advertisement
RETURN TO MAIN MENU
Ranger 305 D (CE)
For use with machines having Code Numbers:
11122, 11123, 11189, 11190
IM837-A
June, 2005
Safety Depends on You
Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thoughtful operation on your part. DO
NOT INSTALL, OPERATE OR
REPAIR THIS EQUIPMENT
WITHOUT READING THIS
MANUAL AND THE SAFETY
PRECAUTIONS CONTAINED
THROUGHOUT.
And, most importantly, think before you act and be careful.
EN 60974-1
OPERATOR’S MANUAL
Copyright © 2005 Lincoln Global Inc.
• World's Leader in Welding and Cutting Products •
• Sales and Service through Subsidiaries and Distributors Worldwide •
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com
i SAFETY
WARNING
CALIFORNIA PROPOSITION 65 WARNINGS
Diesel engine exhaust and some of its constituents are known to the State of California to cause cancer, birth defects, and other reproductive harm.
The Above For Diesel Engines
The engine exhaust from this product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
The Above For Gasoline Engines
ARC WELDING CAN BE HAZARDOUS. PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH.
KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.
Read and understand the following safety highlights. For additional safety information, it is strongly recommended that you purchase a copy of “Safety in Welding & Cutting - ANSI Standard Z49.1” from the American Welding Society, P.O. Box
351040, Miami, Florida 33135 or CSA Standard W117.2-1974. A Free copy of “Arc Welding Safety” booklet E205 is available from the Lincoln Electric Company, 22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.
BE SURE THAT ALL INSTALLATION, OPERATION, MAINTENANCE AND REPAIR PROCEDURES ARE
PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
FOR ENGINE powered equipment.
1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running.
____________________________________________________
1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
1.h. To avoid scalding, do not remove the radiator pressure cap when the engine is hot.
ELECTRIC AND
MAGNETIC FIELDS may be dangerous
____________________________________________________
1.c. Do not add the fuel near an open flame welding arc or when the engine is running.
Stop the engine and allow it to cool before refueling to prevent spilled fuel from vaporizing on contact with hot engine parts and igniting. Do not spill fuel when filling tank. If fuel is spilled, wipe it up and do not start engine until fumes have been eliminated.
____________________________________________________
1.d. Keep all equipment safety guards, covers and devices in position and in good repair.Keep hands, hair, clothing and tools away from V-belts, gears, fans and all other moving parts when starting, operating or repairing equipment.
____________________________________________________
1.e. In some cases it may be necessary to remove safety guards to perform required maintenance. Remove guards only when necessary and replace them when the maintenance requiring their removal is complete.
Always use the greatest care when working near moving parts.
___________________________________________________
1.f. Do not put your hands near the engine fan.
Do not attempt to override the governor or idler by pushing on the throttle control rods while the engine is running.
2.a. Electric current flowing through any conductor causes localized Electric and Magnetic Fields (EMF). Welding current creates EMF fields around welding cables and welding machines
2.b. EMF fields may interfere with some pacemakers, and welders having a pacemaker should consult their physician before welding.
2.c. Exposure to EMF fields in welding may have other health effects which are now not known.
2.d. All welders should use the following procedures in order to minimize exposure to EMF fields from the welding circuit:
2.d.1. Route the electrode and work cables together - Secure them with tape when possible.
2.d.2. Never coil the electrode lead around your body.
2.d.3. Do not place your body between the electrode and work cables. If the electrode cable is on your right side, the work cable should also be on your right side.
___________________________________________________
1.g. To prevent accidentally starting gasoline engines while turning the engine or welding generator during maintenance work, disconnect the spark plug wires, distributor cap or magneto wire as appropriate.
2.d.4. Connect the work cable to the workpiece as close as possible to the area being welded.
2.d.5. Do not work next to welding power source.
Mar ‘95 i
ii
ELECTRIC SHOCK can kill.
3.a. The electrode and work (or ground) circuits are electrically “hot” when the welder is on.
Do not touch these “hot” parts with your bare skin or wet clothing. Wear dry, hole-free gloves to insulate hands.
3.b. Insulate yourself from work and ground using dry insulation.
Make certain the insulation is large enough to cover your full area of physical contact with work and ground.
In addition to the normal safety precautions, if welding must be performed under electrically hazardous conditions (in damp locations or while wearing wet clothing; on metal structures such as floors, gratings or scaffolds; when in cramped positions such as sitting, kneeling or lying, if there is a high risk of unavoidable or accidental contact with the workpiece or ground) use the following equipment:
• Semiautomatic DC Constant Voltage (Wire) Welder.
• DC Manual (Stick) Welder.
• AC Welder with Reduced Voltage Control.
3.c. In semiautomatic or automatic wire welding, the electrode, electrode reel, welding head, nozzle or semiautomatic welding gun are also electrically “hot”.
3.d. Always be sure the work cable makes a good electrical connection with the metal being welded. The connection should be as close as possible to the area being welded.
3.e. Ground the work or metal to be welded to a good electrical
(earth) ground.
3.f. Maintain the electrode holder, work clamp, welding cable and welding machine in good, safe operating condition. Replace damaged insulation.
3.g. Never dip the electrode in water for cooling.
3.h. Never simultaneously touch electrically “hot” parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welders.
3.i. When working above floor level, use a safety belt to protect yourself from a fall should you get a shock.
3.j. Also see Items 6.c. and 8.
SAFETY
ARC RAYS can burn.
4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
4.b. Use suitable clothing made from durable flame-resistant material to protect your skin and that of your helpers from the arc rays.
4.c. Protect other nearby personnel with suitable, non-flammable screening and/or warn them not to watch the arc nor expose themselves to the arc rays or to hot spatter or metal.
FUMES AND GASES can be dangerous.
5.a. Welding may produce fumes and gases hazardous to health. Avoid breathing these fumes and gases.When welding, keep your head out of the fume. Use enough ventilation and/or exhaust at the arc to keep fumes and gases away from the breathing zone. When welding with electrodes which require special ventilation such as stainless or hard facing (see instructions on container or MSDS) or on lead or cadmium plated steel and other metals or coatings which produce highly toxic fumes, keep exposure as low as possible and below Threshold Limit Values (TLV) using local exhaust or mechanical ventilation. In confined spaces or in some circumstances, outdoors, a respirator may be required. Additional precautions are also required when welding on galvanized steel.
5.b. Do not weld in locations near chlorinated hydrocarbon vapors coming from degreasing, cleaning or spraying operations.
The heat and rays of the arc can react with solvent vapors to form phosgene, a highly toxic gas, and other irritating pro- ducts.
5.c. Shielding gases used for arc welding can displace air and cause injury or death. Always use enough ventilation, especially in confined areas, to insure breathing air is safe.
5.d. Read and understand the manufacturer’s instructions for this equipment and the consumables to be used, including the material safety data sheet (MSDS) and follow your employer’s safety practices. MSDS forms are available from your welding distributor or from the manufacturer.
5.e. Also see item 1.b.
Mar ‘95 ii
iii SAFETY
WELDING SPARKS can cause fire or explosion.
6.a. Remove fire hazards from the welding area.
If this is not possible, cover them to prevent the welding sparks from starting a fire.
Remember that welding sparks and hot materials from welding can easily go through small cracks and openings to adjacent areas. Avoid welding near hydraulic lines. Have a fire extinguisher readily available.
6.b. Where compressed gases are to be used at the job site, special precautions should be used to prevent hazardous situations. Refer to “Safety in Welding and Cutting” (ANSI
Standard Z49.1) and the operating information for the equipment being used.
6.c. When not welding, make certain no part of the electrode circuit is touching the work or ground. Accidental contact can cause overheating and create a fire hazard.
6.d. Do not heat, cut or weld tanks, drums or containers until the proper steps have been taken to insure that such procedures will not cause flammable or toxic vapors from substances inside. They can cause an explosion even though they have been “cleaned”. For information, purchase “Recommended
Safe Practices for the Preparation for Welding and Cutting of
Containers and Piping That Have Held Hazardous
Substances”, AWS F4.1 from the American Welding Society
(see address above).
6.e. Vent hollow castings or containers before heating, cutting or welding. They may explode.
6.f. Sparks and spatter are thrown from the welding arc. Wear oil free protective garments such as leather gloves, heavy shirt, cuffless trousers, high shoes and a cap over your hair. Wear ear plugs when welding out of position or in confined places.
Always wear safety glasses with side shields when in a welding area.
6.g. Connect the work cable to the work as close to the welding area as practical. Work cables connected to the building framework or other locations away from the welding area increase the possibility of the welding current passing through lifting chains, crane cables or other alternate circuits. This can create fire hazards or overheat lifting chains or cables until they fail.
6.h. Also see item 1.c.
CYLINDER may explode if damaged.
7.a. Use only compressed gas cylinders containing the correct shielding gas for the process used and properly operating regulators designed for the gas and pressure used. All hoses, fittings, etc. should be suitable for the application and maintained in good condition.
7.b. Always keep cylinders in an upright position securely chained to an undercarriage or fixed support.
7.c. Cylinders should be located:
• Away from areas where they may be struck or subjected to physical damage.
• A safe distance from arc welding or cutting operations and any other source of heat, sparks, or flame.
7.d. Never allow the electrode, electrode holder or any other electrically “hot” parts to touch a cylinder.
7.e. Keep your head and face away from the cylinder valve outlet when opening the cylinder valve.
7.f. Valve protection caps should always be in place and hand tight except when the cylinder is in use or connected for use.
7.g. Read and follow the instructions on compressed gas cylinders, associated equipment, and CGA publication P-l,
“Precautions for Safe Handling of Compressed Gases in
Cylinders,” available from the Compressed Gas Association
1235 Jefferson Davis Highway, Arlington, VA 22202.
FOR ELECTRICALLY powered equipment.
8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment.
8.b. Install equipment in accordance with the U.S. National
Electrical Code, all local codes and the manufacturer’s recommendations.
8.c. Ground the equipment in accordance with the U.S. National
Electrical Code and the manufacturer’s recommendations.
iii
Mar ‘95
iv SAFETY
PRÉCAUTIONS DE SÛRETÉ
Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suivantes: iv
5. Toujours porter des lunettes de sécurité dans la zone de soudage. Utiliser des lunettes avec écrans lateraux dans les zones où l’on pique le laitier.
6. Eloigner les matériaux inflammables ou les recouvrir afin de prévenir tout risque d’incendie dû aux étincelles.
Sûreté Pour Soudage A L’Arc
1. Protegez-vous contre la secousse électrique:
7. Quand on ne soude pas, poser la pince à une endroit isolé de la masse. Un court-circuit accidental peut provoquer un
échauffement et un risque d’incendie.
a. Les circuits à l’électrode et à la piéce sont sous tension quand la machine à souder est en marche. Eviter toujours tout contact entre les parties sous tension et la peau nue ou les vétements mouillés. Porter des gants secs et sans trous pour isoler les mains.
b. Faire trés attention de bien s’isoler de la masse quand on soude dans des endroits humides, ou sur un plancher metallique ou des grilles metalliques, principalement dans les positions assis ou couché pour lesquelles une grande partie du corps peut être en contact avec la masse.
c. Maintenir le porte-électrode, la pince de masse, le câble de soudage et la machine à souder en bon et sûr état defonctionnement.
d.Ne jamais plonger le porte-électrode dans l’eau pour le refroidir.
e. Ne jamais toucher simultanément les parties sous tension des porte-électrodes connectés à deux machines à souder parce que la tension entre les deux pinces peut être le total de la tension à vide des deux machines.
f. Si on utilise la machine à souder comme une source de courant pour soudage semi-automatique, ces precautions pour le porte-électrode s’applicuent aussi au pistolet de soudage.
