Spectra QM95 User guide

Add to My manuals
2 Pages

advertisement

Spectra QM95 User guide | Manualzz

QM95 Quick Measure

Distance Meter

User Guide

Introduction

Thank you for choosing the Spectra Precision QM95 from the Trimble family of precision products. This easy-to-use distance measuring tool will allow you to measure distances quickly, accurately and reliably.

Before using the Quick Measure, read this operator’s manual carefully.

Included is information about operation, safety and maintenance.

Ensure that the operating instructions are with the laser distance meter when it is given to other persons.

Your comments and suggestions are welcome; please contact us at:

Trimble Spectra Precision Division

8261 State Route 235

Dayton, Ohio 45424 USA

Phone: +1 (937) 203-4419

Fax:

+1 (800) 527-3771

+1 (937) 482-0030

Internet: www.trimble.com/spectra

Features

Measure reference

Add Button

Subtract Button

Side Measure

Button www.trimble.com/spectra

– 2 –

Quick Start Guide

Unit OFF

Single Measure

Press Press Time Press 2

Short

Press Time

Short

Press 3 Press Time Comment

Long Beeps if sound is on Continuous Measure

Unit ON

Change measure reference

Area

Addition

Subtraction

Sound on / off

Units of measure change

Clear previous action

Power off

Short

Short

Long

Short

Short

Short

Short

Long

Short Short

Cycle front or back

Adds next measure

Subtracts next measure

Cycle on / off

Cycle through units

Erase previous action

Included with the QM95: Pouch, unit, battery, user guide

Power ON / OFF

Liquid Crystal Display

(LCD)

Measure Buton

Clear Button

Area Button

Battery Access

Batteries - Installation

1. Open the battery compartment.

2. Remove the batteries from the packaging and insert them in the tool.

NOTE When installing batteries note the positive (+) and negative (-) markings on the housings

3. Close the battery compartment cover.

Protective overmolding

Features - LCD Detail

– 3 –

12.324m

Units of measure

3.112m

8.235m

6.507m

Flip-out tab extension

3rd prior measure

2nd prior measure

Previous measure

Current measure

– 7 –

General Operation

Single distance measurement

1) Switch on the laser beam by pressing the Measure Button.

2) Point the laser dot to the surface to be measured. (Default measure reference is from bottom of the tool).

3) Press the Measure Button once again. The measured distance will be displayed.

4) Press the Power On/Off Button to switch off.

Continuous measurement

1) Press and hold the Measure Button for 2 seconds to activate continuous measuring mode. The tool beeps during continuous measure mode if beeper is turned on.

2) Press the Measure Button again to stop continuous measure. When continuous measure is stopped, the last valid distance measurement is displayed on the result line.

Continuous measure can be useful to find the shortest distance to a wall or longest distance to a corner as shown.

Battery disposal - Some areas have regulations regarding the disposal of batteries. Be sure to dispose of discharged batteries properly.

CAUTION: The batteries should be removed when storing the laser more than 30 days.

– 4 –

Features - LCD Detail

Icon Description

Indicates laser is activated

Indicates measure reference is from back

Indicates measure reference is from front

Automatic detection of tab extension and indicates measure reference is from extension

More bars indicate more battery power remaining

Flashing indicates it is time to change batteries

Unfavorable signal conditions

Hardware error. Switch unit on/off several time. If this symbol remains, contact your dealer

Temperature too high or too low

– 8 –

Power on/off options

1) The Quick Measure is designed to allow quick measurements by pressing the Measure Button to switch on the tool and activate the laser. In this case, measurement is accomplished when the Measure

Button is pressed the second time.

2) It is also possible to use the power button to switch on the tool. In this case, the Measure Button must be pressed once to activate the laser and a second time to accomplish a measurement.

Area

1) Press the measure button to turn on the unit (or the Clear button to clear)

2) Press the Area button

3) Press the Measure button to measure the first side as shown on the

LCD screen

4) Press the Measure button to measure the second side as shown on the LCD screen. The Area will be shown, along with both measures.

– 9 – – 10 – – 11 – – 12 –

General Operation

Addition and Subtraction

+ The next measure is added to the previous one

- The next measure is subtracted from the previous one

Clear button

Press the C button to clear the last reading. During area measures, the

C button clears the most recent measure, but preserves previous measures.

Settings menu (to change sound and unit of measure)

1) With the tool switched off, press and hold the Power On/Off Button for approximately 2 seconds to enter menu mode.

MENU m

2) Press + to cycle sound on or off

3) Press the – button to cycle through unit measure options: m in ft cm mm

1/8 in 1/16 in 1/32 in

1/8 ft 1/16 ft 1/32 ft yd

4) To close the menu, press and hold the Power On/Off Button for approximately 2 seconds. The tool is switched off and settings are saved.

– 13 –

General Care, Safety And Storage

General safety rules a) Check the condition of the tool before use. b) The user must check the accuracy of the tool after it has been dropped or subjected to other mechanical stresses.

c) Although the tool is designed for the tough conditions of jobsite use, as with other measuring instruments it should be treated with care.

Do not use prisms or mirrored surfaces

Distances can be measured from all stationary targets without a highly reflective surface, i.e. concrete, stone, wood, plastic, paper, etc. The use of prisms or other highly reflective targets is not permissible and, if attempted, may falsify the results.

Calibration Check

It is recommended to occasionally check the calibration of the tool.

1) Select a known measure distance about 1 to 5 meters (3 to 15 ft) that does not change over time.

2.) Measure the distance 10 times. Calculate the mean deviation from the actual distance. The measured mean deviation should be less than the typical accuracy tolerance of ± 1.5 mm ( ± 1/16 in)

– 14 –

Cleaning and drying

1. Blow dust off the lens.

2. Do not touch the lens with the fingers.

3. Use only a clean, soft cloth for cleaning. If necessary, moisten the cloth slightly with pure alcohol or a little water.

NOTE Do not use any other liquids as these may damage the plastic components.

Storage

The temperature limits for storage of your equipment must be observed, especially in winter / summer.

Remove the tool from its pouch if it has become wet. The tool, its carrying case and accessories should be cleaned and dried (at maximum

40°C). Repack the equipment only once it is completely dry. Check the accuracy of the equipment before it is used after a long period of storage or transportation.

Transport

Use the original packaging or packaging of equivalent quality for transporting or shipping your equipment.

CAUTION

Always remove the batteries before shipping the tool.

Specifications

Measuring Range*

Accuracy

Functions

0.1 to 200 m (1 to 650 ft)

± 1.0 mm typical (± 1/24 in)

Measure reference

Automatic shut off

Battery life (alkaline)

Operating temperature

Storage temperature

Power supply

Power indication

Laser Safety

Front, Rear, Rear with Extension tab

Laser - 1 minutes / Product - 10 minutes

8000 measures

-15⁰C to +50⁰C (3⁰F to 122⁰F)

-25⁰C to +65⁰C (-13⁰F to 149⁰F)

2 x AA x 1.5V

LCD 4 segments - 100%, 75% 50%, 25%

Laser Type / Power

Dimensions

Weight

635 nm visible red / < 1.0 mW

62 x 28.5 x 120 mm (2.4" x 1.2" x 4.7")

217 g (7.7 oz) with batteries

Dust & Water resistance IP54

Drop Performance 1.5 m (5 ft)

* Dependent upon several factors. See table next page

– 15 –

Trouble Shooting

Fault

The unit can’t be switched on.

No distances displayed by the unit.

Frequent error messages or the unit doesn’t measure.

Temperature indicator - symbol in the display

Unfavorable signal conditions - symbol in the display

General hardware fault - symbol in the display

Possible cause

The batteries are exhausted.

Incorrect battery polarity.

The button is faulty.

Measure Button was not pressed.

Unit was not switched on

Faulty display.

The target surface is too brightly lit by the sun.

The target surface is too shiny.

The target surface is too dark.

Bright sunlight towards the tool.

Temperature too high (>+50 °C / 122 °F)

Temperature too low (<-10 °C / 14 °F)

Insufficient reflected laser light.

Hardware fault

Measurement range:

Distance performance and measure speed is dependent upon several factors:

• Ambient lighting

• Target reflectivity

• Dust and particles in the air

• Temperature

Measurement range on standard target

Albedo Temp.

>5 -10⁰C to +50⁰C

Light

<1000 lx

Range

0.17 to 200 m

1

0.2

0.2

+10⁰C to +35⁰C

+10⁰C to +35⁰C

-10⁰C to +50⁰C

<1000 lx

<1000 lx

<1000 lx

0.17 to 120 m

0.17 to 55 m

0.17 to 50 m

1

0.2

1

0.2

+10⁰C to +35⁰C

+10⁰C to +35⁰C

-10⁰C to +50⁰C

-10⁰C to +50⁰C

Minimum measuring distance

Clearness

100000 lx 0.17 to 50 m

100000 lx 0.17 to 50 m

100000 lx 0.17 to 45 m

100000 lx 0.17 to 45 m

170 mm

>300 m

Remedy

– 16 –

Replace the batteries.

Insert the batteries correctly and close the battery compartment cover.

Contact Service

Press the Measure Button.

Press the Measure Button.

Contact Service

Measure from the other direction – sun from behind.

Take measurements from less shiny surfaces.

Use a lighter colored surface

Shade the unit.

Allow the unit to cool down.

Allow the unit to warm up.

Observe the minimum measuring distance (>200 mm / 8 inch from the front edge of the unit); clean the lenses; take the measurement from a different surface or use a target plate.

Switch the unit off and on again.

– 17 –

Laser Safety

Use of this product by people other than those trained on this product may result in exposure to hazardous laser light.

• Do not remove warning labels from the unit.

• The QM95 is a Class 2M (635 nm) laser product .

• Never look into the laser beam or direct it to the eyes of other people.

• Always operate the unit in a way that prevents the beam from getting into people‘s eyes.

– 21 –

– 18 –

Warranty

Trimble warrants the Quick Measure QM95 to be free of defects in material and workmanship for a period of 3 years. For the first 2 years,

Trimble or its authorized Dealer or Service Center will repair or replace, at its option, any defective part, or the entire product, for which notice has been given during the warranty period. For the 3rd year, an exchange fee may apply. This warranty period is in effect from the date the system is delivered by Trimble or its authorized Dealer to the purchaser, or is put into service by a Dealer as a demonstrator or rental component.

Any evidence of negligent or abnormal use, or any attempt to repair equipment by other than factory-authorized personnel or Trimble certified or recommended parts, automatically voids the warranty.

The foregoing states the entire liability of Trimble regarding the purchase and use of its equipment. Trimble will not be held responsible for any consequential loss or damage of any kind.

This warranty is in lieu of all other warranties, except as set forth above, including an implied warranty. Merchantability of fitness for a particular purpose is hereby disclaimed.

Customers should send products to the nearest authorized Factory,

Dealer or Service Center for warranty repairs, freight prepaid. In countries with Trimble Service Subsidiary Centers, the repaired products will be returned to the customer, freight prepaid.

– 22 –

– 19 –

Service Request

To locate your local dealer or authorized Trimble Service Center outside the U.S.A. for service, accessories, or spare parts, contact one of our offices listed below.

North-Latin America

Trimble / Spectra Precision Division

8261 State Route 235

Dayton, Ohio 45424-6383

U.S.A.

(888) 527-3771

(Toll Free in U.S.A.)

+1-937-203-4419 Phone

+1-937-482-0030 Fax www.trimble.com/spectra

Europe

Trimble Kaiserslautern GmbH

Am Sportplatz 5

67661 Kaiserslautern

GERMANY

Tel +49-(0)6301-71 14 14

Fax +49-06301-32213

Africa & Middle East

Trimble Export Middle-East

P.O. Box 17760

JAFZ View, Dubai

UAE

+971-4-881-3005 Phone

+971-4-881-3007 Fax

Asia-Pacific

Trimble Navigation Singapore PTE Ltd.

80 Marine Parade Road, #22-06

Parkway Parade

Singapore, 449269

+65 6348 2212 Phone

+65 6348 2232 Fax

China

Trimble Beijing

Room 2805-07, Tengda Plaza,

No. 168 Xiwai Street

Haidian District

Beijing, China 100044

+86 10 8857 7575 Phone

+86 10 8857 7161 Fax www.trimble.com.cn

– 23 –

– 20 –

Declarations

We declare, on our sole responsibility, that this product complies with the following directives and standards:

EN 50081-1, EN 61000-6-2, 2004/108/EC.

Designation: Laser range meter

Type: QM95

Notice to Our European Union Customers

For product recycling instructions and more information, please go to: www.trimble.com/environment/summary.html

Recycling in Europe

To recycle Trimble WEEE, call: +31 497 53 2430, and ask for the “WEEE associate,” or mail a request for recycling instructions to:

Trimble Europe BV c/o Menlo Worldwide Logistics

Meerheide 45

5521 DZ Eersel, NL

N324

© 2012, Trimble Navigation Limited. All rights reserved.

Reorder PN 1213-1220 Rev A (09/12)

advertisement

Related manuals

Frequently Answers and Questions

What is the operating temperature range of the Spectra QM95?
The operating temperature range is -15°C to +50°C (3°F to 122°F).
What is the storage temperature range of the Spectra QM95?
The storage temperature range is -25°C to +65°C (-13°F to 149°F).
What is the power supply for the Spectra QM95?
The power supply is 2 x AA x 1.5V.
What is the laser class of the Spectra QM95?
The laser class is Class II as per EN 60825-1:2007; IEC 60825-1:2007 CFR 21 § 1040 (FDA).
What is the measuring range of the Spectra QM95?
The measuring range is 0.1 to 200 m (1 to 650 ft).
What is the accuracy of the Spectra QM95?
The accuracy is ± 1.0 mm typical (± 1/24 in).
What are the measurement functions of the Spectra QM95?
The measurement functions include individual measure, continuous measure, area, addition, and subtraction.
What are the measure reference options of the Spectra QM95?
The measure reference options are front, rear, and rear with extension tab.
What is the display type of the Spectra QM95?
The display type is a Liquid Crystal Display (LCD).
What is the automatic shut off time of the Spectra QM95?
The automatic shut off time is 1 minute for the laser and 10 minutes for the product.

advertisement