White-Rodgers humidifier specification - Bel

HDT and
HFT SERIES
HUMIDIFIERS FOR
WARM AIR HEATING SYSTEMS
INDOOR AIR QUALITY/
ZONING SYSTEMS
HDT2600 DRUM TYPE BYPASS HUMIDIFIER
A Good Choice for Lower Efficiency Warm Air Heating Systems
FEATURES
HDT2600
INSTALLATION PACKAGE
Includes universal humidistat, self-piercing
saddle valve, bypass tubing, 24 volt transformer, summer shut-off damper, mounting
template, mounting hardware and homeowner’s manual/installation instructions.
• Unique snap-lock fittings and reversible components allow quick installation
and maintenance.
• Uses minimal water and electricity.
• Durable thermoplastic cabinet resists rust, corrosion and warpage.
• Interior components designed for easy cleaning or replacement.
• Output capacity of 17.0 gallons per day (GPD) at 120°F.
SPECIFICATIONS
Overall Dimensions, HDT2600 . . . . . . . . . . . . 105/16”H x 1111/16”D x 123/8”W
Plenum Opening . . . . . . . . . . . . . . . . . . . . . . . 65/8”H x 81/2”W
Bypass Opening . . . . . . . . . . . . . . . . . . . . . . . 6”diameter
Drum Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 VAC, 3 watt, 1 RPM, bidirectional
PARTS AND ACCESSORIES
See page 233 for parts and accessories
HFT2100/2700 HIGH-CAPACITY BYPASS
FLOW-THRU HUMIDIFIER WITH SIDE ENTRY
An Excellent Choice for Warm Air Heating Systems
FEATURES
• Designed to fit today’s narrower plenums – as narrow as 10” (HFT2100) or 14” (HFT2700).
• Reversible side panels with unique snap-lock fittings permit easy-change left-side
or right-side bypass installation.
• New, improved wicking and water distribution system allows for non-level plenums.
• Durable thermoplastic cabinet resists rust, corrosion and warpage.
• Low profile makes unit ideal where space is limited.
HFT2100/2700
INSTALLATION PACKAGE
Includes universal humidistat, self-piercing
saddle valve, 24 volt transformer, mounting
template, mounting hardware and homeowner’s manual/installation instructions.
SPECIFICATIONS
Overall Dimensions, HFT2100 . . . . . . . . . . . . 131/2”H x 95/8”D x 121/2”W
Overall Dimensions, HFT2700 . . . . . . . . . . . . 185/8”H x 95/8”D x 133/4”W
Plenum Opening, HFT2100 . . . . . . . . . . . . . . . 10”H x 9”W
Plenum Opening, HFT2700 . . . . . . . . . . . . . . . 165/8”H x 105/8”W
Bypass Opening . . . . . . . . . . . . . . . . . . . . . . . 6”diameter
PARTS AND ACCESSORIES See pages 234-235 for parts and accessories
HFT2900FP HIGH-CAPACITY
FAN-POWERED FLOW-THRU HUMIDIFIER
A Premium Choice for Warm Air Heating Systems
FEATURES
HFT2900FP
INSTALLATION PACKAGE
Includes universal humidistat, self-piercing
saddle valve, 24 volt transformer, mounting
template, mounting hardware and homeowner’s manual/installation instructions.
• Designed to fit today’s narrower plenums – as narrow as 14”.
• Ideal for installations where the return air plenum is not easily accessible.
• New, improved wicking and water distribution system allows for non-level plenums.
• Durable thermoplastic cabinet resists rust, corrosion and warpage.
• Low profile makes unit ideal where space is limited.
SPECIFICATIONS
Overall Dimensions, HFT2900FP . . . . . . . . . . 185/8”H x 95/8”D x 133/4”W
Plenum Opening . . . . . . . . . . . . . . . . . . . . . . . 165/8”H x 131/8”W
PARTS AND ACCESSORIES See page 236 for parts and accessories
Typical Application
Model
Rated Output
Evaporation Rate
Sq. Ft.
Sq. Ft.
Sq. Ft.
Type
Number
Gallons per Day
Gallons per Hour
Avg. House
Tight House Loose House
Drum Bypass
HDT260017.0
0.71
2,575
4,0451,845
Bypass Flow-Thru
HFT210014.0
0.58
2,121
3,3331,627
Bypass Flow-Thru
HFT270018.0
0.75
2,725
4,2851,955
Fan Powered Flow-Thru
HFT2900FP19.0
0.79
2,880
4,525
2,065
Table calculations based on ARI 630
www.white-rodgers.com
51