Frigidaire FRP12PTT2A Product Specifications Sheet

Add to my manuals
6 Pages

advertisement

Frigidaire FRP12PTT2A Product Specifications Sheet | Manualzz

Packaged Terminal Air Conditioner (PTAC)

FRP12PTT2R

Air Conditioner / 

Heat Pump /

Backup Electric Heater

Product Dimensions

Height

Width

Depth

16"

42"

13-13/16"

More Easy-To-Use Features

Comfort Control Design

Simple controls allow guests to customize their settings, while quiet, uniform air movement keeps rooms comfortable.

Smart Self-Check

Provides nine diagnostic points for selfcheck and correction of fault conditions.

Eco-Friendly

Frigidaire® uses R-410A refrigerant that’s not harmful to the earth’s ozone layer and meets U.S. Environmental Protection

Agency requirements.

Effortless™ Operation

Simple, intuitive room controls are easy for guests to operate — ensuring a relaxing, more comfortable stay. Features like Effortless™ Restart and Ready-Select® controls reduce maintenance calls.

Performance

Cool

Backup Electric Heater

Heat Pump

BTUs

12,000 / 11,800

10,200 / 8,300

10,700 / 10,500

Signature Features

SilentDesign™

Sound reduction package.

Energy-Saver Option

This function effortlessly maximizes energy efficiency while keeping guests comfortable.

Effortless™ Maintenance

With Frigidaire’s reputation for durability, easy maintenance, availability of reliable parts and service you can count on, you can be sure that you’re getting the highest-quality performance.

Effortless™ Temperature

Control

Frigidaire® air conditioners maintain the preset room temperature so the room remains comfortable at all times and helps control energy levels. frigidaire.com

Packaged Terminal Air Conditioner (PTAC)

FRP12PTT2R Air Conditioner / Heat Pump / Backup Electric Heater

Performance

BTU (Cool)

BTU (Backup Electric Heater)

BTU (Heat Pump)

Dehumidification (Pints / Hour)

Cool Area (Sq. Ft.)

Energy Efficiency Ratio

Electrical

Volts

Amps (Cool)

Amps (Backup Electric Heater)

Amps (Heat Pump)

Watts (Cool)

Watts (Backup Electric Heater)

Watts (Heat Pump)

Cable Included

Length of Power Cord

Circuit Breaker

Plug Type (NEMA)

Features

12,000 / 11,800

10,200 / 8,300

10,700 / 10,500

2.7

1,010 / 990

Yes

5.5'

20A

LCDI (6-20P)

A

F R

640

10.7 / 10.5

Frigidaire

Room

RAC P-TAC Models

Frigidaire Baseline

1,120 / 1,120

3,000 / 2,452

Electronic Controls

Front Desk Control Ready

Fan Speeds (Cool / Fan / Heat)

Ready-Select® Controls

Yes

3 / 3 / 3

Noise Level Indoors (High / Med / Low)

Quiet Start-Up

53 /52 / 51

Yes

Low Voltage Start-Up

Random Restart Protection

Effortless™ Auto Freeze Protection

Energy Save

24-Hour On / Off Timer

Air CFM (High / Med / Low)

Air Direction Control

Air Intake

Filter Type

Filter Access

Fin Coating

Slide-Out Chassis

Commercial Grade Warranty 1

Yes

Yes

Yes

Yes

Yes

315 / 295 / 275

Auxiliary 2-Way

Fresh or Recycled

Nylon Mesh

Slide-Out

Normal

Yes

Yes

Certifications

Safety Certification

Performance

Specifications

UL, CUL & CSA

AHRI & CEC

Refrigerant

Charge

Shipping Weight (Approx.)

R410a

26.8 oz.

135 Lbs.

1 Warranty 5 year sealed system / 1 year full parts and labor.

C

P

PTAC Nomenclature

90 E T T 2 R

PTAC

BTU

77= 7,700

90= 9,000

12= 12,000

15= 15,000

Voltage

2= 230/208V

3= 265V

Design Year

T= 2010

U= 2011

Platform

Heat Type

E= Electric

P= Heat Pump

R= Normal no accessories

A= Seacoast no accessories

S= Normal w/ accessories

B= Seacoast w/ accessories

B

Plug Type (NEMA)

6-20P

NOTE: For planning purposes only. Always consult local and national electric codes. Refer to Product

Installation Guide for detailed installation instructions on the web at frigidaire.com.

Product Dimensions

A - Height

B - Width

C - Depth

Max. Wall Thickness

16"

42"

13-13/16"

13-13/16" 2

2 Unless the PTAC unit is installed with a wall sleeve.

Wall Cutout Dimensions

Height

Width

16-5/16"

42-3/16"

Accessories information available on the web at frigidaire.com

USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-866-942-1567 • frigidaire.com

CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-866-942-1567 • frigidaire.ca

FRP12PTT2R 08/11 © 2011 Electrolux Home Products, Inc.

Specifications subject to change.

Printed in the U.S.A.

PTAC - Heat Pump and Electric Heat models_Prod Specs

Packaged Terminal Air Conditioner (PTAC)

FRP12PTT2R Air Conditioner / Heat Pump / Backup Electric Heat

Rearward Slope

Wall Sleeve

Adapter 1/4 " Slope

Front Panel

Accessory

Outdoor Grille

Accessory

Wall Sleeve

Outside Wall Inside Wall

Chassis

Product Dimensions

Height

Width

Depth

Max. Wall Thickness

16"

42"

13-13/16"

13-13/16"

Wall Cutout Dimensions

Height

Width

16-5/16"

42-3/16"

Manufacturer Wall Sleeve Part Number

Amana

PTAC Specifications Trane

• Product Shipping Weight (approx.) – 135 Lbs.

• An electrical supply with grounded three-prong receptacle is required.

The power supply circuit must be installed in accordance with current edition of National Electrical Code (ANSI/NFPA 70) and local codes & ordinances.

• Voltage Rating – 230V / 208V / 60 Hz / 20 Amps

• Amps @ 230/208V Volts = (Cool) 5.1 / 5.3 Amps / (Backup Electric

Heater) 13.2 / 12.2 Amps / (Heat Pump) 4.5 / 4.7 Amps

Always consult local and national electric codes.

• Recommended Circuit Breaker – 20 Amps

• Unit equipped with 230/208V 3-wire power supply cord, NEMA plug

• type 6-20P, approximately 66" long.

In order for condensate water to drain properly inside the unit, the sleeve must be installed properly: Level from right to left with a slight

1/4" rearward pitch from the indoor side to the outdoor side as shown in the illustration above. Refer to the Installation Instructions on the web.

• The drain kit listed on the Frigidaire® PTAC Accessories page can be used for an internal or external drain. This applies to new and replacement installation.

General Electric

Metal Sleeve RAB71

Plastic Sleeve RAB77

Metal Sleeve WS900B

Plug Type (NEMA)

6-20P

Replacement Installation

• When replacing existing PTAC with new unit, refer to Product

Installation Guide on web to identify existing wall-sleeve manufacturer and size compatibility. If proper installation and slope are suspect, then correct installation of Frigidaire® PTAC Sleeve options recommended.

• For any sleeve retrofit application, be sure that the foam seals

(factory-installed on the tube sheets) provide a good seal between the grille and the outdoor coil tube sheets. These foam seals provide a barrier that stops air from the inside mixing with air on the outside

(known as air recirculation).

• Using Frigidaire® wall sleeve with Non-Frigidaire grille requires installation of an Accessory Baffle Kit, which ensures a good seal between the unit and exterior grille to prevent air recirculation. Air recirculation is a large contributor to performance loss and premature damage to major components.

Note: For planning purposes only. Refer to Product Installation Guide on the web at frigidaire.com for detailed instructions.

*See Frigidaire® PTAC accessories pages attached for optional accessories.

New Installation

• For new installation, Frigidaire® PTAC Sleeves are available and recommended for proper installation. See accessories pages for sleeve options.*

• Standard PTAC installation requires 13-13/16" maximum wall thickness, unless a wall sleeve is used.

• If the PTAC unit protrudes more than 4", then it is suggested that it be installed with a subbase. See accessories pages for subbase options.

