- Computers & electronics
- Computer components
- System components
- Processors
- Eclipse
- EC-P50
- Installation manual
advertisement
▼
Scroll to page 2
of
52
EC-P50 10-50 Zone Intruder Alarm System Installation Manual Contents 1. System Overview ........................................... 4 System Configuration ............................................................. 4 Control Panel .......................................................................... 5 Remote Keypads .................................................................... 5 EC-LED Remote Keypad ............................................................ 5 EC-LCD Remote Keypad ............................................................ 5 Expansion Modules ................................................................ 5 EC-EX10 Zone & Output Expander ........................................... 5 EC-EX10/I Zone Expander ........................................................ 5 EC-EX10/O Output Expander .................................................... 5 EC-COM/IP Communication Module ...................................... 5 EC-USB-Link ............................................................................ 5 Upload/Download Software ................................................... 5 Zone Attributes ........................................................................ 20 Zone Areas ............................................................................... 21 Zone Bypass Options .............................................................. 21 Zone Chime.............................................................................. 21 Zone Soak Test........................................................................ 21 Zone Text ................................................................................. 21 Zone Link ................................................................................. 21 2. Area Options ..................................................................... 22 Area Timers .............................................................................. 22 Area Arming Modes ................................................................. 22 Area Configuration Options 1 ................................................. 22 Area Configuration Options 2 ................................................. 23 Area Keyswitch Control ........................................................... 23 Area Timer Control .................................................................. 23 3. System Configuration ....................................................... 24 2. Installation ..................................................... 6 System Timers ......................................................................... 24 Installation Sequence............................................................. 6 Control Panel .......................................................................... 6 Hardware - Volume Levels ...................................................... 25 Mounting .................................................................................... 6 Wiring the Control Panel ........................................................... 6 Control Panel Layout ................................................................. 7 PCB Layout ................................................................................. 8 Connecting Devices to the Network ....................................... 10 Remote Keypads .................................................................. 11 PCB Layouts ............................................................................. 11 Wiring Detection Devices ..................................................... 11 Normally Closed ....................................................................... 11 Normally Open ......................................................................... 11 Single EOL - N/C ...................................................................... 12 Double EOL............................................................................... 12 Triple EOL ................................................................................. 12 Loudspeaker Connections ................................................... 12 External Sounder/Strobe Connections ................................ 13 System Counters ..................................................................... 24 Output Monitoring ................................................................... 25 Hardware Monitoring .............................................................. 25 System Configuration 1 .......................................................... 25 System Configuration 2 .......................................................... 26 Control Timers ......................................................................... 26 Banner Text ............................................................................. 26 Area Labels .............................................................................. 26 Remote Control Labels ........................................................... 26 Voice Options ........................................................................... 26 Activate by Link Control .......................................................... 26 Voice Message Options .......................................................... 26 System Links ........................................................................... 27 4. Keypad Configuration ...................................................... 27 Keypad Options 1 .................................................................... 27 Keypad Options 2 .................................................................... 27 Keypad Sounds ....................................................................... 28 TR .............................................................................................. 13 Keypad Areas .......................................................................... 28 0V .............................................................................................. 13 5. Expander Configuration ................................................... 29 +12 ........................................................................................... 13 Expander Areas ....................................................................... 29 Bell (1) ...................................................................................... 13 Strobe (2) ................................................................................. 13 Panel Outputs 1 - 5............................................................... 13 2-Wire Smoke Detectors ...................................................... 13 Telephone Line Connections................................................ 14 Commissioning ..................................................................... 14 Confirm Devices ....................................................................... 14 Expander Options .................................................................... 29 Expander Sounds .................................................................... 29 Expander Outputs ................................................................... 29 Expander Output Attributes .................................................... 29 Expander Output Areas ........................................................... 30 6. Panel Outputs and Devices ............................................. 30 Panel Output Type ................................................................... 30 Power-Up Options Menu.......................................................... 14 Panel Output Attributes .......................................................... 30 3. Programming the Control Panel ................ 15 Output Types ........................................................................... 31 Introduction........................................................................... 15 Exiting Engineer’s Program Mode ........................................ 15 Menu Navigation and Data Entry ......................................... 16 LCD Navigation ........................................................................ 16 Selection List ............................................................................ 16 Bit Toggle Selection ................................................................. 17 Number Entry ........................................................................... 18 String Edit - Number Mode ..................................................... 18 String Edit - Text Mode ............................................................ 19 1. Zone Programming ........................................................... 19 Zone Type ................................................................................. 19 Zone Wiring .............................................................................. 20 2 Panel Output Areas ................................................................. 31 00: Global ................................................................................ 31 Group 02: Control Timer ......................................................... 32 Group 03: Remote Control ..................................................... 32 Group 04: Link Control ........................................................... 32 Group 10: Zone Count ............................................................ 33 Group 20: Zone Mimic ............................................................ 33 Group 30: Zone Alarm ............................................................ 33 Group 40: Zone Tamper ......................................................... 34 Group 50: Zone Masked......................................................... 34 Group 60: Zone Fault.............................................................. 34 Group 70: Zone Bypassed ...................................................... 34 Group 80: User Access ........................................................... 34 Communication Ports ............................................................. 34 P0016-LI-03.01 GSM & SMS Centre ................................................................. 34 Print Event Log IP Configuration ....................................................................... 35 Call UDL 22* ....................................................... 43 23* .................................................................. 43 7. On-board Communicator.................................................. 36 Chime on/off 24* .......................................................... 43 ARC 1-4: Telephone Number .................................................. 36 Change Code 81* .......................................................... 43 ARC 1-4: Account Number ...................................................... 36 Program Mode ARC 1-4: Protocol ..................................................................... 36 View Zone Status 92* ................................................... 43 ARC 1-4: Protocol Options ....................................................... 36 Confirm Devices 98* ..................................................... 43 ARC 1-4: Call Sequence/Attempts ......................................... 36 ARC 1-4: Reported Event Groups ........................................... 36 ARC 1-4: Cancel on Success ................................................... 37 ARC 1-4: Areas ......................................................................... 37 ARC 1-4: IP Address ................................................................. 37 ARC 1-4: IP Port Number ......................................................... 37 Exit Menu 91* ........................................................ 43 99* ................................................................ 43 Log Events ............................................................................ 44 LED Indications..................................................................... 47 Fault & Status Messages ..................................................... 47 Resetting Faults & alarms ...................................................... 47 Options: Auto Test Call Period ................................................ 37 4. Specifications .............................................. 47 Options: Auto Test Call Time ................................................... 37 EC-P50 Control Panel ........................................................... 48 Options: Auto Test Days .......................................................... 37 Options: PSTN Pre-Dial Number ............................................. 37 Fast Format: Reporting Channels .......................................... 38 Fast Format: Restore Channels .............................................. 38 Fast Format: Open/Close Channels ....................................... 38 Channel Type ........................................................................... 39 Channel Attributes ................................................................... 39 Channel Areas .......................................................................... 39 Speech Dialler: Telephone Numbers 1 and 2 ....................... 39 Speech Dialler: Dial Sequence ............................................... 39 Speech Dialler: Trigger Type ................................................... 39 UDL Options ............................................................................. 39 UDL Password .......................................................................... 40 UDL Ring Count ........................................................................ 40 Call-Back Number .................................................................... 40 UDL Dial Sequence .................................................................. 40 UDL Remote IP Address .......................................................... 40 UDL Remote IP Port ................................................................. 40 UDL Account Number .............................................................. 40 8. System Users .................................................................... 41 User Access Code .................................................................... 41 User Type .................................................................................. 41 User Locked By ........................................................................ 41 User Name ............................................................................... 41 User Link................................................................................... 41 User Areas ................................................................................ 41 9. Utilities .............................................................................. 42 Time and Date.......................................................................... 42 User Menus ........................................................................... 42 Away Arm A......................................................................... 42 Stay Arm S .......................................................................... 42 Walk Test 11* ................................................................. 42 Test Bell & Outputs Do Test Call View Event Log P0016-LI-03.01 12*................................................. 42 13* ............................................................. 42 21* ........................................................ 43 Electrical .................................................................................. 48 Environmental ......................................................................... 48 Physical .................................................................................... 48 EC-LED Remote Keypad ....................................................... 48 Electrical .................................................................................. 48 Environmental ......................................................................... 48 Physical .................................................................................... 48 EC-LCD Remote Keypad ....................................................... 48 Electrical .................................................................................. 48 Environmental ......................................................................... 48 Physical .................................................................................... 48 EC-EX10/I Zone Expander ................................................... 48 Electrical .................................................................................. 48 Environmental ......................................................................... 48 Physical .................................................................................... 48 EC-EX10 Zone & Output Expander ...................................... 48 Electrical .................................................................................. 48 Environmental ......................................................................... 48 Physical .................................................................................... 49 EC-EX10/O Output Expander ............................................... 49 Electrical .................................................................................. 49 Environmental ......................................................................... 49 Physical .................................................................................... 49 EC-COM/IP Communication Module ................................... 49 Electrical .................................................................................. 49 Environmental ......................................................................... 49 Physical .................................................................................... 49 Standards ............................................................................. 49 Safety ....................................................................................... 49 EMC .......................................................................................... 49 Security .................................................................................... 49 Warranty ............................................................................... 49 Notes ..................................................................................... 50 Notes ..................................................................................... 51 3 1. System Overview System Configuration 4 P0016-LI-03.01 Control Panel Expansion Modules The EC-P50 control panel is an advanced intruder alarm system with 10 on-board zones and on-board multi format communicator. The system can be expanded to 50 zones using the 10 zone expansion modules (EC-EX10 or EC-EX10/I). The EC-EX10/O can be used where additional programmable outputs are required. The system supports 5 partitions and 50 user codes and is ideal for multi-area and multi-tenant applications within domestic and commercial installations. The following expansion modules are available: f 10 fully programmable zone inputs The control panel provides a multi-channel integrated speech dialler and voice annunciation feature. Voice messages are recorded via a touch tone telephone or by using the Eclipse UDL software package. f 10 programmable outputs (8 x 100mA; 2 x 1Amp) f Internal piezo sounder f 16Ω loudspeaker connection, with programmable volume f Tamper protection f Engineer keypad port f Stylish housing Remote arming and disarming and system control can also be carried out by calling the protected premises with a touch-tone telephone. On answering the incoming call you are greeted with a voice prompted menu. The system can be further enhanced by using the EC-COM/IP module which provides both IP and X-10 connectivity. X-10 is a simple home automation protocol that uses the existing mains wiring to communicate with X-10 compatible devices via a XM10U controller. Once the EC-COM/IP is installed, both the system and X-10 devices can be controlled remotely using smart phone apps. EC-EX10 Zone & Output Expander The EC-EX10 is a housed zone and output expansion module that is connected to the 4-wire control panel network. Features include: EC-EX10/I Zone Expander The EC-EX10/I is a housed zone expansion module that is connected to the 4-wire control panel network. Features include: f 10 fully programmable zone inputs A choice of either LCD or LED remote keypads is available. Other features include: f Tamper protection f Stylish housing f 10 programmable on-board zones EC-EX10/O Output Expander f 5 programmable outputs (1Amp rated) f On-board communicator/modem/speech dialler The EC-EX10/O is a housed output expansion module that is connected to the 4-wire control panel network. Features include: f Local or remote upload/download f 1000 event log f Advanced system diagnostics f 1.5 Amp switched mode power supply f Two communication ports for accessories etc f Loudspeaker output The EC-COM/IP is an IP based communicator and X-10 home automation interface PCB module. Features include: f Selectable battery charging rate f Ethernet connection to LAN/WAN f Real time clock f Remote access via Eclipse UDL or smart phone app f Two-wire smoke detector support f Alarm reporting via LAN/WAN to PC based alarm receiver f Flash upgradable f X-10 port for automating X-10 devices via the XM10U/E f X-10 devices controlled via the system or smart phone app f PCB module clips into EC-P50 control panel housing Remote Keypads The EC-P50 will accept up to a maximum of 6 remote keypads. All remote keypads require a 4-wire connection to the control panel using standard alarm cable. The following models are available: EC-LED Remote Keypad The LED keypad features a dual 7 segment display for displaying zone status and system fault messages. A set of dedicated system status LEDs for AC, Ready, Armed, Trouble, Bypass, Alert and Alarm are also provided. Other features include: f 10 programmable outputs (8 x 100mA; 2 x 1Amp) f Tamper protection f Stylish housing EC-COM/IP Communication Module EC-USB-Link The EC-USB-Link provides USB connectivity between the EC-P50 and the host computer. It is required when a direct connection is required between the Eclipse UDL software package and the ECP50. f Internal sounder Upload/Download Software f Backlit keyboard Eclipse UDL is a Windows® based software package that can be used to remotely or locally program and diagnose the Eclipse range of security systems. Features include: EC-LCD Remote Keypad The LCD keypad features a 2 x 20 character blue display for showing all zone status and system fault messages. A set of dedicated system status LEDs for AC, Trouble and Alert are also provided. Other features include: f Internal sounder f Backlit keyboard P0016-LI-03.01 f Simple intuitive user interface f Local or remote via modem and IP f System remote control f Advanced system diagnostics 5 f Multi language support 2. Installation Installation Sequence Before attempting to install the alarm system, read this section. Once you have an overall understanding of the installation sequence, carefully work through each step. 1. Design the Layout Make a rough sketch of the premises to get an idea of where all alarm detection devices, keypads and other modules are to be located. 2. Mounting the Control Panel The control panel must be mounted within the protected area close to an unswitched AC power source and the incoming telephone line. You must complete all wiring before connecting the battery, or applying AC to the panel. 3. Install the Remote Keypads Mount the remote keypads at locations that are easily accessible during entry and exit from the protected area. Connect the remote keypads to the control panel. 4. Zone Wiring Install detection devices and connect to control panel or expander. Wiring the Control Panel WARNING: ELECTRICITY CAN KILL BEFORE connecting the control panel ALWAYS disconnect the supply at the consumer unit. If in ANY doubt consult a qualified electrician. ONLY connect the mains supply to the mains terminal block, NEVER connect the mains supply directly to the PCB. The system installation MUST be carried out in accordance with the national safety standards, for example EN 60950: 1992. ALWAYS refer to National Wiring Regulations when conducting installation. An appropriate and readily accessible disconnection device (e.g. an unswitched fused spur) MUST be provided as part of the installation. The disconnection device must NOT be fitted in a flexible cord. 5. Other Wiring Complete all other wiring including external/internal sounders and telephone line connections. Where identification of the neutral in the mains supply is NOT possible, a two-pole disconnection device MUST be used. 6. Apply Power to the Control Panel Once steps 1 to 5 are completed, apply power to the control panel. First, connect the red battery lead to the positive terminal and the black lead to negative. Then, connect the AC. The building mains supply MUST incorporate appropriate short-circuit backup protection (e.g. a fuse or circuit breaker) of High Breaking Capacity (HBC, at least 1500A). 7. Program the System If available use the Eclipse UDL software package to program the system, if this is not available program this system in accordance with the procedures in Section 3. Use mains cable of adequate carrying capacity for the rated current (i.e. at least 0.75mm2). 8. Testing the System Test the system thoroughly to ensure that all features and functions are operating as required. Control Panel Mounting Mount the control panel on a flat, plumb wall using at least three appropriate screws. The rear casing has been designed with a central key-hole slot so that mounting is possible without removing the Printed Circuit Board (PCB). The angled slot in the lower corner has been provided to allow the panel to be levelled easily. If the PCB has to be removed, carefully pull back the two front PCB securing clips, lift the front of the PCB and slide it downward. To replace the PCB simply reverse the above procedure. It is essential to ensure that none of the fixing slots or cable entries are accessible after fixing. Mains cabling must be secured (e.g. with a cable tie) to one of the anchor points provided. 6 P0016-LI-03.01 Control Panel Layout 1 5 2 3 4 1. Main Printed Circuit Board (PCB) The main PCB that provides the terminals connection to remote keypads and detection devices, see PCB Layout on next page for full details. 2. Switched Mode Power Supply The switch mode power supply module is housed under this protected area and provides power to the main PCB via the threeway harness. 5. Communication Module An optional Eclipse Communication Module can be clipped into the housing under the main PCB. 6. Standby Battery The system housing will accept a 12V 7Ah battery to provide continued operation in the event of an AC mains failure. Connect the red battery lead to the positive terminal of the battery and then connect the black battery lead to the negative terminal. Control Panel E L R 12V 7Ah Sealed Lead Acid Battery BAT N To Power Supply Module Network D 3. Mains Connection The AC Mains supply is connected to a 3 way Euro Type fused terminal block, which is fitted with a 500mA fuse. 6 Fuse T500mA 4. Mains Supply Cable Entry The mains supply cable must be routed into the control panel housing via this cable entry. P0016-LI-03.01 The system will only become “live” when the AC supply is connected or the “Battery On” pins are shorted, see item 18 of PCB layout. 7 PCB Layout 18 16 17 16 16 15 14 13 1 12 2 3 4 5 6 7 1. PSU Connector The harness from the switched mode power supply module plug onto this connector and provides the power (13.7V) to power the system. 2. Engineer’s Remote Keypad Connector An engineer’s remote keypad maybe plugged onto to this connector so that system programming and testing can be carried out at the location of the control panel. 3. Lid Tamper Switch This switch detects when the cover is in position and the screw is fully secured. The tamper is designed to activate when the screw is undone. 6 8 9 10 11 10. External Sounder 12V These terminals provide power for external sounder units. The output is protected by an auto resetting fuse (PTC) rated at 1.1A. 11. Panel Outputs 1 to 5 These are fully programmable high current (1 Amp), switched negative supervised outputs. Panel outputs 1 and 2 default to bell and strobe operation, but can be programmed for other functions if required, see page 30 for programming details. Each output can also be programmed for supervision monitoring, see page 25. 12. Two-Wire Smoke Detector Enable Set this link as shown when connecting 2-wire smoke detectors to Panel Output 5. 4. Battery Connections A 12V rechargeable battery must be connected to these two terminals in order to provide continuous system operation in the event of mains failure. The battery output is protected by an auto resetting fuse (PTC) rated at 1.6 Amp. 2-wire Smoke Detectors Enabled: Panel Output 5 must be programmed as “2-wire Smoke” (0047) and smoke detectors must be connected as shown page 13. 5. Network Connections The network terminals provide connections to the remote keypads and zone expanders. The + and – terminals provide power whilst the R and R terminals are the data signals. 2-wire Smoke Detectors Disabled: Panel Output 5 will function as a normal output. 6. Zone Inputs 1 to 10 Detection devices such as movement sensors, vibration and door contacts are connected to the zone input terminals. There are several ways in which to wire a detection device (see page 11). Each zone is fully programmable, see page 19 for information on programming zones. 13. Communication Ports 1 and 2 Two serial communication ports 1 and 2 are provided for local downloading and for third party devices. 7. Auxiliary 12V These terminals provide auxiliary power for detection devices that require 12V power, e.g., moment sensors. The auxiliary output is protected by an auto resetting fuse (PTC) rated at 1.1 Amp). 8. Speaker These terminals are used for driving 16Ω extension loudspeakers (see page 12). 9. Bell Tamper Return This terminal is connected to the tamper return connection from an external sounder unit. If it is not required link it to 0V. 8 14. RJ11 Telephone Line Connector An RJ11 connector is provided so that the panel can be connected to the telephone line via a standard RJ11 patch lead. 15. Telephone Line Connections Telephone line connections (see page 14). 16. Power/Status LED On steady when either AC or standby battery is present. Flashes when the on-board communicator is dialling or sending data. 17. Battery Charging Rate The standby battery can be recharged at different rates: P0016-LI-03.01 300mA: This is the recommended charge rate for a 7Ah standby battery. The system will fully recharge a flat battery within 24hours. 750mA: This is the recommended charge rate for a 17Ah standby battery. The system will fully recharge a flat battery within 24hours. 18. Battery On (Kick Start) When powering the system from battery only, the “Battery On” pins must be momentarily shorted together with a plain blade screwdriver or similar to kick start the power supply into operation. P0016-LI-03.01 9 Connecting Devices to the Network Network Connections The network is made up of four terminals incorporating power and data. To ensure correct operation, all four terminals on the device must be connected to the corresponding terminals on the control panel, or previous device. The table below shows each terminal and its description: Before connecting devices to the control panel network, isolate ALL power from the control panel (AC Mains & Battery). Do not continue if there is still power present on the control panel. Connecting devices with power still present on the control panel may damage the device or control panel and invalidate any warranty. Remote keypads and expanders are all connected to the same network terminals located at the bottom left hand corner of the control panel and may be connected serially (daisy chain), in parallel (star) or any combination of the two. + +12V Supply - 0V Supply R Data Return D Data I/O 500 metres Remote Keypad Remote Keypad Zone & Output Expander Remote Keypad Address = 1 Address = 2 Address = 1 Address = 3 IN 12V 0V R 12V 0V R D 12V 0V R D OUT D 12V 0V R 12V 0V R D D R D Control Panel Network To additional devices Overcoming Voltage Drop There are several ways to overcome voltage drop: Cable Type and Distances For improved immunity to electrical noise, the use of screened 4 core cable is recommended. The screen should be twisted together and wired into the (–) terminal at the control panel only. The maximum recommended distance for devices when using standard 7/0.2 alarm cable is: f 250m for each branch when using the star (parallel) configuration f When using a daisy chain (series) configuration the maximum distance will depend on the number of devices connected on the chain. The more devices that are connected, the shorter the distance to the last device (this is due to voltage drop in the cable) f Use thicker lower resistance cable. Standard 7/0.2 alarm cable has a resistance of 8Ω per 100m f Double up on the power connections – this will require using a 6 or 8-core cable rather than a 4-core cable f Install a power supply to power the device locally, remember to common the two negative connections Installing a Power Supply When a power supply is installed, the 0V connections on the power supply must be connected through to 0V on the control panel and the +12V connection between the control panel and the device must be disconnected (see figure below). Whichever method of wiring configuration is used, ensure that the voltage between the ‘+’ and ‘–’ terminals at each device is no lower than 10.0V when the system is running on the standby battery. 1km 500 metres Remote Keypad Zone & Output Expander Remote Keypad Address = 1 Address = 1 Address = 2 IN 12V 0V R D 12V 0V R OUT D 12V 0V R D 12V 0V R D R D Control Panel Network Disconnect +12V from control panel 12V 0V Power Supply 10 P0016-LI-03.01 Remote Keypads Wiring Detection Devices PCB Layouts The EC-P50 provides 10 zones for connecting detection devices such as movement sensors and magnetic door contacts. Each zone is fully programmable to allow for maximum flexibility (see page 19 for Zone Programming details). The program options for a zone will also determine how the zone may be wired. The following wiring options are available: 2 1 Normally Closed This wiring configuration should be used when connecting detection devices that only have a normally closed alarm output. Connect the detector as shown below and ensure that the zone is programmed for “Normally Closed” operation, see page 20. 3 Zx Com Zy 4 LED Remote Keypad Alarm Alarm 1 Detector 1 Alarm 2 2 Detectors Normally Open 4 This wiring configuration should be used when connecting detection devices that only have a normally open alarm output. Connect the detector as shown below and ensure that the zone is programmed for “Normally Open” operation, see page 20. Zx Com Zy 3 LCD Remote Keypad 1. Network Connections The remote keypad is connected to the network terminals located at the bottom left hand side of the PCB. 2. Address Selection Each remote keypad must be assigned a different address using the Address selector. Move the jumper to the required position 1, 2, 3 or 4. 3. Tamper Switch The lid tamper for each remote keypad can be enabled or disabled if required. Please refer to page 27 for further details. 4. Piezo Sounder The piezo sounder generates low level alarm, key press, and warning tones. Each type of tone can be enabled or disabled for each remote keypad, please refer to page 28 for further details. Alarm Alarm 1 Detector Alarm 2 Detectors P0016-LI-03.01 11 Single EOL - N/C Triple EOL This wiring configuration should be used when connecting detection devices that only have a normally closed alarm output. Connect the detector as shown below and ensure that the zone is programmed for “Single EOL – N/C” operation, see page 20. This wiring configuration should be used when connecting detection devices that support triple EOL configuration, this will allow the system to monitor alarm, tamper fault and mask. Connect the detector as shown below and ensure that the zone is programmed for “Triple EOL” operation, see page 20. Zx Com Zy Alarm 2K2 Alarm Fault 4K7 Zx Com Zy Alarm 3K3 1 Detector Alarm 3K3 Tamper 2 Detectors 2K2 E.O.L 1 Detector Double EOL This wiring configuration should be used when connecting detection devices that have a normally closed alarm and tamper output. Connect the detector as shown below and ensure that the zone is programmed for “Double EOL” operation, see page 20. Zx Com Zy Loudspeaker Connections SPK The EC-P50 has a loudspeaker output capable of driving one 16Ω or two 8Ω wired in series as shown below: Alarm Tamper Tamper SPK Alarm 4K7 4K7 16Ω Loudspeaker 8Ω Loudspeaker 2K2 E.O.L Alarm 4K7 1 Detector 8Ω Loudspeaker The volume level can be programmed, please refer to page 25 for details. The loudspeaker can also be tested, please refer to page 25 for further details. Tamper 2K2 E.O.L 2 Detectors 12 P0016-LI-03.01 External Sounder/Strobe Connections Panel Outputs 1 - 5 The following connections are available for connection to an external sounder/strobe unit: The control panel has five programmable outputs, which can be used to drive auxiliary devices such as LEDs, sounders or relays etc. (see page 30 for details on programming outputs). Each panel output is rated at 1 Amp and switches to 0V when active. The figure bellow shows some wiring examples: Tamper Return input. Connect to the tamper output on the external sounder/strobe unit. If this input is not used it must be linked to 0V. 0V cathode 12V 0V supply. Connect to the 0V (-) supply on the external sounder/strobe unit. Control Panel OP TR +12 Positive 12V supply, which is protected by an auto resetting fuse (PTC) rated at 1.1A. Connect to the +12V (+) supply on the external sounder/strobe unit. Panel output 1 is pre-configured for Bell operation, i.e. it switches to 0V when active. Connect this terminal to the bell trigger input on the external sounder/strobe unit. The output can be inverted for SCB operation, see page 30 for details. LED Indicator Control Panel 12V Relay 12V Strobe (2) LED OP Bell (1) anode 1K + Panel output 2 is pre-configured for Strobe operation, i.e., it switches to 0V when active. Connect this terminal to the strobe input on the external sounder/strobe unit. Control Panel Relay Driver External Sounder OP +12V Suppy 12V Buzzer 12V 2 1 Bell -ve TR 0V 12V Control Panel Strobe -ve 0V + Tamper Buzzer Driver 2-Wire Smoke Detectors A maximum of 10, 12V 2-wire smoke detectors can be connected to the control panel using panel output 5. The detectors must be connected as shown below. The Enable 2-wire jumper link must be set as shown and the output must be programmed for “2-wire Smoke” (0047) operation, see page 30 for details. A Maximum of 10 2-Wire Smoke Detectors can be connected to panel output 5 0V V Out 0V V Out E.O.L 12V 1K 5 Control Panel V In P0016-LI-03.01 V In 13 Telephone Line Connections f Replace the lid and secure with the lid screw supplied - do not over-tighten. The control panel has an advanced on-board communicator and modem, which can be used for the following: f Enter *99 to leave the programming menus. f The Service light will be flashing to indicate that action is required. Switch on the mains supply to the control panel. The Service light will stop flashing and stay on continuously. f Sending digital alarm status information to an alarm receiving centre using industry standard protocols f Sending voice messages to a mobile or landline telephone f Remote uploading/downloading via Eclipse UDL software package If any of these features are used, a permanent telephone connection should be made to the control panel as shown: Control Panel T1 Installation is now complete and the system is ready for use. Please ensure the system users are provided with adequate training on operating the alarm system. Confirm Devices When the system is powered up, the devices connected to the control panel network must be confirmed. If the network configuration changes after confirmation, the system will show “Confirm Devices”: Confirm Devices 14:15 31/10/2011 Out to premises telephone R1 T In from telephone provider R Enter Engineers code ???? Engineers Menu Location:---- No of keypads Once ALL connections have been made to the control panel and power is ready to be applied, you should read this section before continuing. Keypads: L7-Expanders: E--- O--Press * to confirm devices. The control panel leaves the factory programmed with default settings and when the system is powered up for the first time the default settings are in use. If the factory defaults need to be reloaded in the future, please see “Power-up Options Menu”. f Connect the black battery lead to the negative (–) terminal of the standby battery and the red battery lead to the positive (+) terminal of the standby battery. The green power LED on the main PCB will light. f If the system enters into an alarm condition, enter the default master user code 5678. The alarm tone will then stop. f To access the Engineer Programming Menu, enter the default engineer code 1234. The remote keypads will show: LED Engineers Menu Location:---- Confirm that all devices connected to the control panel are being recognized; see “Confirm Devices” below. f Program the system as described in the next section (Programming the Control Panel). f Carry out a walk test as described on page 42. Remember that some powered detectors (e.g. PIRs and combined technology detectors) take several minutes to warm up before they become operational. 14 22 No of Expanders Key: L=EC-LCD Keypad 7=EC- LED Keypad E=EC-EX10 Expander I=EC-EX10/I Expander O=EC-EX10/O Expander Power-Up Options Menu When power is applied to the system, the control panel enables the “Power-Up Options Menu” for 10 seconds. During this period the control panel status LED flashes between red and green and the system will accept the following commands: Command Description *0# Default Engineer Code Entering this command will set engineer access code back to 1234. *3# Save as Factory Defaults Entering this command will save the current control panel program configuration as the NEW factory default profile. *6# Set UDL Password Entering this command will set the UDL password to 123456. *9# Load Factory Defaults Entering this command will set all control panel program configuration options to the factory default settings. LCD f f En Enter 98* Commissioning En Cd Test the internal sounder, external sounder and strobe as described on page 42. P0016-LI-03.01 3. Programming the Control Panel Section Introduction This section covers the system programming and it is important that all engineers read this section carefully so as to familiarise themselves with the many features and functions of the control panel. To access the programming menu, enter the factory default engineer code 1234. If a mistake is made whilst entering the code, simply re-enter the code correctly. When the system is in Engineers Mode, ALL zones and tampers are disabled. Each programming option is accessed by a four digit location number followed by *. The location numbers have been grouped together into logical sections. The programming sections are: Section Page 1 Zone Programming 1 Zone Types 2 Wiring 3 Zone Attributes 4 Zone Areas 5 Bypass Options 6 Chime Options 7 Soak Test 8 Zone Text 9 Zone Links 19 2 Area Options 1 Area 1 Options 2 Area 2 Options 3 Area 3 Options 4 Area 4 Options 5 Area 5 Options 22 3 System Configuration 1 System Timers 2 System Counters 3 Hardware Options 4 Configuration 5 Control Timers 6 Banner Text 7 Voice Message Links 8 Voice Message Options 9 System Output Links 24 4 Keypad Options 11 Keypad Options 1 12 Keypad Options 2 13 Keypad Sounds 14 Keypad Areas 27 5 Expander Options 10 Expander Areas 11 Expander Options 12 Expander Sounds 2 Expander Output Type 3 Expander Output Attributes 29 6 System Devices 1 Panel Outputs 2 Com Ports 3 GSM & SMS Centre 4 TCP/IP Configuration 30 P0016-LI-03.01 Page 7 On-board Communicator 0 ARC 1 - 4 Configuration 1 Options 2 Fast Format 3 Speech Dialler 4 UDL Options 36 8 Users 1 User Code 2 User Type 3 User Time Locks 4 User Name 5 User Link 6 User Areas 41 9 Utilities 0 Set Time and Date 42 Exiting Engineer’s Program Mode To exit the engineers programming menus and return to the normal disarmed mode, ensure the display is prompting you to enter a location number then enter 99*. 15 Menu Navigation and Data Entry LCD sub menu navigation Enter Engineers code 1234 Each programming location is accessed by entering its four digit location number followed by *. If you don’t know the exact location you can enter less than four digits and the panel will take you to the first location that starts with numbers you have entered. For example if you enter 12 the panel will take you to location 1201 – Zone 01 Wiring Type. Engineers Menu Location:---A =Next(up) S =Previous (down) * =Select section LCD Navigation If the system is fitted with an LCD keypad, you can navigate through the main menu using the following keys: Engineers Menu: 1101 Zone Setup A = Next program section * S = Previous program section Zone 01 Type Final Exit 1 * = Select location of displayed section R = Back a menu level Zone 01 Wiring Normally Open LCD main menu navigation Enter Engineers code 1234 Zone 01 Attributes1 .2..5.. Engineers Menu Location:---- A S A =Next(up) S =Previous (down) * =Select section Engineers Menu: 1101 Zone Setup Engineers Menu: 2001 Away/Stay Options Engineers Menu: 3101 Global Options Engineers Menu: 3501 Control Timers Engineers Menu: 3601 System Text Engineers Menu: 3701 Voice/System Links A S Engineers Menu: 4111 Keypad Options Engineers Menu: 5111 Expander Options Engineers Menu: 6111 Panel Outputs Engineers Menu: 7001 ARC Options Engineers Menu: 7311 Speech Dialler Section start location Section description Section start location Section description Zone 01 Bypass 12..... A = Next(up) S = Previous (down) * = Previous location # = Next location R = Back a menu level Zone 01 Chime Off Zone 01 On Test No Zone 01 Text Front Door Zone 01 Link 000 Selection List This type of data entry is used when selecting an option from a predefined list. Each item in the list has a number and associated description. When using the LCD keypad for programming the description is displayed. The LED keypad can only display the number. The figures below show the programming procedure for both LED and LCD remote keypads: Selection List: LED Keypad Enter Engineers code ???? En Enter location No ???? e.g. 1101 1 1 0 1 Press * to display the current value Engineers Menu: 7400 UDL Options 1 1 0 1 =1 Engineers Menu: 8100 User Codes Location number & current value are displayed. Enter item number, e.g., 04 Engineers Menu: 9001 Adjust Clock 16 P0016-LI-03.01 1 1 0 1 =4 Press * to accept and return to step Ì Press R to cancel and return to step Ê Press # to accept and move to next location Selection List: LCD Keypad Enter Engineers code ???? Engineers Menu Location:---Enter location No ???? e.g. 1101 Engineers Menu Location:1101 Press * to display the current value Zone 01 Type Final Exit 1 Press B to scroll through list options or enter item number, e.g., 04 Zone 01 Type Intruder To display the item number press and hold any number key. Zone 01 Type 04 Press * to accept and return to step Ì Press R to cancel and return to step Ê Press # to accept and move to next location. Bit Toggle Selection This type of data entry is used for enabling and disabling up to 8 options. Each option is represented by a number 1 to 8 and has an associated description. When using the LCD keypad for programming the description can be displayed by holding down the bit option number, the LED keypad can only display the number. The figures below show the programming procedure for both LED and LCD remote keypads: Bit Toggle Selection: LED Keypad Enter Engineers code ???? En 1 3 0 1 =2 =5 Location number & current options are displayed. Options 2 & 5 are enabled. Use keys 1 to 8 to toggle options on or off, e.g, press 2 to turn option2 off. 0 = All options off. 9 = All options on. 1 3 0 1 =5 Press * to accept and return to step Ì Press R to cancel and return to step Ê Press # to accept and move to next location Bit Toggle Selection: LCD Keypad Enter Engineers code ???? Engineers Menu Location:---Enter location No ???? e.g. 1301 Engineers Menu Location:1301 Press * to display the current value Zone 01 Attributes 1 .2..5.. Location number & current options are displayed. Options 2 & 5 are enabled. Use keys 1 to 8 to toggle options on or off, e.g, press 2 to turn option2 off. 0 = All options off. 9 = All options on. Zone 01 Attributes 1 ....5.. To display the option description press and hold the option number key. Auto rearm ....5.. Press * to accept and return to step Ì Press R to cancel and return to step Ê Press # to accept and move to next location. Enter location No ???? e.g. 1301 1 3 0 1 Press * to display the current value P0016-LI-03.01 17 Number Entry String Edit - Number Mode: LED Keypad This type of data entry is used for entering numeric values, such as timers. The figures below show the programming procedure for both LED and LCD remote keypads: Number Entry: LED Keypad Enter Engineers code ???? En Enter location No ???? e.g. 3101 3 1 0 1 Press * to display the current value 3 1 0 1 =0 Location number & current value are displayed (0). Enter required value, e.g, 35. 3 1 0 1 =3 5 Press * to accept and return to step Ì ???? En Enter location No ???? e.g. 7011 7 0 1 1 Press * to display the current value 7 0 1 1= Location number & current value are displayed (blank). Enter required value, e.g, 1234. To clear value press * & R 7 0 1 1= 1 2 3 4 Press * to accept and return to step Ì Press R to cancel and return to step Ê Press R to cancel and return to step Ê Press # to accept and move to next location Press # to accept and move to next location Number Entry: LCD Keypad String Edit - Number Mode: LCD Keypad Enter Engineers code ???? Engineers Menu Location:---Enter location No ???? e.g. 3101 Engineers Menu Location:3101 Press * to display the current value System Timers AC Fail:000 Location number & current value are displayed (0). Enter required value, e.g, 35. System Timers AC Fail:035 Press * to accept and return to step Ì Enter Engineers code ???? Engineers Menu Location:---Enter location No ???? e.g. 7011 Engineers Menu Location:7011 Press * to display the current value ARC 1 Account ÿ Location number & current value are displayed (blank). Enter required value, e.g, 1234. To clear value press * & R ARC 1 Account 1234ÿ Press R to cancel and return to step Ê Press * to accept and return to step Ì Press # to accept and move to next location. Press R to cancel and return to step Ê String Edit - Number Mode This type of data entry is used for entering a long string of numbers, such as telephone and account numbers. The figures below show the programming procedure for both LED and LCD remote keypads: 18 Enter Engineers code Press # to accept and move to next location. P0016-LI-03.01 String Edit - Text Mode This type of data entry is used for entering text such as user names and zone text. This mode is designed only for the LCD keypad. The text is entered in the same way as entering text on a mobile telephone. Each key is mapped to one or more letters. Pressing a key will select the first letter, pressing it again will select the next etc. The table below shows the keys to use and the characters that are assigned to them: Key Characters This section covers programming of the detection zones; each zone must be programmed a zone type, wiring type, attributes and areas. Zone Type Each zone must be programmed to the correct type in order for the correct response. Locations: 1 1 2 A B C 2 a b c 3 D E F 3 d e F 4 G H I 4 g h i 5 J K L 5 j k l 6 M N O 6 m n o 7 P Q R S 7 p q 8 T U V 8 t u v 9 W X Y Z 9 w x 0 _ 0 . - ( ) # B 1. Zone Programming Zone 01 to 50: Zone Type. Entry Mode: r s y z The figures below show the programming procedure for LCD remote keypads: Enter Engineers code ???? Engineers Menu Location:---Enter location No ???? e.g. 1801 Engineers Menu Location:1801 Press * to display the current value Zone 01 Text ÿ Location number & current value are displayed (blank). Use text editing keys to enter text, e.g, HALL Zone 01 Text HALLÿ Press * to accept and return to step Ì Press R to cancel and return to step Ê Press # to accept and move to next location. Mode: Selection List (see page 16). 00 Not Used Use this zone type for unused zones, as zone programmed as “Not Used” are not be monitored by the system. Clear all characters String Edit - Text Mode: LCD Keypad 1101 to 1150 01 Final Exit 1 Use this zone type for the main entry/exit detector, normally a magnetic contact on the front door. The zone can be activated during the exit mode without causing a fault. If the system is armed, activation of the zone will start the Entry 1 Delay timer for the relevant arm mode. 02 Final Exit 2 Use this zone type for an alternative entry/exit detector. The zone can be activated during the exit mode without causing a fault. If the system is armed, activation of the zone will start the Entry 2 Delay timer for the relevant arm mode. 03 Walk Through Use this zone type for detection devices along the entry/exit route. This zone type will allow the user to walk past the detector without causing a fault during the exit mode or an Intruder alarm during the entry mode. However, if activated at any other time the zone will cause an immediate intruder alarm. This zone type will also start the entry mode when the system is stay armed. 04 Intruder Use this zone type for detection devices such as PIR’s, vibration detectors, magnetic door contacts etc. This zone type generates an intruder alarm if activated when the system is armed. 05 Perimeter Use this zone type for detection devices such as external PIR’s, IR beams. This zone type generates an intruder alarm if activated when the system is armed. 06 Fire Use this zone type for smoke and heat detectors. This zone type generates a distinctive fire alarm if activated at any time. 07 PA Silent Use this zone type for panic buttons. This zone type generates a silent panic alarm if it is activated at any time. 08 PA Audible Use this zone type for panic buttons. This zone type generates an audible panic alarm if it is activated at any time. 09 Medical Use this zone type for medical alarms. This zone type generates a medical alarm if it is activated at any time. 10 24 Hour Use this zone type for detectors that require 24 hour monitoring. This zone type generates an intruder alarm if it is activated when the system is armed. If activated during the disarmed state an internal alarm is generated. 11 Tamper Use this zone type for tamper protection. This zone type generates a tamper alarm if it is activated when the system is armed. If P0016-LI-03.01 19 activated during the disarmed state an internal alarm is generated. 1 Normally Open Use this wiring type for normally open detection devices. 12 Exit Terminator Use this zone type for external push to set buttons. This zone type terminates the exit delay when activated during exit mode. The arming mode must be configured for “Exit Terminator” for this zone type to function. 2 Single EOL - N/C Use this wiring type for normally closed detection devices. 13 Away Arm Key Use this zone type for a key switch or lock that has switch contacts. This zone type will away arm the assigned areas when active and disarm the assigned areas when healthy. If a “momentary” operation is required then the “Momentary Keyswitch” attribute can be assigned, see page 20. 14 Stay Arm Key Use this zone type for a key switch or door lock that has switch contacts. This zone type will stay arm (1) the assigned areas when active and disarm the assigned areas when healthy. If a “momentary” operation is required then the “Momentary Keyswitch” attribute can be assigned, see page 20. 15 Stay 2 Arm Key This zone type operates as type 14, but performs a stay arm 2. 16 Stay 3 Arm Key This zone type operates as type 14, but performs a stay arm 3. 17 Bypass Key Use this zone type for a key switch or door lock that has switch contacts. This zone type will bypass all zones with the bypass attribute when active and reinstate them when healthy. If a “momentary” operation is required then the “Momentary Keyswitch” attribute can be assigned, see page 20. 18 Security Key Use this zone type for a key switch. This zone type will disable all remote keypads when active and reinstate them when healthy. If a “momentary” operation is required then the “Momentary Keyswitch” attribute can be assigned, see page 20. 19 Auxiliary Use this zone type for auxiliary devices, which do not require an audible alarm response. This zone type generates a silent alarm if activated at any time. 20 Warning Use this zone type for monitoring devices that require a warning indication. This zone type generates a warning (low level beeps from the keypad every 30 seconds and zone indication) if the zone remains active for longer than the warning delay time, see page 24 for details. 21 Log/Monitor Use this zone type for monitoring devices that require an event log entry. This zone type generates a log entry if activated at any time. 22 Trouble/Fault Use this zone type for monitoring fault outputs on devices such as remote power supplies. This zone type generates a fault condition if it is activated at any time. Zone Wiring Each zone must be programmed to the correct wiring type in order for the correct response. Locations: 1201 to 1250 Zone 01 to 50: Zone Wiring. Entry Mode: Mode: Selection List (see page 16). 0 Normally Closed Use this wiring type for normally closed detection devices. 20 3 Double EOL Use this wiring type for detection devices that require both alarm and tamper monitoring. 4 Triple EOL Use this wiring type for detection devices that require alarm, tamper, fault and anti-mask monitoring. Zone Attributes Each zone can have one or more optional attributes programmed to further alter its functionality. Locations: 1301 to 1350 Zone 01 to 50: Zone Attributes. Entry Mode: Bit Toggle Selection (see page 17). 1 Double Knock On: When a zone is enabled for Double Knock it will only cause an alarm when: (a) The zone remains active for the duration of the “Double Knock Delay”. (b) The zone is violated twice within the “Double Knock Delay”. (c) If any two zones with the “Double Knock” attribute are activated during the “Double Knock Time Window”. Off: The zone functions as normal. 2 Enable Comms On: The on-board communicator will report the alarm status to the monitoring station when the zone causes an alarm. Off: The alarm status is not transmitted. 3 Reset On: Zones with this attribute will not be monitored during the detector reset period. The detector reset occurs when the exit mode is started or when the user resets the system after an alarm. Detection devices such as smoke detectors that are powered from an output programmed as “Detector Reset” should have this attribute switched on. Off: The zone functions as normal. 4 Zone Response On: Zones with this attribute respond at the response rate determined by the “Zone Response Timer”. Off: The zone functions as normal. 5 Auto Rearm On: Zones with this attribute will only re-arm at the end of the bell duration providing that the “Auto Re-Arm Counter” limit has not been reached. Once this limit has been reached, the zone will lock out and not cause any further Intruder alarms. Off: The zone will always re-arm. 6 Remote Detector Test On: Zones with this attribute are monitored for specific activity during the remote detector test. The detector must be connected to the control panel using triple EOL wiring and the detector remote test input must be connected to a panel output programmed as “Remote Detector Test”. Off: The zone functions as normal. 7 Momentary Keyswitch On: If the zone type is a keyswitch type, the operation mode is changed to momentary. Off: If the zone type is a keyswitch type, the operation remains as latching mode. P0016-LI-03.01 Zone Areas Zone Chime The EC-P50 has 5 areas which allow the system to be divided into different areas of protection. Each area can be armed and disarmed independently from each other. By default all zones are assigned to area 1, but if required a zone can be assigned to any of the 5 available areas. If a zone is assigned to more than one area it will only be armed when all assigned areas are armed. Each zone can have an optional chime mode programmed that allows the panel and remote keypads to generate an audible tone when the zone is activated in the disarmed mode. Locations: Entry Mode: 1401 to 1450 Zone 01 to 50: Areas. Entry Mode: Bit Toggle Selection (see page 17). Locations: 1601 to 1650 Zone 01 to 50: Zone Chime. Mode: Selection List (see page 16). 0 Off The zone will not generate a chime tone. 1 Area 1 On: The zone is assigned to area 1. Off: The zone is not assigned to area 1. 1 Tone 1 The zone generates chime tone 1 when activated in the disarmed mode. 2 Area 2 On: The zone is assigned to area 2. Off: The zone is not assigned to area 2. 2 Tone 2 The zone generates chime tone 2 when activated in the disarmed mode. 3 Area 3 On: The zone is assigned to area 3. Off: The zone is not assigned to area 3. 3 Tone 3 The zone generates chime tone 3 when activated in the disarmed mode. 4 Area 4 On: The zone is assigned to area 4. Off: The zone is not assigned to area 4. 4 Voice The zone generates a voice response from control panel loudspeaker when activated in the disarmed mode, e.g. “Zone three”. 5 Area 5 On: The zone is assigned to area 5. Off: The zone is not assigned to area 5. Zone Soak Test Zone Bypass Options Each zone can have one or more optional bypass attributes programmed to control when the zone is bypassed. Locations: Locations: 1501 to 1550 Zone 01 to 50: Zone Bypass Options. Entry Mode: Each zone can be put on test for a programmed soak test period. When a zone is on test it will not cause an alarm if activated, but the system will record the failure in the event log and indicate the fault to the user. 1701 to 1750 Zone 01 to 50: Zone Soak Test. Entry Mode: Mode: Selection List (see page 16). Bit Toggle Selection (see page 17). 1 In Stay 1 On: The zone is bypassed when Stay 1 arming mode is selected. Off: The zone is not bypassed when Stay 1 is selected. 2 In Stay 2 On: The zone is bypassed when Stay 2 arming mode is selected. Off: The zone is not bypassed when Stay 2 is selected. 3 In Stay 3 On: The zone is bypassed when Stay 3 arming mode is selected. Off: The zone is not bypassed when Stay 3 is selected. 4 Manual On: The zone can be manually bypassed by the user when arming the system. Off: The zone cannot be bypassed by the user. 0 No The zone is not on soak test. 1 Yes The zone is on soak test. Zone Text Each zone can be assigned a 20 character label that is displayed on LCD remote keypads when viewing the zone status and event log. Locations: 1801 to 1850 Zone 01 to 50: Zone Text. Entry Mode: String Edit - Text Mode (see page 19). Zone Link 5 Auto Bypass On: The zone is automatically bypassed at the end of exit mode if the zone is still active. Off: The zone is not bypassed at the end of exit mode, and the system will fail to arm if the zone remains active. Each zone can be assigned a “Link” number, which in turn is used to control “Link Control” output types, for details on link control, see page 32. 6 Keyswitch Bypass On: The zone is bypassed when a “Bypass Key” zone type is active and reinstated when the “Bypass Key” is secure. Off: The zone is not bypassed when a Bypass Key is operated. Entry Mode: Locations: 1901 to 1950 Zone 01 to 50: Zone Link. Number Entry (see page 18). 7 Cleaner On: The zone is bypassed when a cleaner code is entered. Off: The zone is not bypassed when the cleaner code is entered. P0016-LI-03.01 21 2432 - Area 4 Stay Arm Mode. 2532 - Area 5 Stay Arm Mode. 2. Area Options This section covers programming of the arming modes, timers and options for each of the 5 areas. Entry Mode: Area Timers 0 Final Exit When the exit mode is started, the selected area will only arm after the activation of a Final Exit 1 or Final Exit 2 zone type, e.g., after the front door is opened the closed. Each arming mode has its own set of timers that are used to control various delays during arming, disarming and in alarm. Locations: 2101 to 2107 Area 1: Timers 01 to 07. 2201 to 2207 Area 2: Timers 01 to 07. 2301 to 2307 Area 3: Timers 01 to 07. 2401 to 2407 Area 4: Timers 01 to 07. 2501 to 2507 Area 5: Timers 01 to 07. Entry Mode: Number Entry (see page 18). 01 Exit Delay When the Arming Mode is configured as Timed or deferred, this timer sets the delay between the user initiating the exit procedure and the system actually arming. 02 Entry 1 Delay When the system is armed, activation of a “Final Exit 1” zone will start the entry 1 delay timer, this allows the user time to access the remote keypad and disarm the system. 03 Entry 2 Delay When the system is armed, activation of a “Final Exit 2” zone will start the entry 2 delay timer, this allows the user time to access the remote keypad and disarm the system. 04 Second Entry If at the end of normal entry (Entry 1 or 2) delay, the system has not been disarmed, the system will start the second entry delay, during this time the internal alarm tone will sound. If at the end of the second entry delay the system has still not been disarmed, a full alarm is generated. 05 Bell Delay When an alarm is generated, this timer is used to delay the activation of the external sounder and strobe. 06 Bell Duration When an alarm is generated, this timer is used to control the active duration of the external sounder and strobe. 07 Comms Delay When an alarm is generated, this timer is used to delay the activation of the on-board communicator. Area Arming Modes This set of options control how the selected area is armed for both the “Away” and “Stay” arming mode. Locations: 22 2131 - Area 1 Away Arm Mode. 2231 - Area 2 Away Arm Mode. 2331 - Area 3 Away Arm Mode. 2431 - Area 4 Away Arm Mode. 2531 - Area 5 Away Arm Mode. 2132 - Area 1 Stay Arm Mode. 2232 - Area 2 Stay Arm Mode. 2332 - Area 3 Stay Arm Mode. Bit Toggle Selection (see page 17). 1 Timed Exit When the exit mode is started, the selected area will arm after the Exit Delay timer has expired. 2 Exit Terminator When the exit mode is started, the selected area will only arm after activation of a Final Exit 1 or Final Exit 2 zone type, followed by the activation of an Exit terminator zone, e.g., after the front door is opened the closed and the push to set button has been pressed. 3 Deferred When the exit mode is started, the selected area will arm after the Exit Delay timer has expired. However, if a zone off the exit route is activated during this period, the Exit Delay timer is suspended whilst the zone is active. Area Configuration Options 1 This first set of configuration options controls the operation of each area. Locations: 2141 - Area 1 Configuration Options 1. 2241 - Area 2 Configuration Options 1. 2341 - Area 3 Configuration Options 1. 2441 - Area 4 Configuration Options 1. 2541 - Area 5 Configuration Options 1. Entry Mode: Bit Toggle Selection (see page 17). 1 Arming with AC off On: The selected area can be armed when the mains supply is switched off. Off: The selected area cannot be armed when the mains supply is switched off. 2 Arming with ATS Fault On: The selected area can be armed with an Alarm Transmission Fault (telephone line fault). Off: The selected area cannot be armed when the mains supply is switched off. 3 Auto Stay Arm On: The selected area automatically performs a Stay Arm, if the user does not activate a Final Exit zone. Off: The selected area will always perform an Away Arm. 4 Silent Exit On: The selected area exit tone remains silent during exit mode. Off: The selected area exit tone is generated during exit mode. 5 Local Exit Tone On: If the exit tone is enabled, the exit tone is only generated from the remote keypad that was used arm the selected area. Off: If the exit tone is enabled, the exit tone is generated from all devices assigned to selected area. 6 Anti-Masking when Armed On: Anti-Masking faults are only monitored when the selected area is armed. Off: Anti-Masking faults are monitored at all times for the selected area. P0016-LI-03.01 7 Bell on Arm Fail On: If the selected area fails to arm, the external sounder and strobe is activated. Off: The external sounder and strobe are not activated. 8 Pulse Strobe on Arm On: When the selected area is armed successfully, the external strobe is activated for 5 seconds. Off: The external strobe is not activated. Area Configuration Options 2 This second set of configuration options controls the operation of each area. Locations: Entry Mode: 2142 - Area 1 Configuration Options 2. 2242 - Area 2 Configuration Options 2. 2342 - Area 3 Configuration Options 2. 2442 - Area 4 Configuration Options 2. 2542 - Area 5 Configuration Options 2. Bit Toggle Selection (see page 17). 1 Only Exit when Ready On: The exit mode can only be started if all zones are healthy (System Ready) for the selected area. Off: The exit mode can be started even if one or more zones are active. The active zones will be indicated on the remote keypads and a fault tone is generated. 2 Instant Bell on ATS Fault On: The selected area bell delay is overridden and set to zero, when the Alarm Transmission System (ATS/on-board communicator) fault occurs. Off: The selected area bell delay remains unchanged, when an ATS fault occurs. 3 Alarms are Engineer Reset On: Intruder alarms generated in the selected area require an engineer to reset the system back to normal. Off: Intruder alarms in the selected area can be reset by users. 4 Enable Bell Squawk On: The bell output is pulsed once for a very short period when the selected area is armed and twice when disarmed. Off: The bell output operates as normal for the selected area. 5 Enable Walk Squawk On: The bell output is pulsed once for a very short period when a zone is activated during a walk test in the selected area. Off: The bell output operates as normal for the selected area. 6 Enable Walk Voice On: The zone and number (e.g., “Zone 10”) is announced through the loudspeaker when a zone is activated during a walk test in the selected area. Off: The bell output operates as normal for the selected area. 7 Chime = Link 99 On: The chime feature is automatically turned on and off by Link Control 99. Off: The chime feature must be manually turned on or off by the user. Area Keyswitch Control The set of options controls how the selected area responds when a keyswitch zone is used for arming. Locations: P0016-LI-03.01 2143 - Area 1 Keyswitch Control. 2243 - Area 2 Keyswitch Control. 2343 - Area 3 Keyswitch Control. 2443 - Area 4 Keyswitch Control. 2543 - Area 5 Keyswitch Control. Entry Mode: Bit Toggle Selection (see page 17). 1 Silent Arm On: The exit tone remains silent during exit mode, when a keyswitch is used to arm the selected area. Off: The exit tone is generated during exit mode, when a keyswitch is used to arm the selected area. 2 Disabled when Armed On: The keyswitch is disabled when selected area is armed (arm only keyswitch). Off: The keyswitch remains enabled when the selected area is armed. 3 Instant Arm On: The selected area is armed instantly when a keyswitch is used. Off: The area exit mode is used to arm the selected area. Area Timer Control This set of options controls how the system Control Timers can be used to automatically arm/disarm the selected areas at specific times and on specific days of the week. Please refer to page 26 for details on Control Timer configuration. Locations: 2151 - Area 1 Timer Control. 2251 - Area 2 Timer Control. 2351 - Area 3 Timer Control. 2451 - Area 4 Timer Control. 2551 - Area 5 Timer Control. Entry Mode: Bit Toggle Selection (see page 17). 1 Arm with Control Timer 1 On: The selected area is automatically armed by Control Timer 1. Off: The selected area is not armed automatically. 2 Arm with Control Timer 2 On: The selected area is automatically armed by Control Timer 2. Off: The selected area is not armed automatically. 3 Arm with Control Timer 3 On: The selected area is automatically armed by Control Timer 3. Off: The selected area is not armed automatically. 4 Arm with Control Timer 4 On: The selected area is automatically armed by Control Timer 4. Off: The selected area is not armed automatically. 5 Disarm with Control Timer 1 On: The selected area is automatically disarmed by Control Timer 1. Off: The selected area is not disarmed automatically. 6 Disarm with Control Timer 2 On: The selected area is automatically disarmed by Control Timer 2. Off: The selected area is not disarmed automatically. 7 Disarm with Control Timer 3 On: The selected area is automatically disarmed by Control Timer 3. Off: The selected area is not disarmed automatically. 8 Disarm with Control Timer 4 On: The selected area is automatically disarmed by Control Timer 4. Off: The selected area is not disarmed automatically. 23 3. System Configuration This section covers programming of the system timers, counters, hardware, control timers, banner text, voice options and links. System Timers The system timers control global system timing and delay operation. Locations: Entry Mode: 3101 - AC Fail Delay. 3102 - ATS Fault Delay. 3103 - Zone Response Time. 3104 - Abort Delay. 3105 - Battery Test Period. 3106 - Battery Test Duration. 3107 - Zone Soak Test Time. 3108 - Double Knock Delay. 3109 - Service Interval. 3110 - Confirmation Period. 3111 - Pulse 1 Time. 3112 - Pulse 2 Time. 3113 - Pulse 3 Time. 3114 - Delay 1 Time. 3115 - Delay 2 Time. 3116 - Delay 3 Time. 3117 - Warning Delay. Number Entry (see page 18). 01 AC Fail Delay This timer is used to delay (0-255 minutes) the audible annunciation from the keypads and internal sounders following an AC mains failure. Default = 30 minutes. 02 ATS Fault Delay This timer is used to delay (0-255 minutes) the audible annunciation from the keypads and internal sounders following a ATS fault (telephone line fault). Default = 30 minutes 03 Zone Response Time This timer is used to control the response (0-255 x 10ms) of zones programmed with the “Fast Response” attribute. Default = 750 milliseconds. 04 Abort Delay This timer is used to control abort delay period (0-255 x seconds). When an intruder alarm is generated, this timer is started and if the system is disarmed before the timer expires an “Alarm Abort” event is generated. This event can be signalled to the alarm receiving centre. Default = 180 seconds. 05 Battery Test Period This timer is used to control frequency (0-255 hours) at which the standby battery is load tested. Default = 24 hours. 09 Service Interval This timer controls the frequency (0-255 weeks) in which a “Service Required” event is generated. Default = 0 weeks. 10 Confirmation Period This timer controls the duration (0-255 minutes) in which a confirmed alarm event can be generated. When the system is armed and an intruder alarm is generated (first alarm), this timer is started. If a second, but different zone activates an intruder alarm before the timer expires, a confirmed alarm event is generated. Default = 45 minutes. 11 Pulse 1 Time This timer controls the active duration (0-255 seconds) of outputs programmed with the “Pulse 1” attribute. Default = 10 seconds. 12 Pulse 2 Time This timer controls the active duration (0-255 seconds) of outputs programmed with the “Pulse 2” attribute. Default = 30 seconds. 13 Pulse 3 Time This timer controls the active duration (0-255 minutes) of outputs programmed with both the “Pulse 1” and “Pulse 2” attributes. Default = 10 minutes. 14 Delay 1 Time This timer controls the switch on delay (0-255 seconds) of outputs programmed with the “Delay 1” attribute. Default = 10 seconds. 15 Delay 2 Time This timer controls the switch on delay (0-255 seconds) of outputs programmed with the “Delay 2” attribute. Default = 30 seconds. 16 Delay 3 Time This timer controls the switch on delay (0-255 minutes) of outputs programmed with both the “Delay 1” and “Delay 2” attributes. Default = 10 minutes. 17 Warning Delay This timer controls the delay (0-255 seconds) in which zones programmed as “Warning” must remain active before a warning tone is generated. Default = 60 seconds. System Counters The system counters are used to limit the number of times a function or feature can be carried out. Locations: 3201 - Auto Rearm Counter. 3202 - Number of Remote Resets. 3203 - Count Warning. 3204 - Count Logging. Entry Mode: Number Entry (see page 18). 01 Auto Rearm Counter This counter controls the number of times (0-255) a zone can rearm during an armed period. Once a zone has reached its rearm limit, it is locked out so that it cannot cause further alarm activations during the same armed period. Default = 3. 06 Battery Test Duration This timer is used to control the duration (0-255 seconds) of the standby battery load test. Default = 10 seconds. 02 No of Remote Resets This counter controls the number of times (0-255) the UDL software can be used to reset the system remotely before an engineer must attend site. Default = 0. 07 Zone Soak Test Time This timer is used to control the duration (0-255 days) of the zone soak test. The timer is automatically started after a zone is put on test. Default = 14 days. 03 Count Warning This counter controls the number of times (0-255) that a zone must activate, before triggering the corresponding “Zone ## Count” output. Default = 0. 08 Double Knock Delay This timer controls the duration (0-255 seconds) of the double knock delay. The double knock delay is used to control the operation of zones programmed with “Double Knock” attribute, see page 20. Default = 30 seconds. 02 Count Logging This counter controls the number of times (0-255) that a zone must activate, before logging a “Zone Count ##” event in the system log. Default = 0. 24 P0016-LI-03.01 Hardware - Volume Levels This set of options controls the volume levels for each group of system tones and voice messages. Locations: Entry Mode: 3301 - Panel Speaker Volume. 3302 - Chime Volume. 3303 - Advisory Tone Volume. 3304 - Alarm Tone Volume. Number Entry (see page 18). 4 Battery Presence On: The standby battery is monitored for its presence. Off: The standby battery is not monitored. 5 Mains AC On: The mains supply is monitored for its presence. Off: The mains supply is not monitored. 6 Telephone Line On: The telephone line connection is monitored for faults. Off: The telephone line connection is not monitored. 01 Panel Speaker Volume This option controls the level (0-10) of the exit, entry, fault and warning tones from the control panel speaker. Default = 5. 7 Bell Tamper On: The bell tamper input is monitored for activity. Off: The bell tamper input is not monitored. 02 Chime Volume This option controls the level (0-10) of the chime tone from the control panel speaker. Default = 5. System Configuration 1 03 Advisory Tone Volume This option controls the level (0-10) of the advisory tones from the control panel speaker. Default = 5. Locations: 3401 Entry Mode: Bit Toggle Selection (see page 17). 04 Alarm Tone Volume This option controls the level (0-10) of the alarm tones from the control panel speaker. Default = 10. 1 Auto BST/GMT On: The system clock is automatically put forward by one hour on the last Sunday in March at 2.00AM and put back by one hour on last Sunday in October at 2:00AM. Off: The system clock remains unchanged. Output Monitoring This option enables/disables fault monitoring of the control panel outputs. Locations: 3310 Entry Mode: Bit Toggle Selection (see page 17). 1 Panel Output 1 (Bell) On: The output is monitored for faults. Off: The output is not monitored. 2 Panel Output 2 (Strobe) On: The output is monitored for faults. Off: The output is not monitored. 3 Panel Output 3 On: The output is monitored for faults. Off: The output is not monitored. 4 Panel Output 4 On: The output is monitored for faults. Off: The output is not monitored. 5 Panel Output 5 On: The output is monitored for faults. Off: The output is not monitored. Hardware Monitoring This set of options allows the monitoring of the control panel hardware to be enabled or disabled. Locations: 3311 Entry Mode: Bit Toggle Selection (see page 17). 1 Panel Box Tamper On: The box tamper is monitored for activity. Off: The box tamper is not monitored. This first set of configuration options allow the system operation and features to be altered. 2 Battery Test by Control Timer 5 and Disarm On: The battery test feature is invoked when Control Timer 5 switches on and every time the system is disarmed. Off: The battery test feature is performed by the “Battery Test Period” timer. 3 Reinstate Bypassed Zones on Disarm On: Any zones that have been manually bypassed are automatically reinstated when the system is disarmed. Off: Bypassed zones remain bypassed after the system is disarmed. 4 Enable EN50131-1 Requirements On: The system operates so as to comply with requirements of EN50131-1. Off: The system operates as normal. 5 Disable Bell when Disarmed On: The bell output is disabled when the system is disarmed. Off: The bell output is enabled when the system is disarmed and if a 24hr alarm zone is activated it will trigger the bell output. 6 Disable Communications when Disarmed On: The control panel on-board communicator is disabled when the system is disarmed. Off: The on-board communicator is enabled when the system is disarmed. 7 Tamper Alarms are Engineer Reset On: Tamper alarms require an engineer to reset the system. Off: The user can reset tamper alarms. 8 View Active Zones On: Zone activity is displayed when the system is disarmed. Off: Zone activity is not displayed. 2 Auxiliary Fuse On: The auxiliary 12V fuse is monitored for faults. Off: The auxiliary 12V fuse is not monitored. 3 System Voltage On: The system voltage is monitored for faults. Off: The system voltage is not monitored. P0016-LI-03.01 25 System Configuration 2 Area Labels This second set of configuration options further allow the system operation and features to be altered. This set of options allows you to assign a text label for each area, e.g., “Shop floor” for area 1. The area label can be displayed when the user arms and disarms the system or it can also be displayed when programming zone, keypad, expander and user area options. Locations: 3402 Entry Mode: Bit Toggle Selection (see page 17). 1 Global Keypad Information On: The area and zone status information displayed on the system remote keypads is global, i.e., all keypads show the same information. Off: The area and zone status information displayed on the system remote keypads is local, e.g., if the keypad is assigned to area 3, then only information relating area 3 is displayed. 2 EXP Lost = Zone Tamper On: When a zone expander is disconnected from the network, each programmed zone on the expander generates a tamper response. Off: When a zone expander is disconnected from the network, the system only generates an expander lost response. Locations: 3611 to 3615 Areas 1 to 5: Text Labels. Entry Mode: String Edit - Text Mode (see page 19). Remote Control Labels This set of options allows you to customise the text label that is displayed on LCD keypads for each remote control output. When the user accesses the remote control output menu, the labels are displayed, e.g., “Garden Lights”. Locations: 3621 to 3625 Remote Control 1 to 5: Text Labels. Entry Mode: String Edit - Text Mode (see page 19). Control Timers Voice Options The EC-P50 has five programmable Control Timers, each timer has a switch on time (On Time), switch off time (Off Time) and days of operation for both the On and Off times. Control Timer can be used to automatically arm the system or lock users from accessing the system. The control timer can also be assigned a “Link” number, which in turn is used to control “Link Control” output types, for details on link control, see page 32. Activate by Link Control Locations: 3501 to 3505 Control Timers 1 to 5: On Time. 3511 to 3515 Control Timers 1 to 5: Off Time. Entry Mode: Number Entry (see page 18). Enter time in 24hour format, e.g., 1715 = 05.15 PM. Locations: Locations: 3701 to 3715 Voice Message 01 to 15: Activated by Link. Entry Mode: Number Entry (see page 18). Voice Message Options Control Timers 1 to 5: On Time Days. The voice message options allow you to control how the message is played. Control Timers 1 to 5: Off Time Days. Entry Mode: Bit Toggle Selection (see page 17). Options 1 to 7 = Sunday to Saturday. 3541 to 3545 Control Timers 1 to 5: Link. Entry Mode: The Link Control is the logical output trigger that causes the voice message to be played. The system has 99 “Link Control” outputs, which can be programmed to trigger for a combination of system events, see “Link Control” on page 32. 3521 to 3525 3531 to 3535 Locations: This system has 15 programmable voice messages; each message can be up to 16 seconds long. The messages can be recorded using the Eclipse UDL software and uploaded into the control panel. Alternatively voice messages can be recorded from a telephone handset. Number Entry (see page 18). Banner Text This set of options allows you to customise the text that is displayed on LCD keypads. The “Keypad Banner” is displayed on the top line when the system is disarmed. The “Engineer Reset Banner” is displayed on the bottom line when the system requires an engineer to reset the system. The top line will always show “Call Engineer”. Locations: 3604 - Keypad Banner. 3605 - Engineer Reset Banner. Entry Mode: String Edit - Text Mode (see page 19). Locations: 3801 to 3815 Voice Message 01 to 15: Options. Entry Mode: Bit Toggle Selection (see page 17). 1 Keep Repeating On: The voice message repeats continuously until the associated “Link Control” is no longer active. Off: The voice message plays once. 2 Repeat every 10 Seconds On: The voice message repeats every 10 seconds until the associated “Link Control” is no longer active. Off: The voice message plays once. 3 Repeat every 30 Seconds On: The voice message repeats every 30 seconds until the associated “Link Control” is no longer active. Off: The voice message plays once. 4 Repeat every Minute On: The voice message repeats every minute until the associated “Link Control” is no longer active. Off: The voice message plays once. 5 Repeat every 5 Minutes On: The voice message repeats every 5 minutes until the associated “Link Control” is no longer active. Off: The voice message plays once. 26 P0016-LI-03.01 6 Repeat every 15 Minutes On: The voice message repeats every 15 minutes until the associated “Link Control” is no longer active. Off: The voice message plays once. 7 Repeat every 30 Minutes On: The voice message repeats every 30 minutes until the associated “Link Control” is no longer active. Off: The voice message plays once. 8 Repeat every 60 Minutes On: The voice message repeats every 60 minutes until the associated “Link Control” is no longer active. Off: The voice message plays once. Options 2 to 8 can be added together to create combined timings, e.g., if option 3 and 4 are on the voice message will repeat every 1 minute and 30 seconds. System Links Each system output can be assigned a “Link” number, which in turn is used to control the “Link Control” output types, for details on link control, see page 32. Locations: 3901 to 3950 System Outputs 01 to 50: Link. Entry Mode: Number Entry (see page 18). The table below shows the system output types and their corresponding number 01 to 50. For details of each system output function, please see page 31. System Link Types 01 = AC Fault 06 = System Armed/Alarm 02 = ATS Fault 07 = Bell 03 = System Open 08 = Strobe 04 = System Armed 09 = Intruder Alarm 05 = System Part Armed 10 = Confirmed Alarm 11 = Alarm Abort 16 = Medical Alarm 12 = Fire Alarm 17 = Tamper Alarm 13 = PA Alarm 18 = Ready for Arming 14 = Duress Alarm 19 = Trouble 15 = 24hr Alarm 20 = Alert 21 = Bypass 26 = PSTN Off-Hook 22 = In Walk Test 27 = PSTN Ringing 23 = Flash 1 Second 28 = Battery Fault 24 = User Test Active 29 = Control Panel Box Tamper 25 = PSTN Fault 30 = Bell Tamper 31 = Engineer on Site 36 = Entry Mode 32 = Detector Reset 37 = Second Entry Mode 33 = Switched 12V 38 = General Alarm 34 = System Low Volts 39 = Auxiliary 35 = Exit Mode 40 = Warning 41 = Keypads Locked 46 = Cleaner Bypassed 42 = Output Fault 47 = 2-Wire Smoke 43 = Engineer Reset Required 48 = 2-Wire Smoke Alarm 44 = Device Fault 49 = 2-Wire Smoke Fault 45 = Service Required 50 = Door Access 51 = Alarm Test 52 = Panel AC On 53 = Reset Active 4. Keypad Configuration This section covers programming of the remote keypads. Keypad Options 1 This first set of options controls how the selected keypad onboard keys and tamper function. Locations: 4111 to 4114 Keypads 1 to 4: Options 2. Entry Mode: Bit Toggle Selection (see page 17). 1 Fire Activation from keys 1 and 3 On: Pressing keys 1 and 3 on the selected keypad at the same time will generate a fire alarm event. Off: The selected keypad cannot generate fire alarm events. 2 Medical Activation from keys 4 and 6 On: Pressing keys 4 and 6 on the selected keypad at the same time will generate a medical alarm event. Off: The selected keypad cannot generate medical alarm events. 3 PA Activation from keys 7 and 9 On: Pressing keys 7 and 9 on the selected keypad at the same time will generate a panic alarm (PA) event. Off: The selected keypad cannot generate panic alarm events. 4 Silent Keypad PA On: If option 3 is enabled the selected keypad will generate a silent panic alarm event. Off: If option 3 is enabled the selected keypad will generate an audible panic alarm event. 5 Quick Away Arm Enabled On: The away arm mode can be carried out from the selected keypad by simply pressing key. Off: The user passcode must be entered at the selected keypad before the away arm mode can be selected. 6 Quick Stay Arm Enabled On: The stay arm mode can be carried out from the selected keypad by simply pressing key. Off: The user passcode must be entered at the selected keypad before the stay arm mode can be selected. 7 Quick Bypass Enabled On: The zone bypass feature can be invoked at the selected keypad by simply pressing key. Off: The user passcode must be entered at the selected keypad before the bypass feature can be selected. 8 Keypad Tamper Enabled On: The lid tamper on the selected keypad is monitored. Off: The lid tamper on the selected keypad is not monitored. Keypad Options 2 This second set of options controls how the selected keypad functions when invalid keys are pressed (code tamper). Locations: 4121 to 4126 Keypads 1 to 6: Options 2. Entry Mode: Bit Toggle Selection (see page 17). 1 Enable Code Tamper On: Entering 15 or more invalid key presses on the selected keypad will generate a code tamper event. Off: The selected keypad cannot generate code tamper events. 54 = Arming Failed 55 = Confirm Device P0016-LI-03.01 27 2 Lockout Keypad On: If the “Enable Code Tamper” option is enabled for the selected keypad, the keypad operation will be locked out for 5 minutes if a code tamper event is generated. Off: The selected keypad operation remains unchanged. Keypad Sounds This set of options controls how the selected keypad generates sounds from its on-board sounder. Locations: 4131 to 4136 Keypads 1 to 6: Sounds. Entry Mode: Bit Toggle Selection (see page 17). 1 Alarm Tones On: The selected keypad generates alarm tones. Off: The selected keypad will not generate alarm tones. 1 Area 1 On: The keypad is assigned to area 1. Off: The keypad is not assigned to area 1. 2 Area 2 On: The keypad is assigned to area 2. Off: The keypad is not assigned to area 2. 3 Area 3 On: The keypad is assigned to area 3. Off: The keypad is not assigned to area 3. 4 Area 4 On: The keypad is assigned to area 4. Off: The keypad is not assigned to area 4. 5 Area 5 On: The keypad is assigned to area 5. Off: The keypad is not assigned to area 5. 2 Trouble Tones On: The selected keypad generates trouble tones. Off: The selected keypad will not generate trouble tones. 3 Chime Tones On: The selected keypad generates chime tones. Off: The selected keypad will not generate chime tones. 4 Entry Tones On: The selected keypad generates entry tones. Off: The selected keypad will not generate entry tones. 5 Exit Tones On: The selected keypad generates exit tones. Off: The selected keypad will not generate exit tones. 6 Key Press Tones On: The selected keypad generates key press tones. Off: The selected keypad generates a short click tone when keys are pressed. 7 Advisory Tones On: The selected keypad generates advisory tones. Off: The selected keypad will not generate advisory tones. 8 Tamper Tones On: The selected keypad generates tamper alarm tones. Off: The selected keypad will not generate tamper alarm tones. Keypad Areas Keypads must be assigned to one or more areas to ensure correct operation of the system. The keypad areas control the following: f When the system is exit mode only the keypads in the areas that are being armed will generate the exit tone. f When arming one or more areas from a keypad, only the arming modes for the area(s) that are assigned to keypad are applied. The areas that are not assigned are armed instantly. For example, if the keypad is assigned to area 2, and a user request to arm all areas (1-5), areas 1, 3, 4 and 5 arm instantly and the exit mode for area 2 is applied e.g. 30 seconds exit delay. f When using a “Local Standard” user only the areas assigned to keypad can be armed and disarmed. f When a lid tamper is activated from the keypad, the tamper alarm is generated for the area(s) assigned to keypad. Locations: 4141 to 4146 Keypads 1 to 6: Areas. Entry Mode: 28 Bit Toggle Selection (see page 17). P0016-LI-03.01 5. Expander Configuration This section covers programming of the expander modules. Expander Areas Expanders must be assigned to one or more areas to ensure correct operation of the system. The expander areas control the following: 2 Trouble Tones On: The selected expander generates trouble tones. Off: The selected expander will not generate trouble tones. 3 Chime Tones On: The selected expander generates chime tones. Off: The selected expander will not generate chime tones. f When the system is exit mode only the expander in the areas that are being armed will generate the exit tone. 4 Entry Tones On: The selected expander generates entry tones. Off: The selected expander will not generate entry tones. f When a lid tamper is activated from the expander, the tamper alarm is generated for the area(s) assigned to expander. 5 Exit Tones On: The selected expander generates exit tones. Off: The selected expander will not generate exit tones. Locations: 5101 to 5104 Expander 1 to 4: Areas. Entry Mode: Bit Toggle Selection (see page 17). 1 Area 1 On: The expander is assigned to area 1. Off: The expander is not assigned to area 1. 2 Area 2 On: The expander is assigned to area 2. Off: The expander is not assigned to area 2. 6 Key Press Tones On: Not supported on the expander. Off: Not supported on the expander. 7 Advisory Tones On: The selected expander generates advisory tones. Off: The selected expander will not generate advisory tones. 8 Tamper Tones On: The selected expander generates tamper alarm tones. Off: The selected expander will not generate tamper alarm tones. Expander Outputs 3 Area 3 On: The expander is assigned to area 3. Off: The expander is not assigned to area 3. Both EC-EX10 and EC-EX10/O have 10 programmable outputs. This set of options allows the output type (function) to be assigned to each of the expander outputs. 4 Area 4 On: The expander is assigned to area 4. Off: The expander is not assigned to area 4. Locations: 5201 to 5210 Expander 1: Output 1 to 10 Type. 5211 to 5220 Expander 2: Output 1 to 10 Type. 5 Area 5 On: The expander is assigned to area 5. Off: The expander is not assigned to area 5. 5221 to 5230 Expander Options 5231 to 5240 This set of options controls how the selected expander tamper and internal piezo sounder function. Locations: Expander 4: Output 1 to 10 Type. Entry Mode: Selection List (see page 16). 5111 to 5114 Expanders 1 to 4: Options. Entry Mode: Expander 3: Output 1 to 10 Type. Bit Toggle Selection (see page 17). Enter the two digit group number followed by the two digit type number, e.g., 0301 = “Zone 01 Alarm”. See page 31 for a complete list of output functions. 1 Enable Tamper On: The lid tamper on the selected expander is monitored. Off: The lid tamper on the selected expander is not monitored. Expander Output Attributes 2 Enable Piezo On: The internal piezo sounder on the selected expander is enabled. Off: The internal piezo sounder on the selected expander is disabled. Locations: This set of options allows the output attributes to be assigned to each of the expander outputs. Expander 1: Output 1 to 10 attributes. 5311 to 5320 Expander 2: Output 1 to 10 attributes. 5321 to 5330 Expander Sounds Expander 3: Output 1 to 10 attributes. This set of options controls how the selected expander generates sounds from its onboard piezo sounder and loudspeaker output. Locations: Entry Mode: 5331 to 5340 Expander 4: Output 1 to 10 attributes. 5121 to 5124 Expanders 1 to 4: Sounds. Bit Toggle Selection (see page 17). 5301 to 5310 Entry Mode: Bit Toggle Selection (see page 17). See page 30 for details on output attributes. 1 Alarm Tones On: The selected expander generates alarm tones. Off: The selected expander will not generate alarm tones. P0016-LI-03.01 29 Expander Output Areas This set of options allows the output areas to be assigned to each of the expander outputs. Locations: 5401 to 5410 Expander 1: Output 1 to 10 areas. 5411 to 5420 Expander 2: Output 1 to 10 areas. 5421 to 5430 Expander 3: Output 1 to 10 areas. 5431 to 5440 Expander 4: Output 1 to 10 areas. Entry Mode: Bit Toggle Selection (see page 17). 6. Panel Outputs and Devices This section covers programming of the control panel outputs, communication ports and other devices that maybe connected to the control panel. Panel Output Type This set of options allows the output type (function) to be assigned to the control panel high current outputs. Locations: 6111 to 6115 Panel Outputs 1 to 5: Output Type. Entry Mode: Selection List (see page 16). Enter the two digit group number followed by the two digit type number, e.g., 3001 = “Zone 01 Alarm”. 1 Area 1 On: The expander output is assigned to area 1. Off: The expander output is not assigned to area 1. Panel Output Attributes 2 Area 2 On: The expander output is assigned to area 2. Off: The expander output is not assigned to area 2. Locations: 3 Area 3 On: The expander output is assigned to area 3. Off: The expander output is not assigned to area 3. 4 Area 4 On: The expander output is assigned to area 4. Off: The expander output is not assigned to area 4. 5 Area 5 On: The expander output is assigned to area 5. Off: The expander output is not assigned to area 5. This set of options allows the output attributes to be assigned to the control panel high current outputs. 6121 to 6125 Panel Outputs 1 to 5: Output Attributes. Entry Mode: Bit Toggle Selection (see page 17). 1 Latching On: The selected output latches on when triggered and is only cleared when the user resets the system. Off: The selected output responds normally. 2 Inverted On: The selected output is inverted, off when active and on when inactive. Off: The selected output responds normally. 3 User Test On: The selected output is activated when the user output test is selected. Off: The selected output remains unchanged during the user output test. 4 Pulse 1 On: The selected output activates for the duration of the “Pulse 1 Time” system timer, see page 24. Off: The selected output responds normally. 5 Pulse 2 On: The selected output activates for the duration of the “Pulse 2 Time” system timer, see page 24. Off: The selected output responds normally. 6 Delay 1 On: The selected output activates after the delay set by the “Delay 1 Time” system timer, see page 24. Off: The selected output responds normally. 7 Delay 2 On: The selected output activates after the delay set by the “Delay 2 Time” system timer, see page 24. Off: The selected output responds normally. 8 Armed Only On: The selected output only activates if the system is armed. Off: The selected output responds normally. If “Pulse 1” and “Pulse 2” options are enabled then the selected output activates for the duration of the “Pulse 3 Time” system timer, see page 24. If “Delay 1” and “Delay 2” options are enabled then the selected output activates after the delay set by the “Delay 3 Time” system timer, see page 24. 30 P0016-LI-03.01 Panel Output Areas This set of options allows the output areas to be assigned to each of the control panel high current outputs. Locations: No Type & Description 0002 ATS Fault This output type activates when the on-board communicator detects a phone line fault (Alarm Transmission Fault). 0003 Unset This output type activates when the system is in the disarmed state. 0004 Armed This output type activates when the system is armed in any of the armed modes (Away or Stay) 0005 Part Armed This output type activates when the system is armed in any of the Stay armed modes. 0006 Armed/Alarm This output type activates when the system is armed and pulses when an alarm is generated. 0007 Bell Active This output type activates when an alarm is generated (it may be delayed if the bell delay time is greater than zero). The duration of this output type is controlled by the “Bell Duration” timer. 0008 Strobe Active This output type activates when an alarm is generated and deactivates when the system is reset 0009 Alarm This output type activates when an intruder alarm is generated. 0010 Confirmed Alarm This output type activates when two different zones cause an intruder alarm. 0011 Alarm Abort This output type activates when the user disarms the system after an alarm and within the “Abort Delay” period. 6131 to 6135 Panel Outputs 1 to 5: Output Areas. Entry Mode: Bit Toggle Selection (see page 17). 1 Area 1 On: The panel output is assigned to area 1. Off: The panel output is not assigned to area 1. 2 Area 2 On: The panel output is assigned to area 2. Off: The panel output is not assigned to area 2. 3 Area 3 On: The panel output is assigned to area 3. Off: The panel output is not assigned to area 3. 4 Area 4 On: The panel output is assigned to area 4. Off: The panel output is not assigned to area 4. 5 Area 5 On: The panel output is assigned to area 5. Off: The panel output is not assigned to area 5. Output Types The output types are grouped together in the following groups: Group Description 00 Global Global system output function. 01 Reserved Not available on the EC-P50. 0012 Fire Alarm This output type activates when a fire alarm is generated. 02 Control Timer Control Timers 1 to 5. 0013 PA Alarm This output type activates when a panic alarm is generated. 03 Remote Control Remote control outputs 1 to 5. 0014 Duress Alarm This output type activates when a duress alarm is generated. 04 Link Control Input linked logical conditioned outputs. 0015 24hr Alarm This output type activates when a 24hr alarm is generated. 10 Zone Count Zones 1 to 50 count outputs. 0016 20 Zone Mimic Zones 1 to 50 mimic outputs. Medical Alarm This output type activates when a medical alarm is generated. 0017 30 Zone Alarm Zones 1 to 50 alarm outputs. Tamper Alarm This output type activates when a tamper alarm is generated. 40 Zone Tamper Zones 1 to 50 tamper alarm outputs. 0018 Ready This output type activates when the system is ready for arming, i.e. all zones are healthy. 50 Zone Masked Zones 1 to 50 masked outputs. 0019 60 Zone Fault Zones 1 to 50 fault outputs. Trouble This output type activates when a trouble alarm is generated. 0020 70 Zone Bypassed Zones 1 to 50 bypassed outputs. Alert This output type activates when an alert event is generated and deactivates when the user has acknowledged the alert. 80 User Access Users 00 to 50 access outputs. 0021 Zone Bypass This output type activates when one or more zones are bypassed. 0022 In Walk Test This output type activates when the user walk test mode is selected. 0023 Flash 1 Second This output type continually pulses on and off at a rate of 1 second. 0024 User Test Active This output type activates when the user test mode is selected in the “Bell Test” menu. 00: Global The table below list the output function available in this group: No Type & Description 0000 Not Used This output type does not activate. 0001 AC Fault This output type activates when the mains supply has been removed for the duration of the AC Fail timer. P0016-LI-03.01 31 No Type & Description No Type & Description 0025 PSTN Fault This output type activates when a fault is detected on the PSTN connected to the control panel. 0049 2-Wire Smoke Fault This output type activates when a 2-Wire smoke fault is generated. 0026 PSTN Off Hook This output type activates when an off-hook condition is detected on the PSTN connected to the control panel. 0050 Door Access This output type activates for 30 seconds when any valid user code is entered. 0027 PSTN Ringing This output type activates when ringing is detected on the PSTN connected to the control panel. 0051 Alarm Test This output type activates when the user select the alarm sounder test. 0028 Battery Fault This output type activates when a fault is detected with the control panel standby battery. 0052 Panel AC On This output type activates when the mains supply is present. 0053 0029 Box Tamper Fault This output type activates when the control panel box tamper is open. Reset Active This output type activates for 10 seconds after a user resets the system. 0054 0030 Bell Tamper Fault This output type activates when the control panel bell tamper is open. Arming Failed This output type activates when the system fails to arm. 0055 Confirm Device This output type activates when the number of devices on the network differ to the number confirmed by the engineer. 0056 Stay Arm 1 This output type activates when the system is armed in the Stay 1 mode. 0057 Stay Arm 2 This output type activates when the system is armed in the Stay 2 mode. 0058 Stay Arm 3 This output type activates when the system is armed in the Stay 3 mode. 0031 Engineer on Site This output type activates when the engineer is logged on. 0032 Detector Reset This output type is normally active and is used for powering devices that require their power supply to be removed in order to reset them. The output deactivates for 5 seconds at the start of exit mode and when the system is reset. 0033 Detector Latch This output type is used to latch the alarm condition on detection devices that have a latch input. 0034 System Low Volts This output type activates when a low voltage fault is detected with the control panel standby battery. 0035 In Exit This output type activates when the system is in exit mode. 0036 In Entry This output type activates when the system is in entry mode. 0037 In Second Entry This output type activates when the system is in second entry mode. 0038 In Alarm This output type activates when any alarm is generated. 0039 Auxiliary Alarm This output type activates when an auxiliary alarm is generated. 0040 Warning Alarm This output type activates when a warning alarm is generated. 0041 Keypads Locked This output type activates when a security key is active. 0042 Output Fault This output type activates when a fault is detected on one of the monitored control panel outputs. 0043 Call Engineer This output type activates when the system requires an engineer access code in order to reset the system. 0044 Device Fault This output type activates when a device fault is detected. 0045 Service Required This output type activates when the service timer expires. 0046 Cleaner Bypassed This output type activates when a “Cleaner Bypass” is invoked. 0047 2-Wire Smoke This output type is specifically designed for use with “Panel Output 5”, when connecting 2-Wire Smoke Sensors. 0048 2-Wire Smoke Alarm This output type activates when a 2-Wire smoke alarm is generated. 32 Group 02: Control Timer The EC-P50 has 5 control timers each timer can be assigned to an output: No Type & Description 0201 Control Timer 1 This output type activates when Control Timer 1 is on and deactivates when Control Timer 1 is off. 02020205 Control Timer 2 - 5 As Control Timer 1. Group 03: Remote Control There are 5 remote controlled outputs, which can be assigned to an output: No Type & Description 0301 Remote Control 1 This output type is switched on and off via the UDL software, smart phone app and via a touch tone telephone. 03020305 Remote Control 2 - 5 As Remote Control 1. Group 04: Link Control There are 99 Link controlled outputs, which can be assigned to an output: No Type & Description 0401 Link Control 01 This output type is controlled by a combination of linked inputs. 04020499 Link Control 02 - 99 As Link Control 01. P0016-LI-03.01 To create a link controlled output you must assign link inputs to the Link Control. The available inputs are: f Zone Links f Control Timer Links f Voice Message Links f System Links f User Link Link Control Example 3 In this example we will setup “Link Control 03” so that it activates when zone 10 “AND” Control Timer 1 is on “OR” when the system is in exit mode “OR” when an intruder alarm occurs. The figure below show the logic diagram for this: Logic “1” The inputs can be assigned to the Link Control to perform either a logical “OR” function or a logical “AND” function. The logic function is controlled by the link input number: Logic “1” 001 - 099: Logical “OR” Link inputs. Logic “1” 101 - 199: Logical “AND” Link inputs. Link Control Example 1 In the first example we will setup “Link Control 01” so that it activates when zone 1 “OR” zone 2 “OR” zone 3 is active “OR” user 02 is entered. The figure below show the logic diagram for this: Ê Logic “1” Link Control 01 Link Control 03 Í The four switches represent the link inputs and programmed as follows: Location 1910: Zone 10 Link = 103 (Link Control 03 “AND”). Location 3541: Control Timer 1 Link = 103 (Link Control 03 “AND”). As the figure above shows the Link Control 03 will be active (logic 1) only when link input 1 and 2 are closed (active) or when either link inputs 3 and 4 are closed (active). Group 10: Zone Count The zone activity count threshold of each zone can be assigned to an output: Í Logic “1” Ì Location 3909: System Intruder Alarm Link = 003 (Link Control 03 “OR”). Ì Logic “1” Ë Location 3935: System Exit Link = 003 (Link Control 03 “OR”). Ë Logic “1” Ê The four switches represent the link inputs and programmed as follows: Location 1901: Zone 01 Link = 001 (Link Control 01 “OR”). Location 1902: Zone 02 Link = 001 (Link Control 01 “OR”). Location 1903: Zone 03 Link = 001 (Link Control 01 “OR”). Location 8502: User 02 Link = 001 (Link Control 01 “OR”). As the figure above shows the Link Control 01 will be active (logic 1) when any of the input links are closed (active). Now that Link Control 01 is configured it can be assigned to a panel output or voice message trigger. Link Control Example 2 In this example we will setup “Link Control 02” so that it activates when zone 4 “AND” zone 5 are active “AND” when the system is armed. The figure below shows the logic diagram for this: No Type & Description 1001 Zone 01 Count This output type activates when zone 01 activity count reaches the threshold set by the “Zone Warning” counter. See page 24. 10021050 Zone 02 - 50 Count As Zone 01 Count. Group 20: Zone Mimic The mimic condition of each zone can be assigned to an output: No Type & Description 2001 Zone 01 Mimic This output type activates when zone 01 is active and deactivates when zone 01 is healthy. 20022050 Zone 02 - 50 Mimic As Zone 01 Mimic. Group 30: Zone Alarm Logic “1” Ê Ë The alarm condition of each zone can be assigned to an output: Ì Link Control 02 The three switches represent the link inputs and are programmed as follows: Location 1904: Zone 04 Link = 102 (Link Control 02 “AND”). Location 1905: Zone 05 Link = 102 (Link Control 02 “AND”). No Type & Description 3001 Zone 01 Alarm This output type activates when zone 01 generates an alarm and deactivates when the alarm is reset. 30023050 Zone 02 - 50 Alarm As Zone 01 Alarm. Location 3904: System Armed Link = 102 (Link Control 02 “AND”). As the figure above shows, the Link Control 02 will be active (logic 1) only when ALL of the input links are closed (active). P0016-LI-03.01 33 Group 40: Zone Tamper Communication Ports The tamper condition of each zone can be assigned to an output: These two options allow the operating mode for the two on-board communication ports to be configured. No Type & Description 4001 Zone 01 Tamper This output type activates when zone 01 generates a tamper alarm and deactivates when the alarm is reset. 40024050 Zone 02 - 50 Tamper As Zone 01 Tamper. Group 50: Zone Masked The mask condition of each zone can be assigned to an output: No Type & Description 5001 Zone 01 Masked This output type activates when zone 01 generates a mask fault and deactivates when the fault is cleared and reset. 50025050 Zone 02 - 50 Masked As Zone 01 Masked. Group 60: Zone Fault The fault condition of each zone can be assigned to an output: No Type & Description 6001 Zone 01 Fault This output type activates when zone 01 generates a fault and deactivates when the fault is cleared and reset. 60026050 Zone 02 - 50 Fault As Zone 01 Fault. Group 70: Zone Bypassed The bypass condition of each zone can be assigned to an output: Locations: 6201 - Com Port 1: Mode. 6202 - Com Port 2: Mode. Entry Mode: Selection List (see page 16). 0 UDL USB-Link This mode configures the selected communication port for UDL USB-Link operation. The USB-Link should be connected to the computer and the other end should be connected to the selected control panel communication port. 1 Printer This mode configures the selected communication port for printer operation. Use this mode when using a terminal program via the USB-Link to capture the printer output from the control panel. 2 3rd Party Module This mode configures the selected communication port for a 3rd Party Module operation. Use this mode when connecting a supported 3rd party communication module to the control panel. 3 Communication Module This mode configures the selected communication port for Communication Module operation. Use this mode when connecting any Eclipse communication module to the control panel. 4 Contact ID This mode configures the selected communication port for Contact ID operation. In this mode the Contact ID in ASCII format is sent to the port. No Type & Description 7001 Zone 01 Bypassed This output type activates when zone 01 is bypassed and deactivates when the zone is reinstated. 5 Debug USB-Link This mode configures the selected communication port for data debug operation. Use this mode when using a terminal program via the USB-Link to capture the debug data from the control panel. 70027050 Zone 02 - 50 Bypassed As Zone 01 Bypassed. GSM & SMS Centre Group 80: User Access The system access of each user can be assigned to an output: No Type & Description 8000 User 00 Access This output type activates for 30 seconds after user 00 has entered their access code. 80018050 User 01 - 50 Access As User 00 Access. These options allow the GSM and SMS Centre to be configured. Locations: 6301 - GPRS APN Name 6302 - GPRS APN User 6303 - GPRS APN Password 6304 - SIM Pin 6302 - SIM Credit Code 6311 - SMS Service Centre Entry Mode: String Edit - Number Mode (see page 18). GPRS APN Name The Access Point Name (APN) used by the GSM network operator for IP packet data communication. GPRS APN User The APN user name used to log into the APN. GPRS APN Password The APN password name used to log into the APN. 34 P0016-LI-03.01 Listed below are the GPRS setting used by the major UK GSM network operators: Operator APN User Password Vodafone internet web web Orange Orangeinternet * * O2 Mobile.o2.co.uk web web T-Mobile General.t-mobile.uk * Three 3internet * IP Configuration These options allow the IP details to be configured and are required when using the EC-COM/IP module. Locations: 6401 - IP Address 6402 - Subnet Mask 6403 - Gateway Address 6404 - Port Number * Entry Mode: String Edit - Number Mode (see page 18). * IP Address A valid IP address must be assigned to the module. It must be entered in dot-decimal notation, e.g. “192.168.0.58”. Enter B3 to insert a “.”. * = Leave blank. SIM Pin If the SIM is protected by a PIN, then the number must be entered in this location in order for correct operation. SIM Credit Code If the GSM network operator supports credit balance via USSD, then enter the USSD code, e.g., *123#. SMS Service Centre Number The system can send SMS messages to mobile telephones via the standard PSTN telephone network. To achieve this, it uses the ETSI ES 201 912 protocol 1. This protocol is not supported worldwide so please check with your telephone provider. Listed below are the SMS Centre numbers for supported countries and operators: Country Operator SMS Centre Number UK BT 17094009 Ireland Eirecom 17409900 Germany T-Com 0193010 Belgium Belgacom 14974800 France France Telecom 0809101000 Switzerland Swisscom 0622100000 Netherlands KPN Telecom 0673644444 South Africa Telkom 1091969 Subnet Mask The subnet mask used on the network must be assigned to the module. It must be entered in dot-decimal notation, e.g. “255.255.255.0”. Enter B3 to insert a “.”. Gateway Address The gateway address (normally the ADSL router) used on the network must be assigned to the module. It must be entered in dot-decimal notation, e.g. “192.168.0.1”. Enter B3 to insert a “.”. Port Number A valid port number must be assigned to the module. It must be entered as a decimal number, e.g. “8888”. Caller Line Identity must be enabled in order for the SMS Service Centre to accept the message. P0016-LI-03.01 35 7. On-board Communicator This section covers programming of the on-board communicator. ARC 1-4: Telephone Number This set of options allows the telephone number to be programmed for each ARC. Locations: 7001 to 7004 ARC 1 to 4: Telephone Number. Entry Mode: String Edit - Number Mode (see page 18). Whilst programming telephone numbers, addition characters can be inserted to perform the following: 1 Switch to Next ARC on failed Attempt On: The on-board communicator switches to the next ARC in the sequence, if the current ARC attempt fails. Off: The on-board communicator continues dialling the selected ARC until all its attempts have been used. 2 Use PSTN Pre-Dial On: The on-board communicator dials the “PSTN Pre-Dial Number” before dialling the ARC telephone number. This is normally required when using an internal telephone system. See “PSTN Pre-Dial Number” on page 37. Off: The on-board communicator only dials the ARC telephone number. ARC 1-4: Call Sequence/Attempts B1: Insert a “P” for a 1 second pause. This set of options allows the call sequence to be programmed for each ARC. B2: Insert a “F” to force blind dialling (no dial-tone detection). Locations: 7041 to 7044 Entry Mode: String Edit - Number Mode (see page 18). ARC 1-4: Account Number This set of options allows the account number to be programmed for each ARC. Locations: 7011 to 7014 ARC 1 to 4: Account Number. Entry Mode: String Edit - Number Mode (see page 18). ARC 1 to 4: Call Sequence/Attempts. The call sequence is entered as a string of digits; each number indicates the calling method: 1= PSTN (On-board Communicator) 2 = GSM Module ARC 1-4: Protocol 3 = IP Module This set of options allows the protocol type to be programmed for each ARC. The call attempts are controlled by how many digits are entered. Here are some typical examples: Locations: “111” = Attempt to call the selected ARC three times using the PSTN. 7021 to 7024 ARC 1 to 4: Protocol. Entry Mode: Selection List (see page 16). “1212” = Attempt to call the selected ARC four times alternating between PSTN and GSM. 0 Disabled The selected ARC is disabled. “123” = Attempt to call the selected ARC three times using PSTN, then GSM and finally IP. 1 Contact ID The selected ARC is configured for Contact ID protocol. When triggered, the on-board communicator will dial the telephone number and attempt to communicate with the alarm receiver using Contact ID protocol. “31” = Attempt to call the selected ARC twice, first using IP then PSTN. 2 Fast Format The selected ARC is configured for Fast Format protocol. When triggered, the on-board communicator will dial the telephone number and attempt to communicate with the alarm receiver using standard Fast Format protocol. The control panel supports 16 Fast Format channels, see “Fast Format” on page 38. 3 Voice Format The selected ARC is configured for Voice protocol. When triggered, the on-board communicator will dial the telephone number and play a fixed voice message relating to alarm event. 4 SMS Text The selected ARC is configured for SMS protocol. When triggered, the on-board communicator will dial the SMS Centre and send a SMS text message to the telephone number programmed in the ARC. See page 34 for programming the SMS Centre number. ARC 1-4: Protocol Options This set of options allows the protocol options to be programmed for each ARC. Locations: 7031 to 7034 ARC 1 to 4: Protocol Options. Entry Mode: 36 Bit Toggle Selection (see page 17). ARC 1-4: Reported Event Groups This set of options allows you to control which group of events that are reported for each ARC. Locations: 7051 to 7054 ARC 1 to 4: Reported Event Groups. Entry Mode: Bit Toggle Selection (see page 17). 1 Alarms On: The selected ARC reports events that are assigned in the alarm group. Off: The selected ARC does not report alarm events. 2 Tampers On: The selected ARC reports events that are assigned in the tamper group. Off: The selected ARC does not report tamper events. 3 Faults On: The selected ARC reports events that are assigned in the fault group. Off: The selected ARC does not report fault events. 4 Open/Close On: The selected ARC reports events that are assigned in the open/close group. Off: The selected ARC does not report open/close events. P0016-LI-03.01 5 Test/Misc. On: The selected ARC reports events that are assigned in the test/misc. group. Off: The selected ARC does not report test/misc. events. 6 Restore On: The selected ARC reports events that are assigned in the restore group. Off: The selected ARC does not report restore events. 5 Area 5 On: Events that occur in area 5 are reported to ARC. Off: Events that occur in area 5 are not reported. ARC 1-4: IP Address This option allows an IP address to be programmed for each ARC. Locations: 7081 to 7084 ARC 1 to 4: IP Address. 7 Custom On: The selected ARC reports events that are assigned in the custom group. Off: The selected ARC does not report custom events. Entry Mode: ARC 1-4: Cancel on Success B3: Insert a “.”. This set of options allows you to control communication sequence for each ARC. When the on-board communicator is triggered by an event it will call the ARC using the settings defined in ARC 1. If the communication attempt is successful, this option can be used to either cancel attempts for the remaining available ARC’s or move on and call the next available ARC. ARC 1-4: IP Port Number Locations: 7061 to 7064 ARC 1 to 4: Cancel on Success. Entry Mode: Bit Toggle Selection (see page 17). 1 Stop ARC 1 On: The selected ARC will cancel further attempts to ARC 1 after a successful communication. Off: The selected ARC will move on to next ARC after a successful communication. 2 Stop ARC 2 On: The selected ARC will cancel further attempts to ARC 2 after a successful communication. Off: The selected ARC will move on to next ARC after a successful communication. 3 Stop ARC 3 On: The selected ARC will cancel further attempts to ARC 3 after a successful communication. Off: The selected ARC will move on to next ARC after a successful communication. String Edit - Number Mode (see page 18). Whilst programming IP address, addition characters can be inserted: This option allows an IP port number to be programmed for each ARC. Locations: 7091 to 7094 ARC 1 to 4: IP Port Number. Entry Mode: String Edit - Number Mode (see page 18). Options: Auto Test Call Period The on-board communicator can be programmed to send a test call event to the ARC. This option controls the period in hours in which a test call is sent. The test call timer is reset every time a system event is successfully communicated, therefore a test call will only be sent once the timer reaches zero. Location: 7101 Entry Mode: Number Entry (see page 18). Options: Auto Test Call Time This option allows you to program a time at which the on-board communicator sends a test call. Location: 7102 Entry Mode: Number Entry (see page 18). The time must be entered in a 24hr format, e.g., 2100 = 9:00PM. 4 Stop ARC 4 On: The selected ARC will cancel further attempts to ARC 4 after a successful communication. Off: The selected ARC will move on to next ARC after a successful communication. To disable this feature program the time as 0000. ARC 1-4: Areas Location: This option controls which areas report events to the ARC. Entry Mode: Bit Toggle Selection (see page 17). Options 1 to 7 = Sunday to Saturday. Locations: 7071 to 7074 ARC 1 to 4: Areas. Entry Mode: Bit Toggle Selection (see page 17). 1 Area 1 On: Events that occur in area 1 are reported to ARC. Off: Events that occur in area 1 are not reported. 2 Area 2 On: Events that occur in area 2 are reported to ARC. Off: Events that occur in area 2 are not reported. Options: Auto Test Days This option allows you to select which days of the week the onboard communicator sends a test call. 7103 Options: PSTN Pre-Dial Number This option allows a PSTN pre-dial number (up to 3 digits) to be programmed. Most internal telephone systems require a digit to be dialled before an outside line and dial tone is made available. If this feature is required, make sure that the “Use PSTN Pre-Dial” option is enabled for the required ARC, see “Protocol Options” on page 36. Location: 7104 Entry Mode: String Edit - Number Mode (see page 18). 3 Area 3 On: Events that occur in area 3 are reported to ARC. Off: Events that occur in area 3 are not reported. 4 Area 4 On: Events that occur in area 4 are reported to ARC. Off: Events that occur in area 4 are not reported. P0016-LI-03.01 37 Fast Format: Reporting Channels When the ARC protocol is programmed as Fast Format, the channels that are used for reporting must be enabled or disabled. Locations: 7201 - Reporting Channels 1 – 8. 7241 - Reporting Channels 9 – 16. Entry Mode: Bit Toggle Selection (see page 17). 1 Report Channel 1/9 On: For location 7201 channel 1 is enabled, for location 7241 channel 9 is enabled. Off: For location 7201 channel 1 is disabled, for location 7241 channel 9 is disabled. 2 Report Channel 2/10 On: For location 7201 channel 2 is enabled, for location 7241 channel 10 is enabled. Off: For location 7201 channel 2 is disabled, for location 7241 channel 10 is disabled. 3 Report Channel 3/11 On: For location 7201 channel 3 is enabled, for location 7241 channel 11 is enabled. Off: For location 7201 channel 3 is disabled, for location 7241 channel 11 is disabled. 4 Report Channel 4/12 On: For location 7201 channel 4 is enabled, for location 7241 channel 12 is enabled. Off: For location 7201 channel 4 is disabled, for location 7241 channel 12 is disabled. 5 Report Channel 5/13 On: For location 7201 channel 5 is enabled, for location 7241 channel 13 is enabled. Off: For location 7201 channel 5 is disabled, for location 7241 channel 13 is disabled. 6 Report Channel 6/14 On: For location 7201 channel 6 is enabled, for location 7241 channel 14 is enabled. Off: For location 7201 channel 6 is disabled, for location 7241 channel 14 is disabled. 7 Report Channel 7/15 On: For location 7201 channel 7 is enabled, for location 7241 channel 15 is enabled. Off: For location 7201 channel 7 is disabled, for location 7241 channel 15 is disabled. 8 Report Channel 8/16 On: For location 7201 channel 8 is enabled, for location 7241 channel 16 is enabled. Off: For location 7201 channel 8 is disabled, for location 7241 channel 16 is disabled. Fast Format: Restore Channels When the ARC protocol is programmed as Fast Format, the channels that report a restore event can be enabled or disabled. Locations: 7202 - Restore Channels 1 – 8. 7242 - Restore Channels 9 – 16. Entry Mode: Bit Toggle Selection (see page 17). Off: For location 7202 channel 2 is disabled, for location 7242 channel 10 is disabled. 3 Restore Channel 3/11 On: For location 7202 channel 3 is enabled, for location 7242 channel 11 is enabled. Off: For location 7202 channel 3 is disabled, for location 7242 channel 11 is disabled. 4 Restore Channel 4/12 On: For location 7202 channel 4 is enabled, for location 7242 channel 12 is enabled. Off: For location 7202 channel 4 is disabled, for location 7242 channel 12 is disabled. 5 Restore Channel 5/13 On: For location 7202 channel 5 is enabled, for location 7242 channel 13 is enabled. Off: For location 7202 channel 5 is disabled, for location 7242 channel 13 is disabled. 6 Restore Channel 6/14 On: For location 7202 channel 6 is enabled, for location 7242 channel 14 is enabled. Off: For location 7202 channel 6 is disabled, for location 7242 channel 14 is disabled. 7 Restore Channel 7/15 On: For location 7202 channel 7 is enabled, for location 7242 channel 15 is enabled. Off: For location 7202 channel 7 is disabled, for location 7242 channel 15 is disabled. 8 Restore Channel 8/16 On: For location 7202 channel 8 is enabled, for location 7242 channel 16 is enabled. Off: For location 7202 channel 8 is disabled, for location 7242 channel 16 is disabled. Fast Format: Open/Close Channels When the ARC protocol is programmed as Fast Format, the channels that report an Open/Close event can be enabled or disabled. Locations: 7203 - Open/Close Channels 1 – 8. 7243 - Open/Close Channels 9 – 16. Entry Mode: Bit Toggle Selection (see page 17). 1 Open/Close Channel 1/9 On: For location 7203 channel 1 is enabled, for location 7243 channel 9 is enabled. Off: For location 7203 channel 1 is disabled, for location 7243 channel 9 is disabled. 2 Open/Close Channel 2/10 On: For location 7203 channel 2 is enabled, for location 7243 channel 10 is enabled. Off: For location 7203 channel 2 is disabled, for location 7243 channel 10 is disabled. 3 Open/Close Channel 3/11 On: For location 7203 channel 3 is enabled, for location 7243 channel 11 is enabled. Off: For location 7203 channel 3 is disabled, for location 7243 channel 11 is disabled. 1 Restore Channel 1/9 On: For location 7202 channel 1 is enabled, for location 7242 channel 9 is enabled. Off: For location 7202 channel 1 is disabled, for location 7242 channel 9 is disabled. 4 Open/Close Channel 4/12 On: For location 7203 channel 4 is enabled, for location 7243 channel 12 is enabled. Off: For location 7203 channel 4 is disabled, for location 7243 channel 12 is disabled. 2 Restore Channel 2/10 On: For location 7202 channel 2 is enabled, for location 7242 channel 10 is enabled. 5 Open/Close Channel 5/13 On: For location 7203 channel 5 is enabled, for location 7243 channel 13 is enabled. 38 P0016-LI-03.01 Off: For location 7203 channel 5 is disabled, for location 7243 channel 13 is disabled. 6 Open/Close Channel 6/14 On: For location 7203 channel 6 is enabled, for location 7243 channel 14 is enabled. Off: For location 7203 channel 6 is disabled, for location 7243 channel 14 is disabled. 7 Open/Close Channel 7/15 On: For location 7203 channel 7 is enabled, for location 7243 channel 15 is enabled. Off: For location 7203 channel 7 is disabled, for location 7243 channel 15 is disabled. 8 Open/Close Channel 8/16 On: For location 7203 channel 8 is enabled, for location 7243 channel 16 is enabled. Off: For location 7203 channel 8 is disabled, for location 7243 channel 16 is disabled. Channel Type When the ARC protocol is programmed as Fast Format, the channel type must be allocated to a system output type. Locations: 7211 to 7218 Channels 1 to 8: Channel Type. 7251 to 7258 Channels 9 to 16: Channel Type. Entry Mode: Selection List (see page 16). Please refer to page 31 for a complete list of output types. Channel Attributes This set of options allows the output attributes to be assigned to the Fast Format channels. Locations: 7221 to 7228 Channels 1 to 8: Channel Attributes. 7261 to 7268 Channels 9 to 16: Channel Attributes. Entry Mode: Bit Toggle Selection (see page 17). Locations: Channels 1 to 4: Telephone Number 1. 7321 to 7324 Channels 1 to 4: Telephone Number 2. Entry Mode: This set of options allows the output areas to be assigned to the Fast Format channels. Locations: String Edit - Number Mode (see page 18). Whilst programming telephone numbers, addition characters can be inserted to perform the following: B1: Insert a “P” for a 1 second pause. B2: Insert a “F” to force blind dialling (no dial-tone detection). Speech Dialler: Dial Sequence This set of options allows the dial sequence to be programmed for each speech dialler channel. Locations: 7331 to 7334 Entry Mode: String Edit - Number Mode (see page 18). Channels 1 to 4: Dial Sequence. The call sequence is entered as a string of digits; each number indicates the calling method: 1: Dial Using Telephone No 1. 2: Dial Using Telephone No 2. The call attempts are controlled by how many digits are entered. Here are some typical examples: “1122” = Dial four times, first to telephone no 1 then telephone number 2. “1212” = Dial four times alternating between telephone number 1 and 2. Speech Dialler: Trigger Type Each speech dialler channel can be triggered from any of the system output types, for example channel 1 could be programmed to “Intruder Alarm” whilst channel 2 could be programmed to “Fire Alarm”. Please refer to page 31 for a complete list of output types and their corresponding type number. Locations: 7341 to 7344 Entry Mode: Selection List (see page 16). Channels 1 to 4: Trigger Type. Please refer to page 30 for a complete list of output attributes. Channel Areas 7311 to 7314 UDL Options 7241 to 7248 The set of options controls how the upload/download computer interacts with the control panel. Channels 1 to 8: Channel Areas. Location: 7400 7271 to 7278 Entry Mode: Bit Toggle Selection (see page 17). Channels 9 to 16: Channel Areas. Entry Mode: Bit Toggle Selection (see page 17). Speech Dialler: Telephone Numbers 1 and 2 The on-board communicator also features a 4 channel speech dialler which can be used to call landline or mobile telephones to play a recorded voice message. Each channel can have two telephone numbers assigned. When the channel is triggered the on-board communicator will dial the number specified by the dial sequence and play the voice message associated with the channel for up to 1 minute. Pressing the [#] key on the telephone handset acknowledges the call and stops the dial sequence, pressing any other key also acknowledges the call, but the dial sequence will continues with next number. The speech messages are recorded using the Eclipse UDL software package or a touch-tone telephone. The touch-tone method is covered in the “EC-P50 User Manual”. P0016-LI-03.01 1 2 Call Answer Phone Defeat On: Incoming calls re answered when: a) The remote UDL computer calls in and allows the panel to detect one or more rings. b) The remote UDL computer ends the call. c) The control panel answers the call immediately if the remote UDL computer calls again within 60 seconds. Off: Incoming calls are answered after the “Ring Count” threshold is reached. 2 Auto Call-Back On: After the remote UDL computer establishes a connection, the control panel ends the call and automatically calls the UDL computer. Off: Call-Back only occurs if the remote UDL computer requests it. 39 3 User Call-Back On: Remote UDL access can only be established if the user initiates from their end. Off: Remote UDL access is enabled at all times. 4 Disable UDL when Armed On: Remote UDL access is disabled when the system is armed. Off: Remote UDL access is enabled at all times. 5 Disable Online Keypad On: Remote UDL online keypad operation is disabled. Off: Remote UDL online keypad operation is enabled. UDL Password The UDL password provides communication security with the remote UDL computer. The UDL password in the control panel must match the UDL password configured in the Eclipse UDL software package in order to establish a communication link. Location: 7401 Entry Mode: Number Mode (see page 18). UDL Remote IP Address This is the IP Address of the remote UDL computer. Location: 7405 Entry Mode: String Edit - Number Mode (see page 18). UDL Remote IP Port This is the IP port number of the remote UDL computer. Location: 7406 Entry Mode: String Edit - Number Mode (see page 18). UDL Account Number This is the account number used by the Eclipse UDL database. The Eclipse UDL software will automatically assign this when you create a new account. However, the account number can be manually entered if required. Location: 7407 Entry Mode: String Edit - Number Mode (see page 18). The UDL password can be reset to a default setting of 123456 by entering *6# within 10 seconds of powering up the system. UDL Ring Count This counter controls how the on-board communicator takes to answer an incoming call. Location: 7402 Entry Mode: Number Mode (see page 18). Call-Back Number When using the call back feature of the Eclipse UDL software, the telephone number of remote UDL computer’s modem must be configured using this option. Location: 7403 Entry Mode: String Edit - Number Mode (see page 18). UDL Dial Sequence This set of options allows the dial sequence to be programmed when using the call-back feature. Location: 7404 Entry Mode: String Edit - Number Mode (see page 18). 1: PSTN (On-board Communicator) 2: SM Module 3: IP Module The call attempts are controlled by how many digits are entered. Here are some typical examples: “111” = Attempt to call-back the remote UDL computer three times using only PSTN. “1212” = Attempt to call-back the remote UDL computer four times alternating between PSTN and GSM. “123” = Attempt to call-back the remote UDL computer three times using PSTN, then GSM and finally IP. 40 P0016-LI-03.01 8. System Users This section covers programming of the system users. The EC-P50 has a total of 51 users: User 00 is the “Engineer” which has a default code of 1234. User 01 is the “Master” user which has a default code of 5678. Users 02 to 50 can be programmed to any user type and default to “Not in Use”. User Access Code Each user must be assigned an access code in order to operate the system; access codes may be 4, 5 or 6 digits in length. This option allows each user to be assigned an access code. Locations: 8100 to 8150 Users 00 to 50: Access Code. Entry Mode: String Edit - Number Mode (see page 18). The user type defines the level access the user has in order to operate the system. This option allows the selected user type to be assigned. User 00 and User 01 types cannot be changed. 8202 to 8250 Users 02 to 50: User Type. Entry Mode: User Locked By The user access can be locked out by the use of a “Link Controlled” output (see page 32). The “Link Control” output can be configured to switch on by various link input conditions, e.g., “Link Control 01” could be programmed to operate when Control Timer 2 is active. This means that the user access code is disabled when the selected “Link Control” output is on and can be used for locking out selected users for particular conditions, e.g. you may want to prevent a user from accessing the system over the weekend. Locations: 8300 to 8350 Users 00 to 50: User Locked By. Entry Mode: Number Entry (see page 18). User Name User Type Locations: 9 Access Control The selected user is an Access Control user and on entering the access code the relevant “User Access” and “Door Access” output is activated. Selection List (see page 16). 0 Not in Use The selected user is not in use. 1 Engineer The selected user is an engineer and can access all options within the engineer’s program menu. 2 Technician The selected user is a Technician and can access all options except the onboard communication options within the engineer’s program menu. 3 Master The selected user is a Master user and can access all options within the user menu and program new users. 4 Manager The selected user is a Manager user and can access all options within the user menu. Each user can be assigned a 8 character label that is displayed on LCD remote keypads when viewing the system event log. Locations: 8400 to 8450 Entry Mode: String Edit - Text Mode (see page 18). Users 00 to 50: User Name. User Link Each user can be assigned a “Link” number, which in turn is used to control “Link Control” output types, for details on link control, see page 32. Locations: 8500 to 8550 Users 00 to 50: User Link. Entry Mode: Number Entry (see page 18). User Areas Each user must be assigned to one or more areas in order for them to access the required area of protection. Users that are assigned to multiple areas will be given the option to select the areas they want to arm or disarm. Locations: 8600 to 8650 Users 00 to 50: Areas. Entry Mode: Bit Toggle Selection (see page 17). 5 Standard The selected user is a Standard user and can access the following options from the user menu: “Away Arm”, “Stay Arm”, “Do walk Test” and “Change Code”. 6 Local Standard The selected user is a Local Standard user and can access the following options from the user menu: “Away Arm”, “Stay Arm”, “Do walk Test” and “Change Code”. This user type can only arm and disarm areas that are assigned to both their code and keypad. For example, if the user is assigned to all areas, and keypad 1 is assigned to area 1, then the user can only arm and disarm area 1 from keypad 1. 7 Arm Only The selected user is an Arm Only user and can only access the arming options within the user menu. 8 Duress The selected user is a Duress user and operates the same as a standard user, however, on entering the access code a silent duress alarm is generated and if programmed, the event is signalled to alarm receiving centre. P0016-LI-03.01 41 9. Utilities User Menus This section covers the programming of the system utilities. The engineer can access the user menus without exiting the engineer’s program mode by entering 91*. The table below shows the user menu options and the command number used to access them. Time and Date The system has a real time clock that must be programmed so that the time and date is recorded correctly in the system event log. The time and date is also displayed on the bottom line of the LCD keypad. If the system looses all power, the time and date is maintained for approximately 2 days. Locations: Entry Mode: Group Command Function Arming A S Away Arm 9001 - Hours. 9002 - Minutes. 9003 - Seconds. 9004 - Day. 9005 - Month. 9006 - Year. Reset R Reset alarm or fault Walk Test Number Entry (see page 18). Event Log & UDL 11 12 13 21 22 23 24 81 91 92 98 99 Program Mode System Tests Users Menus Stay Arm Test Bell & Outputs Do Test Call View Log Print Log Call UDL Chime on/off Change code View Zone Status Confirm Devices Exit Menu When using the LCD keypad the menu options and their command numbers are scrolled on the bottom line of the LCD. If the * key is pressed, the menu option that is currently being displayed is selected. Away Arm A Selecting this option will cause the system to start the exit mode and attempt to away arm the system. To cancel or disarm simply enter a valid user code. Stay Arm S Selecting this option will cause the system to start the exit mode and attempt to stay arm (1) the system. To cancel or disarm simply enter a valid user code. Walk Test 11* Selecting this option allows the detection zones to be tested without causing an alarm. As each zone is activated, the keypad generates an acknowledgment tone and the zone number is added to the list of tested zones. The tested zones are scrolled on the keypad display. When you have finished testing the zones, press R to exit this option. Test Bell & Outputs 12* Selecting this option allows the bell, strobe and any outputs that have the “User Test” attribute to be switched on and off. After selecting this command keys 1 to 4 toggle on and off the following: Bell Output Strobe Output User Test Outputs Alarm Sounder Press R to exit this option. 1 2 3 4 Do Test Call 13* Selecting this option will cause the on-board communicator to send a test call to the alarm receiving centre. 42 P0016-LI-03.01 View Event Log 21* Selecting this option allows the event log to be viewed. The following keys are used when navigating through the log: Go backward. Go forward. Press R to exit this option. * # Print Event Log 22* Selecting this option causes the contents of the event log to be sent to the printer. Press R to exit this option. Either Com1 or Com2 must be configured for “Printer” mode in order to use this feature. Call UDL 23* Selecting this option will cause the on-board communicator to call the remote computer modem, so that a remote link can be established. The remote computer must be setup so that it is ready to receive the call. Only select this option when instructed to do so by the remote computer operator. Chime on/off 24* Selecting this option will globally turn chime on or off. Change Code 81* Selecting this option allows you to change your own access code. After selecting this option enter the new access code (4 - 6 digits) followed by *. Program Mode 91* Selecting this option takes you back to the normal engineer’s program mode. View Zone Status 92* Selecting this option either from engineer’s mode or the user menu allows you view the status/count of each zone. The following keys are used when using this option: View next zone. View previous zone. Press 0 to 4 to select the zone bank number. Press A to toggle between status and count. Press R to exit this option. # * Confirm Devices 98* Selecting this option either from engineer’s mode or the user menu allows you view and confirm the devices connected to the control panel network. See “Confirm Devices” on page 14. Exit Menu 99* Selecting this option returns the system to the normal disarmed state. P0016-LI-03.01 43 Log Events LCD LED Description +1/2!"/)/*GG IA ?? Intruder alarm activated by zone ??. +1/2!"/"01,/"GG IR ?? Intruder zone ?? restore. "/&*"1"/)/*GG PeA ?? Perimeter alarm activated by zone ??. "/&*"1"/"01,/"GG PeR ?? Perimeter zone ?? restore. :</)/*GG 24HrA ?? 24 hour alarm activated by zone ??. :</"01,/"GG 24HrR ?? 24 hour zone ?? restore. +1/6)/*GG EA ?? Entry alarm activated by zone ??. +1/6"01,/"GG ER ?? Entry zone ?? restore. /+&+$)/*GG WA ?? Warning alarm activated by zone ??. /+&+$"01,/"GG WR ?? Warning zone ?? restore. "!& ))/*GG DA ?? Medical alarm activated by zone ??. "!& )"01,/"GG DR ?? Medical zone ?? restore. &/")/*GG FA ?? Fire alarm activated by zone ??. &/""01,/"GG FR ?? Fire zone ?? restore. )/*GG PA ?? Panic alarm activated by zone ??. "01,/"GG PR ?? Panic alarm zone ?? restore. &)"+1)/*GG PSA ?? Silent panic alarm activated by zone ??. &)"+1"01,/"GG PSR ?? Silent panic alarm ?? restore. 25)/*GG AuA ?? Auxiliary alarm activated by zone ??. 25"01,/"GG AuR ?? Auxiliary zone ?? restore. ,+&1,/)/*GG MA ?? Monitor alarm activated by zone ??. ,+&1,/"01,/"GG MR ?? Monitor zone ?? restore. ,+"GG6-00"! By ?? Zone ?? bypassed. ,+"GG+6-00"! UBy ?? Zone ?? unbypassed. *-"/GG)/* TA ?? Tamper alarm activated by zone ??. *-"/GG"01,/" TR ?? Tamper zone ?? restore. ,+"GG2)1)/* FltA ?? Fault alarm activated by zone ??. ,+"GG2)1"01,/" FltR ?? Fault on zone ?? has restored. ,+"GG0()/* MA ?? Mask alarm activated by zone ??. ,+"GG0("01,/" MR ?? Mask alarm on zone ?? has restored. ,41Y)/*GG LB ?? Low battery alarm from wireless device on zone ??. ,41Y"01,/"GG LR ?? Low battery alarm on zone ?? has restored. 6-00 1&3"GG ByA ?? Group bypass activated by zone ??. 6-00"01,/"GG ByR ?? Group bypass by zone ?? has restored. "604&1 % 1&3"GG SA ?? Keyswitch connected to zone ?? is active. "604&1 %"01,/"GG SR ?? Keyswitch connected to zone ?? has restored. )/* 1&3" AA Intruder Alarm is active. "))0 1&3" BA Bell output is active. "X/*, (,21 RL Re-arm lockout has occurred and no more alarm can be generated for the armed period. ,+#&/*"!)/* CA Confirmed alarm generated (two different zones activated). "*,1" RA ?? Remote access via PC number ??. 0"/GG Ur ?? User access by user ??. 2/"00GG Dr ?? Duress alarm by user ??. 0"/$GG UT ?? User ?? proximity tag access. 0"/GG, (,21 UL ?? User ?? has been locked out from using the system. 0"/$GG, (,21 TL ?? User ?? proximity tag has been locked out from using the system. ,!"*-"/G CT ? Code tamper (invalid code) generated at keypad ?. 5&11/1"!GG ESU ?? Exit mode started by user ??. 5&11/1"!&*"/G EST ?? Exit mode started by control timer ?. 44 "00GG P0016-LI-03.01 LCD LED Description 5&11/1"!,+"GG ESC ?? Exit mode started by zone ??. 5&11,--"! ES Exit mode stopped. 5&1&)"!QGG EF ?? Exit mode failed by zone ??. +1/61/1"!GG EN ?? Entry mode stared by zone ??. +1/6&*",21 ET Entry timeout alarm. 601"*/*"! SA System armed. 601"*&0/*"! SD System disarmed. 16/*"!QG S ? Stay armed #? (? = 1, 2 or 3). /*&)"!QG AF ? Arming failed. /*"!&1%2)1 AU The system was armed with an Alarm Transmission System (ATS) fault. 21,/*"! AA The system was automatically armed. 21,&0/*"! AD The system was automatically disarmed. "*,1"/*"! RA The system was automatically armed remotely. "*,1"&0/*"! RD The system was automatically disarmed remotely. 601"*,4"/- SU The system was powered up. &)"! ACOff The mains ac supply has been switched off. "01,/" ACOn The mains ac supply has been restored. 11"/62)1QG BF Battery fault #? (1: Presence Fail; 2: Load Test Fail). 11"/6"01,/" BR Battery fault restored. ,411"/6)/* LB The system standby battery voltage is low (The system is running on battery only). &*"Z1"%+$"! TD The system time and date has been changed. +$&+""/,+0&1" ENON The engineer access code has been entered. +$&+""/,##0&1" ENOF The engineer has logged off. "))20")/* BFAL The bell fuse has gone open circuit (electronic fuse). "))20""01,/" BFAR The bell fuse has restored. 2520")/* AFAL The auxiliary 12V fuse has gone open circuit (electronic fuse). 2520""01,/" AFAR The auxiliary 12V fuse has restored. 11"/620")/* BFAL ? The battery fuse has gone open circuit (electronic fuse). 11"/620""01,/" BFAR The battery fuse has restored. ,5*-"/)/* BTAL The control panel box tamper has been activated. ,5*-"/"01,/" BTAR The control panel box tamper has restored. "6-!G*-"/ RTAL ? Keypad ? box tamper has been activated. "6-!G*-"01 RTAR ? Keypad ? box tamper has restored. "3& "GG,01 RL ? Device ?? on network lost. "3& "GG,2+! RF ? Device ?? on network found. )(1"011/1"! TS User walk test mode started. )(1"01+!"! TE User walk test mode ended. "))"011/1"! BTS User bell test started. "))"01+!"! BTE User bell test ended. 21,"01)) ATC An automatic test call was sent to the Alarm Receiving Centre (ARC). +2)"01)) TC A manual (user) test call was sent to the Alarm Receiving Centre (ARC). &*"/G+ CT ? ON Control Timer ? is on. &*"/G## CT ? OFF Control Timer ? is off. ,+""01GG60 TS ?? Zone soak test has started and will run for ?? days. ,+"GG"01&) TF ?? Zone ?? has failed whilst on test. &/01+, (GG FN ?? First activation from zone ??. The zone has the “Double Knock” attribute. )/*,/1"! AA The user has disarmed the system within the abort delay period. "))*-"/)/* BTAL The bell tamper alarm has been activated. "))*-"/"01,/" BTAR The bell tamper has restored. 2)1 ATSF The Alarm Transmission System (ATS) has detected a fault with the telephone line. "01,/"! ATSR The ATS Fault has restored. P0016-LI-03.01 45 LCD LED Description "6-!G RP ? A A panic alarm was generated at keypad ? by pressing keys 7 and 9. "6-!&/"G RF ? A A fire alarm was generated at keypad ? by pressing keys 1 and 3. "6-!"!& )G RD ? A A medical alarm was generated at keypad ? by pressing keys 4 and 6. 21-21G2)1 OPF ? The control panel has detected a fault on panel output ?. 21-21G"01,/" OPR ? The fault on panel output ? has restored. ,*,!2)")/* C?A The communication module has been disconnected/lost from com port ?. ,*,!2)""01,/" C?R The communication module has been connected/found from com port ?. ,+"GG,2+1)/* ??CA Zone ?? has reached the “Count Logging” threshold. 46 P0016-LI-03.01 LED Indications The figure bellow shows the LED indicators for both the LED and LCD remote keypads: Icon Name LED Description Power Green Mains AC power is present. Ready Green The system is ready for arming. Armed Green The system is armed (Away or Stay). Fault Yellow The system has one or more faults. Bypass Yellow One or more zones are bypassed. Alert Red One or more faults/alarms require attention. Alarm Red One or more alarms have occurred. Fault & Status Messages Faults and status messages may be indicated during the disarmed mode or after the user disarms the system. The table below shows the message for both the LED and LCD remote keypads: LCD LED Description *&+0,## AC Mains AC power is off. 11"/62)1 BF The standby battery in the control panel has a fault. %,+"&+"2)1 LF The on-board communicator has detected a fault with the telephone line. +")*-"/ PT The box tamper on the control panel has activated. "))*-"/ BT The bell tamper on the control panel has activated. ))+$&+""/ CE Call engineer to reset the system. "/3& "".2&/"! CR The service timer has expired and the installation company should be contacted. :X&/"*,(")/* SA One or more 2-wire smoke detectors have activated a fire alarm. :X&/"*,("2)1 SF One or more 2-wire smoke detectors have a fault. "6-!G,01 R? Keypad ? is no longer reporting to the control panel. "6-!G*-"/ T? The box tamper on keypad ? has activated. 5-+!"/9,01 E1 Expander 1 is no longer reporting to the control panel. 5-+!"/9*-"/ t1 The box tamper on expander 1 has activated. 21-21G2)1 O? Output ? on the control panel has a fault. ,+"GGB)/*"! ?? Alarm activated on zone ??. Resetting Faults & alarms If a fault or alarm has occurred it can be reset as follows: 1. Enter a valid access code, this will silence the alarm or cancel the alert. 2. Enter a valid access and press R to reset the system. 3. Enter *99 to exit the menu. If the fault is still present it will still be indicated. 4. Specifications P0016-LI-03.01 47 EC-P50 Control Panel Electrical Supply Voltage: Rated PSU Output: Ripple: Current: 230VaC. 1.5A. <5%. <100mA quiescent. <150mA in alarm. Standby Battery: 12.0V SLA, 7Ah. Recharge Time: 24hr @300mA; 10hr @750mA. Low Voltage Alarm: 10.5V. Deep Discharge Cut-off: 9.5V. Fuses: Mains: 315mA, 250V, 20mm. Auxiliary 12V: 900mA PTC. Bell: 900mA PTC. Battery: 1.6A PTC. On-board Zones: 10. Panel Outputs 1 - 5: 1A switched to 0V (supervised). Speaker Output: Minimum load 16Ω. 2-Wire Smoke Detectors: ESL429CT or System Sensor 2100TS. On-board Communicator: Protocols: Fast Format, Contact ID, Voice, SMS ETSI ES 201 912 protocol 1, Speech Dialler and V21 Modem. Dialling: Pulse or DTMF. REN Rating: 1.0. Environmental Operating Temperature: Storage Temperature: Max. Humidity: EMC: -25°C to +55°C (-13°F to +131°F). -25°C to +60°C (-13°F to +140°F). 95% non-condensing. Residential, commercial and light industrial. Do not throw away the product with the normal household waste at the end of its life, but hand it in at an official collection point for recycling. The onboard battery also contains substances that may pollute the environment. Always remove the battery before you discard and dispose of the battery at an official collection point for batteries. Physical Dimensions: Housing: Packed Weight: 280.0mm x 255.0mm x 95.0mm. 3mm Polycarbonate. 975g. Environmental Operating Temperature: Storage Temp.: Max. Humidity: EMC: -25°C to +55°C (-13°F to +131°F). -25°C to +60°C (-13°F to +140°F). 95% non-condensing. Residential, commercial and light industrial. Physical Dimensions: Housing: Packed Weight: 130.0mm x 102.0mm x 27.0mm. 3mm Polycarbonate. 225g. EC-LCD Remote Keypad Electrical Voltage: Current: 9 – 16VDC. 20mA quiescent. 30mA when active. Environmental Operating Temperature: Storage Temperature: Max. Humidity: EMC: -25°C to +55°C (-13°F to +131°F). -25°C to +60°C (-13°F to +140°F). 95% non-condensing. Residential, commercial and light industrial. Physical Dimensions: Housing: Packed Weight: 102.0mm x 130.0mm x 27.0mm. 3mm Polycarbonate. 225g. EC-EX10/I Zone Expander Electrical Voltage: Current: Zone Inputs: Auxiliary 12V: 9 – 16VDC. 30mA. 10 fully programmable. Protected by 1A electronic fuse (PTC). Environmental Operating Temperature: Storage Temperature: Max. Humidity: EMC: -25°C to +55°C (-13°F to +131°F). -25°C to +60°C (-13°F to +140°F). 95% non-condensing. Residential, commercial and light industrial. Physical Dimensions: Housing: Packed Weight: 136.0mm x 174.0mm x 35.0mm. 3mm Polycarbonate. 250g. EC-EX10 Zone & Output Expander Electrical EC-LED Remote Keypad Electrical Voltage: Current: P0016-LI-03.01 9 – 16VDC. 25mA quiescent. 40mA when active. Voltage: Current: Zone Inputs: Outputs: Loudspeaker: Auxiliary 12V: 9 – 16VDC. 40mA. 10 fully programmable. OP1-8: 100mA; OP9-10: 1Amp. Minimum load of 16Ω. Protected by 1A electronic fuse (PTC). Environmental Operating Temperature: -25°C to +55°C (-13°F to +131°F). Storage Temperature: -25°C to +60°C (-13°F to +140°F). 48 Max. Humidity: EMC: 95% non-condensing. Residential, commercial and light industrial. Security Conforms to EN 50131-1 Environmental Class IV. and EN 50131-3 Grade 2, Physical Dimensions: Housing: Packed Weight: 136.0mm x 174.0mm x 35.0mm. 3mm Polycarbonate. 350g. EC-EX10/O Output Expander Electrical Voltage: Current: Outputs: Auxiliary 12V: 9 – 16VDC. 30mA. OP1-8: 100mA; OP9-10: 1Amp Protected by 1A electronic fuse (PTC). Environmental Operating Temperature: Storage Temperature: Max. Humidity: EMC: -25°C to +55°C (-13°F to +131°F). -25°C to +60°C (-13°F to +140°F). 95% non-condensing. Residential, commercial and light industrial. Physical Dimensions: Housing: Packed Weight: The CE mark indicates that the EC-P50 complies with the European requirements for safety, health, environment and customer protection. Warranty Zeta Alarm Systems by GLT Exports Ltd products are carefully designed to provide reliable problem-free operation. Product quality is carefully controlled during all manufacturing processes. The EC-P50 is covered against defects in material or faulty workmanship for a period of 2 years from the date of purchase. Due to our policy of continuous product improvement, Zeta Alarm Systems by GLT Exports Ltd reserves the right to change specification without prior notice. As the EC-P50 is not a complete intruder alarm system, but only part of it, Zeta Alarm Systems by GLT Exports Ltd does not accept responsibility or liability for any damages whatsoever based on any claim that the unit failed to function correctly. 136.0mm x 174.0mm x 35.0mm. 3mm Polycarbonate. 250g. EC-COM/IP Communication Module Electrical Voltage: Current: 9 – 16VDC. 70mA. Environmental Operating Temperature: Storage Temperature: Max. Humidity: EMC: -25°C to +55°C (-13°F to +131°F). -25°C to +60°C (-13°F to +140°F). 95% non-condensing. Residential, commercial and light industrial. Physical Dimensions: Packed Weight: 65.0mm x 55.0mm x 15.0mm. 100g. Standards Safety Conforms to European Union (EU) Low Voltage Directive (LVD) 2006/95/EC. EMC Conforms to European Union (EU) Electro-Magnetic Compatibility (EMC) Directive 2004/108/EC. P0016-LI-03.01 49 Notes 50 P0016-LI-03.01 Notes P0016-LI-03.01 51 Technical Support Email: [email protected]
advertisement
Related manuals
advertisement