HP ProLiant DL365 Server

User Guide

Second Edition (October 2006)

Part Number 418292-002

© Copyright 2006 Hewlett-Packard Development Company, L.P.

The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein.

Microsoft, Windows, and Windows NT are U.S. registered trademarks of Microsoft Corporation. Windows Server 2003 is a trademark of

Microsoft Corporation.

Second Edition (October 2006)

Part Number 418292-002

Audience assumptions

This document is for the person who installs, administers, and troubleshoots servers and storage systems.

HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels.

Contents

Component identification............................................................................................................... 7

Front panel components ............................................................................................................................. 7

Front panel LEDs and buttons ...................................................................................................................... 8

Rear panel components.............................................................................................................................. 9

Rear panel LEDs and buttons..................................................................................................................... 10

System board components........................................................................................................................ 11

System maintenance switch............................................................................................................. 12

NMI jumper.................................................................................................................................. 12

HP Systems Insight Display and LEDs.......................................................................................................... 12

HP Systems Insight Display LEDs and internal health LED combinations ........................................................... 13

SAS and SATA device numbers................................................................................................................. 14

SAS and SATA hard drive LEDs................................................................................................................. 15

SAS and SATA hard drive LED combinations .............................................................................................. 15

Fan locations .......................................................................................................................................... 16

Operations................................................................................................................................. 18

Power up the server ................................................................................................................................. 18

Power down the server............................................................................................................................. 18

Access the HP Systems Insight Display........................................................................................................ 18

Extend the server from the rack ................................................................................................................. 19

Remove the access panel.......................................................................................................................... 20

Install the access panel............................................................................................................................. 20

Remove and install the air baffle ............................................................................................................... 20

Remove the PCI riser board assembly......................................................................................................... 21

Install the PCI riser board assembly............................................................................................................ 22

Remove and install a fan module............................................................................................................... 22

Setup......................................................................................................................................... 24

Optional installation services .................................................................................................................... 24

Rack planning resources........................................................................................................................... 25

Optimum environment.............................................................................................................................. 25

Space and airflow requirements ...................................................................................................... 25

Temperature requirements............................................................................................................... 26

Power requirements ....................................................................................................................... 26

Electrical grounding requirements .................................................................................................... 26

Rack warnings ........................................................................................................................................ 27

Contents of the server shipping carton........................................................................................................ 27

Installing hardware options....................................................................................................................... 27

Installing the server into the rack................................................................................................................ 28

Powering up and configuring the server ..................................................................................................... 29

Installing the operating system................................................................................................................... 29

Registering the server............................................................................................................................... 30

Hardware options installation....................................................................................................... 31

Introduction ............................................................................................................................................ 31

Processor option...................................................................................................................................... 31

Memory options ...................................................................................................................................... 36

Memory configurations................................................................................................................... 37

Advanced ECC memory ................................................................................................................. 37

Installing DIMMs ........................................................................................................................... 37

Hot-plug SAS and SATA hard drive options ................................................................................................ 38

Contents 3

Removing hard drive blanks............................................................................................................ 39

Removing hard drive bezel blanks ................................................................................................... 39

Removing a hot-plug SAS or SATA hard drive ................................................................................... 40

Installing a hot-plug SAS or SATA hard drive .................................................................................... 40

Multibay device options ........................................................................................................................... 41

Redundant hot-plug power supply option.................................................................................................... 42

Expansion board options.......................................................................................................................... 44

Installing an expansion board ......................................................................................................... 44

Installing a PCI-X riser board ........................................................................................................... 45

HP Smart Array controller options.............................................................................................................. 47

Removing an integrated HP Smart Array E200i Controller or an HP Smart Array P400i Controller........... 48

Installing an integrated HP Smart Array E200i Controller or an HP Smart Array P400i Controller ............ 49

Upgrading an HP Smart Array E200i Controller cache module and battery pack................................... 50

Installing an HP Smart Array P400i Controller cache module and battery pack...................................... 53

Upgrading the HP Smart Array P400i Controller to support six hard drives ........................................... 57

Using a PCI SAS or SATA array controller to support six hard drives.................................................... 58

Using a PCI array controller and the HP Smart Array P400i Controller to support six hard drives............. 60

Cabling ..................................................................................................................................... 61

Cabling overview.................................................................................................................................... 61

Array controller cabling ........................................................................................................................... 61

HP Smart Array E200i Controller cabling ......................................................................................... 62

HP Smart Array P400i Controller cabling ......................................................................................... 62

PCI Smart Array controller cabling................................................................................................... 63

Battery pack cabling ...................................................................................................................... 63

Multibay backplane cabling ..................................................................................................................... 64

Configuration and utilities............................................................................................................ 65

Configuration tools .................................................................................................................................. 65

SmartStart software........................................................................................................................ 65

HP ROM-Based Setup Utility............................................................................................................ 66

Array Configuration Utility.............................................................................................................. 67

Option ROM Configuration for Arrays ............................................................................................. 68

HP ProLiant Essentials Rapid Deployment Pack .................................................................................. 68

Re-entering the server serial number and product ID ........................................................................... 68

Management tools................................................................................................................................... 69

Automatic Server Recovery ............................................................................................................. 69

ROMPaq utility.............................................................................................................................. 69

System Online ROM flash component utility ...................................................................................... 69

Integrated Lights-Out 2 technology................................................................................................... 69

Erase Utility .................................................................................................................................. 70

Management Agents...................................................................................................................... 70

HP Systems Insight Manager ........................................................................................................... 70

Redundant ROM support ................................................................................................................ 70

USB support.................................................................................................................................. 71

Internal USB functionality................................................................................................................ 72

Diagnostic tools ...................................................................................................................................... 72

Survey Utility................................................................................................................................. 72

Array Diagnostic Utility .................................................................................................................. 72

HP Insight Diagnostics.................................................................................................................... 73

Integrated Management Log ........................................................................................................... 73

Remote support and analysis tools ............................................................................................................. 73

HP Instant Support Enterprise Edition................................................................................................ 73

Web-Based Enterprise Service......................................................................................................... 74

Contents 4

Open Services Event Manager ........................................................................................................ 74

Keeping the system current ....................................................................................................................... 74

Drivers ......................................................................................................................................... 74

Resource Paqs............................................................................................................................... 74

ProLiant Support Packs ................................................................................................................... 74

Operating system version support .................................................................................................... 74

System Online ROM flash component utility ...................................................................................... 75

Change control and proactive notification ........................................................................................ 75

Care Pack .................................................................................................................................... 75

Troubleshooting .......................................................................................................................... 76

Troubleshooting resources ........................................................................................................................ 76

Pre-diagnostic steps ................................................................................................................................. 76

Important safety information............................................................................................................ 76

Symptom information ..................................................................................................................... 78

Prepare the server for diagnosis ...................................................................................................... 79

Loose connections ................................................................................................................................... 79

Service notifications................................................................................................................................. 79

Troubleshooting flowcharts ....................................................................................................................... 80

Start diagnosis flowchart ................................................................................................................ 80

General diagnosis flowchart ........................................................................................................... 81

Server power-on problems flowchart ................................................................................................ 83

POST problems flowchart ............................................................................................................... 86

OS boot problems flowchart ........................................................................................................... 87

Server fault indications flowchart ..................................................................................................... 89

POST error messages and beep codes ....................................................................................................... 91

Battery replacement .................................................................................................................... 92

Regulatory compliance notices ..................................................................................................... 93

Regulatory compliance identification numbers ............................................................................................. 93

Federal Communications Commission notice............................................................................................... 93

FCC rating label............................................................................................................................ 93

Class A equipment......................................................................................................................... 94

Class B equipment ......................................................................................................................... 94

Declaration of conformity for products marked with the FCC logo, United States only....................................... 94

Modifications.......................................................................................................................................... 95

Cables................................................................................................................................................... 95

Canadian notice (Avis Canadien).............................................................................................................. 95

European Union regulatory notice ............................................................................................................. 95

Disposal of waste equipment by users in private households in the European Union......................................... 96

Japanese notice ...................................................................................................................................... 96

BSMI notice ............................................................................................................................................ 96

Korean notice ......................................................................................................................................... 97

Laser compliance .................................................................................................................................... 97

Battery replacement notice........................................................................................................................ 97

Taiwan battery recycling notice................................................................................................................. 98

Power cord statement for Japan................................................................................................................. 98

Electrostatic discharge................................................................................................................. 99

Preventing electrostatic discharge .............................................................................................................. 99

Grounding methods to prevent electrostatic discharge.................................................................................. 99

Specifications........................................................................................................................... 100

Environmental specifications ................................................................................................................... 100

Contents 5

Server specifications .............................................................................................................................. 100

Technical support...................................................................................................................... 102

Related documents ................................................................................................................................ 102

HP contact information........................................................................................................................... 102

Customer Self Repair ............................................................................................................................. 102

Acronyms and abbreviations...................................................................................................... 110

Index....................................................................................................................................... 114

Contents 6

Component identification

In this section

Front panel components ............................................................................................................................ 7

Front panel LEDs and buttons..................................................................................................................... 8

Rear panel components............................................................................................................................. 9

Rear panel LEDs and buttons ................................................................................................................... 10

System board components....................................................................................................................... 11

HP Systems Insight Display and LEDs ........................................................................................................ 12

HP Systems Insight Display LEDs and internal health LED combinations ......................................................... 13

SAS and SATA device numbers ............................................................................................................... 14

SAS and SATA hard drive LEDs ............................................................................................................... 15

SAS and SATA hard drive LED combinations............................................................................................. 15

Fan locations ......................................................................................................................................... 16

Front panel components

3

4

Item Description

1 Hard drive bay 5 (optional)*

2 Hard drive bay 6 (optional)*

Multibay drive bay

HP Systems Insight Display

7 Hard drive bay 4

Component identification 7

Item Description

8 Hard drive bay 3

9 Hard drive bay 2

10 Hard drive bay 1

11 Serial pull tab

*An optional controller is required when the server is configured with six hard drives.

Front panel LEDs and buttons

Item Description

1 Power On/Standby button and system power LED

2

3

4

UID button/LED

Internal health LED

External health LED

(power supply)

Status

Green = System is on.

Amber = System is shut down, but power is still applied.

Off = Power cord is not attached, power supply failure has occurred, no power supplies are installed, facility power is not available, or disconnected power button cable.

Blue = Identification is activated.

Flashing blue = System is being remotely managed.

Off = Identification is deactivated.

Green = System health is normal.

Amber = System health is degraded. To identify the component in a degraded state, refer to "HP Systems Insight Display and LEDs".

Red = System health is critical. To identify the component in a critical state, refer to "HP Systems Insight Display and LEDs".

Off = System health is normal (when in standby mode).

Green = Power supply health is normal.

Amber = Power redundancy failure occurred.

Off = Power supply health is normal when in standby mode.

Component identification 8

Item Description

5 NIC 1 link/activity LED

6 NIC 2 link/activity LED

Rear panel components

Status

Green = Network link exists.

Flashing green = Network link and activity exist.

Off = No link to network exists.

If power is off, the front panel LED is not active. View the LEDs on the RJ-45 connector for status by referring to the rear panel LEDs

(" Rear panel LEDs and buttons " on page 10 ).

Green = Network link exists.

Flashing green = Network link and activity exist.

Off = No link to network exists.

If power is off, the front panel LED is not active. View the LEDs on the RJ-45 connector for status by referring to the rear panel LEDs

(" Rear panel LEDs and buttons " on page 10 ).

5

6

2

3

Item Description

1 PCI Express expansion slot 1, low-profile, half-length

4

PCI Express expansion slot 2

Power supply bay 2

Power supply bay 1

NIC 2 connector

NIC 1 connector

Component identification 9

Item Description

13 iLO 2 NIC connector

Rear panel LEDs and buttons

Item Description Status

1

2 iLO 2 NIC activity

LED iLO 2 NIC link

LED

Green = Activity exists.

Flashing green = Activity exists.

Off = No activity exists.

Green = Link exists.

Off = No link exists.

NIC 1 activity LED Flashing green = Activity exists.

Off = No activity exists.

7

8

9

NIC 1 link LED

Power supply 2

LED

Power supply 1

LED

Off = No link exists.

NIC 2 activity LED Flashing green = Activity exists.

Off = No activity exists.

NIC 2 link LED

UID button/LED

Off = No link exists.

Blue = Identification is activated.

Flashing blue = System is being managed remotely.

Off = Identification is deactivated.

Green = Normal

Off = System is off or power supply has failed

Green = Normal

Off = System is off or power supply has failed

Component identification 10

System board components

3

4

13

14

15

16

17

18

19

6

7

8

9

10

11

12

Item Description

System maintenance switch (SW1)

Internal USB connector

Power switch connector

DIMM slots (1-4)

Fan module 3 connectors

Fan module 2 connectors

DIMM slots (5-8)

Fan module 1 connectors

SFF hard drive backplane power connector

Integrated Smart Array controller connector

Power supply connector 1

Power supply connector 2

Processor socket 2

Processor socket 1 (populated)

PCI riser board connector 2

PCI riser board connector 1

Component identification 11

System maintenance switch

S1 Off

S2 Off

Off = iLO 2 security is enabled.

On = iLO 2 security is disabled.

Off = System configuration can be modified.

On = System configuration is locked and cannot be modified.

S5

S6

Off

Off

Off = Power-on password is enabled.

On = Power-on password is disabled.

Off = Normal

On = ROM treats system configuration as invalid.

When the system maintenance switch position 6 is set to the On position, the system is prepared to erase all system configuration settings from both CMOS and NVRAM.

CAUTION: Clearing CMOS and/or NVRAM deletes configuration information. Be sure to properly configure the server or data loss could occur.

NMI jumper

The NMI jumper allows administrators to perform a memory dump before performing a hard reset. Crash dump analysis is an essential part of eliminating reliability problems, such as hangs or crashes in OSs, device drivers, and applications. Many crashes can freeze a system, requiring you to do a hard reset.

Resetting the system erases any information that would support root cause analysis.

Systems running Microsoft® Windows® experience a blue-screen trap when the OS crashes. When this happens, Microsoft® recommends that system administrators perform an NMI event by temporarily shorting the NMI header with a jumper. The NMI event enables a hung system to become responsive again.

HP Systems Insight Display and LEDs

The display provides status for all internal LEDs and enables diagnosis with the access panel installed.

Component identification 12

To view the LEDs, access the HP Systems Insight Display (on page 18 ).

LED Status

Off Normal

Amber Failure

For additional information about these LEDs, see "HP Systems Insight Display LEDs and internal health LED combinations (on page 13 )."

NOTE: The HP Systems Insight Display LEDs represent the system board layout.

HP Systems Insight Display LEDs and internal health LED combinations

When the internal health LED on the front panel illuminates either amber or red, the server is experiencing a health event. Combinations of illuminated system LEDs and the internal health LED indicate system status.

The front panel health LEDs indicate only the current hardware status. In some situations, HP SIM may report server status differently than the health LEDs because the software tracks more system attributes.

HP Systems Insight

Display LED and color

Internal health LED color

Status

Processor failure, socket X

(amber)

Red

Amber

One or more of the following conditions may exist:

• Processor in socket X has failed.

• Processor X is required yet not installed in the socket.

• Processor X is unsupported.

Processor in socket X is in a pre-failure condition.

Processor failure, both sockets (amber)

PPM failure (amber)

Red

Red

Processor types are mismatched.

Integrated PPM has failed.

Component identification 13

HP Systems Insight

Display LED and color

DIMM failure, slot X

(amber)

DIMM failure, all slots

(amber)

Internal health LED color

Red

Amber

Red

Overtemperature (amber) Amber

Status

One or more of the following conditions may exist:

DIMM in slot X has failed.

• DIMM in slot X is an unsupported type, and no valid memory exists in another bank.

One or more of the following conditions may exist:

DIMM in slot X has reached single-bit correctable error threshold.

DIMM in slot X is in a pre-failure condition.

• DIMM in slot X is an unsupported type, but valid memory exists in another bank.

No valid or usable memory is installed in the system.

Riser interlock (amber)

Fan module (amber)

Fan module (amber)

Red

Red

Amber

Red

The health driver has detected a cautionary temperature level.

The server has detected a critical temperature level.

The PCI riser board assembly is not seated properly.

A redundant fan has failed.

