- Industrial & lab equipment
- Electrical equipment & supplies
- Power conditioning
- Power adapters & inverters
- SHENZHEN ENCOM ELECTRIC TECHNOLOGIES CO.
- EDS1300 series
- User manual
SHENZHEN ENCOM ELECTRIC TECHNOLOGIES CO. | EDS1300 series | User manual | enc inverter
Add to my manuals14 Pages
SHENZHEN ENCOM ELECTRIC TECHNOLOGIES CO. EDS1300 series is an intermediate frequency inverter that provides high-performance control for a wide range of applications. It features a compact design, easy-to-use interface, and a variety of advanced features that make it a great choice for industrial and commercial use. The EDS1300 series is available in a variety of power ratings and can be used with both single-phase and three-phase motors. Some of the key features of the EDS1300 series include:
*1000Hz carrier frequency, which reduces motor noise and vibration, and improves torque performance at low speeds.
advertisement
E N C I N V E RT E R
SHENZHEN ENCOM ELECTRIC TECHNOLOGIES CO.,LTD.
Http:www.enc.net.cn/en Email:[email protected]
Tel.:86755-26984485 Fax: 86755-26985120
Note: This Brochure is made and printed for the purpose of describing relevant information of the products only. Shenzhen Encom Electric
Technologies CO., LTD. reserves the right to make changes to the product(s) or information contained in this Brochure due to technical upgrade etc. without notice. Please contact us or the local agent before placing an order.
P
roduct
Selection Brochure
E N C I N V E RT E R
SHENZHEN ENCOM ELECTRIC TECHNOLOGIES CO.,LTD.
A
bout Encom
Company brief introduction
Founding Time: 2004
Company Cert: ISO9001:2008 quality management system approval
Main Item: Frequency Inverter /AC Drive /Variable Frequency Drive
Production Cert: CE approval
Number of Employees: 332
Number of R&D staffs: 50
Factory Size: 6800㎡ brand-new manufacture base
Annual capacity: 400 million
Honor of Encom: National innovation Fund
Shenzhen Hi-tech R&D subsidies
Business-beginning subsidies for student abroad
Shenzhen Software Association member
ISO9001:2008 Certificate
1: Shape of it is deformed by e+N+e, and it comes from the pronunciation of the first letter of “Encom”, stands for Encom.
2: Two gradient radians represent that
Encom is committed to the development of energy conversion technologies, upside means energy input , after transformed by
“N”(ENCOM),output through downside radian.
3: The outside part of the overall image is arc (curve), of soft beauty, represent that
Encom have a good attitude of friendly, s i n c e re a n d w i n - w i n t o w a r d p u b l i c relations group (customer and so on ), the middle part has sharply angular, which means that the internal of company have powerful core strength, rigorous work style, standardized management.
"ENC" meaning: it is the first three letters of Encom, the abbreviation of Shenzhen
Encom Electric Technologies CO., LTD.
www.encvfd.com
P roducts series
EDS-V300 current vector inverter (1 phase 220V 0.4~3.7KW, 3 phase 380V 0.75~55KW)
EDS580 series easy-fit cabinet inverter (3 phase 380V 0.75KW)
EDS780 series easy-fit single-board inverter (1 phase 220V 0.75KW)
EDS800 series mini universal inverter (1 phase 220V 0.2~1.5KW, 3 phase 380V 0.75-1.5KW)
EDS1000 series multi-function universal inverter (1 phase 220V 0.4~3.7KW, 3 phase 380V
0.75~55KW, 3 phase 690V 11~200KW)
EDS1100 specialized drawing machine inverter(3 phase 380V 1.5~55KW)
EDS1300 series intermediate frequency inverter
(1000Hz, 1 phase 220V 0.4~1.5KW, 3 phase 380V 0.75~37KW)
EDS2000 series high-performance universal inverter (3 phase 380V 75~ 400KW)
EDS2080 series bypass /variable frequency integrated energy save and control machine
(3 phase 380V 7.5KW~280KW)
EDS2800 series current vector control engineering inverter (including special function for injection molding machine, 3 phase 380V 11~75KW)
EDS2860 series special type with integrated energy save and control for injection molding machine (3 phase 380V 7.5~55KW)
EDS3000 series flux vector inverter
U
nique performance characteristic:
1. Adopt control unit which takes DSP as core to realize hi-speed and hi-performance
control to the system and to realize low-frequency hi-torque output;
2. Multiple I/O interfaces to fulfill special demands from every line;
3. Reasonable design of digital potentiometer and 3 classes menu;
4. Standard/optional RS485 communication interface;
5. Support local and remote keypad, extended distance can reach 1000 meters;
6. Keypad parameter copy function;
7. Password protection function;
8. Open product development platform, easy to customize.
E N C I N V E RT E R
EDS-V300 EDS580
EDS780
EDS800 EDS1000 EDS2000
EDS3000
T
ype Selection:
E D S 1 0 0 0 - 4 T 0 11 0 G / B
Code
B
C
D
E
Code
Accessories
Built -in brake unit
Built -in brake unit and brake resistance
W ith LCD display
W ith remote -control keypad
I nverter type
G
P
Constant torque general type
Type for blower and water pump
Code
Adaptable motor power (KW)
E D S 1 0 0 0
4000
Input volt.
