Graham Field LUMISCOPE 1147 User's Manual

SIZE:72*97MM
SAFETY PRECAUTIONS
Advanced Wrist Blood Pressure Monitor
Model 1147
Instruction Manual
QUICK-START GUIDE
Babies, young children, or individuals who cannot express
their consent are not suitable for blood pressure
measurement.
Avoid smoking, eating or exercising for 30 minutes before
taking a measurement.
Individuals with serious arteriosclerosis are not suitable
for blood pressure measurement.
Measurement can be taken on either arm; however, if
possible, always take measurements on the left arm.
Blood pressure readings may fluctuate during pregnancy.
Pregnant women should consult their doctor before taking
measurement.
1. Sit upright in a chair with your
feet on the floor.
If there are unusual values, please consult your doctor
before taking medical action.
2. Remove tight-fitting or thick
clothing from the lower arm.
Handling batteries properly:
- As soon as old batteries wear out, replace them with new
batteries.
- Do not use old and new batteries together.
- Align the polarities of batteries correctly.
- When the unit will not be used for more than 3 months,
remove the batteries. Otherwise, batteries may leak and
cause damage to the unit.
Kpa
Read these instructions before using your Blood
Pressure Monitor. Save these instructions for
future reference.
2.1 Battery Installation
5. “ON” and “OFF” will then flash. This is to have the clock
display when the unit is not in use; you can choose
Clock Function “ON” or “OFF”. Press “ MEMO” or “PAGE ”
button to select. Press the “ AVG” button to confirm.
2. Insert 2 AAA batteries with the
polarities as indicated.
Note: If you select Clock Function “ON”, you will continue at
the Alarm Setting section. Otherwise, setting will end.
3. Slide the battery cover back to
close it. The cover will click into
place when completely closed.
2.3 Setting the Alarm
Note:Replace batteries when the battery indicator “
shows low voltage.
”
Note:
- You will not be able to set alarm clock if Clock Function
is set to “OFF”.
- You can set a maximum of 4 alarms.
2.2 Setting the Date and Time
Note:
- Set the correct date and time before taking a
measurement.
- Reset the date and time after replacing the batteries.
1. Press and hold the “ AVG” button for a few seconds until
the Year display flashes.
2. Press the“ MEMO” or “PAGE ” button to select the current
year.
3. Press the“ AVG” button to confirm Year Setting.
4. Follow the same steps to set the Month, Date, Hour and
Minute.
5
Systolic
User 1~ 4
Memory Average
Memory
Diastolic
Pulse Symbol
Power
(Start)
Memory Recall
(Up)
3. Pull on the end of the cuff until it wraps
securely around your wrist. Place your
arm on a table so that the cuff will be
at the same level as your heart.
Average Values
(Set)
4. Press the “ ” button. The cuff will automatically inflate and
the measurement will start.
5. When the measurement is
complete, the cuff will
automatically deflate and your
systolic and diastolic pressure
values and pulse rate will display.
9. When Minute digit flashes, press the“ MEMO” or “PAGE ”
button to select Minute. Press the“ AVG” button to
confirm.
10. Follow the same steps to set the 2nd, 3rd, and 4th Alarm.
Note:
- Press the “ ” button anytime during clock setting/alarm
setting to start over if an error occurs.
- Each alarm lasts 45 seconds, or you can turn it off by
pressing the “ ” button.
WHO Light
Indicator
Page Select
(Down)
Memory No.
(1-99 readings)
Features
•
•
•
•
•
•
One Touch Operation
Irregular Heartbeat Detector
Blood Pressure Mode and Clock Mode
4 User / 396 Total Memory
4 Alarm Clock Settings
5 Mode Averaging Function – Hour, Day, Week, Month,
and Overall
• WHO Blood Pressure Indicator with 6-Color LED
• Auto-off Power Saving Feature
• Operated by 2 AAA batteries
4
3.2 Applying the Wrist Cuff
1. Place your elbow on a table with the palm facing upward.
Wrap the wrist cuff around the left wrist as shown below.
2. Pull on the end of the cuff until it wraps securely around
your upper wrist. Do not over tighten the cuff. Allow 1-2
cm or ½ inch between the bottom of the cuff and your
wrist joint.
3. Make sure the cuff is at the same level as your heart.
TAKING A MEASUREMENT
Note:
- Avoid smoking, eating or exercising for 30 minutes before
taking a measurement.
- Do not move or talk during measurement.
- Measurement can be taken on either arm; however, if
possible, always take measurements on the left arm.
3.3 User Setting
This unit allows a maximum of 4 users to store measurement
records in different User Pages.
Press ”PAGE ” button to switch between User Page 1 ,2, 3 and 4.
3.4 Taking A Measurement
3.1 Sitting Correctly
6. To disable Alarm, Press the ” MEMO ” or “PAGE ” button
to select “OFF” and press the ” AVG” button to confirm.
7. To set 1st Alarm, Press the” MEMO” or ” PAGE ” button to
select “ON”. Press the ” AVG” button to confirm.
8. When Hour digit flashes, press the“ MEMO” or “PAGE ”
button to select Hour. Press the“ AVG” button to
confirm.
6
Date & Time
Low Battery
Indicator
3
PREPARATION
Monitor
Do not move or talk during measurement.
2
1147-INS-LAB-RevA09
1. Remove the battery cover in the
direction indicated on the cover.
OVERVIEW
1. Relax.
2. Sit upright in a chair with your feet on
the floor.
3. Remove thick or tight-fitting clothing
from the lower arm. Do not roll up
your sleeve if it is too tight.
4. Place your arm on a table so that the
cuff wil be at the same level as your
heart.
7
1. Press the “ ” button. The cuff will automatically inflate
and the measurement will start.
2. When the measurement is complete, the cuff will
automatically deflate and your systolic and diastolic
pressure values and pulse rate will display.
3. Remove the wrist cuff and take note of your measurement
results.
Note: You can press the “ ” button to stop measurement at
any time.
8
SIZE:72*97MM
3.5 Heartbeat Readings
WHO Classification
Color
Optimal -----------------------Blue
Normal ------------------------Sky Blue
High-normal -----------------Green
Mild hypertension ----------Purple
Moderate hypertension ---Yellow
Severe hypertension -------Red
Regular but Above Normal Heartbeat
Besides Systolic and Diastolic values,
Pulse will also be displayed after a
measurement
If the monitor detects a pulse rate above
100 beats per minute during measurement,
the monitor will display the pulse value and
“HI” symbol alternately. Example: (102/HI)
Pulse
Irregular Heartbeat
If an irregular rhythm occurs twice or more
during the same measurement, the monitor
will display the pulse value and “IH” symbol
alternately. Example: (90 / IH)
Note: Please consult your doctor if
irregular heartbeat occurs often.
Regular but Below Normal Heartbeat
3.6 WHO Light Indicator
This unit features a 6-color LED light indicator to display
blood pressure level in accordance with the WHO (World
Health Organization) classification.
mmHg
110
Grade 2 hypertension(moderate)
(Yellow)
105
100
If the monitor detects a pulse rate below
58 beats per minute during measurement,
the monitor will display the pulse value and
“LO” symbol alternately. Example: (58/LO)
Grade 1 hypertension(mild)
(Purple)
95
90
85
80
Normal
(Sky Blue)
Solution
No display when
you press the
Power/Start button Battery polarities
are incorrect
Replace with new batteries
“Err P” displays
Failure to inflate
Ensure the cuff is properly
connected
“Err 1” displays
Deflating too rapidly Return for service
Movement during Do not move during
measurement
measurement
Signal interference Remove interfering source,
e.g. mobile phones, magnets
“Err 3” displays
Incorrect results
mmHg
Remove the batteries from the unit when it will not be used
for more than 3 months.
SPECIFICATIONS
Measure again
STORAGE & MAINTENANCE
Keep away the unit from direct sunlight, extreme
temperatures, humidity or moisture.
Use a dry or slightly water-dampened cloth to clean the unit.
Do not use alcohol, benzene, thinner or other volatile liquids
to clean the unit.
Model No.
Measurement Method
Measurement Range
Inflation
1147
Oscillometric
Pressure: 20 – 280 mmHg
Pulse Rate: 40 – 195 beats/min
Pressure: +/- 3 mmHg
Pulse Rate: +/- 5%
Pump driven
Pressure Detection
Power Supply
Semi-conductor
2x AAA batteries
Auto Power Off
3 minutes after last operation
Accuracy
Storage Environment
-4°F to 140°F, 10% to 95% RH
Operation Environment 50°F to 104°F, 30% to 85% RH
External Dimensions
Net Weight
Cuff Dimensions
Package Contents
3. Press the “ MEMO” button to display the next sets of
values for the user selected. Past readings are
displayed from the most recent to the oldest.
4. This blood pressure monitor can store up to 99 sets of
past readings for each user (4 x 99).
11
Do not wash the wrist cuff or expose it to liquid.
Re-align batteries in correct
polarities
Note: If your problem cannot be solved by the above, consult
a GF Health Products, Inc. representative. DO NOT
disassemble the unit.
13
170 180
10
TROUBLESHOOTING
Possible Cause
160
Systolic Pressure
9
Batteries are worn
out
1. Press the “ MEMO” button to enter memory function.
2. If the User Page is not what you want to view, press the
“PAGE ” button to select.
Optimal(Blue)
140 150
MEMORY FUNCTIONS
4.1 View Past Readings
High- normal(Green)
120 130
Example: If your measurement reading is 122/75, the LED light
will display the color in blue.
After measurement, the last set of measured values will be
saved automatically after measurement when the unit is
turned off by pressing “ ” button or by automatic power-off
after 3 minutes.
Grade 3 hypertension(severe) (Red)
Diastolic Pressure
Note: An irregular heartbeat is defined as a
heartbeat rhythm that has a variation of
more than 25% from the average rhythm
detected during measurement.
“Err 2” displays
Kpa
WHO Light Indicator
This unit has a unique feature that alerts user of irregular
heartbeat detection during measurement.
Symptom
4.2 View Average Readings
3.15” (L) x 3.35”(W) x 2.36” (H) or
80 x 85 x 60 mm
140g (batteries excluded)
Wrist circumference of 135~220mm
Blood Pressure Monitor,
Instruction Manual, Batteries
Note: Specifications are subject to modification without
prior notice.
14
1. Press the “ AVG” button to enter Average function.
2. If the User Page is not what you want to view, press the
“PAGE ” button to select.
3. Press the “ AVG” button to view different Average Values.
5 different Average Values are available:
Symbol on Display
Average Values of
1 h
1 d
One Hour
One Day
7 d
30 d
One Week
One Month
ALL
All Readings
4.3 Delete Past Readings
User can delete all the past readings stored in each User
Page.
1. Press the “PAGE ” button to select the User Page you want
to delete.
2. Press and hold the “ MEMO” & “PAGE ” buttons
simultaneously for 5 seconds. Symbol of “ALL EE” will be
displayed and all past readings stored in that User Page
will be deleted.
12
LIFETIME LIMITED WARRANTY
GF Health Products, Inc. offers a lifetime limited warranty
on defects in material and workmanship for this product,
except as noted below:
This product warranty does not cover damage caused by
misuse or abuse, the attachment of any unauthorized
accessory, alteration to the product, or any other
conditions whatsoever that are beyond the control of
GF Health Products, Inc. GF Health Products, Inc. shall
not be responsible for any type of incidental,
consequential, or special damage.
To obtain warranty service on your Lumiscope
Blood Pressure Monitor, please contact the Repair
Department at 1-800-672-8293. There is a $15 fee for
return shipping and handling. Please make checks payable
to GF Health Products, Inc.
Upon receipt, we will repair or replace, as appropriate,
the Blood Pressure Monitor and return it to you. This
warranty does not include any labor charges incurred in
replacement part(s) installation or any associated freight
or shipping charges to GF Health Products, Inc.
Warranty is solely through the Repair Department.
Service of this product by anyone other than the Repair
Department voids warranty.
15
GF Health Products, Inc.
2935 Northeast Parkway
Atlanta, Georgia 30360
telephone: 800-347-5678, 770-447-1609
fax: 800-726-0601, 678-291-3232
www.grahamfield.com
© December 2009 GF Health Products, Inc.
Made in China