Certificate of Acceptance Your submitted Report of Compliance

Certificate of Acceptance
Your submitted Report of Compliance (New) was approved as the contents below.
By issuing the acceptance No. and sending this email,
this is the completion of internet submission of your report of compliance.
Application Number: 3622-2970-9683-835
Acceptance Number: 3904724
Report of Compliance: New
Member Number: 726
Company: Quanta Computer Inc.
Address: No.188, Wen Hwa 2nd Rd., Kuei Shan Hsiang, Taoyuan Shien, Taiwan, R.O.C.
333
Responsible Person: Allen Chien
E-mail(Responsible Person)Allen_Chien@quantatw.com
Address(Contact Person): No.188, Wen Hwa 2nd Rd., Kuei Shan Hsiang, Taoyuan Shien,
Taiwan, R.O.C. 333
Department(Contact Person): ESBU EMI Section
Name (Contact Person):Wei-Chia Li
Phone(Contact Person): 886-3-327-2345#16299
FAX(Contact Person): 886-3-397-3614
E-mail(Contact Person): Wei-Chia.Li@quantatw.com
E-mail(Resipient of Certificate ):susanchen@gestek.com.tw
Acceptance No. of the original report:
Type of ITE: Server
Clasification of ITE: class_a
Clasification Code: A1
Type, etc. (Model No.): QR1-1600, QSSC810
Type to be added/modified:
Name of testing agency or company: Global EMC Standard Tech. Corp.
Radiated Test Site: R-1712
Conducted Test Site (mains ports): C-1831
Date of Testing_Other: December 18,2007-December 19,2007
Serial No. of the certificate of the test result: 0712034V-01
Measurement Distance: 10
Comment:
VOLUNTARY CONTROL FOR INTERFERENCE BY INFORMATION TECHNOLOGY
EQUIPMENT (VCCI)
Certificate of Test
January 2008
Quanta Computer
Inc.
Gestek
GESTEK
Gestek
Gestek GESTEK Gestek
estek GESTEK Gestek GEST
stek GESTEK Gestek GESTE
tek GESTEK Gestek GESTEK
ek GESTEK Gestek GESTEK
k GESTEK Gestek GESTEK
GESTEK Gestek GESTEK
Product Type
Model Number
Brand Name
Test Report Number
Date of Test
: Server
: QR1-1600, QSSC810
: Quanta
: 0712034V-01
: December 18, 2007-December 19, 2007
This Product was tested to the following standards at the laboratory
of Global EMC Standard Tech. Corp., and found Compliance.
Standards:
VCCI Class A / CISPR 22
http : //www.gestek.com.tw
GesTek EMC Lab
Sharon Chang, President
N0. 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen,
Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
TEL:886-2-2603-5321
FAX:886-2-2603-5325
Date: January 04, 2008
NVLAP LAB CODE 200085-0
Certificate
GESTEK Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
Tel:886-2-2603-5321 Fax:886-2-2603-5325
EMI Test Report
For
Quanta Computer Inc.
EUT: Server
Model Number:QR1-1600, QSSC810
Prepared for:
Quanta Computer Inc.
No.188, Wen Hwa 2nd Rd., Kuei Shan Hsiang, Taoyuan Shien, Taiwan, R.O.C.
333
Report By :
Global EMC Standard Tech. Corp.
No.3 Pau-Tou-Tsuo Valley, Chia-Pau
Tsuen, Lin Kou Hsiang, Taipei County,
Taiwan, R.O.C.
Tel : 886-2-2603-5321
Fax : 886-2-2603-5325
Test results given in this report only relate to the specimen(s) tested, calibrated or measured.
This report shall not be reproduced other than in full without the written consent of Gestek.
This report must not be use to claim product endorsement by NVLAP or any agency of the U.S. Government.
All data in this report are traceable to national standard or international standard.
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Listed Lab. of Commerce, FCC, VCCI.
Page 1 of 27
NVLAP Lab Code:200085-0
GESTEK Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
Tel:886-2-2603-5321 Fax:886-2-2603-5325
TABLE OF CONTENTS
DESCRIPTION
PAGE
1.
CERTIFICATION..................................................................................................... 3
2.
SUMMARY OF TEST RESULTS ............................................................................ 4
3.
GENERAL INFORMATION..................................................................................... 5
3.1
3.2
3.3
3.4
3.5
3.6
4.
PRODUCTION DESCRIPTION ............................................................................... 5
TEST MODES & EUT COMPONENTS DESCRIPTION ......................................... 6
CONFIGURATION OF THE SYSTEM UNDER TEST............................................. 9
BLOCK DIAGRAM OF CONNECTIONS BETWEEN EUT AND SIMULATORS ... 11
TEST METHODOLOGY ........................................................................................ 12
TEST FACILITY..................................................................................................... 12
CONDUCTED EMISSION MEASUREMENT ........................................................ 13
4.1
4.2
4.3
4.4
4.5
4.6
4.7
5.
TEST EQUIPMENTS............................................................................................. 13
BLOCK DIAGRAM OF TEST SETUP ................................................................... 13
CONDUCTED EMISSION LIMITS ........................................................................ 14
EUT CONFIGURATION ON MEASUREMENT ..................................................... 14
CONDUCTED EMISSION DATA .......................................................................... 14
OPERATING CONDITIONS OF THE EUT............................................................ 14
CONDUCTED EMISSION MEASUREMENT RESULTS....................................... 15
RADIATION EMISSION DATA ............................................................................. 17
5.1
5.2
5.3
5.4
5.5
5.6
5.7
6.
TEST EQUIPMENT ............................................................................................... 17
OPEN TEST SITE SETUP DIAGRAM .................................................................. 17
RADIATED EMISSION LIMIT................................................................................ 18
EUT CONFIGURATION ........................................................................................ 18
OPERATING CONDITIONS OF THE EUT............................................................ 18
RADIATED EMISSION DATA ............................................................................... 18
RADIATED EMISSIONS MEASUREMENT RESULTS ......................................... 19
PHOTOGRAPHS FOR TEST................................................................................ 21
6.1
6.2
TEST PHOTOGRAPHS FOR CONDUCTION EMISSION .................................... 21
TEST PHOTOGRAPHS FOR RADIATED EMISSION .......................................... 22
7.
PHOTOGRAPHS FOR PRODUCT ....................................................................... 23
8.
EMI/EMS REDUCTION METHOD DURING COMPLIANCE TESTING................ 25
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Listed Lab. of Commerce, FCC, VCCI.
Page 2 of 27
NVLAP Lab Code:200085-0
GESTEK Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
Tel:886-2-2603-5321 Fax:886-2-2603-5325
1.
CERTIFICATION
Applicant
EUT Description
Model Number
Brand Name
Serial Number
Tested Power Supply
: Quanta Computer Inc.
: Server
: QR1-1600, QSSC810
: Quanta
: N/A
: 100Vac/50Hz
MEASUREMENT PROCEDURE USED :
Agreement of Voluntary Control Council for Interference by Information Technology Equipment
Regulations for Voluntary Control Measures
VCCI Class A / ITE (V – 3 / 2007. 04 21th Edition)
VCCI Class A / ITE (V – 4 / 2007. 04 12th Edition)
.
For VCCI:
The measurement shown in the attachment where made in accordance with the procedures
indicated, and the maximum energy emitted by the equipment was found to be within the VCCI
limits applicable.
Date of Test: December 18, 2007-December 19, 2007
In order to ensure the quality and accuracy of this document, the contents have been thoroughly
reviewed by the following qualified personnel from GesTek Lab.
Documented By :
Tested By:
Susan Chen / adm. Dept. Technical Report Author Sky Chuang / eng. Dept. Engineer
Approved By :
Tonny Lin / General Manager
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Listed Lab. of Commerce, FCC, VCCI.
Page 3 of 27
NVLAP Lab Code:200085-0
GESTEK Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
Tel:886-2-2603-5321 Fax:886-2-2603-5325
2.
SUMMARY OF TEST RESULTS
STANDARD
TEST ITEM
TEST
RESULT
Conducted emission
(Mode 5)
PASS
The worst emission frequency is 0.5242 MHz.
And minimum passing margin is –21.97 dB.
The measurement uncertainty is 3.6 dB.
PASS
The worst emission frequency is 674.9944 MHz
at Horizontal.
And minimum passing margin is –4.59 dB.
Height of antenna is 3.0 M.
Angle of turntable is 143°.
The measurement uncertainty is 5.1 dB.
VCCI Class A
Radiated emission
(Mode 5)
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Listed Lab. of Commerce, FCC, VCCI.
REMARKS
Page 4 of 27
NVLAP Lab Code:200085-0
GESTEK Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
Tel:886-2-2603-5321 Fax:886-2-2603-5325
3.
GENERAL INFORMATION
3.1 PRODUCTION DESCRIPTION
Product Name
Model Number
Brand Name
Serial Number
Applicant
Address
:
:
:
:
:
:
Manufacturer
:
Address
:
Power Supply
Power Cord
:
:
Server
QR1-1600, QSSC810
Quanta
N/A
Quanta Computer Inc.
No.188, Wen Hwa 2nd Rd., Kuei Shan Hsiang, Taoyuan Shien,
Taiwan, R.O.C. 333
1.QUANTA COMPUTER USA INC.
2.QCG COMPUTER GMBH
3.TECH-FRONT (SHANGHAI) COMPUTER CO., LTD.
4.QUANTA MFG NASHVILLE L L C
1.45630 NORTHPORT LOOP, E FREMONT, CA 94538 USA
2.NEUENHOFSTRASSE 191 52078 AACHEN, GERMANY
3.2, LANE 58, SANZHUANG RD., SONGJIANG EXPORT
PROCESSING ZONE,SHANGHAI, 201613, CHINA
4.1621 HEIL QUAKER BLVD, LAVERGNE, TN 37086 USA
AC Input:100~240Vac, 50/60Hz, 5.2-2.5A
3pins, Detachable, 1.8m, Non-Shielded, Non-Core
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Listed Lab. of Commerce, FCC, VCCI.
Page 5 of 27
NVLAP Lab Code:200085-0
GESTEK Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
Tel:886-2-2603-5321 Fax:886-2-2603-5325
3.2 TEST MODES & EUT COMPONENTS DESCRIPTION
CPU
Mode1-Pre Scan Mode
(S/N:QMA-1000S)
Wolfdale 3.0G
Memory
Qimonda 1G *4
Test Mode
Seagate SATA 250G *2, M/N: ST3250820AS, BSMI ID: D33027
H.D.D.
Seagate SATA 500G *2, M/N: ST3500630NS, BSMI ID: D33027
DVD-ROM
SONY, M/N: CRX880A
Gigabit LAN
On Board (10/100/1000 Mbps)
VGA
On Board
Mother Board
Quanta, M/N: QMA-1000, S/N: QMA-1000S
S.P.S.
AcBel, 400W, M/N: FS6011, BSMI ID: R33567
Resolution
CPU
1280 x 1024, V-Sync: 75Hz
Mode2-Pre Scan Mode
Mode3-Pre Scan Mode
(S/N:QMA-1000V)
(S/N:QMA-1000S)
Wolfdale 3.0G
Conrroe 3.0G
Memory
Qimonda 1G *4
Test Mode
Seagate SATA 250G *2, M/N: ST3250820AS, BSMI ID: D33027
H.D.D.
Seagate SATA 500G *2, M/N: ST3500630NS, BSMI ID: D33027
DVD-ROM
SONY, M/N: CRX880A
Gigabit LAN
On Board (10/100/1000 Mbps)
VGA
On Board
Quanta, M/N: QMA-1000, S/N:
Quanta, M/N: QMA-1000, S/N:
QMA-1000V
QMA-1000S
AcBel, 400W, M/N: FS6011, BSMI ID: R33567
Mother Board
S.P.S.
1280 x 1024, V-Sync: 75Hz
Mode4-Pre Scan Mode
Mode5-Test Mode
(S/N:QMA-1000S)
(S/N:QMA-1000S)
Conrroe 2.93G
Wolfdale 3.0G
Resolution
Test Mode
CPU
DVD-ROM
Qimonda 1G *4
Seagate SATA 250G *2, M/N:
ST3250820AS, BSMI ID: D33027
Seagate SATA 750G *4, M/N:
ST3750640NS, BSMI ID: D33027
Seagate SATA 500G *2, M/N:
ST3500630NS, BSMI ID: D33027
SONY, M/N: CRX880A
Gigabit LAN
On Board (10/100/1000 Mbps)
VGA
On Board
Mother Board
Quanta, M/N: QMA-1000, S/N: QMA-1000S
S.P.S.
AcBel, 400W, M/N: FS6011, BSMI ID: R33567
Resolution
1280 x 1024, V-Sync: 75Hz
Memory
H.D.D.
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Listed Lab. of Commerce, FCC, VCCI.
Page 6 of 27
NVLAP Lab Code:200085-0
GESTEK Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
Tel:886-2-2603-5321 Fax:886-2-2603-5325
Mode6-Pre Scan Mode
(S/N:QMA-1000S)
Wolfdale 3.0G
Test Mode
CPU
Qimonda 1G *4
Memory
H.D.D.
Mode7-Pre Scan Mode
(S/N:QMA-1000S)
Wolfdale 2.33G
Seagate SAS 146G *4, M/N:
ST3146855SS, BSMI ID: D33027
Seagate SATA 750G *4, M/N:
ST3750640NS, BSMI ID: D33027
DVD-ROM
SONY, M/N: CRX880A
Gigabit LAN
On Board (10/100/1000 Mbps)
VGA
On Board
Mother Board
Quanta, M/N: QMA-1000, S/N: QMA-1000S
S.P.S.
AcBel, 400W, M/N: FS6011, BSMI ID: R33567
Resolution
CPU
1280 x 1024, V-Sync: 75Hz
Mode8-Pre Scan Mode
Mode9-Pre Scan Mode
(S/N:QMA-1000S)
(S/N:QMA-1000S)
Kentsfield 3.0G
Kentsfield 2.4G
Memory
Qimonda 1G *4
H.D.D.
Seagate SATA 750G *4, M/N: ST3750640NS, BSMI ID: D33027
DVD-ROM
SONY, M/N: CRX880A
Gigabit LAN
On Board (10/100/1000 Mbps)
VGA
On Board
Mother Board
Quanta, M/N: QMA-1000, S/N: QMA-1000S
S.P.S.
AcBel, 400W, M/N: FS6011, BSMI ID: R33567
Resolution
1280 x 1024, V-Sync: 75Hz
Test Mode
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Listed Lab. of Commerce, FCC, VCCI.
Page 7 of 27
NVLAP Lab Code:200085-0
GESTEK Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
Tel:886-2-2603-5321 Fax:886-2-2603-5325
Note:
1.According to pre-scan data, we determine the data (Mode 5) shown in this test report,
which reflects the worst-case data for each operation mode.
2.The EUT has series model numbers, because of the requirement of marketing;
The difference of model numbers are shown as below:
Server Series
SI
Quanta P/N Descriptions
Model Name
QR1-1600S
QR1-1600A
QR1-1600U
QR1-1600P
S48B MB ASSY(W/O
CPU/PCI 32/33)P
S48B MB ASSY (W/O CPU
/SAS PCI 32/33)V
S48B MB ASSY (W/O CPU)
BIGBY-V
S48B MB ASSY (W/O CPU)
QSSC
MB Series
Model Name
QR1-1600
QMA-1000S
QSSC-810
QR1-1600
QMA-1000V
QSSC-810
QR1-1600
QMA-1000T
QSSC-810
QR1-1600
QMA-1000U
QSSC-810
MCH
SAS
SAS
SAS
PCI 32/33
PCIex8
PCIex16
(NB)
Controller
connector
Slot
Slot
Slot
QMA-1000S
Bigby-P
LSI1064E
4
connector
4
v
v
v
QMA-1000V
Bigby-V
x
x
6
v
x
v
QMA-1000T
Bigby-P
LSI1064E
4
4
x
x
v
QMA-1000U
Bigby-V
x
x
6
x
x
v
MB Series
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Listed Lab. of Commerce, FCC, VCCI.
Page 8 of 27
NVLAP Lab Code:200085-0
GESTEK Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
Tel:886-2-2603-5321 Fax:886-2-2603-5325
3.3 CONFIGURATION OF THE SYSTEM UNDER TEST
Device
No.
21” COLOR
Monitor
M01-060
Modem
M03-018
PS2 Keyboard
K01-087
PS2 Mouse
M02-400
External USB 2.0
Hard Disk
U02-079
External USB 2.0
Hard Disk
U02-100
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Listed Lab. of Commerce, FCC, VCCI.
Configuration
Manufacturer
: COMPAQ
Model Number
: PE1143-41
Serial Number
: N/A
BSMI ID
: R31708
FCC ID
: N/A
Data Cable
: Shielded, detachable, 1.5m, VGA Cable
Power Cord
: 3Pin, Shielded, Detachable, 1.5m
Manufacturer
: ACEEX
Model Number
: 1414V
Serial Number
: 0046171
BSMI ID
: N/A
FCC ID
: IFAXDM1414
Data Cable
: T Type:RS232, Shielded, Detachable, 1.2m
Power Cord
: Non-Shielded, Detachable, 1.5m
Line
: Type:RJ11(4P2C), Detachable, 1.8m
Phone
: Type:RJ11(4P2C), Detachable, 1.8m
Manufacturer
: IBM
Model Number
: SK-8811
Serial Number
: 01979618
BSMI ID
: 3902B330
FCC ID
: N/A
Data Cable
: Shielded, Undetachable, 1.8 m
Manufacturer
: detrois
Model Number
: CanMouse CM-309
Serial Number
: N/A
BSMI ID
: R63159
FCC ID
: N/A
Data Cable
: Shielded, Undetachable, 1.5m
Manufacturer
: TERASYS
Model Number
: F12-UF
Serial Number
: A0100215-34P0030
BSMI ID
: 4912A002
Data Cable
: Shielded, detachable, 1.5m
AC Power Adaptor : YHI M/N:YS-1015-U12A BSMI ID:4872A185
Input:AC IN:100V 50/60Hz 35VA
Output: DC +12V ,1.25A
Manufacturer
: TERASYS
Model Number
: F12-UF
BSMI ID
: 4912A002
Data Cable
: Shielded, detachable, 1.5m
AC Power Adaptor : YHI M/N:YS-1015-U12A BSMI ID:4872A185
Input:AC IN:100V 50/60Hz 35VA
Output: DC +12V ,1.25A
Page 9 of 27
NVLAP Lab Code:200085-0
GESTEK Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
Tel:886-2-2603-5321 Fax:886-2-2603-5325
Device
No.
External USB 2.0
Hard Disk
U02-086
External USB 2.0
Hard Disk
U02-101
Far End Network
Server
-----
Configuration
TERASYS
F12-UF
4912A002
Shielded, detachable, 1.5m
YHI M/N:YS-1015-U12A BSMI ID:4872A185
Input:AC IN:100V 50/60Hz 35VA
Output: DC +12V ,1.25A
Manufacturer
: TERASYS
Model Number
: F12-UF
BSMI ID
: 4912A002
Data Cable
: Shielded, detachable, 1.5m
AC Power Adaptor : YHI M/N:YS-1015-U12A BSMI ID:4872A185
Input:AC IN:100V 50/60Hz 35VA
Output: DC +12V ,1.25A
Manufacturer
: ASUS
Model Number
: AP160R
HUB
-----
Power Cord
Manufacturer
Model Number
: Non- Shielded, Detachable, 1.8m
: D-Link
: DGS-1005D
Power Cord
: Non- Shielded, Detachable, 2.0m, 2pin
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Listed Lab. of Commerce, FCC, VCCI.
Manufacturer
Model Number
BSMI ID
Data Cable
AC Power Adaptor
:
:
:
:
:
Page 10 of 27
NVLAP Lab Code:200085-0
GESTEK Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
Tel:886-2-2603-5321 Fax:886-2-2603-5325
3.4 BLOCK DIAGRAM OF CONNECTIONS BETWEEN EUT AND SIMULATORS
Gigabit LAN
Far End Network Server
HUB
EUT: Server
Gigabit LAN
21” COLOR Monitor
HHHHHHHH
HHHHHHHH
HHHHHHHH
HHHHHHHH
Modem
External USB 2.0 Hard Disk
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Listed Lab. of Commerce, FCC, VCCI.
PS2
Mouse
Page 11 of 27
NVLAP Lab Code:200085-0
PS2
Keyboard
GESTEK Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
Tel:886-2-2603-5321 Fax:886-2-2603-5325
3.5 TEST METHODOLOGY
Both conducted and radiated testing were performed according to the procedures in
VCCI Article 5 Technical Requirements.
Radiated testing was performed at an antenna to EUT distance of
10
meters.
3.6 TEST FACILITY
Ambient conditions in the laboratory:
Items
Requirement
10-40
10-90
860-1060
Temperature (°C)
Humidity (%RH)
Barometric pressure (mbar)
VCCI SITE DESCRIPTION
NAME OF FIRM
Dec. 13, 1995 Certified by Voluntary Control Council
For Interference
By Information Technology Equipment JAPAN
Global EMC Standard Tech. Corp.
REGISTRANTION NUMBER
No. 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou
Hsiang, Taipei County, Taiwan, R.O.C.
R-1712, C-1831
Taiwan Accreditation
Recognized by the Council of Taiwan Accreditation
Foundation (TAF)
Foundation and confirmed to meet the requirements of
SITE LOCATION
ISO/IEC 17025.
Registration No.: 1082
Registration on TAF effective through Sep. 19, 2009
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Listed Lab. of Commerce, FCC, VCCI.
Page 12 of 27
NVLAP Lab Code:200085-0
GESTEK Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
Tel:886-2-2603-5321 Fax:886-2-2603-5325
4.
CONDUCTED EMISSION MEASUREMENT
4.1 TEST EQUIPMENTS
Item
Instrument
Manufacturer
Model
Serial No.
Next Cal. Date
1
Test Receiver
R&S
ESCS30
825022/003
2008.05.25
2
L.I.S.N.(EUT)
R&S
ENV216
100006
2008.05.28
3
L.I.S.N.(AE)
98091
2008.07.22
4
Pulse Limiter
R&S
ESH3-Z2
357.8810.52
2008.08.01
5
RF CABLE
GTK
N/A
GTK-E-A154-01
2008.11.26
6
50 Ohm Terminator
GTK
N/A
GTK-E-A130-01
N/A
7
Shielded Room
GTK
N/A
B5
N/A
ROLF HEINE NNB-2/16Z
4.2 BLOCK DIAGRAM OF TEST SETUP
4.2.1 TEST SETUP FOR EMISSION MEASUREMENT AT MAINS TERMINAL
EUT
40cm
Load
80cm
L.I.S.N.
(EUT)
Non-conducted table
80cm
L.I.S.N.
(AE)
Metal Ground Plane
Test Receiver
Transformer/ Convertor
Pulse Limiter
Filter(EUT)
Filter(AE)
Note: This is a reprehensive setup diagram for Table-top EUT.
For Floor-standing EUT, the table will be removed with all others setup condition remain the same.
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Listed Lab. of Commerce, FCC, VCCI.
Page 13 of 27
NVLAP Lab Code:200085-0
GESTEK Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
Tel:886-2-2603-5321 Fax:886-2-2603-5325
4.3 CONDUCTED EMISSION LIMITS
Maximum RF Line Voltage dB(µV)
Frequency
Class A
MHz
Class B
QUASI-PEAK AVERAGE QUASI-PEAK
AVERAGE
0.15 to 0.50
79
66
66 to 56
56 to 46
0.50 to 5.0
73
60
56
46
5.0 to 30
73
60
60
50
Remarks: In the Above Table, the tighter limit applies at the band edges.
4.4 EUT CONFIGURATION ON MEASUREMENT
4.4.1 FOR POWER LINE
The equipments, which are listed at 4.2, are installed on Conducted Emission Test to meet the
Commission requirement and operating in a manner which tends to maximize its emission
characteristics in a normal application.
The device under test, installed in a representative system as described in section 4.2, was
placed on a non-conductive table whose total height equaled 80 cm. The EUT was powered
through one L.I.S.N. whose the signal output was terminated to the receiver. The other
peripherals were powered from another L.I.S.N. whose the signal output was terminated by 50
Ohms terminator.
4.5 CONDUCTED EMISSION DATA
The measurement range of conducted emission, which is from 0.15 MHz to 30 MHz, was
investigated. The initial step in collecting conducted data is a spectrum analyzer peak scan of the
measurement range for all the test modes. Then the worst modes were reported the following
data pages.
The final measurement equal to Receiver reading plus a Correction factor when AMN insertion
loss bigger than 0.5dB, the receiver added the correction factor to the reading level automatically.
4.6 OPERATING CONDITIONS OF THE EUT
The exercise program used during conducted emission measurement was designed to exercise
the EUT in a manner similar to a typical use. The exercise sequence is listed as below:
1. Setup the EUT and simulators as shown on 4.3.
2. Turn on the power of all equipments.
3. Boot the Server from Hard Disk and setup the video to windows Server 2003, active all
devices.
4. Adjust to appropriate video resolution.
5. Connect the Far End Network Server and run test program “test.bat “.
6. The EUT exchange the information with the GesTek server via HUB.
7. Active other internal devices such as network function.
8. Run “DVD-Play” & “H.D.D. R/W” & “EMC” test program under windows Server 2003.
9. Server sent “H” pattern to monitor, make the “H” pattern full in the screen.
10. Server sent “H” pattern to parallel and serial port.
11. Repeat above steps.
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Listed Lab. of Commerce, FCC, VCCI.
Page 14 of 27
NVLAP Lab Code:200085-0
GESTEK Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
Tel:886-2-2603-5321 Fax:886-2-2603-5325
4.7
CONDUCTED EMISSION MEASUREMENT RESULTS
Date of Test
December 19, 2007
Temperature
26 ℃
60 %
EUT
Server
Humidity
Test Mode
Mode 5
Display Pattern
H Pattern
AC 100V/50Hz
Test Power Supply
No.
Frequency
MHz
Reading Level
dBµV
1
2
3
4
5
6
7
8
9
10
11
12
0.1768
0.1768
0.2589
0.2589
1.1321
1.1321
5.4868
5.4868
13.8807
13.8807
20.5993
★20.5993
35.48
31.56
30.53
22.38
24.61
22.67
21.40
13.52
28.05
20.74
36.58
27.47
Line
Factor Measurement
dB
dBµV
Limit
dBµV
9.67
9.67
9.67
9.67
9.68
9.68
9.73
9.73
9.97
9.97
10.30
10.30
79.00
66.00
79.00
66.00
73.00
60.00
73.00
60.00
73.00
60.00
73.00
60.00
45.15
41.23
40.20
32.05
34.29
32.35
31.13
23.25
38.02
30.71
46.88
37.77
Over Limit
Detector
dB
-33.85
-24.77
-38.80
-33.95
-38.71
-27.65
-41.87
-36.75
-34.98
-29.29
-26.12
-22.23
Remarks :
1.
2.
3.
4.
5.
6.
All readings are Quasi-peak and Average values.
Measurement = Reading + Factor (Could have ±0.01 tolerance due to computer automatically round off calculation).
Over Limit (Margin Value)=Measurement level-Limit value.
Factor = L.I.S.N. insertion loss + cable loss
“ ★ ” means that this data is the worse case measurement level.
The measurement uncertainty is 3.6 dB.
Line
Remark:
1. The “Limit” in right-up corner in above diagram refers to Quasi-peak ; “AVG” refers to the limit of Average.
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Listed Lab. of Commerce, FCC, VCCI.
Page 15 of 27
NVLAP Lab Code:200085-0
QP
AVG
QP
AVG
QP
AVG
QP
AVG
QP
AVG
QP
AVG
GESTEK Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
Tel:886-2-2603-5321 Fax:886-2-2603-5325
Date of Test
December 19, 2007
Temperature
26 ℃
60 %
EUT
Server
Humidity
Test Mode
Mode 5
Display Pattern
AC 100V/50Hz
Test Power Supply
No.
1
2
3
4
5
6
7
8
9
10
11
12
Frequency
MHz
0.1747
0.1747
0.2630
0.2630
0.3788
0.3788
0.5242
★0.5242
14.0548
14.0548
21.3001
21.3001
H Pattern
Reading Level
dBµV
36.31
33.12
31.75
25.95
28.51
18.13
29.23
28.35
25.19
17.70
34.53
24.31
Neutral
Factor Measurement
dB
dBµV
9.67
45.98
9.67
42.79
9.67
41.42
9.67
35.62
9.68
38.19
9.68
27.81
9.68
38.91
9.68
38.03
9.99
35.18
9.99
27.69
10.23
44.76
10.23
34.54
Limit
dBµV
79.00
66.00
79.00
66.00
79.00
66.00
73.00
60.00
73.00
60.00
73.00
60.00
Over Limit
Detector
dB
-33.02
QP
-23.21
AVG
-37.58
QP
-30.38
AVG
-40.81
QP
-38.19
AVG
-34.09
QP
-21.97
AVG
-37.82
QP
-32.31
AVG
-28.24
QP
-25.46
AVG
Remarks :
1.
2.
3.
4.
5.
6.
All readings are Quasi-peak and Average values.
Measurement = Reading + Factor (Could have ±0.01 tolerance due to computer automatically round off calculation).
Over Limit (Margin Value)=Measurement level-Limit value.
Factor = L.I.S.N. insertion loss + cable loss
“ ★ ” means that this data is the worse case measurement level.
The measurement uncertainty is 3.6 dB.
Neutral
Remark:
1. The “Limit” in right-up corner in above diagram refers to Quasi-peak ; “AVG” refers to the limit of Average.
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Listed Lab. of Commerce, FCC, VCCI.
Page 16 of 27
NVLAP Lab Code:200085-0
GESTEK Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
Tel:886-2-2603-5321 Fax:886-2-2603-5325
5.
RADIATION EMISSION DATA
5.1 TEST EQUIPMENT
The following test equipments are used during the radiated emission tests:
Item
Instrument
Manufacturer
Model
Serial No.
Next Cal. Date
1
Test Receiver
R&S
ESVS30
829007/014
2008.01.18
2
Spectrum Analyzer
HP
E4407B
US39240339
2008.08.06
3
Pre-Amplifier
HP
8447D
2944A08272
2008.09.09
4
BILOG Antenna
SCHAFFNER
CBL6112B
2620
2008.11.22
5
CABLE
GTK
N/A
GTK-E-A316-01
2008.11.06
6
Open Site
GTK
N/A
B1
2008.11.18
5.2 OPEN TEST SITE SETUP DIAGRAM
Note: This is a reprehensive setup diagram for Table-top EUT.
For Floor-standing EUT, the table will be removed with all others setup condition remain the same.
10m
FRP Dome
Broadband or
Dipole Antenna
Antenna height
can be moved
from 1m to 4m;
Antenna and
turntable distance
10m
NonConductive
Table
Load
EUT
80cm
Test
Receiver
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Listed Lab. of Commerce, FCC, VCCI.
1m to 4m
Antenna Mast
Metal Full Soldered Ground Plane
Page 17 of 27
NVLAP Lab Code:200085-0
TO controller
To Receiver
GESTEK Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
Tel:886-2-2603-5321 Fax:886-2-2603-5325
5.3 RADIATED EMISSION LIMIT
Class A Limit
Frequency
Distance
Field Strength
MHz
Meter
dB(µV/m)
30 to 230
10
40
230 to 1000
10
47
Remark : 1. The tighter limit shall apply at the edge between two frequency bands.
2. Distance refers to the distance in meters between the measuring instrument antenna and the closed point of
any part of the device or system.
5.4 EUT CONFIGURATION
The equipment which is listed 3.4. are installed on Radiated Emission Test to meet the
Commission requirement and operating in a manner which tends to maximize its emission
characteristics in a normal application.
The device under test, installed in a representative system as described in section 5.2., was
placed on a non-conductive table whose total height equaled 80 cm. This table can be rotated
360 degree. The measurement antenna was mounted to a non-conductive mast capable of
moving the antenna vertically. Antenna height was varied from 1 meter to 4 meters and the
system under test was rotated from 0 degree through 360 degrees relative to the antenna
position and polarization (Horizontal and Vertical). Also the I/O cable position was investigated
to find the maximum emission condition.
5.5 OPERATING CONDITIONS OF THE EUT
Same as section 4.6.
5.6 RADIATED EMISSION DATA
The measurement range of radiated emission, which is from 30 MHz to 1 GHz, was investigated.
All readings are quasi-peak values with a resolution Bandwidth of 120 KHz. The initial step in
collecting radiated emission data is a spectrum analyzer peak scans of the measurement range
for all the test modes and then use test receiver for final measurement. Then the worst modes
were reported the following data pages.
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Listed Lab. of Commerce, FCC, VCCI.
Page 18 of 27
NVLAP Lab Code:200085-0
GESTEK Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
Tel:886-2-2603-5321 Fax:886-2-2603-5325
5.7 RADIATED EMISSIONS MEASUREMENT RESULTS
Date of Test
EUT
Working Cond.
Antenna distance
Test Power Supply
No.
1
2
3
4
5
6
7
8
9
10
11
12
Frequency
MHz
129.6269
140.4372
160.9100
203.3982
240.0325
384.0017
398.2269
480.0437
600.1261
★674.9944
799.7189
965.0271
December 18, 2007
Server
Mode 5
10m at Horizontal
AC 100V/50Hz
Reading Level
dBµV
33.60
31.65
32.38
33.21
41.00
41.56
33.41
37.68
33.60
43.90
31.60
37.20
Factor
dB
-12.47
-12.78
-13.87
-13.57
-10.74
-6.52
-6.14
-4.74
-2.58
-1.49
0.18
2.56
Temperature
Humidity
Display Pattern
Frequency Range
Measurement
dBµV/m
21.13
18.87
18.51
19.64
30.26
35.04
27.27
32.94
31.02
42.41
31.78
39.76
Limit
dBµV/m
40.00
40.00
40.00
40.00
47.00
47.00
47.00
47.00
47.00
47.00
47.00
47.00
26 deg/C
60 %RH
H Pattern
30-1000MHz
Over Limit
dB
-18.87
-21.13
-21.49
-20.36
-16.74
-11.96
-19.73
-14.06
-15.98
-4.59
-15.22
-7.24
Detector
QP
QP
QP
QP
QP
QP
QP
QP
QP
QP
QP
QP
Remarks:
1.
2.
3.
4.
5.
6.
All Readings below 1GHz are Quasi-Peak.
Measurement = Reading + Factor (Could have ±0.01 tolerance due to computer automatically round off calculation).
Over Limit (Margin Value)=Measurement level-Limit value.
Factor = antenna factor + cable loss – amplifier gain.
“ ★ ” means that this data is the worse case measurement level.
The measurement uncertainty is 5.1 dB.
Remark:
1. The “Limit” in right-up corner in above diagram refers to Quasi-peak ; “Margin” refers to the data under 6dB.
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Listed Lab. of Commerce, FCC, VCCI.
Page 19 of 27
NVLAP Lab Code:200085-0
GESTEK Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
Tel:886-2-2603-5321 Fax:886-2-2603-5325
Date of Test
EUT
Working Cond.
Antenna distance
Test Power Supply
No.
1
2
3
4
5
6
7
8
9
10
11
12
Frequency
MHz
129.6263
140.4250
★160.0027
169.9029
202.8453
250.0172
384.0003
480.0431
600.1277
674.9952
720.0039
750.0491
December 18, 2007
Server
Mode 5
10m at Vertical
AC 100V/50Hz
Reading Level
dBµV
38.84
40.01
41.50
40.01
34.65
33.58
32.87
34.70
30.45
36.05
29.45
27.98
Factor
dB
-12.47
-12.77
-13.85
-14.04
-13.61
-9.98
-6.52
-4.74
-2.58
-1.49
-0.86
-0.47
Temperature
Humidity
Display Pattern
Frequency Range
Measurement
dBµV/m
26.37
27.24
27.65
25.97
21.04
23.60
26.35
29.96
27.87
34.56
28.59
27.51
Limit
dBµV/m
40.00
40.00
40.00
40.00
40.00
47.00
47.00
47.00
47.00
47.00
47.00
47.00
26 deg/C
60 %RH
H Pattern
30-1000MHz
Over Limit
dB
-13.63
-12.76
-12.35
-14.03
-18.96
-23.40
-20.65
-17.04
-19.13
-12.44
-18.41
-19.49
Detector
QP
QP
QP
QP
QP
QP
QP
QP
QP
QP
QP
QP
Remarks:
1.
2.
3.
4.
5.
6.
All Readings below 1GHz are Quasi-Peak.
Measurement = Reading + Factor (Could have ±0.01 tolerance due to computer automatically round off calculation).
Over Limit (Margin Value)=Measurement level-Limit value.
Factor = antenna factor + cable loss – amplifier gain.
“ ★ ” means that this data is the worse case measurement level.
The measurement uncertainty is 5.1 dB.
Remark:
1. The “Limit” in right-up corner in above diagram refers to Quasi-peak ; “Margin” refers to the data under 6dB.
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Listed Lab. of Commerce, FCC, VCCI.
Page 20 of 27
NVLAP Lab Code:200085-0
GESTEK Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
Tel:886-2-2603-5321 Fax:886-2-2603-5325
6.
PHOTOGRAPHS FOR TEST
6.1 TEST PHOTOGRAPHS FOR CONDUCTION EMISSION
Mode 5
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Listed Lab. of Commerce, FCC, VCCI.
Page 21 of 27
NVLAP Lab Code:200085-0
GESTEK Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
Tel:886-2-2603-5321 Fax:886-2-2603-5325
6.2 TEST PHOTOGRAPHS FOR RADIATED EMISSION
Mode 5
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Listed Lab. of Commerce, FCC, VCCI.
Page 22 of 27
NVLAP Lab Code:200085-0
GESTEK Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
Tel:886-2-2603-5321 Fax:886-2-2603-5325
7.
PHOTOGRAPHS FOR PRODUCT
1.
2.
Front View Of Server (EUT).
Back View Of Server(EUT).
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Listed Lab. of Commerce, FCC, VCCI.
Page 23 of 27
NVLAP Lab Code:200085-0
GESTEK Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
Tel:886-2-2603-5321 Fax:886-2-2603-5325
3.
Back View Of Server(EUT).
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Listed Lab. of Commerce, FCC, VCCI.
Page 24 of 27
NVLAP Lab Code:200085-0
GESTEK Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
Tel:886-2-2603-5321 Fax:886-2-2603-5325
8.
EMI/EMS REDUCTION METHOD DURING COMPLIANCE TESTING
No. Component Name
Manufacturer
Standards
Quantity
Position
1
gasket
laird
158*33*3 mm
1
I/O GASKET
2
springiness metal
Changguchuan
8.5*4.2*2.8 mm
1
HDD TRAY
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Listed Lab. of Commerce, FCC, VCCI.
Page 25 of 27
NVLAP Lab Code:200085-0
GESTEK Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
Tel:886-2-2603-5321 Fax:886-2-2603-5325
Appendix A
Circuit (Block) Diagram
(Shall be added by Applicant)
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Listed Lab. of Commerce, FCC, VCCI.
Page 26 of 27
NVLAP Lab Code:200085-0
GESTEK Lab
Report No: 0712034V-01
N0 3, Pau-Tou-Tsuo Valley, Chia-Pau Tsuen, Lin Kou Hsiang, Taipei County, Taiwan, R.O.C.
Tel:886-2-2603-5321 Fax:886-2-2603-5325
Appendix B
User Manual
(Shall be added by Applicant)
Accredited Lab. Of BSMI, NEMKO, NVLAP.
Listed Lab. of Commerce, FCC, VCCI.
Page 27 of 27
NVLAP Lab Code:200085-0