advertisement
The Digital Keyless Entry System (4 digit)
Operation User's Manual
DG-10
(Surface Mount)
DG-11
(Mount)
DG-12
(Mount/ANSI size)
ANSI Box
I. Features:
4 digit codes
Door Reed Switch Input for Anti-Trailing
10 user PINs
Fully Programmable via keypad and master code
Non-Volatile
Invalid PIN Lock-out
II. Specifications:
Operating Voltage: 9~14 Vdc
Current Draw: Average 30mA, Peak 80mA @ 12Vdc
Input: One request-to-exit, and time out reed switch
Relays: N.O./N.C./Com. Output (free voltage contact), 3A@ 125Vac or 30Vdc
Case Material: ABS (UL94V0)
Operating
Ambient Humidity:0~95% relative humidity non-condensing
Signals:
Green: Power on
Red: Relay activated
Yellow: Program Mode、Lock-out
Factory Master Code: 1234
Invalid PIN Lockout: System will shut down 60 seconds while 6 times of incorrectly password attempted.
Relay Activation Time: (*20)
Pulse
Latching
EPROM: Non-volatile memory, System will retain all programs and codes after a total loss of power.
User (* 01~*10)It is possible to program 10 different user PIN codes.
Copyright Gianni Industries, Inc. All Rights Reserved.
P-MU-DG10-4C Ver. A Publish:2004.09.07 Page: 1/ 2
III. Program Instruction:
Enter Program Mode:
1. Enter the master code twice (Factory master is 「1234」)
→2 beeps and the Yellow LED will light up.
→ you are now in the "programming mode".
2. Note: After 60 seconds if you have not entered any codes or data, the system will automatically exit from the programming mode. After 6 wrong attempts at the master code the lockout facility will operate.
Exiting from the program mode:
1. Press「#」 to exit from the programming mode.
2. Note: After 60 seconds if you have not entered any codes or data, the system will automatically exit from the programming mode. After 6 wrong attempts at the master code the lockout facility will operate.
To Enter a User Code:
Enter the Programming mode
1. Enter the slot position code 「*01~*10」 →????(user code 4 digit)→(beep)
→enrolled→ Press # to exit from the programming mode, or program other operating.
2. Note: The codes"0000","1234" or master code are not be used for PIN code.
To Program Relocking Timer(relay):
Enter the Programming mode
A. Press「*20」Followed by the number of seconds the relay should open→「05」
=5 seconds(01 ~99 = seconds)→(beep)→enrolled → Press 「#」 to exit from the programming mode, or program other operating.
B. Enter「00」Sets the relay to latching mode.
(Correct code entered opens the relay, and the relay stays open until the correct code is entered again).
To Delete a User Code:
Enter the Programming mode→ Press the slot position code of your choice to delete
(example "06") →Press「*06」→「0000」→(beep)→delete→Press「#」 to exit from the programming mode, or programming other operating.
To Change the Master codes:
Enter the Programming mode, Enter「*00」Followed by the new 5 digit master code→
( beep)→enrolled→Enter 「#」 to exit from the programming mode, or program other operating.
IV. Wiring diagram:
Note:
The varistor or diode must be connected across the lock terminal (electromagnet...) operated by the device. The vartistor controls the overload produced by the strike coil (EMP).
Copyright Gianni Industries, Inc. All Rights Reserved.
P-MU-DG10-4C Ver. A Publish:2004.09.07 Page: 2/ 2
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement