INSTALLATION INSTRUCTIONS

AND OWNER'S MANUAL

The White Mountain Log Collection

LOG SET FOR UNVENTED

GAS LOG HEATER

OR

VENTED DECORATIVE APPLIANCE

MODELS

LS-18H-1

LS-24H-1

LS-30H-1

EFFECTIVE DATE

MAY 2006

WARNINGS

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

– Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any phone in your building.

• Immediately call your gas supplier from neighbor’s phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

– Installation and service must be performed by a qualified installer, service agency or the gas supplier.

20173-1-0506

INSTALLER: Leave this manual with the appliance.

CONSUMER: Retain this manual for future reference.

Log sets comply with ANSI Z21.11.2 Unvented

Heaters and also comply with ANSI Z21.60

Decorative Vented Appliances for Solid Fuel

Burning Fireplaces. State or local codes may only allow operation of log sets in a vented configuration.

Check your state or local codes.

WARNING: If not installed, operated and maintained in accordance with the manufacturer's instructions, this product could expose you to substances in fuel or from fuel combustion which can cause death or serious illness.

Page 1

TABLE OF CONTENTS

Section Page

Important Installation Guidelines ....................................................................................................................3

General Information ........................................................................................................................................3

Log Placement .................................................................................................................................................4

Ember Placement LS-18H-1 Photos ................................................................................................................5

Ember Placement LS-24H-1 Photos ................................................................................................................6

Ember Placement LS-30H-1 Photos ................................................................................................................7

Parts List & Parts View ....................................................................................................................................8

How to Order Repair Parts ..............................................................................................................................8

Page 2 20173-1-0506

IMPORTANT INSTALLATION GUIDELINES

Proper Log Placement

Log placement is critical to proper burner performance. Logs must be correctly positioned onto the burner. The photos in this manual show the proper pinned position for logs on this set.

Owners need to be shown proper log placement and instructed not to move the logs.

Logs must fit firmly onto the burner when positioned as shown in the photos. Malformed logs or logs with sloppy pin holes must be replaced.

Proper Placement of Rock Wool and Decorative Lava Rock

Rock wool can be added to burners for a glowing ember effect.

It must be positioned only on the front portion of the burner. The photos in this manual show the proper placement of rock wool.

Decorative lava rock or small wood pieces should never be placed on the burner. These items are only for placement on the floor of the fireplace or firebox.

Proper Primary Airflow into Burner

For proper burner operation and flame appearance, the flow of primary air into the venturi tube, located on the rear of the burner, must not be reduced. This flow of air is reduced if dirt, lint or other obstructions build-up around or inside the venturi. Any obstruction in the venturi tube area must be removed. The flow of air into the venturi is also reduced if the gas orifice isn’t centered in the venturi inlet and/or is not aligned with the venturi. Any misalignment of the burner orifice may be corrected by bending the shutter cap holding the orifice to the inlet of the venturi tube.

Ceiling Fans, Portable Fans or Logs Installed Near Cold Air

Returns

Ceiling fans or oscillating floor type fans need to be monitored during the operation of vent-free logs. If the air blows directly into the flame causing it to impinge on the log set, or firebox, it should be turned off or redirected. Ceiling fans could be reversed to possibly eliminate flame impingement, and the floor fan could be redirected. Upon installation, be aware of any cold air returns or vents in the proximity of the log set. Any draft created around a vent-free log set can cause the flame to impinge on the log and create a sooting situation.

WARNING: Do not allow fans to blow directly into the fireplace.

Avoid any drafts that alter burner flame patterns.

WARNING: Do not use a blower insert, heat exchanger insert or other accessory not approved for use with this heater.

Candles

Avoid the use of scented or decorative candles while the log set is in operation. Candles produce a residue in the air that creates a soot like substance. Burning candles while the log set is operating magnifies the problem. It should be noted that candles, in general, produce soot. The amount of time burned and the quantity of candles burned will determine the amount of soot produced and deposited.

Make Owners Aware of Proper Log Set Operation

Properly installed and properly maintained log sets do not deposit soot on the logs. If users see soot appear on a log, call for service.

Do not continue to operate the log set.

Sunken Fireplace

If installing this unit into a sunken fireplace, you must raise the floor to insure adequate airflow and guard against sooting. Raise fireplace floor using a non-combustible material, which is secure.

Glass Doors

Make sure that glass doors are open during all operations of the logset. The opening of the glass door frame should be the dimension used for the minimum front opening of the firebox.

Woodburning Fireplaces

The interior of the firebox and the chimney should be cleaned and free of all creosote before installing a gas burning log set. Creosote will soften when heated and can drop on the logset causing odors and possibly sooting.

