Graco 312476B User's Manual

Add to my manuals
18 Pages

advertisement

Graco 312476B User's Manual | Manualzz

Instructions

Pole Gun with CleanShot

Shut-Off

Valve and Contractor

t

In-line Valve

312476B

-

For the application of architectural paints and coatings -

3600 psi (248 bar, 24.8 MPa) Maximum Working Pressure

Important Safety Instructions

Read all warnings and instructions in this manual. Save these instructions.

Model 289386, Series A (North America)

With 3--ft (0.9 m) extension (244163)

WARNING: HIGH PRESSURE.

Keep Clear of Nozzle

.

Read these instructions carefully.

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440- 1441

Copyright 2002, Graco Inc. is registered to I.S. EN ISO 9001 ti10698a

Symbols

Warning Symbol

WARNING

Caution Symbol

CAUTION

This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions.

This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.

The wallet-sized warning card provided with this pole gun should be kept with the operator at all times. The card contains important treatment information should a fluid injection injury occur. Additional cards are available at no charge from Graco Inc.

WARNING

SKIN INJECTION HAZARD

Spray from the spray tip, hose leaks or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Splashing fluid in the eyes or on the skin can also cause can also cause serious injury.

D

Fluid injected into the skin might look like just a cut, but it is a serious injury.

Get immediate surgical treatment.

D

Do not point the spray tip at anyone or any part of the body.

D

Do not put hand or fingers over the spray tip, and do not stop or deflect fluid leaks with your hand, body, glove or rag.

D

Do not “blow back” fluid; this is not an air spray system.

D

Always have the tip guard and the trigger guard on the in-line valve when spraying.

D

Be sure the trigger safety lever operates before operating the in-line valve.

D

Lock the trigger safety lever when you stop spraying.

D

Follow the

Pressure Relief Procedure

on page 4 when you are instructed to relieve pressure; stop spraying; check, clean, or service any system equipment; or install or change spray tips.

D

Tighten all fluid connections before each use.

D

Check the hoses, tubes and couplings daily. Replace worn or damaged parts immediately. Permanently coupled hoses cannot be repaired.

D

Handle and route hoses and tubes carefully. Keep hoses and tubes away from moving parts and hot surfaces. Do not use the hoses to pull equipment. Do not expose Graco hoses to temperatures above 150

_

F (65

_

C) or below --40

_

F (--40

_

C).

TOXIC FLUID HAZARD

Hazardous fluids or toxic fumes can cause a serious injury or death if the fluid is swallowed or splashed in the eyes or on the skin or if the fumes are inhaled.

D

Know the specific hazards of the fluid you are using.

D

Store hazardous fluid in an approved container. Dispose hazardous fluid according to all local, state and national guidelines.

D

Dress appropriately for your application. Wear protective eyewear, noise protection for the ears, a personal respirator, gloves, and clothing.

RECOIL HAZARD

Due to the high pressure fluid emitted, a strong recoil action may occur when you trigger the pole gun.

If you are unprepared, your hand could be forced back toward your body or you could lose your balance and fall, resulting in serious injury.

2 312476

WARNING

FIRE AND EXPLOSION HAZARD

Improper grounding, poor air ventilation, open flames, or sparks can cause a hazardous condition and result in fire or explosion and serious injury.

D

Ground the equipment and the object being sprayed. See

Electrical Grounding

on page 5.

D

Provide fresh air ventilation to avoid the buildup of flammable fumes from solvent or the fluid being sprayed.

D

Extinguish all the open flames or pilot lights in the spray area.

D

Electrically disconnect all the equipment in the spray area.

D

Keep the spray area free of debris, including solvent, rags, and gasoline.

D

Do not turn on or off any light switch in the spray area while operating or if fumes are present.

D

Do not smoke in the spray area.

D

Do not operate a gasoline engine in the spray area.

D

If there is any static sparking while using the equipment,

stop spraying immediately

. Identify and correct the problem.

EQUIPMENT MISUSE HAZARD

INSTRUCTIONS

Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and result in serious injury.

D

This equipment is for professional use only.

D

Read all instruction manuals, tags, and labels before operating the equipment.