The minimum fan requirements are not being met in one or more of the fan modules. One or more fans have failed or are missing.

SAS and SATA device numbers

Four hard drive configuration

Component identification 14

Six hard drive configuration

SAS and SATA hard drive LEDs

Item Description

1 Fault/UID LED (amber/blue)

Online LED (green) 2

SAS and SATA hard drive LED combinations

Online/activity LED

(green)

Fault/UID LED

(amber/blue)

Interpretation

On, off, or flashing Alternating amber and blue

The drive has failed, or a predictive failure alert has been received for this drive; it also has been selected by a management application.

Component identification 15

Online/activity LED

(green)

On

Fault/UID LED

(amber/blue)

On, off, or flashing Steadily blue

Amber, flashing regularly (1 Hz)

Interpretation

The drive is operating normally, and it has been selected by a management application.

A predictive failure alert has been received for this drive.

Replace the drive as soon as possible.

The drive is online, but it is not active currently. On

Flashing regularly

(1 Hz)

Flashing regularly

(1 Hz)

Off

Amber, flashing regularly (1 Hz)

Off

Flashing irregularly Amber, flashing regularly (1 Hz)

Do not remove the drive. Removing a drive may

terminate the current operation and cause data loss.

The drive is part of an array that is undergoing capacity expansion or stripe migration, but a predictive failure alert has been received for this drive. To minimize the risk of data loss, do not replace the drive until the expansion or migration is complete.

Do not remove the drive. Removing a drive may

terminate the current operation and cause data loss.

The drive is rebuilding, or it is part of an array that is undergoing capacity expansion or stripe migration.

The drive is active, but a predictive failure alert has been received for this drive. Replace the drive as soon as possible.

Flashing irregularly Off The drive is active, and it is operating normally. amber the controller has placed it offline. Replace the drive as soon as possible.

Off Amber, flashing regularly (1 Hz)

A predictive failure alert has been received for this drive.

Replace the drive as soon as possible.

Off Off The drive is offline, a spare, or not configured as part of an array.

Fan locations

Component identification 16

Item Description

1 Fan module 1

2

3

Fan module 2

Fan module 3

Component identification 17

Operations

In this section

Power up the server................................................................................................................................ 18

Power down the server............................................................................................................................ 18

Access the HP Systems Insight Display ...................................................................................................... 18

Extend the server from the rack ................................................................................................................ 19

Remove the access panel ........................................................................................................................ 20

Install the access panel ........................................................................................................................... 20

Remove and install the air baffle .............................................................................................................. 20

Remove the PCI riser board assembly ....................................................................................................... 21

Install the PCI riser board assembly .......................................................................................................... 22

Remove and install a fan module.............................................................................................................. 22

Power up the server

To power up the server, press the Power On/Standby button.

Power down the server

WARNING: To reduce the risk of personal injury, electric shock, or damage to the

equipment, remove the power cord to remove power from the server. The front panel

Power On/Standby button does not completely shut off system power. Portions of the

power supply and some internal circuitry remain active until AC power is removed.

IMPORTANT: If installing a hot-plug device, it is not necessary to power down the server.

1.

2.

3.

4.

5.

6.

Back up the server data.

Shut down the operating system as directed by the operating system documentation.

If the server is installed in a rack, press the UID LED button on the front panel. Blue LEDs illuminate on the front and rear panels of the server.

Press the Power On/Standby button to place the server in standby mode. When the server activates standby power mode, the system power LED changes to amber.

If the server is installed in a rack, locate the server by identifying the illuminated rear UID LED button.

Disconnect the power cords.

The system is now without power.

Access the HP Systems Insight Display

To eject the HP Systems Insight Display:

1.

Press and release the display.

Operations 18

2.

Extend the display from the chassis.

The display can be rotated up to 90 degrees.

Extend the server from the rack

NOTE: If the optional cable management arm option is installed, you can extend the server without powering down the server or disconnecting peripheral cables and power cords. These steps are only necessary with the standard cable management solution.

1.

2.

Power down the server (on page 18 ).

Disconnect all peripheral cables and power cords.

3.

4.

Loosen the front panel thumbscrews.

Extend the server on the rack rails until the server rail-release latches engage.

WARNING: To reduce the risk of personal injury or equipment damage, be sure that the

rack is adequately stabilized before extending a component from the rack.

Operations 19

WARNING: To reduce the risk of personal injury, be careful when pressing the server

rail-release latches and sliding the server into the rack. The sliding rails could pinch your

fingers.

5.

After performing the installation or maintenance procedure, slide the server into the rack:

6. a.

Slide the server fully into the rack.

b.

Secure the server by tightening the thumbscrews.

Connect the peripheral cables and power cords.

Remove the access panel

WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and

the internal system components to cool before touching them.

CAUTION: Do not operate the server for long periods with the access panel open or removed. Operating the server in this manner results in improper airflow and improper cooling that can lead to thermal damage.

1.

Power down the server if the standard cable management solution is installed (" Power down the server " on page 18 ).

NOTE: If the optional cable management arm is installed, you can extend the server and perform hot-plug installation or maintenance procedures without powering down the server.

2.

3.

Extend or remove the server from the rack (" Extend the server from the rack " on page 19 ).

Lift up on the hood latch handle and remove the access panel.

Install the access panel

1.

2.

3.

Place the access panel on top of the server with the hood latch open. Allow the panel to extend past the rear of the server approximately 0.8 cm (0.2 in).

Engage the anchoring pin with the corresponding hole in the latch.

Push down on the hood latch. The access panel slides to a closed position.

Remove and install the air baffle

1.

2.

3.

Power down the server (on page 18 ).

Extend or remove the server from the rack (" Extend the server from the rack " on page 19 ).

Remove the access panel (on page 20 ).

Operations 20

4.

Remove the air baffle.

To install the component, reverse the removal procedure.

Remove the PCI riser board assembly

CAUTION: To prevent damage to the server or expansion boards, power down the server and remove all

AC power cords before removing or installing the PCI riser board assembly.

1.

2.

Power down the server (on page 18 ).

Extend or remove the server from the rack (" Extend the server from the rack " on page 19 ).

3.

4.

Remove the access panel (on page 20 ).

Remove the PCI riser board assembly:

a. b.

Disconnect any external cables connected to any existing expansion boards.

Loosen the four PCI riser board assembly thumbscrews.

c.

Lift the assembly to unseat the PCI riser boards and remove the assembly.

Operations 21

To replace the component, reverse the removal procedure.

Install the PCI riser board assembly

CAUTION: To prevent damage to the server or expansion boards, power down the server and remove all

AC power cords before removing or installing the PCI riser board assembly.

1.

2.

Align the PCI riser boards with the corresponding connectors on the system board and install the assembly.

Tighten the four PCI riser board assembly thumbscrews.

Remove and install a fan module

The server has three fan modules.

To remove a fan module:

1.

Power down the server (on page 18 ).

2.

3.

Extend or remove the server from the rack (" Extend the server from the rack " on page 19 ).

Remove the access panel (on page 20 ).

4.

Remove the air baffle (" Remove and install the air baffle " on page 20 ).

Operations 22

5.

Remove a fan module.

To install a fan module, reverse the removal procedures.

IMPORTANT: After installing the fan module, firmly press the top of the module connectors to ensure the connectors are seated properly.

Operations 23

Setup

In this section

Optional installation services ................................................................................................................... 24

Rack planning resources ......................................................................................................................... 25

Optimum environment............................................................................................................................. 25

Rack warnings ....................................................................................................................................... 27

Contents of the server shipping carton ...................................................................................................... 27

Installing hardware options ..................................................................................................................... 27

Installing the server into the rack .............................................................................................................. 28

Powering up and configuring the server.................................................................................................... 29

Installing the operating system ................................................................................................................. 29

Registering the server.............................................................................................................................. 30

Optional installation services

Delivered by experienced, certified engineers, HP Care Pack services help you keep your servers up and running with support packages tailored specifically for HP ProLiant systems. HP Care Packs let you integrate both hardware and software support into a single package. A number of service level options are available to meet your needs.

HP Care Pack Services offer upgraded service levels to expand your standard product warranty with easyto-buy, easy-to-use support packages that help you make the most of your server investments. Some of the

Care Pack services are:

Hardware support

6-Hour Call-to-Repair

4-Hour 24x7 Same Day

4-Hour Same Business Day

Software support

Microsoft®

Linux

HP ProLiant Essentials (HP SIM and RDP)

VMWare

Integrated hardware and software support

Critical Service

Proactive 24

Support Plus

Support Plus 24

Startup and implementation services for both hardware and software

For more information on Care Packs, refer to the HP website

( http://www.hp.com/hps/carepack/servers/cp_proliant.html

).

Setup 24

Rack planning resources

The rack resource kit ships with all HP branded or Compaq branded 9000, 10000, and H9 series racks.

For more information on the content of each resource, refer to the rack resource kit documentation.

If you intend to deploy and configure multiple servers in a single rack, refer to the white paper on highdensity deployment at the HP website ( http://www.hp.com/products/servers/platforms ).

Optimum environment

When installing the server in a rack, select a location that meets the environmental standards described in this section.

Space and airflow requirements

To allow for servicing and adequate airflow, observe the following space and airflow requirements when deciding where to install a rack:

Leave a minimum clearance of 63.5 cm (25 in) in front of the rack.

Leave a minimum clearance of 76.2 cm (30 in) behind the rack.

Leave a minimum clearance of 121.9 cm (48 in) from the back of the rack to the back of another rack or row of racks.

HP servers draw in cool air through the front door and expel warm air through the rear door. Therefore, the front and rear rack doors must be adequately ventilated to allow ambient room air to enter the cabinet, and the rear door must be adequately ventilated to allow the warm air to escape from the cabinet.

CAUTION: To prevent improper cooling and damage to the equipment, do not block the ventilation openings.

When vertical space in the rack is not filled by a server or rack component, the gaps between the components cause changes in airflow through the rack and across the servers. Cover all gaps with blanking panels to maintain proper airflow.

CAUTION: Always use blanking panels to fill empty vertical spaces in the rack. This arrangement ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage.

The 9000 and 10000 Series Racks provide proper server cooling from flow-through perforations in the front and rear doors that provide 64 percent open area for ventilation.

CAUTION: When using a Compaq branded 7000 Series rack, you must install the high airflow rack door insert [P/N 327281-B21 (42U) or P/N 157847-B21 (22U)] to provide proper front-to-back airflow and cooling.

CAUTION: If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to prevent damage to the equipment:

• Front and rear doors—If the 42U rack includes closing front and rear doors, you must allow 5,350 sq cm (830 sq in) of holes evenly distributed from top to bottom to permit adequate airflow (equivalent to the required 64 percent open area for ventilation).

• Side—The clearance between the installed rack component and the side panels of the rack must be a minimum of 7 cm (2.75 in).

Setup 25

Temperature requirements

To ensure continued safe and reliable equipment operation, install or position the system in a wellventilated, climate-controlled environment.

The maximum recommended ambient operating temperature (TMRA) for most server products is 35°C

(95°F). The temperature in the room where the rack is located must not exceed 35°C (95°F).

CAUTION: To reduce the risk of damage to the equipment when installing third-party options:

• Do not permit optional equipment to impede airflow around the server or to increase the internal rack temperature beyond the maximum allowable limits.

• Do not exceed the manufacturer’s TMRA.

Power requirements

Installation of this equipment must comply with local and regional electrical regulations governing the installation of information technology equipment by licensed electricians. This equipment is designed to operate in installations covered by NFPA 70, 1999 Edition (National Electric Code) and NFPA-75, 1992

(code for Protection of Electronic Computer/Data Processing Equipment). For electrical power ratings on options, refer to the product rating label or the user documentation supplied with that option.

WARNING: To reduce the risk of personal injury, fire, or damage to the equipment, do

not overload the AC supply branch circuit that provides power to the rack. Consult the electrical authority having jurisdiction over wiring and installation requirements of your

facility.

CAUTION: Protect the server from power fluctuations and temporary interruptions with a regulating uninterruptible power supply (UPS). This device protects the hardware from damage caused by power surges and voltage spikes and keeps the system in operation during a power failure.

When installing more than one server, you may need to use additional power distribution devices to safely provide power to all devices. Observe the following guidelines:

Balance the server power load between available AC supply branch circuits.

Do not allow the overall system AC current load to exceed 80 percent of the branch circuit AC current rating.

Do not use common power outlet strips for this equipment.

Provide a separate electrical circuit for the server.

For more information on the hot-plug power supply and calculators to determine server power consumption in various system configurations, refer to the HP Enterprise Configurator website

( http://h30099.www3.hp.com/configurator/ ).

Electrical grounding requirements

The server must be grounded properly for proper operation and safety. In the United States, you must install the equipment in accordance with NFPA 70, 1999 Edition (National Electric Code), Article 250, as well as any local and regional building codes. In Canada, you must install the equipment in accordance with Canadian Standards Association, CSA C22.1, Canadian Electrical Code. In all other countries, you must install the equipment in accordance with any regional or national electrical wiring codes, such as the International Electrotechnical Commission (IEC) Code 364, parts 1 through 7.

Furthermore, you must be sure that all power distribution devices used in the installation, such as branch wiring and receptacles, are listed or certified grounding-type devices.

Because of the high ground-leakage currents associated with multiple servers connected to the same power source, HP recommends the use of a PDU that is either permanently wired to the building’s branch

Setup 26

circuit or includes a nondetachable cord that is wired to an industrial-style plug. NEMA locking-style plugs or those complying with IEC 60309 are considered suitable for this purpose. Using common power outlet strips for the server is not recommended.

Rack warnings

WARNING: To reduce the risk of personal injury or damage to the equipment, be sure

that:

The leveling jacks are extended to the floor.

The full weight of the rack rests on the leveling jacks.

The stabilizing feet are attached to the rack if it is a single-rack installation.

The racks are coupled together in multiple-rack installations.

Only one component is extended at a time. A rack may become unstable if more than

one component is extended for any reason.

WARNING: To reduce the risk of personal injury or equipment damage when unloading

a rack:

At least two people are needed to safely unload the rack from the pallet. An empty

42U rack can weigh as much as 115 kg (253 lb), can stand more than 2.1 m (7 ft)

tall, and may become unstable when being moved on its casters.

Never stand in front of the rack when it is rolling down the ramp from the pallet.

Always handle the rack from both sides.

Contents of the server shipping carton

Unpack the server shipping carton and locate the materials and documentation necessary for installing the server. All the rack mounting hardware necessary for installing the server into the rack is included with the rack or the server.

The contents of the server shipping carton include:

Server

Power cord

Printed setup documentation, Documentation CD, and software products

Rack mounting hardware kit and documentation

In addition to these supplied items, you may need:

T-15 Torx screwdriver

Hardware options

Operating system or application software

Installing hardware options

Install any hardware options before initializing the server. For options installation information, refer to the option documentation. For server-specific information, refer to "Hardware options installation (on page

31 )."

Setup 27

Installing the server into the rack

To install the server into a rack with square, round, or threaded holes, refer to the instructions that ship with the rack hardware kit.

If you are installing the server into a telco rack, order the appropriate option kit at the RackSolutions.com website ( http://www.racksolutions.com/hp ). Follow the server-specific instructions on the website to install the rack brackets.

Use the following information when connecting peripheral cables and power cords to the server.

WARNING: This server is very heavy. To reduce the risk of personal injury or damage to

the equipment:

Observe local occupational health and safety requirements and guidelines for manual

material handling.

Get help to lift and stabilize the product during installation or removal, especially

when the product is not fastened to the rails. When the server weighs more than 22.5 kg (50 lb), at least two people must lift the server into the rack together. A third person may be required to help align the server if the server is installed higher than chest level.

Use caution when installing the server in or removing the server from the rack; it is

unstable when not fastened to the rails.

CAUTION: Always plan the rack installation so that the heaviest item is on the bottom of the rack. Install the heaviest item first, and continue to populate the rack from the bottom to the top.

1.

2.

Install the server and cable management arm into the rack. Refer to the installation instructions that ship with the HP 1U Quick Deploy Rail System.

Connect the peripheral devices to the server.

3

4

5

Item Description

1

2

PCI Express expansion slot 1, low-profile, half-length

PCI Express expansion slot 2

Power supply bay 2

Power supply bay 1

NIC 2 connector

Setup 28

Item Description

6 NIC 1 connector

13

3.

iLO 2 NIC connector

Use the strain relief clip from the server hardware kit to secure the power cord.

Powering up and configuring the server

To power up the server, press the Power On/Standby button.

While the server boots, RBSU and the ORCA utility are automatically configured to prepare the server for operating system installation.

To configure these utilities manually:

Press the F8 key when prompted during the array controller initialization to configure the array controller using ORCA.

Press the F9 key when prompted during the boot process to change the server settings using RBSU.

The system is set up by default for the English language.

For more information on the automatic configuration, refer to the HP ROM-Based Setup Utility User Guide located on the Documentation CD.

Installing the operating system

To operate properly, the server must have a supported operating system. For the latest information on supported operating systems, refer to the HP website ( http://www.hp.com/go/supportos ).

Two methods are available to install an operating system on the server:

Setup 29

SmartStart assisted installation—Insert the SmartStart CD into the CD-ROM drive and reboot the server.

Manual installation—Insert the operating system CD into the CD-ROM drive and reboot the server.

This process may require you to obtain additional drivers from the HP website

( http://www.hp.com/support ).

Follow the on-screen instructions to begin the installation process.

For information on using these installation paths, refer to the SmartStart installation poster in the HP

ProLiant Essentials Foundation Pack, included with the server.

Registering the server

To register the server, refer to the HP Registration website ( http://register.hp.com

).

Setup 30

Hardware options installation

In this section

Introduction ........................................................................................................................................... 31

Processor option..................................................................................................................................... 31

Memory options..................................................................................................................................... 36

Hot-plug SAS and SATA hard drive options............................................................................................... 38

Multibay device options .......................................................................................................................... 41

Redundant hot-plug power supply option................................................................................................... 42

Expansion board options ........................................................................................................................ 44

HP Smart Array controller options ............................................................................................................ 47

Introduction

If more than one option is being installed, read the installation instructions for all the hardware options and identify similar steps to streamline the installation process.

WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and

the internal system components to cool before touching them.

CAUTION: To prevent damage to electrical components, properly ground the server before beginning any installation procedure. Improper grounding can cause electrostatic discharge.

Processor option

The server supports single- and dual-processor operation. With two processors installed, the server supports boot functions through the processor installed in processor socket 1.

The server uses embedded PPMs as DC-to-DC converters to provide the proper power to each processor.

WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and

the internal system components to cool before touching them.

CAUTION: To prevent possible server malfunction and damage to the equipment, multiprocessor configurations must contain processors with the same part number.

CAUTION: To avoid damage to the processor and system board, only authorized personnel should attempt to replace or install the processor in this server.

CAUTION: To avoid damage to the system board:

• Do not touch the processor socket contacts.

• Always install the processor socket cover after removing the processor from the socket.

• Do not tilt or slide the processor when lowering the processor into the socket.

CAUTION: To avoid damage to the processor:

• Handle the processor only by the edges.

• Do not touch the bottom of the processor, especially the contact area.

Hardware options installation 31

CAUTION: To help avoid damage to the processor and system board, do not install the processor without using the processor installation tool.

CAUTION: To prevent possible server malfunction, do not mix processors of different speeds or cache sizes. Refer to the label on the processor heatsink for a description of the processor.

CAUTION: Removal of the processor or heatsink renders the thermal layer between the processor and heatsink useless. A new heatsink must be ordered and installed before reinstalling the processor.

IMPORTANT: Processor socket 1 must be populated at all times or the server does not function.

IMPORTANT: If upgrading processor speed, update the system ROM before installing the processor.

1.

2.

3.

4.

Power down the server (on page 18 ).

Extend the server from the rack (on page 19 ).

Remove the access panel (on page 20 ).

Remove the air baffle (" Remove and install the air baffle " on page 20 ).

CAUTION: The pins on the processor socket are very fragile. Any damage to them may require replacing the system board.

5.

Remove the processor socket protective cover. Retain the cover for future use.

CAUTION: Failure to completely open the processor locking lever prevents the processor from seating during installation, leading to hardware damage.

Hardware options installation 32

6.

Rotate the latch and open the retaining bracket.

IMPORTANT: Be sure the processor remains inside the processor installation tool.

7.

If the processor has separated from the installation tool, carefully re-insert the processor in the tool.

8.

Align the processor installation tool with the socket and install the processor.

Hardware options installation 33

CAUTION: The processor is designed to fit one way into the socket. Use the alignment guides on the processor and socket to properly align the processor with the socket.

9.

Press down firmly until the processor installation tool clicks and separates from the processor, and then remove the processor installation tool.

Hardware options installation 34

10.

Close the processor retaining bracket and the processor retaining latch.

11.

Open the heatsink retaining latches.

Hardware options installation 35

12.

Remove the heatsink protective cover.

13.

Install the heatsink.

14.

15.

16.

17.

Install the air baffle (" Remove and install the air baffle " on page 20 ).

Install the access panel (on page 20 ).

Slide the server into the rack.

Power up the server (on page 18 ).

Memory options

This server contains eight DIMM slots. You can expand server memory by installing PC2-5300 Registered

DDR2 DIMMs. The server supports up to 32 GB of memory using eight 4-GB DIMMs (4 DIMMs per processor).

Refer to "DIMM slots" for DIMM slot locations and bank assignments.

Hardware options installation 36

Memory configurations

The memory subsystem for this server is divided into two branches. Each memory branch is essentially a separate memory controller. The DIMMs map to the two branches as indicated in the following table:

DIMM slot DIMM slot

DIMM 1A DIMM 5C

DIMM 2A

DIMM 3B

DIMM 4B

DIMM 6C

DIMM 7D

DIMM 8D

If the server contains more than 4 GB of memory, consult the operating system documentation about accessing the full amount of installed memory.

Advanced ECC memory

Advanced ECC memory is the default memory protection mode for this server. In Advanced ECC, the server is protected against correctable memory errors. The server provides notification if the level of correctable errors exceeds a pre-defined threshold rate. The server does not fail because of correctable memory errors. Advanced ECC provides additional protection over Standard ECC because it is possible to correct certain memory errors that would otherwise be uncorrectable and result in a server failure.

Whereas standard ECC can correct single-bit memory errors, Advanced ECC can correct single-bit memory errors and multi-bit memory errors if all failed bits are on the same DRAM device on the DIMM.

In addition to general configuration requirements, Advanced ECC memory also has the following configuration requirement:

DIMMs must be installed in pairs.

DIMM pairs in a memory bank must have identical HP part numbers.

In Advanced ECC mode, DIMMs must be populated as specified in the following table:

Bank B Bank C Bank D

1A and 2A 3B and 4B 5C and 6C 7D and 8D

Single-processor

Dual-processor

1st

1st

2nd

3rd

2nd

4th

Installing DIMMs

1.

2.

3.

4.

Power down the server (on page 18 ).

Extend the server from the rack, if applicable ("

Extend the server from the rack " on page 19 ).

Remove the access panel (on page 20 ).

Open the DIMM slot latches.

Hardware options installation 37

5.

Install the DIMM.

6.

Install the access panel (on page 20 ).

Hot-plug SAS and SATA hard drive options

When adding hard drives to the server, observe the following general guidelines:

The system automatically sets all device numbers.

If only one hard drive is used, install it in the bay with the lowest device number ("

SAS and SATA device numbers " on page 14 ).

Hard drives must be SFF types.

Drives should be the same capacity to provide the greatest storage space efficiency when drives are grouped together into the same drive array.

Hardware options installation 38

Removing hard drive blanks

CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank.

Removing hard drive bezel blanks

CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank.

To remove the component:

1.

Remove hard drives 1 and 2 (" Removing a hot-plug SAS or SATA hard drive " on page 40 ).

2.

Remove the hard drive bezel blank.

Hardware options installation 39

Removing a hot-plug SAS or SATA hard drive

CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank.

Installing a hot-plug SAS or SATA hard drive

1.

2.

Remove one of the following:

Hard drive blank (" Removing hard drive blanks " on page 39 )

Hot-plug hard drive ("

Prepare the hard drive.

Removing a hot-plug SAS or SATA hard drive " on page 40 )

Hardware options installation 40

3.

Install the hot-plug hard drive.

4.

5.

Determine the status of the hot-plug hard drive by observing the drive LEDs (" SAS and SATA hard drive LED combinations " on page 15 ).

Resume normal server operations.

Multibay device options

Several multibay devices can be installed in the server. For a list of supported multibay devices, refer to the QuickSpecs on the HP website ( http://www.hp.com/support ).

To install the component:

1.

Power down the server (on page 18 ).

NOTE: Access to the ejector button is intentionally restricted. To eject the optical device, push the ejector button with a small flat object such as a key or pen.

2.

Push the multibay drive ejector button to eject the device or blank.

Hardware options installation 41

CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank.

IMPORTANT: After removing a blank, save it for future use.

3.

Install the multibay device fully into the bay until it clicks.

Redundant hot-plug power supply option

CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless all bays are populated with either a component or a blank.

To install the component:

1.

Unfasten the cable management solution to access the power supply bays.

Hardware options installation 42

2.

Remove the power supply blank.

3.

Remove the protective cover from the connector pins on the power supply.

WARNING: To reduce the risk of electric shock or damage to the equipment, do not

connect the power cord to the power supply until the power supply is installed.

Hardware options installation 43

4.

Install the redundant power supply into the bay until it clicks.

5.

6.

Connect the power cord to the power supply.

Use the strain relief clip from the server hardware kit to secure the power cord.

7.

8.

9.

10.

Route the power cord through the cable management solution.

Connect the power cord to the power source.

Be sure that the power supply LED is green (" Rear panel LEDs and buttons " on page 10 ).

Be sure that the front panel external health LED is green (" Front panel LEDs and buttons " on page 8 ).

Expansion board options

Installing an expansion board

The server ships with PCI Express slots. PCI or PCI-X expansion boards are supported with optional riser boards.

Hardware options installation 44

To install the component:

1.

Power down the server (on page 18 ).

2.

Extend the server from the rack (on page 19 ).

3.

Remove the access panel (on page 20 ).

4.

Remove the air baffle (" Remove and install the air baffle " on page 20 ).

5.

Remove the PCI riser board assembly (on page 21 ).

6.

Remove the expansion slot cover from the PCI riser board assembly.

IMPORTANT: If the expansion board ships with an extender bracket, remove it from the expansion board before inserting the board into the expansion slot of the PCI riser board assembly.

7.

Install the expansion board into the slot until it seats firmly.

8.

Install the PCI riser board assembly (on page 22

).

IMPORTANT: The server does not power up if the PCI riser board assembly is not seated properly.

NOTE: The same procedures apply for installing an expansion board in PCI expansion slot 1.

9.

10.

11.

12.

13.

Connect any internal or external cabling to the expansion boards.

Install the air baffle (" Remove and install the air baffle " on page 20 ).

Install the access panel (on page 20 ).

Slide the server into the rack.

Power up the server (on page 18 ).

Installing a PCI-X riser board

1.

2.

3.

4.

5.

Power down the server (on page 18 ).

Extend the server from the rack (on page 19 ).

Remove the access panel (on page 20 ).

Remove the air baffle (" Remove and install the air baffle " on page 20 ).

Remove the PCI riser board assembly (on page 21 ).

Hardware options installation 45

6.

Remove the expansion board from the slot, if installed.

7.

Remove the full-length PCI Express riser board from the riser board assembly.

Hardware options installation 46

8.

Install the PCI-X riser board on the riser board assembly.

9.

10.

11.

12.

13.

14.

Install a PCI-X expansion board (" Installing an expansion board " on page 44 ).

Install the PCI riser board assembly.

Install the air baffle (" Remove and install the air baffle " on page 20 ).

Install the access panel (on page 20 ).

Slide the server into the rack.

Power up the server (on page 18 ).

HP Smart Array controller options

The server supports two integrated Smart Array controllers. Upgrade options exist for both integrated array controllers.

HP Smart

Array E200i

Controller

HP Smart

Array P400i

Controller

PCI controller PCI controller and P400i

Channel A

drives

Channel B drives None 5-6* 5-6 5-6 (P400i)

256 MB None 256 MB Standard cache 64 MB

Standard

battery

Optional cache 128 MB

Optional battery Yes

*Available in some configurations.

512 MB

Yes

None

Yes

None

Yes

For a list of supported options, see the QuickSpecs on the HP website ( http://www.hp.com/support ).

For instructions on installing optional configurations see the procedures in this guide:

Upgrading an HP Smart Array E200i Controller cache module and battery pack (on page 50 )

Installing an HP Smart Array P400i Controller cache module and battery pack (on page 53 )

Upgrading the HP Smart Array P400i Controller to support six hard drives (on page 57 )

Hardware options installation 47

Using a PCI SAS or SATA array controller to support six hard drives (on page 58 )

Using a PCI array controller and the HP Smart Array P400i Controller to support six hard drives (on

page 60 )

The Battery-Backed Write Cache Enabler, also called the battery pack, works with the cache module to provide transportable data protection, increase overall controller performance, and maintain any cached data for up to 72 hours. The NiMH batteries in the battery pack are continuously recharged through a trickle-charging process whenever the system power is on. Under normal operating conditions, the battery pack lasts for 3 years before replacement is necessary.

CAUTION: To prevent a server malfunction or damage to the equipment, do not add or remove the battery pack while an array capacity expansion, RAID level migration, or stripe size migration is in progress.

CAUTION: After the server is powered down, wait 15 seconds and then check the amber LED before unplugging the cable from the cache module. If the amber LED blinks after 15 seconds, do not remove the cable from the cache module. The cache module is backing up data, and data is lost if the cable is detached.

IMPORTANT: The battery pack might have a low charge when installed. In this case, a POST error message is displayed when the server is powered up, indicating that the battery pack is temporarily disabled. No action is necessary on your part. The internal circuitry automatically recharges the batteries and enables the battery pack. This process might take up to four hours. During this time, the cache module functions properly, but without the performance advantage of the battery pack.

NOTE: The data protection and the time limit also apply if a power outage occurs. When power is restored to the system, an initialization process writes the preserved data to the hard drives.

Removing an integrated HP Smart Array E200i Controller or an HP Smart Array

P400i Controller

1.

2.

3.

4.

5.

Power down the server (on page 18 ).

Extend the server from the rack (on page 19 ).

Remove the access panel (on page 20 ).

Remove the air baffle (" Remove and install the air baffle " on page 20 ).

Disconnect all cables from the integrated array controller.

Hardware options installation 48

6.

Disconnect the backplane power cable from the system board.

7.

Turn the quarter-turn fasteners and lift the integrated array controller away from the system board.

Installing an integrated HP Smart Array E200i Controller or an HP Smart Array

P400i Controller

1.

Install the integrated array controller.

Hardware options installation 49

2.

Turn the quarter-turn fasteners clockwise.

Upgrading an HP Smart Array E200i Controller cache module and battery pack

Use this procedure to upgrade the standard memory module to an optional memory module with a battery pack.

1.

2.

Power down the server (on page 18 ).

Extend the server from the rack (on page 19 ).

3.

4.

Remove the access panel (on page 20 ).

Remove the air baffle (" Remove and install the air baffle " on page 20 ).

5.

6.

Disconnect the hard drive backplane power cable.

Remove the existing cache module.

Hardware options installation 50

7.

Install the optional cache module.

8.

9.

Remove fan module 1 and 2 (" Remove and install a fan module " on page 22 ).

Remove the HP Smart Array E200i Controller battery tray.

Hardware options installation 51

10.

Install the HP Smart Array E200i Controller battery pack onto the HP Smart Array E200i Controller battery tray.

11.

Install the HP Smart Array E200i Controller battery tray.

12.

Route and connect the battery pack power cable to the HP Smart Array E200i Controller.

Hardware options installation 52

CAUTION: When routing cables, use the cable trough between fan modules 1 and 2. Be sure the cables do not interfere with fan module installation. Be sure to route the cables around the access panel mounting pin bracket so as not to interfere with access panel installation.

13.

14.

15.

16.

17.

18.

Connect the hard drive backplane power cable to the system board.

Install the fan module (" Remove and install a fan module " on page 22 ).

Install the air baffle (" Remove and install the air baffle " on page 20 ).

Install the access panel (on page 20 ).

Slide the server into the rack.

Power up the server (on page 18 ).

Installing an HP Smart Array P400i Controller cache module and battery pack

1.

2.

3.

4.

5.

6.

Power down the server (on page 18 ).

Extend the server from the rack (on page 19 ).

Remove the access panel (on page 20 ).

Remove the air baffle (" Remove and install the air baffle " on page 20 ).

Remove fan modules 1 and 2 (" Remove and install a fan module " on page 22 ).

Remove the HP Smart Array P400i Controller (" Removing an integrated HP Smart Array E200i

Controller or an HP Smart Array P400i Controller " on page 48 ).

Hardware options installation 53

7.

Remove the existing cache module.

8.

Install the optional cache module.

9.

10.

11.

Install the HP Smart Array P400i Controller (" Installing an integrated HP Smart Array E200i

Controller or an HP Smart Array P400i Controller " on page 49 ).

Connect and route the data cables from the HP Smart Array P400i Controller to the hard drive backplane.

Connect the hard drive backplane power cable to the system board.

Hardware options installation 54

CAUTION: When routing cables, use the cable trough between fan modules 1 and 2. Be sure the cables do not interfere with fan module installation. Be sure to route the cables around the access panel mounting pin bracket so as not to interfere with access panel installation.

12.

Remove the HP Smart Array E200i Controller battery tray and retain it for future use.

13.

Connect the power cable from the option kit to the HP Smart Array P400i Controller battery pack.

Hardware options installation 55

14.

Install the HP Smart Array P400i Controller battery pack onto the HP Smart Array P400i Controller battery tray.

15.

Install the HP Smart Array P400i Controller battery tray.

Hardware options installation 56

16.

Connect and route the battery pack power cable to the HP Smart Array P400i Controller cache module.

17.

18.

19.

20.

21.

Install fan modules 1 and 2 (" Remove and install a fan module " on page 22 ).

Install the air baffle (" Remove and install the air baffle " on page 20 ).

Install the access panel (on page 20 ).

Slide the server into the rack.

Power up the server (on page 18 ).

Upgrading the HP Smart Array P400i Controller to support six hard drives

In certain configurations, the server may ship configured with the HP Smart Array P400i Controller and only one data cable installed. To enable support for six hard drives, install an optional Mini-SAS 4i

0.35 m (14 in) cable from the HP Smart Array P400i Controller to the hard drive backplane.

1.

2.

Power down the server (on page 18 ).

Extend the server from the rack (on page 19 ).

3.

4.

Remove the access panel (on page 20 ).

Remove the air baffle (" Remove and install the air baffle " on page 20 ).

5.

6.

Remove fan modules 1 and 2 (" Remove and install a fan module " on page 22 ).

Connect and route the second cable.

CAUTION: When routing cables, use the cable trough between fan modules 1 and 2. Be sure the cables do not interfere with fan module installation. Be sure to route the cables around the access panel mounting pin bracket so as not to interfere with access panel installation.

Hardware options installation 57

CAUTION: When routing cables, always be sure that the cables are not in a position where they can be pinched or crimped.

7.

8.

9.

10.

11.

Install fan modules 1 and 2 (" Remove and install a fan module " on page 22 ).

Install the air baffle (" Remove and install the air baffle " on page 20 ).

Install the access panel (on page 20 ).

Slide the server into the rack.

Power up the server (on page 18 ).

Using a PCI SAS or SATA array controller to support six hard drives

1.

2.

3.

4.

5.

6.

Power down the server (on page 18 ).

Extend the server from the rack (on page 19 ).

Remove the access panel (on page 20 ).

Remove the air baffle (" Remove and install the air baffle " on page 20 ).

Remove fan modules 1 and 2 (" Remove and install a fan module " on page 22 ).

Disconnect all cables from the currently-installed HP Smart Array E200i Controller or HP Smart Array

P400i Controller.

Hardware options installation 58

7.

Disconnect the hard drive backplane power cable from the system board.

8.

9.

10.

Turn the quarter-turn fasteners counter-clockwise and lift the integrated array controller away from the system board.

Connect the hard drive backplane power cable to the system board.

Install and route the cables from the PCI SAS or SATA array controller to the SAS hard drive backplane.

CAUTION: When routing cables, use the cable trough between fan modules 1 and 2. Be sure the cables do not interfere with fan module installation. Be sure to route the cables around the access panel mounting pin bracket so as not to interfere with access panel installation.

CAUTION: When routing cables, always be sure that the cables are not in a position where they can be pinched or crimped.

11.

12.

13.

Install fan modules 1 and 2 (" Remove and install a fan module " on page 22 ).

Install the air baffle (" Remove and install the air baffle " on page 20 ).

Install the access panel (on page 20 ).

Hardware options installation 59

14.

15.

Slide the server into the rack.

Power up the server (on page 18 ).

Using a PCI array controller and the HP Smart Array P400i Controller to support six hard drives

1.

2.

3.

4.

5.

6.

Power down the server (on page 18 ).

Extend the server from the rack (on page 19 ).

Remove the access panel (on page 20 ).

Remove the air baffle (" Remove and install the air baffle " on page 20 ).

Remove fan modules 1 and 2 (" Remove and install a fan module " on page 22 ).

Route and connect the data cables:

Connect the PCI SAS or SATA array controller to the SAS hard drive backplane.

Connect the HP Smart Array P400i Controller to the SAS hard drive backplane.

CAUTION: When routing cables, use the cable trough between fan modules 1 and 2. Be sure the cables do not interfere with fan module installation. Be sure to route the cables around the access panel mounting pin bracket so as not to interfere with access panel installation.

CAUTION: When routing cables, always be sure that the cables are not in a position where they can be pinched or crimped.

7.

8.

9.

10.

11.

Install fan modules 1 and 2 (" Remove and install a fan module " on page 22 ).

Install the air baffle (" Remove and install the air baffle " on page 20 ).

Install the access panel (on page 20 ).

Slide the server into the rack.

Power up the server (on page 18 ).

Hardware options installation 60

Cabling

In this section

Cabling overview................................................................................................................................... 61

Array controller cabling .......................................................................................................................... 61

Multibay backplane cabling .................................................................................................................... 64

Cabling overview

This section provides guidelines that help you make informed decisions about cabling the server and hardware options to optimize performance.

For information on cabling peripheral components, refer to the white paper on high-density deployment at the HP website ( http://www.hp.com/products/servers/platforms ).

CAUTION: When routing cables, always be sure that the cables are not in a position where they can be pinched or crimped.

Array controller cabling

Depending on the primary controller installed, various cabling configurations exist:

HP Smart Array E200i Controller cabling (on page 62 )

HP Smart Array P400i Controller cabling (on page 62 )

PCI Smart Array controller cabling (on page 63 )

Battery pack cabling (on page 63 )

Cabling 61

HP Smart Array E200i Controller cabling

CAUTION: When routing cables, use the cable trough between fan modules 1 and 2. Be sure the cables do not interfere with fan module installation. Be sure to route the cables around the DIMM connectors so as not to interfere with DIMM installation.

HP Smart Array P400i Controller cabling

CAUTION: When routing cables, use the cable trough between fan modules 1 and 2. Be sure the cables do not interfere with fan module installation. Be sure to route the cables around the DIMM connectors so as not to interfere with DIMM installation.

Cabling 62

PCI Smart Array controller cabling

CAUTION: When routing cables, use the cable trough between fan modules 1 and 2. Be sure the cables do not interfere with fan module installation. Be sure to route the cables around the DIMM connectors so as not to interfere with DIMM installation.

IMPORTANT: When using a PCI array controller, be sure to remove the integrated array controller.

Battery pack cabling

HP Smart Array E200i Controller battery pack cabling

Cabling 63

HP Smart Array P400i Controller battery pack cabling

Multibay backplane cabling

Cabling 64

Configuration and utilities

In this section

Configuration tools................................................................................................................................. 65

Management tools.................................................................................................................................. 69

Diagnostic tools ..................................................................................................................................... 72

Remote support and analysis tools............................................................................................................ 73

Keeping the system current ...................................................................................................................... 74

Configuration tools

SmartStart software

SmartStart is a collection of software that optimizes single-server setup, providing a simple and consistent way to deploy server configuration. SmartStart has been tested on many ProLiant server products, resulting in proven, reliable configurations.

SmartStart assists the deployment process by performing a wide range of configuration activities, including:

Configuring hardware using embedded configuration utilities, such as RBSU and ORCA

Preparing the system for installing "off-the-shelf" versions of leading operating system software

Installing optimized server drivers, management agents, and utilities automatically with every assisted installation

Testing server hardware using the Insight Diagnostics Utility (" HP Insight Diagnostics " on page 73 )

Installing software drivers directly from the CD. With systems that have internet connection, the

SmartStart Autorun Menu provides access to a complete list of ProLiant system software.

Enabling access to the Array Configuration Utility (on page 67 ), Array Diagnostic Utility (on page

72 ), and Erase Utility (on page

70

)

SmartStart is included in the HP ProLiant Essentials Foundation Pack. For more information about

SmartStart software, refer to the HP ProLiant Essentials Foundation Pack or the HP website

( http://www.hp.com/servers/smartstart ).

SmartStart Scripting Toolkit

The SmartStart Scripting Toolkit is a server deployment product that delivers an unattended automated installation for high-volume server deployments. The SmartStart Scripting Toolkit is designed to support

ProLiant BL, ML, and DL servers. The toolkit includes a modular set of utilities and important documentation that describes how to apply these new tools to build an automated server deployment process.

Using SmartStart technology, the Scripting Toolkit provides a flexible way to create standard server configuration scripts. These scripts are used to automate many of the manual steps in the server configuration process. This automated server configuration process cuts time from each server deployed, making it possible to scale server deployments to high volumes in a rapid manner.

Configuration and utilities 65

For more information, and to download the SmartStart Scripting Toolkit, refer to the HP website

( http://www.hp.com/servers/sstoolkit ).

Configuration Replication Utility

ConRep is shipped in the SmartStart Scripting Toolkit and is a program that works with RBSU to replicate hardware configuration on ProLiant servers. This utility is run during State 0, Run Hardware Configuration

Utility, when doing a scripted server deployment. ConRep reads the state of the system environment variables to determine the configuration and then writes the results to an editable script file. This file can then be deployed across multiple servers with similar hardware and software components. For more information, refer to the SmartStart Scripting Toolkit User Guide on the HP website

( http://h18004.www1.hp.com/products/servers/management/toolkit/documentation.html

).

HP ROM-Based Setup Utility

RBSU, an embedded configuration utility, performs a wide range of configuration activities that may include:

Configuring system devices and installed options

Displaying system information

Selecting the primary boot controller

Configuring memory options

Language selection

For more information on RBSU, refer to the HP ROM-Based Setup Utility User Guide on the Documentation

CD or the HP website ( http://www.hp.com/servers/smartstart ).

Using RBSU

The first time you power up the server, the system prompts you to enter RBSU and select a language.

Default configuration settings are made at this time and can be changed later. Most of the features in

RBSU are not required to set up the server.

To navigate RBSU, use the following keys:

To access RBSU, press the F9 key during power up when prompted in the upper right corner of the screen.

To navigate the menu system, use the arrow keys.

To make selections, press the Enter key.

IMPORTANT: RBSU automatically saves settings when you press the Enter key. The utility does not prompt you for confirmation of settings before you exit the utility. To change a selected setting, you must select a different setting and press the Enter key.

Auto-configuration process

The auto-configuration process automatically runs when you boot the server for the first time. During the power-up sequence, the system ROM automatically configures the entire system without needing any intervention. During this process, the ORCA utility, in most cases, automatically configures the array to a default setting based on the number of drives connected to the server.

NOTE: The server may not support all the following examples.

NOTE: If the boot drive is not empty or has been written to in the past, ORCA does not automatically configure the array. You must run ORCA to configure the array settings.

Configuration and utilities 66

Drives installed Drives used RAID level

3, 4, 5, or 6

More than 6

3, 4, 5, or 6

0

RAID 5

None

To change any ORCA default settings and override the auto-configuration process, press the F8 key when prompted.

By default, the auto-configuration process configures the system for the English language. To change any default settings in the auto-configuration process (such as the settings for language, operating system, and primary boot controller), execute RBSU by pressing the F9 key when prompted. After the settings are selected, exit RBSU and allow the server to reboot automatically.

For more information, refer to the HP ROM-Based Setup Utility User Guide on the Documentation CD or the HP website ( http://www.hp.com/servers/smartstart ).

Boot options

After the auto-configuration process completes, or after the server reboots upon exit from RBSU, the POST sequence runs, and then the boot option screen is displayed. This screen is visible for several seconds before the system attempts to boot from a diskette, CD, or hard drive. During this time, the menu on the screen allows you to install an operating system or make changes to the server configuration in RBSU.

BIOS Serial Console

BIOS Serial Console allows you to configure the serial port to view POST error messages and run RBSU remotely through a serial connection to the server COM port. The server that you are remotely configuring does not require a keyboard and mouse.

For more information about BIOS Serial Console, refer to the BIOS Serial Console User Guide on the

Documentation CD or the HP website ( http://www.hp.com/servers/smartstart ).

Array Configuration Utility

ACU is a browser-based utility with the following features:

Runs as a local application or remote service

Supports online array capacity expansion, logical drive extension, assignment of online spares, and

RAID or stripe size migration

Suggests the optimum configuration for an unconfigured system

Provides different operating modes, enabling faster configuration or greater control over the configuration options

Remains available any time that the server is on

Displays on-screen tips for individual steps of a configuration procedure

For optimum performance, the minimum display settings are 800 × 600 resolution and 256 colors.

Servers running Microsoft® operating systems require Internet Explorer 5.5 (with Service Pack 1) or later.

For Linux servers, refer to the README.TXT file for additional browser and support information.

For more information, refer to the Configuring Arrays on HP Smart Array Controllers Reference Guide on the Documentation CD or the HP website ( http://www.hp.com

).

Configuration and utilities 67

Option ROM Configuration for Arrays

Before installing an operating system, you can use the ORCA utility to create the first logical drive, assign

RAID levels, and establish online spare configurations.

The utility also provides support for the following functions:

Reconfiguring one or more logical drives

Viewing the current logical drive configuration

Deleting a logical drive configuration

Setting the controller to be the boot controller

If you do not use the utility, ORCA will default to the standard configuration.

For more information regarding array controller configuration, refer to the controller user guide.

For more information regarding the default configurations that ORCA uses, refer to the HP ROM-Based

Setup Utility User Guide on the Documentation CD.

HP ProLiant Essentials Rapid Deployment Pack

NOTE: To deploy servers in an existing server blade enclosure, always use the most recent version of RDP available at the HP website ( http://www.hp.com/servers/rdp ).

The RDP software is the preferred method for rapid, high-volume server deployments. The RDP software integrates two powerful products: Altiris Deployment Solution and the HP ProLiant Integration Module.

The intuitive graphical user interface of the Altiris Deployment Solution console provides simplified pointand-click and drag-and-drop operations that enable you to deploy target servers, including server blades, remotely. It enables you to perform imaging or scripting functions and maintain software images.

For more information about the RDP, refer to the HP ProLiant Essentials Rapid Deployment Pack CD or refer to the HP website ( http://www.hp.com/servers/rdp ).

Re-entering the server serial number and product ID

After you replace the system board, you must re-enter the server serial number and the product ID.

1.

During the server startup sequence, press the F9 key to access RBSU.

2.

3.

Select the System Options menu.

Select Serial Number. The following warning is displayed:

WARNING! WARNING! WARNING! The serial number is loaded into the system during the manufacturing process and should NOT be modified. This option

4.

5.

6.

7.

8.

9.

10.

should only be used by qualified service personnel. This value should always match the serial number sticker located on the chassis.

Press the Enter key to clear the warning.

Enter the serial number and press the Enter key.

Select Product ID.

Enter the product ID and press the Enter key.

Press the Esc key to close the menu.

Press the Esc key to exit RBSU.

Press the F10 key to confirm exiting RBSU. The server will automatically reboot.

Configuration and utilities 68

Management tools

Automatic Server Recovery

ASR is a feature that causes the system to restart when a catastrophic operating system error occurs, such as a blue screen, ABEND, or panic. A system fail-safe timer, the ASR timer, starts when the System

Management driver, also known as the Health Driver, is loaded. When the operating system is functioning properly, the system periodically resets the timer. However, when the operating system fails, the timer expires and restarts the server.

ASR increases server availability by restarting the server within a specified time after a system hang or shutdown. At the same time, the HP SIM console notifies you by sending a message to a designated pager number that ASR has restarted the system. You can disable ASR from the HP SIM console or through RBSU.

ROMPaq utility

Flash ROM enables you to upgrade the firmware (BIOS) with system or option ROMPaq utilities. To upgrade the BIOS, insert a ROMPaq diskette into the diskette drive and boot the system.

The ROMPaq utility checks the system and provides a choice (if more than one exists) of available ROM revisions. This procedure is the same for both system and option ROMPaq utilities.

For more information about the ROMPaq utility, refer to the HP website

( http://www.hp.com/servers/manage ).

System Online ROM flash component utility

The Online ROM Flash Component Utility enables system administrators to efficiently upgrade system or controller ROM images across a wide range of servers and array controllers. This tool has the following features:

Works offline and online

Supports Microsoft® Windows® 2000, Windows Server™ 2003, and Linux operating systems

IMPORTANT: This utility supports operating systems that may not be supported by the server. For operating systems supported by the server, refer to the HP website ( http://www.hp.com/go/supportos ).

Integrates with other software maintenance, deployment, and operating system tools

Automatically checks for hardware, firmware, and operating system dependencies, and installs only the correct ROM upgrades required by each target server

To download the tool and for more information, refer to the HP website

( http://h18000.www1.hp.com/support/files/index.html

).

Integrated Lights-Out 2 technology

The iLO 2 subsystem is a standard component of selected ProLiant servers that provides server health and remote server manageability. The iLO 2 subsystem includes an intelligent microprocessor, secure memory, and a dedicated network interface. This design makes iLO 2 independent of the host server and its operating system. The iLO 2 subsystem provides remote access to any authorized network client, sends alerts, and provides other server management functions.

Using iLO 2, you can:

Remotely power up, power down, or reboot the host server.

Send alerts from iLO 2 regardless of the state of the host server.

Configuration and utilities 69

Access advanced troubleshooting features through the iLO 2 interface.

Diagnose iLO 2 using HP SIM through a web browser and SNMP alerting.

For more information about iLO 2 features, refer to the iLO 2 documentation on the Documentation CD or on the HP website ( http://www.hp.com/servers/lights-out ).

Erase Utility

CAUTION: Perform a backup before running the System Erase Utility. The utility sets the system to its original factory state, deletes the current hardware configuration information, including array setup and disk partitioning, and erases all connected hard drives completely. Refer to the instructions for using this utility.

Run the Erase Utility if you need to erase the system for the following reasons:

You want to install a new operating system on a server with an existing operating system.

You want to change the operating system selection.

You encounter a failure-causing error during the SmartStart installation.

You encounter an error when completing the steps of a factory-installed operating system installation.

The Erase Utility can be accessed from the Software and Drivers Download website

( http://www.hp.com/go/support ) or the Maintenance Utilities menu of the SmartStart CD

(" SmartStart software " on page 65 ).

Management Agents

Management Agents provide the information to enable fault, performance, and configuration management. The agents allow easy manageability of the server through HP SIM software, and thirdparty SNMP management platforms. Management Agents are installed with every SmartStart assisted installation or can be installed through the HP PSP. The Systems Management homepage provides status and direct access to in-depth subsystem information by accessing data reported through the Management

Agents. For additional information, refer to the Management CD in the HP ProLiant Essentials Foundation

Pack or the HP website ( http://www.hp.com/servers/manage ).

HP Systems Insight Manager

HP SIM is a web-based application that allows system administrators to accomplish normal administrative tasks from any remote location, using a web browser. HP SIM provides device management capabilities that consolidate and integrate management data from HP and third-party devices.

IMPORTANT: You must install and use HP SIM to benefit from the Pre-Failure Warranty for processors,

SAS and SCSI hard drives, and memory modules.

For additional information, refer to the Management CD in the HP ProLiant Essentials Foundation Pack or the HP SIM website ( http://www.hp.com/go/hpsim ).

Redundant ROM support

The server enables you to upgrade or configure the ROM safely with redundant ROM support. The server has a 4-MB ROM that acts as two, separate 2-MB ROMs. In the standard implementation, one side of the

ROM contains the current ROM program version, while the other side of the ROM contains a backup version.

NOTE: The server ships with the same version programmed on each side of the ROM.

Configuration and utilities 70

Safety and security benefits

When you flash the system ROM, ROMPaq writes over the backup ROM and saves the current ROM as a backup, enabling you to switch easily to the alternate ROM version if the new ROM becomes corrupted for any reason. This feature protects the existing ROM version, even if you experience a power failure while flashing the ROM.

Access to redundant ROM settings

To access the redundant ROM through RBSU:

1.

Access RBSU by pressing the F9 key during powerup when the prompt is displayed in the upper right corner of the screen.

2.

3.

4.

5.

6.

Select Advanced Options.

Select Redundant ROM Selection.

Select the ROM version.

Press the Enter key.

Press the Esc key to exit the current menu or press the F10 key to exit RBSU. The server restarts automatically.

To access the redundant ROM manually:

1.

Power down the server (on page 18 ).

2.

3.

4.

5.

Remove the access panel (on page 20 ).

Set positions 1, 5, and 6 of the system maintenance switch to On.

Install the access panel (on page 20

Power up the server (on page 18 ).

).

6.

7.

Wait for the server to emit two beeps.

Repeat steps 1 and 2.

8.

9.

Set positions 1, 5, and 6 of the system maintenance switch to Off.

Repeat steps 4 and 5.

When the server boots, the system identifies whether the current ROM bank is corrupt. If a corrupt ROM is detected, the system boots from the backup ROM and alerts you through POST or IML that the ROM bank is corrupt.

If both the current and backup versions of the ROM are corrupt, the server automatically enters ROMPaq disaster recovery mode.

USB support

HP provides both standard USB support and legacy USB support. Standard support is provided by the operating system through the appropriate USB device drivers. HP provides support for USB devices prior to the operating system loading through legacy USB support, which is enabled by default in the system

ROM. HP hardware supports USB version 2.0.

Legacy USB support provides USB functionality in environments where USB support is normally not available. Specifically, HP provides legacy USB functionality at:

POST

RBSU

Diagnostics

DOS

Environments which do not support USB natively

Configuration and utilities 71

For more information on ProLiant USB support, refer to the HP website

( http://www.compaq.com/products/servers/platforms/usb-support.html

).

Changing the USB version support

The factory default setting for this server is USB version 1.1. After the OS has loaded, this setting can be changed to USB version 2.0 using the following steps:

1.

2.

Access RBSU by pressing F9 during power up.

Select System Options.

3.

4.

5.

6.

7.

Select USB External Port Capability.

Press Enter to display USB 1.1 and USB 2.0 selections.

Arrow down to highlight USB 2.0.

Press Enter.

Press F10 to save the change and exit RBSU.

Internal USB functionality

An internal USB connector is available for use with USB drive keys only. This solution provides for use of a permanent boot drive from a USB drive key installed in the internal connector, avoiding issues of clearance on the front of the rack and physical access to secure data.

For additional security, the external USB connectors can be disabled through RBSU. Disabling external

USB in RBSU disables the front USB connector and both rear USB connectors.

Diagnostic tools

Survey Utility

Survey Utility, a feature within HP Insight Diagnostics (on page 73 ), gathers critical hardware and

software information on ProLiant servers.

This utility supports operating systems that may not be supported by the server. For operating systems supported by the server, refer to the HP website ( http://www.hp.com/go/supportos ).

If a significant change occurs between data-gathering intervals, the Survey Utility marks the previous information and overwrites the Survey text files to reflect the latest changes in the configuration.

Survey Utility is installed with every SmartStart-assisted installation or can be installed through the HP PSP

(" ProLiant Support Packs " on page 74 ).

NOTE: The current version of SmartStart provides the memory spare part numbers for the server. To download the latest version, see the HP website ( http://www.hp.com/go/ssdownloads ).

Array Diagnostic Utility

ADU is a tool that collects information about array controllers and generates a list of detected problems.

ADU can be accessed from the SmartStart CD (" SmartStart software " on page 65 ) or downloaded from

the HP website ( http://www.hp.com

).

Configuration and utilities 72

HP Insight Diagnostics

HP Insight Diagnostics is a proactive server management tool, available in both offline and online versions, that provides diagnostics and troubleshooting capabilities to assist IT administrators who verify server installations, troubleshoot problems, and perform repair validation.

HP Insight Diagnostics Offline Edition performs various in-depth system and component testing while the

OS is not running. To run this utility, launch the SmartStart CD.

HP Insight Diagnostics Online Edition is a web-based application that captures system configuration and other related data needed for effective server management. Available in Microsoft® Windows® and

Linux versions, the utility helps to ensure proper system operation.

For more information or to download the utility, refer to the HP website

( http://www.hp.com/servers/diags ).

Integrated Management Log

The IML records hundreds of events and stores them in an easy-to-view form. The IML timestamps each event with 1-minute granularity.

You can view recorded events in the IML in several ways, including the following:

From within HP SIM (" HP Systems Insight Manager " on page 70 )

From within Survey Utility (on page 72 )

From within operating system-specific IML viewers

For NetWare: IML Viewer

For Windows®: IML Viewer

For Linux: IML Viewer Application

From within the iLO 2 user interface

From within HP Insight Diagnostics (on page 73 )

For more information, refer to the Management CD in the HP ProLiant Essentials Foundation Pack.

Remote support and analysis tools

HP Instant Support Enterprise Edition

ISEE is a proactive remote monitoring and diagnostic tool to help manage your systems and devices, a feature of HP support. ISEE provides continuous hardware event monitoring and automated notification to identify and prevent potential critical problems. Through remote diagnostic scripts and vital system configuration information collected about your systems, ISEE enables fast restoration of your systems.

Install ISEE on your systems to help mitigate risk and prevent potential critical problems.

For more information on ISEE, refer to the HP website

( http://www.hp.com/hps/hardware/hw_enterprise.html

).

To download HP ISEE, visit the HP website ( http://www.hp.com/hps/hardware/hw_downloads.html

).

For installation information, refer to the HP ISEE Client Installation and Upgrade Guide

( ftp://ftp.hp.com/pub/services/hardware/info/isee_client.pdf

).

Configuration and utilities 73

Web-Based Enterprise Service

WEBES enables administrators to manage hardware events proactively, either locally or online. The service provides real-time multiple event analysis, crash analysis, and notification, locally through SMTP and remotely through ISEE for OpenVMS, Tru64, and Microsoft® Windows® operating system binary error logs.

For more information, refer to the HP website ( http://h18000.www1.hp.com/support/svctools/ ).

Open Services Event Manager

OSEM is a standalone tool that performs real-time reactive and proactive service event filtering, analysis, and notification. The tool gathers event data from SNMP traps or information provided over an HTTP interface and notifies an administrator or HP through SMTP and ISEE.

For more information, refer to the HP website ( http://h18000.www1.hp.com/support/svctools/ ).

Keeping the system current

Drivers

The server includes new hardware that may not have driver support on all operating system installation media.

If you are installing a SmartStart-supported operating system, use the SmartStart software (on page 65 )

and its Assisted Path feature to install the operating system and latest driver support.

NOTE: If you are installing drivers from the SmartStart CD or the Software Maintenance CD, refer to the

SmartStart website ( http://www.hp.com/servers/smartstart ) to be sure that you are using the latest version of SmartStart. For more information, refer to the documentation provided with the SmartStart CD.

If you do not use the SmartStart CD to install an operating system, drivers for some of the new hardware are required. These drivers, as well as other option drivers, ROM images, and value-add software can be downloaded from the HP website ( http://www.hp.com/support ).

IMPORTANT: Always perform a backup before installing or updating device drivers.

Resource Paqs

Resource Paqs are operating system-specific packages of tools, utilities, and information for HP servers running certain Microsoft® or Novell operating systems. The Resource Paqs include utilities to monitor performance, software drivers, customer support information, and white papers on the latest server integration information. Refer to the Enterprise Partnerships website

( http://h18000.www1.hp.com/partners ), select Microsoft or Novell, depending on the operating system, and follow the link to the appropriate Resource Paq.

ProLiant Support Packs

PSPs represent operating system-specific bundles of ProLiant optimized drivers, utilities, and management agents. Refer to the PSP website

( http://h18000.www1.hp.com/products/servers/management/psp.html

).

Operating system version support

Refer to the operating system support matrix ( http://www.hp.com/go/supportos ).

Configuration and utilities 74

System Online ROM flash component utility

The Online ROM Flash Component Utility enables system administrators to efficiently upgrade system or controller ROM images across a wide range of servers and array controllers. This tool has the following features:

Works offline and online

Supports Microsoft® Windows NT®, Windows® 2000, Windows Server™ 2003, Novell Netware, and Linux operating systems

IMPORTANT: This utility supports operating systems that may not be supported by the server. For operating systems supported by the server, refer to the HP website ( http://www.hp.com/go/supportos ).

Integrates with other software maintenance, deployment, and operating system tools

Automatically checks for hardware, firmware, and operating system dependencies, and installs only the correct ROM upgrades required by each target server

To download the tool and for more information, refer to the HP website

( http://h18000.www1.hp.com/support/files/index.html

).

Change control and proactive notification

HP offers Change Control and Proactive Notification to notify customers 30 to 60 days in advance of upcoming hardware and software changes on HP commercial products.

For more information, refer to the HP website

( http://h18023.www1.hp.com/solutions/pcsolutions/pcn.html

).

Care Pack

HP Care Pack Services offer upgraded service levels to extend and expand standard product warranty with easy-to-buy, easy-to-use support packages that help you make the most of your server investments.

Refer to the Care Pack website ( http://www.hp.com/hps/carepack/servers/cp_proliant.html

).

Configuration and utilities 75

Troubleshooting

In this section

Troubleshooting resources ....................................................................................................................... 76

Pre-diagnostic steps ................................................................................................................................ 76

Loose connections .................................................................................................................................. 79

Service notifications................................................................................................................................ 79

Troubleshooting flowcharts ...................................................................................................................... 80

POST error messages and beep codes...................................................................................................... 91

Troubleshooting resources

The HP ProLiant Servers Troubleshooting Guide provides simple procedures for resolving common problems as well as a comprehensive course of action for fault isolation and identification, error message interpretation, issue resolution, and software maintenance.

To obtain the guide, refer to any of the following sources and then select the HP ProLiant Servers

Troubleshooting Guide:

The server-specific Documentation CD

The Business Support Center on the HP website ( http://www.hp.com/support ). Navigate to the server technical support page. Under self-help resources, select ProLiant Troubleshooting

Guide.

The Technical Documentation website ( http://www.docs.hp.com

). Select Enterprise Servers,

Workstations and Systems Hardware, and then the appropriate server.

Pre-diagnostic steps

WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary

information in the server documentation before removing, replacing, reseating, or

modifying system components.

IMPORTANT: This guide provides information for multiple servers. Some information may not apply to the server you are troubleshooting. Refer to the server documentation for information on procedures, hardware options, software tools, and operating systems supported by the server.

1.

2.

Review the important safety information (on page 76 ).

Gather symptom information (on page 78 ).

3.

4.

Prepare the server for diagnosis (on page 79 ).

Use the Start diagnosis flowchart (on page 80 ) to begin the diagnostic process.

Important safety information

Familiarize yourself with the safety information in the following sections before troubleshooting the server.

Troubleshooting 76

Important safety information

Before servicing this product, read the Important Safety Information document provided with the server.

Symbols on equipment

The following symbols may be placed on equipment to indicate the presence of potentially hazardous conditions.

This symbol indicates the presence of hazardous energy circuits or electric shock hazards. Refer all servicing to qualified personnel.

WARNING: To reduce the risk of injury from electric shock hazards, do not open this enclosure. Refer all maintenance, upgrades, and servicing to qualified personnel.

This symbol indicates the presence of electric shock hazards. The area contains no user or field serviceable parts. Do not open for any reason.

WARNING: To reduce the risk of injury from electric shock hazards, do not open this enclosure.

This symbol on an RJ-45 receptacle indicates a network interface connection.

