MIRA SPORT ELECTRIC SHOWERS Installation & User Guide


Add to my manuals
32 Pages

advertisement

MIRA SPORT ELECTRIC SHOWERS Installation & User Guide | Manualzz

7.5, 9.0 & 9.8 kW

MIRA SPORT

ELECTRIC SHOWERS

Installation & User Guide

These instructions are to be left with the user

1

CONTENTS

Introduction .............................................................................................3

Guarantee ............................................................................................

3

Recommended Usage .........................................................................

3

Patents and Design Registration ..........................................................

3

Important Safety Information .................................................................4

Pack Contents Checklist ........................................................................6

Specifications ..........................................................................................7

Installer Instructions ...............................................................................8

Plumbing Checklist ...............................................................................

8

Electrical Checklist .............................................................................

10

Installation .............................................................................................12

Commissioning .....................................................................................14

User Instructions ...................................................................................16

Fault Diagnosis ......................................................................................19

Maintenance ...........................................................................................23

Dimensions ............................................................................................24

Wiring Diagram ......................................................................................25

Spare Parts ............................................................................................26

Accessories ...........................................................................................28

Notes ......................................................................................................29

Customer Service ..................................................................................32

If you experience any difficulty with the installation or operation of your new Electric

Shower, please refer to

‘Fault Diagnosis’

, before contacting Kohler Mira Ltd. Our telephone and fax numbers can be found on the back cover of this guide.

2

INTRODUCTION

Thank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please take time to read this guide thoroughly. Having done so, keep it handy for future reference.

The Mira Sport is an electric shower with separate controls for power selection and temperature/flow adjustment. A unique flow regulator stabilises temperature changes caused by water pressure fluctuations. These can result from taps being turned on or off or toilets being flushed. Individual lights indicate "POWER" and "LOW FLOW".

Mira Sport models covered by this guide:

Mira Sport 7.5

- A 7.5 kW 240 V AC (6.85 kW 230 V AC) heater. Available in white/ chrome finish.

Mira Sport 9.0

- A 9.0 kW 240 V AC (8.2 kW 230 V AC) heater. Available in white, white/chrome, and chrome finishes.

Mira Sport 9.8

- A 9.8 kW 240 V AC (9.0 kW 230 V AC) heater. Available in white, white/chrome, and chrome finishes.

Guarantee

For

domestic installations

, Mira Showers guarantee the Mira Sport against any defect in materials or workmanship for a period of

2 years

from the date of purchase

(shower fittings for one year).

For

non-domestic installations

, Mira Showers guarantee the Mira Sport against any defect in materials or workmanship for a period of

1 years

from the date of purchase.

For Terms and Conditions refer to the back cover of this guide.

Recommended Usage

Domestic

Recommended Usage

Light Commercial

Heavy Commercial

Healthcare

ü

ü

û

û

Patents and Design Registration

Design Registration: 000373543-002-004

Patents: GB: 2 341 667

Ireland: 82835

Patent Applications: UK: 2 427 460, 2 432 201

Ireland: 2006/0462, 2006/0818

3

IMPORTANT SAFETY INFORMATION

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY:

1.

I nstallation of this shower must be carried out in accordance with these instructions, and must be conducted by competent personnel.

2.

I solate the electrical and water supplies before commencing installation. The electricity must be switched off at the consumer unit and the appropriate circuit fuse removed, if applicable.

3.

T he electrical installation must comply with BS 7671 (commonly referred to as the IEE Wiring Regulations) and all relevant building regulations, or any particular regulation or practice specified by the local electricity supply company.

4.

T he plumbing installation must comply with all national or local water regulations and all relevant building regulations, or any particular regulation or practice specified by the local water supply company.

5.

T his shower is intended to be permanently connected to the fixed electrical wiring of the mains system. A separate supply must be provided from the consumer unit to the shower.

6.

