Furuno LS-6100 Operation Manual

Add to my manuals
47 Pages

advertisement

Furuno LS-6100 Operation Manual | Manualzz
6" ECHO SOUNDER
LS-6100
Your Local Agent/Dealer
9-52 Ashihara-cho,
Nishinomiya, Japan
Telephone :
0798-65-2111
Telefax :
0798-65-4200
All rights reserved.
Printed in Japan
FIRST EDITION : FEB. 2002
C
PUB.No. OME-23690
( DAMI ) LS-6100
: JUN. 10,2002
*00080926502*
*00080926502*
*00080926502*
*OME23690C00*
*OME23690C00*
*OME23690C00*
TABLE OF CONTENTS
FOREWORD ................................................iii
SYSTEM OVERVIEW...................................iv
1. OPERATION ............................................1
1.1 Control Description ..........................1
1.2 Turning the Power On/Off ................1
1.3 Adjusting Display Contrast,
Brilliance ..........................................2
1.4 Choosing a Display, Frequency........2
1.5 Menu Operating Procedure ..............5
1.6 Automatic Operation ........................5
1.7 Manual Operation ............................6
1.8 Choosing Picture
Advance Speed................................7
1.9 Measuring Depth..............................8
1.10 A-scope Display ...............................8
1.11 Suppressing Interference .................9
1.12 Suppressing Low Level Noise ..........9
1.13 Erasing Weak Echoes....................10
1.14 White Line......................................10
1.15 Waypoints ......................................10
1.16 PROG Key .....................................12
1.17 Picture Color (Hue) ........................13
1.18 Deep Gain......................................13
1.19 Alarms ...........................................13
1.20 Resetting Trip Distance ..................15
1.21 Setting the Draft .............................15
1.22 Gain Compensation .......................15
1.23 Setting Up Nav Data Displays ........16
2. SYSTEM & INSTALLATION MENUS .... 18
2.1 System Menu................................. 18
2.2 Installation Menu ........................... 20
3. MAINTENANCE,
TROUBLESHOOTING ............................ 22
3.1 Maintenance .................................. 22
3.2 Cleaning the Display Unit............... 22
3.3 Transducer Maintenance ............... 22
3.4 Replacing the Fuse........................ 22
3.5 Battery Voltage Alert ...................... 22
3.6 Troubleshooting ............................. 23
3.7 Diagnostics.................................... 23
3.8 Test Pattern ................................... 24
4. INSTALLATION ..................................... 25
4.1 Display Unit ................................... 25
4.2 Thru-hull Mount Transducer........... 25
4.3 Transom Mount Transducer ........... 27
4.4 Inside-hull Transducer ................... 29
4.5 Optional Triducer ........................... 30
4.6 Optional Water Temperature/Speed
Sensor ........................................... 34
4.7 Wiring ............................................ 34
4.8 IEC 61162-1 Data Sentences......... 36
SPECIFICATIONS .................................. SP-1
OUTLINE DRAWING
INTERCONNECTION DIAGRAM
SAFETY INSTRUCTIONS
Safety Instructions for the Operator
CAUTION
WARNING
Do no turn on the equipment with the
transducer out of water.
Do not open the equipment.
There are no uer-serviceable parts inside.
The transducer may be damaged.
Do not disassemble or modify the
equipment.
The picture is not refreshed when
picture advancement is stopped.
Fire, electrical shock or serious injury can
result.
Maneuvering the vessel in this condition
may result in a dangerous situation.
Immediately turn off the power at the
switchboard if the equipment is emitting
smoke or fire.
Use the proper gain setting.
Incorrect gain may produce wrong depth
indication, possibly resulting in a dangerous
situation. See "Adjusting the gain" on page
7 for details.
Continued use of the equipment can cause
fire or electrical shock. Contact a FURUNO
agent for service.
Do not maneuver the vessel based
on the depth indication alone.
NOTICE
Grounding may result.
The high quality LCD shows 99.99% of
its pixels. The remaining .01% may drop
out or brighten, due to the property of
the LCD, however this is not a sign of
malfunction.
Use the proper fuse.
Fuse rating is shown on the equipment.
Use of a wrong fuse can result in damage
to the equipment.
A warning label is attached to the equipment. Do not remove the label. If the
label is missing or damaged, contact
a FURUNO agent or dealer.
WARNING
To avoid electrical shock, do not
remove cover. No user-serviceable
parts inside.
i
Name: Warning Label (1)
Type: 86-003-1011-1
Code No.: 100-236-231
Safety Instructions for the Installer
WARNING
CAUTION
Turn off the power at the switchboard
before beginning the installation.
Do not install the equipment where
air bubbles and noise are present.
Fire or electrical shock can result if the
power is left on.
Performance will be affected.
The following are guidelines for
handling of the transducer cable.
Be sure no water leaks in at the transducer or sensor mounting location.
- Do not locate near oils and fuels.
- Locate it in a safe place.
- Do no paint the cable.
Water leakage can sink the vessel. Also
confirm that the transducer and sensor will
not loosen by ship's vibration. The installer
of the equipment is solely responsible for
the proper installation of the equipment.
FURUNO will assume no responsibility for
any damage associated with improper
installation.
The sheath of the cable is made of
chloroprene rubber (or polychloride
vinyl). For this reason do not paint
the cable.
Observe the following compass safe
distances to prevent interference to a
magnetic compass:
Use the specified power cable.
Use of other power cable may result in
fire.
Display
unit
ii
Standard
compass
Steering
compass
0.5 m
0.35 m
FOREWORD
A Word to LS-6100
Owners
Features
The FURUNO LS-6100 is a dual frequency
(50 kHz, 200 kHz) monochrome LCD echo
sounder. Comprised of a display unit and a
transducer, the LS-6100 displays
underwater conditions on a bright 6-inch
monochrome LCD.
Congratulations on your choice of the
FURUNO LS-6100 6” Echo Sounder. We
are confident you will see why the
FURUNO name has become synonymous
with quality and reliability.
The main features of the LS-6100 are
For over 50 years FURUNO Electric
Company has enjoyed an enviable
reputation for innovative and dependable
marine electronics equipment. This
dedication to excellence is furthered by our
extensive global network of agents and
dealers.
• Compact design permits installation
where space is limited.
• Bright 6-inch monochrome LCD gives
excellent readability even in broad
daylight.
• Wide variety of display modes: single
frequency, dual frequency, bottom-lock,
marker-zoom, bottom-zoom, and nav
data.
This equipment is designed and
constructed to meet the rigorous demands
of the marine environment. However, no
machine can perform its intended function
unless operated and maintained properly.
Please carefully read and follow the
recommended procedures for operation
and maintenance.
• Automatic function permits unattended
adjustment of range and gain. The range
scale and gain automatically change to
display the bottom in the darkest gray
tone on the lower half of the screen.
• User-programmable nav data displays
provide analog and digital nav data.
We would appreciate hearing from you, the
end-user, about whether we are achieving
our purposes.
• Alarms: Bottom, Fish (bottom-lock and
normal), Speed, Water Temperature and
Arrival. (Speed and arrival alarms require
appropriate sensor; water temperature
alarm requires water temperature data.)
Thank you for considering and purchasing
FURUNO equipment.
• A-scope display helps discern echo
amplitude.
• White line feature helps discriminate fish
lying near the bottom.
• Destination waypoint feature provides
range, bearing, and time-to-go to
destination waypoint.
• Waterproof construction permits
installation on open bridge.
iii
SYSTEM OVERVIEW
System configuration
Equipment lists
Standard supply
Name
Display Unit
Type
Code No.
Qty
Remarks
LS-6100
—
1
520-5PSD
000-015-204
Thru-hull mount
Transducer
520-5MSD
000-015-212
Thru-hull mount
Select
520-5PWD
000-015-126
Transom mount
one
525ST-MSD
000-015-263
Thru-hull mount
Triducer (transducer
plus spd/temp sensor) 525ST-PWD
000-015-261
Transom mount
• Tapping screw (4 pcs., 5 x 20 SUS304, 000-802-081)
Installation Materials
• Washer head screw B (4 pcs., M4 x 20 SUS304, 000-804-742)
(CP02-07000)
• Cable assy. (1 pc., MJ-A15A3F0003-030, 000-145-513)
Spare Parts
Fuse (1 pc., 61NM-125V, 1A, Code No. 000-145-864)
(SP02-04500)
Template
Type 02-139-1035-2, Code No. 100-298-502, 1 pc., for flush mount
Optional equipment
Name
Type
MJ-A15A7F0004-005
NMEA Cable
MJ-A15A7F0005-020
Conversion Cable
02S4147
Water Temperature & ST-02MSB
Speed Sensor
ST-02PSB
Inner Hull Kit
22S0191
Code No.
000-145-690
000-145-691
000-141-082
000-137-986
000-137-987
000-802-598
iv
Qty
1
1
1
Select
one
1
Remarks
0.5 m, for wind sensor
2 m, w/o +12V line
For spd/temp sensor
Thru-hull type
1. OPERATION
1.1 Control Description
Display unit
How to remove the hard cover
1.2 Turning the Power
On/Off
Place your thumbs at the center of the
cover, and then lift the cover while
pressing it with your thumbs.
Press the [POWER/BRILL] key more than
one second to turn on the power. The unit
beeps, the startup screen appears, and
then the equipment checks the ROM and
RAM for proper operation and displays
program number. (If “NG” (No Good)
appears, try to press any key except the
[POWER/BRILL] key to start operation.
However, the equipment may not work
properly. Contact your dealer.) You may
1
press any key after the completion of the
equipment check to start operation sooner.
Note 1 : Setting windows other than those
on menus are erased if there is no
operation within about seven seconds.
Note 2: When the power is reapplied after
turning off the equipment with minimum
brilliance, minimum brilliance will be set
after the equipment goes through its initial
start up. Adjust the brilliance as necessary.
6" ECHO SOUNDER
LS-6100
FURUNO ELECTRIC CO., LTD.
ROM : OK RAM : OK
Program No: 0252308-01.**
1.4 Choosing a Display,
Frequency
** Program version no.
Start-up screen
To turn off the power, press and hold down
the [POWER/BRILL] key until the screen
goes blank. The time remaining until power
is turned off is counted down on the screen.
