Split System Submittal Data

System:

KE12NB41 Indoor: CS-KE12NB41 Outdoor: CU-KE12NK1

Ceiling Recessed Heat Pump

Job Name:

Location:

Engineer:

Submitted to:

Submitted by:

Reference:

Approval:

Date:

Construction:

Unit#:

Drawing#:

General Data

Power (V/P/Hz)

Circuit Ampacity (A)

Fuse Size, Max.(A)

115/1/60

20

20

Compressor

No. Used

R.L. Amps - L.R. (A)

Crankcase Heater (W)

Outdoor Unit

Fan Type

Dia (in.) - No. Speeds

Type Drive

No. Poles (RPM)

No. Motors (W)

F.L. Amps (A)

Coil Type

Fin Type - Pipe Type

Rows - F.P.I.

Face Area (sq.ft.)

Tube Size (in.)

Indoor Unit

Fan Type

Diameter and Depth

No. Speeds

No. Poles (RPM, High)

No. Motors (W)

CFM (Hi/Med/Low) Cooling

CFM (Hi/Med/Low) Heating

Operating Sound-Hi/Me/Lo/ dB-A

(H-C)

F.L. Amps

Coil Type

Fin Type - Pipe Type

Rows - F.P.I.

Face Area (sq. ft.)

Tube Size (in.)

Drain Connection Size (in.)

Refrigerant

Lbs. - R410a (outdoor unit)

DC Twin Rotary (Inverter)

1

9.8/10.6-20

20

Propeller

15-3/4”-Auto(Hi and multi step)

Direct / DC Motor

8-750

1-30

0.6

Aluminum Fin and Copper Pipe

Corrugated Plate - Inner Rifled

2-18.1

3.95

5/16”

Turbo

12-5/8” x 5-3/4”

Auto and 3 steps

8-470 Cool / 520 Heat

1-30

235 / 206 / 194

268 / 247 / 224

44 / 40 / 36

0.346

Aluminum Plate Fin & Copper Tube

Slit Plate - Inner Rifled

2-18.1

2.94

9-32”

23/32”

R410A

2.43

Refrigerant Control Electronic Expansion Valve

Refrigerant Tubing Connections Flare

Line Length, Max (ft.) 65’

Line Heigth Difference, Max (ft.) 23’

Line Size (in. O.D. Discharge)

Line Size (in. O.D. Suction)

Pre-charge, tubing length at shipment

1/4”

3/8”

25’

Dimensions (HxWxD)

Indoor Unit (Crated) (in.) 11-13/32” x 24-13/16” x 28-1/8”

Indoor Unit (Uncrated) (in.) Body 11-5/32” x 22-5/8” x 22-5/8”

Indoor Unit (Uncrated) (in.) Body and Panel

Outdoor Unit (Crated) (in.)

Outdoor Unit (Uncrated) (in.)

12-5/16” x 24-19/32” x 24-19/32”

23-5/8” x 33-11/16” x 14-1/4”

21-9/16” x 28-11/32” x 10-1/16”

Weight (lbs.)

(Indoor) Net

(Indoor) Shipping

(Outdoor) Net

(Outdoor) Shipping

35.3

41.9

77.2

83.8

(Indoor) Shipping Volume (cu.ft.) 4.59

(Outdoor) Shipping Volume (cu.ft.) 6.35

Performance Data @ ARI Standard Conditions (115V)

Cooling

Total Capacity (BTU/H)

Sensible Capacity (BTU/H)

Latent Capacity (BTU/H)

SEER

Dehumidification (Pints/H)

Amps (A)

Power Inputs (W)

Outdoor Sound Rating (dB-A)

11,900 (3,000-11,900)

7,200

4,700

16

4.26

12.6 (2.5-12.6)

1260 (250-1260)

51

Heating

Total Capacity (BTU/H)

HSPF

Amps (A)

Max Amps

Power Inputs (W)

Back-up Strip Heater

Outdoor Sounds Rating (dB-A)

13,600 (3,000-13,600)

8.5

14.6 (2.5-14.6)

1,460 (250-1,460)

0.00/0.00

51

Features

Controls

Remote Controller

Temperature Control

Timer

Microprocessor

LCD Wireless Type, Temp. Sensor

Built In

IC Thermistor

24 Hour, Single Event, ON/OFF

Timer

Night Setback

One Hour OFF Timer

Included

Included

Air Louver, 4 Way Panel, Control (CZ-18BT1U)-4-Automatic/

Sweep/Step

Power Failure Automatic Restart Included

Condensate Drain Pump Included

Self-Diagnosis

High Power

Quiet Operation

Air Filter

Included

Included

Included

Washable, Anti-Mold

Options

Refrigerant Line Set

Fresh Air Intake

Air Duct Extension

Hard Wired Remote Control

Non-Removable, Locking

Remote-Control Bracket

Available

Knock-Out (Dia. 3-7/8”)

N/A

Available / Model Number-CZ-

RD515U

Available

Operating Range Indoor Air Intake Temp Outdoor Air Intake Temp

Cooling (Max)

Cooling (Min)

Heating (Max)

Heating (Min)

95F DB/71F WB

67F DB/57F WB

80F DB/67F WB

-DB/-WB

115F DB

0F DB

75F DB/65F WB

0F DB

Panasonic North America

Air Conditioning Division

1690 Roberts Blvd., NW, Suite 110

Kennesaw, GA 30144 us.panasonic.com/aircon

Indoor Dimensions

AA

23-5/8 (600)

21-1/32 (534)

7

8

5

6

3

4

1

2

Air intake

Discharge outlet

Refrigerant tubing (liquid tube) dia. 1/4" (flared)

Refrigerant tubing (gas tube) dia. 1/2" (flared)

Drain tube connection port VP20 (outer dia. 1")

Power supply port

Suspension bolt hole (4 - 1/2" x 1-1/8" hole)

Fresh air intake duct connection port (dia. 3-7/8")

22-5/8 (575)

7

Center of panel

2-3/32

22-5/8 (575)

6-5/16 6-11/16 5

4-29/32

A View

8

Less than 31/32 Less than 31/32

6 3

24-19/32 (625)

14-3/32 (358)

2-3/32

1-27/32

Outdoor Dimensions

25/32

2

2

1

2

10-13/16

21-3/16

ID:23/32

4-ID:15/16

3-19/32

15/32

2

The length of the suspension bolts should be selected so that main unit), as shown in the figure at right. If the suspension

2 8 1 1 / 3 2 ( 7 2 0 ) 2 1 / 8

Wide tube service valve dia.3/8" (9.52)

Narrow tube service valve dia.1/4" (6.35)

6-3/32

Unit : inch (mm)

(852-0-0010-12700-0)

Panasonic North America

Air Conditioning Division

1690 Roberts Blvd., NW, Suite 110

Kennesaw, GA 30144 us.panasonic.com/aircon

19

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

advertisement