Wel-Bilt G7CE3034X - DIMENSIONS GUIDE Service manual

Add to my manuals
12 Pages

advertisement

Wel-Bilt G7CE3034X - DIMENSIONS GUIDE Service manual | Manualzz

R-370EZ

SUPPLEMENTAL SERVICE MANUAL

S9125R370EPZ/

Popcorn Fresh

Vegetables Rice

Reheat

Sensor

Ground

Meat

Frozen

Vegetables

Chicken

Breast

Frozen

Entree

Veverage

Compu

Defrost

1

6

2

7

3

8

4

9

5

0

Power

Level

Custom

Help

STOP

Clear

Minute Plus

START

MICROWAVE OVEN

MODEL

R-370EZ

In the interest of user-safety the oven should be restored to its original condition and only parts identical to those specified should be used.

WARNING TO SERVICE PERSONNEL: Microwave ovens contain circuitry capable of producing very high voltage and current, contact with following parts may result in a severe, possibly fatal, electrical shock. (High Voltage Capacitor, High

Voltage Power Transformer, Magnetron, High Voltage Rectifier

Assembly, High Voltage Harness etc..)

This is a supplemental Service Manual for Model R-370EZ. This model is quite similar to base model R-370EK. Use this supplemental manual together with the Base Model Service Manual

(Refer No. is S4112R370EPS/) for complete operation, service information, etc..

TABLE OF CONTENTS

Page

PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO

AVOID POSSIBLE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY ................... INSIDE FRONT COVER

BEFORE SERVICING ...................................................................................................... INSIDE FRONT COVER

WARNING TO SERVICE PERSONNEL ................................................................................................................ 1

MICROWAVE MEASUREMENT PROCEDURE ................................................................................................... 2

FOREWORD AND WARNING ............................................................................................................................... 3

PRODUCT DESCRIPTION .................................................................................................................................... 4

OVEN SCHEMATIC ............................................................................................................................................... 4

PARTS LIST .......................................................................................................................................................... 5

SERVICE INFORMATION ..................................................................................................................................... 7

PACKING AND ACCESSORIES ......................................................................................................................... 10

SHARP CORPORATION

11

This document has been published to be used for after sales service only.

The contents are subject to change without notice.

R-370EZ

PRECAUTIONS TO BE OBSERVED BEFORE AND

DURING SERVICING TO AVOID POSSIBLE

EXPOSURE TO EXCESSIVE MICROWAVE

ENERGY

(a) Do not operate or allow the oven to be operated with the door open.

(b) Make the following safety checks on all ovens to be serviced before activating the magnetron or other microwave source, and make repairs as necessary: (1) interlock operation, (2) proper door closing, (3) seal and sealing surfaces (arcing, wear, and other damage), (4) damage to or loosening of hinges and latches, (5) evidence of dropping or abuse.

(c) Before turning on microwave power for any service test or inspection within the microwave generating compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment, integrity, and connections.

(d) Any defective or misadjusted components in the interlock, monitor, door seal, and microwave generation and transmission systems shall be repaired, replaced, or adjusted by procedures described in this manual before the oven is released to the owner.

(e) A microwave leakage check to verify compliance with the Federal Performance Standard should be performed on each oven prior to release to the owner.

BEFORE SERVICING

Before servicing an operative unit, perform a microwave emission check as per the Microwave

Measurement Procedure outlined in this service manual.

If microwave emissions level is in excess of the specified limit, contact SHARP ELECTRONICS

CORPORATION immediately @1-800-237-4277.

If the unit operates with the door open, service person should 1) tell the user not to operate the oven and 2) contact SHARP ELECTRONICS CORPORATION and The Food and Drug Administration's

Center for Devices and Radiological Health immediately.

Service personnel should inform SHARP ELECTRONICS CORPORATION of any certified unit found with emissions in excess of 4mW/cm 2 . The owner of the unit should be instructed not to use the unit until the oven has been brought into compliance.

12

R-370EZ

WARNING TO SERVICE PERSONNEL

Microwave ovens contain circuitry capable of producing very high voltage and current, contact with following parts may result in a severe, possibly fatal, electrical shock.

(Example)

High Voltage Capacitor, High Voltage Power Transformer, Magnetron, High Voltage Rectifier Assembly, High Voltage Harness etc..

Read the Service Manual carefully and follow all instructions.

Don't Touch !

Danger High Voltage

Before Servicing

1. Disconnect the power supply cord remove outer case.

2. Open the door and block it open.

3. Discharge high voltage capacitor.

, and then

WARNING:RISK OF ELECTRIC SHOCK.

DISCHARGE THE HIGH-VOLTAGE

CAPACITOR BEFORE SERVICING.

The high-voltage capacitor remains charged about 60 seconds after the oven has been switched off. Wait for 60 seconds and then short-circuit the connection of the highvoltage capacitor (that is the connecting lead of the highvoltage rectifier) against the chassis with the use of an insulated screwdriver.

Whenever troubleshooting is performed the power supply must be disconnected. It may, in some cases, be necessary to connect the power supply after the outer case has been removed, in this event,

1. Disconnect the power supply cord, and then remove outer case.

2. Open the door and block it open.

3. Discharge high voltage capacitor.

4. Disconnect the leads to the primary of the power transformer.

5. Ensure that the leads remain isolated from other components and oven chassis by using insulation tape.

6. After that procedure, reconnect the power supply cord.

When the testing is completed,

1. Disconnect the power supply cord, and then remove outer case.

2. Open the door and block it open.

3. Discharge high voltage capacitor.

4. Reconnect the leads to the primary of the power transformer.

5. Reinstall the outer case (cabinet).

6. Reconnect the power supply cord after the outer case is installed.

7. Run the oven and check all functions.

After repairing

1. Reconnect all leads removed from components during testing.

2. Reinstall the outer case (cabinet).

3. Reconnect the power supply cord after the outer case is installed.

4. Run the oven and check all functions.

Microwave ovens should not be run empty. To test for the presence of microwave energy within a cavity, place a cup of cold water on the oven turntable, close the door and set the power to HIGH and set the microwave timer for two (2) minutes. When the two minutes has elapsed (timer at zero) carefully check that the water is now hot. If the water remains cold, carry out Before Servicing procedure and reexamine the connections to the component being tested.

When all service work is completed and the oven is fully assembled, the microwave power output should be checked and a microwave leakage test should be carried out.

1

R-370EZ

MICROWAVE MEASUREMENT PROCEDURE

A. Requirements:

1) Microwave leakage limit (Power density limit): The power density of microwave radiation emitted by a microwave oven should not exceed 1mW/cm 2 at any point 5cm or more from the external surface of the oven, measured prior to acquisition by a purchaser, and thereafter (through the useful life of the oven), 5 mW/cm 2 at any point 5cm or more from the external surface of the oven.

2) Safety interlock switches:

Primary interlock relay and door sensing switch shall prevent microwave radiation emission in excess of the requirement as above mentioned, secondary interlock switch shall prevent microwave radiation emission in excess of 5 mW/cm 2 at any point 5cm or more from the external surface of the oven.

B. Preparation for testing:

Before beginning the actual measurement of leakage, proceed as follows:

1) Make sure that the actual instrument is operating normally as specified in its instruction booklet.

Important:

Survey instruments that comply with the requirement for instrumentation as prescribed by the performance standard for microwave ovens, 21 CFR 1030.10(c)(3)(i), must be used for testing.

2) Place the oven tray in the oven cavity.

3) Place the load of 275

±

15 ml (9.8 oz) of tap water initially at 20

±

5˚C (68˚F) in the center of the oven cavity.

The water container shall be a low form of 600 ml (20 oz) beaker with an inside diameter of approx. 8.5 cm (3-1/2 in.) and made of an electrically nonconductive material such as glass or plastic.

The placing of this standard load in the oven is important not only to protect the oven, but also to insure that any leakage is measured accurately.

4) Set the cooking control on Full Power Cooking Mode

5) Close the door and select a cook cycle of several minutes. If the water begins to boil before the survey is completed, replace it with 275 ml of cool water.

C. Leakage test:

Closed-door leakage test (microwave measurement)

1) Grasp the probe of the survey instrument and hold it perpendicular to the gap between the door and the body of the oven.

2) Move the probe slowly, not faster than 1 in./sec. (2.5 cm/sec.) along the gap, watching for the maximum indication on the meter.

3) Check for leakage at the door screen, sheet metal seams and other accessible positions where the continuity of the metal has been breached (eg., around the switches, indicator, and vents).

While testing for leakage around the door pull the door away from the front of the oven as far as is permitted by the closed latch assembly.

4) Measure carefully at the point of highest leakage and make sure that the highest leakage is no greater than 4mW/cm 2 .

NOTE: After servicing, record data on service invoice and microwave leakage report.

2

R-370EZ

SERVICE MANUAL

MICROWAVE OVEN

R-370EZ

FOREWORD

This Manual has been prepared to provide Sharp Electronics Corp. Service Personnel with Operation and Service

Information for the SHARP MICROWAVE OVEN, R-370EZ.

The model R-370EZ is quite similar to base model R-370EK (Refer No. is S4112R370EPS/).

It is recommended that service personnel carefully study the entire text of this manual and the base model's manual so that they will be qualified to render satisfactory customer service.

Check the interlock switches and the door seal carefully. Special attention should be given to avoid electrical shock and microwave radiation hazard.

WARNING

Never operate the oven until the following points are ensured.

(A) The door is tightly closed.

(B) The door brackets and hinges are not defective.

(C) The door packing is not damaged.

(D) The door is not deformed or warped.

(E) There is no other visible damage with the oven.

Servicing and repair work must be carried out only by trained service personnel.

DANGER

Certain initial parts are intentionally not grounded and present a risk of electrical shock only during servicing.

Service personnel - Do not contact the following parts while the appliance is energized;

High Voltage Capacitor, Power Transformer, Magnetron, High Voltage Rectifier Assembly, High Voltage

Harness;

If provided, Vent Hood, Fan assembly, Cooling Fan Motor.

All the parts marked “*” on parts list are used at voltages more than 250V.

Removal of the outer wrap gives access to voltage above 250V.

All the parts marked “

” on parts list may cause undue microwave exposure, by themselves, or when they are damaged, loosened or removed.

SHARP ELECTRONICS CORPORATION

SHARP PLAZA, MAHWAH,

NEW JERSEY 07430-2135

3

R-370EZ

ITEM

Power Requirements

Power Output

Case Dimensions

Cooking Cavity Dimensions

1.4 Cubic Feet

Control Complement

Oven Cavity Light

Safety Standard

SPECIFICATION

DESCRIPTION

120 Volts / 13.5 Amperes

60 Hertz

Single phase, 3 wire grounded

1000 watts (IEC TEST PROCEDURE)

Operating frequency of 2450MHz

Width 17-1/4"

Height 13-3/8"

Depth 18-3/8"

Width 13-3/4"

Height 7-1/4"

Depth 16-1/2"

Touch Control System

Clock ( 1:00 - 12:59 )

Timer (0 - 99 min. 99 seconds)

Microwave Power for Variable Cooking

Repetition Rate;

HIGH ................................................ Full power throughout the cooking time

P-90 .................................................................... approx. 90% of Full Power

P-80 .................................................................... approx. 80% of Full Power

P-70 .................................................................... approx. 70% of Full Power

P-60 .................................................................... approx. 60% of Full Power

P-50 .................................................................... approx. 50% of Full Power

P-40 .................................................................... approx. 40% of Full Power

P-30 .................................................................... approx. 30% of Full Power

P-20 .................................................................... approx. 20% of Full Power

P-10 .................................................................... approx. 10% of Full Power

P-0 .................................................... No power throughout the cooking time

SENSOR COOKING pads , INSTANT ACTION pads

COMPU DEFROST pads, Number selection pads

CUSTOM HELP PAD, POWER LEVEL pad,

KITCHEN TIMER/CLOCK pad

STOP/CLEAR pad, MINUTE PLUS /START pad

Yes

UL Listed FCC Authorized

DHHS Rules, CFR, Title 21, Chapter 1, Subchapter J

SCHEMATIC

NOTE: CONDITION OF OVEN

1. DOOR CLOSED

2. CLOCK APPEARS ON DISPLAY

MONITOR

FUSE 20A

OVEN THERMAL

CUT-OUT

NOTE: " " indicates components with potential above 250V.

AH SENSOR

MG. THERMAL CUT-OUT

POWER

TRANSFORMER

N.O.

F3 F2

SECONDARY

INTERLOCK

RELAY

F1

CONTROL UNIT

CAPACITOR

0.94

µ

F

AC 2200V

120V AC

60 Hz

GRN

N.O.

COM.

B2 B1

OVEN LAMP

RELAY (RY1)

DOOR

SENSING

SWITCH

COM.

OL

OVEN

LAMP

PRIMARY

INTERLOCK

SWITCH

TTM

TURNTABLE

MOTOR

FM

FAN

MOTOR

FM

FAN

MOTOR

Figure O-1. Oven Schematic-Off Condition

4

RECTIFIER

MAGNETRON

R-370EZ

Q21

Q22

R1

R2

R4

R50

R51

R52

R53

R54

RY1

RY2

SP1

T1

VRS1

ZD1

3- 1

3- 1A

3- 1B

3- 1C

C1

C2

C3

C21

C50-51

D1-4

D20-22

D40

IC2

Q1

*

*

*

*

*

1- 1

1- 2

1- 3

1- 4

1- 5

1- 6

1- 7

1- 7

1- 8

1- 9

1-10

1-10

1-11

1-12

1-12

1-13

1-14

PARTS LIST

Note: The parts marked “

” may cause undue microwave exposure.

The parts marked “*” are used in voltage more than 250V.

REF. NO.

PART NO.

DESCRIPTION

ELECTRIC PARTS

FACCDA085WREZ Power supply cord

QFSHDA024WRZZ Fuse holder

QSW-MA137WRE0 Primary interlock switch / door sensing switch

FFS-BA023WRK0 Monitor fuse 20A and monitor switch (AM51620C53Y1) assembly

RTHM-A116WRE0 Thermal cut-out 125 deg. C (MG)

FH-DZA100WRKZ High voltage rectifier assembly

RC-QZA211WRE0 High voltage capacitor

RC-QZA286WRZZ High voltage capacitor (Interchangeable)

RMOTEA400WRZZ Fan motor

RTRN-A638WRZZ Power transformer

RV-MZA288WRE0 Magnetron

RV-MZA308WRZZ Magnetron (Interchangeable)

RLMPTA082WRZZ Oven lamp

RMOTDA186WRE0 Turntable motor

RMOTDA211WRE0 Turntable motor (Interchangeable)

RTHM-A123WRZZ Thermal cut-out 125 deg. C (OVEN)

FDTCTA212WRKZ AH sensor

2- 1

2- 2

2- 3

2- 4

2- 5

CABINET PARTS

GDAI-A335WRWZ Base plate

GLEGPA087WRFZ Front leg

GLEGPA081WRFZ Leg

GCABUA807WRPZ Outer case cabinet

GCOVAA291WRFZ Harness cover

4- 1

4- 2

4- 3

4- 4

4- 5

4- 6

4- 7

4- 8

4- 9

4-10

POWER UNIT PARTS

DPWBFC179WRUZ Power unit

QCNCMA431DRE0 2-pin connector (CN-B)

QCNCMA470DRZZ 9-pin connector (CN-C)

QCNCMA237DRE0 3-pin connector (CN-F)

RC-KZA087DRE0 Capacitor 0.1 uF 50V

VCEAB31VW108M Capacitor 1000 uF 35V

VCEAB31VW106M Capacitor 10 uF 35V

VCEAB31VW106M Capacitor 10 uF 35V

RC-KZA087DRE0 Capacitor 0.1 uF 50V

RH-DZA006PRE0 Diode (1N4002)

VHD1SS270A/-1 Diode (1SS270A)

VHD1SS270A/-1 Diode (1SS270A)

VHIBA4558//-6 IC (BA4558)

VS2SB1238//-3 Transistor (2SB1238)

VSDTD143ES/-3 Transistor (DTD143ES)

VSDTA143ES/1B Transistor (DTA143ES)

VRD-B12EF242J Resistor 2.4k ohm 1/4W

VRS-B13AA331J Resistor 330 ohm 1W

VRD-B12EF332J Resistor 3.3k ohm 1/4W

VRS-B13AA331J Resistor 330 ohm 1W

RR-DZA285DRZZ Resistor 3.32k ohm

±

0.5% 1/4W

RR-DZA286DRZZ Resistor 3.57k ohm

±

0.5% 1/4W

VRN-B12EK182F Resistor 1.8k ohm

±

1.0% 1/4W

VRN-B12EK364F Resistor 360k ohm

±

1.0% 1/4W

RRLY-A076DRE0 Relay (OMIF-S-124LM)

RRLY-A113DRE0 Relay (DU24D1-1P(M)-R)

RALM-A014DRE0 Buzzer (PKM22EPT)

RTRNPA111DRE0 Transformer

RH-VZA032DRE0 Varistor (10G471K)

VHEHZ161///-1 Zener diode (HZ16-1)

OVEN PARTS

PHOK-A118WRFZ Latch hook

LBNDKA099WRW0 Capacitor holder

PDUC-A772WRWZ Fan duct

NFANJA047WREZ Fan blade

PPACGA084WRF0 TTM packing

************* Oven cavity (Not a replaceable part)

GCOVHA423WRFZ Choke cover

LANGQA531WRWZ Lamp angle

PCOVPA361WREZ Waveguide cover

LANG-A084WRFZ Separate angle A

5

Q'TY CODE

2

1

1

1

1

1

1

1

1

1

AV

AX

BP

BK

BL

AL

AQ

AS

AK

AX

AQ

AG

AH

AS

AK

AQ

AV

1

1

1

1

1

2

1

1

1

1

1

1

1

1

1

2

1

1

1

1

1

1

AW

AK

AC

BD

AH

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

3

1

1

1

1

2

4

1

1

1

1

1

1

1

AH

AD

AN

AL

AE

--

AL

AP

AD

AG

AC

AA

AA

AK

AM

AG

AP

AE

AA

AC

AA

AA

AA

AA

AA

AC

AA

AA

AD

AA

AA

AK

AA

BC

AC

AF

AD

AA

AF

AA

R-370EZ

5- 1

5- 2

5- 3

5-3-1

5-3-2

5- 4

5- 5

5- 6

5- 7

5- 8

5- 9

5-10

5-11

5-12

5-13

5-14

5-15

6- 1

6- 2

6- 2

6- 3

6- 4

6- 5

6- 6

6- 7

6- 8

6- 9

7- 1

7- 2

7- 3

7- 4

7- 5

7- 6

7- 7

7- 8

7- 9

7-10

7-11

7-12

7-13

7-14

7-15

7-16

7-17

REF. NO.

4-11

4-12

4-13

4-14

4-15

4-16

4-17

4-18

4-19

4-20

4-21

4-22

4-23

4-24

4-25

4-26

4-27

4-28

4-29

4-30

PART NO.

DESCRIPTION

LANG-A085WRFZ Separate angle B

LANG-A086WRFZ Separate angle C

PCLI-A002WREZ PC support clip

FANG-A013WRYZ Magnetron duct assembly

LANGFA200WRPZ Support angle

NCPL-A053WRFZ Coupling

PCUSUA571WRPZ Cushion

PDUC-A775WRTZ Exhaust duct

PPACGA181WREZ Cushion

PPACGA182WREZ Cushion

PCUSUA573WRPZ Cushion

PCUSUA313WRP0 Cushion

PCUSUA578WRPZ Cushion

PCUSUA577WRPZ Cushion

PCUSGA561WREZ Cushion

PCUSUA583WRPZ Cushion

PCUSUA375WRP0 Cushion

PCUSGA560WREZ Cushion

PCUSGA564WREZ Cushion

PCUSGA563WREZ Cushion

DOOR PARTS

FDORFA347WRTZ Door panel

PSHEPA775WREZ Sealer film

FWAKPA352WRKZ Door frame assembly

FUNTKB060WREZ Key unit

HPNL-A762WRRZ Door screen

LSTPPA193WRFZ Latch head

MSPRTA202WREZ Latch spring

DPWBFC176WRKZ CPU unit

LHLD-A236WRFZ LCD holder

PSHEPA786WREZ LED sheet

FW-VZA272DREZ 9-pin wire harness

PCOVPA372WRWZ PWB cover

PCUSUA567WRPZ Cushion

XEBSD38P08000 Screw : 3.8mm x 8mm

XEPSD30P08XS0 Screw : 3mm x 8mm

LHLD-A237WRFZ Light guide

PCUSUA461WRP0 Cushion

MISCELLANEOUS

FROLPA079WRK0 Turntable support

NTNT-A079WRF0 Turntable tray

NTNT-A084WRE0 Turntable tray (Interchangeable)

FW-VZB827WREZ Main wire harness

QW-QZA242WRZZ High voltage wire B

TCAUAA265WRRZ DHHS caution label

TCAUAA254WRR0 Monitor caution label

TINSEA914WRRZ Instruction book

FW-VZB828WREZ Switch harness

FW-VZB802WREZ T.T. motor harness

SCREWS,NUTS AND WASHERS

XHPSD40P08K00 Screw : 4mm x 8mm

XHPSD40P08000 Screw : 4mm x 8mm

XOTSD40P08000 Screw : 4mm x 8mm

LX-CZA073WRE0 Special screw

XOTSD40P12000 Screw : 4mm x 12mm

XHPSD30P08XS0 Screw : 3mm x 8mm

XHTSD40P08RV0 Screw : 4mm x 8mm

LX-CZA070WRE0 Special screw (Torx tamper proof screw)

LX-CZ0052WRE0 Special screw

XHPSD30P06000 Screw : 3mm x 6mm

XHTSD40P08000 Screw : 4mm x 8mm

XHTSD40P12RV0 Screw : 4mm x 12mm

XOTSD40P12RV0 Screw : 4mm x 12mm

XOTSF40P08000 Screw : 4mm x 8mm

LX-EZA060WREZ Special screw

XOTSD40P12000 Screw : 4mm x 12mm

XHBWW30P08000 Screw : 3mm x 8mm

6

1

1

1

1

1

1

1

1

1

1

1

1

1

4

1

1

1

3

1

1

1

1

1

1

1

1

1

1

4

1

2

9

2

2

8

1

9

1

2

4

2

4

1

2

Q'TY CODE

1

1

1

1

1

1

1

1

1

1

2

1

1

1

2

1

1

1

1

1

AE

AH

AP

AH

AC

AC

AF

AG

AG

AG

AD

AP

AD

AC

AC

AG

AH

AB

AH

AH

AF

AC

AC

AM

AK

AF

AP

AR

AQ

AW

BD

AC

BB

AL

AF

AE

AA

AX

AH

BE

AV

AU

AE

AD

AA

AL

AB

AB

AA

AC

AA

AA

AA

AA

AA

AA

AA

AC

AA

AA

AA

AA

AA

AB

HOW TO ORDER REPLACEMENT PARTS

To have your order filled promptly and correctly, please furnish the following information.

1. MODEL NUMBER

2. REF. NO.

3. PART NO.

4. DESCRIPTION

Order Parts from the authorized SHARP parts Distributor for your area.

Defective parts requiring return should be returned as indicated in the Service Policy.

R-370EZ

SERVICE INFORMATION

The color of lead wire has been changed as follow.

MODEL

R-370EK

R-370ES

R-370EZ

EFFECTIVE FROM

Serial No. from 26937

Serial No. from 04928

1 st. lot production

POWER SUPPLY

CORD 120V 60Hz

NOTE:

The grounding conductor of the power supply cord has been grounded by power supply cord fixing screw.

The screw must always be kept tight.

N H

NOTE:

The neutral (WHT) wire must be connected to the terminal with "N" mark on the power supply cord.

WHT

BLK

POWER

TRANSFORMER

GRY

WHT

BLK

ORG from Aug. 2001 Prod. from Aug. 2001 Prod. ORG

T1

SECONDARY

INTERLOCK

RELAY RY2

COM.

N.O.

BLK

RED

RED

RED

GRY

RY1

COM.

N.O.

POWER UNIT

WHT

BLK

MONITOR

FUSE

&

HOLDER

BLK

7

FAN

MOTOR

GRY

WHT

RED

RED

R-370EZ

1 2

OVEN AND CABINET PARTS

3 4 5

7-3

6

4-17

2-4

A

7-4

7-17

1-14

4-28 7-14

A

4-18

7-8

B

4-28

4-25

4-26

6-6

1-13

1-1

4-24

4-27

7-14

7-12

4-19

C

6-5

7-13

7-7

7-11

4-6

4-21

1-9

7-11

4-23

D

E

F

2-5

4-9

4-16

7-5

2-2

7-5

4-20

6-2

4-30

4-5

1-12

7-9

7-1

7-7

4-15

4-8

7-11

4-1

1-11

7-15

4-22

4-29

7-1

1-4 7-7

7-2

7-3

4-11

7-1 x2

1-2

1-3

1-8

4-3

4-4

7-1 x2

7-7

4-4

1-5

7-3

4-14

7-7

1-10

7-10

1-3

1-8

7-6

1-4

3-1

4-10

4-13 x2

7-3

7-1

1-6

G

4-12

1-7

7-7

4-2

B

C

D

E

F

G

2-1

7-13

6-1

7-3

H H

1 2 3 4 5

7-16

6

2-3

8

1 2 3 4 5

DOOR PARTS

A

B

C

5-3

5-7

5-9

5-13

5-11

5-10

5-6

5-14

5-6

5-8

5-1

5-13

5-3-1

5-12

5-2

5-12

5-12

4-7

5-12

D

E

F

G

H

1

6

R-370EZ

A

B

C

D

2

5-3-2

5-15

MISCELLANEOUS

5-5

5-4

6-8 6-3

6-4

6-9

Actual wire harness may be different from illustration.

E

F

(CAPACITOR)

G

H

3 4 5 6

9

R-370EZ

PACKING AND ACCESSORIES

DOOR PROTECTION SHEET

SPADPA204WRE0

INTO THE

OVEN CAVITY

FOAM SHEET

SPAKHA017WREZ

6-7 INSTRUCTION BOOK

& PRINTING MATTER

6- 2 TURNTABLE TRAY

6- 1 TURNTABLE SUPPORT

TRAY PAD

SPADFA499WREZ

Not replaceable items.

TOP PAD ASSEMBLY

FPADBA451WRKZ

WRAP COVER

SSAKHA072WREZ

CABINET COVER

SPAKHA018WREZ

BOTTOM PAD ASSEMBLY

FPADBA453WRKZ

PACKING CASE

FPAK-A412WRKZ

COPYRIGHT © 2001 BY SHARP CORPORATION

ALL RIGHTS RESERVED.

No part of this publication may be reproduced, stored in retrieval systems, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission of the publisher.

10

2001 SHARP CORP. (8S1.700E) Printed in U.S.A

advertisement

Was this manual useful for you? Yes No
Thank you for your participation!

* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project

Related manuals