550.50-TG1Y (600)
®
TECHNICAL SPECIFICATIONS
SPLIT-SYSTEM
CONDENSING UNITS
“HRE” Series
Models H*RE024 thru H*RE060
Nominal Capacity: 24 thru 60 MBH
Nominal Efficiency: 14.00 SEER
DESCRIPTION
The HRE Series condensing unit is the outdoor part of a versatile
system of air conditioning. It is designed to be custom-matched
with one of our complete line of evaporator sections, each designed to serve a specific function. Matching Air Handlers are
available for upflow, downflow or horizontal applications to provide
a complete system. Electric heaters are available if required.
Add-On coils are available for use with upflow, downflow or
horizontal furnaces.
LOWER INSTALLED COST - Installation time and costs are
reduced by easy power and control wiring connections. Discharge
line heat exchanger knockouts are provided, if required. Available
in sweat connect models only. The unit contains enough refrigerant for matching indoor coils and 15 feet of interconnecting piping.
The small base dimension means less space is required on the
ground or roof. Start-assist components included as standard
where TXV is required.
FEATURES
TOP DISCHARGE - The warm air from the top mounted fan is
blown up away from the structure and any landscaping. This
allows compact location on multi-unit applications.
QUALITY CONDENSER COILS - The coil is constructed of
copper tube and hardened black coated aluminum fins for durability
and long lasting efficient operation. The decorative 2" x 4" grille
backed by the black coated fins, enhances appearance and
protects the unit.
PROTECTED COMPRESSOR - The compressor is internally
protected against high pressure and temperature. This is
accomplished by the simultaneous operation of a high pressure
relief valve and a temperature sensor which protects the compressor if undesirable operating conditions occur. A liquid line
filter-drier further protects the compressor.
DURABLE FINISH - Cabinet is made of pre-painted steel. The
pre-treated flat galvanized steel provides a better paint to steel
bond, which resists corrosion and rust creep. Special primer
formulas and glossy earth tone finish insure less fading when
exposed to sunlight.
LOW OPERATING SOUND LEVEL - The upward air flow carries
the normal operating noise up away from the living area. The rigid
top panel effectively isolates any motor sound. Isolator mounted
compressor and the rippled fins of the condenser coil muffle the
normal fan motor and compressor operating sounds.
LOW MAINTENANCE - Long life permanently lubricated motorbearings need no annual servicing.
EASY SERVICE ACCESS - Fully exposed refrigerant connections
and a single panel covering the electrical controls and the molex
plug in the control box connecting the condenser fan, make for
easy servicing of the unit.
SECURED SERVICE VALVES - Secured re-usable service valves
are provided on both the liquid and vapor sweat connections for ease
of evacuating and charging.
FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE
550.50-TG1Y
COOLING CAPACITY - With Air Handler Coils
UNIT
MODEL*
AIR HANDLER
BLOWER
HEAT
W
COIL2
MODEL
COOLING
RATED
CFM
NET MBH
TOTAL
SENS.
KW
SEER
SEER/
TXV1
EER
H*RE \ N*AH - SINGLE PHASE
H1RE024
N1AHB08
5,8,10,15,18
17
H1RE030
N1AHB12
5,8,10,15,18
17
H1RE036
N1AHB12
N1AHB16
5,8,10,15,18
5,8,10,15,18
17
17
N1AHC16
5,8,10,15,20
21
N1AHD14
5,8,10,15
24
H2RE048
N1AHD20
5,8,10,15,20,25,30
24
H1RE060
N1AHD20
5,8,10,15,20,25,30
24
H2RE042
G2FD030S17
G2FD030S17
G2FD036S17
G2FD036S17
G2FD046S17
G2FD042S21
G2FD048S21
G2FD060S24
G2FD060S24
G2FD061H24
G2FD060S24
G2FD061H24
850
1025
1025
1200
1250
1400
1450
1400
1650
1650
1825
1850
24.8
28.4
28.8
34.0
35.0
39.0
39.5
39.5
46.5
47.0
55.5
56.5
17.9
20.4
20.7
24.5
25.2
28.2
28.9
29.2
33.9
34.3
40.8
43.0
2.00
2.40
2.40
2.90
2.90
3.44
3.41
3.43
3.95
3.95
4.63
4.67
-------------
13.85
13.00
13.10
13.35
14.00
13.25
13.50
14.00
13.85
14.00
13.50
13.50
12.20
11.65
11.80
11.80
12.20
11.35
11.60
11.50
11.80
11.90
12.00
12.10
G2FD036S17
G2FD046S17
G2FD036S17
G2FD046S17
G2FD046S17
G2FD048S21
G2FD048S21
G2FD060S24
G2FD048S21
G2FD060S24
G2FD060S24
G2FD061S24
825
850
1025
1050
1225
1250
1425
1600
1625
1650
1825
1850
25.6
26.2
29.6
30.0
35.2
39.5
40.5
41.5
46.5
47.5
57.0
58.0
18.4
18.9
21.3
21.6
25.3
25.9
29.8
30.8
34.1
34.8
42.8
44.9
1.80
1.90
2.20
2.20
2.80
2.60
3.24
3.14
3.68
3.59
4.16
4.28
-------------
15.00
15.50
15.00
15.35
14.00
15.00
14.50
15.50
15.00
15.50
15.25
15.25
13.85
14.15
13.30
13.60
12.40
13.60
12.50
13.20
12.65
13.25
13.70
13.55
---
850
1035
1250
1250
1400
1400
1650
1600
1825
1850
25.0
29.8
34.4
34.4
40.5
39.5
47.5
46.0
55.0
57.0
18.0
21.5
24.8
24.8
29.8
28.9
34.9
33.4
41.4
42.8
2.03
2.40
2.84
2.89
3.39
3.50
3.60
4.09
4.74
4.22
-----------
13.80
13.85
13.50
13.30
14.00
13.25
15.50
13.00
13.00
15.25
12.30
12.40
12.10
11.90
11.95
11.30
13.20
11.25
11.60
13.50
H*RE / N*VS - VARIABLE SPEED
H1RE024
N1VSB12
5,8,10,15,18
17
H1RE030
N1VSB12
5,8,10,15,18
17
N1VSB12
N1VSC16
N1VSC16
N1VSD20
N1VSC16
N1VSD20
5,8,10,15,18
5,8,10,15,20
5,8,10,15,20
5,8,10,15,20
5,8,10,15,20
5,8,10,15,20,25,30
17
21
21
21
21
24
N1VSD20
5,8,10,15,20, 25,30
24
F2RP/FP036
F2RP/FP036
F2RP/FP036
F2RP/FP042
F2FP045
F2FP048
F2FV060
F2FP060
F2FP060
F2FV060
5,8,10,15
5,8,10,15
5,8,10,15
5,8,10,15
5,8,10,15
10,15,20,25
10,15,20,25
10,15,20,25
10,15,20,25
10,15,20,25
21
18
21
21
24
24
24
24
24
24
H1RE036
H2RE042
H2RE048
H1RE060
H*RE
H1RE024
H1RE030
H1RE036
H2RE042
H2RE048
H1RE060
--------
Certified in accordance with the Unitary Small Equipment certification program, which is based on ARI Standard 210/240.
Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.
KW includes compressor, outdoor fan and indoor blower motor watts. Add-on coils include 365 watts/1000 CFM for blower motor.
EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at a 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions.
SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power
input in watt-hours during the same period.
1
1TV0700 Series Thermal Expansion Valve kit required on indoor coil to obtain system performance. (Start assist components included, except 8 models with scroll
compressors.)
4
To meet R=4.2 insulation requirements, substitute F2FP for F2RP models.
All ratings remain the same.
3
P3HU and P3UR furnaces and FRP Air Handlers have B.O.D. standard. (All Ratings include B.O.D.)
* All models are single phase, unless noted otherwise.
"--" Field transition may be required.
2
Refer to coil installation guide for proper coil application.
