in Storage Management to
which is array disk is connected.
Syntax
DisplayString
Access
Read-only
Array Disk Channel Connection Channel Number
Name
arrayDiskChannelConnectionChannelNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.6.1.5
Description
Identifies the instance number of the channel in the channelTable to which this
array disk is connected.
Syntax
Integer
Access
Read-only
Array Disk Channel Connection Controller Name
512
Name
arrayDiskChannelConnectionControllerName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.6.1.6
Description
Identifies the name of the controller as represented in Storage Management to
which this array disk is connected.
Syntax
DisplayString
Access
Read-only
Storage Management Group
Array Disk Channel Connection Controller Number
Name
arrayDiskChannelConnectionControllerNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.6.1.7
Description
Identifies the instance number in the controllerTable of the controller to which
this array disk is connected.
Syntax
Integer
Access
Read-only
Fan Table
This table describes available properties for each fan on the managed system.
The following object sets up the Fan Table.
Name
fanTable
Object ID
1.3.6.1.4.1.674.10893.1.20.130.7
Description
Defines the fan table.
Syntax
SEQUENCE OF FanEntry
Access
Not accessible
Fan Entry
Name
fanEntry
Object ID
1.3.6.1.4.1.674.10893.1.20.130.7.1
Description
Defines the fan table entry.
Syntax
FanEntry
Access
Not accessible
Index
fanNumber
Fan Number
Name
fanNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.7.1.1
Description
Identifies the instance number of the fan entry.
Syntax
Integer
Access
Read-only
Storage Management Group
513
Fan Name
Name
Fan Name
Object ID
1.3.6.1.4.1.674.10893.1.20.130.7.1.2
Description
Identifies the fan's name as represented in Storage Management.
Syntax
DisplayString
Access
Read-only
Fan Vendor
Name
fanVendor
Object ID
1.3.6.1.4.1.674.10893.1.20.130.7.1.3
Description
Identifies the fan's (re)seller's name.
Syntax
DisplayString
Access
Read-only
Fan State
Name
fanState
Object ID
1.3.6.1.4.1.674.10893.1.20.130.7.1.4
Description
Identifies the current state of the fan. Possible states:
0: Unknown
1: Ready
2: Failed
3: Online
4: Offline
6: Degraded
21: Missing
514
Syntax
Integer
Access
Read-only
Storage Management Group
Fan Severity
Name
fanSeverity
Object ID
1.3.6.1.4.1.674.10893.1.20.130.7.1.5
Description
This entry is obsolete for Storage Management. It was replaced with
RollUpStatus and ComponentStatus for each device.
Syntax
Integer
Access
Read-only
Fan Probe Unit
Name
fanProbeUnit
Object ID
1.3.6.1.4.1.674.10893.1.20.130.7.1.6
Description
This entry is obsolete for Storage Services.
Syntax
DisplayString
Access
Read-only
Fan Probe Minimum Warning
Name
fanProbeMinimumWarning
Object ID
1.3.6.1.4.1.674.10893.1.20.130.7.1.7
Description
This entry is obsolete. This setting is not supported by fans managed under
Storage Management.
Syntax
DisplayString
Access
Read-only
Fan Probe Minimum Critical
Name
fanProbeMinimumCritical
Object ID
1.3.6.1.4.1.674.10893.1.20.130.7.1.8
Description
This entry is obsolete. This setting is not supported by fans managed under
Storage Management.
Syntax
DisplayString
Access
Read-only
Storage Management Group
515
Fan Probe Maximum Warning
Name
fanProbeMaximumWarning
Object ID
1.3.6.1.4.1.674.10893.1.20.130.7.1.9
Description
This entry is obsolete. This setting is not supported by fans managed under
Storage Management.
Syntax
DisplayString
Access
Read-only
Fan Probe Maximum Critical
Name
fanProbeMaximumCritical
Object ID
1.3.6.1.4.1.674.10893.1.20.130.7.1.10
Description
This entry is obsolete. This setting is not supported by fans managed under
Storage Management.
Syntax
DisplayString
Access
Read-only
Fan Probe Current Value
Name
fanProbeCurrValue
Object ID
1.3.6.1.4.1.674.10893.1.20.130.7.1.11
Description
Identifies the current speed of the fan.
Syntax
DisplayString
Access
Read-only
Fan1 Part Number
516
Name
fan1PartNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.7.1.12
Description
Identifies the part number of the fan in the enclosure.
Syntax
DisplayString
Access
Read-only
Storage Management Group
Fan 2 Part Number
Name
fan2PartNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.7.1.13
Description
This entry is obsolete. This setting is not supported by fans managed under
Storage Management.
Syntax
DisplayString
Access
Read-only
Fan Roll-Up Status
Name
fanRollUpStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.130.7.1.14
Description
Severity of the fan state. This is the combined status of the fan and its
components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax
DellStatus
Access
Read-only
Fan Component Status
Name
fanComponentStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.130.7.1.15
Description
The status of the fan itself without the propagation of any contained component
status. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax
DellStatus
Access
Read-only
Storage Management Group
517
Fan Nexus ID
Name
fanNexusID
Object ID
1.3.6.1.4.1.674.10893.1.20.130.7.1.16
Description
Durable unique ID for this fan.
Syntax
DisplayString
Access
Read-only
Fan Revision
Name
fanRevision
Object ID
1.3.6.1.4.1.674.10893.1.20.130.7.1.17
Description
Indicates the revision number of the fan in the enclosure.
Syntax
DisplayString
Access
Read-only
Fan Connection Table
This table describes the connection between each fan on the managed system and its enclosure. Each
enclosure "number" in the table corresponds to that enclosure instance in the enclosure Table.
The following object sets up the Fan Connection Table.
Name
fanConnectionTable
Object ID
fanConnectionTable
Description
Defines the fan connection table.
Syntax
SEQUENCE OF FanConnectionEntry
Access
Not accessible
Fan Connection Entry
518
Name
fanConnectionEntry
Object ID
1.3.6.1.4.1.674.10893.1.20.130.8.1
Description
Defines the fan connection table entry.
Syntax
FanConnectionEntry
Access
Not accessible
Index
fanConnectionNumber
Storage Management Group
Fan Connection Number
Name
fanConnectionNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.8.1.1
Description
Identifies the instance number of the fan connection entry.
Syntax
Integer
Access
Read-only
Fan Connection Fan Name
Name
fanConnectionFanName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.8.1.2
Description
Identifies the name of the fan in this connection as represented in Storage
Management.
Syntax
DisplayString
Access
Read-only
Fan Connection Fan Number
Name
fanConnectionFanNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.8.1.3
Description
Identifies the instance number of the fan in the fanTable in the connection.
Syntax
Integer
Access
Read-only
Fan Connection Enclosure Name
Name
fanConnectionEnclosureName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.8.1.4
Description
Identifies the name of the enclosure as represented in Storage Management to
which this fan belongs.
Syntax
DisplayString
Access
Read-only
Storage Management Group
519
Fan Connection Enclosure Number
Name
fanConnectionEnclosureNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.8.1.5
Description
Identifies the instance number of the enclosure in the enclosureTable to which
this fan belongs.
Syntax
Integer
Access
Read-only
Power Supply Table
This table describes available properties for each power supply on the managed system.
The following object sets up the Power Supply Table.
Name
powerSupplyTable
Object ID
1.3.6.1.4.1.674.10893.1.20.130.9
Description
Defines the power supply table.
Syntax
SEQUENCE OF PowerSupplyEntry
Access
Not accessible
Power Supply Entry
Name
powerSupplyEntry
Object ID
1.3.6.1.4.1.674.10893.1.20.130.9.1
Description
Defines the power supply table entry.
Syntax
PowerSupplyEntry
Access
Not accessible
Index
powerSupplyNumber
Power Supply Number
520
Name
powerSupplyNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.9.1.1
Description
Identifies the instance number of the power supply entry.
Syntax
Integer
Access
Read-only
Storage Management Group
Power Supply Name
Name
powerSupplyName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.9.1.2
Description
Identifies the power supply's name as represented in Storage Management.
Syntax
DisplayString
Access
Read-only
Power Supply Vendor
Name
powerSupplyVendor
Object ID
1.3.6.1.4.1.674.10893.1.20.130.9.1.3
Description
Identifies the power supply's (re)seller's name.
Syntax
DisplayString
Access
Read-only
Power Supply State
Name
powerSupplyState
Object ID
1.3.6.1.4.1.674.10893.1.20.130.9.1.4
Description
Identifies the current state of the power supply. Possible states:
0: Unknown
1: Ready
2: Failed
5: Not Installed
6: Degraded
11: Removed
Syntax
Integer
Access
Read-only
Power Supply Severity
Name
powerSupplySeverity
Object ID
1.3.6.1.4.1.674.10893.1.20.130.9.1.5
Description
This entry is obsolete for Storage Management. It was replaced with
RollUpStatus and ComponentStatus for each device.
Syntax
Integer
Access
Read-only
Storage Management Group
521
Power Supply 1 Part Number
Name
powerSupply1PartNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.9.1.6
Description
Identifies the part number of the power supply of the enclosure.
Syntax
DisplayString
Access
Read-only
Power Supply 2 Part Number
Name
powerSupply2PartNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.9.1.7
Description
This entry is obsolete. This setting is not supported by power supplies managed
under Storage Management
Syntax
DisplayString
Access
Read-only
Power Supply Roll-Up Status
Name
powerSupplyRollUpStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.130.9.1.8
Description
Severity of the power supply state. This is the combined status of the power
supply and its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
522
Syntax
DellStatus
Access
Read-only
Storage Management Group
Power Supply Component Status
Name
powerSupplyComponentStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.130.9.1.9
Description
Severity of the power supply state. This is the combined status of the power
supply and its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax
DellStatus
Access
Read-only
Power Supply NexusID
Name
powerSupplyNexusID
Object ID
1.3.6.1.4.1.674.10893.1.20.130.9.1.10
Description
Durable unique ID for this power supply.
Syntax
DisplayString
Access
Read-only
Power Supply Revision
Name
powerSupplyRevision
Object ID
1.3.6.1.4.1.674.10893.1.20.130.9.1.11
Description
Indicates the revision number of the power supply in the enclosure.
Syntax
DisplayString
Access
Read-only
Storage Management Group
523
Power Supply Connection Table
This table describes the connection between each power supply on the managed system and its enclosure.
Each enclosure "number" in the table corresponds to that enclosure instance in the enclosure Table.
The following object sets up the Power Supply Connection Table.
Name
powerSupplyConnectionTable
Object ID
1.3.6.1.4.1.674.10893.1.20.130.10
Description
Defines the power supply connection table.
Syntax
SEQUENCE OF PowerSupplyConnectionEntry
Access
Not accessible
Power Supply Connection Entry
Name
powerSupplyConnectionEntry
Object ID
1.3.6.1.4.1.674.10893.1.20.130.10.1
Description
Defines the power supply connection table entry.
Syntax
PowerSupplyConnectionEntry
Access
Not accessible
Index
powerSupplyConnectionNumber
Power Supply Connection Number
Name
powerSupplyConnectionNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.10.1.1
Description
Identifies the instance number of the power supply connection entry.
Syntax
Integer
Access
Read-only
Power Supply Connection Power Supply Name
524
Name
powerSupplyConnectionPowerSupplyName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.10.1.2
Description
Identifies the name of the power supply in this connection as represented in
Storage Management.
Syntax
DisplayString
Access
Read-only
Storage Management Group
Power Supply Connection Power Supply Number
Name
powerSupplyConnectionPowerSupplyNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.10.1.3
Description
Identifies the instance number of the power supply in the powerSupplyTable in the connection.
Syntax
Integer
Access
Read-only
Power Supply Connection Enclosure Name
Name
powerSupplyConnectionEnclosureName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.10.1.4
Description
Identifies the name of the enclosure as represented in Storage Management to
which this power supply belongs.
Syntax
DisplayString
Access
Read-only
Power Supply Connection Enclosure Number
Name
powerSupplyConnectionEnclosureNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.10.1.5
Description
Identifies the instance number of the enclosure in the enclosureTable to which
this power supply belongs.
Syntax
Integer
Access
Read-only
Temperature Probe Table
This table describes available properties for each temperature probe on the managed system.
The following object sets up the Temperature Probe Table.
Name
temperatureProbeTable
Object ID
1.3.6.1.4.1.674.10893.1.20.130.11
Description
A table of managed temperature probes. The number of entries is related to the
number of temperature probes discovered in the system. The maximum number
of entries is implementation dependent.
NOTE: The properties in this table may not be applicable to all entries.
Syntax
SEQUENCE OF TemperatureProbeEntry
Access
Not accessible
Storage Management Group
525
Temperature Probe Entry
Name
temperatureProbeEntry
Object ID
1.3.6.1.4.1.674.10893.1.20.130.11.1
Description
An entry in the Temperature Probe Table. A row in this table cannot be created or
deleted by SNMP operations on columns of the table.
Syntax
TemperatureProbeEntry
Access
Not accessible
Index
TemperatureProbeNumber
Temperature Probe Number
Name
temperatureProbeNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.11.1.1
Description
Identifies the instance number of the temperature probe entry.
Syntax
Integer
Access
Read-only
Temperature Probe Name
Name
temperatureProbeName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.11.1.2
Description
Identifies the temperature probe's name as represented in Storage Management.
Syntax
DisplayString
Access
Read-only
Temperature Probe Vendor
526
Name
temperatureProbeVendor
Object ID
1.3.6.1.4.1.674.10893.1.20.130.11.1.3
Description
Identifies the temperature probe's (re)seller's name.
Syntax
DisplayString
Access
Read-only
Storage Management Group
Temperature Probe State
Name
temperatureProbeState
Object ID
1.3.6.1.4.1.674.10893.1.20.130.11.1.4
Description
Identifies the current state of the temperature probe. Possible states:
0: Unknown
1: Ready
2: Failed (Minimum Failure Threshold Exceeded, Maximum Failure
Threshold Exceeded)
4: Offline
6: Degraded (Minimum Warning Threshold Exceeded, Maximum Warning
Threshold Exceeded)
9: Inactive
21: Missing
Syntax
Integer
Access
Read-only
Temperature Probe Severity
Name
temperatureProbeSeverity
Object ID
1.3.6.1.4.1.674.10893.1.20.130.11.1.5
Description
This entry is obsolete for Storage Management. It was replaced with
RollUpStatus and ComponentStatus for each device.
Syntax
Integer
Access
Read-only
Temperature Probe Unit
Name
temperatureProbeUnit
Object ID
1.3.6.1.4.1.674.10893.1.20.130.11.1.6
Description
The units that will be used to display temperatures for the temperature probe.
Syntax
DisplayString
Access
Read-only
Storage Management Group
527
Temperature Probe Minimum Warning
Name
temperatureProbeMinWarning
Object ID
1.3.6.1.4.1.674.10893.1.20.130.11.1.7
Description
Identifies the minimum temperature that will force the probe into a warning state.
Syntax
Integer
Access
Read-only
Temperature Probe Minimum Critical
Name
temperatureProbeMinCritical
Object ID
1.3.6.1.4.1.674.10893.1.20.130.11.1.8
Description
Identifies the minimum temperature that will force the probe into an error state.
Syntax
Integer
Access
Read-only
Temperature Probe Maximum Warning
Name
temperatureProbeMaxWarning
Object ID
1.3.6.1.4.1.674.10893.1.20.130.11.1.9
Description
Identifies the maximum temperature that will force the probe into a
warning state.
Syntax
Integer
Access
Read-only
Temperature Probe Maximum Critical
528
Name
temperatureProbeMaxCritical
Object ID
1.3.6.1.4.1.674.10893.1.20.130.11.1.10
Description
Identifies the maximum temperature that will force the probe into an error state.
Syntax
Integer
Access
Read-only
Storage Management Group
Temperature Probe Current Value
Name
temperatureProbeCurValue
Object ID
1.3.6.1.4.1.674.10893.1.20.130.11.1.11
Description
Identifies the current temperature of this probe.
Syntax
Integer
Access
Read-only
Temperature Probe Roll-Up Status
Name
temperatureProbeRollUpStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.130.11.1.12
Description
Severity of the temperature probe state. This is the combined status of the
temperature probe and its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax
DellStatus
Access
Read-only
Temperature Probe Component Status
Name
temperatureProbeComponentStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.130.11.1.13
Description
The status of the temperature probe itself without the propagation of any
contained component status. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax
DellStatus
Access
Read-only
Storage Management Group
529
Temperature Probe Nexus ID
Name
temperatureProbeNexusID
Object ID
1.3.6.1.4.1.674.10893.1.20.130.11.1.14
Description
Durable unique ID for this temperature probe.
Syntax
DisplayString
Access
Read-only
Temperature Probe Connection Table
This table describes the connection between each temperature probe on the managed system and its enclosure.
Each enclosure "number" in the table corresponds to that enclosure instance in the enclosure Table.
The following object sets up the Temperature Probe Connection Table.
Name
temperatureConnectionTable
Object ID
1.3.6.1.4.1.674.10893.1.20.130.12
Description
Defines the temperature probe connection table.
Syntax
SEQUENCE OF TemperatureConnectionEntry
Access
Not accessible
Temperature Probe Connection Entry
Name
temperatureConnectionEntry
Object ID
1.3.6.1.4.1.674.10893.1.20.130.12.1
Description
Defines the temperature probe connection table entry.
Syntax
TemperatureConnectionEntry
Access
Not accessible
Index
temperatureConnectionNumber
Temperature Probe Connection Number
530
Name
temperatureConnectionNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.12.1.1
Description
Identifies the instance number of the temperature probe connection entry.
Syntax
Integer
Access
Read-only
Storage Management Group
Temperature Probe Connection Temperature Probe Name
Name
temperatureConnectionTemperatureName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.12.1.2
Description
Identifies the name of the temperature probe in this connection as represented in
Storage Management.
Syntax
DisplayString
Access
Read-only
Temperature Probe Connection Temperature Probe Number
Name
temperatureConnectionTemperatureNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.12.1.3
Description
Identifies the instance number in the temperatureTable of the temperature probe
in this connection.
Syntax
Integer
Access
Read-only
Temperature Probe Connection Enclosure Name
Name
temperatureConnectionEnclosureName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.12.1.4
Description
Identifies the name of the enclosure as represented in Storage Management to
which this temperature probe belongs.
Syntax
DisplayString
Access
Read-only
Temperature Probe Connection Enclosure Number
Name
temperatureConnectionEnclosureNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.12.1.5
Description
Identifies the instance number of the enclosure in the enclosureTable to which
this temperature probe belongs.
Syntax
Integer
Access
Read-only
Storage Management Group
531
Enclosure Management Module Table
This table describes available properties for each enclosure management module on the managed system.
The following object sets up the Enclosure Management Module Table.
Name
enclosureManagementModuleTable
Object ID
1.3.6.1.4.1.674.10893.1.20.130.13
Description
Defines the enclosure management module table.
Syntax
SEQUENCE OF EnclosureManagementModuleEntry
Access
Not accessible
Enclosure Management Module Entry
Name
EnclosureManagementModuleEntry
Object ID
1.3.6.1.4.1.674.10893.1.20.130.13.1
Description
Defines the enclosure management module table entry.
Syntax
EnclosureManagementModuleEntry
Access
Not accessible
Index
enclosureManagementModuleNumber
Enclosure Management Module Number
Name
enclosureManagementModuleNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.13.1.1
Description
Identifies the instance number of the enclosure management module entry.
Syntax
Integer
Access
Read-only
Enclosure Management Module Name
532
Name
enclosureManagementModuleName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.13.1.2
Description
Identifies the enclosure management module's name as represented in Storage
Management.
Syntax
DisplayString
Access
Read-only
Storage Management Group
Enclosure Management Module Vendor
Name
enclosureManagementModuleVendor
Object ID
1.3.6.1.4.1.674.10893.1.20.130.13.1.3
Description
Identifies the enclosure management module's (re)seller's name.
Syntax
DisplayString
Access
Read-only
Enclosure Management Module State
Name
enclosureManagementModuleState
Object ID
1.3.6.1.4.1.674.10893.1.20.130.13.1.4
Description
Identifies the current state of the enclosure management module. Possible states:
0: Unknown
1: Ready
2: Failed
3: Online
4: Offline
5: Not Installed
6: Degraded
21: Missing
Syntax
Integer
Access
Read-only
Enclosure Management Module Severity
Name
enclosureManagementModuleSeverity
Object ID
1.3.6.1.4.1.674.10893.1.20.130.13.1.5
Description
This entry is obsolete for Storage Management. It was replaced with
RollUpStatus and ComponentStatus for each device.
