OWNER’S MANUAL

WINDOW EVAPORATIVE AIR COOLER

MODEL: N30W

READ AND SAVE THIS INSTRUCTION MANUAL

Date Purchased: _______________________________

Purchased From: _______________________________

P/N 70852

REV. 4/09

Evaporative Cooling

Evaporative cooling uses the principle of evaporation to lower the air temperature. Hot, dry air is passed through wetted fi lters and is converted to refreshingly cooled air. Essick Coolers make the best use of the evaporative process by controlling the fl ow of water, spreading the water evenly over the fi lters, and keeping a steady stream of cooled air entering your home. It is exhausted out open windows or doors, carrying heat, smoke and odors along with it. Essick evaporative coolers are up to 80% less costly to operate than refrigerated air conditioners.

Cautions: To prevent harm to yourself and others, and to avoid damage to your cooler, PLEASE follow these guidelines.

When Installing When Operating When Servicing

Make sure that unit is installed on a sound structure that will support the full operating weight of the cooler. See page 4.

Make sure that circuit cooler is plugged into is equipped with a (slow blow) breaker large enough to support the full amperage of the cooler

Always Unplug the cooler before attempting service of any kind.

Before attempting to hang the cooler in To reduce the risk of fi re or electrical the window, remove the louver to reduce weight.

shock, DO NOT use this fan with any

Solid-state speed control device.

Be sure to disconnect nit from power source before servicing. If not, it can be turned on from inside the house and start unexpectedly.

Do Not connect power to cooler before installation is complete.

This cooler is equipped with an automatic thermally protected motor. If it shuts off on its own for any reason, it can restart without warning.

If the motor shuts off because of thermal overload, check into the problem immediately. If allowed to continue, permanent damage will occur.

MOUNTING

To install this cooler, the following tools are required:

• Screwdrivers

• 3/16” drill bit

• Level

1. Cut the Side Sealer Channels so that two of them will span the window when butted together. Place two of the channels on the bottom duct fl ange as shown.

2. Place the cooler in the center of the window with the bottom duct fl ange resting against the sill.

3. Pull out the Spacer-Rods so as to allow the Rubber Feet to rest against the side of the house. Tighten the Adjustment Screws.

4. Lower the window to rest on top of the duct behind the top duct fl ange.

5. Fasten a stop above the inside window sash to prevent the window from being raised. Raising the window may cause the cooler to fall.

6. Adjust the Spacer-Rods to level the cooler. This will ensure proper water fl ow to the pads.

7. Install the Chain Supports (Not Included).

a. Drill pilot holes in the window frame, 3 feet above the top of the duct and the width of the cooler apart. Install the Screw-Hooks in these pilot holes to the full depth of the thread.

b. Hook one end of each Chain over each Screw-Hook.

c. Place S-Hooks in the holes at the top rear of the cooler.

d. Place the opposite end of the S-Hooks in the free end of each Chain.

Make sure the chains are taut, but not so tight they pull the bottom of the cooler away from the wall.

CHAIN

S-HOOK

Side Sealer

Channel

SCREW

HOOK

2

8. Install the Side Sealer Panels. These panels are the correct height, but need to be trimmed to fi t the width of our window. Trim the panels so that they reach from the window frame to the side of the duct. Slide the panels in the channels you placed on the bottom duct fl ange. Install the remaining Side-Sealer Channels over the top duct fl ange and the Side-Sealer Panels.

INSTALL OVERFLOW AND DRAIN

1. Slide the Rubber Washer over the Drain Bushing and push through the hole in the bottom of the cooler from the top side.

2. Secure the Drain Bushing from beneath the pan with the Lock Nut. Make sure the

Rubber Washer does not twist while tightening, which could cause it to leak. NO

NOT OVERTIGHTEN.

3. Thread the Overfl ow Tube into the Drain Bushing and HAND TIGHTEN.

4. If leakage occurs after Reservoir is full retighten the Overfl ow Pipe until leaking stops. A small amount of silicone caulk may be used if necessary.

FLOAT VALVE INSTALLATION

1. Place the threaded portion of the Float Valve through the hole provided in the

Float Bracket (inside unit) as shown.

