advertisement
John Guest Speedfit Limited
Horton Road, West Drayton, Middlesex UB7 8JL, England.
Tel: 01895 449233 Fax: 01895 420321. www.speedfit.co.uk
Technical Help Desk: 01895 425333
No.’s 95/3177
BS7291
KM39767
THE PUSH-FIT SOLUTION FOR
PLUMBING & HEATING SYSTEMS
CI/SfB
53.0
Ih6
The company has a policy of continuous research and development and reserves the right to amend without notice the specification and design of all products illustrated in this catalogue. John Guest
Speedfit reserve the right to change the colour and shape of products. Photographs are for illustration purposes only.
Subject to our Terms and Conditions of Sale available on request.
, and are registered trademarks of
John Guest International Limited
© Copyright 2007.
AVAILABLE FROM:
Z2105/217/10/07
UK PRODUCT RANGE AND
INSTALLATION GUIDE
October 2007
Worldwide connections
The John Guest Group has a long established reputation as a world leading manufacturer of push-in fittings, tube and other fluid control products. A reputation built on producing consistently high quality products with an ongoing commitment to value engineering and product development.
THE PUSH-FIT SOLUTION FOR
PLUMBING AND HEATING SYSTEMS
JG Speedfit is a push-fit system suitable for the plumbing of normal domestic hot and cold water services and central heating applications, including pressurised and combi systems.
The System is approved by the BRA and the WRAS.
Speedfit ‘PEM’ fittings and PEX and Polybutylene Barrier
Pipe are Kitemarked to BS7291 Parts 1, 2 and 3 Class S
Licence No KM39767.
01
Quality Manufacture
A commitment to quality is at the heart of the John Guest Philosophy.
The strictest control is maintained by virtue of the fact that design and manufacture is carried out in modern purpose built manufacturing centres in west London and at Maidenhead in
Berkshire.
Maintaining control over the whole process from initial tool design and tool making through to final assembly and testing ensuring that only products of the highest quality are produced.
The company believe it is this commitment to quality that has led to it receiving prestigious awards from many of the world’s leading testing and approvals organisations.
John Guest is a preferred supplier to many international companies.
Performance specifications are well within those required for most normal domestic central heating and water supply systems including:
• Mains fed and indirect cold water systems
• Vented and unvented hot water systems
• Vented central heating systems
• Sealed central heating systems provided temperatures and pressures comply with
BS7291 Parts 1, 2 and 3 Class S.
• Underfloor heating
Technical Support
Our national team of Technical Support Engineers is available to help you get the best from your S ee dffiitt
System. This includes a free underfloor heating estimate and CAD design service.
T ec niic all H p D es
JG S ee ee dffiitt
System. The service is available 8:00am to 5:00pm
Monday to Friday.
Speedfit Fittings have been designed for use with both
Speedfit and copper pipe.
Extensive tests have shown that Speedfit products will withstand temperatures and pressures well in excess of normal working conditions.
JG Speedfit should be installed to conform with good plumbing practice.
British Gas Service has accepted the John Guest Speedfit
System as being suitable for open vented and sealed central heating systems and as eligible for acceptance onto its service contracts.
British Gas
Service
Speedfit PEX Fittings and Barrier Pipe.
K24076, K24077 and K24078
BS7291
No. KM39767
02
03
SYSTEM FEATURES
• All white system
• Truly demountable without damage to pipe or fitting
• Grip and seal connection
• Superseal Insert gives secondary seal
• Reduced pipe insertion force
• Lightweight and easy to handle on site
SYSTEM BENEFITS
• Installation time reduced by up to 40%
• Pipe flexibility permits the cabling of pipe through less accessible areas
• No risk of fire or flames from a blowtorch
• Easier to work in confined places
• A permanent leak-proof connection
• Corrosion free
• No scale build up
• Lower thermal diffusivity maintains safer surface temperature
• Pipe elasticity can reduce the possibility of bursting under freezing conditions
• Lead free and non toxic
• Less noise from water flow and expansion/contraction
• Long pipe lengths reduce fittings required
GUARANTEE
As a result of long term test programmes and rigorous quality standards, John Guest Speedfit Limited offer a 25 year guarantee against the defects in materials or manufacturing of ‘PEM’, ‘PSE’ and ‘SFM’ Range
Plumbing Fittings and Speedfit Barrier Pipe manufactured by John Guest.
John Guest Underfloor Heating Products, which should be installed and maintained in accordance with our recommendations, carry a 2 year guarantee against defects in materials and manufacture.
John Guest Plumbing and Heating Products are for use with normal UK domestic plumbing and heating systems and supplied in accordance with our Conditions of Sale.
SPECIAL APPLICATIONS
Boats. The flexibility of the Speedfit System ensures it can be cabled easily around the interior and hidden from view.
Caravans. Speedfit is ideal for caravan installations due to its flexibility and its resistance to corrosion and freezing.
Exhibitions. The unique ability of the Speedfit System to be easily demounted and reused, together with its flexibility, makes Speedfit ideal for this application.
Agricultural and Horticultural.
Speedfit has many applications in agricultural and horticultural environments.
Portable Buildings (site cabins, toilets). As with caravans,
Speedfit is well suited to this application.
WORKING TEMPERATURES AND PRESSURES
Application Usual Working Maximum working Maximum working temperature, ºC temperature, ºC pressure, bar
20 20 12 Cold Water
(indirect and direct mains)
Central Heating 82 3
Hot Water
(including unvented cylinders)
65
105, short term malfunction at 114
95 6
Speedfit fittings suitable for central heating systems can withstand temperatures up to 114°C intermittently for short periods.
Speedfit fittings shown as not suitable for central heating systems are used primarily on the domestic hot and cold water system accepting temperatures of up to 65°C.
HANDLING FITTINGS AND PIPE
Ensure fittings and pipe are kept clean at all times by keeping them in bags and boxes provided.
Do not empty Speedfit Products onto the floor area.
Ensure internal ‘O’ Ring seals are kept free from dirt and debris.
PRODUCT SELECTION AND INSTALLATION
John Guest fittings and related products are specifically designed and manufactured by John Guest to the
Technical Specifications set out in the John Guest
Product Catalogues. All John Guest fittings and related products should be selected, installed, used and maintained in accordance with these Technical
Specifications. It is the customer’s / user’s responsibility to ensure that John Guest fittings and related products are suitable for their intended applications, are properly installed and maintained and are used in accordance with the Technical Specifications. It is also the customer’s / user’s responsibility to provide it’s own customers with any relevant technical information about John Guest products it supplies them.
Speedfit should not be used for gas, fuel oil or compressed air applications.
John Guest produce a push fit system of pipe and fittings for compressed air situations. See seperate literature for details.
Contents
PLUMBING AND HEATING
Plumbing and
Heating Fittings
09 - 10
Flexi Hoses 11 - 12
Brass Fittings
Valves
Pipe and
Accessories
12
13
14 - 15
UNDERFLOOR HEATING
Designed to be quick and easy to install.
22 - 26
UNDERGROUND FITTINGS
For connecting MDPE
Cold Water Service Pipe.
27 - 28
TECHNICAL CHECKLISTS
Plumbing and Heating 29
Underfloor Heating
Underground Fittings
30
30
04
05
HOW SPEEDFIT WORKS
Speedfit Fittings have a unique grip then seal construction made up of a collet with stainless steel teeth to grip the pipe and an ‘O’ ring to provide a permanent leak proof seal.
Use of the
Superseal Pipe Insert ensures a double ‘O’ ring seal.
An ‘O’ ring at the head of the insert and the shape of the stem, provide a secondary seal against the bore of the fitting. A combination of this and the main ‘O’ ring ensure a good connection.
The stem of the insert gives greater rigidity of the length of pipe within the fitting, reducing the chance of leaks if a side load is applied.
The head of the insert has been designed for ease of insertion.
The additional benefit of Twist and Lock Fittings is that a twist of a screwcap locks the pipe in position and gives increased compression on the ‘O’ ring for even greater security.
Grips before it seals
Stainless steel teeth grip the pipe
Pipe insert gives secondary seal
Main ʻOʼ Ring Seal
MAKING A GOOD CONNECTION
PREPARE THE PIPE
Fittings and pipe should be kept clean bagged and undamaged before use.
Pipe Cutter
JG TS
Speedfit
Barrier Pipe
Ensure the pipe is free of score marks. Cut the pipe square.
When using Speedfit Barrier Pipe cut along an insertion mark. We recommend the use of JG Pipe
Cutters.
To prevent damage to the ‘O’ ring remove all burrs and sharp edges.
When connecting Speedfit Pipe use a Superseal Pipe Insert. A twisting motion will aid insertion.
The insert should only be used with Speedfit Pipe.
NEW TWIST AND LOCK FITTINGS
Gap between Cap and Flange
Pipe mark indicates full insertion
The fitting should be in the ‘unlocked’ position, this is shown with a small gap between the screwcap and the body flange.
Push the pipe fully into the fitting, up to the pipe stop. If the Speedfit Pipe has been cut correctly the insertion mark on the pipe will be level with the collet head. The ‘O’ ring on the Superseal Pipe Insert provides a secondary seal against the bore of the fitting.
A good connection has been made.
If you are not using collet clips, ensure that the screwcaps are in the locked position.
Pull to check it is secure. It is good practice to test the system prior to leaving the site or before use. Our recommended test procedure is shown in our Technical Checklist.
ADDED BENEFIT TWIST AND LOCK
Twist the screwcap until it touches the body flange.
This increases the ‘O’ ring seal around the pipe and locks the pipe into position.
STANDARD SPEEDFIT FITTINGS
Push pipe up to stop
Secondary Seal
Pipe mark indicates full insertion.
Standard Speedfit connections are made in the same way as Twist and Lock.
Push Pipe up to Pipe Stop. If the Speedfit Pipe has been cut correctly the insertion mark on the pipe will be level with the collet head.
Pull to check connection is secure and test the system. Our recommended test procedure is shown in our Technical Checklist on page 29.
TO DISCONNECT
Ensure that the system is depressurised.
The screwcap on Twist and Lock Fittings will need to be turned back to the unlocked position.
Push the collet square against the face of the fitting by using fingers or with the help of our collet release tool.
With the collet held in position the pipe can be removed.
The fitting can be used again without the need for replacement parts.
WHAT
NOT
TO DO
Don’t use hacksaws to cut the pipe or leave burrs on the end of the pipe.
✗
Don’t use damaged or scored pipe.
✗
Fitting may be gripped but not sealed if pipe is not fully inserted.
✗
Don’t forget to push the pipe fully into the fitting, past both the collet (gripper) and the ‘O’ ring.
Do not insert fingers into the fitting as the stainless steel teeth may cause injury.
Remember to pressure test the completed installation according to the recommendations in our Technical Checklist.
06
07
PIPE STOP DISTANCES
Stops are located at the following distances from the end of the fitting: size 10mm 15mm 22mm 28mm stop distance 20mm 30mm 35mm 44mm
COLLET COVERS
Use a collet cover or collet clip to provide added security against pipe disconnection, e.g. the fitting coming into contact with rigid surfaces and behind dry-lining walls.
Collet covers for use with standard Speedfit fittings, are available in white or in red or blue to allow colour coding of pipes.
Collet cover
STOP END
Stop end
The unique feature of the
Speedfit Concept, the ability to disconnect the fitting should you want to, means the Speedfit Stop End not only provides a permanent leakproof seal, but can be readily removed to allow work to restart or to allow an extension to a system.
Thus, the fitting is especially useful to allow water to be turned back on, overnight for instance, or if a job has to be interrupted for another reason.
Stop ends are also useful when pressure testing a system before appliances are connected.
STEM ELBOW
Designed to simplify pipe connection in restricted spaces. The Speedfit
Stem Elbow provides an instant swivel fitting so pipe can be orientated in any direction.
A special 10mm version gives a neat connection from concealed plumbing to a radiator
.
COLLET CLIPS
Collet clip
SERVICE VALVE
Collet clips are available in grey and white for use with standard fittings to prevent accidental pipe disconnection.
Red or blue collet clips provide colour coding of pipe on twist and lock fittings.