T his shower must be provided with means for disconnection that is incorporated into the fixed wiring in accordance with the relevant local wiring regulations. The isolating switch must be local to the appliance and may be a ceiling mounted pullcord type or a wall mounted switch fitted in an appropriate zone area.

7.

I n accordance with BS7671 a 30mA Residual Current Device (RCD)

must

be fitted. This may be part of the consumer unit or a separate unit.

8.

T his shower must be earthed. Ensure any supplementary bonding complies with the relevant regulations.

9.

E nsure all electrical connections are tight, to prevent overheating.

10.

T his shower must not be fitted where it may be exposed to freezing conditions.

Ensure that any pipe-work that could become frozen is properly insulated.

11.

T his shower is not suitable for areas with high humidity or temperature (i.e. steam rooms and saunas).

12.

M ains connections are exposed when the cover is removed, only a competent person should remove the front cover. We recommend any maintenance work is carried out by a Mira Service Engineer or suitably qualified tradesperson.

There are no user serviceable parts inside the shower.

13.

DO NOT

switch on if water leaks from the main enclosure. Isolate the electrical supply to the shower immediately.

14.

DO NOT

switch on if there is a possibility that the water in the shower is frozen.

15.

T he outlet must not be connected to any tap, outlet control or showerhead other than those specified for use with this shower. Only Kohler Mira recommended accessories should be used.

4

16

. Electric showers can deliver scalding temperatures if not operated, installed or maintained in accordance with the instructions, warnings and cautions contained in this guide and on or inside the shower.

17.

R apid or excessive operation of the shower controls may result in high or unstable outlet water temperatures. Operate controls gradually and allow 10-15 seconds to stabilise checking the temperature before entering the shower.

18.

T his shower is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the shower by a person responsible for their safety.

19.

C hildren should be supervised to ensure that they do not play with the shower.

20.

A lways switch off the shower at the electrical isolating switch when not in use.

21.

T he showerhead must be de-scaled regularly.

22.

DO NOT

allow the handset to spray water directly on to the shower. Eg. When cleaning shower control.

23.

I f the shower is not to be used for a long period, the water supply to the shower must be isolated. If the shower or pipe-work is at risk of freezing during this period, they should also be drained of water.

If any of the following conditions occur, isolate the electricity and water supplies and refer to “To contact us”, on the back page of this guide.

• If the cover is not correctly fitted and water has entered the shower case

• If the case is damaged

• If the shower begins to make an odd noise, smell or smoke

• If the shower shows signs of a distinct change in performance indicating a need for maintenance

• If the shower is frozen

5

PACK CONTENTS CHECKLIST

Tick the appropriate boxes to familiarize yourself with the part names and to confirm that the parts are included.

q

1 x Mira Sport 7.5, 9.0 or 9.8

q

1 x Olive q

1 x Compression Nut q

3 x Fixing Screws q

3 x Wall Plugs q

2 x Case Inserts

Documentation

q 1 x Installation Template q 1 x Installer Checklist q 1 x Guarantee Card

6

SPECIFICATIONS

1. Plumbing

1.1

Minimum maintained inlet pressure 70 kPa (0.7 bar) for satisfactory operation.

1.2

Maximum static inlet pressure 1000 kPa (10 bar).

1.3

Minimum static pressure 20 kPa (0.2 bar) to keep the flow valve closed.

2. Electrical

2.1

The Mira Sport 7.5 kW @ 240 V AC (6.85 kW @ 230 V AC) and 9.0 kW @

240 V AC (8.2 kW @ 230 V AC) require a 40 Amp circuit protection device.

The Mira Sport 9.8 kW @ 240 V AC (9.0 kW @230 V AC) requires a 45 Amp circuit protection device.

2.2

The terminal block will accept cable up to 16 mm² (7.5, 9.0 and 9.8 kW).

2.3

The Mira Sport complies with all relevant directives for CE marking.

2.4

The Mira Sport is suitable for installation in zone 1 and is rated IPX4.

3. Standards and Approvals

3.1

The Mira Sport complies with all relevant directives for CE marking.

7

INSTALLER INSTRUCTIONS

Read the section

“Important Safety Information”

first.

Plumbing Checklist

1.

Minimum maintained inlet pressure = 70 kPa (0.7 bar).

Maximum static inlet pressure = 1000 kPa (10 bar).

2.

Water treatment device (if required).

3.

Free flowing isolating valve.

4.

Positioned over water catchment area.

5.

Fitted to finished wall surface.

6.

No sharp hose kinks.

7.

Fittings should be positioned with a greater than 25 mm gap. If this is not achievable then an outlet double checkvalve

must be

fitted.

8.

Supply pipework flushed clear.

9.

Watertight inlet connection and fittings.

10.

Case inserts fitted and Cover secured correctly.

Minimum

200 mm from ceiling

Convenient height for all the family

Fixed to finished wall surface

Isolating Valve

Avoid sharp kinks

Bath

Soap Dish/Hose Retaining Ring

25 mm Min

Shower Tray

8

Plumbing (checklist in detail)

1.

The appliance is designed to operate with a minimum maintained inlet pressure of 70 kPa (0.7 bar) up to a maximum static inlet pressure of 1000 kPa

(10 bar).

2.

When installed in very hard water areas (above 200 ppm temporary hardness) your installer may advise the installation of a water treatment device, to reduce the effects of limescale formation. Your local water company will be able to advise the hardness of water in your area.

3.

It is recommended that a non-restrictive (free flowing) isolating valve is fitted in the cold water supply pipe to allow the complete maintenance of the Mira

Sport. Do not use a valve with a loose washer plate (jumper) as this can lead to a build up of static pressures.

4.

The appliance is suitable for installation within the shower area. It is fitted with a pressure relief device and must be positioned over a water catchment area with the controls at a convenient height for all users.

5.

The appliance must be fitted onto a finished flat and even wall surface (this wall surface should be tiled or waterproofed). Do not fit the appliance to the wall and tile up to the case. For safety requirements, an air gap must be left behind the appliance.

6.

Avoid layouts where the shower hose will be sharply kinked. This may reduce the life of the hose.

7.

A Soap Dish/Hose Retaining Ring is supplied to prevent the handset from dropping below the spill-over level of the bath or shower, which could lead to contamination from back-siphoning. The supplied Hose Retaining Ring should meet the great majority of user requirements for shower installations with flexible outlet fittings. However, there will be occasions when it will not provide a suitable solution. In these instances an outlet double checkvalve, e.g. a Mira

DCV-H, must be fitted. This will increase the required supply pressure typically by 10 kPa (0.1 bar) (see section "Accessories").

8.

Supply pipework must be flushed to clear debris before connecting to the appliance.

9.

To avoid damage to the case when soldered fittings are used, pre-solder the pipework and fittings before connecting them to the inlet connector assembly.

Refrain from applying excessive force when making any connections. Always provide mechanical support when making the plumbing connections.

10.

The appliance is fitted with a brass inlet compression assembly for connecting to a 15 mm supply pipe from the top, bottom or back. Double checkvalves, fitted in the inlet supply to the appliance, cause a pressure build-up, which could exceed the maximum static inlet pressure and damage the appliance.

9

Read the section

“Important Safety Information”

first.

Electrical Checklist

1.

A 30 mA residual current device (RCD) has been fitted.

2.

Electrical supply fuse and consumer unit are adequate for the product.

3.

Shower unit is earthed.

4.

The minimum required supply cable size must conform to BS 7671.

5.

Double pole isolating switch.

6.

Do not twist live or neutral cable cores.

7.

Electrical connections are tightly secured.

Do not

strain terminal block.

8.

Plumbing supply completed before electrical supply is turned on.

Consumer Unit

Double-pole Isolating

Switch

10

Electrical (checklist in detail)

1.

In a domestic installation, the rating of the electricity supplier's fuse and the consumer unit must be adequate for the additional demand. All Mira Sport electric showers are high power units, therefore it is essential to contact your electricity supplier to ensure that the supply is adequate for the product. Voltage drop due to local heavy demand will reduce the shower's performance.

2.

The Mira Sport

must be earthed

by connecting the supply-cable earth conductor to the earth terminal.

Supplementary bonding:

Within the bathroom or shower room, all accessible conductive parts of electrical equipment and extraneous conductive parts (metal parts) that are likely to introduce earth potential, must be electrically bonded to earth using a minimum cable size of 4.0 mm

2

if the cable is not mechanically protected, (2.5 mm

2

if mechanically protected).

3.

Supply cable - see opposite.

4.

As a guide only

, and in accordance with BS 7671 we recommend close circuit protection: i.e. 7.5 kW & 9.0 kW = 40 Amp, 9.8 kW = 45 Amp

5.

A 30 mA Residual Current Device (RCD)

MUST

be included in the electrical circuit (BS7671). This may be part of the consumer unit or a separate unit.

A separate, permanently connected supply is taken from the consumer unit to the appliance through a double-pole switch, which has at least 3 mm contact separation. The switch can be a ceiling mounted pullcord type within the shower room or a wall mounted switch in an adjacent room.

6. DO NOT

twist the individual cable cores of either the live or neutral conductors, as this will prevent them from entering the terminal block.

7. DO NOT

exert strain on the terminal block. Ensure that the electrical connections are tightly screwed down.

8. DO NOT

turn on the electrical supply until the plumbing has been completed.

11

INSTALLATION

Read the section

“Important Safety Information”

first

1.

2.

200 mm

3.

Electrical supply is turned off at the mains.

200 mm minimum gap from ceiling.

Remove three screws.

4.

5.

6.

R e m o v e c o v e r a n d determine supply pipe position.

For back inlet use soldered elbow.

Do not trap green wire.

Caution!

Do not drill into buried cables or pipes.

7.

INSTALLATION TEMPLATE

8.

9.

Mira Sport

Attention Installer

Drill and plug* the three holes using template.

Fix appliance to wall.

Flush a minimum of 10 litres through pipework.

* Alternative fixings for some wall structures are not supplied.

12

10.

11.

12.

Connect supply pipe. Do not overtighten!

L = BROWN

E = GREEN

N = BLUE

Important!

Make sure that the inlet earth wire is routed as shown. Failure to do so may cause product malfunction.

13.

Feed cable into Case. Fit Earth sleeve (not supplied) and strip insulation.

Do not twist cable cores.

14.

Firmly connect the conductors.

Do not exert strain on the terminal block.

15.

Make sure wires are clear of all mounting holes.

Refit the Service Tunnel and Cover.

Make sure they fit correctly.

Do not overtighten screws.

13

Do not use alternative screws to secure the Cover. This can cause internal damage to the appliance.

Do not seal around the back of appliance.

COMMISSIONING

Before carrying out the commissioning procedure install the Shower Fittings, refer to the Shower Fittings Installation and User Guide.

If you are unsure how an electric shower works, please read through the

User

Instructions

section before continuing.

1.

2.

3.

Electrical supply is turned off at the mains.

Turn control to full cold.

4.

5.

Turn water supply fully on.

6.

Check for water leaks.

7.

Set control to LOW.

8.

Switch on electrical supply.

9.

Push START button.

10.

Turn control to full cold.

COLD

0 - 5 secs

Water will be at full force and at a cool temperature.

11.

Turn control slowly.

Temperature remains cool and flow is reduced.

12.

+

Set control to MEDIUM.

14

_

5 - 10 secs

The temperature will rise slightly.

13.

15.

Set control to HIGH.

14.

+

_

5 - 10 secs

The temperature will rise further.

16.

17.

Adjust temperature as required.

Flow rate will adjust automatically.

18.

Press STOP and isolate power.

0 - 5 secs

The shower will purge water from its tank for a few seconds.

Residual water may drain over a few minutes.

Note!

A slight hissing sound may be heard from the Mira Sport during operation.

High mains water pressure and high shower temperatures will affect the tone. This is quite normal in use.

15

USER INSTRUCTIONS

How Your Electric Shower Works

Hot water is produced by passing cold water through a heating tank.

+

COLD

_

The shower has three heater settings.

+

_

+

_

The warmer the shower, the lower the flow rate and vice versa.

16

The Effect of Seasonal Changes

+

_

* * *

For a cold shower select LOW

For a summer warm shower select MEDIUM

For a winter warm shower select HIGH

Adjust the temperature as required

The flow rate will adjust automatically

The Effect of Other Water Devices

Example of how shower temperature stabilizes due to pressure changes.

Selected

Showering

Temperature

+

_

Showering temperature will stabilize to within 6°C band if other outlets are opened whilst showering, providing the minimum pressure does not fall below 70 kPa (0.7 bar).

Water inlet pressure fluctuations due to other draw offs (e.g. flushing toilet) will cause the showering temperature to increase.

17

Using Your Shower

Read the section

“Important Safety Information”

first.

1.

2.

3.

Switch on electrical supply.

4.

Press START button.

+

_

Set to desired position.

Check water temperature before entering shower.

+

5.

6.

_

Allow 10-15 seconds for any temperature adjustments to reach the handset.

7.

Press STOP button. Shower will continue to run for a few seconds before stopping.

18

A small amount of water may continue to drain over a few minutes.

FAULT DIAGNOSIS

The trouble shooting information tabled below gives details on probable causes and remedies should difficulties be encountered whilst the shower is in operation.

Warning!

There are no user serviceable components beneath the cover of the appliance.

Only a competent trades person should remove the front cover!

A p p l i a n c e f a i l s t o operate.

OFF

Low

Flow

Light

OFF

Heater

Low/

Med/

High

Any

Probable Cause

Electrical supply isolated at double pole switch.

Possible Remedy

Switch on electrical s u p p l y v i a t h e pullcord or wall mounted switch.

S h o w e r cycles from hot to cold .

OFF

ON

OFF

ON

Any

Med/

High

F u s e b l o w n o r

MCB/RCD tripped, indicating possible electrical fault.

Handset blocked.

Renew the fuse or reset the MCB/

R C D . I f f a u l t persists, contact your installer.

Remove and clean.

ON

ON

ON

OFF

Med/

High

Med/

High

Water pressure below minimum r e q u i r e d f o r a p p l i a n c e operation.

Make sure incoming m a i n s w a t e r stopcock and/or appliance isolating valve is fully turned on.

Temperature dial or heater setting too high.

Turn the heater selector knob to medium or turn the temperature c o n t r o l u n t i l a cooler temperature is achieved.

19

Low

Flow

Light

Heater

Low/

Med/

High

Probable Cause Possible Remedy

U n a b l e t o s e l e c t a cool enough shower.

ON OFF High Due to the rise in mains water supply temperature, the

Heater setting may be too high.

Turn the heater selector knob to medium and adjust the temperature c o n t r o l u n t i l a suitable temperature is achieved.

All the following remedies must be performed by a competent tradesperson !

H a n d s e t dripping.

OFF OFF Any Insufficient water supply pressure for shut off.

Min static pressure to ensure shut off and prevent dripping is 20 kPa (0.2 bar).

N o t e !

I f o t h e r a p p l i a n c e s a r e operating, static p r e s s u r e m a y drop below 20 kPa

(0.2 bar). Contact local water company.

Renew Flow Valve.

Low or no flow.

OFF

ON

OFF

ON

Any Flow Valve faulty.

Replace.

Any W a t e r s u p p l y pipework or inlet filter restricted by a blockage or partial blockage.

Flush supply pipe.

Clean Inlet Filter.

Insufficient water supply pressure/ flow for operation.

Contact local water company. Supply pressure must be a minimum of 70 kPa

(0.7 bar).

N o t e !

I f o t h e r a p p l i a n c e s a r e operating, pressure may drop below

70 kPa (0.7 bar).

(cont....)

20

Low or no flow.

(cont....)

ON

ON

ON

ON

ON

Operation of

Temperature

C o n t r o l has little or n o e f f e c t o n w a t e r temperature .

ON

ON

ON

ON

ON

OFF

OFF

OFF

OFF

OFF

OFF

Low

Flow

Light

ON

Heater

Low/

Med/

High

Any

Probable Cause Possible Remedy

Other outlets (e.g. toilet, garden hose, washing machine, etc.) drawing water while the shower is being used.

Tu r n o f f o t h e r appliances whilst shower is in use.

OFF Any Handset blocked.

Remove and clean.

Any

Any

Any

Med/

High

Med/

High

Med/

High

Med/

High

Service tunnel or cover not fitted correctly causing

Start/Stop button not to operate.

Flow Valve faulty.

Check case inserts are cut and fitted correctly. Check services (electrical or plumbing) are not interfering with location of service tunnel or cover.

Replace.

H e a t e r T a n k excessively scaled.

Handset or Inlet

Filter blocked.

Replace. In hard water areas consider the use of a water softener.

Remove and clean.

Flow Valve faulty.

Replace.

Heater Tank failure.

Replace.

Microswitch failure.

Replace.

21

No change in temperature between Low/

Medium/High setting.

Water will not turn off.

ON

ON

A p p l i a n c e f a i l s t o p r o d u c e h o t w a t e r w h e n s e t on Medium/

High Heater

Setting.

ON

ON

ON

ON

ON

OFF

OFF

Low

Flow

Light

ON

OFF

OFF

Heater

Low/

Med/

High

Any

Probable Cause Possible Remedy

Insufficient mains water pressure.

Contact local water company.

Any

Any

Possible failure o f f l o w v a l v e , microswitch, or heater tank.

Flow valve, solenoid, or Start/Stop switch faulty.

U s e a s u i t a b l e continuity device to check the continuity of the microswitch or heater tank and replace parts as necessary.

R e p l a c e a s necessary.

ON

ON

Any

Med/

High

Supply pressure b e l o w 2 0 k P a

(0.2 bar).

Insufficient water supply.

Contact local water company. Check mains water static pressure.

Contact local water company.

Med/

High

Med/

High

Possible failure of the microswitch or thermal switch.

U s e a s u i t a b l e continuity device to check the continuity of the microswitch or heater tank and replace parts as necessary.

Heater tank failure.

Replace.

22

MAINTENANCE

Inlet Filter Cleaning/Renewing

Read the section

“Important Safety Information”

first.

1.

2.

3.

Electrical supply is turned off at the mains.

Turn water supply fully off.

Remove three screws,

C o v e r a n d S e r v i c e

Tunnel.

4.

5.

Hold a wrench across the flats of the metal connector. Unscrew the filter using another wrench as shown. Clean or renew the Filter as necessary. Refit in reverse order making sure the Filter is screwed fully home.

Do not overtighten. Make sure plumbing connections are sealed before restoring electricity supply.

Note!

The shower head must be descaled regularly.

23

204 mm

DIMENSIONS

80 mm

24

L

N

E

WIRING DIAGRAM

BROWN

BLACK

Power On

Neon

Solenoid

Valve

Thermal Cutout

Dual Disc

RED

BROWN

Pressure/Power

Selector Switch

Low Flow

Neon

BLUE

BLACK

START/STOP

BROWN RED

Load

GREEN

GREEN

BLUE

Tank Connection

Inlet Connector

BROWN

BLACK

RED

Internal Wiring Diagram

25

SPARE PARTS

405.58

406.27

416.38

416.41

416.48

416.51

872.01

872.28

Inlet Connector Assembly

Inlet Filter (with 'O' seal fitted)