USA • 10200 David Taylor Drive • Charlotte, NC 28262 • 1-866-942-1567 • frigidaire.com

CANADA • 5855 Terry Fox Way • Mississauga, ON L5V 3E4 • 1-866-942-1567 • frigidaire.ca

FRP12PTT2R 08/11 © 2011 Electrolux Home Products, Inc.

Specifications subject to change.

Printed in the U.S.A.

Packaged Terminal Air Conditioner (PTAC)

FRP12PTT2R – Cool & Heat Pump with Electric Heat Back-up, 12,000 BTU

JOB:

LOCATION:

ENGINEER:

SUBMITTED TO:

REFERENCE: CONSTRUCTION:

APPROVAL: UNIT NUMBER:

DRAWING NUMBER: DATE:

SUBMITTED BY:

Features

• SilentDesign™

• Energy-Saver Option

• Eco-Friendly with R410a Refrigerant

• Ready-Select® Controls with

LED Temperature Display

• Effortless™ Temperature Control

• Versatile Multi-Mode Operation

• Effortless™ Operation

• Multi-Speed Fan

• 24 Hour On/Off Timer

• Effortless™ Maintenance

• Effortless™ Protection

• Comfort Control Design

• Smart Self-Check

• Front desk Control Ready

• Cord included (LCDI 6-20P)

• Commercial Grade Warranty

Dimensions

Height: 16˝

Width: 42˝

13 /

16

˝

Unit Weight: 111 Lbs.

Shipping Weight: 135 Lbs.

Max Wall Thickness: 13 13 /

16

˝

Cut-Out Height: 16 5 /

16

˝

Cut-Out Width: 42 3 /

16

˝

PERFORMANCE

BTU (Cool)

BTU (Heat Pump)

BTU (Heat - Electric)

EER (Cooling)

COP (Heat Pump)

Dehumidification (Pints/Hr.)

Approximate Cooling Area (Sq. Ft.)

Performance Certification

Safety Certification

Commercial Grade Warranty

ELECTRICAL

Volts/Hertz

Amps (Cool)

Watts (Cool)

Amps (Heat Pump)

Watts (Heat Pump)

Amps (Heat - Electric)

Watts (Heat - Electric)

Circuit Breaker

NEMA Plug Type

12,000/11,800

10700 / 10500

10,200/8,300

10.7/10.5

3.1/3.1

2.7

640

AHRI & CEC

UL, CUL & CSA

1 Year Full/5 Year Sealed

230/208V/60Hz

5.1/5.3

1120/1120

4.5/4.7

1010 / 990

13.2/12.2

3000/2452

20A

LCDI 6-20P

SPECIFICATIONS

Refrigerant

Charge (Oz.)

Noise Level Indoors (High/Med/Low) (dB)

Air Volume (CFM) (High/Med/Low)

Motor RPM (High/Med/Low)

Air Direction Control

UPC Code

FEATURES

Fin Coating

Air Intake

Low-Voltage Start-up

Auto Fan

Energy Saver

24 Hour On/Off Timer

Room Freeze Protection

Random Restart Protection

Quiet Start-up

Indoor Fan Speeds

LED Display

R410A

26.8

53/52/51

315/295/276

1100/1000/920

Auxiliary 2-way

0-12505-27603-3

Normal

Fresh or Recycled

Yes

Yes

Yes

Yes

Yes

Yes

Yes

3

Yes

ACCESSORIES – A complete line of accessories is available for each Frigidaire PTAC model. For more details please contact our Commercial Call Center at 1-866-942-1567.

F11FRP12PTT2RSS

Packaged Terminal

Air Conditioner (PTAC)

ACCessories

Metal Wall Sleeves and Accessories

The electro-galvanized steel used to make this metal sleeve resists corrosion. The white powder coating matches the color of the Frigidaire®

PTAC. sliding keyhole grille attachments at the back enable easy, oneperson installation from the inside.

5304482701 — Steel Wall Sleeve, Insulated

This extended width wall sleeve is fully insulated and made of galvanized steel. it is welded and protected with baked-on enamel. Welded areas are protected with a sealing compound to prevent rust.

