This document describes how to build, setup, and use the driver and user space application necessary for using the ACP (Mwave) Modem in the IBM Thinkpad" 600, 600E, and 770 models which include the on board ACP modem hardware. The latest version of this document can always be found at http://www.ibm.com/linux/ltc/
Linux ACP Modem (Mwave) mini−HOWTO
Table of Contents
i
1. General Information and Hardware
Requirements
1.1. Introduction
The ACP Modem for Linux is a software based modem. Support software for the ACP modem is composed of a loadable kernel module and a user level application. Together these components support direct connection to public switched telephone networks (PSTNs) and support selected countries world wide. Refer to
Section 6 of this document for the supported country list.
The modem also supports the standard communications port interface (ttySx) and is compatible with the
Hayes AT Command Set.
ACP Modem software is continually under development. If you encounter bugs or usability issues, please contact us and we'll work to correct them.
1.2. Credits
This Linux ACP Modem driver was ported from the Windows NT" version of the driver available from IBM.
Many thanks to Keith Frechette, Charles Ball, and Frank Novak for their technical and support efforts in making this project possible.
1.3. Where Can I Get the Latest Version of this Driver?
The latest version of this driver is available from http://www.ibm.com/linux/ltc/
1.4. Are There Any Other Resources?
Thomas Hood's Debian GNU/Linux on IBM ThinkPad 600 and 600x page contains lots of useful information.
1.5. Copyright Notice and Disclaimer
Copyright (c) 2002 IBM Corporation
This document may be reproduced or distributed in any form without prior permission. Modified versions of this document may be freely distributed, provided that they are clearly identified as such, and this copyright is included intact.
This document is provided "AS IS", with no express or implied warranties. Use the information in this document at your own risk.
1. General Information and Hardware Requirements 1
Linux ACP Modem (Mwave) mini−HOWTO
1.6. Which Systems are Supported
This version of the ACP Modem driver supports the IBM Thinkpad" 600E, 600, and 770 that include on−board ACP modem hardware.
1.7. Features of the Modem
The ACP Modem provides the following features:
•
Standard asynchronous COM port interface (NS16550A UART compatible) operation
•
Bell−103/212A, CCITT−V.21/V.22,V.22bis protocols with data from 300 to 2400 bps
•
CCITT−V.32 protocols with data rates of 4800, 9600 uncoded, and 9600 bps Trellis coded (Optional)
•
CCITT−V.32bis protocols with data rates of 4800, 9600, 12000, and 14400 bps (optional)
•
ITU−T V.34 protocols with data rates from 2400 to 33600 bps.
•
56K capable modem
•
Hayes AT Command Set compatibility
•
DTMF and pulse dialing
•
Asynchronous error recovery protocol
•
Error correction via Microcom Network Protocol (MNP) classes 1−4
•
Error correction via the V.42 error correction standard
•
MNP class 5 for up to 2x data compression
•
V.42bis for up to 4x data compression
•
"Adaptive Rate Negotiation" which provides for "Fallback / Fallforward" as line quality deteriorates or improves
Your modem contains 56K technology. To take advantage of this technology, you must first make sure that your Internet Service Provider (ISP) supports a 56K modem protocol. Significantly higher modem connection speeds, up to 56kbps, require all−digital transmission connections from your ISP to the line card in the central office from which your phone line is connected. The actual connection rate may be limited by the quality of your telephone lines. Telephone line quality may vary from location to location. Current regulations limit maximum trasfer rates to 53K. While your modem contains 56K technology, typical maximum connection rates in the receive direction may be significantly less than 56K. Currently, 56K capability is for the receive direction only. The transmit direction uses V.34 technology.
1.6. Which Systems are Supported 2
2. Compilation, Installation, and Startup
2.1. Prerequisites
•
A 2.2.16 series (or later) Linux kernel source tree
•
An appropriate set of module utilities
• gcc version 2.7.x or later
If you are building the ACP Modem driver along with the user space application, you need to have a complete Linux source tree for your kernel, not just an up−to−date kernel image.
