Kobe Range Hoods RA-092 SERIES Installation & Operating Instructions


Add to my manuals
22 Pages

advertisement

Kobe Range Hoods RA-092 SERIES Installation & Operating Instructions | Manualzz

KOBE Brand Range Hood

Model No. RA9236S

RA-092 SERIES – 12” HEIGHT

INSTALLATION INSTRUCTIONS

AND OPERATION MANUAL

- READ AND SAVE THESE INSTRUCTIONS -

CONTENTS

Important Safety Instructions……………………………………………………………….

Components of Packages…………………………………………………………………..

Installation……………………………………………………………………………………

Operating Instructions…………………………………...………………………………….

Maintenance………………………………………………………………………………….

Specifications…………………………………………………….……..……………………

Measurements & Diagrams…………………………………………………………...……

Parts List…………………………………………………………………..………………….

Circuit Diagram………………………………………………………………...…………….

Disclaimer…………………………………………………………………………………….

Warranty…………………………………………………………………...…………………

Product Registration………………………………………………………...………………

10

12

13

14

1

3

4

9

16

17

18

20

- READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING -

A LL W IR IN G M U S T B E D O N E B Y A P R O F E S S IO N A L A N D IN

A C C O R D A N C E W ITH N AT IO N A L A N D LO C A L E LE C T R IC A L C O D E S .

IMPORTANT SAFETY INSTRUCTIONS

- PLEASE READ THIS SECTION CAREFULLY BEFORE INSTALLATION -

WARNING – TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY,

OBSERVE THE FOLLOWING:

1) Installation and electrical wiring must be done by qualified professionals and in accordance with all applicable codes and standards, including fire-rated construction.

2) When cutting or drilling into wall or ceiling, be careful not to damage electrical wiring or other hidden utilities.

3) Ducted fans must be vented to the outside. a) Before servicing or cleaning unit, open the light panel and SWITCH POWER OFF AT

SERVICE PANEL. b) Clean fan, optional filter and grease laden surfaces frequently. To reduce the risk of fire and to disperse air properly, make sure to vent air outside. DO NOT vent exhaust air into wall spaces, attics, crawl spaces or garages.

NOTE - This warranty is invalid without an authorized agent’s receipt or if unit is damaged due to misuse, poor installation, improper use, mistreatment, negligence or any other circumstances beyond the control of KOBE

RANGE HOODS authorized agents. Any repair carried out without the supervision of KOBE RANGE HOODS authorized agents will automatically void the warranty.

- KOBE RANGE HOODS will not be held responsible for any damages to personal property or real estate or any bodily injuries whether caused directly or indirectly by the range hood.

WARNING – TO REDUCE THE RISK OF PERSONAL INJURY IN THE EVENT OF A RANGE

TOP GREASE FIRE:

Keep fan, filter, if any, and grease-laden surfaces clean.

Always turn hood ON when cooking at high heat.

Use high settings on cooking range ONLY when necessary. Heat the oil slowly on low to medium setting.

Do not leave cooking range unattended when cooking.

Always use cookware and utensils appropriate for the type and amount of food prepared.

Use this unit only in the manner intended by the manufacturer.

Before servicing, switch power off at service panel and lock service panel (if possible) to prevent power from switching on accidentally.

Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan, safety screens, and oil containers.

1

What to Do In The Event Of a Range Top Grease Fire

- SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray, and then turn off the burner. KEEP FLAMMABLE OR COMBUSTIBLE MATERIAL AWAY FROM FLAMES. If the flames do not go out immediately, EVACUATE THE AREA AND CALL THE FIRE

DEPARTMENT or 911.

- NEVER PICK UP A BURNING PAN – You may get burned.

- DO NOT USE WATER, including wet dishcloths or towels – a violent steam blast will result.

- Use an extinguisher ONLY if: a) You have a Class A, B, C extinguisher and know how to operate it. b) The fire is small and contained in the area where it started. c) The fire department has been called. d) You can fight the fire with your back to an exit.

