Focus FC-7564 User manual
Add to my manuals34 Pages
Focus FC-7564 is a versatile alarm control system that combines burglary, fire, and gas leak protection with a user-friendly interface and multiple arming and disarming options. Featuring 16.4 programmable zones, it allows for a mix of wired and wireless sensors and supports up to 8 LCD keypads and 8 remotes for convenient control. With 2 CMS follow-me numbers, an account number, and 4 voice numbers, the system provides comprehensive alarm notification options, including phone calls, SMS, GPRS, and TCP/IP (optional).
advertisement
FC-7564
user manual
POWER
COM
DISARM
ARM
ALARM
FAULT
P/N 20120815-A
FC-7564 WIRING DIAGRAM
LED display on Metal case GSM LED Flash
AC AC
+BELL-
KEY+ GND
T X RX +12V GND A B Z1 GND Z2 Z3 GND
13VAC 2A
Power
Disarm
Frice Panic
Delete
Medical
Confirm
Check
#
Arm
Disarm
Home
Bypass
Arm
Fault
Aux power output
BUS
2.2K 2.2K
2.2K 2.2K
2.2K 2.2K
2.2K 2.2K
Power supply
Only can use12V/7A sealed lead-acid battery,change battery every 3-5 years
With 1 keypad,power consumption 250mA,support for 16 working hrs.
Total power consumption(keypad,auxiliary power,siren)can~t exceed max.power
consumption of control panel
Max.Rechargeable current of battery:350MA
Content
Foreword 1
Features 2
Alarm procedure 3
1.Remote control by phone 4
2.Follow me operation 4
GSM remote operation 6
GSM alarm receiving 6
GSM control via SMS 6
Keypad 7
LED display on Metal case 8
C7601 BUS zone expander 9
Basic operation 10
System setting 11
I.Set password 12
1.1 Set administrator password 12
1.2 Set user password 12
II.set CMS number 12
2.2 Set user Id 13
2.3 Free arm telephone number 13
2.4 Free disarm telephone number 13
2.5 Set the user telephone number 1 3
2.6 CMS dialing times 14
2.7 The user phone dialing time 1 4
III.System options 1 4
3.1 System time setting 1 4
3.2 Entry delay time setting 1 4
3.3 Set exit delay time 15
3.5 Set ring time 15
3.6 Detector loss check 15
3.7 Communication checking interval time 16
3.8 Arm,disarm indication sound 1 6
3.9 Arm/disarm report 16
3.10 Panic alrm sound 16
IV. Code wireless device 17
4.1 Code wireless remote controller 17
4.2 Auto code wireless detector 17
4.3 Manual code remote controller 17
4.4 Manual code wireless detector 18
4.5 Delete remote controller 1 8
4.6 Delete detectors 18
V.System zone setting 18
5.1 Zone type setting 19
5.2 Zone siren type setting 19
5.3 Wired zone loop type 19
5.4 The response speed of wireless 20
VI.Other options setting 20
6.1 AC power fault report delay 20
6.3 Force arming 21
6.4 Cross protection areas 21
VII.GSM setting 22
7.1 GSM module set 22
7.2 GSM information setting 22
7.3 Alarm priorities 23
7.4 GSM message language 23
7.5 DTMF output signal strength 23
7.7 GPRS setting 24
7.8 Server IP address 24
7.9 Server port 24
7.10 Server registered ID 25
7.11 Server registered passwordh 25
7.12 Server connection 25
Technical specification 26
Maintenance and protection 26
Limitation of the Products 27
Foreword
User manual
Foreword
FC-7564 is a intelligent alarm control system which in tegrated with burglarproof, fireproof, gas leak proof. It is compatible with wired and wireless alarm mode.
FC-7564 refers to the most advanced coding techniques of BUS zone and multi-bit random code-hopping techniques in security & reliability, to avoid false alarm and interf erence effectively.
