Frigidaire FRP12PTT2A Product Specifications Sheet
Add to my manuals6 Pages
Frigidaire FRP12PTT2A is a packaged terminal air conditioner (PTAC) that combines cooling, heating, and dehumidification functions in one compact unit. It features simple controls for customized settings, ensuring a comfortable room temperature. The PTAC's self-check function provides nine diagnostic points for easy troubleshooting and correction of any issues. With its eco-friendly R-410A refrigerant and effortless operation, the Frigidaire FRP12PTT2A is an energy-efficient and reliable climate control solution for various applications.
advertisement
Packaged Terminal Air Conditioner (PTAC)
FRP12PTT2R
Air Conditioner /
Heat Pump /
Backup Electric Heater
Product Dimensions
Height
Width
Depth
16"
42"
13-13/16"
More Easy-To-Use Features
Comfort Control Design
Simple controls allow guests to customize their settings, while quiet, uniform air movement keeps rooms comfortable.
Smart Self-Check
Provides nine diagnostic points for selfcheck and correction of fault conditions.
Eco-Friendly
Frigidaire® uses R-410A refrigerant that’s not harmful to the earth’s ozone layer and meets U.S. Environmental Protection
Agency requirements.
Effortless™ Operation
Simple, intuitive room controls are easy for guests to operate — ensuring a relaxing, more comfortable stay. Features like Effortless™ Restart and Ready-Select® controls reduce maintenance calls.
Performance
Cool
Backup Electric Heater
Heat Pump
BTUs
12,000 / 11,800
10,200 / 8,300
10,700 / 10,500
Signature Features
SilentDesign™
Sound reduction package.
Energy-Saver Option
This function effortlessly maximizes energy efficiency while keeping guests comfortable.
Effortless™ Maintenance
With Frigidaire’s reputation for durability, easy maintenance, availability of reliable parts and service you can count on, you can be sure that you’re getting the highest-quality performance.
Effortless™ Temperature
Control
Frigidaire® air conditioners maintain the preset room temperature so the room remains comfortable at all times and helps control energy levels. frigidaire.com
Packaged Terminal Air Conditioner (PTAC)
FRP12PTT2R Air Conditioner / Heat Pump / Backup Electric Heater
Performance
BTU (Cool)
BTU (Backup Electric Heater)
BTU (Heat Pump)
Dehumidification (Pints / Hour)
Cool Area (Sq. Ft.)
Energy Efficiency Ratio
Electrical
Volts
Amps (Cool)
Amps (Backup Electric Heater)
Amps (Heat Pump)
Watts (Cool)
Watts (Backup Electric Heater)
Watts (Heat Pump)
Cable Included
Length of Power Cord
Circuit Breaker
Plug Type (NEMA)
Features
12,000 / 11,800
10,200 / 8,300
10,700 / 10,500
2.7
1,010 / 990
Yes
5.5'
20A
LCDI (6-20P)
A
F R
640
10.7 / 10.5
Frigidaire
Room
RAC P-TAC Models
Frigidaire Baseline
1,120 / 1,120
3,000 / 2,452
Electronic Controls
Front Desk Control Ready
Fan Speeds (Cool / Fan / Heat)
Ready-Select® Controls
Yes
3 / 3 / 3
Noise Level Indoors (High / Med / Low)
Quiet Start-Up
53 /52 / 51
Yes
Low Voltage Start-Up
Random Restart Protection
Effortless™ Auto Freeze Protection
Energy Save
24-Hour On / Off Timer
Air CFM (High / Med / Low)
Air Direction Control
Air Intake
Filter Type
Filter Access
Fin Coating
Slide-Out Chassis
Commercial Grade Warranty 1
Yes
Yes
Yes
Yes
Yes
315 / 295 / 275
Auxiliary 2-Way
Fresh or Recycled
Nylon Mesh
Slide-Out
Normal
Yes
Yes
Certifications
Safety Certification
Performance
Specifications
UL, CUL & CSA
AHRI & CEC
Refrigerant
Charge
Shipping Weight (Approx.)
R410a
26.8 oz.
