- Sports & recreation
- Fitness, gymnastics & weight training
- Treadmills
- GE Medical Systems
- T-2100
- User manual
GE Medical Systems T-2100 Operator's Manual
Add to My manuals28 Pages
GE Medical Systems T-2100 treadmill offers various capabilities, including analyzing user's cardiovascular performance, providing them with real-time feedback and monitoring their performance. It can be utilized both professionally in clinical settings and at home to assist in cardiac rehabilitation and fitness goals, promoting a healthier lifestyle.
advertisement
T-2100 Treadmill
Operator's Manual
2021403-026 Revision B
NOTE
The information in this manual only applies to the T-2100 Treadmill. It does not apply to earlier product versions. Due to continuing product innovation, specifications in this manual are subject to change without notice.
CardioSoft, MAC and CASE are trademarks owned by GE Medical Systems Information Technologies
GmbH, a General Electric Company going to market as GE Healthcare.
© 2005, 2007 General Electric Company. All rights reserved.
T-2 T-2100 Treadmill 2021403-026B
15 August 2007
CE Marking Information
CE Marking Information
Compliance
NOTE
The CE mark information is part of the operator manual and is applicable for all products marked and delivered by GE Medical
Systems Information Technologies in the European community.
The T-2100 Treadmill bears CE mark CE-0459 indicating its conformity with the provisions of the Council Directive 93/42/EEC concerning medical devices and fulfills the essential requirements of Annex I of this directive. The product is in radio-interference protection class A in accordance with EN 55011.
The country of manufacture can be found on the equipment labeling.
The product complies with the requirements of standard EN 60601-1-2
“Electromagnetic Compatibility - Medical Electrical Equipment”.
The safety and effectiveness of this device has been verified against previously distributed devices. Although all standards applicable to presently marketed devices may not be appropriate for prior devices (i.e. electromagnetic compatibility standards), this device will not impair the safe and effective use of those previously distributed devices. See user’s information.
EMC Immunity Performance
WARNING
RF sources — Users should be aware of known RF sources, such as radio or TV stations and hand-held or mobile two-way radios, and consider them when installing a medical device or system.
Be aware that adding accessories or components, or modifying the medical device or system may degrade the
EMI performance. Consult with qualified personnel regarding changes to the system configuration.
Refer to the service manual for detailed exceptions and compliance information.
2021403-026B T-2100 Treadmill CE-1
CE Marking Information
CE-2 T-2100 Treadmill 2021403-026B
2021403-026B
Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1
T-2100 Treadmill Overview . . . . . . . . . . . . . . . . . . . . . . . . .2-1
T-2100 Treadmill i
3 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1
ii T-2100 Treadmill 2021403-026B
1
Introduction
2021403-026B T-2100 Treadmill 1-1
Introduction
Manual Information
Revision History
Each page of the document has the document part number and revision letter at the bottom of the page. The revision letter identifies the document’s update level.
The revision history of this document is summarized in the table below.
Revision
A
B
Date
7 February 2005
15 August 2007
Comment
Initial release of manual.
Revised equipment symbols and warnings.
Manual Purpose
This manual contains the instructions necessary to operate the equipment safely in accordance with its function and intended use. These instructions include but are not limited to:
an explanation of the function of controls and indicators, the sequence of operation, connection and disconnection of detachable parts and accessories, and
instructions for operator cleaning, preventive inspection and maintenance.
Where necessary the manual identifies additional sources of relevant information and/or technical assistance.
Intended Audience
This manual is geared for clinical professionals. Clinical professionals are expected to have working knowledge of medical procedures, practices, and terminology as required for completing these examinations.
1-2 T-2100 Treadmill 2021403-026B
Introduction
Conventions
Safety Messages
Below are the conventions used in this manual.
DANGER safety messages indicate an imminently hazardous situation which, if not avoided, WILL result in death or serious injury.
WARNING safety messages indicate a potentially hazardous situation which, if not avoided, COULD result in death or serious injury.
CAUTION safety messages indicate a potentially hazardous situation which, if not avoided may result in minor or moderate injury.
NOTE messages provide additional user information.
Definitions
Items shown in Bold text are keys on the keyboard, text to be entered, or hardware items such as buttons or switches on the equipment.
Items shown in Italicized text are software terms which identify menu items, buttons, or options in various windows.
To perform an operation which appears with a plus (+)sign between the names of two keys, you press and hold the first key while pressing the second key once. This is called a keystroke combination.