2. Slip the Fiber Washer over the threaded portion of the fl oat and secure with the

Ring Nut. Be sure the Float does not turn while you are tightening the nut.

WATER LINE CONNECTION

1. Find the closest outside water faucet, and install a Water Connection Kit (not included with cooler) as shown. If an exterior faucet is not available, locate the closest cold water pipe and install a saddle valve assembly.

2. Route tubing into cooler. Place Compression Nut and Ferrule over end of tubing. Insert the tubing into fl oat valve and tighten Compression Nut to secure.

NOTE: Over tightening a compression fi tting will cause that fi tting to leak.

It is best to secure the connections, turn on the water, and then snug the fi tting until leaking stops.

ADJUSTING WATER LEVEL AND FLOAT VALVE

1. To adjust water level, bend the fl oat valve rod.

2. Check all water connections for leaks.

3. Make sure the Float Valve cuts off completely when the desired water level has been reached (1/2” to 3/4” below top of Overfl ow Tube). If the fl oat does not stop the water completely, the water level will rise and run out the Overfl ow Tube.

4. Double check the Overfl ow Tube for leaks.

START UP

1. Plug in the electrical cord to a standard grounded receptacle. Be sure the circuit breaker protecting the receptacle is of suffi cient size.

2. Open windows in rooms where you want cooling to be directed.

3. Turn the cooler to the High Fan position. Observe the amount of air being delivered. Note: On cool nights (or days) or when the humidity level is high, the fan positions may be used for ventilation purposes.

4. Turn the cooler to the Low Fan position. This should signifi cantly reduce the amount of air being delivered.

5. Turn the cooler to the Pump Only position. The pump should run and not the fan. Check to see that water is fl owing from all three Water Trays.

6. Turn the cooler to the High Cool position. Check to see that all three Pads are wetting evenly with no dry patches. The Pads may take up to 20 minutes to wet fully. If the Pads have dry patches, you can adjust the level of each Water Tray by screws on each end.

7. Adjust window openings to achieve desired cooling level.

Overflow

Tube

Bushing

Rubber

Gasket

Lock

Nut

Reservoir

Faucet

Side Sealer

Side Sealer Channel

Compression

Nut

Ferrule

Ring Nut

Fiber Washer

Float

Ferrule

Compression

Nut

Sillcock

Water Supply

Valve

3

MAINTENANCE

1. Once a month during cooling season, inspect your cooler for leaks, blocked water lines and excessive residue build-up on the pads.

2. At the end of the season, drain the reservoir. Remove the drainpipe and let water and dirt pass through the drain fi tting.

3. Lime build-up can occur in the water reservoir and on louvers. Clean this off at least once per season. If any rust or bare metal spots occur on the cabinet or louver, the metal should be sanded, primed and painted with a good quality paint.

4. If freezing weather occurs in your area, it is best to shut off the water supply at the source and drain the supply line to the cooler.

5. A cooler cover is recommended to prevent rain and weather from damaging your cooler.

6. To prevent the Shaft from rusting, coat with a wax based lubricant. Allow lubricant to dry completely and all fumes to disperse before turning on the cooler.

DO NOT GET WATER ON MOTOR OR PUMP MOTOR

NOTE: Depending on the mineral content of the water or the amount of air borne dust in your are, you may need to replace fi lter pads during the season.

It is best to replace fi lter pads again at the end of the season. Old fi lter pads soak up lime and salts, which can rust the louvers and the cabinet during the winter months.

TO REPLACE PADS

1. Remove louver (U) from cooler.

2. Unhook pad holders (V) at the sides of the louver and above and below side pads inside cooler.

3. Remove old pads (W) and discard.

4. Tuck in rear pad to make sure hot air can not by-pass fi lter.

5. Place pad holders over new pad and hook into place.

6. For the side pads, center pad over louver openings in cabinet, hook pad holder below pad, tilt into place and hook at top.

