advertisement
®
MLZ6DT
Motorized Zoom Lens Control
Installation/Operation Manual
C517M Rev C (6/92)
1.0 WARNINGS
Prior to installation and use of this product, the following
WARNINGS should be observed.
1.
Installation and servicing should only be done by
Qualified Service Personnel and conform to all
Local codes.
2.
Unless the unit is specifically marked as a NEMA
Type 3, 3R, 3S, 4, 4X, 6, or 6P enclosure, it is designed for indoor use only and it must not be installed where exposed to rain and moisture.
3.
The product bears the following marks:
This symbol indiates that dangerous voltage constituting a risk of electric shock is present within this unit.
CAUTION:
TO REDUCED THE RISK OF ELECTRIAL SHOCK,
DO NOT REMOVE COVER. NO USER-SERVICE-
ABLE PARTS INSIDE. REFER SERVICING TO
QUALIFIED SERVICE PERSONNEL.
CAUTION:
RISH OF ELECTRIC SHOCK.
DO NOT OPEN.
This symbol indicates that there are important operating and maintenance instructions in the literature accompanying this unit.
4.
Only use replacement parts recommended by Pelco.
5.
After replacement/repair of this unit’s electrial components, conduct resistance measurements between line and exposed parts to verify the exposed parts have not been connected to line circuitry.
Please thoroughly familiarize yourself with the information in this manual prior to installation and operation.
Pelco • 3500 Pelco Way, Clovis, CA 93612-5699 • USA • www.pelco.com
(800) 289-9100 or (1-559) 292-1981 • FAX (800) 289-9150 or (1-559) 292-3827
International customers call (1-559) 292-1981 or FAX (1-559) 348-1120
2.0 SCOPE
The information contained within this manual covers the MLZ6DT Motorized Zoom Lens Control with the
24 VAC wall mount transformer power supply.
3.0 DESCRIPTION
The MLZ6DT is a desk top zoom lens control which provides remote control of zoom, focus, and iris functions for all Pelco motorized zoom lenses.
The MLZ6DT can also be used with lenses equipped with the AI700/AI701 auto iris servo assembly.
The servo in the AI700/AI701 detects the slightest change in video level and drives the iris motor to open or close the iris to maintain proper faceplate illumination. The MLZ6DT control allows for manual override of the auto iris functions for scenes requiring manual iris adjustment.
Front panel switches provide control of zoom and focus functions, with optional manual control of the iris.
Speed is adjustable through the front panel knob control.
3.1 OPTIONS
AI701
C06HWC
DT200
R300
Auto-iris servo for motorized zoom lenses with “ND” and “MS” in suffix.
Allows for fully automatic iris operation with manual override when used with MLZ6DT lens control.
Pre-wired, 6 foot (1.82 m) interconnecting with 14-pin control connector and butt splices on mating end.
(Compatible only when not used with the AI701.)
(UL)
Dual desk top mount kit; two units can be mounted side-by-side in one desk top chassis.
Rack mount kit for up to three (3) control modules.
2 Pelco Manual C517M Rev C (6/92)
4.0 INSTALLATION
4.1 CONNECTOR ASSEMBLY
Installation and/or testing will require you to assemble the connector parts provided. Fabricate the interconnecting cable according to the following steps (reference Figure 1).
1.
Slide part A of the cable clamp (item 1) over the end of the cable (item 1, part C) with the threaded end of the cable clamp facing the connector (item 5).
2.
If the cable has a diameter less than 1/2 inch (1.3
cm), slide the rubber boot (item 2) over the end of the cable and pull through the cable clamp to so that the boot encases the cable and forms a good seal.
3.
Strip back the cable jacket approximately 1-1/4 inches (3.2 cm) and separate the individual conductors (item 3).
5
4.
The contact pins supplied with the mating connector are the “crimp” type which may also be soldered if you so desired (item 4).
5.
After crimping or soldering the contact pins to the conductors, push them into the proper holes in the connector until they snap in place.
NOTE: Contacts cannot be removed from the connector without the use of the appropriate
AMP extraction tool which is available from
Pelco.
6.
Slide part A of the cable clamp toward the connector and screw the parts together. Attach part B (item
1) onto part A and connect both parts with the screws provided.
7.
Connect the cable assembly to the unit and seat the connector by twisting the locking collar until it snaps into position.
Refer to Figure 2 for wiring diagram.
threaded end of cable clamp A
1
B C
STEP 1
5 FLEXIBLE RUBBER BOOT
A
1
B
STEP 2
C
2
5 **
3
1
B 4
STRIP 1/8"
A
STEPS 3-7 C
CRIMP
WIRE
CRIMP
INSULATION
STRIP 1"
OUTSIDE
JACKET
OF CABLE
**
ITEM 5 DETAIL
15
9
4 1
5
10
22
28
33
37
34
FRONT VIEW
37-PIN CONNECTOR
3
29
16
23
7
THE MOST COMMONLY USED
CONNECTOR PIN-OUT CONFIG-
URATIONS ARE SHOWN HERE.
REFERENCE THE CONNECTOR
DRAWING APPLICABLE TO
YOUR SITUATION.
11
14
8
3
20
25
28
1
26
FRONT VIEW
28-PIN CONNECTOR
3
15
21
4
6
14
FRONT VIEW
14-PIN CONNECTOR
12
8
9
1
4
9
FRONT VIEW
9-PIN CONNECTOR
2 1
6
3
10
14
16 15
FRONT VIEW
16-PIN CONNECTOR
1
11
7
4
7
Figure 1. Connector Assembly
Pelco Manual C517M Rev C (6/92) 3
1
12
3
14
1
6
5
2
3
4
1
RED 10
IRIS
2
13
12
MANUAL IRIS*
LENS COM
ZOOM
5
4
2
BLUE
BLK
WHT
8 GND G YEL
11
CONTROL
OUTPUT
FOCUS 3
P3
LENS INPUT
GRN
*NO CONNECTION REQUIRED EXCEPT WHEN USED WITH A1700.
ALLOWS MANUAL IRIS CONTROL.
4
Figure 2. Wiring Diagram for Output Pin Assignments
Pelco Manual C517M Rev C (6/92)
5.0 OPERATION AND SYSTEM TEST
1.
Hook up the control cable between the output connector on MLZ6DT and the input connector on the lens (see Figure 3).
2.
Check that the video is connected from the camera to the monitor.
3.
Plug the mating connector of the wall mount transformer into the back of the MLZ6DT and plug the transformer into a 120 VAC source. The power indicator LED will light when power is applied.
4.
For manual operation, put the switch in the
MANUAL position. Observing the monitor, test for proper operation of zoom, focus, and iris functions with related switches on the front panel.
5.
Test for fast and slow speeds of all functions by observing their operation as the LENS SPEED knob on the front panel is adjusted.
NOTE: AUTO operation only works in conjunction with AI700 or AI701 auto iris servo units. If the lens is equipped with AI700 or
AI701, use the following guidelines to test auto operation (see Figure 4).
6.
Connect the AI700 or AI701 as shown in Figure 4.
Put the power switch in the AUTO/ON position. The
IRIS switch should not operate; ZOOM and FO-
CUS switches should operate normally. Observing the monitor, test operation of ZOOM and FOCUS switches. Next, turn the lens toward a dark area, and observing the monitor, check that the iris opens.
Move the lens back toward a lighter area, and observing the monitor, check that the iris closes.
6.0 MAINTENANCE
Under normal operating conditions and usage, maintenance of this equipment is not necessary. However, if maintenance should be required, consult Pelco or a qualified service technician.
COAX CABLE
WALL MOUNT
TRANSFORMER
CONTROL CABLE
MLZ6
Figure 3. Basic System Configuration
COAX CABLE
WALL MOUNT
TRANSFORMER
CONTROL CABLE
MLZ6
Figure 4. System Configuration Using AI700 or AI701 Auto Iris Servo
Pelco Manual C517M Rev C (6/92) 5
7.0 SCHEMATIC
6
Figure 5. MLZ6DT Schematic
Pelco Manual C517M Rev C (6/92)
8.0 SPECIFICATIONS
CONTROLS
Zoom:
Focus:
Manual Iris:
Auto-Iris:
Paddle switch TELE/WIDE
Paddle switch NEAR/FAR
Paddle switch OPEN/CLOSE
Paddle switch AUTO/MANUAL
Video Level: Knob adjustment (MLZA6DT only)
Speed: Knob adjustment
On/Off:
Pilot Lamp:
Rocker switch
Light emitting diode (LED)
(MLZ6DT)
Long life neon (MLZA6DT)
ELECTRICAL
Input Voltage: 120 or 230 VAC, 50/60 Hz
Output Voltage: ±2-12 VDC
Power
Consumption: 3-6 watts
Power Supply: 24 VAC, CT 400 mA wall mount transformer (MLZ6DT)
Output
Connector:
Circuit:
AMP CPC type, 14-pin (mate supplied)
Full wave power supply with solidstate drive
Cable
Requirements: Four (4) conductors plus ground; one
(1) additional conductor for manual override
Cable Distances: The following distances are approximate maximum recommended under the following conditions:
— Based on a 35mA load @ 9 VDC
— Single lens function activation
— Single common conductor in lens
cable
— 10% loss in voltage
22 Awg 797 feet (243 m)
20 Awg 1,267 feet (386 m)
18 Awg 2,015 feet (614 m)
NOTE: Video is limited to 500 feet on RG-
59 coax cable without equalization amplifier.
GENERAL
Construction:
Cover
Chassis
Panel
Dimensions
Steel, black polyester powder coat
Steel, zinc plated
Aluminum, black polyester powder coat with white silkscreen
See Figure 6
Weight Unit Shipping
MLZ6DT Series 3 lbs (1.35 kg) 5 lbs (2.25 kg)
MLZA6DT Series 4 lbs (1.8 kg) 6 lbs (2.7 kg)
Rating: NEMA 1
Figure 6. MLZ6DT Dimension Drawing
Pelco Manual C517M Rev C (6/92) 7
9.0 WARRANTY AND RETURN
INFORMATION
WARRANTY
Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment.
Exceptions to this warranty are as noted below:
• Five years on FT/FR8000 Series fiber optic products.
• Three years on Genex ® Series products (multiplexers, server, and keyboard).
• Three years on Camclosure ® and fixed camera models, except the
CC3701H-2, CC3701H-2X, CC3751H-2, CC3651H-2X, MC3651H-2, and MC3651H-2X camera models, which have a five-year warranty.
• Two years on standard motorized or fixed focal length lenses.
• Two years on Legacy ® , CM6700/CM6800/CM9700 Series matrix, and
DF5/DF8 Series fixed dome products.
• Two years on Spectra ® , Esprit ® , ExSite ™ , and PS20 scanners, including when used in continuous motion applications.
• Two years on Esprit ® and WW5700 Series window wiper (excluding wiper blades).
• Eighteen months on DX Series digital video recorders, NVR300
Series network video recorders, and Endura ™ Series distributed network-based video products.
• One year (except video heads) on video cassette recorders (VCRs).
Video heads will be covered for a period of six months.
• Six months on all pan and tilts, scanners or preset lenses used in continuous motion applications (that is, preset scan, tour and auto scan modes).
Pelco will warrant all replacement parts and repairs for 90 days from the date of Pelco shipment. All goods requiring warranty repair shall be sent freight prepaid to Pelco, Clovis, California. Repairs made necessary by reason of misuse, alteration, normal wear, or accident are not covered under this warranty.
Pelco assumes no risk and shall be subject to no liability for damages or loss resulting from the specific use or application made of the Products.
Pelco’s liability for any claim, whether based on breach of contract, negligence, infringement of any rights of any party or product liability, relating to the Products shall not exceed the price paid by the Dealer to
Pelco for such Products. In no event will Pelco be liable for any special, incidental or consequential damages (including loss of use, loss of profit and claims of third parties) however caused, whether by the negligence of Pelco or otherwise.
The above warranty provides the Dealer with specific legal rights. The
Dealer may also have additional rights, which are subject to variation from state to state.
If a warranty repair is required, the Dealer must contact Pelco at (800)
289-9100 or (559) 292-1981 to obtain a Repair Authorization number
(RA), and provide the following information:
1. Model and serial number
2. Date of shipment, P.O. number, Sales Order number, or Pelco invoice
number
3. Details of the defect or problem If there is a dispute regarding the
warranty of a product which does not fall under the warranty conditions
stated above, please include a written explanation with the product
when returned.
Method of return shipment shall be the same or equal to the method by which the item was received by Pelco.
RETURNS
In order to expedite parts returned to the factory for repair or credit, please call the factory at (800) 289-9100 or (559) 292-1981 to obtain an authorization number (CA number if returned for credit, and RA number if returned for repair).
All merchandise returned for credit may be subject to a 20% restocking and refurbishing charge.
Goods returned for repair or credit should be clearly identified with the assigned CA or RA number and freight should be prepaid. Ship to the appropriate address below.
If you are located within the continental U.S., Alaska, Hawaii or Puerto
Rico, send goods to:
Service Department
Pelco
3500 Pelco Way
Clovis, CA 93612-5699
If you are located outside the continental U.S., Alaska, Hawaii or Puerto
Rico and are instructed to return goods to the USA, you may do one of the following:
If the goods are to be sent by a COURIER SERVICE, send the goods to:
Pelco
3500 Pelco Way
Clovis, CA 93612-5699 USA
If the goods are to be sent by a FREIGHT FORWARDER, send the goods to:
Pelco c/o Expeditors
473 Eccles Avenue
South San Francisco, CA 94080 USA
Phone: 650-737-1700
Fax: 650-737-0933
This equipment contains electrical or electronic components that must be recycled properly to comply with Directive 2002/96/EC of the European Union regarding the disposal of waste electrical and electronic equipment (WEEE). Contact your local dealer for procedures for recycling this equipment.
8 Pelco Manual C517M Rev C (6/92)
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project