They are not designed to prevent accidental release and should be fitted when the fitting is in the locked position.
RELEASE AID
The action of pressure in a system could increase the grip of the collet. The release aid allows a firmer grip on the collet whilst removing the pipe.
Release aid
The Speedfit range of brass chromium plated service valves can be used on both hot and cold water services and central heating. Push fit connections mean much reduced installation time, especially in confined spaces.
The valves, in 10 to 22mm, have a 1/4 turn open/close mechanism operated by a screwdriver slot or a lever.
Tap connector patterns have a u n i o n n u t t o c o n n e c t direct to a tap or floatvalve.
Lever operated valves are supplied with both a blue and a red indice.
The ability of Speedfit products t o t w i s t w h i l s t i n s i t u allows the screwdriver slot operating valve to be turned out of sight, helping to avoid unauthorised tampering.
Speedfit x Speedfit
Mechanism twists out of sight
TAP CONNECTORS
Speedfit manufacturer a wide range of connectors including conventional straight and bent tap connectors.
The range also offers a special and unique Tap Connector that only requires a simple hand tightening to connect up a terminal tap, mixer or float valve. An integral seal within the fitting avoids the need for further sealant. The connectors are useful when replacing existing brassware or in other confined spaces.
Coupling up to a supply is easy. The pipe is simply pushed home into the Speedfit connection and is instantly secured, without the need for specialist tools.
FLEXI HOSES
SPEEDFIT MANIFOLD
Speedfit have introduced an innovative 22mm x 10mm 4 way manifold. Departing from the usual manifold design, this new product has 4 in-line 10mm outlets, offering a neater envelope size and therefore a much smaller installation space.
Other benefits include better flow characteristics and a more even distribution of hot water.
The 22mm and 10mm Speedfit push-fit connections make for a fast and easy installation, even in confined spaces.
Whilst designed as a heating product, the manifold can also be used in a mains pressure hot or cold domestic plumbing system, to feed bathroom or kitchen taps and mixers. This allows for a more efficient installation as every terminal fitting has its own dedicated supply.
APPLIANCE TAP
The Speedfit range includes an Appliance Tap for the permanent connection of washing machines and dishwashers, thus enabling complete water isolation to the appliance.
Manufactured to a quality you would expect from Speedfit, our range of Flexi Hoses has 40 different patterns.
Available in lengths from 150mm to 1,000mm, ends are either push fit to union nut or push fit to push fit, including hoses with an integral service valve operated by a 1/4 turn screwdriver slot.
Apart from being aesthetically pleasing the new white hoses offer more flexibility and a larger through bore for better flow characteristics.
A simple push fit connection of the supply pipe and a plastic thread on the outlet to marry well with the plastic thread on the hose means the Speedfit Appliance Tap is very easy to install. The large round handle is easy to grip and turn.
SUPERSEAL PIPE INSERT
The Superseal Pipe Insert has been developed to be used with Speedfit Barrier Pipe and Speedfit Fittings to provide an extra line of defence when installing a Speedfit Push
Fit System.
The insert has it’s own ‘O’ ring which, with a stem sliding within the inside of the pipe, gives a secondary seal against the inside of the fitting.
More specialist patterns have been designed to help the installation of monobloc mixers to a 15mm supply.
Sold in pairs, each hose in the pair has a different spanner location to ease connection of the threaded end into the monobloc’s inlets.
The hoses are suitable for cold water up to 10 Bar and hot water (65˚C max) up to 6 Bar and approved by WRAS.
The Speedfit Connection, when made with the insert, has a number of design features.
Sliding the stem of the insert into the pipe gives greater compression of the main ‘O’ ring on the pipe and greater rigidity of the length of pipe within the fitting, reducing the chance of leaks if a side load is applied.
A connection is easier to make because the head of the insert has been designed for ease of insertion.
Superseal Inserts are listed on page 14.
08
09
PLUMBING FITTINGS
EQUAL STRAIGHT CONNECTOR
P
ART
N
O
.
PEM0410W
PEM0415W
PEM0422W
PEM0428W
S
IZE MM
10
15
22
28
Suitable for central heating systems.
REDUCING STRAIGHT COUPLER
P
ART
N
O
.
PEM201510W
PEM202215W
S
IZE MM
15 x 10
22 x 15
Suitable for central heating systems.
PE-COPPER COUPLER
P
ART
N
O
.
Used to connect PE Pipe to Speedfit or to Table X or Y Copper.
Taken from the Speedfit Underground Fittings
Range, see separate section for details and
Technical Specification.
JG601B
JG603B
JG602B
Cold water only.
S
IZE MM
20 x 15
25 x 15
25 x 22
EQUAL ELBOW
STEM ELBOW
Provides a swivel type connection.
P
ART
N
O
.
S
IZE MM
PEM0310W
PEM0315W
PEM0322W
PEM0328W
10
15
22
28
Suitable for central heating systems.
P
ART
N
O
.
P
IPE
S
TEM
PEM221010W
PEM221015W
PEM221515W
PEM222222W
10
10
15
22 x x x x
Suitable for central heating systems
Please note a Collet Cover cannot be used on a Speedfit end assembled with the stem of a 22mm Stem Elbow.
10
15
15
22
EQUAL TEE
P
ART
N
O
.
S
IZE MM
PEM0210W
PEM0215W
PEM0222W
PEM0228W
10
15
22
28
Suitable for central heating systems.
REDUCING TEE
Sizes are listed in the following order.
1 2
3
P
ART
N
O
.
PEM3015BW
PEM3015AW
PEM3022CW
PEM3022BW
PEM3022DW
PEM302210AW
PEM3022AW
PEM3028BW
PEM302815AW
PEM3028AW
PEM3028DW
S
IZE MM
Suitable for central heating systems.
15 x 10 x 10
15 x 15 x 10
15 x 15 x 22
22 x 15 x 15
22 x 15 x 22
22 x 22 x 10
22 x 22 x 15
28 x 22 x 22
28 x 22 x 28
28 x 28 x 15
28 x 28 x 22
STEM TEE
P
ART
N
O
.
S
IZE MM
PEM532210W
PEM532215W
22 x 22 x 10
22 x 22 x 15
Suitable for central heating systems.
Sizes are listed in the following order.
1 2
3
TANK CONNECTOR
P ART N O .
S IZE MM
CM0715S
CM0722S
CM0728S
15
22
28
Suitable for cold water tanks only.
Requires hand tightening only.
Maximum wall thickness of tank 4mm.
STOP END
P
ART
N
O
.
S
IZE MM
PSE4610W
PSE4615W
PSE4622W
10
15
22
Suitable for central heating systems.
REDUCER
P
ART
N
O
.
S
IZE MM
PEM061510W
PEM062215W
PEM062815W
PEM062822W
15 x 10
22 x 15
28 x 15
28 x 22
Suitable for central heating systems.
FEMALE COUPLER - TAP CONNECTOR
Requires hand tightening only.
P
ART
N
O
.
PSE3210W
PSE3201W
PSE3203W
PSE3202W
S
IZE
10mm x 1/2” BSP
15mm x 1/2” BSP
15mm x 3/4” BSP
22mm x 3/4” BSP
Suitable for central heating systems
Note: Plastic threads are not as strong as metal threads.
For torque figures see Technical Checklist.
STRAIGHT TAP CONNECTOR
With brass swivel nut and sealing washer.
P ART N O .
S IZE
PEMSTC1514
PEMSTC1516
PEMSTC2216
15mm x 1/2” BSP
15mm x 3/4” BSP
22mm x 3/4” BSP
Suitable for central heating systems.
For torque figures see Technical Checklist.
BENT TAP CONNECTOR
P
ART
N
O
.
PEMBTC1514
S
IZE
15mm x 1/2” BSP
Suitable for central heating systems.
For torque figures see Technical Checklist.
With brass swivel nut and sealing washer.
CONVERSION CONNECTOR
P
ART
N
O
.
S
IZE
NC471
NC2324
1/2 id x 15mm
3/4 id x 22mm
Suitable for central heating systems.
Connects imperial to metric pipe.
PLUG
P
ART
N
O
.
S
IZE MM
PL10
PL15
PL22
PL28
10
15
22
28
Suitable for central heating systems.
PLASTIC BACK PLATE ELBOW
P
ART
N
O
.
S
IZE
MM X BSP
15 x 1/2" 15PWB
Hot and cold water only, maximum 65ºc.
Protect from sunlight and frost.
MANIFOLDS
4 WAY MANIFOLD
4 PORT RAIL MANIFOLD
P
ART
N
O
.
S
IZE MM
SFM512210S 22 x 10
Suitable for central heating systems.
P ART N O .
S IZE MM
SFM522210S
SFM522215S
22 x 10
22 x 15
Suitable for central heating systems.
SLIP CONNECTOR
P
ART
N
O
.
S
IZE MM
CM-SC-15S 15
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
HOSE CONNECTOR
P ART N O .
NC448
NC473
NC737
S IZE
15mm x 1/2"
22mm x 3/4"
22mm x 1/2"
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
RADIATOR OUTLET PLATE
P
ART
N
O
.
JG- ROP
Creates a neat outlet for 10mm supply pipes to a radiator. To be used with single gang 25mm steel K0 boxes to BS 4662, fitted with rubber grommet.
BRASS RAIL MANIFOLD
P
ART
N
O
.
S
IZE
MM
JGRAIL4 4 Zone 22 x 15
JGRAIL6 6 Zone 22 x 15
JGRAIL12 12 Zone 22 x 15
BRASS MANIFOLD
Blanking plug supplied with each manifold.
Red Handle
Blue Handle
P ART N O .
S IZE
MM
JGMAN2-R 2 Port 3/4” x 15
JGMAN3-R 3 Port 3/4” x 15
JGMAN4-R 4 Port 3/4” x 15
JGMAN2-B 2 Port 3/4” x 15
JGMAN3-B 3 Port 3/4” x 15
JGMAN4-B 4 Port 3/4” x 15
Control knobs have the means to be labelled
ʻBasinʼ, ʻBathʼ, ʻSinkʼ, ʻShowerʼ, ʻToiletʼ, ʻBidetʼ or ʻWashing Machineʼ.
10
11
BRAIDED FLEXI HOSES
Not suitable for central heating systems.
Hot and Cold water only, 65°C max.
SPEEDFIT X UNION NUT
P
ART
N
O
.
150mm long
300mm long
FLX43P
FLX34P
FLX35P
FLX15P
FLX16P
FLX22P
500mm long FLX18P
FLX20P
FLX19P
FLX23 Full Bore
1000mm long FLX40
FLX42
FLX41
S
IZE
MM X BSP
15 x 1/2"
10 x 1/2"
15 x 3/8"
15 x 1/2"
15 x 3/4"
22 x 3/4"
15 x 1/2"
15 x 3/4"
22 x 3/4"
22 x 3/4"
15 x 1/2"
15 x 3/4"
22 x 3/4"
SPEEDFIT X SPEEDFIT
P
ART
N
O
.
300mm long
FLX33P
FLX17P
FLX26P
500mm long FLX21P
FLX27P
1000mm long FLX47
S
IZE MM
15 x 10
15 x 15
22 x 22
15 x 15
22 x 22
15 x 15
SPEEDFIT X MALE THREAD
P
ART
N
O
.
300mm long FLX49
S
IZE
MM X BSP
15 x 3/8”
SPEEDFIT X UNION NUT WITH SERVICE VALVE
P
ART
N
O
.
S
IZE
MM X BSP
300mm long
BRASS VALVE
FLX24P
FLX25P Full Bore
500mm long
FLX31P
FLX38P
FLX32P Full Bore
15 x 1/2”
22 x 3/4”
15 x 1/2”
15 x 3/4”
22 x 3/4”
PLASTIC VALVE
FLX37P
FLX39P
15 x 1/2”
22 x 3/4”
PLASTIC VALVE WITH HANDLE
FLX37-H 15 x 1/2”
FLX39-H 22 x 3/4”
SPEEDFIT X SPEEDFIT WITH SERVICE VALVE
S IZE MM
300mm long
500mm long
P ART N O .
