Preparation (continued) / Vorbereitung (Fortsetzung) Installation Instructions / Installationsanleitung Example 2: 3x8 socket strip Beispiel 2: 3x8 Steckdosenleiste ► Attach the PDU adapter to the rear side of the ► Befestigen Sie den PDU-Adapter am hinteren rail and fasten ist with an M4x5,5 countersunk screw (see circle). RMK-PDU 2U horizontal Rack shelf kit 1U / Rack 19” Ablageboden 1U RMK-PDU 3U horizontal PRIMECENTER M1 19-inch symmetrical Rack* ► Fasten the 3x8 socket strip with an M4x10 TT2 screw to front of the rail and with an M5x10 cylinder head screw to the PDU adapter on the rear side of the rail . i ► Identify the right and the left rail (see label on A26361-F2735-Z690-1-7619 the rail). Overview / Übersicht ► Position the right rail in the rear right support upright by inserting the retaining bolt . ► Clamp the right rail between the front right sup- port upright and the rear right support upright by pressing it together , positioning it on the front support upright and releasing it again. The rail automatically adjusts to the rack depth. ► Swivel the rail in the vertical position . ► Fasten the rail to the front right support upright with two M5 centering screws . RMK-PDU 2U horizontal (for mounting of all socket strips except 32 A singlephase 5-way socket strips) (für die Montage aller Steckdosenleisten außer einphasigen 32 A 5-fach-Steckdosenleisten) Rack shelf kit 1U (regularly mounted) Ablageboden 1U (regulär eingebaut) Rack shelf kit 1U (mounted rotated horizontally through 180 degrees as cable tray) Ablageboden 1U (horizontal um 180° gedreht als Kabelwanne eingebaut) Cable bracket 2U dummy panel 7x Cable ties 2x PDU adapters for 3x8 socket strips i Installationsanweisungen für weitere Steckdosenleisten finden Sie im Handbuch „PRIMECENTER M1 19inch Rack User Manual“. ► Fasten the rail to the rear right support upright with one M5 centering screw . ► Repeat this procedure to install the left rail. ► Bestimmen Sie die rechte und die linke Schiene (siehe Aufkleber auf der Schiene). ► Positionieren Sie die rechte Schiene am rechten hinteren Montageholm, indem Sie den Haltebolzen einsetzen . ► Spannen Sie die rechte Schiene zwischen dem rechten vorderen Montageholm und rechten hinteren Montageholm, indem Sie die Schiene zusammendrücken , am vorderen Holm positionieren und sie wieder freilassen. Die Schiene passt sich automatisch an die Racktiefe an. ► Schwenken Sie die Schiene in die vertikale Position . ► Befestigen Sie die Schiene am vorderen rechten Montageholm mit zwei M5 Zentrierschrauben . ► Befestigen Sie die Schiene am hinteren rechten Montageholm mit einer M5 Zentrierschraube . ► Wiederholen Sie diesen Vorgang, um die linke Schiene zu befestigen. Right and left rail (see label on the rail) 3x8 Steckdosenleiste mit einer M4x10 TT2 Schraube am vorderen Ende der Trageschiene und mit einer M5x10 Zylinderkopfschraube am PDU-Adapter am hinteren Ende der Trageschiene . Delivery Contents / Verpackungsinhalt RMK-PDU 3U horizontal (RMK-PDU 2U horizontal + Rack shelf kit 1U for mounting 32 A single-phase 5-way socket strips and other socket strips) (RMK-PDU 2U horizontal + Rack 19“ Ablageboden 1U für den Einbau von einphasigen 32 A 5-fachSteckdosenleisten und anderer Steckdosenleisten) RMK-PDU 2U horizontal ► Befestigen Sie die Mounting the rail systems / Schienensysteme montieren *A26361-F2735-Z690-1-7619* English / Deutsch For installation instructions about other socket strips, please refer to the „PRIMECENTER M1 19-inch Rack User Manual“. Ende der Trageschiene mit einer M4x5,5 Senkkopfschraube (siehe Kreis). Screw kit: 4x M5x10 centering screw 14x M5x10 cylinder head screw 6x M5x12 centering screw 10x M5 screw nut 12x M5 washer 2x M4x5,5 countersunk screw Mounting cable bracket / Kabelhalter montieren Rechte und linke Schiene (siehe Aufkleber auf der Schiene) Kabelhalter Before installing the carrier rails in the rack you must mount the socket strips to the carrier rails. Example 1: 16 A single-phase 10-way socket strip ► Fasten the socket strip to the carrier rail with two M5x10 cylinder head screws and M5 screw nuts (see circles). the carrier rails with two M5x10 cylinder head screws (see circles). ► Befestigen Sie den Kabelhalter an den hinteren Enden der Trageschienen mit zwei M5x10 Zylinderkopfschrauben (siehe Kreise). 