Seven displays are available: single
frequency (50 or 200 kHz), dual frequency,
marker-zoom, bottom-zoom, bottom-lock,
and nav data (two displays).
1. Press the [MODE] key to show the
mode selection window.
Note: The example screens shown in this
manual may not match the screens you see
on your display. The screen you see
depends on your system configuration and
equipment settings.
MODE
SINGLE FREQ.
DUAL FREQ.
MARKER ZOOM
BOTTOM ZOOM
BOTTOM LOCK
NAV DATA-1
NAV DATA-2
50kHz
200kHz
1.3 Adjusting Display
Contrast, Brilliance
Mode selection window
1. Press the [POWER/BRILL] key
momentarily to show the
brilliance/contrast adjustment window.
Min
CONTST
Max
4
Min
BRILL
2. Press the [MODE] key again within
seven seconds to choose a mode. You
may also choose a mode with ▲ or ▼.
3. For modes other than DUAL FREQ,
choose frequency; press ◄ for 50 kHz;
► for 200 kHz.
4. Press the [MENU/ESC] key to close the
menu.
Max
9
Brilliance/contrast adjustment window
2. For contrast, press the [POWER/BRILL]
key to adjust contrast cyclically. (You
may also use ◄ or ► on the Cursor
Pad to adjust contrast.)
3. To adjust brilliance, use ▲ or ▼.
4. Press the [MENU/ESC] key to close the
brilliance/contrast adjustment window.
2
Single frequency display
Dual frequency display
50 kHz
The 50 kHz picture appears on the left; the
200 kHz picture on the right. This display is
useful for comparing the same picture with
two different transmitting frequencies.
The sounder uses ultrasonic signals to
detect bottom conditions. The lower the
frequency of the signal, the wider the
detection area. Therefore, the 50 kHz
frequency is useful for general detection
and judging bottom condition.
50/200
1/1
0.0 0
0
50 kHz
picture
200 kHz
picture
20
20
40
40
60
60
80
80
200 kHz
The higher the frequency of the ultrasonic
signal the better the resolution. For this
reason the 200 kHz frequency is ideal for
detailed observation of fish schools.
49.6
Dual frequency display
50 kHz
Marker-zoom display
200 kHz
This mode expands chosen area of the
normal picture to full vertical size of the
screen on the left-half window. You may
specify the portion to expand by operating
the VRM (Variable Range Marker), which
you can shift with ▲ or ▼. The area
between the VRM and zoom range marker
is expanded.
Frequency and coverage area
Picture Advance Speed
Mode
(AUTO or MANUAL)
Frequency
Single frequency display
17
Minute
Marker
(Shows time.
Each bar
is 30 sec.)
50k
0.0
40.7°F
16.2kt
Zoomed
fish
school 18
1/1
0
Nav Display
19
Level Bar
20
Fish
Transmission
School Line
Range Scale
10
Variable range
marker
17.0
This section
is zoomed
20
21
25.0
Bottom
22
30
40
Zoom marker
Marker-zoom display
60
49.6
Fish
school
20
40
Depth
50k
1/1
0.0 00
Marker-zoom display
80
Typical 50 kHz display
3
Bottom-zoom display
Nav data displays
This mode expands bottom and bottom fish
in the range width set with ZOOM RANGE
on page 3 of the SYSTEM menu. This
mode is useful for determining bottom
contour.
The nav data displays appear on the left
2/3 of the screen. Data other than depth
requires appropriate sensor.
You can display between two and four
items in a nav data display and choose the
item and order and to display them. See
paragraph 1.23 to choose the items to
display and “NAV DATA-1” and “NAV
DATA-2” in paragraph 2.1 to choose the
number of items to display.
50k
1/1
0.0 00
27
28
Single
frequency
display
10
29
Bottom
20
Zoom
marker
30
Depth
30
69.4m
31
29.8
32
Switched with
depth
40
Temperature
Bottom-zoom display
65.5°F
Bottom-zoom display
Odometer
Bottom-lock display
56nm
The bottom-lock display provides a normal
picture on the right half of the screen and a
15 feet (5 meter)* wide layer in contact with
the bottom is expanded onto the left half of
the screen. This mode is useful for
detecting bottom fish.
Trip meter
10.0nm
NAV DATA-1 display
XTE
* = Operator selectable
0.25nm
Bottom-lock display
50k
5
Zoomed
fish
4
1/1
00
10
3
20
1
Zoom
marker
Speed
This section
is zoomed
21.7
1
0
40
Single
frequency
display
0
0.5
1
60
50
40
30
20
10
kt
0
2
Fish 30
school
0.5
17.2
NAV DATA-2 display
Bottom displayed flat
Sample NAV DATA displays
Bottom-lock display
4
1.5 Menu Operating
Procedure
Off
Cruising
Fishing
The LS-6100 has three menus: Main menu
(referred to in text as “menu”), System and
Installation. Below is the basic menu
operating procedure.
Auto mode options window
4. Use ▲ or ▼ to choose option or set
numeric value.
5. Press the [MENU/ESC] key to close the
menu, or press ◄ to continue menu
operation.
1. Press the [MENU/ESC] key to open the
menu. Page 1 or Page 2 of the menu
appears depending on the page last
used.
1.6 Automatic Operation
P = Function of PROG key
P AUTO MODE
SHIFT
PIC. ADVANCE
NOISE LIMIT
CLUTTER
SIGNAL LEVEL
A-SCOPE
HUE
WHITE LINE
DEEP GAIN
How automatic operation works
Off
:
0ft
: 1/1
: Off
: Off
: Off
: Off
: Day
: Off
: Low
The automatic function automatically
chooses the proper gain, range scale and
clutter. It works as follows:
• The range changes automatically to
display the bottom echo on the screen.
• The gain is automatically adjusted to
display the bottom echo in the darkest
tone.
(1/2)
[MENU]: Exit
Note: SHIFT and CLUTTER are
not available in the auto mode.
• Clutter (on the menu), which suppresses
low-level noise, is automatically adjusted.
Page
no.
Menu, page 1
Choosing automatic operation
2. Use ▲ or ▼ to select an item. To view
page 2 of the menu, press ▼ to show
the display below.
The automatic mode provides two choices
of modes: cruising and fishing.
1. Press the [MENU/ESC] key to open the
menu.
2. Choose AUTO MODE from page 1 of
the menu.
3. Press ► to open the mode options
window.
4. Choose Cruising or Fishing as
appropriate.
GOTO WPT
Off
WAYPOINT LIST...
TRIP RESET?
GAIN ADJ 200
GAIN ADJ 50
DRAFT
: +0
: +0
: 0.0ft
SYSTEM MENU...
(2/2)
“Cruising” is for tracking the bottom;
“Fishing” is for searching fish schools.
Since “Cruising” uses a higher clutter
rejection setting than fishing, it is not
recommended for fish detection - weak
fish echoes may not be displayed.
“Fishing” clearly displays weaker
echoes.
[MENU]: Exit
Menu, page 2
3. Press ► to show selected item’s
options window. The example below
shows the options window for AUTO
MODE.
5
5. Press the [MENU/ESC] key to close the
menu.
1.7 Manual Operation
Choosing the manual mode
The auto mode in use is shown as
(Auto-Cruising) at
(Auto-Fishing) or
the top left corner on the screen.
1. Press the [MENU/ESC] key to open the
menu.
2. Press ▲ or ▼ to choose AUTO MODE
from page 1 of the menu.
3. Press ► to show the options window.
4. Choose Off with ▲.
5. Press the [MENU/ESC] key to close the
menu. “MANUAL” appears in reverse
video at the top left corner on the
screen.
Range offset
To display the bottom tail in detail in the
automatic mode, offset the range as below.
1. Press the [+] or [-] key of the [RANGE]
key.
Choosing range
AUTO RANGE OFFSET
+0 ft
The basic range and range shifting
functions used together give you the means
to choose the depth you can see on the
screen. The basic range can be thought of
as providing a “window” into the water
column and range shifting as moving the
“window” to the desired depth.
Auto range offset window
2. Press the [+] or [-] key of the [RANGE]
key again to choose offset desired
(range: -100 to +300 ft). Note that if the
range is changed the offset is returned
to “0”.
3. Press the [MENU/ESC] key to finish.
Gain offset
Shift
Gain offset lets your override automatic
gain adjustment.
1. Press the [GAIN] key.
Display
AUTO GAIN OFFSET
Min
±0
Range and display shift concept
Max
Choosing basic range
Auto gain offset window
The basic range may be chosen with the
[RANGE] key from the eight ranges shown
in the table on the next page. (“P/B” in the
table means Passi/Braza.)
2. Press ◄ or ► key to offset gain (setting
range –5 to +5). The gain selected is
shown at the top of the screen as
G (Gain) + (or -) XX (offset).
3. Press the [MENU/ESC] key to finish.
6
Table 1-1 Default ranges
Basic Range
4
5
6
40 80 150
120 200 400
20 40 80
30 50 100
Unit
1 2 3
meters
5 10 20
feet
15 30 60
fathoms 3 5 10
P/B
3 5 10
Adjusting the gain
The [GAIN] key adjusts the sensitivity of the
receiver. Generally, use a higher gain
setting for greater depths and a lower
setting for shallower waters.
7
8
200 300
600 1000
120 200
150 200
1. Press the [+] or [-] key of the [RANGE]
key and the display should now look
something like the one below.
2. Press the [+] or [-] key of the [RANGE]
key again to choose a basic range.
Gain too high Gain proper Gain too low
Examples of proper and improper gain
1000ft
600ft
400ft
200ft
120ft
60ft
30ft
15ft
1. Press the [GAIN] key and the display
shown below appears.
GAIN
Min
Basic ranges (default)
Shifting the range
Max
200k
2
50k
3
Gain adjustment window
The basic range may be shifted up or down
in the manual mode as follows:
2. When using the dual frequency display,
press ▲ or ▼ to choose frequency.
3. Press the [GAIN] key to set. (You may
also use ◄ or ►.) Adjust so that a slight
amount of noise remains on the screen.
4. Press the [MENU/ESC] key to close the
gain adjustment window.
1. Press the [MENU/ESC] key to open the
menu.
2. Choose SHIFT from page 1 of the
menu.
