SPLIT TYPE ROOM AIR CONDITIONER

OPERATION MANUAL

HSU-09RC03/R2(DB)

HSU-12RC03/R2(DB)

HSU-18RC03/R2(DB)

HSU-22RC03/R2(DB)

Please read this operation manual before using the air conditioner.

Cautions operation and maintenance of the air

contains refrigerants, which require specialized waste disposal. The valuable materials The manufacturer does not accept respon-

.Contact your local waste disposal center for proper disposal of an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that

Damaged air conditioners are not to be the pipework of your air conditioner does not get damagedprior to being picked up by the your supplier.

relevant waste disposal center, and contribute to environmental awareness by insisting on an

Installation shall be done by professional people, don't install unit by yourself.

Disposal of the packaging of your new air conditioner

For the purpose of the safety,the air conditioner must be properly grounded in accordance with specifications.

All the packaging materials employed in the Always remember to unplug the air package of your new air conditioner may be conditioner before openning inlet grill. Never disposed without any danger to the unplug your air conditioner by pulling on environment.

the power cord. Always grip plug firmly and pull straight out from the outlet.

The cardboard box may be broken or cut into smaller pieces and given to a waste paper

All electrical repairs must be carried out disposal service. The wrapping bag made of by qualified electricians. Inadequate repairs polyethylene and the polyethylene foam pads may result in a major source of danger for contain no fluorochloric hydrocarbon.

the user of the air conditioner.

All these valuable materials may be taken to or performating the air conditioner's tubes adequate recycling.

with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings

Consult your local authorities for the name out and gets into eyes, it may result in centers and waste paper disposal services serious eye injuries.

nearest to your house.

1

Cautions or any other things into the inlet/outlet and swing louver.

7. The appliance is not intended for use

by young children or infirm persons

conditioner.In no case should children be allowed to sit on the outdoor unit.

8. Young children should be supervised

to ensure that they do not play with

the applience.

Specifications

9.Please employ the proper power plug,

which fit into the power supply cord.

The refrigerating circuit is leak-proof.

The machine is adaptive in following

situation

10 .The power plug and connecting cable

must have acquired the local attestation.

1.Applicable ambient temperature range:

Maximum:D.B/W.B

Indoor

Minimum:D.B/W.B

Cooling

Outdoor

Maximum:D.B/W.B

Maximum:D.B

Indoor

Maximum:D.B

Maximum:D.B

Heating Outdoor

Maximum:D.B/W.B

Minimum:D.B/W.B

Outdoor Maximum:D.B/W.B

(INVERTER) Minimum:D.B/W.B

32 o

C/23 o

C

18 o

C/14 o

C

43 o

C/26 o

C

18 o

C

27 o

C

15 o

C

24 o

C/18 o

C

-7 o

C/-8 o

C

24 o

C/18 o

C

-15 o

C

2. If the power supply cord is damaged, it

must be replaced by the manufacturer

or its service agent or a similar qualified

person.

3. If the fuse of indoor unit on PC board is

broken,please change it with the type of

T. 3.15A/ 250V. If the fuse of outdoor

unit is broken,change it with the type of

T.25A/250V

4. The wiring method should be in line with

the local wiring standard.

5. After installation, the power plug should

be easily reached.

2

Cautions

Safety Instruction

Please read the following Safety Instructions carefully prior to use.

The instructions are classified into two levels, WARNING and CAUTION according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use.

Installation

WARNING

Please call Sales/Service Shop for the Installation.

Do not attempt to install the air conditioner by yourself because improper works may cause electric shock, fire, water leakage.

lnstallation in a inadequate place may cause accidents. Do not install in the following place.

CAUTION

Connect the earth cable.

place where there is exposed to vapor any possibility of or oil steam.

inflammable gas

leakage around the

unit.

earthing

Check proper installation of the drainage securely

STRICT

ENFORCEMENT PROHIBITION PROHIBITION

3

Cautions

When abnormality such as burnt-small found,

immediately stop the operation button and contact sales shop.

WARNING

Use an exclusive power source with a circuit breaker

OFF

Connect power supply cord to the outlet completely

STRICT

ENFORCEMENT

Use the proper voltage

Do not use power supply cord

extended or connected in halfway

STRICT

ENFORCEMENT

Do not use power supply cord in a bundle.