135 Lbs.
1 Warranty 5 year sealed system / 1 year full parts and labor.
C
P
PTAC Nomenclature
90 E T T 2 R
PTAC
BTU
77= 7,700
90= 9,000
12= 12,000
15= 15,000
Voltage
2= 230/208V
3= 265V
Design Year
T= 2010
U= 2011
Platform
Heat Type
E= Electric
P= Heat Pump
R= Normal no accessories
A= Seacoast no accessories
S= Normal w/ accessories
B= Seacoast w/ accessories
B
Plug Type (NEMA)
6-20P
NOTE: For planning purposes only. Always consult local and national electric codes. Refer to Product
Installation Guide for detailed installation instructions on the web at frigidaire.com.
Product Dimensions
A - Height
B - Width
C - Depth
Max. Wall Thickness
16"
42"
13-13/16"
13-13/16" 2
2 Unless the PTAC unit is installed with a wall sleeve.
Wall Cutout Dimensions
Height
Width
16-5/16"
42-3/16"
Accessories information available on the web at frigidaire.com
USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-866-942-1567 • frigidaire.com
CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-866-942-1567 • frigidaire.ca
FRP12PTT2R 08/11 © 2011 Electrolux Home Products, Inc.
Specifications subject to change.
Printed in the U.S.A.
PTAC - Heat Pump and Electric Heat models_Prod Specs
Packaged Terminal Air Conditioner (PTAC)
FRP12PTT2R Air Conditioner / Heat Pump / Backup Electric Heat
Rearward Slope
Wall Sleeve
Adapter 1/4 " Slope
Front Panel
Accessory
Outdoor Grille
Accessory
Wall Sleeve
Outside Wall Inside Wall
Chassis
Product Dimensions
Height
Width
Depth
Max. Wall Thickness
16"
42"
13-13/16"
13-13/16"
Wall Cutout Dimensions
Height
Width
16-5/16"
42-3/16"
Manufacturer Wall Sleeve Part Number
Amana
PTAC Specifications Trane
• Product Shipping Weight (approx.) – 135 Lbs.
• An electrical supply with grounded three-prong receptacle is required.
The power supply circuit must be installed in accordance with current edition of National Electrical Code (ANSI/NFPA 70) and local codes & ordinances.
• Voltage Rating – 230V / 208V / 60 Hz / 20 Amps
• Amps @ 230/208V Volts = (Cool) 5.1 / 5.3 Amps / (Backup Electric
•
Heater) 13.2 / 12.2 Amps / (Heat Pump) 4.5 / 4.7 Amps
Always consult local and national electric codes.
• Recommended Circuit Breaker – 20 Amps
• Unit equipped with 230/208V 3-wire power supply cord, NEMA plug
• type 6-20P, approximately 66" long.
In order for condensate water to drain properly inside the unit, the sleeve must be installed properly: Level from right to left with a slight
1/4" rearward pitch from the indoor side to the outdoor side as shown in the illustration above. Refer to the Installation Instructions on the web.
• The drain kit listed on the Frigidaire® PTAC Accessories page can be used for an internal or external drain. This applies to new and replacement installation.
General Electric
Metal Sleeve RAB71
Plastic Sleeve RAB77
Metal Sleeve WS900B
Plug Type (NEMA)
6-20P
Replacement Installation
• When replacing existing PTAC with new unit, refer to Product
Installation Guide on web to identify existing wall-sleeve manufacturer and size compatibility. If proper installation and slope are suspect, then correct installation of Frigidaire® PTAC Sleeve options recommended.
• For any sleeve retrofit application, be sure that the foam seals
(factory-installed on the tube sheets) provide a good seal between the grille and the outdoor coil tube sheets. These foam seals provide a barrier that stops air from the inside mixing with air on the outside
(known as air recirculation).
• Using Frigidaire® wall sleeve with Non-Frigidaire grille requires installation of an Accessory Baffle Kit, which ensures a good seal between the unit and exterior grille to prevent air recirculation. Air recirculation is a large contributor to performance loss and premature damage to major components.
Note: For planning purposes only. Refer to Product Installation Guide on the web at frigidaire.com for detailed instructions.
*See Frigidaire® PTAC accessories pages attached for optional accessories.