D

Use the equipment only for its intended purpose. If you are uncertain about the usage, call your distributor.

D

Do not alter or modify this equipment. Use only genuine Graco parts and accessories.

D

Check the equipment daily. Repair or replace worn or damaged parts immediately.

D

Do not exceed the maximum working pressure of the lowest rated system component. This equipment has a

3600 psi (25 MPa, 248 bar) maximum working pressure.

D

Route the hoses away from the traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose Graco hoses to temperatures above 150

_

F (65

_

C) or below --40

_

F (--40

_

C).

D

Do not use the hoses to pull the equipment.

D

Use fluids or solvents that are compatible with the equipment wetted parts. See the

Technical

Data

section of all the equipment manuals. Read the fluid and solvent manufacturer’s warnings.

D

Fluid hoses must have spring guards on both ends to protect them from rupture caused by kinks or bends near the couplings.

D

Comply with all applicable local, state and national fire, electrical and other safety regulations.

D

Wear hearing protection when operating this equipment.

HAZARD OF USING FLUIDS CONTAINING HALOGENATED HYDROCARBONS

Never use 1,1,1-trichloroethane, methylene chloride, other halogenated hydrocarbon solvents or fluids containing such solvents in this equipment. Such use could result in a serious chemical reaction, with the possibility of explosion, which could cause death, serious injury and/or substantial property damage.

Consult your fluid suppliers to ensure that the fluids being used are compatible with aluminum and zinc parts.

312476 3

Installation

Installation

1. Connect grounded fluid hose to the Contractor

In--line valve.

2. Connect 3--ft extension to in--line valve. Use a wrench to tighten.

3. Connect the CleanShot Shut--off Valve. Use a wrench to tighten.

NOTE: Be sure seals (33 and 34) are in place in the in--line valve and shut--off valve before connecting the extension. Page 13.

4. Without the spray tip installed, start sprayer; turn the knob on the CleanShot Shut--Off Valve counter--clockwise to the flush position; flush and prime according to sprayer instructions.

NOTE:

The Contractor In--line valve can be used as an airless spray gun by attaching a HandTite t

Guard and RAC R IV Switch Tip.

4. Rotate the spray valve knob counter--clockwise to the out/flush position. Fig. 2.

5. Hold metal part of pole gun firmly to side of

grounded

metal waste container. Trigger in-line valve to relieve pressure.

6. Put in-line valve trigger safety lever in SAFETY

ON position. Fig. 1.

7. Open pump drain valve to help relieve fluid pressure in pump, hose, and pole gun. Triggering inline valve to relieve pressure may not be sufficient.

Have container ready to catch drainage.

8. Leave drain valve open until you are ready to spray again.

If you suspect that the spray tip or hose is completely clogged or that pressure has not been fully relieved after following the steps above, V

ERY SLOWLY loosen the tip guard retaining nut (Fig. 3) or hose end coupling and relieve pressure gradually, then loosen completely. Then clear tip or hose obstruction.

5.

Relieve the pressure following the

Pressure

Relief Procedure

below.

Pressure Relief Procedure

WARNING

INJECTION HAZARD

To reduce the risk of serious injury, including fluid injection, splashing in the eyes or on skin, or injury from moving parts, always follow this procedure when you stop spraying; check or service any part of spray system; or install, clean, or change the spray tip.

1. Put in-line valve trigger safety lever in SAFETY

ON position. Fig. 1.

2. Shut off power supply to pump. Open all air bleed valves in system.

3. Put in-line valve trigger safety lever in SAFETY

OFF position. Fig. 1.

9. Install spray tip.

Required Accessories

WARNING

INJECTION HAZARD

Your spray system must have a bleedtype master air valve and a fluid drain valve. They help reduce the risk of serious injury, including fluid injection, splashing in the eyes or on the skin, or injury from moving parts, if you are adjusting or repairing the pump or pole gun.

D

The

bleed-type master air valve

(air-powered pumps only) relieves air trapped between the valve and pump after the air regulator is shut off.

Trapped air can cause the pump to cycle unexpectedly.