3. Press ► to open the shift options
window.
1.8 Choosing Picture
Advance Speed
0ft
The picture advance speed determines how
quickly the vertical scan lines run across
the screen. When choosing a picture
advance speed, keep in mind that a fast
advance speed will expand the size of the
fish school horizontally on the screen and a
slow advance speed will contract it. Note
that the picture is not refreshed when
picture advancement is stopped. Therefore,
use caution when steering the vessel under
this condition.
Shift window
4. Use ▲ or ▼ to choose amount of shift
desired.
5. Press the [MENU/ESC] key to close the
menu.
Note: The picture may not be displayed if
the amount of shift is greater than actual
depth.
7
50k
1/1
0
VRM
VRM depth 20
39.8
Fast
Slow
40
Picture and picture advancement speed
1. Press the [MENU/ESC] key to open the
menu.
2. Choose PIC. ADVANCE from page 1 of
the menu.
3. Press ► to show the options window.
60
49.6
80
How to measure depth with the VRM
(
Stop
1/16 Slow
1/8
1/4
1/2
1/1
2/1
4/1 Fast
1.10 A-scope Display
)
This display shows echoes at each
transmission with amplitudes and tone
proportional to their intensities, on the right
1/4 of the screen. It is useful for estimating
the kind of fish school and bottom
composition.
Picture advance options window
4. Use ▲ or ▼ to choose picture advance
speed desired. The fractions in the
options window denote the number of
scan lines produced per transmission.
For example, 1/8 means one scan line
is produced every 8 transmissions.
“Stop” freezes the display and it is
convenient for observing an echo.
5. Press the [MENU/ESC] key to close the
menu.
Note: In the dual frequency display, the
A-scope display is only available with the
high frequency display.
Single frequency display
50k
1/1
0
10
20
1.9 Measuring Depth
The VRM (Variable Range Marker)
functions to measure the depth to fish
schools, etc.
Weak
reflection
(fish or noise)
Strong
reflection
(fish)
30
32.3
1. Press ▲ or▼ to place the VRM on the
object which you wish to measure
range.
2. Read the VRM depth just above the
VRM.
40
A-scope display
A-scope display
8
Strong
reflection
(bottom)
1. Press the [MENU/ESC] key to open the
menu.
2. Press ▲ or ▼ to choose A-SCOPE
from page 1 of the menu.
3. Press ► to show the options window.
4. Press ▲ or ▼ to choose the A-scope
presentation type desired.
Normal: Display shows echoes at each
transmission with amplitudes and tone
proportional to their intensities
Peak: Peak-hold amplitude picture.
5. Press the [MENU/ESC] key to close the
menu.
6. To turn off the A-scope display,
choose Off at step 4 and then press the
[MENU/ESC] key.
Turn the noise limiter off when no
interference exists, otherwise weak echoes
may be missed.
1.12 Suppressing Low
Level Noise
Low intensity “speckles” may appear over
most of screen. This is mainly due to
sediment in the water or noise. These can
be suppressed by adjusting CLUTTER on
the menu. When the automatic mode is on,
clutter is automatically rejected. To
suppress low level noise in manual sounder
operation, do the following:
1. Press the [MENU/ESC] key to open the
menu.
2. Use ▲ or ▼ to choose CLUTTER from
page 1 of the menu.
3. Press ► to show the options window.
4. Use ▲ or ▼ to choose the degree of
suppression desired; 1, 2, 3 ,4, 5 or 6.
The higher the number the greater the
suppression.
5. Press the [MENU/ESC] key to close the
menu.
6. To turn off low-level noise
suppression, choose Off at step 4 and
then press the [MENU/ESC] key.
1.11 Suppressing
Interference
Interference from other acoustic equipment
operating nearby or other electronic
equipment on your boat may show itself on
the display as shown in the figure below.
To suppress interference, do the following:
1. Press the [MENU/ESC] key to open the
menu.
2. Use ▲ or ▼ to choose NOISE LIMIT
from page 1 of the menu.
3. Press ► to show the options window.
4. Use ▲ or ▼ to choose the degree of
suppression desired; Off, Low, Medium,
or High (highest).
5. Press the [MENU/ESC] key to close the
menu.
Clutter appearance
Interference from
other sounder
Electrical interference
Forms of interference
9
1.13 Erasing Weak
Echoes
50k
0.0
1/1
00
50k
Fish school 20
clearly shown
20
Sediment in the water or reflections from
plankton may be painted on the display in
low intensity tones.
1/1
00
40
40
White line
60
60
52.6
Weak
echoes
52.6
80
White Line OFF
m
80
White Line ON (Mesh)
How white line works
1.15 Waypoints
Appearance of weak echoes
Waypoints may be used to:
These weak echoes may be erased as
follows:
• Record the latitude and longitude position
of an important echo. 12 points may be
registered.
1. Press the [MENU/ESC] key to open the
menu.
2. Use ▲ or ▼ to choose SIGNAL LEVEL
from page 1 of the menu.
3. Press ► to show the options window.
4. Use ▲ or ▼ to choose the degree of
suppression desired; Off, Low, or High
(highest).
5. Press the [MENU/ESC] key to close the
menu.
6. To turn off the signal level function,
choose "Off" at step 4 and then press
the [MENU/ESC] key.
• Output a waypoint position to a plotter to
mark position on its screen
• Find range, bearing and time-to-go to a
location (waypoint)
Note: Requires latitude and longitude
position from a navigator.
Registering a waypoint on the
screen
1. Press the [MARK] key. The cursor
appears along with waypoint entry
instructions.
Note: If there is no position data the
message “No position data!” appears.
Check the navigator.
1.14 White Line
The white line feature displays a leading
edge of the bottom echo in white. This is
useful for discriminating bottom fish near
the bottom.
1/1
50k
0.0
0
WAYPOINT ENTRY
( Move) Cursor
[MARK] Enter
[MENU] Cancel
1. Press the [MENU/ESC] key to display
the menu.
2. Use ▲ or ▼ to choose WHITE LINE
from page 1 of the menu.
3. Press ► to show the options window.
4. Use ▲ or ▼ to choose Off, Tone or
Mesh as appropriate. “Mesh” paints the
white line in darker tone than “Tone.”
5. Press the [MENU/ESC] key to close the
menu.
20
Cursor
40
60
49.6
80
50 kHz display
10
2. Use ▲ or ▼ to set the cursor where
desired. Picture advancement is
stopped until step 3 is completed.
3. Press the [MARK] key again. The
latitude and longitude position at the
cursor is output to the navigator and a
vertical line marks location. Further, the
display shows the waypoint name (next
sequential number) and position of the
location selected at step 2.
Registering waypoint from the
waypoint list
1. Press the [MENU/ESC] key to open the
menu.
2. Use ▲ or ▼ to choose WAYPOINT
LIST from page 2 of the menu.
3. Press ►.
WAYPOINT LIST
0101
0203
03
---------------------------------------------[MENU]: Exit
WAYPOINT
Name FREQ.
05
Lat : 34°22.796'N
Lon : 136°07.264'E
Erase?
[MENU]: Exit
Waypoint data display
Waypoint list
4. Choose an empty waypoint and press
►. Press ► again.
Note: If you attempt to enter 13th
waypoint, the message “Memory full!”
appears. In this case, erase an
unwanted waypoint to enable entry.
NEW WAYPOINT
Name FREQ.
04------ ENT
05
Lat : 34°22.796'N
Lon : 136°07.264'E
4. Press the [MENU/ESC] key to save the
waypoint under the name shown, or go
to step 5 to change its name.
5. Press ► to open the waypoint name
entry window.
Erase?
[MENU]: Exit
WAYPOINT
Name FREQ.
01------ ENT
05
Lat : 34°22.796'N
Lon : 136°07.264'E
New waypoint window, name entry
5. Use ▲ or ▼ to set character; ◄ or ► to
shift cursor.
6. Press ► to select ENT.
7. Enter latitude and longitude, similar to
how you entered waypoint name
8. Press the [MENU/ESC] key to register
the waypoint.
Erase?
[MENU]: Exit
Waypoint window, name entry
6. Use ▲ or ▼ to set character; ◄ or ► to
shift cursor. The name may consist of
eight alphanumeric characters.
Setting destination waypoint
Note: Character order is
0→1…9→A→B…Z→0…
Set a destination waypoint to find range,
bearing and time-to-go to that point. You
can see range and bearing to a waypoint.
Time-to-go is shown on the Time to Go
digital display.
7. Press ► to choose ENT.
8. Press the [MENU/ESC] key to register
the waypoint.
1. Press the [MENU/ESC] key to open the
menu.
11
2. Use ▲ or ▼ to choose GOTO WPT
from page 2 of the menu.
3. Press ► to open the waypoints list.
7. Press ▲ to select YES to erase the
waypoint. The waypoint list appears,
with the erased waypoint blank.
8. Press the [MENU/ESC] key twice to
close the menu.
Off
01
02
03
04
---------------------------------------------------------
1.16 PROG Key
The [PROG] key provides for instant
display of a user-programmed options
window from page 1 of the menu
Waypoint list
Using the PROG key
4. Use ▲ or ▼ to choose a waypoint.
5. Press the [MENU/ESC] key to close the
menu.
1. Press the [PROG] key. The pop-up
window corresponding to the item
programmed appears. In the example
below the auto mode options (default
[PROG] key setting) is shown.
Editing waypoints
1. Press the [MENU/ESC] key to open the
menu.
2. Use ▲ or ▼ to choose WAYPOINT
LIST from page 2 of the menu.
3. Press ► to open the waypoints list.
4. Use ▲ or ▼ to choose a waypoint and
press ►.
5. Use ▲ or ▼ to choose the item to edit;
name, latitude or longitude.
6. Press ► to open the data entry window.
7. Use ▲ or ▼ to set character; ◄ or ► to
choose location.
8. Press ► to choose ENT.
9. Press the [MENU/ESC] key to close the
menu.
AUTO MODE
Off
Cruising
Fishing
Auto mode options window
2. Use ▲ or ▼ to select option or adjust
setting.
3. Press the [MENU/ESC] to close the
window.
Registering function
1. Press the [MENU/ESC] key to show the
menu.