BRASS VALVE
FLX44P
FLX45P
15 x 15
15 x 15
SPEEDFIT X PLAIN STEM
300mm long
P ART N O .
FLX53
P IPE
15
S TEM
15
ELBOW PATTERN
P
ART
N
O
.
300mm long FLX36P
S
IZE
MM X BSP
15 x 1/2”
FOR MONOBLOC MIXERS
P
ART
N
O
.
300mm long FLX48
FLX28
FLX29
S
IZE
MM X MALE
12 x M10
15 x M10
15 x M12
WHITE PVC FLEXI HOSES
Not suitable for central heating systems.
Hot and Cold water only, 65°C max.
SPEEDFIT X UNION NUT
P
ART
N
O
.
300mm long WFLX15
WFLX16
WFLX22
500mm long WFLX18
WFLX20
WFLX19
SPEEDFIT X SPEEDFIT
P
ART
N
O
.
300mm long WFLX17
S
IZE
MM X BSP
15 x 1/2”
15 x 3/4”
22 x 3/4”
15 x 1/2”
15 x 3/4”
22 x 3/4”
S
IZE MM
15 x 15
SPEEDFIT X PLAIN STEM
P
ART
N
O
.
200mm long WFLX51
P
IPE
15
S
TEM
15
ELBOW PATTERN
P ART N O .
300mm long WFLX36
S IZE
MM X BSP
15 x 1/2”
SPEEDFIT X UNION NUT WITH SERVICE VALVE
300mm long
P
ART
N
O
.
S
IZE
MM X BSP
PLASTIC VALVE WITH HANDLE
WFLX37-H 15 x 1/2”
WFLX39-H 22 x 3/4”
FOR MONOBLOC MIXERS
P
ART
N
O
.
300mm long WFLX28
WFLX29
S
IZE
MM X MALE
15 x M10
15 x M12
IDENTITY DISCS
P ART N O .
FLX - RED
FLX - BLU
P ACK Q TY
10
10
For handles on service valves.
BRASS FITTINGS
BRASS MALE COUPLER
P
ART
N
O
.
S
IZE
MM X BSPT
MW011504N BRASS
MW012206N BRASS
MW012808N
P
ART
N
O
.
15 x 1/2”
22 x 3/4”
28 x 1”
S
IZE
MM X BSP
10MC (1/2) BRASS
15MC (1/2) BRASS
22MC (3/4) BRASS
MW012818N
10 x 1/2”
15 x 1/2”
22 x 3/4”
28 x 1”
Suitable for central heating systems.
Manufactured in DZR Brass.
BRASS BACK PLATE ELBOW
P ART N O .
15WB
22WB
S IZE
MM X BSP
15 x 1/2"
22 x 3/4"
Manufactured in DZR Brass.
Suitable for central heating systems.
SHORT VERSION
15WB2 15 x 1/2"
Manufactured in Brass.
Suitable for central heating systems.
BRASS MALE STEM ADAPTOR
P ART N O .
Converts Speedfit to male thread.
MW051504N
MW052206N
MW052818N
S IZE
MM X BSPT
15 x 1/2”
22 x 3/4”
28 x 1” BSP
Suitable for central heating systems.
Manufactured in DZR Brass.
BRASS FEMALE STEM ADAPTOR
P
ART
N
O
.
Converts Speedfit to female thread.
S
IZE
MM X BSP
MW501514N
MW502216N
15 x 1/2”
22 x 3/4”
Suitable for central heating systems.
Manufactured in DZR Brass.
BRASS MALE CYLINDER ADAPTOR
P ART N O .
S IZE
MM X BSP
22 x 1 22CMA
Suitable for central heating systems.
Manufactured in DZR Brass.
BRASS FEMALE CYLINDER ADAPTOR
P
ART
N
O
.
S
IZE
MM X BSP
22 x 1 22CFA
Suitable for central heating systems.
Manufactured in DZR Brass.
12
VALVES
STOP VALVE
BRASS STOP TAP
P
ART
N
O
.
15STV
22STV
S
IZE MM
15
22
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
P
ART
N
O
.
S
IZE MM
15BSC 15
Only suitable for central heating.
Head and Body manufactured in DZR Brass.
WASHING MACHINE TAP
P
ART
N
O
.
15 APT
S
IZE
15mm x 3/4" BSP
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
For torque figures on plastic threads please see Technical Checklist.
EMERGENCY SHUT OFF TAP
P
ART
N
O
.
15 ESOT
S
IZE MM
15
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
DOUBLE CHECK VALVE
P ART N O .
15DCV
S IZE MM
15
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
13
BRASS DRAIN COCK
PLASTIC SERVICE VALVE
P ART N O .
S IZE MM
15BDC 15
Suitable for central heating systems.
Manufactured in DZR Brass.
Please note a collet cover cannot be used on a Speedfit end assembled with a draincock.
Draincocks can be fitted with a standard fitting fitted with a collet clip.
When using with Twist and Lock Fittings the fitting must be locked.
P
ART
N
O
.
15SV
22SV
S
IZE MM
15
22
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
PLASTIC SERVICE VALVE WITH TAP CONNECTOR
Grey
P
ART
N
O
.
S
IZE
15SVSTC 15 x 1/2”
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
P ART N O .
S IZE
15SVSTC-W 15 x 1/2”
Not suitable for central heating systems.
White Hot and Cold water only, 65°C maximum.
PLASTIC ANGLE SERVICE VALVE
WITH TAP CONNECTOR
Grey
P
ART
N
O
.
S
IZE
15SVBTC 15 x 1/2”
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
White
P
ART
N
O
.
15SVBTC-W
S
IZE
15 x 1/2”
Not suitable for central heating systems.
Hot and Cold water only, 65°C maximum.
BRASS SERVICE VALVE
P
ART
N
O
.
S
IZE MM
15HSV-BRASS 15
Suitable for central heating systems.
BRASS CHROME PLATED SERVICE VALVE
P
ART
N
O
.
S
IZE MM
10HSV
15HSV
22HSV
10
15
22
Suitable for central heating systems.
BRASS CHROME PLATED SERVICE VALVE
WITH TAP CONNECTOR
P
ART
N
O
.
S
IZE
15PTSV
22PTSV
15 x 1/2”
22 x 3/4”
Suitable for central heating systems.
BRASS CHROME PLATED BALL VALVE
P
ART
N
O
.
S
IZE MM
10BV
15BV
22BV
10
15
22
Suitable for central heating systems.
Each Valve has a red and a blue indice.
PLASTIC BALL VALVE
P ART N O .
15SV-H
22SV-H
S IZE MM
15
22
Not suitable for central heating systems.
Each Valve has a red and a blue indice.
PIPE AND PIPE ACCESSORIES
PEX BARRIER PIPE
Coils
The pipe has an inner barrier to stop the ingress of atmosphere.
British Gas accepted for water pipe in vented and sealed central heating systems.
P
ART
N
O
.
10BPEX-25C
10BPEX-50C
10BPEX-100C
15BPEX-25C
15BPEX-50C
15BPEX-100C
15BPEX-120C
15BPEX-150C
22BPEX-25C
22BPEX-50C
Suitable for central heating systems.
S
IZE
10mm x 25m
10mm x 50m
10mm x 100m
15mm x 25m
15mm x 50m
15mm x 100m
15mm x 120m
15mm x 150m
22mm x 25m
22mm x 50m
PEX BARRIER PIPE
Straight lengths
The pipe has an inner barrier to stop the ingress of atmosphere.
*By special order only.
P
ART
N
O
.
S
IZE
15BPEX-20x2L
15BPEX-20x3L
15BPEX-20x6L
22BPEX-20x2L
22BPEX-20x3L
22BPEX-20x6L
28BPEX-10x3L
28BPEX-10x6L
15mm x 2m
15mm x 3m
15mm x 6m
22mm x 2m
22mm x 3m
22mm x 6m
28mm x 3m
28mm x 6m
*
Suitable for central heating systems.
POLYBUTYLENE BARRIER PIPE
Coils
The pipe has an inner barrier to stop the ingress of atmosphere.
British Gas accepted for water pipe in vented and sealed central heating systems.
P
ART
N
O
.
15BPB-25C
15BPB-50C
15BPB-100C
15BPB-120C
15BPB-150C
22BPB-25C
22BPB-50C
S
IZE
15mm x 25m
15mm x 50m
15mm x 100m
15mm x 120m
15mm x 150m
22mm x 25m
22mm x 50m
Suitable for central heating systems.
SUPERSEAL PIPE INSERT
To be used only when connecting
Speedfit Pipe and Speedfit Fittings to enhance the sealing security of the connections. See page 05.
P ART N O .
STS10
STS15
STS22
STS28
S IZE MM
10
15
22
28
Suitable for central heating systems.
PIPE INSERT
To be used when connecting Speedfit Pipe to a compression fitting.
See Page 16.
P ART N O .
S IZE MM
TSM10N
TSM15N
10
15
TSM22N 22
TSM28N 28
Suitable for central heating systems.
CONDUIT PIPE
To be used when Speedfit Pipe is laid in Concrete and Masonry, see section on page 20.
P
ART
N
O
.
BLACK
15BLK CON-25C
15BLK CON-50C
22BLK CON-25C
22BLK CON-50C
RED
15RED CON-50C
22RED CON-50C
BLUE
15BLU CON-50C
22BLU CON-50C
S
IZE
15mm x 25m
15mm x 50m
22mm x 25m
22mm x 50m
15mm x 50m
22mm x 50m
15mm x 50m
22mm x 50m
PIPE IN PIPE
P
ART
N
O
.
15PIP-50C-E
22PIP-50C-E
S
IZE
15mm x 50m
22mm x 50m
CONDUIT ELBOW
P
ART
N
O
.
CONELB
S
IZE
FITS 10, 15 & 22mm
COLLET COVER
Available in white, red or blue
P
ART
N
O
.
S
IZE MM
PKM1910W
PKM1910R
PKM1910B
AM1915W
PM1915R
PM1915B
AM1922W
PM1922R
PM1922B
Suitable for central heating systems
15
15
22
22
22
10
10
10
15
COLLET LOCKING CLIP
Grey
Red
White
Blue
P
ART
N
O
.
CM1810S
CM1815S
CM1822S
CM1810W
CM1815W
CM1822W
S
IZE MM
10
15
22
10
15
22
CM1810R
CM1815R
CM1822R
CM1810B
CM1815B
CM1822B
10
15
22
10
15
22
Suitable for central heating systems.
White and grey collet clips prevent accidental release of pipe from standard fittings.
Red and blue clips provide colour coding of pipe, they should not be used to prevent accidental release of pipe.
14
PIPE AND PIPE ACCESSORIES
RELEASE AID
P
ART
N
O
.
10RA
15RA
22RA
28RA
S
IZE MM
10
15
22
28
Allows a firmer grip on the collet when removing pipe.
COLD FORMING BEND
P
ART
N
O
.
10CFB
15CFB
22CFB
10mm
S
IZE MM
10
15
22
15mm and 22mm
To help create a tighter bend than the minimum with unsupported pipe.
BENDING SPRING
P
ART
N
O
.
JG-BS10
JG-BS15
JG-BS22
S
IZE MM
10
15
22
PIPE CUTTER
For up to 22mm size pipe.
P
ART
N
O
.
JG-TS
HEAVY DUTY PIPE CUTTER
P
ART
N
O
.
JG HDC
BLADE-JGHDC
15
For up to 28mm size pipe.
PIPE CLIPS AND SPACERS
P
ART
N
O
.
PC15W
PC22W
PC28W
PCSW
NAIL CLIP
P
ART
N
O
.
NPC10
NPC15
NPC22
NPC28
FOIL TAPE
P
ART
N
O
.
JGTAPE
S
IZE MM
10
15
22
28
S
IZE MM
15
22
28
S
IZE MM X M
50 x 45
Metallic tape to meet NHBC requirements for plastic pipe to be detected inside walls.
PLUMBING SPARE PARTS
COLLETS
For Standard Fittings
For Twist and Locks Fittings
P
ART
N
O
.