WIRING DIAGRAM

TROUBLESHOOTING

Problem

Motor cycles on and off

Cause

• Extension cord (if one used) too long

• Circuit breaker not large enough

Fails to start • No electrical power

• Circuit breaker tripped or fuse blown

Water draining from overfl ow • Float improperly adjusted

Blower vibrates excessively or rattles

• Blower wheel out of balance or out of alignment

• Debris in blower housing

Not cooling • Blocked water lines

• Windows opened too little or too much.

• Uneven pad wetting

• Pump clogged or failed

• Pads plugged with dirt and water deposits

4

Remedy

• Choose a shorter or heavier gauge cord

• Consult a licensed electrician

• Check all electrical connections and cords

• Reset circuit breaker or replace fuse

• Adjust fl oat

• Replace the blower wheel

• Clear debris

• Check incoming water line, fl oat and water distributor for blockages and clear.

• Adjust window openings

• Level water trays, check for blocked water slots in water trays

• Clean pump or replace

• Replace pads

REPLACEMENT PARTS

N30W

Item Description

1 Cabinet

2 Blower

3 Duct

4 Side Sealer

5 Louver

6 Water Tray - Back

7 Water Tray - Side

8 Filter - Back

9 Filter - Side

10 Pad Retainer - Back

11 Pad Retainer - Side

12 Motor

13 Blower Wheel

14 Motor Mount Bushing

15 Motor Mount

16 Stand-off Bracket

17 Stand-Off Rod

18 Rubber Foot

1

4

2

1

2

2

2

1

2

2

2

2

Qty

1

1

1

2

1

1

Part No.

322160-001

70866

322120-001

110603

224007-007

226003-002

226004-001

110098

110084

3PW-5

70415

110441-2

110764

110731

218109-001

70417

110811

110706

Item Description

19 Water Distributor

20 Pump Assembly

21 Pump Bracket

22 Water Hose

23 Switch

24 Knob

25 Side Sealer Channel

26 Float Valve

27 Water Overfl ow Kit

28 Sub-Vent Assembly

29 Louver Assembly

30 Inlet Ring

31 Float Bracket

32 Switch Bracket

33 Grill Frame

34 Cord

35 Top

36 Switch Box

1

1

1

1

1

1

4

1

1

1

1

1

Qty

1

1

1

1

1

1

Part No.

3D-30

70569

504281

70276

110425

110839-006

110599

FL-C

3OA-1

310839-103

324007-107

224120-004

70373

70798

110839

70414

222160-007

524342

5

1.

2.

3.

4.

5.

Instructions to Convert Unit to Vertical Duct Confi guration

Remove the 13 screws holding the Duct in place.

Turn the Duct 90 degrees counter-clockwise.

Align the Duct with the 3 holes provided above the blower panel.

Insert 3 screws at the top and bottom of the duct.

Place the Duct Mount Strip over the side Duct Flange and insert 3 screws into the holes provided.

Proceed with the installation as normal. The side Sealer Channels will go on the same fl anges as for a horizontal duct.

You may use the Side Sealers provided to close off the window above your cooler’s duct.

LIMITED WARRANTY

This warranty is extended to the original purchaser only. It does not cover damages incurred during shipping or through accident, neglect, or abuse by the owner. Essick Air Products does not authorize any person or representative to assume any other or different liability in connection with this cooler.

TERMS AND CONDITIONS OF WARRANTY

The BOTTOM PAN is guaranteed against leakage due to rusting out for Five Years. All other original parts provided by

Essick Air Products are warranted against defects in material or factory workmanship for One Year.

EXCLUSIONS FROM THE WARRANTY

Essick Air Products is not responsible for incidental or consequential damage resulting from any malfunction.

Essick Air Products is not responsible for any damage occurring from the use of water softeners, chemicals, de-scale material, or if a higher horsepower motor than what Essick Air Products recommends is used in the unit.

Essick Air Products is not responsible for the cost of service calls to diagnose cause of trouble, or labor charge to repair and/or replace parts.

HOW TO OBTAIN SERVICE UNDER THIS WARRANTY

Contact the Dealer where you purchased the evaporative cooler. If for any reason you are not satisfi ed with the response from the Dealer, contact the Customer Service Department: Essick Air Products Inc., 5800 Murray Street, Little