8. S’assurer que la masse est connectée le plus prés possible de la zone de travail qu’il est pratique de le faire. Si on place la masse sur la charpente de la construction ou d’autres endroits éloignés de la zone de travail, on augmente le risque de voir passer le courant de soudage par les chaines de levage, câbles de grue, ou autres circuits. Cela peut provoquer des risques d’incendie ou d’echauffement des chaines et des câbles jusqu’à ce qu’ils se rompent.
9. Assurer une ventilation suffisante dans la zone de soudage.
Ceci est particuliérement important pour le soudage de tôles galvanisées plombées, ou cadmiées ou tout autre métal qui produit des fumeés toxiques.
10. Ne pas souder en présence de vapeurs de chlore provenant d’opérations de dégraissage, nettoyage ou pistolage. La chaleur ou les rayons de l’arc peuvent réagir avec les vapeurs du solvant pour produire du phosgéne (gas fortement toxique) ou autres produits irritants.
11. Pour obtenir de plus amples renseignements sur la sûreté, voir le code “Code for safety in welding and cutting” CSA
Standard W 117.2-1974.
2. Dans le cas de travail au dessus du niveau du sol, se protéger contre les chutes dans le cas ou on recoit un choc. Ne jamais enrouler le câble-électrode autour de n’importe quelle partie du corps.
3. Un coup d’arc peut être plus sévère qu’un coup de soliel, donc: a. Utiliser un bon masque avec un verre filtrant approprié ainsi qu’un verre blanc afin de se protéger les yeux du rayonnement de l’arc et des projections quand on soude ou quand on regarde l’arc.
b. Porter des vêtements convenables afin de protéger la peau de soudeur et des aides contre le rayonnement de l‘arc.
c. Protéger l’autre personnel travaillant à proximité au soudage à l’aide d’écrans appropriés et non-inflammables.
PRÉCAUTIONS DE SÛRETÉ POUR
LES MACHINES À SOUDER À
TRANSFORMATEUR ET À
REDRESSEUR
1. Relier à la terre le chassis du poste conformement au code de l’électricité et aux recommendations du fabricant. Le dispositif de montage ou la piece à souder doit être branché à une bonne mise à la terre.
2. Autant que possible, I’installation et l’entretien du poste seront effectués par un électricien qualifié.
4. Des gouttes de laitier en fusion sont émises de l’arc de soudage. Se protéger avec des vêtements de protection libres de l’huile, tels que les gants en cuir, chemise épaisse, pantalons sans revers, et chaussures montantes.
3. Avant de faires des travaux à l’interieur de poste, la debrancher à l’interrupteur à la boite de fusibles.
4. Garder tous les couvercles et dispositifs de sûreté à leur place.
Mar. ‘93
v SAFETY v
vi
SAFETY
vi
c/o Balmes, 89 - 80 2a
08008 Barcelona
SPAIN
Measured sound power level:
LWA 98 dB (net power Pel = 7.5kW)
LWA 96 dB (net power Pel = 7.5k W)
Dario Gatti,
26 April 2005
RANGER 305D (CE)
vii
SAFETY
vii
RANGER 305D (CE)
viii
SAFETY
viii
RANGER 305D (CE)
ix
Thank You
ix
for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product
••• as much pride as we have in bringing this product to you!
Please Examine Carton and Equipment For Damage Immediately
When this equipment is shipped, title passes to the purchaser upon receipt by the carrier. Consequently, Claims for material damaged in shipment must be made by the purchaser against the transportation company at the time the shipment is received.
Please record your equipment identification information below for future reference. This information can be found on your machine nameplate.
Product _________________________________________________________________________________
Model Number ___________________________________________________________________________
Code Number or Date Code_________________________________________________________________
Serial Number____________________________________________________________________________
Date Purchased___________________________________________________________________________
Where Purchased_________________________________________________________________________
Whenever you request replacement parts or information on this equipment, always supply the information you have recorded above. The code number is especially important when identifying the correct replacement parts.
On-Line Product Registration
- Register your machine with Lincoln Electric either via fax or over the Internet.
• For faxing: Complete the form on the back of the warranty statement included in the literature packet accompanying this machine and fax the form per the instructions printed on it.
• For On-Line Registration: Go to our WEB SITE at www.lincolnelectric.com. Choose “Quick Links” and then
“Product Registration”. Please complete the form and submit your registration.
Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference. Pay particular attention to the safety instructions we have provided for your protection.
The level of seriousness to be applied to each is explained below:
WARNING
This statement appears where the information must be followed exactly to avoid serious personal injury or
loss of life.
CAUTION
This statement appears where the information must be followed to avoid minor personal injury or damage to
this equipment.
x
TABLE OF CONTENTS
Page
Installation.......................................................................................................................Section A
Technical Specifications .......................................................................................................A-1
Safety Precautions ........................................................................................................A-2
Location and Ventilation ................................................................................................A-2
Stacking ........................................................................................................................A-2
Angle of Operation ........................................................................................................A-2
Lifting.............................................................................................................................A-2
High Altitude Operation .................................................................................................A-2
High Temperature Operation ........................................................................................A-2
Cold Weather Operation ...............................................................................................A-2
Towing...........................................................................................................................A-3
Vehicle Mounting...........................................................................................................A-3
Pre-Operation Engine Service..............................................................................................A-3
Oil ..................................................................................................................................A-3
Fuel ...............................................................................................................................A-3
Engine Coolant..............................................................................................................A-4
Battery Connections ......................................................................................................A-4
Muffler Outlet Pipe ........................................................................................................A-4
Spark Arrester ...............................................................................................................A-4
Remote Control .............................................................................................................A-4
Electrical Connections ..........................................................................................................A-4
Machine Grounding .......................................................................................................A-4
Welding Terminals ........................................................................................................A-5
Welding Output Cables .................................................................................................A-5
Cable Installation...........................................................................................................A-5
Auxiliary Power ....................................................................................................................A-5
Standby Power Connections ................................................................................................A-5
Connection of Lincoln Electric Wire Feeders................................................................A-6,A-7
________________________________________________________________________________
Operation.........................................................................................................................Section B
Safety Precautions ..............................................................................................................B-1
General Description..............................................................................................................B-1
For Auxiliary Power ..............................................................................................................B-1
Engine Operation..................................................................................................................B-1
Break in Period .....................................................................................................................B-1
Add Fuel ...............................................................................................................................B-1
Fuel ......................................................................................................................................B-1
Welder Controls ............................................................................................................B-2
Engine Controls.............................................................................................................B-3
Starting and Stopping the Engine ...........................................................................B-3, B4
Stopping .......................................................................................................................B-4
Welding Operation................................................................................................................B-5
Duty Cycle .....................................................................................................................B-5
Constant Current (Stick) Welding..................................................................................B-5
Downhill Pipe (Stick) Welding .......................................................................................B-5
Tig Welding ...................................................................................................................B-5
Typical Current Ranges for Tungsten Electrodes .........................................................B-5
Wire Welding-CV...........................................................................................................B-6
Arc Gouging ..................................................................................................................B-6
Auxiliary Power .............................................................................................................B-6
________________________________________________________________________________
Accessories .....................................................................................................Section C
Field Installed Options / Accessories ...............................................................................C-1
________________________________________________________________________________
x
xi
TABLE OF CONTENTS
Maintenance......................................................................................................Section D
Safety Precautions ................................................................................................D-1
Routine Maintenance ............................................................................................D-1
Engine Maintenance Components ........................................................................D-1
Kubota Diesel Engine ............................................................................................D-1
Engine Oil Change ..........................................................................................D-2
Engine Oil Refill Capacities.............................................................................D-2
Engine Oil Filter Change .................................................................................D-2
Air Cleaner Service .........................................................................................D-2
Service Instructions And Installation Tips for Engine Air Filter .......................D-3
Cooling System .....................................................................................................D-4
Fan Belt...........................................................................................................D-4
Fuel .................................................................................................................D-4
Bleeding the Fuel System ...............................................................................D-4
Fuel Filter ........................................................................................................D-5
Engine Adjustment ..........................................................................................D-5
Battery Maintenance .......................................................................................D-5
Servicing Optional Spark Arrestor ...................................................................D-5
Welder / Generator Maintenance ........................................................................D-6
Storage ...........................................................................................................D-6
Cleaning ..........................................................................................................D-6
Brush Removal and Replacement ..................................................................D-6
________________________________________________________________________
Troubleshooting ..............................................................................................Section E
How to Use Troubleshooting Guide.......................................................................E-1
Troubleshooting Guide.............................................................................E-2 thru E-6
________________________________________________________________________
Diagrams and Dimension Print ......................................................................Section F
________________________________________________________________________
Parts List ..................................................................................................................P494
________________________________________________________________________
xi
A-1
INSTALLATION
TECHNICAL SPECIFICATIONS - RANGER 305D (CE)
Make/Model Description
INPUT - DIESEL ENGINE
Speed (RPM) Displacement cu. in. (cu. cm.)
A-1
Starting
System
Capacities
3 cylinder, 4 stroke
15.9 HP
Kubota (3)
(12 KW)
Net intermittent
D722 3000 RPM naturally aspirated water cooled
Diesel engine
Welding Process
DC Constant Current
DC Pipe Current
Touch-Start™TIG
DC Constant Voltage
Full Load 3000
Low Idle 2200
43.88(789)
High Idle 3100 Bore x Stroke inch (mm)
2.64 x 2.68
(67 x 68 mm)
12VDC Battery & Fuel: starter 45L (12 US.gal.)
Oil:
3.2L(3.4 US. Qts.)
(Group 58; 550 Radiator Coolant: cold crank amps) 3.6L(3.85 U Qts)
Battery Charger
(3.6L)
RATED OUTPUT @ 40° C (104° F) - WELDER
Welding Output
Current/Voltage/Duty Cycle
250A / 30V / 100%
250A / 30V / 100%
250A / 20V / 100%
250A / 27V / 100%
Output Range
20 TO 305 AMPS
40 TO 300 AMPS
20 TO 250 AMPS
14 TO 29 VOLTS
Max. Weld OCV
@Rated Load RPM
60 Volts
RATED OUTPUT @ 40° C (104° F) - GENERATOR
Auxiliary Power (1)
8,500 Watts Peak, / 8,000 Watts Continuous, 50 Hz 230/400 Volts - 3 Phase
Sound Levels
Sound Power: 98 dB Lwa
HEIGHT WIDTH
PHYSICAL DIMENSIONS
DEPTH
909mm 546mm 1524mm
30.0 in.
(2) 21.50 in 60.0 in.
WEIGHT
341kg. (752lbs.)
ENGINE
LUBRICATION EMISSIONS
Full Pressure Certified to
FUEL SYSTEM
Electric Fuel Pump(Codes 11122, 11123), Mechanical with Full Flow Filter EPA Tier I Fuel Pump(Codes 11189, 11190), Auto air bleed
GOVERNOR
Mechanical Governor system Electric shutoff solenoid Indirect fuel injector.
AIR CLEANER ENGINE IDLER
Single Element Automatic Idler
MUFFLER
Low noise Muffler:
ENGINE PROTECTION
Shutdown on low oil
Top outlet can be rotated. pressure & engine
Made from long life, aluminized steel.
temperature
ENGINE WARRANTY: 2 year complete (parts and labor) 3rd. year major components (parts and labor) (3)
MODEL NUMBER
Receptacles
Residual Current Device (RCD)
Circuit Breakers (Thermal/Magnetic)
K2279-1 (UK)
400V (3 Ph) x 1
230V (1 Ph) x 1
115V x 1 (4)
14 Pin Connector
6 Pin Connector
4-pole, 25 Amp
(30mA trip current)
3 Phase, 20 Amp x 1
1 Phase, 15 Amp x 5
K2279-2 (EUROPE)
400V (3 Ph) x 1
230V (1 Ph) x 2
14 Pin Connector
6 Pin Connector
4-pole, 25 Amp
(30mA trip current)
3 Phase, 20 Amp x 1
1 Phase, 15 Amp x 4
(1) Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced.
(2) To top of enclosure, add 152mm (6 “) to top of exhaust elbow.
(3) Engine warranty may vary outside of the USA. (See Engine warranty for details)
(4) Center-Tapped to ground.
RANGER 305D (CE)
A-2
SAFETY PRECAUTIONS
WARNING
INSTALLATION
A-2
LIFTING
The machine weighs approximately 374 kg. (824 lbs) with a full tank of fuel. A lift bail is mounted to the machine and should always be used when lifting the machine.
Do not attempt to use this equipment until you have thoroughly read the engine manufacturer’s manual supplied with your welder. It includes important safety precautions, detailed engine starting, operating and maintenance instructions, and parts lists.
------------------------------------------------------------------------
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts or electrode with skin or wet clothing.
• Insulate yourself from work and ground
• Always wear dry insulating gloves.
------------------------------------------------------------------------
ENGINE EXHAUST can kill.
• Use in open, well ventilated areas or vent exhaust outside.
------------------------------------------------------------------------
WARNING
• Lift only with equipment of adequate lifting capacity.
• Be sure machine is stable when lifting.
• Do not lift this machine using lift bail if it is equipped with a heavy accessory such as trailer or gas cylinder.
FALLING • Do not lift machine if lift bail is
EQUIPMENT can damaged.
cause injury. • Do not operate machine while suspended from lift bail.
--------------------------------------------------------------------------------
MOVING PARTS can injure.
• Do not operate with doors open or guards off.
• Stop engine before servicing.
• Keep away from moving parts.
------------------------------------------------------------------------
See additional warning information at front of this operator’s manual.
Only qualified personnel should install, use, or service this equipment.
HIGH ALTITUDE OPERATION
At higher altitudes, output derating may be necessary. For maximum rating, derate the machine 2.5% to 3.5% for every 305m
(1000ft.). Due to new EPA and other local emissions regulations, modifications to the engine for high altitude are restricted within the United States and some European Countries. Use above 1828m (6000 ft.) may be limited due to poor engine performance or excessive exhaust smoke. An authorized Kubota engine field service shop should be contacted to determine if any adjustments can be made for operation in higher elevations locally.
LOCATION AND VENTILATION
The welder should be located to provide an unrestricted flow of clean, cool air to the cooling air inlets and to avoid restricting the cooling air outlets. Also, locate the welder so that the engine exhaust fumes are properly vented to an outside area.
HIGH TEMPERATURE OPERATION
At temperatures above 40°C,welder output derating is necessary. For maximum output ratings, derate the welder output 2 volts for every 10°C above 40°C.
Cold weather starting:
STACKING
RANGER 305D (CE) machines cannot be stacked.
ANGLE OF OPERATION
Engines are designed to run in the level condition which is where the optimum performance is achieved.
The maximum angle of continuous operation is 20 degrees in all directions, 35 degrees Intermittent (less than 10 minutes continuous) in all directions. If the engine is to be operated at an angle, provisions must be made for checking and maintaining the oil level at the normal (FULL) oil capacity in the crankcase.
With a fully charged battery and the proper oil, the engine should start satisfactorily down to about 15°C
(5°F). If the engine must be frequently started at or below -5°C (23°F), it may be desirable to install coldstarting aides. The use of No. 1D diesel fuel is recommended in place of No. 2D at temperatures below
-5°C (23°F). Allow the engine to warm up before applying a load or switching to high idle.
WARNING
When operating the welder at an angle, the effective fuel capacity will be slightly less than the specified 45 liters (12 gallons).
Note: Extreme cold weather starting may require longer glow plug operation.
Under no conditions should ether or other starting fluids be used!
------------------------------------------------------------------------
RANGER 305D (CE)
A-3
INSTALLATION
TOWING
Check with distributor for the recommended trailer for use with this equipment for road, in-plant and yard towing by a vehicle. If the user adapts a non-Lincoln trailer, he must assume responsibility that the method of attachment and usage does not result in a safety hazard nor damage the welding equipment. Some of the factors to be considered are as follows:
WARNING
A-3
PRE-OPERATION ENGINE SERVICE
READ the engine operating and maintenance instructions supplied with this machine.
1. Design capacity of trailer vs. weight of Lincoln equipment and likely additional attachments.
2. Proper support of, and attachment to, the base of the welding equipment so there will be no undue stress to the framework.
• Stop engine and allow to cool before fueling
• Do not smoke when fueling
• Fill fuel tank at a moderate rate and do not overfill.
• Wipe up spilled fuel and allow fumes to clear before starting engine
• Keep sparks and flame away from tank.
------------------------------------------------------------------------
3. Proper placement of the equipment on the trailer to insure stability side to side and front to back when being moved and when standing by itself while being operated or serviced.
4. Typical conditions of use, i.e., travel speed; roughness of surface on which the trailer will be operated; environmental conditions; like maintenance.
5. Conformance with laws in nation / region to be used.
VEHICLE MOUNTING
WARNING
OIL
The machine is shipped with the engine crankcase filled with high quality SAE 10W-30 Oil that meets classification CG-4 or CH-4 for diesel engines. Check the oil level before starting the engine. If it is not up to the full mark on the dip stick, add oil as required.
Check the oil level every four hours of running time during the first 50 running hours. Refer to the engine
Operator’s Manual for specific oil recommendations and break-in information. The oil change interval is dependent on the quality of the oil and the operating environment. Refer to the Engine Operator’s Manual for more details on the proper service and maintenance intervals.
Improperly mounted concentrated loads may cause unstable vehicle handling and tires or other components to fail.
• Only transport this Equipment on serviceable vehicles which are rated and designed for such loads.
• Distribute, balance and secure loads so vehicle is stable under conditions of use.
• Do not exceed maximum rated loads for components such as suspension, axles and tires.
• Mount equipment base to metal bed or frame of vehicle.
• Follow vehicle manufacturer’s instructions.
------------------------------------------------------------------------
FUEL
USE DIESEL FUEL ONLY
WARNING
• Fill the fuel tank with clean, fresh fuel. The capacity of the tank is, about 45 ltr.’s (12 Gal.’s).
WARNING
NOTE: A fuel shut off valve is located on the prefilter/sediment filter. Which should be in the closed position when the welder is not operated for extended periods of time.
------------------------------------------------------------------------
RANGER 305D (CE)
A-4
ENGINE COOLING SYSTEM
WARNING
INSTALLATION
Air to cool the engine is drawn in the base sides and exhaust through radiator & case back. It is important that the intake and exhaust air is not restricted. Allow a minimum clearance of 0.6m (2 feet) from the case back and 40cm (16”) from
either side of the base to a vertical surface.
------------------------------------------------------------------------
BATTERY CONNECTION
A-4
REMOTE CONTROL
The machine is equipped with a 6-pin and a 14-pin connector. The 6-pin connector is for connecting the
K857 or K857-1 Remote Control or for TIG welding, the K870 foot Amptrol or the K963-3 hand Amptrol.
When in the CC-STICK, DOWNHILL PIPE, or CV-
WIRE modes and when a remote control is connected to the 6-pin Connector, the auto-sensing circuit automatically switches the OUTPUT control from control at the welder to remote control.
CAUTION
When in TOUCH START TIG mode and when a
Amptrol is connected to the 6-Pin Connector, the
OUTPUT dial is used to set the maximum current range of the CURRENT CONTROL of the Amptrol.
Use caution as the electrolyte is a strong acid that can burn skin and damage eyes.
------------------------------------------------------------------------
The machine is shipped with the negative battery cable disconnected. Make certain that the RUN-STOP switch is in the STOP position. Attach the negative battery cable to the negative battery terminal and tighten using a 13mm socket or wrench. It may be helpful to remove the coolant over-fill bottle. Pull up on bottle to remove from bracket.
The 14-pin connector is used to directly connect a wire feeder control cable. In the CV-WIRE mode, when the control cable is connected to the 14-pin connector, the auto-sensing circuit automatically makes the Output
Control inactive and the wire feeder voltage control active
WARNING
NOTE: This machine is furnished with a wet charged battery; if unused for several months, the battery may require a booster charge. Be careful to charge the battery with the correct polarity.
NOTE: When a wire feeder with a built in welding voltage control is connected to the 14-pin connector, do not connect anything to the 6-pin connector.
------------------------------------------------------------------------
ELECTRICAL CONNECTIONS
MUFFLER OUTLET PIPE
Using the clamp provided secure the outlet pipe to the outlet tube with the pipe positioned such that it will direct the exhaust to the radiator end of the machine.
Tighten using an adjustable wrench.
MACHINE GROUNDING
Because this portable engine driven welder creates its own power, it is not necessary to connect its frame to an earth ground, unless the machine is connected to premises wiring (home, shop, etc.)
SPARK ARRESTER
Some local laws may require that gasoline or diesel engines be equipped with exhaust spark arresters when they are operated in certain locations where unarrested sparks may present a fire hazard. The standard muffler included with this welder does not qualify as a spark arrester. When required by local regulations, a suitable spark arrester, such as the
K1898-1 must be installed and properly maintained.
To prevent dangerous electric shock, other equipment to which this engine driven welder supplies power must:
WARNING
WARNING
An incorrect spark arrestor may lead to damage to the engine or adversely affect performance.
------------------------------------------------------------------------
• Be grounded to the frame of the welder using a grounded type plug.
• Be double insulated.
• Do not ground the machine to a pipe that carries explosive or combustible material.
------------------------------------------------------------------------
RANGER 305D (CE)
A-5
INSTALLATION
When this welder is mounted on a truck or trailer, its frame must be electrically bonded to the metal frame of the vehicle. Use a #8 or larger copper wire connected between the machine grounding stud and the frame of the vehicle. When this engine driven welder is connected to premises wiring such as that in a home or shop, its frame must be connected to the system earth ground. See further connection instructions in the section entitled "Standby Power Connections" .
In general, if the machine is to be grounded, it should be connected with a #8 or larger copper wire to a solid earth ground such as a metal water pipe going into the ground for at least ten feet and having no insulated joints, or to the metal framework of a building which has been effectively grounded.
CAUTION
A-5
CABLE INSTALLATION
Install the welding cables to your machine as follows:
1. The diesel engine must be OFF to install welding cables.
2. Remove the flanged nuts from the output terminals.
3. Connect the electrode holder and work cables to the weld output terminals. The terminals are identified on the case front.
4. Tighten the flanged nuts securely.
5. Be certain that the metal piece you are welding
(the “work”) is properly connected to the work clamp and cable.
6. Check and tighten the connections periodically.
A machine grounding stud marked with the symbol is provided on the front of the welder.
WELDING TERMINALS
The machine is equipped with a toggle switch for selecting "hot" welding terminal when in the "WELD
TERMINALS ON" position or "cold" welding terminal when in the "REMOTE" position.
• Loose connections will cause the output terminals to overheat. The terminals may eventually melt.
• Do not cross the welding cables at the output terminal connection. Keep the cables isolated and separate from one another.
-----------------------------------------------------------------------
AUXILIARY POWER
WELDING OUTPUT CABLES
With the engine off connect the electrode and work cables to the output studs. The welding process dictates the polarity of the electrode cable. These connections should be checked periodically and tightened with a 19mm wrench.
The auxiliary power capacity is 8500 watts Peak,
8,000 Watts Continuous of 50 Hz, three phase power. The auxiliary power capacity rating in watts is equivalent to volt-amperes at unity power factor. The max permissible current of the 400 VAC output is 20 amps. Output voltage is within ± 10% at all loads up to the rated capacity.
Table A.1 lists recommended cable sizes and lengths for rated current and duty cycle. Length refers to the distance from the welder to the work and back to the welder. Cable diameters are increased for long cable lengths to reduce voltage drops.
TABLE A-1
TOTAL COMBINED LENGTH OF
ELECTRODE AND WORK CABLES
Cable Length
0-30 meters (0-100Ft.)
Cable Size for
305 Amps
100% Duty Cycle
1 / 0 AWG
2 / 0 AWG
30-46 meters (100-150 Ft.)
46-61 meters (150-200 Ft.) 3 / 0 AWG
STANDBY POWER CONNECTIONS
The machine is suitable for temporary, standby or emergency power using the engine manufacturer’s recommended maintenance schedule.
The machine can be permanently installed as a standby power unit for 400 VAC, three phase, 20 amp service.
Connections must be made by a licensed electrician who can determine how the power can be adapted to the particular installation and comply with all applicable electrical codes.
• Take necessary steps to assure load is limited to the capacity of the RANGER 305D (CE).
WARNING
• Only a licensed, certified, trained electrician should install the machine to a premises or residential electrical system. Be certain that:
RANGER 305D (CE)
A-6
INSTALLATION
• The installation complies with the National
Electrical Code and all other applicable electrical codes.
• The premises is isolated and no feedback into the utility system can occur. Certain laws require the premises to be isolated before the generator is linked to the premises. Check your local requirements.
-----------------------------------------------------------------------
CONNECTION OF LINCOLN ELECTRIC
WIRE FEEDERS
Connection of LN-15 to the Ranger 305D
These connections instructions apply to both the LN-
15 Across The-Arc and Control Cable models. The
LN-15 has an internal contactor and the electrode is not energized until the gun trigger is closed. When the gun trigger is closed the wire will begin to feed and the welding process is started.
• Shut the welder off.
• For electrode Positive, connect the electrode cable to the "+" terminal of the welder and work cable to the "-" terminal of the welder. For electrode
Negative, connect the electrode cable "-" terminal of the welder and work cable to the "+" terminal of the welder.
WARNING
1. Shut the welder off.
A-6
Connection of the LN-25 to the RANGER 305D
(CE)
Shut off welder before making any electrical connections.
------------------------------------------------------------------------
The LN-25 with or without an internal contactor may be used with the RANGER 305D (CE). See the appropriate connection diagram in Section F.
NOTE: The LN-25 (K431) Remote Control Module and (K432) Remote Cable are not recommended for use with the RANGER 305D (CE).
2. For electrode Positive, connect the electrode cable from the LN-25 to the "+" terminal of the welder and work cable to the "-" terminal of the welder. For electrode Negative, connect the electrode cable from the LN-25 to the "-" terminal of the welder and work cable to the "+" terminal of the welder.
3. Attach the single lead from the front of the LN-25 to work using the spring clip at the end of the lead.
This is a control lead to supply current to the wire feeder motor; it does not carry welding current.
• Across The-Arc Model:
4. Set the MODE switch to the "CV-WIRE " position.
Attach the single lead from the front of the LN-15 to work using the spring clip at the end of the lead. This is a control lead to supply current to the wire feeder motor; it does not carry welding current.
5. Set the "WELD TERMINALS" switch to "WELD
TERMINALS ON"
Set the "WELD TERMINALS" switch to "WELD TER-
MINALS ON".
6. Set the "ARC CONTROL" knob to "0" initially and adjust to suit.
• Control Cable Model:
Connect Control Cable between Engine Welder and
Feeder.
Set the MODE switch to the "CV-WIRE " position.
7. Set the "IDLE" switch to the "AUTO" position.
When not welding, the RANGER 305D (CE) engine will be at the low idle speed. If you are using an LN-25 with an internal contactor, the electrode is not energized until the gun trigger is closed.
Set the "WELD TERMINALS" switch to "REMOTELY
CONTROLLED".
Set the "WIRE FEEDER VOLTMETER" switch to either "+" or "-" as required by the electrode polarity being used.
Set the "ARC CONTROL" knob to "0" initially and adjust to suit.
Set the "IDLE" switch to the "AUTO" position. 0
8. When the gun trigger is closed, the current sensing circuit will cause the RANGER 305D (CE) engine to go to the high idle speed, the wire will begin to feed and the welding process started. When welding is stopped, the engine will revert to low idle speed after approximately 12 seconds unless welding is resumed.
CAUTION
If you are using an LN-25 without an internal contactor, the electrode will be energized when the
RANGER 305D (CE) is started.
------------------------------------------------------------------------
RANGER 305D
A-7
INSTALLATION
Connection of LN-742 and Cobramatic to RANGER
305D (CE)
• Shut the welder off.
• Connect per instructions on the appropriate connection diagram in Section F.
Connection of PRINCE XL SPOOL GUN to the
RANGER 305D (CE)
Connection of the Prince XL Spool Gun requires the use of the K1849-1 Adapter Module.
• Shut the Welder off.
• For electrode Positive, connect the electrode cable to the "+" terminal of the welder and work cable to the "-" terminal of the welder. For electrode
Negative, connect the electrode cable "-" terminal of the welder and work cable to the "+" terminal of the welder.
• Connect the Control Cable of the Spool Gun to the
Adapter Module and connect the Control Cable of the Adapter Module to the Welder.
• Connect the Gas Hose.
• Set the MODE switch to the "CV-WIRE " position.
• Set the "WELD TERMINALS" switch to "WELD
TERMINALS ON".
• Set the "ARC CONTROL" knob to "0" initially and adjust to suit.
• Set the “IDLE” switch to the “HIGH” position.
A-7
RANGER 305D (CE)
B-1
SAFETY PRECAUTIONS
WARNING
FOR AUXILIARY POWER:
OPERATION
B-1
• Check radiator for proper coolant level. (Fill if necessary).
• See Engine Owner’s Manual for specific oil and coolant recommendations.
ADD FUEL
Do not attempt to use this equipment until you have thoroughly read the engine manufacturer’s manual supplied with your welder. It includes important safety precautions, detailed engine starting, operating and maintenance instructions, and parts lists.
------------------------------------------------------------------------
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts or electrode with skin or wet clothing.
• Insulate yourself from work and ground
• Always wear dry insulating gloves.
• Always operate the welder with the hinged door closed and the side panels in place.
• Read carefully the Safety Precautions page before operating this machine. Always follow these and any other safety procedures included in this manual and in the Engine Instruction
Manual.
GENERAL DESCRIPTION
The RANGER 305D (CE) is a diesel engine powered
DC multi-process welding power source and AC power generator. The engine drives a generator that supplies three phase power for the DC welding circuit and three phase and single phase power for the AC auxiliary outlets. The DC welding control system uses state of the art Chopper Technology (CT TM ) for superior welding performance.
Start the engine and set the IDLER control switch to the desired operating mode. Full power is available regardless of the welding control settings providing no welding current is being drawn.
ENGINE OPERATION
Before Starting the Engine:
• Be sure the machine is on a level surface.
• Open top & side engine doors and remove the engine oil dipstick and wipe it with a clean cloth.
Reinsert the dipstick and check the level on the dipstick.
• Add oil (if necessary) to bring the level up to the full mark. Do not overfill. Close engine door.
WARNING
• Stop engine while fueling.
• Do not smoke when fueling.
• Keep sparks and flame away from tank.
• Do not leave unattended while fueling.
DIESEL FUEL
can cause fire.
• Wipe up spilled fuel and allow fumes to clear before starting engine.
• D o n o t o v e r f i l l t a n k , f u e l expansion may cause overflow.
DIESEL FUEL ONLY
------------------------------------------------------------------------
• Remove the fuel tank cap.
• Fill the tank approximately 4 inches (100mm) from the top of the filler neck to allow for fuel expansion
(observe the fuel gauge while filling). DO NOT FILL
THE TANK TO THE POINT OF OVERFLOW.
• Replace the fuel cap and tighten securely.
• See Engine Owner’s Manual for specific fuel recommendations.
BREAK-IN PERIOD
Any engine will use a small amount of oil during its
“break-in” period. For the diesel engine on the
RANGER 305D (CE), break-in is about 50 running hours.
Check the oil every four hours during break-in.
Change the oil after the first 50 hours of operation, every 100 hours thereafter. Change the oil filter at the second oil change.
CAUTION
During break-in, subject the RANGER 305D (CE) to moderate loads. Avoid long periods running at idle. Before stopping the engine, remove all loads and allow the engine to cool several minutes.
------------------------------------------------------------------------
RANGER 305D (CE)
B-2
1
2
OPERATION
16
17
15
14
B-2
3
13
12
11
4
10
9
8
5
7
WELDING CONTROLS
(Figure B.1)
FIGURE B.1
1. OUTPUT CONTROL:
The OUTPUT dial is used to preset the output voltage or current as displayed on the digital meters for the four welding modes. When in the CC-STICK, DOWNHILL PIPE or CV-WIRE modes and when a remote control is connected to the 6-Pin or 14-Pin Connector, the auto-sensing circuit automatically switches the
OUTPUT CONTROL from control at the welder to the remote control.
6
2. DIGITAL OUTPUT METERS
The digital meters allow the output voltage (CV-
WIRE mode) or current (CC-STICK, PIPE and TIG modes) to be set prior to welding using the OUT-
PUT control dial. During welding, the meter display the actual output voltage (VOLTS) and current
(AMPS). A memory feature holds the display of both meters on for seven seconds after welding is stopped. This allows the operator to read the actual current and voltage just prior to when welding was ceased.
While the display is being held the left-most decimal point in each display will be flashing. The accuracy of the meters is +/- 3%.
In the CV-WIRE mode, if the wire feeder has voltage control capability, when the control cable is connected to the 14-Pin Connector, the auto-sensing circuit automatically makes OUTPUT CON-
TROL inactive and the wire feeder voltage control active.
When in the TOUCH START TIG mode and when a
Amptrol is connected to the 6-Pin Connector, the
OUTPUT control is used to set the maximum current range of the CURRENT CONTROL of the
Amptrol.
3. WELD MODE SELECTOR SWITCH:
(Provides four selectable welding modes)
CV-WIRE
DOWNHILL PIPE
CC-STICK
TOUCH START TIG
RANGER 305D (CE)
B-3
OPERATION
4. ARC CONTROL
: The ARC CONTROL dial is active in the CV-WIRE, CC-STICK and DOWNHILL PIPE modes, and has different functions in these modes. This control is not active in the TIG mode.
B-3
10. WIRE FEEDER VOLTMETER SWITCH:
Matches the polarity of the wire feeder voltmeter to the polarity of the electrode.
ENGINE CONTROLS: (Figure B.2)
CC-STICK mode: In this mode, the ARC CONTROL dial sets the short circuit current (arc-force) during stick welding to adjust for a soft or crisp arc. Increasing the dial from –10
(soft) to +10 (crisp) increases the short circuit current and prevents sticking of the electrode to the plate while welding.
This can also increase spatter. It is recommended that the
ARC CONTROL be set to the minimum number without electrode sticking. Start with a setting at 0.
11. RUN/STOP SWITCH
- RUN position energizes the engine prior to starting. STOP position stops the engine.
The oil pressure interlock switch prevents battery drain if the switch is left in the RUN position and the engine is not operating.
DOWNHILL PIPE mode: In this mode, the ARC CONTROL dial sets the short circuit current (arc-force) during stick welding to adjust for a soft or a more forceful digging arc
(crisp). Increasing the number from –10 (soft) to +10 (crisp) increases the short circuit current which results in a more forceful digging arc. Typically a forceful digging arc is preferred for root and hot passes. A softer arc is preferred for fill and cap passes where weld puddle control and deposition ("stacking" of iron) are key to fast travel speeds. It is recommended that the ARC CONTROL be set initially at 0.