2.2. Building and Installing Source
1. Use tar xzvf mwavem−yyyymmdd.tar.gz
to unpack the distribution.
2. Change directories with cd mwavem−yyyymmdd
3. Use the ./configure command to configure the build options. Issue ./configure −−help to view all of the options. The defaults are probably okay though.
NOTE
As of mwavem−1.0.3 you must give ./configure the
−−enable−mwavedd argument in order to build the driver with the user space application.
4. Use the make command to build all of the ACP Modem binaries.
NOTE
Your gcc package should be at least at the 2.7.x level. Check your
/usr/src/linux/Documentation/Changes file for the minimum version information.
5. Use make install to install the mwavem binary, mwavem.conf
configuration, the extra binary
(mostly .dsp) files, and module device driver (if you specified that it must be built) and to create the
/dev/modems/mwave device node.
2.3. Setting Things Up
In the [WORLDTRADE] section of your mwavem.conf
file, set the Country= parameter to your country access code.
NOTE
The mwavem.conf
file is installed in the
/usr/local/etc directory unless you specified otherwise during the build process
2. Compilation, Installation, and Startup 3
Linux ACP Modem (Mwave) mini−HOWTO
Country information (including access codes) are listed in the mwavem.conf
file. For example, for France the following section is present:
[Telephony\Country List\33]
CountryCode=00000021
Name=France
SameAreaRule=0FG
LongDistanceRule=0FG
InternationsalRule=00EFG
To set France to be your configured country in the [WORLDTRADE] section of mwavem.conf
, set Country=33
2.4. Runtime
An initialization script has been provided which may be used to to start, stop, or check the status of the ACP
Modem driver and application. It has been successfully run on the Debian, Slackware, SuSE, and Red Hat distributions and should run on any of their derivitives. If you are using the runtime script, it will load the mwave device driver module, configure the serial port, and start the mwave manager for you. All of the options which can be passed to the device driver module, along with some options for the script itself, can be configured by uncommenting and editing the appropriate variables at the beginning of the script.
The mwaved startup script can be found in the src/mwavem directory of the source distribution. If you are running the Red Hat distribution, you can copy the script to your /etc/rc.d/init.d
directory and issue the ntsysv command in order to enable it at boot time. If not using Red Hat, see the documentation for your distribution for information on how to set this up to run at boot time.
It is recommended that you use the provided mwaved script. If you are not using the script, however, the following sections will describe how to manually start the device driver and application.
2.4.1. Loading the ACP device driver
To load the mwave device driver use insmod mwave or modprobe mwave
The following arguments may be supplied with the insmod command:
NOTE
2.4. Runtime 4
Linux ACP Modem (Mwave) mini−HOWTO
The following arguments are not persistent from boot to boot (i.e. We are not saving them in the BIOS).
• mwave_3780i_irq=5/7/10/11/15
This parameter allows you to configure the IRQ used by the DSP if the DSP IRQ was not set and stored in BIOS by the Thinkpad" configuration utility.
• mwave_3780i_io=0x130/0x350/0x0070/0xDB0
This parameter allows you to configure the I/O range used by the DSP if the DSP I/O range was not set and stored in the BIOS by the Thinkpad" configuration utility.
• mwave_uart_irq=3/4
This parameter allows you to configure the IRQ used by the ACP UART if the Mwave's UART IRQ was not set and stored in BIOS by the Thinkpad" configuration utility.
• mwave_uart_io=0x3f8/0x2f8/0x3E8/0x2E8
This parameter allows you to configure the I/O range used by the ACP UART if the UART I/O range was not set and stored in BIOS by the Thinkpad" configuration utility.
The following code is an example of how to run DSP using ttyS1 resources: insmod mwave mwave_3780i_irq=10 mwave_3780i_io=0x0130 mwave_uart_irq=3 mwave_uart_io=0x2f8
NOTE
The mwave is unable to check for resource conflicts. It is your responsibility to ensure that none of the resources specified conflict with other (commonly PCMCIA) devices.
