ELECTRICAL
MODEL
VOLTS
WATTS
AMPS
PHASE
FIELD
WIRING
GAUGE
TEMP.
RATING
SS-8ULT
SS-8ULT
SS-8ULT
SS-8EUT
SS-8ULTD
SS-8ULTD
SS-8ULTD
SS-8EUTD
120
208
240
220-240
120
208
240
220-240
825
620
825
825
825
620
825
825
6.9
3.0
3.4
3.4
6.9
3.0
3.4
3.4
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
SINGLE
14 AWB Cu
14 AWB Cu
14 AWB Cu
14 AWB Cu
14 AWB Cu
14 AWB Cu
14 AWB Cu
14 AWB Cu
90°C
90°C
90°C
90°C
90°C
90°C
90°C
90°C
CUTOUT DETAILS
INSTALLATION INSTRUCTIONS
BUILT-IN ROUND FOOD WARMERS
MODELS SS-8ULT (D, EUT, EUTD)
INCHES
(MM)
PRODUCT DIMENSIONS
2 15/16
(75)
9
(229)
5
(127)
4 7/8
(124)
4
(102)
TOP CUTOUT
10 1/16
(256)
4
(102)
FRONT PANEL CUTOUT
CLEARANCES
8 3/4
(222)
6 1/4
(159)
MINIMUM CLEARANCE REQUIRED
UNIT TO THE NEAREST SURFACE
BACK
SIDE
BOTTOM
FRONT
1
1
8
4
(25)
(25)
(203)
(102)
CONDUIT
5 7/8
(149)
1/2 NPT
(ULTD MODELS)
2 3/4
(70)
INSTALLATION INSTRUCTIONS
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY
OUTLINED BELOW UPON INSTALLATION:
1. Required installation clearances:
Wooden and Metal Installation: DO NOT install closer than
4 inches to front wall, 1 inch to back and side walls,
and 8 inches to a surface below the unit.
2. Unit shall be accessible for servicing from the bottom.
3. If storage is to be used underneath the unit, it is
recommended that a baffle be placed 8 1/2 inches below
the unit to avoid contact with elevated temperatures.
5. Mount the control panel to control box using screws
supplied.
NOTE: INSTALLATION MUST MEET LOCAL PLUMBING AND
ELECTRICAL CODES.
TO FABRICATE:
1. Lay out "cutout" dimensions on countertop and front apron.
2. Lay out and fabricate control panel holes in counter
apron using the control box as a template.
3. Cut out holes.
MASTER
CONTROL
PANEL
TO INSTALL:
IMPORTANT - DO NOT disconnect lead wires from the
Control Panel when installing.
1. Press the self sticking 'gray' gasket material along the
perimeter of the appliance mounting flange, about 1/4 inch
from the outside edge. Remove the paper backing as the
gasket is applied.
RECOMMENDATION: Before final seating of modular section
to countertop, apply a bead of silicone adhesive/sealant
to the underside of warmer flange.
2. Locate warmer and control box over countertop cutout.
Pass control box through countertop cutout and front
panel cutout.
3. Seat warmer onto countertop and the mount control box
into front panel cutout.
4. From underneath, insert screwdriver into slots on
wellslok flange and twist outward (clockwise) to tighten
unit down to countertop (see detail at right).
IMPORTANT:
MOUNT APPLIANCE SO THAT THE CONTROL PANEL
IS LOCATED TO THE FRONT OF THE FIXTURE.
WELLS/BLOOMFIELD * VERDI, NV
WARMER FLANGE
GASKET
WELLSLOK
SCREWDRIVER
COUNTERTOP
46221-2 REV (A)