Operating Instructions
Digital Video Recorder
Models: DTR-6008/250CD, DTR-6016/250CD,
DTR-6008/500CD, DTR-6016/500CD,
DTR-6008/750CD DTR-6016/750CD
Safety instructions
EMC class
► This video recorder (DVR) is a class A device in accordance with EN 55022.
► This device may cause interference to other equipment in domestic use. In such cases the persons operating the DVR are required to provide appropriate countermeasures, for which they themselves bear the cost.
Importance of these Operating Instructions
► Please read the safety instructions and the other information contained in the Operating Instructions before
connecting up and operating the DVR.
► The Operating Instructions should be kept in a safe place for later reference.
Ambient conditions for the DVR
► The DVR should be protected against excessive heat, dust, damp and vibration.
► The DVR may only be operated at temperatures between +5°C and +40°C, and up to a maximum air
humidity of 90%.
► The DVR may only be operated indoors, and must be protected against incursion of water and damp.
Care of the DVR
► Never switch on the DVR when damp has penetrated it. In such cases, have the DVR checked by a qualified
service engineer.
► Do not place any heavy objects on the DVR.
► Never cover over the DVR's vents.
► Never insert metal objects or any other items into the vents. This may permanently damage the DVR.
► The housing may only be opened by authorised persons. Repairs may only be carried out by qualified
service personnel.
► The DVR must be disconnected from the power supply before its housing is opened.
Getting started with the DVR
► When laying the connecting cables, make sure no weight is placed on them, that they are not kinked or
damaged, and that no damp can penetrate them.
Cleaning the DVR
► The housing of the DVR may only be cleaned with a damp (not wet) cloth,
► Use only a mild detergent. Do not use solvent-containing detergents or petrol. This could permanently
damage the surface finish.
Spare parts
► Use only original spare parts from Videor Technical E. Hartig GmbH.
DTR-60XX
Table of contents
Overview
Package contents
Basic functions
Features
Requirements for operation
Control options
Connections on the rear
Front panel controls
Key to controls
Function buttons
PTZ camera functions
Playback functions
Remote control functions
Playback functions
Menu overview
Accessing the menus
Accessing the Display menu
Accessing the PTZ menu
Accessing the Setup menu
Accessing the Search menu
Getting started
Checklist for DVR operation
Connecting the remote control and DVR
Switching on the DVR
Switching off the DVR
Administration
Saving your system setup Loading your system setup
Deleting recordings
Downloading software updates
Hiding from specific users
Restoring factory defaults
Mirroring of hard disks
Determining the memory requirement of a recording
Searching for recordings
Using calendar search
Using event log search
Using text-in search
Using motion search
Copying recordings
DTR-60XX
7
7
7
7
7
7
8
9
10
10
10
10
11
11
12
14
14
14
15
15
16
16
16
17
17
18
18
18
18
19
19
19
20
21
22
23
24
25
26
27
Table of contents
Menu descriptions – Setup menu
28
System – Information
29
System – Date/Time30
System – Storage31
System – User33
System – Shutdown34
System – Log out user1...34
Network – Network34
Network – Notification
37
Devices – Camera38
Devices – Audio39
Devices – Alarm-Out
40
Devices – Display
41
Devices – Remote Control
42
Record – Record
43
Record – Schedule
44
Record – Pre-Event
45
Record – Archive
46
Event – Alarm-In
47
Event – Motion Detection
49
Event – Video Loss
51
Event – Text-In
53
Event – System Event
55
Event – Event Status
57
WebGuard – WebWatch controls
58
WebGuard – WebSearch controls
59
Using WebGuard
60
Specifications DTR-6008
61
Specifications DTR-6016
63
Accessories
65
Supported PTZ cameras
66
Index
67
Notes on disposal
70
DTR-60XX
Overview
Package contents
●
●
●
●
●
●
●
●
●
Digital video recorder (DVR)
Mains power cord
Operating instructions
RAS (Remote Administration System) software on CD
Operating instructions for RAS software on paper and CD
Mounting kit for cabinet installation
Screws for attaching SCSI Connector
Mounting screws and guides for installation of hard disk drives
Infrared remote control
Basic functions
●
●
●
●
Record video images using multiple cameras
Even-based recording start
Video playback
Search for specific video sequences
Features
●
●
●
●
●
●
●
●
●
●
●
●
●
MPEG-4 compression / triplex mode
8 or 16 loop-through inputs / VGA, S-VHS/FBAS outputs
Audio and alarm inputs / outputs
Max. recording speed DTR-6008/xxxCD: 200 field images per sec (PAL) / D1: 50 field images per sec (PAL)
Max. recording speed DTR-6016/xxxCD: 400 field images per sec (PAL) / D1: 100 field images per sec (PAL)
Memory capacity 250 GB / 500 GB / 750 GB
Maximum video resolution 720 x 576 pixels
SCSI port for archiving / memory expansion
Various recording criteria possible
Archiving/image transfer via USB and CD-RW
ATM/POS text display / 2x to 4x digital zoom
Telemetry control functions via RS-485 port
Network port (Ethernet) / IR remote control
Requirements for operation
●
●
●
●
Digital video recorder DTR connected
At least 1 camera connected
At least 1 monitor connected
Mouse connected, if DVR is to be controlled by mouse
Control options
●
●
●
●
●
Front panel
Remote Control
Mouse
WebGuard
RAS program
DTR-60XX
Connections on the rear
Note: Connections optionally for NTSC or PAL operation.
1
2
4
5
6
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
VIDEO OUT
SPOT 1
SPOT 2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
SVHS OUT
SPOT 3
SPOT 4
VIDEO IN
LOOP
AUDIO IN 1
AUDIO IN 2
AUDIO IN 3
AUDIO IN 4
AUDIO OIT
AI1 AI2 AI3 AI4 GND AI5 AI6 AI7 AI8 GND AI9 AI10 AI11 AI12 GND AI13 AI14 AI15 AI16 GND
NC COM NO AO2 AO3 AO4 AO5 AO6 AO7 AO8 GND AO9 AO10 AO11 AO12 AO13 AO14 AO15 AO16 GND
ARI GND
RS-485
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
19
18
17
USB
16
15
14
1
RS-232C
12
VGA
11
SCSI
10
9
NETWORK
8
No.
Designation
Functions/connections
Example devices
1
VIDEO IN 1-16
Max. 16 video channels
Cameras
2
LOOP 1-16
Max. 16 loop-through video channels
Cameras
3
SVHS OUT
S-VHS output
Monitors
4
VIDEO OUT
Video output
Monitors
5
SPOT1 - SPOT4
Max. 4 video outputs
Spot monitors
6
RS-485
External interface
Keyboard, PTZ camera
7
NETWORK
Network
Network cable
8
ARI/GND
Reset alarm with external signal
Switch
9
SCSI
External storage media
Hard disk
10
AO2 - AO16
Alarm outputs for external devices
Siren, flashing light
11
VGA
PC monitor
PC monitor
12
NC, COM, NO
Relay alarm output for external device
Siren, flashing light
13
RS-232C
External interface
Modem
14
USB
External interface
Drive, mouse
15
Reset switch
Reset to factory defaults
-
16
AI1 - AI16
Alarm inputs for external devices
Sensors
17
AUDIO OUT
Audio output
Amplifier, speakers
18
AUDIO IN 1
- AUDIO IN 4
Max. 4 Audio inputs
Microphone
19
Power supply
Mains power connection
-
7
DTR-60XX
Front panel controls
The following diagram and table set out the controls on the front panel of the DVR:
1
2
1
4
2
3
4
5
5
6
7
6
8
PANIC
JOG
CAMERA
9
10
11
12
DISPLAY
SEQUENCE
FREEZE
SPOT
MENU
ALARM
ZOOM
PTZ
13
14
15
SEARCH
PLAY/PAUSE
RW
FF
BACKWARD
FORWARD
16
HDD
NETWORK
14
No.
Designation
1
12
POWER
11
10
9
8
7
Function
1
USB ports
2
Open built-in CD-RW writer
3
1 to 16
● Select cameras
● Enter passwords
4
Menu navigation
Navigation and selection within the menu
5
PANIC
Start/end panic recording
6
Shuttle ring
Infinitely adjust playback speed
7
Jog dial
● Change size of frame in picture-in-picture mode
● Change numerical values in Setup menu
● Frame-by-frame playback in Play mode
Playback functions (primary assignment)
8
PTZ camera functions (secondary assignment)
9
POWER
Power-on indicator when DVR is in operation
10
NETWORK
Indicates Ethernet or modem connection
11
HDD
Indicates hard disk operation
12
DISPLAY, SEQUENCE,
FREEZE, SPOT, ZOOM,
PTZ
Function buttons
13
ALARM
● Reset alarm
● View event list
14
MENU
Open/quit menu structure
DTR-60XX
Key to controls
Function buttons
Element
Function
Change display mode
Sequence On/Off
● Freeze On/Off
● Copying recordings in Search menu by pressing and holding down button
Spot monitor assignments
PTZ camera functions On/Off
Zoom On/Off
PTZ camera functions
Element
Function
Zoom in
Zoom in
Close-up
Wide-angle
Save preset
Load preset
Playback functions
Element
Function
● Select Search/Play function
● Stop playback
Start/pause playback
Fast rewind
Fast forward
Frame-by-frame rewind
Frame-by-frame forward
10
DTR-60XX
Remote control functions
The following diagram and table set out the functions on the remote control:
Select System ID
ID
SPOT
1
2
DISPLAY
SEQUENCE
12
11
3
4
FREEZE
ALARM
CAMERA
1
2
3
5
6
7
8
9
10
11
12
15
16
13
14
TRIPLEX
AUDIO
4
FOCUS
2
BOOK MARK CLIP COPY
4
SET
10
1
PRESET
ZOOM
VIEW
MENU
9
PTZ
5
ZOOM
PANIC
6
8
DIGITAL VIDEO RECORDER
Remote Controller
7
No.
Designation
Function
1
SPOT 1 - 4
Spot monitor assignments
2
ALARM
● Reset alarm
● View event list
3
1 to 16
● Select cameras
● Enter passwords
4
PTZ camera functions
5
PTZ
PTZ camera functions On/Off
6
ZOOM
Zoom On/Off
7
Playback functions
8
PANIC
Start/end panic recording
9
Menu navigation
Navigation and selection within
the menu
10
MENU
Open/quit menu structure
11
12
No function
DISPLAY, SEQUENCE,
FREEZE
Function buttons
Playback functions
Element
Function
● Select Search/Play function
● Stop playback
Pause playback
Start playback
Fast rewind
Fast forward
Frame-by-frame rewind
Frame-by-frame forward
DTR-60XX
11
Menu overview
The following illustration shows the structure of the complete menu tree that is accessible using the mouse
control:
Display
Camera
1. CAM1
2. CAM2
3. CAM3
PIP
Left-Top
Left-Bottom
Right-Top
Right-Bottom
Size 1/16
Size 1/9
Size 1/4
2x2
3x3
4x4
Previous Group
Next Group
Edit Group
Sequence
Freeze
Zoom...
PTZ...
Spot Monitor...
12
Camera
Spot Monitor...
Exit Group Edit
Speed
Auto Pan
Tour
Pattern
Device Menu
Light
Pump
Wiper
Power
Aux.
Move to Origin
Spot Monitor...
Toggle VGA...
Exit PTZ
Select Spot Monitor
Spot Monitor 1
Spot Monitor 2
Spot Monitor 3
Spot Monitor 4
DTR-60XX
Menu overview (continued)
The following illustration shows the structure of the complete menu tree that is accessible using the mouse
control:
Setup Menu...
Search
System
Information
Date/Time
Storage
User
Shutdown...
Log out user1...
Network
Network
Notification
Devices
Camera
Audio
Alarm-Out
Display
Remote Control
Record
Record
Schedule
Pre-Event
Archive
Event
Alarm-In
Motion Detection
Video Loss
Text-In
System Event
Event Status
Go to the First
Go to the Last
Go to the Date/Time...
Calendar Search...
Event Log Search...
Text-In Search…
Motion Search...
Clip-Copy...
Print...
Zoom...
Slow Play
Data Source
Exit Search
DTR-60XX
x1
x1/2
x1/3
x1/4
x1/6
x1/8
Record
Archive
13
Accessing the menus
Accessing the Display menu
Requirement:
● The current camera image is shown in full image or quad image.
Step
Action
1
Open Display menu...
Access using
Key sequence/menu
path
Device
Remote Control
Mouse
Display
Access to submenu via Device/Remote Control
Submenu
Camera image
Change Display modes (PIP, 2x2, 3x3, 4x4)
Without frame
Key sequence
Previous/Next Group
Without frame
Edit Group
With frames
Change position of image-in-image
Without frame
Change size of image-in-image
Without frame
Jog dial
Action
Access using
Key sequence/menu
path
Open PTZ menu...
Device
Result: Menu of the configured PTZ
camera is shown.
Remote Control
PTZ
Mouse
PTZ...
....
>
Accessing the PTZ menu
Requirement:
● A PTZ camera is connected and configured.
● Current camera image is shown as a full image.
Step
1
14
>
>
MENU
DTR-60XX
Accessing the menus, continued
Accessing the Setup menu
Requirement:
● The current camera image is shown in full image or quad image.
Step
1
2
Key sequence/menu
path
Action
Access using
Open Setup Menu...
Device
Result: Prompt for user name and
password.
Remote Control
MENU
Mouse
Setup Menu...
Log in as user.
User name: admin
Password: (blank)
Note: Use default access data only for
first-time access.
Accessing the Search menu
Requirement:
● The current camera image is shown in full image or quad image.
Step
1
DTR-60XX
Action
Access using
Open Search menu...
Device
Result: Search for recorded images is
activated.
Mouse
Remote Control
Key sequence/menu path
>
>
MENU
Search
15
Getting started
Checklist for DVR operation
Step
Action
Menu path
1
Connect peripheral devices as per planned setup.
2
Specify menu language.
Setup Menu... > System > Information
3
Adjust date and time.
Setup Menu... > System > Date/Time
4
Set up user.
Setup Menu... > System > User
5
Set up network and desired notification channels
(optional).
Setup Menu... > Network > ...
6
Register peripherals with DVR.
Setup Menu... > Devices > ...
7
Set up event types and associated responses.
Setup Menu... > Event > ...
8
Set up recording parameters and schedule.
Setup Menu... > Record > ...
Connecting the remote control and DVR
The remote control and DVR can be assigned an ID, because the ID of each DVR in the network must be
unique. The DVR will then only respond to the remote control with the matching ID.
● If the system ID in the DVR is 0, it will respond to the remote control regardless of the remote’s ID.
● If the system ID in the DVR is not 0, you must set the ID of the remote control identically.
Step
Action
Menu path
1
Set DVR system ID.
Setup Menu... > System > Information
2
Match remote control to system ID by
pressing ID button on remote control.
3
Select relevant number on remote control.
16
DTR-60XX
Getting started (continued)
Switching on the DVR
Requirement:
● The start-up preparations are complete.
Step
Action
1
Plug in DVR mains plug.
2
Switch on monitor.
Result: System starts up automatically and is ready to use.
Switching off the DVR
Requirement:
● You have accessed the Setup menu.
Step
1
2
DTR-60XX
Action
Shut down the system.
Result: System shuts down automatically.
Menu path
Setup Menu... > System > Shutdown...
After shutdown, disconnect the mains plug.
17
Administration
Saving your system setup
You can save your DVR’s setup data, including its network configuration.
Requirement:
● USB memory stick
Step
Action
1
Insert a USB memory stick into one of the USB
ports.
2
Export your setup.
3
Specify a file name.
4
Export your setup.
Menu path
Setup Menu... > System > Information >
Setup > Export...
Export
Loading your system setup
You can load your stored DVR system setup with or without its network configuration.
Requirement:
● USB memory stick with stored setup
Step
Action
Menu path
1
Insert a USB memory stick into one of the USB
ports.
2
Import your setup.
3
Select the file name and, where appropriate, the
network configuration.
4
Import your setup.
Setup Menu... > System > Information >
Setup > Import...
Import
Deleting recordings
You can only delete all your recordings together. It is not possible to delete recordings from a specific time
period.
Step
1
18
Action
Menu path
Delete all recordings.
Setup Menu... > System > Information > Clear All
Data...
or
Setup Menu... > System > Storage > Information >
Information > In Use > Clear
DTR-60XX
Administration (continued)
Downloading software updates
You can download software updates for your DVR from a USB memory stick.
Requirement:
● USB memory stick with latest software release
Step
Action
1
Insert a USB memory stick into one of the
USB ports.
2
Start update.
3
Install new release.
Menu path
Setup Menu... > System > Information > Upgrade...
Hiding from specific users
You can hide video images and camera data according to the preset user rights.
Step
Action
Menu path
1
Set camera Covert mode.