2U Blindblende 7x Kabelbinder 2x PDU Adapter für 3x8 Steckdosenleisten Schraubensatz: 4x M5x10 Zentrierschrauben 14x M5x10 Zylinderkopfschrauben 6x M5x12 Zentrierschrauben 10x M5 Muttern 12x M5 Unterlegscheiben 2x M4x5,5 Senkkopfschrauben Preparation / Vorbereitung i ► Fasten the cable bracket to the rear sides of ► Fasten the power cables to the bracket with cable ties (example, see arrows). ► Befestigen Sie die Kabel am Kabelhalter mit Kabelbindern (Beispiel, siehe Pfeile). Completion / Fertigstellung i Vor der Installation der Trageschienen im Rack müssen Sie die Steckdosenleisten an den Trageschienen befestigen. Beispiel 1: 16 A einphasige 10-fach Steckerleiste ► Attach the 2U dummy panel in front of the carrier rails. It is installed in the same way as the 1U dummy panel, see back page. ► Bringen Sie die 2U Blindblende vor den Tra- geschienen an. Die Montage erfolgt auf die gleiche Weise wie bei der 1U Blindblende, siehe Rückseite. ► Befestigen Sie die Steckerleiste mit zwei M5x10 Zylinderkopfschrauben und M5 Muttern an den Trageschienen (siehe Kreise). * Installation in asymmetrical PRIMECENTER racks is also supported. For details please refer to the „PRIMECENTER M1 19-inch Rack User Manual“. Der Einbau in asymmetrische PRIMECENTER Racks wird unterstützt. Weitere Informationen finden Sie im Handbuch „PRIMECENTER M1 19-inch Rack User Manual“. Online documentation for 3rd party rack installation can be found on / Online-Dokumentation für den Einbau in 3rd-Party Racks finden Sie unter / http://manuals.ts.fujitsu.com/index.php?id=5406-5605-5606 Rack shelf kit 1U / Rack 19” Ablageboden 1U RMK-PDU 3U horizontal Delivery Contents / Verpackungsinhalt 1x Rack shelf 1U 1x Ablageboden 1U Right and left rail (see label on the rail) Rechte und linke Schiene (siehe Aufkleber auf der Schiene) Screw kit: 4x M5x10 centering screw 4x M4x10 screw with washers 1x 1U dummy panel (Combination of RMK-PDU 2U horizontal and Rack shelf kit 1U / Komination aus RMK-PDU 2U horizontal und Rack 19“ Ablageboden 1U) Overview / Übersicht Schraubensatz: 4x M5x10 Zentrierschraube 4x M4x10 Schrauben mit Unterlegscheiben The RMK-PDU 3U horizontal is provided for the installation of 32 A single-phase 5-way socket strips. It consists of the RMK-PDU 2U horizontal and the Rack shelf kit 1U. 1x 1U Blindblende Figure left shows an installed RMK-PDU 3U horizontal with a 32 A single-phase 5-way socket strip and a 3x8 socket strip. Mounting the carrier rails / Trageschienen montieren ► Identify the right and the left rail (see label on ► Position the right rail in the rear right support upright by inserting the retaining bolts . ► Clamp the right rail between the front right support upright and the rear right support upright by pressing it together, positioning it on the front support upright and releasing it again. The rail automatically adjusts to the rack depth . ► Bestimmen Sie die rechte und die linke Schie- ► Fasten the right rail to the front right support upright with an M5 centering screw . ► Repeat this procedure to install the left rail. ► Positionieren Sie die rechte Schiene am dem rechten vorderen Montageholm und rechten hinteren Montageholm, indem Sie die Schiene zusammendrücken, am vorderen Holm positionieren und sie wieder freilassen. Die Schiene passt sich automatisch an die Racktiefe an . ► Befestigen