Minka Lavery 1553-477 Installation Guide

INSTALLATION INSTRUCTIONS FOR 1553-477
For Wall Mount Fixture
WARNING!
SHUT POWER
OFF AT FUSE OR
CIRCUIT BREAKER .
MOUNTING THE FIXTURE
Installation (see fig.1)
Wiring (see fig.2)
1.Shut off the power at the circuit breaker and remove old fixture,
1.Connect the electrical wires as follows. Connect the
including the crossbar.
black wire from the fixture to the black house (hot)
2.Attach the crossbar to the junction box using two junction box
Wire. Connect the white wire from the fixture to the
screw. The side of the crossbar marked “GND” must face out.
white (neutral) house wire. Make sure all wire nuts are
3.Thread the nipple part way into the center hole of the crossbar and
secured. You may wrap the connections with electrical
secure with hex nut.
tape. If your outlet box has a ground wire (green or bare
4.Follow wiring instructions carefully (see fig.2)
copper) connect fixture’s ground wire to it. Otherwise
5.Place the fixture over the nipple, then tighten it with cap nut (B).
attach the bare copper fixture wire to the green ground
6.Protrude the pipe (F) through hex nut (E), the washer (M), the hole
screw on the crossbar.
of bracket (A),and the washer (D) over pipe (F), then screw the
2.Tuck the wire connections neatly into the wall junction
hex nut (C) onto pipe (F).
box.
7.Raise glass shade (G) to main body, aligning glass hole with pipe
(F), attach rubber cushion (H) and the washer (I), then screw it with
hex nut (J). attach the finial base (K) to the end of pipe (F) and
tighten firmly with finial (L).
8.Install the light bulbs in accordance with the fixture’s specifications.
DO NOT EXCEED THE MAXIMUM WATTAGE RATING!
Fig.1
Fig.2
MIN 90℃ SUPPLY CONDUCTORS