WARNING: Before installing in a solid-fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner.

GENERAL INFORMATION

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment or accessories and repair and servicing of equipment shall be performed only by a qualified agency. The term "qualified agency" means any individual, firm, corporation, or company that either in person or through a representative is engaged in and is responsible for (a) the installation, testing, or replacement of gas piping or (b) the connection, installation, testing, repair, or servicing of equipment; that is experienced in such work; that is familiar with all precautions required, and that has complied with all the requirements of the authority having jurisdiction.

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1/

NFPA54.*

*Available from the American National Standards Institute, Inc. 11 West 42nd

St., New York, N.Y. 10018.

20173-1-0506

State of Massachusetts: The installation must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts.

Sellers of unvented propane or natural gas-fired supplemental room heaters shall provide to each purchaser a copy of 527

CMR 30 upon sale of the unit.

In the State of Massachusetts, unvented propane and natural gas-fired space heaters shall be prohibited in bedrooms and bathrooms.

Page 3

LOG PLACEMENT

Before you begin: Do not, handle these logs with your bare hands! Always wear gloves to prevent skin irritation. After handling logs, wash your hands gently with soap and water.

All Logs

The positioning of the logs is critical to the safe and clean operation of this heater. Sooting and other problems may result if the logs are not properly and firmly positioned in the appliance.

Refer to Figure 1 for the following warning.

Warning: Failure to position the parts in accordance with this diagram or failure to use only parts specifically approved with this appliance may result in property damage or personal injury.

PROPER INSTALLATION SEQUENCE:

LS-(18, 24, 30)H

(Figure 1)

1. Place rear (#2) log between rear log support and onto burner pan pins.

2. Place front (#1) log onto pins on burner pan.

3. Place top log (#3) onto (2 pins) front log.

4. Compare the completed log installation with the appropriate photo from pages 5 through 7. Review previous steps to make any necessary adjustments.

5. Log placement is completed.

Attention: Do not use Figure 1 to order replacement logs. Refer to

Page 8, Parts List and Parts View to order logs for your appropriate model number.

Apply loose material (glowing embers) per appropriate Installation

Instructions and Owner's Manual. Replacement of loose material

(glowing embers) must be purchased from Empire Comfort

Systems, Inc. Application of excess loose material (glowing embers) may adversely affect performance of the heater.

WARNING: All previously applied loose material must be removed prior to reapplication.

Replacement Loose Material (glowing embers) Part

Number

LS-18H

LS-24H

LS-30H

15999

15970

15970

Platinum Bright Embers PE-20-1

Note: A single layer of embers is to be used when applying

Platinum Bright Embers (alone or in combination with production embers) to the burner.

2

3

1

Log Placement

LS-(18, 24, 30)H Logs

Figure 1

The following WARNING applies when log set is installed onto an unvented gas burner assembly.

WARNING: This appliance is equipped for (natural or propane) gas. Field conversion is not permitted.

Page 4 20173-1-0506

EMBER PLACEMENT LS-18H-1 PHOTOS

20173-1-0506 Page 5

EMBER PLACEMENT LS-24H-1 PHOTOS

Page 6 20173-1-0506

EMBER PLACEMENT LS-30H-1 PHOTOS

20173-1-0506 Page 7

PARTS LIST AND PARTS VIEW

Attention: When ordering parts, it is very important that part number and description of part coincide.

Index No.

Part

Number Description

DEEP WOODS OAK LOG SETS

1 R-8319 FRONT LOG - 18"

1 R-8323 FRONT LOG - 24"

1

2

R-8326

R-8320

FRONT LOG - 30"

REAR LOG - 18"

2

2

3

3

3

R-8324

R-8327

R-8321

R-8325

R-8328

REAR LOG - 24"

REAR LOG - 30"

TOP LOG - 18"

TOP LOG - 24"

TOP LOG - 30"

2

3

1

USE ONLY MANUFACTURER'S REPLACEMENT PARTS. USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH.

HOW TO ORDER REPAIR PARTS

Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the service person/dealer.

All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number from the name plate on your equipment. Then determine the Part Number (not the Index Number) and the Description of each part from the following appropriate illustration and list. Be sure to give all this information . . .

Appliance Model Number

Appliance Serial Number

Part Description

Part Number

Type of Gas (Propane or Natural)

Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store.

Shipments contingent upon strikes, fires and all causes beyond our control.

Empire Comfort Systems, Inc.

918 Freeburg Ave. Belleville, IL 62220

PH: 618-233-7420 or 800-851-3153

FAX: 618-233-7097 or 800-443-8648 [email protected]

www.empirecomfort.com

Page 8 20173-1-0506

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals