INSTALLATION AND SETUP GUIDE

GENERAL INFORMATION

The ADEMCO 6150V and ADEMCO 6160V are addressable remote keypads designed for use with ADEMCO control panels and provide the following features:

• Backlit Display

• Programmable Function Keys

• Voice Chime

• Voice Status

• Built-in Sounder • Message Center

• Supervised by control panel (if supported)

Notes:

When used with the ADEMCO VISTA-15P/VISTA-

20P control panels, address 16 must be assigned to the first keypad. Additional keypads must be assigned to address 17 – 23. Refer to Setting The

Keypad Options.

• Keypad keys are continuously backlit for convenience.

• Permanent display backlighting is an option on some controls (refer to control panel’s instructions for details).

• Voice Chime should only be enabled when used with control panels that support the "chime by zone" mode

(e.g., VISTA-15P/VISTA-20P). This mode must be enabled at the control panel. Refer to the control panel's installation and setup guide for information on how to program the chime mode.

Use only zone descriptors supported by this keypad. If using zone descriptors not supported by this keypad, you must turn voice status and voice chime off. Table 1 is a list of applicable zone

descriptors and index entries. Refer to the control panel’s installation and setup guide for information about how to program zone descriptors.

• For the 6160V ONLY, supervision must be enabled for commercial fire installations.

UL NOTE: ADEMCO 6150V cannot be used for commercial fire applications.

KEYPAD DISPLAYS AND LEDS

The keypads have the following display features:

Model Fixed 2-Line 2-Digit Custom

Word

Display

Alpha

Display

Zone

Identifier

Zone

Descriptors

X X 6150V

6160V X X

The following table identifies the keypad’s LEDs and associated functions:

LED Function

ARMED Lights red when the system is armed in any mode.

READY Lights green when the system is "ready" to be armed.

MESSAGE Flashes red when message waiting or lights red

(steady) when in record mode.

PROGRAMMABLE FUNCTION KEYS

The keypad's programmable function keys [A, B, C] are normally used for keypad panic functions, but they can be programmed for other special functions instead. If they are programmed for other special functions, the associated keypad key pairs still provide the respective panic alarm (if programmed). Refer to the control panel’s Installation &

Setup Guide for details.

Function

Keys

A

B

C

D

Equivalent Key Pairs

[1] and [*]

[*] and [#]

[3] and [#]

NONE

• Function keys must be held down for at least 2 seconds to activate the programmed

function.

If functions other than panics are assigned to the programmable function keys, programmed panics must be initiated by pressing the programmed key pair.

FUNCTION KEY LABELS

A set of adhesive-backed labels with some typical function symbols (i.e., fire, police, personal emergency, etc.) is provided. These labels can be placed on or next to the keys to identify each key's function for the end user (as determined by the capability and programming of the control panel; refer to the installation and setup guide for the control panel).

A

B

C

D

ARMED

READY

MESSAGE

MIC

1

OFF

RECORD

4

MAX

7

INSTANT

READY

STATUS

2

AWAY

VOLUME

5

TEST

8

0

CODE

VOICE

3

STAY

PLAY

6

BYPASS

9

CHIME

#

FUNCTION

SIDE

VIEW

MOUNTING RELEASE SNAPS

(Remove case back by pushing up the 2 "snaps" along the keypad's bottom edge and pulling the case apart.)

WIRING AND INSTALLATION

Keypads can be surface mounted using drywall anchors or to a single- or double-gang electrical box.

1. Remove the case back by pushing up the two "snaps" along the keypad’s bottom edge and pulling the case apart. See diagram above.

2. Route wiring from the control panel through the opening in the case back.

3. Mount the case back to a wall or electrical box.

4. Wire directly from the keypad’s terminal block to the terminal block on the control board. (See Wiring

Table that follows.) Use only 16-24 AWG wire.

Keypad

G

Wiring Table (All Keypads)

Control Panel

Data In

Wire Color

Green

+

Y

– Aux Pwr (GND)

+ Aux. Pwr

Data Out

Black

Red

Yellow

5. Re-attach the keypad to the case back.

6. Remove clear protective film from LEDs (6160V

only).

SETTING THE KEYPAD OPTIONS

The procedures that follow are used to set the keypad address, voice chime mode, and additional voice keypad mode.

Setting The Keypad Address

When used with the VISTA-15P/VISTA-20P control panels, address 16 must be assigned to the first Keypad. Additional Keypads must be set at 17 - 23 and must be enabled additionally

in control programming (fields *190 - *196).

The keypad can either be set for an address of 00-30 or for non-addressable mode (31). The default keypad address is

31. For valid address settings for your keypad, refer to the control panel's Installation & Setup Guide.

Note:

• If unable to enter the address mode, power down, power up, and try again.

• If 10 seconds pass with no key entry, the keypad automatically exits the address mode. You must power down, power up, and start the address mode again.

• The keypad will not enter the address mode if the control panel is in programming mode.

1. Apply power to the keypad.

2. Within 60 seconds of applying power to the keypad, press and hold down the [1] key and [3] key at the same time for 3 seconds. The current keypad address will be displayed.

3. Press "00".

The current address is cleared.

4. Enter desired keypad address.

"ADDITIONAL CON" (alpha keypad) or "A" (fixed keypad) is displayed along with the selected mode "1" or

"0".

Note: Setting Voice Chime mode off does not effect the voice status or alarm annunciation.

Setting The Additional Console Mode

The Additional Console mode must be set for all voice keypads being used.

8. Set the voice keypad Additional Console mode as follows: a. On the Primary voice keypad, press [0] to set the

Additional Console mode to NO. b. On any secondary voice keypads, press [1] to set

Additional Console mode to YES.

9. Press [*] to save the mode.

VIEWING THE KEYPAD ADDRESS

Press and hold down the [1] key and [3] key at the same time for about 3 seconds. The current address is displayed.

No key entry is allowed. Press any key to exit or wait 10 seconds to exit the viewing mode.

OPERATING THE KEYPAD

For operating instructions, see the User Guide for the control panel used with this keypad.

SPECIFICATIONS

Physical:

6150V:

6160V:

Displays:

4-7/8"H x 6-1/4"W x 1"D

5-5/16"H x 7-3/8"W x 1-3/16"D

6150V:

6160V:

(backlit)

Sounder: Speaker

Electrical:

Fixed-Word LCD (backlit)

2 x 16 Alpha-Numeric Super twist LCD

5. Press [*] to save the displayed address and enter the

Voice Chime mode. "VOICE CHIME" (alpha keypad) or

"C" (fixed keypad) is displayed along with the selected mode "1" or "0".

Setting The Voice Chime Mode

6. Press [1] to set the Voice Chime mode on or press [0] to set the Voice Chime mode off.

7. Press [*] to save the displayed Voice Chime mode and enter the Additional Console voice keypad mode.

Current:

6150V: 160mA (ARMED LED lit, LCD backlight and sounder on) reduces to 60mA when panel is operating in standby mode (backlight off).

6160V: 190mA (ARMED LED lit, LCD backlight and sounder on) reduces to 60mA when panel is operating in standby mode (backlight off).

NFPA72 Compliant.

TABLE 1. ZONE DESCRIPTORS AND INDEX ENTRIES

057 KITCHEN 105 PATIO 146 UPSTAIRS 207

CLOSED

DEN

DETECTOR

DINING

040

050

052

053

GUN

HALL

HOUSE

INSIDE

067

071

079

080

085

089

094

LAUNDRY

LIBRARY

LIVING

MAIN

MASTER

MEDICAL

MOTION

095 OFFICE

099 OPEN

101 PANIC

106

109

113

122

123

125

131

POLICE

POOL

ROOM

SHED

SHOP

SIDE

SLIDING

136 SMOKE

138 STORAGE

144 SUPERVISED

151

152

162

168

170

173

175

176

185

190

UTILITY

WINDOW

YARD

ZONE

1ST

2ND

3RD

228

230

232

208

217

223

225

REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED FOR

WARRANTY INFORMATION AND LIMITATIONS OF THE ENTIRE ALARM SYSTEM.

For the latest warranty information, please go to: http://www.security.honeywell.com/hsc/resources/wa/index.html

www.security.honeywell.com

2 Corporate Center Drive, Suite 100, P.O. Box 9040, Melville, NY 11747

Copyright

2009 Honeywell International Inc

.