D

The

fluid drain valve

assists in relieving fluid pressure in the displacement pump, hose and pole gun.

Triggering the in-line valve to relieve pressure may not be sufficient.

4 312476

Installation

Electrical Grounding

WARNING

FIRE AND EXPLOSION HAZARD

Improper grounding could cause static sparking, which could cause a fire or explosion. To reduce the risk of property damage or serious injury, follow the grounding instructions below.

D

Ground the

pump or sprayer

as instructed in its separate manual.

D

Ground the

air compressor or hydraulic power supply

according to the local electrical code and the manufacturer’s recommendations.

D

Use electrically conductive

fluid hoses

with a maximum combined hose length of 500 feet (150 m) to ensure grounding continuity.

D

Read and follow the warnings in

Fire and

Explosion Hazard

on page 3.

D

Provide electrical grounding continuity throughout the entire spray system as instructed below.

D

Ground the

pole gun

by connecting it to a properly grounded fluid hose and pump or sprayer.

D

Have a trained and qualified person perform all electrical wiring.

D

Comply with all applicable local, state, and national fire, electrical, and other regulations.

D

Ground the

fluid supply container

,

object being sprayed, all solvent pails used when flushing

according to the local electrical code

.

Use only metal pails, which are conductive. Do not place the pail on a non-conductive surface, such as paper or cardboard, which interrupts the grounding continuity.

The following grounding instructions are minimum requirements for a system. Your system may include other equipment or objects that must be grounded. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Your system must be connected to a true earth ground.

D

To maintain grounding continuity when flushing or relieving pressure

,

always hold a metal part of the pole gun firmly to the side of a

grounded

metal pail, then trigger the in-line valve.

312476 5

Operation

WARNING

INJECTION HAZARD

To reduce the risk of a fluid injection injury, do not operate the pole gun with the tip guard or trigger guard removed.

In-Line Gun Trigger Safety Lever

For SAFETY ON position, rotate trigger safety lever so it is in line with trigger. For SAFETY OFF position, flip safety lever so it is 90

_ to trigger. Fig. 1.

NOTE:

In the SAFETY ON position the lever sits in a detent which holds it in place.

Startup

1. Start pump. Adjust fluid pressure so spray is completely atomized. Always use lowest pressure that gets desired results. Higher pressure may not improve spray pattern and causes premature tip and pump wear.

NOTE:

The spray tip orifice size and spray angle determine the coverage and size of the pattern.

When more coverage is needed, use a larger spray tip rather than increasing the fluid pressure.

2.

If adjusting the pressure does not give a good spray pattern, try another size tip.

Relieve the pressure

before you change the spray tip.

3. Use full-open, full-close trigger action. Hold tip at a right angle to the work surface, about 14 inches

(350 mm) away. Do not swing pole gun in arcs.

Practice to find the best length and speed of stroke.

SAFETY ON SAFETY OFF

Fig. 1

Using the CleanShot Shut--Off Valve

The CleanShot Shut--Off Valve provides two settings:

SPRAY and FLUSH. The valve is factory set to the

SPRAY position for spraying at pressures above 700 psi (4.8 MPa, 48 bar). Rotate the valve knob counter-clockwise to the FLUSH position for flushing, cleaning, priming and relieving pressure. The FLUSH position is also used for low pressure spraying applications below

1000 psi (6.9 MPa, 69 bar). Fig. 2.

Fig. 2

6 312476

TI0687

Operation

Changing Spray Pattern Orientation

WARNING

To reduce the risk of a fluid injection injury, never spray without the tip guard.

Clearing a Clogged Spray Tip

Frequently during the job and at the end of each workday,

relieve the pressure

and manually clean the tip with a solvent-soaked brush. Frequent cleaning helps keep fluid buildup from drying and clogging the spray tip.

The orientation of the tip guard indicates the orientation of the spray pattern.

1. Put in-line gun trigger safety lever in SAFETY ON position. Fig. 1.

2. Turn the tip guard by hand to change the orientation. Fig. 3.

NOTE:

You may have to loosen the retaining nut to turn the tip guard by hand.

retaining nut tip guard

Fig. 3

Spraying a vertical band

CAUTION

ti10699a

Spraying a horizontal band

The openings in the tip guard are designed to reduce paint buildup on the guard while spraying.

Any damage to the sharp edges of the openings causes paint to collect at that area. To avoid damaging the tip guard, do not hang the pole gun by the tip guard.

ti10700a

Fig. 4

Use the Reversible Spray Tip to quickly clear clogs as follows:

1. Put in-line gun trigger safety lever in SAFETY ON position. Fig. 1.

2. Rotate arrow-shaped handle (Fig. 4) to UNCLOG position.

3. Put in-line valve trigger safety lever in SAFETY

OFF position, and trigger in-line valve into pail or onto ground to remove clog. Fig. 1.

4. Put in-line valve trigger safety lever in SAFETY

ON position (Fig. 1), and rotate arrow-shaped handle (Fig. 4) to SPRAY position.

If spray tip is still clogged, relieve the pressure by following the

Pressure Relief Procedure

on page 4 and manually clean it. To reduce tip clogs, strain the fluid you are spraying.

WARNING

INJECTION HAZARD

To reduce risk of an injection or splashing fluid in eyes or on skin, follow these precautions before you remove, clean, or change a spray tip or tip guard.

D

Do not hold your hand, body, or rag in front of spray tip when cleaning or checking clogged tip.

D

Always point tip toward ground or into waste container when checking to see if it is cleared.

D

Do not try to “blow back” paint; this is NOT an air spray system.

D

Follow

Pressure Relief Procedure

on page 4 before you wipe fluid buildup off spray tip, before you remove tip guard or spray tip, and whenever you are instructed to relieve the pressure.

312476 7

Operation

Flushing the CleanShot Shut--Off Valve

Rotate the spray valve knob counter--clockwise to the flush position (see

Using the CleanShot Shut--Off

Valve

on page 6), and follow the

Flushing the In-

Line Gun

procedure below.

Flushing the Contractor In-Line Gun

Always flush the in-line valve thoroughly when you stop spraying for the day and before the fluid being sprayed can dry or set up in the system.

3. If flushing with water, flush last with a rust inhibitor or Graco Pump Armor to protect the system from corrosion.

4. If necessary, disassemble pole gun and clean all passages thoroughly with a soft-bristled brush.

CAUTION

Do not soak the entire in-line valve in solvent.

Prolonged exposure to solvent can ruin the packings.

WARNING

FIRE AND EXPLOSION HAZARD

To reduce the risk of a serious injury from fluid injection, static sparking, or splashing fluid in the eyes on or the skin, follow these precautions when flushing:

D

Be sure entire system and flushing pails are properly grounded. See

Electrical Grounding

on page 5.

D

Remove spray tip.

D

Use lowest possible fluid pressure.

D

Maintain firm metal-to-metal contact between pole gun and pail during flushing.

D

Follow the

Pressure Relief Procedure

on page

4 whenever you are instructed to relieve pressure.

Checking the Gun Diffuser Operation

Check the diffuser operation weekly. The gun/diffuser/ seat (A) breaks up spray and reduces the risk of fluid injection when the tip is not installed. Perform the test below. If it fails, replace the entire Needle Kit, Part No.

218070. Diffuser/seats are not sold separately since the gun will leak if an old needle is used with a new diffuser/seat.

1. Follow

Pressure Relief Procedure

on page 4.

2. Remove the tip guard and spray tip.

3. Start the sprayer and adjust it to the lowest pressure.

4. Aim the gun into a grounded metal pail while holding it firmly to the pail. Trigger the gun. If the fluid emitted is not diffused into an irregular stream, replace the entire needle kit immediately.

A

1. Use a solvent that is compatible with wetted parts of pole gun, rest of system, and material being sprayed.

2. Follow flushing instructions for your spray system or pump.

Fig. 5

8 312476

Operation

Cleaning the Filter (Fig. 6)

Clean the filter assembly (5) daily, as follows:

1. Follow

Pressure Relief Procedure

on page 4.

2. Push up on the trigger guard (3) and swing it away from the trigger (2).

3. Unscrew the gun handle (13) from the housing

(11). Remove the filter and clean it in compatible solvent.

4. Apply lithium--base grease to the threads of the gun handle (13) and reassemble gun.

11

2

3

Fig. 6

13

5

312476 9

Service

Changing the Needle (Fig. 7)

NOTE: Needle (C), diffuser/seat (A), gasket (B) and locknut (D) must be replaced together. They are included in Repair Kit 218070.

2. Install bracket (10) and locknut (D) loosely on threaded end of needle (C). Squeeze trigger to pull needle assembly (C) into gun body (11). Tighten locknut (D) as required to install needle (C).

3. Squeeze trigger while installing gasket (B) and diffuser/seat (A). Torque diffuser/seat to 26--32 ft--lb (35--43 N

S m).

A B

C

11

10

D

4. If gun handle (13) was removed, hand tighten into fluid housing (11). It should fit easily.

Fig. 7

Disassembly

1. Follow

Pressure Relief Procedure

on page 4.

2. Remove tip guard assembly.

3. Squeeze trigger while unscrewing diffuser/seat (A) and gasket (B).

4. Remove locknut (D) and bracket (10).

5. Adjust needle before using gun.

6. Be sure trigger guard and tip guard are installed before using gun.

Adjusting the Needle (Fig. 7)

1. Engage gun safety latch.

2. Hold gun with nozzle straight up.

3. Remove trigger guard (3). (Fig. 6).

4. Hold your finger against trigger with light pressure.

Using a 5/16--in, open--ended wrench, turn locknut

(D) clockwise until you feel trigger depress slightly.

5. Turn adjusting nut 3/4 turn counter--clockwise.

5. Tap rear of gun with a plastic mallet to push needle assembly out front.

Reassembly

1. Guide threaded end of needle assembly into front of gun.

6. Connect fluid hose. Install tip guard and prime the system. Trigger gun and release it. The fluid flow should stop immediately. Engage safety latch and try to trigger gun.

No fluid should flow.

If the gun fails either test, relieve pressure, disconnect hose and readjust needle.

10 312476

Service

Replacing the Swivel (Fig. 8)

Disassembly

1. Follow

Pressure Relief Procedure

on page 4.

11

2. Push up on trigger guard (3) and rotate trigger guard away from trigger (2).

3. Unscrew gun handle (13) from housing (11).

Remove filter (5) and clean in compatible solvent.

4. Remove swivel (4), guard retainer (12) and cushion o--ring (14).

5. Save guard retainer (12) and cushion o--ring (14).

Reassembly

1. Clean internal thread of handle (13).

2. Install guard retainer (12), cushion o--ring (14) and swivel (4).

3. Apply PST pipe seal (included in Swivel Kit

238817) to external thread of swivel (4) that connects to handle (13).

4. Install swivel (4) into handle (13). Torque swivel to

250 in--lb.

5. Engage trigger guard (3) to retainer guard (12).

Fig. 8

3

12

14

4

2

13

5

312476 11

12 312476

Notes

Parts

Model 289385 CleanShot Shut--Off Valve

Model 244161 Contractor In--line Valve (North America)

Model 244364 Contractor In--line Valve (Europe)

Model 244365 Contractor In--line Valve (Asia)

32

40/41

3

30

(included in kit 221515)

33

34

33

34

31

35

1

8

19

10

2

7

13

14

12

4

11

6

20

5a

5b

5

5c

5d ti10697a

Page 14

312476 13

CleanShot Repair Kit 244162 (31)

Swivel Repair Kit 244363 (35)

Valve Body Repair Kit 245687 (36)*

Parts

31a Torque 26--32 ft-lb

31b

31c

31d

31e

35c

35d

35a

35b

Torque 55--60 in-lb

33

34

*36 Valve Body Kit must be purchased separately ti0947

36

31f

31g

31h

31i

31j

Torque 26--32 ft-lb

31k

31*

14 312476

Parts List

Model 289385 CleanShot Shut--Off Valve

Model 244161 Contractor In--line Valve (North America)

Model 244364 Contractor In--line Valve (Europe)

Model 244365 Contractor In--line Valve (Asia)

Ref.

No.

Part No. Description Qty.

3

4

1

2

218070 NEEDLE--DIFFUSER/SEAT KIT 1

244193 TRIGGER, gun, inline

196869 GUARD, trigger

238817 KIT, swivel 1

5 n

218131 FLUID FILTER ASSEMBLY

(standard 50 mesh) includes

1

1

1

6 n

179733 SEAL, sleeve

7

8

5a

5b

5c

5d

10

11 replacement parts 5a, 5b, 5c, 5d

179722 RETAINER, spring

179731 ELEMENT, strainer

179763 SPRING, compression

179750 RETAINER, spring

107110 LOCKNUT

197052 ADAPTER, RAC

197058 BRACKET, stem

197568 HOUSING, fluid, locking (North

America/Asia)

196828 HOUSING, fluid (Europe)

113409 RETAINER, guard

195788 HANDLE, gun (North America/

12

13

14

19

Europe)

243393 HANDLE, gun (Asia)

104938

177538

PACKING, o--ring

STUD, trigger

20 105334 NUT, lock, hex

21

Y

222385 WARNING CARD (not shown)

23

Y

187348 COVER, warning

1

1

1

2

1

1

2

1

1

1

1

1

1

1

1

1

Ref.

No.

Part No. Description Qty.

30

31

31a

31b

31c

31d

31e

31f

31g

31h

237859 RAC IV/5 Hand Tite Guard

7/8 in. (22 mm) thread

244162 KIT, CleanShot repair includes parts 31a--31k

SEAT, valve

GASKET

RETAINER, ball

DAMPENER, spring

SPRING, compression

GUIDE, spring

SEAL, u--cup

PACKING, o--ring

31i

31j

RETAINER, u--cup

CAP, end, u--cup

31k KNOB, valve

32 n

221515 TIP, spray, 515 0.015 in. (0.381mm)

1

1

1

1

1

1

1

1

1

1

1

33

34

35 orafice; 10--12 in. (254--304.8 mm) fan

162863 GASKET, non--metallic

120190 PACKING, o--ring

244363 KIT, swivel repair (includes

35a--35d)

SWIVEL, inlet assembly

NUT, cap

35a

35b

35c

35d

PACKING, o--ring

PACKING, o--ring

36 245687 KIT, Valve body

40

D

244163 3--FOOT POLE

41

D

244164 6--FOOT POLE

1

1

1

2

2

1

1

1

1

1

2

1

1

Y

Replacement Danger and Warning labels, tags and cards are available at no cost.

n

Keep these spare parts on hand to reduce down time.

D

Part number provided for reference only. Not available as a replacement part.

312476 15

Technical Data

Maximum fluid working pressure

Gun fluid inlet size

Gun fluid outlet size

CleanShot fluid orifice size

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3600 psi (25 MPa, 248 bar)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1/4 npsm

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Inline valve fluid valve orifice size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Wetted parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Maximum material temperature

Weight

Model 287023, 287026, 287028

7/8--14 unf

0.090 in. (3.175 mm) dia.

0.125 in. (2.286 mm) dia.

UHMWPE aluminum, tungsten carbide, stainless steel, PTFE, brass

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

120

_

F (50

_

C)

2.76 lb (1.03 kg)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.5 lb (1.3 kg) Model 287024, 287027, 287029

Sound data

*

Sound pressure level

Sound power level

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

78 dB(A)

87 dB(A)

* Measured while spraying waterbase paint -- specific gravity 1.36 through a 517 tip at 3,000 psi (21 MPa, 207 bar) per ISO 3744. Actual sound levels may vary with length of extension used.

16 312476

Notes

312476 17

Graco Standard Warranty

Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco,

Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non--Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of

Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT

NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS

The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.

TO PLACE AN ORDER

, contact your Graco distributor, or call this number to identify the distributor closest to you:

1--800--690--2894 Toll Free

All written and visual data contained in this document reflect the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

mm 312476

This manual contains English

Graco Headquarters:

Minneapolis

International Offices:

Belgium, Korea, China, Japan

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440--1441 www.graco.com

Revised 06/2009

18 312476

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project