MileSeey S3 series handheld laser distance meter user guide

Add to my manuals
20 Pages

advertisement

MileSeey S3 series handheld laser distance meter user guide | Manualzz

Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

MileSeey S3 series handheld laser distance meter user guide

1. Overview

MileSeey S3 series product measures up to 100m, integrates tilt sensor and full color screen, is specially for professional users.

Initial adoption of li-ion battery, which greatly enhances usage life and can last for several years. In addition, it is more green. mOS V1.0, is an innovated and patent measuring system, which has vivid colorful screen, strong interactive interface, and has professional measuring functions. The various supplement functions and unique personal setting providing unexpected measuring experience and fun.

The perfect combination of ergonomic design and fashion provides amazing functions and experience. The product leads to a new era of professional measurement.

2. Start-up&Shut-down

1) Inserting/replacing batteries

Remove battery compartment lid by pressing it lightly, insert the provided Li-ion battery and close the cover.

Remove the batteries before any long period of non-use to avoid the danger of corrosion.

Your strongly recommended to user li-ion batteries which is produced by original laser meter producer.

2) Start-up

Press key to start-up, and directly go to the interface of single measuring(see figure).

Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

3) Manual Shut-down

Pressing this button for longer switches the instrument off.

4) Auto Shut-down

The instrument switches off automatically after three minutes of inactivity.

Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

3. Button functions

1.Area/Volume/ Pythagoras

2.Plus/Go Up

3. Tilt/ triangle

4.Confirmation

5.Go Right

6.Saving/Historical data

7. Power On/Measuring (On/Single/continuous meas)

8.Menu/Power Off

9.Minus/Go Down

10. Reference

11.Go Left

12. Clear/Cancel

Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

4. Display screen general view

The graphics screen of the measurement window is split into different areas. Top second screen is the measurement functional field, which contains the currently selected measuring program. Just to the left/right appears the program submenu, which shows the measuring programs that can be selected by pressing the same key the required number of times. The measurement field contains the individual measurements of the measuring program with reference to a series of separate distance measurements. Three lines are provided for last measurement data. A horizontal line separates the measurement field and the result bar from one another.

1 Status bar with (time, battery status, bubble)

2 Program selection with measurement instructions

3. Status of measurement, (Reference, laser on)

3 Measurement field

4 Result bar

5 Measurement type

Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

5. Measuring

In measuring mode, user can press to delete the current measured data and re-measure.

1) Single Measuring

Following 3 entries lead to single measurement function (see figure)

Press key to start-up, and directly go to the interface of single measuring

It will be back to this mode after completing measurement every time.

User will be back to single measuring mode by press one or more times in menu setting interface.

Press to activate the laser. Press again to trigger the distance measurement. The result is displayed immediately.

2) Continuous Measuring

Press and hold down the key until hear "beep" to activate continuous measurement.

This function enable user to measure the minimum or maximum distance from a fixed

Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

measuring point. User can press or to stop the function, and The values for maximum and minimum distances are shown in the display as well as the last measured value in the summary line.

3) Area Measuring

Press once, the symbol appears in function filed of display.

Press to take the first distance measurement (e.g. Length).

Press again to take the second distance measurement (e.g. width).

The results of length, width, perimeter and area are displayed in the historical data line in order.

4) Volume Measuring

Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

Press twice, the symbol volume function activated as well.

appears in the function field on the display, and the

Press to take the first length measurement (e.g. Length). Next get the width, then heights, the final result is displayed in the summary line.

Press and to display additional room information such as ceiling/floor, surface area of the walls, circumference.

5) Single Pythagoras

Press three times to activate the function,symbol appears in the function field on the display as following to take No. 1, and No. 2 length, the result is displayed on the summary line. Press to delete any measured length and then press to re-measure.

6) Double Pythagoras

Press four times to activate the function, the symbol as following to take No.1,2 and 3 length,

display in function field

Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

the height is displayed on the summary line. Press to find additoinal information

6. Tilt measurement

1) Tilt measurement

Press button,the symbol the

inclination

and the distance.

appears in the function field, press to take

The inclination sensor measures tilts between ± 45°.

During the measurement of tilt, the instrument should be held without transverse

tilt, as far as possible within ± 10°. The accuracy is 0.3°.

2) Auto horizontal measurement

Press twice ,the symbol appears in the functional field. Press button to measure angel and distance, The summary line displays the result as the direct horizontal distance

3) Auto height measurement

Press third times ,the symbol appears in the functional field. Press button to take both sloping sides, the vertical height is displayed in the summary line.

4) Triangular measurement

Press four times ,the symbol appears in the functional area. Press button to take 3 sloping sides respectively, the area is displayed in the summary line. Press to find out each angel of the Triangular and circumference.

7. Edit Measuring data Function

Note: this function is only enabled in measurement mode and at least a measured data display in the screen.

1) Select data

Press or to select measuring type in measuring process file (left handside of the screen) , press to locate the corresponding data, the data frame turning yellow indicates the data has been selected.

2) Re-measure:

When this data was selected, press to re-measure the distance till the result is satisfied. Press or return to measurement interface,

3) Adjust measurement result:

Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

When this data was selected, press , the cursor appears in the measurement type field, press or move the cursor to select the digit of data, and press or to increase or reduce the value, press to save and return to measurment interface, or press cancel the modification and return the previous data.

4) Addition / subtraction:

When this data was selected, press to appears in the measuremnt type field, press

the next measurement is added to the previous, In the same approach, Press , the The next measurement is subtracted from the previous one. press to save and return to measurment interface, or press cancel the modification and return the previous data.

8. Data locking:

1)Data locking introduction:

Usually the instrument keeps and deletes the measurement data in sequence of first in first out. The first in value will be deleted if total measurement data reach the maximum storage (eg.30 records). This function enable user to save data permanently except user deletes it manually from memory.

2) Lock data:in mode of measuring, when measuring, select data, press , the dialog box pop up user to select “save” button, then press “ ” to lock the data, return to measurement interface.

3) Lock/unlock data:in Historical record function: In history data interface, move cursor to navigate the data, then to lock it. And press again to unlock the data.

9. Historical record:

1) Historical record view:

Press to call up the function, press or to select the measurment type, sorting by which, all of the data record displays in sequnce of created time.

Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

2) View detail record

Press to read detail informaton of this record, including data type

(locked/unlocked) ,no.of order all data, date, time, measurement function, measurement types , corresponding result, additional information,

For example, in function of volume measuemnt, additional infomration such as ceiling/floor area , surface area of the walls , circumference displays.

3) Historical record delete

Batch records delete:

When cursor select one of measurement type, Press

, then press to delete all the historical records belonging to this measurement type.

Single record delete:

Press or to browse the record then Press , and press to delete the record.

Press or to browse the record then repeatedly press to loock and unlock the

Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

record.

.

10. System settings:

Press out setting type, press to be next sub-setting function.

enter main screen, press or to move up and down find

Five kinds of funcitons proivded, Tools, Personal Set ,Set, others which will be addressed below,

10.1 Tools

1) Timer

In screen of Tools-> Timer,

The unit of delay time is second, press or move the cursor to select the digit of data, and press or to increase or reduce the value, press to save and return to upper interface, or press cancel the modification and return to the previous data.

Press to call up the function, the remaining seconds until measurement (e.g. 10, 9,

8...) are displayed in a countdown. The last 5 seconds are counted down with a beep.

After the last beep the measurement is taken and the value is displayed.

2) Staking Out

Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

In screen of Tools-> Staking out press or move the cursor to select the digit of data, and press or to increase or reduce the value, press to save and return to upper interface, or press

cancel the modification and return to the previous data.

Pressing the button starts the laser measurement. The display shows required stake out distance in the summary line between the stake out point and the instrument (rear reference). If the instrument moved slowly along the stake out line the displayed distance decreases. The instrument starts to beep at a distance of 0.1m from the next stake out point. The arrows in the display indicate in which direction the Meter needs to be moved in order to achieve the defined distance. As soon as the staking out point is reached, the symbol appears in the display.

3) Level

In screen of Tools-> Level,

3 mercury columns represents X, y and 45 axis, the value display when meter is rotated.

4) Thermometer

Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

In screen of Tools-> thermometer

The thermometer records the current temperature of meter in the environment. Both

Fahrenheit and degree Celsius are displayed in the screen.

5) Export

In screen of Tools-> Export

Real time Export :in the Connection between meter and terminals through data cable, when user press to take single measurement date, the data is automatically transmited to terminals without installing any additional software.

Battch Export:

1. Establish Connection between meter and terminals through data cable

2. Open editors like EXCEL and move the cursor where you want to start

3. Press OK button to activate export function till finished

Only U series’ have such function, A series’ haven't such application.

Using this function, not need to install specified software, Excel file is applicable.

10.2 Personal Set

1) Offset

Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

In screen of Personal setting-> Offset, press or move the cursor to select the digit of data, and press or to increase or reduce the value, press to save and return to previous interface, or press cancel the modification and return to the previous data.

An offset adds or subtracts a specified value automatically to or from all measurements.

2) Brightness

In screen of Personal setting-> Brightness,

The brightness of screen could be adjusted in 5 levels by pressing or to be lighter or darker.

3) Time Format

In screen of Personal setting-> time format

Three kinds of time format could be selected by pressing or , . press to save and return to upper interface, or press cancel the modification and return to the previous data.

4) G-Sensor

In screen of Personal setting-> G-Sensor

You can calibrate the tilt sensor in the device. Calibration requires two measurements on a level surface.

Put on the device on the level surface, press

Rotate the device horizontally through 180°, press ,

The tilt sensor is calibrated.

5) Language

Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

In screen of Personal setting-> Language

Press or to select the language, press to save and return to upper interface, or press cancel the modification and return to the previous language. English is default language.

10.3 Set

1) Measurement Unit

In screen of Setting-> Measurement unit

4 type of units can be selected as Meter, Feet, Inch, Feet&Inch.

Press or to select the unit; press to save and return to upper interface, or press cancel the modification and return to the previous data.

2) Angle Unit

In screen of Setting-> Angle Unit

Two kinds of angel unit available +/- 0.0° or 0.00%

Press or to select the unit; press to save and return to upper interface, or press cancel the modification and return to the previous data.

3) Beep

In screen of Setting-> Beep,

Press or to select ON or OFF the beep, press to save and return to upper interface, or press cancel the modification and return to the previous data.

4) Time Set

In screen of Setting-> Time set press or move the cursor to select the digit of data, and press or to increase or reduce the value, press to save and return to upper interface, or press

cancel the modification and return the previous data.

5) Bubble

In screen of Setting-> Bubble

Press or to select ON or OFF the bubble which is display in the status filed in the screen, press to save and return to upper interface, or press cancel the

Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

modification and return to the previous data.

10.4 Others

1) About us

In screen of Setting-> Others>About us

Software information display:

Version

Copyright,

Press or to go back to upper interface

2) Factory Reset

In screen of Setting-> Others> Factory Reset

Press

, the device returns to the factory settings and stack and memory are deleted.

3) Reset

In screen of Setting-> Others> Reset

Press

, the device returns to the factory settings but the records are still in the memory.

Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

11. Error Code

Code Cause

156 Transverse tilt greater than

10°

160 Main tilt direction, angle too high (> 45°)

Corrective Measure

Hold the instrument without any transverse tilt

Measure angle up to max. ± 45°

162 The calibration has not been accomplished on a leveled surface

Calibrate the device on an absolute Horizontal leveled surface.

204 Calculation error

208 Temperature too high

220 Battery too low

Refer to user menu, repeat the procedures

Cool down

Recharge battery

252

253

Temperature too High

Temperature too Low

255 Receiver signal too weak, measurement time too long

256 Received signal too strong

Cool down instrument

Warm up instrument

Use target plate or change a good refection

Error Hardware error and uncertainty error

Target too reflective use target plate or do not aim at strong light objective

Switch on/off the device several times. If the symbol still appears, then your instrument is defective. Please call your dealer for assistance

Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

12. Measurement steps

Function Icon

Measurement steps

Area

Volume

Pyth- agorean1

Pyth- agorean2

Inclination measurement

Auto Horizontal

Auto Heights

Triangular

Red side measuring

Green side result

1 2 3

Staking out

Additional

Information

Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

13. Technical specifications

Functional Spec

Typical measuring accuracy

Measurement range

Measuring units

Laser Class

Display

Tilt measurements

Tilt sensor Accuracy

Battery

Battery life

Horizontal measurement

Angle measurement using tilt sensor(± 45°)

Staking out function

Recall last values

Buzzer indication

Dust Protect/Splash proof

Operating Temperature

Storage Temperature

Data Interface USB

Auto instrument switch-off

Dimension

Weight

YES

30

YES

IP54

0°C to 40°C

-10°C to 60°C

No after 3 min

115x48x35mm

105g

S3A

±

1.5 mm

S3U

±

1.5 mm

100m

M/in/ft

Class 2M

100m

M/in/ft

Class 2M

2 Inch Full color screen 2 Inch Full color screen

YES YES

±

0.3°

±

0.3°

Li-ion battery/1200mAh Li-ion battery/1200mAh

15,000 times

YES

15,000 times

YES

YES YES

YES

1000

YES

IP54

0°C to 40°C

-10°C to 60°C

YES after 3 min

115x48x35mm

106g

Cosinus Messtechnik GmbH - Lise-Meitner-Straße 6 - 85521 Ottobrunn - www.cosinus.de - Tel: 089/66559410 - Fax: 089/66559430 - [email protected]

14. Package

Porch

Li-ion battery

Power Charger,

Data Cable

15. Contact

ShenZhen MileSeey Technology Co.,Ltd

ADD: F/6, Building 9, Zhongguan Honghualing Industrial South Park II,1213 Liuxian Ave,

Taoyuan Street,Nanshan District, Shenzhen, 518055, P.R. China.

TEL:+86-755-86329055

FAX:+86-755-86701592

Website: www.mileseey.net

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals

Download PDF

advertisement