New Installation
• For new installation, Frigidaire® PTAC Sleeves are available and recommended for proper installation. See accessories pages for sleeve options.*
• Standard PTAC installation requires 13-13/16" maximum wall thickness, unless a wall sleeve is used.
• If the PTAC unit protrudes more than 4", then it is suggested that it be installed with a subbase. See accessories pages for subbase options.
USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-866-942-1567 • frigidaire.com
CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-866-942-1567 • frigidaire.ca
FRP12PTT2R 08/11 © 2011 Electrolux Home Products, Inc.
Specifications subject to change.
Printed in the U.S.A.
Packaged Terminal Air Conditioner (PTAC)
FRP12PTT2R – Cool & Heat Pump with Electric Heat Back-up, 12,000 BTU
JOB:
LOCATION:
ENGINEER:
SUBMITTED TO:
REFERENCE: CONSTRUCTION:
APPROVAL: UNIT NUMBER:
DRAWING NUMBER: DATE:
SUBMITTED BY:
Features
• SilentDesign™
• Energy-Saver Option
• Eco-Friendly with R410a Refrigerant
• Ready-Select® Controls with
LED Temperature Display
• Effortless™ Temperature Control
• Versatile Multi-Mode Operation
• Effortless™ Operation
• Multi-Speed Fan
• 24 Hour On/Off Timer
• Effortless™ Maintenance
• Effortless™ Protection
• Comfort Control Design
• Smart Self-Check
• Front desk Control Ready
• Cord included (LCDI 6-20P)
• Commercial Grade Warranty
Dimensions
Height: 16˝
Width: 42˝
13 /
16
˝
Unit Weight: 111 Lbs.
Shipping Weight: 135 Lbs.
Max Wall Thickness: 13 13 /
16
˝
Cut-Out Height: 16 5 /
16
˝
Cut-Out Width: 42 3 /
16
˝
PERFORMANCE
BTU (Cool)
BTU (Heat Pump)
BTU (Heat - Electric)
EER (Cooling)
COP (Heat Pump)
Dehumidification (Pints/Hr.)
Approximate Cooling Area (Sq. Ft.)
Performance Certification
Safety Certification
Commercial Grade Warranty
ELECTRICAL
Volts/Hertz
Amps (Cool)
Watts (Cool)
Amps (Heat Pump)
Watts (Heat Pump)
Amps (Heat - Electric)
Watts (Heat - Electric)
Circuit Breaker
NEMA Plug Type
12,000/11,800
10700 / 10500
10,200/8,300
10.7/10.5
3.1/3.1
2.7
640
AHRI & CEC
UL, CUL & CSA
1 Year Full/5 Year Sealed
230/208V/60Hz
5.1/5.3
1120/1120
4.5/4.7
1010 / 990
13.2/12.2
3000/2452
20A
LCDI 6-20P
SPECIFICATIONS
Refrigerant
Charge (Oz.)
Noise Level Indoors (High/Med/Low) (dB)
Air Volume (CFM) (High/Med/Low)
Motor RPM (High/Med/Low)
Air Direction Control
UPC Code
FEATURES
Fin Coating
Air Intake
Low-Voltage Start-up
Auto Fan
Energy Saver
24 Hour On/Off Timer
Room Freeze Protection
Random Restart Protection
Quiet Start-up
Indoor Fan Speeds
LED Display
R410A
26.8
53/52/51
315/295/276
1100/1000/920
Auxiliary 2-way
0-12505-27603-3
Normal
Fresh or Recycled
Yes
Yes
Yes
Yes
Yes
Yes
Yes
3
Yes
ACCESSORIES – A complete line of accessories is available for each Frigidaire PTAC model. For more details please contact our Commercial Call Center at 1-866-942-1567.
F11FRP12PTT2RSS
Packaged Terminal
Air Conditioner (PTAC)
ACCessories
Metal Wall Sleeves and Accessories
The electro-galvanized steel used to make this metal sleeve resists corrosion. The white powder coating matches the color of the Frigidaire®
PTAC. sliding keyhole grille attachments at the back enable easy, oneperson installation from the inside.
5304482701 — Steel Wall Sleeve, Insulated
This extended width wall sleeve is fully insulated and made of galvanized steel. it is welded and protected with baked-on enamel. Welded areas are protected with a sealing compound to prevent rust.