For example, “Press Ctrl+Esc” means to press and hold down the
Ctrl key while pressing the Esc key.
When instructions are given for typing a precise text string with one or more spaces, the point where the spacebar must be pressed is indicated as: <Space>. The purpose of the < > brackets is to ensure you press the spacebar when required.
Enter means to press the Enter or Return key on the keyboard. Do not type Enter.
2021403-026B T-2100 Treadmill 1-3
Introduction
Safety Information
Responsibility of the Manufacturer
GE Medical Systems Information Technologies is responsible for the effects of safety, reliability, and performance only if:
Assembly operations, extensions, readjustments, modifications, or repairs are carried out by persons authorized by GE Medical Systems
Information Technologies.
The electrical installation of the relevant room complies with the requirements of the appropriate regulations.
The equipment is used in accordance with the instructions for use.
General
This device is intended for use under the direct supervision of a licensed health care practitioner.
To ensure patient safety, use only parts and accessories manufactured or recommended by GE Medical Systems Information Technologies.
Contact GE Medical Systems Information Technologies for information before connecting any devices to this equipment that are not recommended in this manual.
Parts and accessories used must meet the requirements of the applicable
IEC 601 series safety standards, and/or the system configuration must meet the requirements of the IEC 60601-1-1 medical electrical systems standard.
The use of ACCESSORY equipment not complying with the equivalent safety requirements of this equipment may lead to a reduced level of safety of the resulting system. Consideration relating to the choice shall include: use of the accessory in the PATIENT VICINITY; and evidence that the safety certification of the ACCESSORY has been performed in accordance to the appropriate IEC 60601-1 and/or IEC
60601-1-1 harmonized national standard.
1-4 T-2100 Treadmill 2021403-026B
Introduction
Equipment Symbols
The following symbols may appear on the equipment.
Caution, consult accompanying documents.
Dangerous voltage.
Type B applied part complying with IEC 60601-1.
Alternating current (AC)
Equipotential (This is the ground lug.)
Protective earth (ground)
This symbol indicates that the waste of electrical and electronic equipment must not be disposed as unsorted municipal waste and must be collected separately.
Please contact an authorized representative of the manufacturer for information concerning the decommissioning of your equipment.
Manufacturer’s identification
Date of manufacture.
The number found under this symbol is the date of manufacture in the YYYY-MM format.
YYYY-MM
SN
Serial number
Catalogue number
Authorized representative in the European community
2021403-026B T-2100 Treadmill 1-5
Introduction
Medical Equipment
With Respect to Electric Shock, Fire, and Mechanical Hazard Only, In Accordance with UL
60601-1 and CAN/CSA C22.2 No.601.1
Input/Output
Input
Fuse
Serial Interface
Emergency stop
General symbol for recovery/recyclable
T 0.5AL, 250V Time Lag, 0.5 Amp, Low breaking capacity, 250Vac rated fuse
Warnings and Dangers
WARNING
CONNECTION TO MAINS — This is class 1, type B electrical safety equipment.
The mains plug must be connected to an appropriate power supply.
WARNING
DEFIBRILLATOR PRECAUTIONS — Do not come into contact with patients or unit during defibrillation.
Otherwise, serious injury or death could result.
WARNING
EMERGENCY STOP — The emergency stop switch is a safety device for use only in emergency situations to stop the treadmill. The walking belt will stop quickly. Once stopped and while the switch is depressed the treadmill walking belt will not lock to allow for removal of foreign objects.
1-6 T-2100 Treadmill 2021403-026B
Introduction
WARNING
EQUIPMENT MALFUNCTION — Replace only with the same type and rating of fuse.
WARNING
EXPLOSION HAZARD — Flammable anesthetic vapors or liquids can cause explosions.
Do NOT use in the presence of flammable anesthetic vapors or liquids.
WARNING
MOVING PARTS — To avoid injury, follow physicians’ or qualified health care providers’ instructions carefully during use of the equipment.
WARNING
MOVING PARTS — To avoid injury, keep hands, hair, jewelry, loose clothing and patient cables away from moving parts.
WARNING
MOVING PARTS — To avoid injury to patient, operate the treadmill with 6 feet of clearance at the rear (end opposite the motor).
WARNING
MOVING PARTS — While the emergency stop switch is depressed or when power is not applied to the treadmill the walking belt is not locked. The walking belt in this condition is allowed to move which could cause a person to lose balance and fall if they are standing on the belt. Note, the risk of belt movement is increased with higher treadmill grades or inclines.
2021403-026B T-2100 Treadmill 1-7
Introduction
1-8
WARNING
SHOCK HAZARD — Improper use of this device presents a shock hazard. Strictly observe the following warnings. Failure to do so may endanger the lives of the patient, the user, and bystanders.
To reduce the risk of electric shock do NOT remove cover
(or back). Refer servicing to qualified personnel.
When disconnecting the device from the power line, remove the plug from the wall outlet first, before disconnecting the cable from the device. Otherwise there is a risk of coming in contact with line voltage by inadvertently introducing metal parts in the sockets of the power cord.
Devices may be connected to other devices or to parts of systems only after making certain that there is no danger to the patient, the operators, or the environment as a result. Standards IEC 60601-1-1/EN60601-1-1 must be complied with in all cases.
WARNING
SITE REQUIREMENTS — Do not route cables in a way that they may present a stumbling hazard.
Do not route cables underneath the equipment.
For safety reasons, all connectors for patient cables and leadwires are designed to prevent inadvertent disconnection, should someone pull on them.
For devices installed above the patient, adequate precautions must be taken to prevent them from dropping on the patient.
WARNING
TREADMILL CHANGES — Rapid changes in treadmill speed and/or grade during a stress test may result in injury.
DO NOT rapidly change treadmill speed and/or grade during a stress test.
WARNING
TREADMILL CHANGES — DO NOT place feet under the treadmill during operation or while decreasing the treadmill grade to avoid injury.
T-2100 Treadmill 2021403-026B
Introduction
Cautions
CAUTION
INJURY — Do not use the treadmill without proper footwear as injury to feet may result.
Always wear proper footwear when using the treadmill.
CAUTION
POWER REQUIREMENTS — Before connecting the device to the power line, check that the voltage and frequency ratings of the power line are the same as those indicated on the unit's label. If this is not the case, do not connect the system to the power line until you adjust the unit to match the power source.
This equipment is suitable for connection to public mains as defined in CISPR 11.
CAUTION
RESTRICTED SALE — U.S. federal law restricts this device to sale by or on the order of a physician.
CAUTION
SUPERVISED USE — This equipment is intended for use under the direct supervision of a licensed health care practitioner.
Make sure all users are under the direct supervision of a licensed health care practitioner.
Service Information
Service Requirements
Refer equipment servicing to GE Medical Systems Information
Technologies authorized service personnel only. Any unauthorized attempt to repair equipment under warranty voids that warranty.
It is the user’s responsibility to report the need for service to GE Medical
Systems Information Technologies or to one of their authorized agents.
Failure on the part of the responsible individual, hospital, or institution using this equipment to implement a satisfactory maintenance schedule may cause undue equipment failure and possible health hazards.
2021403-026B T-2100 Treadmill 1-9
Introduction
Equipment Identification
The Equipment Identification tag contains the Serial Number, and is located on the back of the treadmill.
Serial Number
Regular maintenance, irrespective of usage, is essential to ensure that the T-2100 Treadmill will always be functional when required.
Technical specifications describing the equipment can be found in the T-
2100 Treadmill Service Manual shipped with your system.
Every GE Medical Systems Information Technologies device has a unique serial number for identification. An explanation of the Serial
Number code is shown below.
A B
C D E
F
A
B
E
F
C
D
Product Code
Year Manufactured (00-99)
00 = 2000
01 = 2001
02 = 2002
(and so on)
Fiscal Week Manufactured
Production Sequence Number
Manufacturing Site
Miscellaneous Characteristic
001
1-10 T-2100 Treadmill 2021403-026B
2
T-2100 Treadmill
Overview
2021403-026B T-2100 Treadmill 2-1
T-2100 Treadmill Overview
Intended Use
The T-2100 Treadmill is intended for use with any of the several GE
Medical Systems Information Technologies exercise testing systems or the MTC-1 (manual treadmill controller), for administering a controlled exercise load during a diagnostic stress test. Standard features include the emergency stop switch, a full handrail set, and a long, 60-inch walking surface.
The emergency stop switch is intended for emergency situations where immediately stopping the treadmill is required to deliver appropriate emergency care to the patient or health care provider, as implied by the
American Heart Association “Guidelines for Clinical Exercise Testing
Laboratories” (1995). It is not intended for routinely stopping the treadmill.
Preparation for Use
Safe Handling Guidelines
The T-2100 Treadmill ships preset with an approximate 2% grade. This slight elevation provides for free wheel movement and prevents the shroud from scraping the floor.
Before moving the treadmill after it has been in operation, use the controlling equipment to set the grade to approximately 7%. Then remove power and disconnect all cables to the treadmill before moving the unit.
Follow the steps below to move the treadmill. We recommend that two people work together since the treadmill may be too heavy for some individuals to lift and lower safely.
NOTE
We recommend the treadmill not be placed on carpet or carpet tile floors as a final location, as continual movement of the wheels may eventually damage the carpet and possibly the treadmill.
2-2 T-2100 Treadmill 2021403-026B
T-2100 Treadmill Overview
WARNING
INJURY OR DAMAGE — The treadmill is too heavy to lift, lower or move safely by one person. Serious bodily injury or damage to the treadmill may result.
A minimum of two people are required when lifting, lowering or moving the treadmill.
1. Lift the end of the bed assembly to about knee height, keeping knees bent and backs straight as you lift.
2. Rotate the treadmill in the direction you want to go (the treadmill will pivot on its wheels) and push forward.
3. When you have maneuvered the treadmill into its new location, gently lower the end of the bed assembly to the floor.
Operating Instructions
Electrical Safety Tests
The electrical safety of this installation is the responsibility of the customer, not GE Medical Systems Information Technologies. In hospitals, contact your in-house biomedical technician, electrician, or technically qualified personnel. Outside of hospitals, contact your hospital affiliation for these services. Otherwise, contact GE Medical
003
2021403-026B T-2100 Treadmill 2-3
T-2100 Treadmill Overview
Systems Information Technologies and open a customer-billable service call.
Before using the treadmill, have qualified personnel perform the tests listed below.
AC line voltage test to verify the power outlet is properly wired.
Ground continuity test to verify all exposed metal is properly grounded.
Leakage tests to verify the equipment passes all applicable leakage tests.
Your in-house biomedical technician, electrician, or technically qualified personnel can find instructions for performing these tests in the T-2100
Treadmill Service Manual shipped with your system.
Calibrating Treadmill
It is recommended that the treadmill be calibrated each time it is moved.
Refer to the steps below to activate the T-2100 Treadmill self-calibration feature:
1. Connect the AC power cable on the treadmill to the wall outlet.
WARNING
POWER CABLES — Route the AC Power cable away from moving parts.
An AC power cable caught in moving parts could cause injury to the user and equipment.
2. Turn the power switch on the treadmill to On.
3. Remove controlling device cable or turn off the controlling device.
WARNING
During calibration, the treadmill will move and reach maximum elevation. Injury may result.
Make sure you monitor the site at all times.
Make sure there are no customers or patients near the treadmill during calibration.
2-4 T-2100 Treadmill 2021403-026B
T-2100 Treadmill Overview
4. A push button is located at the rear panel. Hold down the push button and power cycle the unit. Hold the push button in for at least
4 seconds after power up for calibration to occur.
The software calibrates the speed and grade from the minimum points to the maximum points.
Operating Controls
The treadmill has two operating controls, the power switch and the emergency stop switch. The power switch is located on the rear panel, and the emergency stop switch is on the front handrail.
Power Switch
The power switch controls the AC power to the treadmill. The On position (I) applies power. The Off position (0) removes power.
Emergency Stop Switch
The emergency stop switch is a safety device for use in emergency situations to stop the treadmill. Press the STOP push-button and the treadmill promptly stops. Please note the belt will not lock after the treadmill is stopped, allowing for removal of foreign objects.
To release the emergency stop switch, turn the push-button 1/4-turn in either direction.
Emergency Stop Switch Check
NOTE
Verify proper operation of the stop switch assembly every month.
With the belt moving at a relatively high speed, press the emergency stop switch. The treadmill belt will stop promptly but the belt will not lock, allowing for removal of foreign objects. To release the switch, turn the button 1/4-inch turn in either direction.
Use the controlling equipment to terminate the exercise session and turn off the treadmill.
2021403-026B T-2100 Treadmill 2-5
T-2100 Treadmill Overview
Controlling the Treadmill
Turn the power switch On (I).
Use the controlling equipment to start the treadmill, adjust the treadmill speed and grade, proceed through the exercise phases, terminate the exercise session, and turn off the treadmill. Refer to the appropriate controlling equipment Operator Manual for instructions.
2-6 T-2100 Treadmill 2021403-026B
3
Maintenance
2021403-026B T-2100 Treadmill 3-1
Maintenance
Introduction
Recommended Maintenance
Refer to the T-2100 Treadmill Service Manual shipped with your system for detailed maintenance information.
NOTE
Unless you have an Equipment Maintenance Contract, GE Medical
Systems Information Technologies does not in any manner assume the responsibility for performing the recommended maintenance procedures. The sole responsibility rests with the individual or institution using the equipment. GE Medical Systems Information
Technologies service personnel may, at their discretion, follow the procedures provided in this manual as a guide during visits to the equipment site.
Inspection and Cleaning
Visual Inspection
Perform a visual inspection daily. Turn off the unit and remove power before making an inspection or cleaning the unit. If you notice any items that need repair, contact an authorized service person to make the repairs.
Inspect the following for excessive wear or damage:
Walking belt
Drive belt
Handrail and hardware
All cords and cables for fraying or other damage.
Verify that all cords and connectors are securely seated.
Exterior Cleaning
Turn the treadmill system off. Clean the exterior surfaces with a clean, soft cloth and a mild dishwashing detergent diluted in water. Wring out the excess water from the cloth and take care not to drip solutions on the keyboard or writer assembly. (Use anti-septic cleaner on the handrails and walking belt.) Avoid contact with open vents, plugs or connectors.
Dry the surfaces with a clean cloth or paper towel.
Disposal of the Product
3-2
The product described in this operator manual must not be disposed of as unsorted municipal waste and must be collected separately. Please contact an authorized representative of the manufacturer for information concerning the decommissioning of your equipment.
T-2100 Treadmill 2021403-026B
Index
C
Calibrating the Treadmill 2-4
CE Marking Information CE-1
Controlling the Treadmill 2-6
Conventions 1-3
D
Definitions 1-3
E
Electrical Safety Tests 2-3
Equipment Identification 1-9
I
Equipment Symbols 1-5
Intended Use 2-2
M
Manual Purpose 1-2
Moving the Treadmill - How to 2-2
Index
O
Operating Controls 2-5
Operating Controls - Emergency Stop Switch 2-5
Operating Controls - Emergency Stop Switch
Check 2-5
Operating Controls - Power Switch 2-5
R
Responsibility of the Manufacturer 1-4
Revision History 1-2
S
Safe Handling Guidelines 2-2
Safety Information - Cautions 1-9
Safety Information - General 1-4
Safety Information - Warnings and Dangers 1-6
Safety Messages - Description 1-3
Serial Number 1-10
Service Requirements 1-9
2021403-026B T-2100 Treadmill Index-1
Index
Index-2 T-2100 Treadmill 2021403-026B
World Headquarters
GE Medical Systems
Information Technologies, Inc.
8200 West Tower Avenue
Milwaukee, WI 53223 USA
Tel: + 1 414 355 5000
1 800 558 5120 (US only)
Fax: + 1 414 355 3790
European Representative
GE Medical Systems
Information Technologies GmbH
Munzinger Straße 3-5
D-79111 Freiburg
Germany
Tel: + 49 761 45 43 - 0
Fax: + 49 761 45 43 - 233
Asia Headquarters
GE Medical Systems
Information Technologies Asia; GE (China) Co., Ltd.
24th Floor, Shanghai MAXDO Center,
8 Xing Yi Road, Hong Qiao Development Zone
Shanghai 200336, P.R. China
Tel: + 86 21 5257 4650
Fax: + 86 21 5208 2008
advertisement
Related manuals
advertisement
Table of contents
- 5 Contents
- 7 1 Introduction
- 8 Manual Information
- 8 Revision History
- 8 Manual Purpose
- 8 Intended Audience
- 9 Conventions
- 9 Safety Messages
- 9 Definitions
- 10 Safety Information
- 10 Responsibility of the Manufacturer
- 10 General
- 11 Equipment Symbols
- 12 Warnings and Dangers
- 15 Cautions
- 15 Service Information
- 15 Service Requirements
- 16 Equipment Identification
- 16 Serial Number
- 17 2 T-2100 Treadmill Overview
- 18 Intended Use
- 18 Preparation for Use
- 18 Safe Handling Guidelines
- 19 Operating Instructions
- 19 Electrical Safety Tests
- 20 Calibrating Treadmill
- 21 Operating Controls
- 21 Power Switch
- 21 Emergency Stop Switch
- 21 Emergency Stop Switch Check
- 22 Controlling the Treadmill
- 23 3 Maintenance
- 24 Introduction
- 24 Recommended Maintenance
- 24 Inspection and Cleaning
- 24 Visual Inspection
- 24 Exterior Cleaning
- 24 Disposal of the Product
- 25 Index