2. Choose the item on page 1 of the menu
that you wish to use.
3. Press and hold down the [PROG] key
(about three seconds) until you hear a
beep. The “P” mark moves to item
selected.
4. Press the [MENU/ESC] key to close the
menu.
Erasing waypoints
1. Press the [MENU/ESC] key.
2. Use ▲ or ▼ to choose WAYPOINT
LIST from page 2 of the menu.
3. Press ► to open the waypoints list.
4. Use ▲ or ▼ to choose the waypoint to
erase, and then press ►.
Note: You cannot erase a waypoint
which is selected as “GOTO WPT.”
5. Press ▼ to choose “Erase.”
6. Press ► to open the options window.
12
1.17 Picture Color (Hue)
1.19 Alarms
Two picture color arrangements are
available: Day and Night. Day shows
echoes on a white background; Night
shows them on a black background.
Alarm description
The LS-6100 has six conditions which
generate both audio and visual alarms:
bottom alarm, normal fish alarm, bottom
lock fish alarm, water temperature alarm,
arrival alarm and speed alarm. (The water
temperature, arrival and speed alarms
require appropriate sensors.)
1. Press the [MENU/ESC] key to display
the menu.
2. Use ▲ or ▼ to choose HUE from page
1 of the menu.
3. Press ► to show the options window.
4. Use ▲ or ▼ to choose Day or Night as
appropriate.
5. Press the [MENU/ESC] key to close the
menu.
Bottom alarm: The bottom alarm alerts
you when the bottom is within the alarm
range set. To activate the bottom alarm the
depth must be displayed.
1.18 Deep Gain
Fish (normal) alarm: The fish (normal)
alarm tells you when fish are within the
preset alarm range.
“Deep Gain” compensates for propagation
attenuation of the ultrasonic waves. It does
this by equalizing echo presentation so that
fish schools of the same size appear in the
same density in both shallow and deep
waters. In addition, it reduces surface
noise.
Fish (bottom lock) alarm: The fish
(bottom lock) alarm, available with the
bottom-lock mode, sounds when fish are
within a certain distance from the bottom.
Note that the Fish (normal) alarm must be
turned on to use this alarm.
Water temperature alarm: The water
temperature alarm alerts when the water
temperature is within (Inside alarm) the
alarm range set or over the range set.
1. Press the [MENU/ESC] key to open the
menu.
2. Use ▲ or ▼ to choose DEEP GAIN
from page 1 of the menu.
3. Press ► to show to the options window.
4. Choose Low, Medium, or High as
appropriate. High provides the greatest
degree of gain reduction against short
range echoes.
5. Press the [MENU/ESC] key to close the
menu.
Speed alarm: The speed alarm alerts you
when the speed is within (Inside alarm) or
over (Outside alarm) the preset speed.
Arrival alarm: The arrival alarm alerts
when you are near a waypoint by the
distance set.
Activating an alarm
1. Press the [ALARM] key.
2. Press ▲ or ▼ to show page 1 or page 2
of the Alarm menu as appropriate.
13
8. Press ► to show the options menu.
ALARM
BOTTOM
FROM
RANGE
FISH(Normal)
FROM
RANGE
FISH(B/L)
FROM
RANGE
FISH LEVEL
On
:
5ft
:
10ft
: On
:
5ft
:
10ft
: On
:
8ft
: 1.0ft
: Medium
0ft
Depth
(1/2)
Page
no.
ALARM
SPEED
FROM
RANGE
ARRIVAL ALRM
RANGE
Inside
72.4°F
1.0°F
: Off
:
0.0kt
:
1.0kt
: Off
:
0.01nm
Temperature
Speed
Weak
Medium
Strong
(2/2)
[MENU]: Exit
Gray characters mean alarm is inactive.
Fish level options
Alarm menu
17. Use ▲ or ▼ to choose the echo
strength level which will trigger a fish
alarm:
3. Use ▲ or ▼ to choose BOTTOM,
FISH(Normal), FISH(B/L),
TEMPERATURE or SPEED as
appropriate.
4. Press ► to show the options menu.
Off
On
1.0 kt
Depth, temperature, speed setting window
9. Use ▲ or ▼ to set starting depth,
temperature or speed as appropriate.
10. Press ◄ to close the window.
11. Press ▼ to choose RANGE.
12. Press ► to show the options menu.
13. Use ▲ or ▼ to set alarm range.
14. For the bottom alarm, temperature
alarm, speed alarm and arrival alarm,
press the [MENU/ESC] key to finish.
For a fish alarm, press ◄ to close the
window, and then go to step 15.
15. Press ▼ to choose FISH LEVEL.
16. Press ► to show the options menu.
[MENU]: Exit
TEMPERATURE
FROM :
RANGE :
63.2°F
Weak: Weak echoes (weakest tone on
level bar)
Medium: Medium strength echoes
(middle tone on level bar)
Strong: Strong echoes (darkest tone on
level bar)
Off
Inside
Outside
Fish, Arrival, Temp, Speed
Bottom Alarm Alarm Types
On/Off
18. Press the [MENU/ESC] key to close the
menu.
Alarm options
5. Use ▲ or ▼ to choose alarm type:
Off: Alarm off
On: Alarm on
Inside: Alarm generated when speed
(water temperature) is within the range
set.
Outside: Alarm generated when speed
(water temperature) is outside the range
set.
6. Press ◄ to close the window.
7. Press ▼ to choose FROM.
14
Note: To reset the odometer to zero, clear
the memory.
Alarm icon*
Alarm range
Starting
point
1.21 Setting the Draft
The default depth display shows the
distance from the transducer. If you would
rather show the distance from the sea
surface, set your ship’s draft as follows:
Alarm range marker
l Bottom alarm, Fish alarm (normal): Right
l Fish alarm (bottom/lock): Left
1. Press the [MENU/ESC] key to open the
menu.
2. Use ▲ or ▼ to choose DRAFT from
page 2 of the menu.
3. Press ► and then use ▲ or ▼ to set
draft. The setting range is –15 to 50
(meters, feet).
4. Press the [MENU/ESC] key to close the
menu.
* Alarm icon
: Bottom alarm
: Fish alarm (normal)
: Fish alarm (B/L)
: Temperature alarm (°C or °F shown)
: Speed alarm
: Arrival alarm
How the alarm works
Note: To disable an alarm, choose Off at
step 5 in the above procedure.
Silencing the buzzer
1.22 Gain Compensation
The buzzer sounds and the appropriate
alarm icon appears and flashes when an
alarm is violated. You can silence the
buzzer by pressing the [ALARM] key.
However, the buzzer will sound whenever
the alarm setting is violated.
If the gain is too high or too low, or the gain
for the low and high frequencies appears
unbalanced, you can compensate it as
follows:
1. Press the [MENU/ESC] key to open the
menu.
2. Use ▲ or ▼ to choose GAIN ADJ 200
or GAIN ADJ 50 from page 2 of the
menu.
3. Press ► to show to the options window.
4. Use ▲ or ▼ to set the amount. The
setting range is –50 to +50.
5. Press the [MENU/ESC] key to close the
menu.
Note: The audio and visual alarms are
released against the last-violated alarm
when multiple alarms are active.
1.20 Resetting Trip
Distance
1. Press the [MENU/ESC] key to open the
menu.
2. Use ▲ or ▼ to choose TRIP RESET?
from page 2 of the menu.
3. Press ►.
4. Press ▲ to reset trip distance. Beeps
are generated while the trip distance is
being reset.
5. Press the [MENU/ESC] key to close the
menu.
15
1.23 Setting Up Nav Data
Displays
(6)
(7)
(8)
(4)
(2)
(9)
(5)
Three-data
Four-data
Two-data
display
display
display
Items displayable in (1) - (3): depth, position,
course, range and bearing, trip distance,
odometer, water temperature, heading,
air pressure, time-to-go to destination waypoint,
XTE*, speed*, wind speed and direction*,
destination waypoint data*, compass*
Items displayable in (4) - (9): depth, position,
course, range and bearing, trip distance,
odometer, water temperature, heading,
air pressure, time-to-go to destination waypoint,
XTE*, wind speed and direction
(1)
The user may arrange the nav data
displays as desired.
1. Use the [MODE] key to select the nav
data display you want to set up.
2. Press the Cursor Pad to display the
NAV DATA SETUP window.
NAV DATA SETUP
/ : Window Selection
/ : Data Selection
[MENU]: Exit
NAV DATA SETUP window
(3)
* = Graphic display
3. Use ▲ or ▼ to choose a data display
window desired. A dashed-line rectangle
circumscribes your selection.
4. Use ◄ or ► to choose item to display.
See the next page for a description of
the displays.
Nav data window and item displayable
5. Press the [MENU/ESC] key to finish.
Note: You can choose the number of items
to show in a nav data display with NAV
DATA-1 and NAV DATA-2 on the System
menu.
16
GRAPHIC DISPLAYS
DIGITAL DISPLAYS
Temperature
Depth
XTE
0.25
DEPTH
XTE scale
1
0.5
0
0.5
1
Heading
30° 00.065'N
130° 00.574'E
60
50
40
30
20
10
0
WATER TEMPERATURE
Position
XTE GRAPHIC
Speed
69.8°F
32.8ft
nm
318°
HEADING
POSITION
kt
Wind Speed
Speed
Speedometer
WIND SPEED
SPEED
SPEED GRAPHIC
Course
Wind
APP*
0
30
60
60
120°
90
Wind Dir.
123.0°
30
COURSE
Rng
Speed
10.3
Wpt 03
Rng 0.19nm
XTE 0.00nm
m/s
Air Pressure
Brg
0.5
Trip meter
Brg 321°
Cse 333°
0
1018hpa
RANGE & BEARING&
Bearing,
Course
Destination
waypoint
direction
1
0.5
XTE
scale
1
E
Cse
90°
Time to Go
00H30M
TRIP DISTANCE
TIME-TO-GO&
Odometer
56nm
Brg
30°
N
AIR PRESSURE
121nm
ODOMETER
DESTINATION WAYPOINT GRAPHIC
Bearing to
destination
waypoint
WIND DIRECTION
1.21nm 140°
150
WIND GRAPHIC
Destination
waypoint
data:
Name,
Range,
XTE
138°
120
180
APP*
90
120
150
APP*
8.0m/s
19.3kt
17.2
TRUE/MAG#
* APP or TRUE
depending on menu
setting.