STRICT

ENFORCEMENT

Take care not to damage the power supply cord.

PROHIBITION

Do not insert objects into the air inlet or outlet.

PROHIBITION

Do not start or stop the operation by disconnecting the power supply cord and so on.

PROHIBITION

PROHIBITION

Do not channel the air flow directly at people, especially at infants or the aged.

Do not try to repair or reconstruct by yourself.

PROHIBITION PROHIBITION food, art work, precise equipment, breeding, or cultivation.

same time.

CAUTION

PROHIBITION or other heating apparatus.

installation stand

STRICT

ENFORCEMENT PROHIBITION

Do not pour water onto the unit for cleaning

PROHIBITION

Do not place animals or plants in the direct path of the air flow

PROHIBITION

Do not place any objects on or climb on the unit.

PROHIBITION

Do not place flower vase or water containers on the top of the unit.

PROHIBITION PROHIBITION

4

PROHIBITION

Parts and Functions

Indoor unit

Display panel

Inlet grille

Air Purifying Filter

(inside)

Vertical louver

(Use remote controller to adjust up and down air flow.

Don't adjust it manually)

Horizontal louver

(adjust left and right air flow)

Outlet

Air filter(inside)

Anion generator

(inside)

Power plug

Outdoor unit

4

HSU-09RC03/R2(DB)

HSU-12RC03/R2(DB)

HSU-18RC03/R2(DB)

1 OUTLET

2 INLET

HSU-22RC03/R2(DB)

3 CONNECTING PIPING AND ELECTRICAL WIRING

4 DRAIN HOSE

5

Parts and Functions

31

1. HEALTH button

Used to set healthy operation.

2. HOUR button

Used to set clock and timer setting.

3. MODE button

Used to select operation mode. AUTO,

COOL,DRY, FAN,HEAT.

4. SLEEP button

Used to select sleep mode.

5. CLOCK button

Used to set correct time.

6. TIMER button

Used to select TIMER ON,

TIMER OFF, TIMER ON-OFF.

7. RESET

When the remote controller appears

abnormal, use a sharp pointed article

to press this button to reset the

remote controller normal.

8. HEALTH display

9. SLEEP display

10. SWING UP/DOWN display

?

11. LOCK display

12. FAN SPEED display

LOW MED HI AUTO

13. TIMER ON display

14. TEMP button

Used to select your desired temperature.

15. Operation mode display

Operation mode AUTO COOL DRY HEAT FAN

Remote controller

16. SINGAL SENDING display

17. POWER/SOFT display

18. Left/right air flow display

19. TEMP display

Remote controller: to display the TEMP. setting.

20. TIMER OFF display

21. CLOCK display

22. FAN button

Used to select fan speed: LOW,MED, HI, AUTO.

23. ON/OFF button

Used for unit start and stop.

24. SWING UP/DOWN button

Used to select up or down air sending direction.

25. SWING LEFT/RIGHT button

Used to select left or right air flow.

26. HEALTH AIRFLOW button

Used to set the health airflow mode.

27. SET button

Used to confirm timer and clock settings.

28. POWER/SOFT button

29. LOCK

Used to lock buttons and LCD display. If

pressed, the other buttons will be disabled

and the lock condition display appears.

Press it once again, lock will be canceled

and lock condition display disappears.

30. LIGHT button

Colorful display bar of the controlling indoor

machine is on and extinguished.

31. CODE

Used to select CODE A or B with a press,A or

B will be displayed on LCD.

Please select A without special explanation.

(2) Cooling only unit do not have functions and displays related with heating.

6

Parts and Functions

Clock Set

When unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows:

1. Press CLOCK button,"AM" or "PM" flashes.

2. Press or to set correct time. Each press will increase or decrease 1

min. If the button is kept depressed, time will change quickly.

3. After time setting is confirmed, press SET, "AM" or "PM" stop flashing,

while clock starts working.

Remote controller's operation

When in use, put the signal transmission head directly to the receiver hole on the indoor unit.

The distance between the signal transmission head and the receiver hole should be within 7 m without any obstacle as well.

Don't throw or knock the remoter controller.