2
Unitary Products Group
550.50-TG1Y
COOLING CAPACITY- with downflow and horizontal upflow furnace and coils
UNIT
MODEL*
H1RE024
H1RE030
H1RE036
H2RE042
H2RE048
H1RE060
FURNACE**
NOMINAL
W
AIRFLOW
17,21
17
800
14
1000
17
1200
21
17,21
14,17
1000
21,24
1200
17
1400
17,21
-21,24
21
21,24
1200
17
1400
21
1600
17
-21
21,24
21
1400
24
1600
17
2000
21,24
24
24
21,24
21,24
21,24
1600
24
2000
24
24
21,24
24
1825
24
2000
---
COIL2
MODEL
G1UA036S17,21
G2FD030S17
G2FD035S14
G2FD036S17
G2FD036S21
G1UA036S17,21
G2FD030S17
G1UA048S21,24
G2FD036S17
G2FD036S21
G1NF060SOF
G1UA048S21,24
G2FD042S21
G2FD048S21,24
G2FD046S17
G2FD036S21
G2FD036S17
G1NF060SOF
G2FD042S21
G1UA048S21,24
G1UA060S21
G1UA060S24
G2FD046S17
G2FD048S21,24
G2FD060S24
G1NF060SOF
G2FD048S21,24
G1UA048S21,24
G1UA060S21,24
G2FD060S24
G2FD061H24
G1NF060SOF
G1UA060S21,24
G2FD060S24
G2FD061H24
G1NF060SOF
G1HD060S
COOLING
RATED
CFM
800
800
800
850
850
1025
1000
1025
1025
1025
1025
1250
1225
1250
1225
1225
1225
1225
1400
1425
1450
1450
1400
1425
1450
1425
1600
1600
1620
1620
1650
1625
1800
1800
1950
1800
1800
NET MBH
TOTAL
SENS.
17.9
24.8
17.9
24.8
17.9
24.8
18.1
25.2
18.1
25.2
20.5
28.4
20.5
28.4
21.6
30.0
20.7
28.8
21.0
28.8
21.5
29.0
25.3
35.2
28.4
34.8
25.7
35.2
25.6
35.0
24.8
34.0
24.5
34.0
25.6
34.6
28.2
39.0
28.4
39.0
28.4
40.5
29.6
40.5
28.6
39.0
28.9
39.5
28.4
40.5
29.5
40.5
33.2
45.5
32.6
45.0
33.9
46.5
33.9
46.5
34.3
47.0
32.8
46.5
40.8
55.5
40.8
55.5
43.0
56.5
41.1
55.5
40.0
54.5
KW
SEER
2.03
2.03
2.03
2.04
2.02
2.44
2.44
2.42
2.44
2.38
2.32
2.86
2.88
2.83
2.87
2.82
2.88
2.88
3.44
3.41
3.48
3.43
3.41
3.41
3.43
3.39
3.92
3.91
3.94
3.94
3.95
3.92
4.63
4.63
4.67
4.59
4.58
--------------------------------------
SEER/
TXV
13.85
13.85
13.85
14.00
14.00
13.00
13.00
14.00
13.10
13.10
14.00
14.00
13.70
14.00
14.00
13.35
13.35
14.00
13.25
13.50
14.00
14.00
13.50
13.50
14.00
14.00
13.50
13.40
13.85
13.85
14.00
14.00
13.50
13.50
13.50
13.50
13.00
EER
12.20
12.20
12.20
12.35
12.45
11.65
11.65
12.40
11.80
12.10
12.50
12.30
12.10
12.45
12.20
12.05
11.80
12.00
11.35
11.45
11.35
11.80
11.45
11.60
11.80
11.75
11.60
11.50
11.80
11.80
11.90
11.85
12.00
12.00
12.10
12.10
11.90
** Refer to Quick Selection Chart for specific Furnace matchup
* Requires 2FD fan time delay
Unitary Products Group
3
550.50-TG1Y
COOLING PERFORMANCE
SUCT. T/P
@ COMPR.
MODEL*
H1RE024
H1RE030
H1RE036
AIR TEMP ON CONDENSER
75°F
95°F
115°F
MODEL
AIR TEMP ON CONDENSER
SUCT. T/P
@ COMPR.
75°F
95°F
115°F
TEMP. PSIG
MBH
KW
MBH
KW MBH
KW
TEMP.