WARNING: To reduce the risk of electric shock, fire, or damage to the equipment, do not plug telephone or telecommunications connectors into this receptacle.

This symbol indicates the presence of a hot surface or hot component. If this surface is contacted, the potential for injury exists.

WARNING: To reduce the risk of injury from a hot component, allow the surface to cool before touching.

14.06 - 17.92 kg

31.00 - 39.50 lb

This symbol indicates that the component exceeds the recommended weight for one individual to handle safely.

WARNING: To reduce the risk of personal injury or damage to the equipment, observe local occupational health and safety requirements and guidelines for manual material handling.

These symbols, on power supplies or systems, indicate that the equipment is supplied by multiple sources of power.

WARNING: To reduce the risk of injury from electric shock, remove all power cords to completely disconnect power from the system.

Warnings and cautions

WARNING: Only authorized technicians trained by HP should attempt to repair this

equipment. All troubleshooting and repair procedures are detailed to allow only subassembly/module-level repair. Because of the complexity of the individual boards and subassemblies, no one should attempt to make repairs at the component level or to make modifications to any printed wiring board. Improper repairs can create a safety

hazard.

Troubleshooting 77

WARNING: To reduce the risk of personal injury or damage to the equipment, be sure

that:

The leveling feet are extended to the floor.

The full weight of the rack rests on the leveling feet.

The stabilizing feet are attached to the rack if it is a single-rack installation.

The racks are coupled together in multiple-rack installations.

Only one component is extended at a time. A rack may become unstable if more than

one component is extended for any reason.

WARNING: To reduce the risk of electric shock or damage to the equipment:

Do not disable the power cord grounding plug. The grounding plug is an important

safety feature.

Plug the power cord into a grounded (earthed) electrical outlet that is easily

accessible at all times.

Unplug the power cord from the power supply to disconnect power to the equipment.

Do not route the power cord where it can be walked on or pinched by items placed

against it. Pay particular attention to the plug, electrical outlet, and the point where

the cord extends from the server.

14.06 - 17.92 kg

31.00 - 39.50 lb

WARNING: To reduce the risk of personal injury or damage to the equipment:

• Observe local occupation health and safety requirements and guidelines for manual handling.

• Obtain adequate assistance to lift and stabilize the chassis during installation or removal.

• The server is unstable when not fastened to the rails.

• When mounting the server in a rack, remove the power supplies and any other removable module to reduce the overall weight of the product.

CAUTION: To properly ventilate the system, you must provide at least 7.6 cm (3.0 in) of clearance at the front and back of the server.

CAUTION: The server is designed to be electrically grounded (earthed). To ensure proper operation, plug the AC power cord into a properly grounded AC outlet only.

Symptom information

Before troubleshooting a server problem, collect the following information:

What events preceded the failure? After which steps does the problem occur?

What has been changed since the time the server was working?

Did you recently add or remove hardware or software? If so, did you remember to change the appropriate settings in the server setup utility, if necessary?

How long has the server exhibited problem symptoms?

If the problem occurs randomly, what is the duration or frequency?

To answer these questions, the following information may be useful:

Run HP Insight Diagnostics (on page 73 ) and use the survey page to view the current configuration

or to compare it to previous configurations.

Refer to your hardware and software records for information.

Refer to server LEDs and their statuses.

Troubleshooting 78

Prepare the server for diagnosis

1.

2.

3.

4.

5.

6.

Be sure the server is in the proper operating environment with adequate power, air conditioning, and humidity control. Refer to the server documentation for required environmental conditions.

Record any error messages displayed by the system.

Remove all diskettes and CDs from the media drives.

Power down the server and peripheral devices if you will be diagnosing the server offline. Always perform an orderly shutdown, if possible. This means you must:

a.

Exit any applications.

b.

Exit the operating system.

c.

Power down the server (on page 18 ).

Disconnect any peripheral devices not required for testing (any devices not necessary to power up the server). Do not disconnect the printer if you want to use it to print error messages.

Collect all tools and utilities, such as a Torx screwdriver, loopback adapters, ESD wrist strap, and software utilities, necessary to troubleshoot the problem.

You must have the appropriate Health Drivers and Management Agents installed on the server.

NOTE: To verify the server configuration, connect to the System Management homepage and select

Version Control Agent. The VCA gives you a list of names and versions of all installed HP drivers,

Management Agents, and utilities, and whether they are up to date.

HP recommends you have access to the SmartStart CD for value-added software and drivers required during the troubleshooting process.

HP recommends you have access to the server documentation for server-specific information.

Loose connections

Action:

Be sure all power cords are securely connected.

Be sure all cables are properly aligned and securely connected for all external and internal components.

Remove and check all data and power cables for damage. Be sure no cables have bent pins or damaged connectors.

If a fixed cable tray is available for the server, be sure the cords and cables connected to the server are correctly routed through the tray.

Be sure each device is properly seated.

If a device has latches, be sure they are completely closed and locked.

Check any interlock or interconnect LEDs that may indicate a component is not connected properly.

If problems continue to occur, remove and reinstall each device, checking the connectors and sockets for bent pins or other damage.

Service notifications

To view the latest service notifications, refer to the HP website ( http://www.hp.com/go/bizsupport ).

Select the appropriate server model, and then click the Troubleshoot a Problem link on the product page.

Troubleshooting 79

Troubleshooting flowcharts

To effectively troubleshoot a problem, HP recommends that you start with the first flowchart in this section,

"Start diagnosis flowchart (on page 80 )," and follow the appropriate diagnostic path. If the other

flowcharts do not provide a troubleshooting solution, follow the diagnostic steps in "General diagnosis

flowchart (on page 81 )." The General diagnosis flowchart is a generic troubleshooting process to be used

when the problem is not server-specific or is not easily categorized into the other flowcharts.

The available flowcharts include:

Start diagnosis flowchart (on page 80 )

General diagnosis flowchart (on page 81 )

Server power-on problems flowchart (on page 83 )

POST problems flowchart (on page 86 )

OS boot problems flowchart (on page 87 )

Server fault indications flowchart (on page 89 )

Start diagnosis flowchart

Use the following flowchart to start the diagnostic process.

3

4

5

1

2

"General diagnosis flowchart (on page 81 )"

"Power-on problems flowchart (" Server power-on problems flowchart " on page 83

)"

"POST problems flowchart (on page 86 )"

"OS boot problems flowchart (on page 87 )"

"Server fault indications flowchart (on page 89 )"

Troubleshooting 80

General diagnosis flowchart

The General diagnosis flowchart provides a generic approach to troubleshooting. If you are unsure of the problem, or if the other flowcharts do not fix the problem, use the following flowchart.

1

2

3

"Symptom information (on page 78 )"

"Loose connections (on page 79 )"

"Service notifications (on page 79 )"

Troubleshooting 81

5

6

7

4

8

9

The most recent version of a particular server or option firmware is available on the following websites:

HP Support website ( http://www.hp.com/support )

• HP ROM-BIOS/Firmware Updates website

( http://h18023.www1.hp.com/support/files/server/us/romflash.ht

ml )

"General memory problems are occurring" in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the HP website ( http://www.hp.com/support )

Server maintenance and service guide, located on the Documentation

CD or the HP website ( http://www.hp.com/products/servers/platforms )

Server maintenance and service guide, located on the

Documentation CD or the HP website

( http://www.hp.com/products/servers/platforms )

• "Hardware problems" in the HP ProLiant Servers Troubleshooting

Guide located on the Documentation CD or on the HP website

( http://www.hp.com/support )

"Server information you need" in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the

HP website ( http://www.hp.com/support )

• "Operating system information you need" in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the

HP website ( http://www.hp.com/support )

"HP contact information (on page 102

)"

Troubleshooting 82

Server power-on problems flowchart

Symptoms:

The server does not power on.

The system power LED is off or amber.

The external health LED is red or amber.

Troubleshooting 83

The internal health LED is red or amber.

NOTE: For the location of server LEDs and information on their statuses, refer to the server documentation.

Possible causes:

Improperly seated or faulty power supply

Loose or faulty power cord

Power source problem

Power on circuit problem

Improperly seated component or interlock problem

Faulty internal component

3

4

5

1

2

6

7

8

"Component identification (on page 7 )"

"HP Insight Diagnostics (on page 73 )" or in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the HP website ( http://www.hp.com/support )

"Loose connections (on page 79 )"

Server maintenance and service guide, located on the Documentation

CD, or the HP website ( http://www.hp.com/products/servers/platforms )

"Integrated Management Log" or in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the HP website ( http://www.hp.com/support )

"Power source problems" in the HP ProLiant Servers Troubleshooting

Guide located on the Documentation CD or on the HP website

( http://www.hp.com/support )

• "Power supply problems" in the HP ProLiant Servers Troubleshooting

Guide located on the Documentation CD or on the HP website

( http://www.hp.com/support )

Server maintenance and service guide, located on the

Documentation CD, or the HP website

( http://www.hp.com/products/servers/platforms )

"System open circuits and short circuits" in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the HP website ( http://www.hp.com/support )

Troubleshooting 84

Troubleshooting 85

POST problems flowchart

Symptoms:

Server does not complete POST

NOTE: The server has completed POST when the system attempts to access the boot device.

Server completes POST with errors

Possible problems:

Improperly seated or faulty internal component

Faulty KVM device

Faulty video device

1

2

5

6

3

4

7

8

9

10

"POST error messages and beep codes (on page 91 )"

"Video problems" in the HP ProLiant Servers Troubleshooting Guide located on the Documentation CD or on the HP website

( http://www.hp.com/support )

KVM or iLO 2 documentation

"Loose connections (on page 79 )"

"Symptom information (on page 78 )"

Server maintenance and service guide, located on the Documentation

CD or the HP website ( http://www.hp.com/products/servers/platforms )

"Port 85 and iLO messages" in the HP ProLiant Servers Troubleshooting

Guide located on the Documentation CD or on the HP website

( http://www.hp.com/support )

"General memory problems are occurring" in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the HP website ( http://www.hp.com/support )

"Hardware problems" in the HP ProLiant Servers Troubleshooting

Guide located on the Documentation CD or on the HP website

( http://www.hp.com/support )

• Server maintenance and service guide, located on the

Documentation CD or the HP website

( http://www.hp.com/products/servers/platforms )

• "Server information you need" in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the

HP website ( http://www.hp.com/support )

• "Operating system information you need" in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the

HP website ( http://www.hp.com/support )

Troubleshooting 86

OS boot problems flowchart

Symptoms:

Server does not boot a previously installed operating system

Server does not boot SmartStart

Possible causes:

Corrupted operating system

Hard drive subsystem problem

Incorrect boot order setting in RBSU

Troubleshooting 87

1

2

3

4

5

6

7

8

9

HP ROM-Based Setup Utility User Guide

( http://www.hp.com/servers/smartstart )

"POST problems flowchart (on page 86 )"

"Hard drive problems" in the HP ProLiant Servers Troubleshooting

Guide located on the Documentation CD or on the HP website

( http://www.hp.com/support )

• Controller documentation

"HP Insight Diagnostics (on page 73 )" or in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the HP website ( http://www.hp.com/support )

• "CD-ROM and DVD drive problems" in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the

HP website ( http://www.hp.com/support )

Controller documentation

"Loose connections (on page 79 )"

"General memory problems are occurring" in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the HP website ( http://www.hp.com/support )

• "Operating system problems" in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the

HP website ( http://www.hp.com/support )

"HP contact information (on page 102

)"

"Hardware problems" in the HP ProLiant Servers Troubleshooting

Guide located on the Documentation CD or on the HP website

( http://www.hp.com/support )

• Server maintenance and service guide, located on the

Documentation CD or the HP website

( http://www.hp.com/products/servers/platforms )

"General diagnosis flowchart (on page 81 )"

Troubleshooting 88

Server fault indications flowchart

Symptoms:

Server boots, but a fault event is reported by Insight Management Agents (on page 70 )

Server boots, but the internal health LED, external health LED, or component health LED is red or amber

NOTE: For the location of server LEDs and information on their statuses, refer to the server documentation.

Troubleshooting 89

3

4

5

6

Possible causes:

Improperly seated or faulty internal or external component

Unsupported component installed

Redundancy failure

System overtemperature condition

1

2

7

8

"Management agents (on page 70 )" or in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the HP website ( http://www.hp.com/support )

• "Integrated Management Log" or in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the

HP website ( http://www.hp.com/support )

"Event list error messages" in the HP ProLiant Servers Troubleshooting

Guide located on the Documentation CD or on the HP website

( http://www.hp.com/support )

"Component identification (on page 7 )"

System Management Homepage ( https://localhost:2381 )

"Power-on problems flowchart (" Server power-on problems flowchart " on page 83

)"

"Smart Array SCSI Diagnosis feature" in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the

HP website ( http://www.hp.com/support )

• Server maintenance and service guide, located on the

Documentation CD or the HP website

( http://www.hp.com/products/servers/platforms )

"HP contact information (on page 102

)"

"HP Insight Diagnostics (on page 73 )" or in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the HP website ( http://www.hp.com/support )

• "Hardware problems" in the HP ProLiant Servers Troubleshooting

Guide located on the Documentation CD or on the HP website

( http://www.hp.com/support )

Server maintenance and service guide, located on the

Documentation CD or the HP website

( http://www.hp.com/products/servers/platforms )

Troubleshooting 90

POST error messages and beep codes

For a complete listing of error messages, refer to the "POST error messages" in the HP ProLiant Servers

Troubleshooting Guide located on the Documentation CD or on the HP website

( http://www.hp.com/support ).

WARNING: To avoid potential problems, ALWAYS read the warnings and cautionary

information in the server documentation before removing, replacing, reseating, or

modifying system components.

Troubleshooting 91

Battery replacement

If the server no longer automatically displays the correct date and time, you may need to replace the battery that provides power to the real-time clock. Under normal use, battery life is 5 to 10 years.

WARNING: The computer contains an internal lithium manganese dioxide, a vanadium

pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack

is not properly handled. To reduce the risk of personal injury:

Do not attempt to recharge the battery.

Do not expose the battery to temperatures higher than 60°C (140°F).

Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or

water.

Replace only with the spare designated for this product.

To remove the component:

1.

Power down the server (on page 18 ).

2.

Extend or remove the server from the rack (" Extend the server from the rack " on page 19 ).

3.

Remove the access panel (on page 20 ).

4.

Remove the PCI riser board assembly (on page 21 ).

5.

Locate the battery on the system board.

6.

Remove the battery.

IMPORTANT: Replacing the system board battery resets the system ROM to its default configuration. After replacing the battery, reconfigure the system through RBSU.

To replace the component, reverse the removal procedure.

For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider.

Battery replacement 92

Regulatory compliance notices

In this section

Regulatory compliance identification numbers ........................................................................................... 93

Federal Communications Commission notice ............................................................................................. 93

Declaration of conformity for products marked with the FCC logo, United States only..................................... 94

Modifications......................................................................................................................................... 95

Cables .................................................................................................................................................. 95

Canadian notice (Avis Canadien) ............................................................................................................ 95

European Union regulatory notice ............................................................................................................ 95

Disposal of waste equipment by users in private households in the European Union....................................... 96

Japanese notice ..................................................................................................................................... 96

BSMI notice ........................................................................................................................................... 96

Korean notice ........................................................................................................................................ 97

Laser compliance ................................................................................................................................... 97

Battery replacement notice ...................................................................................................................... 97

Taiwan battery recycling notice ............................................................................................................... 98

Power cord statement for Japan ............................................................................................................... 98

Regulatory compliance identification numbers

For the purpose of regulatory compliance certifications and identification, this product has been assigned a unique regulatory model number. The regulatory model number can be found on the product nameplate label, along with all required approval markings and information. When requesting compliance information for this product, always refer to this regulatory model number. The regulatory model number is not the marketing name or model number of the product.

Federal Communications Commission notice

Part 15 of the Federal Communications Commission (FCC) Rules and Regulations has established Radio

Frequency (RF) emission limits to provide an interference-free radio frequency spectrum. Many electronic devices, including computers, generate RF energy incidental to their intended function and are, therefore, covered by these rules. These rules place computers and related peripheral devices into two classes, A and B, depending upon their intended installation. Class A devices are those that may reasonably be expected to be installed in a business or commercial environment. Class B devices are those that may reasonably be expected to be installed in a residential environment (for example, personal computers).

The FCC requires devices in both classes to bear a label indicating the interference potential of the device as well as additional operating instructions for the user.

FCC rating label

The FCC rating label on the device shows the classification (A or B) of the equipment. Class B devices have an FCC logo or ID on the label. Class A devices do not have an FCC logo or ID on the label. After you determine the class of the device, refer to the corresponding statement.

Regulatory compliance notices 93

Class A equipment

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at personal expense.

Class B equipment

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit that is different from that to which the receiver is connected.

Consult the dealer or an experienced radio or television technician for help.

Declaration of conformity for products marked with the

FCC logo, United States only

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.

For questions regarding this product, contact us by mail or telephone:

Hewlett-Packard Company

P. O. Box 692000, Mail Stop 530113

Houston, Texas 77269-2000

1-800-HP-INVENT (1-800-474-6836). (For continuous quality improvement, calls may be recorded or monitored.)

For questions regarding this FCC declaration, contact us by mail or telephone:

Hewlett-Packard Company

P. O. Box 692000, Mail Stop 510101

Houston, Texas 77269-2000

1­281-514-3333

To identify this product, refer to the part, series, or model number found on the product.

Regulatory compliance notices 94

Modifications

The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Hewlett-Packard Company may void the user’s authority to operate the equipment.

Cables

Connections to this device must be made with shielded cables with metallic RFI/EMI connector hoods in order to maintain compliance with FCC Rules and Regulations.

Canadian notice (Avis Canadien)

Class A equipment

This Class A digital apparatus meets all requirements of the Canadian Interference-Causing Equipment

Regulations.

Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.

Class B equipment

This Class B digital apparatus meets all requirements of the Canadian Interference-Causing Equipment

Regulations.

Cet appareil numérique de la classe B respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada.

European Union regulatory notice

This product complies with the following EU Directives:

Low Voltage Directive 73/23/EEC

EMC Directive 89/336/EEC

Compliance with these directives implies conformity to applicable harmonized European standards

(European Norms) which are listed on the EU Declaration of Conformity issued by Hewlett-Packard for this product or product family.

This compliance is indicated by the following conformity marking placed on the product:

This marking is valid for non-Telecom products and EU harmonized Telecom products (e.g. Bluetooth).

This marking is valid for EU non-harmonized Telecom products.

*Notified body number (used only if applicable—refer to the product label)

Hewlett-Packard GmbH, HQ-TRE, Herrenberger Strasse 140, 71034 Boeblingen, Germany

Regulatory compliance notices 95

Disposal of waste equipment by users in private households in the European Union

This symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where you purchased the product.

Japanese notice

BSMI notice

Regulatory compliance notices 96

Korean notice

Class A equipment

Class B equipment

Laser compliance

This product may be provided with an optical storage device (that is, CD or DVD drive) and/or fiber optic transceiver. Each of these devices contains a laser that is classified as a Class 1 Laser Product in accordance with US FDA regulations and the IEC 60825-1. The product does not emit hazardous laser radiation.

Each laser product complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser

Notice No. 50, dated May 27, 2001; and with IEC 60825-1:1993/A2:2001.

WARNING: Use of controls or adjustments or performance of procedures other than

those specified herein or in the laser product's installation guide may result in hazardous radiation exposure. To reduce the risk of exposure to hazardous radiation:

Do not try to open the module enclosure. There are no user-serviceable components

inside.

Do not operate controls, make adjustments, or perform procedures to the laser device

other than those specified herein.

Allow only HP Authorized Service technicians to repair the unit.

The Center for Devices and Radiological Health (CDRH) of the U.S. Food and Drug Administration implemented regulations for laser products on August 2, 1976. These regulations apply to laser products manufactured from August 1, 1976. Compliance is mandatory for products marketed in the United States.

Battery replacement notice

WARNING: The computer contains an internal lithium manganese dioxide, a vanadium

pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack

is not properly handled. To reduce the risk of personal injury:

Regulatory compliance notices 97

Do not attempt to recharge the battery.

Do not expose the battery to temperatures higher than 60°C (140°F).

Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or

water.

Batteries, battery packs, and accumulators should not be disposed of together with the general household waste. To forward them to recycling or proper disposal, please use the public collection system or return them to HP, an authorized HP Partner, or their agents.

For more information about battery replacement or proper disposal, contact an authorized reseller or an authorized service provider.

Taiwan battery recycling notice

The Taiwan EPA requires dry battery manufacturing or importing firms in accordance with Article 15 of the Waste Disposal Act to indicate the recovery marks on the batteries used in sales, giveaway or promotion. Contact a qualified Taiwanese recycler for proper battery disposal.

Power cord statement for Japan

Regulatory compliance notices 98

Electrostatic discharge

In this section

Preventing electrostatic discharge............................................................................................................. 99

Grounding methods to prevent electrostatic discharge ................................................................................ 99

Preventing electrostatic discharge

To prevent damaging the system, be aware of the precautions you need to follow when setting up the system or handling parts. A discharge of static electricity from a finger or other conductor may damage system boards or other static-sensitive devices. This type of damage may reduce the life expectancy of the device.

To prevent electrostatic damage:

Avoid hand contact by transporting and storing products in static-safe containers.

Keep electrostatic-sensitive parts in their containers until they arrive at static-free workstations.

Place parts on a grounded surface before removing them from their containers.

Avoid touching pins, leads, or circuitry.

Always be properly grounded when touching a static-sensitive component or assembly.

Grounding methods to prevent electrostatic discharge

Several methods are used for grounding. Use one or more of the following methods when handling or installing electrostatic-sensitive parts:

Use a wrist strap connected by a ground cord to a grounded workstation or computer chassis. Wrist straps are flexible straps with a minimum of 1 megohm

±

10 percent resistance in the ground cords.

To provide proper ground, wear the strap snug against the skin.

Use heel straps, toe straps, or boot straps at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats.

Use conductive field service tools.

Use a portable field service kit with a folding static-dissipating work mat.

If you do not have any of the suggested equipment for proper grounding, have an authorized reseller install the part.

For more information on static electricity or assistance with product installation, contact an authorized reseller.

Electrostatic discharge 99

Specifications

In this section

Environmental specifications .................................................................................................................. 100

Server specifications............................................................................................................................. 100

Environmental specifications

Specification Value

Temperature range*

Operating 10 ° C to 35 ° C (50 ° F to 95 ° F)

Shipping -40 ° C to 70 ° C (-40 ° F to 158 ° F)

Maximum wet bulb temperature 28

°

C (82.4

°

F)

Relative humidity

(noncondensing)**

Non-operating 5% to 95%

* All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to

3048 m (10,000 ft) is applicable. No direct sunlight allowed.

** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for storage corresponds to a pressure minimum of 70 KPa.

Server specifications

Specification Value

Dimensions

Height

Depth

Width

Weight (maximum: two processors, two power supplies, six hard drives)

Weight (minimum: one processor, one power supply, no hard drives)

Weight (no drives installed)

Input requirement

Rated input voltage

Rated input frequency

Rated input current

4.32 cm (1.70 in)

69.22 cm (27.25 in)

42.62 cm (16.78 in)

17.92 kg (39.50 lb)

14.51 kg (32.00 lb)

14.06 kg (31.00 lb)

100 VAC to 240 VAC

50 Hz to 60 Hz

7.1A (at 120 VAC); 3.5A (at 240 VAC)

Specifications 100

Specification Value

Rated input power 852 W

BTUs per hour 2910 (at 120 VAC); 2870 (at 240 VAC)

Power supply output

Rated steady-state power 700 W

Specifications 101

Technical support

In this section

Related documents ............................................................................................................................... 102

HP contact information.......................................................................................................................... 102

Customer Self Repair ............................................................................................................................ 102

Related documents

For related documentation, refer to the Documentation CD.

HP contact information

For the name of the nearest HP authorized reseller:

In the United States, see the HP US service locator webpage ( http://www.hp.com/service_locator ).

In other locations, see the Contact HP worldwide (in English) webpage

( http://welcome.hp.com/country/us/en/wwcontact.html

).

For HP technical support:

In the United States, for contact options see the Contact HP United States webpage

( http://welcome.hp.com/country/us/en/contact_us.html

). To contact HP by phone:

Call 1-800-HP-INVENT (1-800-474-6836). This service is available 24 hours a day, 7 days a week. For continuous quality improvement, calls may be recorded or monitored.

If you have purchased a Care Pack (service upgrade), call 1-800-633-3600. For more information about Care Packs, refer to the HP website ( http://www.hp.com

).

In other locations, see the Contact HP worldwide (in English) webpage

( http://welcome.hp.com/country/us/en/wwcontact.html

).

Customer Self Repair

HP products are designed with many Customer Self Repair (CSR) parts to minimize repair time and allow for greater flexibility in performing defective parts replacement. If during the diagnosis period HP (or HP service providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship that part directly to you for replacement. There are two categories of CSR parts:

Mandatory—Parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be charged for the travel and labor costs of this service.

Optional—Parts for which customer self repair is optional. These parts are also designed for customer self repair. If, however, you require that HP replace them for you, there may or may not be additional charges, depending on the type of warranty service designated for your product.

NOTE: Some HP parts are not designed for customer self repair. In order to satisfy the customer warranty, HP requires that an authorized service provider replace the part. These parts are identified as

"No" in the Illustrated Parts Catalog.

Technical support 102

Based on availability and where geography permits, CSR parts will be shipped for next business day delivery. Same day or four-hour delivery may be offered at an additional charge where geography permits. If assistance is required, you can call the HP Technical Support Center and a technician will help you over the telephone. HP specifies in the materials shipped with a replacement CSR part whether a defective part must be returned to HP. In cases where it is required to return the defective part to HP, you must ship the defective part back to HP within a defined period of time, normally five (5) business days.

The defective part must be returned with the associated documentation in the provided shipping material.

Failure to return the defective part may result in HP billing you for the replacement. With a customer self repair, HP will pay all shipping and part return costs and determine the courier/carrier to be used.

For more information about HP's Customer Self Repair program, contact your local service provider. For the North American program, refer to the HP website ( http://www.hp.com/go/selfrepair ).

Réparation par le client (CSR)

Les produits HP comportent de nombreuses pièces CSR (Customer Self Repair = réparation par le client) afin de minimiser les délais de réparation et faciliter le remplacement des pièces défectueuses. Si pendant la période de diagnostic, HP (ou ses partenaires ou mainteneurs agréés) détermine que la réparation peut

être effectuée à l'aide d'une pièce CSR, HP vous l'envoie directement. Il existe deux catégories de pièces

CSR:

Obligatoire - Pièces pour lesquelles la réparation par le client est obligatoire. Si vous demandez à

HP de remplacer ces pièces, les coûts de déplacement et main d'œuvre du service vous seront facturés.

Facultatif - Pièces pour lesquelles la réparation par le client est facultative. Ces pièces sont

également conçues pour permettre au client d'effectuer lui-même la réparation. Toutefois, si vous demandez à HP de remplacer ces pièces, l'intervention peut ou non vous être facturée, selon le type de garantie applicable à votre produit.

REMARQUE: Certaines pièces HP ne sont pas conçues pour permettre au client d'effectuer lui-même la réparation. Pour que la garantie puisse s'appliquer, HP exige que le remplacement de la pièce soit effectué par un Mainteneur Agréé. Ces pièces sont identifiées par la mention "Non" dans le Catalogue illustré.

Les pièces CSR sont livrées le jour ouvré suivant, dans la limite des stocks disponibles et selon votre situation géographique. Si votre situation géographique le permet et que vous demandez une livraison le jour même ou dans les 4 heures, celle-ci vous sera facturée. Pour bénéficier d'une assistance téléphonique, appelez le Centre d'assistance technique HP. Dans les documents envoyés avec la pièce de rechange CSR, HP précise s'il est nécessaire de lui retourner la pièce défectueuse. Si c'est le cas, vous devez le faire dans le délai indiqué, généralement cinq (5) jours ouvrés. La pièce et sa documentation doivent être retournées dans l'emballage fourni. Si vous ne retournez pas la pièce défectueuse, HP se réserve le droit de vous facturer les coûts de remplacement. Dans le cas d'une pièce CSR, HP supporte l'ensemble des frais d'expédition et de retour, et détermine la société de courses ou le transporteur à utiliser.

Pour plus d'informations sur le programme CSR de HP, contactez votre Mainteneur Agrée local. Pour plus d'informations sur ce programme en Amérique du Nord, consultez le site Web HP

( http://www.hp.com/go/selfrepair ).

Riparazione da parte del cliente

Per abbreviare i tempi di riparazione e garantire una maggiore flessibilità nella sostituzione di parti difettose, i prodotti HP sono realizzati con numerosi componenti che possono essere riparati direttamente dal cliente (CSR, Customer Self Repair). Se in fase di diagnostica HP (o un centro di servizi o di

Technical support 103

assistenza HP) identifica il guasto come riparabile mediante un ricambio CSR, HP lo spedirà direttamente al cliente per la sostituzione. Vi sono due categorie di parti CSR:

Obbligatorie – Parti che devono essere necessariamente riparate dal cliente. Se il cliente ne affida la riparazione ad HP, deve sostenere le spese di spedizione e di manodopera per il servizio.

Opzionali – Parti la cui riparazione da parte del cliente è facoltativa. Si tratta comunque di componenti progettati per questo scopo. Se tuttavia il cliente ne richiede la sostituzione ad HP, potrebbe dover sostenere spese addizionali a seconda del tipo di garanzia previsto per il prodotto.

NOTA: alcuni componenti HP non sono progettati per la riparazione da parte del cliente. Per rispettare la garanzia, HP richiede che queste parti siano sostituite da un centro di assistenza autorizzato. Tali parti sono identificate da un "No" nel Catalogo illustrato dei componenti.

In base alla disponibilità e alla località geografica, le parti CSR vengono spedite con consegna entro il giorno lavorativo seguente. La consegna nel giorno stesso o entro quattro ore è offerta con un supplemento di costo solo in alcune zone. In caso di necessità si può richiedere l'assistenza telefonica di un addetto del centro di supporto tecnico HP. Nel materiale fornito con una parte di ricambio CSR, HP specifica se il cliente deve restituire dei componenti. Qualora sia richiesta la resa ad HP del componente difettoso, lo si deve spedire ad HP entro un determinato periodo di tempo, generalmente cinque (5) giorni lavorativi. Il componente difettoso deve essere restituito con la documentazione associata nell'imballo di spedizione fornito. La mancata restituzione del componente può comportare la fatturazione del ricambio da parte di HP. Nel caso di riparazione da parte del cliente, HP sostiene tutte le spese di spedizione e resa e sceglie il corriere/vettore da utilizzare.

Per ulteriori informazioni sul programma CSR di HP contattare il centro di assistenza di zona. Per il programma in Nord America fare riferimento al sito Web HP ( http://www.hp.com/go/selfrepair ).

Customer Self Repair

HP Produkte enthalten viele CSR-Teile (Customer Self Repair), um Reparaturzeiten zu minimieren und höhere Flexibilität beim Austausch defekter Bauteile zu ermöglichen. Wenn HP (oder ein HP

Servicepartner) bei der Diagnose feststellt, dass das Produkt mithilfe eines CSR-Teils repariert werden kann, sendet Ihnen HP dieses Bauteil zum Austausch direkt zu. CSR-Teile werden in zwei Kategorien unterteilt:

Zwingend – Teile, für die das Customer Self Repair-Verfahren zwingend vorgegeben ist. Wenn Sie den Austausch dieser Teile von HP vornehmen lassen, werden Ihnen die Anfahrt- und Arbeitskosten für diesen Service berechnet.

Optional – Teile, für die das Customer Self Repair-Verfahren optional ist. Diese Teile sind auch für

Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen

Garantiebedingungen zusätzliche Kosten anfallen.

HINWEIS: Einige Teile sind nicht für Customer Self Repair ausgelegt. Um den Garantieanspruch des

Kunden zu erfüllen, muss das Teil von einem HP Servicepartner ersetzt werden. Im illustrierten Teilekatalog sind diese Teile mit „No“ bzw. „Nein“ gekennzeichnet.