# TRUE or MAG
depending on menu
setting.
&To destination
waypoint
Note 1: Nav data is updated with some delay.
Note 2: When data is lost 120 sec., the
display shows "- -" at the location where
Course
data is lost.
COMPASS GRAPHIC
Nav data displays
17
2. SYSTEM & INSTALLATION
MENUS
The System menu mainly consists of items
which once set do not require frequent
adjustment. You may display this menu by
choosing SYSTEM MENU at page 2 of the
menu and pressing ►.
PAGE 1
2.1 System Menu
Page 1
LANGUAGE: The system language is
available in English, several European
languages and Japanese. To change
language, select language desired and
press the [MENU/ESC] key.
SYSTEM MENU
LANGUAGE
English
DEPTH UNIT
SPEED UNIT
WIND UNIT
TEMP UNIT
: ft
: kt
: m/s
: °F
TEMP GRAPH
NAV DATA-1
NAV DATA-2
: Off
:
:
DEPTH UNIT: Choose unit of depth
measurement from meters, feet, fathoms,
passi/braza and hiro (Japanese).
KEY BEEP
: On
BATT VOLTAGE : Off
SPEED UNIT: Choose unit of speed
measurement from knots, miles per hour
and kilometers per hour. Requires speed
data.
(1/3)
[MENU]: Exit
Page no.
PAGE 2
SYSTEM MENU
NAV DISPLAY
NMEA0183
TLL OUTPUT
BEARING
WIND SPD/DIR
TRIP SOURCE
Temp/Speed
: Ver 2.0
: Off
: True
: Apparent
: Own
WIND UNIT: Choose unit of wind speed
measurement from m/s, kt, km/h, and mph.
Requires wind speed data.
TEMP UNIT: Choose unit of temperature
measurement; Celsius or Fahrenheit.
Requires temperature data.
TEMP SOURCE : Own
SPEED SOURCE : Own
TEMP CALIB.
: +0.0°F (±40)
SPEED CALIB. : +0% (±50)
Own speed
10.0 kt
Own temp
16.2°F
TEMP GRAPH: Turns the water
temperature display on or off. The
temperature scale range is 16° (°F) in
“Narrow”; 40° (°F) in “Wide”. Requires
water temperature data.
(2/3)
[MENU]: Exit
PAGE 3
SYSTEM MENU
BASIC RANGE1
RANGE2:
RANGE3:
RANGE4:
RANGE5:
RANGE6:
RANGE7:
RANGE8:
15 ft
30
60
120
200
400
600
1000 (7-1500)
ZOOM RANGE :
B/L
RANGE :
(Bottom Lock)
50k
0.0
63.8°F
16.2kt
80
Temperature
Scale
15 ft (7-150)
15 ft (10-30)
20
70
40
60
50
ZOOM MARKER: On
1/1
00
Temperature
Graph
60
(3/3)
40
[MENU]: Exit
52.6
System menus
m
80
Water temperature display (wide, °F)
18
NAV DATA-1, -2: Choose the number of
navigation data items to display on the nav
data displays, from two, three or four items.
Requires appropriate nav data.
WIND SPD/DIR: Choose the wind speed
and direction reference from true and
apparent. Requires wind sensor.
Apparent: The direction (in relation to
ship’s bow) and speed of the wind as it
appears to those on board, relative to the
speed and direction of the boat;
combination of the true wind and the wind
caused by the boat's movement.
True: The speed and direction (in relation
to ship’s bow) of the wind felt or measured
when stationary.
KEY BEEP: Turn key beep on or off.
BATT VOLTAGE: Turn the battery voltage
indication (appears at the top right corner
on the screen) on or off. When on it
replaces the picture advance speed
indication.
Page 2
TRIP SOURCE: Choose speed source for
the trip distance indication; Own
(transducer w/speed sensor or separate
speed sensor) or NMEA.
NAV DISPLAY: Choose the nav data to
display in the nav data window at the top
left-hand corner. You may choose from
temperature/speed, latitude/longitude,
range and bearing, course over ground, trip
distance or wind speed. Requires
appropriate nav data.
TEMP SOURCE: Choose source of water
temperature input; Off, Own (transducer
w/water temperature sensor or separate
temperature sensor), or NMEA.
40.7°F
16.2kt
SPEED SOURCE: Choose source of speed
input; Off, Own (transducer w/speed sensor
or separate speed sensor), or NMEA.
Requires speed data.
Nav window (water temperature and speed)
NMEA0183: Choose NMEA version of
navigator; Ver. 1.5, Ver. 2.0 or Ver. 3.0.
TEMP CALIB.: If the water temperature
sensor-generated water temperature
indication is wrong, you can correct it here,
when “Own” is selected as temperature
source. For example, if the water
temperature indication is 2° higher than
actual water temperature, enter -2. The
setting range is -40°F to +40°F.
TLL OUTPUT: Enables/disables output of
TLL (Target Latitude, Longitude) position
when the [MARK] key is operated. “TLL”
outputs latitude and longitude position.
“FURUNO-TLL,” available with connection
of navigator that can output FURUNO TLL,
outputs latitude and longitude, water
temperature, depth, etc.
SPEED CALIB.: If the speed
sensor-generated speed indication is wrong,
you can correct it here, when “Own” is
selected as speed source. For example, if
the speed indication is 10% lower than
actual speed, enter +10. The setting range
is –50% to +50%.
BEARING: Ship’s course and bearing to a
waypoint may be displayed in true or
magnetic bearing. Magnetic bearing is true
bearing plus (or minus) earth’s magnetic
deviation. Requires bearing data.
19
Page 3
2.2 Installation Menu
BASIC RANGE 1 - BASIC RANGE 8: Set
range of each of the eight basic ranges.
The installation menu contains items which
once set do not require frequent
adjustment.
Note 1: All default basic ranges are
restored whenever the depth unit is
changed. Therefore, change the depth unit
before changing the basic ranges.
1. Turn on the power while pressing the
[MENU/ESC] key. Continue pressing the
[MENU/ESC] key until the Installation
menu appears.
Note 2: A range may not be lower than the
range preceding it. For example, if basic
range 3 is 60 feet, basic range 4 must be
greater than 60 feet.
Installation Menu
SIMULATION
ZOOM RANGE: Choose the range to zoom
in the marker-zoom and bottom-zoom
modes. You may choose a range between
7 and 150 feet (2 and 50 meters).
On
TEST ...
LCD PATTERN ...
MEMORY CLEAR
NMEA PORT
NMEA MIX
GPS WAAS*
B/L RANGE: The expansion width for the
bottom-lock display can be chosen from 10
to 30 feet (3 and 10 meters).
: In/Out
: Off
: Off
SET BOTTOM LEVEL ..
* = Setting cannot be changed when
NMEA PORT setting is "IN/IN."
ZOOM MARKER: The zoom marker
appears in the normal, bottom marker and
bottom zoom displays and marks the area
which is expanded in the bottom marker
and bottom zoom pictures. You can turn the
marker on or off as desired.
Installation menu
SIMULATION: The simulation mode
provides, without connection of the
transducer, simulated operation of the
equipment, using internally generated
echoes. All controls are operative. The
message “SIM” appears at the top right
corner on the screen when the simulation
mode is active.
1. At the installation menu, press ► to
open the simulation mode options
window.
2. Press ▼ to choose “On” to turn on the
simulation mode.
3. Press the [POWER/BRILL] key about
three seconds to turn off the power.
4. Press the [POWER/BRILL] key to turn
on the power. “SIM” appears at the top
right corner of the display
5. To turn off the simulation mode, select
Off at step 2.
20
TEST: Conducts diagnostic tests. For
further details, see paragraph 3.7.
LCD PATTERN: Tests the LCD. For further
details, see paragraph 3.8
3. Press ▲ or ▼ to choose “WAAS-02”
(test signal). When the system becomes
operational (in 2003), set to “00”
(regular WAAS signal).
4. Turn off the power.
MEMORY CLEAR: The memory can be
cleared to start afresh with default menu
settings.
BOTTOM LEVEL: If the depth indication is
unstable in automatic operation, or the
bottom echo cannot be displayed in the
darkest gray tone by adjusting the gain
controls in manual operation, you may
adjust the bottom echo level detection
circuit, for both 50 kHz and 200 kHz, to
stabilize the indication. Generally, lower the
bottom level for inner hull installation where
the receive level is too low. If the bottom
level is too low it may be difficult to
discriminate fish from the bottom, resulting
in unstable depth indication. And if the
bottom level is too high the depth indication
may not appear.
1. At the installation menu, press ▼ to
choose MEMORY CLEAR.
2. Press ► to open the options window.
: YES
: NO
Clear memory display
4. Press ▲ to clear the memory. Beeps
are generated while the memory is
being cleared.
5. To restore normal operation, turn off the
power and then turn it on again.
NMEA PORT: Sets the function of the
NMEA port. For further details, see
paragraph 4.7.
1. At the installation menu, press ▼ to
choose SET BOTTOM LEVEL and then
press ►. Several seconds later the
following display appears.
NMEA MIX: Turns data mixing on or off.
For further details, see paragraph 4.7.
Bottom level
+0 (200k:
+0 ( 50k:
GPS WAAS: Chooses how to use the
WAAS signal.
-100 - +100 )
-100 - +100 )
Bottom level display
2. While observing the picture, use ▲ or ▼
to set 200 kHz; ◄ or ► to set 50 kHz.
Set up for optimum picture.
3. To restore normal operation, turn off the
power and then it on again.
Note: WAAS is currently in the
developmental phase. During the
developmental phase the reliability and
availability of the WAAS signal cannot be
guaranteed. Therefore, any position data
should be verified against other sources to
confirm reliability.
Note: The mode must be other than NAV
DATA to show the bottom level display.
1. Display the Installation menu.
2. Choose GPS WAAS and then press ►
to open the GPS WAAS options
window.
Off
WAAS options window
21
3. MAINTENANCE,
TROUBLESHOOTING
3.3 Transducer
Maintenance
WARNING
ELECTRICAL SHOCK HAZARD
Marine life on the transducer face will result
in a gradual decrease in sensitivity. Check
the transducer face for cleanliness each
time the boat is dry-docked. Carefully
remove any marine life with a piece of
wood or fine-grade sandpaper.
