INSTALLATION INSTRUCTIONS
BUILT-IN RECTANGULAR FOOD WARMERS
MODELS HSW-6 (D)
ELECTRICAL
MODEL
VOLTS
WATTS
AMPS
PHASE
FIELD
WIRING
GAUGE
TEMP.
RATING
HSW-6
HSW-6D
120
120
825
825
6.9
6.9
SINGLE
SINGLE
14 AWB Cu
14 AWB Cu
90°C
90°C
CUTOUT DETAILS
INCHES
(MM)
PRODUCT DIMENSIONS
9 5/8
(244)
13 3/8
(340)
11 7/8
(302)
5
(127)
4 1/2
(114)
4 7/8
(124)
10 7/8
(276)
TOP CUTOUT
FRONT PANEL CUTOUT
4 1/4
(108)
11 5/8
(295)
13 7/8
(352)
CLEARANCES
7 3/16
(183)
MINIMUM CLEARANCE REQUIRED FROM
UNIT TO THE NEAREST SURFACE
BACK
SIDE
BOTTOM
FRONT
1
2
6 3/4
4 1/2
(25)
(51)
(171)
(114)
INSTALLATION INSTRUCTIONS
INSTALLER MUST MEET CONDITIONS OF ACCEPTABILITY
OUTLINED BELOW UPON INSTALLATION:
10 11/32
(263)
12 17/32
(318)
1/2 IN NPT
DRAIN ON
HSW-6D MODEL
WARMER FLANGE
GASKET
1. Required installation clearances:
Wooden and Metal Installation: DO NOT install closer than
4 1/2 inches to front wall, 1 inch to back, 2 inches to
side wall, and 6 3/4 inches to surface below the unit.
2. Unit shall be accessible for servicing from the bottom.
3. If storage is to be used underneath the unit, it is
recommended that a baffle be placed 8 1/2 inches below
the unit to avoid contact with elevated temperatures.
WELLSLOK
SCREWDRIVER
TO FABRICATE:
1. Layout cutout dimensions on countertop and front apron,
shown in cutout details above.
2. Cut and/or drill holes as required in countertop and
apron.
3. Must be accessible for servicing from the bottom.
TO INSTALL:
IMPORTANT - DO NOT disconnect lead wires from the Master
Control Panel when making installation.
1. Locate warmer and control over the counter cutout. Pass
the control box through the opening, then mount the control
box to the rear of the apron.
2. Apply a bead of silicone adhesive/sealant to the gasket
on the underside of the warmer flange, then seat warmer
onto the countertop. Properly position.
3. From underneath, insert screwdriver into "slots" on the
wellslok frame and twist "ears" outward to secure flange
tightly to countertop (see detail).
4. Mount control box to apron cutout as shown in drawing.
5. Mount control panel onto electrical box using the screws
supplied.
WELLS/BLOOMFIELD * VERDI, NV
COUNTERTOP
MASTER
CONTROL
PANEL
IMPORTANT:
MOUNT APPLIANCE SO THAT THE
CONTROL PANEL IS LOCATED TO
THE FRONT OF THE FIXTURE.
40740-1 REV (-)