Omega OS540 User's Manual

Add to my manuals
2 Pages

advertisement

Omega OS540 User's Manual | Manualzz

Mini Infrared Thermomete

2

4 -

Laser Warning

Label

??

Precise non-contact temperature measurements

??

Switchable “WF temperature units

??

Automatic data hold

??

Laser target pointer switchable between laser dot and circle

1. SAFETY

Use extreme caution when the laser beam is turned On.

!

Do not let the beam enter your eye, another person ’s eye or the eye of an animal.

!

Be careful not to let the beam on a reflective surface strike your eye.

!

Do not operate the laser light beam il presence of any gas which can explode.

2. GENERAL SPECIFICATIONS

Sample rate

Power Supply

Power Current

Weight

1 sec. approx.

Power off

Operating remperature

Automatic shutoff al

5 seconds

0°C to 50°C

(32°F to 122°F)

Operating Humidity Max. 80% RH.

9V battery

Approx. 12mA DC

Size

12Ogl6.4oz.

16.7x1.7x1.6

(170 x 44 x 40mm)

LASER SIGHT r

Wave length(color)

Operating Distance

Output Optical Power

Beam Diameter

Beam Divergence

Power Indicator

675nm (red)

Up to 30Ft.Max

<I mW, Class II

Laser Product

-

-

LCD icon

D

D:S=8:1

D(Distance)

112 400

S

$14

$50

800

$100 mm

mm

RANGE SPECIFICATIONS

Resolution/ 1 “C/F -4 to 788°F

Ranges (-20 to 420°C)

Accuracy

+2% of reading (-20-l or

OO’C)

*2”C whichever is greater.

IOl -420°C *3% of reading or +3X whichever is greater.

Accuracy notes

1. Accuracy specified is for temperature.

2. Accuracy specified is for emissivity of 0.95.

0.95 fixed Emissivity settings

Distance

Factor

D/S

(D

= Approx. 8:l

= distance, S = Spot)

3. NON-CONTACT

OPERATION

Il? MEASUREMENT a. Power ON/OFF

The meter automatically powers when the

Measure key is pressed. Press the

Measure key to take a reading. Read the measured temperature on the LCD. The meter powers OFF automatically approximately 5 seconds after the

Measure key is released.

b. Selecting Temperature units (C/F)

Select temperature units (degrees C or F) by first pressing the Measure key and then pressing the C/F key. The units will blink on the LCD. Press the C/F key until the desired units are shown on the LCD.

c. Data Hold

This meter automatically holds the last temperature reading on the LCD for five seconds after the Measure key is released. No extra key presses are necessary to freeze the displayed reading.

FRONT PANEL DESCRIPTION

1. Laser pointer beam 9. Laser Dot/Circle

2. IR sensor

3. LCD Display

4. C/F select key

Switch

10. Laser Dot/Circle

Label

5. Backlight select key 11. Laser Warning

6. Measure key Label

7. Laser key 12. Field of View Label

6. Battery compartment d. Backlight LCD

Select backlight by first pressing the

Measure key and then pressing the

BACKLIGHT key. Repeat the procedure to turn the backlight OFF e. Laser Pointer

To turn the laser pointer ON, press the

LASER key while pressing the Measure key. Repeat the procedure to turn the laser

OFF. While the laser is on, you can switch between laser dot and circle by moving a lever in front of the optics. Laser dot is an indication of the center of the field of view.

Laser circle in an indication of the perimeter of the field of view.

f. Measurement Considerations

Holding the meter by its handle, point the IR

Sensor toward the object whose temperature is to be measured. The meter automatically compensates for temperature deviations from ambient temperature. Keep in mind that it will take up to 30 minutes to adjust to wide ambient temperature changes. When low temperatures are to be measured followed by high temperature measurements, some time (several minutes) is required after the low (and before the high) temperature measurements are made.

This is a result of the cooling process which must take place for the I R sensor

4. BATTERY REPLACEMENT

A flashing display is the indication that the battery voltage has fallen into the critical region (6.5 to 7.5 V). Reliable readings can be obtained for several hours after the first appearance of the low battery indication.

Open the Battery Compartment and remove the battery then install a new battery and replace the cover.

OMEGAneP Online Service www.omega.com

Internet e-mail [email protected]

USA:

IS0 9001 Certified

Servicing North Amtwica:

One Omega

Drive, Box 4047

Stamford CT 06907-0047

Tel: (203) 359-1660 e-mail: [email protected]

FAX: (203) 359-7700

Canada:

976 Bergar

Lava1 (Quebec) H7L 5Al

Tel: (514) 856-6928 e-mail: infoQomega.ca

For immediate technical or appl

USA and Canada:

Sales Service: l-800-826-6342

Customer Service: l-800-622-23:

Engineering Service: l-800-872-1

TELEX: 996404 EASYLINK: 62

/ 1

FAX: (514) 856-6886

:ation assistance:

300.TC-OMECAO

/

36

I-800.622.BEST=

/ l-SOII-USA-WHEN”

18934 CABLE: OMEGA

Mexico:

En Espaiiol: (001)

FAX: (001)