1.64 zones:8 wired, 24 wireless and 32 BUS zone
2.6 way to arm and disarm the system: User code, Keyfob, Phone,
SMS, Auto timer, CMS
3.Alarm notification: When alarm occurs, user can have alarm
notification by phone call, SMS, GPRS, TCP/IP(optional)
Smart feature of FC-7564
1. Multi-zones combination alarm, special design for the places suchas watchroom, bedromm and etc.
2.Can use without keypad
3.LED display on metal case, easier for user to check system info.
Warning!!!
Don t disassemble or modify, or else may be lead to danger and
the damage of panel.
Be sure not to cause to break by falling or throwing down or
strong impacting. Not install near the magnetic field, may
because instability.
Keep dry and clean. Don t install the panel in the site which has
oily fume, water-vapour, much poudre.
Be keep out of the sun and heat. Don t install the panel near the
heating stove etc. high temperature equipment, such as spotlight.
Keep out of the direct sunlight, may cause color fading.
When cleaning, wipe with the mull. To remove dirt need to use
detergent, don t use gasoline or paint thinner etc. chemicals. Or
else may cause damage or the paint scaled off the panel.
User manual
Features:
Zones: 8 wired/24wireless/32BUS zone
Keypad and remote: Support pcs LCD keypad and 8remotes
Password: 1 installer code, 1 duress code, 15 user codes
CMS: 2 CMS follow me numbers,
1 account number
Voice number:
4 voice numbers, Voice prompting operation
Event log:
128 event logs
Module expanded: GSM/GPRS module
Recording:10-second automatic message Recording
Features
User manual
Alarm procedure
Tele Telephone telephone
Cell phone
Alarm procedure
1st 2nd 3rd 4th
3.The panel will dial 1-4 telephone numbers as preset.If more than 4 numbers,the panel will start with second telephone number, then 3,4...
W ir ed
BUS
Alarm software
Alarm situation found, start to send message
POWER
COM
DISARM
ARM
ALARM
FAULT
1.The detector activated send alarm information to alarming center
CMS
110 alarm center
2.The panel use Ademco Contact ID to send alarm information to alarming center.
If the panel got confirmation from center, then alarm successfully.Otherwise, the panel will repeat alarm.The alarm information will be display and reslove by the alarm center computer software.
wi re les s
User manual
Remote control by phone
1 Remote control by phone
1 2
User to call landlines phone which connect to the panel
When user answer the call,the panel pick up phone after preset rinings
3
" W e l c o m e t o y o u r s e c u r i t y s y s t e m E n t e r y o u r u s e r c o d e "
4
1 2 3 4
Enter the user code as per voice prompting(factory default
code: 1234)
System disarm, press one
System arm, press two
System home arm, press three
Play the zone address recording, press nine
Hang up, press zero
5
2 Follow me operation
When the detector is triggered, the panel will sound alarm and display the triggered zone number and alarm type on the LCD screen. The panel will give a alarm and dial the preset voice numbers if the panel received the alarm.
The user can hear indication after he took th e phone.The user operate follow the voice indication to disarm/arm inquire and mornitor .
1 2
POWER
COM
DISARM
ARM
ALARM
FAULT
S e n d t h e a l a r m s i g n a l
P a n e l r e c e i v e a l a r m , a n d d i a l v o i c e n u m b e r
User manual
3
U s e r a n s w e r t h e c a l l
Cancel the alarm press one
Check alarm zone press two
Activate the hoot press three
To disable the siren press four
Disarm system press five
Arm the system press six
Stay arm the system press seven
Play the zone address recording press nine
Hand up press zero
Follow me operation
4
User manual
GSM remote operation
GSM remote operation
You can SIM card number,then panel will off revised user password,the default password is 1234,as
press 1 to disarm
press 2 to arm
press 3 to home arm
press 0 to hangup
GSM alarm receiving
When alarm occurs,GSM will call the preset voice number,it will voice prompt system is alarm,please process the alarm press one to cancel alarming press two to check alarm zone press three to trigger siren press five to disarm press six to arm press seven to home arm
GSM control via SMS
Arm command PASSWORD:1234 SYSTEM ARM
Disarm command PASSWORD:1234 SYSTEM DISARM
Home arm command
PASSWORD:1234 SYSTEM HOME
Status checking command
PASSWORD:1234 SYSTEM STATUS
Cancel alarm command
PASSWORD:1234 SYSTEM CANCEL
Note:There is no space in the command password:1234 ,There is a space between
system and arm.enter system arm ,when operate successfully,SMS auto reply
Arm Successful .