PSIG
MBH
KW
MBH
KW MBH
KW
35° F
61.5
22.9
1.42
19.4 1.63 15.9
1.82
35° F
61.5
36.1
2.31
31.7 2.94 27.5
3.81
40° F
68.5
25.3
1.45
21.6 1.67 18.0
1.90
40° F
68.5
39.3
2.33
34.6 2.95 30.1
3.81
45° F
76.0
28.0
1.47
24.0 1.72 20.1
1.97
45° F
76.0
42.6
2.35
37.7 2.97 32.9
3.83
50° F
84.0
30.7
1.49
26.5 1.76 22.3
2.04
50° F
84.0
46.1
2.39
40.9 3.00 35.8
3.84
35° F
61.5
26.5
1.76
22.9 1.99 19.2
2.11
35° F
61.5
43.2
2.64
38.2 3.31 33.2
4.22
40° F
68.5
29.4
1.77
25.6 2.03 21.7
2.19
40° F
68.5
47.0
2.66
41.6 3.34 36.4
4.24
45° F
76.0
32.5
1.77
28.4 2.07 24.3
2.27
45° F
76.0
50.9
2.69
45.2 3.37 39.7
4.28
50° F
84.0
35.8
1.76
31.4 2.10 27.0
2.33
50° F
84.0
54.9
2.72
48.9 3.39 43.0
4.31
35° F
61.5
32.0
1.96
29.2 2.44 26.3
3.10
35° F
61.5
52.4
3.09
46.8 3.83 41.2
4.82
40° F
68.5
34.8
1.97
31.9 2.45 28.8
3.11
40° F
68.5
56.8
3.11
51.0 3.87 45.1
4.86
45° F
76.0
37.7
1.99
34.7 2.47 31.5
3.12
45° F
76.0
61.4
3.15
55.3 3.91 49.2
4.91
50° F
84.0
40.7
2.01
37.6 2.48 34.3
3.13
50° F
84.0
66.2
3.18
59.8 3.96 53.3
4.96
H2RE042
H2RE048
H1RE060
NOTES: 1. For condensing unit only. Does not include effect of evaporator motor power or heat.
2. Performance based on 15°F superheat and 15°F sub-cooling at condensing unit.
a. Increase capacity 1% for each 2°F increase in sub-cooling.
b. Decrease capacity 1% for each 2°F decrease in sub-cooling.
3. Sub-cooling in excess of 20°F may result in excessively high condensing temperature with air on condenser above 115°F.
Maximum recommended condensing temperature is 140°F.
SOUND RATINGS
UNIT MODEL
HRE
024
030
036
042
048
060
4
SOUND
RATINGS
BELS
76*
76*
76
76
76
76
CERTIFICATION APPLIES
ONLY WHEN THE COMPLETE SYSTEM IS
LISTED WITH ARI
Unitary Products Group
550.50-TG1Y
TYPICAL INSTALLATION - HRE024 THRU 048
6 0 " O V E R H E A D
C L E A R A N C E
1 8 " S E R V IC E
A C C E S S C L E A R A N C E
T H E R M O S T A T
W E A T H E R P R O O F
D IS C O N N E C T
S W IT C H
T O
F U R N A C E O R A IR H A N D L E R
T E R M IN A L B L O C K
N E C C L A S S 1 W IR IN G
N E C C L A S S 2 W IR IN G
1 0 " C L E A R A N C E
C O IL A R E A
T O
IN D O O R C O IL
N O T E : A L L O U T D O O R W IR IN G
B E W E A T H E R P R O O F
S E A L O P E N IN G (S ) W IT H P E R M A G U M
M U S T
O R E Q U IV A L E N T
C O N T R O L A C C E S S P A N E L
Unitary Products Group
5
550.50-TG1Y
TYPICAL FIELD WIRING
6
Unitary Products Group
550.50-TG1Y
ACCESSORIES
Refer to Price Manual for specific model numbers.
Compressor Blanket - Designed to further reduce the normal
operating sound.
Blower Time Delay - Available to increase efficiency when installed. Installs on indoor section and maintains blower for approximately one minute after cooling thermostat has been
satisfied.
Room Thermostats - One of the following thermostat may be
used with these systems.
2ET07700324 - Programmable electronic 1H/1C Manual
change over.
2TH07700124 - One Stage Heat / One Stage Cool, manual
changeover, non-programmable
TXV Kit - Must be used to obtain system performance. 1TV0700
Series TXV Kit. See Tabular Data insert for proper selection.
Unitary Products Group
7
MATCHING INDOOR COMPONENTS
Add-On Coils - For Furnace Application
G1NF
Outdoor
Furnace
Coil
G1UA
UPFLOW
G2FD*
MULTI-POSITION
(Upflow, Horizontal,
and Downflow)
G1HD
HORIZONTAL
*Available with factory installed horizontal drain pan.
Air Handlers - For Non-Furnace Application
F2RP/F2FP/F2FV
FAN COIL
UNITS
N1VS, N1AH
BLOWER
G2FD
COIL
UPFLOW
HORIZONTAL
Unitary Products Group
5005 York Drive, Norman, Oklahoma 73069
Subject to change without notice. Printed in U.S.A.
Copyright  by York International Corporation 2000. All Rights Reserved.
UPFLOW
DOWNFLOW
HORIZONTAL
Code: EBY,
550.50-TG1Y
Supersedes: 550.50-TG1Y (1298)