Symmons 3606-H321-V-STN Installation Guide

Add to My manuals
7 Pages

advertisement

Symmons 3606-H321-V-STN Installation Guide | Manualzz

3603-H321-V-TRM, 3605-H321-V-TRM, 3606-H321-V-TRM

Duro™ Trim Series

Operation & Maintenance Manual

Model Numbers Specification

3603-H321-V-TRM

Valve Trim with Hand Shower

3605-H321-V-TRM

Shower Trim with Hand Shower

3606-H321-V-TRM

Tub/Shower Trim with Hand Shower

Options/Modifications

-1.5

1.5 gpm (5.7 L/min) flow restrictor

-2.0

2.0 gpm (7.6 L/min) flow restrictor

-LW

Wide lever handle (chrome finish only)

-SS

Slip spout on any tub/shower unit

Tub/shower trim with hand shower and lever handle includes wall connection, 30” slide bar, in-line vacuum breaker, flexible metal hose, non-diverter tub spout,

1 mode hand shower and 1 mode showerhead with standard 2.5 gpm (9.5 L/min) flow restrictor. Shower trim with hand shower and lever handle includes all of the above less non-diverter tub spout. Valve trim with hand shower and lever handle includes all of the above less non-diverter tub spout and 1 mode showerhead.

Components made from metal and nonmetallic materials plated in standard polished chrome finish.

Compliance

-ASME A112.18.1/CSA B125.1

Warranty

Limited Lifetime - to the original end purchaser in consumer/residential installations.

5 Years - for industrial/commercial installations.

Refer to www.symmons.com/warranty for complete warranty information.

Note: Append appropriate -suffix to model number.

Dimensions

AA

BB

DD

CC EE

FF

GG

II

HH

LL

PP

NN

JJ

KK

RR

QQ

Notes:

1) All dimensions measured from nominal rough-in (see O as reference).

2) Dimensions subject to change without notice.

OO

P

Q

R

L

M

N

O

A

B

C

D

H

I

J

E

F

G

K

Measurements

Ø 2 1/4”, 57 mm

5 7/8”, 149 mm

6”, 152 mm right or left

Male 1/2” NPT thread must be recessed 1/4” from finished wall

Ref. 77”, 1956 mm

4 7/8”, 123 mm

5”, 127 mm

7 1/2”, 191 mm

10”, 254 mm

Ø 2 1/2”, 64 mm

(3606)

Ref. 32”, 813 mm

(3603, 3605)

Ref. 42”, 1067 mm

12”, 305 mm

3 3/16”, 81 mm

3 7/16”, 87 mm

Rough-in

2 3/8” ± 1/2”, 60 mm ± 13 mm

5 1/4”, 133 mm

7”, 178 mm

1/2” NPT

2

Parts Breakdown

J

J

K

K

A

L

B

F

Q

G

G

S

S

C

E

R

H

M

D

N

I

O

P

*Note: Apply a bead of silicone around the perimeter of the escutcheons after installing trim flush with wall. Leave opening on bottom of escutcheons for weep hole.

Item

Replacement Parts

Description

I

N

O

P

C

D

A

Q

B

In-line Vacuum

Breaker & 60” Hose

Wall Elbow

Hand Shower

Slide Bar

Assembly

Shower Arm

Flange

S

G

L*

M

S

E

F*

G

H

Showerhead

Diverter Escutcheon

Screws

Mounting Plate

Gasket

Screws

Escutcheon

Mounting Plate

Gasket

J Handle Assembly

K Dome Cover

R Tub Spout

Part Number

EF-104

EF-105

EF-100

SC-115

300S

362SH

T-525-NS

T-470-NS-K009

T-617

RTS-037

067

Notes:

1) Append -STN to part number for Satin Nickel finish.

2) Append -1.5 or -2.0 to showerhead or hand shower for low flow.