What to Do If You Smell Gas

- Extinguish any open flame.

- Do not try to turn on the lights or any type of appliance.

- Open all doors and windows to disperse the gas. If you still smell gas, call the Gas

Company and Fire Department right away.

CAUTION

1) For general ventilation use only. Do not use to exhaust hazardous or explosive materials and vapors.

2) To reduce the risk of fire, use only metal ductwork.

3) Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for

Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and code authorities.

4) Activating any switch may cause ignition or an explosion.

ELECTRICAL SHOCK HAZARD – Can result in serious injury or death.

Disconnect appliance from electric power before servicing.

If equipped, the fluorescent light bulb contains small amounts of mercury, which must be recycled or disposed of according to Local, State, and

Federal Codes.

2

COMPONENTS OF PACKAGE

(M u s t k e e p a ll m a te ria l fo r re tu rn s o r re fu n d s )

Range Hood Box

{A} KOBE Range Hood with Two-Piece Duct Cover

{B} Warranty Registration Card

{C} Instructions Manual

{D} Duct Cover-Mounting Bracket

{E} Hood-Mounting Bracket

{F} Oil Containers (Round)

{G} Oil Containers (Oval)

{H} Screws Package

{A} {D} {E}

***Attached to Hood

{B} {C} {F} {G}

{H}

3

INSTALLATION

PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING

Calculation before Installation

To calculate the length of the installation, please refer to Table 1. (All calculation is measure in inches.)

TABLE 1

A = Height of Floor to Ceiling

B = Height of Floor to Counter Top

(Standard: 36”)

C = Preferred Height of Counter Top to Hood Bottom (Recommended

27” to 30”)

D = Height of Hood

E = Height of Duct Cover [F – D]

F = Height of the Hood Installation

[A – (B+C)]

SAFETY W A RNIN G

HOOD MAY HAVE VERY SHARP EDGES; PLEASE WEAR PROTECTIVE GLOVES IF IT

IS NECESSARY TO REMOVE ANY PARTS FOR INSTALLING, CLEANING OR

SERVICING.

Preparation before Installation

NOTE: TO AVOID DAMAGE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE

VENT OPENING.

- Decide the location of the venting pipe from the hood to the outside. Refer to Figure 1.

- A straight, short venting run will allow the hood to perform more efficiently.

- Try to avoid as many transitions, elbows, and long run as possible. This may reduce the performance of the hood.

- Use duct tape to seal the joints between pipe sections.

- If necessary, prepare back wall frame with cross framing lumber for secure installation.

Using references on Table 1 and measurements on page 13, decide the level of the lumber. Refer to Figure 2.

4

- Temporarily wire the hood to test for proper operation before installing.

- Peel protective film off the duct cover and the hood (if any).

- Loosen hood-mounting brackets at the back of the hood, adjust brackets and tighten screws as shown in Figure 3.

- If necessary to remove the rubber stand on the back of the hood, unscrew and discard.

Refer to Figure 4.

Figure 1 Figure 2

Figure 3 Figure 4

Attached

Rubber Stand

Hood Installation

CAUTION: If required to move the cooking range to install the hood, turn OFF the power on an electric range at the main electrical box. SHUT OFF THE GAS BEFORE MOVING A GAS

RANGE.

1. Using references on Table 1 and measurements on page 13, mark the leveling point for hood-mounting bracket on the wall.

2. Secure two mounting screws (not provided) on the wall leaving 1/8” away from the wall.

Refer to Figure 5.

3. Align hood-mounting bracket to the mounting screws on the wall and hook hood into place.

4. Secure and tighten the mounting screws. CAUTION: MAKE SURE THE HOOD IS

SECURE BEFORE RELEASING.

5

Figure 5

Mounting

Screws

Ductwork Installation

5. Use 6” round aluminum or steel pipe to connect the plastic exhaust on the hood to the ductwork above. Use duct tape to make all joints secure and air tight. Refer to Figure 6.

Figure 6

Wiring to Power Supply

SAFETY W A RNIN G

RISK OF ELECTRICAL SHOCK. THIS RANGE HOOD MUST BE PROPERLY GROUNDED.

MAKE SURE THIS IS DONE BY SPECIALIZED ELECTRICIAN IN ACCORDANCE WITH ALL

APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES. BEFORE CONNECTING

WIRES, SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO

PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY.

6. Connect three wires (black, white and green) to house wires and cap with wire connectors.

7. Connect according to color: black to black, white to white, and green to green.

8. Test the operation of the hood before moving on to next step. Make sure power is supplied to the hood.

Duct Cover Installation

NOTE: BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER, DAMAGE TO THE

HOOD MAY OCCURS.

6

9. Using reference E from Table 1 and measurements on page 13, mark the leveling point for duct cover-mounting bracket.

10. Secure the duct cover-mounting bracket to the wall with two screws (not provided). Refer to Figure 7. Make sure all screws are tightened. NOTE: Inner duct cover will cover the duct cover-mounting bracket.

11. Slide up inner duct cover up 2 inches before sliding entire duct cover onto the hood.

Refer to Figure 8.

Figure 7 Figure 8

12. Adjust the height of the inner duct cover to the duct cover-mounting bracket. Secure inner duct cover with two (4x8 mm) screws (provided) as shown in Figure 9.

Attach Together

Figure 9

13. Fasten outer duct cover to plastic plate on the hood with four (4x8 mm) screws (provided).

Install Accessories

14. Place the oil container (round) into keyhole under each safety screen. Turn clock-wise until firmly in place. Refer to Figure 10.

15. Slide oil container (oval) into plastic slot behind each safety screen as shown in Figure

11.

7

Figure 10 Figure 11

Final Assembly

16. Turn power ON in control panel. Check all lights and fan operation.

17. Make sure to leave this manual for the homeowner.

8

OPERATING INSTRUCTIONS

This KOBE hood is equipped with three-switch control, two powerful centrifugal turbine impellers with safety screens, two bright 12-volt 20-watt halogen lights, and four oil containers.

The three control switches are Light Control, Speed Control, and the Power Control (On/Off).

Refer to Figure 12.

Figure 12

Light Control Power Control

Speed Control

Low High

Turn On:

- Press Power Control switch to turn on the power.

- Press the Speed Control (Low, Off, High) to select the desired speed. Once the

Power Control is turned on, the prior switch selections will turned on.

- Press Light Control switch to turn halogen lights on.

Turn Off:

- Press the Power Control switch to turn off all power. Note: The Power Control switch is the main power controller.

9

MAINTENANCE

CAUTION: NEVER PUT YOUR HAND INTO THE AREA HOUSING THE FAN WHILE THE

FAN IS OPERATING.

For the optimal level of operation, clean the range hood surface, safety screens, and oil containers regularly.

To Clean Hood Surface

CAUTION: NEVER USE ABRASIVE CLEANERS, PADS, OR CLOTHS.

*** Regular care will help preserve its fine appearance.

1) Use only mild soap or detergent solutions. Dry surfaces using soft cloth.

2) If hood looks splotchy (stainless steel hood), use an orange base cleaner to clean the surface of the hood. Avoid cleaner to get on the control switches. Only spread a light coating over the surface of the hood and leave on for a few minutes (do not leave on too long or this may cause damage to hood finish). Use soft towel to wipe off the cleaning solution, gently rubs any stubborn spots. Use a slightly damp towel to get rid of any cleaning solution. Use dry soft towel to dry the hood.

3) To bring the glow back into a stainless steel finish, use a stainless steel cleaner.

4) DO NOT allow deposits to remain for long periods of time.

5) DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface causing rust.

6) DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with stainless steel for extended periods. Many of these compounds contain chemicals, which may be harmful. Rinse with water after exposure and wipe dry with a clean cloth.

To Clean Oil Containers, Safety Screens and Impellers

CAUTION: DRAIN OIL CONTAINER BEFORE OIL CAN OVERFLOW.