When electronic-started type fluorescent lamp or change-over type fluorescent lamp or wireless telephone is installed in the room, the receiver is apt to be disturbed in receiving the signals, so the distance to the indoor unit should be shorter.

Loading of the battery

Load the batteries as illustrated right

2 R-03 (7#) batteries

Remove the battery cover:

Slightly press" "area and push down the cover as illustrated.

Load the battery:

Be sure that the loading is in line with the "+" / "- ".

request as illustrated on the bottom of the case.

Put on the cover again.

Confirmation indicator:

After pressing power ON/OFF, if no display, reload the batteries.

Note:

Full display or unclear display during operation indicates the batteries have been used up.

Please change batteries.

Used two new same-typed batteries when loading.

If the remote controller can't run normally during operation, please remove the batteries and

reload several minutes later.

Hint:

Remove the batteries in case unit won't be in usage for a long period. If there are any display after taking-out, just need to press reset key.

7

Operation

Health Operation

Remote controller

Display panel

1. Unit start

Link with electronic power.

Press ON/OFF on the remote controller, unit starts.

The liquid crystal will display the working state of last

time (Except Timer, Sleep, Power/Soft and Health

airflow).

Then set up the comfortable working state.

2. Select operation mode

Press HEALTH button. For each press, is displayed.

The pilot light of healthy process on the display board is on, hence healthy process begins.

When indoor fan motor is running, it has healthy process function. (It's available under any mode)

3. Unit stop

Press HEALTH button, the healthy function stops.

The pilot light of healthy process on the display board

is extinguished.

BRIEF INTRODUCTION TO HEALTH OPERATION

The anion generator in the air conditioner can generate a lot of anion to effectively balance the quantity of position and anion in the air and also to kill bacteria and speed up the dust sediment in the room and finally clean the air the room.

Note

When the fan in the indoor unit does not work, the health lamp lights up, but the anion generator does not release anion.

8

Operation

Auto Operation

Remote controller

Display panel

1. Unit start

Link with electronic power.

Press ON/OFF on the remote controller, unit starts.

The liquid crystal will display the working state of last

time (Except Timer, Sleep, Power/Soft and Health

airflow).

2.Select operation mode

Press MODE button. For each press, operation mode changes as follows:

Remote controller:

AUTO COOL

Then Select Auto operation

DRY FAN HEAT

3.Fan speed selection

Press FAN button. For each press, fan speed changes as follows:

Remote controller:

LOW MED AUTO

Air conditioner is running under displayed fan speed

When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.

4.Unit stop

Press ON/OFF button, the unit stops.

About Auto Operation

Under the mode of auto operation, air conditioner will automatically select Cool or Heat operation according to room temperature.

9

Operation

Cool Operation

Display panel

Remote controller

1. Unit start

Link with electronic power.

Press ON/OFF on the remote controller, unit starts.

The liquid crystal will display the working state of last

time (Except Timer, Sleep, Power/Soft and Health

airflow).

2.Select operation mode

Press MODE button. For each press, operation mode changes as follows:

Remote controller:

AUTO COOL DRY FAN HEAT

Then Select COOL operation

3.Select temp.setting

Press TEMP. button

Every time the button is pressed, temp.setting

increase 1 C,if kept depressed, it will increase rapidly

Every time the button is pressed, temp.setting

increase 1 C,if kept depressed, it will decrease rapidly

Select a desired temperature.

4.Fan speed selection

Press FAN button. For each press, fan speed changes as follows:

Remote controller:

LOW MED AUTO

Air conditioner is running under displayed fan speed

When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.

5.Unit stop

Press ON/OFF button, the unit stops.

10

Operation

Dry Operation

Display panel

Remote controller

1. Unit start

Link with electronic power.

Press ON/OFF on the remote controller, unit starts.

The liquid crystal will display the working state of last

time (Except Timer, Sleep, Power/Soft and Health

airflow).

2.Select operation mode

Press MODE button. For each press, operation mode changes as follows:

Remote controller:

AUTO COOL DRY FAN HEAT

Then Select DRY operation

3.Select temp.setting

Press TEMP. button

Every time the button is pressed, temp.setting

increase 1 C,if kept depressed, it will increase rapidly

Every time the button is pressed, temp.setting

increase 1 C,if kept depressed, it will decrease rapidly

Select a desired temperature.

4.Fan speed selection

Press FAN button. For each press, fan speed changes as follows:

Remote controller: emp C

On reaching temp.setting +2 o

C unit will run in mild DRY mode.

LOW MED AUTO

COOL operation starts when room temp.is higher than temp.setting.

Ultra-low air flow

Air conditioner is running under displayed fan speed

In DRY mode, when room temperature becomes 2 o

C higher than temp.setting,unit will run intermittently at

LOW speed regardless of FAN setting.

5.Unit stop

Press ON/OFF button, the unit stops.

11

Operation

Fan Operation

Display panel

Remote controller

1. Unit start

Link with electronic power.

Press ON/OFF on the remote controller, unit starts.

The liquid crystal will display the working state of last

time (Except Timer, Sleep, Power/Soft and Health

airflow).

2.Select operation mode

Press MODE button. For each press, operation mode changes as follows:

Remote controller:

AUTO COOL DRY FAN HEAT

Then Select FAN operation

3.Fan speed selection

Press FAN button. For each press, fan speed changes as follows:

Remote controller:

LOW MED

4.Unit stop

Press ON/OFF button, the unit stops.

About FAN operation

In FAN operation mode, the unit will not operate in

COOL or HEAT mode but only in FAN mode ,AUTO is not available in FAN mode.And temp.setting is disabled.

In FAN mode,SLEEP operation is not available.

12

Operation

Heat Operation

Display panel

Remote controller

1. Unit start

Link with electronic power.

Press ON/OFF on the remote controller, unit starts.

The liquid crystal will display the working state of last

time (Except Timer, Sleep, Power/Soft and Health

airflow).

2.Select operation mode

Press MODE button. For each press, operation mode changes as follows:

Remote controller:

AUTO COOL DRY FAN HEAT

Then Select HEAT operation

3.Select temp.setting

Press TEMP. button

Every time the button is pressed, temp.setting

increase 1 C,if kept depressed, it will increase rapidly

Every time the button is pressed, temp.setting

increase 1 C,if kept depressed, it will decrease rapidly

Select a desired temperature.

4.Fan speed selection

Press FAN button. For each press, fan speed changes as follows:

Remote controller:

LOW MED AUTO

Air conditioner is running under displayed fan speed

IN HEAT mode, warm air will blow out after a short period of the time due to cold-draft prevention function.

When FAN is set to AUTO, the air conditioner automatically adjusts the fan speed according to room temperature.

5.Unit stop

Press ON/OFF button, the unit stops.

13

Operation

Air Flow Direction Adjustment

1.Status display of air sending direction

Vertical flap

Pos.1

Pos.2

Pos.3

Pos.4

Pos.5

Pos.6

(Auto swing)

Horizontal louvers

Pos.1

Pos.2

Pos.3

Pos.4

Pos.5

Pos.6

Pos.7

Pos.8

2.Up and down air flow direction

For each press of button, air flow direction on remote controller displays as follows according to different operation modes:

COOL/DRY/FAN: remote controller: Pos.1

Pos.2

Pos.3

Pos.4

Pos.6

HEAT: remote controller: Pos.5

Pos.4

Pos.3

Pos.2

Pos.1

Pos.6

AUTO: remote controller: Pos.1

Pos.2

Pos.3

Pos.4

Pos.5

Pos.6

The vertical flap will swing according to the above positions

3.Left and right air flow direction

For each press of button, remote controller displays as follows : remote controller:

Pos.1

Pos.2

Pos.3

Pos.4

Pos.5

Pos.6

Pos.7

Pos.8

The horizontal louvers will swing according to the above positions.

Note:When restart after remote turning off, the remote controller will automatically

memorize the previous set swing position.

14

Operation

Display panel

Sleep Operation

Before going to bed, you can simply press the

SLEEP button and unit will operate in SLEEP mode and bring you a sound sleep.

Use of SLEEP function

After the unit starts, set the operation status, then press SLEEP button before which the clock must be adjusted and time being set.

Operation Mode

1. In COOL,DRY mode

1 hours after SLEEP mode starts, temp. will

become 1

O

C higher than temp. setting. After

another 1 hours, temp. rises by 1

O

C further.

The unit will run for further 6 hours then stops.

Temp. is higher than temp. setting so that room

temperature won't be too Iow for your sleep.

2.

Remote Controller

SLEEP operation starts

1 hr

1 hr p s

Rises 1

O

C

SLEEP operation stops

Rises 1

O

C

In COOL, DRY mode

Unit stop

In HEAT mode

1 hours after SLEEP mode starts, temp will become 2

O

C lower than temp.

setting. After another 1 hours, temp decrease by 2

O

C further. After more another 3 hours, temp. rises by 1

O

C further. The unit will run for further 3 hours then stops. Temp. is lower than temp. setting so that room temperature won't be too high for your sleep.

Unit stop

1 hr Decreases 2

O

C

1 hr

Decreases 2

O

C

3 hrs

3 hrs

Rises 1

O

C

SLEEP operation starts

In HEAT mode

SLEEP operation stops

3.

In AUTO mode

The unit operates in corresponding sleep mode adapted to the automatically selected operation mode.

4. In FAN mode

It has no SLEEP function.

Note

The sleeping hours lasts 8 hours and couldn't be adjusted.

When timing on function is set, the sleeping function can't be set up

After the sleeping function is set up, if user resets timing on function, the sleeping function will be cancelled; the machine will be in the state of timing-on. If the sleeping function and timing-on function are set up at the same time, no matter which one is operated earlier, the machine will be off automatically, and the other function will also be cancelled.

15

Operation

Timer On/Off Operation

Display panel

Remote Controller

Set clock correctly before starting TIMER operation.

1. After unit starts, select your desired operation mode

Operation mode will be displayed on LCD.

2. Timer mode selection

Press TIMER button to change TIMER mode. Every time

the button is pressed, display changes as follows:

Remote controller:

BLANK

TIMER ON TIMER OFF TIMER ON-OFF

Then select your desired TIMER mode (TIMER ON or

TIMER OFF). " "or " "will flash.

3.Time setting

Press HOUR button.

Every time the button is pressed, time setting

increases 1 min , if kept depressed, it will increase

rapidly.

Every time the button is pressed, time setting

decreases 1 min, if kept depressed, it will decrease

rapidly.

It can be adjusted within 24 hours.

4.Confirming your setting

After setting correct time, press SET button to confirm

" "or" "on the remote controller stops flashing.

Time displayed: Unit starts or stops at x hour x min.

(TIMER ON or TIMER OFF).

5.Cancel TIMER mode

Just press TIMER button several times until TIMER mode disappears.

Hints:

After replacing batteries or a power failure happens, time setting should be reset.

Remote controller possesses memory function, when use TIMER mode next time,just

press SET button after mode selecting if time setting is the same as previous one.

16

Operation

Timer On-Off Operation

Display panel

Remote Controller

Set clock correctly before starting TIMER operation.

1. After unit starts, select your desired operation mode

Operation mode will be displayed on LCD.

2. Timer mode selection

Press TIMER button to change TIMER mode. Every time

the button is pressed, display changes as follows:

Remote controller:

BLANK

TIMER ON TIMER OFF TIMER ON-OFF

Then select your desired TIMER mode (TIMER ON - OFF).

" " will flash.

3.Time setting

Press HOUR button.

Every time the button is pressed, time setting

increases 1 min , if kept depressed, it will increase rapidly.

Every time the button is pressed, time setting

decreases 1 min, if kept depressed, it will decrease rapidly.

It can be adjusted within 24 hours.

4.Timer confirming for TIMER ON

After setting correct time, press TIMER button to confirm

" " on the remote controller stops flashing.

" " starts flashing.

Time displayed: Unit starts or stops at x hour x min.

5.Time setting for TIMER OFF

Just press HOUR button ,follow the same procedure in

"Time setting for TIMER ON"

6.Time confirming for TIMER OFF

After time setting,press SET button to confirm.

" " on the remote controller stops blinking.

Time displayed:Unit stops at x hour x min.

To cancel TIMER mode

Just press TIMER button several times until TIMER mode disappears.

According to the Time setting sequence of TIMER ON or TIMER OFF, either Start-Stop or Stop-Start can be achieved.

17

Operation

POWER/SOFT Operation

POWER Operation

When you need rapid heating or cooling, you can use this function.

Selecting of POWER operation

Press POWER/SOFT button. Every time the button is pressed,display changes as follows:

BLANK

POWER SOFT

Stop the display at

In POWER operation status:

In HEAT or COOL mode, fan speed automatically runs in HI mode for 15 min then returns to original status setting.

To cancel POWER operation

Press POWER/SOFT button twice ,POWER/SOFT disappears.

SOFT Operation

You can use this function when silence is needed for rest or reading.

Selecting of SOFT operation

Press POWER/SOFT button. Every time the button is pressed,display changes as follows:

BLANK

POWER SOFT

Stop the display at

In SOFT operation mode, fan speed automatically takes"LOW"

To cancel POWER operation

Press POWER/SOFT button twice ,POWER/SOFT disappears.

Hints:

During POWER operation, in rapid HEAT or COOL mode, the room will show inhomogeneous temperature distribution.

Long period SOFT operation will cause effect of not too cool or not too warm.

18

Operation

Health airflow Operation

1.Press ON/OFF to starting

The liquid crystal will display the working state of last time

(Except timer, sleeping, power/soft and health airflow).

Setting the comfort work conditions.

2.The setting of health airflow function

1).Press the button of health airflow, appears on the display. The nether inlet and outlet grills of the air conditioner are closed and the airflow is blown horizontally from the above inlet and outlet grills. Avoid the strong airflow blows direct to the body.

2).Press the button of health airflow again, appears on the display. The above inlet and outlet grills of the air conditioner are closed and the airflow is blown vertically from the nether inlet and outlet grills. Avoid the strong airflow blows direct to the body.

3.The cancel of the health airflow function

Press the button of health airflow again, both the inlet and outlet grills of the air conditioner are opened, and the unit goes on working under the condition before the setting of health airflow function.

After stopping, the outlet grille will close automatically.

Notice: Cannot pull direct the outlet grille by hand. Otherwise, the grille will run incorrectly. If the grille is not run correctly, stop for a minute and then start, adjusting by remote controller.

Note:

1 .After setting the health airflow function, the position of inlet and outlet grills is fixed.

2.In heating, it is better to select the mode.

3.In cooling, it is better to select the mode.

4.In cooling and dry, using the air conditioner for a long time under the high air humidity, a phenomenon falling drips of water occurs at the outlet grille .

5.Select the appropriate fan direction according to the actual conditions.

19

Operation

Emergency and Test Operation

Emergency operation:

Use this operation only when the remote controller

is defective or lost.

Pi

When the emergency operation switch is pressed,the" Pi "sound is heard once, which means the start of this operation.

In this operation, the system automatically selects the operation modes, cooling or heating, according to the room temperature.

When machine is running in emergency, the set value of temperature and wind speed couldn't be altered; meanwhile, it can't operate for dehumidifying or under timing mode.

Test operation:

Test operation switch is the same as emergency switch.

Pi...Pi

Use this switch in the test operation when the room temperature is below 16

O

C, do not use it in the normal operation.

Continue to press the test operation switch for more

than 5 seconds. After you hear the "Pi" sound twice,

release your finger from the switch: the cooling operation

starts with the air flow speed "Hi".

Removal of the restriction of emergency or test operation

Press the emergency operation switch once more, or manipulate through the

remote controller; the "Pi" sound, the emergency or test operation is terminated.

When the remote controller is manipulated, it gets the system back to the

normal operation mode.

20

Maintenance

For Smart Use of The Air Conditioner

Setting of proper room temperature

Do not block the air inlet or outlet

Proper temperature

Close doors and windows during operation

Use the timer effectively

During cooling operation, prevent the penetration of direct sunlight with curtain or blind.

for a long time, turn off the power supply main switch.

OFF

21

Maintenance

For Smart Use of The Air Conditioner

WARNING

Before maintenance,be sure to turn off the system and the circuit breaker.

Remote Controller Indoor Body

Wipe the air conditioner by using a soft and dry cloth.For serious stains,use a neutral

Do not use water, wipe the controller with a dry cloth.Do not use glass cleaner or chemical out of the cloth before wiping.then wipe off cloth.

detergent diluted with water.Wring the water the detergent completely.

Do not use the following for cleaning

Gasoline,benzine, thinner or cleanser may damage the coating of the unit.

Hot water over 40

O

C(104

O

F) may cause discoloring or deformation.

Air Filter cleaning

Open the inlet grille by pulling it upward.

Remove the filter.

Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward.

Clean the filter.

Use a vacuum cleaner to remove dust, or wash the filter with water.After washing, dry the filter completely in the shade.

Attach the filter.

Attach the filter correctly so that the "FRONT" indication is facing to the front.Make sure that the filter is completely fixed behind the stopper.If the right and left filters are not attached correctly, that may cause defects.

Close the inlet grille.

Once every two weeks

22

Maintenance

Replacement of Air Purifying Filter

1.Open the lnlet Grille

Open the inlet grille by pushing each ends of the inlet grille upward.(use thumbs to push up)

2.Detach the standard air filter

Slide the knob slightly upward to release the filter, then withdraw it.

3.Detach old Air Purifying Filter

Detach old Air Purifying Filter

4.Attach old Air Purifying Filter

Put air purifying filter appliances into the right and left filter frames .

The green aspect of the bacteria-killing medium air purifying filter will face outside, the white aspect will face to the machine.

5.Attach the standard air filter

(Necessary installation)

6.Close the Inlet Grille

Close the Grille surely

NOTE:

The air purifying filter of the bacteria-killing medium and the the multi-lights touching intermediary accessories with machine will be used based on real situation.

The bacteria-killing medium air purifying filter is available for a long time and needn't to be changed. But it must be noticed to use the vacuum cleaner frequently to adsorb the dusts covering the purifying filter lest the covering dusts effect the function of the bacteria-killing medium air purifying filter. (It is strictly prohibited for the bacteria-killing medium air purifying filter to be washed)

The air purifying filter of the multi-lights touching intermediary will be solarized in fixed time.

In normal family,it will be solarized every 6 months. The solarization time will last no less than 8 hours under the state of abundant sun.

23

Maintenance

To Keep Your Air conditioner in Good Condition after Season.

Operate in cooling mode for 2-3 hours.

To prevent breeding mold or bad smell, be sure to operate at the designated temperature or 30

O

C,cooling mode and High speed fan mode for 2-3 hours.

Put off the power supply cord.

Cleaning the body.

Take out the batteries from the wireless remote controller.

24

Maintenance

Before Setting in High season

Cleaning the standard air filter.

Operation without filter may cause troubles.Be sure to attach both right and left filters prior to the operation.

Each of them are of different shapes.

Connecting the cable.

Caution

Incomplete earthing may cause an electric shock.

EARTHING

Do not block the air inlet or outlet.

Plug-in

Caution

After brush away dust at the plug, insert the plug of the power supply cord into the outlet completely.In case of suing exclusive circuit breaker,switch on the circuit breaker.

NO WET HAND

25

Trouble shooting

Before asking for service, check the following first.

Normal

Performance inspection

Phenomenon

The system does not restart immediately.

Noise is heard:

Cause or check points

When unit is stopped, it won't restart immediately until 3 minutes have elapsed to protect the system.

When the electric plug is pulled out and reinserted, the protection circuit will work for 3 minutes to protect the air conditioner.

During unit operation or at stop, a swishing or gurgling noise may be heard. At first 2-3 minutes after unit start, this noise is more noticeable. (This noise is generated by refrigerant flowing in the system.)

During unit operation, a cracking noise may be heard. This noise is generated by the casing expanding or shrinking because of temperature changes.

Should there be a big noise from air flow in unit operation, air filter may be too dirty.

Smells are generated.

This is because the system circulates smells from the interior air such as the smell of furniture, cigarettes.

Mist or steam are blown out.

During COOL or DRY operation, indoor unit may blow out mist. This is due to the sudden cooling of indoor air.

Multiple check

Does not work at all.

Poor cooling

Is power plug inserted?

Is there a power failure?

Is fuse blown out?

Is the air filter dirty? Normally it should be cleaned every 15 days.

Are there any obstacles before inlet and outlet?

Is temperature set correctly?

Are there some doors or windows left open?

Is there any direct sunlight through the window during the cooling operation?(Use curtain)

Are there too much heat sources or too many people in the room during cooling operation?