Sie die rechte Trageschiene am ► Install the rack shelf kit 1U rotated horizontally through 180 degrees as cable tray. ► Fasten the 32 A single-phase 5-way socket strip to the carrier rail of the RMK-PDU 2U horizontal with two M5x10 cylinder ead screws, see arrows. ► Install the carrier rails in the rack above the rack Mounting the rack shelf / Ablageboden einbauen ► Fasten the rack shelf to the carrier rails with four M4x10 screws with washers (see arrows). Rack shelf kit 1U (regularly mounted) Ablageboden 1U (regulär eingebaut) shelf. i Bauen Sie den Ablageboden nach Möglichkeit vor der Installation von Servern ins Rack. Ca. 5 HEs oberund unterhalb des Ablagebodens sollten bei der Montage frei sein. ► Setzen Sie den Ablageboden auf die Trage- schienen. ► Befestigen Sie den Ablageboden an den Trageschienen mit 4 M4x10 Schrauben mit Unterlegscheibchen (siehe Pfeile). Rack shelf kit 1U (mounted rotated horizontally through 180 degrees as cable tray) Ablageboden 1U (horizontal um 180° gedreht als Kabelwanne eingebaut) Installing the dummy panel / Blindblende anbringen Installing the 1U dummy panel Installation der 1U Blindblende ► Hook the latch hook of the dummy panel in the ► Haken Sie den Rasthaken der Blindblende im right support upright. ► Lock the dummy panel on the left side with the plastic spring. The 2U dummy panel is installed in the same way. Installieren Sie zuerst den Rack 19“ Ablageboden 1U und anschließend das RMK-PDU 2U horizontal. Mounting the RMK-PDU 3U horizontal / RMK-PDU 3U horizontal einbauen Trageschiene zu montieren. ► Place the rack shelf on the carrier rails. i ► Spannen Sie die rechte Schiene zwischen ► Wiederholen Sie diesen Vorgang, um die linke If possible, mount the rack shelf to the rack before installing servers. When installing the rack shelf, about 5 HUs above and below should be free. Bild links zeigt ein installiertes RMK-PDU 3U horizontal mit einer einphasigen 32 A 5-fach-Steckdosenleiste und einer 3x8 Steckdosenleiste. rechten hinteren Montageholm, indem Sie die Haltebolzen einsetzen . vorderen rechten Montageholm mit einer M5 Zentrierschraube . i First, install the Rack shelf kit 1U, and then the RMK-PDU 2U horizontal. ne (siehe Aufkleber auf der Schiene). the rail). i Das RMK-PDU 3U horizontal ist für die Installation von einphasigen 32 A 5-fachSteckdosenleisten vorgesehen. Es besteht aus dem RMK-PDU 2U horizontal und dem Rack 19“ Ablageboden 1U. rechten Rackholm ein. ► Verriegeln Sie die Blindblende auf der linken Seite mit der Plastikfeder . Die 2U Blindblende wird auf die gleiche Weise installiert. Fastening the 32 A single-phase 5-way socket strip / 32 A 5-fach-Steckdosenleiste (einphasig) befestigen um 180° gedreht als Kabelwanne im Rack. ► Befestigen Sie die einphasige 32 A 5-fach- Steckdosenleiste an den Trageschienen des RMK-PDU 2U horizontal. ► Bauen Sie die Trageschienen des RMK-PDU 2U horizontal über der Kabelwanne in das Rack. ► Befestigen Sie den Kabelträger an den Trage- ► Fasten the cable bracket to the carrier rails of the RMK-PDU 2U. ► Fasten the power cable to the cable bracket. ► Attach the dummy panel 1U in front of the rack shelf and the dummy panel 2U in front of the RMK-DU 2U carrier rails. i ► Installieren Sie den Ablageboden 1U horizontal For maintenance purposes (e. g. access to the PDU fuses), you can remove the dummy panel 2U for a short time. schienen des RMK-PDU 2U. ► Befestigen Sie das Stromkabel der Blade-PDU am Kabelträger. ► Bringen Sie die Blindblende 1U vor der Kabel- wanne und die Blindblende 2U vor den Trageschienen des RMK-PDU 2U an. i Für Maintenance-Zwecke (z. B. Zugang zu den PDU-Sicherungen) können Sie die Blindblende 2U kurzfristig entfernen.
advertisement
* Your assessment is very important for improving the workof artificial intelligence, which forms the content of this project