You can use the tpctl package on Linux or the Thinkpad" configuration utility on Windows NT or DOS to manage the configuration of Thinkpad" related resources.
2.4.2. Running ACP Modem Application
1. Once the ACP device driver is loaded successfully, use the mwavem command to execute the application.
NOTE
The location of the mwavem.conf
file can be specified as an argument to the mwavem application. If not specified the default location is assumed to be
/usr/local/etc/mwavem.conf
unless otherwise changed
2.4.2. Running ACP Modem Application 5
Linux ACP Modem (Mwave) mini−HOWTO during the build process.
2. Setup the serial driver to recognize the UART provided by the ACP driver. setserial /dev/ttyS0 autoconfig
NOTE
Substitute /dev/ttyS0 to match the serial port you have configured the DSP to use.
NOTE
You may wish to create a symbolic link from your modem device to your serial device for convenience. Example: ln −s /dev/ttyS0
/dev/modem
The ACP Modem is now available for use by your favorite dialing application.
2.4.2. Running ACP Modem Application 6
3. Resolving Installation and Configuration
Problems
The following sections list solutions to possible problems you may experience.
3.1. DSP Does Not Start
In order to recognize memory above 64 Meg, it may be necessary to append the "mem=" option to the kernel command line. If you are using LILO for your boot loader, you would do this in the lilo.conf
file. For example, if you had a machine with 128 Meg you would type: append="mem=130496K"
NOTE
Your statement must reflect 576K less than you actually have. Specifying the full amount of memory will prevent the DSP from starting. In the above example, the formula used to arrive at the proper number was 1024 * nMB −
576 = nK.
If you forget to run the Thinkpad" utility to enable the ACP Modem and you didn't specify any command line arguments when inserting the mwave module (or it didn't work), you will receive a message in the syslog, similar to the one below:
ACP Modem, UART settings IRQ 0x3 IO 0x2f8 tp3780::EnableDSP, pSettings−>bDSPEnabled 0 failed
Mwave Modem, ERROR cannot Enable DSP error fffffffb
Mwave Modem, ERROR cannot perform Mwave Initialization retval fffffffb
If you receive a message like the one above, check the command line arguments you provided to insmod.
3.2. Resource Conflicts
The ACP Modem requires the use of system resources for both the DSP and the UART provided by the ACP chip. For Linux systems, you will specify parameters to use for the duration of the boot with the insmod
mwave command line parameters listed in Section 2.4.1
Typically the configured resources are:
For the DSP: IRQ 10, I/O address 0x130−0x13f
For the UART: IRQ 3, I/O address 0x2f8 (if using ttyS1)
3. Resolving Installation and Configuration Problems 7
Linux ACP Modem (Mwave) mini−HOWTO
IRQ 4, I/O address 0x3f8 (if using ttyS0)
For dual boot systems we recommeded that you use the Thinkpad" Configuration Utility on Windows NT or
DOS to configure these system resources.
Windows NT Thinkpad Configuration Utility Notes: (Under the Internal Modem −−> Advanced selection)
1. Set IRQ sharing to disabled
2. Set 1st IRQ to your DSP IRQ (10 is recommened)
3. Set 2nd IRQ to your UART IRQ (i.e. ttyS1 is equivalent to COM2)
4. Set the DSP I/O address (0x130 is recommended)
5. Set the internal modem I/O address to the UART I/O address (i.e. 0x2f8 for COM2)
6. The DMA address is unused and can be set to anything.
NOTE
You may also specify parameters to use for the duration of the boot by using the insmod mwave line parameters
listed in section Section 2.4.1
3.3. Not Connecting at Specified Starting Speed
The configured initial connection speed is set to 64000. The modem should start there and negotiate down to a connection speed based on target modem and line capabilities. If the modem is unable to connect it may be having difficulty negotiating with the target modem. Try setting the SPEED parameter in mwavem.conf
to a lower initial starting speed. Supported speeds include:
•
64000
•
33600
•
14400
•
9600
•
2400
3.4. Dialer Application Cannot Detect Serial Port
The startup script that executes the serial port setup works well with Red Hat, Debian, Slackware, and SuSE.