Do not open the equipment.
Only qualified personnel should work
inside the equipment.
3.1 Maintenance
Regular maintenance is essential for good
performance. Checking the items listed in
the table below monthly will help keep your
equipment in good shape for years to
come.
Checking
Item
3.4 Replacing the Fuse
The fuse in the power cable protects the
system from reverse polarity of the power
supply and equipment fault. If the fuse
blows, find the cause before replacing it.
Use only a 1A fuse (61NM-125V, 1A, or
equivalent FGBO-A, AC125V, 1A, Code No.
000-549-061). Using the wrong fuse will
damage the unit and void the warranty.
Action
Transducer
cable
Check cable for damage.
Power cable,
transducer
cable plug
Check that they are tightly
fastened. Refasten if
necessary.
Display unit
ground
Check for corrosion. Clean
if necessary.
Use the proper fuse.
Power supply
voltage
Check voltage. If out of
rating correct problem.
Fuse rating is shown on the equipment.
Use of a wrong fuse can result in fire and
damage the equipment.
WARNING
3.2 Cleaning the Display
Unit
3.5 Battery Voltage Alert
A battery icon appears when the battery
voltage is too high or too low.
Dust or dirt on the display unit can be
removed with a soft cloth. If desired, a
water-moistened cloth may be used. Use
special care when cleaning the LCD since it
scratches easily. Do not use chemical
cleaners to clean the display unit - they can
remove paint and markings.
Battery icon and meaning
Icon
Meaning
Voltage is lower than 10 VDC. If the
voltage goes below 9 V, the equipment
is automatically turned off.
Voltage is higher than 16.5 VDC. If the
voltage goes higher than 17.5 V, the
equipment is automatically turned off.
22
3.6 Troubleshooting
3.7 Diagnostics
The table below provides basic
troubleshooting procedures which the user
may follow to restore normal operation.
If you feel your unit is not working properly,
conduct the diagnostic test to find the
problem. If you cannot restore normal
operation, contact your dealer for advice.
Troubleshooting table
If…
neither echo nor
fixed range scale
appears
no echo appears
but the fixed
range scale
appears
1. Turn on the power while pressing the
[MENU/ESC] key. Continue pressing
the [MENU/ESC] key until the
Installation menu appears.
Then check …
•
•
•
•
•
battery voltage.
fuse.
power supply.
power cable.
Installation Menu
if display advance
speed is set to “Stop.”
• transducer plug
echo appears but
no zero line
• if range shifting is set
sensitivity is low
• gain setting.
• if air bubbles or marine
SIMULATION
TEST ...
LCD PATTERN ...
MEMORY CLEAR
to “0.”
NMEA PORT
NMEA MIX
GPS WAAS*
life is clinging to the
transducer face.
• if sediments are
present in the water.
• if the bottom is too soft
to return an echo.
there is extreme
interference or
noise
* = Setting cannot be changed when
NMEA PORT setting is "In/In."
Installation menu
2. Press▼ to choose TEST.
3. Press ► to start the test.
close to the engine.
• if the unit is properly
grounded.
• if other echo sounders
of the same frequency
as own are being
operated nearby.
• sensor plug.
the position
readout is
unrealistic or not
present
• the connection
: In/Out
: Off
: Off
SET BOTTOM LEVEL ..
• if the transducer is too
the speed/water
temperature
readout is
unrealistic or not
present
On
Level bar
ROM : OK
RAM : OK
NMEA :
Water
Temperature,
Speed
Battery Voltage
Temperature
inside display
unit
(Unit fixed at
°C.)
between sounder and
navigator.
• navigator.
Temp : 68.2°F
Speed : 10.0km/h
Power : 12.4 V
Body : 39°C
Program No. 0252308-01.**
Push [MENU] 3 times to exit.
** = Program version no.
Test display
23
4. The ROM, RAM and NMEA port are
checked, with the results shown as OK
or NG (No Good). For any NG, request
service. (A special connector is required
to test the NMEA port. Nothing appears
if no connector is connected.)
5. The squares at the right side of the test
display are for checking the controls.
Press each key and the arrows on the
Cursor Pad one by one. A control’s
corresponding on-screen square “lights”
in black if the control is normal.
6. To return to the Installation menu, press
the [MENU/ESC] key three times.
7. To restore normal operation, turn off the
power and turn it on again.
3.8 Test Pattern
This feature tests for proper display of
tones.
1. Turn on the power while pressing the
[MENU/ESC] key. Continue pressing the
[MENU/ESC] key until the Installation
menu appears.
2. Press▼ to choose LCD PATTERN.
3. Press ► to start the test. The entire
screen is black.
4. Press ► again and the screen turns
white.
5. Press ► again and the screen shows a
four-toned display.
6. Press ► again to return to the
Installation menu.
7. To restore normal operation, turn off the
power and then it on again.
BLACK
WHITE
Test patterns
24
FOUR-TONE
4. INSTALLATION
4.1 Display Unit
Flush mounting in a panel
Mounting considerations
See the instructions on the flush mounting
template (supplied).
The display unit can be installed on a
desktop, on the overhead or flush mounted
in a panel. When choosing a mounting
location keep the following in mind:
4.2 Thru-hull Mount
Transducer
• Keep the display unit out of direct
sunlight.
• The temperature and humidity should be
moderate and stable.
• Locate the unit away from exhaust pipes
and vents.
• The mounting location should be well
ventilated.
• Mount the unit where shock and vibration
are minimal.
• Keep the unit away from electromagnetic
field-generating equipment such as
motors and generators.
• For maintenance and checking purposes,
leave sufficient space at the sides and
rear of the unit and leave slack in cables.
• A magnetic compass will be affected if
placed too close to the display unit.
Observe the following compass safe
distances to prevent disturbance to the
magnetic compass:
Transducer mounting location
The thru-hull mount transducer (520-5PSD,
520-5MSD) provides the best performance
of all, since the transducer protrudes from
the hull and the effect of air bubbles and
turbulence near the hull skin is reduced.
When the boat has a keel, the transducer
should be at least 30 cm away from it.
Typical thru-hull mountings are shown in
the figure on the next page.
The performance of this sounder is directly
related to the mounting location of the
transducer, especially for high-speed
cruising. The installation should be planned
in advance, keeping the standard cable
length (8 m) and the following factors in
mind:
• Air bubbles and turbulence caused by
movement of the boat seriously degrade
the sounding capability of the transducer.
The transducer should, therefore, be
located in a position where water flow is
the smoothest. Noise from the propellers
also adversely affects performance and
the transducer should not be mounted
nearby. The lifting strakes are notorious
for creating acoustic noise, and these
must be avoided by keeping the
transducer inboard of them.
Standard compass: 0.5 meters
Steering compass: 0.35 meters
Desktop, overhead mounting
1. Fix the bracket to a desktop or the
overhead with tapping screws
(supplied).
2. Loosely screw knobs into the display
unit.
3. Set the display unit to the bracket and
then tighten the knobs.
• The transducer must always remain
submerged, even when the boat is rolling,
pitching or up on a plane at high speed.
25
• A practical choice would be somewhere
between 1/3 and 1/2 of the boat’s length
from the stern. For planing hulls, a
practical location is generally rather far
astern, so that the transducer is always in
water regardless of the planing attitude.
22
Typical thru-hull mount
transducer installations
Flat Washer
Rubber Washer
Fairing
Block
24
120
120
Hull
Deep-V Hull
28
30
Flat Washer
68
Hull
68
520-5PSD
Rubber
Washer
87
Unit: mm
520-5MSD
Cork
Washer
Thru-hull mount transducer mounting
dimensions (millimeters)
Flat Hull
Acceptable transducer mounting
locations
Typical thru-hull mount
transducer installations
Procedure for installing the
thru-hull mount transducer
1. With the boat hauled out of the water,
mark the location chosen for mounting
the transducer on the bottom of the hull.
2. If the hull is not level within 15° in any
direction, fairing blocks made out of teak
should be used between the transducer
and hull, both inside and outside, to
keep the transducer face parallel with
the water line. Fabricate the fairing
block as shown below and make the
entire surface as smooth as possible to
provide an undisturbed flow of water
around the transducer. The fairing block
should be smaller than the transducer
itself to provide a channel to divert
turbulent water around the sides of the
transducer rather than over its face.
l Position 1/2 to 1/3 of the hull
from stern.
l 15 to 30 cm off center line
(inside first lifting strakes.)
HIGH SPEED-V HULL
l Within the wetted bottom area
l Deadrise angle within 15°
Suitable transducer mounting locations
26
Hole for
stuffing tube
There are two methods of installation: flush
with hull (for flat hulls) and projecting from
hull (for deep V-hulls).
BOW
Upper Half
D
Lower Half
D>50 cm
Saw along slope
of hull.
Construction of fairing block
Flat Hull
3. Drill a hole just large enough to pass the
threaded stuffing tube of the transducer
through the hull, making sure it is drilled
vertically.
4. Apply a sufficient amount of high quality
caulking compound to the top surface of
the transducer, around the threads of
the stuffing tube and inside the
mounting hole (and fairing blocks if
used) to ensure watertight mounting.
5. Mount the transducer and fairing blocks
and tighten the locking nuts. Be sure
that the transducer is properly oriented
and its working face is parallel to the
waterline.
Deep-V
Hull
Transom mount transducer
mounting locations
Installing the transom mount
transducer on a flat hull
A suitable mounting location is at least 50
cm away from the engine and where the
water flow is smooth.
1. Drill four pilot holes in the mounting
location.
2. Attach the transducer to the bracket with
5 x 20 tapping screws (supplied).
3. Adjust the transducer position so the
transducer faces right to the bottom.
Note: Do not over-stress the stuffing tube
and locking nuts through excessive
tightening, since the wood block will swell
when the boat is placed in the water. It is
suggested that the nut be tightened lightly
at installation and retightened several days
after the boat has been launched.
Note: If necessary, to improve water
flow and minimize air bubbles staying
on the transducer face, incline the
transducer about 5° at the rear. This
may require a certain amount of
experimentation for fine tuning at high
cruising speeds.
