advertisement
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]
MileSeey S3 series handheld laser distance meter user guide
1. Overview
MileSeey S3 series product measures up to 100m, integrates tilt sensor and full color screen, is specially for professional users.
Initial adoption of li-ion battery, which greatly enhances usage life and can last for several years. In addition, it is more green. mOS V1.0, is an innovated and patent measuring system, which has vivid colorful screen, strong interactive interface, and has professional measuring functions. The various supplement functions and unique personal setting providing unexpected measuring experience and fun.
The perfect combination of ergonomic design and fashion provides amazing functions and experience. The product leads to a new era of professional measurement.
2. Start-up&Shut-down
1) Inserting/replacing batteries
Remove battery compartment lid by pressing it lightly, insert the provided Li-ion battery and close the cover.
Remove the batteries before any long period of non-use to avoid the danger of corrosion.
Your strongly recommended to user li-ion batteries which is produced by original laser meter producer.
2) Start-up
Press key to start-up, and directly go to the interface of single measuring(see figure).
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]
3) Manual Shut-down
Pressing this button for longer switches the instrument off.
4) Auto Shut-down
The instrument switches off automatically after three minutes of inactivity.
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]
3. Button functions
1.Area/Volume/ Pythagoras
2.Plus/Go Up
3. Tilt/ triangle
4.Confirmation
5.Go Right
6.Saving/Historical data
7. Power On/Measuring (On/Single/continuous meas)
8.Menu/Power Off
9.Minus/Go Down
10. Reference
11.Go Left
12. Clear/Cancel
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]
4. Display screen general view
The graphics screen of the measurement window is split into different areas. Top second screen is the measurement functional field, which contains the currently selected measuring program. Just to the left/right appears the program submenu, which shows the measuring programs that can be selected by pressing the same key the required number of times. The measurement field contains the individual measurements of the measuring program with reference to a series of separate distance measurements. Three lines are provided for last measurement data. A horizontal line separates the measurement field and the result bar from one another.
1 Status bar with (time, battery status, bubble)
2 Program selection with measurement instructions
3. Status of measurement, (Reference, laser on)
3 Measurement field
4 Result bar
5 Measurement type
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]
5. Measuring
In measuring mode, user can press to delete the current measured data and re-measure.
1) Single Measuring
Following 3 entries lead to single measurement function (see figure)
Press key to start-up, and directly go to the interface of single measuring
It will be back to this mode after completing measurement every time.
User will be back to single measuring mode by press one or more times in menu setting interface.
Press to activate the laser. Press again to trigger the distance measurement. The result is displayed immediately.
2) Continuous Measuring
Press and hold down the key until hear "beep" to activate continuous measurement.
This function enable user to measure the minimum or maximum distance from a fixed
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]
measuring point. User can press or to stop the function, and The values for maximum and minimum distances are shown in the display as well as the last measured value in the summary line.
3) Area Measuring
Press once, the symbol appears in function filed of display.
Press to take the first distance measurement (e.g. Length).
Press again to take the second distance measurement (e.g. width).
The results of length, width, perimeter and area are displayed in the historical data line in order.
4) Volume Measuring
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]
Press twice, the symbol volume function activated as well.
appears in the function field on the display, and the
Press to take the first length measurement (e.g. Length). Next get the width, then heights, the final result is displayed in the summary line.
Press and to display additional room information such as ceiling/floor, surface area of the walls, circumference.
5) Single Pythagoras
Press three times to activate the function,symbol appears in the function field on the display as following to take No. 1, and No. 2 length, the result is displayed on the summary line. Press to delete any measured length and then press to re-measure.
6) Double Pythagoras
Press four times to activate the function, the symbol as following to take No.1,2 and 3 length,
display in function field
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]
the height is displayed on the summary line. Press to find additoinal information
6. Tilt measurement
1) Tilt measurement
Press button,the symbol the
inclination
and the distance.
appears in the function field, press to take
The inclination sensor measures tilts between ± 45°.
During the measurement of tilt, the instrument should be held without transverse
tilt, as far as possible within ± 10°. The accuracy is 0.3°.
2) Auto horizontal measurement
Press twice ,the symbol appears in the functional field. Press button to measure angel and distance, The summary line displays the result as the direct horizontal distance
3) Auto height measurement
Press third times ,the symbol appears in the functional field. Press button to take both sloping sides, the vertical height is displayed in the summary line.
4) Triangular measurement
Press four times ,the symbol appears in the functional area. Press button to take 3 sloping sides respectively, the area is displayed in the summary line. Press to find out each angel of the Triangular and circumference.
7. Edit Measuring data Function
Note: this function is only enabled in measurement mode and at least a measured data display in the screen.
1) Select data
Press or to select measuring type in measuring process file (left handside of the screen) , press to locate the corresponding data, the data frame turning yellow indicates the data has been selected.
2) Re-measure:
When this data was selected, press to re-measure the distance till the result is satisfied. Press or return to measurement interface,
3) Adjust measurement result:
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]
When this data was selected, press , the cursor appears in the measurement type field, press or move the cursor to select the digit of data, and press or to increase or reduce the value, press to save and return to measurment interface, or press cancel the modification and return the previous data.
4) Addition / subtraction:
When this data was selected, press to appears in the measuremnt type field, press
the next measurement is added to the previous, In the same approach, Press , the The next measurement is subtracted from the previous one. press to save and return to measurment interface, or press cancel the modification and return the previous data.
8. Data locking:
1)Data locking introduction:
Usually the instrument keeps and deletes the measurement data in sequence of first in first out. The first in value will be deleted if total measurement data reach the maximum storage (eg.30 records). This function enable user to save data permanently except user deletes it manually from memory.
2) Lock data:in mode of measuring, when measuring, select data, press , the dialog box pop up user to select “save” button, then press “ ” to lock the data, return to measurement interface.
3) Lock/unlock data:in Historical record function: In history data interface, move cursor to navigate the data, then to lock it. And press again to unlock the data.
9. Historical record:
1) Historical record view:
Press to call up the function, press or to select the measurment type, sorting by which, all of the data record displays in sequnce of created time.
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]
2) View detail record
Press to read detail informaton of this record, including data type
(locked/unlocked) ,no.of order all data, date, time, measurement function, measurement types , corresponding result, additional information,
For example, in function of volume measuemnt, additional infomration such as ceiling/floor area , surface area of the walls , circumference displays.
3) Historical record delete
Batch records delete:
When cursor select one of measurement type, Press
, then press to delete all the historical records belonging to this measurement type.
Single record delete:
Press or to browse the record then Press , and press to delete the record.
Press or to browse the record then repeatedly press to loock and unlock the
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]
record.
.
10. System settings:
Press out setting type, press to be next sub-setting function.
enter main screen, press or to move up and down find
Five kinds of funcitons proivded, Tools, Personal Set ,Set, others which will be addressed below,
10.1 Tools
1) Timer
In screen of Tools-> Timer,
The unit of delay time is second, press or move the cursor to select the digit of data, and press or to increase or reduce the value, press to save and return to upper interface, or press cancel the modification and return to the previous data.
Press to call up the function, the remaining seconds until measurement (e.g. 10, 9,
8...) are displayed in a countdown. The last 5 seconds are counted down with a beep.
After the last beep the measurement is taken and the value is displayed.
2) Staking Out
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]
In screen of Tools-> Staking out press or move the cursor to select the digit of data, and press or to increase or reduce the value, press to save and return to upper interface, or press
cancel the modification and return to the previous data.
Pressing the button starts the laser measurement. The display shows required stake out distance in the summary line between the stake out point and the instrument (rear reference). If the instrument moved slowly along the stake out line the displayed distance decreases. The instrument starts to beep at a distance of 0.1m from the next stake out point. The arrows in the display indicate in which direction the Meter needs to be moved in order to achieve the defined distance. As soon as the staking out point is reached, the symbol appears in the display.
3) Level
In screen of Tools-> Level,
3 mercury columns represents X, y and 45 axis, the value display when meter is rotated.
4) Thermometer
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]
In screen of Tools-> thermometer
The thermometer records the current temperature of meter in the environment. Both
Fahrenheit and degree Celsius are displayed in the screen.
5) Export
In screen of Tools-> Export
Real time Export :in the Connection between meter and terminals through data cable, when user press to take single measurement date, the data is automatically transmited to terminals without installing any additional software.
Battch Export:
1. Establish Connection between meter and terminals through data cable
2. Open editors like EXCEL and move the cursor where you want to start
3. Press OK button to activate export function till finished
Only U series’ have such function, A series’ haven't such application.
Using this function, not need to install specified software, Excel file is applicable.
10.2 Personal Set
1) Offset
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]
In screen of Personal setting-> Offset, press or move the cursor to select the digit of data, and press or to increase or reduce the value, press to save and return to previous interface, or press cancel the modification and return to the previous data.
An offset adds or subtracts a specified value automatically to or from all measurements.
2) Brightness
In screen of Personal setting-> Brightness,
The brightness of screen could be adjusted in 5 levels by pressing or to be lighter or darker.
3) Time Format
In screen of Personal setting-> time format
Three kinds of time format could be selected by pressing or , . press to save and return to upper interface, or press cancel the modification and return to the previous data.
4) G-Sensor
In screen of Personal setting-> G-Sensor
You can calibrate the tilt sensor in the device. Calibration requires two measurements on a level surface.
Put on the device on the level surface, press
Rotate the device horizontally through 180°, press ,
The tilt sensor is calibrated.
5) Language
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]
In screen of Personal setting-> Language
Press or to select the language, press to save and return to upper interface, or press cancel the modification and return to the previous language. English is default language.
10.3 Set
1) Measurement Unit
In screen of Setting-> Measurement unit
4 type of units can be selected as Meter, Feet, Inch, Feet&Inch.
Press or to select the unit; press to save and return to upper interface, or press cancel the modification and return to the previous data.
2) Angle Unit
In screen of Setting-> Angle Unit
Two kinds of angel unit available +/- 0.0° or 0.00%
Press or to select the unit; press to save and return to upper interface, or press cancel the modification and return to the previous data.
3) Beep
In screen of Setting-> Beep,
Press or to select ON or OFF the beep, press to save and return to upper interface, or press cancel the modification and return to the previous data.
4) Time Set
In screen of Setting-> Time set press or move the cursor to select the digit of data, and press or to increase or reduce the value, press to save and return to upper interface, or press
cancel the modification and return the previous data.
5) Bubble
In screen of Setting-> Bubble
Press or to select ON or OFF the bubble which is display in the status filed in the screen, press to save and return to upper interface, or press cancel the
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]
modification and return to the previous data.
10.4 Others
1) About us
In screen of Setting-> Others>About us
Software information display:
Version
Copyright,
Press or to go back to upper interface
2) Factory Reset
In screen of Setting-> Others> Factory Reset
Press
, the device returns to the factory settings and stack and memory are deleted.
3) Reset
In screen of Setting-> Others> Reset
Press
, the device returns to the factory settings but the records are still in the memory.
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]
11. Error Code
Code Cause
156 Transverse tilt greater than
10°
160 Main tilt direction, angle too high (> 45°)
Corrective Measure
Hold the instrument without any transverse tilt
Measure angle up to max. ± 45°
162 The calibration has not been accomplished on a leveled surface
Calibrate the device on an absolute Horizontal leveled surface.
204 Calculation error
208 Temperature too high
220 Battery too low
Refer to user menu, repeat the procedures
Cool down
Recharge battery
252
253
Temperature too High
Temperature too Low
255 Receiver signal too weak, measurement time too long
256 Received signal too strong
Cool down instrument
Warm up instrument
Use target plate or change a good refection
Error Hardware error and uncertainty error
Target too reflective use target plate or do not aim at strong light objective
Switch on/off the device several times. If the symbol still appears, then your instrument is defective. Please call your dealer for assistance
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]
12. Measurement steps
Function Icon
Measurement steps
Area
Volume
Pyth- agorean1
Pyth- agorean2
Inclination measurement
Auto Horizontal
Auto Heights
Triangular
Red side measuring
Green side result
1 2 3
Staking out
Additional
Information
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]
13. Technical specifications
Functional Spec
Typical measuring accuracy
Measurement range
Measuring units
Laser Class
Display
Tilt measurements
Tilt sensor Accuracy
Battery
Battery life
Horizontal measurement
Angle measurement using tilt sensor(± 45°)
Staking out function
Recall last values
Buzzer indication
Dust Protect/Splash proof
Operating Temperature
Storage Temperature
Data Interface USB
Auto instrument switch-off
Dimension
Weight
YES
30
YES
IP54
0°C to 40°C
-10°C to 60°C
No after 3 min
115x48x35mm
105g
S3A
±
1.5 mm
S3U
±
1.5 mm
100m
M/in/ft
Class 2M
100m
M/in/ft
Class 2M
2 Inch Full color screen 2 Inch Full color screen
YES YES
±
0.3°
±
0.3°
Li-ion battery/1200mAh Li-ion battery/1200mAh
15,000 times
YES
15,000 times
YES
YES YES
YES
1000
YES
IP54
0°C to 40°C
-10°C to 60°C
YES after 3 min
115x48x35mm
106g
Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]
14. Package
Porch
Li-ion battery
Power Charger,
Data Cable
15. Contact
ShenZhen MileSeey Technology Co.,Ltd
ADD: F/6, Building 9, Zhongguan Honghualing Industrial South Park II,1213 Liuxian Ave,
Taoyuan Street,Nanshan District, Shenzhen, 518055, P.R. China.
TEL:+86-755-86329055
FAX:+86-755-86701592
Website: www.mileseey.net
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project