If you are not running one of these distributions, you may need to perform the following steps in order to set up.
After inserting the mwave.o module and starting the mwavem application, you must run the
setserial command in order for the serial port configuration to discover the UART on the mwave hardware: setserial /dev/ttySx autoconfig
Replace ttySx with the serial port you have configured the ACP driver to use.
To test whether the serial port is setup correctly, run:
3.3. Not Connecting at Specified Starting Speed 8
Linux ACP Modem (Mwave) mini−HOWTO setserial /dev/ttySx
The above command should return the following for serial port 1:
/dev/ttyS1, UART: 16550A, Port: 0x2f8, IRQ: 3
The port and IRQ numbers should match the information placed in the syslog by the ACP module when it was loaded: kernel: Mwave Modem, UART settings IRQ 0x3 IO 0x2f8
If the information returned by setserial indicates that the UART is 'unknown' or if the IRQ and I/O resources do not match what you have in the syslog, you will need to reconfigure. Check the setserial man pages to learn how to setup the resources on your ttySx to match what appears in the syslog output.
If you have problems running setserial, you may have a resource conflict. Before using insmod mwave, check /proc/ioports and /proc/interrupts to make sure the resources you intend to claim are not already in use.
3.5. PPP Errors Using 2.4.0 Version of the Kernel
When upgrading to the 2.4.0 version of the kernel be sure to read the ./Documentation/Changes file.
Kernel 2.4.0 requires an upgraded version of the pppd, gcc, and modutils (amoung other things). Follow the instructions for setting up the new pppd daemon carefully.
You may experience some initial problems getting ppp running with 2.4.0. One of the most prevelant errors we received was, "Can't locate module tty−ldisc−3." However, we had no problems once we rebuilt the kernel with the following options:
CONFIG_PPP=y
CONFIG_PPP_ASYNC=m
CONFIG_PPP_SYNC_TTY=m
CONFIG_PPP_DEFLATE=m
CONFIG_PPP_BSDCOM=m
3.5. PPP Errors Using 2.4.0 Version of the Kernel 9
4. Debugging Tips
4.1. Error Logs
Errors encountered by the ACP Modem device driver or application are logged using the syslog utility.
4.2. Tracing
The ACP device driver supports a debug argument to enable the generation of trace information. The command for this debug is listed below. You can also access several of the variables listed below in the mwaved script. insmod mwave mwave_debug=0x0f
Where the following debug trace information is selectable:
0x01 ACP Modem Device driver entry points
0x02 Systems Management API(SMAPI)
0x04 Hardware Interface (3780I)
0x08 Thinkpad Interface (tp3780i)
Trace information is logged using the syslog utility.
The ACP application supports tracing through the use of flags configured in the [STARTUP] section of the mwavem.conf file.
Mwave Manager API trace points:
MANAGER_API_TRACE=1
MANAGER_API_DATA_TRACE=1
MANAGER_CORE_TRACE=1
MANAGER_SPECIFIC_TRACE=1
MEIO Manager trace points:
MEIO_API_TRACE=1
MEIO_CORE_TRACE=1
MEIO_SPECIFIC_TRACE=1
Mwave Modem application trace points:
MWMLW32_TRACE=1
4. Debugging Tips 10
Linux ACP Modem (Mwave) mini−HOWTO
MWMPW32_TRACE=1
MWMUTIL_TRACE=1
MWWTT32_TRACE=1
Trace information is logged using the syslog utility.
4. Debugging Tips 11
5. Test Claims
This driver has been tested using the ThinkPad" 600E. The same chipset is integrated on the 600 and 770 models and should work.
5. Test Claims 12
6. List of Supported Countries
The following countries are supported by the ACP Modem driver
ALGERIA
ANTIGUA_BARBUDA
ARGENTINA
ARMENIA
ARUBA
AUSTRALIA
AUSTRIA
AZERBAIJAN
BAHAMAS
BARBADOS
BELARUS
BELGIUM
BERMUDA
BOLIVIA
BRAZIL
BRUNEI
BULGARIA
CANADA
CAYMAN_ISLANDS
CHILE
COLOMBIA
COSTA_RICA
CUBA
CYPRUS
CZECHREPUBLIC
DENMARK
ECUADOR
EGYPT
Table 1. List of Supported Countries
Country Name
38
57
506
53
357
420
45
593
20
55
673
359
107
108
104
375
32
105
591
297
61
43
994
103
Country
Access Code
213
102
54
374
6. List of Supported Countries 13
EL_SALVADOR
FINLAND
FRANCE
GERMANY
GREECE
GRENADA
GUATEMALA
GUYANA
HONDURAS
HONG_KONG
HUNGARY
INDIA
INDONESIA
IRELAND
ISRAEL
ITALY
JAMAICA
JAPAN
JORDAN
KOREA
KOREA_SOUTH
KUWAIT
LUXEMBOURG
MALAYSIA
MEXICO
NETH_ANTILLES
NETHERLANDS
NEW_ZEALAND
NICARAGUA
NORWAY
OMAN
PAKISTAN
PANAMA
PARAGUAY
PERU
6. List of Supported Countries
Linux ACP Modem (Mwave) mini−HOWTO
81
962
850
82
965
62
353
972
39
112
592
504
852
36
91
503
358
33
49
30
111
502
64
505
47
968
92
352
60
52
599
31
507
595
51
14
PHILIPPINES
POLAND
PORTUGAL
PRC
ROMANIA
RUSSIA
SAUDI_ARABIA
SINGAPORE
SLOVAKIA
SLOVENIA
SOUTH_AFRICA
SPAIN
ST_KITTS_NEVIS
ST_LUCIA
ST_VINCENT
SURINAME
SWEDEN
SWITZERLAND
TAIWAN
THAILAND
TRINIDAD_TOBAGO
TURKEY
TURKS_CAICOS
U_K
UKRAINE
UNITED_ARAB_EMIRATES
URUGUAY
USA
VENEZUELA
VIETNAM
VIRGIN_IS_BRITISH
VIRGIN_IS_USA
YEMAN
YUGOSLAVIA
Linux ACP Modem (Mwave) mini−HOWTO
41
866
66
117
90
115
122
116
597
46
65
421
386
27
34
63
48
351
852
40
7
966
1
58
84
106
123
967
381
118
44
380
971
598
6. List of Supported Countries 15
7. Trademarks
Hayes is a trademark of Hayes Microcomputer Products, Inc.
MNP (Microcom Network Protocol) is a trademark of Microcom, Inc.
IBM is a trademark of International Business Machines, Inc.
7. Trademarks 16
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement
Table of contents
- 3 1. General Information and Hardware Requirements
- 3 1.1. Introduction
- 3 1.2. Credits
- 3 1.3. Where Can I Get the Latest Version of this Driver?
- 3 1.4. Are There Any Other Resources?
- 3 1.5. Copyright Notice and Disclaimer
- 4 1.6. Which Systems are Supported
- 4 1.7. Features of the Modem
- 5 2. Compilation, Installation, and Startup
- 5 2.1. Prerequisites
- 5 2.2. Building and Installing Source
- 5 2.3. Setting Things Up
- 6 2.4. Runtime
- 6 2.4.1. Loading the ACP device driver
- 7 2.4.2. Running ACP Modem Application
- 9 3. Resolving Installation and Configuration Problems
- 9 3.1. DSP Does Not Start
- 9 3.2. Resource Conflicts
- 10 3.3. Not Connecting at Specified Starting Speed
- 10 3.4. Dialer Application Cannot Detect Serial Port
- 11 3.5. PPP Errors Using 2.4.0 Version of the Kernel
- 12 4. Debugging Tips
- 12 4.1. Error Logs
- 12 4.2. Tracing
- 14 5. Test Claims
- 15 6. List of Supported Countries