SETTINGS FOR PELCO TELEMETRY D-PROTOCOL
- Settings for EDA-995 like before
- EDR1600/400 Camera Menu: Model Pelco, 2400 Baud,
PTZ - ID = Dome adress
- Dome: Connect RX+ to EDA995 / pin 1 and RX– to E
DA995/ pin 2, daisy-chain-wiring is required
- Dome: Set PELCO D—protocol, 2400 Baud, adress = PTZ
ID at EDR1600/400
- last dome in RS-485 bus has to be terminated with 120
Ohm, all other domes termination off
EDA-995
Interface converter
RS232 / RS485
LAYOUT CONNECTOR CABLE RS-232
SUB-D 25-pin male
2 3 4 5 7
2 3 8 7 5
SUB-D 9-pin fem.
Serial connector cable RS232
SPECIFICATIONS
Protocoll:
Data rate:
Maximum cable length:
Isolation/
Surge protection
Weight:
Power supply:
Dimensions:
RS485 duplex / half duplex
up to 100 Kb/s
1200m
up to 2000 V DC
60 g
9 VDC, 200 mA
54x74,5x18,5 mm
EverFocus ®
EDA995_ma_en_r1.00
PACKAGE CHECKLIST
INSTALLATION WITH ED2200 SPEED DOME
Please check the box for containing following items:
•
1 x converter RS232/RS485
•
1 x adapter cable RS232 9 pin fem. / 25 pin male
•
1 x power supply 9VDC / 200 mA
•
1 x manual
120 Ohm OFF
T-ON
R-ON
4
3
2
1
T-RTS
R-RTS
TX TX +
T-RTS
R-ON
ED2200
GND
SW1
DTE
DCE
SW2
EDR1600/
EDR400
COM2
SECURITY ADVICES
1.
2.
3.
120 Ohm OFF
ED2200
TX TX +
To prevent electric shock caused by lightening a groung path
has to be provided by connecting the GND screw connector to
earth ground.
Do not open the unit. No user serviceable parts inside.
To reduce risk of electric shock or fire, do not expose this unit
to rain or moisture
120 Ohm ON !
ATTENTION!
Ground connection is necessary for correct working surge protection!
ED2200
TX TX +
SETTINGS INTERFACE CONVERTER
WARNING:
This equipment has been tested and found to comply with the limits
for a Class “A” digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance
with the instruction manual, may cause interference to radio communications. Operation of this equipment in a residential area is likely
to cause harmful interference in which case the users will be required to correct the interference at their own expense.
SW1: T-ON/R-ON
SW2: DTE
Connect pin 1 and 4, 2 and 3 at the screw terminal block
SETTINGS EDR400 /1600
Menu Camera:
- PTZ ON for according speed dome
- PTZ ID is dome adress
- PTZ setting:
Model: EverFocus ED2200
Baud rate: 4800
Protocoll: 8,1,none
SETTINGS ED2200
-
Half duplex (SW501 3 OFF)
Protokoll A (SW501 6,7,8 OFF)
4800 Baud (SW501 4,5 ON)
adress = PTZ ID
last ED2200 in RS-485 bus: 120 Ohm termination ON
(SW501 1,2 ON), all other domes termination off (SW501 1,2 OFF)