Clamp Bracket (Inlet)

Thermal Switch

Latching Switch

Solenoid Coil

Microswitch N/O - 2 pin

Microswitch C/O - 3 pin

1563.500 Heater Tank 7.5 kW 240 V AC (6.85 kW 230 V AC)

1563.502 Heater Tank 9.0 kW 240 V AC (8.2 kW 230 V AC)

1563.504 Heater Tank 9.8 kW (9.0 kW 230 V AC)

1563.507 Flow Valve Assembly

1563.509 Switching Assembly

1563.511 Cover Assembly

1563.513 Screw Pack - components identified 'A'

1563.514 Low Flow Neon Assembly

1563.515 Power On Neon Assembly

1563.516 Outlet Connector

1563.517 Service Tunnel

1563.518 Component Pack - components identified 'B'

1563.519 Terminal Block Assembly 9.8 kW 240 V AC (9.0 kW 230 V AC) only

1563.520 Wire Pack (not shown)

1563.522 Cover Seal (not shown)

1695.017 Cover Assembly (Chrome)

1695.018 Service Tunnel (Chrome)

1695.019 Component Pack (Chrome) Not Shown

1695.026 Case Insert Chrome Top (Not Shown)

1695.027 Case Insert Chrome Bottom (Not Shown)

Note!

Case inserts 1695.026 and 1695.027 adapted for chrome variants with top or bottom service entry points are available on request.

26

B

B

B

B

B

B

B

405.58

B

1563.517

1695.018

B

1563.519

A

1563.509

872.28

406.27

1563.507

A

416.41

1563.502

1563.500

1563.504

1563.511

1695.017

1563.515

1563.514

872.01

416.38

A

1563.516

416.48

416.51

4 mm MINIMUM

Important!

Push-fit connectors must be assembled back to back onto terminals of micro-switches.

A minimum air gap of 4 mm must be maintained between the connectors after assembly.

27

ACCESSORIES

Genuine Mira accessories can be purchased direct from Customers Services (our contact details can be found on the back cover of this guide) or from approved stockists or merchants.

Everclear Showerhead

White - 2.1616.030

Chrome - 2.1616.031

Mira's new Everclear range has been specially designed for hard water areas and reduces the risk of lime scale build up.

Logic Showerhead Holder

White - 2.1605.149

White/Chrome - 2.1605.150

An alternative to the traditional slide bar. Often a useful addition when positioned for the smaller members of the family.

Shower Seat

White - 2.1536.128

White/Chrome - 2.1536.129

For use in or out of the showering area. Folds up when not in use .

Maximum User Weight - 127 kg

(20 stone)

Note!

Must be installed onto a solid wall.

Outlet Double Check Valve

(DCV-H)

Chrome - 1.0.110.55.1

An outlet double check valve, designed to prevent the back flow or back-siphonage of potentially contaminated water, through shower controls which are fitted with a flexible shower hose as part of the outlet shower fitting.

Mira Standard Grab Bars

300 mm - 2.1605.070

450 mm - 2.1605.071

600 mm - 2.1605.072

Premium grade, highly polished, stainless steel grab bars.

Note!

Must be installed onto a solid wall.

Premium Shower Seat

White/Chrome - 2.1731.001

Grey/Chrome - 2.1731.002

Stylish, slim-line and robust shower seat for use in or outside of the shower area.

Folds up when not in use. Maximum User Weight

- 150 kg (23.5 stone)

Note!

Must be installed onto a solid wall.

28

NOTES

29

NOTES

30

NOTES

31

CUSTOMER SERVICE

Guarantee

Your product has the benefit of our manufacturer’s guarantee which starts from the date of purchase.

To activate this guarantee, please return your completed registration card, visit our website or free phone 0800

0731248 within 30 days of purchase (UK only).

Within the guarantee period we will resolve defects in materials or workmanship, free of charge, by repairing or replacing parts or product as we may choose.