Set GPRS access command PASSWORD:1234 APN: aaaaaa
Set GPRS access User name command PASSWORD:1234 USER: bbbbbb
Set GPRS access User code command PASSWORD:1234 PWD: cccccc
Remarks:There is no space between APN:
User manual
Keypad
Keypad description
Power LED
Disarm LED
Numeric keyboard
Power
Disarm
Frice
Delete
Panic Medical
Confirm
Check
#
Arm
Disarm
Home
Bypass
Arm
Fault
Arm LED
Fault LED
Speech indication
Power LED: it will normal ON when AC and battery without any trouble. It will off
when both AC and battery with trouble. It will slow flash when battery
with trouble, it will quick flash when AC with trouble.
Fault LED: It will slow flash when communication with trouble, it will off when
without any troubles.
Arm LED: It will ON when armed, slow flash when stay in, quick flash when alarm.
Disarm LED: It will ON when disarmed, it will OFF when zone trouble.
Fire
: The panel will send out alarm
signal when press FIRE key 3 for
seconds, it used as UP key when
programming.
Panic
: The panel will send out alarm
signal when press PANIC key for 3
seconds, it used as DOWN key
when programming.
Medical
: The panel will send out alarm
signal when press HELP key for 3
seconds, it used as DELETE key
when programming.
Check : Press CHECK key to check the
alarm events , it used as Confirme
key when programming.
press , the LCD screen will
display P, means 2s pause
when dialing, for other settings,
press means EXIT.
:When enter errors, press # can
delete the errors, it used as
Confirm key when programming.
Basic operation
Factory default Admin password: 012345
Factory default User password: 1234
Arm: User password[1234]+ Arm
Home: User password[1234]+ Home
Disarm: User password[1234]+
Disarm
LED display on Metal case
User manual
Enter system setting : Admin password[012345]+
#
*
+[0]+
Exit system setting:
*
#
Password reset: You can enter installer code 000000 to enter setup only during the
first 1 minute when the alarm is powered on.
LED display on Metal case
Disarm
Power
Comm
Alarm
Fault
Arm
POWER LED it will normal ON when AC and battery without any trouble. It will off
when both AC and battery with trouble. It will slow flash when battery
with trouble, it will quick flash when AC with trouble.
FAULT LED: It will ON when zone troubles.
ARM LED: It will ON when armed, slow flash when stay in.
DISARM LED: It will ON when disarmed
COMM LED: It will flash when communication trouble.
ALARM LED: It will flash when alarm.
Zone trouble indication it means that 8 zone alarm it means that 8 zone trouble it means that 8 zone bypass
Note: if the LCD also display zone alarm when the user disarmed the system after
alarming, please disarm the system again, then LCD display will resume.
User manual
FC-7601 BUS zone expander
(Fig 1)
FC-7601 BUS zone expander
1.FC-7601 is single zone module via dip switch address, EOL 10k
2.Zone expanded :NO.1-128
3.Wire: red(DC+), Brown(DC-), Yellow(A), White(B), Green( zone inspection)
Brown also GND.
4.Working voltage: DC8.5-24V
5.DIP 1 tamper inspection switch, ON to enable tamper, OFF-to disable tamper
2-8 address digit. OFF enable, ON-disable. Binary address, To set zone 18, user should be put DIP 4 and DIP 8 to be OFF,See (fig 1) allmodule address should be plus one.
6.The zone number in BUS module=module address number + , Eg. Zone 50=module address 18+40
32
7.Zone 33-64 is disable by factory default, user should enable firstly before use.
FC-7601
SINGLE ZONE
NO TAMPER
FC-7601
SINGLE ZONE
TAMPER
User manual
Basic operation
Arm
Power
Disarm
Frice Panic
Delete
Medical
Confirm
Check
#
Arm
Disarm
Home
Bypass
Arm
Fault
¡«
àÖ
¡«
Y
M D
Basic operation
Disarm
Power
Disarm
Frice Panic
Delete
Medical
Confirm
Check
#
Arm
Disarm
Home
Bypass
Arm
Fault
¡«
àÖ
¡«
Y
M D
ARM button in the keyfob
Emergency
Power
Disarm
Frice
Delete
Panic Medical
Confirm
Check
#
Arm
Disarm
Home
Bypass
Arm
Fault
DISARM button on the keyfob
Stay arm
Power
Disarm
Frice Panic
Delete
Medical
Confirm
Check
#
Arm
Disarm
Home
Bypass
Arm
Fault
Y
M D
Y
M D
Emergency help:press key in the keyfob
ARM key in the keyfob.
Note: If the LCD also display zone alarm when the user disarmed the system after
alarming, please disarm the system again, then LCD display will resume.
System setting
User manual
System setting
[012345] +
+
[0] +
*
System setting display
2
0 6
0
5
Programming address
Set data Data bit
System menu and programming address
01-- Set admin password
02-- 17Set user password
20--21 Set CMS
22-- Set user No.
23--26 Set user phone number
27-- Set CMS dialing times
28-- Set user phone dialing times
30-- Set system time
31-- Set enter delay time
32-- Set exit delay time
33-- Siren time
34-- Ring times
35-- Check sensor loss
36-- Communication testing time
37-- Arm/disarm tone
38-- Arm/disarm report
39-- Panic alarm tone
40-- Auto program remote
41-- Auto program sensor
42-- Enter remote code
43-- Enter sensor code
44-- Delete remote
45-- Delete sensor
50-- Set zone type
51-- Set siren type
52-- Wired zone loop type
53-- Wired zone response time
60-- Force arm
61-- Call back specified number
62-- Set free arm phone number
63-- Set free disarm phone number
70-- The first group cross zone
71-- The second group cross zone
72-- The third group cross zone
80-- Set GSM
81-- Set GPRS
82-- Alarm priority
83-- Set GSM info
84-- Server IP address
85-- Server port
86-- Server register ID
87-- Server register password
88-- Server connection mode
89-- DTMF output signal strength
90-- Handshake tone input signal
strength
91-- SMS language
98-- AC off delay report
99-- Time calibration
Set password
User manual
I.Set password
1.1 Set administrator password
For example: set the administrator password as 112233, the factory default password
is 012345.
[012345]
+
*
+
[0]
+
----
+
[01]
+
[112233]
Password
LCD screen display
01 3
06 +
LCD screen display
Press return to standby interface
*
+
1.2 Set user password the factory default password:1234
For example:set the NO.3 user password as 5678
[012345]
+
*
04 8
04
+
+
[0]
+
----
+
[04]
+
[5678]
Press
return to standby interface
*
+
NOTE:User can set 16 user passwords,the program address:02-17
II.Set CMS number
2.1 Set CMS number
For example:set the CMS number as 9P80012345
[012345]
+
*
+
[0]
+
20
11 +
----
+ [20]
+
Program address
*
Telephone
number
Press
return to standby interface
*
+
Note: user can set 2 CMS numbers,the program address:20-21 when press
LCD screen dispaly asP it means dial pause 2 seconds.
*
The dial pause only for connecting with extensions otherwise,press 80012345 directly.
set CMS number
User manual
2.2 Set user ID the factory default setting :0000
Example: set the user ID as 6666
[012345]
+
*
+
[0]
+
----
+ [22] +
Program
LCD screen
address
display
[6666]
User ID
22
05 +
LCD screen dispaly
Press
return to standby interface
*
+
2.3 Free arm telephone number
Example: set the free arm telephone number as 84113252
[012345]
+
*
+
[0]
+
----
+
[62]
+
[84113252]
62
09
+
Press +
return to standby interface
*
2.4 Free disarm telephone number
Example: set the free disarm telephone number as 84113268
[012345]
+
*
+
[0]
+
----
+
[63]
+
[84113268]
63
09 +
Press
+
return to standby interface
*
2.5 Set the user telephone number
Example: set the NO.3 user telephone number as 93872105
[012345]
+
*
+
[0]
+
----
+ [25] + [93872105]
25
09
+
Press
+
return to standby interface
*
Note:user can set 4 user telephone numbers,the program address:23-26
system options
User manual
2.6 CMS dialing times.The default setting is 5 times
Example:set the dialing time as 4 times.
[012345]
+
*
27 4
02
+
+
[0]
+
----
+
[27]
+
[04]
Press
return to standby interface
*
+
2.7 The user phone dialing time:the default setting is 5 times
Example: set the dialing time as 3 times
[012345]
+
*
28 3
02
+
+
[0]
+
----
+
[28]
+
[03]
Press *
+
III.System options
3.1 System time setting
return to standby interface
Example: set the system time and date as 10:01,July,11,2012
[012345]
+
*
+
[0]
+
----
+ [30]
+ [1207111001]
H M
30 1
Year Month Day Hour Minute
10
+
Press return to standby interface
*
+
3.2 Entry delay time setting:after triggerd the delay zone,panel start
alarming.the default setting is 10 seconds.
Example: set the entry delay time as 15 seconds.
[012345]
+
31 5
03 +
*
LCD screen dispaly
Press *
+
+ [0] +
----
+
[31]
+
Program
LCD screen
address
dispaly
[015]
Time
return to standby interface
system options
User manual
3.3 Set exit delay time:the default setting is 10seconds.
Example: set the exit delay time as 15 seconds.
[012345]
+
32 5
03 +
*
+
[0] +
----
+
[32]
+
[015]
Press
return to standby interface
*
+
3.4 Siren time the default setting is 5mins
Example: set the siren time as 10 mins
[012345]
+
33 0
02
+
*
+
[0]
+
----
+ [33] +
[10]
Press
return to standby interface
*
+
3.5 Set ring time the default time is 7times
Example: set the ring time as 5 times.
[012345]
+
34 5
02
+
*
+
[0]
+
----
+
[34]
+
Program
LCD screen
dispaly
address
[05]
Time
LCD screen dispaly
Press *
+
return to standby interface
3.6 Detector loss check the default setting is00 as Disable
Example:set the detector loss check time as 4hours
[012345]
+
35 4
02 +
*
+
[0]
+
----
+ [35] +
[04]
return to standby interface
Press
* +
system options
User manual
Note: wireless detector send status report about every 3 hours. The panel check if receiver
the status report signal or alarm signal from detector at programed time. If not
receive the singal, will judge detector loss. We suggest set the neterval time of
detector inspection longer than 4 hours.
3.7 Communication checking interval time
:
It is checking of communication between alarm panel and CMS. To check if the
communication is normal(default is 00, not checking)
Example: set the communication checking interval time as 15 hours.
[012345]
+
36 5
03 +
*
+
[0]
+
----
+ [36] + [015]
return to standby interface
Press *
+
3.8 Arm, disarm indication sound
:
To set if the siren sound when user use remote controller to arm,disarm the panel
(default: not sound)
0> not sound 1>sound
Example: set the arm /disarm indication sound on
[012345]
+
37 1
01
+
*
+
[0]
+
----
+ [37] +
[1]
return to standby interface
Press *
+
3.9 Arm/disarm report(default: not report to CMS)
0> not report 1> report
Example: set arm/disarm report CMS
[012345]
+
38 1
01
+
*
+
[0]
+
----
+ [38] +
Program
LCD screen
dispaly
address
[1]
1>Report
LCD screen dispaly
return to standby interface
Press *
+
3.10 Panic alrm sound:
To set if the siren sound when trigger the panic button on remote controller or
emergency button on keypad(default: OFF)
0> OFF 1> ON
system options
User manual
Example: set the panic alarm sound on
[012345]
+
39 1
01
+
*
+
[0]
+
----
+ [39] +
[1]
Press
return to standby interface
*
+
IV. Code wireless device
4.1 Code wireless remote controller
Example: auto code number 5 remote
[012345]
+
40 5
01
+
*
+
[0]
+
----
+ [40] +
[5]
40 1
01
+
Trigger remote
controller
1
01
is the first number of remote is 9 digit address code
Press
*
+
return to standby interface
4.2 Auto code wireless detector
Example: auto code number 9 wireless detector
[012345]
+
41 9
02
+
*
+
[0]
+
----
+ [41] +
[09]
41 2
01
+
Press +
return to standby interface
*
4.3 Manual code remote controller
Example: manual code the first remote controller by enter address code of remote
077230023
2
01
is the first number of
Trigger wireless is 9 digit address code wirelers detector
[012345]
+
42 1
01
+
*
+ [0] +
----
+ [42]
+
[1]
[077230023] 41 3
09
+
Press
*
+
return to standby interface
system zone setting
User manual
4.4 Manual code wireless detector
Example: manual code the number 24 wireless detector by enter the address code
035126025
[012345]
+
43 4
02
+
*
+
[0]
+
----
+ [43] + [24]
[035126025] 43 5
09
+
Press
*
+
return to standby interface
4.5 Delete remote controller
Example: delete the number 8 remote controller
[012345]
+
44 8
01
+
*
+
[0]
+
----
+ [44] +
[8]
LCD screen
Program
Address
code
dispaly
address
LCD screen dispaly
Press
*
+
return to standby interface
Note: enter 0 to delete all remote controller
4.6 Delete detectors
Example: delete number 11 detector
[012345]
+
45 1
02
+
*
+ [0] +
----
+
[45]
+
Program
LCD screen
dispaly
address
[11]
Address
code
LCD screen dispaly
Press
+
return to standby interface
*
Note: enter 00 to delete all detectors
V.System zone setting
5.1 Zone type setting
Options of zone type as below
0>disable 1>delay 2>perimeter
3>burglar 4>24 hours 5> emergency
6> fire alarm
For example: set protection area 7 and 8 as one group of the double direction one-shot
mode cross protection area. Preset time is 50 seconds.
system zone setting
User manual
Burglar alarm zone only trigger under system arm status, delay and perimeter zone trigger under stay or arm status.
24 hours, emergency and fire alarm zone will trigger under any system status
Factory default:
Wired zone 1-8 enable, wireless zone 9-32 enable, bus zone 33-64 disable, 00 is system zone. Pls connect resistor 2.2k to wired zone before power on the alarm panel, otherwiset he alarm panel will make alarm or cause zone trouble. When need use bus zone, 7601 one zone expand module is required.
Example: set the number 59 zone as fire alarm zone
[012345]
+
+
[6]
Type
*
+
[0]
+
50 6
03
+
LCD screen dispaly
Press
*
+
----
+ [50] +
[59]
Program
Zone
LCD screen
dispaly
return to standby interface
address
The LCD will display the zone type.
5.2 Zone siren type setting(default continious sound)
The options of siren type:
0>mute 1> continious sound 1> pulse tone
Example set zone 33 siren type as pulse tone
[012345]
+
+
[2]
Type
*
+
[0]
+
51 2
03
+
Press
----
+ [51] +
LCD screen
dispaly
*
LCD screen dispaly
+
return to standby interface
Program
address
[33]
Zone
the LCD will display the siren type
5.3 Wired zone loop type(default: resistor loop)
The options of wired zone loop type:
0>N.O loop, zone open loop normal, short-cut loop alarm
1>N.C loop, zone short-cut loop normal, open loop alarm
Other options setting
User manual
Eol resistor N.G wiring Eol resistor N.O wiring
For example: set the protection area No.6 as N.C loop
[012345]
+
*
+
[0]
+
52 2
02
+
----
+ [52] +
[6]
+
[2]
Press +
return to standby interface
*
loop type after inputting the protection area number
5.4 The response speed of wireless protection area (default is 500ms)
Configurable response speed of wireless protection area as below
For example: set the response speed for protection area No.3 is 10ms, Screen shows
[012345]
+
*
+ [0] +
53 1
02
+
----
+ [53] +
Program
LCD screen
dispaly
address
[3]
Zone
+
[1]
1>10ms
LCD screen dispaly
Press
*
+
return to standby interface
Note: If only can see the response speed of wireless areas, after inputting the protection
s response speed is 500ms, 10ms for High speed detectors and vibration sensors.
.
VI.Other options setting
6.1 AC power fault report delay:
when there is AC power fault occurs, the
delay time for reporting to the alarm receiving centre default for 30 minutes.
For example: set the delay time of AC power fault report is 5 minutes
[012345]
+
*
98 5
02
+
+
[0]
+
----
+ [98] + [05]
return to standby interface
Press
*
+
Other options setting
User manual
Note: if the delayed time setting is 0 minutes, it means that it will not report the power
fault information.
6.2 Time calibration
For example: If the panel time every 24 hours fast 20 seconds, take the formula
20x100/24=83 to calibrate, then set this value is 083. If slows 20 seconds, then
it is 183 to calibrate the time.
[012345]
+
*
+
[0]
+
----
+ [99] + [083]
99 3
03
+
Press
*
+
return to standby interface
6.3 Force arming:
Allow users to arm when protection area faults. In the state of
the arming, the protection areas and recovery information will report to alarm
receiving centre. Default is disable.
0>Disable force arming 1>Enable force arming
For example: set enable force arming
[012345]
+
60 1
01
*
+ [0] +
----
+
[60]
+
[1]
+
Press
*
+
return to standby interface
6.4 Cross protection areas: protection area 1+protection area 2 + time + mode.
Configurable cross protection area mode as below
0>Cancel cross model
1> The double direction twice-trigger mode : single trigger protection area 1, 2,
it will not alarm, trigger first protection 1, then trigger protection area 2 within
preset time, it will alarm; first trigger protection area 2 then area 1, it will not alarm.
2>The double direction One-Shot mode: trigger protection area 1, protection area 1
alarm; trigger protection area 2 first then protection area 1 within preset time, then
it will not alarm; trigger protection area 1 behind the preset time, the protection
area 2 will alarm.
3>Twice-trigger alarm mode: one-shot trigger protection are 1 or 2, it will not alarm,
trigger protection area 1 and 2 in preset time separately, then protection area 1 and
2 alarm.
GSM setting
User manual
[012345]
+
70 2
08
*
+
+
[0]
+
----
+
[70]
+
[07080502]
Zone 1
Zone 2
Time Mode
Press return to standby interface
*
+
Note: It can set 3 groups of cross protection areas. The corresponding No is 70-72
6.5 Dial back specific No.
: dial telephone No. that connected with panel, input the
# s password after off-hook. It will be on-hook automatically
and the panel will call the preset the telephone No. which can execute the arm and
disarm operation in a long distance.
For example: set the dial back telephone No. is 12345678.
[012345]
+
61
09
*
+
[0]
+
----
+ [61] + [12345678]
+
Press return to standby interface
*
+
VII.GSM setting
7.1 GSM module set (default is disable)
Disable Enable
For example: set enable GSM module.Configurable GSM information as below.
[012345]
+
80 1
01
*
+
[0]
+
----
+ [80] + [1]
+
LCD screen dispaly
Press return to standby interface
*
+
7.2 GSM information setting (default is SMS + voice calling)
SMS + voice calling SMS
For example: set only can dial voice calling.
Voice calling
GSM setting
User manual
[012345]
+
83 2
01
*
+
+
[0]
+
----
+ [83] +
Program
LCD screen
dispaly
LCD screen dispaly
return to standby interface
Press
*
+
7.3 Alarm priorities (default is GSM priority)
GSM priority PSTN priority
For example: set telephone line is priority
address
[2]
Type
[012345]
+
82 1
01
*
+
[0]
+
----
+ [82]
+
[1]
+
Press
*
+
return to standby interface
7.4 GSM message language (default is Chinese)
Configurable SMS language as below
Chinese English
For example: set message as English
[012345]
+
*
91 1
01
+
+
[0]
+
----
+ [91] +
[1]
Press
+
return to standby interface
*
7.5. DTMF output signal strength(default is 04)
For example: set DTMF output signal strength is 05
[012345]
+
*
89 5
02
+
+
[0]
+
----
+ [89] +
Program
LCD screen
address
dispaly
[05]
Signal stregth
LCD screen dispaly
Press
+ *
return to standby interface
GSM setting
User manual
7.6 Hand skake voice input signal strength (default is 60)
For example: set handshake voice input signal strength is 70
[012345]
+
90 0
02
*
+
[0] +
+
----
+
[90]
+
[70]
Press
*
+
return to standby interface
7.7 GPRS setting (default is disable)
Disable Enable
For example: set enable GPRS function.
[012345]
+
81 1
01
*
+
[0]
+
----
+ [81] +
[1]
+
Press
+ *
7.8 Server IP address
return to standby interface
For example: set Server IP address is 202.101.78.2
[012345]
+
*
+ [202101078002]
+
[0]
+
84 2
12
----
+ [84]
+
Press
*
+
return to standby interface
7.9 Server port
For example: set Server port is 03467
[012345]
+
85 7
05
*
+ [0] +
----
+
[85]
+
[03467]
+
return to standby interface Press
*
+
GSM setting
User manual
7.10 Server registered ID
For example: set server registered ID is 75640001
[012345]
+
*
86 1
08
+
[0]
+
+
----
+ [86] +
Program
LCD screen
address
dispaly
[75640001]
User ID
LCD screen dispaly
Press
+
return to standby interface
*
7.11. Server registered password
For example: set Server registered password is 12345678
[012345]
+
*
+
[0]
+
87 8
08
+
----
+ [87] + [12345678]
return to standby interface
Press
*
+
7.12 Server connection (default is long connection)
Configurable comection method mode as below
Long connection Short connection
For example: set connection is short one
[012345]
+
*
88 1
01
+
+
[0]
+
----
+ [88] +
[1]
Press
*
+
return to standby interface
Note: Enable GPRS function need to enable GSM module.
Long connection: do not deal with SMS, voice calling and Server, via GPRS
long connection.
Short connection: when it have voice calling and SMS, the system will cut off connection
with GPRS, and deal with the voice calling and SMS priority. When this is done, GPRS
will connect with Server automatically.
Server registered ID and password: GPRS can registered must have the correct ID and
password that registered in the Server. it must be 8 digitals for the ID and passwords.
User manual Technical specification
General data
Technical specification
Output: 13VAC/2A
Backup power supply duration:16 hours
Backup battey(optiond):
12V/7AH
The method of alarming dial: Telephone alarm GSM alarm and
GPRS alarm
DTMF dial frequency variation :< 1.5%
Communication Protocol with CMS: Ademco Contact ID
Frequency:
433MHz/868MHz
E Signal transmit distance: 100 to 120 meters (open area)
32F to 120F 0 to 45
-4F to140F -20 to 60
Relative humidity: 85% at 30 (86F)
Maintenance and protection
Regular test
Design of components of the system is to reduce maintenance
cost, but still it is suggested that periodical check may be
carried out.
The cleanliness of control main machine
Main control panel maybe be stained by fingers or covered by
dust after using for a while. Use soft cotton cloth or sponge to
clean it. Don't use any lubricant, liquor such as kerosene, acetone
and strong gel which will damage appearanceand the tran
sparency of top window.
ATTENTION: Don't use any lubricant, liquor such as kerosene,
acetone and strong gel which will damage appearance and the
top transparency of window.
User manual
Limitation of the Products
Limitation of the Products
Although the products is a high standard products, there is also some limitation of them such as false alarm or no alarm, the reasons may be below:
Lack of Maintenance. The system needs maintenance and test regularly test. The sensitive of the detectors may decrease and the siren may not whistle.
Lack of power supply If no power input and the back up power is not enough, the panel can not work normally.
Telephone Line False If the telephone line is cut, the panel could not send alarm signals
Limitation of Smoke Detectors if the smoke is far from the smoke detector, the detector could not alarm
If the intruder break in through some door or window not monitored, or some one knows hot to make the system not work.