Automatic Washer
PRODUCT MODEL NUMBERS
WTW6400S WTW6600S
RECESSED AREA AND CLOSET INSTALLATION
For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required (view 3). Louvered doors with equivalent air ventilation openings in the top and bottom are acceptable.
Electrical: 120-volt, 60 Hz, AC-only,
15 or 20 amp electrical supply. A time-delay fuse or circuit breaker and separate circuit is recommended.
"
"
"
17 "
(43.2 cm)
"
"
1 "
(2.5 cm)
27 1/2
"
(69.9 cm)
Front view
1 "
(2.5 cm)
" 27 "
(68.6 cm)
5
"
(12.7 cm)
Side view Closet door with vents
DRAIN SYSTEM OPTIONS
Standpipe drain system - wall or floor (view 1 & 2)
The standpipe drain requires a minimum diameter standpipe of
2" (5 cm). The minimum carry-away capacity can be no less than 17 gal. (64 L) per minute.
The top of the standpipe must be at least 39" (99 cm) high and no higher than 96" (244 cm) from the bottom of the washer.
Laundry tub drain system (view 1)
The laundry tub needs a minimum
20 gal. (76 L) capacity. The top of the laundry tub must be at least 39" (99 cm) above the floor and no higher than
96" (244 cm) from the bottom of the washer.
Floor drain system (view 2)
The floor drain system requires a siphon break that may be purchased separately.
The siphon break must be a minimum of
28" (71 cm) from the bottom of the washer. Additional hoses might be needed.
39"
(99 cm) 39"
(99 cm)
28"
(71 cm)
1 2 1
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
2
Ref. W10113000
02-02-07