Model:
PLFY-P125VBM-E
Job Name:
Schedule Reference:
Date:
SPECIFICATIONS
Capacity*
Cooling……………………..............................47,800 Btu/h
Heating……………………..............................54,600 Btu/h
Power
Power Source…………………….....220-240V, 1-phase, 50Hz
220V, 1-phase, 60Hz
GENERAL FEATURES
• Lightweight, low-profile compact design
• Customizable wide airflow pattern with adjustable vane control
through unit controller
• Auto wave airflow in heating mode—independent cycling of
horizontal and vertical vane positions for even heat distribution
• Four-speed fan settings
• Auto fan
• Corner-pocket design for simplified installation
• Built-in condensate lift mechanism; lifts to 26 in.
• Ventilation air intake supported
Power Consumption
Cooling………………………………..………………0.16 kW
Heating…………………………………..……………0.15 kW
Current
Cooling……...............................................................1.07 A
Heating……...............................................................1.00 A
Minimum Circuit Ampacity (MCA)………….…………....1.34 A
Maximum Overcurrent Protection (MOCP) Fuse..….......15 A
External Finish.................................Galvanized steel sheet
External Dimensions
Inches…………………….....11-3/4 h x 33-1/8 w x 33-1/8 d
mm…………………………………....298 h x 840 w x 840 d
Grille (PLP-6BA):
Inches…………………....1-3/8 h x 37-7/16 w x 37-7/16 d
mm……………………………...........35 h x 950 w x 950 d
Net Weight
Options
□□ Air Outlet Shutter Plate (2 pieces)….….……...PAC-SH51SP-E
□□ Multi-function Casement...…….….…………....PAC-SH53TM-E
□□ High-Efficiency Filter (MERV 10)…..……..…...PAC-SH59KF-E
□□ i-see Sensor Corner Panel..….……………..….PAC-SA1ME-E
□□ Automatic filter elevation panel...……............….…....PLP-6BAJ
□□ Wireless Signal Receiver....….………..……..….PAR-SA9FA-E
□□ Space panel…………………..................…...…PAC-SH48AS-E
□□ Duct flange for fresh air intake...……..............PAC-SH65OF-E
Unit………………..…...…………...................60 lbs. / 27 kg
Grille……..………..………..……..………......13 lbs. / 6 kg
Coil Type.………………..…...……………..............Cross Fin
Fan
(Aluminum Plate Fin and Copper Tube)
Type x Quantity………………............................Turbo Fan x 1
Airflow Rate(Low - Mid 1 - Mid 2 - High)
m3 / min…………………………………....22 - 25 - 28 - 30
L / s…………………………………....367 - 417 - 467 - 500
CFM………………........................777 - 883 - 989 - 1059
Standard Air Filter………….....Polypropylene Honeycomb
Refrigerant Piping Dimensions
R410A
Liquid (High Pressure)………………..3/8" / 9.52 mm Flare
Gas (Low Pressure)…………………5/8" / 15.88 mm Flare
* Cooling / Heating capacity indicated at the maximum value at operation
under the following conditions:
Cooling | Indoor: 81° F (27° C) DB / 66° F (19° C) WB
Cooling | Outdoor: 95° F (35° C) DB
Heating | Indoor: 68° F (20° C) DB
Heating | Outdoor: 45° F (7° C) DB / 43°F (6° C) WB
Notes:
Specifications are subject to change without notice.
© 2013 Mitsubishi Electric US, Inc.
Drainpipe Dimension………………...O.D. 1-1/4" / 32 mm
Sound Pressure Level
(Low - Mid 1 - Mid 2 - High)…………...35 - 38 - 41 - 43 dB(A)
2. EXTERNAL DIMENSIONS
PLFY-P125VBM-E – DIMENSIONS
Unit : mm
PLFY-P32,40,50,63,80,100,125VBM-E
20~45
Detail connecting of Branch duct(Both aspects)
810
Suspension bolt pitch
90
100
100
90
Cut out hole
(7.5)
605
620
+35
-5
24
350
[175
14-[2.8
Burring hole
Burring hole pitch
[150
Detail drawing of fresh air intake hole
Burring hole
3-[2.8
1
60
284
Drain pipe
PVC pipe: O.D. 32 (1-1/4")
377
B
A
Air intake
grille
597
190
Auto vane
(Air outlet)
Air intake hole
500
Air outlet hole
950
M
Ceiling
Auto-Grille
Air intake grille Up/down distance
83
36
500
Air outlet hole
36
950
Indoor unit
Ceiling
Grille
1500 mm
or more
1000 mm
or more
Indoor unit
3000 mm or
more
Obstacle
Floor
Emergency operation switch<Cooling>
and Emergency Up/Down switch<Up>
Emergency operation
switch<Heating>and
Emergency Up/Down switch<Down>
Models
1
2
PLFY-P32,40VBM-E
Refrigerant pipe···[ 6.35
Flared connection···1/4F
Refrigerant pipe ···[12.7
Flared connection···1/2F
PLFY-P50VBM-E
Refrigerant pipe
[6.35 /[9.52
Flared connection
1/4F / 3/8F (compatible)
Refrigerant pipe
[12.7
Flared connection
1/2F
PLFY-P100,125VBM-E
INDOOR UNITS
FORM# PLFY-P125VBM-E - 201306
Air intake grille
Accessory ··· Drain socket (I.D. 32 (1-1/4"))
1800mm or more
from floor
For high
attachment
PLFY-P63,80VBM-E
Specifications are subject to change without notice.
© 2013 Mitsubishi Electric US, Inc.
Ceiling
L.L Filter
Note 1. Please choose the Grille from a standard grille, Auto-Grille.
2. As for drain pipe, please use VP-25(O.D. [32 PVC TUBE).
Drain pump inclusion.
Raise is max 850mm from the ceiling.
3. As for suspension bolt, please use M10 or W3/8. (Procured at local site)
4. Electrical box may be removed for the service purpose.
Make sure to slack the electrical wire little bit for control/power wires connection.
5. The height of the indoor unit is able to be adjusted with the grille attached.
6. For the installation of the optional high efficiency filter or optional
multi-functional casement.
1) Requires E or more space between transom and ceiling for the installation.
2) Add 135 mm to the dimensions * marked on the figure.
3) The optional high efficiency filter becomes optional multi-functional
casement and concomitant use.
7. When installing the branch ducts, be sure to insulate adequately.
Otherwise condensation and dripping may occur.
(It becomes the cause of dew drops/Wear dew.)
8. As for necessary installation/service space, please refer to the left at figure.
Vane motor
83
In case of Auto-Grille : PLP-6BAJ
In case of wireless remote controller : PLP-6BALM
DEFROST/STAND BY lamp
Receiver
Operation lamp
M
M
[100
In case of standard grille : PLP-6BA
Drain hole
Drain pump clean hole
and Drain emergency
drainage hole
M
Cut out hole
*
*
597
Air intake hole
[125
*
35
Ceiling
Grille
)
17
Power supply wire,
Indoor unit/Outdoor unit
connecting wire entry
*
Control wire entry
*
+5
0
50~70
Suspension bolt
lower edge
156
105
140
170
PLFYVCM/VBM
*
*
(
Connected the attached
flexible pipe or socket.
I.D. 32 (1-1/4")
Keep approximatety
10 to 15 mm space
between unit ceilling
and ceilling slab.
2
*
Burring hole pitch
120°
120°
160
840
158
187.5
20~45
Suspension bolt
M10 or W3/8
*
Cut out hole
160
D
C
90
Branch duct hole
(7.5)
840
For MA-Remote controller
terminal block
860~910
Suspension bolt pitch
Power supply
terminal block
Branch duct hole
Ceiling hole
* 155
160
Transmission terminal block
150
70°
100
160
20~45
Fresh air
intake hole
167
860~910
130
Ceiling hole
20~45
Max. 4.0m
Model:
G9
R410A Data
Refrigerant pipe···3/8F
Flared connection···[9.52
A
B
C
E
241 258 87 78 400
Refrigerant pipe···[15.88
Flared connection···5/8F
Refrigerant pipe
[15.88
Flared connection
5/8F
D
80 74
77
85
281 298
81 440
1 - 130
1340 Satellite Boulevard
Suwanee, GA 30024
Tele: 678-376-2900 • Fax: 800-889-9904
Toll Free: 800-433-4822
www.mehvac.com