5304483759 — Metal Wall Sleeve Extension, Insulated, 16"

5308815304 — Metal Wall Sleeve Extension, Insulated, 18"

5308815305 — Metal Wall Sleeve Extension, Insulated, 24"

5304483760 — Metal Wall Sleeve 3" Adapter

Polymer Wall Sleeves

The universal polymer wall sleeve utilizes fiberglass reinforced polyester compound to produce a durable, non-corrosive, wall case that provides superior sound absorption, reduces heat loss, and prevents sleeve sweating.

5308815302 — Polymer Wall Sleeve, Insulated

5308815301 — Polymer Wall Sleeve, Non-Insulated

Polymer Grilles

The polymeric architectural outdoor grille blends with most building exteriors. its durable design offers protection, has an enhanced appearance and provides superior weather resistance.

5308815310 — Polymer Architectural Outdoor Grille, Brown

5308815312 — Polymer Architectural Outdoor Grille, Alpine

Aluminum Grilles

The extruded aluminum outdoor grille will enhance the appearance of any building. The grilles are made of a durable, anodized aluminum that resists weather. installs easily onto the Frigidaire® metal wall sleeve, thanks to the sliding keyhole attachment.

5304480558 — Architectural Aluminum Outdoor Grille, Clear

5308815313 — Architectural Aluminum Outdoor Grille, Dark Brown

530448055X — Architectural Aluminum Outdoor Grille, Customized Color

5304480557 — Stamped Aluminum Outdoor Grille, Clear

5304484585 — Baffle Kit

Universal Drain Kit

The condensate drain kit is used to control condensate water from the packaged terminal unit. This universal drain kit can be used for exterior or interior drain systems.

5304480570 — Condensation Universal Drain Kit, 1 Pack

Fr_PTAC_ACC 08/11

Packaged Terminal

Air Conditioner (PTAC)

ACCessories

Air Filters

in order to ensure a healthy room environment the air filters should be changed periodically. By changing the air filters, airflow, temperature control and energy efficiency is maintained.

5304482892 — Air Filters, 10 Pack

Electrical Subbases

The electrical subbase provides the same features as the non-electrical subbase, plus a factory-installed electrical junction box containing a receptacle for corded packaged terminal air conditioner units.

5304482886 — Electrical Subbase-230V-15A, Black

5304482887 — Electrical Subbase-230V-20A, Black

5304482888 — Electrical Subbase-230V-30A, Black

5304482889 — Electrical Subbase-265V-15A, Black

5304482890 — Electrical Subbase-265V-20A, Black

5304482891 — Electrical Subbase-265V-30A, Black

5304482698 — Subbase Disconnect Switch, 265V

Decorative Subbases & Supports

The non-electrical subbase is made of heavy gauge steel to provide support for the wall sleeve. The subbase is designed to mount directly to the wall sleeve. Leveling legs attach easily to the wall sleeve and offer accurate leveling and support for units.

5308815315 — Decorative Subbase, Black

5304480575 — Leveling Legs

Hardwire Kits

Hardwire kits allow your PTAC to be permanently connected to a power source. The kit includes a 36" metal conduit and connector.

5304482696 — Hardwire Kit, 20 Amps

5304482697 — Hardwire Kit, 30 Amps

Wireless Wall Thermostats

The wireless effortless™ Temperature Control wall thermostat allows control without having to worry about wiring. easy to install and easy to use. Large intuitive LCD screen improves the user interaction.

5304482699 — Wireless Digital Thermostat, Non-Programmable

5304482XXX — Antenna for Wireless Wall Thermostat

Wired Digital Wall Thermostats

With the effortless™ Temperature Control wired wall thermostat, comfort and precision is in your hands. Programmable or nonprogrammable, this thermostat offers autochangeover, 2-stage heating and cooling, as well as emergency heating mode

(for Heat Pump).

5304482700 — Wired Digital Wall Thermostat, Programmable

5304483050 — Wired Digital Wall Thermostat, Non-Programmable

5304484139 — Transfer Cable (For Quick Programming of

Wired Thermostats)

Fr_PTAC_ACC 08/11