PXC 10
PXC 15
SPF 22
PXC 28
PXC 10
PXC 15
PXC 22
PXC 28
10
15
22
28
S
IZE MM
10
15
22
28
EPDM ‘O’ RING
P
ART
N
O
.
10 EPR
15 EPR
22 EPR
28 EPR
S
IZE MM
10
15
22
28
THREAD WASHER
P
ART
N
O
.
1/2 EPW
3/4 EPW
S
IZE
1/2
3/4
For use with Female Coupler/Tap Connector.
SYSTEM CONNECTIONS
CONNECTION TO COMPRESSION FITTING
Many but not all compression fittings are suitable for use with plastic fittings and pipe. Users should therefore check for compatibility. Compression fittings with short tube stop depth or brass olives should not be used with plastic fittings or pipe.
When using compression fittings with Speedfit Pipe, a
Standard Pipe Insert (prefix TSM) must be used to withstand the compressive pressure of the olive. The olive must be located within the the length of the pipe insert and the pipe fully inserted into the fitting. The connection should not need more than 2 full turns after the olive has gripped the pipe. JG Speedfit recommend the use of soft copper olives.
Ensure nut and olive are in place before inserting pipe insert.
Compression fitting Standard Pipe insert
Olive Speedfit Pipe
CONNECTION TO IMPERIAL PIPE AND FITTINGS
The Speedfit Range includes couplers to connect
Speedfit Pipe to 1/2” to 1” BSP and BSPT. See page 12.
Fittings to connect imperial pipe to metric pipe are shown on page 10.
CONNECTION TO CHROME-PLATED COPPER PIPE
Speedfit fittings can be connected onto chromium plated copper pipe if the chromium plating is completely removed to the full depth of the fitting. To ensure maximum grip, the fitting of a collet clip is recommended.
It is not possible to connect Speedfit fittings to Stainless
Steel Pipe.
Collet clip
CONNECTION TO MAINS SUPPLY
In modern properties, water enters a building usually in blue MDPE (medium density polyethylene) pipe. In order to comply with Water Regulation Schedule 2.10, the internal plumbing system should be connected via a
Speedfit Stop Valve (Part Nos. 15STV and 22STV) in conjunction with a PE-Copper Coupler from the Speedfit range of Underground Fittings.
Speedfit Pipe with Superseal Pipe Insert
Stop valve
Copper pipe
PE copper coupler
MDPE pipe with
Pipe Insert
Connection of Speedfit pipe to supply pipe of other materials should be via a stop tap with a 15mm or
22mm compression outlet.
CONNECTION TO RING MAINS
Water-replenishing ring mains are typically used in hotels and hospitals. They are maintained at a constant high temperature to supply hot water to distribution pipes to wards or hotel rooms which may be some way from the heat source.
These systems are very different from more conventional domestic hot water and central heating systems.
Speedfit Products cannot be used on ring main systems.
The exception would be those systems designed for domestic situations which have an intermittent temperature of less than a maximum of 65ºC. This is in accordance with BS7291 Parts 1 and 3 Class S.
CONNECTION TO BOILERS
Speedfit pipe should never be connected directly to a boiler.
Although most modern boilers have a high limit thermostat, residual heat can be conducted by the heat exchanger. Therefore, Speedfit recommend a minimum of
1 metre from the boiler casing should be run in copper pipe unless otherwise stated in the boiler manufacturers installation literature.
A gravity primary circuit operating on an uncontrolled cooking range or solid fuel boiler should be run entirely in copper and the heating circuit run in copper for the first metre.
Refer to BS 5955: Part 8 for further clarification.
All appliances should have safety devices to make sure they cannot operate above the working temperature and pressure range set out in our Technical Checklist on page
29. If safety devices are not incorporated within the appliance then external controls will be needed.
Water meters (and other devices) can contain check valves that prevent the expansion of heated water back down the main supply from a combi boiler. If plastic pipe is to be used, a suitable expansion vessel must be fitted.
This is especially important to consider if a water meter is fitted retrospectively. Speedfit do not recommend the use of plastic pipe on the main supply between a water meter and a combi boiler if an expansion vessel is not fitted.
Speedfit Products should not be fitted to a sealed system oil boiler, back fired boiler or other uncontrolled heat source.
Please also see Drop-Pipe Systems on page 17 and
System Commissioning and Flushing on page 21.
CONNECTING TO OTHER PLUMBING FIXTURES
As shown in the Product Range List, the Speedfit range of fittings includes valves, taps, adaptors and connectors for the plumbing of all typical domestic appliances and fittings.
CONNECTION TO CYLINDER & WATER HEATERS
Speedfit can be used on sealed and open vented heating systems, where boilers are either heating a hot water storage cylinder or instantaneous hot water such as a combination boiler. The temperature and pressure limits of the system must not exceed the maximum values stated under the heading ‘Working Temperatures and Pressures’.
When using a traditional copper vented cylinder Speedfit pipe and fittings can be installed with direct connections to the cylinder.
16
17
CONNECTION TO CYLINDER & WATER
HEATERS CONTINUED
Unvented pressurised cylinders can be installed using
Speedfit Pipe and Fittings. However, insertion depths on compression joints that form part of the cylinder must be checked prior to installation and the use of standard pipe inserts (Prefix TSM) is recommended.
In accordance with current U.K. Building Regulations
(Part G), discharge pipes from temperature and/or pressure relief valves must be run in metal pipework.
Speedfit connections to combined Cylinder/Boiler units and Thermal Storage Units must be made outside the casing unless otherwise stated in manufacturers installation literature.
DROP-PIPE SYSTEMS
Care should be taken when designing and installing a central heating system where radiators are supplied by pipe work which drops from an upper floor.
With this kind of system it is possible to trap air in the upper floor pipe work. When the boiler is fired the increase in pressure within the pipe caused by expanding air could cause the pipe to burst.
It is therefore essential that the system be designed so that any air can be removed from the system either automatically or manually by installing automatic or manual air vents at the highest points of the system.
DISCHARGE PIPES
Speedfit pipe should not be used to provide the discharge from unvented cylinders, unvented water heaters and sealed systems via the temperature relief and pressure relief values.
CONNECTION TO COPPER PIPE
The minimum distance to make a solder connection on copper pipe inserted into a Speedfit Fitting is 450mm
(18 inches). Ensure that any residual flux solder is not allowed to come in contact with the fitting. That same measurement is the safe distance to use a freezer kit to
Speedfit Pipe.
CONNECTING TO COLD WATER STORAGE TANK
To install the Speedfit Tank Connector, unscrew the nut and push the body of the fitting through the tank hole with the washer on the inside of the tank.
Hand tighten the nut onto the body. Push the pipe into the connector.
Note: Hand tightening the nut onto the body is all that is required. Further mechanical tightening will damage the fitting.
Maximum wall thickness of tank 4mm
Cold water tank
Hole dia.
15mm pipe
22mm pipe
28mm pipe
29mm
36mm
46mm
Washer
CONNECTION TO PUMPS AND VALVES
Speedfit pipe should be connected to circulating pumps, motorised valves in accordance with the section in this book headed, “Connecting Plastic Pipe To Compression
Fittings”. If Speedfit pipe is not mounted on a supporting structure, the pipe must be clipped close to the components’ connections to ensure adequate support and to assist in the reduction of vibration.
For heavier equipment, ensure that appropriate metal brackets provide full and independent support of the components and that it does not rely solely on the pipework for support.
WATER HEATERS
Speedfit recommend that mains supply pipework to unvented water heaters (up to 15ltr capacity), be run in metal pipes.
UNVENTED PRESSURISED CYLINDERS
Unvented Pressurised Cylinders can be installed using
Speedfit pipe and fittings. However if the safety parameters of the cylinder exceed those of the pipe and fittings it is possible to fit a pressure reduction valve on the out going hot supply pipe. This will not interfere with any other cylinder safety devices demanded by regulations as they are all fitted in the incoming side of the cylinder. Run a short length of copper pipe from the cylinder connection (about 150mm - 300mm) then fit a
Honeywell DO5F pressure reduction valve. This will protect the pipe and fittings from excessive pressure in the event of boiler / cylinder malfunction. The factory fitted temperature / pressure relief valve on the cylinder will discharge below 100˚C therefore protecting the pipe from excessive temperature.
PREVENTING BACK FLOW
The Speedfit range includes a Double Check Valve
(Part No 15DCV) to enable installers to comply with Water
Regulation Schedule 2.15, thus preventing contamination o f w a t e r a r i s i n g f r o m back siphonage, backflow or cross connection.
RADIATOR CONNECTIONS
The most common way of running pipework to a radiator is to run both flow and return pipes central to the radiator position.
The pipes exit a single gang box (fitted with rubber grommets) located at the mid height of the finished radiator position. This also provides a fixed point for other trades to work to and reduces the risk of damage to the pipework.
Once the plasterboard is installed the pipes are passed through the Speedfit Radiator Outlet Plate to exit plasterboard without the need of unsightly holes.
Metal reducing sets which convert radiator valves from
15mm to 10mm are not suitable for use with Speedfit
Fittings or Pipe as they can cause damage to the plastic.
ELECTRICAL CONTINUITY
The plumbing or heating system installer should have these aspects checked to ensure compliance with current
IEE regulations. If in doubt please contact the Speedfit
Technical Advisory Service or your local Electricity Authority.
ELECTRICAL CONTINUITY CONT’D
IEE Guidance Note 7 provides useful guidance on the design of electrical installations where there is increased risk of electric shock. It recognises that the requirement for supplementry bonding may be relaxed where metal taps and plastic pipes supply other bathroom fittings.
Similarly a metal bath or radiator not connected to an extraneous-conductive-part is not required to be connected to the local supplementry conductors.
INSTALLING PIPEWORK
SPEEDFIT BARRIER PIPE
Speedfit Barrier Pipe is manufactured to BS 7291 Parts 1,
2 and 3 Class S and is Kitemarked.
It is made up of 5 layers, the centre of which is a blue coloured oxygen barrier which prevents the ingress of air into the system, thereby reducing the effect of corrosion on metal components.
Metal
Pipe
Clip
Earth Lead
Speedfit Pipe and Fitting
Clip
Metal
Pipe
SUPPLEMENTRY BONDING TO BATHROOMS
Pipe
Material
Cold Hot Central
Water Water Heating
Supplementary Bond Comments
Required Between
P
P
P
M
M
P
M
P
M
M
P
M
M
M
P
Earth terminals of protective conductors of class I and of class II equipment and accessible exposed conductive parts of the building structure.
Bonding of metal taps metal radiatorsor metal baths is not required unless the bath is connected to the metallic building structure.
Hot water pipe, central heating pipes, earth terminals of protective conductors of class I and class II equipment and accessible exposed conductive parts of the building structure.
Central heating pipes, the earth terminals of protective conductors of class I and class II equipment and access to exposed conductive parts of the building structure.
A bond is not required to the taps either hot nor cold, or to metal baths unless connected to the metallic building structure.
Bonding of metal water taps is not required, nor metal baths unless connected to the metallic building structure.
All metal pipes, earth terminals of protective conductors class I and class II equipment, and accessible exposed conductive parts of the building structure.
Metal pipes themselves can be used as bonding conductors if joints are metal to metal and electrically continuous.
All metal pipes, earth terminals of protective conductors of class I and class II equipment, and accessible exposed conductive parts of the building structure.
Metal central heating radiator does not require bonding.
P = Plastic M = Metal NB: All Waste Pipes are plastic.
1. Supplementary bonding is carried out to the earth terminal of protective conductors of class I and class II equipment within the bathroom. A supplementary bond is not run back to the main earth.
2. Metal window frames are not required to be supplementary bonded unless they are electrically connected to the metallic structure of the bonding.
3. Metal baths supplied by metal pipes do not require supplementary bonding if all the pipes are bonded and there is no other connection of the bath to earth.
4. All bonding connections must be accessible and labelled
“Safety Electrical Connection - Do Not Remove”.
Because of it’s low thermal conductivity, when carrying hot water, Speedfit Pipe is cooler and therefore safer to touch. Relatively low heat loss through radiation means that a system retains it’s heat longer and delivers hot water more quickly and with less wastage than a metal system.
