PRODUCT MODEL NUMBERS
WED94HEX, WED95HEX,
WED97HEX, WEDXXHEX
Electrical : This dryer requires a 3 or 4 wire, single phase, 120/240 volt, 60 Hz., AC only electrical supply
(or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate
30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended.
Connect to an individual branch circuit. Do not have a fuse in the neutral or grounding circuit.
Water (Steam models only) : The dryer must be connected to the cold water faucet using new inlet hoses. Do not use old hoses. Do not overtighten.
Damage to the coupling can result.
Exhaust venting : Exhaust your dryer to the outside.
4" (102 mm) diameter vent is required. Rigid or flexible metal exhaust vent must be used. Do not use plastic or metal foil vet. Exhaust hood must be at least
12" (305 mm) from the ground or any object that may be in the path of the exhaust.
Hood styles: A & B are recommended.
Electric Dryer Installation Instructions
OVERALL DIMENSIONS
Dryer dimensions
Front view:
27"
(686 mm)
Side view:
50 7 /
8
"
(1292 mm)
30 5 /
8
"
(728 mm)
38 1 /
8
"
(968 mm)
3 /
4
"*
(18 mm)
Back view:
6 1 /
2
"
(165 mm)
Left or right side exhaust
3 /
4
"*
(18 mm)
29 7 /
8
"*
(759 mm)
3 1 /
2
"*
(89 mm)
NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for exhaust vent with elbow. See “Venting Requirements.”
A B
A. Louvered hood
B. Box hood
C. Angled hood (acceptable)
C
The Vent system chart provides venting requirements that will help achieve best drying performance.
NOTE: Side and bottom exhaust installation have a 90° turn inside the dryer. To determine maximum exhaust length, add a 90° turn to the total number of elbows when referemcing the chart.
Number of
90° elbows
0
Vent system chart
Type of vent
Box/louvered hoods
Rigid metal 64 ft. (20 m)
Angled hoods
58 ft. (17.7 m)
3
4
1
2
Rigid metal
Rigid metal
54 ft. (16.5 m)
44 ft. (13.4 m)
Rigid metal
Rigid metal
35 ft. (10.7 m)
27 ft. (8.2 m)
48 ft. (14.6 m)
38 ft. (11.6 m)
29 ft. (8.8 m)
21 ft. (6.4 m)
Do not use vent runs longer than specified in vent length chart.
Determine the number of elbows you will need.
3 /
4
"*
(18 mm)
14 3 /
8
"
(365 mm)
6 1 /
8
"*
(156 mm)
Closet installation (dryer only):
* Approximate measurement
5"
(127 mm)
18" min.
(457 mm)
3"
(76 mm)
48 in.
2 min.
(310 cm 2 )
1"
(25 mm)
1"
(25 mm)
3"
(76 mm)
24 in.
2 min.
(155 cm 2 )
For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air ventilation openings are acceptable.
Select the route that will provide the straightest and most direct path outdoors.
Plan the installation to use the fewest number of elbows and turns.
Use the fewest 90° turns possible.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.