Setup Menu... > Devices > Camera > Settings
2
Cancel ‘Covert Camera View' access for
specific users (groups).
Setup Menu... > System > User
Restoring factory defaults
Before restoring the factory defaults, you should export your current system settings in case you need to reimport them later. (see Saving your system setup and Loading your system setup)
Step
Action
1
Shut down the system.
2
Disconnect the mains plug.
3
Push a paper clip into the Reset button (on the rear of the DVR) and hold it there.
4
Plug in the mains plug.
5
Wait for all the LEDs to flash 5 times (about 30 seconds).
6
Withdraw the paper clip.
DTR-60XX
19
Administration (continued)
Mirroring of hard disks
Mirroring of hard disks prevents the loss of records in the event of a hard disk defect.
Requirements:
● The Digital Video Recorder has at least 2 or 3 hard disks installed
● The destination hard disk is identical to the source hard disk in type and memory capacity
● The source-hard disk and the destination hard disk are not used for archiving records.
Step
Action
Menu path
1
Formatting the source hard disk for recording.
Setup Menu... > System > Storage>
Information > Format > Record
2
Select the source hard disk.
Setup Menu... > System > Storage>
Information > Mirror 1/2 > Source
3
Select the destination hard disk.
Setup Menu... > System > Storage>
Information > Mirror 1/2 > Dest.
Start Mirroring.
Results:
4
Start...
● The source hard disk and destination hard disk are
synchronised (approx. 40 minutes for 10 GB).
● All data on the destination hard disk are deleted.
● All records are written to both hard disks.
Interrupting Mirroring.
Results:
5
6
20
● The status of the destination hard is set to:
Stop...
Don't use
● The hard disk can now only be used for searching
for records.
● If the hard disk is to be used for records or archiving,
it must be formatted.
Setup Menu... > System > Storage>
Information > Format > Format
Continuing Mirroring - see Starting Mirroring.
Start...
DTR-60XX
Administration (continued)
Determining the memory requirement of a recording
The amount of memory recorded video sequences will take up depends on the following factors:
● Picture quality
● number of images per second
● duration
The memory requirement is calculated by this formula:
Memory requirement = picture size x duration of recording x images per second
Calculation example: CIF resolution (PAL):
Picture
quality
Picture
size
Duration of
recording
Basic
2.4 kB
Standard
4.8 kB
High
Very High
Approx. memory space
5 images/s
10 images/s
25 images/s
24 hours
1.04 GB
2.07 GB
5.18 GB
24 hours
2.07 GB
4.15 GB
10.37 GB
9.6 kB
24 hours
4.15 GB
8.29 GB
20.74 GB
14.4 kB
24 hours
6.22 GB
12.44 GB
31.10 GB
2Calculation example: 2CIF resolution (PAL):
Approx. memory space
Picture
quality
Picture
size
Duration of
recording
5 images/s
10 images/s
25 images/s
Basic
4.8 kB
24 hours
2.07 GB
4.15 GB
10.37 GB
Standard
9.6 kB
24 hours
4.15 GB
8.29 GB
20.74 GB
High
19.2 kB
24 hours
8.29 GB
16.59 GB
41.47 GB
Very High
28.8 kB
24 hours
12.44 GB
24.88 GB
62.20 GB
DTR-60XX
21
Searching for recordings
Find first stored recording
Search
Go to the First
Find last stored recording
Search
Go to the Last
Find recording by date and time
Search
Go to the Date/Time...
Calendar search
For each camera the calendar search indicates:
● the days from which there are recordings
● the time ranges of recordings on those days
Search
Calendar Search...
Event log search
The event log search enables you to search for events based on specific criteria, such as:
● movements recorded by a specific camera
● alarm from a specific alarm input
● System events
Search
Event Log Search...
Text-in search
The text-in search enables you to search for recordings based on specific text inputs.
Search
Text-In Search…
Motion search
The motion search function can detect movements in recordings within defined zones for one camera. 2 types
of motion search are possible:
● Motion search: Search for movement in a defined zone.
● Museum search: Search for movement of a defined object.
Search
Motion Search...
Copying recordings
Recordings can be written to a CD or copied to a USB memory stick.
Search
22
Clip-Copy...
DTR-60XX
Using calendar search
Performing a calendar search
Step
1
Action
Menu path
Open calendar search.
Result: Calendar and time line are displayed.
2
Select day and time
3
Confirm input.
Search
Term
Search > Calendar Search...
Go
Calendar Search...
Symbol
Meaning
Date display
● Grey: No recording available
● White: Recording available
Hours display
● White: Recording available
Select a Segment
DTR-60XX
If the date and time on the DVR have been changed (such
as when switching to Summer time) there may be multiple
recordings for one time from the same camera. They are stored
in separate segments.
23
Using event log search
Performing an event log search
Step
1
2
3
4
Action
Menu path
Open event log search.
Result: The result of the last search is displayed.
Define criteria.
Search > Event Log Search...
Option...
Confirm input.
Result: List of search results is displayed.
Search
Select desired entry from list.
Search
Term
Event Log Search...
Symbol
Option...
Meaning
From First
Start date
To Last
End date
Check Time Overlap
Activates a system prompt if there are multiple recordings
for the same time range
Alarm-In
Alarm inputs in response to which a search for events is
to start
Motion
Cameras on which to search for motion detection
Video Loss
Cameras on which to search for video loss
Text-In
Text input devices on which to search for events
Record Channels
Cameras on which to search for events
Search for system events:
Setup Menu... > Event > System Event > Actions
24
DTR-60XX
Using text-in search
Performing a text-in search
Step
1
2
3
4
Action
Menu path
Open text-in search.
Result: The result of the last search is displayed.
Define text inputs.
Search > Text-In Search...
Option...
Confirm input.
Result: List of search results is displayed.
Search
Select desired entry from list.
Search
Term
Text-In Search…
Symbol
Option...
Meaning
From First
Start date
To Last
End date
Channels
Text input devices on which to search for events
Type of text input:
Any Text-In Product
Generic Text
Epson
No.
Numbers of text elements to search for
Keyword
Text element
Case Sensitive
Makes search case-sensitive
DTR-60XX
25
Using motion search
Performing a motion search
Step
Action
Menu path
1
Display desired camera in single frame.
Display > Camera > ...
2
Open motion search.
Search > Motion Search...
3
Enter settings for motion search.
Option...
4
5
Search
Term
Confirm input.
Search
Result: List of search results is generated.
Select desired entry from list.
Motion Search...
Symbol
Option...
Meaning
From First
Start date
To Last
End date
Type of search:
Type
Zone
Motion Search
Search for movement in a defined zone
Museum Search
Search for movement of a defined object.
Definition of motion-sensitive zones for motion search or museum
search: See “Zone” on page 46.
Sensitivity of motion detection of:
1 (Dull)
Sensitivity
2
3
4
5 (Sensitive)
Min. Blocks
26
Motion search only (not museum search):
Specify in how many motion-sensitive blocks motion must be detected
as a minimum to trigger an alarm
DTR-60XX
Copying recordings
Copying recordings to CD or USB memory stick
Step
1
2
3
Search
Term
Data Source
Action
Menu path
Find desired recordings.
Note: Make a note of the data of the recordings you
want to copy.
Search > ...
Define settings.
Search > Clip-Copy...
Start copying.
Result: The recordings are copied.
Start
Clip-Copy...
Symbol
Meaning
Record
From First
Start date
To Last
End date
Channels
Assignment of cameras from which recordings are to be copied
Password
Use password, if desired
Destination medium:
Internal DVD-RW
Dest.
USB-CD-RW
1. USB Storage
2. USB Storage
3. USB Storage
File name
Name of file on destination medium
Status
Copy status
DTR-60XX
27
Menu descriptions – Setup menu
The Setup menu has the following sub-menus:
System menu
On the “System” menu
● the basic settings are made
● users are administered
● the system is shut down.
Network menu
On the “Network” menu the network settings are made. Network access provides
access to all the functions of the DVR via
● WebGuard, same access using Internet Explorer
● RAS (Remote Administration System), independent of Internet Explorer
The DVR can be configured so that alarms trigger a notification by e-mail or notify an
RAS.
Devices menu
On the “Devices” menu the connected peripheral devices are configured. Possible
peripherals are:
● Cameras
● Microphones and speakers (through amplifier)
● Sirens and signal lamps
● Monitors
● Remote control for PTZ
Record menu
On the “Record” menu the following settings are made:
● Recording quality
● Timer control
● Duration of pre-event recording
● Schedule and method of archiving
Event menu
On the “Event” menu the following settings are made:
● Assignment of alarm inputs to alarms
● Configuration of motion-sensitive zones individually for each camera
● Definition of text input device and assignment to alarms
● Response to undesirable events
The event status is additionally displayed.
28
DTR-60XX
Setup menu
System – Information
On the “Information” menu
● basic information is entered and displayed
● software updates are installed
● recorded data are deleted as required
Setup Menu...
Term
System
Symbol
Information
Meaning
Site
Location of DVR
System ID
Identifier for remote control
● The remote control and DVR must be set to the same ID.
● If the system ID in the DVR is 0, it will respond to the remote
control regardless of the remote’s ID.
Language
Menu language
Version
Version of DVR software
Upgrade...
Starts installing latest version of software via USB port
Import...
Import setup
Export...
Export setup
Show System Log...
Show log of all actions and events
Recorded Data
From
Date of oldest recording
To
Date of newest recording
Clear All Data...
Deletes all stored data
DTR-60XX
29
Setup menu (continued)
System – Date/Time
On the “Date/Time” menu
● time and date settings are made
● dates of public holidays are entered
● time synchronisation is configured.
Setup Menu...
Term
System
Symbol
Date/Time
Date/Time
Meaning
Date
Date
Format Date display format
Time
Time
Format Time display format
Time Zone
Local time zone
Use Daylight Saving Time
Activates use of summertime Daylight Saving Time
Setup Menu...
Term
System
Symbol
Date/Time
Holiday
Meaning
No.
Number of entered public holiday
Date
Date of each desired public holiday
Setup Menu...
Term
System
Symbol
Date/Time
Time Sync
Meaning
Automatic Sync.
Activates synchronisation with time server
Time Server
IP address of time server
Interval
Synchronisation interval
Last Sync-Time
Time of last synchronisation
Run as Server
Activates use of the DVR as the time server
30
DTR-60XX
Setup menu (continued)
System – Storage
On the “Storage” menu the status and usage of the available storage media is displayed.
Setup Menu...
Term
System
Symbol
Storage
Information
Meaning
Type
Type of storage medium
Capacity
Size of storage medium
Format Storage medium usage >>
Information
Time range of recorded data >>
Mirror 1/2
Source
Source hard disk
Dest.
Destination hard disk
Start...
Starts the Mirroring
Format
Term
Symbol
Meaning
Use of storage medium:
Use as
Record
Archive
Not using
Activating permits:
Partition
Format DTR-60XX
DVD burn
Reserves a data buffer as a separate
partition. This is essential for burning
DVDs, and must be activated for a
storage medium with „Record“ usage.
Formatting deletes the recordings from the hard disk
31
Setup menu (continued)
Information
Term
Symbol
Meaning
Recorded Data
From
Start date of recorded data
To
End date of recorded data
Clear
Delete all recordings
Setup Menu...
Term
System
Symbol
Storage
Meaning
Type
Memory type
Disk Bad
Data carrier status
Temperature
Temperature status
S.M.A.R.T.
Result of S.M.A.R.T. check
32
Status
DTR-60XX
Setup menu (continued)
System – User
On the “User” menu the user groups and individual users are set up.
Setup Menu...
Term
System
Symbol
User
Meaning
Group & User
Group field
Assignment of group access privileges
Table of possible group access privileges >>
Group & User
User field
Set password
+ Group...
Add a new group
+ User...
Add a new user
Set password
Auto Login
User to be logged in automatically
Auto Logout
Time after which logged-in user is automatically logged out
Table of possible group access privileges
Group access privilege
Meaning
Shutdown
May shut down the DVR
Upgrade
May install a new firmware version
System Time Change
May change the time setting
Data Clear
May delete recording data
Setup
May make changes anywhere on the Setup menu
Colour Control
May change the picture settings
PTZ Control
May control PTZ cameras
Alarm-Out Control
May reset alarms
Covert Camera View
May view video images from covert cameras
System Check
May interrogate system status
Record Setup
May make changes to the Record menu
Search
May use Search mode
Clip-Copy
May copy video images
DTR-60XX
33
Setup menu (continued)
System – Shutdown
Setup Menu...
System
Shutdown...
System – Log out user1...
Setup Menu...
System
Log out user1...
Network – Network
On the “Network” menu all settings required to ensure network access are made.
Setup Menu...
Term
Network
Symbol
Network
Network
Meaning
Transmission bandwidth:
Transfer Speed
(bps)
bits per second
(ips)
images per second
Quality of picture transmission via network (PAL):
Quality
Very High
14,4 kB/picture
High
9,6 kB/picture
Standard
4,8 kB/picture
Basic
2,4 kB/picture
Selecting Audio Channel
Remote Audio Channel
Select From RAS
1-4
34
DTR-60XX
Setup menu (continued)
Setup Menu...
Term
Network
Symbol
Network
LAN
Meaning
Type of connection to DVR:
Type
Manual
Manual connection required input of:
● IP Address
● Gateway
● Subnet Mask
DHCP
Automatic assignment of IP address of DNS
server
ADSL
(with
PPPoE)
Requires following input as specified by provider:
● ID
● Password
Note: Use of modem must not be activated.
DNS Server
Address of DNS server
Port Number Setup...
Definition of port numbers needed to access the DVR via the
RAS software or via WebGuard
Setup Menu...
Term
Enable
Network
Symbol
Network
Meaning
Enables modem use
Note: LAN type ADSL must not be enabled.
Baud Rate
Baud Rate
Data Bit
Number of data bits
Stop Bit
Number of stop bits
Parity
Parity
DTR-60XX
Modem
35
Setup menu (continued)
Setup Menu...
Network
Term
Network
Symbol
DVRNS
Meaning
Use DVR Name Service
Enables the DVR name service
DVRNS Server
IP address or domain name of DVRNS server
DVRNS = Digital Video Recorder Name Service
Port
Port for DVRNS
Use NAT
Enables NAT (Network Address Translation) use
DVR Name
Name by which the DVR is to be registered with the DVRNS
server
Check
Check DVR name for usability after entering
Help Desk
Information from help desk if DVRNS setting correct
Setup Menu...
Term
Network
Network
Symbol
WebGuard
Meaning
Use WebGuard Service
WebGuard Service activated
Port
Port for the WebGuard Service
36
DTR-60XX
Setup menu (continued)
Network – Notification
On the “Notification” menu the method of notification is defined.
Setup Menu...
Term
Network
Symbol
Notification
Meaning
Enable
Enables notification by e-mail
SMTP Server
IP address of SMTP server
Port
Port for SMTP server
Default is port 25.
Use SSL/TLS
Activates the Encryption
Authentication
Login to SMTP server
Sender
E-mail address of sender
Recipient
E-mail address of recipient
Setup Menu...
Term
Network
Symbol
Mail
Notification
Callback
Meaning
LAN
Enables notification of an RAS via LAN
No.
Number of IP address
IP Address
IP addresses of RAS PCs
Retry
Number of notification attempts by the DVR in the event of an
error
Modem
Enables notification of an RAS via modem
Remote Server Phone
Number
Telephone number of the modem on the notified RAS PC
Outside Line Call
Outside line code for external calls, if DVR’s modem is connected to a PABX system
Callback Phone Number
Telephone number of DVR’s modem
The RAS PC contacts the DVR on this number.
DTR-60XX
37
Setup menu (continued)
Devices – Camera
On the “Camera” menu the cameras are configured.
Setup Menu...
Term
Devices
Symbol
Camera
Settings
Meaning
No.
Activates the cameras
Title
Name of camera
Visibility of recordings and camera data depending on user access
privileges:
Use
Normal
All users see all camera data and all recordings
Covert 1
Users without relevant access see camera title, status
symbol, but no recordings
Covert 2
Users without relevant access see only camera title, but no
recordings
Quality of recorded images
Resolution
Setup Menu...
Term
Standard
CIF
High
2CIF
D1
D1
Devices
Symbol
Camera
PTZ
Meaning
No.
Number of camera
Product
PTZ camera type as per specified list
ID
Unique ID of PTZ camera
Port
Interface type of PTZ cameras
Settings as specified by PTZ camera manufacturer:
Baud Rate
Setup…
Data Bit
Stop Bit
Parity
38
DTR-60XX
Setup menu (continued)
Devices – Audio
On the “Audio” menu the audio outputs are assigned to the cameras.
Setup Menu...
Term
Devices
Symbol
Audio
Meaning
No.
Number of audio output
Associated Camera
Assignment of camera
Enable Audio-Out
Enables all audio outputs
DTR-60XX
39
Setup menu (continued)
Devices – Alarm-Out
On the “Alarm-Out” menu the alarm outputs are configured.
● “Settings” tab: The alarm outputs are configured.
● “Schedule” tab: Time slots are defined in which the alarm outputs respond in specific ways.
Setup Menu...
Term
Devices
Symbol
Alarm-Out
Settings
Meaning
No.
Number of alarm output
Title
Name of alarm output
Contact method of alarm output:
Type
Dwell
Setup Menu...
Term
NO
Normally Open
NC
Normally Closed
Duration of alarm signal
Devices
Symbol
Alarm-Out
Schedule
Meaning
No.
Number of schedule entry
Day
Day of the week
Range
Time range at 15-minute intervals
Response in defined period:
Mode
Channels
40
Event
Alarm in response to event
On
Continuous alarm
Off
No alarm
Enable
● Alarm outputs
● internal beep by DVR
DTR-60XX
Setup menu (continued)
Devices – Display
On the “Display” menu the mode of on-screen display is configured.
● “OSD” tab: Specify what additional information is displayed on-screen.
● “Main Monitor” tab: Specify how the camera images are displayed on the main monitor.
● “Spot Monitor” tab: Specify which cameras are displayed on the spot monitors.
Setup Menu...
Term
Devices
Symbol
Display
Displayed symbol
OSD
Meaning
Status
Activates display of:
Remote Control
Remote Control
Zoom
Visible when Zoom mode enabled
Network
Visible when DVR operating in a network
Freeze & Sequence
● Freeze
● Visible when Sequence mode enabled
Screen Group
1/4
Displays number of groups, and their ID
numbers
● Visible when Recycle mode enabled
● Remaining hard disk capacity, if Recycle
mode not selected
Free Space
Archive
Visible when archiving in progress
Date
-
Date
Time
-
Time
User Name
-
Display of user name
Camera
Activates display of:
No.
-
Display of camera number
Title
-
Display of camera title
Record
Display of Record symbols
Audio
Audio
PTZ
Visible when PTZ camera is displayed
Text-In
-
Display of character string
Transparency
-
Transparency of menu screens
OSD Margin...
-
Distance of displayed symbols from screen
margin
DTR-60XX
41
Setup menu (continued)
Setup Menu...
Term
Devices
Symbol
Display
Main Monitor
Meaning
Modes of sequences in multiple playback:
Mode
Full
Sequence
All cameras are switched through sequentially.
Cameo
Sequence
Only the image at the bottom right is switched
through; cameras in „Covert“ mode are not
displayed to users without „Covert“ access.
Interval
Time interval between picture refresh
Event Monitoring On
Displays image of relevant camera in full-screen mode when an
event occurs
Setup Menu...
Term
Devices
Symbol
No.
Display
Spot Monitor
Meaning
Number of spot monitor output
Channels
Camera
Selecting a camera
Dwell
Duration of display of the camera image
Devices – Remote Control
On the “Remote Control” menu the remote control function is configured.
Setup Menu...
Term
Port
Devices
Symbol
Remote Control
Meaning
Interface type of remote control
Setup as specified by manufacturer:
Baud Rate
Setup…
Data Bit
Stop Bit
Parity
Remote Control Product
42
Remote control type as per specified list
DTR-60XX
Setup menu (continued)
Record – Record
On the “Record” menu the basic settings for recordings and their quality are made.
Setup Menu...
Term
Record
Symbol
Record
Meaning
Recycle
Enables automatic overwriting of the oldest recordings when the
hard disk is full
Event Record Dwell
Duration of recording when an event occurs
Auto Deletion
Specify time after which automatically deleted
Use Panic Recording
Enables the panic recording function
Note: If not enabled, recording ends when the hard disk is full.
Duration of panic recording
Panic Recording Duration
No Limit
End panic recording by pressing PANIC button
xx min.
Panic recording ends after preset time or
by pressing PANIC button
ips
Number of recorded images per second in panic recording
Quality
Picture quality of the recorded images in panic recording
DTR-60XX
43
Setup menu (continued)
Record – Schedule
On the “Schedule” menu the schedule for recording is defined.
Setup Menu...
Record
Term
Symbol
Schedule On
Schedule
Meaning
Enables schedule entries
Note: A recording is made only if schedule entries are enabled.
Otherwise only panic recording is possible.
No.
Number of schedule entry
Day
Day of the week
Range
Time range at 15-minute intervals
Response:
Mode
Channels
No Record
-
Time
Always record in the defined time slot in the
quality set for “Time” mode
Event
Record only in case of event in the defined time
slot in the quality set for „Event“ mode
Time &
Event
Always record in the defined time slot in the quality set for “Time” mode, also in case of event in
the defined time slot in the quality set for “Event”
mode
Assignment of cameras to schedule
Picture data settings in Time and Event modes:
Settings
ips
Number of recorded images per second
Quality
Picture quality of recorded images
Picture data defaults in Time and Event modes:
Default...
44
ips
Number of recorded images per second
Quality
Picture quality of recorded images
DTR-60XX
Setup menu (continued)
Record – Pre-Event
On the “Pre-Event” menu the settings for recording prior to the event are made.
Setup Menu...
Term
Record
Symbol
Pre-Event
Meaning
No.
Activates the cameras
ips
Number of recorded images per second prior to the event
Quality
Picture quality of the recorded images prior to the event
Recording time prior to the event
Dwell
DTR-60XX
Note: The pre-event recording memory capacity is limited.
Consequently, the maximum recording time prior to the event,
the number of recorded images and picture quality are interdependent.
45
Setup menu (continued)
Record – Archive
On the “Archive” menu the schedules and settings for archiving are entered.
Setup Menu...
Term
Archive On
Record
Symbol
Archive
Meaning
Enables the archiving settings
Schedule
Day
Day of week from which to archive recordings
Range
Time range
Archive Data Range
Start of archiving, from:
From
Last Archived
Time of last archiving
xx/yy/200x
Defined date and time
End of archiving, up to:
To
Recycle
46
Continue
No end
xx/yy/200x
Defined date and time
Enables automatic overwriting of the oldest recordings when
the archive medium is full.
Note: If not enabled, archiving ends when the archive
medium is full.
DTR-60XX
Setup menu (continued)
Event – Alarm-In
On the “Alarm-In” menu the alarm inputs and responses to events are configured.
Setup Menu...
Term
Event
Symbol
Alarm-In
Settings
Meaning
No.
Enables the alarm inputs
Title
Name of alarm input
Contact method of alarm input:
Type
Setup Menu...
Term
NO
Normally Open
NC
Normally Closed
Event
Symbol
Alarm-In
Actions 1
Meaning
No.
Number of alarm input
Record
Assignment of cameras to record in event of alarm
These cameras must be in “Event” or “Time and Event” mode within
the time slot:
Setup Menu... > Record > Schedule
Alarm-Out
Assign and enable
● alarm outputs
● internal beep by DVR
These alarm outputs and the internal beep must be enabled within
the time slot:
Setup Menu... > Devices > Alarm-Out > Schedule
Assign and enable notifications:
Mail
Modem
Notify
LAN 1 to LAN 5
Alert Window
The selected function must be enabled:
Setup Menu... > Network > Notification
DTR-60XX
47
Setup menu (continued)
Setup Menu...
Term
Event
Symbol
Alarm-In
Actions 2
Meaning
No.
Number of alarm input
PTZ
Select PTZ cameras to record in event of alarm and select the
desired settings
Spot Monitor
Select spot monitor on which camera image is displayed in event
of alarm
48
DTR-60XX
Setup menu (continued)
Event – Motion Detection
On the “Motion Detection” menu the motion-sensitive zones are defined and responses to events configured.
Setup Menu...
Term
No.
Event
Symbol
Motion Detection
Settings
Meaning
Enables motion detection for the camera
Sensitivity of motion detection:
Sensitivity
Daytime
Nighttime
Select the motion-sensitive blocks within the time slot
Left mouse button functions:
● Click to select/deselect
● Click - hold down - drag to define a zone for selection/deletion/back
Right mouse button functions or menu in time slot to select blocks:
Zone
Min. Blocks
Select
Select complete row of blocks
Clear
Clear selection of a row
Reverse
Reverse selection of a row
Select All
Select all blocks
Clear All
Clear selection of all blocks
Reverse All
Reverse selection of all blocks
Specify in how many motion-sensitive blocks motion must be detected as
a minimum to trigger an alarm:
Daytime
Nighttime
Zone View
Mark the motion-sensitive zones (red in event of motion)
Motion Ignoring
Interval
Time interval between 2 events logged as separate events:
Daytime Setup...
Definition of “Daytime” time range
DTR-60XX
Never
Each motion detection is logged as a separate event.
49
Setup menu (continued)
Setup Menu...
Term
Event
Symbol
Motion Detection
Actions 1
Meaning
No.
Number of alarm input
Record
Assignment of cameras to record in event of alarm
These cameras must be in “Event” or “Time and Event” mode within
the time slot:
Setup Menu... > Record > Schedule
Assign and enable
● alarm outputs
● internal beep by DVR
Alarm-Out
These alarm outputs and the internal beep must be enabled within
the time slot:
Setup Menu... > Devices > Alarm-Out > Schedule
Assign and enable notifications:
Mail
Modem
Notify
LAN 1 to LAN 5
Alert Window
The selected function must be enabled:
Setup Menu... > Network > Notification
Setup Menu...
Term
Event
Symbol
Motion Detection
Actions 2
Meaning
No.
Number of alarm input
PTZ
Select PTZ cameras to record in event of alarm and select the
desired settings
Spot Monitor
Select spot monitor on which camera image is displayed in event
of alarm
50
DTR-60XX
Setup menu (continued)
Event – Video Loss
On the “Video Loss” menu checking for covert cameras and the responses to events are configured.
Setup Menu...
Term
Event
Symbol
Video Loss
Settings
Meaning
Sensitivity of check as to whether camera is covert:
Check Obscuration
Setup Menu...
Term
Never
not checked
126
very sensitive
Event
Symbol
Video Loss
Actions 1
Meaning
No.
Number of covert camera
Record
Assignment of cameras to record in event of alarm
These cameras must be in “Event” or “Time and Event” mode within
the time slot:
Setup Menu... > Record > Schedule
Alarm-Out
Assign and enable
● alarm outputs
● internal beep by DVR
These alarm outputs and the internal beep must be enabled within
the time slot:
Setup Menu... > Devices > Alarm-Out > Schedule
Assign and enable notifications:
Mail
Modem
Notify
LAN 1 to LAN 5
Alert Window
The selected function must be enabled:
Setup Menu... > Network > Notification
DTR-60XX
51
Setup menu (continued)
Setup Menu...
Term
Event
Symbol
Video Loss
Actions 2
Meaning
No.
Number of covert camera
PTZ
Select PTZ cameras to record in event of alarm and select the
desired settings
Spot Monitor
Select spot monitor on which camera image is displayed in event
of alarm
52
DTR-60XX
Setup menu (continued)
Event – Text-In
On the “Text-In” menu the text input device is defined and the responses to text input are configured.
Setup Menu...
Term
Event
Symbol
Text-In
Settings
Meaning
No.
Number of text input device
Setup
Configuration of text input >>
Title
Name of text input
Setup
Term
Port
Symbol
Meaning
Interface
Setting as specified by manufacturer of text input device (ATM,
cash-till etc.):
Setup…
Baud Rate
Data Bit
Stop Bit
Parity
Type of text input:
Text-In Product
Generic Text
Epson
Transaction Start
Character string with which text input must start for the DVR to
respond
Any Character
DVR responds to any character
Transaction End
Character string with which text input must end for the DVR to
respond
0 more line(s)
Enables recording of n more lines
Line Delimiter
Line delimiter as specified by the text input device manufacturer:
^J for LF or ^M for CR
Ignore String
Character string in the text input which the DVR is to ignore
All transmittable character strings are specified by the text input
device manufacturer.
Case Sensitive
Case sensitivity according to text input device manufacturer’s
specification
DTR-60XX
53
Setup menu (continued)
Setup Menu...
Term
Event
Symbol
Text-In
Actions 1
Meaning
No.
Number of alarm input
Record
Assignment of cameras to record in event of alarm
These cameras must be in “Event” or “Time and Event” mode within
the time slot:
Setup Menu... > Record > Schedule
Assign and enable
● alarm outputs
● internal beep by DVR
Alarm-Out
These alarm outputs and the internal beep must be enabled within
the time slot:
Setup Menu... > Devices > Alarm-Out > Schedule
Assign and enable notifications:
Mail
Modem
Notify
LAN 1 to LAN 5
Alert Window
The selected function must be enabled:
Setup Menu... > Network > Notification
Setup Menu...
Term
Event
Symbol
Text-In
Actions 2
Meaning
No.
Number of alarm input
PTZ
Select PTZ cameras to record in event of alarm and select the
desired settings
Spot Monitor
Select spot monitor on which camera image is displayed in event
of alarm
54
DTR-60XX
Setup menu (continued)
Event – System Event
On the “System Event” menu the self-diagnostics and corresponding messages are configured..
Setup Menu...
Term
Event
Symbol
System Event
Health Check
Meaning
System
System self-diagnostics interval
Check Recording
Setup... . Configuration of schedule >>
Check Alarm-In
Interval for checking Alarm Inputs
Setup…
Term
Symbol
Meaning
Schedule On
Enables schedule entries
No.
Number of schedule entry
Day
Day of the week
Range
Time range at 15-minute intervals
Interval
Checking interval
Setup Menu...
Term
Event
Symbol
System Event
Storage
Meaning
Disk Bad Notify
Percentage of bad sectors on hard disk as from which an alarm
is triggered
Disk Almost Full Notify
Percentage hard disk space available as from which “Disk
Almost Full” alarm is triggered
Setup…
Configuration of data media S.M.A.R.T. check
Opens a window in which the frequency rate and time and a
temperature limit (in Celsius or Fahrenheit) for the S.M.A.R.T.
check can be specified.
If the temperature limit is exceeded an alarm is triggered.
For details of your hard disk’s temperature limit refer to the
manufacturer’s manual.
DTR-60XX
55
Setup menu (continued)
Setup Menu...
Term
Event
Symbol
System Event
Actions
Meaning
Events (based on checks):
Event
Alarm-Out
System
System check failed
Panic Record
Panic recording in progress
Check Recording
Recording check failed
Check Alarm-In
Check of alarm inputs failed
Disk Almost Full
Preset limit value for hard disk capacity
reached
Disk Full
Hard disk full
Disk Bad
Preset limit value for number of bad
sectors reached
Disk Temperature
Preset temperature limit reached
Disk S.M.A.R.T.
S.M.A.R.T. check failed
Assign and enable
● alarm outputs
● internal beep by DVR
Note: Not possible for system event and panic recording
Assign and enable notifications:
Mail
Notify
Modem
(not in case of system event)
LAN 1 to LAN 5
(not in case of system event)
Alert Window
(not in case of system event)
The selected function must be enabled:
Setup Menu... > Network > Notification
56
DTR-60XX
Setup menu (continued)
Event – Event Status
The “Event Status” menu indicates the status of all possible events:
● Grey text: Event detection not enabled
● White text: Event detection enabled
● Flashing border: Message – acute event for 5 sec
● Yellow field: Pending event
Setup Menu...
Event
Event Status
Event Status
Term
Event
Alarm-In
At alarm input 1 to 16
Check Alarm-In
Error detected at one of alarm inputs 1 to 16
Motion
Motion detected on camera 1 to 16
Video Loss
Video loss on camera 1 to 16
Text-In
Text input on text input device 1 to 16
Panic Record
Panic recording
Check Recording
On checking the recording
Disk Almost Full
On checking the data medium (only if DVR is not operating in Overwrite
mode)
Disk Full
On checking the data medium (only if DVR is not operating in Overwrite
mode)
Setup Menu...
Event
Event Status
Term
Meaning
Type
Memory type
Disk Bad
Data carrier status
Temperature
Data carrier status
S.M.A.R.T.
Result of S.M.A.R.T. check
DTR-60XX
Storage
57
WebGuard – WebWatch controls
The following diagram and table set out the functions on the Web Watch:
1
2
4
5
6
7
8
9
10
No.
Designation
Function
1
WebGuard Logging out
2
Open Search (WebSearch)
3
DVR
4
5
6
● Date/Time
● IP Address
● User Name
Image display modes
Display
To
Change camera name and image aspect ratio
Select cameras
Image optimisation
7
PTZ camera functions
Activate Alarm Outputs
8
Save current recording data
9
Set up image drawing mode
10
58
Display
Event log
DTR-60XX
WebGuard – WebSearch controls
The following diagram and table set out the functions on the Web Search:
1
2
4
5
6
7
8
9
10
11
12
No.
Designation
1
WebGuard Logging out
2
3
Open Display (WebWatch)
DVR
4
5
Function
Display date/time, IP address and user name
Zoom On/Off and image optimisation
Display
Change camera name and image aspect ratio
6
Playback functions
7
Image display modes
8
Display
Time bar calendar search and event log
Search for date/time
9
Calendar search
Event Search
10
Reload recording data
11
Set up image drawing mode
Save any video clip as an EXE file
12
Save current image as BMP or JPEG file
Print
DTR-60XX
59
Using WebGuard
WebGuard permits the following, using an Internet connection
● View current video images
● Search and view recorded records
Requirements:
● The Internet connection is set up and the WebGuard service is activated.
● A PC with Internet access to the DVR must be available.
● Internet Explorer must be installed on the PC.
Using WebGuard
Step
Action
1
Ask your System Administrator about the current access data.
2
Start Internet Explorer.
Enter the access data in the address line, e.g.: 192.168.1.129:12088
3
Enter your User Name (admin), Password (blank) and if necessary the port addresses.
4
60
Select Login.
Result: WebGuard window is opened.
DTR-60XX
Specifications DTR-6008
Model
DTR-6008/250CD
DTR-6008/500CD
DTR-6008/750CD
EDP No.
71942
71961
71962
Video standard
PAL/NTSC (auto detection)
Remark
-
Event logs
Unlimited number of entries for alarm/event/text messages, loss of signal
Security against unauthorised
use
Key locking, 64 user groups with programmable access (up to 256 users)
Transmission rate
100 images per sec (PAL)
Alarm triggering
E-mail, remote SW (RAS)
Alarm activation
Automatic multi-screen display of alarm images programmable
Remote Control
Wireless IR remote control (included)
Text display interface
ATM/POS, 10 channels max.
Monitor display
Real-time playback: 25 field images per sec (PAL), 30 field images per sec
(NTSC) per camera
Covert camera mode
Programmable
Time synchronisation
Network time log, network time server
System change log
Up to 5000 entries for login/logout, configuration changes, remote access,
change of signal connection, disk read/write errors
Zoom function
2x~4x
Playback
Frame image, 4-/8-channel split
Post-alarm recording
Up to 15 minutes
VGA
-
Control interface
RS-485 port for PTZ control (verified logs: eneo-Fastrax, Pelco P/D) or
keyboard connection for remote control
Activity detection
Programmable 16 x 16 (256) grid, 5 sensitivity settings
Simplex/Duplex/Triplex/Pentaplex mode
Triplex
Video inputs
8x 1 Vp-p, (F)BAS, 75 Ohm, BNC, loop-through
Monitor outputs
4x Spot-Outputs 1Vss, (F)BAS, 75 Ohm, BNC, 1x VGA
Video output
1x 1 Vp-p, (F)BAS, 75 Ohm, BNC; 1x S-VHS, S= 1 Vp-p, C= 0.3 Vp-p, 75
Ohm
Audio input
4x amplifier input, cinch
Audio output
1x amplifier output, cinch
Resolution
720 x 576 pixels (display)
Compression method
MPEG-4, higher compression rates with same picture quality enable maximum recording times
Recording speed
200 field image per sec at CIF resolution (336 x 272 pixels/PAL),
100 field image per sec at 2CIF resolution (672 x 272 pixels/PAL)
50 field image per sec at D1 resolution (720 x 576 pixels/PAL)
DTR-60XX
61
Specifications DTR-6008 (continued)
Model
DTR-6008/250CD
Picture size
Basic: 2/2.4 kB; Standard: 4/4.8 kB; High: 8/9.6 kB; Very high: 12/14.4 kB
(NTSC/PAL). 2 times larger in High Resolution mode
DTR-6008/500CD
Hard disk capacity
250 GB ATA hard
disk, expandable to
as many as 3 internal
hard disks
Playback speed
200 field image per sec at CIF resolution (336 x 272 pixels/PAL) and Duplex
Export of picture data
via USB 2.0, SCSI port, CD writer.
Network data export: Clip Player, AVI, JPG, BMP
Alarm inputs
8x TTL, programmable as NC/NO (terminal strip)
Alarm outputs
8x TTL, open collector (terminal strip)
Alarm reset
2~4 TTL (terminal strip)
Alarm messages
System error, hard disk error
500 GB ATA hard disk,
expandable to as many
as 3 internal hard disks
DTR-6008/750CD
750 GB ATA hard
disks
Pre-alarm recording
Up to 30 minutes
Recording medium
ATA-2 (EIDE) hard disks, built-in CD-RW writer
Archiving
With EIDE, SCSI and USB hard disks. Real-time mirroring
Menu languages
German, English, Italian, French, Spanish, Polish, Russian, Czech, Hungarian
Ethernet port
10Base-T, 100Base-TX, RJ-45
Remote software
For remote administration and image search function (RAS plus included)
Ports
3x USB, 1x RS-485, 1x RS-232 (remote control/configuration or modem), 1x
SCSI for memory expansion
Power Supply
100 VAC~230VAC, 50/60Hz
Power consumption
approx. 150 W
Temperature range
5°C to 40°C
Housing
Metal with plastic front panel
Colour
Pantone 427C
Dimensions (H x W x D)
88 x 430 x 405 mm
Weight
approx. 7.4 kg
62
DTR-60XX
Specifications DTR-6016
Model
DTR-6016/250CD
DTR-6016/500CD
DTR-6016/750CD
EDP No.
71929
71959
71963
Video standard
PAL/NTSC (auto detection)
Remark
-
Event logs
Unlimited number of entries for alarm/event/text messages, loss of signal
Security against unauthorised
use
Key locking, 64 user groups with programmable access (up to 256 users)
Transmission rate
100 images per sec (PAL)
Alarm triggering
E-mail, remote SW (RAS)
Alarm activation
Automatic multi-screen display of alarm images programmable
Remote Control
Wireless IR remote control (included)
Text display interface
ATM/POS, 10 channels max.
Monitor display
Real-time playback: 25 field images per sec (PAL), 30 field images per sec
(NTSC) per camera
Covert camera mode
Programmable
Time synchronisation
Network time log, network time server
System change log
Up to 5000 entries for login/logout, configuration changes, remote access,
change of signal connection, disk read/write errors
Zoom function
2x~4x
Playback
Frame image, 4-/9-/16-channel split
Post-alarm recording
Up to 15 minutes
VGA
-
Control interface
RS-485 port for PTZ control (verified logs: eneo-Fastrax, Pelco P/D) or
keyboard connection for remote control
Activity detection
Programmable 16 x 16 (256) grid, 5 sensitivity settings
Simplex/Duplex/Triplex/Pentaplex mode
Triplex
Video inputs
16x 1 Vp-p, (F)BAS, 75 Ohm, BNC, loop-through
Monitor outputs
4x Spot-Outputs 1Vss, (F)BAS, 75 Ohm, BNC, 1x VGA
Video output
1x 1 Vp-p, (F)BAS, 75 Ohm, BNC; 1x S-VHS, S= 1 Vp-p, C= 0.3 Vp-p, 75
Ohm
Audio input
4x amplifier input, cinch
Audio output
1x amplifier output, cinch
Resolution
720 x 576 pixels (display)
Compression method
MPEG-4, higher compression rates with same picture quality enable maximum recording times
Recording speed
400 field image per sec at CIF resolution (336 x 272 pixels/PAL),
200 field image per sec at 2CIF resolution (672 x 272 pixels/PAL)
100 field image per sec at D1 resolution (720 x 576 pixels/PAL)
DTR-60XX
63
Specifications DTR-6016, continued
Model
DTR-6016/250CD
Picture size
Basic: 2/2.4 kB; Standard: 4/4.8 kB; High: 8/9.6 kB; Very high: 12/14.4 kB
(NTSC/PAL). 2 times larger in High Resolution mode
DTR-6016/500CD
Hard disk capacity
250 GB ATA hard
disk, expandable to
as many as 3 internal
hard disks
Playback speed
400 field image per sec at CIF resolution (336 x 272 pixels/PAL) and Duplex
Export of picture data
via USB 2.0, SCSI port, CD writer.
Network data export: Clip Player, AVI, JPG, BMP
Alarm inputs
16x TTL, programmable as NC/NO (terminal strip)
Alarm outputs
16x TTL, open collector (terminal strip)
Alarm reset
2~4 TTL (terminal strip)
Alarm messages
System error, hard disk error
500 GB ATA hard disk,
expandable to as many
as 3 internal hard disks
DTR-6016/750CD
750 GB ATA hard
disks
Pre-alarm recording
Up to 30 minutes
Recording medium
ATA-2 (EIDE) hard disks, built-in CD-RW writer
Archiving
With EIDE, SCSI and USB hard disks. Real-time mirroring
Menu languages
German, English, Italian, French, Spanish, Polish, Russian, Czech, Hungarian
Ethernet port
10Base-T, 100Base-TX, RJ-45
Remote software
For remote administration and image search function (RAS plus included)
Ports
3x USB, 1x RS-485, 1x RS-232 (remote control/configuration or modem), 1x
SCSI for memory expansion
Power Supply
100 VAC~230VAC, 50/60Hz
Power consumption
approx. 150 W
Temperature range
5°C to 40°C
Housing
Metal with plastic front panel
Colour
Pantone 427C
Dimensions (H x W x D)
88 x 430 x 405 mm
Weight
approx. 10.2 kg
64
DTR-60XX
Accessories
EDP No.
Short description
71857
250GB hard disk for DLR/DXR/DTR and DCR
71919
500GB hard disk for DLR/DXR/DTR and DCR
71970
CD/DVD Writer DVD+/-RW 48x/18x, CD/DVD
74088
System keyboard with 3-axis joystick
74092
System keyboard with joystick, 5” monitor
71902
USB mouse for DVR series DXR, DLR3
DTR-60XX
65
Supported PTZ cameras
Manufacturer
Designation
Manufacturer
Designation
Costar
CDC 2500
Ademco Video
Orbiter Microsphere
Dyna Color
CDC2400
SysMania
ORX_1000
Chilsung
CRD-J6416
Linlin
PIH-717
Fine
CRR-1660s
ELMO
PTC-200C/CVAS
Pelco
D-log
ELMO
PTC-250C
Dennard
Dennard2060
Pacom
Pacom 2036
Tokina
DMP-1223
Dongyang
Power Controller
Dongyang Unitech
DRX-500
Sungjin
Receiver/MPU
Dongyang
DY-255RXC
Costar
SIC722V
Sensormatic
Delta Dome II/Ultra IV
Samsung Techwin
SPD 1600
Eneo
Fastrax
Samsung
Samsung Dome
Philips
G3 Basic AutoDome
Pelco
Spectra Dome
LG Honeywell)
GRU604A
Samsung Techwin
SRX-100B
JVC
TK-S576
Hitron
Speed Dome
Sensormatic
Ultra VI
Canon
VC-C4
Canon
VC-C50i
Inter-M
VRX-2201
Vicon
Vicon
Hitron
22x AF Zoom
360Vision
VisionDome
Panasonic
WJ-SX550A
Panasonic
WV-CS850/854
CBC
ZC-SD622J
Samsung
Zoom Camera
Honeywell
HDC-655
LG Honeywell
HSD-25X
Honeywell
HSDN-251
Idis
IRX-100
Ultrak
KD6
Ultrak
KD6 Z-series
Kalatel
KTD-312
LG
LPT-A100L
Novus-C
Samsung
66
MRX-1000
DTR-60XX
Index
A
Accessories 65
Alarm
Configuring inputs 47
Configuring outputs 40
Connecting inputs 8
Connecting outputs 8
Motion Detection 50
Resetting 9
Setting schedule for outputs 40
Setting signal duration 40
Ambient conditions 3, 62
Archiving
Configuring 46
Memory requirement 21, 46
Setting schedule 46
Assigning cameras
Alarm-In 47
Motion Detection 49, 50
Text-In 54
Video Loss 51
Assigning PTZ cameras
Alarm-In 48
Motion Detection 49, 50
Text-In 54
Video Loss 52
B
Basic functions 7
C
Calendar search 23
Cameo 42
Cleaning 3
Clip-Copy 27
Configuring a pre-event 45
Configuring audio outputs 39
Configuring event responses 47
Configuring Motion Detection 49
Configuring panic recording 43
Configuring PTZ cameras 38
Configuring remote control 42
Configuring text input as event 53
Configuring the cameras 38
Configuring video loss as event 51
Connecting cameras 8
Connections 8
Control options 7
DTR-60XX
Control protocols 66
Controls
Front panel 9
Remote Control 11
WebSearch 59
WebWatch 58
Copying recordings 27
Covert mode 19, 38
D
Date setting 30
Defining group access rights 33
Defining motion-sensitive zones 49
Display
Configuring 41
Hiding 19, 38
Displaying event status 57
Display menu
Access 14
Disposal 70
DVRNS
Network configuration 36
Dwell 40
E
E-mail Notification 37
EMC class 3
Enabling notification
Alarm-In 47
Motion Detection 50
System Event 56
Text-In 54
Video Loss 51
Event
Configuring a pre-event 45
Configuring responses 47
Defining motion-sensitive zones 49
Displaying status 57
Setting recording time 43
System events 55
Text input 53
Video Loss 51
Event log 24
F
Front panel 9
Controls 9, 10
67
Index (continued)
G
Getting started
Video recorder 3, 16
H
PTZ cameras
Connecting 8
Supported cameras 66
R
LAN
Network configuration 35
Recording
Copying 27
delete 18
Memory requirement 21
Search 22
Setting schedule 44
Recreate factory settings 19
Recycling the device 70
Remote Control
Controls 11
Setting system ID 16, 29
Reset 8, 19
M
S
Hard disks
Mirroring 20, 31
Health Check 55
I
IP Address 35, 36
L
Memory requirement
Archiving 21, 46
Recording 21
Memory type 31
Menu descriptions
Search menu 22
Setup menu 28
Menu structure 12
Mirroring of hard disks 20, 31
Modem
Network configuration 35
Monitor
Configuring display 41
Configuring display sequence 42
Connecting 8
Motion Search 26
N
Network configuration 34
Network settings
DVRNS 36
LAN 35
Modem 35
P
Package contents 7
PANIC 9, 43
PTZ-menu
Access 14
68
Safety instructions 3
Schedule
Setting for alarm 40
Setting for archiving 46
Setting for recording 44
Search
Calendar search 23
Event log 24
Motion Search 26
Text-In 25
Search-menu
Access 15
Setting a password 33
Setting automatic overwrite 43
Setting menu language 29
Setting recording quality 43
Setting system ID for remote control 29
Setting the duration of records in an event occurrence 43
Setting up a concealed camera 19, 38
Setting up Notification 37
Setting up user groups 33
Setting up users 33
Setup menu
Access 15
Menu descriptions 28
Shutdown 17
Software updates 19
Software version 29
Specifications 61
DTR-60XX
Index (continued)
Specifying public holidays
30
Spot Monitor
Assigning a camera 42
Connecting 8
Storage media
Displaying status 31
Displaying usage 31
Setting automatic overwrite 43
Switching off 17
Switching on 17
System
Export setup 29
Import setup 29
Logging out as USER 34
Shutdown 34
System events
Configuring 55
Health Check 55
T
Text-in search 25
Time
Setting 30
Synchronising 30
W
WebGuard
Controls 58, 59
Use 60
WebSearch
Controls 59
Use 60
WebWatch
Controls 58
Use 60
DTR-60XX
69
Notes on disposal
Correct disposal of this DVR
WEEE (Waste Electrical & Electronic Equipment)
Applicable in the member states of the European Union and other European countries with a separate collection system
The marking on the DVR and on the documentation stipulates that it must not be
thrown away in normal domestic waste at the end of its useful life.
General rules
► Avoid uncontrolled waste disposal: Please dispose of this DVR separately from other waste, so as to avoid
posing a hazard to the environment and to human health.
► Recycle the DVR in order to aid the sustainable reuse of material resources.
Private users
► Contact the retailer from whom you purchased the DVR or your competent local authority to find out how
you can recycle the DVR in an environmentally friendly way.
Commercial users
► This DVR must not be thrown away with trade waste. To clarify the conditions of disposal, check your
purchase contract or contact your supplier.
70
DTR-60XX
eneo® is a registered trademark of Videor Technical E. Hartig GmbH
Exclusive distribution through specialised trade channels only.
VIDEOR TECHNICAL E. Hartig GmbH
Carl-Zeiss-Str. 8 · 63322 Rödermark, Germany
Tel. +49 (0) 6074 / 888-0 · Fax +49 (0) 6074 / 888-100
www.videortechnical.com
Operating Instructions version 03/2008 (V1.0)
Subject to technical change without notice.
© Copyright by VIDEOR TECHNICAL 2008