Tools Required for Installation

Adjustable wrench

Allen wrench

(1/8”)

Phillips head screwdriver

Plumber tape

Power drill

Silicone

3

Installation

Note:

For valve body installation, please see valve body installation guides.

1) Install small plastic mounting plate (H) to diverter valve (3506 diverter valve = 4-460E-BODY,

3505 diverter valve =

4-458E-BODY) and large plastic mounting plate (M) to shower valve

(4000-BODY). Secure each with two screws (G).

3) Attach shower escutcheon (L) to large plastic mounting plate (M).

L

M

Note: Tabs should snap into place .

1

G

H

4) Install dome covers (K) to valves by turning clockwise.

5) Install diverter handle (3605 and

3606 only) (J) and shower handle (J) to valves. Secure handles by tightening set screws.

J

1

1

J

M

2

1

K

1

G

2

Note: Handles should be facing the

6 o'clock position.

6) Install tub spout (R) to stub out pipe. Turn clockwise to secure.

2) Attach diverter escutcheon (F) to small plastic mounting plate (H).

1

K 2

1

F

R

H

2

Note: Tabs should snap into place .

4

Installation

7a) Dry Wall Option: Remove upper and lower caps (N) from slide bar brackets. Place slide bar (P) into desired position. Using brackets as a guide, carefully drill 3/16" holes into wall. Remove slide bar and install anchors.

7b) Stud Option: Remove upper and lower caps (N) from slide bar brackets. Place slide bar (P) into desired position. Using brackets as a guide, carefully drill 1/8" pilot holes into stud.

8) With slide bar (P) in position, secure to wall using screws (O).

Replace upper and lower caps (N) onto slide bar brackets.

N

2

N

1

N

1

O

4

2

2

P P

P

P

2

2

N

1

N

1

4

3

3

Notes: Make sure that slide bar holes and bracket holes are aligned before drilling.

Before drilling bottom hole, make sure slide bar is plumb.

Notes: Make sure that slide bar holes and bracket holes are aligned before drilling.

Before drilling bottom hole, make sure slide bar is plumb.

1

N

2

5

Installation

9) Install wall elbow (B) to stub out pipe. Tighten set screw to secure.

B

1

2

10) Attach shower arm (C) and flange (D) to vertical shower pipe turning clockwise to tighten.

11) Install showerhead (E) to shower arm (C). Turn clockwise to tighten.

12) Attach large end of hand shower hose (Q) to hand shower wand

(I). Attach small end of hand shower hose (Q) to in-line vacuum breaker (A). Connect inline vacuum breaker to wall elbow (B). Turn clockwise to tighten.

C

1

I

E

2

2 1

Q

B

3

1

A

Q

4

2

D

C

6

Operation & Maintenance

Temperature Control

1) Turn shower handle counterclockwise approximately

1/4 turn to put valve in cold position.

Diverter Control

1) Diverter handle facing straight down is for diverter function 1.

2) Turn shower handle counterclockwise approximately

1/2 turn to put valve in warm position.

2) 3605: Turn diverter handle counterclockwise one full revolution for diverter function 2.

3606: Turn diverter handle counterclockwise 1/4 turn for diverter function 2.

3605-H321-V-CYL-B-TRM 3606-H321-V-CYL-B-TRM

3) Turn shower handle counterclockwise approximately

3/4 turn to put valve in hot position.

3) 3606-TRM: Turn diverter handle counterclockwise 3/4 turn for diverter function 3.

Finish is spotting.

Troubleshooting Chart

Elements in water supply may cause water staining on finish.

Clean finished trim area with a soft cloth using mild soap and water or a non-abrasive cleaner and then quickly rinse with water.

Symmons Industries, Inc. ■ 31 Brooks Drive ■ Braintree, MA 02184 ■ Phone: (800) 796-6667 ■ Fax: (800) 961-9621

Copyright © 2015 Symmons Industries, Inc.

www.symmons.com

[email protected]

ZV-3017 REV 0

100314

advertisement

Related manuals

advertisement