60 Hz 3 Phase AC to Bulk DC Converter

AR 60
60 Hz 3 Phase AC to Bulk DC Converter
(Inherent Harmonic Suppression)
• MIL-STD-1399 compliant
• Passive power factor correction
• Low parts count for high MTBF up to 500,000 hours (naval
sheltered environment)
• Rugged construction, MIL-STD-810 and MIL-S-901 compliant
• MIL-STD-167 compliant
• Rack mountable
TYPICAL FORCED-AIR COOLED MODEL
Abbott Technologies offers three standard types of harmonically corrected bulk converters:
• Unregulated with power factor correction and power levels from 1000 Watts to 25,000 Watts;
• Regulated with power levels from 1000 Watts to 5000 Watts;
• Battery Charger Configuration.
INPUT PRIMARY: 115V DELTA Suffix A
240V DELTA Suffix B
440V DELTA Suffix C
ISOLATION: Input to Output: 2500V
INPUT FREQUENCY: 60HZ, 3 Phase.
Power factor corrected.
VOLTAGE OUTPUT: 24, 28, 280, 300 COOLING METHODS:
Other voltages are available upon
Fan-Cooled - Suffix A (standard case);
Water-Cooled - Suffix H (consult factory for
request.
case dimensions)
Input to Case:
2500V
Output to Case: 500V
RELIABILITY:
MTBF 500,000 hours in naval sheltered
environment (for non-regulated models)
OPERATING TEMPERATURE:
Unregulated Units:
-40oC to + 85oC
Regulated Units or Chargers: -40oC to + 70oC (no derating)
MOUNTING PROVISIONS:
Soft-deck mounting is available with regular fans.
Hard-deck, ultra-rugged, mounting is available with heavy
duty fans.
MODEL NUMBER SYSTEM
AR60C - 50 - 28
A / RB (R- regulated model; B- battery charger)
DC OUTPUT VOLTAGE
24
28
280
300
COOLING METHOD
A - FORCED-AIR (INTEGRAL FANS)
H - WATER (INTEGRAL HEAT EXCHANGER)
TYPICAL WATER-COOLED MODEL
OUTPUT POWER (WATTS) *
10 - 1000W
15 - 1500W
25 - 2500W
35 - 3500W
50 - 5000W
75 - 7500W
100 - 10000W
MODEL FAMILY (60 Hz 3ø INPUT)
AR60A 115V DELTA INPUT
AR60B 240V DELTA INPUT
AR60C 440V DELTA INPUT
* For units with output power greater than 10,000 Watts, consult factory.
8203 Vineland Avenue
Sun Valley, CA 91352
Tel. 818-504-0644
Fax. 818-768-0395
POWER RATING
Harmonic current limits in MIL-STD-1399 are based upon a percentage of fundamental current at full load. Abbott
models are designed for compliant operation at full rated resistive load. Caution should be exercised when selecting
power rating of model to avoid overspecifying, as a converter operating too far below its rating may draw harmonic
currents in excess of MIL-STD-1399 limits, compared with delivered power.
Call us toll-free
1-800-367-8200
MAIN OFFICE:
8203 Vineland Avenue, Sun Valley, CA 91352 (818) 504-0644 FAX: (818)768-0395
Visit our website at www.abbott-tech.com and on-line quote form at sales@abbott-tech.com.
Last updated July 24, 2002
AR 60
60 Hz 3 Phase AC to Bulk DC Converter
(Inherent Harmonic Suppression)
REGULATION:
Unregulated models:
- Load Regulation: 10% Typical
- Line Regulation: N/A
Regulated models:
- Load Regulation: 2% Typical
- Line Regulation: 2% Typical
ENVIRONMENT:
Encapsulated to meet MIL-STD-810
for vibration,shock,acceleration,
sand, dust, humidity, saltspray,
fungus, sunshine, rain, explosion
and altitude.
BATTERY CHARGER OPTION:
- Units that are used for charging
batteries can be supplied with
smart battery charger feature,
factory configurable to meet your
specific battery charging
requirements.
- Temperature compensation
available.
- Units are available with up to 4
state charge profile (lead acid).
BUILT-IN TEST:
Regulated models only.
- Input phase loss.
- Input under/over voltage.
- Remote Enable/Disable.
- Output under/over voltage.
- Output overload alarm.
- Over temperature condition.
- Fan locked rotor alarm.
CONSTRUCTION:
To MIL-PRF-27, Grade 4,
Class S, steel case.
MECHANICAL DIMENSIONS
TYPE H - WATER-COOLED
TYPE A - FAN-COOLED
12.00
P
P
E
M
Output
Power (W) Size
2500
3500
5000
7500
10000
N
L
J
25
35
50
c
c
TYP
A
14.00
17.00
17.00
onsu
onsu
B
C
12.00 4.00
15.00 4.75
15.00 5.50
lt factor
lt factor
D
E
F
G
H
J
Rack Mount
Space (REF)
1.50 1.75 1.50 2.00 1.25 2.00 3U
1.50 2.25 1.50 2.00 1.25 2.00 3U
1.50 2.75 2.00 2.00 1.25 2.00 4U
y
y
Output
Power (W) Size A
1000
1500
2500
3500
5000
10
15
25
35
50
12.00
12.00
14.00
17.00
17.00
B
13.00
13.00
13.00
15.00
15.00
C
E
3.46
3.75
4.00
4.75
5.50
1.75
1.75
1.75
2.25
2.75
F
1.25
1.25
1.50
1.50
2.00
Rack Mount
G Space (REF)
1.50
1.50
2.00
2.00
2.00
K - UP TO 30A INPUT: .562: ABOVE 30A: .750
L - UP TO 150A: 5/16-18 STUD; ABOVE 150A: 3/18-16 STUD
8203 Vineland Avenue
Sun Valley, CA 91352
Tel. 818-504-0644
Fax. 818-768-0395
M - 37o FLAIR x 3/8 316 STAINLESS FITTINGS
N - UP TO 30A INPUT: 8-32 SCREW; ABOVE 30A: 1/4-20 STUD
P - SEE MOUNTING PROVISIONS PAGE FOR SLIDE AND BRACKET INFORMATION
R - SEE MOUNTING PROVISIONS PAGE FOR RACK PANEL INFORMATION
Specifications are subject to change without notice
Call us toll-free
1-800-367-8200
MAIN OFFICE:
8203 Vineland Avenue, Sun Valley, CA 91352 (818) 504-0644 FAX: (818)768-0395
Visit our website at www.abbott-tech.com and on-line quote form at sales@abbott-tech.com.
Last updated July 24, 2002
2U
3U
3U
3U
4U