CV-WIRE mode: In this mode, turning the ARC CONTROL clock wise from –10 (soft) to +10 (crisp) changes the arc from soft and washed-in to crisp and narrow. It acts as an inductance/pinch control. The proper setting depends on the procedure and operator preference. Start with a setting of 0.
12. GLOW PLUG PUSH BUTTON
-
• When pushed activates the glow plugs as well as the electric fuel pump for quick starting. Glow plug should not be activated for more than 20 seconds continuously.(For Codes 11122, 11123 )
• AUTO BLEED FUNCTION – Air will automatically bleed from the fuel system by simply pushing the
GLOW PLUG BUTTON. It is generally not required to crack open fittings in the fuel system to bleed air from the fuel system.(For Codes 11122, 11123)
• When pushed activates the glow plugs. Glow plug should not be activated for more than 20 seconds continuously.(For Codes 11189, 11190)
5. WELD OUTPUT TERMINALS WITH FLANGE
NUT:
Provides a connection point for the electrode and work cables.
13. START PUSH BUTTON
-
Energizes the starter motor to crank engine.
6. GROUND STUD:
Provides a connection point for connecting the machine case to earth ground.
14. IDLER SWITCH
- Has two positions as follows:
1) In the HIGH position, the engine runs at the high idle speed controlled by the engine governor.
2) In the AUTO position, the idler operates as follows:
7. 14-PIN CONNECTOR:
trol cables to the RANGER 305D (CE). Includes contactor closure circuit, auto-sensing remote control circuit, and 42V power. The remote control circuit operates the same as the
6 Pin connector.
Note: The 14-pin connector does not include 120V.
8. 6-PIN CONNECTOR:
For attaching wire feeder con-
For attaching optional remote control equipment. Includes auto-sensing remote control circuit.
9. WELD TERMINALS SWITCH:
In the WELD TERMI-
NALS ON position, the output is electrically hot all the time.
In the REMOTELY CONTROLLED position, the output is controlled by a wire feeder or amptrol device, and is electrically off until a remote switch is depressed.
RANGER 305D (CE)
• When switched from HIGH to AUTO or after starting the engine, the engine will operate at full speed for approximately 12 seconds and then go to low idle speed.
• When the electrode touches the work or power is drawn for lights or tools (approximately 100 Watts minimum), the engine accelerates and operates at full speed.
• When welding ceases or the AC power load is turned off, a fixed time delay of approximately 12 seconds starts. If the welding or AC power load is not restarted before the end of the time delay, the idler reduces the engine speed to low idle speed.
• The engine will automatically return to high idle speed when there is welding load or AC power load reapplied.
B-4
OPERATION
15. ELECTRIC FUEL GAUGE-
Provides accurate, reliable indication of how much fuel is in the tank
.
16. ENGINE HOUR METER
– Displays the total time that the engine has been running. This meter is useful for scheduling prescribed maintenance.
B-4
8. The engine will run at high idle speed for approximately 12 seconds and then drop to low idle speed.
Allow the engine to warm up at low idle for several minutes before applying a load and/or switching to high idle. Allow a longer warm up time in cold weather.
NOTE: If the unit fails to start repeat step 4 through step 7 after waiting 30 seconds
17. ENGINE PROTECTION LIGHT-
A warning indicator light for Low Oil Pressure and/or Coolant
Over Temperature. The light is off when the systems are functioning properly. The light turns on when the RUN-STOP switch is in the “ON” position prior to starting the engine. If the Engine
Protection or Battery Charging Lights do “not” turn off shortly after starting the engine shut off the engine immediately and determine the cause.
STARTING THE ENGINE
1. Remove all plugs connected to the AC power receptacles.
2. Set IDLER switch to AUTO.
CAUTION
• Do not allow the starter motor to run continuously for more than 20 seconds.
• Do not push the START button while the engine is running because this can damage the ring gear and/or the starter motor.
• IF the Engine Protection or Battery Charging
Lights do “not” turn off shortly after starting the engine shut off the engine immediately and deter mine the cause.
-----------------------------------------------------------------------
NOTE: When starting a RANGER 305D (CE) for the first time, or after and extended period of time of not operating, it will take longer than normal because the fuel pump has to fill the fuel system.
3. Set the RUN/STOP switch to RUN.
4. Press Glow Plug Button and hold 5 to 10 seconds.
STOPPING THE ENGINE
Remove all welding and auxiliary power loads and allow the engine to run at low idle speed for a few minutes to cool the engine.
5. Press and hold both the “Glow Plug” Button and
START button together until the engine starts or for up to 10 seconds.
STOP the engine by placing the RUN-STOP switch in the STOP position.
6. Release the engine START button immediately when the engine starts.
NOTE: A fuel shut off valve is located on the fuel prefilter. Turn on Fuel shut-off valve on the fuel pre-filter.
7. Release the glow plug button after the Engine
Protection Light turns off or after an additional 5 seconds maximum.
TABLE B.1
TYPICAL RANGER 305D (CE) FUEL CONSUMPTION
Kubota D722
Liters/Hr (Gal./Hr)
Running time for
45 Liters/hours
Low Idle - No Load
2200 R.P.M.
High Idle - No Load
3100 R.P.M.
DC Weld Output
250 Amps @ 30 Volts
DC Weld Output
225 Amps @ 25 Volts
.92 (.24)
1.62 (.43)
3.42 (.90)
2.92 (.77)
49.38
28.07
13.30
15.55
8,000 Watts, 3 PHASE
5,000 Watts, 3 PHASE
3,000 Watts, 3 PHASE
3.35 (.89)
2.65 (.70)
2.19 (.58)
13.54
17.12
20.78
RANGER 305D (CE)
B-5
WELDER OPERATION
DUTY CYCLE
Duty Cycle is the percentage of time the load is being applied in a 10 minute period. For example a 60% duty cycle, represents 6 minutes of load and 4 minutes of no load in a 10 minute period.
OPERATION
The RANGER 305D (CE) can be used with a broad range of DC stick electrodes. The MODE switch provides two stick welding settings as follows:
B-5
The OUTPUT CONTROL dial adjusts the full output range for stick welding. The ARC CONTROL dial sets the short circuit current (arc-force) during stick welding to adjust for a soft or a more forceful digging arc(crisp). Increasing the number from –10 (soft) to +10 (crisp) increases the short circuit current which results in a more forceful digging arc.
Typically a forceful digging arc is preferred for root and hot passes. A softer arc is preferred for fill and cap passes where weld puddle control and deposition ("stacking" of iron) are key to fast travel speeds. It is recommended that the ARC CONTROL be set initially at 0.
CONSTANT CURRENT (CC-STICK) Welding
The CC-STICK position of the MODE switch is designed for horizontal and vertical-up welding with all types of electrodes, especially low hydrogen.
The OUTPUT CONTROL dial adjusts the full output range for stick welding.
TIG WELDING
The TOUCH START TIG setting of the MODE switch is for
DC TIG (Tungsten Inert Gas) welding. To initiate a weld, the OUTPUT CONTROL dial is first set to the desired current and the tungsten is touched to the work. During the time the tungsten is touching the work there is very little voltage or current and, in general, no tungsten contamination. Then, the tungsten is gently lifted off the work in a rocking motion, which establishes the arc.
The ARC CONTROL dial sets the short circuit current (arcforce) during stick welding to adjust for a soft or crisp arc.
Increasing the dial from –10 (soft) to +10 (crisp) increases the short circuit current and prevents sticking of the electrode to the plate while welding. This can also increase spatter. It is recommended that the ARC CONTROL be set to the minimum number without electrode sticking. Start with a setting at 0.
To stop the arc, simply lift the TIG torch away from the work piece. When the arc voltage reaches approximately
30 volts, the arc will go out and the machine will automatically reset to the touch start current level. The tungsten may then be retouched to the work piece to restrike the arc. The arc may also be started and stopped with an
Amptrol or Arc Start Switch. See the following paragraphs.
DOWNHILL PIPE (STICK) Welding
The DOWNHILL PIPE position of the MODE switch is a slope controlled setting intended for "out-of-position" and
"down hill" pipe welding where the operator would like to control the current level by changing the arc length.
TABLE B.2
TYPICAL CURRENT RANGES
(1)
FOR TUNGSTEN ELECTRODES
(2)
TIG TORCH
Nozzle Size (4), (5)
1/16
3/32
1/8
5/32
3/16
1/4
Tungsten Electrode DCEN (-) DCEP (+) Approximate Argon Gas Flow
Diameter in. (mm) Flow Rate C.F.H. ( l /min.)
Stainless Steel 1%, 2% Thoriated 1%, 2% Thoriated Aluminum
Tungsten Tungsten
.010 (.25) 2-15
0.020
(.50) 5-20
0.040 (1.0) 15-80
(3)
(3)
(3)
3-8
5-10
5-10
(2-4)
(3-5)
(3-5)
3-8
5-10
5-10
(1.6) 70-150
(2.4) 150-250
(3.2) 250-400
(4.0) 400-500
(4.8) 500-750
(6.4) 750-1000
10-20
15-30
25-40
40-55
55-80
80-125
5-10
21-25
28-32
(3-5)
13-17 (6-8)
15-23 (7-11)
(10-12)
23-27 (11-13)
(13-15)
9-13
11-15
11-15
13-17
18-22
23-27
(2-4)
(3-5)
(3-5)
(4-6)
(5-7)
(5-7)
(6-8)
(8-10)
(11-13)
#4, #5, #6
#5, #6
#6, #7, #8
#8, #10
(1) When used with argon gas. The current ranges shown must be reduced when using argon/helium or pure helium shielding gases.
(2) Tungsten electrodes are classified as follows by the American Welding Society (AWS):
Pure EWP
1% Thoriated
2% Thoriated
EWTh-1
EWTh-2
Though not yet recognized by the AWS, Ceriated Tungsten is now widely accepted as a substitute for 2% Thoriated Tungsten in AC and DC applications.
(3) DCEP is not commonly used in these sizes.
(4) TIG torch nozzle "sizes" are in multiples of 1/16ths of an inch:
# 4 = 1/4 in.
# 5 = 5/16 in.
(6 mm)
(8 mm)
# 6 = 3/8 in.
# 7 = 7/16 in.
(10 mm)
(11 mm)
# 8 = _ in.
(12.5 mm)
#10 = 5/8 in.
(16 mm)
(5) TIG torch nozzles are typically made from alumina ceramic. Special applications may require lava nozzles, which are less prone to breakage, but cannot withstand high temperatures and high duty cycles.
RANGER 305D (CE)
B-6
OPERATION
When in the TOUCH START TIG mode and when a
Amptrol is connected to the 6-pin Connector the OUT-
PUT dial is used to set the maximum current range of the CURRENT CONTROL of the Amptrol.
B-6
For any electrodes the procedures should be kept within the rating of the machine. For additional electrode information see WWW.Lincolnelectric.com or the appropriate Lincoln publication.
The ARC CONTROL is not active in the TIG mode.
The RANGER 305D (CE) can be used in a wide variety of DC TIG welding applications. In general the ‘Touch
Start’ feature allows contamination free starting without the use of a Hi-frequency unit. If desired, the K930-2
TIG Module can be used with the RANGER 305D (CE).
The settings are for reference.
ARC GOUGING
The RANGER 305D (CE) can be used for limited arc gouging. For optimal performance, set the MODE switch to CC-STICK and the ARC CONTROL to +10.
Set the OUTPUT CONTROL knob to adjust output current to the desired level for the gouging electrode being used according to the ratings in the following
TABLE B.3
Table B.3.
RANGER 305D (CE) settings when using the K930-2
TIG Module with an Amptrol or Arc Start Switch:
• Set the MODE Switch to the TOUCH START TIG setting.
• Set the "IDLER" Switch to the "AUTO" position.
• Set the "WELDING TERMINALS" switch to the
"REMOTELY CONTROLLED" position. This will keep the "Solid State" contactor open and provide a “cold” electrode until the Amptrol or Arc Start Switch is pressed
When using the TIG Module, the OUTPUT control on the RANGER 305D (CE) is used to set the maximum range of the CURRENT CONTROL on the TIG module or an Amptrol if connected to the TIG Module. (See
Table B.2.)
WIRE WELDING-CV
Connect a wire feeder to the Ranger 305D according to the instructions in INSTALLATION INSTRUCTIONS
Section.
Carbon Diameter
1/8"
5/32"
3/16" positive)
AUXILIARY POWER:
Current Range (DC, electrode
60-90 Amps
90-150 Amps
200-250 Amps
Start the engine and set the IDLER control switch to the desired operating mode. Full power is available regardless of the welding control settings providing no welding current is being drawn.
Simultaneous Welding and Auxiliary Power Loads
The RANGER 305D (CE) in the CV-WIRE mode, permits it to be used with a broad range of flux cored wire
(Innershield and Outershield) electrodes and solid wires for MIG welding (gas metal arc welding). Welding can be finely tuned using the ARC CONTROL. Turning the
ARC CONTROL clockwise from –10 (soft) to +10 (crisp) changes the arc from soft and washed-in to crisp and narrow. It acts as an inductance/pinch control. The proper setting depends on the procedure and operator preference. Start with the dial set at 0.
While welding, the amount of 3-phase Auxiliary power available is reduced. (See table A.4)
WELDING OUTPUT-
AMPS
0
50
100
150
200
250
TABLE A.4
PERMISSIBLE POWER-WATTS
(UNITY POWER FACTOR)
PERMISSIBLE AUX
POWER @400V, 3PHASE
8000
6500
5000
3500
2000
0
RANGER 305D (CE)
12 Amps
9 Amps
7 Amps
5 Amps
3 Amps
0 Amps
C-1
ACCESSORIES
FIELD INSTALLED OPTIONS /
ACCESSORIES
K1898-1 SPARK ARRESTOR - Mounts between muffler & elbow to eliminate any risk of spark from exhaust.
K704 ACCESSORY SET - Includes (10m) 35 ft. of electrode cable and (9.m) 30 ft. of work cable, headshield, work clamp electrode holder. Cables are rated at 400 amps, 100% duty cycle.
K857 (7.6m) 25 ft. or K857-1 (30.4m) 100 ft.
REMOTE CONTROL - Portable control provides same dial range as the output control on the welder. Has a convenient 6 pin plug for easy connection to the welder.
C-1
RANGER 305D (CE)
D-1
SAFETY PRECAUTIONS
WARNING
MAINTENANCE
• Have qualified personnel do all maintenance and troubleshooting work.
• Turn the engine off before working inside the machine or servicing the engine.
• Remove guards only when necessary to perform maintenance and replace them when the maintenance requiring their removal is complete. If guards are missing from the machine, obtain replacements from a Lincoln
Distributor. (See Operating Manual Parts List.)
D-1
KUBOTA D722 DIESEL ENGINE
FREQUENCY
DAILY OR BEFORE
STARTING ENGINE
MAINTENANCE REQUIRED
• FILL FUEL TANK.
• CHECK OIL LEVEL.
• CHECK COOLANT LEVEL.
• CHECK AIR CLEANER ELE-
MENT AND HOUSING FOR
DIRTY, LOOSE OR DAMAGED
PARTS.
• CHECK AIR INTAKE HOSE
FOR CRACKS OR LOOSE
CONNECTIONS.
• CHECK AIR INTAKE/EXHAUST
AREAS & RADIATOR FOR
DIRT. CLEAN AS NECESSARY.
• CHECK ALTERNATOR BELT
TENSION AND WEAR.
• Read the Safety Precautions in the front of this manual and in the Engine Owner’s Manual before working on this machine.
Service Intervals
Observe the following for service and maintenance. The lubricating oil change intervals listed in the table below are for Classes CF,CE and CD lubricating oils of API classification with a low sulfur fuel in use. If the CF-4 or CG-4 lubricating oil is used with a high-sulfur fuel, change the lubricating oil at shorter intervals than recommended in the table below depending on the operating condition.
• Keep all equipment safety guards, covers, and devices in position and in good repair. Keep hands, hair, clothing, and tools away from the gears, fans, and all other moving parts when starting, operating, or repairing the equipment.
Routine Maintenance
At the end of each day’s use, refill the fuel tank to minimize moisture condensation in the tank. Running out of fuel tends to draw dirt into the fuel system.
Also, check the crankcase oil level and add oil if indicated.
ENGINE MAINTENANCE COMPONENTS
KUBOTA D722 DIESEL ENGINE
AIR FILTER ELEMENT DONALDSON P822686
FUEL FILTER ELEMENT KUBOTA 15231-43560
BELT
ITEM
OIL FILTER
BATTERY
MAKE AND PART NUMBER
KUBOTA 70000-15241
KUBOTA GROUP 58, 550 CCA
KUBOTA 15881-97011
GLOW PLUGS KUBOTA 16851-65512
INLINE FUEL FILTER KUBOTA 12581-43012
Intervals
Every 50 hours
Every 75 hours
Items
Check of fuel lines and clamp bands.
Change of engine oil •
Every 100 hours
Every 150 hours
Every 200 hours
Every 400 hours
Every 500 hours
Every 1 or 2 months
Every 800 hours
Every 1500 hours
Every 3000 hours
Every 2 years
Inspect/Clean air cleaner element and Vacuator™ valve.
Cleaning of fuel filter.
Check the battery electrolyte level.
Check the fan belt tightness.
Check the radiator and hose clamps.
Replacement of oil filter cartridge
Check the intake air lines.
Replacement of Air Filter element.
Replacement of fuel filter element.
Removal of of sediment in fuel tank.
Cleaning of water jacket (radiator interior).
Replacement of fan belt.
Recharging of Battery.
Check of valve clearance.
Check the fuel injection nozzle injection pressure.
Check of injection pump.
Check of fuel injector timer.
Replacement of battery
Replacement of radiator hoses and clamp band.
Replacement of fuel pipes and clamps.
Change the radiator coolant.(L.L.C.)
Replacement of intake air line.
*1
•
*1,*2
*3
*3
*3
*3
*4
IMPORTANT
•
These jobs should be done after the first 50 hours of operation.
*1 Air cleaner should be inspected/cleaned more often in dusty conditions than the normal conditions.
*2 Follow Service Instructions and Installation Tips for air cleaner in
Section D.
*3 Consult your local KUBOTA Dealer for this service.
*4 Replace only if necessary.
Please see Engine Owners Manual for Warranty Statement in detail.
RANGER 305D (CE)
D-2
MAINTENANCE
ENGINE OIL CHANGE
Drain the engine oil while the engine is warm to assure rapid and complete draining. It is recommended that each time the oil is changed the oil filter be changed as well.
• Be sure the unit is off. Disconnect the negative battery cable to ensure safety.
OIL FILTER CHANGE
• Drain the oil.
D-2
• Remove the oil filter with an oil filter wrench and drain the oil into a suitable container. Discard the used filter. Note: Care should be taken during filter removal to not disrupt or damage in any way the fuel lines.
• Locate oil drain hose and valve in bottom of base and pull through the hole in the battery access panel on the welder.
• Clean the filter mounting base and coat the gasket of the new filter with clean engine oil.
• Remove the cap from the drain valve. Push valve in and twist counterclockwise. Pull to open and drain the oil into a suitable container for disposal.
• Close the drain valve by pushing in and twisting clockwise. Replace the cap.
• Screw the new filter on by hand until the gasket contacts the mounting base. Using an oil filter wrench, tighten the filter an additional 1/2 to 7/8 of a turn.
• Refill the crankcase with the specified amount of the recommended engine oil. Reinstall the oil filler cap and tighten securely.
• Start the engine and check for oil filter leaks.
• Re-fill the crankcase to the upper limit mark on the dipstick with the recommended oil (see engine operation manual OR engine service items decal OR below). Replace and tighten the oil filler cap securely.
• Stop the engine and check the oil level. If necessary, add oil to the upper limit mark on the dipstick.
WARNING
• Push oil drain hose and valve back into unit, re-connect negative battery cable, and close doors and engine top cover before restarting unit.Wash your hands with soap and water after handling used motor oil. Please dispose of used motor oil in a manner that is compatible with the environment.
We suggest you take it in a sealed container to your local service station or recycling center for reclamation. DO NOT throw it in the trash; pour it on the ground or down a drain.
• Never use gasoline or low flash point solvents for cleaning the air cleaner element. A fire or explosion could result.
CAUTION
ENGINE OIL REFILL CAPACITIES
Without oil filter replacement:
• 3.2 liter (3.3 U.S. Quart)
• Never run the engine without the air cleaner.
Rapid engine wear will result from contaminants, such as dust and dirt being drawn into the engine.
------------------------------------------------------------------------
AIR CLEANER
With oil filter replacement:
• 3.2 liter ( 3.4 U.S. Quart.) The diesel engine is equipped with a dry type air filter.
Never apply oil to it. Service the air cleaner as follows:
Use motor oil designed for diesel engines that meets requirements for API service classification
CC/CD/CE/CF/CF-4/CG-4 or CH-4.
ACEA E1/E2/E3. Always check the API service label on the oil container to be sure it includes the letters indicated. (Note: An S-grade oil must not be used in a diesel engine or damage may result. It IS permissible to use an oil that meets S and C grade service classifications.)
SAE 10W30 is recommended for general, all temperature use, -15C to 40C (5F to 104F).
See engine owner’s manual for more specific information on oil viscosity recommendations.
Replace the element at least every 200 hours of operation and sooner under dusty conditions.
RANGER 305D (CE)
D-3 D-3
MAINTENANCE
Service Instructions & Installation Tips
For Engine Air Filter
1
Release the
Seal Carefully
Unlatch and remove the service cover of the air cleaner. Make certain the latches are folded back against the cover so that they donít hinder filter removal/installation. Most latches are spring loaded to fold back when open.
The filter fits tightly over the outlet tube, creating the critical seal on the inside diameter of the filter endcap. The filter should be removed gently to reduce the amount of dust dislodged. There will be some initial resistance, similar to breaking the seal on a jar. Gently move the end of the filter back and forth to break the seal.
Avoid Dislodging
2
Dust from the Filter
Gently pull the filter off the outlet tube and out of the housing. Avoid knocking the filter against the housing.
Clean Sealing Surface
3
of the Outlet Tube
Use a clean cloth to wipe the sealing surface. Dust on the outside diameter of the outlet tube could hinder an effective seal and cause leakage.
Make sure that all contaminant is removed before the new filter is inserted.
Check the Old
5
Filter for Leak Clues
Visually inspect the old filter for any signs of leaks. A streak of dust on the clean side of the filter is a telltale sign.
Remove any cause of leaks before installing new filter.
Donaldson filters with RadialSeal
™ Sealing
Technology are self-aligning, self-centering, and self-sealing. A new filter has a dry lubricant to aid installation. The critical sealing area will stretch slightly, adjust itself and distribute the sealing pressure evenly. To complete a tight seal, apply pressure by hand at the outer rim of the filter, not the flexible center. (Avoid pushing on the center of the urethane end cap.) No cover pressure is required to hold the seal. Again, do NOT use the service cover to push the filter into place!
Inspect the New
6
Filter for Damage
Inspect the new filter carefully, paying attention to the inside of the open end, which is the sealing area.
NEVER install a damaged filter.
When the filter in is place, put the service cover back on, making sure the Vacuator ™
Valve points down. Inspect the Vacuator ™
Valve for cracks or dust hang-ups to insure that it is functioning properly. Re-fasten the latches.
Insert the New
7
RadialSeal
ô
Filter by Hand
Insert carefully. Seat the new filter by hand, making certain it is completely into the air cleaner housing before latching the cover in place. If the cover hits the filter before it is fully in place, remove the cover and push
(by hand) the filter further into the air cleaner and try again.
The cover should go on with no extra force.
Check Connections
8
for Tight Fit
Make sure that all clamps, bolts, and connections in the entire air intake system are tight. Check for holes in piping, and repair if needed.
Clean the Inside of
4
the Outlet Tube
Carefully wipe the inside of the outlet tube with a clean cloth.
Dirt accidently transferred to the inside of the outlet tube will reach the engine and cause wear.
(Engine manufacturers says that it takes only a few grams of dirt to ëdustí an engine!) Be careful not to damage the sealing area on the tube.
Never use the latches on the cover to force the filter into the air cleaner! It is tempting to assume the cover will do the job of seating the filter ñ but it will not! Using the latches to push the filter in could cause damage to the housing and will void the warranty.
RANGER 305D (CE)
D-4
COOLING SYSTEM
WARNING
MAINTENANCE
HOT COOLANT
can burn skin.
FUEL
D-4
At the end of each day’s use, refill the fuel tank to minimize moisture condensation and dirt contamination in the fuel line. Do not overfill; leave room for the fuel to expand.
• Do not remove cap if radiator is hot.
Use only fresh, No. 2 grade DIESEL fuel. Do not use kerosene.
------------------------------------------------------------------------
Check the coolant level by observing the level in the radiator and recovery bottle. Add 50/50 antifreeze / water solution if the level is close to or below the
"LOW" mark. do not fill above the "FULL" mark.
Remove radiator cap and add coolant to radiator. Fill up to the top of the tube in the radiator filler neck which includes a connecting hose coming from the thermostat housing.
To drain the coolant, open the valve of the radiator.
Open the radiator cap to allow complete drainage.
(Tighten the valve and refill with a 50/50 antifreeze/water solution.) Use an automotive grade
(low silicate) ethylene glycol antifreeze. The cooling system capacity is 3.6L (3.85 quarts). Squeeze upper and lower radiator hoses while filling to bleed air from system coolant. Replace and tighten the radiator cap.
See the Engine Operator's Manual for instructions on replacing the fuel filter.
BLEEDING THE FUEL SYSTEM
You may need to bleed air from the fuel system if the fuel filter or fuel lines have been detached, the fuel tank has been ran empty or after periods of long storage. It is recommended that the fuel shutoff valve be closed during periods of non-use.
(For Codes 11122, 11123)
The Kubota D722 engine supplied with this welder is equipped with an automatic bleeding mechanism that functions when the electric fuel pump is actuated. It is generally not necessary to open a vent screw or fuel line fitting to bleed the fuel system.
CAUTION
Always premix the antifreeze and clean tap water before adding to the radiator. It is very important that a precise 50/50 solution be used with this engine year round. This gives proper cooling during hot weather and freezing protection to -37° C
(-34° F).
(For Codes 11189, 11190)
The Kubota D722 engine supplied with this welder is equipped with an automatic bleeding mechanism that helps purge the air from the mechanical fuel pump system. It is generally not necessary to open a vent screw or fuel line fitting to bleed the fuel system.
Operate the priming lever on the pump to assist starting after extended periods of non-use or out of fuel conditions.
WARNING
Cooling solution exceeding 50% ethylene glycol can result in engine overheating and damage to the engine. Coolant solution must be premixed before adding to radiator.
------------------------------------------------------------------------
To avoid personal injury, do not bleed a hot engine. This could cause fuel to spill onto a hot exhaust manifold, creating a danger of fire.
------------------------------------------------------------------------
Bleed the fuel system as follows:
Periodically remove the dirt from the radiator fins.
Periodically check the fan belt and radiator hoses.
Replace if signs of deterioration are found.
TIGHTENING THE FAN BELT
If the fan belt is loose, the engine can overheat and the battery lose its charge. Check tightness by pressing on the belt midway between the pulleys. It should deflect about 6mm (.25 in) under a load of 9 Kg (20 lbs).
1. Fill the fuel tank with fuel.
2. Open the fuel shut off valve (vertical position of handle) on the Fuel Filter.
3. Press and hold the glow plug button for 10 to 20 seconds.(For Codes 11122, 11123)
3a. Crank the engine by pressing the start button for
45 seconds. (For Codes 11189, 11190)
4. Check to see that fuel is flowing through both fuel filters.
5. Follow the normal STARTING procedures.
RANGER 305D (CE)
D-5
MAINTENANCE
FUEL FILTER
1. Check the fuel filter and fuel pre-filter for water accumulation or sediment.
2. Replace the fuel filter if it is found with excessive water accumulation or sediment. Empty fuel pre-filter.
OVERSPEED IS HAZARDOUS
The maximum allowable high idle speed for this machine is 3150 RPM, no load. Do NOT tamper with governor components or setting or make any other adjustments to increase the maximum speed. Severe personal injury and damage to the machine can result if operated at speeds above maximum.
CHECKING THE ELECTROLYTE LEVEL
D-5
CLEANING THE BATTERY
Keep the battery clean by wiping it with a damp cloth when dirty. If the terminals appear corroded, disconnect the battery cables and wash the terminals with an ammonia solution or a solution of 113g (1/4 pound) of baking soda and 0.9461L (1 quart) of water. Be sure the battery vent plugs (if equipped) are tight so that none of the solution enters the cells.
After cleaning, flush the outside of the battery, the battery compartment, and surrounding areas with clear water. Coat the battery terminals lightly with petroleum jelly or a non-conductive grease to retard corrosion.
Keep the battery clean and dry. Moisture accumulation on the battery can lead to more rapid discharge and early battery failure.
ENGINE ADJUSTMENT
Adjustments to the engine are to be made only by a
Lincoln Service Center or an authorized Field Service
Shop.
If battery cells are low, fill them to the neck of the filler hole with distilled water and recharge. If one cell is low, check for leaks.
BATTERY MAINTENANCE
To access the battery, Disconnect the Negative and then Positive battery cables. Remove the 4 screws from the battery door using a screwdriver or a 10mm socket. Remove the 2 nuts from the battery bracket using a 11mm wrench or socket. Slide the battery out and remove from welder
WARNING
GASES FROM BATTERY can explode.
● Keep sparks, flame and cigarettes away from battery.
To prevent EXPLOSION when:
● INSTALLING A NEW BATTERY — disconnect negative cable from old battery first and connect to new battery last.
● CONNECTING A BATTERY CHARGER — remove battery from welder by disconnecting negative cable first, then positive cable and battery clamp. When reinstalling, connect negative cable last. Keep well ventilated.
●
●
USING A BOOSTER — connect positive lead to battery first then connect negative lead to negative battery lead at engine foot.
BATTERY ACID can burn eyes and skin.
● Wear gloves and eye protection and be careful when working near battery.
Follow instructions printed on battery.
CHARGING THE BATTERY
When you charge, jump, replace, or otherwise connect battery cables to the battery, be sure the polarity is correct. Improper polarity can damage the charging circuit. The RANGER 305D (CE) positive (+) battery terminal has a red terminal cover.
If you need to charge the battery with an external charger, disconnect the negative cable first, then the positive cable before you attach the charger leads.
After the battery is charged, reconnect the positive battery cable first and the negative cable last. Failure to do so can result in damage to the internal charger components.
Follow the instructions of the battery charger manufacturer for proper charger settings and charging time.
SERVICING OPTIONAL SPARK
ARRESTOR
Clean every 100 hours.
WARNING
• MUFFLER MAY BE HOT
• ALLOW ENGINE TO COOL BEFORE INSTALLING
THE SPARK ARRESTER!
• DO NOT OPERATE ENGINE WHILE INSTALLING
THE SPARK ARRESTER!
RANGER 305D (CE)
D-6
WELDER / GENERATOR
MAINTENANCE
MAINTENANCE
STORAGE: Store the RANGER 305D (CE) in clean, dry protected areas.
CLEANING: Blow out the generator and controls periodically with low pressure air. Do this at least once a week in particularly dirty areas.
BRUSH REMOVAL AND REPLACEMENT: It’s normal for the brushes and slip rings to wear and darken slightly. Inspect the brushes when a generator overhaul is necessary.
CAUTION
• Do not attempt to polish slip rings while the engine is running.
WARNING
• Service and Repair should only be performed by
Lincoln Electric Factory Trained Personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician and machine operator and will invalidate your factory warranty. For your safety and to avoid Electrical
Shock, please observe all safety notes and precautions.
D-6
RANGER 305D (CE)
E-1
TROUBLESHOOTING
HOW TO USE TROUBLESHOOTING GUIDE
E-1
WARNING
Service and Repair should only be performed by Lincoln Electric Factory Trained Personnel.
Unauthorized repairs performed on this equipment may result in danger to the technician and machine operator and will invalidate your factory warranty. For your safety and to avoid Electrical
Shock, please observe all safety notes and precautions detailed throughout this manual.
__________________________________________________________________________
This Troubleshooting Guide is provided to help you locate and repair possible machine malfunctions.
Simply follow the three-step procedure listed below.
Step 3. RECOMMENDED COURSE OF ACTION
This column provides a course of action for the
Possible Cause, generally it states to contact your local Lincoln Authorized Field Service Facility.
Step 1. LOCATE PROBLEM (SYMPTOM).
Look under the column labeled “PROBLEM (SYMP-
TOMS)”. This column describes possible symptoms that the machine may exhibit. Find the listing that best describes the symptom that the machine is exhibiting.
If you do not understand or are unable to perform the
Recommended Course of Action safely, contact your local Lincoln Authorized Field Service Facility.
Step 2. POSSIBLE CAUSE.
The second column labeled “POSSIBLE CAUSE” lists the obvious external possibilities that may contribute to the machine symptom.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
RANGER 305D (CE)
E-2
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
E-2
Major Physical or Electrical Damage is Evident.
1. Contact your local Lincoln
Authorized Field Service
Facility.
Engine will not "crank".
Engine will "crank" but not start.
Engine shuts down shortly after starting.
1. Battery is low, Charge Battery.
2. Loose battery cable connections.
Inspect, clean and tighten terminals.
3. Faulty engine starter motor.
Contact authorized local Engine
Service Shop.
1. Fuel shut off valve on Main Fuel
Filter in the OFF position. Open valve (vertical) position of handle.
2. Fuel Filters dirty/clogged. Check and replace main filter element and/or Inline Fuel Filter.
3. Out of fuel. Fill tank and bleed fuel system.
4. High coolant temperature or low oil pressure. (indictor lights lit)
Check oil and coolant levels. Fill if required. Check for loose or broken fan belt.
5. Faulty fuel shutdown solenoid.
Check that shutdown solenoid is functioning properly and not binding/ contact authorized engine service shop.
6. Faulty fuel pump. Check for fuel flow through filters. Contact authorized local Engine Service
Shop.
If all recommended possible areas of misadjustment have been checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.
1. High coolant temperature or low oil pressure. (indictor light lit)
Change oil and oil filters and fill to proper level. Check and fill coolant level. Check for loose or broken fan belt. Start engine and look for leaks.
2. Faulty oil pressure switch or other engine component. Contact authorized local Engine Service
Shop.
3. Faulty engine protection relay.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
RANGER 305D (CE)
E-3
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
E-3
Engine shuts down while under a load.
1. High radiator coolant temperature. Reduce load if it is exceeding machine rating. Add coolant to system if low. Clean fins on radiator if dirty. Tighten fan belt if loose. Remove objects blocking or close to intake openings on both sides of base and exhaust end (case back).
Engine runs rough.
1. Dirty fuel or air filters. Inspect and clean/replace filters as needed.
Inspect and clean/replace filters as needed.
2. Water in fuel. If water found in tank. Empty fuel tank and refill then purge fuel lines.
Battery does not stay charged.
Engine will not idle down to low speed.
1. Faulty battery. Replace.
2. Loose connections at battery or alternator. Clean and tighten connections.
3. Faulty engine alternator or charger module. Consult authorized
Engine Service Shop.
If all recommended possible areas of misadjustment have been checked and the problem persists, Contact your local Lincoln Authorized
Field Service Facility.
1. Idler switch in High idle position.
Set switch to Auto.
2. External load on welder or auxiliary power. Remove all external loads.
3. Faulty PC board or idler solenoid.
Engine will not go to high idle when attempting to weld.
1. Poor work lead connection to work. Make sure work clamp is tightly connected to clean base metal.
2. "Contactor" switch is in wrong position. Set to "Welding On" when welding without a control cable.
Refer to Operations chapter for proper use of this switch.
3. Faulty PC board. Low idle speed set to low.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
RANGER 305D (CE)
E-4
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
E-4
Engine will not go to high idle when using auxiliary power.
1. Auxiliary power load is less than
100 watts. Idler may not respond with less than a 100 watt load. Set idler to "High".
2. Faulty PC board.
Engine will not go to high idle under weld or auxiliary loading.
1. Faulty idler solenoid. Check for bent linkage or broken spring
Engine does not develop full power. Engine runs rough.
1. Fuel filter clogged, Replace.
2. Air filter clogged, clean or replace.
3. High idle setting incorrect, check and adjust if required.
4. Valves out of adjustment.
5. Fuel contaminated with water or sediment. Check fuel pre-filter and empty of water, bleed fuel system. Replace fuel in tank if needed.
Engine will not go to high idle when attempting to weld or using auxiliary power. Switching to manual high idle does not work.
Engine will not shut off.
1. Broken spring on Idle Solenoid, solenoid linkage binding, Faulty
PC board, low idle speed set too low on idle solenoid.
1. Fuel Shutdown solenoid not functioning properly / linkage binding. Stop engine by shutting off valve located on main fuel filter. Contact authorized local
Engine Service Shop.
If all recommended possible areas of misadjustment have been checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.
Engine does not develop full power.
Low weld and auxiliary output.
Engine runs rough.
1. Fuel filter dirty/clogged. Replace.
2. Air filter dirty/clogged. Replace
Air Filter Element.
3. Fouled fuel injector(s). Contact authorized Engine Service Shop.
4. Fuel contaminated with water.
Check Main Filter Bowl and Inline
Fuel filters for water. Clean and replace as needed. Replace fuel in tank.
5. Cracked or loose fuel hose.
Replace hose and tighten clamps.
6. Valves out of adjustment. Contact authorized local Engine Service
Shop.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
RANGER 305D (CE)
E-5
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
E-5
No welding power output.
Auxiliary Power OK.
1. Poor work lead connection to work. Make sure work clamp is tightly connected to clean base metal.
2. "Weld Terminals" switch in wrong position. Place switch in "Weld
Terminals On" position when welding without control cable.
3. Faulty PC board.
Welder has output but no control.
Wire feeder does not work when control cable is connected to 14 pin connector.
1. Wire Feeder Power circuit breaker open. Check 42V beaker and reset if tripped.
2. Faulty control cable. Repair or replace cable.
3. Faulty wire feeder. Replace wire feeder.
If all recommended possible areas of misadjustment have been checked and the problem persists,
Contact your local Lincoln
Authorized Field Service Facility.
No auxiliary power.
1. Poor remote/control cable connection to 6-pin or 14-pin connector.
Check connections.
2. Faulty remote cable or faulty wire feeder or wire feeder cable.
Replace if necessary.
3. Faulty control potentiometer or PC board.
1. Open circuit breakers. Reset breakers. If breakers keep tripping, reduce power draw.
2. Faulty connections to auxiliary receptacles. Check connections.
3. RCD tripped. Clear any ground fault and reset RCD circuit by pressing "Reset" button.
4. Faulty PC board or welder alternator.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
RANGER 305D (CE)
E-6
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
PROBLEMS
(SYMPTOMS)
POSSIBLE
CAUSE
RECOMMENDED
COURSE OF ACTION
E-6
The welding arc is “cold.” The welding arc is not stable or is not satisfactory. the engine runs normally.
The auxiliary power is normal.
1. Make sure the MODE selector switch is in the correct position for the process being used. (For example, CV-WIRE, PIPE, CC-STICK.)
2. Make sure the electrode (wire, gas, voltage, current etc.) is correct for the process being used.
3. Check for loose or faulty connections at the weld output terminals and welding cable connections.
4. The welding cables may be too long or coiled, causing an excessive voltage drop.
If all recommended possible areas of misadjustment have been checked and the problem persists, Contact your local Lincoln Authorized
Field Service Facility.
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
RANGER 305D (CE)
F-1
DIAGRAMS
F-1
RANGER 305D (CE)
F-2
DIAGRAMS
F-2
RANGER 305D (CE)
F-3
DIAGRAMS
F-3
RANGER 305D (CE)
F-4
DIAGRAMS
F-4
RANGER 305D (CE)
F-5
DIAGRAMS
F-5
RANGER 305D (CE)
F-6
DIAGRAMS Enhanced Diagram
F-6
RANGER 305D (CE)
F-7
1
2
DIAGRAMS
10 10
5 5 5 5 5 5 5 5 5 5 5 5 1 1 1 1 1 1 1 1 1 1 1 1
6 6
5 5 5 5 5 5 5 5
10
1 1 1 1 1 1 1 1 1 1 1 1
6
8
16
1
9
6
12
1
7
8
16
1
9
8
16 9
1
Enhanced Diagram
F-7
M4
M5
M6
M9
M10
M2
M1
M3
M4
M3
M5
M2
M1
M6
M9
M10
SHOWN IN "AUTO" POSITION
S2 ST
B7 B8
300 AMP MODULE
EXCITATION WINDING
C3 800uf 150vdc
S7 GLOW PL
GND SCREW ON FAN B
H2O TEM
OIL PRE
RCDI 30
CONTACTOR CONTROL SHOWN IN "WELDING ON
RANGER 305D (CE)
F-8
DIAGRAMS Enhanced Diagram
F-8
RANGER 305D (CE)
F-9
1
2
DIAGRAMS
10 10
5 5 5 5 5 5 5 5 5 5 5 5 1 1 1 1 1 1 1 1 1 1 1 1
6 6
5 5 5 5 5 5 5 5
10
1 1 1 1 1 1 1 1 1 1 1 1
6
8
16
1
9
6
12
1
7
8
16
1
9
8
16 9
1
Enhanced Diagram
F-9
M4
M3
M5
M2
M1
M6
M9
M10
M4
M5
M6
M9
M10
M2
M1
M3
SHOWN IN "AUTO" POSITION
S2 ST
B7 B8
300 AMP MODULE
EXCITATION WINDING
C3 800uf 150vdc
S7 GLOW PL
GND SCREW ON FAN B
H2O TEM
OIL PRE
RCDI 30
CONTACTOR CONTROL SHOWN IN "WELDING ON
RANGER 305D (CE)
F-10
6.33 16
DIMENSION PRINT
F-10
RANGER 305D (CE)
NOTES
RANGER 305D (CE)
NOTES
RANGER 305D (CE)
NOTES
RANGER 305D (CE)
Chinese
Korean
Arabic
WARNING
Spanish
AVISO DE
PRECAUCION
French
ATTENTION
German
WARNUNG
Portuguese
ATENÇÃO
●
●
Do not touch electrically live parts or electrode with skin or wet clothing.
Insulate yourself from work and ground.
●
●
No toque las partes o los electrodos bajo carga con la piel o ropa mojada.
Aislese del trabajo y de la tierra.
● Keep flammable materials away.
● Mantenga el material combustible fuera del área de trabajo.
●
●
Wear eye, ear and body protection.
Protéjase los ojos, los oídos y el cuerpo.
●
●
Ne laissez ni la peau ni des vêtements mouillés entrer en contact avec des pièces sous tension.
Isolez-vous du travail et de la terre.
● Gardez à l’écart de tout matériel inflammable.
● Protégez vos yeux, vos oreilles et votre corps.
●
●
Berühren Sie keine stromführenden
Teile oder Elektroden mit Ihrem
Körper oder feuchter Kleidung!
Isolieren Sie sich von den
Elektroden und dem Erdboden!
●
●
Não toque partes elétricas e electrodos com a pele ou roupa molhada.
Isole-se da peça e terra.
● Entfernen Sie brennbarres Material!
● Tragen Sie Augen-, Ohren- und Körperschutz!
● Mantenha inflamáveis bem guardados.
● Use proteção para a vista, ouvido e corpo.
Japanese
READ AND UNDERSTAND THE MANUFACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE
USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL FABRICANTE PARA EL USO DE ESTE EQUIPO Y LOS
CONSUMIBLES QUE VA A UTILIZAR, SIGA LAS MEDIDAS DE SEGURIDAD DE SU SUPERVISOR.
LISEZ ET COMPRENEZ LES INSTRUCTIONS DU FABRICANT EN CE QUI REGARDE CET EQUIPMENT ET LES PRODUITS A
ETRE EMPLOYES ET SUIVEZ LES PROCEDURES DE SECURITE DE VOTRE EMPLOYEUR.
LESEN SIE UND BEFOLGEN SIE DIE BETRIEBSANLEITUNG DER ANLAGE UND DEN ELEKTRODENEINSATZ DES HER-
STELLERS. DIE UNFALLVERHÜTUNGSVORSCHRIFTEN DES ARBEITGEBERS SIND EBENFALLS ZU BEACHTEN.
●
●
Keep your head out of fumes.
Use ventilation or exhaust to remove fumes from breathing zone.
● Turn power off before servicing.
● Do not operate with panel open or guards off.
WARNING
●
●
Los humos fuera de la zona de respiración.
Mantenga la cabeza fuera de los humos. Utilice ventilación o aspiración para gases.
●
●
Gardez la tête à l’écart des fumées.
Utilisez un ventilateur ou un aspirateur pour ôter les fumées des zones de travail.
● Desconectar el cable de alimentación de poder de la máquina antes de iniciar cualquier servicio.
● Débranchez le courant avant l’entretien.
● No operar con panel abierto o guardas quitadas.
● N’opérez pas avec les panneaux ouverts ou avec les dispositifs de protection enlevés.
●
●
Vermeiden Sie das Einatmen von
Schweibrauch!
Sorgen Sie für gute Be- und
Entlüftung des Arbeitsplatzes!
● Strom vor Wartungsarbeiten abschalten! (Netzstrom völlig öffnen; Maschine anhalten!)
● Anlage nie ohne Schutzgehäuse oder Innenschutzverkleidung in
Betrieb setzen!
●
●
Mantenha seu rosto da fumaça.
Use ventilação e exhaustão para remover fumo da zona respiratória.
●
●
●
Não opere com as tampas removidas.
Desligue a corrente antes de fazer serviço.
Não toque as partes elétricas nuas.
●
●
Mantenha-se afastado das partes moventes.
Não opere com os paineis abertos ou guardas removidas.
Spanish
AVISO DE
PRECAUCION
French
ATTENTION
German
WARNUNG
Portuguese
ATENÇÃO
Japanese
Chinese
Korean
Arabic
LEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE PARA ESTE EQUIPAMENTO E AS PARTES DE USO, E SIGA AS
PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• World's Leader in Welding and Cutting Products •
• Sales and Service through Subsidiaries and Distributors Worldwide •
Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com
advertisement