XSRING+ SHDSL Switch

XSRING+
SHDSL Switch
________________
Installation manual
Document reference : 9019209-01
_________________
INSTALLATION MANUAL
Content
1
PRODUCTS IDENTIFICATION ........................................................... 3
2
DELIVERY CONTENT AND ACCESSORIES..................................... 4
3
PRODUCT OVERVIEW ....................................................................... 5
4
DIMENSIONS....................................................................................... 7
5
CONNECTORS .................................................................................... 8
6
LED INDICATORS ............................................................................. 13
7
DIN RAIL MOUNTING ....................................................................... 14
8
COOLING ........................................................................................... 15
9
SUPPLY VOLTAGE........................................................................... 15
10
ENCLOSURE GROUNDING ............................................................. 15
11
RS232 INTERFACE ........................................................................... 16
12
RS485 INTERFACE ........................................................................... 16
13
DIGITAL INPUT AND OUTPUT......................................................... 17
14
LINE CABLE ...................................................................................... 18
15
PROTECTING THE SHDSL SWITCH FROM LIGHTNING .............. 18
16
CONNECTING THE SHDSL SWITCH TO THE LINE....................... 19
17
CONNECTING A PC FOR CONFIGURATION ................................. 21
18
FIRST CONFIGURATION.................................................................. 22
19
FURTHER SET UP MODIFICATIONS .............................................. 23
20
RESTORING THE FACTORY DEFAULT CONFIGURATION.......... 23
Page 2
XSRING+
INSTALLATION MANUAL
1
Products identification
BP2230
BP2220
BP2400
2230
2400
XSRING+
2220
Switch SHDSL XSRING+
Min supply V. VDC
Max supply V. VDC
10
60
10
30
10
60
10
60
10
30
10
60
SHDSL ports
Max data rate *
(Mb/s)
Ethernet ports
10-100 Mb/s
RS232
RS485 2 wires
By-pass function
RSTP
Failsafe ring
VLAN,
SNMP
QoS DiffServ
Html Configuration
Serial gateway
RAW TCP & UDP
telnet, modbus
unitelway
2
5.6
2
5.6
2
5.6
2
5.6
2
5.6
2
5.6
4
2
2
4
2
2
0
0
N
N
Y
Y
Y
Y
Y
0
1
1
N
N
Y
Y
Y
Y
Y
2
2
0
N
N
Y
Y
Y
Y
Y
2
0
0
Y
Y
Y
Y
Y
Y
Y
0
1
1
Y
Y
Y
Y
Y
Y
Y
2
2
0
Y
Y
Y
Y
Y
Y
Y
2
* Data rate in the standard mode; report to the user manual for detailed
information.
XSRING+
Page 3
INSTALLATION MANUAL
2
Delivery content and accessories
The product itself is delivered with a CD including the user manual and the
eticfinder software tool with which you can discover the IP address of any
product manufactured by ETIC TELECOM and connected to an Ethernet
network. 1
Accessories to order separately
RS232 cable with : RJ45 to DB9 male – 1 meter long
RS232 cable with : RJ45 to DB9 female – 1 meter long
Surge arrester
Page 4
reference
CAB592
CAB593
PS02-1
XSRING+
INSTALLATION MANUAL
3
Product overview
For detailed information, report to the user manual.
Daisy chain network without or with the By-pass function
(XSRING+BP only)
Point to point transmission over one or two twisted pairs to multiply the data
rate and provide a backup link
XSRING+
Page 5
INSTALLATION MANUAL
Complex redundant topologies using the RSTP protocol
Failsafe ring network using the fast proprietary algorithm
Page 6
XSRING+
INSTALLATION MANUAL
4
Dimensions
All models
XSRING+
Page 7
INSTALLATION MANUAL
5
Connectors
XSRING+2400
XSRING+2220
XSRING+2230
Page 8
XSRING+
INSTALLATION MANUAL
XSRING+BP2400
XSRING+BP2220
XSRING+BP2230
XSRING+
Page 9
INSTALLATION MANUAL
Position
1
2
Position
1
2 positions screw terminal : Supply voltage 1
Protected against reverse polarity
Signal
Function
Power 1 +
10-30 VDC :
XSRING+2220 & XSRING+BP2220
Power 1 -
10-60 VDC :
XSRING+2400 XSRING+2230
XSRING+BP2400 XSRING+BP2230
0V isolated from the enclosure
2 positions screw terminal : Supply voltage 2
Protected against reverse polarity
Signal
Function
Power 2 +
10-30 VDC :
XSRING+2220 & XSRING+BP2220
10-60 VDC :
XSRING+2400 XSRING+2230
XSRING+BP2400 XSRING+BP2230
0V isolated from the enclosure
2
Power 2 -
Position
1
2
3
4
4 positions screw terminal : Digital input and output
Signal
Function
3V3
3 V DC provided by the XS+
In
Digital input
F+
Digital output + (max 50Vdc - 0,6A)
FDigital output -
Page 10
XSRING+
INSTALLATION MANUAL
Position
1
2
XSRING+2220 XSRING+2230 XSRING+2400
2 positions screw terminal : Shdsl 1 & Shdsl 2
Signal
Function
Line
SHDSL line conductor (the two wires can be inverted)
Line
SHDSL line conductor (the two wires can be inverted)
XSRING+BP2220 XSRING+BP2230 XSRING+BP2400
2 positions screw terminal : Shdsl 1 & Shdsl 2
Position
1
2
Signal
Line
Line
Function
SHDSL line conductor if the by-pass function is not used
SHDSL line conductor if the by-pass function is not used
XSRING+BP2220 XSRING+BP2230 XSRING+BP2400
2 positions screw terminal : Shdsl 1 by-pass & Shdsl 2 by-pass
Position
1
2
Signal
Line
Line
Function
SHDSL line conductor if the by-pass function is used
SHDSL line conductor if the by-pass function is used
RJ45 connector : Ethernet
Position
1
2
3
4
5
6
7
8
Signal
Tx +
Tx Rx +
N.C
N.C
Rx N.C.
N.C.
Position
1
2
Signal
A
B
Function
Emission polarity +
Emission polarity Reception polarity +
Reception polarity 2 positions screw terminal : RS485
XSRING+
Function
RS485 polarity A
RS485 polarity B
Page 11
INSTALLATION MANUAL
Position
1
2
3
4
5
6
7
8
Pos.
1
2
3
4
5
6
7
8
Page 12
RS232 RJ45 connector
(To connect a DCE to the RS232 port)
Circuit
Dir
Function
DTR - 108
OUT
Data terminal ready
TD - 103
OUT
Data Emission
RD - 104
IN
Data Reception
DSR - 107
IN
Data set ready
SG - 102
Ground
Not used
OUT
CTS - 106
IN
Clear to send
RTS - 105
OUT
Request to send
RS232 RJ45 connector
(To connect a DTE to the RS232 port)
Circuit
Dir
Function
CD - 109
OUT
Carrier detect
RD - 104
OUT
Data Reception
TD - 103
IN
Data Emission
DTR - 108
IN
Data terminal ready
SG - 102
Ground
DSR - 107
OUT
Data set ready
RTS - 105
IN
Request to send
CTS - 106
OUT
Clear to send
XSRING+
INSTALLATION MANUAL
6
Led indicators
Led
Status
Description
1
ON green
The supply voltage 1 is present
2
ON green
The supply voltage 2 is present
ON green
ON red
ON green
ON red
OFF
Flashing slowly
Shdsl 1
Shdsl 2
ON
The unit is ready
At power on : The product is starting
Otherwise : Product failure
Failsafe ring mode / the ring is established
Failsafe ring mode/ failure has been
detected
The XSRING+ is not in the failsafe ring
mode
SHDSL connection
SHDSL connection established
Flashing quickly
SHDSL connection established ; traffic
across the line
RS232 *
RX
Flashing quickly
Bytes received from the RS232
RS232 *
TX
Flashing quickly
Bytes transmitted to the RS232
RS485 **
RX
Flashing quickly
Bytes received from the RS485
RS485 **
TX
Flashing quickly
Bytes received to the RS485
* XSRING+2220, XSRING+2230 XSRING+BP2220, XSRING+BP2230
** XSRING+2220, XSRING+BP2220
XSRING+
Page 13
INSTALLATION MANUAL
7
DIN rail mounting
Mounting the unit on the DIN rail
This unit should be mounted on 35
mm DIN-rail, horizontally mounted.
Removing the unit from the DIN rail
Page 14
XSRING+
INSTALLATION MANUAL
8
Cooling
To avoid obstructing the airflow around the unit, the spacing must be at least 25
mm above and below, and 10 mm left and right.
9
Supply voltage
XSRING+2400, XSRING+BP2400 : 10 to 60 VDC
XSRING+2230, XSRING+BP2230: 10 to 60 VDC
XSRING+2220, XSRING+BP2220 : 10 to 30 VDC
The consumption is 6 W
10
Isolation and enclosure grounding
The enclosure of the product is metallic; It must be grounded.
The minus polarity of the supply voltage is common with the minus voltage of
the electronic board – usually called 0 V - and is isolated from the enclosure.
Moreover, the Ethernet signal and the SHDSL signal are isolated through
transformers. It is why
• the versions XSRING+2400 and XSRING+BP2400 are fully isolated. The
common mode voltage must not exceed 1500 V.
• The versions XSRING+2220 and XSRING+BP2220 provide the minus
voltage through the RS232 interface and through the RS485 interface.
• The versions XSRING+2230 and XSRING+BP2230 provide the minus
voltage through the RS232 interface.
XSRING+
Page 15
INSTALLATION MANUAL
11
RS232 interface
The RS232 data rate can be set from 1200 to 115200 b/s with parity (even /
odd) or no parity.
The data terminal must be less than 10 meters far from the modem.
Cables can be provided to connect the product to DTE and DCE as follows :
RS232 cables (L=1m)
Code
CAB592
CAB593
CAB609
12
User connector
SubD 9 male
SubD 9 female
Wires
Cable function
To connect a DCE to the XSRING+
To connect a DTE to the XSRING+
To connect a device providing a specific
connector
RS485 interface
The RS485 serial interface is
provided on the front panel 2
pins screw-block.
Polarisation resistors
Two 10 Kohm bus polarisation
resistors are included inside the
product.
-
+
10 KOhm
B(+)
A(-) 10 KOhm
RS485
Remark :
The RS485 interface of the XSRING+1220 or 2220 is made for connecting only
one device at short distance, inside the same cabinet for instance, and at low
data rate up to 19200 b/s;
If the RS485 line has to be longer, one of the devices connected to the RS485
line must provide standard polarisation resistors, and a 150 Ohm termination
resistor must be connected at each end of the line.
Page 16
XSRING+
INSTALLATION MANUAL
13
Digital input and output
Digital output :
Max. voltage : 48 VDC
Max. current : 500 mA
Digital input :
Maximum voltage : 20
VDC
IPL router
Digital input
3V3
5
In
6
Digital output
F+
7
+
FV
8
I max = 0,5 A
XSRING+
V < 48 VDC
I < 0,5 A
Page 17
INSTALLATION MANUAL
14
Line cable
Twisted pair
The XSRING+ shdsl switch is designed to be connected to one or several telephone grade
twisted pairs.
The conductor diameter must be included between 0.4 mm and 1 mm.
Shielded cable
It is better to use a shielded cable.
The shield must be connected to the earth at one of its ends.
The shield decreases the influence of the electromagnetic ambient noise on the shdsl
signal.
Moreover, the shield protects the XSRING+ shdsl switch against lightning.
Electrical power cable
Two power conductors can be used instead of a twisted pair to set an shdsl connection.
However, because the two wires are not twisted, the ambient electrical noise may disturb
the transmission.
Compared to the transmission over a twisted pair, the maximum distance between two
SHDSL switches is decreased.
Cross talk
If the cable is made of several pairs, each pair can be used to transmit a particular shdsl
connection ; however the shdsl signal transmitted in one pair may disturb the shdsl signal
transmitted in another one, and, in some cases, may decrease the effective data rate of
both shdsl connections.
15
Protecting the shdsl switch from lightning
if the line is exposed to lightning, we advise to use an surge arrester at each
end of the line and to connect the shield of the cable to the earth.
Page 18
XSRING+
INSTALLATION MANUAL
16
Connecting the shdsl switch to the line
The SHDSL signal is not polarised ; it is why the two conductors of one line can
be inverted.
16.1
Point to point connection using 1 or 2 twisted pairs
The XSRING+2XXX provides two SHDSL interfaces.
Two twisted pairs can be used to set a connection between two SHDSL
switches. In that case, the effective data rate will be the double compared to a
connection using only one pair.
We recommend to wire the first line from port 1 of the first XSRING+ to the port
1 of the second XSRING+ as shown below in order to make the configuration
and the diagnostic easier.
16.2
Multidrop or ring connection
If the SHDSL switches are connected to shape a multidrop network or a ring
network, we recommend to connect the lines as shown below .
In that way, the configuration of each SHDSL switch will be similar.
XSRING+
Page 19
INSTALLATION MANUAL
16.3
By-pass function
To enable the by-pass function, connect the line1 to the “1 by-pass” screw
block and the line 2 to the “2 by-pass” screw block as shown below.
.
Page 20
XSRING+
INSTALLATION MANUAL
17
Connecting a PC for configuration
The SHDSL switch is configured with an html browser ; no additional software
is needed.
HTML browser : Using Internet explorer 8 is advised.
Administration server address :
The administration html server is located at the LAN IP address of the SHDSL
switch .
The factory IP address is192.168.0.128.
First set up :
For the first configuration, we advise to connect the PC directly to the LAN
interface of the SHDSL switch..
Network IP address :
Later in the text, we often speak of “network IP address”.
We mean the lowest value of the addresses of the network.
For instance, if the netmask of a network is 255.255.255.0, the network IP
address of that network is X.Y.Z.0.
ETIC FINDER software tool :
The ETIC FINDER software tool delivered with the product enables you to
detect any product manufactured by ETICTELECOM and connected to an
Ethernet network.
XSRING+
Page 21
INSTALLATION MANUAL
18
First configuration
Step1 : Set up the PC connection
Select the Windows Start button and Control panel
• Double click the network connection icon.
• Double click the Network Icon
The local area connection status dialog box is displayed.
• Click the Properties button.
The local area connection properties dialog box is displayed.
• Select the Internet protocol (TCP/IP) choice and then click Properties
The Internet protocol (TCP/IP) Properties dialog box is displayed .
• Assign to the PC an IP address in accordance with the router’s IP address ;
for instance :
IP address 192.168.0.100
Subnet mask : 255.255.255.0
Default gateway : 192.168.0.128
• Close the html browser, if it was open prior to the network changes.
Step 2 : Connect the PC to the router with a crossed or straight Ethernet
cable
Step 3 ; Launch the
browser
• Launch the web
browser.
Select the factory IP
address of the router :
192.168.0.128.
.
Page 22
XSRING+
INSTALLATION MANUAL
19
Further set up modifications
Modifications can be carried out from the LAN interface, or remotely through
the line.
20
Restoring the factory default configuration
A push-button is located at the top of the product.
Restoring temporarily the factory default configuration
When the push-button is pressed while the unit is running, the factory default
configuration is temporarily restored : The IP address of the html server is
192.168.0.128.
However, the current configuration is not lost. The parameters of the current
configuration are displayed as usually.
Deleting the current configuration and restoring the factory default
configuration
When the power is switched ON while the push-button is pressed, the current
configuration is deleted and the factory default configuration is restored.
XSRING+
Page 23
The XSRING+ SHDSL switch is designed and manufactured by
ETIC TELECOM
13 Chemin du vieux chêne
38240 MEYLAN
FRANCE
Hotline : + 33 4-76-04-20-05
FAX : + 33 4-76-04-20-01
E-mail : hotline@etictelecom.com