1) Normal Cleaning

- Spray a mild degreaser into the fan and turn on high speed. Liquid residue will accumulate in the oil containers.

2) Cleaning Oil Containers

- Remove the oil container (round) by turning counter-clockwise.

- Remove the oil container (oval) by sliding forward.

- Wash with warm soapy water. Dry completely before returning into place.

- Top rack dishwasher safe.

3) Cleaning Safety Screens

- Remove the safety screen screw and slide the safety screen out.

- Wash with warm soapy water. Dry completely before returning into place.

- Top rack dishwasher safe.

10

To Replace Light Bulb

CAUTION: HALOGEN LIGHT UNIT MAY BE HOT! WAIT UNTIL UNIT IS COOL.

1) Make sure all control switches are off, and range hood is unplugged.

2) Use a flat head screwdriver to pop out the protective covering as shown in Figure 15.

3) Gently pull out the defective light bulb and discard. Light bulbs should be 12V 20W maximum. Refer to Figure 16. Push bulb securely into light socket.

4) Replace protective cover.

5) Plug in range hood.

Figure 15 Figure 16

11

SPECIFICATIONS

MODEL / SIZE

COLOR

VOLTAGE

NUMBER OF MOTORS

DESIGN

RA9236S / 36”

# 430 Commercial Grade Stainless Steel

120V 60Hz

2

18-Gauge Seamless

FAN TYPE

EXHAUST

CONTROLS

Twin Turbine Impeller

6” Round

Two Speed (Low & High)

HALOGEN LIGHTS 12V 20W x 2

HOOD DIMENSION (W x D x H) (RA9236S) 35-1/4” x 20-1/2” x 12-1/4”

DUCT COVER DIMENSION

(W x D x H)

(RA9236DC) 10-5/8” x 7-7/8” x (14-1/8”~27-1/8”)

OPTIONAL ACCESSORIES

(W x D x H)

WEIGHT (lbs)

SPEED

Air Capacity (cfm)*

Sone

*In House Test Static Pressure “0”.

**Specifications subject to change without notice.

1) One-Piece Extension Duct Cover

(RA0925DC) 10-5/8” x 7-7/8” x (14-1/8”~39-1/4”)

(RA0946DC) 10-5/8” x 7-7/8” x (14-1/8”~60-1/2”)

2) 36” Stainless Steel Back Panel

(SSP36) 36” x 1/10” x 32”

(RA9236S)

Net

46.2

Gross

52.8

Low

400

1.9

High

600

4.8

12

MEASUREMENT & DIAGRAM

***All inch measurements are converted from millimeters. Inch measurements are estimated.

***All measurements in ( ) are millimeters.

***Hood-Mounting Bracket ***Duct Cover-Mounting Bracket

13

PARTS LIST

MODEL NO.: RA9236S

29

30

31

32

33

34

21

22

23

24

25

26

27

28

35

36

37

14

15

16

17

18

19

20

11

12

A

B

13

5

6

7

8

9

10

NO. DESCRIPTION

1

2

3

4

6” Round Plastic Exhaust

Capacitor

Transformer (Motor)

Screw (4 x 6 mm)

Screw (4 x 6 mm)

Power Cord

Round Head Screw (TS 4 x 18 mm)

Plastic Plate

Hood Casing

Transformer Support

Halogen Light (12V 20W Max.)

Air Chamber

Air Chamber (Top)

Air Chamber (Side)

Motor (Left)

Motor (Right)

Motor Position Screw (TS 1/4” x 7/16”)

Turbine Impeller (Left)

Turbine Impeller (Right)

Oil Tunnel Seal

Oil Tunnel

Bottom Casing

Oil Container (Oval)

Safety Screen

Oil Container (Round)

Safety Screen Screw

Screw (3/16” x 5/8”)

Impeller Plastic Cover

On/Off Switch

Speed Switch

Light Switch

Rubber Stand

Screw (4 x 8 mm)

Screw (3/16” x 3/8”)

Hood-Mounting Bracket

Duct Cover

Round Head Screw (TS 4 x 8 mm)

Round Head Screw (TS 4 x 8 mm)

Duct Cover-Mounting Bracket

14

MODEL /SIZE

RA9236DC

PART NO.

C1-0506-0101

C1-0401-0120-01A

C1-0402-0120-40

C1-0708-0001

C1-0708-0001

C1-0406-0120

C1-0708-0004

C1-0507-0101

10-00920-A

C1-0201-0092

C1-0403-0101

C1-0101-0092

C1-0102-0092

C1-0301-0120-11A

C1-0301-0120-12A

C1-0703-0001

C1-0251-0092-01

C1-0251-0092-02

C1-0502-0301

C1-0502-0203

B101-0092-09

C1-0504-0101

C1-0602-0101

C1-0503-0101

C1-0705-0001

C1-0704-0004

C1-0251-0001

C1-0405-0110

C1-0405-0112

C1-0405-0113

C1-0511-0101

C1-0706-0001

C1-0707-0001

C1-0221-0092

12-01000-304

C1-0708-0006

C1-0708-0006

C1-0203-0002

MODEL NO.: RA9236S

15

CIRCUIT DIAGRAM

MODEL NO.: RA9236S

KEY CODE

B

BK

BR

W

GR

Y

G

L

R

=

=

=

=

=

=

=

=

=

Blue

Black

Brown

White

Green

Yellow

Grey

Left

Right

16

DISCLAIMER

1. CAREFULLY INSPECT ALL ITEMS FOR DAMAGES BEFORE ACCEPTING

DELIVERY. NOTE ANY DAMAGES ON THE FREIGHT BILL OR EXPRESS

RECEIPT. REQUEST NAME AND SIGNATURE OF THE CARRIER’S AGENT AND

KEEP COPY TO SUPPORT YOUR CLAIM.

Upon acceptance of items, owner assumes responsibility for its safe arrival. Damages should be reported to carrier and a claim filed. Failure to do this could result in the carrier refusing to honor your claim. The carrier will furnish you with necessary forms for filing a claim.

DAMAGES CAUSED DURING TRANSIT ARE NOT COVERED UNDER OUR

WARRANTY.

2. PLEASE INSPECT CONTENTS OF PACKAGE (S) CAREFULLY UPON RECEIVING!

We must be notified in writing of any damages and/or missing parts within the allocated days upon receipt of package(s). Contact your local KOBE dealer or distributor or call

KOBE for the time limit.

CLAIMS WILL NOT BE ACCEPTED AFTER THE ALLOCATED DAYS.

NOTE: ITEMS WERE THOROUGHLY TESTED AND CAREFULLY PACKED IN OUR

FACTORY.

3. Products must be returned in good working condition with ALL original parts and documentation packed in ALL original cartons, fillers and shipping cartons. A restocking fee of 25% will be charged for all approved return(s).

EXCHANGES OR RETURNS MAY NOT BE ACCEPTED IF ANY PACKAGING IS

MISSING.

4. MAKE SURE TO INSPECT THE HOOD FOR DAMAGES AND DEFECTS BEFORE

INSTALLATION. Appearance flaws of the hood found after installation and not affecting hood performance is not covered under our warranty for returns or exchanges.

Service visits not covered under warranty will carry a service charge.

A) Before Installation: Return for exchange or refund (please see above for acceptable returns).

B) After Installation: NO exchange or refund.

17

WARRANTY

WARRANTY CERTIFICATE

KOBE Range Hoods, Inc. warrants all products manufactured or supplied by it to be free from defects in workmanship and materials. Its obligations pursuant to this warranty are limited to a period of two years from the date of purchase and to the repair or replacement at its option and subject to the terms and conditions stated below, of any component part, which its examination shall disclose to be so defective.

TWO-YEAR WARRANTY SERVICE PERIOD

Any covered failure occurring within two years of original purchase arising from defective workmanship or material in manufacture will be repaired (or at our option the unit will be replaced) free of charge by an authorized KOBE Range Hoods Agent or KOBE Range Hoods as applicable. Keep proof of purchase (or original invoice) handy for inspection.

If the range hood is sold by the original purchaser during the warranty period the new owner is protected until expiration of the original purchaser’s warranty.

CONDITIONS

The following conditions apply only in relation to the warranty expressly given in this certificate.

1) This warranty applies only: a) within U.S.A. and Canada. b) to range hoods used for PRIVATE SINGLE FAMILY USE (if used for COMMERCIAL or

MULTIPLE FAMILY USE or other purposes, warranty will be voided).

2) Repair of any fault to be provided under this warranty shall not be provided: a) if the identification number attached to the range hood has been altered, rendered illegible or removed; b) if notice of the defect has not been given within the period applicable; c) for failure of light bulbs; d) for physical damage; e) for surfaces damaged by use of improper chemical cleaning agents; f) if the appliance has been: i) subject to misuse, abuse, negligence, accident, incorrect installation or failure to follow the operating instructions; ii) connected to improper, inadequate or faulty electricity service or exhaust ducts or flues or operated using incorrect or contaminated lubricants; iii) installed, maintained or operated otherwise than in accordance with the instructions furnished by KOBE Range Hoods including the improper use of detergents, bleaches, or cleaners. g) for damage to range hood during transit, delivery, installation or removal; h) for damage by or resulting from attempted repairs conducted by anyone other than our

Authorized Service Agent.

18

3) The purchaser shall be responsible for any expenses involved in making the range hood readily accessible for servicing and where the range hood is installed outside the main sales territory of the retailer or service territory of the nearest approved KOBE Range

Hoods Agent as applicable, for any traveling expenses and any costs of transporting the range hood or parts thereof to and from the dealer or Service Agent

4) The purchaser must produce proof of purchase together with this warranty certificate when making the claim.

5) Damages caused during shipment are not covered under our warranty.

CONSEQUENTIAL DAMAGE

The warrantor is not responsible for any consequential damage. SOME STATES DO NOT

ALLOW THE EXCLUSION OF CONSEQUENTIAL DAMAGE SO THE ABOVE EXCLUSION

MAY NOT APPLY TO YOU.

IMPLIED WARRANTIES/STATE LAW

Any implied warranties, including the implied warranty of merchantability and fitness for purpose, imposed on the sale by the laws of the state of sale are limited to two year from the date of original purchase. Some states do not allow limitations on the duration of implied warranties. This warranty gives you specific legal rights, and may also have rights, which vary from state to state.

SERVICE

For service contact:

KOBE Range Hoods

4934 Walnut Grove Avenue

Suite 202

San Gabriel, CA 91776

U.S.A

Tel: (626) 309-1356 Fax: (626) 309-1366

Email: [email protected] www.KobeRangeHoods.com

19

PRODUCT REGISTRATION

Register Your Product!

Any covered failure occurring within two years of original purchase arising from defective workmanship or material in manufacture will be repaired or at our option the unit will be replaced free of charge by an authorized KOBE Range Hoods Agent or KOBE Range

Hoods as applicable. Keep proof of purchase (original invoice) handy for inspection.

If the range hood is sold by the original purchaser during the warranty period the new owner is protected until expiration of the original purchaser’s warranty. See warranty section for complete warranty coverage information.

This appliance has been manufactured, tested, and inspected to the standards required by

KOBE Range Hoods.

PLEASE MAIL IN YOUR WARRANTY REGISTRATION CARD AND A COPY OF PROOF

OF PURCHASE:

KOBE Range Hoods, Inc.

4934 Walnut Grove Avenue

Suite 202

San Gabriel, CA 91776

RECORD THE FOLLOWING INFORMATION FOR YOUR RECORD:

Model No. ________________________

Serial No. ________________________

Purchased Date _____/_____/_____

Purchased From:

______________________________

______________________________

______________________________

IMPORTANT: PLEASE KEEP A COPY OF YOUR SALE RECEIPT OR INVOICE HANDY

WHEN REQUESTING FOR SERVICE.

20

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement