MGE Galaxy 5000
“A New Measure of Performance”
MGE Galaxy Series UPS 40 / 50 / 60 / 80 / 100 / 130 kVA
1 Multi-language user friendly display
with mimic diagram
1
2 IGBT rectifier / inverter
3 Four internal communication ports
4 Internal maintenance bypass
2
3
4
5
5 Easy access - quick cable connections
MGE Galaxy 5000
40/50/60/80/100/130 kVA
A new measure of performance
High power quality
Reduced total cost of ownership
High Power Availability
The Galaxy 5000 supplies clean, stable
power to sensitive loads ensuring:
The Galaxy 5000 is designed to minimize
infrastructure costs
The Galaxy 5000 is designed for
365 / 24 /7 operation
◗ Critical Power Protection
◗ Optimum performance
◗ Small footprint
◗ Low Input current total harmonic
distortion avoiding oversized cabling,
circuit breakers, and generator set
◗ Fault tolerance with built-in 100% rated
bypass static switch
◗ Extended life
Advanced architecture
◗ On-line double conversion
◗ DSP PWM control with variable
pulse width and frequency
◗ Input Power Factor Correction
◗ IGBT Six-pack technology
◗ Low output voltage total
harmonic distortion
Safe and Easy to Use
User Friendly Display
◗ Large, high definition display
(4.75 x 3.6 inches, 320 x 240 pixels)
◗ Animated mimic display
◗ Redundant components and cooling for
higher reliability
◗ High overload capacity to improve down
stream circuit discrimination
◗ Extended battery run times
◗ Integrated battery management system
◗ 2500 events log
◗ Remote power supervision compatible
with a wide range of building and
network management systems
Design Benefits
Data Center and Industrial Grade Power Protection
Power Module
Dual Input
Redundant Components
Premium Line-Up and Match
External Battery Enclosure
◗ Provides flexible, scalable
power capacity. Includes a fully
rated inverter for providing
more real power.
◗ Back-up for the Main Intelligence
Module provides increased
availability
Built-in Static Bypass Switch
◗ Enables the UPS to transfer the load
to utility power, without interruption,
in the event of heavy overload or fault
◗ Allows for connection to two
seperate input sources for
increased availability
◗ Up to four (4) enclosures can
be connected to the UPS for
extended run times
Line-up and Match
Auxiliary Gear
◗
◗
◗
◗
Voltage Transformation
Bypass
Top/Bottom Entry
Distribution
MGE Galaxy 5000
130 kVA / 117 kW
480V in 208V out I 3CB MBC I 208V / 120V Distribution
Features
Parallel up to Six Modules
Parallel Features
◗ Parallel up
p to 6 modules with
System Bypass Cabinet (SBC)
◗ Parallel for capacity
>1+0, 2+0, 3+0, 4+0, 5+0
◗ Parallel for redundancy
>1+1, 2+1, 3+1, 4+1, 5+1
◗ Parallel up to 2 modules without a
System Bypass Cabinet
>1+1 Redundancy
◗ 480V Only
◗ Parallel System Bypass Cabinet (SBC)
>80/160/320/520kVA
>2CB
>Secondary UPS Isolation (up to 6 breakers)
>Powerlogic PM800 Meter
◗ Field Upgrade Kits (Single to Parallel)
◗ Remote Alarm Status Panel
MGE Galaxy 5000
Flexible & Upgradeable
◗ Scalable Power Levels
◗ Parallel up to six modules for higher capacity
or redundancy
◗ Add modules as power needs grow
◗ Meet the future needs of you operation
◗ Easy integration with networking and
monitoring systems
◗ A choice of backup times from 8 minutes to 4 hours
◗ Field Upgradeable Single to Parallel
Standard Features
◗ On-line double conversion architecture
◗ High Power Density Design
◗ Input Power Factor Correction
◗ IGBT Rectifier / Inverter
◗ Fault Tolerant Architecture
◗ Power Surge Stabilization System
◗ Input Distortion Management
◗ Internal Maintenance Bypass
◗ Life Cycle Monitoring
◗ Step Load Voltage Stabilization
◗ Intelligent Battery Management System
◗ 100% Rated Static Bypass
◗ Dry Contact Board
◗ Bottom Entry
◗ Dual Input
◗ 4 Communication Slots
◗ User Friendly Display with 2500 event logging
– Multilanguage
– Mimic Diagram
– LED Overview
◗ Soft start, walk-in charger and inrush current limit for
compatibility with generator set
◗ Remote Emergency Power Off
◗ Casters with stabilizing legs
Options
◗ Input/Output Isolation transformers
– 208V/220V/480V/600V
◗ Input/Output Auto transformers
– 208V/220V/600V
◗ Singlee Input
◗ Matching External Maintenance Bypass
◗ Matching VRLA Battery Cabinets
◗ Adjacent or Remote Cabinets
◗ Distribution
– Panel board
– Sub Main Breakers
◗ Parallel System Bypass Cabinets
– 80/160/320/520kVA
– 2CB
– UPS Isolation Breakers
– PM800 Meter
◗ Communication cards
– RS232
– RS485
– Dry Contact
– Network management Card
◗ Top Entry Cabinets
◗ 65kAIC rating
◗ Synchronization module (CBS)
◗ Seismic Brackets
◗ Remote Alarm Status Panel
◗ Remote Summary Alarm Panel
◗ Wall Mount Battery Disconnect
◗ Spare Part Kits
– Level A, B, C, D
132 Fairgrounds Road • West Kingston, RI 02892
Technical
TechnicalSpecifi
Specifications
cations
UPS Rating kVA/kW
40/36
50/45
60/54
80/72
100/90
130/117
Input Voltage
Frequency
Power Factor
THDI
Efficiency (Full Load at Tech Rating)
Output Voltage
Frequency
Voltage Regulation
Voltage Transient Response
Voltage Recovery Time
Voltage Distortion
Inverter Overload
Bypass Overload
Heat Rejection (BTU) @480V
Environmental
Operating Temperature
Non Operating Temperature
Dimensions and Weights
UPS 40 to 80kVA
UPS 100 to 130kVA
Matching Maintenance Bypass
Transformer Cabinet
Distribution Cabinet
Top Entry Cabinet
Battery Cabinet
Battery Cabinet
Battery Cabinet
Parallel System Bypass Cabinet (480V Only
Only)
80kVA / 160kVA
320kVA / 520kVA
Distribution
Standards
480V Core, 3 Wire + G (220V,208V, 600V w/ Aux Transfomer 4 Wire + G)
60Hz +/- 5%
<0.99
<5%
Up to 94%
480V Core, 3 Wire + G (220V,208V, 600V w/ Aux Transfomer 4 Wire + G)
60Hz
+/- 1.0% balance load , +/- 2.5% unbalanced load
+/- 5% for 100% step load, +/-1% for loss or return of AC input
Within 1% of nominal within 1 cycle
<1% L-L and L-N for non-linear loads (<2% max)
150% for 1 min, 125% for 10min
10x nominal current for 1 cycle
9248
11560
13872
18496
19607
25489
UPS 0-40C (32F to 104F), Battery 25C(77F)
-20C to +45C ( -4F to 113F)
28” W x 33.42” D x 75” H (882 lbs)
28” W x 33.42” D x 75” H (1146 lbs)
28” W x 33.42” D x 75” H
28” W x 33.42” D x 75” H
42” W x 33.42” D x 75” H
14” W x 33.42” D x 75” H
26” W x 33.42” D x 75” H
32” W x 33.42” D x 75” H
48” W x 33.42” D x 75” H
28” or 42” W x 33.42” D x 75” H
28” W x 33.42” D x 75” H
42” W x 33.42” D x 75” H
42” W x 33.42” D x 75” H
ISO 9001, UL 1778, cUL, UL924, FCC Part 15, Subpart J, Class A, NEMA PE 1,
NEMA 250, NFPA 70, IEC 1000 (801) level 4, OSHA
Due to continuing improvements, specifications are subject to change without notice. All data based on technical ratings–commercial rating may vary.
GX 5K • revision 200 • effective August 2008