advertisement
Model 3161
Tension/Compression In-Line Load Cell
DESCRIPTION
The small-diameter, cost-efficient, fatigue-resistant load cells are designed to be used in applications that require an ability to mount in an existing system with restricted working area. They are commonly used in fluid power transfer systems. Their low cost and ease of mounting allow simultaneous testing of multielement systems.
They may be directly attached to the piston rod of a hydraulic cylinder. Side-mounted cable connectors allow cable assemblies to be supported without affecting movement of the cell during tension or compression loading.
FEATURES
• 2000 lb to 25000 lb range
• 0.15 % linearity
• 0.1 % hysteresis
• Fatigue resistant
• Adapts directly to hydraulic cylinder
• Small diameter allows mounting in restricted areas
• Low deflection
Model 3161
PERFORMANCE SPECIFICATIONS
Characteristic
Load range 1
Non-linearity
Hysteresis
Repeatability
Output @ rated capacity
Operation
Resolution
Standard calibration
Measure
2000, 5000, 10000, 25000 lb
±0.15 % of rated output
±0.1 % of rated output
±0.05 % of rated output
±2 mV/V (nominal)
Tension/compression
Infinite
Tension (+) and compression (-)
ENVIRONMENTAL SPECIFICATIONS
Characteristic
Temperature, operating
Measure
-54 °C to 93 °C [-65 °F to 200 °F]
Temperature, compensated 21 °C to 77 °C [70 °F to 170 °F]
Temperature effect, zero ±0.002 % of rated output/°F
Temperature effect, output ±0.002 % of reading/°F
ELECTRICAL SPECIFICATIONS
Characteristic
Strain gage type
Excitation (maximum)
Insulation resistance
Bridge resistance
(tolerance)
Number of bridges
Zero balance
Measure
Foil
20 Vdc or Vac RMS
> 5000 mOhm @ 50 Vdc
350 ohm
1 or 2
±1.0 %
MECHANICAL SPECIFICATIONS
Characteristic
Static overload capacity
Material
Natural frequency
Measure
150 % of nominal capacity
Carbon steel
See table
RANGE CODES
Range Code
DL
DR
DV
EM
Available ranges
2000 lb
5000 lb
10000 lb
25000 lb
TYPICAL SYSTEM DIAGRAM
In-Line Amplifiers
(Used with unamplified units only)
Amplifier Output
Universal In-Line Amplifiers
UV
UV-10
UBP
U3W
+/-5 VDC
+/-10 VDC
0 +/-5 VDC
4-20mA (3 wire)
U2W 4-20mA (2 wire)
DIN rail Mount In-Line Amplifiers
DV-05
DA-05
DV10
0 +/- 5 VDC (3 wire)
4-20mA (3 wire)
0 +/- 10 VDC (3 wire)
Honeywell
In-Line Amplifier
Output
Serial Number
Input
MODEL 3161
Customer Supplied
Chart Recorder
Alarm Panel
Data Acquisition
Computer
PLC
Power Supply
Display Units
SC500 SC1000 SC2000
SC2001 SC3004
GM NK HH
7541 7558 7561-PSD
OR
VALUE
UP
2003.1 lb.
L1 L2 L3 L4
CLEAR
DOWN
SETUP
CHAN
ENTER
TARE
EXIT
Mating Connectors & Cables
023-LW181-023-LF Mating Connector
7205-76-XX* Mating connector & 6 conductor cable
(unamplified unit with sense leads but not shunt cal)
7205-75-XX** Mating connector & 4 conductor cable
(unamplified unit without sense leads but not shunt cal)
7205-83-XX* Mating connector & 6 conductor cable
(for connection to instrument 7541)
7205-82-XX** Mating connector & 4 conductor cable
(for connection to instrument 7541)
* XX represents length in feet 100ft maximum
** XX represents length in feet 20ft maximum
2 Honeywell • Sensing and Control
Tension/Compression In-Line Load Cell
NATURAL FREQUENCY
Nominal load limit capacity F z lb N
2K
5K
10K
25K
10K
20K
50K
125K
Static extraneous load limits
150
150
150
150
Static overload capacity (% of nominal capacity)
Fatigue capacity (% of nominal capacity)
100
100
100
100
Shear F
X
F
Y
(lb)
or
850
850
850
2040
Bending M
X or M
Y
(lb-in)
Torque M
(lb-in)
Z
3800
3800
3800
6750
3500
3500
3500
9600
Deflection at nominal load limit
(in)
Ringing frequency
(Hz)
0.003
0.003
0.003
0.003
5000
6200
7100
11000
MOUNTING DIMENSIONS
Model
3161
A cm [in]
17,48 [6.88]
B cm [in]
2,54 [1.0]
G
RECEP.
PT02E-10-6P
C cm [in]
11,28 [4.44]
D cm [in]
4,29 [1.69]
E cm [in]
6,05 [2.38]
F cm [in]
1,27 [0.50]
G cm [in]
4,14 [1.63]
H cm [in]
0,64 [0.25]
OPTIONAL
DUAL BRIDGE
1.0-14 THD.
B DEEP
D
1.0-14 THD.
C
C
D
E
F
OPTIONAL
DUAL BRIDGE
9/32 DIA. M DEEP
4 HOLES EQUALLY SPACED
FOR SPANNER WRENCH
Honeywell • Sensing and Control 3
Model 3161
NOTES
1. This unit calibrated to Imperial (non-Metric) units.
Tension/Compression In-Line Load Cell
Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship.
Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to
Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages.
While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application.
Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing.
However, we assume no responsibility for its use.
For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847
Email inquiries to [email protected]
WARNING
PERSONAL INJURY
• DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury.
Failure to comply with these instructions could result in death or serious injury.
WARNING
MISUSE OF DOCUMENTATION
• The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information.
• Complete installation, operation and maintenance information is provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or serious injury.
Sensing and Control
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422 USA
+1-815-235-6847
www.honeywell.com/sensing
008660-1-EN IL50 GLO
May 2008
Copyright © 2008 Honeywell International Inc. All rights reserved.
advertisement