Sea Gull Lighting 31751-758 Installation Guide

INSTALLATION AND SAFETY INSTRUCTIONS
ASSEMBLY
FOR YOUR SAFETY
WARNING: BE SURE THE ELECTRICITY TO THE WIRES YOU
ARE WORKING ON IS SHUT OFF; EITHER THE FUSE IS
REMOVED OR THE CIRCUIT BREAKER IS SHUT OFF.
GENERAL
You don’t need special tools to install this fixture. Be sure to
follow the steps in the order given. Read instructions carefully. If
you are unclear as to how to proceed, consult a qualified
electrician.
*OUTLET BOX
*WIRE CONNECTORS
*GROUND WIRE
MOUNTING BAR (A)
Carefully remove the fixture from the carton and check that all
parts are included, as shown in Figure 1 and 2. Be careful not to
misplace any of the screws or parts which are needed to install
this fixture.
STEP 1:
Rotate arms (M) so arms are vertical, position lamp base down.
STEP 2:
Thread top assembly (L) onto fixture body (N). Gently pull wire
through top assembly. Thread fixture loop (I) to top assembly (L).
Gently pull excess wire through fixture loop.
STEP 3:
Thread bottom assembly (K) onto fixture body.
GROUNDING AND MOUNTING BAR LOCK UP
*OUTLET BOX
*OUTLET BOX
SCREWS
*GROUND WIRE
GROUND WIRE (F)
*WIRE
CONNECTORS
SCREW COLLAR (E)
CANOPY (H)
SCREW COLLAR
RING (G)
MOUNTING
BAR (A)
*OUTLET BOX
SCREWS
CHAIN (S)
FIXTURE LOOP (I)
TOP ASSEMBLY (L)
GREEN
GROUNDING
SCREW (D)
NUT (B)
NIPPLE (C)
FIGURE 2
*NOT INCLUDED
SHADE (P)
FIXTURE BODY
(N)
CANDLE COVER
(J)
ARMS (M)
BOTTOM
ASSEMBLY (K)
FIGURE 1
*NOT SUPPLIED
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK OR PERSONAL INJURY, MOUNT TO OUTLET BOX
OR SUPPORTING SYSTEM ABLE TO SUPPORT THE
WEIGHT OF THE FIXTURE.
Installation And
Safety Instruction
HC-821
013107
Line art shown may not exactly match the fixture enclosed.
However, the installation instructions do apply to this fixture.
Fill In Item Number On Carton And
File This Sheet For Fixture Reference.
ITEM#_______________
INSTALLATION
HC-821
IMPORTANT: DO NOT ATTACH FIXTURE DIRECTLY TO OUTLET
BOX.
STEP 1:
Secure mounting bar (A) to outlet box with outlet box screws (not
supplied). Thread nut (B) on nipple (C) so that three threads are
exposed above nut (B). Thread nipple (C) into mounting bar (A) and
secure with nut (B). Attach screw collar (E) to nipple (C).
STEP 2:
Using two pairs of pliers, open one link of chain (S) and connect it to
the fixture loop (I) at the top of the fixture.
STEP 3:
Lace wires up through chain (S) and pass wires through holes in
screw collar (E). We recommend lacing wire up through every other
link of chain (S).
STEP 4:
Note: If your fixture comes with (2) screw collar
rings. Select the one of your choice.
Slide the screw collar ring (G) and canopy (H), in that order, over
chain (S). Open one link on the top of the chain (S) and attach it
to the screw collar (E) which has been mounted to the ceiling nipple (C).
BE SURE TO CLOSE ALL CHAIN LINKS COMPLETELY.
STEP 5:
C. Fit a wire connector (not supplied) over the wires and screw the
connector clockwise until you feel a firmness.
D. Try gently to pull the connector off the wires. If you can pull the
connector off, carefully re-do steps B and C, as above and check
again for a firm connection.
E. Connect the fixture wire from group B to the white wire from the
outlet box in the same manner.
STEP 6:
GROUNDING INSTRUCTIONS: The green grounding screw (D) is
to be inserted into the hole with two raised dimples provided on the
mounting bar (A). Wrap the ground wire (F) from the fixture (if supplied)
and the ground wire from the outlet box (bare metal or green
insulated wire) around the green grounding screw (D) on the
mounting bar (A). If uninsulated wire is on the mounting bar (A),
connect the ground wire (F) from the fixture (if supplied) and the
outlet box to it using a small wire connector (not supplied).
NOTE: Underwriters Laboratories (U.L.) does not require all fixtures to
have ground wires. These fixtures still meet all U.L. specifications. The
listing mark of Underwriters on the product identifies products manufactured under its listing and Follow-Up Service Programs.
NEVER CONNECT GROUND WIRE TO BLACK OR WHITE
POWER SUPPLY WIRES.
FINAL ASSEMBLY
Make sure no bare wires can be seen outside wire connectors.
STEP 1:
A. Take note of the color of the wire(s) on your fixture. Identify
which group your fixture wire(s) falls into and connect the wires
according to the directions below:
After wires are connected, tuck them carefully inside outlet box and
then raise the canopy (H) against ceiling and screw the screw collar
ring (G) to the screw collar (E).
STEP 2:
Slip candle cover (J) over socket for each arm.
STEP 3:
Install lamps.
STEP 4:
Install shade (P) and / or glass over sockets and secure with retaining ring. (whichever is applicable)
GROUP A: CONNECT TO BLACK
HOUSE WIRE
GROUP B: CONNECT TO WHITE
HOUSE WIRE
BLACK
WHITE
*PARALLEL WIRE (ROUND & SMOOTH)
*PARALLEL WIRE (SQUARE & RIDGED)
*Note: When parallel wire is used, the tracer wire is square shaped
or ridged and less tracer wire is round in shape or smooth.
(Seen best when viewed from wire end.) To separate wires, grasp
the ends of each wire and pull apart.
B. Take your fixture wire(s) from group A and place evenly against
the black wire from the outlet box. DO NOT twist wires together
before using wire connectors.
CLEANING
To clean, wipe fixture with a soft cloth. Clean glass with a mild soap.
Do not use abrasive materials such as scouring pads or powders,
steel wool or abrasive paper.
ORDERING PARTS
Keep this sheet for future reference, and in case you need to order
replacement parts. All parts for this fixture can be ordered from place
of purchase. Be sure to use exact wording from illustration when
ordering parts.