5304483759 — Metal Wall Sleeve Extension, Insulated, 16"
5308815304 — Metal Wall Sleeve Extension, Insulated, 18"
5308815305 — Metal Wall Sleeve Extension, Insulated, 24"
5304483760 — Metal Wall Sleeve 3" Adapter
Polymer Wall Sleeves
The universal polymer wall sleeve utilizes fiberglass reinforced polyester compound to produce a durable, non-corrosive, wall case that provides superior sound absorption, reduces heat loss, and prevents sleeve sweating.
5308815302 — Polymer Wall Sleeve, Insulated
5308815301 — Polymer Wall Sleeve, Non-Insulated
Polymer Grilles
The polymeric architectural outdoor grille blends with most building exteriors. its durable design offers protection, has an enhanced appearance and provides superior weather resistance.
5308815310 — Polymer Architectural Outdoor Grille, Brown
5308815312 — Polymer Architectural Outdoor Grille, Alpine
Aluminum Grilles
The extruded aluminum outdoor grille will enhance the appearance of any building. The grilles are made of a durable, anodized aluminum that resists weather. installs easily onto the Frigidaire® metal wall sleeve, thanks to the sliding keyhole attachment.
5304480558 — Architectural Aluminum Outdoor Grille, Clear
5308815313 — Architectural Aluminum Outdoor Grille, Dark Brown
530448055X — Architectural Aluminum Outdoor Grille, Customized Color
5304480557 — Stamped Aluminum Outdoor Grille, Clear
5304484585 — Baffle Kit
Universal Drain Kit
The condensate drain kit is used to control condensate water from the packaged terminal unit. This universal drain kit can be used for exterior or interior drain systems.
5304480570 — Condensation Universal Drain Kit, 1 Pack
Fr_PTAC_ACC 08/11
Packaged Terminal
Air Conditioner (PTAC)
ACCessories
Air Filters
in order to ensure a healthy room environment the air filters should be changed periodically. By changing the air filters, airflow, temperature control and energy efficiency is maintained.
5304482892 — Air Filters, 10 Pack
Electrical Subbases
The electrical subbase provides the same features as the non-electrical subbase, plus a factory-installed electrical junction box containing a receptacle for corded packaged terminal air conditioner units.
5304482886 — Electrical Subbase-230V-15A, Black
5304482887 — Electrical Subbase-230V-20A, Black
5304482888 — Electrical Subbase-230V-30A, Black
5304482889 — Electrical Subbase-265V-15A, Black
5304482890 — Electrical Subbase-265V-20A, Black
5304482891 — Electrical Subbase-265V-30A, Black
5304482698 — Subbase Disconnect Switch, 265V
Decorative Subbases & Supports
The non-electrical subbase is made of heavy gauge steel to provide support for the wall sleeve. The subbase is designed to mount directly to the wall sleeve. Leveling legs attach easily to the wall sleeve and offer accurate leveling and support for units.
5308815315 — Decorative Subbase, Black
5304480575 — Leveling Legs
Hardwire Kits
Hardwire kits allow your PTAC to be permanently connected to a power source. The kit includes a 36" metal conduit and connector.
5304482696 — Hardwire Kit, 20 Amps
5304482697 — Hardwire Kit, 30 Amps
Wireless Wall Thermostats
The wireless effortless™ Temperature Control wall thermostat allows control without having to worry about wiring. easy to install and easy to use. Large intuitive LCD screen improves the user interaction.
5304482699 — Wireless Digital Thermostat, Non-Programmable
5304482XXX — Antenna for Wireless Wall Thermostat
Wired Digital Wall Thermostats
With the effortless™ Temperature Control wired wall thermostat, comfort and precision is in your hands. Programmable or nonprogrammable, this thermostat offers autochangeover, 2-stage heating and cooling, as well as emergency heating mode
(for Heat Pump).
5304482700 — Wired Digital Wall Thermostat, Programmable
5304483050 — Wired Digital Wall Thermostat, Non-Programmable
5304484139 — Transfer Cable (For Quick Programming of
Wired Thermostats)