GENESIS® IndoorAirConditioners


McLean Cooling Technology: Air Conditioners: 
Product Overview

GENESIS®
Indoor Air Conditioners
M52 460 Volt
3-Phase Model
M28 Model
M17 Model
68
Subject to change without notice
800-896-2665 • McLeanCoolingTech.com © 2010 Pentair Technical Products

: 
Product Overview

The specifier’s choice for
cooling industrial process controls
GENESIS® Indoor Air Conditioners
PRODUCT OVERVIEW
The Type 12 air conditioner of choice for light-duty manufacturing
process control applications. Compact, narrow and 460 volt 3-phase
models available.
APPLICATIONS
• Industrial drive enclosures
GENESIS Chapter Contents
Indoor Air Conditioners . . . . . . . . . . . . . . . . 70
M13 Models 1000 BTU/Hr.. . . . . . . . . . . . . . . 71
M17 Models 1800 BTU/Hr.. . . . . . . . . . . . . . . 73
M28 Models 2200 BTU/Hr.. . . . . . . . . . . . . . . 75
M28 Models 4000 BTU/Hr.. . . . . . . . . . . . . . .76
M28 Models 6000 BTU/Hr.. . . . . . . . . . . . . . .77
M33 Models 4000 BTU/Hr.. . . . . . . . . . . . . . . 79
M36 Models 6000 BTU/Hr.. . . . . . . . . . . . . . .81
M52-3 Phase Models 
4100-10000 BTU/Hr.. . . . . . . . . . . . . . . . . . . 83
• Automotive assembly systems
• Material handling applications
• Other process control systems
Subject to change without notice
800-896-2665 • McLeanCoolingTech.com © 2010 Pentair Technical Products
69
GENESIS A/C
McLean Cooling Technology: Air Conditioners
GENESIS®
McLean Cooling Technology
Air Conditioners
GENESIS®
Indoor Air Conditioners
M17
1800 BTU/Hr.
527 Watt
M28
2200-6000 BTU/Hr.
645-1758 Watts
Industry Standards
UL/cUL Listed, CE, others available upon request
•• Type 12
Application
••
••
••
••
Industrial automation
ackage handling equipment
P
Security and defense systems
And more
••
••
••
••
••
••
Subject to change without notice
•• M
ounting hardware, gaskets and user manual furnished with the
unit
•• Every unit functionally tested before shipping
•• Standard Indoor Air Conditioner models also include:
- Electro-Mechanical Thermostat
- Surge Suppressor
- Condensate Management System
Finish
Robust reciprocating compressor
134a or R407c earth-friendly refrigerant and RoHS compliant
R
Models for 115, 230 and 460 single phase AC volt power input
UL Listed or Recognized to save customers time and money with
agency approvals
Operating temperature range from 50 F/10 C to 125 F/52 C
Attractive industrial design with minimal use of visible fasteners
Reliable mechanical thermostat located behind the filter of the
unit. Indoor Air Conditioner models include digital display on
ambient side.
Low-carbon mild-steel sheet-metal cover for rugged factory and
outdoor environments
Easy-mount flanges for simple installation
Cleanable, reusable aluminum mesh filter to protect coils for
maximum cooling performance
70
M52 3-Phase
4100-10000 BTU/Hr.
1201-2930 Watts
•• R
AL 7042 gray powder-coat paint in a semi-gloss finish
•• Other colors and textures available
Features
••
••
••
••
M36
6000 BTU/Hr.
1760 Watt
Options
••
••
••
••
••
••
••
T hermostat Malfunction Package
Special Voltage Package
Active Condensate Evaporator Package
Outdoor Package*
Harsh Environment Package*
Stainless Steel Package*
Heater Package*
* T-Series or PROAIR™ may be more appropriate. Refer to
T-Series A/C and PROAIR A/C chapters. Consult the factory for
availability and catalog number.
Notes
Visit www.McLeanCoolingTech.com to download 2D and 3D CAD
drawings into the overall design of your electronic system.
800-896-2665 • McLeanCoolingTech.com © 2010 Pentair Technical Products
Performance Data M28 Models 2200 BTU/Hr. (645 Watt)
MODEL NUMBER
COOLING PERFORMANCE
Nominal:
BTUs/Hr.
Watts
Refrigerant
Refrigerant Charge (ounces/grams)
Operating Temperature Range:
Maximum (°F/°C)
Minimum (°F/°C)
Air Flow at 0 Static Pressure:
Internal loop 50 Hz (CFM/M3/Hr.)
External loop 50 Hz (CFM/M3/Hr.)
Internal loop 60 Hz (CFM/M3/Hr.)
External loop 60 Hz (CFM/M3/Hr.)
ELECTRICAL DATA
Rated Voltage
Frequency (Hz)
Operating Range
Max. Power Consumption (Watts at 50/60 Hz)
Max. Nominal Current (Amps at 50/60 Hz)
Starting Current (Amps)
Agency Approvals
Power Input Description
ENCLOSURE PROTECTION
UL Type
CONTROLLER
Description
Thermostat Location
Factory Thermostat Setting (°F/°C)
SOUND LEVEL
At 1.5 Meters
UNIT CONSTRUCTION
Material
Subject to change without notice
M28-0226-G004
M28-0246-G400
2200/2200
645/645
R-134A
11/312
2200/2200
645/645
R-134A
10/284
2200/2200
645/645
R-134A
10/284
125/52
50/10
125/52
50/10
125/52
50/10
146/248
230/391
170/289
260/442
175/297
225/382
210/357
255/433
175/297
225/382
210/357
255/433
115
50/60
+/- 10%
1127/1035
9.8/9.0
28
230
50/60
+/- 10%
1150/1035
5.0/4.5
14.4
460V 1PH
50/60
+/- 10%
1288/1150
2.8/2.5
7.4
cUR Recognized
CE
cUL Listed
CE
Others available upon request
NEMA 5-15 plug on 6-ft. cord NEMA 6-15 plug on 6-ft. cord
6-ft. cord with wire terminations
Type 12 Standard
Basic Mechanical Thermostat
Behind Filter
80/27
55 dBA
Mild Steel Sheet Metal Standard
Stainless Steel Optional
Powder Coat RAL 7042 Gray Standard
28.5/724
17/432
11.3/288
98/45
28.5/724
17/432
11.3/288
98/45
GENESIS A/C
Finish
UNIT DIMENSIONS
Height (in./mm)
Width (in./mm)
Depth (in./mm)
Weight (lb./kg)
M28-0216-G013
28.5/724
17/432
11.3/288
108/49
800-896-2665 • McLeanCoolingTech.com © 2010 Pentair Technical Products
75
McLean Cooling Technology: Air Conditioners
GENESIS®
GENESIS A/C
McLean Cooling Technology: Air Conditioners
GENESIS®
Performance Data M28 Models 4000 BTU/Hr. (1172 Watt)
MODEL NUMBER
COOLING PERFORMANCE
Nominal:
BTUs/Hr.
Watts
Refrigerant
Refrigerant Charge (ounces/grams)
Operating Temperature Range:
Maximum (°F/°C)
Minimum (°F/°C)
Air Flow at 0 Static Pressure:
Internal loop 50 Hz (CFM/M3/Hr.)
External loop 50 Hz (CFM/M3/Hr.)
Internal loop 60 Hz (CFM/M3/Hr.)
External loop 60 Hz (CFM/M3/Hr.)
ELECTRICAL DATA
Rated Voltage
Frequency (Hz)
Operating Range
Max. Power Consumption (Watts at 50/60 Hz)
Max. Nominal Current (Amps at 50/60 Hz)
Starting Current (Amps)
Agency Approvals
Power Input Description
ENCLOSURE PROTECTION
UL Type
CONTROLLER
Description
Thermostat Location
Factory Thermostat Setting (°F/°C)
SOUND LEVEL
At 1.5 Meters
UNIT CONSTRUCTION
Material
Finish
UNIT DIMENSIONS
Height (in./mm)
Width (in./mm)
Depth (in./mm)
Weight (lb./kg)
76
Subject to change without notice
M28-0416-G007
M28-0426-G032
M28-0446-G400
3800/4000
1114/1172
R-134A
11/312
3800/4000
1114/1172
R-134A
11/312
3800/4000
1114/1172
R-134A
11/312
125/52
50/10
125/52
50/10
125/52
50/10
153/260
230/391
174/296
260/442
146/248
225/382
166/282
255/433
146/248
225/382
166/282
255/433
115
50/60
+/- 10%
1679/1610
14.6/14.0
48
230
50/60
+/- 10%
1702/1587
7.4/6.9
23
460V 1PH
50/60
+/- 10%
1886/1748
4.1/3.8
12
cUR Recognized
CE
cUL Listed
CE
Others available upon request
NEMA 5-20 plug on 6-ft. cord NEMA 6-15 plug on 6-ft. cord
6-ft. cord with wire terminations
Type 12 Standard
Basic Mechanical Thermostat
Behind Filter
80/27
Mild Steel Sheet Metal Standard
Stainless Steel Optional
Powder Coat RAL 7042 Gray Standard
28.5/724
17/432
11.3/288
116/53
28.5/724
17/432
11.3/288
116/53
28.5/724
17/432
11.3/288
136/62
800-896-2665 • McLeanCoolingTech.com © 2010 Pentair Technical Products
Technical Data M28 Models 6000 BTU/Hr. (1758 Watt)
MODEL NUMBER
COOLING PERFORMANCE
Nominal:
BTUs/Hr.
Watts
Refrigerant
Refrigerant Charge (ounces/grams)
Operating Temperature Range:
Maximum (°F/°C)
Minimum (°F/°C)
Air Flow at 0 Static Pressure:
Internal loop 50 Hz (CFM/M3/Hr.)
External loop 50 Hz (CFM/M3/Hr.)
Internal loop 60 Hz (CFM/M3/Hr.)
External loop 60 Hz (CFM/M3/Hr.)
ELECTRICAL DATA
Rated Voltage
Frequency (Hz)
Operating Range
Max. Power Consumption (Watts at 50/60 Hz)
Max. Nominal Current (Amps at 50/60 Hz)
Starting Current (Amps)
Agency Approvals
Power Input Description
ENCLOSURE PROTECTION
UL Type
CONTROLLER
Description
Thermostat Location
Factory Thermostat Setting (°F/°C)
SOUND LEVEL
At 1.5 Meters
UNIT CONSTRUCTION
Material
Subject to change without notice
M28-0626-G005
M26-0646-G400
5400/6000
1582/1758
R-134A
15/425
5400/6000
1582/1758
R-134A
15/425
5400/6000
1582/1758
R-134A
15/425
125/52
50/10
125/52
50/10
125/52
50/10
153/260
325/552
174/296
373/634
146/248
325/552
166/282
373/634
146/248
325/552
166/282
373/634
115
50/60
+/- 10%
1886/1978
16.4/17.2
58.8
cUR Recognized
CE
6-ft. cord with wire terminations
230
50/60
+/- 10%
1840
8
27.4
cUL Listed
CE
NEMA 6-15 plug on 6-ft. cord
460V 1PH
50/60
+/- 10%
2024
4.4
14
cUR Recognized
CE
6-ft. cord with wire terminations
Type 12 Standard
Basic Mechanical Thermostat
Behind Filter
80/27
62 dBA
Mild Steel Sheet Metal Standard
Stainless Steel Optional
Powder Coat RAL 7042 Gray Standard
120/55
28.5/724
17/432
11.3/288
120/55
GENESIS A/C
Finish
UNIT DIMENSIONS
Height (in./mm)
Width (in./mm)
Depth (in./mm)
Weight (lb./kg)
M28-0616-G005
150/68
800-896-2665 • McLeanCoolingTech.com © 2010 Pentair Technical Products
77
McLean Cooling Technology: Air Conditioners
GENESIS®
GENESIS A/C
McLean Cooling Technology: Air Conditioners
GENESIS®
M28 Models 2200-6000 BTU/Hr. (645-1758 Watt)
89044980
Cutout Instructions
Visit www.McLeanCoolingTech.com to download 2D and 3D CAD drawings into the overall design of your electronic system.
78
Subject to change without notice
800-896-2665 • McLeanCoolingTech.com © 2010 Pentair Technical Products