4. Fill the gap between the wedge front of
the transducer and transom with epoxy
material to eliminate any air spaces.
4.3 Transom Mount
Transducer
The transom mount transducer
(520-5PWD) is very commonly employed,
usually on relatively small I/O or outboard
boats. Do not use this method on an
inboard motor boat because turbulence is
created by the propeller ahead of the
transducer.
27
5 x 20
5 x 20
5 x 20
5 x 20
M5 x 14
No.1
M5 x 14
No. 2
5°
Tape
Transom mount transducer,
mounted projecting from hull
Transom mount transducer,
mounting flush with hull
Transducer preparation
Installing the transom mount
transducer on a deep-V hull
Before putting the boat in water, wipe the
face of the transducer thoroughly with a
detergent liquid soap. This will lessen the
time necessary for the transducer to have
good contact with the water. Otherwise the
time required for complete “saturation” ill be
lengthened and performance will be
reduced.
This method is employed on deep-V hulls
and provides good performance because
the effects of air bubbles are minimal.
Install the transducer parallel with water
surface; not flush with hull. If the boat is
placed on a trailer care must be taken not
to damage the transducer when the boat is
hauled out of the water and put on the
trailer.
DO NOT paint the transducer. Performance
will be affected.
28
Attaching the transducer
4.4 Inside-hull
Transducer
1. Clean the transducer face to remove
any foreign material. Lightly roughen the
transducer face with #100 sandpaper.
Also, roughen the inside of the hull
where the transducer is to be mounted.
2. Warm the silicone sealant to 40°C
before usage to soften it. Coat the
transducer face and mounting location
with silicone sealant.
The thru-hull mount transducer (520-5PSD,
520-5MSD) may also be installed inside the
hull, following the procedure below.
Necessary tools
You will need the following tools:
• Sandpaper (#100)
• Silicone sealant
• Silicone grease
Transducer
Silicone
Sealant
Remarks on installation
• Turn off the engine and anchor the boat
while installing the equipment.
• Install the transducer in the engine room.
Coating transducer face
with silicone sealant
Choosing the mounting location
3. Press the transducer firmly down on the
hull and gently twist it back and forth to
remove any air which may be trapped in
the silicone sealant.
• Keep the following points in mind when
choosing a mounting location:
• The mounting location should be where
the hull is of single-hull thickness and is
void of air or flotation materials other than
solid fiberglass between the transducer
face and the water.
Checking the installation
1. Connect the battery to the display unit.
2. Turn on the display unit.
3. Press the [MODE] key to choose
SINGLE FREQ.
4. Choose 50 kHz or 200 kHz, and then
press the [MENU/ESC] key to close the
mode menu.
5. Press the [PROG] key to show the
pop-up window for automatic/manual
selection.
6. Press ▲to choose Manual.
7. Press the [MENU/ESC] key..
8. Press the [GAIN] key to set the gain to
“5” and then press the [MENU/ESC] key.
9. Press the [RANGE] key to set the range
to 10 meters (feet) and then press the
[MENU/ESC] key.
• Do not place the transducer over hull
struts or ribs which run under the hull.
• Avoid a location where the rising angle of
the hull exceeds 15°, to minimize the
effect of the boat’s rolling.
• You will finalize the mounting location
through some trial and error. The
procedure for this is shown later.
Centerline
1/2
1/3
50 cm
50 cm
15 cm
15 cm
Transducer
mounting
location
Inside-hull transducer mounting location
29
10. If the bottom is displayed in dark gray
and the depth indication appears, the
mounting location is suitable. Go to
“Final preparation.”
11. If the bottom is not displayed in dark
gray tone, the mounting location may be
unsuitable. Do the following:
a) Press the [POWER/BRILL] key to
turn off the power.
b) Gently dismount the transducer with
a piece of wood.
c) Reattach the transducer elsewhere
as shown in “Attaching the
transducer.”
d) Check the installation again.
525ST-PWD
The Transom Mount Transducer or
TRIDUCER® Multisensor with Integral
Release Bracket 525ST-PWD is
manufactured by AIRMAR Co. These
instructions are included with the sensor.
Pre-test for speed and temperature
Connect the sensor to the instrument and
spin the paddlewheel. Check for a speed
reading and the approximate air
temperature. If there is no reading, return
the sensor to your place of purchase.
Tools and materials needed
Final preparation
Scissors
Masking tape
Safety goggles
Dust mask
Electric drill
Drill bit for:
Bracket holes: 4mm, #23, or 9/64”
Fiberglass hull: chamfer bit (preferred),
6mm, or 1/4”
Transom hole: 19mm or 3/4” (optional)
Cable clamp holes: 3mm or 1/8”
Screwdrivers
Straight edge
Marine sealant
Pencil
Zip-ties
Water-based antifouling paint (mandatory
in salt water).
Support the transducer with a piece of
wood to keep it in place while it is drying.
Let the transducer dry 24-72 hours.
4.5 Optional Triducer
525ST-MSD
The optional triducer 525ST-MSD is
designed for thru-hull mounting. For how to
install this transducer see paragraph 4.2.
φ79 mm
Mounting location
133 mm
2.00"-12 UN
threads
φ51 mm
27 mm
To ensure the best performance, the sensor
must be submerged in aeration-free and
turbulence-free water. Mount the sensor
close to the centerline of the boat. On
slower heavier displacement hulls,
positioning it farther from the centerline is
acceptable.
7 mm
140 mm
Allow adequate space above the bracket
for it to release and rotate the sensor
upward.
Triducer 525ST-MSD
30
Height without
speed sensor
191mm (7-1/2")
Height with
speed sensor
213mm (8-1/2")
P66 Installation template
for starboard side of boat
Height
Drill at locations labeled "B"
for the following transom angles:
16° through 22°
Height required at mounting location
Note 1: Do not mount the sensor in an area
of turbulence or bubbles: near water intake
or discharge openings; behind strakes,
struts, fittings, or hull irregularities; behind
eroding paint (an indication of turbulence).
Note 2: Avoid mounting the sensor where
the boat may be supported during trailering,
launching, hauling, and storage.
Note 3: For single drive boat, mount on
the starboard side at least 75 mm
(3”) beyond the swing radius of the
propeller.
B
B
B
A
A
A
Drill at locations labeled "A"
for the following transom angles:
2° through 15°
Align arrow with bottom of transom
Align template vertically.
Deadrise angle
Slope of hull
parallel to
waterline
Align template arrow with
bottom edge of transom.
Positioning the template
75 mm(3")
minimum beyond
swing radius
Warning: Always wear safety goggles
and a dust mask.
3. Using a 4 mm, #23, or 9/64” bit, drill
three holes 22 mm (7/8”) deep
at the locations indicated. To prevent
drilling too deeply, wrap masking tape
around the bit 22 mm (7/8”) from the
point.
Fiberglass hull: Minimize surface
cracking by chamfering the gelcoat. If a
chamfer bit or countersink bit is not
available, start drilling with a 6mm or
1/4” bit to a depth of 1 mm (1/16”).
4. If you know your transom angle, the
bracket is designed for a standard 13°
transom angle.
11°-18° angle: No shim is required. Skip
to step 3 in “Adjusting”.
Other angles: The shim is required. Skip
to step 2 of “Adjusting”.
Mounting location on single drive boat
Note 4: For twin drive boat, mount
between the drives.
Installation of bracket
1. Cut out the installation template shown
on the left.
2. At the selected location, position the
template, so the arrow at the bottom is
aligned with the bottom edge of the
transom. Being sure the template is
parallel to the waterline, tape it in place.
31
2°-10° transom angle (stepped
transom and jet boats): Position the
shim with the tapered end down.
19°-22° transom angle (small
aluminum and fiberglass boats):
Position the shim with the tapered end
up.
If you do not know the transom angle,
temporarily attach the bracket and
sensor to the transom to determine if
the plastic shim is needed.
5. Using the two #10 x 1-1/4” self-tapping
screws, temporarily screw the bracket to
the hull. DO NOT tighten the screws
completely at this time. Follow the step
1-4 in “Attaching the Sensor to the
Bracket”, before proceeding with
“Adjusting”.
3. If the bracket has been temporarily
fastened to the transom, remove it.
Apply a marine sealant to the threads of
the two #10 x 1-1/4” self tapping screws
to prevent water seeping into the
transom. Screw the bracket to the hull.
Do not tighten the screws completely at
this time.
4. Repeat step 1 to ensure that the angle
of the sensor is correct.
Adjusting
1. Using a straight edge, sight the
underside of the sensor relative to the
underside of the hull. The stern of the
sensor should be 1-3 mm (1/16-1/8”)
below the bow of the sensor or parallel
to the bottom of the hull.
Note: Do not position the sensor farther
into the water than necessary to avoid
increasing drag, spray, and water noise
and reducing boat speed.
2°-10° 11° transom angle 19°-22°
transom
NO SHIM
transom
angle
angle
shim with
shim with
taper up
taper down
YES
YES
parallel
parallel
12-18° transom angle
NO SHIM
NO
YES
5. Using the vertical adjustment space on
the bracket slots, slide the sensor up or
down to provide a projection of 3 mm
(1/8”). Tighten the screws.
YES
Cable cover
parallel
Cable
clamp
NO
50 mm (2")
angle
reversed
slight
angle
angle
too steep
Sensor position and transom angle
Hull projection 3 mm (1/8")
Vertical adjustment and cable routing
Note: Do not position the bow of the
sensor lower than the stern because
aeration will occur.
2. To adjust the sensor’s angle relative to
the hull, use the tapered plastic shim
provided. If the bracket has been
temporarily fastened to the transom,
remove it, Key the shim in place on the
back of the bracket.
32
1. If a hole must be drilled, choose a
location well above the waterline. Check
for obstructions such as trim tabs,
pumps, or wiring inside the hull. Mark
the location with a pencil. Drill a hole
through the transom using a 19 mm or
3/4” bit (to accommodate the
connector).
2. Route the cable over or through the
transom.
3. On the outside of the hull secure the
cable against the transom using the
cable clamps. Position a cable clamp 50
mm(2”) above the bracket and mark the
mounting hole with a pencil.
4. Position the second cable clamp
halfway between the first clamp and the
cable hole. Mark this mounting hole.
5. If a hole has been drilled in the transom,
open the appropriate slot in the transom
cable cover. Position the cover over the
cable where it enters the hull. Mark the
two mounting holes.
6. At each of the marked locations, use a 3
mm or 1/8” bit to drill a hole 10 mm
(3/8”) deep. The prevent drilling too
deeply, wrap masking tape around the
bit 10 mm (3/8”) from the point.
7. Apply marine sealant to the threads of
the #6 x 1/2” self-tapping screw to
prevent water from seeping into the
transom. If you have drilled a hole
through the transom, apply marine
sealant to the space around the cable
where it passes through the transom.
8. Position the two cable clamps and
fasten them in place. If used, push the
cable cover over the cable and screw it
in place.
9. Route the cable to the instrument being
careful not to tear the cable jacket when
passing it though the bulkhead(s) and
other parts of the boat. To reduce
electrical interference, separate the
sensor cable from other electrical wiring
and “noise” sources. Coil any excess
cable and secure it in place with zip-ties
to prevent damage.
Attaching the sensor to the bracket
1. If the retaining cover near the top of the
bracket is closed, open it by depressing
the latch and rotating the cover
downward.
Step 1
Step 2
Latch
Pivot
arm (2)
Retaining
cover
Slot (2)
Step 3
Step 4
Attaching the sensor to the bracket
2. Insert the sensor’s pivot arms into the
slots near the top of the bracket.
3. Maintain pressure until the pivot arms
click into place.
4. Rotate the sensor downward until the
bottom snaps into the bracket.
5. Close the retaining cover to prevent the
accidental release of the sensor when
the boat is underway.
Cable routing
Route the sensor cable over the transom,
through a drain hole, or thorough a new
hole drilled in the transom above the
waterline.
Never cut the cable or remote the
connector; this will void the warranty.
Always wear safety goggles and a dust
mask.
33
4.6 Optional Water
Temperature/Speed
Sensor
Locknut
Face "notch"
toward bow.
Water temperature/speed sensor
ST-02MSB and ST-02PSB, which are
designed for thru-hull mounting, are
optionally available. Install them as shown
below.
Flange Nut
51
123
Mounting considerations
Coat with
silicone sealant. Brim
Choose a suitable mounting location
considering the following:
φ77
• Choose a place free from vibration.
Water temperature/speed sensor
ST-02MSB, ST-02PSB
• Choose a mid-boat flat position. The
sensor does not have to be installed
perfectly perpendicular. The sensor must
not be damaged in dry-docking
operation.
4.7 Wiring
Refer to the interconnection diagram to
connect cables. Leave slack in cables to
facilitate checking and maintenance.
• Choose a place apart from equipment
generating heat.
• Choose a place in the forward direction
viewing from the drain hole, to allow for
circulation of cooling water.
Establishing the ground
The ground wire (1.25sq or more, local
supply) should be as short as possible. The
ground for the signal line is isolated from
the chassis, however the power line is not
insulated. Therefore, to connect external
equipment whose positive polarity is
connected to the ground line, do not
connect the signal line ground to chassis
ground.
1. Dry-dock the boat.
2. Make a hole of approx. 51 mm diameter
in the mounting location.
3. Unfasten locknut and remove the
sensor section.
4. Apply high-grade sealant to the flange
of the sensor.
5. Pass the sensor casing through the
hole.
6. Face the notch on the sensor toward
boat’s bow and tighten the flange.
7. Set the sensor section to the sensor
casing and tighten the locknut.
8. Launch the boat and check for water
leakage around the sensor.
The signal line ground is isolated from the
chassis ground, however the power line is
not insulated. Therefore, when connecting
external equipment having positive ground,
do not ground the signal line to the chassis.
If excessive noise shows on the screen, the
ground may be inadequate. In this case,
attach a steel plate measuring 20 cm by 30
cm on the outside of the hull to provide a
ground point. Connect the ground wire
) to
there. Use a “closed” type lug (
make the connection at the display unit. Do
34
not use an “open” type lug (
).
5. Use ▲ or ▼ to choose Off or On.
Choose On to output input data.
6. To restore normal operation, turn off the
power and then turn it on again.
Optional equipment
Pin arrangement on NMEA port
Connector
1
TD-A
2
TD-B
3
RD-A
4
RD-B
5
+Vout
6
GND
7
FG
Water temp/speed sensor
Remarks
Connect the optional water temp/speed
sensor to the XDR connector with the
optional converter connector (Type
02S4147) as shown below.
IEC-61162-1/NMEA0183
IEC-61162-1/NMEA0183
Connect to XDR port
at rear of display unit
Power output max. 100 mA*
MJ-A10SPF
* = The LS-6100 can feed 12 V power to
GP-310B, GP-320B. The power voltage must
be at least 12 V to feed power to those units.
MJ-A6SRMD
NMEA port setup
The NMEA port can function as an input
port or input/output port. Change the setting
to “In/In” when connecting GP-310B and a
wind sensor.
MJ-A10SRMD
Tape connectors with
vulcaninzing tape
and then vinyl tape
to waterproof them.
Bind tape ends with
cable ties to prevent
From tape from unraveling.
sensor
When connecting the GP-320B and a wind
sensor, first turn on “GPS WAAS” (in the
Installation menu) and then select “In/In” as
the NMEA port setting.
From
transducer
Connection of converter
connector 02S4147
1. Turn on the power while pressing and
holding down the [MENU/ESC] key.
Continue pressing the [MENU/ESC] key
until the Installation menu appears.
2. Choose NMEA PORT, and then press
► to display the NMEA port options
window.
3. Use ▲ or ▼ to choose In/Out or In/In as
appropriate.
GP-320B
DISPLAY UNIT
GPS Receiver GP-320B
® GPS Navigator GP-32,etc.
¬
In/Out: Input and Output (default
setting)
In/In: Input only (Available with
connection of the GP-310B and a wind
sensor.)
12 VDC
NMEA port setting: IN/OUT
Connection of GP-320B
4. Press ◄, choose NMEA MIX, and then
press ► to display the NMEA MIX
options window.
35
Input data sentences (con’t)
Wind sensor
Sentence
DISPLAY UNIT
¬
Wind Sensor
MWV
Wind speed and angle
RMA
Recommended
minimum specific
LORAN-C data
RMB
Recommended
minimum navigation
information
RMC
Recommended
minimum specific
GPS/TRANSIT data
VHW
Water speed and
heading
VTG
Course over ground
and ground speed
12 VDC
NMEA port setting: IN/OUT
Connection of wind sensor
Feeding data to RD-30 via the LS-6100
GP-310B
DISPLAY UNIT*
®
RD-30
¬
Output data sentences
12/24 VDC
Sentence
DBT (Ver. 1.5)
Wind Sensor
12 VDC
DPT (Ver. 2.0, Ver. 3.0)
MTW*
RMB* (Ver. 2.0)
NMEA port setting: IN/OUT
NMEA mix setting: ON
*: Navigator-related data not displayed.
VHW*
4.8 IEC 61162-1 Data
Sentences
TLL*
The tables below show the data sentences
which can be input to and output from the
LS-6100. The transmission speed for both
input and output is 4800 bps. Data is output
at two-second intervals.
Meaning
BWC
Bearing and distance to waypoint
GGA
Global positioning system (GPS)
fix data
GLL
Geographic position latitude/longitude
HDG
Heading, deviation and variation
HDT
Heading, true
MDA
Atmospheric pressure
MTW
Water temperature
Meaning
Depth below
transducer
Depth
Water temperature
Recommended
minimum navigation
information
Water speed and
heading
Target position, output
by [MARK] key.
* = Available with connection optional
sensors/navaid
Input data sentences
Sentence
Meaning
36
SPECIFICATIONS OF THE ECHO SOUNDER LS-6100
1. GENERAL
1.1 TX Frequency
50 kHz or 200 kHz, 50/200 kHz dual transmitting selectable
1.2 Transmit Method
Single or dual transmitting
1.3 Output Power
300 Wrms
1.4 TX Rate
Max. 550 pulse/min
1.5 Pulse-length
0.1 to 1.0 ms
1.6 Sensitivity
10 dBµV
2. DISPLAY UNIT
2.1 Display system
6-inch monochrome LCD, 92 mm (W) x 122 mm (H), 240 x 320 dots
2.2 Display Mode
Single frequency (high/low freq.), Dual-frequency, Zoom, Nav data-1/2
Marker zoom, Bottom zoom, Bottom-lock
2.3 Display Range
Range
Range Setting
1
Display
2
3
4
5
6
7
8
range
Meter
5
10
20
40
80
150
200
Feet
15
30
60
120
200
400
600 1000 7-1500
Fathoms
3
5
10
20
40
80
100
150 1-250
Passi/Braza
3
5
10
30
50
100
150
200 1-300
2.4 Range Shift
0-500 m, 0-1500 ft, 0-250 fa, 0-300 p/b
2.5 Expansion Range
Bottom-lock expansion: 3 to 10 m
300 2-500
Sectional expansion: 2 to 50 m
2.6 Display Advance Speed 8 steps (Lines/TX; Freeze, 1/16,1/8,1/4,1/2,1/1,2/1, 4/1)
2.7 Function Settings
Noise limit, Clutter, Signal level, Shift, A-scope, Deep gain
Automatic bottom tracking, White line, Hue, Advance speed
3. INTERFACE
3.1 Input data sentences
IEC61162-1/NMEA0183 Ver 1.5/2.0/3.0
GGA, RMA, RMB, RMC, BWC, GLL, HDT, HDG, VTG, VHW, MTW,
MWV, MDA, XTE
3.2 Output data sentences IEC61162-1/NMEA0183 Ver 1.5/2.0/3.0, interval: 2 s
MTW*, VHW*, DBT, DPT, RMB*, TLL* by key operating
*: External data required
4. POWER SUPPLY
12 VDC: 0.8 A
5. ENVIRONMENTAL CONDITIO N
5.1 Ambient Temperature
Display unit: -15°C to +55°C
5.2 Damp Heat
93% or less at 40°C
5.3 Water proofing
IPX5
6. COATING COLOR
N3.0
SP - 1
E2369S01E

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement