Smart temp Apollo 44-800 User manual

Add to my manuals
31 Pages

advertisement

Smart temp Apollo 44-800 User manual | Manualzz

Smart Temp

Apollo

P/n 44-800

User Manual

Version 1.0

TABLE OF CONTENTS

Introduction .........................................................................................................3

Basic Functions ..............................................................................................4, 5

Residential 5-2 Day Programming Mode .......................................................6-3

Setting the clock ...................................................................................................6

Mode selection .....................................................................................................7

Fan selection ........................................................................................................8

Programming 4 daily events ...........................................................................9-12

Factory default schedule ....................................................................................13

Residential 7-Day Programming Mode .....................................................14-22

Setting the clock .................................................................................................14

Mode selection ...................................................................................................15

Fan selection ......................................................................................................16

Programming 2 daily events ........................................................................17-22

1

2

TABLE OF CONTENTS

Commercial Programming Mode ............................................................23-27

Setting the clock .................................................................................................23

Mode selection ...................................................................................................24

Fan selection .....................................................................................................25

Programming 2 events (7-Day or 5-2) ..........................................................26, 27

Commercial default schedule ............................................................................27

Manual Mode .....................................................................................................28

Basic Troubleshooting .....................................................................................29

INTRODUCTION

Your new Smart Temp 44-800 “Apollo” touch screen thermostat has been manufactured using the highest quality components and design currently available. As a result, when properly installed and configured by a professional heating and air conditioning contractor, the 44-800 “Apollo” will provide many years of trouble-free operation.

The 44-800 has been designed to be an attractive, highly reliable and easy-to-use thermostat. By taking time to read and understand this User Manual, you can take advantage of the many features offered in this premium product.

Great care has been taken in the preparation of this manual. Smart Temp Australia P/L takes no responsibility for errors or omissions contained in this document. It is the responsibility of the user to ensure that this thermostat, or equipment connected to it is operating to their respective specifications and in a safe manner.

Due to ongoing product improvements, Smart Temp Australia P/L reserves the right to change the specification of the 44-800 thermostat (or its components) without notice.

All right reserved © Smart Temp Australia Pty Ltd

Intellectual rights apply.

3

BASIC FUNCTIONS

To simplify use, the 44-800 only displays information relevant to the current mode of operation. When adjustments are required, the thermostat will display additional functions.

Time and Day

(only shown in programmable mode)

Touch to set day and time

PM

Heat Set

Set temperature

(displayed or hidden based on thermostat configuration)

Space temperature

(always displayed)

Fan

Touch to select

Automatic or

Always On operation

Day

Program

(only shown in programmable mode)

Heat

Mode

Touch to select

Heat, Cool, Auto,

Off or E. Heat

4

BASIC FUNCTIONS

Some symbols and display functions are normally hidden from view until needed or may not appear based on the thermostat configuration. Make sure your contractor configures the 44-800 to suit your specific needs.

Heat Set

Flt (Filter)

Optional filter reminder alternates with the current time

Clean

Screen

Clean Screen

Touching this button when shown will lock out all thermostat functions for 30 seconds to permit cleaning the display screen

Day

Up and Down Arrows

Used to set temperature, time, day of week and other values

Heat

Locked

Lock

Padlock symbol indicates that the selected function is prohibited or the setpoint limit has been reached

Battery

Shown when battery needs to be replaced

5

6

E

RESIDENTIAL 5-2 DAY PROGRAMMING MODE

Setting the clock

Touch the clock on the display. The day of the week will flash. Use the UP and DOWN arrows to adjust the day. Touch the clock again. The hour will flash. Use the UP and DOWN arrows to adjust the hour. If the time is PM, adjust the hour until the PM symbol appears.

Touch the clock again. The minutes will flash. Use the UP and DOWN arrows to adjust the minutes. Touch the clock again and the thermostat will resume normal operation.

E

RESIDENTIAL 5-2 DAY PROGRAMMING MODE

Mode selection

The 44-800 can control both heating and cooling. Touch the Mode box to cycle through and select available modes. Based on equipment and thermostat configuration, mode selection can be as follows:

PM

Day

Heat Set

Heat

E

Off - Thermostat will not call for heating or cooling.

Heat - Thermostat only controls heating.

When heating system is running, Heat flashes.

Cool - Thermostat only controls cooling.

When cooling system is running, Cool flashes.

Auto - Thermostat controls both heating and cooling. Heat or Cool will flash when equipment is running.

E. Heat - Emergency heat for heat pump systems should the compressor fail.

7

8

RESIDENTIAL 5-2 DAY PROGRAMMING MODE

Fan selection

Touch the Fan box to select Automatic or Always On fan mode. In Automatic mode, the fan operates with a heating or cooling call. If set to Always On, the fan will run continuously.

If the thermostat is turned Off while the fan is set to Always On, the fan will switch to

Automatic mode but can be set back to Always On for constant ventilation when the thermostat is Off.

Heat Set

PM

E

Day

Heat

RESIDENTIAL 5-2 DAYPROGRAMMING MODE

Programming 4 daily events (5-2 schedule)

Touch and hold the Program box until the UP and DOWN arrows along with the flashing days of the week appear. The program format starts with Monday through Friday. You will now be able to program four schedules per day with individual heating and cooling setpoints for all five days of the week. If the Programmable Fan option is ON, you may also program the fan operation for each scheduled event.

Mon Tue Wed Thu Fri

E

9

10

RESIDENTIAL 5-2 DAY PROGRAMMING MODE

Touch the Program box again and the start time for the Morning program will appear and the hour will flash. Use the UP and DOWN arrows to adjust the Morning start time hour.

Touch the Program box again and the minutes will flash. Use the UP and Down arrows to adjust the minutes in 10 minute increments.

Mon Tue Wed Thu Fri

Morning

E

RESIDENTIAL 5-2 DAY PROGRAMMING MODE

Touch the Program box again and the Morning Heat Set temperature will appear and flash.

Use the UP and DOWN arrows to change the heating setpoint.

Mon Tue Wed Thu Fri

Heat Set

Morning

E

11

12

RESIDENTIAL 5-2 DAY PROGRAMMING MODE

Touch the Program box again and the Morning Cool Set temperature will appear and flash.

Use the UP and DOWN arrows to change the cooling setpoint. Repeat the same steps for the Day, Evening and Night programs. After the Night Cool Set temperature is confirmed, touch the Program box again and Saturday and Sunday (Sat Sun) will flash. Repeat the same steps for the Saturday and Sunday programs.

Mon Tue Wed Thu Fri

Cool

Set

Night

E

RESIDENTIAL 5-2 PROGRAMMING MODE

After the Saturday and Sunday Night Cool Set temperature is confirmed or Programmable

Fan (if used), the thermostat will resume normal operation in approximately 20 seconds. All scheduled events will be saved in non-volitile memory.

Residential 5-2 Day Factory Default Schedule

Start Time Set Temperature

Schedule (Mon-Fri) (Sat-Sun) Heating Cooling

Morning 6:00 AM 6:00 AM 21 25

Day 8:00 AM 8:00 AM 16 28

Evening 6:00 PM 6:00 PM 21 25

Night 10:00 PM 10:00 PM

16

28

13

14

E

RESIDENTIAL 7-DAY PROGRAMMING MODE

Setting the clock

Touch the clock on the display. The day of the week will flash. Use the UP and DOWN arrows to adjust the day. Touch the clock again. The hour will flash. Use the UP and DOWN arrows to adjust the hour. If the time is PM, adjust the hour until the PM symbol appears.

Touch the clock again. The minutes will flash. Use the UP and DOWN arrows to adjust the minutes. Touch the clock again and the thermostat will resume normal operation.

E

RESIDENTIAL 7-DAY PROGRAMMING MODE

Mode selection

The 44-800 can control both heating and cooling. Touch the Mode box to cycle through and select available modes. Based on equipment and thermostat configuration, mode selection can be as follows:

Heat Set

PM

Day

Heat

E

Off - Thermostat will not call for heating or cooling.

Heat - Thermostat only controls heating.

When heating system is running, Heat flashes.

Cool - Thermostat only controls cooling.

When cooling system is running, Cool flashes.

Auto - Thermostat controls both heating and cooling. Heat or Cool will flash when equipment is running.

E. Heat - Emergency heat for heat pump systems should the compressor fail.

15

16

RESIDENTIAL 7-DAY PROGRAMMING MODE

Fan selection

Touch the Fan box to select Automatic or Always On fan mode. In Automatic mode, the fan operates with a heating or cooling call. If set to Always On, the fan will run continuously.

If the thermostat is turned Off while the fan is set to Always On, the fan will switch to

Automatic mode but can be set back to Always On for constant ventilation when the thermostat is Off.

Heat Set

PM

E

Day

Heat

RESIDENTIAL 7-DAY PROGRAMMING MODE

Programming 4 daily events (7 individual days)

Touch and hold the Program box until the UP and DOWN arrows along with the flashing days of the week appear. The program format starts with Monday. You will now be able to program four schedules per day with individual heating and cooling setpoints for each day of the week. If the Programmable Fan option is ON, you may also program the fan operation for each scheduled event.

Mon

E

17

18

RESIDENTIAL 7-DAY PROGRAMMING MODE

Touch the Program box again and the start time for the Monday Morning program will appear and the hour will flash. Use the UP and DOWN arrows to adjust the Morning start time hour. Touch the Program box again and the minutes will flash. Use the UP and Down arrows to adjust the minutes in 10 minute increments.

Mon

Morning

E

RESIDENTIAL 7-DAY PROGRAMMING MODE

Touch the Program box again and the Morning Heat Set temperature will appear and flash.

Use the UP and DOWN arrows to change the heating setpoint.

Mon

Heat Set

Morning

E

19

20

RESIDENTIAL 7-DAY PROGRAMMING MODE

Touch the Program box again and the Morning Cool Set temperature will appear and flash.

Use the UP and DOWN arrows to change the cooling setpoint. Repeat the same steps for the Day, Evening and Night programs. After the Night Cool Set temperature is confirmed, touch the Program box again and the copy symbol will appear. If you wish to copy the

Monday schedule to additional days of the week, use the UP and DOWN arrows to select

Mon

E

RESIDENTIAL 7-DAY PROGRAMMING MODE

Mon Tue Wed

E each additional day. For example, you might want to copy the Monday schedule to Tuesday and Wednesday. Once you have selected the days, touch the Program key and the copy symbol will flash confirming that the Monday schedule has been copied to the additional days selected. Touch the Program key again and programming will commence with the next non-scheduled day, which in the example would be Thursday.

21

22

RESIDENTIAL 7-DAY PROGRAMMING MODE

To skip the copy feature and advance to the next day, simply press the Program key after the copy symbol appears. You can program a different schedule for each day of the week.

The factory default schedule is the same as the 5-2 programming mode.

Tue

E

E

COMMERCIAL PROGRAMMING MODE

Setting the clock

Touch the clock on the display. The day of the week will flash. Use the UP and DOWN arrows to adjust the day. Touch the clock again. The hour will flash. Use the UP and DOWN arrows to adjust the hour. If the time is PM, adjust the hour until the PM symbol appears.

Touch the clock again. The minutes will flash. Use the UP and DOWN arrows to adjust the minutes. Touch the clock again and the thermostat will resume normal operation.

E

23

COMMERCIAL PROGRAMMING MODE

Mode selection

The 44-800 can control both heating and cooling. Touch the Mode box to cycle through and select available modes. Based on equipment and thermostat configuration, mode selection can be as follows:

Heat Set

24

PM

Day

Heat

E

Off - Thermostat will not call for heating or cooling.

Heat - Thermostat only controls heating.

When heating system is running, Heat flashes.

Cool - Thermostat only controls cooling.

When cooling system is running, Cool flashes.

Auto - Thermostat controls both heating and cooling. Heat or Cool will flash when equipment is running.

E. Heat - Emergency heat for heat pump systems should the compressor fail.

COMMERCIAL PROGRAMMING MODE

Fan selection

Touch the Fan box to select Automatic or Always On fan mode. In Automatic mode, the fan operates with a heating or cooling call. If set to Always On, the fan will run continuously.

If the thermostat is turned Off while the fan is set to Always On, the fan will switch to

Automatic mode but can be set back to Always On for constant ventilation when the thermostat is Off.

Heat Set

PM

E

Day

Heat

25

E

COMMERCIAL PROGRAMMING MODE

Programming 2 daily events (7 Day or 5-2 Schedule)

Touch and hold the Program box until the UP and DOWN arrows along with the flashing days of the week appear. The program format starts with Monday for 7-Day programming and Monday through Friday for 5-2 programming. You will now be able to program two schedules per day (Day and Night) with individual heating and cooling setpoints for each schedule. If the Programmable Fan option is ON, you may also program the fan operation for each scheduled event.

Mon

26

COMMERCIAL PROGRAMMING MODE

Refer to the programming steps as outlined in the Residential 5-2 or 7-Day programming section. The only difference is that two schedules per day (Day and Night) will be programmed.

Commercial Default Schedule

Start Time Set Temperature

Schedule 7 Days Per Week Heating Cooling

Day 6:00 AM 20 25

Night 10:00 PM 16 28

27

MANUAL MODE

When the 44-800 is configured for manual mode, it provides set point adjustment,

Mode and Fan selection only. The thermostat clock is hidden and no programming is necessary.

Typical Manual Mode Display

Heat Set

Heat

28

TROUBLESHOOTING

Display is blank - Check HVAC circuit breaker and reset if necessary.

- Make sure power switch at HVAC system is on.

- If thermostat is battery powered only, replace batteries.

Heating or cooling - Touch MODE to set system to Heat or Cool. Set the heating does not respond temperature a few degrees above the space temperature or

the cooling temperature a few degrees below the space

temperature. Heat or Cool should flash confirming that the

thermostat is calling.

- The thermostat has a 4 minute equipment time delay for cooling and

heat pump systems. Wait 4 minutes for the system to

restart.

- Contact your installing HVAC contractor if your 44-800 Thermostat does not function as expected.

29

Smart Temp

20/1488 Ferntree Gully Rd Knoxfield Victoria 3180

www.thermostat.com.au

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project