Graco 309640A is a RACX HandTite Guard designed to be hand tightened on a gun, eliminating the need for tools. It fits all Graco airless spray guns and is compatible with RACX series SwitchTips (sold separately). The patented aerodynamic design virtually eliminates paint buildup and is suitable for use at a maximum working pressure of 4050 psi (280 bar).
advertisement
Instructions
RACX HandTite t Guard
Model 246215, Series A, 7/8 in. Guard
4050 psi (280 bar) Maximum Working Pressure
Model 246437, Series A, 11/16 in. Guard
4050 psi (280 bar) Maximum Working Pressure
D Patented aerodynamic design virtually eliminates paint buildup.
D Hand tighten on gun–no tools required.
D Fits all Graco airless spray guns.
D Use with RACX series SwitchTips only.
D Graco RACX SwitchTip sold separately.
309640A
WARNING
To reduce the risk of fluid injection or splashing in the eyes or on the skin, relieve air and fluid pressure in the system before installing, cleaning or changing tips. See Pressure Relief Procedure in gun or sprayer manual.
S Keep clear of spray tip. High-pressure spray or leaks can inject fluid into the body, resulting in serious injury which may require amputation. Never spray without a tip guard (D).
S Do not exceed 4050 psi (280 bar, 28 MPa) maximum working pressure.
Failure to install or use the RAC t tip guard assembly correctly may result in an undirected spray of fluid into the eyes or on the skin of the operator.
Be sure you:
S Fully insert SwitchTip (A) into tip bore (C) in guard
S Do not trigger gun with SwitchTip handle between Spray and Clear positions
S Replace OneSealt when replacing worn SwitchTip
Installing Disassembling
A
1
D
2
B C
Use end of SwitchTip (A) to press OneSeal
(B) into tip guard (D), with curve matching tip bore (C)
1
Clear position
2 ti2508a
Insert SwitchTip in tip bore and firmly thread assembly onto gun
Use SwitchTip handle to remove OneSeal from tip guard
Clearing a Clogged SwitchTip
3
Spray position
4
Engage gun safety and rotate
SwitchTip handle to Clear position
Disengage gun safety and trigger gun into pail to clear SwitchTip
Engage gun safety and rotate
SwitchTip handle to Spray position
Disengage gun safety and trigger gun into pail to verify SwitchTip is clear
Note:If SwitchTip is still clogged, follow Pressure Relief Procedure in gun or sprayer manual, and remove SwitchTip for cleaning.
Graco Phone Number
TO PLACE AN ORDER, contact your Graco distributor, or call this number to identify the distributor closest to you: 1-800-690-2894 Toll Free
2 309641
GRACO INC.
P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441
ECOPYRIGHT 2002, GRACO INC.
Graco Inc. is registered to I.S. EN ISO 9001
Printed in USA 309641 October 2002
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project