22mm Barrier-PB to BS7291-2 2001 Class S 12 BAR 20°C - 4 BAR 82°C - 3 BAR 92°C
15mm B-PEX to BS7291 : Part 3 : 1990 Class S 12 BAR 20°C - 4 BAR 82°C - 3 BAR 92°C
The pipe is available in coils and straight lengths. See pages 14. Pipe markings are spaced to aid the making of a good connection when using a Superseal Pipe Insert.
PIPEWORK SIZING
For general guidance on pipework sizing, please refer to
BS6700 or the Institute of Plumbing Engineering Services
Design Guide. Speedfit fittings are suitable for pipes within ±0.1mm of nominal size. They can be used with copper pipe to BS EN 1057 or Speedfit plastic pipe.
The Product Range List shows the fittings available for reducing pipe diameters within the system.
Speedfit pipe is available in straight lengths and coils.
Straights
Coils
2m
3m
Pipe Diameter
-
-
15mm 22mm -
15mm 22mm 28mm
6m 15mm 22mm 28mm
25m 10mm 15mm 22mm -
50m 10mm 15mm 22mm
100m 10mm 15mm -
-
-
120m
150m
-
-
15mm
15mm
-
-
-
-
METAL FOIL TAPE
JG Speedfit aluminium foil tape can be used to fulfil the
NHBC requirements for the identification of location of plastic pipes in or behind a wall surface by a metal detector. It features a bright aluminium finish, rubber/resin high-tack adhesive and quality siliconised backing paper to allow the easy handling of short, cut lengths.
O N OT sttiic k tth os e o ny ap e tto e S pe uffa cttu piip e o s
18
19
PIPE BENDING
Gentle bends can be made with pipe clips on either side of the curve, positioned to maintain the bend radius.
Tighter bends can be achieved by using the cold forming bends shown on page 15.
Internal Bending Springs are available in 10mm to 22mm sizes, see page 15.
It is also possible to bend Speedfit Pipe using a standard pipe bender. The pipe should not be heated with a blowlamp or hot air gun.
Minimum bend radii for Speedfit pipe are as follows:
Min Radius Pipe Diameter
10mm 15mm 22mm 28mm
with Cold Forming Bends 30mm 75mm 110mm with Clips
-
100mm 175mm 225mm 300mm
For bends of radii smaller than those shown, standard elbow fittings are recommended.
PIPE SUPPORT AND CLIPPING
There are two types of pipe clip in the Speedfit range.
Firstly, a nail clip is used for fixing to timber when running concealed pipe work i.e.
underfloor or in a roof space . This clip takes less time to fit and is compact which allows pipework to be fixed close together when space is at a premium.
The second type uses a screw and therefore takes a little longer to fix. When pipes are required to cross over, it is possible to add a spacer to the clip. This will give room between the pipe and the wall to allow the pipes to cross over. If pipework needs to be insulated, using the spacer will give room for the lagging to be applied.
Pipe clips should not be fitted any closer than 60mm from the end of the fitting to allow for expansion. Pipes should always be adequately supported to prevent undue stress or side load on the fittings.
RECOMMENDED CLIP SPACING
For surface mounted pipes
Pipe Diameter
10 - 15mm
22mm
28mm
Clip Spacing
Horizontal Run Vertical Run
300mm
500mm
800mm
500mm
800mm
1,000mm
PIPE SIZING
For general guidance on pipework sizing, please refer to
BS6700 and BS5449 or the Institute of Plumbing
Engineering Services Design Guide. Speedfit fittings are suitable for connection to pipe sizes within ± 0.1mm of nominal size.
The maximum heat carrying capacity and flow of Speedfit pipe, based on 1.2m/s velocity and an 11ºC temperature drop is shown in the table below.
Pipe size Max Capacity Max Flow
KW litres/sec
10mm
15mm
1.948
5.941
0.042
0.129
22mm
28mm
13.604
21.991
0.295
0.478
Headloss m/m pipe
0.283
0.139
0.084
0.062
PIPEWORK INSULATION
The insulation requirements for Speedfit pipe are the same as those for copper and should comply with BS6700 and BS5422.
CONCEALED PIPEWORK
The flexibility of Speedfit pipe gives it the ability to be threaded through concealed or inaccessible spaces without disruption to surrounding structures, making major savings in installation time.
Pipework can be “cabled” through drilled holes in joists and rafters. Therefore, pipework can be installed after floorboards have been laid, working below the floor before the ceiling is installed.
This makes site work far safer as the installer does not have to balance on open joists with the risk of dropping tools or equipment on other people below.
Joist Speedfit pipe
Clips
This will also eliminate the risk of damage by floorboard nails. There is no need for dry runs since pipe can be cut and connections made in-situ.
Rigid pipe, such as copper, can only be fed under floor in short lengths. However, Speedfit pipe, being flexible, can run from one fitting to another without having to install a connector in between.
Speedfit needs no jointing materials, eliminating the risk of fire from the use of a blowlamp, solder and flux
.
TRADITIONAL JOISTS
Instructions on the drilling of joists is given in the Building
Regulations Approved Document A, and summarised as follows:
1. Holes should be no greater than 0.25 of the depth of the joist.
2. Holes should be drilled at the neutral axis.
3. Holes should not be less than 3 diameters (centre to centre) apart.
4. Holes should be located between 0.25 and 0.4 times the span from the support.
Min 3 x hole dia.
D
Max. dia. of holes = 0.25D
TIMBER I BEAM JOISTS
Several types of joists are available and Speedfit recommends that specific manufacturers details are consulted.
However, the following can be used for general guidance.
• Holes may be located vertically anywhere in the web, but leave 3mm web at the top and/or bottom of hole.
Do not cut into joist flanges when cutting the web.
• If more than one hole is to be cut in the web, the distance between the edges of the holes must be at least 2x diameter of the largest hole.
• Generally joists are manufactured with 38mm perforated knockouts in the web at approximately
300mm centres along the length of the joist.
CROSS WEB JOISTS
Unlike I beam joists, pipe can be cabled anywhere within the open Web as no drilling is required. However, the top and bottom flanges must not be notched. Avoid damaging the outside diameter of the pipe as you cable through the metal cross web members
.
TIMBER FRAMED CONSTRUCTION
Speedfit is well suited for timber frame construction.
Ensure that the structural integrity is not compromised when installing the pipework.
If the pipe passes through an external wall, care must be taken not to damage the vapour barrier and should be installed on the inside of the thermal insulation layer.
If this is not possible, the use of conduit should be specified at the design stage.
STEEL FRAMED CONSTRUCTION
Speedfit is well suited for steel frame construction and care should be taken when installing the pipework.
All runs should be installed through preformed holes in the structure and protected by a rubber or plastic grommet.
Where clipping of pipework is restricted, cable ties may be used to secure the pipe.
As with all installations, make sure that any pipework passing through walls and floors does not affect the fire resistant properties of the structure.
DRY LINED WALLS
Speedfit pipework can be easily cabled through studwork and within wall systems as well as behind “dot and dab” plasterboard installations. Speedfit 10mm Barrier Pipe is most commonly used to feed radiators.
If incorporating fittings in this way, collet covers or collet clips must be used with the
Standard range of fittings.
WET PLASTER
To prevent surface damage to the plaster caused by expansion and contraction of Speedfit pipes, it is important to ensure that all Speedfit pipework is channelled into the wall and protected with appropriate sleeving. Alternatively, the pipework can be surface mounted and boxed in if required for aesthetic appearance.
LAYING OF PIPE IN CONCRETE AND MASONRY
Speedfit pipe and fittings can be laid in concrete and masonry providing they are installed in conduit pipe with access boxes for the fittings. As stated in Water
Regulation Schedule 2.7 and BS 8000 : Part 15, fittings and pipe should be removable for possible replacement.
Insulation is also recommended to protect against heat loss and the effects of frost.
Speedfit Conduit Pipe is supplied in either 15mm or 22mm in coil lengths of 25m or 50m. The flexible convoluted pipe has an outside diameter of 24mm and 30mm.
EXPOSED PIPEWORK
On long exposed runs of pipework, the expansion of
Speedfit pipe when warm (1% on length between 20 to
82°C) can cause it to sag between clip fixings. When this is undesirable, pipework can be boxed in or replaced with rigid copper pipe. Speedfit pipe and fittings are stabilised to withstand limited exposure to ultra-violet radiation in sunlight but are not designed for permanent direct exposure. Under such conditions painting or lagging is required. Pipe and fittings should also be lagged to prevent frost damage.
CHEMICAL EFFECTS
Only water or oil based paints should be used. Do not allow Speedfit fittings to come into contact with cellulose based paints, paint thinners or strippers, solder flux or acid based descalents or aggressive cleaning products. If there is a risk of any chemical treatments coming into contact with Speedfit, please contact the Technical Advisory
Service first to check compatibility.
FLUXES AND SPEEDFIT
JG Speedfit does not recommend that fluxes of any type come into contact with our pipe and fittings. However, if fluxes are to be used in an environment where Speedfit is installed then we recommend installers use non-acidic and zinc chloride free fluxes such as Fernox Flux.
ACOUSTIC
Properly installed, Speedfit pipes are virtually silent in operation and do not resonate; they absorb the acoustic vibrations and pressure waves created by cavitations, water hammer, float operated valve oscillation and other hydraulic effects. The inherent flexibility of Speedfit pipe effectively eliminates these troublesome problems, including those that occur when, due to thermal expansion, metal pipes rub against structural members and where long, straight runs of rigid pipe amplify water borne noise.
20
21
PROTECTION AGAINST RODENTS
When used in locations vulnerable to rodent attack, all plastic pipes and fittings should be adequately protected within sealed ducts.
Speedfit products along with other materials such as electrical cables may be damaged if rodents are present.
If vermin infestation is suspected then a rodent exterminator should take appropriate action
.
BIOLOGICAL
No taste, colour, odour or toxicity is imparted to water by
Speedfit components, nor do they promote microbiological growth.
In accordance with BS7291: Part 1 Clause 6.7, the opacity of both pipes and fittings allows insufficient light to pass for the growth of algae
Tests within the Water Regulations Advisory Scheme, have approved Speedfit pipe and fittings to BS 6920 for water quality.
SYSTEM TESTING
On completion of the plumbing and heating system it is essential that system checking and a hydraulic wet test takes place. Connections to boilers, radiators and sanitary ware should first be capped or plugged.
Testing should be carried out at
2 bar for 10 minutes followed by 10 bar for 10 minutes.
This testing combined with other relevant checks, should reveal most system problems. Any components within the system not designed to take these pressures should be disconnected.
Before carrying out a pressure test ensure all Speedfit pipe and fittings are installed correctly. Speedfit
Barrier Pipe is printed with insertion marks to help ensure full insertion has been achieved.
Remember pressure testing is NOT a substitute for making sure fittings are clean and free of any grit, dirt or swarf and the pipe is correctly inserted (see Making a
Good Connection, on page 06.
SYSTEM COMMISSIONING AND FLUSHING
With existing systems, flushing prior to the use of Speedfit is essential to remove any harmful contamination or chemical residues from elsewhere in the system.
For the installation of central heating systems flushing procedures must be in line with BS7593 code of practice for treatment of water in domestic hot water heating systems.
Flux residues used in the soldering of capillary fittings are very corrosive. Dirt and grit, which can enter the system when Speedfit pipe is being pushed through underfloor or across a roof space, must be removed.
During the commissioning of a heating system, all air must be removed from the system before the boiler is allowed to fire. This will ensure pockets of air do not cause localized overheating within the system as this could have a detrimental affect on the pipework and boiler.
For further advice on chemical flushing agents and inhibitor treatments, the following manufacturers should be contacted: Fernox Manufacturing Ltd., 01799 550811 or Sentinel Betz Dearborn Ltd., 0151 420 9595.
TECHNICAL ADVISORY SERVICE
The JG Speedfit Technical Advisory Service is available to assist and advise on all aspects of using the Speedfit system. The service is available between 8.00am and 4.30pm,
Monday to Friday on Telephone No. 01895 425333 and
Fax No. 01895 425350. Products within this Product Guide are designed for use within UK plumbing and heating installations or in other countries where similar installation requirements apply. For information on products suitable for use in other countries please consult our Technical
Advisory Service.
We take pride in the quality of our products and all complaints are investigated thoroughly. If you have a problem with a
Speedfit Product please return both fitting and pipe to us for investigation. We will need at least 50mm of pipe to ensure an accurate analysis. If there is a suspicion that the pipe is faulty, please provide marking details from the pipe.
COMMON PROBLEMS AND IDENTIFICATION
Problem:
Burst or melted pipe.
Pipe will be distorted showing either a ‘Parrot beak’ look or a long opening with the edges of the pipe melted in a wave shape.
Identification:
A ‘Parrot beak’ will have been formed by the pipe bursting due to the water freezing. If the Pipe has a melted appearance it will have been subject to a temperature in excess of 128 degrees Celsius. This will have been caused by direct contact with a heat source such as a blowtorch or flue pipe or by water or steam within the system rising above safety levels.
Problem:
A fitting or part of a fitting dissolved - the fitting may have blown off the pipe and may have missing component parts.
Identification:
The fitting will have failed because of a chemical attack. The most common attack is from acid based solder flux running down into the fitting during soldering of a nearby copper fitting or flux coming into contact with the fitting in some other way.
Problem:
Weep from fitting.
Identification :
The pipe has not been fully inserted up to the pipe stop or one or both of the ‘O’ rings have been damaged by burrs or sharp edges on the end of pipe. See
‘What Not to Do’ on page 06.
Problem:
The fitting has blown off the pipe. Fitting is missing the collet, the pipe insert is still inside the fitting after the pipe has come out.
Identification:
If this happens on first fix, the most likely reason is that the pipe has not been fully inserted into the fitting, up to the pipe stop, and the system has not been pressure tested.
If the collet (gripping device) is missing everything will blow out. If the collet is there and the pipe support is still inside the connector but the pipe has still blown out, this means that full insertion had not been accomplished.
UNDERFLOOR HEATING
The Speedfit Underfloor Heating System has been designed to be as quick and easy as possible to install with component parts manufactured to UK and European standards.
Underfloor heating provides the most comfortable even warmth of any heating system. It is economical to run and virtually maintenance free. The principle has been with us since
Roman times but is still the system of choice in some
European countries, accounting for 70% of installations.
The Speedfit System has water being pumped from a boiler to a pump pack, where it is mixed to approximately
50ºC then distributed via a manifold to heating circuits made using Speedfit Barrier Pipe. The pipe is laid in concrete or suspended just below the surface of the floor.
In concrete floors, the pipe is laid on insulation and then covered with a screed on which can be laid almost any type of floor covering.
For timber floors, spreader plates are laid between the joists and the floor decking or on the underside of the floor.
Speedfit Pipe is pushed into the grooves on the plates.
The floor area is typically warmed to between 25ºC and
28ºC, providing an even distribution of heat at only slightly higher than room temperature. The system is controlled by one or more thermostats which signal the Pump Pack when heat is required.
UNDERFLOOR HEATING SYSTEM
An Underfloor Heating System heats mainly by radiation.
Radiant energy is emitted by the floor giving an even distribution of heat. No cold spots, hot ceilings or cold feet.
The overall effectiveness of an UFH heating system can be seen below.
The heat is concentrated where it is most needed for comfort and efficiency.
Ideal
Heating
System
Floor
Heating
System
Radiator
Heating
System
Ceiling
18°C
Floor
24°C
RADIATOR SYSTEM AND HEAT GRADIENT
By contrast, radiators transfer heat from a relatively small area at a much higher temperature than the space being heated.
The radiator system heats mainly by convection. This results in the floor being the coolest place in the room, with the mass of warm air at ceiling level.
Ceiling
24°C
Floor
18°C
FEATURES & BENEFITS
The Speedfit Underfloor Heating System offers many benefits to the consumer. These include:
Installation
It is simple to install, requiring the minimum of installation effort and little maintenance.
Comfort
The system uses radiant heat, the most comfortable form of heating, to give a good even distribution of warmth over the whole room.
Space
The system in unobtrusive and space saving which means every square metre of floor and wall space can be fully utilised giving freedom of interior design.
Noise
Compared to radiator systems the system is virtually silent running.
Health
Dust is minimised reducing the problem of house dust mites. Reduced numbers of hot surfaces and sharp edges minimise risk of burns or injury.
Economic
Underfloor Heating Systems are designed to operate at lower temperatures than radiator systems, resulting in reduced energy consumption and lower heatloss from the building structure.
Control
The system is easy to control and the small temperature difference between the floor and air means the system is virtually self - regulating.
Environment
Underfloor heating is suitable for use with the most energy efficient and environmentally friendly heating systems including condensing boilers, solar power and heat pumps.
FLOOR FINISHES AND COVERING
The Speedfit Underfloor Heating System is suitable for most floor finishes, including ceramic tiles, carpets, vinyl and laminate.
The thermal resistance of floor covering will have a marked effect on the performance of the heating system.
Advice on the use of floor coverings and their effect on the performance of a system is laid out in the Speedfit
Underfloor Heating Manual.
22
23
SPEEDFIT SYSTEM COMPONENTS
Speedfit Underfloor Heating Products have been designed and are manufactured to European and UK Standards, including ISO 9001 and DIN4726.
MANIFOLDS
P
ART
N
O
.
D
ESCRIPTION
P
ACK
Q
TY
JGUFHMAN4
JGUFHMAN6
JGUFHMAN8
JGUFHMAN10
JGUFHMAN12
4 ZONE MANIFOLD
6 ZONE MANIFOLD
8 ZONE MANIFOLD
10 ZONE MANIFOLD
12 ZONE MANIFOLD
1
1
1
1
1
Supplied with Speedfit Pipe Inserts and Collet Clips.
Speedfit Manifolds are manufactured from high quality
DZR brass to the highest UK and European standards.
A unique feature is that connections to the heating pipes are Speedfit Push Fit, offering much reduced installation time. Flow and return rails are offset and the angles can be altered, all making for an easy installation.
The manifolds are complete with adjustable flow gauge, drain valve and air bleed valve. They are pre assembled on wall brackets and supplied with screws and plugs.
MANIFOLD EXTENSION KIT
P
ART
N
O
.
D
ESCRIPTION
P
ACK
Q
TY
JGUFHMANEXT MANIFOLD EXTENSION KIT 1
Enables a manifold to be extended by one or more zones.
MANIFOLD ELBOW CONNECTOR
P
ART
N
O
.
JGUFHMANELB
P
ACK
Q
TY
1 PAIR
Enables a Pump Pack and
Manifold to be installed at 90º to each other.
PUMP PACK
P
ART
N
O
.
D
ESCRIPTION
P
ACK
Q
TY
JGPUMPPACK PUMP PACK 1
Manufactured in DZR brass, the pack consists of a pump, mixing valve and overheat temperature thermostat.
Hot water is taken from the boiler, mixed to the required temperature and circulated via the manifold to the heating circuits, the temperature and volume of water is constantly altered to maintain the requirements of the system. Flow temperature can be altered by turning the hand wheel on the mixing valve unit.
The pack is light and compact so a wall bracket is not needed and flat face unions make for an easy connection to the manifold.
PEX BARRIER PIPE
P
ART
N
O
.
D
ESCRIPTION
S
IZE
P
ACK
Q
TY
15BPEX-50C BARRIER PIPE 15MM X 50M 1
15BPEX-100C BARRIER PIPE 15MM X 100M 1
15BPEX-120C BARRIER PIPE 15MM X 120M 1
15BPEX-150C BARRIER PIPE 15MM X 150M 1
POLYBUTYLENE BARRIER PIPE
P
ART
N
O
.
D
ESCRIPTION
S
IZE
P
ACK
Q
TY
15BPB-50C BARRIER PIPE 15MM X 50M 1
15BPB-100C BARRIER PIPE 15MM X 100M 1
15BPB-120C BARRIER PIPE 15MM X 120M 1
15BPB-150C BARRIER PIPE 15MM X 150M 1
Offered in PEX or Polybutylene, Speedfit Pipe has an inner barrier to prevent the ingress of atmosphere, it is manufactured and Kitemarked to British Standard
BS7291 : Parts 1,2 & 3: Class S.
It is lightweight and flexible making it especially suitable for underfloor heating installations.
For screed systems, the pipe is attached directly to insulation with staples, floor clips or mounting rails.
Spreader Plates are available for timber flooring using either traditional joists or TJI Joists.
PIPE FIXING SYSTEMS
Speedfit offer several ways of securing pipe to the insulation layer in a screeded floor.
P
ART
N
O
.
D
ESCRIPTION
S
IZE
P
ACK
Q
TY
JGUFHSTAPLE
JGUFHGUN
PIPE STAPLES
STAPLE GUN
60mm 300
1
Black Staples are barbed to ensure a secure fixing to the insulation. Easy fixing is carried out by using a
Staple Gun, securing pipe to the insulation with an easy repeatable action.
P
ART
N
O
.
D
ESCRIPTION
P
ACK
Q
TY
JGUFHRAIL
JGUFHPIN
2 METRE LONG
RAIL PINS FOR ABOVE
16
100
Mounting Rails offer a quick installation of 15mm pipe.
Supplied 2 metres long, the rails are pre scored every
100mm for easy cutting. The rail can be secured to the insulation using red Rail Pins.
P
ART
N
O
.
D
ESCRIPTION
P
ACK
Q
TY
JGUFHCLIP FLOOR CLIP
JGUFHTOOL FOR EASY FIXING OF FLOOR CLIPS
100
1
Floor Clips screw easily into insulation, they are best installed using a Fixing Tool.
EDGE INSULATION STRIP
P
ART
N
O
.
JGUFHEDGE
D
ESCRIPTION
25 METRE ROLL
P
ACK
Q
TY
1
Supplied in 25 metre rolls, the edge insulation strip is placed round the edge of each room to provide insulation of the heated floor.
FLOOR PANELS
P
ART
N
O
.
JGUFHTILE
D
ESCRIPTION
P
ACK
Q
TY
12 Floor Tile
1400mm x 800mm
Supplied in packs of 12, Speedfit Floor Tiles have an 11mm layer of insulation for support and additional thermal insulation.
SPREADER PLATES
P
ART
N
O
.
D
ESCRIPTION
P
ACK
Q
TY
JGUFHSP400
JGUFHSP250
JGUFHSP165
390mm x 1000mm
390mm x 250mm
165mm x 1000mm
1
1
1
Spreader Plates are available for timber flooring using either traditional joists or TJI Joists.
Spreader Plates 390 x 1,000mm and 390 x 250mm are laid across traditional joists and fixed in place using a hand stapler.
Spreader Plates 165 x 1000mm can be used with traditional and TJI joists. They are fixed to the underside of the floor using staples or screws.
Speedfit Pipe is fixed in the grooves of the plates.
When the plates and pipework have been installed, insulation is placed in the void below the plates to minimise downward heatloss.
ACTUATOR VALVE
P
ART
N
O
.
D
ESCRIPTION
P
ACK
Q
TY
JGUFHA(240 v) 240 v CIRCUIT ACTUATOR VALVE 1
Actuators are attached to the individual heating circuits on the manifold, providing individual control to a room or zone.
They open or close the flow of water and are controlled by a thermostat or programmer.
MASTER WIRING CENTRE
P
ART
N
O
.
JGUFH4ZM
D
ESCRIPTION
MASTER WIRING CENTRE 4 ZONE
P
ACK
Q
TY
1
Used to connect the wiring from thermostat, actuators, boiler and pump and manage the control of the underfloor heating system.
WIRING CENTRE SLAVE
P
ART
N
O
.
D
ESCRIPTION
P
ACK
Q
TY
JGUFH4ZS
JGUFH6ZS
WIRING CENTRE SLAVE 4 ZONE
WIRING CENTRE SLAVE 6 ZONE
1
1
Connects to a Master Wiring Centre to give an additional 4 or 6 zones.
WET AREA PROBE + COVER
P
ART
N
O
.
JGUFHTHKIT
D
ESCRIPTION
WET AREA PROBE + COVER
P
ACK
Q
TY
1
Used in conjunction with the Room
Thermostat with set back control or
Digital Room Thermostat, the kit is used in areas where the use of 240v would be a problem.
A 3 metre long cable connects a non electrical probe to a room thermostat.
DIGITAL ROOM THERMOSTAT
P
ART
N
O
.
D
ESCRIPTION
P
ACK
Q
TY
1 JGUFHTHDIG DIGITAL ROOM
THERMOSTAT
Works in conjunction with a Centralised or Remote System Timer
A mains operated room thermostat. The temperature is set manually to ‘Daytime’ temperature and reduced by
4 o C to ‘Setback’ temperature by a Centralised or Remote
System Timer. It has a manual override for permanent
‘Daytime’ or permanent ‘Setback’ temperature and can be used in conjunction with a Wet Area Probe.
PROGRAMMABLE ROOM THERMOSTAT
P
ART
N
O
.
D
ESCRIPTION
JGUFHPRS PROGRAMMABLE ROOM
THERMOSTAT
P
ACK
Q
TY
1
The Programmable Room Thermostat is a fully programmable electronic room thermostat which can be set to give each zone an individual time and temperature control.
CENTRALISED SYSTEM TIMER
P
ART
N
O
.
D
ESCRIPTION
P
ACK
Q
TY
JGUFHTIMER-C CENTRALISED SYSTEM TIMER
To be used with a Speedfit Set Back Thermostat.
1
If specified, one timer is needed for each manifold in the system. The timer provides centralised control of the set back functions for the whole manifold via a digital programmer. The timer acts as a timed switch to alternate between ‘daytime’ and ‘Set Back’ time.
REMOTE SYSTEM TIMER
P
ART
N
O
.
D
ESCRIPTION
P
ACK
Q
TY
JGUFHTIMER-R REMOTE SYSTEM TIMER 1
ROOM THERMOSTAT
P
ART
N
O
.
D
ESCRIPTION
P
ACK
Q
TY
JGUFHTH ROOM THERMOSTAT WITH
SET BACK TEMPERATURE REDUCTION MODE
1
Works in conjunction with a Centralised or Remote System Timer
A mains operated room thermostat. The temperature is set manually for ‘daytime’ temperature. A ‘set back’ mode, reducing the temperature by 4 o C, is controlled by a Centralised or Remote System Timer. The Thermostat has a manual override for permanent ‘Daytime’ or permanent ‘Set back’ temperature and can be used in conjuncton with a Wet Area
Probe.
A 4 channel programmer. Ideal for installations where the system timer needs to be located away from the manifold.
Can also be used, via a Master Wiring Centre, to control the set back for up to 4 Speedfit Room Thermostats. On a larger system the Remote System Timer can be used to replace a number of individual programmers, controlling say underfloor heating, radiators and hot water.
UNDERFLOOR HEATING SPARE PARTS
P
ART
N
O
.
D
ESCRIPTION
P
ACK
Q
TY
SPUFH1
SPUFH2
SPUFH3
SPUFH4
SPUFH5
SPUFH6
MIXING VALVE CARTRIDGE KIT
PUMP PACK FLOW TEMP GAUGE
OVER HEAT STAT
MANIFOLD FLOWMETER
MANIFOLD BALANCING VALVE
DUST CAP FOR BALANCING VALVE
1
1
1
1
1
1
24
25
SPEEDFIT SYSTEM COMPONENTS
SINGLE ROOM CONTROL UNIT
P
ART
N
O
.
D
ESCRIPTION
JGROOMPACK SINGLE ROOM CONTROL UNIT
P
ACK
Q
TY
1
The new Speedfit Underfloor Heating
Control Unit is the ideal way to provide heating to a conservatory or room extension, up to 30m 2 .
The unit is pre-assembled and pre-wired to allow for a fast and simple installation.
The control unit has integral ball valves to allow for isolation from the primary heating system, an adjustable blending valve and a 6 metre head circulation pump. An anti-vibration mounting bracket ensures silent operation.
Speedfit push in connections make for a fast connection to pipework.
Speedfit recommend connection to the main central heating flow and return distribution system, but it is also possible to connect to the nearest radiator supply pipe.
A full and detailed installation guide is provided with each unit.
The Speedfit Underfloor Heating Control Unit is suitable for use when:
• The boiler serving the existing heating system has the capacity to take the extra output from 2KW to 3KW
• The boiler is compatible with the additional pump
• The maximum area to be heated is 30 sq metres
The Control Unit is designed to be used with Speedfit
Barrier Pipe. The amount of pipe needed is determined not only by the size and shape of the room but by the resistance of the floor finish to heat transfer.
The table below shows examples of low resistance (tiles) and high resistance (carpet with underlay) finishes.
COIL SIZE TO AREA
Part
No.
Coil Size Staples Max Area Temp/Tiles Temp/Carpet Max Output
(m) Required (m 2 ) (ºC) (ºC) (KW)
15BPEX-150C 150
15BPEX-120C 120
15BPEX-100C 100
15BPEX-50C 50
240
200
170
100
20
17
14
7
44
44
44
44
58
58
58
58
1.8
1.5
1.2
0.6
SINGLE ROOM UNDERFLOOR HEATING PACK
P
ART
N
O
.
D
ESCRIPTION
JGUFHPACK20 UNDERFLOOR HEATING PACK
For conservatories or room extensions up to 20m 2 .
Pack contains: • Single Room Control Unit
• Programmable Room Thermostat
• 15mm x 150m coil Polybutylene Pipe with Pipe Clips and Pipe Inserts
P
ACK
Q
TY
1
SINGLE ROOM UNDERFLOOR HEATING PACK
P
ART
N
O
.
D
ESCRIPTION
P
ACK
Q
TY
JGUFHPACK30 UNDERFLOOR HEATING PACK
For conservatories or room extensions up to 30m
2
.
1
Pack contains: • Single Room Control Unit
• Programmable Room Thermostat
• 2 x 15mm x 100m coils of Polybutylene Pipe
• 300 x 15mm Pipe Clips
• 8 x 15mm Pipe Inserts
• 2 x 15mm Speedfit Equal Tees
• 2 x 15mm Speedfit Swivel Elbows
INSTALLATION IS QUICK AND EASY
SOLID FLOOR INSTALLATIONS
SCREEDS
The screed is an important and integral part of the UFH system, transferring energy from the pipes to the area to be heated. The response of this ‘thermal mass’ will depend on its depth and make up.
The usual depth of screed is 65 - 75mm thick but it is possible depths can be reduced to assist in improving performance.
PIPE LAYOUT IN SOLID FLOOR INSTALLATIONS
The shape of the room and the position of the outside walls and windows will determine the pattern of the pipe layout. The counterflow pattern is recommended although other options are shown below.
Single Serpentine Double Serpentine
Triple Serpentine Counterflow
The floor is cleared of dust and debris and insulation is laid across the area.
TIMBER FLOOR INSTALLATIONS
Spreader plates are available for timber flooring which uses either traditional joists or TJI joists.
Speedfit Pipe is laid in a pre-determined pattern and fixed in position with staples.
Fit the Speedfit Manifold to the wall and connect the
Pump Pack.
Connect the ends of the pipes to the Manifold.
Spreader plates 390mm x
1,000mm and 390mm x
250mm are designed for use with traditional joists at 400mm centres. They are laid across the joists and fixed in place using a hand stapler. The 15mm
Speedfit Pipe is pushed into the grooves in the plate and the floor decking laid on top.
Insulation can be placed between joists to the underside of the plates either before or after the plates have been laid.
The system is filled and pressure tested.
The screed should be laid whilst the pipe is pressurised.
The underfloor heating system should not be used to dry the concrete screed.
Spreader plates 165mm x
1000mm can be used with either traditional or
TJI joists and with the floor already in place.
They are fixed to the underside of the floor using staples or screws.
The Speedfit Pipe is fixed in to the groove.
When the plates and pipework have been installed, the insulation is placed in the floor void to minimise downward heat loss.
26
27
MAKING A GOOD CONNECTION
Cut pipe square using pipe cutters, remove burrs and sharp edges. Always use a pipe insert.
UNDERGROUND FITTINGS
APPLICATIONS
Speedfit underground fittings for metric size polyethylene cold water service pipe have been designed for connection of:
1. Blue MDPE pipes to BS 6572 - used for underground service pipes for potable water.
2. Black MDPE pipes to BS6730 - used for conveyance of potable water above ground or for industrial services above or below ground.
3. Pipe to ISO 161/1, ISO 3607 and DIN 16893.
Making the connection could not be easier. All you need is the pipe, the fitting and a pair of hands. The range is designed to provide a long service life and includes adaptors for screwed pipe, copper and imperial sized LDPE.
INSTALLATION BENEFITS
• Easy to use in confined spaces, no tools required.
• Fast installation with resulting cost savings.
• Lightweight and slimline.
• Ready for immediate installation, no dismantling.
• No adjustments required after fitting.
• Adaptors for screwed pipe, copper and imperial LDPE.
PERFORMANCE BENEFITS
• Maintenance free.
• Durable with high resistance to impact.
• Patented collet ensures high resistance to pull out.
• Lead free and non toxic.
• Will not support biological growth.
• A reliable and trouble free leakproof connection.
Push pipes into fitting
ʻOʼ ring
Collet
Pipe insert
The fitting is supplied ready for installation and requires no adjustment. Push the pipe into the fitting.
Collet Cover
Push the pipe up to the pipe stop. The collet has teeth that grip the pipe whilst the ‘O’ ring provides a permanent leak proof seal.
TO DISCONNECT
Ensure that the system is depressurised. Release and pull back collet cover.
Push in collet square against the face of fitting.
With the collet held in this position, the pipe can be withdrawn.
We recommend the replacement of the ‘O’ ring and collet before making a new connection.
CONNECTING TO IMPERIAL SIZE LDPE
Using the Inch Change Kit shown on page 28.
Remove collet cover, pull out metric size collet and
‘O’ ring. Keep with metric pipe support liner for future use.
Carefully push imperial size
‘O’ ring and collet into position, ensuring seal is clean before insertion.
Replace the snap-fit collet cover and, having inserted the imperial pipe support, connect the pipe as shown above.
PRODUCT RANGE
EQUAL STRAIGHT CONNECTOR
P
ART
N
O
.
JG401B
JG402B
Cold water only
S
IZE MM
20
25
REDUCING STRAIGHT CONNECTOR
P
ART
N
O
.
JG501B
Cold water only
S
IZE MM
25 x 20
EQUAL TEE
P ART N O .
JG201B
JG202B
Cold water only
S IZE MM
20
25
PE-COPPER COUPLER
Used to connect PE Pipe to copper or Speedfit Plumbing Pipe
P
ART
N
O
.
S
IZE MM
JG601B
JG603B
JG602B
20 x 15
25 x 15
25 x 22
Cold water only
Suitable for Tables X & Y Copper
MALE ADAPTOR
P
ART
N
O
.
JG101B
JG102B
Cold water only
S
IZE
20mm x 1/2” BSP
25mm x 3/4” BSP
FEMALE ADAPTOR
P
ART
N
O
.
JG4501B
JG4502B
Cold water only
S
IZE
20mm x 1/2” BSP
25mm x 3/4” BSP
PIPE INSERT
P
ART
N
O
.
UTS147 - DB
UTS197 - DB
S
IZE MM
20
25
INCH CHANGE KIT
To convert metric size fittings for use with imperial size LDPE to
BS1972 Class C or Class D
P ART N O .
JGK01E
JGK02E
Cold water only
S IZE MM
1/2”
3/4”
PLUGS
P ART N O .
JG801E
JG802E
Cold water only
S IZE MM
20
25
EQUAL ELBOW
SPARE PARTS
COLLETS
P
ART
N
O
.
20 UPC
25 UPC
S
IZE MM
20
25
P
ART
N
O
.
JG301B
JG302B
Cold water only
S
IZE MM
20
25
‘O’ RING
STEM ELBOW
P
ART
N
O
.
20 UOR
25 UOR
S
IZE MM
20
25
P
ART
N
O
.
JG222025B
JG222525B
P
IPE
OD
20mm
25mm
S
TEM
OD
25mm
25mm
28
29
TECHNICAL CHECKLIST -
PLUMBING AND HEATING FITTINGS
Fittings and pipe should be kept clean and undamaged before use.
• Chlorine. Speedfit is not suitable for use in systems where the water contains high levels of chlorine. e.g. swimming pools, fountains etc.
• Sizes.
10mm to 28mm diameter.
• Pipes.
Speedfit fittings can be used with:
Copper pipe to BS EN 1057
Speedfit Barrier Pipe to BS7291.
Speedfit fittings cannot be used on stainless steel pipe.
• Standards.
Speedfit products are designed and manufactured under a fully integrated system assessed by B.S.I. to BS EN ISO9001.
They are approved by the WRAS and BBA. Speedfit PEM, PSE and SFM
Fittings and Speedfit Barrier Pipe are Kitemarked to BS7291 Parts 1, 2 and 3, Class S. (Licence No. KM39767)
• Applications.
• Exposure to sunlight.
Speedfit products, when used indoors, are not affected by sunlight. When used outdoors protect from ultra violet light by lagging or painting.
• Pipe clips.
Pipe clips should not be fitted any closer than 60mm from the end of the fitting. Pipe should be adequately supported by pipe clips to
• Pipe inserts.
Must be used on all installations when using plastic pipe and should be fully inserted. Only use a Speedfit Insert with Speedfit Pipe.
• prevent undue stress (side load) on fittings.
Metal Joists.
When ʻcablingʼ plastic pipe through metal joists ensure rubber grommets are in place to prevent damage to pipe. Use of collet covers or collet clips on fittings recommended.
•
•
Mains fed and indirect cold water systems
Vented and unvented hot water systems
Vented and sealed central heating systems
Do not use for Gas, fuel oil or compressed air applications.
Working temperatures and pressures
• Connection to boilers.
A minimum 1000mm run of copper pipe must be installed between the boiler and the Speedfit system, as per BS5955: Part 8.
• Connection to copper pipe.
450mm is the minimum distance to make a solder connection on copper pipe inserted into a Speedfit Fitting. Ensure that any residual flux solder does not come into contact with the fitting.
•
Application
Cold Water
(indirect and direct mains)
Central Heating
Usual working temperature, ºC
20
82
Hot Water
(including unvented cylinders)
65
Burst Pressure (fittings).
Maximum working temperature, ºC
20
105, short term malfunction at 114
95
With copper or plastic pipe at 20°C: Speedfit fittings used with copper or Speedfit Barrier Pipe will withstand pressures well in excess of normal service conditions.
Maximum working pressure, bar
12
3
6
• Concrete and masonry.
Speedfit pipe and fittings can be laid in concrete and masonry providing they are installed in conduit pipe with access boxes for the fittings. This is to enable the pipe to expand and provide accessibility for both pipe and fittings. As stated in Water Regulation Scheme 2.7 and BS
8000 : Part 15, fittings and pipe should be removable for possible replacement.
Insulation is also recommended to protect against heat loss and the effects of frost.
• Electrical continuity.
If Speedfit is used in an existing metal system which may have been used for earthing, electrical continuity should be reinstated.
• Valves and taps.
Plastic 15mm and 22mm valves and taps available from
JG Speedfit Ltd are not suitable for central heating installations.
• High temperatures.
Can withstand 114°C intermittently for short periods.
The Speedfit system should not be used on an uncontrolled heat source.
• Insulation.
Should comply with BS6700 and BS5422, as for copper.
• Collet Covers.
Collet covers provide added security against pipe disconnection, e.g. the fittings coming into contact with rigid surfaces and behind dry-lining walls. They are offered in white as standard and in red or blue to provide colour coding of pipe.
• Minimum bend radii (PEX)
Pipe diameter
Min radius with clips
10mm 15mm 22mm 28mm
100mm 175mm 225mm 300mm
Min radius with cold forming bend 30mm 75mm 110mm -
• Collet Clips.
Grey collet clips are used with standard fittings to prevent accidental pipe disconnection. Red or blue clips provide colour coding of pipe. Red and blue clips should not be used to prevent accidental release of pipe.
• Clip spacing (in mm).
For surface mounted pipes
Pipe Diameter
10 - 15mm
22mm
Clip Spacing
Horizontal Run
300mm
500mm
Vertical Run
500mm
800mm
• System testing.
To ensure the pipework and fittings have been installed correctly, whether it be on a new or extended system, it is essential that the system is checked and hydraulically wet tested. Testing should be at 2 bar for 10 minutes and 10 bar for 10 minutes. This testing, combined with other relevant checks, should reveal installation problems and is regarded as good plumbing practice. However, system testing should not be regarded as a substitute for correct installation (see also “Making a Good Connection”).
• System flushing.
As is usual practice for any plumbing installation, flushing of the system prior to the use of Speedfit is recommended to remove any contaminants/ chemical residue from elsewhere in the system.
28mm 800mm 1,000mm
Where pipe is concealed, clipping may only be required where necessary.
• British Gas Service has accepted the John Guest Speedfit fittings as being suitable for open vented and sealed central heating systems and as eligible for acceptance onto its service contracts.
• Vermin.
Speedfit products will need special protection in vermin infested areas.
• Expansion (PEX pipe).
1% on length between 20°C and 82°C.
•
•
Flow rates.
Comparable with metal systems.
Cleaners, inhibitors and descalents.
For advice on the replenishment of additives such as corrosion inhibitors, the following manufacturers should be contacted: Fernox Manufacturing Limited on 01799 550811 or Sentinel,
BetzDearborn Limited on 0151 420 9595.
• Maximum Torque figures (BSP & BSPT).
Plastic threads are not generally as strong as brass threads. Customers and end users should be aware of this when choosing products for their applications. Overtightening of plastic threads will cause undue stress and eventual cracking and leakage. The maximum torque figures for BSP and BSPT threads used on Speedfit plumbing products in mating threads conforming to the relevant BS or International thread standards are shown below.
• Paint and Chemicals.
Use only water or oil based paint. Collet covers prevent paint ingress into fittings. DO NOT ALLOW CONTACT WITH oil based jointing compounds, cellulose based paints, paint thinners, paint strippers, solder flux, acid based descalents or aggressive cleaning products.
• Solder Flux.
No fluxes of any types should come into contact with
JG Speedfit Pipe and Fittings. If fluxes are to be used in an environment where Speedfit is installed, then (1) extreme care should be taken to ensure that no such contact takes place and (2) JG recommend installers only use fluxes tested and approved in writing in advance by JG. At the date of this publication, the only such approved flux is Fernox Flux.
•
Threads
Plastic
Brass
Side Loads.
Size
1/2”
3/4”
1/2”
3/4”
Fittings should not be subject to excessive side loads and they should not be used as support brackets. Tubing and fittings should be adequately supported to prevent excessive side loading.
Maximum Torque
3.0 Nm
4.0 Nm
4.0 Nm
5.0 Nm
TECHNICAL CHECKLIST -
UNDERFLOOR HEATING
• Applications.
Underfloor Heating Installations in solid or timber floors.
• Pipes.
15mm JG Speedfit Barrier Pipe to BS 7291, Parts 1, 2 and 3 Class S.
•
DO NOT USE
Speedfit UFH Products for Gas, fuel oil or compressed air applications.
• Floor Insulation.
Should be a suitable material and thickness to comply with current regulations.
• Minimum Bending Radii.
For Speedfit B-PEX Pipe is 175mm.
• Expansion (PEX - Pipe).
1% on length between 20˚C and 82˚C.
• Cleaners, Inhibitors and Descalents.
For advice on the replenishment of additives such as corrosion inhibitors, the following manufacturers should be contacted Fernox Manufacturing Limited on 01799 550811 or
Sentinel, BetzDearborn Limited on 0151420 9595.
• Paint and Chemicals.
Only use water or oil based paint. DO NOT ALLOW
CONTACT WITH cellulose based paints, paint thinners or strippers, solder flux or acid based descalents or aggressive household cleaning products.
• Exposure to sunlight.
Speedfit products, when used indoors, are not affected by sunlight. When used out doors protect from ultra violet light by lagging or painting.
• Pipe Inserts.
Must be used on all installations when using plastic pipe and should be fully inserted.
• Electrical Components.
Electrical products in the Speedfit Underfloor Heating
Systems are designed only to be used in U.K. Electrical Supply situations.
• Electrical Continuity.
If Speedfit is used in an existing metal system which may have been used for earthing, electrical continuity should be reinstated.
• Collet Clips. White and Grey collet clips are used with standard fittings to prevent accidental pipe disconnection. Red or blue clips provide colour coding of pipe. Red and blue clips should not be used to prevent accidental release of pipe.
• Pre-Screed System Testing. To ensure the pipework has been installed correctly and prior to the screed being laid, it is essential that the system is checked and hydraulically wet tested.
Testing should be carried out at 2 bar for 10 minutes and 10 bar for
10 minutes.
This testing, combined with other relevant checks, should reveal installation problems and is regarded as good plumbing practice.
• Pressurisation During Screed Laying & Curing. In accordance with
BS1264-4, the system should be left under pressure at a minimum of 6 bar for the duration of the laying and curing of the screed.
Under NO circumstances should the UFH System be used to quicken the screed drying process.
• System Flushing.
As is usual practice for any plumbing installation, flushing of the system prior to the use of JG Speedfit is recommended to remove any contaminants/chemical residue from elsewhere in the system.
• Vermin.
Speedfit products should not be used in vermin infested areas.
• Frost Protection.
During the installation process it is important that pipe containing water be protected from frost.
TECHNICAL CHECKLIST -
UNDERGROUND FITTINGS
• Applications.
Speedfit Underground Fittings are designed to connect
MDPE pipes (MRS-PE80) used above or below ground, to convey potable water from distribution mains to individual properties.
• Sizes.
20mm and 25mm with adaptors for:-
- Copper to BS2871 Part 1 / BS EN1057. Table X and Table Y.
- Screwed pipe.
- LDPE (to BS1972 Class C and Class D) in 1/2” and 3/4” inch sizes.
• Pipes.
Speedfit Underground Fittings can be used with:-
• Working Temperatures and Pressures.
Maximum working pressure
12 Bar @ 20˚C.
• Standards.
Speedfit Underground Fittings are approved by the
Water Regulations Advisory Scheme.
• Performance.
The fittings are manufactured from tough plastic material well able to meet the stringent requirements of the water industry. They have been approved by the WRAS and, as such, have passed the ʻpull out testʼ where a force shown below is applied to a connection between MDPE pipes and a fitting for 5 minutes without the connection failing.
Size
Test Force
Newtons lbs
20mm
1900
427
25mm
2500
562
• DO NOT USE FOR Gas, fuel oil or compressed air applications or hot water.
• Chemical Effects.
For below ground applications the fittings require no additional preparations - coating etc. When used above ground, avoid contact with aggressive chemical compounds. Protect from frost where necessary. In the United Kingdom, potable water does not contain high levels of chemicals (eg chlorine etc) that would adversely affect Speedfit Underground Fittings.
• Exposure to sunlight.
Permanent exposure to direct sunlight will necessitate lagging the fittings.
• Pipe Inserts.
Pipe inserts must be used and fully inserted on all connections to MDPE or LDPE pipe.
• System Testing.
Pressure test to 1.5 times working pressure for 10 minutes before connecting to the mains supply. It is recommended that all pipe and fitting installations are pressure tested after installation before handing over to the final user
• Maximum Torque Figures.
The maximum torque figures for BSP and BSPT threads used on Speedfit products are as follows:-
Size
1/2
3/4
Maximum Torque
3.0 Nm
4.0 Nm
It is recommended that all installations are checked prior to use to determine that a seal has been made.
The maximum torque figures quoted for use with Speedfit fittings are dependent on the mating thread conforming to the relevant British
International thread standards.
30
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project
Related manuals
advertisement