203-359-7803

203-359-7807 e-maiI:[email protected]

[email protected]

Benelux:

Servicing Europe:

Postbus 8034,118O LA

Tel: +31 (0)20 3472121

Amstelveen, The Netherlands

Toll Free in Benelux: 0800 0993344 e-mail: nlQomega.com

FAX: +31 (0)20 6434643

Czech Republic: Rude armBdy 1868,733 01

Tel: +420 (0)69 6311899

Toll Free: 0800-l-66342

Karvind 8

FAX: e-mail:

+420 (0)69 6311114 [email protected]

France: 9, rue

Tel:

Denis

+33

Papin, 78190

(0)130 621 400

Toll Free in France: 0800-4-06342 e-mail: [email protected]

Trappes

FAX: +33 (0)130 699 120

Germany/Austria: Daimlerstrasse 26, D-75392

Tel: +49 (0)7059 9398-O

Toll Free in Germany: 0800 639 7678 e-mail: [email protected]

Deckenpfronn, Germany

FAX: +49 (0)7056 9398-29

United Kingdom:

Is0 9002 c&if&

One

Omega Drive, River Bend Technology Centre

Northbank, Warn, Manchester

M44 5EX United Kingdom

Tel: +44 (0)161 777 6611

Toll Free in United Kingdom: e-mail: salesOomega.co.uk

FAX:

0800-488-488

+44 (0)161 777 6622 ducts are not designed for use in, and should not be used for, patient-connected applications.

from date of purchase. OMEGA product warranty to cover coverage on each product.

ing and shipping time. This ensures that OMEGA ’s customers receive maximum

If the unit malfunctions, it must

Authorized Return (AR) numbe found to be defective, it will be from any action of the purchase ed to the factory for evaluation. OMEGA ’s Customer Service Department will iately upon phone or written request. Upon examination by OMEGA, if the unit is ired or replaced at no charge. OMEGA ’s WARRANTY does not apply to defects resulting eluding but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or unau rized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows eviden of having been damaged as a result of excessive corrosion; or current, heat, moisture or vibration; improper specificati ; misapplication; misuse or other operating conditions outside of OMEGA ’s control.

Components which wear are not rranted, including but not limited to contact points, fuses, and triacs.

OMEGA is pleased to offer responsibility for any omiss products in accordance with the parts manufactured by it I estions on the use of its various products. However, OMEGA neither assumes errors nor assumes liability for any damages that result from the use of its ation provided by OMEGA, either verbal or written. OMEGA warrants only that be as specified and free of defects. OMEGA MAKES NO OTHER

D WHATSOEVER, EXPRESS OR IMPLIED, EXCEPT THAT OF TITLE, AND AU

NTY OF

OF

MERCHANTABILD-Y AND FDIUESS FOR A

WARRANDES OR

IMPUED

PARTlCULAR PURPOSE

LlABILlTYz The remediis of purchaser set forth herein are exclusive, and respect to this order, whether based on contract, warranty, negligence, herwise, shall not exceed the purchase price of the component upon which

EGA be liable for consequential, incidental or special damages.

CONDITIONS: Equipment sol

10 CFR 21 (NRC), used in or wi any Product(s) be used in or

OMEGA is not intended to be used, nor shall it be used: ny nuclear installation or activity; or (2)

(1) as a “Basic Component” under in medical applications or used on humans. Should wrt ny nuclear installation or activity, medical application, used on humans, or misused in any way, OMEGA assumes purchaser will indemnify of the Product(s) in such and hold OMEGA harmless from any liability or damage whatsoever arising out of the use

RETURN

REQUESTS / [NQUlRlES

‘* +l, i, ;‘:,i.‘,. .‘*I: : ‘;‘“‘;.’ i!.:,

Direct all warranty and

PRODUCT(S) TO OME

CUSTOMER SERVICE D nquiries to the OMEGA Customer Service Department. BEFORE RETURNING ANY

R MUST OBTAIN AN AUTHORIZED RETURN (AR) NUMBER FROM OMEGA ’S

ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then

FOR

WARRANTY RETUR information available BEF

1. Purchase Order numbe

PURCHASED,

2. Model and serial number o warranty, and

3. Repair instructions and/or the product.

PATENT NOTICE:

U.S.

OMEGA ’s policy is to make technology and engineering.

PAT.

Bl 5, runn

OMEGA is a registered trademark of

0 Copyright 2000 OMEGA ENGINEER1 to any electronic medium or machine-r fit problems relative to

FOR

NON-WARRANTY REPAIRS, consult OMEGA for current repair charges. Have the following information available BEFORE contacting OMEGA:

1. Purchase Order number to cover the COST of the repair,

2. Model and serial number of the product, and

3. Repair instructions and/or specific problems relative to the product.

4,984; 5.727.880, 5.465.838; 5.823.678; 5,823,679. Other U.S. and Foreign Patents Pending.

not model changes, whenever an improvement is possible. This affords our customers the latest in

ENGINEERING, INC.

INC. All rights reserved. This document may not be copied, photocopied, reproduced, translated, or reduced able form, in whole or in part, without the prior written consent of OMEGA ENGINEERING, INC.

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project