Syntax
Integer
Access
Read-only
Storage Management Group
533
Enclosure Management Module Part Number
Name
enclosureManagementModulePartNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.13.1.6
Description
Identifies the part number of the enclosure memory module.
Syntax
Display String
Access
Read-only
Enclosure Management Module Type
Name
enclosureManagementModuleType
Object ID
1.3.6.1.4.1.674.10893.1.20.130.13.1.7
Description
Identifies the type of the enclosure management module. Possible values:
0: Unknown
1: EMM
2: Termination Card
Syntax
Integer
Access
Read-only
Enclosure Management Module Firmware Version
Name
enclosureManagementModuleFWVersion
Object ID
1.3.6.1.4.1.674.10893.1.20.130.13.1.8
Description
Identifies the firmware version of the enclosure memory module.
Syntax
DisplayString
Access
Read-only
Enclosure Management Module Maximum Speed
534
Name
enclosureManagementModuleMaxSpeed
Object ID
1.3.6.1.4.1.674.10893.1.20.130.13.1.9
Description
Identifies the maximum bus speed of the enclosure management module.
Syntax
DisplayString
Access
Read-only
Storage Management Group
Enclosure Management Module Roll-Up Status
Name
enclosureManagementModuleRollUpStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.130.13.1.10
Description
Severity of the enclosure management module state. This is the combined status
of the EMM and its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax
DellStatus
Access
Read-only
Enclosure Management Module Component Status
Name
enclosureManagementModuleComponentStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.130.13.1.11
Description
The status of the enclosure management module itself without the propagation
of any contained component status. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax
DellStatus
Access
Read-only
Enclosure Management Module Nexus ID
Name
enclosureManagementModuleNexusID
Object ID
1.3.6.1.4.1.674.10893.1.20.130.13.1.12
Description
Durable unique ID for this EMM.
Syntax
DisplayString
Access
Read-only
Storage Management Group
535
Enclosure Management Module Revision
Name
enclosureManagementModuleRevision
Object ID
1.3.6.1.4.1.674.10893.1.20.130.13.1.13
Description
Identifies the revision number of the enclosure management module.
Syntax
DisplayString
Access
Read-only
Enclosure Management Module Connection Table
This table describes the connection between each enclosure management module on the managed
system and its enclosure. Each enclosure "number" in the table corresponds to that enclosure instance in
the enclosure Table.
The following object sets up the Enclosure Management Module Connection Table.
Name
enclosureManagementModuleConnectionTable
Object ID
1.3.6.1.4.1.674.10893.1.20.130.14
Description
Defines the enclosure memory module connection table.
Syntax
SEQUENCE OF EnclosureManagementModuleConnectionEntry
Access
Not accessible
Enclosure Management Module Connection Entry
Name
enclosureManagementModuleConnectionEntry
Object ID
1.3.6.1.4.1.674.10893.1.20.130.14.1
Description
Defines the enclosure memory module connection table entry.
Syntax
EnclosureManagementModuleConnectionEntry
Access
Not accessible
Index
enclosureManagementModuleConnectionNumber
Enclosure Management Module Connection Number
536
Name
enclosureManagementModuleConnectionNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.14.1.1
Description
Identifies the instance number of the enclosure memory module connection entry.
Syntax
Integer
Access
Read-only
Storage Management Group
Enclosure Management Module Connection EMM Name
Name
enclosureManagementModuleConnectionEMMName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.14.1.2
Description
Identifies the name of the enclosure memory module in this connection as
represented in Storage Management.
Syntax
DisplayString
Access
Read-only
Enclosure Management Module Connection EMM Number
Name
enclosureManagementModuleConnectionEMMNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.14.1.3
Description
Identifies the instance number in the enclosureManagementModuleTable of the
enclosure memory module in this connection.
Syntax
Integer
Access
Read-only
Enclosure Management Module Connection Enclosure Name
Name
enclosureManagementModuleConnectionEnclosureName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.14.1.4
Description
Identifies the name of the enclosure as represented in Storage Management to
which this enclosure memory module belongs.
Syntax
DisplayString
Access
Read-only
Enclosure Management Module Connection Enclosure Number
Name
enclosureManagementModuleConnectionEnclosureNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.14.1.5
Description
Identifies the instance number of the enclosure in the enclosureTable to which
this enclosure memory module belongs.
Syntax
Integer
Access
Read-only
Storage Management Group
537
Battery Table
This table describes available properties for each controller battery on the managed system.
The following object sets up the Battery Table.
Name
batteryTable
Object ID
1.3.6.1.4.1.674.10893.1.20.130.15
Description
Defines the battery table.
Syntax
SEQUENCE OF BatteryEntry
Access
Not accessible
Battery Entry
Name
batteryEntry
Object ID
1.3.6.1.4.1.674.10893.1.20.130.15.1
Description
Defines the battery table entry.
Syntax
BatteryEntry
Access
Not accessible
Index
batteryNumber
Battery Number
Name
batteryNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.15.1.1
Description
Identifies the instance number of the battery entry.
Syntax
Integer
Access
Read-only
Battery Name
538
Name
batteryName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.15.1.2
Description
Identifies the battery's name as represented in Storage Management.
Syntax
DisplayString
Access
Read-only
Storage Management Group
Battery Vendor
Name
batteryVendor
Object ID
1.3.6.1.4.1.674.10893.1.20.130.15.1.3
Description
Identifies the battery's (re)seller's name.
Syntax
DisplayString
Access
Read-only
Battery State
Name
batteryState
Object ID
1.3.6.1.4.1.674.10893.1.20.130.15.1.4
Description
Identifies the current state of battery. Possible values:
0: Unknown
1: OK
2: Failed
6: Degraded
7: Reconditioning
9: High
10: Low
12: Charging
21: Missing
36: Learning
Syntax
Integer
Access
Read-only
Storage Management Group
539
Battery Roll-Up Status
Name
batteryRollUpStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.130.15.1.5
Description
Severity of the battery state. This is the combined status of the battery and its
components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax
DellStatus
Access
Read-only
Battery Component Status
Name
batteryComponentStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.130.15.1.6
Description
The status of the battery itself without the propagation of any contained
component status. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax
DellStatus
Access
Read-only
Battery Charge Count
540
Name
batteryChargeCount
Object ID
1.3.6.1.4.1.674.10893.1.20.130.15.1.7
Description
The number of charges that have been applied to the battery.
Syntax
Integer
Access
Read-only
Storage Management Group
Battery Max Charge Count
Name
batteryMaxChargeCount
Object ID
1.3.6.1.4.1.674.10893.1.20.130.15.1.8
Description
The maximum number of charges that can be applied to the battery.
Syntax
Integer
Access
Read-only
Battery Nexus ID
Name
batteryNexusID
Object ID
1.3.6.1.4.1.674.10893.1.20.130.15.1.9
Description
Durable unique ID for this EMM.
Syntax
DisplayString
Access
Read-only
Battery Predicted Capacity
Name
batteryPredictedCapacity
Object ID
1.3.6.1.4.1.674.10893.1.20.130.15.1.10
Description
Displays the battery's ability to be charged.
Possible values:
1: Failed - The battery cannot be charged and needs to be replaced.
2: Ready - The battery can be charged to full capacity.
4: Unknown - The battery is completing a Learn cycle. The charge capacity of the
battery cannot be determined until the Learn cycle is complete.
Syntax
Integer
Access
Read-only
Battery Next Learn Time
Name
batteryNextLearnTime
Object ID
1.3.6.1.4.1.674.10893.1.20.130.15.1.11
Description
Indicates the time (in hours) the next learn cycle must be executed
Syntax
Integer
Access
Read-only
Storage Management Group
541
Battery Learn State
Name
batteryLearnState
Object ID
1.3.6.1.4.1.674.10893.1.20.130.15.1.12
Description
Specifies the learn state activity of the battery.
Possible values:
1: Failed
2: Active
4: Timed out
8: Requested
16: Idle
Syntax
Integer
Access
Read-only
Battery Maximum Learn Delay
Name
batteryMaxLearnDelay
Object ID
1.3.6.1.4.1.674.10893.1.20.130.15.1.14
Description
The maximum amount of time (in hours) that the battery learn cycle can be
delayed.
Syntax
Integer
Access
Read-only
Battery Connection Table
This table describes the connection between each controller battery on the managed system and its
controller. Each controller "number" in the table corresponds to that controller instance in the
controller Table.
The following object sets up the Battery Connection Table.
542
Name
batteryConnectionTable
Object ID
1.3.6.1.4.1.674.10893.1.20.130.16
Description
Defines the battery connection table.
Syntax
SEQUENCE OF BatteryConnectionEntry
Access
Not accessible
Storage Management Group
Battery Connection Entry
Name
batteryConnectionEntry
Object ID
1.3.6.1.4.1.674.10893.1.20.130.16.1
Description
Defines the battery connection table entry.
Syntax
BatteryConnectionEntry
Access
BatteryConnectionEntry
Index
BatteryConnectionNumber
Battery Connection Number
Name
batteryConnectionNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.16.1.1
Description
Identifies the instance number of the battery connection entry.
Syntax
Integer
Access
Read-only
Battery Connection Battery Name
Name
batteryConnectionBatteryName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.16.1.2
Description
Identifies the name of the battery in this connection as represented in
Storage Management.
Syntax
DisplayString
Access
Read-only
Battery Connection Battery Number
Name
batteryConnectionBatteryNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.16.1.3
Description
Identifies the instance number in the batteryTable of the battery in
this connection.
Syntax
Integer
Access
Read-only
Storage Management Group
543
Battery Connection Controller Name
Name
batteryConnectionControllerName
Object ID
1.3.6.1.4.1.674.10893.1.20.130.16.1.4
Description
Identifies the name of the controller as represented in Storage Management to
which this battery belongs.
Syntax
DisplayString
Access
Read-only
Battery Connection Controller Number
Name
batteryConnectionControllerNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.130.16.1.5
Description
Identifies instance number of the controller in the controllerTable to which this
battery belongs.
Syntax
Integer
Access
Read-only
Logical Devices Group
The Logical Devices Management Information Base (MIB) group provides information about the logical
devices managed by the Dell Storage Management Software and their relationships to each other.
This group and all of its associated tables and objects are not supported on Microsoft® Windows®
Advanced Server Limited Edition 64-bit operating system (Windows.Net-64) on a
Dell PowerEdge™ 7150. The following MIB tables define objects and relationships, or connections
among the objects, in the Logical Devices Group:
544
•
Virtual Disk Table—describes available properties for each virtual disk on the managed system.
•
Array Disk Logical Connection Table—describes the connections between array disks, the virtual disk
to which they belong, and their associated logical disk. For each object in the table, its object "number"
corresponds to an instance number in the appropriate MIB table for that object where all of the object
properties can be found.
Storage Management Group
Virtual Disk Table
This table describes available properties for each virtual disk on the managed system.
The following object sets up the Virtual Disk Table.
Name
virtualDiskTable
Object ID
1.3.6.1.4.1.674.10893.1.20.140.1
Description
Defines the virtual disk table.
Syntax
SEQUENCE OF VirtualDiskEntry
Access
Not accessible
Virtual Disk Entry
Name
virtualDiskEntry
Object ID
1.3.6.1.4.1.674.10893.1.20.140.1.1
Description
Defines the virtual disk table entry.
Syntax
VirtualDiskEntry
Access
Not accessible
Index
virtualDiskNumber
Virtual Disk Number
Name
virtualDiskNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.140.1.1.1
Description
Identifies the instance number of the virtual disk entry.
Syntax
Integer
Access
Read-only
Virtual Disk Name
Name
virtualDiskName
Object ID
1.3.6.1.4.1.674.10893.1.20.140.1.1.2
Description
Identifies the virtual disk's label generated by Storage Management or entered by
the user.
Syntax
DisplayString
Access
Read-only
Storage Management Group
545
Virtual Device Disk Name
Name
virtualDiskDeviceName
Object ID
1.3.6.1.4.1.674.10893.1.20.140.1.1.3
Description
Identifies the device name used by this virtual disk's member disks.
Syntax
DisplayString
Access
Read-only
Virtual Disk State
Name
virtualDiskState
Object ID
1.3.6.1.4.1.674.10893.1.20.140.1.1.4
Description
Identifies the current state of this virtual disk. Possible states:
0: Unknown
1: Ready - The disk is accessible and has no known problems.
2: Failed - The data on the virtual disk is no longer fault tolerant because one of
the underlying disks is not online.
3: Online
4: Offline - The disk is not accessible. The disk may be corrupted or
intermittently unavailable.
6: Degraded - The data on the virtual disk is no longer fault tolerant because one
of the underlying disks is not online.
15: Resynching
16: Regenerating
24: Rebuilding
26: Formatting
32: Reconstructing
35: Initializing
36: Background Initialization
52: Permanently Degraded
546
Syntax
Integer
Access
Read-only
Storage Management Group
Virtual Disk Severity
Name
virtualDiskSeverity
Object ID
1.3.6.1.4.1.674.10893.1.20.140.1.1.5
Description
This entry is obsolete for Storage Management. It was replaced with
RollUpStatus and ComponentStatus for each device.
Syntax
Integer
Access
Read-only
Virtual Disk Length in Megabytes
Name
virtualDiskLengthInMB
Object ID
1.3.6.1.4.1.674.10893.1.20.140.1.1.6
Description
Identifies the size of this virtual disk in megabytes. If this size is 0, it is smaller
than a megabyte.
Syntax
Integer
Access
Read-only
Virtual Disk Length in Bytes
Name
virtualDiskLengthBytes
Object ID
1.3.6.1.4.1.674.10893.1.20.140.1.1.7
Description
Identifies the portion of the virtual disk in bytes that is smaller than a megabyte.
This size plus the virtualDiskLengthInMB is the total size of the virtual disk.
Syntax
Integer
Access
Read-only
Virtual Disk Free Space in Megabytes
Name
virtualDiskFreeSpaceInMB
Object ID
1.3.6.1.4.1.674.10893.1.20.140.1.1.8
Description
This entry is obsolete. This property is not supported by virtual disks managed
under Storage Management.
Syntax
Integer
Access
Read-only
Storage Management Group
547
Virtual Disk Free Space in Bytes
Name
virtualDiskFreeSpaceInBytes
Object ID
1.3.6.1.4.1.674.10893.1.20.140.1.1.9
Description
This entry is obsolete. This property is not supported by virtual disks managed
under Storage Management.
Syntax
Integer
Access
Read-only
Virtual Disk Write Policy
Name
virtualDiskWritePolicy
Object ID
1.3.6.1.4.1.674.10893.1.20.140.1.1.10
Description
Indicates whether the controller's write cache will be used when writing to a
virtual disk. Possible values:
1: Enabled - Adaptec Write Cache Enabled Protected
2: Disabled - Adaptec Write Cache Disabled
3: LSI Write Back
4: LSI Write Through
5: Enabled Always - (Adaptec only)
6: Enabled Always - (SAS only)
Syntax
Integer
Access
Read-only
Virtual Disk Read Policy
Name
virtualDiskReadPolicy
Object ID
1.3.6.1.4.1.674.10893.1.20.140.1.1.11
Description
Indicates whether the controller's read cache will be used when reading from a
virtual disk. Possible values:
1: Enabled - Adaptec Read Cache Enabled
2: Disabled - Adaptec Read Cache Disabled
3: LSI Read Ahead
4: LSI Adaptive Read Ahead
5: LSI No Read Ahead
548
Syntax
Integer
Access
Read-only
Storage Management Group
Virtual Disk Cache Policy
Name
virtualDiskCachePolicy
Object ID
1.3.6.1.4.1.674.10893.1.20.140.1.1.12
Description
Indicates whether the controller's cache is used when reading from or writing to a
virtual disk. Possible values:
1: Direct I/O (LSI)
2: Cached I/O (LSI)
99: Not Applicable
Syntax
Integer
Access
Read-only
Virtual Disk Layout
Name
virtualDiskLayout
Object ID
1.3.6.1.4.1.674.10893.1.20.140.1.1.13
Description
Indicates the virtual disk's RAID type. Possible values:
1: Concatenated
2: RAID-0
3: RAID-1
7: RAID-5
10: RAID-10
12: RAID-50
19: Concatenated RAID 1
Syntax
Integer
Access
Read-only
Virtual Disk Current Stripe Size in Megabytes
Name
virtualDiskCurStripeSizeInMB
Object ID
1.3.6.1.4.1.674.10893.1.20.140.1.1.14
Description
Identifies the stripe size of this virtual disk in megabytes. If this size is 0, it is
smaller than a megabyte.
Syntax
Integer
Access
Read-only
Storage Management Group
549
Virtual Disk Current Stripe Size in Bytes
Name
virtualDiskCurStripeSizeInBytes
Object ID
1.3.6.1.4.1.674.10893.1.20.140.1.1.15
Description
Identifies the portion of the stripe size in bytes that is smaller than a megabyte.
This size plus the virtualDiskCurStripeSizeInMB is the total stripe size on the
virtual disk.
Syntax
Integer
Access
Read-only
Virtual Disk Channel
Name
virtualDiskChannel
Object ID
1.3.6.1.4.1.674.10893.1.20.140.1.1.16
Description
This entry is obsolete. This property is not supported by virtual disks managed
under Storage Management.
Syntax
Integer
Access
Read-only
Virtual Disk Target ID
Name
virtualDiskTargetID
Object ID
1.3.6.1.4.1.674.10893.1.20.140.1.1.17
Description
Unique ID for the virtual disk.
Syntax
Integer
Access
Read-only
Virtual Disk LUN ID
550
Name
virtualDiskLunID
Object ID
1.3.6.1.4.1.674.10893.1.20.140.1.1.18
Description
This entry is obsolete. This property is not supported by virtual disks managed
under Storage Management.
Syntax
Integer
Access
Read-only
Storage Management Group
Virtual Disk Roll-Up Status
Name
virtualDiskRollUpStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.140.1.1.19
Description
Severity of the virtual disk state. This is the combined status of the virtual disk
and its components. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax
DellStatus
Access
Read-only
Virtual Disk Component Status
Name
virtualDiskComponentStatus
Object ID
1.3.6.1.4.1.674.10893.1.20.140.1.1.20
Description
The status of the virtual disk itself without the propagation of any contained
component status. Possible values:
1: Other
2: Unknown
3: OK
4: Non-critical
5: Critical
6: Non-recoverable
Syntax
DellStatus
Access
Read-only
Virtual Disk Nexus ID
Name
virtualDiskNexusID
Object ID
1.3.6.1.4.1.674.10893.1.20.140.1.1.21
Description
Durable unique ID for this virtual disk.
Syntax
DisplayString
Access
Read-only
Storage Management Group
551
Virtual Disk Array Disk Type
Name
virtualDiskArrayDiskType
Object ID
1.3.6.1.4.1.674.10893.1.20.140.1.1.22
Description
Identifies the type of array (physical) disks used to create the virtual disk.
Possible values:
1: SAS
2: SATA
3: SCSI
4: IDE
99: Unknown
Syntax
Integer
Access
Read-only
Array Disk Logical Connection Table
This table describes the connections between array disks, the virtual disk to which they belong, and
their associated logical disk. For each object in the table, its object "number" corresponds to an instance
number in the appropriate MIB table for that object where all of the object properties can be found.
The following object sets up the Array Disk Logical Connection Table.
Name
arrayDiskLogicalConnectionTable
Object ID
1.3.6.1.4.1.674.10893.1.20.140.3
Description
Defines the array disk logical connection table.
Syntax
SEQUENCE OF arrayDiskLogicalConnectionEntry
Access
Not accessible
Array Disk Logical Connection Entry
552
Name
arrayDiskLogicalConnectionEntry
Object ID
1.3.6.1.4.1.674.10893.1.20.140.3.1
Description
Defines the array disk logical connection table entry.
Syntax
ArrayDiskLogicalConnectionEntry
Access
Not accessible
Index
arrayDiskLogicalConnectionNumber
Storage Management Group
Array Disk Logical Connection Number
Name
arrayDiskLogicalConnectionNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.140.3.1.1
Description
Identifies the instance number of the disk entry.
Syntax
Integer
Access
Read-only
Array Disk Logical Connection Array Disk Name
Name
arrayDiskLogicalConnectionArrayDiskName
Object ID
1.3.6.1.4.1.674.10893.1.20.140.3.1.2
Description
Identifies the name of the array disk in this logical connection.
Syntax
DisplayString
Access
Read-only
Array Disk Logical Connection Array Disk Number
Name
arrayDiskLogicalConnectionArrayDiskNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.140.3.1.3
Description
Identifies the instance number of the array disk in this logical connection.
Syntax
Integer
Access
Read-only
Array Disk Logical Connection Virtual Disk Name
Name
arrayDiskLogicalConnectionVirtualDiskName
Object ID
1.3.6.1.4.1.674.10893.1.20.140.3.1.4
Description
Identifies the name of the virtual disk to which this array disk belongs.
Syntax
DisplayString
Access
Read-only
Storage Management Group
553
Array Disk Logical Connection Virtual Disk Number
Name
arrayDiskLogicalConnectionVirtualDiskNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.140.3.1.5
Description
Identifies the instance number of the virtual disk to which this array disk belongs.
Syntax
Integer
Access
Read-only
Array Disk Logical Connection Disk Name
Name
arrayDiskLogicalConnectionDiskName
Object ID
1.3.6.1.4.1.674.10893.1.20.140.3.1.6
Description
Identifies the name of the disk group to which this array disk belongs. This
property is currently not supported.
Syntax
DisplayString
Access
Read-only
Array Disk Logical Connection Disk Number
Name
arrayDiskLogicalConnectionDiskNumber
Object ID
1.3.6.1.4.1.674.10893.1.20.140.3.1.7
Description
Identifies the instance number of the disk group to which this array disk belongs.
This property is currently not supported.
Syntax
Integer
Access
Read-only
Storage Management Event Group
The Storage Management Event Group defines the properties that will be sent with SNMP traps.
Message ID Event
554
Name
messageIDEvent
Object ID
1.3.6.1.4.1.674.10893.1.20.200.1
Description
Storage Management event message number.
Syntax
Integer
Access
Read-only
Storage Management Group
Description Event
Name
descriptionEvent
Object ID
1.3.6.1.4.1.674.10893.1.20.200.2
Description
Storage Management event message text describing the alert.
Syntax
DisplayString
Access
Read-only
Location Event
Name
locationEvent
Object ID
1.3.6.1.4.1.674.10893.1.20.200.3
Description
Additional information identifying the location of the object causing the alert.
Syntax
DisplayString
Access
Read-only
Object Name Event
Name
objectNameEvent
Object ID
1.3.6.1.4.1.674.10893.1.20.200.4
Description
Name of the object as represented in Storage Management causing the alert.
Syntax
DisplayString
Access
Read-only
Object OID Event
Name
objectOIDEvent
Object ID
1.3.6.1.4.1.674.10893.1.20.200.5
Description
MIB OID of the object causing the alert.
Syntax
DisplayString
Access
Read-only
Storage Management Group
555
Object Nexus Event
Name
objectNexusEvent
Object ID
1.3.6.1.4.1.674.10893.1.20.200.6
Description
Durable, unique ID of the object causing the alert.
Syntax
DisplayString
Access
Read-only
Current Status Event
Name
currentStatusEvent
Object ID
1.3.6.1.4.1.674.10893.1.20.200.7
Description
Current status of object causing the alert, if applicable.
Syntax
DellStatus
Access
Read-only
Previous Status Event
556
Name
previousStatusEvent
Object ID
1.3.6.1.4.1.674.10893.1.20.200.8
Description
Previous status of object causing the alert if applicable.
Syntax
DellStatus
Access
Read-only
Storage Management Group
Change Management Group
The Change Management Group lets you monitor information about the Dell™ devices and
software that are present on a particular managed computer chassis. This information is collected
during an inventory scan.
Inventory Group
The following objects describe the fields for inventory information.
Inventory Locale
Name
inventoryLocale
Object ID
1.3.6.1.4.1.674.10899.1.1
Description
Defines the locale of the system.
Syntax
DisplayString
Access
Read-only
Inventory Schema Version
Name
inventorySchemaVersion
Object ID
1.3.6.1.4.1.674.10899.1.2
Description
Defines the inventory schema implemented by this system.
Syntax
DisplayString
Access
Read-only
Inventory System ID
Name
inventorySystemID
Object ID
1.3.6.1.4.1.674.10899.1.3
Description
Defines the System ID for the system.
Syntax
SystemID
Access
Read-only
Change Management Group
557
Device Group
The Device Group defines information about the devices discovered on the system during an inventory
scan. Identifying information includes the Component ID, the Device ID, and the Vendor ID.
Device Group Table
The following object sets up the Device Group Table.
Name
deviceTable
Object ID
1.3.6.1.4.1.674.10899.1.5
Description
Defines the Device Table.
Syntax
SEQUENCE OF DeviceEntry
Access
Not accessible
Device Entry
Name
deviceEntry
Object ID
1.3.6.1.4.1.674.10899.1.5.1
Description
Defines a device entry.
Syntax
DeviceEntry
Access
Not accessible
Device Index
Name
deviceIndex
Object ID
1.3.6.1.4.1.674.10899.1.5.1.1
Description
Defines the unique index for this device.
Syntax
Unsigned16BitRange
Access
Read-only
Device Component ID
558
Name
deviceComponentID
Object ID
1.3.6.1.4.1.674.10899.1.5.1.2
Description
Defines an optional component ID field for the device.
Syntax
Integer
Access
Read-only
Change Management Group
Device Display String
Name
deviceDisplayString
Object ID
1.3.6.1.4.1.674.10899.1.5.1.3
Description
Provides a displayable string that describes the device.
Syntax
DisplayString
Access
Read-only
Device Vendor ID
Name
deviceVendorID
Object ID
1.3.6.1.4.1.674.10899.1.5.1.4
Description
Defines the ID for the vendor supplying the device.
Syntax
Octet String
Access
Read-only
Device ID
Name
deviceDeviceID
Object ID
1.3.6.1.4.1.674.10899.1.5.1.5
Description
Defines the ID for the device.
Syntax
Octet String
Access
Read-only
Device Sub ID
Name
deviceSubID
Object ID
1.3.6.1.4.1.674.10899.1.5.1.6
Description
Provides additional device identification.
Syntax
Octet String
Access
Read-only
Change Management Group
559
Device Sub Vendor ID
Name
deviceSubVendorID
Object ID
1.3.6.1.4.1.674.10899.1.5.1.7
Description
Provides additional vendor identification.
Syntax
Octet String
Access
Read-only
Application Group
NOTE: Dell updateable components such as Basic input/output system (BIOS) and FirmWare (FW) are considered
applications. For example, the following would be returned for system BIOS:
Application/DisplayString = BIOS
Application/Version = A10
The Application Group defines information about the applications discovered on the system during an
inventory scan. Identifying information includes the application type, the application version, and the
application description.
Application Group Table
The following object sets up the Application Group Table.
Name
applicationTable
Object ID
1.3.6.1.4.1.674.10899.1.6
Description
Defines a table of application information for the system.
Syntax
SEQUENCE OF ApplicationEntry
Access
Not accessible
Application Entry
560
Name
applicationEntry
Object ID
1.3.6.1.4.1.674.10899.1.6.1
Description
Defines an application entry.
Syntax
ApplicationEntry
Access
Read-only
Change Management Group
Application Index
Name
applicationIndex
Object ID
1.3.6.1.4.1.674.10899.1.6.1.1
Description
Defines the unique index for this application.
Syntax
Unsigned16BitRange
Access
Read-only
Application Device Index
Name
applicationDeviceIndex
Object ID
1.3.6.1.4.1.674.10899.1.6.1.2
Description
Defines a cross-index to the device table for the application.
Syntax
Unsigned16BitRange
Access
Read-only
Application Component Type
Name
applicationComponentType
Object ID
1.3.6.1.4.1.674.10899.1.6.1.3
Description
Identifies the type of application reported.
Syntax
DisplayString
Access
Read-only
Application Version
Name
applicationVersion
Object ID
1.3.6.1.4.1.674.10899.1.6.1.4
Description
Identifies the version of the application.
Syntax
DisplayString
Access
Read-only
Change Management Group
561
Application Display String
Name
applicationDisplayString
Object ID
1.3.6.1.4.1.674.10899.1.6.1.5
Description
A user visible display string that describes the application.
Syntax
DisplayString
Access
Read-only
Application Sub-Component ID
Name
applicationSubComponentID
Object ID
1.3.6.1.4.1.674.10899.1.6.1.6
Description
The sub-component ID for the application. This is usually valid on
ESM device reporting.
Syntax
DisplayString
Access
Read-only
Operating System Group
The Operating System Group provides status and identifying information about a system’s operating system.
Identifying information includes the name, version, and service pack of the installed operating system.
The following objects describe the fields for Operating System Group.
Operating System Vendor
Name
operatingSystemVendor
Object ID
1.3.6.1.4.1.674.10899.2.1
Description
Defines the vendor of the Operating System.
Syntax
DisplayString
Access
Read-only
Operating System Major Version
562
Name
operatingSystemMajorVersion
Object ID
1.3.6.1.4.1.674.10899.2.2
Description
Defines the major version of the Operating System.
Syntax
DisplayString
Access
Read-only
Change Management Group
Operating System Minor Version
Name
operatingSystemMinorVersion
Object ID
1.3.6.1.4.1.674.10899.2.3
Description
Defines the minor version of the Operating System.
Syntax
DisplayString
Access
Read-only
Operating System Service Pack Major Version
Name
operatingSystemSPMajorVersion
Object ID
1.3.6.1.4.1.674.10899.2.5
Description
Defines the Operating System's Service Pack major version.
Syntax
DisplayString
Access
Read-only
Operating System Service Pack Minor Version
Name
operatingSystemSPMinorVersion
Object ID
1.3.6.1.4.1.674.10899.2.6
Description
Defines the Operating System's Service Pack minor version.
Syntax
DisplayString
Access
Read-only
Operating System Architecture
Name
operatingSystemArchitecture
Object ID
1.3.6.1.4.1.674.10899.2.7
Description
Defines the Operating System's architecture.
Syntax
DisplayString
Access
Read-only
Change Management Group
563
Inventory Collector Product Information
The following objects describe the fields for the Inventory Collector. The Inventory Collector product
variables are scalar objects, meaning that they are not related to other Inventory Collector base (MIB)
objects and are thus not placed in a table.
Product ID Display Name
Name
productIDDisplayName
Object ID
1.3.6.1.4.1.674.10899.100.1
Description
Defines the display name of the product.
Syntax
DisplayString
Access
Read-only
Product ID Description
Name
productIDDescription
Object ID
1.3.6.1.4.1.674.10899.100.2
Description
Provides a description of the product.
Syntax
DisplayString
Access
Read-only
Product ID Vendor
564
Name
productIDVendor
Object ID
1.3.6.1.4.1.674.10899.100.3
Description
Provides name of the manufacturer of the product.
Syntax
DisplayString
Access
Read-only
Change Management Group
Product ID Version
Name
productIDVersion
Object ID
1.3.6.1.4.1.674.10899.100.4
Description
Describes the version of the product.
Syntax
DisplayString
Access
Read-only
Product ID Build Number
Name
productIDBuildNumber
Object ID
1.3.6.1.4.1.674.10899.100.5
Description
Describes the software build number of the product.
Syntax
DisplayString
Access
Read-only
Change Management Group
565
566
Change Management Group
Traps
The Server Administrator generates events that result in Simple Network Management Protocol (SNMP)
traps or operating system event logs. Remote Access Controller (RAC) and Baseboard Management
Controller (BMC) also can generate SNMP traps in response to hardware events. This section
describes the traps, also known as alerts, generated by the Server Administrator, RAC, and BMC.
The Server Administrator generates events in response to changes in the status of sensors and other
monitored parameters. When an event with predefined characteristics occurs on your system, the
SNMP subagent sends information about the event, along with trap variables, to the
management console.
Each status change event generates a unique identifier called the trap ID and a trap description that
describes the event. The trap ID and message uniquely describe the severity and cause of the event,
and provide other relevant information such as the location of the event and the monitored item’s
previous state.
"Instrumentation Traps," found later in this section, lists all Server Administrator Instrumentation
trap IDs in numerical order and includes each trap ID’s corresponding description, severity level, and
cause. Description text in brackets (for example, <State>) describes the event-specific information
provided by Server Administrator.
"RAC Traps," found later in this section, lists RAC trap IDs in numerical order and includes each
trap ID’s corresponding description, severity level, and cause.
"BMC Traps," found later in this section, lists BMC trap IDs and includes each trap ID’s
corresponding description and severity level.
Trap Variables
This section describes the variables that are sent to the management console to provide additional
information about a trap or alert generated by some event on your system. The trap variables
presented here apply to all Instrumentation and RAC traps. Trap variables are sent in the order listed
and are reserved for use only in traps. When a varbind is created for a trap variable, a zero is
appended to the object ID (OID) to create the OID for the varbind.
Traps
567
System
Variable Name
alertSystem
Object ID
1.3.6.1.4.1.674.10892.1.5000.10.1
Description
Identifies the system generating the alert.
Syntax
DisplayString (SIZE (0..255))
Table Index OID
Variable Name
alertTableIndexOID
Object ID
1.3.6.1.4.1.674.10892.1.5000.10.2
Description
Gives the object identifier for the index attribute in the table
that contains the object causing the alert. Uniquely identifies
the object causing the alert and can be used to correlate
different alerts caused by the same object.
Syntax
OBJECT IDENTIFIER
Message
Variable Name
alertMessage
Object ID
1.3.6.1.4.1.674.10892.1.5000.10.3
Description
Describes the alert.
Syntax
DisplayString (SIZE (0..1024))
Current Status
Variable Name
alertCurrentStatus
Object ID
1.3.6.1.4.1.674.10892.1.5000.10.4
Description
Gives the current status of the object causing the alert.
Syntax
DellStatus
Previous Status
568
Variable Name
alertPreviousStatus
Object ID
1.3.6.1.4.1.674.10892.1.5000.10.5
Description
Gives the previous status of the object causing the alert.
Syntax
DellStatus
Traps
Data
Variable Name
alertData
Object ID
1.3.6.1.4.1.674.10892.1.5000.10.6
Description
Provides Server Administrator-defined data related to the alert.
Syntax
OCTET STRING (SIZE (0..1024))
Understanding the Trap Description
Table 25-1 lists in alphabetical order each line item that may appear in the trap description.
Table 25-1.
Trap Description Reference
Description Line Item
Explanation
Action performed was: <Action>
Specifies the automatic server recovery action that was performed,
for example:
Action performed was: Power cycle
Action requested was: <Action>
Specifies the user initiated host control action that was requested,
for example:
Action requested was: Reboot, shutdown OS first
Additional details: <Additional
details for the events>
Specifies possible additional details about the specified device, for
example:
Additional details:
Memory device: DIMM_1A Serial number: 11111111
Memory device: DIMM_1B Serial number: 22222222
<Additional power supply status
information>
Specifies any additional power supply information pertaining to
the event, for example:
Power supply input AC is off, Power supply POK
(power OK) signal is not normal, Power supply
is turned off
Battery sensor status: <status>
Specifies the status reported by the battery sensor, for example:
Battery sensor status: Predictive failure
Chassis intrusion state:
Specifies the chassis intrusion state (open or closed), for example:
<Intrusion state>
Chassis intrusion state: Open
Chassis location:
Specifies the name of the chassis that generated the message,
for example:
<Name of chassis>
Chassis location: Main System Chassis
Traps
569
Table 25-1.
Trap Description Reference (continued)
Description Line Item
Explanation
Configuration error type: <type
of configuration error>
Specifies the type of configuration error that occurred,
for example:
Configuration error type: Revision mismatch
Current sensor value (in Amps):
<Reading>
Specifies the current sensor value in amps, for example:
Date and time of action: <Date
and time>
Specifies the date and time that an automatic server recovery
action was performed, for example:
Current sensor value: 7.853
Date and time of action:
Fri May 30 23:55:44 2003.
Device location: <Location in
chassis>
Specifies the location of the device in the specified chassis, for
example:
Device location: Mem Card A
Discrete current state: <State>
Specifies the state of the current sensor, for example:
Discrete current state: Good
Discrete temperature state:
<State>
Specifies the state of the temperature sensor, for example:
Discrete voltage state: <State>
Specifies the state of the voltage sensor, for example:
Discrete temperature state: Good
Discrete voltage state: Good
Fan sensor value: <Reading>
Specifies the fan speed in revolutions per minute (RPMs) or
On/Off, for example:
Fan sensor value (in RPM): 2600
Fan sensor value: Off
Log type: <Log type>
Specifies the type of hardware log, for example:
Log type: Embedded Server Management (ESM)
Memory device bank location:
<Bank name in chassis>
Specifies the name of the memory bank in the system that
generated the message, for example:
Memory device bank location: Bank_1
Memory device location:
<Device name in chassis>
Specifies the location of the memory module in the chassis,
for example:
Memory device location: DIMM_A
Number of devices required for
full redundancy: <Number>
Specifies the number of power supply or cooling devices required
to achieve full redundancy, for example:
Number of devices required for full
redundancy: 4
570
Traps
Table 25-1.
Trap Description Reference (continued)
Description Line Item
Explanation
Possible memory module event
cause: <list of causes>
Specifies a list of possible causes for the memory module event,
for example:
Possible memory module event cause: Single bit
warning error rate exceeded
Single bit error logging disabled
Power Supply type: <type of power Specifies the type of power supply, for example:
supply>
Power Supply type: VRM
Pre-failure state was: <State>
Specifies the status of the previous memory message, for example:
Pre-failure state was: Failed
Previous redundancy state was:
<State>
Specifies the status of the previous redundancy message,
for example:
Previous redundancy state was: Lost
Previous state was: <State>
Specifies the previous state of the sensor, for example:
Previous state was: OK (Normal)
Processor sensor status:
Specifies the status of the processor sensor, for example:
<status>
Processor sensor status: Configuration error
Specifies the location of the redundant power supply or cooling
<Redundancy location in chassis> unit in the chassis, for example:
Redundancy unit: Fan Enclosure
Redundancy unit:
Sensor location:
<Location in chassis>
Specifies the location of the sensor in the specified chassis,
for example:
Sensor location: CPU1
Temperature sensor value (in
degrees Celsius):
Specifies the temperature in degrees Celsius, for example:
Temperature sensor value (in degrees Celsius): 30
<Reading>
Voltage sensor value (in Volts):
Specifies the voltage sensor value in volts, for example:
<Reading>
Voltage sensor value: 1.693
Traps
571
Understanding Trap Severity
Traps often contain information about values recorded by probes or sensors. Probes and sensors monitor
critical components for values such as amperage, voltage, and temperature. When an event occurs on
your system, the Server Administrator sends information about one of the following event types to the
system management console:
•
Information/Informational — An event that describes the successful operation of a unit, such as a
power supply turning on or a sensor reading returning to normal.
•
Warning — An event that is not necessarily significant, but may indicate a possible future problem,
such as crossing a warning threshold.
•
Critical/Error — A significant event that indicates actual or imminent loss of data or loss of function,
such as crossing a failure threshold or a hardware failure.
Instrumentation Traps
This section describes the traps that are generated by the Instrumentation service of the Server
Administrator. All of the traps documented in this section belong to the MIB enterprise identified by
OID 1.3.6.1.4.1.674.10892.1 and are sent with all of the trap variables documented in the section, "Trap
Variables." The trap variables are sent in the order in which they are listed. The messages in the
Description fields below show the format of the message that is sent in the alertMessage varbind. If a
message in a Description field has multiple lines, the message contains newline (0Ah) characters that are
part of the value in the alertMessage varbind.
572
Traps
Miscellaneous Traps
Miscellaneous traps inform you that certain alert systems are up and working.
Table 25-2.
Trap
ID
Miscellaneous Traps
Description
Severity
Cause
Information
Server Administrator completed its initialization.
Error
This message is generated when a system is
configured for thermal shutdown due to an error
event. If a temperature sensor reading exceeds the
error threshold for which the system is
configured, the operating system shuts down and
the system powers off. This event may also be
initiated on certain systems when a fan enclosure
is removed from the system for an extended
period of time.
1006 Automatic System Recovery Error
(ASR) action was performed
This message is generated when an automatic
system recovery action is performed due to a hung
operating system. The action performed and the
date and time of the action are provided.
System Up
1001 Server Administrator
startup complete
Thermal Shutdown
1004 Thermal shutdown
protection has been
initiated
Automatic System Recovery
Action performed was:
<Action>
Date and time of action:
<Date and time>
Host System Reset
1007 User initiated host system Information
control action
Action requested was:
<Action>
User requested a host system control action to
reboot, power off, or power cycle the system or
another event such as thermal shutdown
protection initiated a power off, operating
system shutdown.
Traps
573
Temperature Probe Traps
Temperature probes help protect critical components by alerting the systems management console when
temperatures become too high inside a chassis. The temperature probe traps use additional variables:
sensor location, chassis location, previous state, and temperature sensor value reported in degrees Celsius.
Table 25-3.
Temperature Probe Traps
Trap ID Description
Severity
Cause
Information
A temperature sensor on the
backplane board, system
board, or drive carrier in the
specified system returned to a
valid range after crossing a
failure threshold. The sensor
location, chassis location,
previous state, and
temperature sensor value are
provided.
Warning
A temperature sensor on the
backplane board, system
board, or drive carrier in the
specified system exceeded its
warning threshold. The sensor
location, chassis location,
previous state, and
temperature sensor value are
provided.
Temperature Probe Normal
1052
Temperature sensor returned to a
normal value
Sensor location: <Location in chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
If sensor type is not discrete:
Temperature sensor value (in degrees
Celsius): <Reading>
If sensor type is discrete: Discrete
temperature state: <State>
Temperature Probe Warning
1053
Temperature sensor detected a
warning value
Sensor location: <Location in chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
If sensor type is not discrete:
Temperature sensor value (in degrees
Celsius): <Reading>
If sensor type is discrete: Discrete
temperature state: <State>
574
Traps
Table 25-3.
Temperature Probe Traps (continued)
Trap ID Description
Severity
Cause
Error
A temperature sensor on the
backplane board, system
board, or drive carrier in the
specified system exceeded its
failure threshold. The sensor
location, chassis location,
previous state, and
temperature sensor value are
provided.
Error
A temperature sensor on the
backplane board, system
board, or drive carrier in the
specified system detected an
error from which it cannot
recover. The sensor location,
chassis location, previous
state, and temperature sensor
value are provided.
Temperature Probe Failure
1054
Temperature sensor detected a
failure value
Sensor location: <Location in chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
If sensor type is not discrete:
Temperature sensor value (in degrees
Celsius): <Reading>
If sensor type is discrete: Discrete
temperature state: <State>
Temperature Probe Nonrecoverable
1055
Temperature sensor detected a
non-recoverable value
Sensor location: <Location in chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
If sensor type is not discrete:
Temperature sensor value (in degrees
Celsius): <Reading>
If sensor type is discrete: Discrete
temperature state: <State>
Traps
575
Cooling Device Traps
Cooling device traps monitor how well a fan is functioning.
Table 25-4.
Cooling Device Traps
Trap ID Description
Severity
Cause
Information
A fan sensor reading on the
specified system returned to a
valid range after crossing a
warning threshold. The sensor
location, chassis location,
previous state, and fan sensor
value are provided.
Warning
A fan sensor reading in the
specified system exceeded a
warning threshold. The sensor
location, chassis location,
previous state, and fan sensor
value are provided.
Error
A fan sensor in the specified
system detected the failure of
one or more fans. The sensor
location, chassis location,
previous state, and fan sensor
value are provided.
Error
A fan sensor detected an error
from which it cannot recover.
The sensor location, chassis
location, previous state, and
fan sensor value are provided.
Cooling Device Normal
1102
Fan sensor returned to a normal value
Sensor location: <Location in chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
Fan sensor value: <Reading>
Cooling Device Warning
1103
Fan sensor detected a warning value
Sensor location: <Location in chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
Fan sensor value: <Reading>
Cooling Device Failure
1104
Fan sensor detected a failure value
Sensor location: <Location in chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
Fan sensor value: <Reading>
Cooling Device Nonrecoverable
1105
Fan sensor detected a non-recoverable
value
Sensor location: <Location in chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
Fan sensor value: <Reading>
576
Traps
Voltage Probe Traps
Voltage probes monitor the number of volts across critical components.
Table 25-5.
Voltage Probe Traps
Trap ID Description
Severity
Cause
Information
A voltage sensor in the specified
system returned to a valid range
after crossing a failure threshold.
The sensor location, chassis
location, previous state, and voltage
sensor value are provided.
Warning
A voltage sensor in the specified
system exceeded its warning
threshold. The sensor location,
chassis location, previous state, and
voltage sensor value are provided.
Voltage Probe Normal
1152
Voltage sensor returned to a
normal value
Sensor location: <Location in
chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
If sensor type is not discrete:
Voltage sensor value (in Volts):
<Reading>
If sensor type is discrete: Discrete
voltage state: <State>
Voltage Probe Warning
1153
Voltage sensor detected a
warning value
Sensor location: <Location in
chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
If sensor type is not discrete:
Voltage sensor value (in Volts):
<Reading>
If sensor type is discrete: Discrete
voltage state: <State>
Traps
577
Table 25-5.
Voltage Probe Traps (continued)
Trap ID Description
Severity
Cause
Error
A voltage sensor in the specified
system exceeded its failure
threshold. The sensor location,
chassis location, previous state, and
voltage sensor value are provided.
Error
A voltage sensor in the specified
system detected an error from
which it cannot recover. The sensor
location, chassis location, previous
state, and voltage sensor value are
provided.
Voltage Probe Failure
1154
Voltage sensor detected a
failure value
Sensor location: <Location in
chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
If sensor type is not discrete:
Voltage sensor value (in Volts):
<Reading>
If sensor type is discrete: Discrete
voltage state: <State>
Voltage Probe Nonrecoverable
1155
Voltage sensor detected a
non-recoverable value
Sensor location: <Location in
chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
If sensor type is not discrete:
Voltage sensor value (in Volts):
<Reading>
If sensor type is discrete: Discrete
voltage state: <State>
578
Traps
Amperage Probe Traps
Amperage probes measure the amount of current (in amperes) that is traversing critical components.
Table 25-6.
Amperage Probe Traps
Trap ID Description
Severity
Cause
Information
A current sensor on the power
supply for the specified system
returned to a valid range after
crossing a failure threshold. The
sensor location, chassis location,
previous state, and current sensor
value are provided.
Warning
A current sensor on the power
supply for the specified system
exceeded its warning threshold.
The sensor location, chassis
location, previous state, and
current sensor value are provided.
Amperage Probe Normal
1202
Current sensor returned to a
normal value
Sensor location: <Location in chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
If sensor type is not discrete:
Current sensor value (in Amps):
<Reading>
If sensor type is discrete: Discrete
current state: <State>
Amperage Probe Warning
1203
Current sensor detected a
warning value
Sensor location: <Location in chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
If sensor type is not discrete:
Current sensor value (in Amps):
<Reading>
If sensor type is discrete: Discrete
current state: <State>
Traps
579
Table 25-6.
Amperage Probe Traps (continued)
Trap ID Description
Severity
Cause
Error
A current sensor on the power
supply for the specified system
exceeded its failure threshold. The
sensor location, chassis location,
previous state, and current sensor
value are provided.
Error
A current sensor in the specified
system detected an error from
which it cannot recover. The sensor
location, chassis location, previous
state, and current sensor value are
provided.
Amperage Probe Failure
1204
Current sensor detected a
failure value
Sensor location: <Location in chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
If sensor type is not discrete:
Current sensor value (in Amps):
<Reading>
If sensor type is discrete: Discrete
current state: <State>
Amperage Probe Nonrecoverable
1205
Current sensor detected a
non-recoverable value
Sensor location: <Location in chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
If sensor type is not discrete:
Current sensor value (in Amps):
<Reading>
If sensor type is discrete: Discrete
current state: <State>
580
Traps
Chassis Intrusion Traps
Chassis intrusion traps are a security measure. Chassis intrusion means that someone is opening the
cover to a system’s chassis. Alerts are sent to prevent unauthorized removal of parts from a chassis.
Table 25-7.
Trap ID
Chassis Intrusion Traps
Description
Severity
Cause
Information
A chassis intrusion sensor in the
specified system detected that a
cover was opened while the system
was operating but has since been
replaced. The sensor location,
chassis location, previous state, and
chassis intrusion state are provided.
Error
A chassis intrusion sensor in the
specified system detected that the
system cover was opened while the
system was operating. The sensor
location, chassis location, previous
state, and chassis intrusion state are
provided.
Chassis Intrusion Normal
1252
Chassis intrusion returned to normal
Sensor location: <Location in chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
Chassis intrusion state: <Intrusion
state>
Chassis Intrusion Detected
1254
Chassis intrusion detected
Sensor location: <Location in chassis>
Chassis location: <Name of chassis>
Previous state was: <State>
Chassis intrusion state: <Intrusion
state>
Redundancy Unit Traps
Redundancy means that a system chassis has more than one of certain critical components. Fans and
power supplies, for example, are so important for preventing damage or disruption of a computer system
that a chassis may have "extra" fans or power supplies installed. Redundancy allows a second or nth fan to
keep the chassis components at a safe temperature when the primary fan has failed. Redundancy is
normal when the intended number of critical components are operating. Redundancy is degraded when
a component fails but others are still operating. Redundancy is lost when the number of components
functioning falls below the redundancy threshold.
The number of devices required for full redundancy is provided as part of the trap message when
applicable for the redundancy unit and the platform. For more details on redundancy computation,
please refer to the respective platform documentation.
Traps
581
Table 25-8.
Trap ID
Redundancy Unit Traps
Description
Severity
Cause
Information
A redundancy sensor in the specified
system detected that a "lost" redundancy
device has been reconnected or
replaced; full redundancy is in effect.
The redundancy unit location, chassis
location, and previous redundancy state
are provided.
Warning
A redundancy sensor in the specified
system detected that one of the
components of the redundancy unit has
failed but the unit is still redundant.
The redundancy unit location, chassis
location, and previous redundancy state
are provided.
Warning or
Error
(depending on
the number of
units that are
functional)
A redundancy sensor in the specified
system detected that one of the
components in the redundant unit has
been disconnected, has failed, or is not
present. The redundancy unit location,
chassis location, and previous
redundancy state are provided.
Redundancy Normal
1304
Redundancy regained
Redundancy unit: <Redundancy
location in chassis>
Chassis location: <Name of
chassis>
Previous redundancy state was:
<State>
Number of devices required for
full redundancy: <Number>
Redundancy Degraded
1305
Redundancy degraded
Redundancy unit: <Redundancy
location in chassis>
Chassis location: <Name of
chassis>
Previous redundancy state was:
<State>
Number of devices required for
full redundancy: <Number>
Redundancy Lost
1306
Redundancy lost
Redundancy unit: <Redundancy
location in chassis>
Chassis location: <Name of
chassis>
Previous redundancy state was:
<State>
Number of devices required for
full redundancy: <Number>
582
Traps
Power Supply Traps
Power supply traps provide status and warning information for power supplies present in a particular chassis.
Table 25-9.
Trap ID
Power Supply Traps
Description
Severity
Cause
Information
A power supply has been reconnected or
replaced. The sensor location, chassis
location, previous state, and additional
information about the power supply
event are provided.
Warning
A power supply sensor has detected a
warning condition. The sensor location,
chassis location, previous state, and
additional power supply status
information are provided.
Power Supply Normal
1352
Power supply returned to normal
Sensor location: <Location in
chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
Power Supply type: <type of
power supply>
<Additional power supply status
information>
If in configuration error state:
Configuration error type: <type
of configuration error>
Power Supply Warning
1353
Power supply detected a warning
Sensor location: <Location in
chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
Power Supply type: <type of
power supply>
<Additional power supply status
information>
If in configuration error state:
Configuration error type: <type
of configuration error>
Traps
583
Table 25-9.
Trap ID
Power Supply Traps (continued)
Description
Severity
Cause
Error
A power supply has been disconnected
or has failed. The sensor location,
chassis location, previous state, and
additional information about the power
supply event are provided.
Power Supply Failure
1354
Power supply detected a failure
Sensor location: <Location in
chassis>
Chassis location: <Name of
chassis>
Previous state was: <State>
Power Supply type: <type of
power supply>
<Additional power supply status
information>
If in configuration error state:
Configuration error type: <type
of configuration error>
Memory Device Traps
Memory device messages provide status and warning information for memory modules present in a
particular system. Memory devices determine health status by counting the number of ECC memory
corrections.
NOTE: A value of failure or non-recoverable does not indicate a system failure or loss of data, but rather
that the specified system exceeded the specified ECC correction threshold. Although the system continues to
function, you should perform system maintenance as described in Table 25-10.
Table 25-10. Memory Device Messages
Trap ID
1403
Description
Memory device status is <status> Warning
Memory device location:
<Location in chassis>
Possible memory module event
cause: <list of causes>
584
Severity
Traps
Cause
A memory device correction rate
exceeded an acceptable value. The
memory device status and location are
provided.
Table 25-10. Memory Device Messages (continued)
Trap ID
Description
Severity
1404
Memory device status is <Status> Error
Memory device location:
<Location in chassis>
Possible memory module event
cause: <list of causes>
Cause
A memory device correction rate
exceeded an acceptable value, a memory
spare bank was activated, or a
Uncorrectable Memory Event occurred.
The system continues to function
normally (except for a Uncorrectable
Memory Event). Clear the memory
error on Uncorrectable Memory Event.
Replace the memory module identified
in the message during the system’s next
scheduled maintenance. The memory
device status and location are provided.
Fan Enclosure Traps
Some systems are equipped with a protective enclosure for fans. Fan enclosure traps monitor enclosures
for whether foreign objects are present and for how long a fan enclosure is absent from a chassis.
Table 25-11. Fan Enclosure Traps
Trap ID Description
Severity
Cause
Fan Enclosure Insertion
1452
Fan enclosure inserted into system Information
Sensor location: <Location in
chassis>
Chassis location: <Name of
chassis>
A fan enclosure has been inserted into
the specified system. The sensor
location and chassis location are
provided.
Fan Enclosure Removal
1453
Fan enclosure removed from system Warning
Sensor location: <Location in
chassis>
Chassis location: <Name of
chassis>
A fan enclosure has been removed from
the specified system. The sensor
location and chassis location are
provided.
Fan Enclosure Extended Removal
1454
Fan enclosure removed from system Error
for an extended amount of time
Sensor location:
<Location in chassis>
A fan enclosure has been removed from
the specified system for a user-definable
length of time. The sensor location and
chassis location are provided.
Chassis location: <Name of chassis>
Traps
585
AC Power Cord Traps
The AC power cord sensor monitors the presence of AC power for an AC power cord. AC power cord
traps provide status and warning information for power cords that are part of an AC power switch, if your
system supports AC switching.
Table 25-12. AC Power Cord Traps
Trap ID
Description
Severity
Cause
Information
The AC power cord status is not being
monitored. This occurs when a system’s
expected AC power configuration is set
to nonredundant. The sensor location
and chassis location information are
provided.
Information
An AC power cord that did not have
AC power has had the power restored.
The sensor location and chassis location
information are provided.
Error
An AC power cord has lost its power.
The sensor location and chassis location
information are provided.
AC Power Cord No Power Nonredundant
1501
AC power cord is not being
monitored
Sensor location: <Location in
chassis>
Chassis location: <Name of chassis>
AC Power Cord Normal
1502
AC power has been restored
Sensor location: <Location in
chassis>
Chassis location: <Name of chassis>
AC Power Cord Failure
1504
AC power has been lost
Sensor location: <Location in
chassis>
Chassis location: <Name of chassis>
586
Traps
Hardware Log Traps
Hardware logs provide hardware status messages to systems management software. On certain systems,
the hardware log is implemented as a circular queue. When the log becomes full, the oldest status
messages are overwritten when new status messages are logged. On some systems, the log is not circular.
On these systems, when the log becomes full, subsequent hardware status messages are lost. Hardware
log sensor messages provide status and warning information about the noncircular logs that may fill up,
resulting in lost status messages.
Table 25-13. Hardware Log Traps
Trap ID
Description
Severity
Cause
Information
The hardware log on the specified
system is no longer near or at its
capacity, usually as the result of
clearing the log. The log type
information is provided.
Warning
The size of a hardware log on the
specified system is near or at the
capacity of the hardware log. The log
type information is provided.
Error
The size of a hardware log on the
specified system is at the capacity of
the hardware log. The log type
information is provided.
Hardware Log Normal
1552
Log size is no longer near or
at capacity
Log type: <Log type>
Hardware Log Warning
1553
Log size is near or at capacity
Log type: <Log type>
Hardware Log Full
1554
Log size is full
Log type: <Log type>
Traps
587
Processor Device Status Traps
The BMC on some systems reports the status of processor devices. Processor device status traps provide
status and warning information for processor devices present in a system with a BMC that reports the
status of processor devices.
Table 25-14. Processor Device Status Traps
Trap ID
Description
Severity
Cause
Information
A processor sensor in the specified
system transitioned back to a normal
state. The sensor location, chassis
location, previous state and processor
sensor status are provided.
Warning
A processor sensor in the specified
system is in a throttled state. The
sensor location, chassis location,
previous state and processor sensor
status are provided.
Error
A processor sensor in the specified
system is disabled, has a configuration
error, or experienced a thermal trip.
The sensor location, chassis location,
previous state and processor sensor
status are provided.
Processor Device Status Normal
1602
Processor sensor returned to a
normal value
Sensor Location: <Location in
chassis>
Chassis Location: <Name of
chassis>
Previous state was: <State>
Processor sensor status: <status>
Processor Device Status Warning
1603
Processor sensor detected a
warning value
Sensor Location: <Location in
chassis>
Chassis Location: <Name of chassis>
Previous state was: <State>
Processor sensor status: <status>
Processor Device Status Failure
1604
Processor sensor detected a
failure value
Sensor Location: <Location in
chassis>
Chassis Location: <Name of chassis>
Previous state was: <State>
Processor sensor status: <status>
588
Traps
Pluggable Device Traps
Server Administrator monitors the addition and removal of pluggable devices such as memory cards.
Device traps provide information about the addition and removal of such devices.
Table 25-15. Pluggable Device Traps
Trap ID
Description
Severity
Cause
Information
A device was added to the specified
system. The device location, chassis
location, and additional event details, if
available, are provided.
Information
A device was removed from the
specified system. The device location,
chassis location, and additional event
details, if available, are provided.
Error
A configuration error was detected for a
pluggable device in the specified
system. The device may have been
added to the system incorrectly. The
device location, chassis location, and
additional event details, if available, are
provided.
Pluggable Device Addition
1651
Device added to system
Device Location: <Location in
chassis>
Chassis Location: <Name of chassis>
Additional Details: <Additional
details for the events>
Pluggable Device Removal
1652
Device removed from system
Device Location: <Location in
chassis>
Chassis Location: <Name of chassis>
Additional Details: <Additional
details for the events>
Pluggable Device Configuration Error
1653
Device configuration error detected
Device Location: <Location in
chassis>
Chassis Location: <Name of chassis>
Additional Details: <Additional
details for the events>
Traps
589
Battery Traps
The BMC on some systems reports the status of batteries. Battery traps provide status and warning
information for batteries present in a system with a BMC that reports the status of batteries.
Table 25-16. Battery Traps
Trap ID
Description
Severity
Cause
Informational
A battery sensor in the specified system
detected that a battery transitioned
back to a normal state. The sensor
location, chassis location, previous
state, and battery sensor status are
provided.
Battery Normal
1702
Battery sensor returned to a
normal value
Sensor Location: <Location in
chassis>
Chassis Location: <Name of
chassis>
Previous state was: <State>
Battery sensor status: <status>
Battery Warning
1703
Battery sensor detected a warning Warning
value
Sensor Location: <Location in
chassis>
Chassis Location: <Name of
chassis>
A battery sensor in the specified system
detected that a battery is in a predictive
failure state. The sensor location,
chassis location, previous state, and
battery sensor status are provided.
Previous state was: <State>
Battery sensor status: <status>
Battery Failure
1704
Battery sensor detected a failure Critical
value
Sensor Location: <Location in
chassis>
Chassis Location: <Name of
chassis>
Previous state was: <State>
Battery sensor status: <status>
590
Traps
A battery sensor in the specified system
detected that a battery has failed. The
sensor location, chassis location,
previous state, and battery sensor
status are provided.
RAC Traps
This section describes the traps that are generated by the SNMP agent of the Remote Access Controller (RAC).
All of the enterprise-specific traps documented in this section belong to the MIB enterprise identified by
OID 1.3.6.1.4.1.674.10892.2 and are sent with all of the trap variables documented in the section “Traps”.
The trap variables are sent in the order in which they are listed.
Table 25-17. Generic Traps
Trap ID Name
Description
Severity
Category Cause
Supported by
RAC Platform
0
CodeStart
SNMP agent is
initializing
itself
Information
Status
RAC power on or reset. All
1
Authentication Request received
Failure
with an invalid
community name
Critical
Error
SNMP request with an All
invalid community
name.
Severity
Category Cause
Supported by
RAC Platform
All
Table 25-18. Enterprise-specific Traps
Trap ID Name
Description
1001
alertDrscTest
TrapEvent
The RAC generated Information
a test trap event
in response to a
user request
Status
A test SNMP trap
generated by a RAC.
1002
alertDrscAuth
Error
RAC
Minor
Authentication
failures during a
time period have
exceeded a
threshold
Error
RAC login failure
All
caused by
authentication failure,
number of concurrent
logins exceed limit, or
permission denied.
1003
alertDrscLost
ESM
The RAC cannot
communicate with
the baseboard
management
controller (ESM)
Error
RAC lost
communication with
ESM.
Dell™
Remote
Access
Controller
(DRAC) III
1004
alertDrscFound The RAC is
Information
ESM
communicating
normally with the
baseboard
management
controller (ESM)
Error
RAC recovered
communication with
ESM.
DRAC III
Critical
Traps
591
Table 25-18. Enterprise-specific Traps (continued)
Trap ID Name
592
Description
Severity
Category Cause
Supported by
RAC Platform
1005
alertDrscPower The RAC has
Critical
Off
detected a system
power state
change to
powered-off
Error
RAC detected a system DRAC III
power state change to
power-off.
1006
alertDrscPower The RAC has
Information
On
detected a system
power state
change to
powered-on
Error
RAC detected a system DRAC III
power state change to
power-on.
1007
alertDrsc
Watchdog
Expired
The RAC has
Critical
detected that the
system watchdog
has expired
indicating a
system hang
Event
RAC has detected the
system watchdog
expired (normally
indicating a system
hang).
1008
alertDrscBatt
Low
The RAC Battery
Minor
charge is below
25% indicating
that the battery
may only be able
to power the DRSC
for 8-10 minutes
Error
RAC detected its
DRAC III
battery charge is below
25% full.
1009
Information
alertDrscTemp The RAC
Normal
Temperature probe
has returned to a
normal value
Status
DRAC III
RAC temperature
probe reading returned
to normal.
1010
alertDrscTemp The RAC
Minor
Warning
Temperature probe
has detected a
Warning value
Status
DRAC III
RAC temperature
probe reading exceeded
warning threshold.
1011
Critical
alertDrscTemp The RAC
Critical
Temperature probe
has detected a
failure (or
critical) value
Error
RAC temperature
DRAC III
probe reading exceeded
critical threshold.
1012
alertDrscVolt
Normal
Error
RAC voltage probe
reading returns to
normal.
Traps
The RAC voltage
Information
has returned to a
normal value
DRAC III
DRAC III
Table 25-18. Enterprise-specific Traps (continued)
Trap ID Name
Description
Severity
Category Cause
Supported by
RAC Platform
1013
alertDrscVolt
Warning
The RAC voltage
probe has
detected a
warning value
Minor
Error
RAC voltage probe
reading exceeded
warning threshold.
DRAC III
1014
alertDrscVolt
Critical
The RAC voltage
probe has
detected a
failure (or
critical) value
Critical
Error
RAC voltage probe
reading exceeded
critical threshold.
DRAC III
1015
alertDrscSEL
Warning
The RAC has
detected a new
event in the
System Event Log
with Severity:
Warning
Major
Error
RAC detected a new
system event log with
warning severity
(detailed log info is in
drsAlert
Message varbind).
All
1016
alertDrscSEL
Critical
The RAC has
detected a new
event in the
System Event Log
with Severity:
Critical
Critical
Error
RAC detected a new
system event log with
critical severity
(detailed log info is in
drsAlert
Message varbind).
All
1017
alertDrscSEL The RAC system
80
event log is 80%
percentFull
full
Major
Status
RAC detected system
event log is 80% full.
All
1018
alertDrscSEL The RAC system
event log is 90%
90
full
percentFull
Major
Status
RAC detected system
event log is 90% full.
All
1019
alertDrscSEL The RAC system
Major
100
event log is 100%
percentFull
full
Status
RAC detected system
event log is 100% full.
All
1020
alertDrscSEL
Normal
Error
RAC detected a new
system event log with
normal severity
(detailed log info is in
drsAlert
Message varbind).
All
The RAC has
detected a new
event in the
System Event Log
with Severity:
Normal
Information
Traps
593
BMC Traps
The BMC monitors the system for critical events by communicating with various sensors on the system
board and by sending alerts and log events when certain parameters exceed their preset thresholds. All of
the traps documented in this section belong to the MIB enterprise identified by OID
1.3.6.1.4.1.3183.1.1.1.
Table 25-19. BMC Traps
594
Trap ID
Description
Severity
262402
Generic Critical Fan Failure
Critical
262530
Generic Critical Fan Failure Cleared
Informational
131330
Under-Voltage Problem (Lower Critical - going low)
Critical
131458
Under-Voltage Problem Cleared
Informational
131841
Generic Critical Voltage Problem
Critical
131840
Generic Critical Voltage Problem Cleared
Informational
65792
Under-Temperature Warning (Lower non-critical, going low)
Warning
65920
Under-Temperature Warning Cleared
Informational
65794
Under-Temperature Problem (Lower Critical - going low)
Critical
65922
Under-Temperature Problem Cleared
Informational
65799
Over-Temperature warning (Upper non-critical, going high)
Minor
65927
Over-Temperature warning Cleared
Informational
65801
Over-Temperature Problem (Upper Critical - going high)
Critical
65929
Over-Temperature Problem Cleared
Informational
131328
Under-Voltage Warning (Lower Non Critical - going low)
Warning
131456
Under-Voltage Warning Cleared
Informational
131330
Under-Voltage Problem (Lower Critical - going low)
Critical
131458
Under-Voltage Problem Cleared
Informational
131335
Over-Voltage Warning (Upper Non Critical - going high)
Warning
131463
Over-Voltage Warning Cleared
Informational
131337
Over-Voltage Problem (Upper Critical - going high)
Critical
131465
Over-Voltage Problem Cleared
Informational
131841
Generic Critical Voltage Problem
Critical
131840
Generic Critical Voltage Problem Cleared
Informational
356096
Chassis Intrusion - Physical Security Violation
Critical
Traps
Table 25-19. BMC Traps (continued)
Trap ID
Description
Severity
356224
Chassis Intrusion (Physical Security Violation) Event Cleared Informational
262400
Generic Predictive Fan Failure (predictive failure asserted) Minor
262528
Generic Predictive Fan Failure Cleared
Informational
262402
Generic Critical Fan Failure
Critical
262530
Generic Critical Fan Failure Cleared
Informational
264962
Fan redundancy has been degraded
Warning
264961
Fan Redundancy Lost
Critical
264960
Fan redundancy Has Returned to Normal
Informational
2715392 Battery Low (Predictive Failure)
Warning
2715520 Battery Low (Predictive Failure) Cleared
Informational
2715393 Battery Failure
Critical
2715521 Battery Failure Cleared
Informational
487169
CPU Thermal Trip (Over Temperature Shutdown)
Critical
487297
CPU Thermal Trip (Over Temperature Shutdown) Cleared
Informational
487168
CPU Internal Error
Critical
487296
CPU Internal Error Cleared
Informational
487173
CPU Configuration Error
Critical
487301
CPU Configuration Error Cleared
Informational
487175
CPU Presence (Processor Presence detected)
Informational
487303
CPU Not Present (Processor Not Present)
Critical
487170
CPU BIST (Built In Self Test) Failure
Critical
487298
CPU BIST (Built In Self Test) Failure Cleared
Informational
487176
CPU Disabled (Processor Disabled)
Critical
487304
CPU Enabled (Processor Enabled)
Informational
487178
CPU Throttle (Processor Speed Reduced)
Warning
487306
CPU Throttle Cleared (Normal Processor Speed)
Informational
527106
Power Supply Redundancy Degraded
Warning
527105
Power Supply Redundancy Lost
Critical
527104
Power Supply Redundancy Has Returned to Normal
Informational
552704
Power Supply Inserted
Informational
Traps
595
Table 25-19. BMC Traps (continued)
596
Trap ID
Description
Severity
552832
Power Supply Removed
Warning
552705
Power Supply Failure
Critical
552833
Power Supply Failure Cleared
Informational
552706
Power Supply Warning
Warning
552834
Power Supply Warning Cleared
Informational
552707
Power Supply AC Lost
Critical
552835
Power Supply AC Restored
Informational
789249
Memory Redundancy Has Been Lost
Critical
789248
Memory redundancy Has Returned to Normal
Informational
1076994 System Event Log (SEL) Cleared
Informational
1076996 System Event Log (SEL) Full (Logging Disabled)
Critical
2322176 ASR (Automatic System Recovery) Timer Expired
Critical
2322177 ASR (Automatic System Recovery) Reset Occurred
Critical
2322178 ASR (Automatic System Recovery) Power Down Occurred
Critical
2322179 ASR (Automatic System Recovery) Power Cycle Occurred
Critical
Traps
Storage Management Alert Reference
Storage Management’s alert or event management features let you monitor the health of storage
resources such as controllers, connectors, array disks, and virtual disks.
Alert Monitoring and Logging
The Storage Management Service performs alert monitoring and logging. By default, the Storage
Management Service starts when the managed system starts up. If you stop the Disk Management
Service, then alert monitoring and logging stops. Alert monitoring does the following:
•
Updates the status of the storage object that generated the alert.
•
Propagates the storage object’s status to all the related higher objects in the storage hierarchy.
For example, the status of a lower-level object will be propagated up to the status displayed on the
Health tab for the top-level storage object.
•
Logs an alert into the Alert log and Microsoft® Windows® application log.
•
Sends an Simple Network Management Protocol (SNMP) trap if the operating system’s SNMP
service is installed and enabled.
NOTE: Storage Management does not log alerts regarding the data I/O path. These alerts are logged by the
respective RAID drivers in the system alert log.
Viewing Alerts
Storage Management generates alerts that are added to the Windows application alert log and to the
Server Administrator Alert log. To view these alerts in Server Administrator:
1 Select the System object in the tree view.
2 Select the Logs tab.
3 Select the Alert subtab.
NOTE: You can also view these alerts in the Windows Event Viewer. Every alert consists of the following:
•
Severity — Shows the severity of alert.
•
Date and Time — Date and time when Storage Management logged the alert.
•
Description — A brief description of the alert. To expand or collapse the alert description, click the
Description column heading.
Storage Management Alert Reference
597
Alert Severity Levels
Each alert message in the Storage Management alert log has a severity level. The severity level is
displayed in the Severity field of the alert message. The severity level indicates the nature of the alert.
The alert severity levels are as follows:
Table 26-1.
Storage Management Alert Severity
Alert Severity
Component Status
OK/Normal/Informational
No action is required. The alert is provided for informational purposes and does
not indicate an error condition. For example, the alert may indicate the normal
start or stop of an operation.
Warning/Non-critical
A component requires attention. This alert indicates a potential problem, but
does not necessarily mean that the system has currently lost data or is
nonfunctional. For example, a Warning/Non-critical alert may indicate that a
component (such as a temperature probe in an enclosure) has crossed a
warning threshold.
Critical/Failure/Error
A component has either failed or failure is imminent. This alert indicates a
serious problem such as data loss or a loss of function. For example, a
Critical/Failure/Error alert may indicate that an array disk has failed.
SNMP Support for Storage Management Alerts
By default, Storage Management installs SNMP trap forwarding support. For this support to function,
you should have SNMP installed on the managed system prior to installing Storage Management.
NOTE: For more information on installation requirements and SNMP, see the Server Administrator documentation.
SNMP Trap Forwarding
The Storage Management alerts are displayed in the Server Administrator alert log and are forwarded to
the Windows application alert log. If you have SNMP installed on the managed system (and the
SNMP service is running), the Storage Management alerts in the Windows application alert log will be
forwarded as SNMP traps. In order for these traps to be viewable, however, a target system or application
must be configured to receive these traps. SNMP traps that are generated by Storage Management can
be viewed in any standard SNMP-compatible enterprise management console.
The Windows SNMP service must be configured to forward the SNMP traps to the target system or
application. When forwarding to an application, the application should also be configured to receive the
SNMP traps. The IT Assistant application is already configured to receive the SNMP traps generated by
Storage Management.
598
Storage Management Alert Reference
See your Windows operating system documentation for information on configuring the operating system
to forward SNMP traps. This information may be located under such topics as “setting up SNMP” or
“SNMP traps.” When configuring SNMP for Windows, be sure that the SNMP traps are forwarded to
the correct server. For information on configuring an application to receive SNMP traps, see the
documentation for that application.
SNMP Trap Definitions
The Storage Management management information base (MIB) defines the SNMP traps that Storage
Management generates. These traps correspond to the alerts documented in the “Alert Descriptions and
Corrective Actions" section. The MIB is located in ..\sm\mibs\dcstorag.mib, a subdirectory of the Storage
Management installation directory.
NOTE: Storage Management supports trap forwarding on both 32-bit and 64-bit operating systems.
SNMP Trap Variables
The Storage Management SNMP traps use a set of variables that are included with every trap.
These variables are the following:
•
messageIDEvent
•
descriptionEvent
•
locationEvent
•
objectNameEvent
•
objectOIDEvent
•
objectNexusEvent
•
currentStatusEvent
•
previousStatusEvent
Viewing SNMP Traps
SNMP traps that are generated by Storage Management can be viewed in any standard SNMP-compatible
enterprise management console. These traps are defined in the Storage Management MIB. These traps
correspond to the alerts documented in the “Alert Descriptions and Corrective Actions” section.
For more information on the MIB and its structure, as well as a change history of the SNMP traps, see
the "Introduction" section. For more information on configuring SNMP, see "SNMP Support for Storage
Management Alerts."
Storage Management Alert Reference
599
Alert Descriptions and Corrective Actions
The alerts generated by the redundant array of independent disks (RAID) or Small Computer System
Interface (SCSI) controllers and supported by Storage Management are displayed in the Server
Administrator Alert subtab or through Windows Event Viewer. These alerts can also be forwarded as
SNMP traps to other applications.
SNMP traps are generated for the alerts are included in the Storage Management MIB. The SNMP traps
for these alerts use all of the SNMP trap variables. For the list of storage management alerts and storage
management messages, see the Dell OpenManage Server Administrator Messages Reference Guide.
This guide is available on the Dell Support website at support.dell.com and on the Dell PowerEdge
Documentation CD.
600
Storage Management Alert Reference
Standard Data Type Definitions
This appendix contains definitions for data types that are standard in most contexts across the
information technology industry. These are the most common data types for expressing variable
values defined in the 10892.mib, dcs3rmt.mib and dcs3fru.mib files. Server Administrator-specific
variable values are defined in the last section of the section in which they are introduced.
Common Data Types
Common data types include several types of strings, the object range, signed and unsigned bit
ranges, and the familiar Boolean (true or false) data type.
Table A-1. Common Data Types
Variable Name:
Definition
DellString
DisplayString (SIZE (0..64))
DellSecurityString
DisplayString (SIZE (0..255))
DellCostofOwnershipString
DisplayString (SIZE (0..64))
DellObjectRange
INTEGER (1..128)
DellUnsigned8BitRange
INTEGER (1..256)
DellUnsigned16BitRange
INTEGER (1..65535)
DellUnsigned32BitRange
INTEGER (1..2147483647)
DellSigned32BitRange
INTEGER (-2147483647..2147483647)
DellBoolean
INTEGER (0..1 (FALSE = 0, TRUE = 1))
Standard Data Type Definitions
601
Variables with Data Types of State Capabilities and
State Capabilities Unique
Variables with definitions of <variable name>StateCapabilities or <variable
name>StateCapabilitiesUnique are integers representing a series of bit definitions. They are
NOT enumerations and should be treated as bit fields. The value is passed as a decimal value. The decimal
value should be converted to hex and the appropriate bits should be parsed from hex. Some of the more
common bit combinations are defined in some variables, but not all combinations are or will be defined.
Table A-2.
Dell State Capabilities
Variable Name: DellStateCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
if set to zero(0)
The object has no capabilities.
unknownCapabilities(1)
The object’s capabilities are unknown.
enableCapable(2)
The object can be disabled (offline, a binary 0 value) or
enabled (online, a binary 1 value).
notReadyCapable(4)
The object is not ready.
enableAndNotReadyCapable(6)
Enable and not ready capable.
Table A-3.
Dell State Settings
Variable Name: DellStateSettings
Data Type: Integer
602
Possible Data Values
Meaning of Data Value
if set to zero(0)
The object has no settings capabilities and its state is
disabled.
unknown(1)
The object’s state is unknown.
enabled(2)
The object’s state is disabled (offline, a binary 0 value) or
enabled (online, a binary 1 value).
notReady(4)
The object is not ready.
enableAndNotReady(6)
The object is enabled and not ready.
Standard Data Type Definitions
Table A-4.
Dell Probe Capabilities
Variable Name: DellProbeCapabilities
Data Type: Integer
Possible Data Values
Meaning of Data Value
if set to zero(0)
The object has no capabilities.
upperNonCriticalThresholdSetCapable(1)
The upper noncritical threshold can be set.
lowerNonCriticalThresholdSetCapable(2)
The lower noncritical threshold can be set.
upperNonCriticalThresholdDefaultCapable(4) The upper noncritical threshold can be set to default.
lowerNonCriticalThresholdDefaultCapable(8) The lower noncritical threshold can be set to default.
Dell Status Data Types
Status data types include DellStatus, DellStatusRedundancy, and DellStatusProbe.
Table A-5.
Dell Status
Variable Name: DellStatus
Data Type: Integer
Possible Data Values
Meaning of Data Value
other(1)
The object’s status is not one of the following:
unknown(2)
The object’s status is unknown.
ok(3)
The object’s status is OK.
nonCritical(4)
The object’s status is warning, noncritical.
critical(5)
The object’s status is critical (failure).
nonRecoverable(6)
The object’s status is nonrecoverable (dead).
Standard Data Type Definitions
603
Table A-6.
Dell Status Redundancy
Variable Name: DellStatusRedundancy
Data Type: Integer
Possible Data Values
Meaning of Data Value
other(1)
The object’s status is not one of the following:
unknown(2)
The object’s redundancy status is unknown.
full(3)
The object is fully redundant.
degraded(4)
The object’s redundancy has been degraded.
lost(5)
The object’s redundancy has been lost.
notRedundant(6)
Redundancy does not apply or it is not redundant.
Table A-7.
Dell Status Probe
Variable Name: DellStatusProbe
Data Type: Integer
604
Possible Data Values
Meaning of Data Value
other(1)
The object’s status is not one of the following:
unknown(2)
The status of the object is unknown.
ok(3)
The status of the object is OK.
nonCriticalUpper(4)
The object is at the noncritical upper limit.
CriticalUpper(5)
The object is at the critical upper limit.
nonRecoverableUpper(6)
The object is at the nonrecoverable upper limit.
nonCriticalLower(7)
The object is at the noncritical lower limit.
criticalLower(8)
The object is at the critical lower limit.
nonRecoverableLower(9)
The object is at the nonrecoverable lower limit.
failed(10)
The status of the object is failed.
Standard Data Type Definitions
Dell Date
Variable Name: DellDate
Data Type: DellUnsigned64BitRange
OCTET STRING (SIZE(8))
The DellDate definition is required because SNMP V1 does not support 64-bit ranges. The information
sent back by this subagent will have the most significant byte of the information as the first byte. For
example, the hex address 0x1029384754657687 will be sent as hex: 0001 0000 0010 1001 0011 1000 0100
0111 ... Byte 1 Byte 2 Byte 3 Byte 4.
Full Dates
Variable Name: DellDateName
Data Type: DisplayString
DisplayString (SIZE (25))
Full dates are defined in the ASCII format:
yyyyMMddhhmmss.uuuuuu+fff or yyyyMMddhhmmss.uuuuuu-fff
where yyyy is the year, MM is the month, dd is the day, hh are the hours, mm are the minutes, and ss are
the seconds. uuuuuu is the number of microseconds, and +fff or
-fff is the offset from UTC in minutes. For example, Friday, October 31, 2001, at 6:05:19 PM CST would
be represented as 20011031180519.000000-360.
The values are zero-padded, and if a valid value for a field is not deliverable, each character in the field
will be replaced with an asterisk (*) character.
Standard Data Type Definitions
605
606
Standard Data Type Definitions
SNMP Sample Output
This sample output from the Simple Network Management Protocol (SNMP) covers the first four
groups of the Instrumentation management information base (MIB). Values are shown for each
object identifier (OID) in the Instrumentation MIB Version Group, the Systems Management
Software Group, the System State Group, the Chassis Information Table, and Event Log Table. The
data is from a Dell™ PowerEdge™ 2650 system.
Walk
.1.3.6.1.4.1.674.10892
(Agent: 'SERVER01',
Community: 'public')
.iso.org.dod.internet.private.enterprises.dell.server3
1.3.6.1.4.1.674.10892.1.1.1.0
=
5
1.3.6.1.4.1.674.10892.1.1.2.0
=
3
1.3.6.1.4.1.674.10892.1.1.3.0
=
0
1.3.6.1.4.1.674.10892.1.100.1.0
=
'Server Administrator'
1.3.6.1.4.1.674.10892.1.100.2.0
=
'5.3.0'
1.3.6.1.4.1.674.10892.1.100.3.0
=
4522
1.3.6.1.4.1.674.10892.1.100.4.0
Dell systems.'
=
'Management software for
1.3.6.1.4.1.674.10892.1.100.5.0
=
1
1.3.6.1.4.1.674.10892.1.100.6.0
=
1
1.3.6.1.4.1.674.10892.1.100.7.0
=
'No Updates'
1.3.6.1.4.1.674.10892.1.100.8.0
=
'https://1.2.3.4:1311'
1.3.6.1.4.1.674.10892.1.100.9.0
=
'en_US'
1.3.6.1.4.1.674.10892.1.100.10.0
=
'2.2.0'
1.3.6.1.4.1.674.10892.1.100.11.0
=
0
1.3.6.1.4.1.674.10892.1.100.12.0
=
1
1.3.6.1.4.1.674.10892.1.100.13.0
=
'Dell Inc.'
SNMP Sample Output
607
1.3.6.1.4.1.674.10892.1.200.10.1.1.1
=
1
1.3.6.1.4.1.674.10892.1.200.10.1.2.1
=
3
1.3.6.1.4.1.674.10892.1.200.10.1.3.1
=
2
1.3.6.1.4.1.674.10892.1.200.10.1.4.1
=
3
1.3.6.1.4.1.674.10892.1.200.10.1.5.1
=
'\02'
1.3.6.1.4.1.674.10892.1.200.10.1.6.1
=
3
1.3.6.1.4.1.674.10892.1.200.10.1.7.1
=
'\03'
1.3.6.1.4.1.674.10892.1.200.10.1.8.1
=
'\02\02'
1.3.6.1.4.1.674.10892.1.200.10.1.9.1
=
3
1.3.6.1.4.1.674.10892.1.200.10.1.10.1
=
'\03\03'
1.3.6.1.4.1.674.10892.1.200.10.1.11.1 =
'\02\02\02\02\02\02\02\02\02\02\02\02\02\02\02\02\02\02\02\02'
1.3.6.1.4.1.674.10892.1.200.10.1.12.1
=
3
1.3.6.1.4.1.674.10892.1.200.10.1.13.1 =
'\03\03\03\03\03\03\03\03\03\03\03\03\03\03\03\03\03\03\03\03'
608
1.3.6.1.4.1.674.10892.1.200.10.1.20.1
=
'\02\02\02\02\02'
1.3.6.1.4.1.674.10892.1.200.10.1.21.1
=
3
1.3.6.1.4.1.674.10892.1.200.10.1.22.1
=
'\03\03\03\03\03'
1.3.6.1.4.1.674.10892.1.200.10.1.23.1
=
'\02\02\02\02\02\02'
1.3.6.1.4.1.674.10892.1.200.10.1.24.1
=
3
1.3.6.1.4.1.674.10892.1.200.10.1.25.1
=
'\03\03\03\03\03\03'
1.3.6.1.4.1.674.10892.1.200.10.1.26.1
=
'\02\02\02\02'
1.3.6.1.4.1.674.10892.1.200.10.1.27.1
=
3
1.3.6.1.4.1.674.10892.1.200.10.1.28.1
=
'\03\03\03\03'
1.3.6.1.4.1.674.10892.1.200.10.1.29.1
=
'\02'
1.3.6.1.4.1.674.10892.1.200.10.1.30.1
=
3
1.3.6.1.4.1.674.10892.1.200.10.1.31.1
=
'\03'
1.3.6.1.4.1.674.10892.1.200.10.1.41.1
=
3
1.3.6.1.4.1.674.10892.1.200.10.1.42.1
=
3
1.3.6.1.4.1.674.10892.1.200.10.1.43.1
=
'\03'
SNMP Sample Output
1.3.6.1.4.1.674.10892.1.300.10.1.1.1
=
1
1.3.6.1.4.1.674.10892.1.300.10.1.2.1
=
0
1.3.6.1.4.1.674.10892.1.300.10.1.3.1
=
2
1.3.6.1.4.1.674.10892.1.300.10.1.4.1
=
3
1.3.6.1.4.1.674.10892.1.300.10.1.5.1
=
0
1.3.6.1.4.1.674.10892.1.300.10.1.6.1
=
23
1.3.6.1.4.1.674.10892.1.300.10.1.7.1
=
'Main System Chassis'
1.3.6.1.4.1.674.10892.1.300.10.1.8.1
=
'Dell Inc.'
1.3.6.1.4.1.674.10892.1.300.10.1.9.1
=
'PowerEdge 2650'
1.3.6.1.4.1.674.10892.1.300.10.1.10.1
=
'ASSETTAG'
1.3.6.1.4.1.674.10892.1.300.10.1.11.1
=
'1234567'
1.3.6.1.4.1.674.10892.1.300.10.1.12.1
=
254
1.3.6.1.4.1.674.10892.1.300.10.1.13.1
=
289
1.3.6.1.4.1.674.10892.1.300.10.1.14.1
=
4
1.3.6.1.4.1.674.10892.1.300.10.1.15.1
=
'SERVER01'
1.3.6.1.4.1.674.10892.1.300.10.1.16.1
=
'20050513095213.000000-360'
1.3.6.1.4.1.674.10892.1.300.10.1.17.1
=
'20050513100052.000000-360'
1.3.6.1.4.1.674.10892.1.300.10.1.18.1
=
'Please set the value'
1.3.6.1.4.1.674.10892.1.300.10.1.19.1
=
'Please set the value'
1.3.6.1.4.1.674.10892.1.300.10.1.20.1
=
'Please set the value'
1.3.6.1.4.1.674.10892.1.300.10.1.21.1
=
3
1.3.6.1.4.1.674.10892.1.300.10.1.22.1
=
0
1.3.6.1.4.1.674.10892.1.300.10.1.23.1
=
0
1.3.6.1.4.1.674.10892.1.300.10.1.24.1
=
0
1.3.6.1.4.1.674.10892.1.300.10.1.25.1
=
0
1.3.6.1.4.1.674.10892.1.300.10.1.26.1
=
0
1.3.6.1.4.1.674.10892.1.300.10.1.27.1
=
0
1.3.6.1.4.1.674.10892.1.300.10.1.28.1
=
8
1.3.6.1.4.1.674.10892.1.300.10.1.29.1
=
2
SNMP Sample Output
609
610
1.3.6.1.4.1.674.10892.1.300.10.1.30.1
=
1
1.3.6.1.4.1.674.10892.1.300.10.1.31.1
=
15
1.3.6.1.4.1.674.10892.1.300.10.1.32.1
=
0
1.3.6.1.4.1.674.10892.1.300.10.1.33.1
=
27
1.3.6.1.4.1.674.10892.1.300.10.1.34.1
=
0
1.3.6.1.4.1.674.10892.1.300.10.1.35.1
=
1
1.3.6.1.4.1.674.10892.1.300.10.1.36.1
=
480
1.3.6.1.4.1.674.10892.1.300.10.1.37.1
=
1
1.3.6.1.4.1.674.10892.1.300.10.1.38.1
=
2
1.3.6.1.4.1.674.10892.1.300.10.1.39.1
=
2
1.3.6.1.4.1.674.10892.1.300.10.1.44.1
=
0
1.3.6.1.4.1.674.10892.1.300.10.1.45.1
=
0
1.3.6.1.4.1.674.10892.1.300.40.1.1.1.1
=
1
1.3.6.1.4.1.674.10892.1.300.40.1.2.1.1
=
1
1.3.6.1.4.1.674.10892.1.300.40.1.3.1.1
=
8
1.3.6.1.4.1.674.10892.1.300.40.1.4.1.1
=
2
1.3.6.1.4.1.674.10892.1.300.40.1.5.1.1
=
'Log cleared'
1.3.6.1.4.1.674.10892.1.300.40.1.6.1.1
=
2
1.3.6.1.4.1.674.10892.1.300.40.1.7.1.1
=
3
1.3.6.1.4.1.674.10892.1.300.40.1.8.1.1
=
'20050513100047.000000-360'
SNMP Sample Output
Glossary
The following list defines or identifies technical terms, abbreviations, and acronyms used in
Dell™ user documents.
A
ASCII
Abbreviation for ampere(s).
Acronym for American Standard Code for Information
Interchange. A text file containing only characters from
the ASCII character set (usually created with a text
editor, such as Notepad in Microsoft® Windows®), is
called an ASCII file.
AC
Abbreviation for alternating current.
AC power switch
A switch with two AC power inputs that provides
AC power redundancy by failing over to a standby
AC input in the event of a failure to the
primary AC input.
ASIC
Acronym for application-specific integrated circuit.
ASPI
Advanced SCSI programming interface.
access
Refers to the actions a user can take on a variable value.
Examples include read-only and read-write.
ASR
adapter card
asset tag code
An expansion card that plugs into an expansion-card
connector on the computer’s system board. An adapter
card adds some specialized function to the computer
by providing an interface between the expansion bus
and a peripheral device. Examples of adapter cards
include network cards, sound cards, and SCSI adapters.
An individual code assigned to a computer, usually by
a system administrator, for security or tracking
purposes.
ADB
Abbreviation for assign database.
Abbreviation for automatic system recovery.
attribute
An attribute, or property, contains a specific piece of
information related to a component. Attributes can be
combined to form groups. If an attribute is defined as
read-write, it may be defined by a management
application.
AGP
Abbreviation for Advanced Graphics Port. A high
performance graphics interface becoming available for
Pentium Pro systems.
autoexec.bat file
The autoexec.bat file is executed when you boot your
computer (after executing any commands in the
config.sys file). This start-up file contains commands
that define the characteristics of each device connected
to your computer, and it finds and executes programs
stored in locations other than the active directory.
Glossary
611
backup
BMC
A copy of a program or data file. As a precaution, you
should back up your computer’s hard drive on a regular
basis. Before making a change to the configuration of
your computer, you should back up important start-up
files from your operating system.
Abbreviation for baseboard management controller,
which is a controller that provides the intelligence in
the IPMI structure.
baud rate
A measurement of data transmission speed. For
example, modems are designed to transmit data at one
or more specified baud rate(s) through the COM (serial)
port of a computer.
beep code
A diagnostic message in the form of a pattern of beeps
from your computer’s speaker. For example, one beep,
followed by a second beep, and then a burst of three
beeps is beep code 1-1-3.
BGA
Abbreviation for Ball Grid Array, an IC package that
uses an array of solder balls, instead of pins, to connect
to a PC board.
boot routine
When you start your computer, it clears all
memory, initializes devices, and loads the operating
system. Unless the operating system fails to respond,
you can reboot (also called warm boot) your computer
by pressing <Ctrl><Alt><Del>; otherwise, you
must perform a cold boot by pressing the reset
button or by turning the computer off and then
back on.
bootable diskette
You can start your computer from a diskette. To make
a bootable diskette, insert a diskette in the diskette
drive, type sys a: at the command line prompt, and
press <Enter>. Use this bootable diskette if your
computer will not boot from the hard drive.
bpi
Abbreviation for bits per inch.
binary
A base-2 numbering system that uses 0 and 1 to
represent information. The computer performs
operations based on the ordering and calculation of
these numbers.
bps
Abbreviation for bits per second.
BTU
Abbreviation for British thermal unit.
BIOS
Acronym for basic input/output system. Your
computer’s BIOS contains programs stored on a
flash memory chip. The BIOS controls the following:
Communications between the microprocessor and
peripheral devices, such as the keyboard and the
video adapter
Miscellaneous functions, such as system messages
bit
The smallest unit of information interpreted by your
computer.
612
Glossary
bus
An information pathway between the components of a
computer. Your computer contains an expansion bus
that allows the microprocessor to communicate
with controllers for all the various peripheral devices
connected to the computer. Your computer also
contains an address bus and a data bus for
communications between the microprocessor
and RAM.
byte
Eight contiguous bits of information, the basic data
unit used by your computer.
C
CIM
Abbreviation for Celsius.
Acronym for Common Information Model, which is a
model for describing management information from
the DMTF. CIM is implementation independent,
allowing different management applications to collect
the required data from a variety of sources.
CIM includes schemas for systems, networks,
applications and devices, and new schemas will be
added. It provides mapping techniques for interchange
of CIM data with MIB data from SNMP agents and
MIF data from DMI-compliant systems.
cache
A fast storage area that keeps a copy of data or
instructions for quicker data retrieval. For example,
your computer’s BIOS may cache ROM code in faster
RAM. Or, a disk-cache utility may reserve RAM in
which to store frequently accessed information from
your computer’s disk drives; when a program makes a
request to a disk drive for data that is in the cache, the
disk-cache utility can retrieve the data from RAM faster
than from the disk drive.
capability
Refers to the actions that an object can perform, or
actions that can be taken on a managed object.
For example, if a card is hot-pluggable, it is capable of
being replaced while the system power is ON.
CIMOM
Acronym for common information model object
manager.
CI/O
Acronym for comprehensive input/output.
CMOS
CDRAM
Abbreviation for cached DRAM, which is a high-speed
DRAM memory chip developed by Mitsubishi that
includes a small SRAM cache.
Acronym for complementary metal-oxide
semiconductor. In computers, CMOS memory chips
are often used for NVRAM storage.
COMn
CD-ROM
Abbreviation for compact disc read-only memory.
CD drives use optical technology to read data from CDs.
CDs are read-only storage devices; you cannot write
new data to a CD with standard CD drives.
chip
A set of microminiaturized, electronic circuits that are
designed for use as processors and memory in
computers. Small chips can hold from a handful to tens
of thousands of transistors. They look like tiny chips of
aluminum, no more than 1/16" square by 1/30" thick,
which is where the term "chip" came from. Large chips,
which can be more than a half inch square, hold
millions of transistors. It is actually only the top one
thousandth of an inch of a chip's surface that holds the
circuits. The rest of it is just a base.
The device names for the first through fourth serial
ports on your computer are COM1, COM2, COM3,
and COM4. The default interrupt for COM1 and
COM3 is IRQ4, and the default interrupt for COM2
and COM4 is IRQ3. Therefore, you must be careful
when configuring software that runs a serial device so
that you don’t create an interrupt conflict.
component
As they relate to DMI, manageable components are
operating systems, computer systems, expansion cards,
or peripherals that are compatible with DMI. Each
component is made up of groups and attributes that
are defined as relevant to that component.
config.sys file
The config.sys file is executed when you boot your
computer (before running any commands in the
autoexec.bat file). This start-up file contains commands
that specify which devices to install and which drivers
Glossary
613
to use. This file also contains commands that determine
how the operating system uses memory and
controls files.
recalculating the CRC and comparing it to the value
originally transmitted, the receiver can detect some
types of transmission errors.
controller
cursor
A chip that controls the transfer of data between the
microprocessor and memory or between the
microprocessor and a peripheral device such as a disk
drive or the keyboard.
A marker, such as a block, underscore, or pointer that
represents the position at which the next keyboard or
mouse action will occur.
DAT
control panel
Acronym for digital audio tape.
The part of the computer that contains indicators and
controls, such as the power switch, hard drive access
indicator, and power indicator.
dB
conventional memory
dBA
The first 640 KB of RAM. Conventional memory is
found in all computers.
Abbreviation for adjusted decibel(s).
Abbreviation for decibel(s).
DC
COO
Acronym for cost of ownership.
Abbreviation for direct current.
device driver
cooling unit
Sets of fans or other cooling devices in a system chassis.
coprocessor
A chip that relieves the computer’s microprocessor of
specific processing tasks. A math coprocessor, for
example, handles numeric processing. A graphics
coprocessor handles video rendering. The Intel®
Pentium® microprocessor, for example, includes a
built-in math coprocessor.
A program that allows the operating system or some
other program to interface correctly with a peripheral
device, such as a printer. Some device drivers—such as
network drivers—must be loaded from the config.sys
file (with a device= statement) or as memory-resident
programs (usually, from the autoexec.bat file). Others—
such as video drivers—must load when you start the
program for which they were designed.
DIMM
Abbreviation for characters per inch.
Acronym for dual in-line memory module. A small
circuit board containing DRAM chips that connects to
the system board.
CPU
DIN
Abbreviation for central processing unit. See also
microprocessor.
Acronym for Deutsche Industrie Norm which is the
standards-setting organization for Germany.
cpi
CRC
Abbreviation for cyclic redundancy code, which is a
number derived from, and stored or transmitted with,
a block of data in order to detect corruption. By
614
Glossary
A DIN connector is a connector that conforms to one
of the many standards defined by DIN. DIN connectors
are used widely in personal computers. For example,
the keyboard connector for PCs is a DIN connector.
DIP
DPMS
Acronym for dual in-line package. A circuit board, such
as a system board or expansion card, may contain
DIP switches for configuring the circuit board.
DIP switches are always toggle switches, with an
ON position and an OFF position.
Abbreviation for Display Power Management
Signaling. A standard developed by the Video
Electronics Standards Association (VESA®) that
defines the hardware signals sent by a video controller
to activate power management states in a monitor.
A monitor is said to be DPMS-compliant when it is
designed to enter a power management state after
receiving the appropriate signal from a computer’s
video controller.
directory
Directories help keep related files organized on a disk
in a hierarchical, "inverted tree" structure. Each disk
has a "root" directory; for example, a C:\> prompt
normally indicates that you are at the root directory of
hard-drive C. Additional directories that branch off of
the root directory are called subdirectories.
Subdirectories may contain additional directories
branching off of them.
display adapter
See video adapter.
DRAC
Abbreviation for Dell Remote Access Card.
DRAM
Acronym for dynamic random-access memory.
A computer’s RAM is usually made up entirely of
DRAM chips. Because DRAM chips cannot store an
electrical charge indefinitely, your computer
continually refreshes each DRAM chip in the computer.
DMA
Abbreviation for direct memory access. A DMA
channel allows certain types of data transfer between
RAM and a device to bypass the microprocessor.
DMI
Abbreviation for Desktop Management Interface.
DMI enables the management of your computer
system’s software and hardware. DMI collects
information about the system’s components, such as
the operating system, memory, peripherals, expansion
cards, and asset tag. Information about the system’s
components is displayed as a MIF file or through the
Dell Inspector program.
drive-type number
Your computer can recognize a number of specific hard
drives. Each is assigned a drive-type number that is
stored in NVRAM. The hard drive(s) specified in your
computer’s System Setup program must match the
actual drive(s) installed in the computer. The System
Setup program also allows you to specify physical
parameters (logical cylinders, logical heads, cylinder
number, and logical sectors per pack) for drives not
included in the table of drive types stored in NVRAM.
DMTF
Abbreviation for Distributed Management Task Force,
a consortium of companies representing hardware and
software providers, of which Dell is a member.
dpi
Abbreviation for dots per inch.
Glossary
615
DTE
EISA
Abbreviation for data terminal equipment. Any device,
such as a computer system, that can send data in digital
form by means of a cable or communications line. The
DTE is connected to the cable or communications line
through a data communications equipment (DCE)
device, such as a modem.
Acronym for Extended Industry-Standard
Architecture, a 32-bit expansion-bus design. The
expansion-card connectors in an EISA computer are
also compatible with 8- or 16-bit ISA expansion cards.
ECC
Abbreviation for error checking and correction.
ECP
Abbreviation for Extended Capabilities Port.
EMC
Abbreviation for Electromagnetic Compatibility.
EDO
Acronym for extended data output dynamic random
access memory which is a type of DRAM that is faster
than conventional DRAM. EDO RAM can start
fetching the next block of memory at the same time
that it sends the previous block to the CPU.
EEPROM
Acronym for electrically erasable programmable
read-only memory.
EMI
Abbreviation for electromagnetic interference.
EMM
Abbreviation for expanded memory manager. A utility
that uses extended memory to emulate expanded
memory on computers with an Intel386™ or
higher microprocessor.
EMS
EIDE
Abbreviation for enhanced integrated drive electronics.
EIDE devices add one or more of the following
enhancements to the traditional IDE standard:
Data transfer rates of up to 16 MB/sec
Support for drives other than just hard drives, such as
CD and tape drives
Support for hard drives with capacities greater than
528 MB
Support for up to two controllers, each with up to two
devices attached
616
To avoid a configuration conflict when installing an
EISA expansion card, you must use the EISA
Configuration Utility. This utility allows you to specify
which expansion slot contains the card and obtains
information about the card’s required system resources
from a corresponding EISA configuration file.
Glossary
Abbreviation for Expanded Memory Specification.
EPP
Abbreviation for Enhanced Parallel Port which
provides improved bidirectional data transmission.
Many devices are designed to take advantage of the
EPP standard, especially devices, such as network or
SCSI adapters that connect to the parallel port of a
portable computer.
EPROM
Acronym for erasable programmable read-only memory.
ESD
FCC
Abbreviation for electrostatic discharge.
Abbreviation for Federal Communications Commission.
ESM
FEPROM
Abbreviation for Embedded Systems Management.
Acronym for Flash Erasable Programmable Read-Only
Memory. Flash memory is a kind of non-volatile storage
device similar to EEPROM, but the erasing is done only
in blocks or the entire chip.
expanded memory
A technique for accessing RAM above 1 MB.
To enable expanded memory on your computer, you
must use an EMM. You should configure your system
to support expanded memory only if you run
application programs that can use (or require)
expanded memory.
flash BIOS
A PC BIOS that is stored in flash memory rather than
in a ROM. A flash BIOS chip can be updated in place,
whereas a ROM BIOS must be replaced with a
newer chip.
expansion bus
Your computer contains an expansion bus that allows
the microprocessor to communicate with controllers
for peripheral devices, such as a network card or an
internal modem.
flash memory
A type of EEPROM chip that can be reprogrammed
from a utility on diskette while still installed in a
computer; most EEPROM chips can only be rewritten
with special programming equipment.
expansion-card connector
A connector on the computer’s system board or riser
board for plugging in an expansion card.
extended memory
RAM above 1 MB. Most software that can use it, such
as the Windows operating system, requires that
extended memory be under the control of an XMM.
external cache memory
A RAM cache using SRAM chips. Because SRAM chips
operate at several times the speed of DRAM chips, the
microprocessor can retrieve data and instructions faster
from external cache memory than from RAM.
format
To prepare a hard drive or diskette for storing files.
An unconditional format deletes all data stored on
the disk.
FPBGA
Acronym for field programmable gate array, a
programmable logic chip (PLD) with a high density
of gates.
FRU
Acronym for field replaceable unit.
ft
F
Abbreviation for feet.
Abbreviation for Fahrenheit.
FTP
FAT
Acronym for file allocation table. The Windows NT®
operating systems can optionally use a FAT file system
structure.
Abbreviation for file transfer protocol.
g
Abbreviation for gram(s).
Glossary
617
G
HIP
Abbreviation for gravities.
Abbreviation for Hardware Instrumentation
Package (HIP).
GB
Abbreviation for gigabyte(s). A gigabyte equals
1,024 megabytes or 1,073,741,824 bytes.
graphics coprocessor
See coprocessor.
HMA
Abbreviation for high memory area. The first 64 KB of
extended memory above 1 MB. A memory manager
that conforms to the XMS can make the HMA a direct
extension of conventional memory. See also
upper memory area and XMM.
graphics mode
A video mode that can be defined as x horizontal by
y vertical pixels by z colors.
host adapter
As it relates to DMI, a group is a data structure that
defines common information, or attributes, about a
manageable component.
A host adapter implements communication between
the computer’s bus and the controller for a peripheral
device. (hard-drive controller subsystems include
integrated host adapter circuitry.) To add a SCSI
expansion bus to your system, you must install or
connect the appropriate host adapter.
GTL
hot plug
group
Abbreviation for ground termination logic.
GUI
Acronym for graphical user interface.
h
Abbreviation for hexadecimal. A base-16 numbering
system, often used in programming to identify
addresses in the computer’s RAM and I/O memory
addresses for devices. The sequence of decimal
numbers from 0 through 16, for example, is expressed
in hexadecimal notation as: 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, A,
B, C, D, E, F, 10. In text, hexadecimal numbers are
often followed by h.
The ability to remove and replace a redundant part
while the system is being used. Also called a "hot spare."
HPFS
Abbreviation for the High Performance File System
option in the Windows NT operating systems.
Hz
Abbreviation for hertz.
ICES
Abbreviation for Interface-Causing Equipment
Standard (in Canada).
ICU
heat sink
Abbreviation for ISA Configuration Utility.
A metal plate with metal pegs or ribs that help dissipate
heat. Most microprocessors include a heat sink.
IDE
Abbreviation for Integrated Device Electronics. IDE is
a computer system interface, used primarily for hard
drives and CDs.
618
Glossary
I/O
IPX
Abbreviation for input/output. The keyboard is an
input device, and a printer is an output device. In
general, I/O activity can be differentiated from
computational activity. For example, when a program
sends a document to the printer, it is engaging in
output activity; when the program sorts a list of terms,
it is engaging in computational activity.
Acronym for internetwork packet exchange.
ID
Abbreviation for identification.
IRQ
Abbreviation for interrupt request. A signal that data
is about to be sent to or received by a peripheral device
travels by an IRQ line to the microprocessor. Each
peripheral connection must be assigned an IRQ
number. For example, the first serial port in your
computer (COM1) is assigned to IRQ4 by default.
Two devices can share the same IRQ assignment, but
you cannot operate both devices simultaneously.
IHV
Acronym for independent hardware vendor. IHVs often
develop their own MIBs for components that they
manufacture.
interlacing
A technique for increasing video resolution by only
updating alternate horizontal lines on the screen.
Because interlacing can result in noticeable screen
flicker, most users prefer noninterlaced video adapter
resolutions.
internal microprocessor cache
An instruction and data cache built in to the
microprocessor. The Intel Pentium microprocessor
includes a 16-KB internal cache, which is set up as an
8-KB read-only instruction cache and an 8-KB
read/write data cache.
ISA
Acronym for Industry-Standard Architecture. A 16-bit
expansion bus design. The expansion-card connectors
in an ISA computer are also compatible with 8-bit ISA
expansion cards.
ITE
Abbreviation for information technology equipment.
jumper
Jumpers are small blocks on a circuit board with two or
more pins emerging from them. Plastic plugs
containing a wire fit down over the pins. The wire
connects the pins and creates a circuit. Jumpers provide
a simple and reversible method of changing the
circuitry in a printed circuit board.
K
IP Address
Abbreviation for kilo-, indicating 1,000.
Abbreviation for Internet Protocol address. See TCP/IP.
KB
IPMI
Abbreviation for Intelligent Platform Management
Interface, which is an industry standard for
management of peripherals used in enterprise
computers based on Intel architecture. The key
characteristic of IPMI is that inventory, monitoring,
logging, and recovery control functions are available
independent of the main processors, BIOS, and
operating system.
Abbreviation for kilobyte(s), 1,024 bytes.
KB/sec
Abbreviation for kilobyte(s) per second.
Kbit(s)
Abbreviation for kilobit(s), 1,024 bits.
Kbit(s)/sec
Abbreviation for kilobit(s) per second.
Glossary
619
key combination
LPTn
A command requiring you to press multiple keys at the
same time. For example, you can reboot your computer
by pressing the <Ctrl><Alt><Del> key combination.
The device names for the first through third parallel
printer ports on your computer are LPT1, LPT2,
and LPT3.
kg
LRA
Abbreviation for kilogram(s), 1,000 grams.
Acronym for local response agent.
kHz
m
Abbreviation for kilohertz, 1,000 hertz.
Abbreviation for meter(s).
LAN
mA
Acronym for local area network. A LAN system is
usually confined to the same building or a few nearby
buildings, with all equipment linked by wiring
dedicated specifically to the LAN.
Abbreviation for milliampere(s).
lb
math coprocessor
Abbreviation for pound(s).
See coprocessor.
LCC
Mb
Acronym for leaded or leadless chip carrier.
Abbreviation for megabit.
LIF
MB
Acronym for low insertion force. Some computers use
LIF sockets and connectors to allow devices, such as
the microprocessor chip, to be installed or removed
with minimal stress to the device.
Abbreviation for megabyte(s). The term megabyte
means 1,048,576 bytes; however, when referring to
hard-drive storage, the term is often rounded to mean
1,000,000 bytes.
LED
MB/sec
Abbreviation for light-emitting diode. An electronic
device that lights up when a current is passed through it.
Abbreviation for megabytes per second.
mAh
Abbreviation for milliampere-hour(s).
Mbps
local bus
On a computer with local-bus expansion capability,
certain peripheral devices (such as the video adapter
circuitry) can be designed to run much faster than they
would with a traditional expansion bus. Some local-bus
designs allow peripherals to run at the same speed and
with the same width data path as the computer’s
microprocessor.
620
Glossary
Abbreviation for megabits per second.
MBR
Abbreviation for master boot record.
MCA
Abbreviation for Micro Channel Architecture, which is
designed for multiprocessing. MCA eliminates potential
conflicts that arise when installing new peripheral
devices. MCA is not compatible with either EISA or XT
bus architecture, so older cards cannot be used with it.
memory
MIF
A computer can contain several different forms of
memory, such as RAM, ROM, and video memory.
Frequently, the word memory is used as a synonym for
RAM; for example, an unqualified statement such as
"a computer with 16 MB of memory" refers to a
computer with 16 MB of RAM.
Acronym for management information format.
A MIF file contains information, status, and links to
component instrumentation. MIF files are installed
into the MIF database by the DMI service layer. The
content of a MIF is defined by a DTMF working
committee and is published in the form of a MIF
definition document. This document identifies the
groups and attributes that are relevant to
DMI-manageable components.
memory address
A specific location, usually expressed as a hexadecimal
number, in the computer’s RAM.
mm
memory manager
Abbreviation for millimeter(s).
A utility that controls the implementation of memory
in addition to conventional memory, such as extended
or expanded memory.
modem
A device that allows your computer to communicate
with other computers over telephone lines.
memory module
A small circuit board containing DRAM chips that
connects to the system board.
MOF
Acronym for managed object format, which is an ASCII
file that contains the formal definition of a CIM schema.
MHz
Abbreviation for megahertz.
MIB
Acronym for management information base. MIB is
used to send detailed status/commands from or to an
SNMP managed device.
mouse
A pointing device that controls the movement of the
cursor on a screen. Mouse-aware software allows you to
activate commands by clicking a mouse button while
pointing at objects displayed on the screen.
MPEG
microprocessor
The primary computational chip inside the computer
that controls the interpretation and execution of
arithmetic and logic functions. Software written for one
microprocessor must usually be revised to run on another
microprocessor. CPU is a synonym for microprocessor.
Acronym for Motion Picture Experts Group. MPEG is
a digital video file format.
ms
Abbreviation for millisecond(s).
MTBF
MIDI
Abbreviation for mean time between failures.
Abbreviation for musical instrument digital interface.
Glossary
621
multifrequency monitor
NTFS
A monitor that supports several video standards.
A multifrequency monitor can adjust to the frequency
range of the signal from a variety of video adapters.
Abbreviation for the NT File System option in the
Windows NT operating system.
NuBus
mV
Abbreviation for millivolt(s).
Proprietary expansion bus used on Apple Macintosh
personal computers.
name
NVRAM
The name of an object or variable is the exact string
that identifies it in an SNMP Management
Information Base (MIB) file, or in a DMI Management
Information Format (MIF) file, or in a
CIM Management Object File (MOF).
Acronym for nonvolatile random-access memory.
Memory that does not lose its contents when you turn
off your computer. NVRAM is used for maintaining the
date, time, and system configuration information.
OID
NDIS
Abbreviation for Network Driver Interface
Specification.
Abbreviation for object identifier. An
implementation-specific integer or pointer that
uniquely identifies an object.
NIC
online access service
Acronym for network interface controller.
A service that typically provides access to the Internet,
E-mail, bulletin boards, chat rooms, and file libraries.
NIF
Acronym for network interface function. This term is
equivalent to NIC.
OTP
NMI
parallel port
Abbreviation for nonmaskable interrupt. A device
sends an NMI to signal the microprocessor about
hardware errors, such as a parity error.
An I/O port used most often to connect a parallel
printer to your computer. You can usually identify a
parallel port on your computer by its 25-hole connector.
noninterlaced
parameter
A technique for decreasing screen flicker by sequentially
refreshing each horizontal line on the screen.
A value or option that you specify to a program.
A parameter is sometimes called a switch or an argument.
ns
partition
Abbreviation for nanosecond(s), one billionth of a
second.
You can divide a hard drive into multiple physical
sections called partitions with the fdisk command. Each
partition can contain multiple logical drives.
Abbreviation for one-time programmable.
After partitioning the hard drive, you must format each
logical drive with the format command.
622
Glossary
PC 98
PGA
The third PC 9x specification, which defines five
categories (Consumer, Office, Mobile, Entertainment
and Workstation). It eliminates the ISA bus and
pushes the minimum requirements to a 200MHz CPU
with 32MB of RAM and 256K of L2 cache. PC 98
machines must support OnNow, and the BIOS must
support booting from a CD and be Y2K compliant.
Systems cannot ship with ISA cards installed, but may
have an ISA bus for legacy devices.
Abbreviation for pin grid array, a type of microprocessor
socket that allows you to remove the microprocessor chip.
PC card
physical memory array mapped
A credit-card sized, removable module for portable
computers standardized by PCMCIA. PC Cards are
also known as "PCMCIA cards." PC Cards are 16-bit
devices that are used to attach modems, network
adapters, sound cards, radio transceivers, solid state
disks and hard disks to a portable computer. The PC
Card is a "plug and play" device, which is configured
automatically by the Card Services software.
The physical memory array mapped refers to the way
physical memory is divided. For example, one mapped
area may have 640 KB and the other mapped area may
have between 1 Megabyte and 127 Megabytes.
PCI
Abbreviation for Peripheral Component Interconnect.
A standard for local-bus implementation developed by
Intel Corporation.
PCIX
Abbreviation for PCI extended.
PCMCIA
Personal Computer Memory Card International
Association. An international trade association that has
developed standards for devices, such as modems and
external hard drives, that can be plugged into
portable computers.
PERC
Acronym for PowerEdge Expandible RAID controller.
peripheral device
An internal or external device—such as a printer, a disk
drive, or a keyboard—connected to a computer.
physical memory array
The physical memory array is the entire physical
memory of a system. Variables for physical memory
array include maximum size, total number of
memory slots on the motherboard, and total number
of slots in use.
PIC
Acronym for programmable interrupt controller.
PIP
Acronym for peripheral interchange program. A CP/M
utility program that was used to copy files.
pixel
A single point on a video display. Pixels are arranged
in rows and columns to create an image. A video
resolution, such as 640 x 480, is expressed as the number
of pixels across by the number of pixels up and down.
PLCC
Acronym for plastic leaded chip carrier.
Plug and Play
An industry-standard specification that makes it
easier to add hardware devices to personal computers.
Plug and Play provides automatic installation and
configuration, compatibility with existing
hardware, and dynamic support of mobile
computing environments.
Glossary
623
PME
provider
Abbreviation for Power Management Event. A PME is
a pin on a peripheral component interconnect that
allows a PCI device to assert a wake event.
A provider is an extension of a CIM schema that
communicates with managed objects and accesses data
and event notifications from a variety of sources.
Providers forward this information to the CIM Object
Manager for integration and interpretation.
POST
Acronym for power-on self-test. Before the operating
system loads when you turn on your computer, the
POST tests various system components such as RAM,
the disk drives, and the keyboard.
PS/2
Abbreviation for Personal System/2.
PXE
power supply
An electrical system that converts AC current from the
wall outlet into the DC currents required by the computer
circuitry. The power supply in a personal computer
typically generates multiple voltages.
Abbreviation for Pre-boot eXecution Environment.
QFP
Acronym for quad flat pack.
RAID
power unit
A set of power supplies in a system chassis.
Acronym for redundant array of independent drives.
RAM
ppm
Abbreviation for pages per minute.
PQFP
Abbreviation for plastic quad flat pack, a type of
microprocessor socket in which the microprocessor
chip is permanently mounted.
Acronym for random-access memory. The computer’s
primary temporary storage area for program instructions
and data. Each location in RAM is identified by a
number called a memory address. Any information stored
in RAM is lost when you turn off your computer.
RAMBUS
protected mode
Acronym for Rambus DRAM, a type of memory
(DRAM) developed by Rambus, Inc.
An operating mode supported by 80286 or higher
microprocessors, protected mode allows operating
systems to implement:
RAMDAC
•
A memory address space of 16 MB (80286
microprocessor) to 4 GB (Intel386 or higher
microprocessor)
•
Multitasking
•
Virtual memory, a method for increasing addressable
memory by using the hard drive
Windows, OS/2, and UNIX® 32-bit operating systems run
in protected mode.
624
Glossary
Acronym for random-access memory digital-to-analog
converter.
RAW
Unprocessed. The term refers to data that is passed
along to an I/O device without being interpreted. In
contrast, cooked refers to data that is processed before
being passed to the I/O device.
It often refers to uncompressed text that is not stored
in any proprietary format. The term comes from UNIX,
which supports cooked and raw modes for data output
to a terminal.
RDRAM
RGB
Acronym for Rambus DRAM. A dynamic RAM chip
technology from Rambus, Inc. Direct RDRAMs are
used in computers. Direct RDRAM chips are housed
in RIMM modules, which are similar to DIMMs but
have different pin settings. The chips can be built with
dual channels, doubling the transfer rate to 3.2 GB/sec.
Abbreviation for red/green/blue.
RIMM
Acronym for Rambus In-line Memory Module, which
is the Rambus equivalent of a DIMM module.
ROM
read-only file
A read-only file is one that you are prohibited from
editing or deleting. A file can have read-only status if:
Its read-only attribute is enabled.
It resides on a physically write-protected diskette or on
a diskette in a write-protected drive.
Acronym for read-only memory. Your computer
contains some programs essential to its operation in
ROM code. Unlike RAM, a ROM chip retains its
contents even after you turn off your computer.
Examples of code in ROM include the program that
initiates your computer’s boot routine and the POST.
It is located on a network in a directory to which the
system administrator has assigned read-only rights to you.
rpm
readme file
RTC
A text file included with a software package or hardware
product that contains information supplementing or
updating the documentation for the software or
hardware. Typically, readme files provide installation
information, describe new product enhancements or
corrections that have not yet been documented, and
list known problems or other things you need to be
aware of as you use the software or hardware.
Abbreviation for real-time clock. Battery-powered
clock circuitry inside the computer that keeps the date
and time after you turn off the computer.
real mode
An operating mode supported by 80286 or higher
microprocessors, real mode imitates the architecture of
an 8086 microprocessor.
refresh rate
The rate at which the monitor redraws the video image
on the monitor screen. More precisely, the refresh rate
is the frequency, measured in Hz, at which the screen’s
horizontal lines are recharged (sometimes also referred
to as its vertical frequency). The higher the refresh rate,
the less video flicker can be seen by the human eye. The
higher refresh rates are also noninterlaced.
RFI
Abbreviation for revolutions per minute.
SAS
Acronym for Serial Attached SCSI.
SCA
Acronym for single connector attachment.
schema
A collection of class definitions that describes managed
objects in a particular environment. A CIM schema is
a collection of class definitions used to represent
managed objects that are common to every
management environment, which is why CIM is called
the Common Information Model.
SCSI
Acronym for small computer system interface. An I/O
bus interface with faster data transmission rates than
standard ports. You can connect up to seven devices
(15 for some newer SCSI types) to one SCSI interface.
Abbreviation for radio frequency interference.
Glossary
625
SDMS
SIMM
Abbreviation for SCSI device management system.
Acronym for single in-line memory module. A small
circuit board containing DRAM chips that connects to
the system board.
sec
Abbreviation for second(s).
SIP
SEC
Abbreviation for single-edge contact.
serial port
Acronym for single in-line package, which is a type of
housing for electronic components in which the
connecting pins protrude from one side. A SIP is also
called a Single In-line Pin Package (SIPP).
An I/O port used most often to connect a modem to
your computer. You can usually identify a serial port
on your computer by its 9-pin connector.
SKU
settings
SMART
Settings are conditions of a manageable object help to
determine what happens when a certain value is
detected in a component. For example, a user can set
the upper critical threshold of a temperature probe to
75 degrees Celsius. If the probe reaches that
temperature, the setting results in an alert being sent
to the management console so that user intervention
can be taken. Some settings, when reached, can trigger
a system shutdown or other response that can prevent
damage to the system.
Acronym for Self-Monitoring Analysis Reporting
Technology. A technology that allows hard drives to
report errors and failures to the system BIOS, which
then displays an error message on the screen. To take
advantage of this technology, you must have a
SMART-compliant hard drive and the proper support
in the system BIOS.
service tag number
SMD
A bar code label on the computer that identifies it when
you call Dell for customer or technical support.
Acronym for surface mount device.
Acronym for stock keeping unit.
SMBIOS
Acronym for system management BIOS.
SNMP
SGRAM
Acronym for synchronous graphics RAM.
shadowing
A computer’s system and video BIOS code is usually
stored on ROM chips. Shadowing refers to the
performance-enhancement technique that copies
BIOS code to faster RAM chips in the upper memory
area (above 640 KB) during the boot routine.
Abbreviation for Simple Network Management
Protocol. SNMP is an industry-standard interface that
allows a network manager to remotely monitor and
manage workstations.
SODIMM
Acronym for small outline-DIMM. A DIMM module with
a thinner profile due to the use of TSOP chip packages.
SODIMMs are commonly used in laptop computers.
SIMD
SOIC
Abbreviation for Single Instruction Multiple Data.
Acronym for Small Outline IC, a small-dimension,
plastic, rectangular, surface mount chip package that
uses gull-wing pins extending outward.
626
Glossary
SOJ
syntax
Acronym for small outline package J-lead, a
small-dimension, plastic, rectangular surface mount
chip package with j-shaped pins on its two long sides.
The rules that dictate how you must type a command
or instruction so that the computer understands it.
A variable’s syntax indicates its data type.
SRAM
system board
Abbreviation for static random-access memory.
Because SRAM chips do not require continual
refreshing, they are substantially faster than
DRAM chips.
As the main circuit board, the system board usually
contains most of your computer’s integral components,
such as the following:
•
Microprocessor
state
•
RAM
Refers to the condition of an object that can have more
than one condition. For example, an object may be in
the "not ready" state.
•
Controllers for standard peripheral devices, such as
the keyboard
•
Various ROM chips
status
Refers to the health or functioning of an object. For
example, a temperature probe can have the status
normal if the probe is measuring acceptable temperatures.
When the probe begins reading temperatures that
exceed limits set by the user, it reports a critical status.
SVGA
Abbreviation for super video graphics array. VGA and
SVGA are video standards for video adapters with
greater resolution and color display capabilities than
previous standards.
To display a program at a specific resolution, you must
install the appropriate video drivers and your monitor
must support the resolution. Similarly, the number of
colors that a program can display depends on the
capabilities of the monitor, the video driver, and the
amount of video memory installed in the computer.
switch
On a computer system board, switches control various
circuits or functions in your computer system. These
switches are known as DIP switches; they are normally
packaged in groups of two or more switches in a plastic
case. Two common DIP switches are used on system
boards: slide switches and rocker switches. The names of
the switches are based on how the settings (on and off)
of the switches are changed.
Frequently used synonyms for system board are
motherboard and logic board.
system configuration information
Data stored in memory that tells a computer what
hardware is installed and how the computer should be
configured for operation.
system diskette
System diskette is a synonym for bootable diskette.
system memory
System memory is a synonym for RAM.
System Setup program
A BIOS-based program that allows you to configure
your computer’s hardware and customize the
computer’s operation by setting such features as
password protection and energy management. Some
options in the System Setup program require that you
reboot the computer (or the computer may reboot
automatically) in order to make a hardware
configuration change. Because the System Setup
program is stored in NVRAM, any settings remain in
effect until you change them again.
Glossary
627
system.ini file
threshold values
A start-up file for the Windows operating system.
When you start Windows, it consults the system.ini file
to determine a variety of options for the Windows
operating environment. Among other things, the
system.ini file records which video, mouse, and
keyboard drivers are installed for Windows.
Systems are normally equipped with various sensors
that monitor temperature, voltage, current, and fan
speed. The sensor’s threshold values specify the ranges
(min and max values) for determining whether the
sensor is operating under normal, noncritical, critical
or fatal conditions. Dell-supported threshold values are
Running the Control Panel or Windows Setup program
may change options in the system.ini file. On other
occasions, you may need to change or add options to
the system.ini file manually with a text editor, such
as Notepad.
UpperThresholdFatal
UpperThresholdCritical
UpperThresholdNon-critical
Normal
LowerThresholdNon-critical
table
In SNMP MIBs, a table is a two dimensional array that
describes the variables that make up a managed object.
LowerThresholdCritical
TCP/IP
time-out
Abbreviation for Transmission Control
Protocol/Internet Protocol. A system for transferring
information over a computer network containing
dissimilar systems, such as systems running
Windows and UNIX.
A specified period of system inactivity that must occur
before an energy conservation feature is activated.
termination
TQFP
Some devices (such as the last device at each end of a
SCSI cable) must be terminated to prevent reflections
and spurious signals in the cable. When such devices
are connected in a series, you may need to enable or
disable the termination on these devices by changing
jumper or switch settings on the devices or by changing
settings in the configuration software for the devices.
Acronym for thin quad flat pack.
text editor
An application program for editing text files consisting
exclusively of ASCII characters. Windows Notepad is
a text editor, for example. Most word processors use
proprietary file formats containing binary characters,
although some can read and write text files.
text mode
A video mode that can be defined as x columns by
y rows of characters.
628
Glossary
LowerThresholdFatal
tpi
Abbreviation for tracks per inch.
TSR
Abbreviation for terminate-and-stay-resident. A TSR
program runs "in the background." Most TSR
programs implement a predefined key combination
(sometimes referred to as a hot key) that allows you
to activate the TSR program’s interface while running
another program. When you finish using the TSR
program, you can return to the other application
program and leave the TSR program resident in
memory for later use.
TSR programs can sometimes cause memory conflicts.
When troubleshooting, rule out the possibility of such
a conflict by rebooting your computer without starting
any TSR programs.
TSOP
utility
Acronym for thin small outline package. A very-thin,
plastic, rectangular surface mount chip package with
gull-wing pins on its two short sides. TSOPs are about
a third as thick as SOJ chips.
A program used to manage system resources—memory,
disk drives, or printers, for example.
UTP
Abbreviation for unshielded twisted pair.
UART
Acronym for universal asynchronous receiver transmitter,
the electronic circuit that makes up the serial port.
UUID
UDP
V
Acronym for user datagram protocol.
Abbreviation for volt(s).
UL
VAC
Abbreviation for Underwriters Laboratories.
Abbreviation for volt(s) alternating current.
UMB
varbind
Abbreviation for upper memory blocks.
A fixed width, 16-bit world wide character encoding,
developed and maintained by the Unicode Consortium.
An algorithm used to assign and object identifier or
OID. The varbind gives rules for arriving at the decimal
prefix that uniquely identifies an enterprise, as well as
the formula for specifying a unique identifier for the
objects defined in that enterprise’s MIB.
upper memory area
variable
The 384 KB of RAM located between 640 KB and
1 MB. If the computer has an Intel386 or higher
microprocessor, a utility called a memory manager
can create UMBs in the upper memory area, in
which you can load device drivers and
memory-resident programs.
A component of a managed object. A temperature
probe, for example, has a variable to describe its
capabilities, its health or status, and certain indexes
that you can use to help you in locating the right
temperature probe.
unicode
Acronym for Universal Unique Identification.
VCCI
UPS
Abbreviation for uninterruptible power supply.
A battery-powered unit that automatically supplies
power to your computer in the event of an
electrical failure.
Abbreviation for Voluntary Control Council for
Interference.
VCR
Abbreviation for video cassette recorder.
USB
VDC
Abbreviation for Universal Serial Bus. A USB connector
provides a single connection point for multiple
USB-compliant devices, such as mice, keyboards,
printers, and computer speakers. USB devices can
also be connected and disconnected while the
system is running.
Abbreviation for volt(s) direct current.
VESA
Acronym for Video Electronics Standards Association.
Glossary
629
VGA
video memory
Abbreviation for video graphics array. VGA and SVGA
are video standards for video adapters with greater
resolution and color display capabilities than previous
standards. To display a program at a specific resolution,
you must install the appropriate video drivers and your
monitor must support the resolution. Similarly, the
number of colors that a program can display depends on
the capabilities of the monitor, the video driver, and the
amount of video memory installed for the video adapter.
Most VGA and SVGA video adapters include memory
chips in addition to your computer’s RAM. The amount
of video memory installed primarily influences the
number of colors that a program can display (with the
appropriate video drivers and monitor capabilities).
VGA feature connector
On some systems with a built-in VGA video adapter, a
VGA feature connector allows you to add an
enhancement adapter, such as a video accelerator, to
your computer. A VGA feature connector can also be
called a VGA pass-through connector.
video adapter
The logical circuitry that provides—in combination
with the monitor—your computer’s video capabilities.
A video adapter may support more or fewer features
than a specific monitor offers. Typically, a video
adapter comes with video drivers for displaying popular
application programs and operating systems in a variety
of video modes.
On some Dell computers, a video adapter is integrated
into the system board. Also available are many
video adapter cards that plug into an
expansion-card connector.
Video adapters often include memory separate from
RAM on the system board. The amount of video
memory, along with the adapter’s video drivers, may
affect the number of colors that can be simultaneously
displayed. Video adapters can also include their own
coprocessor for faster graphics rendering.
video driver
A program that allows graphics-mode application
programs and operating systems to display at a chosen
resolution with the desired number of colors.
A software package may include some "generic" video
drivers. Any additional video drivers may need to match
the video adapter installed in the computer.
630
Glossary
video mode
Video adapters normally support multiple text and
graphics display modes. Character-based software
displays in text modes that can be defined as x columns
by y rows of characters. Graphics-based software
displays in graphics modes that can be defined as
x horizontal by y vertical pixels by z colors.
video resolution
Video resolution—800 x 600, for example—is
expressed as the number of pixels across by the number
of pixels up and down. To display a program at a specific
graphics resolution, you must install the appropriate
video drivers and your monitor must support
the resolution.
virtual memory
A method for increasing addressable RAM by using the
hard drive. For example, in a computer with 16 MB of
RAM and 16 MB of virtual memory set up on the hard
drive, the operating system would manage the system
as though it had 32 MB of physical RAM.
virus
A self-starting program designed to inconvenience you.
Virus programs have been known to corrupt the files
stored on a hard drive or to replicate themselves until
a computer or network runs out of memory.
The most common way that virus programs move from
one computer to another is via "infected" diskettes, from
which they copy themselves to the hard drive. To guard
against virus programs, you should do the following:
•
Periodically run a virus-checking utility on your
computer’s hard drive
•
Always run a virus-checking utility on any diskettes
(including commercially sold software) before
using them
VLSI
win.ini file
Abbreviation for very-large-scale integration.
A start-up file for the Windows operating system. When
you start Windows, it consults the win.ini file to
determine a variety of options for the Windows
operating environment. Among other things, the win.ini
file records what printer(s) and fonts are installed for
Windows. The win.ini file also usually includes sections
that contain optional settings for Windows application
programs that are installed on the hard drive.
VLVESA
Acronym for very low voltage enterprise system
architecture.
vpp
Abbreviation for peak-point voltage.
VRAM
Acronym for video random-access memory. Some
video adapters use VRAM chips (or a combination of
VRAM and DRAM) to improve video performance.
VRAM is dual-ported, allowing the video adapter to
update the screen and receive new image data at the
same time.
Running the Control Panel or Windows Setup program
may change options in the win.ini file. On other
occasions, you may need to change or add options to the
win.ini file manually with a text editor such as Notepad.
Windows 95
Abbreviation for voltage regulator module.
An integrated and complete Microsoft Windows
operating system that provides advanced operating
system performance, improved ease of use, enhanced
workgroup functionality, and simplified file
management and browsing.
W
Windows NT
Abbreviation for watt(s).
High-performance server and workstation operating
system software developed by Microsoft that is
intended for technical, engineering, and financial
applications.
VRM
Wakeup on LAN
The ability for the power in a client station to be turned
on by the network. Remote wake-up enables software
upgrading and other management tasks to be
performed on users' machines after the work day is over.
It also enables remote users to gain access to machines
that have been turned off. Intel calls remote wake-up
"Wake-on-LAN."
Read-only files are said to be write-protected. You can
write-protect a 3.5-inch diskette by sliding its writeprotect tab to the open position or by setting the writeprotect feature in the System Setup program.
WH
XMM
Abbreviation for watt-hour(s).
Abbreviation for extended memory manager, a utility
that allows application programs and operating systems
to use extended memory in accordance with the XMS.
write-protected
Glossary
631
XMS
Abbreviation for eXtended Memory Specification.
ZIF
Acronym for zero insertion force. Some computers use
ZIF sockets and connectors to allow devices such as the
microprocessor chip to be installed or removed with no
stress applied to the device.
ZIP
A 3.5 inch removable disk drive from Iomega.
Originally, it provided a 100 MB removable cartridges.
The drive is bundled with software that can catalog the
disks and lock the files for security.
A 250 MB version of the Zip drive also reads and writes
the 100 MB Zip cartridges.
632
Glossary
Index
Numerics
1403, 584
BIOS Setup Control
Group, 311
variable values, 335
COO Service Contract
Table, 364
COO Support Information
Table, 380
COO Trouble Ticket
Table, 383
COO Warranty Table, 368
Cost of Ownership Table, 353
Cost of Ownership tables, 353
1404, 585
1602, 588
1603, 588
C
1604, 588
Change, 557
1651, 589
Change Management
Group, 557
1652, 589
1653, 589
A
Application, 560
Application Group, 560
B
BIOS Group
BIOS Setup Control
Table, 311
Diskette Control Table, 331
IDE Control Table, 329
Network Interface Control
Table, 333
Parallel Port Control
Table, 323
SCSI Control Table, 321
Serial Port Control Table, 325
USB Control Table, 327
BIOS Group tables, 311
Chassis Information Group
tables, 55
Chassis Information Table, 55
Event Log Table, 71
Firmware Table, 79
Intrusion Table, 82, 85
POST Log Table, 69
System BIOS Table, 73
UUID Table, 67
Variable Values, 89
Cluster Group, 437
Cluster Table, 437
variable values, 440
Cost of Ownership Group
COO Cost Event Log
Table, 366
COO Lease Information
Table, 370
COO Maintenance Table, 376
COO Options Table, 374
COO Repair Table, 378
COO Schedule Number
Table, 373
D
data types
common, 601
state capabilities, 602
state settings, 602-603
status, 603
status probe, 604
status redundancy, 604
Device added to system, 589
Device configuration error
detected, 589
Device Group, 558
Cache Device Table, 228
Generic Device Table, 244
Keyboard Device Table, 216
Memory Device Mapped
Address Table, 241
Memory Device Table, 234
PCI Device Configuration
Space Table, 250
PCI Device Table, 247
Pointing Device Table, 213
Index
633
634
Index
Processor Device Table, 218
variable values, 261
Device removed from
system, 589
Local Response Agent Group
tables, 345
Physical Memory Card
Table, 303
Logical Devices Group, 544
Pluggable Device Traps, 589
M
E
Event Log
viewing entries, 597
G
Global Data Group, 464
I
Introduction
Server Administrator Change
Management MIB, 18
Server Administrator
Instrumentation MIB, 15
Server Administrator Remote
Access MIB, 16
Server Administrator Storage
Management MIB, 17
Memory device correction
rate crossed a warning
threshold, 584
Memory device ECC
Correctable error count
crossed a warning
threshold, 584
Memory Group
Physical Memory Tables, 289
variable values, 297, 303
Memory Group Variable
Values, 306
MIB
minor version number, 29
Port Group
Keyboard Port Table, 184
Memory Device Port
Table, 190
Monitor Port Table, 193
Parallel Port Table, 198
Pointing Port Table, 181
Processor Port Table, 187
Serial Port Table, 202
Small Computer System
Interface Port Table, 196
variable values, 209
Power Group
Amperage Probe Table, 138
Power Supply Table, 129
Power Unit Table, 127
variable values, 149
Voltage Probe Table, 133
MIB Major Version
Number, 29
Power Group tables, 127
O
Processor sensor detected a
failure value, 588
Inventory Group, 557
Operating System Group, 562
Memory Table, 103
Operating System Table, 101
Processor sensor detected a
warning value, 588
L
Operating System Memory
Table, 103
Inventory, 557
Local Response Agent Group
LRA Action Table, 348
LRA Global Settings, 345
LRA Global Settings
Table, 345
variable values, 350
634
Index
P
Physical Devices Group, 469
Processor Device Status
Traps, 588
Processor sensor returned to a
normal state, 588
R
Redundant Memory Unit
Table, 301
Remote Access Group
Remote Access Table, 393
Remote SNMP Trap
Table, 410
Remote User Administration
Table, 402
Remote User Dial-In
Configuration Table, 418
Remote User Dial-Out
Table, 421
Remote Flash BIOS Group
variable values, 178
S
sample SNMP output, 607
Slot Group
System Slot Table, 277
variable values, 281
SNMP
introduction to, 25
SNMP MIB OIDs, 26
SNMP security, 27
SNMP traps, 28
SNMP basic terminology
fields, 20-21
managed object, 20
MIB, 20
SNMP, 19
variable, 20
SNMP support,
configuring, 598
SNMP tables, 22
example, 22
reference guide content, 24,
28
SNMP traps, 599
Storage Management Event
Group, 554
Storage Management
Information Group, 463
System Resource Group
Direct Memory Access
Table, 121
Input/Output Port Table, 112
Interrupt Table, 118
Map Table, 107
Memory Table, 115
Owner Table, 109
variable values, 124
System State Table, 37, 277
systems management
software, 31
build number systems, 32
description name, 32
name, 32-34
preferred protocol, 33
supported protocol, 33
version number name, 32
traps, 572
AC power cord traps, 586
amperage probe traps, 579
chassis intrusion traps, 581
cooling device traps, 576
fan enclosure traps, 585
hardware log traps, 587
memory device traps, 584
miscellaneous traps, 573
power supply traps, 583
redundancy unit traps, 581
temperature probe traps, 574
understanding the trap
descriptions, 569
understanding trap
severity, 572
voltage probe traps, 577
U
User Security Table, 173, 175
V
T
Thermal Group
Cooling Device Table, 159
Cooling Unit Table, 157
Temperature Probe Table, 165
variable values, 169
trap variables, 567
current status, 568
data, 569
message, 568
previous status, 568
system, 568
table index OID, 568
variable names
capability, 21
settings, 21
state, 21
status, 21
Viewing
SNMP traps, 599
Index
635
636
Index
636
Index