Sea Gull Lighting 3211-185 Installation Guide

Installation And Safety Instructions
HC-229
Line art shown may not exactly match the fixture enclosed. However, the installation instructions do apply to
this fixture. Fill in Item Number on Carton and File This Sheet For Future Reference. ITEM#_______________
FOR YOUR SAFETY
092998
ASSEMBLY
WARNING: BE SURE THE ELECTRICITY TO THE WIRES YOU ARE WORKING ON IS SHUT OFF. EITHER THE FUSE REMOVED OR THE CIRCUIT
BREAKER OFF.
GENERAL
Carefully remove the fixture from the carton and check that
all parts are included, as shown in Figure 1 & 2. Be careful
not to misplace any of the screws or parts which are needed
to install this fixture.
STEP 1:
You don’t need special tools to install this fixture. Be sure to follow the steps
in the order given. Under no circumstances should a fixture be hung on
house electrical wires, nor should a swag type fixture be installed on a ceiling
which contains a radiant type heating system. Read instructions carefully. If
you are unclear as to how to proceed, consult a qualified electrician.
*OUTLET BOX
*WIRE CONNECTORS
*GROUND WIRE
Attach loop [I] to top of fixture (if applicable).
WARNING: TO REDUCE THE RISK OF FIRE,
ELECTRIC SHOCK OR PERSONAL INJURY,
MOUNT TO OUTLET BOX OR SUPPORTING
SYSTEM ABLE TO SUPPORT THE WEIGHT OF
THE FIXTURE.
MOUNTING BAR (A)
*OUTLET BOX
GROUNDING AND MOUNTING BAR LOCK UP
*OUTLET BOX
SCREWS
*GROUND WIRE
*WIRE
CONNECTORS
GROUND WIRE (F)
SCREW COLLAR (E)
CANOPY (H)
MOUNTING
BAR (A)
*OUTLET BOX
SCREWS
SCREW COLLAR
RING (G)
CHAIN (S)
FIXTURE LOOP (I)
GREEN
GROUNDING
SCREW (D)
FIGURE 2
*NOT INCLUDED
THREADED
GLASS
RETAINER
RING (L)
(If applicable)
GLASS (J)
SOCKET (K)
CENTER
LIGHT
(IF APPLICABLE)
*NOT SUPPLIED
FIGURE 1
NUT (B)
NIPPLE (C)
INSTALLATION
HC-229
IMPORTANT: DO NOT ATTACH FIXTURE DIRECTLY TO OUTLET
BOX.
STEP 1:
Secure mounting bar (A) to outlet box with outlet box screws (not
supplied). Thread nut (B) on nipple (C) so that 3 threads are
exposed above nut (B). Thread nipple (C) into mounting bar (A) and
secure with nut (B). Attach screw collar (E) to nipple (C).
STEP 2:
Using 2 pairs of pliers, open one link of chain (S) and connect it to
the fixture loop (I) at the top of the fixture.
STEP 3:
Slide the screw collar ring (G) and canopy (H), in that order, over
chain (S). Open one link on the other end of the chain (S) and
attach it to the screw collar (E) which has been mounted to the
ceiling nipple (C).
BE SURE TO CLOSE ALL CHAIN LINKS COMPLETELY.
STEP 4:
Lace wires up through chain (S) and pass wires through holes in
screw collar (E). We recommend lacing wire up through every other
link of chain (S).
C. Fit a wire connector (not supplied) over the wires and screw the
connector clockwise until you feel a firmness.
D. Try gently to pull the connector off the wires. If you can pull the
connector off, carefully re-do steps B and C, as above and check
again for a firm connection.
E. Connect the fixture wire from group B to the white wire from the
outlet box in the same manner.
STEP 6:
GROUNDING INSTRUCTIONS: The green grounding screw (D) is
to be inserted into the hole with two raised dimples provided on
the mounting bar (A). Wrap the ground wire (F) from the fixture (if supplied) and the ground wire from the outlet box (bare metal or
green insulated wire) around the green grounding screw (D) on the
mounting bar (A) if uninsulated wire is on the mounting bar (A),
connect the ground wire (F) from the fixture (if supplied) and the
outlet box to it using a small wire connector (not supplied).
NOTE: Underwriters Laboratories does not require all fixtures to
have ground wires. These fixtures still meet all UL specifications.
NEVER CONNECT GROUND WIRE TO BLACK OR WHITE
POWER SUPPLY WIRES.
FINAL ASSEMBLY
Make sure no bare wires can be seen outside wire connectors.
STEP 1:
STEP 5:
A. Take note of the color of the wire(s) on your fixture. Identify
which group your fixture wire(s) falls into and connect the wires
according to the directions below:
After wires are connected, tuck them carefully inside outlet box.
Raise canopy (H) against ceiling and screw the screw collar ring (G)
to the screw collar (E).
STEP 2:
Slide glass (J) over socket (K) and secure in place by threading the
threaded glass retainer ring (L) on socket (K) (If applicable).
STEP 3:
Install lamps.
NOTE: Due to the variation among hand blown glass shades
(diffusers), your fixture may not hang straight. Try to reposition or
switch the glass shades around.
GROUP A: CONNECT TO BLACK
HOUSE WIRE
BLACK
GROUP B: CONNECT TO WHITE
HOUSE WIRE
WHITE
NOTE: (If applicable) If not enough threads are exposed on candle
cover for glass retaining ring (L) to hold down glass (J), unscrew
candle cover as needed.
CLEANING
*PARALLEL WIRE (ROUND & SMOOTH)
*PARALLEL WIRE (SQUARE & RIDGED)
WHITE OR GREY WITH TRACER
WHITE OR GREY WITHOUT TRACER
BROWN, GOLD OR BLACK WITHOUT TRACER
BROWN, GOLD OR BLACK WITH TRACER
*Note: When parallel wire is used, the tracer wire is square shaped
or ridged and less tracer wire is round in shape or smooth.
(Seen best when viewed from wire end.) To separate wires, grasp
the ends of each wire and pull apart.
B. Take your fixture wire(s) from group A and place evenly against
the black wire from the outlet box. DO NOT twist wires together
before using wire connectors.
To clean, wipe fixture with a soft cloth. Clean glass with a mild soap.
Do not use abrasive materials such as scouring pads or powders,
steel wool or abrasive paper.
ORDERING PARTS
Keep this sheet for future reference, and in case you need to order
replacement parts. All parts for this fixture can be ordered from
place of purchase. Be sure to use exact wording from illustration