CSR-Teile werden abhängig von der Verfügbarkeit und vom Lieferziel am folgenden Geschäftstag geliefert. Für bestimmte Standorte ist eine Lieferung am selben Tag oder innerhalb von vier Stunden gegen einen Aufpreis verfügbar. Wenn Sie Hilfe benötigen, können Sie das HP technische Support Center anrufen und sich von einem Mitarbeiter per Telefon helfen lassen. Den Materialien, die mit einem CSR-

Ersatzteil geliefert werden, können Sie entnehmen, ob das defekte Teil an HP zurückgeschickt werden muss. Wenn es erforderlich ist, das defekte Teil an HP zurückzuschicken, müssen Sie dies innerhalb eines vorgegebenen Zeitraums tun, in der Regel innerhalb von fünf (5) Geschäftstagen. Das defekte Teil muss mit der zugehörigen Dokumentation in der Verpackung zurückgeschickt werden, die im Lieferumfang enthalten ist. Wenn Sie das defekte Teil nicht zurückschicken, kann HP Ihnen das Ersatzteil in Rechnung

Technical support 104

stellen. Im Falle von Customer Self Repair kommt HP für alle Kosten für die Lieferung und Rücksendung auf und bestimmt den Kurier-/Frachtdienst.

Weitere Informationen über das HP Customer Self Repair Programm erhalten Sie von Ihrem Servicepartner vor Ort. Informationen über das CSR-Programm in Nordamerika finden Sie auf der HP Website unter

( http://www.hp.com/go/selfrepair ).

Reparaciones del propio cliente

Los productos de HP incluyen muchos componentes que el propio usuario puede reemplazar (Customer

Self Repair, CSR) para minimizar el tiempo de reparación y ofrecer una mayor flexibilidad a la hora de realizar sustituciones de componentes defectuosos. Si, durante la fase de diagnóstico, HP (o los proveedores o socios de servicio de HP) identifica que una reparación puede llevarse a cabo mediante el uso de un componente CSR, HP le enviará dicho componente directamente para que realice su sustitución. Los componentes CSR se clasifican en dos categorías:

Obligatorio: componentes para los que la reparación por parte del usuario es obligatoria. Si solicita a HP que realice la sustitución de estos componentes, tendrá que hacerse cargo de los gastos de desplazamiento y de mano de obra de dicho servicio.

Opcional: componentes para los que la reparación por parte del usuario es opcional. Estos componentes también están diseñados para que puedan ser reparados por el usuario. Sin embargo, si precisa que HP realice su sustitución, puede o no conllevar costes adicionales, dependiendo del tipo de servicio de garantía correspondiente al producto.

NOTA: Algunos componentes no están diseñados para que puedan ser reparados por el usuario. Para que el usuario haga valer su garantía, HP pone como condición que un proveedor de servicios autorizado realice la sustitución de estos componentes. Dichos componentes se identifican con la palabra

"No" en el catálogo ilustrado de componentes.

Según la disponibilidad y la situación geográfica, los componentes CSR se enviarán para que lleguen a su destino al siguiente día laborable. Si la situación geográfica lo permite, se puede solicitar la entrega en el mismo día o en cuatro horas con un coste adicional. Si precisa asistencia técnica, puede llamar al

Centro de asistencia técnica de HP y recibirá ayuda telefónica por parte de un técnico. Con el envío de materiales para la sustitución de componentes CSR, HP especificará si los componentes defectuosos deberán devolverse a HP. En aquellos casos en los que sea necesario devolver algún componente a HP, deberá hacerlo en el periodo de tiempo especificado, normalmente cinco días laborables. Los componentes defectuosos deberán devolverse con toda la documentación relacionada y con el embalaje de envío. Si no enviara el componente defectuoso requerido, HP podrá cobrarle por el de sustitución. En el caso de todas sustituciones que lleve a cabo el cliente, HP se hará cargo de todos los gastos de envío y devolución de componentes y escogerá la empresa de transporte que se utilice para dicho servicio.

Para obtener más información acerca del programa de Reparaciones del propio cliente de HP, póngase en contacto con su proveedor de servicios local. Si está interesado en el programa para Norteamérica, visite la página web de HP siguiente ( http://www.hp.com/go/selfrepair ).

Customer Self Repair

Veel onderdelen in HP producten zijn door de klant zelf te repareren, waardoor de reparatieduur tot een minimum beperkt kan blijven en de flexibiliteit in het vervangen van defecte onderdelen groter is. Deze onderdelen worden CSR-onderdelen (Customer Self Repair) genoemd. Als HP (of een HP Service Partner) bij de diagnose vaststelt dat de reparatie kan worden uitgevoerd met een CSR-onderdeel, verzendt HP dat onderdeel rechtstreeks naar u, zodat u het defecte onderdeel daarmee kunt vervangen. Er zijn twee categorieën CSR-onderdelen:

Technical support 105

Verplicht: Onderdelen waarvoor reparatie door de klant verplicht is. Als u HP verzoekt deze onderdelen voor u te vervangen, worden u voor deze service reiskosten en arbeidsloon in rekening gebracht.

Optioneel: Onderdelen waarvoor reparatie door de klant optioneel is. Ook deze onderdelen zijn ontworpen voor reparatie door de klant. Als u echter HP verzoekt deze onderdelen voor u te vervangen, kunnen daarvoor extra kosten in rekening worden gebracht, afhankelijk van het type garantieservice voor het product.

OPMERKING: Sommige HP onderdelen zijn niet ontwikkeld voor reparatie door de klant. In verband met de garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden vervangen. Deze onderdelen worden in de geïllustreerde onderdelencatalogus aangemerkt met "Nee".

Afhankelijk van de leverbaarheid en de locatie worden CSR-onderdelen verzonden voor levering op de eerstvolgende werkdag. Levering op dezelfde dag of binnen vier uur kan tegen meerkosten worden aangeboden, indien dit mogelijk is gezien de locatie. Indien assistentie gewenst is, belt u een HP Service

Partner om via de telefoon technische ondersteuning te ontvangen. HP vermeldt in de documentatie bij het vervangende CSR-onderdeel of het defecte onderdeel aan HP moet worden geretourneerd. Als het defecte onderdeel aan HP moet worden teruggezonden, moet u het defecte onderdeel binnen een bepaalde periode, gewoonlijk vijf (5) werkdagen, retourneren aan HP. Het defecte onderdeel moet met de bijbehorende documentatie worden geretourneerd in het meegeleverde verpakkingsmateriaal. Als u het defecte onderdeel niet terugzendt, kan HP u voor het vervangende onderdeel kosten in rekening brengen.

Bij reparatie door de klant betaalt HP alle verzendkosten voor het vervangende en geretourneerde onderdeel en kiest HP zelf welke koerier/transportonderneming hiervoor wordt gebruikt.

Neem contact op met een Service Partner voor meer informatie over het Customer Self Repair programma van HP. Informatie over Service Partners vindt u op de HP website

( http://www.hp.nl/services/servicepartners ).

Reparo feito pelo cliente

Os produtos da HP são projetados com muitas peças para reparo feito pelo cliente (CSR) de modo a minimizar o tempo de reparo e permitir maior flexibilidade na substituição de peças com defeito. Se, durante o período de diagnóstico, a HP (ou fornecedores/parceiros de serviço da HP) concluir que o reparo pode ser efetuado pelo uso de uma peça CSR, a peça de reposição será enviada diretamente ao cliente. Existem duas categorias de peças CSR:

Obrigatória – Peças cujo reparo feito pelo cliente é obrigatório. Se desejar que a HP substitua essas peças, serão cobradas as despesas de transporte e mão-de-obra do serviço.

Opcional – Peças cujo reparo feito pelo cliente é opcional. Essas peças também são projetadas para o reparo feito pelo cliente. No entanto, se desejar que a HP as substitua, pode haver ou não a cobrança de taxa adicional, dependendo do tipo de serviço de garantia destinado ao produto.

OBSERVAÇÃO: Algumas peças da HP não são projetadas para o reparo feito pelo cliente. A fim de cumprir a garantia do cliente, a HP exige que um técnico autorizado substitua a peça. Essas peças estão identificadas com a marca "No" (Não), no catálogo de peças ilustrado.

Conforme a disponibilidade e o local geográfico, as peças CSR serão enviadas no primeiro dia útil após o pedido. Onde as condições geográficas permitirem, a entrega no mesmo dia ou em quatro horas pode ser feita mediante uma taxa adicional. Se precisar de auxílio, entre em contato com o Centro de suporte técnico da HP para que um técnico o ajude por telefone. A HP especifica nos materiais fornecidos com a peça CSR de reposição se a peça com defeito deve ser devolvida à HP. Nos casos em que isso for necessário, é preciso enviar a peça com defeito à HP dentro do período determinado, normalmente cinco (5) dias úteis. A peça com defeito deve ser enviada com a documentação correspondente no material de transporte fornecido. Caso não o faça, a HP poderá cobrar a reposição. Para as peças de reparo feito pelo cliente, a HP paga todas as despesas de transporte e de devolução da peça e determina a transportadora/serviço postal a ser utilizado.

Technical support 106

Para obter mais informações sobre o programa de reparo feito pelo cliente da HP, entre em contato com o fornecedor de serviços local. Para o programa norte-americano, visite o site da HP

( http://www.hp.com/go/selfrepair ).

Technical support 107

Technical support 108

Technical support 109

Acronyms and abbreviations

ABEND abnormal end

ACU

Array Configuration Utility

AMP

Advanced Memory Protection

ASR

Automatic Server Recovery

BBWC battery-backed write cache

CSR

Customer Self Repair

DDR double data rate

ECC error checking and correcting

ESD electrostatic discharge

HTTP hypertext transfer protocol

IEC

International Electrotechnical Commission iLO 2

Integrated Lights-Out 2

Acronyms and abbreviations 110

IML

Integrated Management Log

ISEE

Instant Support Enterprise Edition

NEMA

National Electrical Manufacturers Association

NFPA

National Fire Protection Association

NIC network interface controller

NiMH nickel metal hydride

NMI non-maskable interrupt

NVRAM non-volatile memory

ORCA

Option ROM Configuration for Arrays

OSEM

Open Services Event Manager

PCI peripheral component interface

PCI Express

Peripheral Component Interconnect Express

PCI-X peripheral component interconnect extended

PCIe peripheral component interconnect express

Acronyms and abbreviations 111

PDU power distribution unit

POST

Power-On Self Test

PPM processor power module

PSP

ProLiant Support Pack

PXE

Preboot Execution Environment

RAID redundant array of inexpensive (or independent) disks

RBSU

ROM-Based Setup Utility

SAS serial attached SCSI

SATA serial ATA

SCSI small computer system interface

SDRAM synchronous dynamic RAM

SFF small form-factor

SIM

Systems Insight Manager

SMTP

Simple Mail Transfer Protocol

Acronyms and abbreviations 112

SNMP

Simple Network Management Protocol

TMRA recommended ambient operating temperature

UID unit identification

UPS uninterruptible power system

VCA

Version Control Agent

VHDCI very high density cable interconnect

WEBES

Web-Based Enterprise Service

WOL

Wake-on LAN

Acronyms and abbreviations 113

Index

A

AC power supply 9

access panel 20

ACU (Array Configuration Utility) 67

additional information 102

ADU (Array Diagnostic Utility) 72

air baffle 20

airflow requirements 25, 26

Array Configuration Utility (ACU) 67

array controller, cabling 61, 62, 63

Array Diagnostic Utility (ADU) 72

ASR (Automatic Server Recovery) 69

authorized reseller 102

auto-configuration process 66

Autorun menu 65

B

battery 97

battery-backed write cache battery pack 50, 63

BIOS Serial Console 67

BIOS upgrade 69

BSMI notice 96

buttons 7, 8, 10

C

cables 61, 63, 64, 79, 95

cabling 28, 61, 63, 64

cache module 50

Canadian notice 95

Care Pack 24, 75

cautions 77

Change Control 75

changing the USB speed 72

component identification 7, 9, 15 components 7, 9

configuration of system 29, 65

configuration tools 65

connection problems 79

connectors 7, 8, 9, 10

CSR (customer self repair) 102 customer self repair (CSR) 102

D

Declaration of Conformity 94

diagnosing problems 76, 79

diagnostic tools 65, 69, 72, 73

diagnostics utility 73

DIMMs 36, 37

drivers 74

E

electrical grounding requirements 26

electrostatic discharge 99

environmental requirements 25, 100

environmental specifications 100

Erase Utility 70

error messages 91

European Union notice 95

expansion boards 44, 45, 47

extending server from rack 19

external health LED 8

F

fan modules, installation 22 fan modules, removal 22

features 7

Federal Communications Commission (FCC)

notice 93, 94, 95

flash ROM 69

flowcharts 80, 81, 83, 86, 87, 89

front panel buttons 8

front panel components 72

front panel LEDs 8

G

general diagnosis flowchart 81

grounding requirements 26

H

hard drive bezel blanks 39 hard drive blanks 39

hard drive LEDs 15

Index 114

hard drives 14, 15, 38, 40

hard drives, determining status of 15

hard drives, installing 40

hardware options 31

hardware options installation 27, 31

health driver 13, 69

HP Insight Diagnostics 73

HP ProLiant Essentials Foundation Pack 70

I

identification number 93

iLO 2 (Integrated Lights-Out 2) 9, 69

iLO 2 activity LED 10 iLO 2 link LED 10

IML (Integrated Management Log) 73

Important Safety Information document 76

Insight Diagnostics 73

installation services 24

installation, server options 27, 31

installing hardware 31

Integrated Lights-Out (iLO) 69

Integrated Management Log (IML) 73

internal health LED 13

internal USB functionality 72

J

Japanese notice 96

K

keyboard connector 9

Korean notices 97

L

laser devices 97

LEDs 7, 15

LEDs, hard drive 15

LEDs, Systems Insight Display 12, 13

LEDs, troubleshooting 76

M

Management Agents 70

management tools 69

memory 36, 37 memory, Advanced ECC 36, 37

memory, configuration requirements 37

mouse connector 9

multibay blank, removing 41

N

NIC LEDs 8, 9, 10

NMI jumper 12

O

Online ROM Flash Component Utility 69, 70, 75

operating systems 29, 74

optimum environment 25

Option ROM Configuration for Arrays (ORCA) 68

options installation 27, 31

ORCA (Option ROM Configuration for Arrays) 68

OS boot problems flowchart 87

P

PCI array controllers, cabling 61

PCI riser board assembly 21, 22

PCI-X riser board 45

POST error messages 91

POST problems flowchart 86

power cord 77, 98

power distribution unit (PDU) 26

power LEDs, system 8, 9, 10

Power On/Standby button 8, 18, 29

power supplies 42

powering down 18 powering up 18, 66

PPM failure LEDs 14

preparation procedures 79

problem diagnosis 76

processors 31

ProLiant Support Pack (PSP) 74

PSPs, overview 74

R

rack installation 24, 27, 28

rack resources 25

rack stability 77

rack warnings 27, 77

RBSU (ROM-Based Setup Utility) 66

rear panel buttons 9, 10 rear panel components 9

rear panel LEDs 10

redundant power supply configurations 42

redundant ROM 70

registering the server 30

regulatory compliance notices 93, 95

remote support and analysis tools 73, 74

Resource Paqs 74

Index 115

ROM redundancy 70

ROM, updating 69, 75

ROMPaq utility 69, 70

S

safety considerations 27, 76

SAS device numbers 14

SAS hard drive 40

SAS hard drive LEDs 15

SATA drives 14

SATA hard drive 15, 40

SATA hard drive LEDs 15

scripted installation 65

serial number 68

series number 93

server features and options 31

service notifications 79

SmartStart autorun menu 65

SmartStart Scripting Toolkit 65

SmartStart, overview 65

space requirements 25

specifications, environmental 100 specifications, server 100

start diagnosis flowchart 80

static electricity 99

support 73, 102

support packs 65

supported operating systems 74

Survey Utility 72

symbols on equipment 77

system board components 12 system maintenance switch 12

system power LED 8, 12

Systems Insight Display 12

Systems Insight Display LEDs 12, 13

T

Taiwan battery recycling notice 98

technical support 102 telephone numbers 102

temperature requirements 26

troubleshooting 76

U

UID LEDs 7, 18

updating the system ROM 70

USB speed, changing 72

USB support 71

utilities 65 utilities, deployment 65, 66

V

ventilation 25

video connector 10

W

warnings 27, 77

Index 116

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!