BTS Touch Exit Button

Installation Instruction

Specifications

Mode BTS-100

Operating Voltage

Current Draw

12~24VDC

30~60mA/12VDC

40~80mA/24VDC

Relay contact output

Com,N/C,N/O

Relay rating 3A/30VDC

BTS-115-ANSI,115-S

12~24VDC

30~50mA/12VDC

40~60mA/24VDC

Com,N/C,N/O

3A/24VDC

BTS-85UK

12~24VDC 12~24VDC

20~40mA/12VDC

20~50mA/24VDC

60~100mA/12VDC

80~120mA/24VDC

12~24VDC

30~60mA/12VDC

40~80mA/24VDC

Com,N/C,N/O Com,N/C,N/O Com,N/C,N/O

3A/24VDC

BTS-400ANSI,300

3A/24VDC

BTS-486

3A/24VDC

Relay strike time

LED status indication

Temperature

Other

1~30 seconds

Green(Relay)

-20~+70ºC

1~30 seconds

Green(Relay)

-20~+70ºC

1~30 seconds

Green(Relay)

-20~+70ºC

1~30 seconds 1~30 seconds

2x6 levels of LED indicator

-20~+70ºC

2x6 levels of LED indicator

-20~+70ºC

N/O,N/C output setting

Wiring Diagram

The BTS touch sensitive exit button has

N.O. and N.C. contact output and can be connected directly to a electromagnetic lock or a proximity reader in series (or in parallel).

Control Device (Outdoor)

Relay output control

Fig.A

In Fig.A, BTS controls the fail-safe locking device directly by series connection. BTS relay time is door-opening time.

Power

Supply

1 30 sec.

Relay Timer

Locking Device

(fail-safe)

BTS Touch Sensitive Switch (Indoor)

Fig.B

In Fig.B, BTS controls the fail-secure locking device directly by parallel connection. BTS relay time is door-opening time.

Control Device (Outdoor)

Relay output control

Locking Device

(fail-secure)

1 30 sec.

Relay Timer

Power

Supply

BTS Touch Sensitive Switch (Indoor)

Note:

1. Make sure that the power input and relay rating output (3Amp/24VDC) are correct.

2. Make sure that the “+” and “-” wires are connected correctly.

3. The door strike or relay must have a varistor or a diode across the door strike terminals to suppress the

back EMF of the strike. Failure to do so will damage the relay contacts and electronic omponents, or

even burn the controller.

Copyright © GIANNI Industries,Inc.All rights reserved.

P-MU-BTS Ver.D Published 2011.03.18

Illustration

BTS Touch Exit Button

Base

Slot hole

LED

Vandal resistant screw

Stopper

Touch panel

The relay will send the signals from N.C. into N.O. contact after your finger or a metal object touches the touch panel.

Time delay can be adjusted from 1 to 30 seconds.

JP setting

Relay output

(Touch)

Relay output

(Touch)

(Light stay on)

Relay output

Relay output

(Light flash)

(Green)

(Touch)

(Red)

(Touch)

(Green)

(Touch)

(Off)

(Touch)

(Red)

(Touch)

(Off)

(Touch)

(Red)

(Green)

(Off)

(Green)

(Off)

(Red)

BTS-400-ANSI,300,486

Relay contact output

(dry contact)

12~24 VDC power input

JP setting

Relay Timer

(Sec.)

Warranty

The product is warranted against defects in material and workmanship while used in normal service for a period of 1 year from the date of sale to the original customer. The GEM policy is one of continual development and improvement; therefore GEM reserves the right to change specifications without notice.

Copyright © GIANNI Industries,Inc.All rights reserved.

P-MU-BTS Ver.D Published 2011.03.18

advertisement