If you have not previously activated the guarantee, you will be required to do so prior to the provision of assistance.

If you do not activate your guarantee our Engineer will be entitled to charge full payment for the visit (Call out fee plus parts).

This guarantee is in addition to your statutory rights and is subject to the following conditions:

● The product must be installed and maintained in

accordance with the instructions given in this user

guide.

● Servicing must only be undertaken by us or our

appointed representative.

Note!

if a service visit

is required the product must be fully installed and

connected to services.

● Repair under this guarantee does not extend the original

expiry date. The guarantee on any replacement parts

or product ends at the original expiry date.

● For shower fi ttings or consumable items we reserve

the right to supply replacement parts only.

The guarantee does not cover:

● Call out charges for non product faults (such as damage or performance issues arising from incorrect installation, improper use, lack of maintenance, build up of limescale, frost damage, corrosion, system debris or blocked fi lters) or where no fault has been found with the product.

● Water or electrical supply, waste and isolation issues.

● Compensation for loss of use of the product or consequential loss of any kind.

● Damage or defects caused if the product is repaired or modifi ed by persons not authorised by us or our appointed representative.

● Routine maintenance or replacement parts to comply with the requirements of the TMV 2 or TMV 3 healthcare schemes.

What to do if something goes wrong

If your product does not function correctly when you fi rst use it, contact your installer to check that it is installed and commissioned in accordance with the instructions in this manual. Should this not resolve the issue, contact our

Customer Services Team who will offer you or your installer advice and if applicable arrange for a Service Technician to call. If the performance of your product declines, check in this manual to see if simple home maintenance is required.

If you require further assistance call our Customer Services

Team.

Extended Guarantees

A selection of protection plans are available that enable you to cover repair bills for the life of your policy

(excludes Eire). Ring 01922 471763 for more details.

Helpdesk Service

Our dedicated Customer Services Team is comprehensively trained and can offer help and advice, spare parts, accessories or a service visit. We will need you to have your model name or number, power rating (if applicable) and date of purchase. As part of our quality and training programme calls may be recorded or monitored.

Mira Showers Website

(www.mirashowers.co.uk)

From our website you can register your guarantee, download additional user guides, diagnose faults, purchase our full range of accessories and popular spares, refer to our FAQ’s and request a service visit.

Spares and Accessories

We maintain extensive stocks of genuine spares and accessories and aim to provide support throughout the product’s expected life. Payment can be made by phone at time of order using most major Credit or Debit cards and we aim to despatch orders within two working days. Items purchased from us are guaranteed for 12 months from date of purchase. For safety reasons spares exposed to mains voltages should only be fi tted by competent persons.

Returns

– items can be returned within one month of date of purchase, providing that they are in good condition and the packaging is unopened. Please obtain authorisation from our Customer Services Team before return. We reserve the right to apply a 15% restocking charge.

Service / Repairs

We have a nationwide team of Service Technicians who can carry out all service or repair work to your product within the guarantee period and beyond. You have the assurance of a fully trained Mira Technician, genuine Mira spare parts and a 12 month guarantee on any chargeable work done.

Payment should be made directly to the Service Technician who will accept most major Credit or Debit cards.

To Contact Us

UK

Telephone: 0844 571 5000 www.mirashowers.co.uk

E-mail: [email protected]

Fax: 01242 282595

By Post: Mira Customer Services Dept, Cromwell Road,

Cheltenham, Gloucestershire, GL52 5EP

Eire

Telephone: 01 459 1344

E-mail: [email protected]

Fax: Dublin 01 459 2329

By Post: Modern Plant Ltd (Dublin),

Otter House, Naas Road, Clondalkin, Dublin 22

Mira is a registered trade mark of

Kohler Mira Limited.

The company reserves the right to alter product specifi cations without notice.

1060737-W2-F (1563) (J95A/B/C/V/N)

32

FM 14648

© Kohler Mira Limited, February 2011