T hree phase
S ingle phase
400 code
T
S
Volt. grade
220V
380V
690V code
2
4
7
High performance universal type
EDS2000
1 2
Parameter table of inverter power and adaptable motor
Type
Input voltage
Rated power
(KVA )
Rated output current
(A )
Adaptable motor
(KW )
Adaptable motor
(HP )
EDS**** -2S0002
EDS**** -2S0004
EDS**** 2S0007
EDS**** -2S0015
EDS**** -2S0022
1phase
220V ±15%
0.6
1.1
1.8
2.8
3.8
1.6
3
4.7
7.5
10
0.2
0.4
0.75
1.5
2.2
0.27
0.55
1
2
3
EDS**** 2S0037
EDS**** -4T0007
EDS**** -4T0015
EDS**** -4T0022
EDS**** -4T0037
EDS**** -4T0055
EDS**** -4T0075
5.6
1.5
2.4
3.3
5.6
8.6
11
17
2.3
3.7
5.0
8.5
13
17
3.7
0.75
1.5
2.2
3.7
5.5
7.5
5
3
5
1
2
7.5
10
EDS**** 4T0110
EDS**** -4T0150
17
21.7
25
33
11
15
15
20
EDS**** -4T0185 25.7
39 18.5
25
EDS**** -4T0220
EDS**** -4T0300
EDS**** -4T0370
EDS**** -4T0450
EDS**** -4T0550
EDS**** -4T0750
EDS**** -4T0900
EDS**** -4T1100
EDS**** -4T1320
EDS**** -4T1600
EDS**** -4T2000
EDS**** -4T2200
EDS**** -4T2500
EDS**** -4T2800
EDS**** -4T3150
EDS**** -4T3500
3phase
380V ± 15%
250
280
318
342
390
430
99
116
138
167
200
29.6
39.5
49.4
60
73.7
426
474
520
600
650
150
176
210
253
304
380
45
60
75
91
112
200
220
250
280
315
350
75
90
110
132
160
22
30
37
45
55
250
275
313
350
394
437
75
100
125
150
30
40
50
60
175
200
EDS**** -4T3750
EDS**** -4T4000
EDS**** -7T0110
EDS**** -7T0150
EDS**** -7T0185
EDS**** -7T0220
EDS**** -7T0300
EDS**** -7T0370
EDS**** 7T0450
447
493
17
21.7
25.7
29.6
39.5
49.4
60
680
750
15
18
22
28
35
45
52
375
400
11
15
18.5
22
30
37
45
469
500
15
20
25
30
40
50
60
EDS**** -7T0550
EDS**** -7T0750
EDS**** -7T0900
3phase 690V
±15%
73.7
99
116
63
86
98
55
75
90
75
100
125
EDS**** -7T1100
EDS**** -7T1320
138
167
121
150
110
132
150
175
EDS**** -7T1600 200
250
175
215
160
200
200
250
EDS**** -7T2000
Specification
EDS800/EDS1000/EDS2000/EDS2080/EDS2800/ EDS2860/ EDS-V300
Item Item description
Rated volt., frequency
Allowed work volt. range
Voltage
Frequency
Over loading capacity
3 phase 690V, 50 Hz/60Hz; 3 phase 380V, 50Hz/60Hz; single phase 220V, 50Hz/60Hz
: 320V~460V; single phase 220V: 200V~260V
690V grade: 0 -690V; 38 0V grade: 0 -380V; 200V grade: 0 - 220V
0Hz - 400Hz
G type: 150% of rated current for 1 minute 200% of rated current for 0.5s;
P type: 120% of rated current for 1 minute (for type of 3.7kw~132kw); 110% of rated current for 1 minute, 150% of rated current for 1 second (for type of above 160kw)
EDS2800/EDS2860 series: 150% of rated current for 3 minutes , 200% of rated current for 5 seconds
Control mode
EDS - V300 series: Speed sensorless current vector control
EDS2000 series: Optimal space voltage vector PWM control; EDS2800 /EDS2860 : simple current vector control
EDS1000 series: Speed sensorless slip vector control, open loop V/F control
EDS800 series: optimal space voltage vector SVPWM constant voltage frequency ratio V/F control
Speed regulation range
Automatic current limiting
1 :100
Start - up torque
150% of rating torque at 0.5
Hz for EDS - V300 series;
150% of rating torque at 3 Hz for EDS2000 series;
100% of rating torque at low frequency for EDS800 series;
150% of rating torque at 1 Hz for EDS1000 series;
130% of rating torque at 1 Hz for EDS2800/EDS2860 series .
Running speed stable state precision
Frequency precision
Analog setting
≤±0.5% of rating synchronous speed
Digital setting: max. frequency×±0.01%
; analog setting: max.
0.1% of max. frequency frequency×±0. 5%
Frequency resolution
Digital setting
Exterior pulse
Digital keyboard settings
Torque boost
0.01Hz (EDS2000/EDS800), if <100Hz: 0.01Hz; if ≥100Hz: 0.1Hz.
0.1% of max. frequency; EDS800/1000 series is 0.5% of max. frequency;.
0.01Hz(EDS2000)
Automatic torque boost , manual torque boost 0.1%~20.0%
Automatic torque boost , manual torque boost 0.1%~ 12 .0%
(EDS2000/EDS800);
(EDS1000).
V/F curve (volt. frequency characteristic)
Accelerating decelerating curve
Jog
DC brake
Set rating frequency randomly at range of 5~400Hz, can choose constant torque, degressive torque 1, degressive torque 2, degressive torque 3 and user defined V/F curve in total 5
3 kinds of modes: straight line accelerating decelerating, Scurve accelerating decelerating and automatic
Acce/Dece mode; 4 kinds of Acce/Dece time (unit of minute/second can be max.
is 6000 minutes.
o ptioned),
EDS1000 series has two modes: straight line accelerating decelerating, and S curve accelerating Decelerating; 7 kinds of accelerating decelerating time can be optioned ), max . is 6000 minutes.
(unit of minute/second brake
Power consumption brake
Multi section speed running
Interior PID controller
Automatic energy save running
Built-in or exterior braking resistance (EDS800 built-in braking unit, exterior braking resistance), details refer to manual.
Optional start-up and stop, action frequency 0~15Hz , action volt. 0~15% , action time 0~20.0 s
Jog frequency range : 0.50Hz~50.00Hz; jog accelerating decele rating time 0.1~60.0s can be set
Realized by interior PLC or control terminal
Be convenient to make closed loop system
Optimize V/F curve automatically based on the lo ad to realize power save running
Automatic volt. regulation (AVR) Can keep constant output volt. When power source voltage varies.
Limit running current automatically to avoid frequent over -current which will cause trip
3 4
Item
Running order specified channel
Item description
Keypad provision, control terminal provision, serial port provision
Running frequency specified channel
Digital provision, analog provision, impulse provision, serial port provision, combined provision, can be switched at any time by kinds of method
P ulse output channel
Impulse square wave signal output of 0~50KHz (for EDS1000/EDS800 it is 0~20KHz) can realize output of physical parameter such as setting frequency, output frequency and etc.
Analog output c hannel
2 way of analog signal output, each can be 4~20mA or 0~10V (for EDS800 series: 1 way of analog signal output, through them the inverter can realize output of physical parameter such as setting frequency, output frequency and etc.
K eypad
Special channel of EDS2800
LED display
Button lock
Protection function
Parameters copy
2-way 0-1A isolated analog input signal
Can display setting frequency, output frequency, output voltage, output current etc. in total 20 kinds of parameter (ED S800 has 14 kinds of parameter)
Lock all of the buttons; For EDS1000/EDS800: Lock all or part of the buttons(analog potentiometer can’t be locked)
Parameters can be quickly copied. by using of keyboard and remote-control ke ypad(EDS800/EDS1000 series no this function)
Over -current protection, over-voltage protection, lack -voltage protection, over-heat protection, over-load protection etc.
Brake subassembly, remote-control keypad, connecting cable for remote-control keypad etc.
Ambient
Optional parts
Use ambient
Altitude
Ambient temperature
Ambient humidity
V ibration
Configuration
Storage temperature
Defending grade
Cooling mode
Mounting mode
Options for EDS2080 series
Indoor, not bare to sunlight, no dust,no corrosive gas,no flammable gas, no oil fog, no vapor, no water drop or salt etc.
Lower than 1000m
-10ºC~+40ºC(under ambient temperature 40ºC ~50ºC, please reduce the volume or strengthen heat sink)
Smaller than 95%RH, no condensation water
Smaller than 5.9m /s² (0.6g)
-40ºC~+70º C
IP20
By fan with automatic temperature control
Wall -amount for type of 132kwG/160kwP and below, cabinet /wall-amount for type of
160kwG/200kwP and above, all of the EDS2800 series are wall-amoun t.
Isolating switch, circuit breakers, fuses, AC input / output reactors, the input / output EMI filters, ammeter, voltmeter, frequency meter
(Actual specification shall be a bit different from above depending on different types, please refer to user's manual or consult with manufacturer when you choose our products)
1
EDS-V300 current vector inverter
Suitable for: machine tools, wood machinery, stone machinery, mining machinery, printing machinery, drawing machine, textile, paper making, metallurgy, food, chemical, transmission, wire and cable, ceramic industry, building materials, packaging machinery, tobacco, and other sites and industries.
Power range: 0.4kw~3.7kw(220V)
0.75kw-55kw (380V)
Installation size, packing size and gross weight
Inverter type
A
(mm)
B
(mm)
W
(mm)
H
(mm)
D
(mm)
D1
(mm)
Fixing aperture
(mm)
Packing size
(cm)
EDS-V300-2S0004 EDS-V300-4T0007
EDS-V300-2S0007 EDS-V300-4T0015
EDS-V300-2S0015
EDS-V300-2S0022
EDS-V300-2S0037
EDS-V300-4T0022
EDS-V300-4T0037
EDS-V300-4T0055
EDS-V300-4T0075
EDS-V300-4T0150
EDS-V300-4T0185
EDS-V300-4T0220
EDS-V300-4T0300
EDS-V300-4T0370
EDS-V300-4T0450
EDS-V300-4T0550
110
140
185
135
180
200
200
250
160
215
275
330
410
485
515
620
125
155
200
218
260
280
300
370
170
230
123.2
135.5
155 164
290
345
178
210
187
221
430
505
535
645
252
252
252
258
261
261
261
267
4
5
6
7
9
9
9
12
25*20* 22
33*24*25
38*29*27
47*34*33
55*36*34
63*38*34
63*40*45
73*47*37
Gross weight
(kg)
Figure
3.8
6.3
10
17
23
33
52
2 Fig.a
Fig.b
Fig.b
Fig.c
Fig.c
Fig.c
Fig.c
Fig.c
B asic running wiring diagram
Adapted type: EDS-V300-2S0004~EDS-V300-4T0550
Braking resistance (external, fitting part)
Braking unit (external, fitting part)
Reactor (external)
3 phase
380V
50/60Hz
Breaker
P P+
R (L1 220V AC)
S (L2 220V AC)
T
Forward run/stop
Reverse run/stop
FWD
REV
Multi-function 1
X1
Multi-function
Multi-function
2
3
Multi-function 4
X2
X3
X4
Multi-function 5
Multi-function 6
Multi-function 7
(H-speed impulse input)
Multi-function 8
(H-speed impulse input)
Speed command
0~1 0V
X5
X6
X7
X8
COM
+10V/5V
0~10V 或 4~20mA
0~5V 或 0~10V
VCI
CCI
YCI
PB
EDS - V300
GND
P-
GND
AO1
AO2
DO
U
V
W
E
COM
OC1
OC2
OC3
OC4
COM
RS485+
RS485-
GND
TA
TB
TC
M
DC ampere meter
4 -20mA current signal
DC voltmeter
0~10V voltage signal
Cymometer
Outp ut 24V impulse signal
O pen circuit collector output
― +
Malfunction relay output
RS485 communication port
5 6
P
roduct Features
1.Adopt current vector control technology, and optimize V / F control simultaneously;
2.Big torque at low frequency: output 150% rated torque at 0.5Hz;
3.High steady-state accuracy: error rate of speed signal input and actual speed output is ±0.5%;
4.Unique self-learning technology: After entering the motor nameplate parameters, the inverter will start static and rotary tuning itself, in order to dynamically recognise motor parameters needed by motor vector control;
5.Good robustness: Generally not sensitive to motor parameters, not too dependent on parameters change, strong resistance toenvironment temperature change;
6.Simple and easy to adjust: No special setting for the motor and controller parameters. If any wrong parameter setting, just resume to factory setting;
7.Fast and stable high speed down response, maximum frequency accelerating/decelerating time can be 0.1s;
8.Even there are sudden change of load, rapid acceleration and deceleration, inverter can do fast and intelligent self-adjustment. So rare over current, short circuit fault and etc.;
9.Offer many kinds of frequency input ways, RS485 communication interface of MODBUS protocol as Standard configuration.
Outer dimension
Wave form
A
B C
Current wave form at 0.5Hz
Effective compensation for non-linear interference to the inverter
Current form of sudden load during hi-speed running
Current form of 0.1s accelerated stop DC braking
电机
转速
频率
负载
50HZ
45HZ
空载
(r/min)
1498
1347
40HZ
35HZ
30HZ
1197
1047
898
25HZ
20HZ
15HZ
10HZ
749
599
449
300
100%
(r/min)
1498
1351
1202
1049
897.4
748.4
599.7
455.5
307
150%
(r/min)
1494
1347
1201
1052
894.5
746.5
598.9
457.6
310.3
Speed accuracy ±0.5%
Current form of sudden load at 0.5Hz
2
EDS580 series
1、Smart design, with the motor naturally
2、Sophisticated design, super strong capability of withstanding harsh environment
3、Safe design, protecting equipment handily
4、User-friendly design, ensuring efficient work
5、Distinctive value, creating new ideas of application
Power range:3 phase 380V 0.75kw
Performance advantages:
1.Smart design, with the motor naturally
Breaking traditional design of structure and appearance for inverter, innovative integrated design with motor, inverter mounted directly on position of the motor terminal box, sparing need for installing cabinet and wiring, simple and convenient installation, strong anti-interference, compatible with the same power motor from different manufacturers, combined with the motor, and totally natural!
2. Sophisticated design, super strong capability of withstanding harsh environment
Fully enclosed metal casing design and unique lower power consumption design, not only energy-saving but also heat l osses reducing. To enhance the inverter's ability of anti-dust, anti-dirt and anti high-temperature, so it is able to show excellently for a long time even in harsh and complex environment!
3. Safe design, protecting equipment handily
Adopting pluggable dust-proof terminals externally, adding anti-jamming performance and overvoltage & over current design for internal hardware circuit, which resists strong electromagnetic noise, and protects the inverter in time even in exceptional situations. Collocation of external and internal part ensures stability and security of the inverter.
4. User-friendly design, ensuring efficient work
Excellent on-site operation makes all debug and control operations be done within the motor terminal box! (Also it can conduct multi-machine communication and PC operation through standard 485 communication interface.)
5. Distinctive value, creating new ideas of application
With ENC's strong and unique R & D strength EDS580 provides intelligent power for the motor, has a number of intellectual property and patents, and its innovative value is totally outstanding from other competing products; With help of EDS580, motor manufacturers can make speed adjustable intelligent motor system to improve the grade and value of existing motors; the inverter is also suitable forthe upgrade and re-equip of an existing project, which saves installation costs and improves the product reliability under dust and high temperature environment. EDS580 has great potential market value with its creative application of new ideas.
O
uter dimension
I
nverter specification explanation
Inverter type
EDS580-4T0007
Rated power
(KVA)
1.5
Rated current
(A)
Adapted motor
(KW)
2.3
0.75
B
asic running wiring diagram
R
S
T
U
V
W
F WD
X 1
X 2
0~10V DC
V C1
GN D
+ 10V
485A
485B
Standard RS485
RS485 通讯口
M
W
iring box disassembly diagram
1.Remove 4pcs M5 screw and disassemble upper cover of the wiring box.
2.Remove 2pcs M4 screw and disassemble the terminal.
3.Remove 4pcs M5 screw and disassemble lower cover of the wiring box.
M4 Screw
M5 Screw
M5 Screw
8
1
I
nstallation steps for EDS580
Install bracket onto motor by 4pcs M5 screw, and pass the motor wires through bushing and quadrate hole at the bottom of the bracket.
2
Install EDS580 onto the bracket by 6pcs
M4 screw.
3
M5 Screw
M4 Screw
Bushings
Square hole
Remove upper cover of EDS580, pass motor wires through the bushing and connect them to U, V, W.
Bushings U V W terminal
4
Connect power line to R, S, T and connect the earthing wire.
5
Connect wires to control wire terminal.
Earth wire
R S T terminal
Control line terminal
7
3
EDS780 Single-Board Inverter
1、 Small size, powerful function, extremely high cost performance
2、 Widely applicable in all types of control situation which needs installation
3、 Adopt space voltage vector SVPWM control
4、 Adopt independent 16 steps speed control; control is more accurate and convenient
5、 Good adaptability to power supply, can be applied to rural power grids with big fluctuation.
6、Panel control, terminal control and other methods controls can be realized
7、Configuration bulk capacitor can store certain pump energy.
8、Built-in simple PLC function, traverse function, more extensive adaptability.
9、Containing failure memory function, which is more convenient for finding problems.
10、RS485 interface as standard.
Power range:1 phase 220V 0.75KW
O
uter dimension
I
nstallation size
inverter type
EDS780-2S007
W(mm)
147.4
D(mm)
140.0
H(mm)
85.1
A(mm)
135.2
B(mm)
100
Fixing aperture
(mm)
5
4
I
nstallation size
Inverter type
(G: constant torque load; P: blower and water pump load)
EDS800 -2S0002
EDS800 -2S0004
W
(mm)
EDS800 -2S0007
EDS800 -2S0015 85
H
(mm)
141.5
D
(mm)
EDS800 -4T0007
EDS800 -4T0015
D1
(mm)
126
Fixing aperture
(mm)
5
Gross weight
(kg)
1
1
1.1
1.2
1.1
1.1
A
(mm)
B
(mm)
74 136
B
asic running wiring diagram
Braking resistance (external,fitting part,interface at the
right side of inverter)
O
uter dimension
T
echnic index and specifications
item
Rated volt., frequency
Allowed work volt. range
Voltage
Frequency single phase 220V, 50Hz/60Hz
Item description single phase AC 220V: 140 V~260V
200V grade: 0 -220V
0Hz -400Hz
Over loading capacity Maximum over -load capacity: 23 0% of rated current
Control mode
Speed regulation range
Space voltage vector SVPWM control
1:100
150% of rating torque at 1 Hz Start-up torque
Running speed stable state precision
Frequency precision
Frequency resolution
≤±0.5% of rating synchronous speed
Digital setting: max. frequency×±0.01%; analog setting: max. frequency×±0.5% analog setting 0.1% of max. frequency digital setting 0.01Hz
Torque boost Automatic torque boost , manual torque boost 0.1%~ 120%
Brake DC brake
Multi section s peed running
Automatic energy save running
Start-up and stop optional, action frequency 0~15Hz, action volt. 0~15%, action time
0~20.0 s
4 bits 16 sections speed control, each section speed parameter set seperately
Optimize V/F curve automatically based on the load to realize power save running
9
EDS800 Universal mini inverter
(CE Approval)
1 、 Small size (126*85*141.5mm), high cost performance.
2 、 Can make up of inverter network independently and can set to be mainframe or sub-device
3 、 Pulse/analog input output channels;
4 、 8 segments speed control;
5 、 Multiple running frequency/command specified channels;
6 、 Can realize copy for parameters by using long-distance keyboard;
7 、 Hi-performance isolating OC output, AC or DC load of 220V/0.5A can be connected;
8 、 Traversal function can be widely applied to all kinds of spinning devices;
Built-in Braking unit
Built-in user's timer/counter
Power range: 1 phase 220V 0.2kw~1.5kw ; 3 phase 380V 0.75kw~1.5kw .
10
Output 24V pulse signal
5
EDS1000 series multi-function universal inverter (CE Approval)
1、Small volume, be suitable for all kinds of spot;
2、150% of rated torque at 1 Hz frequency;
3、Built-in PID controller, can realize constant pressure (flux etc.) “One drives multiple devices” control (function in option);
4、16 (maximum) section speed control;
5、l0-20KHz pulse input output interface;
6、Spinning traverse function;
7、Bears automatic voltage regulation (AVR) and automatic current limiting function;
8、RS485 interface as optional part .
Power range: 1 phase 220V 0.4kw~3.7kw; 3 phase 380V 0.75kw~55kw;
3 phase 380V 18.5kw~132kw.
O
uter dimension
Fig.a outer dimeasion
Fig.c outer dimeasion
Fig.e outer dimeasion
Fig.b outer dimeasion
Fig.d outer dimeasion
D W
Fig.f outer dimeasion
11 12
I
nstallation size, packing size and gross weight
Inverter type
A(mm) B(mm) W(mm) H(mm) D(mm)
D1
(mm)
Fixing aperture
(mm)
EDS1000-2S0004
EDS1000-2S0007
EDS1000-4T0007G/0015P
EDS1000-4T0015G/0022P
110 160 125 170 123.2
135.5
4
Packing size
(cm)
Gross weight
(kg)
Figure
25*20*22 2 Fig.a
EDS1000-2S0022
EDS1000-4T0022G/0037P
EDS1000-2S0037
EDS1000-4T0037G/0055P
EDS1000-4T0055G/0075P
EDS1000-4T0075G/0110P
EDS1000-4T0110G/0150P
EDS1000-4T0150G/0185P
EDS1000-4T0185G/0220P
EDS1000-4T0220G/0300P
EDS1000-4T0300G/0370P
EDS1000-4T0370G/0450P
EDS1000-4T0450G/0550P
EDS1000-4T0550G/0750P
EDS1000-7T0110G/0150P
EDS1000-7T0150G/0185P
EDS1000-7T0185G/0220P
EDS1000-7T0220G/0300P
EDS1000-7T0300G/0370P
EDS1000-7T0370G/0450P
EDS1000-7T0450G/0550P
EDS1000-7T0550G/0750P
EDS1000-7T0750G/0900P
EDS1000-7T0900G/1100P
EDS1000-7T1100G/1320P
EDS1000-7T1320G/1600P
EDS1000-7T1600G/2000P
EDS1000-7T2000G/2200P
-
140 215
185 275
135 330
155
200
218
180 410
200 485
200
250
515
620
200
280
552
620
260
280
300
370
284
420
230
290
345
430
505
535
645
570
155 164 5
178 187 6
210
252
252
252
258
221 7
9 261
261
261
267
9
9
12
252.7
9
33*24*25
38*29*27
47*34*33
55*36*34
63*38*34
63*40*45
73*47*37
645*360*340
3.8
6.3
10
17
2 3
33
52
24
650 300 9 775*545*525 37
Fig.b
Fig.b
Fig.c
Fig.d
Fig.c
Fig.c
Fig.c
Fig.c
Fig.e
320
400
720
790
-
500
590
630
750 300 -
820 372 -
1200 500 -
12 875*625*525 68
Fig.d
12 945*715*595 93 Fig.d
830*1400*650 135 Fig.f
13
K eypad and keypad installation opening dimension (unit: mm)
Fig.a Kb5 Outer size
Suitable model :
EDS1000-4T0007G/P~EDS1000-4T0022P
Fig.b Keyboard hole size
Suitable model :
~EDS1000~2S0037
EDS1000-4T0022G/P~EDS1000-4T0550G/P
B
asic running wiring diagram
Braking resistance
(external,fitting part)
3 phase
380V breaker P+ PB
R(L1 220V AC)
S(L2 220V AC)
50/60Hz
Forward run/stop
Reverse run/stop
T
FWD
REV
Multi-function 1
Multi-function 2
X1
X2
Multi-function 3
X3
Multi-function 4
X4
Multi-function 5
X5
Multi-function 6
Multi-function 7
(H-speed impulse input)
X6
X7
Multi- function 8
(H-speed impulse input)
Speed command
0~10V
X8
COM
+10V/5V
0~10V or 4~20mA
0~5V or 0~10V
VCI
CCI
YCI
EDS1000
GND
Braking unit
P-
(external,fitting part)
U
V
W
E
M
GND
AO1
AO2
DC amperometer
4-20mA current signal
DC voltmeter
0~10V voltage signal
DO
COM
OC1
Cymometer
Output 24V impulse signal
OC2
OC3 open circuit collector output
OC4
COM
RS485+
RS485-
GND
TA
TB
― +
Malfunction relay output
TC
OptionalRS485 communication port
Adapted type:EDS1000-2S0004~2S0037
EDS1000 -4T0007G/P~EDS1000-4T0750P
EDS1100 series inverter for drawing machine:
1. Independently constitute dual-frequency digital PID control system;
2. To identify rolling diameter of line-receiving tray automatically;
3. Automatic identification of mechanical transmission ratio;
4. Automatic identification of diameter of cable;
5. Automatically adjust PID parameters;
6. Automatically track speed of mainframe, and after power on it will go to zero point of tensity balance bar (middle point);
7. Smooth starting, stable running, and constant tension;
8. System simplicity, low cost, easy maintenance, and more stable control effect
Power range: 3 phase 380V 0.75kw~37kw
13
6
EDS2000 series hi-performance universal inverter
1、 Takes DSP as the core, Dual CPU Control(Including the keypad CPU control)
2 、Low frequency (1Hz) large output torque.
3、Great overload capacity. 200% of rated current transiently
4、10 digital input channel, 3 analog input channel, can accept 0~10V, 0~5V and 4~20mA input single
2 pulse input channel (maximum 50 KHz), 2 OC digital output channel and 1 hi-speed pulse output channel are available.
5、Two 0~10V voltage and two 4~20mA current analog quantum output channel.
6、Output channel can be connected to standard secondary meter
7、16 (maximum) section speed control
8、RS485 interface as standard part
9、Remote keypad can be as long as 1000 meters off the inverter.
Power range:3 phase 380V 75~450KW
O
uter dimension
Fig.a
Fig.b
14
Fig.c
I
nstallation size, packing size and gross weight
Inverter type
A
(mm)
B
(mm)
W
(mm)
H
(mm)
D
(mm)
D1
(mm)
EDS2000 -4T0750G/4T0900P
300 650 480 680 360 369
EDS2000 - 4T0900G/4T1100P
EDS2000 -4T1100G/4T1320P
400 720 480 750 372 381
EDS2000 -4T1320G/4T1600P
EDS2000 -4T1600G/PA
EDS2000 -4T2000G/PA
400 740 480 770 410 —
EDS2000 -4T2200G/PA
EDS20 00-4T2500G/PA
EDS2000 -4T2800G/PA
EDS2000 -4T1600G/4T2000P
EDS2000 -4T2000G/4T2200P
EDS2000 -4T2200G/4 T2500P
420 1157 560 1200 430 —
500 1157 660 1200 430 —
—
—
—
—
600 1500 500
600 1600 500
—
—
EDS2000 -4T2500G/4T2800P
EDS2000 -4T2800G/4T3150P — — 700 1600 500 —
EDS2000 -4T3150G/4T3550P
EDS2000 -4T3550G/4T3750P —
EDS2000 -4T3750G/4T4000P
EDS2000 -4T4000G
EDS2000 -4T4500P
—
—
— —
— 900 1800 600 —
— 900 1800 600 —
EDS2800 -4T0110
EDS2800 -4T0150
EDS2800 -4T0185
140 350 230 370 212 223
180 440 260 460 252 261
EDS2800 -4T0300
EDS2 800 -4T0370
EDS2800 -4T0450
EDS2800 -4T0550
200 515 300 535 252 261
250 620 370 645 258 267
Fixing aperture
(mm)
12
12
121
14
14
—
—
—
—
—
—
7
9
9
12
Packing size
(m m)
605*810*570
605*880*590
605*900*635
725*1325*675
825*1325*675
765*1665*750
765*1765*750
905*1765*765
965*1915*800
1040*1940*870
1040*1940*870
460*310*300
550*350*340
630*380*340
475*750*475
Gross weight
(kg)
84
98
104
165
190
165
195
225
250
275
285
14.5
18.5
25.5
26
53
Figure
Fig.a
Fig.a
Fig.a
Fig.c
Fig.c
Fig.b
Fig.b
Fig.b
Fig.b
Fig.b
Fig.b
Fig.a
Fig.a
Fig.a
Fig.a
B
asic running wiring diagram
Braking resistance
(external,fitting part)
Braking unit
(external, fitting part)
DCL DC reactor
(external, fitting part)
3 phase breaker
R
380V
50/60Hz
Forward run/stop
Reverse run/stop
Multi -function1
Multi -function2
Multi -function 3
Multi -function 4
Multi -function 5
Multi -function 6
Multi -function 7
(H-speed impulse input)
Multi-function 8
(H-speed impulse input)
Speed command
0~10V
X1
X2
X3
X4
X5
X6
X7
X8 p
S
FWD
REV
COM
+10V/+5V
0~10V or 4~20mA
0~5V or 0~10V
VCI
CCI
YCI
P+ PB
EDS2000/
EDS2800/
EDS2860
P-
U
V
W
E
GND
A01
A02
DO
COM
Y1
Y2
CME
GND RS485+
RS485-
PE
TA
TB
TC
― +
M
DC amperometer
4 -20mA current signal
DC voltmeter
0~10V voltage signal
Cymometer
Output 24V impulse signal open circuit collector output
Malfunction relay output
Standard RS485 communication port
0~1A current signal
1I 2I
0~1Acurrent signal output channel 1 common end
1C 2C
Fig. 3-9 Basic wiring diagram channel 2 common end
Adapted type:EDS2000-4T0750G~EDS2000-4T4500P
EDS2800-4T0110~EDS2800-4T0550
15
7
EDS2860 series special inverter for injection molding machine (CE Approval)
1、Takes DSP as the core
2、Double loop for power source/power save running, automatic reset and power-off reset
function ensure production continuity and efficiency
3、Double channels input, can accept 0~1A (0-10V) signal and pulse signal under 200Hz
4、Great overload capacity: 150% of rated current for 3 minutes, 200% of rated current for
5 seconds
5、No high pressure flooding energy loss, power save rate reaches 25%~65%
6、Temperature of the oil is stable, cooling water can be saved by above 30%
7、The investment can be returned for about 6-15 months by power save.
Power range: 3phase 380V 7.5KW~75KW
O
uter dimension
16
O
uter dimension and gross weight
Inverter type
EDS2860 - 4T0075
EDS2860 - 4T0110
EDS2860 - 4T0150
EDS2860 - 4T0185
EDS2860 - 4T0220
EDS2860 - 4T0300
EDS2860 - 4T0370
EDS2860 - 4T0450
EDS2860 - 4T0550
EDS2860 - 4T0750
W
(mm)
260
280
320
360
435
520
D
(mm)
255
255
300
300
340
450
H
(mm)
570
600
675
770
875
1200
H1
(mm)
620
660
735
830
935
1250
Packing size
W*H*D(mm)
670*390*370
670*390*370
700*390*365
780*435*410
780*435*410
890*410*470
890*410*470
1020*560*570
1020*560*570
1380*790*750
Gross weight
(kg)
19
21
23.5
23.5
39
65
153
M
ain loop input output terminal description
Adap table type Main loop terminal Terminal name
EDS28 60 -4T0 075
EDS28 60 -4T0 750
R ,S , T
U, V ,W
E
Fun ction description
3 phase 380V input terminal
3 phase AC output terminal
Shielded earth terminal
B
asic control wiring diagram
Adaptable type: EDS2860-4T0075-EDS2860-4T0750 u
KM2
R U
S V v w
T W
21 22 uo vo wo pe
U
V
Motor
W connect
E termial
Ground wire termianl
Connect terminal
R
S
T
Run signal Flux signal Pressure signal uk vk wk
KM1
01
Option switch
KM1
Power save
02
Stop
Power source
03
KM2
04
05
Variable
LED2
KM2 frequenc y 8
9
Power
06
LED1
07
KM1
12
11
Remarks:
For control functions of EDS2860 series, please refer to EDS2800 series manual.
E
DS2800 series inverter
Have all the features of EDS2000 series
Full load output at Low-frequency (0.1Hz).
With powerful over load ability--- 150% of rated current 3 minutes, 200% of rated current 5 seconds.
Perfect control function for injection molding machine.
Provide 2-way 0-1A and 2-way 0-10V isolated analog input signal channels
Effective control of the excitation current can control the heating of injection molding machines effectively
Power range: 3phase 380V 11KW~75KW
EDS2080 series bypass/variable frequency integrated energy save and control machine
Have all the features of EDS2000 series
Bears automatic voltage regulation (AVR) and automatic current limiting function
Power source/Variable frequency dual-loop operation with automatic reset, power-off reset function
Be able to retain the original loop system
Can add isolating switch, breaker/ fuse, AC input / output reactors, input / output EMI filters and other accessories according to customers' need.
Can add ammeter, voltmeter, cymometer and etc. according to customers' need.
Power range:3phase 380V 7.5KW~400KW
S
pare parts selection
K
eyboard:
EN-KB1 (Local keyboard for EDS2000)
EN-KB3 (Romote-control keyboard for EDS2000)
EN-KB5 (Small local keyboard for EDS800/EDS1000 below 2.2KW (included))
EN-KB6 (Local keyboard for EDS1000 above 3.7kw (included))
EN-KB8(Romote-control keyboard for EDS1000,Modbus protocol)
EN-KB16(Romote-control keyboard for EDS1000,profitbus protosol)
The distance between inverter and EN-KB3 can reach 1000 meters maximally.
Our inverters support local keypad and long distance keypad synchronously, no priority, you can operate the inverter through both of them at the same time.
Failure alarm indicate light
Mode indicator light
Digital display (LED)
Forward run indicate light
Reverse run indicate light
Displayed current unit (A)
Displayed voltage unit (V)
Displayed frequency unit (Hz)
Failure alarm indicate light
Mode indicator light
Digital display (LED)
Run key
Shift/ Supervision key
Program/Exit key
Run key
Stop/Rest key
Program/Exit key
Confirm/Data key
Analog potentiometer
Joy key
Shift/ Supervision key
EN - KB1 keyboard
keyboard extending and hole size :
EN-KB5 keyboard
Forward run indicate light
Reverse run indicate light
Displayed current unit (A)
Displayed voltage unit (V)
Displayed frequency unit (Hz)
Stop/Rest key
Analog potentiometer
Joy key
Confirm/Data key
Date change key
Keyboard extending holder 1
88±0.10
Hole size for holder 1
(3.7kw and above)
Keyboard extending holder 2
88
Hole size for holder 2
(3.7kw and above)
Hole size for Kb5
Extending wire for KB5 Holder 1 and wire Holder 2 and wire Holder and wire for remote-control keyboard
Mounting dimension figure for constant pressure water supply controller:
Constant pressure water supply controller
17 18
C
onnection between inverter and fitting parts
(1) Must assemble disjunction device such as isolation switch etc. between power source and the inverter to assure personal safety when repairing the inverter and needing compulsory power off.
(2) Power supply loop must have breaker or fuse with over current protection function to avoid malfunction
T
N
R
S
Isolation switch
Breaker or fuse expanding causedby failure of after device.
(3) AC input reactor
If high-order harmonics between inverter and power supply is biggish which can't fulfil system requirement, or need to improve input side power factor, AC input reactor is needed.
(4) Contactor only be used to power supply control and can't be used to control the start/stop of inverter.
R S T
PE
EDS2000/
EDS2800/
EDS2860
U V W
AC input reactor (in option)
Magnetic control conductor
Input EMI filter (in option)
DC output reactor( in option )
Brake unit (in option)
Brake resistance (in option)
(5) Input side EMI filter
Can use EMI filter to inhibit high-frequency conduction disturbance and emission disturbance from inverter power inverter and fittings parts supply wire.
(6) DC reactor
M
Output EMI filter (in option)
AC output reactor(in option )
Built-in DC reactor as standard configuration for EDS2000-4T1600G/4T2000P and type of higher power, put-outside DC reactor as fitting part for type of power lower than EDS2000-4T11600G/EDS2000-4T1600P.
To avoid the inverter from affecting by power supply and to protect the inverter and to inhibit high order harmonic, should deploy DC reactor under following situations.
① When there is on-off blind power compensation capacitor or controlled silicon phase control load at the same power supply for the inverter, it's possible to damage input rectifying circuit of the inverter because on/off switching of capacitor may cause sudden change of power network voltage and phase control load cause harmonic and power network wave-form aberration.
② When unbalance degree of 3 phase power supply for the inverter exceeds 3%.
③ When input side power factor of the inverter is required to reach above 0.9.
④ Under normal situation, DC reactor is needed for the inverter when capacitance of power supply is larger than 10 times of inverter capacitance.
(7) Output side EMI filter
Can use EMI filter to inhibit emission disturbance noise and wire leakage current from output side.
(8) AC output reactor
Advise assembling AC output reactor to avoid motor insulation damage, too large over current and inverter frequent protection when connecting wire from inverter to motor exceeds 50m.But voltage drop of AC output reactor must be considered. Improve input output voltage of the inverter or let the motor in lower volume to avoid burning off the motor.
(9) Complete ground wire
Inverter and motor must be earthed and grounding and the resistor should be smaller than 10Ω. Grounding wire should be shorter enough and the diameter bigger enough.
Enough means as follows (not smaller than following standard):
7.5KW or below motor:3.5mm² above copper wire
11~15KW motor:8mm² above copper wire
18.5~37KW motor:14mm² above copper wire
45~55KW motor:22mm² above copper wire
75 Kw and above motor: 38m ㎡ above copper wire
19 20
C
ommon speed regulation running
Basic wiring diagram (see Fig.1)
Realized function
(1) Realize stepless speed regulation to the motor, use keypad to control
start/stop and keypad digital potentiometer to adjust frequency.
(2) Bear failure warning function.
(3) Connect with cymometer,which indicates output frequency of the inverter.
Application field
Used for common speed regulation field,such as:transportation machine, china machine, baccy machine,metallurgy machine etc.
3 phase breaker
3 phase 380V
50/60Hz
R
S
T
EDS 1000/
EDS2 000
DO
COM
U
V
W
E motor
M
TA
TB
TC
Failing warning light
L1
L2
Frequency meter
T
erminal control running
Basic wiring diagram (see Fig.2)
Realized function
(1) Control forward run/reverse run of the motor by external on-off quantum.
(2) Control speed of the motor by 0~10V signal.
(3) Bear failure warning and output current indication function.
Application field
Used in field where need long-distance control to start/stop of the motor such as blower, food, chemical machine, packing machine, transportation machine etc.
Fig. 1
3 phase 380V
50/60Hz
Forward run
Reverse run
Specified signal 10K
3 phase breaker
R
S
T
EDS 1000/
EDS20 00
FWD
REV
COM
10V/5V
VCI
GND
Fig. 2
AO1
GND motor
U
V
W
E
M
TA
TB
TC
Failing warning light
L1
L2 ammeter
M
ulti-step speed control running
Basic wiring diagram (see Fig.3)
Realized function
(1) Make use of external on-off quantum signal to control start/stop of the
3 phase breaker motor.
(2) Make use of external on-off quantum signal to make the motor run at set
3 phase 380V
50/60Hz frequency.
(3) Bear free shutdown and reset function by utilizing external on-off quantum signal.
Forward run
Reverse run mu1ti-step speed control 1
(4) Bear warning alarm and PLC run indication function.
mu1ti-step speed control 2 1 mu1ti-step speed control 3
Application field:
Free stop reset
Applied in field where need frequent multi-speed adjustment to motor speed such as toughened glass, weaving, paper making, chemical etc..
R
S
E D S 10 0 0 /
E D S 20 0 0
T
FWD
REV
COM
X1
X2
X3
X4
X5
Fig. 3
OC1/Y1
W
E
U
V
TA
TB
TC
COM
M otor
M
Failing warning light
L1
L2
PLC run indicator light
24V
C
losed-loop control system
Basic wiring diagram (see Fig.4)
Realized function
(1) The inverter can adjust output automatically according to feedback signal to make constant voltage, constant temperature, constant current etc. available.
(2) Can control start/stop of the motor from long distance.
(3) Bear failure alarm and current indicator function.
Application field:
Applied in field where need stable system, pressure, flux such as blower pump, constant pressure water supply, air compressor, air conditioner, freezer cooling tower, music fountain, heat supply etc..
3 phase breaker
3 phase power supply
Forward run
Reverse run
Specified signal 10K
4-20mA/ 0-10V feedback signal
R
S
T
FWD
REV
COM
10V/5V
VCI
GND
CCI
EDS2000/
EDS2800 /
EDS2860
Fig. 4
U
V
W
E motor
M
TA
TB
TC
Failing warning light
L1
L2
AO1 ammeter
GND
ENCOM is national outstanding brand. Honor: National Innovation Fund,Shenzhen
Hi-tech R&D Subsidies Shenzhen Software Association Member China Merchants
Technology Group Member Seven automatic production lines Porduction capacity is 2,6000 pieces/month
C
onsecutive action running
Basic wiring diagram (see Fig.5)
Realized function
After receive forward run command from external switch(closed) and frequency specified value(0~10V) from analog input terminal YCI, 1#inverter run at this frequency value. At the same time, already running state of 1# inverter,make 2# inverter get forward run command through serial communication, here, run frequency value of 1# inverter is passed to 2# inverter through serial communication.
Application field
Applied in field such as conveyer belt, coiler, factory production line, food chemistry etc.
3 phase power supply
FWD command
10KΩ
QF
R
S
T
FWD
COM
1#
EDS1000
10V/5V
YCI
GND
TA
TB
TC
485+
U
V
W
E
485-
M
Failing warning light
L1
L2
Fig. 5
QF
R
S
T
485+
485-
2#
EDS1000
U
V
W
E
TA
TB
TC
M light
L2
E
nergy save engineering for injection molding machine
Basic wiring diagram (see Fig.6)
3 phase breaker
Realized function
3 phase 380V
50/60Hz
(1) Control forward run of the motor by start-up button.
(2) Control speed of the motor by using current signal acquired by injection molding machine.
(3) Bear failure warning output function.
Reset
Forward run
Common end
T
R
S
X1~X6
FWD
COM
1I
1C
Power source frequency/variable frequency convertor
EDS2800 /
EDS2860
W
E
U
V
Fig. 6
Motor
M
TA
TB
TC
AO1
Failure warning light
L1
L2
GND
Ammete r
T
he application for drawing machine
Basic wiring diagram (see Fig.7)
The pull-in current of intermediate relay KA6, Ka8 shoud be less than 50mA; otherwise please use an external power supply.
Realized function
Constitute an independent dual-frequency digital PID control systems, keep the work of wire drawing machine in a way of smooth start-up, run a smooth, constant tension and to start/ stop at any time.
Application field
Wire drawing machine, automatic wire & cable winding machine etc.
Fig. 7
ENCOM has passed ISO9001:2008 quality control system approval
CE certification:EDS800,EDS1000,EDS2860 series
6860㎡ brand-new manufacture base
Advanced test instruments, whole unit inspecting before and after ageing test
We promise ENC® INVERTER is no defect before shipment
21 22
Use case Project Description
The use of inverter
Power quantity
Liaoning Publishi ng Shenyang
Book Distribution Center
Jiangsu Weida Chemical Fiber
Group
Zhejiang Jiantai Optical
Instrument Factory
Guangdong Shuang Xin
Cement Plant
Guangdong Bai Yun Cement
Plant
Plant
Jiang Xi Bao Ma/Si Chuan Jin
Chuan Cement Plant
Yantai Foxconn DT Molding
Qing Dao LangDi Group
Central air -conditioning networking control system
Chemical fiber equipment system
Energy -saving control of injecti on molding machine
Large -scale energy -saving cement plant fan
Large -scale energy -saving cement plant fan
Large -scale fan energy -saving cement plant
Energy Saving of Injection Molding
Machine
Energy Saving of Injection Molding
Machine
Shengli oil field water injection pump
Shengli Oilfield
Linyi Zhen -yi Thermal power plant frequency transformation
Fans Energy-saving in power plant
Shenyang, Heping District Heating
Company
Variable frequency transformation in heating
22KW
7.5~132KW
15KW
15~315KW
220KW
200KW
15~45KW
15~55KW
200~315KW
132~280KW
75~250KW
24
260
18
20
1
1
103
26
9
3
10
Tai Jie cleaning washing machine
Equipment Co., Ltd.
Dry Cleaning Machine Series
Jiangsu Huan Yu Machinery
Equipment Co., Ltd
Zhejiang Aviation Equipment
Factory
Dehydration Machine Series
CNC machine tools
Guangdong Zhang Yu Plastic
Factory
Da Qing Oilfield
Boot disk drive energy-saving system
Pumps
1.5KW
7.5~15KW
1.5KW
18.5~22KW
315KW
500
8
60
82
3
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project